HomeMy WebLinkAbout3820 PIO PICO DR; ; FA160033; Permit9/27/22, 11:19 AM FA160033 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 3820 PlO PICO DR Permit Type: FALARM Parcel No: Lot #: 0 Reference No.: Permit No: FA160033 Status: ISSUED Applied 6/6/2016 Approved: 6/23/2016 Issued: 6/23/2016 PC #: Inspector: Project Title: ST. PATRICK PARISH SCHOOL NEW FULLY AUTOMATIC VOICE FA SYSTEM FOR BLDG M & ADMIN & EXPAND UPON FIRST PHASE W/ FULLY AUTOMATIC VOICE FA SYSTEM TO SERVE CLASSROOM BLDG. POWER LIMITED ADDRESSABEL FA SYSTEM W/ VOICE EVAC, OPEN PLENUM CABLE (SPLIN) & CONDUIT (POLYLINE) CIRCUITS-INITIATING: ADDRESSABLE, CLASS B NOTIFICATION: CLASS B, STYLE Y Applicant: LOW VOLTAGE FIRE INC STE L 1930 WATSON WY VISTA CA 760-598-4110 Owner: Fees ($) ' Add'l Fees ($) Total ($) Balance ($) 518 0 518 0 about:blank 1/1 FIRE ALARM SYSTEM SUBMITTAL Lci wàItczge I ntgrt systm S FIRE ALARM • SOUND • DATA • MEDIA • SECURITYS CCTV S ACCESS CONTROL ST. PATRICK PARISH SCHOOL PHASE II 3820 PlO PICO DRIVE, S CARLSBAD, CA 92008 CITY PROECT #152088 LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1930 WATSON WAY, STE L VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: CIO, C16 # 791832 FAl 60033 3820 PlO PICO DR PHONE: (760) 598-4110 FAX: (760) 598-4107 LowV'oltage integrated system PART DESCRIPTION MANUFACTURER CSFM LISTING NFS2-640 FIRE ALARM CONTROL PANEL NOTIFIER 7165-0028:0224 UDACT-2 UNIVERSAL DIGITAL ALARM COMMUNICATOR TRANSMITTER NOTIFIER 7165-0028.0224 DVC-EM DIGITAL VOICE CONTROL BOARD NOTIFIER 7165-0028:0224 DVC-KD KEYPAD VOICE CONTROL NOTIFIER 7165-0028:0224 DS-DB DIGITAL DISTRIBUTION BOARD NOTIFIER 7165-0028:0224 DS-AMP AMPLIFIER,125 WATTS NOTIFIER 7165-0028:0224 CELLCOMSLCF CELL DIALER DMP 7300-1157:0136 SPSCW SPEAKER STROBE © CEILING SYSTEM SENSOR 7320-1653:0201 SPSWK OUTDOOR SPEAKER STROBE @WALL SYSTEM SENSOR 7320-1653:0201 SPWK OUTDOOR SPEAKER @ WALL SYSTEM SENSOR 7320-1653:0201 SPWK OUTDOOR SPEAKER @ WALL SYSTEM SENSOR 7320-1653:0201 SPCW SPEAKER @ CEILING SYSTEM SENSOR 7320-1653:0201 SCW STROBE @ CEILING SYSTEM SENSOR 7125:1653:0186 SWK OUTDOOR STROBE @ WALL SYSTEM SENSOR 7300-1653:0187 FSP-851 SMOKE DETECTOR NOTIFIER 7272:0028:0206 FST-851 HEAT DETECTOR NOTIFIER 7270:0028:0196 B21OLP SMOKE/ HEAT BASE SYSTEM SENSOR 7300-1653:0109 302-ET-165 OUTDOOR HEAT DETECTOR NOTIFIER 7270-0021:0001 FMM-101 MINI MONITOR MODULE NOTIFIER 7300-0028:0219 FDM-1 DUAL MONITOR MODULE NOTIFIER 7300-0028:0219 FMM-1 MONITOR MODULE NOTIFIER 7300-0028:0219 FRM-1 RELAY MODULE NOTIFIER 7300-0028:0219 DNR DUCT DETECTOR(BY OTHERS) SYSTEM SENSOR j 3242-1653:0209 RTS-151 REMOTE TEST SWITCH SYSTEM SENSOR 1 7300-1653:0212 I Low Voltage Integrated Systems, Inc. 1930 Watson Way, Ste L • Vista, California 92081 FIRE • SECURITY • CCTV • ACCESS CONTROL • SOUND • MEDIA LICENSE NO. C10, C16 #791832 email: info @ sdlvis.com N FS2-640 ElA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column printers). History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. Alarm Verification selection per point, with automatic counter. Presignal/Positive Alarm Sequence (PAS). Silence inhibit and Auto Silence timer options. March time/temporal/California two-stage coding/strobe synchronization. Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate. Full QWERTY keypad. Battery charger supports 18 - 200 AH batteries. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Automatic time control functions, with holiday exceptions. Surface Mount Technology (SMT) electronics. Extensive, built-in transient protection. Powerful Boolean logic equations. Support for SCS Series smoke control system in HVAC mode. DN-7111:I •A-13 NFS2-640(E) NOTI Fl ER® Intelligent Addressable Fire Alarm System by Honeywell General The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series prod- ucts meet virtually every application requirement. The NFS2-640's modular design makes system planning eas- ier. The panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. A host of other options are available, including single- or multi- channel voice; firefighter's telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection prod- ucts for challenging environments, and many additional options. NOTE: Unless called out with a version-specific "E" at the end of the part number, "NFS2-640" refers to models NFS2-640 and NFS2-640E; similarly, "CPU2-640" refers to models CPU2-640 and CPU2-640E. Features Certified for seismic applications when used with the appro- priate seismic mounting kit. Approved for Marine applications when used with listed compatible equipment. See DN-60688. One, expandable to two, isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7. Up to 159 detectors (any mix of ion, photo, thermal, or multi-sensor) and 159 modules (Addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay) per SLC. 318 devices per loop/636 per FACP or network node. Standard 80-character display, 640-character large display (NCA-2), or display-less (a node on a network). Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-3205YS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging. 6.0 A switch mode power supply with four Class A/B built-in Notification Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online or offline programming utility. Upload! Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. Autoprogramming and Walk Test reports. Multiple central station communication options: - Standard UDACT . - Internet - Internet/GSM 80-character remote annunciators (up to 32). [1 DN-7111:I.12/20/2013—Page 1of8 NCA-2 AS PRIMARY D!sPMv Backlit, 640-character display. Supports SCS Series smoke control system in FSCS mode when SCS is connected to the NCA-2 used as primary display. Supports DVC digital audio loop. Printer and CRT EIA-232 ports. EIA-485 annunciator and terminal mode ports. Alarm, Trouble, Supervisory, and Security relays. FLASHS CA N® INTELLIGENT FEATURES Polls up to 318 devices in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment — up to nine levels. Pre-alarm ONYX intelligent sensing - up to nine levels. Day/Night automatic sensitivity adjustment. Sensitivity windows: - Ion - 0.5 to 2.50/./foot obscuration. - Photo - 0.5 to 2.35%/foot obscuration. - Laser (VIEW®) - 0.02 to 2.00/o/foot obscuration. - Acclimate PlusTM - 0.5 to 4.0%/foot obscuration. - lntelliQuadTM - 1.0 to 4.0%/foot obscuration. - lntelliQuadTM PLUS - 1.0 to 4.0%/foot obscuration Drift compensation (U.S. Patent 5,764,142). Degraded mode — in the unlikely event that the CPU2-640 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAG circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. FSL-751 (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the fire location. Early warning performance comparable to the best aspira- tion systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. Low-temperature warning signal at 40°F ± 5°F (4.44°C ± 2.77°C). SLC Intelligent Loop 1 Up to 32 remote displays FDU-80 LCD2-80 FSC-851 IntelliQuad FAPT-851 Acclimate PLUS FSL-751 FlashScan VIEW FSP-851 Photo FSI-851 Ion FST-851 Thermal FSA-8000 etc. NBG-12LX I 4 XP6I10 I/O Modules FMM-1 I FCM-1 IDC , NAC FRM-1 Relay Contact SLC Intelligent Loop 2 2048 annunciator/control !J .MPM ACM-8R ACM/AEM-24AT LDM-32 Relay Control LED Annunciator Custom Graphics Dual phone lines to Central Station : KDM-R2 display OR NCA-2 OR with no display EIA-485 EIA-485 Optional 636-point UDACT Sample System Options NFS2-640 "C" cabinet size shown PRN Series Printer 711 bIok.2O13.wml is Page 2 of 8— DN-71 11:1' 12/20/2013 FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. FSA -8000 INTELLIGENT FAAST DETECTOR Connects directly to the SLC loop of compatible ONYX series panels Provides five event thresholds that can be individually pro- grammed with descriptive labels for control-by-event pro- gramming; uses five detector addresses. Uses patented particle separator and field-replaceable filter to remove contaminants. • Advanced algorithms reject common nuisance conditions FCO-851 INTELLIQUADTM PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4 (CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). Low-pressure CO2 listed. DIGITAL VOICE AND TELEPHONE FEATURES Up to eight channels of digital audio. 35, 50, 75, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series; NCA-2 required as primary display). Solid-state digital message generation. Firefighter telephone option. 30- to 120-watt high-efficiency amplifiers (AA Series). Backup tone generator and amplifier option. NFS2-640 can also integrate with the FirstCommand Emer- gency Communications System. See DN-60772. HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPLY (6.0 A IN ALARM) 120 VAC (NFS2-640); 240 VAC (NFS2-640E). Displays battery current/voltage on panel (with display). FlashScan, Exclusive World-Leading Detector Protocol At the heart of the NFS2-640 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashS- can is an all-digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS2-640 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS2-640 with industry-leading smoke detection capabil- ity. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high-speed microcomputer used by the NFS2-640. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control func- tions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature. The FACP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installa- tion, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS2-640, like all NOTIFIER intelligent panels, has the exclusive feature of pro- gram creation and editing capability from the front panel key- pad, while continuing to provide fire protection. The architecture of the NFS2-640 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per-point segments, while the NFS2-640 simulta- neously monitors other (already installed) points for alarm con- ditions. VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Win- dows®-based and provides technologically advanced capabili- ties to aid the installer. The installer may create the entire program for the NFS2-640 in the comfort of the office, test it, DN-711 1:1 • 12/20/2013 - Page 3 of 8 store a backup file, then bring it to the site and download from a laptop into the panel. Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS2-640's flexible sys- tem design. Rows: The first row of equipment in the cabinet mounts in the chassis shipped with the FACP. Mount the second, third, or fourth rows of equipment in a CHS-4 series chassis or, for Dig- ital Voice Command products, in CA-1 or CA-2. (For DVC-EM and DAA2/DAX components see DVC Manual; for DS series components see DS-AMP Manual; for DVC-AO applications, see AA Series Installation Manual). Other options are avail- able; see your panel's installation manual. Wiring: When designing the cabinet layout, consider separa- tion of power-limited and non-power-limited wiring as dis- cussed in the NFS2-640 Installation Manual. Positions: A chassis offers four basic side-by-side positions for components; the number of modules that can be mounted in each position depends on the chassis model and the size of the individual module. There are a variety of standoffs and hardware items available for different combinations and config- urations of components. It is critical that all mounting holes of the NFS2-640 are secured with a screw or standoff to ensure continuity of Earth Ground. Layers: The control panel's chassis accepts four layers of equipment, including the control panel. The CPU2-640 fills three positions (left to right) in the first-installed layer (the back of the chassis); its integral power supply occupies the center two positions in the next two layers; the optional display occu- pies (the left) two positions at the front, flush with the door. Some equipment, such as the NCA-2, may be mounted in the dress pinel directly in front of the control panel. The NCA-2 can be used as a primary display for the NFS2-640 (use NCA/ 640-2-KIT) by directly connecting their network ports (required inCanadian stand-alone applications); see NCA-2 data sheet for mounting options (DN-7047). Expansion: Installing an LEM-320 Loop Expander Module adds a second SLC loop to the control panel. The LEM-320 is mounted onto the CPU2-640, occupying the middle-right, sec- ond (back) slot on the chassis. Networking: If networking two or more control panels, each unit requires a Network Communication Module or High- Speed Network Communication Module. (HS-NCM can sup- port two nodes; see "Networking Options" on page 5). These modules can be installed in any option board position (see manual), and additional option boards can be mounted in front of the network communication modules. KDM-R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout, see figure). 12 LED indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled; Control Active; Abort; Pre-Discharge; Discharge. Keypad Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED backlight. Product Line Information "Configuration Guidelines" on page 4 "Networking Options" on page 5 "Auxiliary Power Supplies and Batteries" on page 5 "Audio Options" on page 5 "Compatible Devices, ElA-232 Ports" on page 5 "Compatible Devices, EIA-485 Ports" on page 5 "Compatible Intelligent Devices" on page 6 "Enclosures, Chassis, and Dress Plates" on page 6 "Other Options" on page 7 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On systems with one FACP (one CPU2-640/-640E), display options are the KDM-R2 or the NCA-2. On network systems (two or more networked fire panel nodes), at least one NCA-2, NCS, or ONYX Works annunciation device is required. Other options listed as follows; KDM-R2: 80-character backlit LCD display with QWERTY pro- gramming and control keypad. Order two BMP-1 blank mod- ules and DP-D15P2 mounting plate separately. Requires top row of a cabinet. Required for each stand-alone 80-character display system. The KDM-R2 may mount in network nodes to display 'local" node information as long as at least one NCA-2 or NCS/ONYX Works network display is on the system to dis- play network information. (Non-English versions also available: KDM-R2-FR, KDM-R2-PO, KDM-R2-SP.) NCA-2: Network Control Annunciator, 640 characters. On sin- gle CPU2-640/-640E systems, the optional NCA-2 can be used as the Primary Display for the panel and connects directly to the CPU2-640/-640E. On network systems (two or more networked fire panel nodes), one network display (either NCA-2 or NCS/ONYX Works) is required for every system. On network systems, the NCA-2 connects to (and requires) a standard Network Communication Module or High-Speed Net- work Communication Module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP-D15P2, ADP-4B, or in an annunciator box, such as the ABS-2D. In CAB-4 top-row applications, a DP-DISP2 and two BMP-1 blank modules are required for mounting. Required for NFS2-640 applications employing the DVC-EM with DAL devices. Non-English versions are available. For marine appli- cations, order NCA-2-M; for non-English Marine applications, order NCA-2-M and the appropriate KP-KIT-XX. See DN-7047. CPU2-640: Central processing unit (CPU) with integral 3.0 A (6.0 A in alarm) power supply for an NFS2-640 system. Includes control panel factory-mounted on a chassis; one Sig- naling Line Circuit expandable to two; documentation kit. Order one per system or as necessary (up to 103 network nodes) on a network system. (Non-English versions also avail- able: CPU2-640-FR, CPU2-640-PO, CPU2-640-SP) CPU2-640E: Same as CPU2-640 but requires 240 VAC, 1.5 A, (3.0 A in alarm). (Non-English versions also available: CPU2- 640E-PO, CPU2-640E-SP) NCA/640-2-KIT: Bracket installation kit required to mount NCA-2 to the CPU2-640/-640E's standard chassis. DP-DISP2: Dress panel for top row in cabinet with CPU2-640/ 640E installed. ADP2-640: Dress panel for middle rows with CPU2-640/640E. BMP-1: Blank module for unused module positions. BP2-4: Battery plate, required. LEM-320: Loop Expander Module. Expands each NFS2-640 to two Signaling Line Circuits. See DN-6881. C Page 4 of 8— DN-71 11:1 • 12/20/2013 S NETWORKING OPTIONS NCM-W, NCM-F: Standard Network Communications Mod- ules. Wire and multi-mode fiber versions available. See DN- 686 1. HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed Network Communications Modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conver- sion models are available. See DN-60454. RPT-W, APT-F, APT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN- 6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part num- bers. NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN- GW-EM.) See DN-60499. NWS-3: NOTI.FIRE.NETTM Web Server. See DN-6928. CAP-GW: Common Alerting Protocol Gateway. See DN- 605 76. VESDA-HLI-GW: VESDAnet high-level interface gateway. See DN-60753. LEDSIGN-GIN: UL-listed sign gateway. Interfaces with classic and high-speed NOTl•FlRE•NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See DN-60679. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 A or 10.0 A addressable charging power sup- ply. See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. FCPS-24S61S8: Remote 6 A and 8 A power supplies with bat- tery charger. See DN-6927. BAT Series: Batteries. NFS2-640 uses two 12 volt, 18 to 200 AH batteries. See DN-6933. AUDIO OPTIONS, NOTE: For mounting hardware, see "Enclosures, Chassis, and Dress Plates" on page 6 and peripheral data sheets. DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. Capable of playing up to eight simultaneous messages when used with Digital Audio Loop (DAL) devices. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display. See DN- 60726. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC-EM while retaining digital audio distribuition capabilities. Can be configured with up to four DS- AMPs, supplying high-level risers spread throughout an instal- lation. See DN-60565. DVC-KD: DVC-EM keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons. See DN- 7045. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC-EM, DS-DB distribution board, and DAX and DAA2 Series amplifiers. See DN-60633. DVC-AO: DVC Analog Output board provides four analog out- put circuits for use with AA Series amplifiers. Four-channel operation supported. See DN-7045. DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- bly with power supply; includes chassis. See DN-60556. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. TELH-1: Firefighter's Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis. See DN-7045. CMIC-1: Optional microphone and microphone well assembly used with the CA-1 chassis. RM-1/RM-1SA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-iSA) stand-alone cabinets. See DN-6 728. AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier and audio input supervision, backup input, and automatic swi- tchover, power supply, cables. See DN-3224. AA-120/AA-100: Audio Amplifier provides up to 120 watts of 25 VRMS audio power for the NFS-640. The amplifier contains an integral chassis for mounting to a CAB-134, -C4, or -D4 backbox (consumes one row). Switch-mode power. Includes audio input and amplified output supervision, backup input, and automatic switchover to backup tone. Order the AA-100 for 70.7 VRMS systems and 100 watts of power. See DN-3224. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC-EM systems running SR4.0. For specific information on DAA-50 series amplifiers, refer to DN-7046. For information on DAA-7525 Series, refer to DN-60257. NFC-25150: 25 watt, 25 VRMS, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, digital message generator, and single-/dual-channel Class A or Class B speaker circuits. See DN-60772. COMPATIBLE DEVICES, EIA -232 PORTS PRN-6: 80-column printer. See DN-6956. VS4095/5: Printer, 40-column, 24V. Mounted in external back- box. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals. See DN-6870. COMPATIBLE DEvIcES, EIA -485 PORTS ACM-24AT: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. DN-71 11:1 • 12/20/2013 - Page 5 of 8 ACM-48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs can be programmed (by powered-up switch selec- tion) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See DN-6862. ACM-8111: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. FDU-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-6820. LCD2-80: Terminal and ACS mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-60548. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM- R32; remote custom graphic driver modules. See DN-0551. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS-8L, SCE-8L; eight (expandable to 16) circuits (HVAC only). See DN-4818. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (single-address-style) or in CHS2-M2 position. See DN-6860. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides pos- itive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). Up to 256 programmable codes. Mounts in BB-UZC or other compatible chassis (pur- chased separately). See DN-3404. COMPATIBLE INTELLIGENT DEVICES FSA-8000: Intelligent FAAST Fire Alarm Aspiration Sensing Technology®. Intelligent aspirating smoke detector. For Cana- dian applications, order FSA-8000A. See DN-60792. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-200S: Intelligent beam smoke detector with integral sen- sitivity test. See DN-6985. FSC-851: FlashScan lntelliQuad Advanced Multi-Criteria Detector. See DN-604 12. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite- ria Fire/CO Detector. See DN-60689. FSl-851: Low-profile FlashScan ionization detector. See DN- 6934. FSP-851: Low-profile FlashScan photoelectric detector. See DN-6935. FSP-851T: FSP-851 plus dual electronic thermistors that add 135°F (57°C) fixed-temperature thermal sensing. See DN- 6935. FSP-851R: FSP-851, remote-test capable. For use with DNR(W). See DN-6935. FST-851: FlashScan thermal detector 135°F (57°C). See DN- 6936. FST-851R: FlashScan thermal detector 135°F (57°C) with rate-of-rise. See DN-6936. FST-851H: FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. FAPT-851: FlashScan Acclimate Plus low-profile multi-sensor detector. See DN-6937. FSL-751: FlashScan VIEW laser photo detector. See DN- 6886. DNR: InnovairFIex low-flow non-relay duct-detector housing (order FSP-851 A separately). Replaces FSD-751 PL/FSD- 751 RPL. See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. B22461: Isolator base for low-profile detectors. See DN- 60054. B21OLP: Low-profile base. Standard U.S. style. Replaces B71OLP. See DN-60054. B501: European-style, 4 (10.16 cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. B200SCOA: Based on B200SA, with added CO detector markings in English/French. For Canadian applications only. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. FMM-1: FlashScan monitor module. See DN-6 720.. FDM-1: FlashScan dual monitor module. See DN-6 720.. FZM-1: FlashScan two-wire detector monitor module. See DN- 6720.. FMM-101: FlashScan miniature monitor module. See DN- 6720. FTM-1: Firephone Telephone Module connects a remote fire- fighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is supervised. See DN-6989. FCM-1: FlashScan control module. See DN-6 720.. FCM-1-REL: FlashScan releasing control module. See ON- 60390. FIRMA: FlashScan relay module. See DN-6 720.. FDRM-1: FlashScan dual monitor/dual relay module. See ON- 60709. NBG-12LX: Manual pull station, addressable. See DN-6 726.. ISO-X: Isolator module. See DN-2243. See DN-2243. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See DN-6926. XP10-M: FlashScan ten-input monitor module. See DN-6923. SLC-IM: SLC integration module, for VESDAnet detectors. See DN-60755. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-4 Series Enclosure: NFS2-640 mounts in a standard CAB-4 Series enclosure (available in four sizes, "A" through "D"). Backbox and door ordered seperately; requires BP2-4 battery plate. A trim ring option is available for semi-flush mounting. See DN-6857. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabinets are available in three sizes, "B" through "D". See ON- 60229.. Page 6of8-DN-7111:I. 12/20/2013 CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see DN-60688. CHS-4: Chassis for mounting up to four APS-6Rs. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers or one AMG-E and one AA-30. D113-1113: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. NFS-11BB: Battery Box (required for batteries larger than 26 AH). NFS-LBBR: Same as above but red. CHS-BH1: Battery chassis; holds two 12.0 AH batteries. Mounts one the left side of DAA2 chassis. See DN-7046. Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC-EM and a DVC-KD (optional); and the right side houses a CMIC-1 microphone and its well (optional). See DN-7045. Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC-EM mounted on a half-chassis and one NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMlC-i microphone. ADDR Series doors with two-tier visibility are available for use with the CA-2 config- uration: ADDR-134, ADDR-C4, ADDR-D4 (below). CFFT-1: Chassis to mount firefighter's telephone and one ACS annunciator in a CAB-4 row. Includes TELH-1 firefighter's handset for the DVC-EM, chassis, phone well and mounting hardware. Order DP-CFFT dress panel separately. DP-CFFT: CFFT-i dress panel. Requires BMP-1 if no ACS annunciator is installed. ADDR134*: Two-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-134. See DN-7045, DN-6857. ADDR-CV: Three-tier-sized door, designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045, DN-6857. ADDRD4*: Four-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-7045, DN-6857. *Use ADDR-B4/C4/D4 when CA-2 chassis is installed in top two rows with NCA-2 or BP-CA2. Use standard door when CA- 2 is not installed in top two rows. For additional configuration information, see the DVC application guide on http://esd.noti- fier.com. DPA-1: Dress panel, used with the CA-1 chassis when config- ured with a DVC-EM, DVC-KD, and CMIC-1. See DN-7045. DPA-2113: Dress panel used with CA-2 chassis assembly. VP-2B: Dress panel, required when CA-2 chassis is installed in the top two cabinet rows. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMlC-1 is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. See DN- 7045. 0 BP-CA2: Blank plate for CA-2 chassis. BB-UZC: Backbox for housing the UZC-256 in applications where the UZC-256 will not fit in panel enclosure. Black; for red, order BB-UZC-R. SEISKIT-CAB: Seismic mounting kit. Required for seismic- certified applications with NFS2-640 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two 26 AH batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 411UDAC: Digital alarm communicator. See DN-6746. IPDACT-2121,1111), IPDACT Internet Monitoring Module: Con- nects to primary and secondary DACT telephone output ports for Internet communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IR See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: Y-adapter option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red. For Black order IPENC-B. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tor. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. For Canadian applications order IPGSM-4GC. See DH-60769. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. System Specifications SYSTEM CAPACITY Intelligent Signaling Line Circuits ............1 expandable to 2 Intelligent detectors .........................................159 per loop Addressable monitor/control modules..............159 per loop Programmable software zones.........................................99 Special programming zones ............................................. i4 LCD annunciators per CPU2-640/-640E and NCA-2 (observe power).............................................32 ACS annunciators per CPU2-640/-640E ..........................32 addresses x 64 points ACS annunciators per NCA-2 .................................. 32 addresses x 64 or 96 points NOTE: The NCA-2 supports up to 96 annunciator address points per ACM-24AT/-48A. ELECTRICAL SPECIFICATIONS Primary input power: - CPU2-640 board: 120 VAC, 50/60 Hz, 5.0 A. - CPU2-640E board: 220/240 VAC, 50/60 Hz, 2.5 A. Current draw (standby/alarm): - CPU2-640(E) board: 0.250 A. Add 0.035 A for each NAC in use. - KDM-R2: 0.100 A. - LEM-320: 0.100 A. DN-71 11:1 • 12/20/2013 - Page 7 of 8 Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 A. of available power. This is shared by all internal circuits. See Installation Manual for a complete current draw calculation sheet. Standard notification circuits (4): 1.5 A each. Resettable regulated 24V power: 1.25 A. Two non-resettable regulated 24V power outputs: —1.25 A. - 0.50 A. Non-resettable 5V power: 0.15 A. Battery charger range: 18 AH —200 AH. Use separate cab- inet for batteries over 26 AH. Float rate: 27.6 V. CABINET SPECIFICATIONS Systems can be installed in CAB-4 Series cabinets (four sizes with various door options, see DN-6857). Requires BP2-4 Battery Plate. SHIPPING WEIGHT CPU2-640/-640: 14.3 lb (6.49 kg). CPU2-640/-640E: 14.55 lb (6.60 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic NFS2-640 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S635. ULC Listed: S635. FM Approved. MEA: 128-07-E. FDNY: COA#6085, #6121. CSFM: 7165-0028:0243. City of Chicago. City and County of Denver. CCCF listed. Marine Applications: Marine approved systems must be con- figured using components itemized in this document. (See Main System Components, in "Product Line Information.) Spe- cific connections and requirements for those components are described in the installation document, PN 54756. When these requirements are followed, systems are approved by the fol- lowing agencies: US Coast Guard 161.002/50/0, 161.002/55/0 (Standard 46 CFR and 161.002). Lloyds Register 11/600013 (ENV 3 category). American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. STANDARDS The NFS2-640 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: UL 864, 9th Edition (Fire). UL 1076 (Burglary). UL 2572 (Mass Notification Systems). LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual and Waterflow). Not applicable for FM. EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- work). IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- mic). CBC 2007 (Seismic). NOTI•FIRE•NETTM, IntelliQuadTM, and ONYXWorksTM are trademarks; and Acclimate® PIusTM, FirstCommand®, FlashScan®, NOTIFIER®, ONYX®, VeriFire®, and VIEW® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. IBM® is a registered trademark of IBM Corporation. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I So 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. BlNEING & MANDMC1II11INC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 8of8—DN-7111:l. 12/20/2013 10 DN-6933:D • E-205 BAT Series Batteries NOT Fl ER® Sealed Lead-Acid by Honeywell :. General BAT Series Batteries are Power-Sonic brand batteries. BAT Series (or Power-Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features Provide secondary power for control panels. Sealed and maintenance-free. Overcharge protected. Easy handling with leak-proof construction. Ruggedly constructed, high-impact case (ABS). Long service life. Compact design. Agency Listings and Approvals The listings and approvals below apply to BAT Series Batter- ies. In some cases, certain modules may not be listed by cer- tain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Recognized Components: MH20845 (Power-Sonic) 6933c0vjp9 Ordering Information BAT-1250-BP: 10-unit bulk pack of BAT-1250 (12 V 5 AH). BAT-1270-BP: 5-unit bulk pack of BAT-1270 (12 V 7 AH). BAT-12120-BP: 4-unit bulk pack of BAT-12120 (12V 12 AH). BAT-12180-BP: 2-unit bulk pack of BAT-12180 (12 V 18 AH). BAT-12260-BP: 2-unit bulk pack of BAT-12260 (12 V 26 AH). BAT-12550: single battery (12 V 55 AH). BAT-121000: single battery (12 V 100 AH). Part Number Reference & Specifications Part Number Power- Sonic Part Number Battery Description DIMENSIONS Nominal Voltage ______ Nominal Capacity @20hr. rate A.H. Width Depth Height Height over terminal Weight in. mm in. mm in. mm in. mm lb. kg. BAT-1 250 PS-1250 12 5 sealed 3.54 90 2.76 70 3.98 Tr4.21 17 3.50 1.59 BAT-1 270 PS-1270 12 7 sealed 595 151 256 65 3.7 94 386 98 4.8 2.18 BAT-12120 PS-12120 12 12 sealed 595 151 j 386 98 3.7 94 194 100 7.92 3.59 BAT-12180 PS-12180 12 18 sealed 7.13 181 300 76 659 167 659 167 12 5.72 BAT-12260 PS-12260 12 26 sealed 65 167 697 177 4.92 125 492 125 17 7.71 BAT-12550 PS-12550 12 55 sealed 904 230 5.45 138 8.15 207 I&F228 36 1633 BAT-11 210001 PS-121000 1 12 100 1 sealed 112 305 66 168 8.15 207 18.98 1228 68 1 30.84 DN-6933:D • 02/28/2013 - Page 1 of 2 Discharge Characteristic Curves at 20°C (68°F) For 6V For 12V Battery Battery 6.5 13.0 6.0 12.0 2 5.5 11.0 5.0 10.0 E 4.5 9.0 4.0 8.0 C~ J 3C) —I-- - t 2 4 6 810 20 40 60 2 4 6 810 20 Minutes ci Hours Discharge Time Effect of Temperature on Capacity 120 110 80 60 40 a (5 20 0 40 -30 -20 -10 0 10 20 30 40 50 60 Temperature (°C) 0.05 C 0.10 C 0.25 C 0.50 C JL- PS-121000 Shelf-Life and Storage 00 Z—Chaiging is not necessary untes 100%ofcapacTh _\ - - - -.... is required. - 5°C Charging before (41 - - F) fi use is necessary II to help recover 60 - .f 2 full capacifo. - - - - - - I fichargentayfa' ii torestorefall II capacity. Do not - 40°C - 36'C - - 20°C I 40 - - (104°F). _(86°F) let batteriesreac - - .(68°F)..+....... I I I this state. 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) PS-121000 Discharge Characteristics 14.0 13.0 1.2 2.4 6 12 24 36481 2 4 6810 2040 mn -h Discharge Time NOTIFIER® is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. 02013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IlNG &MANFACTIIRINC All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6933:D • 02/28/2013 !1.ui•u !!iUI1iIiI- IIIIUIIi! IIIUIIi!iIIIU1 iiui•uiiuu .ultll-uui..uII.l DN-60686:A1 UDACT-2 NOTIFIER® Universal Digital Alarm (0 Communicator Transmitter by Honeywell General The Universal Digital Alarm Communicator Transmitter (UDACT- 2) is designed for use on Notifier Fire Alarm Control Panels and on the NCA-2 Network Control Annunciator. When used in con- junction with the NCA-2 network control annunciator, the UDACT-2 can report the status of all control panels on NOTI.FIRE.NETTM. The UDACT-2 transmits system status to UL listed Central Station Receivers via the public switched tele- phone network. The UDACT-2 can be installed in the panel cab- inet or remotely in a separate enclosure. NOTE: The UDACT-2 can also be used with legacy panels. Please refer to the UDACT-2 manual for more information. The UDACT-2 upload/download programming and firmware updates are accomplished with VeriFire Tools. Refer to the Pro- gramming Section for further details. The UDACT-2 is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT-2 is capable of transmitting all of the zone and point sta- tus associated with each panel. When the UDACT-2 is used with the NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Report- ing may be in the form of points or zones (refer to the UDACT-2 manual for specific reporting parameters). Points transmitted may be programmed for a variety of types, including fire, water- flow, supervisory, etc. NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features Programmable with VeriFire Tools version 6.60 or higher, allowing the UDACT-2 programming to be uploaded/down- loaded and saved. Maximum of 14 point trouble messages transmitted per hour. Dual phone lines with line voltage detect. Compact in size: 6.75 x 4.25' (17.145 x 10.795 cm). USB port for upload/download programming. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1B/R). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. - Independent zone trouble. - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Off-Normal. - 12 or 24 hour test signal. - Abnormal Test Signal per new UL requirements. - ElA-485 Communication Bus Failure. Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- soff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications.. U DACT-2 Open Collector relay driver for Total Communications Failure or UDACT-2 trouble. Real-time clock. Extensive transient protection. EIA-485 interface to host panel. Programming The UDACT-2 programming is created and downloaded using VeriFire Tools. This enables the unit to be programmed prior to installation, be easily modified, and saved either online or offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- work annunciator. The point report consists of the central station point address, ACS point, ACS point function, panel label, panel point, type code, custom and extended label, alarm verification, walktest participation, presignal, and PAS information. The zone report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label and panel label. This report may be sent to the Central Station for their records. VeriFire Tools also supports upgrading the UDACT-2 operating firmware. DN-60686:A1 • 4/2/12 - Page 1 of 2 Communication Formats Ademco Contact ID 4+2 Standard SIA NOTE: Ademco Contact ID must be used for independent zone reporting. Type Mode Feature Ademco Contact ID format - only Use Type Mode to identify reports to Central Station as: Fire Alarm Burglary Supervisory 24 hour Non-Burglary Pull Station High Temperature Heat Detector Low Temperature Waterfiow Low Water Pressure Duct Detector Low Water Level Flame Sensor Pump Failure Smoke Zone Electrical Specifications Standby current: 40 mA. Current while communicating: 75 mA. Maximum current while communicating and with open collector output activated: 100 mA. Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listed: S635 FM Approved CSFM: 7165-0028:0243 (NFS2-640/320), 7165-0028:0224 (NFS2-3030) FDNY: COA#6085, COA#6098 Ordering Information UDACT-2: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions, and mounting hardware. MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). ABS-SRB: Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP. 9.94° H x 4.63" W x 2.50° D (cm: 25.248 H x 11.760 W x 6.350 D). UBS-113: Metal enclosure with solid door, Black. UBS-1BR: Metal enclosure with solid door, Red. R-10E: SPDT Form-C relay. Contacts rated for 10 A © 115 VAC. Connects to open collector relay driver. R-20E: DPDT Two Form-C relays. Contacts rated for 10A © 115 VAC. Connects to open collector relay driver. FBD-1: Ferrite bead kit. Use for remote mounting only. UL Listed Receivers The chart below shows UL listed receivers compatible with the UDACT-2. A check in the protocol column indicates the receiver supports that protocol. Receiver 4+2 Standard 1800/2300 Ademco Contact ID SIA Ademco 685 (1) Ademco MX8000 (2) v' V Silent Knight 9500 (3) v' V Silent Knight 9800 (4) V V V FBI CP220FB (5) V V V Osborne Hoffman 2000E (6) V V Radionics 6600 (7) v' V SurGard MLR2 (8) V SurGard System III (9) v' V SurGard MLR-2000 (10) v' With 685-8 Line Card with Rev 4.4d software With 124060V206B and 124063 Line Card Rev B With version V2.4 Receiver & 126047 Line Card Rev G With 124077V2.00 Receiver &126047 Line Card Rev M With software V3.9 With V.7301 Receiver S/W With 01.01.03 Receiver S,W & Line Card 01.01.03 With software V1.86 With sotware V1.72 With DSP4016 and V1.6 Line Card NOTl.FlRE.NET is a trademark and Notifierr is a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. IMM in a 13= We cannot cover all specific applications or anticipate all requirements. 131GINEMING & MNUFAiURlNI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60686:A1 • 4/2/12 DN-7045:G • C-7 DVC Series NOTIFIER® Digital Voice Command (a DVC-EM by Honeywell 4 General The DVC is the heart of an integrated, full-featured Audio Command Center. The DVC Digital Voice Command combines the capabilities of a powerful digital audio processor, an event- driven audio message generator, and a router. Designed for use with Digital Audio Loop (DAL) devices such as DAA2, DAX and DAA series digital amplifiers as well as the DS-DB, each DVC supports a dedicated audio network with up to eight channels of audio, five channels of firefighter telephone com- munications, and control and supervision for up to 32 DAL devices. The DVC has two wire digital audio ports to connect to wire DAL segments. Either or both ports may be converted to multi-mode fiber or single-mode fiber using fiber option modules. Larger audio systems incorporating hundreds of amplifiers can be created by networking additional DVC units via NOTI• FIRE •NET. The DVC may be networked with ONYX® Series panels via NOTI•FIRE•NET with an NCA-2, or with an NFS2-3030 (running in network monitor mode). A DVC can be connected directly with a single NFS2-640 or NFS2-3030 Fire Alarm Con- trol Panel (FACP) to create a standalone integrated audio solu- tion as well. Refer to the DVC manual for details. When used as an Audio Command Center with Emergency Paging capability, the optional DVC-KD Keypad Display is required. NOTE: Unless otherwise noted, the term "DVC" refers to the DVC- EM. Features Programmable from NUP port using VeriFire® Tools. Up to 32 minutes of standard quality or 4 minutes of high quality digital audio storage of user-selected/created mes- sages and tones. Supports twisted-pair wire media. Sup- ports single- and multi-mode fiber-optic media when used with fiber option modules. 4-channel analog audio supported with optional DVC-AO Up to 1000 audio sequences. Message prioritization. Equations support flexible programming for distribution of messages. Electrically isolated digital audio ports for direct connection with up to 32 Digital Audio Loop (DAL) devices. Style 4 or 7 configurations supported. Optional DS-RFM, DS-FM, and DS-SFM fiber modules may be used to convert one or both Digital Audio Ports for oper- ation with single-mode or multi-mode fiber. DCC (Display and Control Center) capabilities when used with optional DVC-KD. Firefighters' Telephone Communications to local FFT riser on DVC, 32 local DAL device FFT risers, and FFT communication to additional command stations via NOTI • FIRE• NET. Local paging microphone option. Remote microphone options. Broad All-Call functionality when used with DVC-KD (DVC- Keyboard Display): All Call, Page Active Evac Areas, Page Active Alert Areas, Page Inactive Areas. DVC Shown using CA-2 mounting option, SBB-C4, and ADDR.C4 door. Auxiliary input for 12 Vp.p analog low-level audio sources. Includes user audio level adjustment feature. Auxiliary input accepts external audio sources such as tele- phone paging or background music. High impedance input accepts 600 ohm, line level, 1.0 VRMS, or 1.41 Vp.p low level audio. Selectable AGC, user control of audio level, and audio supervision are supported. Associated NCA-2, or NFS2-3030 (programmed for net- work monitor mode) supports NOTI•FIRE•NET applica- tions. Multiple audio command centers supported via NOTI• FIRE• NET. Distribution of one channel of standard-level paging audio on NOTI•FIRE NET. Three standalone, non-network mode options: - NFS2-3030 (NUP to NUP) digital and analog. - NFS2-640 (NUP to NUP) analog audio only. - NFS2-640 with NCA-2 (NUP to NUP to NUP) digital and analog. Push-to-talk relay, or logic argument. Isolated alarm bus input, to be used for backup activation of alarm messages in the event network communication is lost. Installation Options The DVC provides flexible configurations based on one-row or two-row chassis options that mount into size "B", "C", or "D" CAB-4 Series cabinets. The CA-2 supports a DVC, paging microphone, optional FFT telephone, and mounting location for an NCA-2 or NFS2- 3030D CPU. The ADDR audio door series can be used when a CA-2 is mounted in the top two rows. The CA-1 supports a DN-7045:G.O1/16/2012—Page 1of4 DVC and an optional microphone in a single row. For firefight- ers' telephone applications with a CA-1, the CFFT-i can be mounted in the row below the CA-11. NOTE: For NFS2-640/DVC applications using DAL devices, an NCA-2 is required to annunciate DAL device events. Refer to the DVC System Audio Product Application Guide (part number M-AG-DVC) for more details on DVC applica- tions). Specifications 24 VDC power (TB1): 24 VDC, 1.0 A, non-resettable, power-limited by the source. Recommended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted-pair. Digital audio ports, wire media, A and B (TB2, TB3): Maximum distance per segment is 1900 feet (579.12 m) on Belden 5320UJ (18 AWG, TP) FPL cable: 18 AWG (0.821 mm2) twisted-pair, foil-shielded, power-limited. Consult wir- ing documentation provided in document P/N 52916ADD:C Addendum to DVC and DAA Manuals. Digital audio ports, single- and multi-mode fiber-optic media: DS-FM and DS-SFM fiber option module (no direct DAA connection): Maximum attenuation is 6.5dB for multimode with 50/125 micrometer cable © 1310 nm; 10dB for multi-mode with 62.5/125 micrometer cable © 1310 nm; 30dB for single-mode with 9/125 micrometer cable © 1310 nm. DS-SFM: attenuation for single-mode fiber DAA con- nection* Maximum attenuation: - 17dB for single-mode with 9/125 micrometer cable at 1310 nm going from the DS-SFM to the fiber DAA. —4dB for single-mode with 9/125 micrometer cable going from the fiber DAA to the DS-SFM. Minimum attenua- tion: 12dB going from the DS-SFM to the fiber DAA. Minimum attenuation: —2 dB going from the DS-SFM to the fiber DAA. DS-RFM: attenuation for multi-mode fiber DAA con- nection* Attenuation going from the fiber DAA to the DS-RFM: —2dB maximum for multi-mode with 50/125 micrometer cable © 850 nm for the DS-RFM. - 4dB maximum for multi-mode with 62/5/125 micrometer cable © 850 nm for the DS-RFM. Attenuation going from the fiber DS-RFM to the fiber DAA: - 12dB minimum, 16dB for both cable types. (If the length of the fiber run results in an attenuation of less than 12dB, a suitable attenuator must be used.) * ST® Style connection required at DAA end. Auxiliary input A (AUX A, TB4): Signal strength from low- level analog audio input: maximum 1.0 VRMS, or 1.41 Vp-p. Optional supervision is selectable through programming. Recommended wiring: 18 AWG (0.821 mm2) twisted-pair; max. 14 AWG (2.08 mm2). Auxiliary input must be in the same room as the DVC. Auxiliary input B (AUX B, TB14): Signal strength from low-level analog audio input: 12 Vp-p nominal, 15 Vp-p maxi- mum. Optional supervision is selected through program- ming. Recommended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted-pair. Remote microphone interface (TB9): Recommended wir- ing: 14 to 18 AWG (2.08 to 0.821 mm2) twisted-pair. Power- limited. Maximum distance between remote microphone and DVC: 1000 feet (300 m). Push-to-talk interface (TB10): Dry contact. Recom- mended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted- pair. Alarm bus (TB12): Power-limited by source. Recom- mended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted- pair. FFT riser (TB13): Power-limited output. Class A (Style Z) or Class B (Style Y) operation. Style Y two-wire connections require a 3.9K ohm, 1/2 watt resistor (P/N K-3.9K). Maxi- mum wiring resistance (including individual telephone zone to last handset) permitted is 50 ohms, 10,000 feet (3048 m) maximum wiring distance at 12 AWG (3.31 mm2) to last handset. Optional DVC-AO analog audio output circuits (TB5, TB6, TB7, and TB8): Supervised, power-limited outputs. Signal strength: +12 Vp.p nominal, +15 Vp-p maximum. Rec- ommended wiring: 18 AWG (0.821 mm2) twisted-pair; max. 14 AWG (2.08 mm2). Maximum impedance: 66 ohms. Standards and Codes The Digital Voice Command DVC and DVC-EM comply with the following standards: NFPA 72 2002 National Fire Alarm Code. Underwriters Laboratories Standard UL 864, 9th edition. Underwriters Laboratories of Canada (ULC) ULC-S527-99 Standard of Control Units for Fire Alarm Systems. Listings and Approvals The listings and approvals below apply to the DVC and DVC- EM Digital Voice Command. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635. ULC Listed: S635. FM Approved. CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). FDNY: COA#6065 (NFS2-3030): COA#6085 (NFS2-640). City of Chicago approved: High Rise, Class 1, Class 2 (NFS2-3030, NFS27640, NCA-2). City of Denver approved (NFS2-3030). PSB Corporation approved (Singapore) (NFS2-3030). Product Line Information DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. Supports twisted-pair wire media. Options: DS Fiber modules. DVC-KD: Keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons. DVC-AO: Optional DVC Analog Output board provides four analog output circuits for use with AA or XPIQ Series amplifi- ers. Four-channel operation supported. CA-1: Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC and a DVC-KD (optional); and the right side houses a CMIC-1 microphone and its well (optional). CMlC-1: Optional microphone and microphone well assembly used with the CA-1 chassis. El Page 2 of 4— DN-7045:G • 01/16/2012 CFFT-1: The CFFT-i Chassis for Firefighters' Telephone mounts in the row directly under a DVC that is mounted in a CA-1 single row chassis. The CFFT-1 includes one FFT hand- set. The DP-CFFT Dress Plate (separately ordered, required) has one open position for mounting an ACS annunciator or a BMP-1 Blank Module Plate. CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC mounted on a half-chassis and one NFS2-3030 or NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes a microphone. DPA-2B dress plate is required (below); the VP-213 Vent Plate is also required for top row configurations. ADDR Series doors with two-tier visibility are available for use with the CA-2 configura- tion: ADDR-134, ADDR-C4, ADDR-D4 (below). DPA-213: Dress plate required for CA-2 chassis assembly. VP-2113: Vent plate required for cabinet configurations where the DPA-2B is used for the top two row position. TELH-1: Firefighters' Telephone Handset for use with the DVC when mounted in the CA-2 chassis. Order separately. ADDR-1134: Two-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-134. See DN-6857. ADDR-C4: Three-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-6857. ADDR-D4: Four-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-6857. DPA-1: Dress panel, can be used with the CA-1 chassis when configured with a DVC, DVC-KD, and CMIC-1. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-1 is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. ACT-4: Audio-coupling transformer. Used to electronically iso- late DVC-AO analog risers. ACT-25, ACT-70: Audio-coupling transformers for 25V and 70V high-level audio. Used to isolate and convert high-level audio to low-level, supporting applications with large numbers of analog amplifiers. DAX-3525(E)/DAX-3570(E): 35W, 25 or 70.7VRMS. Digital audio amplifiers with charging power supply and 2 Class B or 1 Class A output, shipped mounted on chassis. Options: BDA- 25/70 backup amplifier, DS Fiber modules. DAX-5025(E)/DAX-5070(E): 50W, 25 or 70.7VRMS. Digital audio amplifiers with power supply and 2 Class B or 1 Class A output, shipped mounted on chassis. Options: BDA-25/70 backup amplifier, DS Fiber modules. DAA2-5025(E)/DAA2-5070(E): 50W, 25 or 70.7VRMS. Digital audio amplifiers with charging power supply and 4 Class B or 2 Class A outputs, shipped mounted on chassis. RM-i port, FFT port, Aux audio port. Supports optional BDA for backup ampli- fier or 2-channel operation, and DS Fiber modules. DAA2-7525(E): 75W, 25VRMS. Digital audio amplifiers with power supply and 4 Class B or 2 Class A outputs, shipped mounted on chassis. AM-i port, FFT port, Aux audio port. Supports optional BDA for backup amplifier or 2-channel oper- ation, and DS Fiber modules. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC while retaining digital audio dis- tribuition capabilities. Can be configured with up to four DS- AMPs, supplying high-level risers spread throughout an instal- lation. See DN-60565. DS-AMP/E: 125W, 25 yAMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-BDA: Digital Series Backup Digital Amplifier, 25 or 70VRMS, can be configured to act as a one-to-one backup for DS-AMP/E amplifiers. Can also be programmed to provide a second audio channel for a DS-AMP. See DN-60663. 13DA-25, BDA-70: Backup Digital Amplifier, 25 or 70.7VRMS, can be configured to act as a one-to-one backup for DAX and DAA2 series amplifiers. For DAA2 Series only, supports alter- native second channel operation. DS-RFM, OS-FM, DS-SFM: Fiber conversion modules for DVC, DS-DB distribution board, and DAX and DAA2 Series amplifiers. See DN-60633. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running SR4.0. For DAA-50 series amplifiers, see DN-7046. For DAA-7525 Series, see DN-60257. - DAA-5025: SOW, 25Vrms Digital Audio Amplifier assem- bly with DAA-PS power supply board, shipped mounted to its chassis. Supports twisted-pair wire media. (For multi- mode fiber-optic media order DAA-5025F For single- mode fiber-optic media order DAA -5025SF) - DAA-5070: 50W, 70.7Vrms Digital Audio Amplifier assembly with DAA-PS power supply board, shipped mounted to its chassis. Supports twisted-pair wire media. (For multi-mode fiber-optic media order DAA-5070E For single-mode fiber-optic media order DAA-5070SF) - DAA-7525: 75W, 25Vrms Digital Audio Amplifier assem- bly with DAA-PS power supply board. Shipped mounted to its chassis (no battery charger on DAA-7525 power supply board). Supports twisted-pair wire media. (For multi-mode fiber-optic media order DAA-7525F For sin- gle-mode fiber-optic media order DAA-75255F) SEISKIT-CAB: Seismic kit for CAB-4 series cabinets. Includes battery bracket for two 26AH Power Sonic batteries and TELH- 1 telephone handset strap. See document 53829. SEISKIT-DAA: Seismic kit for DAA, DAA2 and DAX series amplifiers, required when using CHS-BHi chassis. Includes battery bracket for two 12AH Power Sonic batteries. See docu- ment 53851. DN-7045:G • 01/16/2012 - Page 3 of 4 DN-60565:A 0 NOTIFIER® by Honeywell General DS-DB Digital Series Distribution Board The DS-DB Digital Series Distribution Board and its associ- ated amplifiers provide bulk amplification capability to the Digi- tal Voice Command (DVC) system while retaining digital audio distribution capabilities. Up to four DS-AMP/E amplifiers can supply high-level risers spread throughout an installation. The DS-DB converts digital audio to analog and routes it to audio amplifiers and optional backups. The amplifiers send back high-level audio, which the DS-DB routes to its risers. Control and status information passes between the DS-DB and its components via EIA-485 bus. The DS-DB communi- cates with the rest of the digital audio system through the DAL (digital audio loop), and takes up two of the 32 DAL addresses. It may be mixed with other devices on the same DAL, such as the DAA2 and DAX series amplifiers. An optional Firefighters' telephone riser on the DS-DB sup- ports local and network FFT communications. Features Input capacity of four digital audio channels. Four DVC-AO-IeveI audio outputs for connection to amplifi- ers in the same cabinet. Eight high-level audio inputs (four primary, four backup), each input capable of handling 125W of audio at 25VRMS or 100W at 70.7VRMS. Four Class Neight Class B high-level 125W audio outputs, each of which can output all 125 watts from any one of the four high level primary inputs or four high-level backup inputs. Two digital audio loop wire ports, which may be modified to single- or multi-mode fiber ports with fiber option modules. USB port for VeriFire Tools® communication. Local FFT riser, capable of acting as a connection on the digital FFT riser. DS BUS interface to communicate with local bulk amplifiers and power supplies. Up to 106 seconds of standard quality backup digital mes- sage storage (from VeriFire Tools® message library, or cre- ated by the installer) for use in the event of communication loss with the DVC. Isolated alarm bus input, to be used for backup activation of alarm messages when normal communication with the DVC is lost. Audio output activation via network control-by-event equa- tions resident within the DVC. Uploads and downloads via the DVC. 24 VDC input for local power. Works with AMPS-24 power supply and battery charger. Installation The DS-DB arrives from the factory already installed on its chassis. The DS-DB mounts in a CAB-4 Series cabinet, as well as in an EQCAB Series backbox. One or two fiber option modules will plug directly onto a DS- DB for simple installation. A DS-BDA backup amplifier mounts directly onto a DS-DB. Specifications 24 VDC Input (TB24): 0.6A alarm or standby, non-resettable. Power-limited by source, supervised. Any device connected to 1B24 must be installed in the same enclosure, or within the same room in conduit. Digital Audio Ports, wire media, A and B: EIA-485 protocol, power-limited. Maximum distance per segment is 1900 feet (579.12m) on Belden 5320UJ (18AWG, TP) FPL cable: 18AWG (0.821 mm2) twisted-pair, unshielded, power-limited. For approved cable types, see wiring documentation, PN 529 16ADD, Approved Wire Cables for Digital Audio Loops. Digital Audio Ports, fiber media, fiber option modules: Dig- ital audio loop connectors support single- and multi-mode fiber with the use of fiber option modules. Refer to the fiber option datasheet for fiber specifications. Alarm Bus: Power-limited, supervised by source. Recom- mended wiring: 14-18 AWG twisted-pair. Requires 16VDC minimum @ 20mA across the terminals to activate. Nominal 24VDC. FFT Riser: Power-limited output, supervised. Class A or Class B operation. Class B 2-wire connections require a 3/9k ohm 1/ 2 watt resistor (PN R-3.9K). Max. wiring resistance (including individual telephone zone to last handset) permitted is 50 ohms, 10,000 ft (3048 m) max. wiring distance at 14 AWG to last handset. DS-BUS: EIA-485 protocol, power-limited. DS-BUS points must be installed in the same enclosure or within the same room in conduit. End points require end-of-line resistors. DS-DB endpoint: set termination switch (SW8)to ON. DS-AMP endpoint: add 120 ohm resistor on empty TB1 ter- minals. AMPS-24 endpoint: resistor is present, and power supply must be an endpoint. Use 14-18 AWG, twisted unshielded wire. Audio Out: Power-limited outputs (exception: an output pro- grammed for "Riser Mode to Control Modules", "Riser Mode to RSM-AIM Series Modules", or "Riser Mode to CIM/CSM Series Modules" is non-power-Iimited.)Up to 125 Watts output. DN-60565:A.O1/16/2012—Page 1 of 2 Supervision determined by programming. 25VRMS or 70VRMS, DS-FM: Fiber option module for multi-mode fiber. Converts a depending on amplifier setting. Class A or Class B operation, wire DAP (digital audio port) to a multi-mode fiber port. See Class B requires 20k end-of-line resistors (included, PN ELR- DN-60633. 20K). Class A required 10k end-of-line resistors (included, PN DS-SFM: Fiber option module for single-mode fiber. Converts . A-10K) on the return. 12-18 AWG twisted-pair (shielded rec- a wire DAP (digital audio port) to a single-mode fiber port. See ommended). DN-60633. Primary and Backup 1 thru 4: Four DVC-AO-level audio out- DS-RFM: Fiber option module for multi-mode fiber. Used puts for connection to amplifiers. Non-power-limited inputs, exclusively for compatibility with multi-mode fiber DVC or DAA. Supervision programmable. Amplifiers must be installed in the See DN-60633. same enclousre or within the same room in conduit. Recom- mended wiring: 14-18 AWG, twisted-pair, unshielded. OUT: Four DVC-AO-level audio outputs for connection to amplifiers. Power-limited. Supervision programmable. Amplifi- ers must be installed in the same enclosure or within the same room in conduit. 14-18 AWG, twisted-pair, unshielded. Standards and Codes The DS-DB Digital Series Distribution Board complies with the following standards: NFPA 72 2007 National Fire Alarm Code Underwriter Laboratories Standard UL 864 Underwriter Laboratories of Canada (ULC) ULC-S527-99 Standard of Control Units for Fire Alarm Systems Part 15 Class A conducted and radiated emissions as required by the FCC. Listings and Approvals These listings and approvals apply to the DS-DB Digital Distri- bution Board. In some cases, certain modules may not be listed by certain agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 ULC Listed: S635 CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). FDNY: COA#6065 (NFS2-3030): COA#6085 (NFS2-640). Product Line Information DS-DB: Digital Series Distribution Board. OS-AMP: 120 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMS), 100W (70VRMs). Ships with chassis. See DN- 60663. DS-AMPE: 220-240 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMS), 100W (70VRMs). 70VRMS configuration requires step-up transformer. Ships with chassis. See DN- 60663. DS-BOA: Backup amplifier, provides an economical means of backup for DS-AMP amplifiers in a one-to-one primary/backup configuration. Can also provide a second audio channel for a DS-AMP when programmed as a primary ampifier. 25VRMS or 70VRMS . 70VRMS configuration requires step-up transformer. See DN-60663. DS-XF70V: Step-up transformer, required for 70VRMS config- NOTIFIER® and yen-F.ire® are registered trademarks of Honeywell uration of DS-AMP/E and DS-BDA. Ordered separately. See International Inc DN-60663. 02012 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SII 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. W IGiNEiNG & MMUFACTUMNI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60565:A • 01 /16/2012 DN-60663:A NOTIFIER® by Honeywell General DS-AMP Digital Series Amplifier for use with the DS-DB Distribution Board As part of a DS-DB Digital Series system, the DS-AMP Digital Series amplifier provides bulk amplification to a Digital Voice Command (DVC) system. Up to four DS-AMP amplifiers can be connected to one DS-DB to supply high-level audio. Backup audio circuits are available by adding DS-BDA or dedi- cated DS-AMPs. Features 125 watts of audio power at 25VRMS. 100 watts of audio power at 70VRMS. This option requires step-up transformer DS-XF70V, ordered separately. Compatible with a DS-BDA that is being used as a backup or second audio channel. (A DS-BDA used as a backup or second channel for a DS-AMP configured for 70VRMS requires step-up transformer DS-XF70V, ordered sepa- rately.) EIA-485 communication with DS-DB. Installation The DS-AMP arrives from the factory already installed on its chassis. It mounts in one row of any EQ or CAB-4 Series cabi- net. The CAB-4 row can be covered using a DP-1B dress panel, ordered separately. A step-up transformer (ordered sep- arately) easily mounts on the front of the DS-AMP for 70VRMS configurations. Specifications AC Power, TB4: 120 VAC 50/60Hz input; 4.1 A maximum when used for 25V (125W). 3.55 A maximum when used for 70V (100W). Eversion: 220-240 VAC 50/60 Hz input; 2.4 A maximum when used for 25V (125W). 2.1 A maximum when used for 70V (100W). Recommended wiring: 12-14 AWG (1.6 mm O.D.) with 600 VAC insulation. Battery Connections: Supplied cable connections to batter- ies. For battery sharing, use 12 AWG either in the same cabinet or in conduit for no more than 20 feet (6.09 meters). High Level output (TB3): Non-power-limited, supervision pro- vided by DS-DB. Recommended wiring: 14-18 AWG, twisted- pair, unshielded. Audio In (TB2): Power-limited, supervision provided by DS- DB. Recommended wiring: 14-18 AWG, twisted-pair, unshielded. Standards and Codes The DS-AMP amplifiers comply with the following standards: NFPA 72 2007 National Fire Alarm Code. Underwriter Laboratories Standard UL 864. Underwriter Laboratories of Canada (ULC) ULC-S527-99 Standard of Control Units for Fire Alarm Systems. Part 15 Class A conducted and radiated emissions as required by the FCC. Listings and Approvals These listings and approvals apply to the DS-AMP amplfiers. In some cases, certain modules may not be listed by certain agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: S635. ULC Listed: S635. CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). FDNY: COA#6065 (NFS2-3030): COA#6085 (NFS2-640). Product Line Information DS-AMP AMPLIFIERS Shipped mounted to the chassis. DS-AMP: 120 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMS), 100W (70VRMS). DS-AMPE: 220-240 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMS), 100W (70VRMS). 70VRMS configuration requires step-up transformer. DS-BDA AMPLIFIER Backup amplifier, provides an economical means of backup up DS-AMP amplifiers in a one-to-one primary/backup configura- tion. Can also provide a second audio channel for a DS-AMP when programmed as a primary amplfier. DS-BDA: 25VRMS or 70VRMS. 70VRMS configuration requires step-up transformer. STEP-UP TRANSFORMER DS-XF70V: Transformer required for 70VRMS configuration of DS-AMP/E and DS-BDA. Ordered separately. C DN-60663:A.O1/16/2012—Pagel of 2 S Appendix A: DS-DB and DS-AMP Battery Calculations Description Column A Amps in Standby Column B Amps in Alarm QTY X current draw = Total QTY X current draw = Total DSDB* I X ( 0.355A ] = 0.355A 1 X [ 0.550A ] = 0.550A DS-FM (all models) [ ] X [ 0.060A ] = [ ] X [ 0.060A ] = 24V Auxiliary Power (TB24 on DSDB)** I ] X[ ] = [ ] X ( ] = DS-AMP (25V) [ ] X [ 0.125A ] = [ ] X [ 0.280A ] = DS-BDA (25V) [ ] X [ 0.100A ] = [] X [ 0.300A ] = DS-AMP (70V) [ ] X[ 0.130A ] = [ ] X[ 0.300A ] = DS-BDA (70V) [ ] X [ 0.105A ] = [ ] X [ 0.330A ] = AMPS24*** [ ] X[ 0.130A ] = [1 X[ 0.130A ] = Speakers: 1/4 waft 1/2 waft 3/4 watt 1 watt 2watt Other [ ] X[ 0.016A ] [] X[ 0.031A ] [1 X [ 0.047A ] = : [ ] X [ 0.062A j = [ ] X[ 0.124A ] [ ] X[ [ ] X[ 1= Total Column A Total Column B * Includes FFT Riser Draw Refer to the documentation that comes with the device(s) being powered through the DS-DB's TB24 for standby and alarm figures. ***If the AMPS-24 is powering additional components, refer to the AMPS-24 manual for standby and alarm figures. Table A.1 Current Draw Calculations for DS-DB and DS-AMP DS-DB—P/N 53622:B2 9/11/2014 53 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7165-0028:0243 Page 1 of 4 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models NFS2-640, NFS-320/C (R), and NFS-320SYS fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), manual, automatic, waterfowl and sprinkler supervisory services. Also suitable for releasing service, Process Management and Emergency Voice/Alarm communication System * Model numbers may be followed by an "R" suffix representing the enclosure color being red. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ACM-8R, -16AT, -32A, -24AT, -48A; Annunciator Control Modules ACPS-610, AMPS-24; Addressable power supply/charger ADP-413, -A4, -1, -2, DP-D1SP2; Dress Panel AEM-16AT, -32A, -24AT, -48A; Annunciator Expander Modules AFM-16A, -16AT, -32A; Annunciator Fixed Modules AKS-113; Annunciator Key Switch APS2-6R; Power supply BB-100, -200, NFS-LBB/-LBBR; Battery Boxes BGRA-SCS, BGRB-SCS; Smoke Control Station BMP-1; Blank Module BP-4, BP24; Battery Dress Plates CAB-3/4 Series; Enclosure CAB-RP, CAB-RPR; Cabinets CEF-SCS; Smoke Control Station CHS-4, CHS-4N, CHS-4L; Chassis CPU2-640, CPU-320SYS; CPU Board CRT-2; Display Terminal DP-1B; Blank Panel DPA-1A4/1/2, DP-DlSP2; Dress Panel DPI-232; Panel Interface DR-A4, DR-A413, DR-A4BR, DR-A4R; Door Assembly DR-AA4, DR-AA4B, DR-AA4BR, DR-AA4R; Door Assembly DR-133F; Door Assembly DR-134, DR-13413, DR-B4BR, DR-134R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly *Rev. 10-29-13 gt 1I4, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 01 Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 2 of 4 EQ Series; Cabinets EQBB-84, EQBB-C4, EQBB-D4; Backbox Assembly . EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1, FCM-1-REL; Releasing Control Module FCPS-2456, -24S8; Field Charger/Power Supply FDM-1; Dual Monitor Module FDRM-1 Multiple Module with two Relay Outputs FDU-80/-80G; Remote Annunciator Fl RSTVISION-LCD/ENC; Interactive Firefighters' display/enclosure FRM-1; Relay Module FTM-1; Control Module FZM-1, FMM-1, FMM-101; Monitor Modules HS-NCM-W/-M F/-SF/-WM F/-WSF/-MSSF; High Speed Network Control Modules IPDACT-2/-2UD; IP Fire Alarm Communicator ISO-X; Isolator Module KAPS-24, CPS-24; Power Supply KDM-R2; Keyboard Display Module LCD-80, -160; Annunciators LCD-80TM; Annunciator Terminal Module LCD LCD2-80; Remote Annunciator LDM-32/-E32/-R32; Lamp Driver Module LEM-320/ELEM-320; Loop Expander Module NBG-12LRA; Agent Releasing Abort Station NBG-12LX; Addressable Manual Pull Station NCA, NCA-2; Network Communication Annunciator NCM-W, -F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station NFS-LBB/NFS-LBBR; Battery Box/Red NFS-320SYS; Chassis NFV-25/50, NFV-25/50ZS/ZST; Voice Evacuation Control Panels NFV-25/50DA, NFV-25/50DAZS; Distributed Audio Panels ONYXWorks-EW/-NW-/NF/-HNW/-H NMF/-HNSF/-TS/-EW-TS/-NF-TS/-HW-TS/ -HNMFT/-HNSFT/-HNwr; PC workstation for NOTI.FIRE.NET, Wire/Fiber/ with Touch screen monitors PRN-6; Printer RKS-S; Remote Security Key Switch RPT-W, -485W; Repeater Wire RPT-F; Repeater Fiber RPT -485FW; Repeater Fiber/Wire RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-M4R; Backbox Assembly SBB-B4, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 3 of 4 SCE-8; Smoke Control Expander SCS-8L; Smoke Control Lamp Driver Station SCE-8L; Smoke Control Expander Lamp SCS-8; Smoke Control Station STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A41-B3NI-B4/-C4/-D3NI-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-256; Universal Zone Coder VP-213; Dress Panel XPS-C/-M; Transponder Modules XP6-C; Supervised Control Modules XP6-MA; Six Zone Interface Modules XP6-R; Six Relay Control Modules XP1O-M(A); Ten Input Monitor Modules XPM-8L; Transponder Monitor Modules The following models are intended for use on NFS2-640 only: AA-30, -100, -120; Amplifiers ACT-1, -2, -4, -25, -70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4R/-D4/-D4R; Door Assemblies AMG-E; Audio Message Generator AVL-1; Audio Voice Link BDA-25V/-70V; Backup Digital Audio Amplifiers CHS2-M2, CA-11, CA-2; Chassis CMlC-1, CMlC-RP; Microphone Assembly DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-5025SF; Digital Audio Amplifiers DAA-5070F/DAA-50705F; Digital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-7525SF; Digital Audio Amplifiers DAA2-5025/-5070/-7525; DigitalAudio Amplifiers DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DVC; Digital Voice Command DVC-EM/-EMF/-EMSF; Digital Voice Command Extended Memory Module DVC-RPU; Remote Paging Unit FFT-7, -7S; Fire Fighter's Telephone FHS; Fireman's Handset FPJ; Fireman's Phone Jack RM-1, RM-i SA; Remote Microphone Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator . Fire Engineering Division Listing No. 7165-0028:0243 Page 4 of 4 TELH-1; Telephone Assembly XPIQ; Transponder Quad Intelligent Audio INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label APPROVAL: Listed as fire alarm control units suitable for use in high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. *Control units may be used with Notifier's First Command NFC-501100 emergency voice evacuation panals (CSFM # 6911-0028:0265). This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 Seconds. 2. Combined with 7170-028:244 *Rev. 10-29-13 gt søTI4c,• This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 000 Search dmpatarms Add cellular communications to any fire panel Extend the life and expand the capabilities of older panels by adding the power of advanced, digital cellular communication. With this simple communications add-on, almost every panel can take advantage of revenue-building remote system management and control features. Provide central station communication over cell for any burglary, commercial fire or residential fire panel Use Contact ID capture. 4 zones, or Bell Monitoring 0 CellComSLCTM and CellComSLCF enables basic remote panel control via Virtual Keypad AppTM Provides end user alerts of arming/ disarming, alarm, and other events Add Z-Wave control of lights, locks, and thermostats with CellComSLCZTM CELLCOMSL SERIES UNIVERSAL ALARM COMMUNICATOR SYSTEM FEATURES Fully supervised universal alarm communication over CDMA Fully supervised universal fire alarm communication over CDMA Program your own account number to easily workaround locked panels Contact ID dialer capture Four zones or Bell Monitoring Wiring for Ademco ECP Bus Communicates with DMP SCS-1 R and SCS-VR Receivers Builds customer loyalty; creates new RMR Armed/disarmed status LED Private labeling available on the rubber logo insert WKSW1ThMOST PANELS If the existing panel supports Contact ID. then it's a candidate for upgrading with the CellComSLC. CeLlComSLCZ. or CellComSLCE There are no issues with lockout codes. Simply add the CeLlComSL unit to the existing installation and program in your own account number. AVAILABLE BURGLARY COMMUNICATION The CelLComSLC provides control of basic panel security functions and video. The CellComSLCZ adds the ability to remotely interact with Z-Wave devices, enabling a variety of home automation features including control of lights, door locks, thermostats and more. FIRE COMMUNICATION The CeltComSLCF offers cellular fire communication on any fire control panel via Contact ID Captures or Zone Inputs. Meets NFPA 72 Standard for Single Communication Technology. S MOBILE SYSTEM CONTROL With CellComSL communicators you can easily update your older residential and commercial customers to the latest cellular communication Links. With cellular in place, end users can remotely access their panels via the Virtual Keypad AppTM. This makes it possible to use their mobile device not only to control basic arm/disarm functions and receive alerts, but also to control Z-Wave home automation devices for tights, door locks, thermostats, and more with CellComSLCZ. ENABLE VIDEO ON THE APP Video is no Longer an expensive option. With the CellComSLC communicators, you can easily add up to six wireless cameras. Via the Virtual Keypad App, end users can do a remote visual survey of their premises to confirm an alarm or simply check in on children or senior adults. Users can also capture still or video images. FULLY SUPERVISED COMMUNICATION Provides a fully supervised alarm communication path for burglary control panels over the COMA network providing higher speeds. CellComSL allows alarm messages to be communicated to an SCS-1 R orSCS-VR Receiver overthe COMA network. COMA operates on the Verizon network. FIELD PANEL UPDATES The Model 400 USB Flash Module allows you to easily field update firmware for panels that would otherwise require the use of a computer and a Model 399 Programming Harness. SYSTEM PROGRAMMING System programming over cell via VirtualLinkTM includes zone information and Central Station communications. MULTIPLE CONNECTION OPTIONS CelLComSL communicators can be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer, or connect the four input zones from outputs on the panel; or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the Central Station. FOUR ZONES Each of the CellComSL models provide four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. EASY UPGRADE FOR DIALER- ONLY PANELS Older, dial-up panels have new Life with the addition of cellular communication. Earn customer loyalty by extending the life of their existing panels, enabling them to increase the ROI on their system investment and build satisfaction with the purchase decision. BUILD CUSTOMER LOYALTY Avoid the possibility of customers seeking mobile intrusion alarm features from a competitor by enabling those features on their existing panel with a minimal additional cost. They are Less likely to switch systems and cancel their contract. When the time does come to replace the panel, they are more likely to rely on you. The app can be branded with your organization's logo and contact information to provide a daily reminder of your services. OUTPUTS Use outputs to connect to an arming zone of an existing panel for control of that panel via the App. SPECIFICATIONS Dimensions: 5.5" W X 3.75" H x 1 0 Color: White Open-Collector Outputs: 2 Zones: 4 Primary Power (CellComSLC/SLCZ): 12VDC Primary Power (CellComSLCF): 24VDC Current Draw: Alarm .181 mA Standby .061 mA ORDERING INFORMATION CellComSLC Universal Alarm Communicator CellComSLCF Universal Fire Alarm Communicator ëfiãThSL-&Z-----_iJjiiversal Alarm Communicator, Z-Wave In, 471 s . ~-n CERTIFICATIONS California State Fire Marshal (CSFM) ANSI/UL 1610 Central Station Burglar (Cellular) ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning (CID Capture) ANSI/UL 864 Fire Protective Signaling Systems Cellular FCC Part 15: MIVCNNO301 CellComSL FCC Part 1510: CCKPC0159 IC: 5251APC0159 2500 North Partnership Boulevard 800.641.4282 I dmp.com Springfield. Missouri 65803-8877 Designed. Engineered & Manufactured in Springfield. Missouri CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1157:0136 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton©dmp.com DESIGN: Models CelICom5LCF, CelIComSLCZ, *CellComSLCF* iComSLF, iCOMSL and iComSLZ Communicators. Refer to listees data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. RATING: 12 VDC or 24 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and ETL label. APPROVAL: Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to Iistee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *Rev. 07-14-15 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division iI1L-1 S y The SpectrAlert Advance Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pie-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 11 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while the SPV speaker offers high volume sound output for use in high ambient noise applications. SpectrAlert Advance makes installation easy Attach a universal mounting plate to a 4 x 4 x 21/8 inch back box. Flush-mount applications do not require an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Rotate the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SYSTEM SENSOR® Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications SpectrAlertO Advance selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation. Features Plug-in design and protective cover reduce ground faults Universal mounting plate with an onboard shorting spring tests wiring continuity before installation No extension ring required Field selectable candela settings: Standard: 15, 15/75, 30, 75, 95, 110, 115 High: 135, 150, 177, 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4,1/2, 1 and 2 watts) SP speakers offer high fidelity sound output SPV speakers offer high volume sound output Compatible with System Sensor synchronization protocol Electrical compatibility with existing SpectrAlert products Optional tamper resistant Torx head screw included Listed for ceiling or wall mounting Agency Listings SIGNAliNG ®j MEA LISTED approved S4048 7320-1653:201 10-06-E SpectrAlert Advance Speaker and Speaker Strobe Specifications General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 21,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync.CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411/16 x 411/16 x 21j8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Ceiling-Mount SPS Speaker Strobe 6.8 in Dia. x 4.7 in D (including lens and speaker) SPSV Speaker Strobe 6.8 in Dia. x 4.8 in 0 (including lens and speaker) SP Speaker 6.8 in Dia. x 2.8 in D SPV Speaker 6.8 in Dia. x 2.9 in D _____________ ., ........ ,. . ,..• ,. .., . . .. . Nominal Voltage (speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 V DC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) alarm panels with built in sync) Operating Voltage with MDL Sync Module 9 to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz Power 1/4,1/2, 1, 2 watts AVDSOO7O1 [I 6.81 UL Current Draw Data .IJu.11TrJ?1iiu.1Iaij . 8to17.5Volts l6to33Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 !TTTI.1TIr1T UL Reverberant (dBA @ loft.) 2W 1W ½W Ceiling-Mount SPC Series 86 83 80 77 Ceiling-Mount SPCV Series 90 87 84 81 Ceiling-Mount SPSC Series 85 82 79 76 Ceiling-Mount SPSCV Series 89 86 83 80 Dimensions Ceiling-Mount SPV Speaker I 6.81 Ceiling-Mount SP Speaker [IJ Ceiling-Mount SPS Speaker Strobe AVDSOO7O1 Surface Mountinci Ce Ceiling-Mount Speaker with SPBBSCW Back Box Ordering Information for SpectrAlertO Advance Speakers and Speaker Strobes ________4,00 OPM White Red Description SPCW SPCR Speaker only SPC\NV SPCRV Speaker only, High dB SPSCW SPSCR Speaker Strobe, Standard cd SPSCWH* SPSCRH Speaker Strobe, High cd SPSC\AN* SPSCRV Speaker Strobe, Standard cd, High dB SPSCNH SPSCRVH Speaker Strobe, High cd, High dB SPSCW-CLR-ALERT - Speaker Strobe, Standard cd, Clear Lens White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SPBBSCW SPBBSC Ceiling Mount Back Box Skirt TRCW TRC Ceiling Mount Trim Ring Notes: * Add -P to model number for plain housing (no "FIRE" marking on the cover) e.g. SPSCW-P t "Standard cd' refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. sywaff 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject ro1change without nosce.vidtsystemsensor.cmo ©202 System Sensor. SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information, inctudiog the latest version of this data Sheet. AVDS0 0 701 • 3/12 I pli;r~;161. Z-e S "~"" 'P~t S I The SpectrAlert Advance Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 11 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while the SPV speaker offers high volume sound output for use in high ambient noise applications. SpectrAlert Advance makes installation easy Attach a universal mounting plate to a 4 x 4 x 21i8 inch back box. Flush-mount applications do not require an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications The SpectrAlen`0 Advance selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation. Features Plug-in design and protective cover reduce ground faults Universal mounting plate with an onboard shorting spring tests wiring continuity before installation No extension ring required Field selectable candela settings: Standard: 15, 15/75, 30, 75, 95, 110, 115 High: 135, 150, 177, 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4,1/2, 1 and 2 watts) SF speakers offer high fidelity sound output SPV speakers offer high volume sound output Compatible with System Sensor synchronization protocol Electrical compatibility with existing SpectrAlert products Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGIWJUG S® MEA LISTED approved S4048 7320-1653:201 10-08 SpectrAlert Advance Speaker and Speaker Strobe Specifications JIM General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 21,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync'CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411116 x 411/16 x 21,8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non- Dimensions, Wall-Mount Length Width Depth SP Speaker 6 in, 152 mm 5 in, 127 mm 2.8 in, 71 mm SPV Speaker 6 in, 152 mm Sin, 127 mm 2.9 in, 74 mm With Surface Mount Back Box 6 in, 152 mm 5.1 in, 130 mm 3.4 in, 86 mm SPS Speaker/Strobe (including lens and speaker) 6in, 152 mm 5.1 in, 127 mm 4.7 in, 119 mm With Surface Mount Back Box 6 in, 152 mm 5.1 in, 130 mm 5.325 in, 135 mm Nominal Voltage (speakers) 25 Volts or 70.7 Volts - Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC/ FWIR or regulated 24 DC/FWlR Operating Voltage Range (includes fire 8 to 17.5 V (12 V alarm panels with built in sync) nominal) or 1610 33V Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33V (24 V nominal) Frequency Range 400 to 4000 Hz Power ¼,½,1,2watts Dimensions . I- 5.00: 5 Wall-Mount SP Speaker Wall-Mount SPS Speaker Strobe UL Current Draw Data LuJ.1.iIP1Zmfi:lF . Candela 8to17.5Volts l6to33Volts DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 TlT(s11UT1 UL Reverberant (dBA @ loft.) 2W 1W ½W ¼W Wall-Mount SP Series 86 83 80 77 Wall-Mount SPV Series 90 87 84 81 Wall-Mount SPS Series 85 82 79 76 Wall-Mount SPSV Series 89 86 83 80 0 Surface Mounting Wall-Mount Speaker Strobe with SBBSPR Surface Mount Back Ordering Information for SpectrAlert® Advance Speakers and Speaker Strobes White Red Description SPW SPA Speaker only SPWV SPAV Speaker only, High dB SPSW SPSR Speaker Strobe, Standard cd SPSW-P SPSR-P Plain Speaker Strobe, Standard cd SPSW-ALERT - Speaker Strobe, Standard cd, Amber Lens SPSW-CLR-ALERT - Speaker Strobe, Standard cd, Clear Lens SPSWH SPSRH Speaker Strobe, High cd SPSWH-P - Plain Speaker Strobe, High cd SPSWV SPSRV Speaker Strobe, Standard cd, High dB SPSWV-P SPSRV-P Plain Speaker Strobe, Standard cd, High dB I!1ft*i White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBSPW SBBSPR Surface Mount Back Box for Speakers and Speaker Strobes TRW TA Wall Mount Trim Rina Notes: All -P models have a plain housing (no "FIRE" marking on the cover) "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. 3825 Ohio Avenue • St. Charles, IL 60174 02015 System Sensor, 0 Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change Without notice. Visit systenisensorcorn for current product information, including the latest version of this data sheet www.systemsensor.com AVDS11602. 2/15 Outdoor, Selectable- Output Speaker Strobes and Dual- Voltage Evacuation Speakers for Wall Applications SpectrAlertO Advance outdoor, selectable-output speaker strobes and dual-voltage evacuation speakers meet virtually any outdoor application requirement. Features SpectrAlert Advance offers the broadest line of outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic housings, to wall and ceiling mounting options, SpectrAlert Advance can meet virtually any application requirement. Weatherproof per NEMA 4X, 1P56 Rated from -40°F to 151°F Plug-in design reduces ground faults Universal mounting plate with onboard shorting spring that tests wiring continuity before devices are installed Field-selectable candela settings: 15,15/75,30,75,95,110,115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for speaker voltage (25 and 70.7 Vrms) and power settings (1/4, 1/2, 1 and 2 watts) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings ® SIGNAUNG MEA LISTED approved 75S0 7320-1653:201 10-06-6 Wall-mount outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from -40°F to 151°F. These speakers provide a broad frequency response range, low harmonic distortion and maintain a high sound pressure level at all tap settings to provide accurate and intelligible broadcast of evacuation messages. Like the entire SpectrAlert Advance line, wall-mount outdoor speakers and speaker strobes include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, speaker voltage and power settings, and automatic selection of 12- or 24-volt operation enable installers to easily adapt devices to meet requirements. Next, these devices use a universal mounting plate with an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 34-inch top and bottom conduit entries and 3,4-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Speaker and Speaker Strobe Specifications * General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync'Circuit°° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40°F and 151°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems. Speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature from -40°F to 150.8°F. Speaker shall have power taps and wattage settings that are selected by rotary switches. The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048. The speaker shall be suitable for use in air handling spaces and wet environments. Speaker Strobe Combination The speaker strobe shall be a System Sensor Model listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4,000 Hz. Speaker shall have power taps that are selected by rotary switch. The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts. The strobe shall also feature selectable candela output, providing options for 15 or 15/75 candela when operating on 12 volts and 15, 15/75, 30, 75, 110, 115, 135, 150, 177 or 185 candela when operating on 24 volts. The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The speaker strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151°F (-40°C to 66°C) Dimensions, Wall-Mount SPS Speaker Strobe 60" L x 5.0"W x 47" D (including lens and speaker) SP Speaker 6.0-L x 5.0"W x 2.9-D Dimensions, Wall-Mount Weatherproof Back Box 6.5L x 5.5"H x 2.9"D Nominal Voltage (speakers) 25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) panels with built in sync) Operating Voltage with MDL Sync Module 9 to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz Power 1/4,1/2, 1, 2 watts AVDSO1001 [] a, Dimensions 5.48' 6.45- UL Current Draw Data Candela Derating U L Max, Strobe For K series products used at low S 8 to 17.5 Volts 16 to 33 Volts temperatures, listed candela ratings must be Candela DC FWR DC FWR reduced in accordance with this table. lTltputI) Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 Candela Range 150 177 185 $666d Output NA NA NA NA NA NA NA NA 228 246 281 286 207 220 251 258 UL Reverberant (dBA @ loft.) 2W 1W 1/2W ¼W Outdoor Speaker 90 87 84 81 Outdoor Speaker/Strobe 89 86 83 80 Wall-Mount Outdoor Speaker Wall-Mount Outdoor Speaker Strobe AVDSO1001 Surface Mounti Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Ordering Information for SpectrAlert® Advance Outdoor Speakers and Speaker Strobes ISiE1ii1 I White Red Description SPWK* SPRK* Outdoor Speaker (includes plastic weatherproof back box) SPSWK*t SPSRK*t Outdoor Speaker Strobe, Standard cd (includes plastic weatherproof back box) SPSWK-CLR- - Outdoor Speaker Strobe, Standard cd, Clear Lens, ALERT Printed ALERT (includes plastic weatherproof back box) - SPSRHK Outdoor Speaker Strobe, High cd (135,150,177,185) (includes plastic weatherproof back box) WS 7 7 1A White Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box Notes: "Add "-R" to model number for weatherproof replacement device (no back box included), e.g., SPWK-R. tAdd "-P' to model number for plain housing (no "FIRE" marking on cover), e.g., SPSWK-P. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units, both the device and back box must be replaced. .,'TEtYA7 @2012 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensor.ccec ...' Phone: 800-SENSOR2 • Fax: 630-377-6495 AVOSOrOOt •03/12 for current product information, including the latest version of this data sheet. S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7320-1653:0201 Page 1 of 1 CATEGORY 7320 -- SPEAKERS LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models SPR,SPW,SPRV, and SPVVV SpectrAlert Speakers - Rectangular enclosure. Models SPCW, SPCR, SPCWV, and SPCRV SpectrAlert Speakers with round enclosure. Models SPSR, SPSRH, SPSW, SPSW-ALERT, SPSW-CLR-ALERT, *SPSWIKCLR..ALERT SPSWH, SPSRV, and SPSWV SpectrAlert Speaker/Strobe with rectangular enclosure. Models SPSCR, SPSCRH, SPSCW, *SPSCWKCLRALERT SPSCWH, SPSCRV, SPSCRVH, SPSCWV, and SPSC\IWH SpectrAlert Speaker/Strobe with round enclosure. Model SPSCW-CLR-ALERT Speaker/Strobe. Model SPSW-ALERT has amber lens and is intended for non-fire use. All models identified are intended for indoor use mounted on the wall or ceiling. Models with a "K" in the suffix are suitable for indoor or outdoor use with an operating temperature rating of -40°C to +66°C (-40°F to +151°F) and have a NEMA 4X enclosure rating when used with models PWBB, PWBBW (wall) or the model PWBBCW (ceiling) plastic weatherproof back boxes or with Model MWBBW (Wall), MWBB (Wall) or MWBBCW (Ceiling) metal weatherproof back boxes. Models with a '- P' in the suffix have plain housings with no lettering on the enclosure. Models not containing '- P", in the suffix have English lettering • reading "FIRE" on the housing. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Nominal Voltage: 25 Vrms or 70 Vrms Power Settings: 1/4,1/2, 1, 2 Watts Frequency Range: 400 - 4000 Hz INSTALLAT-ON: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL Listed as speaker/strobes when used with separately listed compatible fire alarm control units. Suitable for wall or ceiling mount. These speaker/strobes do not generate a distinctive three-pulse temporal code pattern (for total evacuation) as required per NFPA 72, 2010 edition. If required, the appliances must be used with a fire alarm control unit that can generate the temporal pattern signal. *Corrected 02-06-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. SPKTRMert SVS o Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL sync module Listed for ceiling or wall mounting Agency Listings SIGNAUNG MEA LISTED 54011 (Chimes, horn sloshes, 55512 (strobes( APPROVED horns( 3023572 approved MEA452-05-E 7125-1653186 (indoor strobes) 7125-1653:188 (horn strobes, chime strobes( 7135-1653:189 (horns, chimes) The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. S SpectrAlert Advance Specifications General - SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wa I products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit"° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SyncsCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21M-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. .Physicalffiiectrlcal Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2,5" high (173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1"diameter x 2.2" high (180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, 6.9" diameter x 0.35" high (175 mm diameter x 9 m high) TRCW-HS) Notes: Full Wave Rectified (F\NR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. F, 5, PC, and SC prod icts will operate at 12 V nominal only for 15 and 15/75 cd. AVDSOO5O1 UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temnoral Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR 24461t Nominal Reverberant DC FWR Anechoic DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes AVOSOO5O1 a. Ceiling-mount horn strobes SpectrAlert Advance Dimensions 22 7.1 101 0 Ceiling back box skirt SpectrAlert Advance Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2R* 2-Wire Horn Strobe, Standard cd, Red SCR Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red PC2W*t 2-Wire Horn Strobe, Standard cd, White SCW* Strobe, Standard cd, White PC2WH* 2-Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red Accessories PC4AH 4-Wire Horn Strobe, High cd, Red BBSC-2 Back Box Skirt, Ceiling, Red PC4W 4-Wire Horn Strobe, Standard cd, White Back Box Skirt, Ceiling, White TRC-HS Trim Ring, Ceiling, Red TRCW- Trim Ring, Ceiling, White HS Notes: * Add "-P' to model number for plain housing (no "FIRE" marking on Cover), e.g., P2R-P. t Add "-SP" to model number for "FUEGO" marking on Cover, e.g., P2R-SP. 1 "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 Candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 Candela settings. @2012 System Sensor _* uS')'57.EI!iV 3825 Ohio Avenue • St. Charles, IL 601 74 Product specifications subject tn change sathoutrrotice. Visit systernsensor.cn Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information, including the latest version of this data sheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0186 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177 *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert@ Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from —40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGHAUNG 0 0 @ FM USTED <~' S4011 (chimes, horn strobes, horns) APPROVED IVIEA a pproved 7300-1653:187 (outdOor Strobes) 7125-1653:188 (horn Strobes, chime stro bes) )sntdoor and alert Strobes) 3023572 M6A452-05-E 7135-1653:189 (horns, chimes) SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to d1ll holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 3%-inch top and bottom conduit entries and 3%-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7'W x 1.3"D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1 "W x 2.0" D (145 mm L x 130 mm W x 51 mm 0) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs F, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 Cd. AVDSO1 201 C 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 El High 135 Candela 150 Range 177 185 DC Input NA NA NA NA NA NA NA NA 8-17.5 Volts 15 15/75 228 246 281 286 207 220 251 258 16-33 Volts 15 Coded Medium Coded Low 15/75 30 75 44 51 56 40 46 52 95 110 69 50 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 6ndelal: 90 105 161 184 202 211 111Max.. ii DC Input :1 16-33 Volts 135 150 177 185 I31.!tI FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data W{Irr.i Horn Strobe s1TllJJilj 8-17.5 16-33 Switch Sound Volts Volts Position Pattern dB DC FWR DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal 7t Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AvDS01201 ut Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 Wall-Mount Horn Strobes erproof Back Box SpectrAlert Advance Diagrams Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information , Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-P' to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. I- Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 020 2 System Sensor, 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject without notice. visit systemsensor.conr SEILS'OR Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information, including the latest version of this data Sheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0187 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models SWK, SWHK, SCWK, SCWHK, SRK, SRHK, SCRK and SCRHK strobe lights intended for indoor or outdoor use and may be mounted on the wall or the ceiling. These strobe lights are suitable for outdoor use at an operating temperature range of -40°F to 150°F (-40°C to 66C)* rating and are NEMA 4X rated when used with the Listed models SA-WBB (wall), SA-WBBW (Wall) or the model SA-WBBC (ceiling), SA-WBBCW (Ceiling) weatherproof back boxes. May be followed by suffix -P for plain housing with no lettering. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDCIFWR INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for general signaling. For indoor or outdoor use. Refer to listee's is Installation Instruction Manual for details. NOTE: Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Corrected 07-22-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ZIVI operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DN-6935:D • H-202 FSP.851(A) Series NOTI FIER® Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan@ by Honeywell I General Notifier FSP-851(A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851T(A). The FS P-851 R(A) is remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851(A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication proto- col developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 3601 viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1' (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. - B501 (A): 4.1(10.4cm) diameter. - 113200S(A): 6.875' (17.46 cm) diameter. (r /) 6 FSP-851(A) in B2IOLP(A) Base - B200SR(A): 6.875' (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. - 8224B1(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851(A), 0°C to 49°C (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F). Low temperature signal for FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.54°C). FSP-851R(A) installed in a DNR(A)/DNRW, -20°C to 70°C (-4°F to 158°F). UL/ULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 ml mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at system sensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300pA @ 24VDC (one commu- nication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24 VDC ('ON"). Installation FSP-851(A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5' (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation r L DN-6935:D • 12/08/2011 - Page 1 of 2 S sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULListed:S1115. ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP-851TA). MEA Listed: 225-02-E. FM Approved. CSFM: 7272-0028:0206. Maryland State Fire Marshal: Permit # 2122. BSMI: C1313066760036. CCCF: Certif. # 2004081801000017 (FSP-8511) Certif. #2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/N FS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A" suffix indicates ULC Listed model. FSP-851: Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A: Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRAIDNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. 13200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces 6501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases. ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low- profile. F110BP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851 (A) only; box of 10. WCK-200B: White detector covers for use with FSP-851(A) only; box of 10. -Notifier@ and FlashScan® are registered trademarks of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so oo1 This document is not intended to be used for installation purposes. _____________ We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. W IlMUlN MANIMCIIUN All specifications are subject to change without notice. _ --------- Nei _ QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6935:1) • 12/08/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0206 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-851, FSP-851, FSP851R* and FSP-851T photoelectric type smoke detectors. Models FSP-751T and FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-751T, FAPT-751, FAPT-851, FSP-851, FSP-851 R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division dn-6936:al • H-211 nl!, b with FlashScan® by Honeywell 14*0000* .,' General FST-851 Series Intelligent Thermal (Heat) Detectors N OT I F I E R® Notifier FST-851 Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations. FST-851 Series thermal detectors use an innovative thermistor sensing circuit to produce 135°F! 57°C fixed-temperature (FST-851) and rate-of-rise thermal detection (FST-851 A) in a low-profile package. FST-851 H pro- vides fixed high-temperature detection at 190°F/880C. These thermal detectors provide effective, intelligent property protec- tion in a variety of applications. FST-851 Series detectors are compatible with all Notifier intelligent Fire Alarm Control Pan- els, except FireWarden series panels. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile, stylish design. • State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-851 R), 15°F (8.3°C) per minute. Factory preset at 135°F (57°C); high-temperature model at 190°F (88°C). Addressable by device. Compatible with FlashScan® and CLIP protocol systems. Direct dial entry of address 01-159 for FlashScan® loops, 01-99 CLIP mode loops. Two-wire SLC connection. Visible LEDs "blink" every time the unit is addressed. 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identifica- tion. • Remote test feature from the panel. • Built-in functional test switch activated by external magnet. • Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). • Low standby current. • Backward-compatible. • Built-in tamper-resistant feature. • Designed for direct-surface or electrical-box mounting. • Sealed against back pressure. • Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. SEMS screws for wiring of the separate base. 1110 • • Constructed of off-white Bayblend®, designed to commer- cial standards, and offers an attractive appearance. FST-851 Series in B7IOLP base 94-5V plastic flammability rating. Remote LED output connection to optional RA400Z remote LED annunciator. Optional sounder, relay, and isolator bases. Optional recessed (RMK400) or surface (SMK400E) base mounting kits. Specifications Size: 2.1' (5.3 cm) high x 4.1" (10.4 cm) diameter installed in B501 base, 6.1' (15.5 cm) diameter installed in B71OLP base. Shipping weight: 4.8 oz. (137 g). Operating temperature range: FST-851 Series, FST-851 R: - 20°C to 38°C (-4°F to 100°F); FST-851 H: -20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% - 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (880C). Altitude rating: 10,000 feet. ELECTRICAL SPECIFICATIONS: Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 300 pA @ 24 VDC (one com- munication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @ 24 VDC ("ON"). BASES A VAILABLE: B71OLP: 6.1" (15.5 cm) diameter. B501: 4.1' (10.4 cm) diameter. B501 BH-2 or B501 BHT-2: Sounder base assembly. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2' (15.748 cm) x 1.2' (3.048 cm). B224Bl Isolator Base: Dimensions: 6.2' (15.748 cm) x 1.2' (15.748 cm). Maximum: 25 devices between isolator bases. See Note 2 under Installation. Applications Use thermal detectors for protection of property. For further information, go to systemsensor.com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- dn-6936:al • 06/8/09 - Page 1 of 2 vides detailed information on detector spacing, placement, B501: Standard European flangeless base. zoning, wiring, and special applications. B501(A): Standard European flangeless base, ULC Listing. Installation BH5O1BH-2: Sounder base, includes B501 base above. The FST Series plug-in intelligent thermal detector uses a sep- BH501 BHT-2: Same as B501 BH-2, but includes temporal sounder. arate base to simplify installation, service, and maintenance. BH50IBHA: Sounder base, includes B501 base above Installation instructions are shipped with each detector. BH501 BHTA: Same as BH501BHA, but includes temporal sounder Mount base (all base types) on an electrical backbox which is at least 15° (3.81 cm) deep. Suitable boxes include: 4.0° (10.16 cm) square box. 3•5fl (8.89 cm) or 4.0' (10.16 cm) octagonal box. Single-gang box (except relay or isolator base). With B501BH-2 or B501 BHT-2 base, use a 4.0' (10.16 cm) square box. With B224RB or B224B1 base, use a 3.5° (8.89 cm) or 4.0° (10.16 cm) octagonal box, or a 4.0° (10.16 cm) square box. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S747 ULC Listed: S6978MEA Listed: 383-02-E FM Approved CSFM: 7270-0028:196 BSMI: C1313066760025 CCCF: Certif. #2004081801000018 U.S. Coast Guard: 161.002/23/3 (AFP-200); 161.002/27/3 (AFP1 O10/AM2020); 161.002/42/1 (NFS-640) Lloyd's Register: 03/60011 Product Line Information "A" suffix indicates ULC Listed model. FST-851: Intelligent thermal detector. Must be mounted to one of the bases listed below. FST-851 A: Same as FST-851 but with ULC Listing. FST-851 R: Intelligent thermal detector with rate-of-rise feature. FST-851 RA: Same as FST-851 R but with ULC Listing. FST-851H: Intelligent high-temperature thermal detector. FST-851HA: Same as FST-851H but with ULC Listing. BASES: B71OLP: Standard U.S. low-profile base B71OLPBP: Standard U.S. low-profile base, pkg. of 10. B71OLP: Standard U.S. low-profile base. B71OLP(A): Standard U.S. low-profile base. B501BP: Standard European flangeless base, pkg. of 10. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: F110: Retrofit replacement flange for older style high profile bases. Converts bases for use with FlashScan® detectors. RA400Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. Supported by B71OLPBP(A) and B501 (A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501 (A) base only. RMK400: Recessed mounting kit. For use with B501 (A) base only. SMB600: Surface mounting kit for use with B71OLPBP(A). BCK-200B: Black detector covers, box of 10. M02-04-00: Test magnet. M02-09-00: Test magnet with telescope stick. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. 155-127-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-ft. sections. Notifier® and FlashScan® are a registered trademark of Honeywell International Inc. Bayblend® is a registered trademark of Bayer Corp. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this docu- ment is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. H. We cannot cover all specific applications or anticipate all requirements. ENSINEEMNS A MANUFACTUMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-6936:al • 06/8/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0196 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FST-751, *851 *851 R, *..851 H (fixed temperature) and FST-751 R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for add tional detailed product description and operational considerations. RATING: *Models FST-751, -751 R, -851, and -851 R = 135°F fixed temperature *Model FST-851H = 190°F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Models B501 or B71OLP base (CSFM Listing No. 7300-0028:173) and separately listed compatable fire alarm control units. Refer to listee's Installation Instructions Manual for details. S *Rev. 2-04-2003KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct e11 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7300-1653:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, B404B, B404BT, B406B, B501, B501 B, 14506587-002, B501BH, B501 BHT, B401BH, 13110LP, 131IORLP, 131IORLP750, 131 121-P, B114LP, 13II4LPBT, B116LP and B2IOLP detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 S 06-17-05 61S4, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division df-50673:Rev • F-850 302 Series Rate-Anticipation Heat Detectors (2) Flre.uTeeALarms by Honeywell Iiitt1 I I The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation . The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8 (10.48 cm). Base diameter: 2' (5.08 cm). Electrical Ratings Voltage Current 6-125V0C 5amps 6-25VDC lamp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50 x 50 (15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. 1] 1271phol.jpg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-1 35/-194; 302-ET-135/-194; 302-135/-194) CSFM: 7270-0021:001 1271dia1.tit FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL 0.040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW OEVCON HERMETIC SEAL Cut-Away View dt-50673:flev • 02/03/09 - Page 1 of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-135 135°F All-Weather Vertical Mounting Note 2 below 302-AW-1 94 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-1 94 194°F All-Weather Vertical Mounting 302-EPM-1 35 135°F Explosion Proof Mounting Note 4 below 302-EPM-1 94 194°F Explosion Proof Mounting AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4" outlet box. NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50'x 50(15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to 'THIN" or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 112"(1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. S 1512009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINEEIIIIIII & MANUMCIURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-50673:Rev • 02/03/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION MW OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE . LISTING No. 7270-0021:0001 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Thermotech lnc.,2900 North 1000 West, Ogden, UT 84414 Contact: A. Mark Headley (801) 782-2233 Fax (801) 782-1746 Email: thermotechinc@hotmail.com DESIGN: Models 302, 302H, 302AW, 302ET and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-ET or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-ET and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. *Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct tIVI operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DN-6720:C • H-220 FMM.1(A), FMM-101(A), FZM-1(A) & FDM-1(A) 0 NOTI Fl ER Monitor Modules with FlashScan® by Honeywell General Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4 [10.16 cm] square box) that supervises either a Style D (Class or Style B (Class B) circuit of dry-contact input devices. FMM-1 01(A) is a miniature monitor module a mere 1.3 (3.302 cm) H x 2.75 (6.985 cm) W x 0.5 (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101 (A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises Compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FMM-1 (A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class T;ii -L cc FMM-1(A) (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICA TIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 cm) deep box. DN-6720:C • 10/06/2010 - Page 1 of 4 S F_ FMM-1 01(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. 14).,Q1 I_ ADDRESS I 0 1 137,\2 L - 2 711 4 LOOP I9 8 76 8 76 TENS ONES II IIi • oH 11w 0 o .jII IIj I3 -iII 110 I II co The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-1 01(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3 (3.302 cm) high x 2.75 (6.985 cm) wide x 0.65 (1.651 cm) deep. Wire length: 6 (15.24 cm) minimum. FZM-1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops, 01 - 99 on CLIP loops. LED flashes during normal operation; this is a programma- ble option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1 (A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICA TIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and 14): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 1.250 (3.175 cm) deep. Mounts to a 40 (10.16 cm) square x 2.125' (5.398 cm) deep box. Page 2 of 4— DN-6720:c • 10/06/2010 FDM I(A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM- 1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 320 to 120°F (00 to 490C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125° (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM- 1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation FMM-1 (A), FZM-1 (A), and FDM-1 (A) modules mount directly to a standard 4' (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:0219 MEA: 457-99-E U.S. Coast Guard: - 161.002/23/3 (AFP-200: FMM- 11-101, FZM- 1) - 161.002/42/1 (NFS-640: FMM- 11-101) Lloyd's Register: —03/60011/El (FMM-1I-101, FZM-1) - 94/60004/E2 (AFP-200: except FDM- 1) - 02/60007 (NFS -640: FDM-1) FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information NOTE: "A" suffix indicates ULC-fisted model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51253. DN-6720:C • 10/06/2010 - Page 3 of 4 DN-6724:B3 FCM-1(A) & FRM-1(A) NOTI Fl ERSeries (a Control and Relay Modules by Honeywell I . . General S FCM-1(A) Control Module: The FCM-1 (A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1 (A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handing Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (RN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FIashScanf.' releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1 (A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1 (A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM.1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3•2/17/2011 —Page 1 0f2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals 110 and Til): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 501N. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25' (31.75 mm) deep. Mounts to a 4' (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5' (114.3 mm) high x 4" (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4' (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM-1 (A) Current Maximum Load Application Rating Voltage Description 3A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded A .5 30 VDC Inductive Coded (LIR=5m5) 1A 30 VDC Inductive Coded (L/R=2m5) .3A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed mode!. FCM-1(A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. C13500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. S Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. U U "1 We cannot cover all specific applications or anticipate all requirements. 011111111EMINS & MMUFAC11NO All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - DN-6724:133 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ...... OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE - LISTING No. 7300-0028:0219 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP1O-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt TI4, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 637 hflavcli The InnovairFIex Series DNR and DNRW are intelligent (addressable) non-relay photoelectric duct smoke detectors. Like all InnovairFIex detectors, the DNR and DNRW both feature an adjustable housing design that fits square and rectangular installation footprints, mounts to both round and rectangular ductwork, and utilizes tool-free, plug-in sampling tubes for increased application flexibility and installation ease. These units sense smoke in challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). For even more extreme environments like rooftops, the DNRW's NEMA 4-rated watertight and UV-resistant housing protects against windblown dirt and dust, rain, and hose directed water, enabling it to be installed without a costly enclosure, saving time and money. The InnovairFIex housing cover isolates the sensor head from the low-flow feature for simple maintenance, and a cover tamper feature initiates a trouble signal for a removed or improperly installed sensor cover. The housing also provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module to meet specific application requirements. These detectors can be customized to meet local codes and specifications without additional wiring. SYSTEM $ SENSOR® Intelligent Non-Relay Photoelectric Duct Smoke Detector The lnnovairFlex'° Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features Photoelectric, integrated low-flow technology (detector head sold separately) Air velocity rating from 100 ft/min to 4,000 ft/mm Adjusts to square and rectangular mounting configurations Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented tool-free, plug-in sampling tubes New cover tamper signal Increased wiring space with a new 3/4-inch conduit knockout 'Housing has space for mounting a relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection UL 268A listed Remote testing capability Requires com line power only NEMA Type 4 UL listed for non-hazardous indoor and outdoor applications (DNRW only) UV-resistant, UL-listed housing and cover material (DNRW only) The InnovairElex line is compatible with all previous lnnovair models, including remote test accessories, for easy retrofits. WARNING: Duct smoke detectors have specific limitations. Agency Listings MSFM LISTED APPROVED approved 2911 3029700 3242-1653209/210 2125 S InnovairFIex Duct Smoke Detector Specifications Arch itectu ral/En gi nee ring Specifications . The air duct smoke detector shall be a System Sensor lnnovairFlex'°' DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA 4 Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints.The detector shall operate at air velocities of 100 ft/min to 4,000 ft/mm (0.5 m/sec to 20.32 m/sec).The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS1 51 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size: (Rectangular) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth (Square) 7,75 in (19.7 cm) Length; 9 in (22,9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA 4 (DNRW only) Operating Temperature Range: -4°F to 158°F (-20°C to 70°C) Storage Temperature Range: -22°F to 158°F (-30°C to 70° C) Operating Humidity Range: 0% to 95% relative humidity (non-condensing) Air Duct Velocity: 100 to 4,000 ft/mm (0.5 to 20.32 m/s) DCOIL (if included): 17.5- 26.4 VDC, 95 mA max Electrical Ratings Please see detector head installation manual for electrical specifications T Accessory1LCurrent 1ILoads a,t 24 VDC Device Standby Alarm RA100Z OmA 12mAMax. RTS151/RTS151KEY OmA 12mAMax. Installing the InnovairFiex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). A05-0422-035 Wiring for Intelligent Non-Relay Duct Smoke Detector• System wiring diagram for DNR: r — — i COMM LINE I I I I COMM. LINE (+) I I I I I I COMM. I I LINE(-) I I I I I I I I I I-----I UL/FM LISTED 1ST CONTROL DETECTOR PANEL IN LOOP DNR to RA100Z: +RA (+) Im _1 2ND DETECTOR IN LOOP RA100Z REMOTE ALARM LED OPTION 1 PER UNIT DNR to RTS151IRTS151 KEY with "R" Remote Test Capable Detector Head Option: TEST COIL + TEST COIL - RTS151/RTS151 KEY COMM+ OUT (CONV ONLY) + COMM— RA/RTS - . 2 [ ]___ :JUMPER RA+ 4 RTS+ DNR to RTS1 51/RTS151 KEY with DCOIL Option*: TEST COIL + TEST COIL -POWER EXTERNAL SUPPLY COMM+ © OUT (CONV ONLY) + Comm — J RTS151/RTS151 KEY REMOTE TEST STATION RNRTS - RA+ © LED OPTION 1 PER UNIT RTS + TEST COIL OPTION I PER UNIT 95 mA CURRENT DRAW *Important Notes The use of either the RTS1 51 01 RTS1 51 KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the DNR or DNRW installation manual for more information. The RTS1 51/RTS151 KEY test coil circuit requires an external 24 VDC power supply which must be UL listed. A05-0422-005 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. RTS151 UL S2522 RTS1S1 KEY ULS2522 RA100ZULS2522 S Orderina Information DNR Intelligent non-relay photoelectric low-flow duct smoke detector DNRW Watertight intelligent non-relay photoelectric low-flow duct smoke detector Accessories DCOIL Remote test coil required with ETX Metal exhaust tube duct width 1 ft (0.3 m) RS451/RTh451 KEY/RTS151/RTS151 KEY DST1 Metal sampling tube duct width up to 1 ft 0.3m) M02-04-00 Test magnet DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (03 to 0.6 m) RA100Z Remote annunciator alarm LED DST3 Metal sampling tube duct widths 2 ft to 4 f (0.6 to 1.2 m) RTS151 Remote test sta:ion DSTS Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) RTS1 51 KEY Remote test sta:ion with key lock DST1 0 Metal sampling tube duct widths 8 ft to 12 It (2.4 to 3.7 m) DH4000E-1 Weatherproof enclosure P48-21-00 End cap for metal sampling tubes . SYSTEM SENSOR 02010 System Sensor 3825 Ohio Avenue. St. Charles, IL 60174 Product specifications ~bje Phone: 800-SENSOR2 . Fax: 630-377-6495 cUrrentprOdutiwrmanOwndUthng1htes1VeronolthisdataShee1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1653:0209 Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. [] S *Rev. 03-23-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: MDdels RTS1 51, RTS1 51 KEY and RA1 OOZ Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. S 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division