HomeMy WebLinkAbout3820 PIO PICO DR; ; FA160032; Permit9/27/22,11:20 AM FA160032 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 3820 PlO PICO DR Permit Type: FALARM Parcel No: Lot #: 0 Reference No.: Permit No: FA160032 Status: ISSUED Applied 6/6/2016 Approved: 8/1/2016 Issued: 8/1/2016 PC #: Inspector: Project Title: ST. PATRICK'S PARISH SCHOOL INSTALL NEW FULLY AUTOMATIC VOICE FIRE ALARM SYSTEM TO SERVE ST. PATRICK CLASSROOM BLDG, BUILDING M & ADMIN BLDG. POWER LIMITED ADDRESSABLE FIRE ALARM SYSTEM WITH VOICE EVAC, OPEN PLENUM CABLE (SPLINE) & CONDUIT (POLYLINE) CIRCUITS - INITIATING: ADDRESSABLE, CLASS B NOTIFICATION: CLASS B. STYLE Y Applicant: LOW VOLTAGE FIRE INC STE L 1930 WATSON WY VISTA CA 760-598-4110 Owner: Fees ($) 1 Add'l Fees ($) Balance 564.5 Total ($) ($) 0 564.5 0 about:blank 1/1 1 , • FIRE ALARM SYSTEM SUBMITTAL L wItcg in t g r i t4a cl $ y s t rn s FIRE ALARMS SOUND • DATA S MEDIA S SECURITY* CCTV S ACCESS CONTROL ST. PATRICK PARISH SCHOOL 3820 PlO PICO DRIVE, CARLSBAD, CA 92008 LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1930 WATSON WAY, STE L VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: CIO, C16 # 791832 .' FAl 60032 3820 PlO PICO DR S LavJVàIta nPegratoc sy s tems- PHONE: (760) 598-4110 FAX: (760)598-4107 PART DESCRIPTION MANUFACTURER CSFM LISTING NFS2-640 FIRE ALARM CONTROL PANEL W/ VOICE NOTIFIER 7165-0028:0224 UDACT - 2 UNIVERSAL DIGITAL ALARM COMMUNICATOR TRANSMITTER NOTIFIER 7165-0028:0224 DVC-EM DIGITAL VOICE CONTROL BOARD NOTIFIER 7165-0028:0224 DVC-KD KEYPAD VOICE CONTROL NOTIFIER 7165-0028:0224 DS-DB DIGITAL DISTRIBUTION BOARD NOTIFIER 7165-0028:0224 DS-AMP AMPLIFIER, 125 WATTS NOTIFIER 7165-0028:0224 RM-ISA REMOTE MICROPHONE NOTIFIER 7165-0028:0224 FDU-80 REMOTE ANNUNCIATOR NOTIFIER 7165-0028:0136 CELLCOMSLCF CELL DIALER DMP 7300-1157:0136 SPSON SPEAKER STROBE @ CEILING SYSTEM SENSOR 7320-1653:0201 SPS\NK OUTDOOR SPEAKER STROBE @WALL SYSTEM SENSOR 7320-1653:0201 SRNK OUTDOOR SPEAKER @WALL SYSTEM SENSOR 7320-1653:0201 SPCN SPEAKER © CEILING SYSTEM SENSOR 7320-1653:0201 SCW STROBE @ CEILING SYSTEM SENSOR 7125:1653:0186 S\NK OUTDOOR STROBE @WALL SYSTEM SENSOR 7300-1653:0187 FSP-851 SMOKE DETECTOR NOTIFIER 7272:0028:0206 FST-851 HEAT DETECTOR NOTIFIER 7270:0028:0196 B21OLP SMOKE/ HEAT BASE SYSTEM SENSOR 7300-1653:0109 302-ET-165 OUTDOOR HEAT DETECTOR NOTIFIER 7270-0021:0001 FMM-101 MINI MONITOR MODULE NOTIFIER 7300-0028:0219 FOM-1 DUAL MONITOR MODULE NOTIFIER 7300-0028:0219 FMM-1 MONITOR MODULE NOTIFIER 7300-0028:0219 FRM-1 RELAY MODULE NOTIFIER 7300-0028:0219 DNR DUCT DETECTOR(BY OTHERS) SYSTEM SENSOR 3242-1653:0209 RTS-151 REMOTE TEST SWITCH SYSTEM SENSOR 7300-1653:0212 5SU00672 DOCUMENT CABINET FDB N/A Low Voltage Integrated Systems, Inc. 1930 Watson Way, Ste L • Vista, California 92081 FIRE • SECURITY • CCTV • ACCESS CONTROL • SOUND • MEDIA LICENSE NO. C10, C16#791832 DN-7111:I•A-13 14 I[à1iIiJI4i Fire Alarm System . Honeywell II Intelligent Fire Alarm Coitr 1 Panels N FS2-640( E) Intelliaent Addressable fl The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series prod- ucts meet virtually every application requirement. The NFS2-640's modular design makes system planning eas- ier. The panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. A host of other options are available, including single- or multi- channel voice; firefighter's telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection prod- ucts for challenging environments, and many additional options. NOTE: Unless called out with a version-specific "E" at the end of the part number, "NFS2-640" refers to models NFS2-640 and NFS2-640E; similarly, "CPU2-640" refers to models CPU2-640 and CPU2-640E. Features Certified for seismic applications when used with the appro- priate seismic mounting kit. Approved for Marine applications when used with listed compatible equipment. See DN-60688. One, expandable to two, isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7. Up to 159 detectors (any mix of ion, photo, thermal, or multi-sensor) and 159 modules (Addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay) per SLC. 318 devices per loop/636 per FACP or network node. Standard 80-character display, 640-character large display (NCA-2), or display-less (a node on a network). Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging. 6.0 A switch mode power supply with four Class A/B built-in Notification Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. Autoprogramming and Walk Test reports. Multiple central station communication options: - Standard UDACT - Internet - Internet/GSM 80-character remote annunciators (up to 32). NFS2-640 EIA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column orinters). History file with 800-event capacity in nonvDlatile memory, plus separate 200-event alarm-only file. Alarm Verification selection per point, with automatic counter. Presignal/Positive Alarm Sequence (PAS). Silence innibit and Auto Silence timer option5. March time/temporal/California two-stage coding/strobe synchronization. Field-programmable on panel or on PC, With VeriFire Tools program check, compare, simulate. Full QWERTY keypad. Battery charger supports 18 —200 AH batteiies. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Automatic time control functions, with holiday exceptions. Surface Mount Technology (SMT) electronics. Extensive, built-in transient protection. Powerful Boolean logic equations. Support for SCS Series smoke control system in HVAC mode. DN-71 11:1 • 12/20/2013 - Page 1 of 8 Up to 32 remote displays jIIII[IrLi FDU-80 LCD2-80 EIA-485 \K O ii:Plaj4 NCA-2 OR with no display FSC-851 IntelliQuad FAPT-851 Acclimate PLUS F L-751 FlashScan VIEW FSP-851 Photo FSI-851 Ion FST-851 Thermal FSA-8000 etc. ElA-485 NCA-2 AS PRIMARY DISPLAY Backlit, 640-character display. Supports SCS Series smoke control system in FSCS mode when SCS is connected to the NCA-2 used as primary display. Supports DVC digital audio loop. Printer and CRT EIA-232 ports. EIA-485 annunciator and terminal mode ports. Alarm, Trouble, Supervisory, and Security relays. FLASHSCAN® INTELLIGENT FEATURES Polls up to 318 devices in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - up to nine levels. Pre-alarm ONYX intelligent sensing - up to nine levels. Day/Night automatic sensitivity adjustment. Sensitivity windows: - Ion - 0.5 to 2.50/6/foot obscuration. - Photo - 0.5 to 2.350/6/foot obscuration. - Laser (VIEW®) - 0.02 to 2.00/6/foot obscuration. - Acclimate PIuSTM - 0.5 to 4.0%/foot obscuration. - InteIliQuadTM - 1.0 to 4.00/o/foot obscuration. - IntelIiQuadTM PLUS - 1.0 to 4.0%/foot obscuration Drift compensation (U.S. Patent 5,764,142). Degraded mode - in the unlikely event that the CPU2-640 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. FSL-751 (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the fire location. Early warning performance comparable to the best aspira- tion systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. Low-temperature warning signal at 40°F ± 5°F (4.44°C ± 2.77°C). SLC IntIligent Loop I DEVICES -iUil' ! NBG-12LX ,j. XP6I10 I/O Modules FMM-1 I FCM-1 IDC 4, NAC FRM-1 Relay Contact SLC Intel/bent Loo.o 2 2048 annunciator/control points iIi InN L±L ACM-8R ACM/AEM 24AT LDM-32 Relay Control LED Annunciator Custom Graphics Dual phone 01 lines to Optional 636-point UDACT Central Station Sample NFS2-640 System "C" cabinet size shown Options PRN 7111blok-2013.wmf Page 2o18— DN-7111:I • 12/20/2013 FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. FSA -8000 INTELLIGENT FAAST DETECTOR Connects directly to the SLG loop of compatible ONYX series panels Provides five event thresholds that can be individually pro- grammed with descriptive labels for control-by-event pro- gramming; uses five detector addresses. Uses patented particle separator and field-replaceable filter to remove contaminants. Advanced algorithms reject common nuisance conditions FCO-851 INTELLIQUADTN PLUS ADVANCED MULTI-CRITERIA FIRdCO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4 (CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). Low-pressure G02 listed. DIGITAL VOICE AND TELEPHONE FEATURES Up to eight channels of digital audio. 35, 50, 75, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series; NGA-2 required as primary display). Solid-state digital message generation. Firefighter telephone option. 30- to 120-watt high-efficiency amplifiers (AA Series). Backup tone generator and amplifier option. NFS2-640 can also integrate with the FirstGommand Emer- gency Communications System. See DN-60772. HIGH-EFFICIENCY OFFLINE SWITCHING 3.0A POWER SUPPLY (6.0A IN ALARM) 120 VAC (NFS2-640); 240 VAC (NFS2-640E). Displays battery current/voltage on panel (with display). FlashScan, Exclusive World-Leading Detector Protocol At the heart of the NFS2-640 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashS- can is an all-digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS2-640 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS2-640 with industry-leading smoke detection capabil- ity. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high-speed microcomputer used by the NFS2-640. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control func- tions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature. The FAGP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installa- tion, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS2-640, like all NOTIFIER intelligent panels, has the exclusive feature of pro- gram creation and editing capability from the front panel key- pad, while continuing to provide fire protection. The architecture of the NFS2-640 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per-point segments, while the NFS2-640 simulta- neously monitors other (already installed) points for alarm con- ditions. VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Win- dows®-based and provides technologically advanced capabili- ties to aid the installer. The installer may create the entire program for the NFS2-640 in the comfort of the office, test it, DN-711 1:1 • 12/20/2013 - Page 3 of 8 [I store a backup file, then bring it to the site and download from a laptop into the panel. Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS2-640's flexible sys- tem design. Rows: The first row of equipment in the cabinet mounts in the chassis shipped with the FACP. Mount the second, third, or fourth rows of equipment in a CHS-4 series chassis or, for Dig- ital Voice Command products, in CA-1 or CA-2. (For DVC-EM and DAA2/DAX components see DVC Manual; for DS series components see DS-AMP Manual; for DVC-AO applications, see AA Series Installation Manual). Other options are avail- able; see your panel's installation manual. Wiring: When designing the cabinet layout, consider separa- tion of power-limited and non-power-limited wiring as dis- cussed in the NFS2-640 Installation Manual. Positions: A chassis offers four basic side-by-side positions for components; the number of modules that can be mounted in each position depends on the chassis model and the size of the individual module. There are a variety of standoffs and hardware items available for different combinations and config- urations of components. It is critical that all mounting holes of the NFS2-640 are secured with a screw or standoff to ensure continuity of Earth Ground. Layers: The control panel's chassis accepts four layers of equipment, including the control panel. The CPU2-640 fills three positions (left to right) in the first-installed layer (the back of the chassis); its integral power supply occupies the center two positions in the next two layers; the optional display occu- pies (the left) two positions at the front, flush with the door. Some equipment, such as the NCA-2, may be mounted in the dress panel directly in front of the control panel. The NCA-2 can be used as a primary display for the NFS2-640 (use NCA/ 640-2-KIT) by directly connecting their network ports (required in Canadian stand-alone applications); see NCA-2 data sheet for mounting options (DN-7047). Expansion: Installing an LEM-320 Loop Expander Module adds a second SLC loop to the control panel. The LEM-320 is mounted onto the CPU2-640, occupying the middle-right, sec- ond (back) slot on the chassis. Networking: If networking two or more control panels, each unit requires a Network Communication Module or High- Speed Network Communication Module. (HS-NCM can sup- port two nodes; see "Networking Options" on page 5). These modules can be installed in any option board position (see manual), and additional option boards can be mounted in front of the network communication modules. KDM-R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout, figure). 12 LED indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled; Control Active; Abort; Pre-Discharge; Discharge. Keypad Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED backlight. Product Line Information "Configuration Guidelines" on page 4 "Networking Options" on page 5 "Auxiliary Power Supplies and Batteries" on page 5 "Audio Options" on page 5 "Compatible Devices, EIA-232 Ports" on page 5 "Compatible Devices, EIA-485 Ports" on page 5 "Compatible Intelligent Devices" on page 6 "Enclosures, Chassis, and Dress Plates" on page 6 "Other Options" on page 7 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On systems with one FACP (one CPU2-640/-640E), display options are the KDM-R2 or the NCA-2. On network systems (two or more networked fire panel nodes), at least one NCA-2, NCS, or ONYX Works annunciation device is required. Other options listed as follows; KDM-R2: 80-character backlit LCD display with QWERTY pro- gramming and control keypad. Order two BMP-i blank mod- ules and DP-D15P2 mounting plate separately. Requires top row of a cabinet. Required for each stand-alone 80-character display system. The KDM-R2 may mount in network nodes. to display "local" node information as long as at least one NCA-2 or NCS/ONYX Works network display is on the system to dis- play network information. (Non-English versions also available: KDM-R2-FR, KDM-R2-PO, KDM-R2-SP.) NCA-2: Network Control Annunciator, 640 characters. On sin- gle CPU2-640/-640E systems, the optional NCA-2 can be used as the Primary Display for the panel and connects directly to the CPU2-640/-640E. On network systems (two or more networked fire panel nodes), one network display (either NCA-2 or NCS/ONYX Works) is required for every system. On network systems, the NCA-2 connects to (and requires) a standard Network Communication Module or High-Speed Net- work Communication Module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP-D15P2, ADP-48, or in an annunciator box, such as the ABS-213. In CAB-4 top-row applications, a DP-D15P2 and two BMP-1 blank modules are required for mounting. Required for NFS2-640 applications employing the DVC-EM with DAL devices. Non-English versions are available. For marine appli- cations, order NCA-2-M; for non-English Marine applications, order NCA-2-M and the appropriate KP-KIT-XX. See DN-7047. NCAI640-2-KIT: Bracket installation kit required to mount NCA-2 to the CPU2-640/-640E's standard chassis. DP-DISP2: Dress panel for top row in cabinet with CPU2-640/ 640E installed. ADP2-640: Dress panel for middle rows with CPU2-640/640E. BMP-1: Blank module for unused module positions. 13132-4: Battery plate, required. LEM-320: Loop Expander Module. Expands each NFS2-640 to two Signaling Line Circuits. See DN-6881. CPU2-640: Central processing unit (CPU) with integral 3.0 A (6.0 A in alarm) power supply for an NFS2-640 system. Includes control panel factory-mounted on a chassis; one Sig- naling Line Circuit expandable to two; documentation kit. Order one per system or as necessary (up to 103 network nodes) on a network system. (Non-Engilsh versions also avail- able: CPU2-640-FR, CPU2-640-PO, CPU2-640-SP) CPU2-640E: Same as CPU2-640 but requires 240 VAC, 1.5 A, see (3.0 A in alarm). (Non-English versions also available: CPU2- 640E-PO, CPU2-640E-SR) Page 4ot8— DN-7111:1 • 12/20/2013 NETWORKING OPTIONS NCM-W, NCM-F: Standard Network Communications Mod- ules. Wire and multi-mode fiber versions available. See DN- 6861. HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed Network Communications Modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conver- sion models are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN- 6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part num- bers. NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN- GW-EM.) See DN-60499. NWS-3: NOTl.FlRE.NEPM Web Server. See DN-6928. CAP-GW: Common Alerting Protocol Gateway. See ON- 60576. VESDA-HLl-GW: VESDAnet high-level interface gateway. See DN-60753. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOTI•FlRE•NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See DN-60679. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 A or 10.0 A addressable charging power sup- ply. See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and \ transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. FCPS-24S6/S8: Remote 6 A and 8 A power supplies with bat- tery charger. See DN-6927. BAT Series: Batteries. NFS2-640 uses two 12 volt, 18 to 200 AH batteries. See DN-6933. AUDIO OPTIONS N NOTE: For mounting hardware, see "Enclosures, Chassis, and Dress Plates" on page 6 and peripheral data sheets. DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. Capable of playing up to eight simultaneous messages when used with Digital Audio Loop (DAL) devices. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display. See DN- 60726. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC-EM while retaining digital audio distribuition capabilities. Can be configured with up to four DS- AMPs, supplying high-level risers spread throughout an instal- lation. See DN-60565. DVC-KD: DVC-EM keypad for local annunciation and controls; \ status LEDs and 24 user-programmable buttons. See ON- 7045. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-RFM, OS-FM, DS-SFM: Fiber conversion modules for DVC-EM, DS-DB distribution board, and DAX and DAA2 Series amplifiers. See DN-60633. DVC-AO: DVC Analog Output board provides four analog out- put circuits for use with AA Series amplifiers. Four-channel operation supported. See DN-7045. DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- bly with power supply; includes chassis. See DN-60556. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See ON-60561. OAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. TELH-1: Firefighter's Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis. See DN-7045. CMIC-1: Optional microphone and microphone well assembly used with the CA-1 chassis. RM-1/RM-1SA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) stand-alone cabinets. See DN-6 728. AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier and audio input supervision, backup input, and automatic swi- tchover, power supply, cables. See DN-3224. AA-120/AA-100: Audio Amplifier provides up to 120 watts of 25 yAMS audio power for the NFS-640. The amplifier contains an integral chassis for mounting to a CAB-134, -C4, or -D4 backbox (consumes one row). Switch-mode power. Includes audio input and amplified output supervision, backup input, and automatic switchover to backup tone. Order the AA-100 for 70.7 yAMs systems and 100 watts of power. See DN-3224. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC-EM systems running SR4.0. For specific information on DAA-50 series amplifiers, refer to DN-7046. For information on DAA-7525 Series, refer to DN-60257. NFC-25/50: 25 watt, 25 VRMS, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, digital message generator, and single-/dual-channel Class A or Class B speaker circuits. See DN-60772. COMPATIBLE DEWCES, EIA -232 PORTS PRN-6: 80-column printer. See DN-6956. VS4095/5: Printer, 40-column, 24V. Mounted in external back- box. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See ON-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. DN-7111:I • 12/20/2013- Page 501 8 ACM-48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active! Alarm LEDs can be programmed (by powered-up switch selec- tion) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. F131.1-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FSL-751: FlashScan VIEW laser photo detector. See ON- 6886. DNR: InnovairFIex low-flow non-relay duct-detector housing (order FSP-851 R separately). Replaces FSD-751 PL/FSD- 751 RPL. See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. B224B1: Isolator base for low-profile detectors. See ON- 60054. B21OLP: Low-profile base. Standard U.S. style. Replaces 071fl1 D o flkl CnnCA Ll I-ALA-'. See UN-620. LCD2-80: Terminal and ACS mode. 80-character, backlit LC European-style, 4" (10.16 cm) base. See DN-60054. display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 B200S: Intelligent programmable sounder base, capable of per FACP. See ON-60548. producing a variety of tone patterns including ANSI Temporal LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM- 3. Compatible with sychronization protocol. See DN-60054. R32; remote custom graphic driver modules. See DN0551. B200SCOA: Based on B200SA, with added CO detector SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers markings in English/French. For Canadian applications only. SCS-8L, SCE-8L; eight (expandable to 16) circuits (HVAC B200SR: Sounder base, Temporal 3 or Continuous tone. See only). See ON-4818. '\ON -60054. TM-4: Transmitter Module. Includes three reverse-polarity cir- FMM-1: FlashScan monitor module. See ON-6 720.. cults and one municipal box circuit. Mounts in panel module position (single-address-style) or in Cl-1S2-M2 position. See DN-6860. FDM-1: FlashScan dual monitor module. See DN-6 720.. FZM-1: FlashScan two-wire detector monitor module. See ON- UDACT-2: Universal Digital Alarm Communicator Transmitter,° 6720.. 636 channel. See ON-60686. FMM-101: FlashScan miniature monitor module. See ON- UZC-256: Programmable Universal Zone Coder provides pos- 6720. itive non-interfering successive zone coding. Microprocessor- FTM-1: Firephone Telephone Module connects a remote fire- controlled, field-programmable from IBM®-compatible PCs fighter telephone to a centralized telephone console. Reports (requires optional programming kit). Up to 256 programmable status to panel. Wiring to jacks and handsets is supervised. codes. Mounts in BB-UZC or other compatible chassis (pur-'\See DN-6989. chased separately). See ON-3404. CM-i: FlashScan control module. See DN-6 720.. FCM-1-REL: FlashScan releasing control module. See DN- FSA-8000: Intelligent FAAST Fire Alarm Aspiration Sensing 60390. Technology®. Intelligent aspirating smoke detector. For Cana- FRM-1: FlashScan relay module. See DN-6720.. than applications, order FSA-8000A. See DN-60792. FDRM-1: FlashScan dual monitor/dual relay module. See ON- 60709. FSB-200S: Intelligent beam smoke detector with integral sen- NBG-12LX: Manual pull station, addressable. See ON-6726.. sitivity test. See DN-6985. ISO-X: Isolator module. See ON-2243. See ON-2243. FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria XP6-C: FlashScan six-circuit supervised control module. See Detector. See DN-604 12. DN-6924. X1126-MA: FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See ON-6926. XP10-1111: FlashScan ten-input monitor module. See DN-6923 FSP-851T: FSP-851 plus dual electronic thermistors that add 135°F (57°C) fixed-temperature thermal sensing. See ON- SLC-IM: SLC integration module, for VESDAnet detectors. See DN-60755. 6935. FSP-851 R: FSP-851, remote-test capable. For use wit"ENCLOSURES, CHASSIS, AND DRESS PLATES DNR(W). See DN-6935. CAB-4 Series Enclosure: NFS2-640 mounts in a standard FST-851: FlashScan thermal detector 135°F (57°C). See DN- CAB-4 Series enclosure (available in four sizes, A" through 6936. °D"). Backbox and door ordered seperately; requires BP2-4 FST-851R: FlashScan thermal detector 135°F (57°C) with battery plate. A trim ring option is available for semi-flush mounting. See ON-6857. rate-of-rise. See ON-6936. FST-851 H: FlashScan 190°F (88°C) high-temperature thermal EQ Series Cabinets: EQ series cabinets will house amplifiers, detector. See ON-6936. power supplies, battery chargers and control modules. EQ cabinets are available in three sizes, "B" through "D". See ON- FAPT-851: FlashScan Acclimate Plus low-profile multi-sensor 60229.. detector. See DN-6937. Page 6ot 8- DN-711 1:1 • 12/20/2013 COMPATIBLE INTELLIGENT DEVICES FSB-200: Intelligent beam smoke detector. See DN-6985. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite- ria Fire/CO Detector. See DN-60689. \ FSI-851: Low-profile FlashScan ionization detector. See ON- 6934. FSP-851: Low-profile FlashScan photoelectric detector. See ON-6935. CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see DN-60688. CHS-4: Chassis for mounting up to four APS-6Rs. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers or one AMG-E and one AA-30. DP-1B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBR: Same as above but red. CHS-BH1: Battery chassis; holds two 12.0 AH batteries. Mounts one the left side of DAA2 chassis. See DN-7046. CA-11: Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC-EM and a DVC-KD (optional); and the right side houses a CMIC-i microphone and its well (optional). See DN-7045. CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC-EM mounted on a half-chassis and one NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMlC-i microphone. ADDR Series doors with two-tier visibility are available for use with the CA-2 config- uration: ADDR-134, ADDR-C4, ADDR-D4 (below). CFFT-1: Chassis to mount firefighter's telephone and one ACS annunciator in a CAB-4 row. Includes TELH-i firefighter's handset for the DVC-EM, chassis, phone well and mounting hardware. Order DP-CFFT dress panel separately. DP-CFFT: CFFT1 dress panel. Requires BMP-i if no ACS annunciator is installed. ADDR.B4*: Two-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-134. See DN-7045, DN-6857. ADDR-CV: Three-tier-sized door, designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045, DN-6857. ADDR.D4*: Four-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-7045, DN-6857. "Use ADDR-B4/C4/04 when CA-2 chassis is installed in top two rows with NCA-2 or BP-CA2. Use standard door when CA- 2 is not installed in top two rows. For additional configuration information, see the DVC application guide on http://esd.noti- fier.com. DPA-1: Dress panel, used with the CA-1 chassis when config- ured with a DVC-EM, DVC-KD, and CMlC-1. See DN-7045. DPA-2B: Dress panel used with CA-2 chassis assembly. VP-2B: Dress panel, required when CA-2 chassis is installed in the top two cabinet rows. DPA-1A4: Dress panel, used with the CA-1 chassis when the CM IC-11 is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. See DN- 7045. . BP-CA2: Blank plate for CA-2 chassis. BB-UZC: Backbox for housing the UZC-256 in applications where the UZC-256 will not fit in panel enclosure. Black; for red, order BB-UZC-R. SEISKIT-CAB: Seismic mounting kit. Required for seismic- certified applications with NFS2-640 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two 26 AH batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AK batteries. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 411UDAC: Digital alarm communicator. See DN-6746. IPDACT-212UD, IPDACT Internet Monitoring Module: Con- nects to primary and secondary DACT telephone output ports for internet communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPCHSKlT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: Y-adapter option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red. For Black order IPENC-B. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tor. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. For Canadian applications order I PGSM-4GC. See DH-60769. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. System Specifications SYSTEM CAPACITY Intelligent Signaling Line Circuits ............1 expandable to 2 Intelligent detectors .........................................159 per loop Addressable monitor/control modules..............159 per loop Programmable software zones.........................................99 Special programming zones.............................................14 LCD annunciators per CPU2-640/-640E and NCA-2 (observe power).............................................32 ACS annunciators per CPU2-640/-640E .......................... 32 addresses x 64 points ACS annunciators per NCA-2 .................................. 32 addresses x 64 or 96 points NOTE: The NCA-2 supports up to 96 annunciator address points per ACM-24AT/-48A. ELECTRICAL SPECIFICATIONS Primary input power: - CPU2-640 board: 120 VAC, 50/60 Hz, 5.0 A. - CPU2-640E board: 220/240 VAC, 50/60 Hz, 2.5 A. Current draw (standby/alarm): - CPU2-640(E) board: 0.250 A. Add 0.035 A for each NAC in use. - KDM-R2: 0.100 A. - LEM-320: 0.100 A. DN-7111:I • 12/20/2013— Page 70f8 S Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 A. of available power. This is shared by all internal circuits. See Installation Manual for a complete current draw calculation sheet. Standard notification circuits (4): 1.5 A each. Resettable regulated 24V power: 1.25 A. Two non-resettable regulated 24V power outputs: —1.25 A. —0.50 A. Non-resettable 5V power: 0.15A. Battery charger range: 18 AH —200 AH. Use separate cab- inet for batteries over 26 AH. Float rate: 27.6 V. CABINET SPECIFICATIONS Systems can be installed in CAB-4 Series cabinets (four sizes with various door options, see DN-6857). Requires BP2-4 Battery Plate. SHIPPING WEIGHT CPU2-640/-640: 14.3 lb (6.49 kg). CPU2-640/-640E: 14.55 lb (6.60 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 491C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic NFS2-640 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S635. ULC Listed: S635. FM Approved. MEA: 128-07-E. FDNY: COA#6085, #6121. CSFM: 7165-0028:0243. City of Chicago. City and County of Denver. CCCF listed. Marine Applications: Marine approved systems must be con- figured using components itemized in this document. (See Main System Components, in "Product Line Information.) Spe- cific connections and requirements for those components are described in the installation document, PN 54756. When these requirements are followed, systems are approved by the fol- lowing agencies: US Coast Guard 161.002/50/0, 161.002/55/0 (Standard 46 CFR and 161 .002). Lloyd's Register 11/600013 (ENV 3 category). American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. STANDARDS The NFS2-640 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: UL 864, 9th Edition (Fire). UL 1076 (Burglary). UL 2572 (Mass Notification Systems). LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual and Waterflow). Not applicable for FM. EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- work). IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- mic). CBC 2007 (Seismic). NOTI.FIRE•NETTM, InteIIlQuadTM, and ONYXWorksTM are trademarks; and Acclimate® PlusTM, FirstCommand®, FlashScan®, NOTIFIER®, ONYX®, VerlFire®, and VIEW® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. IBM® is a registered trademark of IBM Corporation. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. [1 This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. _________________ I I I I All specifications are subject to change without notice. I I QUALITY SYSTEMS Made in the u.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 8 of 8— DN-711 1:1 • 12/20/2013 DN-69330 • E-205 BAT Series Batteries Sealed Lead-Acid General BAT Series Batteries are Power-Sonic brand batteries. BAT Series (or Power-Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features Provide secondary power for control panels. Sealed and maintenance-free. Overcharge protected. Easy handling with leak-proof construction. Ruggedly constructed, high-impact case (ABS). NOTIFIER® by Honeywell 6933c0vjpg Li Long service life. Ordering Information Compact design. BAT-1250-BP: 10-unit bulk pack of BAT-1250 (12 V 5 AH). Agency Listings and Approvals BAT-1270-BP: 5-unit bulk pack of BAT-1270 (12 V 7 AH). BAT-12120-BP: 4-unit bulk pack of BAT-12120 (12V 12 AH). The listings and approvals below apply to BAT Series Batter- ies. In some cases, certain modules may not be listed by cer- BAT-12180-BP: 2-unit bulk pack of BAT-12180 (12 V 18 AH). tain approval agencies, or listing may be in process. Conswt 11 BAT-12260-BP: 2-unit bulk pack of BAT-12260 (12 V 26 AH). factory for latest listing status. BAT-12550: single battery (12 V 55 AH). UL Recognized Components: MH20845 (Power-Sonic). BAT-121 000: single battery (12 V 100 AH). Part Number Reference & Specifications Part Number Power- Sonic Part Number Battery Description DIMENSIONS ______ Nominal Voltage Nominal Capacity @20hr. rate A.H. Width _______ Depth Height Height over terminal Weight in. mm in. mm in. mm in. mm lb. kg. BAT-1 250 PS-1250 12 5 sealed 3.54 90 2.76 70 3.98 11 4.21 iT•3.50 rr BAT-1 270 PS-1270 12 7 sealed 595 151 256 65 31 94 36 98 4.8 2.18 BAT-12120 PS-12120 12 12 sealed 595 151 36 98 31 94 3.94 100 7.92 39 BAT-12180 PS-12180 12 18 sealed 713 181 300 76 6.59 167 6.59 167 12 512 BAT-1 2260 PS-12260 12 26 sealed 65 167 697 177 492 125 42 125 17 711 BAT-1 2550 PS-12550 12 55 1 sealed 19.04 230 545 138 815 207 8.98 1228 36 BAT-121000 P5-121000 12 100 Isealed 112 305 6.6 1168 815 207 898 228 68 3084 I DN-6933:D.02/28/2013—Page 1 of 2 Effect of Temperature on Capacity 120 110 20 0 -40 -30 -20 -10 0 10 20 30 40 50 60 Temperature rci 0.05 C 0.10 C 0.25 C 0.50 C l's S Discharge Characteristic Curves at 20°C (68°F) For 6V For 12V Battery Battery 5.513.0. ..- . 6.5 12.0 6.5 11.0 5.0 10.0 E 4.5 9.0 4.0 6.0 1 2 4 6 8 10 20 40 60 2 4 6 910 20 Minutes Hours -.--- - Discharge Time PS-121000 Shelf-Life and Storage 100% of capzs~ to restore full city U 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) PS-121000 Discharge Characteristics 14.0 13.0 H 1.2 2.4 6 12 24 36481 2 4 6 810 20 40 inn °I-' h Discharge Time NOTIFIER® is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. 02013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 111111113111111 MPAUFACT11111111 All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6933:D • 02/28/2013 100 0 cc 80 C 0 C e 60 6t 40 cc 0. Al . - t . .;. liii IIIlIIIiP!millml UIilIUIJ!i1IIII iiu•iiii ••iiti•ii••uui•i U DACT-2 Universal Digital Alarm Communicator Transmitter General The Universal Digital Alarm Communicator Transmitter (UDACT- 2) is designed for use on Notifier Fire Alarm Control Panels and on the NCA-2 Network Control Annunciator. When used in con- junction with the NCA-2 network control annunciator, the UDACT-2 can report the status of all control panels on NOTI.FIRE.NETTM. The UDACT-2 transmits system status to UL listed Central Station Receivers via the public switched tele- phone network. The UDACT-2 can be installed in the panel cab- inet or remotely in a separate enclosure. NOTE: The UDACT-2 can also be used with legacy panels. Please refer to the UDACT-2 manual for more information. The UDACT-2 upload/download programming and firmware updates are accomplished with VeriFire Tools. Refer to the Pro- gramming Section for further details. The UDACT-2 is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT-2 is capable of transmitting all of the zone and point sta- tus associated with each panel. When the UDACT-2 is used with the NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Report- ing may be in the form of points or zones (refer to the UDACT-2 manual for specific reporting parameters). Points transmitted may be programmed for a variety of types, including fire, water- flow, supervisory, etc. NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features Programmable with VeriFire Tools version 6.60 or higher, allowing the UDACT-2 programming to be uploaded/down- loaded and saved. Maximum of 14 point trouble messages transmitted per hour. Dual phone lines with line voltage detect. Compact in size: 6.75" x 4.25" (17.145 x 10.795 cm). USB port for upload/download programming. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1 B/R). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. - Independent zone trouble. - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Off-Normal. —12 0r24 hour test signal. - Abnormal Test Signal per new UL requirements. - EIA-485 Communication Bus Failure. Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- soft, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. DN-60686:A1 NOTIFIER® by Honeywell > UDACT-2 Open Collector relay driver for Total Communications Failure or UDACT-2 trouble. Real-time clock. Extensive transient protection. EIA-485 interface to host panel. Programming The UDACT-2 programming is created and downloaded using VeriFire Tools. This enables the unit to be programmed prior to installation, be easily modified, and saved either online or offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- work annunciator. The point report consists of the central station point address, ACS point, ACS point function, panel label, panel point, type code, custom and extended label, alarm verification, walktest participation, presignal, and PAS information. The zone report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label and panel label. This report may be sent to the Central Station for their records. VeriFire Tools also supports upgrading the UDACT-2 operating firmware. DN-60686:A1 • 4/2/12 - Page 1 of 2 Communication Formats Ademco Contact ID 1101 • 4+2 Standard SIA NOTE: Ademco Contact ID must be used for independent zone reporting. Type Mode Feature Ademco Contact ID format - only Use Type Mode to identify reports to Central Station as: Fire Alarm Burglary Supervisory 24 hour Non-Burglary Pull Station High Temperature Heat Detector Low Temperature Waterflow Low Water Pressure Duct Detector Low Water Level Flame Sensor Pump Failure Smoke Zone Electrical Specifications Standby current: 40 mA. Current while communicating: 75 MA. I Maximum current while communicating and with open collector Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory . for latest listing status. UUULC Listed: S635 FM Approved CSFM: 7165-0028:0243 (NFS2-640/320), 7165-0028:0224 (NFS2-3030) FDNY: COA#6085, COA#6098 Ordering Information UDACT-2: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions, and mounting hardware. MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). ABS-8RB: Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP. 9.94° H x 4.63 W x 2.50° D (cm: 25.248 H x 11.760W x 6.350 D). UBS-1 B: Metal enclosure with solid door, Black. UBS-1 BR: Metal enclosure with solid door, Red. R-1 OE: SPDT Form-C relay. Contacts rated for 10 A © 115 VAC. Connects to open collector relay driver. R-20E: DPDT Two Form-C relays. Contacts rated for 10A © 115 VAC. Connects to open collector relay driver. FBD-1: Ferrite bead kit. Use for remote mounting only. UL Listed Receivers The chart below shows UL listed receivers compatible with the UDACT-2. A check in the protocol column indicates the receiver supports that protocol. Receiver 4+2 Standard 1800/2300 Ademco Contact ID SIA Ademco 685 (1) Ademco MX8000 (2) V V Silent Knight 9500 (3) Silent Knight 9800 (4) V FBI CP220FB (5) V V V Osborne Hoffman 2000E (6) V Radionics 6600 (7) V SurGard MLR2 (8) V SurGard System Ill (9) V SurGard MLR-2000 (10) V With 685-8 Line Card with Rev 4.4d software With 124060V206B and 124063 Line Card Rev B With version V2.4 Receiver & 126047 Line Card Rev G With 124077V2.00 Receiver &126047 Line Card Rev M With software V3.9 With V.7301 Receiver SIW With 01.01.03 Receiver S/W & Line Card 01.01.03 With software V1.86 With sotware V1.72 With DSP4016 and V1.6 Line Card NOTI.FIRE.NET°" is a trademark and Notifiet® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All tights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so ooi We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINNS a MMMMS All specifications are subject to change without notice. W QUALITY SYSTEMS MadeintheU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60666:A1 • 4/2/12 DVC Shown using CA-2 mounting option, SBB-C4, and ADDR-C4 door. DN-7045:G • C-7 DVC Series Digital Voice Command = DVC-EM i'i Honeywell FCantSVie General The DVC is the heart of an integrated, full-featured Audio Command Center. The DVC Digital Voice Command combines the capabilities of a powerful digital audio processor, an event- driven audio message generator, and a router. Designed for use with Digital Audio Loop (DAL) devices such as DAA2, DAX and DAA series digital amplifiers as well as the DS-DB, each DVC supports a dedicated audio network with up to eight channels of audio, five channels of firefighter telephone com- munications, and control and supervision for up to 32 DAL devices. The DVC has two wire digital audio ports to connect to wire DAL segments. Either or both ports may be converted to multi-mode fiber or single-mode fiber using fiber option modules. Larger audio systems incorporating hundreds of amplifiers can be created by networking additional DVC units via NOTI•FIRE•NET'. The DVC may be networked with ONYX® Series panels via NOTI•FIRE•NET with an NCA-2, or with an NFS2-3030 (running in network monitor mode). A DVC can be connected directly with a single NFS2-640 or NFS2-3030 Fire Alarm Con- trol Panel (FACP) to create a standalone integrated audio solu- tion as well. Refer to the DVC manual for details. When used as an Audio Command Center with Emergency Paging capability, the optional DVC-KD Keypad Display is required. NOTE: Unless otherwise noted, the term "DVC" refers to the DVC- • Auxiliary input for 12 Vp-p analog low-leve; audio sources. EM. Includes user audio level adjustment feature. S Features Programmable from NUP port using VeriFire® Tools. Up to 32 minutes of standard quality or 4 minutes of high quality digital audio storage of user-selected/created mes- sages and tones. Supports twisted-pair wire media. Sup- ports single- and multi-mode fiber-optic media when used with fiber option modules. 4-channel analog audio supported with optional DVC-AO Up to 1000 audio sequences. Message prioritization. Equations support flexible programming for distribution of messages. Electrically isolated digital audio ports for direct connection with up to 32 Digital Audio Loop (DAL) devices. Style 4 or 7 configurations supported. Optional DS-RFM, DS-FM, and DS-SFM fiber modules may be used to convert one or both Digital Audio Ports for oper- ation with single-mode or multi-mode fiber. DCC (Display and Control Center) capabilities when used with optional DVC-KD. Firefighters' Telephone Communications to local FFT riser on DVC, 32 local DAL device FFT risers, and FFT communication to additional command stations via NOTI • FIRE • NET. Local paging microphone option. Remote microphone options. Broad All-Call functionality when used with DVC-KD (DVC- Keyboard Display): All Call, Page Active Evac Areas, Page Active Alert Areas, Page Inactive Areas. Auxiliary inpLt accepts external audio sources such as tele- phone paging or background music. High impedance input accepts 600 ohm, line level, 1.0 VRMS, or 1.41 Vp-p low level audio. Selectable AGC, user control of audio level, and audio supervision are supported. Associated :"ICA-2, or NFS2-3C30 (p-ogrammed for net- work monitor mode) supports NOTI•F1RE•NET applica- tions. Multiple audio command centers supported via NOTI •FIRE•NET. Distribution of one channel of standard-level paging audio on NOTI• FIRE •NET. Three standalone, non-network node options: - NFS2-3030 (NUP to NUP) digi:al and analog. - NFS2-640 (NUP to NUP) analog audio only. - NFS2-640 with NCA-2 (NUP b NUP to NUP) digital and analog. Push-to-talk relay, or logic argurrent. Isolated alarm bus input, to be used for 3ackup activation of alarm messages in the event ietwork communication is lost. Installation Options The DVC provides flexible configurations lased on one-row or two-row chassis options that mount into size "B", "C", or "D" CAB-4 Series cabinets. The CA-2 supports a DVC, paging microphone, optional FFT telephone, and mounting locatior for an NCA-2 or NFS2- 3030D CPU. Tie ADDR audio docr series can be used when a CA-2 is mounted in the top two -ows. The CA-1 supports a DN-7045:G • C /16/2012 - Page 1 of 4 DVC and an optional microphone in a single row. For firefight- ers' telephone applications with a CA-1, the CFFT-i can be mounted in the row below the CA-1. NOTE: For NFS2-640/DVC applications using DAL devices, an NCA-2 is required to annunciate DAL device events. Refer to the DVC System Audio Product Application Guide (part number M-AG-DVC) for more details on DVC applica- tions). Specifications 24 VDC power (TB1): 24 VDC, 1.0 A, non-resettable, power-limited by the source. Recommended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted-pair. Digital audio ports, wire media, A and B (TB2, TB3): Maximum distance per segment is 1900 feet (579.12 m) on Belden 5320UJ (18 AWG, TP) FPL cable: 18 AWG (0.821 mm2) twisted-pair, foil-shielded, power-limited. Consult wir- ing documentation provided in document P/N 52916ADD:C Addendum to DVC and DM Manuals. Digital audio ports, single- and multi-mode fiber-optic media: DS-FM and DS-SFM fiber option module (no direct DAA connection): Maximum attenuation is 6.5dB for multimode with 50/125 micrometer cable @ 1310 nm; 10dB for multi-mode with 62.5/125 micrometer cable @ 1310 nm; 30dB for single-mode with 9/125 micrometer cable © 1310 nm. DS-SFM: attenuation for single-mode fiber DAA con- nection* Maximum attenuation: - 17dB for single-mode with 9/125 micrometer cable at 1310 nm going from the DS-SFM to the fiber DAA. —4dB for single-mode with 9/125 micrometer cable going from the fiber DAA to the DS-SFM. Minimum attenua- tion: 12dB going from the DS-SFM to the fiber DAA. Minimum attenuation: —2 dB going from the DS-SFM to the fiber DAA. DS-RFM: attenuation for multi-mode fiber DAA con- nection* Attenuation going from the fiber DAA to the DS-RFM: —2dB maximum for multi-mode with 50/125 micrometer cable © 850 nm for the DS-RFM. —4dB maximum for multi-mode with 62/5/125 micrometer cable © 850 nm for the DS-RFM. Attenuation going from the fiber DS-RFM to the fiber DAA: limited. Maximum distance between remote microphone and DVC: 1000 feet (300 m). Push-to-talk interface (TB10): Dry contact. Recom- mended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted- pair. Alarm bus (TB12): Power-limited by source. Recom- mended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted- pair. FFT riser (TB13): Power-limited output. Class A (Style Z) or Class B (Style Y) operation. Style Y two-wire connections require a 3.9K ohm, 1/2 watt resistor (P/N K-3.9K). Maxi- mum wiring resistance (including individual telephone zone to last handset) permitted is 50 ohms, 10,000 feet (3048 m) maximum wiring distance at 12 AWG (3.31 mm2) to last handset. Optional DVC-AO analog audio output circuits (TB5, TB6, TB7, and TB8): Supervised, power-limited outputs. Signal strength: +12 Vp.p nominal, +15 Vp-p maximum. Rec- ommended wiring: 18 AWG (0.821 mm2) twisted-pair; max. 14 AWG (2.08 mm2). Maximum impedance: 66 ohms. Standards and Codes The Digital Voice Command DVC and DVC-EM comply with the following standards: NFPA 72 2002 National Fire Alarm Code. Underwriters Laboratories Standard UL 864, 9th edition. Underwriters Laboratories of Canada (ULC) ULC-S527-99 Standard of Control Units for Fire Alarm Systems. Listings and Approvals The listings and approvals below apply to the DVC and DVC- EM Digital Voice Command. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635. ULC Listed: S635. FM Approved. CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). FDNV: COA#6065 (NFS2-3030): COA#6085 (NFS2-640). City of Chicago approved: High Rise, Class 1, Class 2 (NFS2-3030, NFS2-640, NCA-2). City of Denver approved (NFS2-3030). PSB Corporation approved (Singapore) (NFS2-3030). - 12dB minimum, 16dB for both cable types. `*11.1 Product Line Information (If the length of the fiber run results in an attenuation of less DVC-EM: Digital Voice Command, digital audio processor with than 12dB, a suitable attenuator must be used.) message storage for up to 32 minutes of standard quality (4 * ST® Style connection required at DAA end. minutes at high quality) digital audio. Supports twisted-pair wire media. Options: DS Fiber modules. Auxiliary input A (AUX A, TB4): Signal strength from lo DVC-KD: Keypad for local annunciation and controls; status level analog audio input: maximum 1.0 VRMS, or 1.41 Vp.p. LEDs and 24 user-programmable buttons. Optional supervision is selectable through programming. Recommended wiring: 18 AWG (0.821 mm2) twisted-pair; DVC-AO: Optional DVC Analog Output board provides four max. 14 AWG (2.08 mm2). Auxiliary input must be in the analog output circuits for use with AA or XPlQ Series amplifi- same room as the DVC. ers. Four-channel operation supported. Auxiliary input B (AUX B, TB14): Signal strength from low-level analog audio input: 12 Vp-p nominal, 15 Vp-p maxi- mum. Optional supervision is selected through program- ming. Recommended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted-pair. Remote microphone interface (TB9): Recommended wir- ing: 14 to 18 AWG (2.08 to 0.821 mm2) twisted-pair. Power- CA-1: Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC and a DVC-KD (optional); and the right side houses a CMIC-i microphone and its well (optional). CMIC-1: Optional microphone and microphone well assembly used with the CA-1 chassis. Page 2 of 4— ON-7045:G • 01/16/2012 CFFT-1: The CFFT-i Chassis for Firefighters' Telephone DS-DB: Digital Series Distribution Board, provides bulk ampli- mounts in the row directly under a DVC that is mounted in a fication capabilities to the DVC while retaining digital audio dis- CA-i single row chassis. The CFFT-i includes one FFT hand- tribuition capabilities. Can be configured with up to four DS- set. The DP-CFFT Dress Plate (separately ordered, require) AMPs, supplying high-level risers spread throughout an instal- has one open position for mounting an ACS annunciator or '.lation. See DN-60565. BMP-i Blank Module Plate. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC mounted on a half-chassis and one NFS2-3030 or NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes a microphone. DPA-213 dress plate is required (below); the VP-2B Vent Plate is also required for top row configurations. ADDR Series doors with two-tier visibility are available for use with the CA-2 configura- tion: ADDR-134, ADDR-C4, ADDR-D4 (below). DPA-2B: Dress plate required for CA-2 chassis assembly. VP-213: Vent plate required for cabinet configurations where the DPA-213 is used for the top two row position. TELH-1: Firefighters' Telephone Handset for use with the DVC when mounted in the CA-2 chassis. Order separately. ADDR-B4: Two-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "OR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-134. See DN-6857. S ADDR-C4: Three-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-6857. ADDR-104: Four-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-6857. DPA-1: Dress panel, can be used with the CA-1 chassis when configured with a DVC, DVC-KD, and CMIC-1. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-1 is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. ACT-4: Audio-coupling transformer. Used to electronically iso- late DVC-AO analog risers. ACT-25, ACT-70: Audio-coupling transformers for 25V and 70V high-level audio. Used to isolate and convert high-level audio to low-level, supporting applications with large numbers of analog amplifiers. DAX-3525(E)IDAX-3570(E): 35W, 25 or 70.7VRMS. Digital audio amplifiers with charging power supply and 2 Class B or 1 Class A output, shipped mounted on chassis. Options: BDA- 25/70 backup amplifier, DS Fiber modules. DAX-5025(E)/DAX-5070(E): 50W, 25 or 70.7VRMS. Digital audio amplifiers with power supply and 2 Class B or 1 Class A output, shipped mounted on chassis. Options: BDA-25/70 backup amplifier, DS Fiber modules. DAA2-5025(E)/DAA2-5070(E): 50W, 25 or 70.7VRMS. Digital audio amplifiers with charging power supply and 4 Class B or 2 Class A outputs, shipped mounted on chassis. RM-1 port, FFT port, Aux audio port. Supports optional BDA for backup ampli- fier or 2-channel operation, and DS Fiber modules. DAA2-7525(E): 75W, 25VRMS. Digital audio amplifiers with power supply and 4 Class B or 2 Class A outputs, shipped mounted on chassis. RM-i port, FFT port, Aux audio port. Supports optional BDA for backup amplifier or 2-channel oper- ation, and DS Fiber modules. requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-BDA: Digital Series Backup Digital Amplifier, 25 or 70VRMS, can be configured to act as a one-to-one backup for DS-AMP/E amplifiers. Can also be programmed to provide a second audio channel for a OS-AMP. See DN-60663. BDA-25, BDA-70: Backup Digital Amplifier, 25 or 70.7VRMS, can be configured to act as a one-to-one backup for DAX and DAA2 series amplifiers. For DAA2 Series only, supports alter- native second channel operation. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC, DS-DB distribution board, and DAX and DAA2 Series amplifiers. See DN-60633. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running SR4.0. For DAA-50 series amplifiers, see DN-7046. For DAA-7525 Series, see DN-60257. - DAA-5025: 50W, 25Vrms Digital Audio Amplifier assem- bly with DAA-PS power supply board, shipped mounted to its chassis. Supports twisted-pair wire media. (For multi- mode fiber-optic media order DAA-5025F For single- mode fiber-optic media order DAA-50255F) - DAA-5070: 50W, 70.7Vrms Digital Audio Amplifier assembly with DAA-PS power supply board, shipped mounted to its chassis. Supports twisted-pair wire media. (For multi-mode fiber-optic media order DAA-5070F For single-mode fiber-optic media order DAA-5070SF) - DAA-7525: 75W, 25Vrms Digital Audio Amplifier assem- bly with DAA-PS power supply board. Shipped mounted to its chassis (no battery charger on DAA-7525 power supply board). Supports twisted-pair wire media. (For multi-mode fiber-optic media order DAA-7525F For sin- gle-mode fiber-optic media order DAA-75255F) SEISKIT-CAB: Seismic kit for CAB-4 series cabinets. Includes battery bracket for two 26AH Power Sonic batteries and TELH- 1 telephone handset strap. See document 53829. SEISKIT-DAA: Seismic kit for DAA, DAA2 and DAX series amplifiers, required when using CHS-BH1 chassis. Includes battery bracket for two 12AH Power Sonic batteries. See docu- ment 53851. DN-7045:G • 01/16/2012 -Page 3 of 4 DN-60565:A %DS.DB Digital Series Distribution Board NOTIFIER® by Honeywell General The DS-DB Digital Series Distribution Board and its associ- ated amplifiers provide bulk amplification capability to the Digi- tal Voice Command (DVC) system while retaining digital audio distribution capabilities. Up to four DS-AMP/E amplifiers can supply high-level risers spread throughout an installation. The DS-DB converts digital audio to analog and routes it to audio amplifiers and optional backups. The amplifiers send back high-level audio, which the DS-DB routes to its risers. Control and status information passes between the DS-D13 and its components via ElA-485 bus. The DS-DB communi- cates with the rest of the digital audio system through the DAL (digital audio loop), and takes up two of the 32 DAL addresses. It may be mixed with other devices on the same DAL, such as the DAA2 and DAX series amplifiers. An optional Firefighters' telephone riser on the DS-DB sup- ports local and network FFT communications. Features Input capacity of four digital audio channels. Four DVC-AO-level audio outputs for connection to amplifi- ers in the same cabinet. Eight high-level audio inputs (four primary, four backup), each input capable of handling 125W of audio at 25VRMS or 100W at TO.7VRMS. Four Class A/eight Class B high-level 125W audio outputs, each of which can output all 125 watts from any one of the four high level primary inputs or four high-level backup inputs. Two digital audio loop wire ports, which may be modified to single- or multi-mode fiber ports with fiber option modules. USB port for VeriFire Tools® communication. Local FFT riser, capable of acting as a connection on the digital FFT riser. DS BUS interface to communicate with local bulk amplifiers and power supplies. Up to 106 seconds of standard quality backup digital mes- sage storage (from VeriFire Tools® message library, or cre- ated by the installer) for use in the event of communication loss with the DVC. Isolated alarm bus input, to be used for backup activation of alarm messages when normal communication with the DVC is lost. Audio output activation via network control-by-event equa- tions resident within the DVC. Uploads and downloads via the DVC. 24 VDC input for local power. Works with AMPS-24 power supply and battery charger. Installation The DS-DB arrives from the factory already installed on its chassis. The DS-DB mounts in a CAB-4 Series cabinet, as well as in an EQCAB Series backbox. One or two fiber option modules will plug directly onto a DS- D13 for simple installation. A DS-BDA backup amplifier mounts directly onto a DS-DB. Specifications 24 VDC Input (TB24): 0.6A alarm or standby, non-resettable. Power-limited by source, supervised. Any device connected to TB24 must be installed in the same enclosure, or within the same room in conduit. Digital Audio Ports, wire media, A and B: EIA-485 protocol, power-limited. Maximum distance per segment is 1900 feet (579.12m) on Belden 5320UJ (18AWG, TP) FPL cable: 18AWG (0.821 mm2) twisted-pair, unshielded, power-limited. For approved cable types, see wiring documentation, PN 52916ADD, Approved Wire Cables for Digital Audio Loops. Digital Audio Ports, fiber media, fiber option modules: Dig- ital audio loop connectors support single- and multi-mode fiber with the use of fiber option modules. Refer to the fiber option datasheet for fiber specifications. Alarm Bus: Power-limited, supervised by source. Recom- mended wiring: 14-18 AWG twisted-pair. Requires 16VDC minimum @ 20mA across the terminals to activate. Nominal 24VDC. FF1 Riser: Power-limited output, supervised. Class A or Class B operation. Class B 2-wire connections require a 3/9k ohm 1/ 2 watt resistor (PN R-3.91K). Max. wiring resistance (including individual telephone zone to last handset) permitted is 50 ohms, 10,000 ft (3048 m) max. wiring distance at 14 AWG to last handset. DS-BUS: ElA-485 protocol, power-limited. DS-BUS points must be installed in the same enclosure or within the same room in conduit. End points require end-of-line resistors. DS-DB endpoint: set termination switch (SW8)to ON. DS-AMP endpoint: add 120 ohm resistor on empty T131 ter- minals. AMPS-24 endpoint: resistor is present, and power supply must be an endpoint. Use 14-18 AWG, twisted unshielded wire. Audio Out: Power-limited outputs (exception: an output pro- grammed for "Riser Mode to Control Modules", "Riser Mode to RSM-AIM Series Modules", or "Riser Mode to ClM/CSM Series Modules" is non-power-limited.)Up to 125 Watts output. DN-60565:A.01/16/2012—Page 1 of 2 Supervision determined by programming. 25VRMS or 70VRMS, depending on amplifier setting. Class A or Class B operation. Class B requires 20k end-of-line resistors (included, PN ELR- 20K). Class A required 10k end-of-line resistors (included, PN R-10K) on the return. 12-18 AWG twisted-pair (shielded rec- ommended). Primary and Backup 1 thru 4: Four DVC-AO-level audio out- puts for connection to amplifiers. Non-power-limited inputs. Supervision programmable. Amplifiers must be installed in the same enclousre or within the same room in conduit. Recom- mended wiring: 14-18 AWG, twisted-pair, unshielded. OUT: Four DVC-AO-level audio outputs for connection to amplifiers. Power-limited. Supervision programmable. Amplifi- ers must be installed in the same enclosure or within the same room in conduit. 14-18 AWG, twisted-pair, unshielded. DS-FM: Fiber option module for multi-mode fiber. Converts a wire DAP (digital audio port) to a multi-mode fiber port. See DN-60633. DS-SFM: Fiber option module for single-mode fiber. Converts a wire DAP (digital audio port) to a single-mode fiber port. See DN-60633. DS-RFM: Fiber option module for multi-mode fiber. Used exclusively for compatibility with multi-mode fiber DVC or DAA. See DN-60633. Standards and Codes The DS-DB Digital Series Distribution Board complies with the following standards: NFPA 72 2007 National Fire Alarm Code Underwriter Laboratories Standard UL 864 Underwriter Laboratories of Canada (ULC) ULC-S527-99 Standard of Control Units for Fire Alarm Systems Part 15 Class A conducted and radiated emissions as required by the FCC. Listings and Approvals These listings and approvals apply to the DS-DB Digital Distri- bution Board. In some cases, certain modules may not be listed by certain agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 ULC Listed: S635 CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). FDNY: COA#6065 (NFS2-3030): COA#6085 (NFS2-640). Product Line Information DS-DB: Digital Series Distribution Board. DS-AMP: 120 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMS), 100W (70VRMS). Ships with chassis. See ON- 60663. OS-AMPE: 220-240 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VRMs), 100W (70VRMS). 70VRMS configuration requires step-up transformer. Ships with chassis. See ON- 60663. DS-BDA: Backup amplifier, provides an economical means of backup for DS-AMP amplifiers in a one-to-one primary/backup configuration. Can also provide a second audio channel for a DS-AMP when programmed as a primary ampifier. 25VRMS or 70VRMS . 70VRMS configuration requires step-up transformer. See ON-60663. DS-XF70V: Step-up transformer, required for 70VRMS config- uration of DS-AMP/E and DS-BDA. Ordered separately. See DN-60663. NOTIFIER® and yen-Fire® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. S This document is not intended to be used for installation purposes. Iso ooi We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. b_dU_U_ lf&lNI & MUWRINI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notitier.com Page 2012— DN-60565:A • 01/16/2012 As part of a DS-DB Digital Series system, the DS-AMP Digital Series amplifier provides bulk amplification to a Digital Voice Command (DVC) system. Up to four DS-AMP amplifiers can be connected to one DS-DB to supply high-level audio. Backup audio circuits are available by adding DS-BDA or dedi- cated DS-AMPs. Features 125 watts of audio power at 25VRMS. 100 watts of audio power at 70VRMS. This option requires step-up transformer DS-XF70V, ordered separately. Compatible with a DS-BDA that is being used as a backup or second audio channel. (A DS-BDA used as a backup or second channel for a DS-AMP configured for 70VRMS requires step-up transformer DS-XF70V, ordered sepa- rately.) EIA-485 communication with DS-DB. Installation The DS-AMP arrives from the factory already installed on its chassis. It mounts in one row of any EQ or CAB-4 Series cabi- net. The CAB-4 row can be covered using a DP-1 B dress panel, ordered separately. A step-up transformer (ordered sep- arately) easily mounts on the front of the DS-AMP for 70VRMS configurations. Specifications AC Power, TB4: 120 VAC 50/60Hz input; 4.1 A maximum when used for 25V (125W). 3.55 A maximum when used for 70V (100W). E version: 220-240 VAC 50/60 Hz input; Standards and Codes The DS-AMP amplifiers comply with the following standards: NFPA 72 2007 National Fire Alarm Code. Underwriter Laboratories Standard UL 864. Underwriter Laboratories of Canada (ULC) ULC-S527-99 Standard of Control Units for Fire Alarm Systems. Part 15 Class A conducted and radiated emissions as required by the FCC. Listings and Approvals These listings and approvals apply to the DS-AMP amplfiers. In some cases, certain modules may not be listed by certain agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: 5635. ULC Listed: S635. CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). FDNY: COA#6065 (NFS2-3030): COA#6085 (NFS2-640). 2.4 A maximum when used for 25V (125W). Product Line Information 2.1 A maximum when used for 70V (100W). Recommended wiring: 12-14 AWG (1.6 mm O.D.) with 600 DS-AMP AMPLIFIERS VAC insulation. \.Shipped mounted to the chassis. Battery Connections: Supplied cable connections to batter- DS-AMP: 120 VAC Digital Audio Amplifier (50/60 Hz), 125W les. (25VRMS), 100W (70VRMS). For battery sharing, use 12 AWG either in the same cabinet or in conduit for no more than 20 feet (6.09 meters). High Level output (TB3): Non-power-limited, supervision pro- vided by DS-DB. Recommended wiring: 14-18 AWG, twisted- pair, unshielded. Audio In (TB2): Power-limited, supervision provided by DS- DB. Recommended wiring: 14-18 AWG, twisted-pair, unshielded. DS-AMPE: 220-240 VAC Digital Audio Amplifier (50/60 Hz), 125W (25VQRAQ. 100W (70VQAQ). 70VAQ confiouration requires step-up transiormer. DS-BDA AMPLIFIER Backup amplifier, provides an economical means of backup up DS-AMP amplifiers in a one-to-one primary/backup configura- tion. Can also provide a second audio channel for a DS-AMP when programmed as a primary amplfier. DS-BDA: 25VRMS or 70VRMS. 70VRMS configuration requires step-up transformer. STEP-UP TRANSFORMER DS-XF70V: Transformer required for 70VRMS configuration of DS-AMP/E and DS-BDA. Ordered separately. DN-60663:A.O1/16/2012—Page 1 of 2 Appendix A: DS-DB and D'AMP Battery Calculations Description Column A Amps in Standby Column B Amps in Alarm QTY X current draw = Total QTY X current draw = Total DSDB* 1 X [ 0.355A ] = 0.355A 1 X [ 0.550A ] = 0.550A DS-FM (all models) [ X[ 0.060A I = I ] X L 0.060A j = 24V Auxiliary Power (T1324 on DS-DB) [ ] X[ I = [ ] X [ J = DS-AMP (25V) [ ] XE 0.125A ] = [ ] XL 0.280A ] = DS-BDA (25V) [ ] X [ 0.100A ) = I I XL 0.300A ] = DS-AMP (70V) [1 XL 0.130A ] = I] XE 0.300A ] DS-BDA(70V) LI XI 0.105A 1= [1 XL 0.330A 1= AMPS24*** [.1 XL 0.130A J = I ] XE 0.130A ] = Speakers: 1/4 waft 1/2 waft 3/4 watt 1 watt 2watt Other I I X[ 0.016A ]= LI XL 0.031A ] [ ] XL 0.047A ] = I I X [ 0.062A ] = I I I XE 0.124A 1= [ ] XL I = [ X I ] = Total Column A Total Column B * Includes FFT Riser Draw ** Refer to the documentation that comes with the device(s) being powered through the DS-DB's TB24 for standby and alarm figures. ***If the AMPS-24 is powering additional components, refer to the AMPS-24 manual for standby and alarm figures. Table A.1 Current Draw Calculations for DS-DB and DS-AMP DS-DB - PIN 53622:B2 9/11/2014 53 • MEA: 327-94-E Vol.111 CSFM: 7165-0028:0243 (NFS2-640) FM: Approved (RM-1, RM-1SA) FDNY: #6058 (NFS2-3030) DN-6728:B RM-1 Series Remote Microphone and Cabinets \ZI RM-1, RM-ISA, CABRM, CAB-RMR by Honeywell GENERAL The RM-1 Series Remote Microphone provides a cost- effective microphone interface for paging to selected speaker zones. The Power and Trouble LEDs provide easy-to-under- stand visual indications of its status. Various mounting options are available. The microphone assembly can be mounted in a small, compact enclosure or located in a com- prehensive paging command center. The RM-1 Series remote microphone can be utilized with the DVC Digital Voice Command Center and DAA2 amplifiers, or to expand a legacy installation. FEATURES Automatic gain control circuit. Supervised microphone. Form-C trouble contacts. Form-C contacts activated when microphone is in use. Power On LED. Trouble LED. Pluggable terminal blocks. Low-level audio (LLA) IN and THRU screws. . CAB-3/CAB-4 SERIES INSTALLATION The RM-1 can mount to the back of an ADP-4B dress panel inside a CAB-3 or CAB-4 Series cabinet. It can be mounted in any of the four positions on the dress panel, with the fol- lowing exception: Do NOT mount the RM-1 in front of a CHS-4L chassis. See page 2 for illustrations of mounted units. SPECIFICATIONS Power requirements: 20 mA primary, non-fire alarm cur- rent; 66 mA when microphone is activated; 20 mA secondary, non-fire alarm current. Operating voltage: 17 to 26.4 volts. PRODUCT LINE INFORMATION RM-1: Remote microphone assembly for mounting on an \.NADP4B dress panel. RM-1SA: Remote microphone assembly for mounting in a NCAB-RM(R), for remote applications. CAB-RM: Stand-alone cabinet, black. CAB-RMR: Stand-alone cabinet, red. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the RM-1 Series Remote Microphone. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. . • UL: S635 ULC: CS118/CS733 Vol. 12 DN-6728:6 • 7/28/2010 - Page 1 of 2 is Ih81tI CAB-RM/CAB-RMR DIMENSIONS inches (mm) 1.00" (25.4) IF To 3.655" (92.8) 4.29" 6.301 (160) (109)' I 8.301 (210.8) DEPTH WITHOUT DOOR E --------------- LP RM-1 MOUNTING & CABINET DIMENSIONS \ Ill AT RIGHT: RM-ISA (right) and'\ Ii in CAB-RM or CAB-RMR BELOW RM-1 (left) and on 6728rrn1 w,w 1.04 - 6.08'(154.4)- (26.4) - 4.00 (101.6)—$1 HEIGHT/WIDTH WITHOUT DOOR NOTIFIER® is registered trademark of Honeywell International Inc. tit201 0 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. - INSIF(IN & MAMMM119 All specifications are subject to change without notice. ' QUALITY SYSTEMS MadeintheU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - DN-6728:13 • 7/28/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17165-0028:0243 I Page 1 of 4 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: ModelNFS2-640,lNFS-320/C (R), and NFS-320SYS fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), manual, automatic, waterfowl and sprinkler supervisory services. Also suitable for releasing service, Process Management and Emergency Voice/Alarm communication System * Model numbers may be followed by an "R" suffix representing the enclosure color being red. Refer to listees data sheet for additional detailed product description and operational considerations. System components: ACM-8R, -I6AT, -32A, -24AT, -48A; Annunciator Control Modules ACPS-61 0, AMPS-24; Addressable power supply/charger ADP-413, -A4, -1, -2, DP-D15P2; Dress Panel AEM-16AT, -32A, -24AT, -48A; Annunciator Expander Modules AFM-16A, -I6AT, -32A; Annunciator Fixed Modules AKS-1B; Annunciator Key Switch APS2-6R; Power supply BB-100, -200, NFS-LBB/-LBBR; Battery Boxes BGRA-SCS, BGRB-SCS; Smoke Control Station BMP-1; Blank Module BP-4, BP24; Battery Dress Plates CAB-3/4 Series; Enclosure CAB-RP, CAB-RPR; Cabinets CEF-SCS; Smoke Control Station CHS-4, CHS-4N, CHS-4L; Chassis CPU2-640, CPU-320SYS; CPU Board CRT-2; Display Terminal DP-1B; Blank Panel DPA-1A4/1/2, DP-DlSP2; Dress Panel DPI-232; Panel Interface DR-A4, DR-A413, DR-A4BR, DR-A4R; Door Assembly DR-AA4, DR-AA413, DR-AA4BR, DR-AA4R; Door Assembly DR-133F; Door Assembly DR-134, DR-13413, DR-13413R, DR-134R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly *Rev. 10-29-13 gt This listing is based upon technical data the test results and/or other data but does an endorsement or recommendation of operational requirements or installation criteria. submitted by the applicant. CSFM Fire Engineering staff has reviewed not make an independent verification of any claims. This listing is not the item listed. This listing should not be used to verify correct Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 2 of 4 EQ Series; Cabinets EQBB-B4, EQBB-C4, EQBB-D4; Backbox Assembly EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1, FCM-1-REL; Releasing Control Module FCPS-24S6, -24S8; Field Charger/Power Supply FDM-1; Dual Monitor Module FDRM-1:Multiple Module with two Relay Outputs FDU-80/-80G; Remote Annunciator FIRSTVISION-LCD/ENC; Interactive Firefighters' display/enclosure FRM-1; Relay Module FTM-1; Control Module FZM-1, FMM-1, FMM-101; Monitor Modules HS-NCM-W/-MF/-SF/-WMF/-WSF/-MSSF; High Speed Network Control Modules IPDACT-2/-2UD; IP Fire Alarm Communicator ISO-X; Isolator Module KAPS-24, CPS-24; Power Supply KDM-R2; Keyboard Display Module LCD-80, -160; Annunciators LCD-80TM; Annunciator Terminal Module LCD LCD2-80; Remote Annunciator LDM-32/-E32/-R32; Lamp Driver Module LEM-320/ELEM-320; Loop Expander Module NBG-I2LRA; Agent Releasing Abort Station NBG-I2LX; Addressable Manual Pull Station NCA, NCA-2; Network Communication Annunciator NCM-W, -F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station NFS-LBB/NFS-LBBR; Battery Box/Red NFS-320SYS; Chassis NFV-25/50, NFV-25/50ZS/ZST; Voice Evacuation Control Panels NFV-25/50DA, NFV-25/50DAZS; Distributed Audio Panels ONYXWorks-EW/-NW-/NF/-HNW/-HNMF/-HNSF/-TS/-EW-TS/-NF-TS/-HW-TS/ -HNMFTI-HNSFT/-HNWT; PC workstation for NOTI .FIRE.NET, Wire/Fiber/ with Touch screen monitors PRN-6; Printer RKS-S; Remote Security Key Switch RPT-W, -485W; Repeater Wire RPT-F; Repeater Fiber RPT -485FW; Repeater Fiber/Wire RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-AA4R; Backbox Assembly SBB-134, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed. the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 3 of 4 . SCE-8; Smoke Control Expander SCS-8L; Smoke Control Lamp Driver Station SCE-8L; Smoke Control Expander Lamp SCS-8; Smoke Control Station STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A4/-B3N/-B4/-C4/-D3NI-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-256; Universal Zone Coder VP-2B; Dress Panel XP5-C/-M; Transponder Modules XP6-C; Supervised Control Modules XP6-MA; Six Zone Interface Modules XP6-R; Six Relay Control Modules XPIO-M(A); Ten Input Monitor Modules XPM-8L; Transponder Monitor Modules The following models are intended for use on NFS2-640 only: AA-30, -100, -120; Amplifiers ACT-I, -2, -4, -25, -70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4R/-D4/-D4R; Door Assemblies AMG-E; Audio Message Generator AVL-I; Audio Voice Link BDA-25V/-70V; Backup Digital Audio Amplifiers CHS2-M2, CA-1, CA-2; Chassis CMIC-1, CMlC-RP; Microphone Assembly is DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-50255F; Digital Audio Amplifiers DAA-5070F/DAA-50705F; Digital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-75255F; Digital Audio Amplifiers DAA2-5025/-5070/-7525; Digital Audio Amplifiers >DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DS-AMP/E; Digital Series Audio Amplifier > DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module >DVC; Digital Voice Command DVC-EM/-EMFI-EMSF; Digital Voice Command Extended Memory Module DVC-RPU; Remote Paging Unit FFT-7, -7S; Fire Fighter's Telephone FHS; Fireman's Handset FPJ; Fireman's Phone Jack RM-1, RM-1 SA; Remote Microphone *Rev. 10-29-13 gt ør. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0243 Page 4 of 4 . TELH-1; Telephone Assembly XPIQ; Transponder Quad Intelligent Audio INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label APPROVAL: Listed as fire alarm control units suitable for use in high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. *Control units may be used with Notifier's First Command NFC-50/100 emergency voice evacuation panals (CSFM # 6911-0028:0265). This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 Seconds. 2. Combined with 7170-028:244 S *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division -,-- 68201d08 pg Ordering Information FDU-80: 80 character, backlit, LCD Fire Annunciator with con- trol switches for remote control of system functions, and key- switch lock. FDU-80C: ULC-listed version; see DN-60573 for details. 10103: Three-gang electrical box, minimum 2.188' (5.556 cm) deep, for semi-flush mount applications. SBB-3: Three-gang surface backbox for surface-mount appli- cations. Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 MEA Listed: 245-00-E FDNY: COA#6038 CSFM: 7120-0028:209 FM Approved NOTE: For ULC-listed version, see DN-60573. DN-6820:13 • D-123 FDU-80 NOTIFIER ®R 80 Character Liquid Crystal Display by Honeywell General The FDU-80 is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the NOTIFIER Fire- Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACP5). The FDU-80 mimics the display of the control panel and displays complete system point status information. Up to 32 FDU-80s may be connected onto the ElA-485 termi- nal port of each FACP. The FDU-80 requires no programming, which saves time during system commissioning. Features 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced. No programming necessary - FDU-80 connects to the ter- minal porton the FACP. Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. Time-and-date display field. Aesthetically pleasing design. May be powered from the host FACP or by remote power supply (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from the FACP. Local piezo sounder with alarm and trouble resound. Semi-flush mounts to 2.188' (5.556 cm) minimum deep, three-gang electrical box (NOTIFIER PN 10103) or three- gangable electrical switchbox. Surface-mounts to NOTIFIER PN SBB-3 surface backbox. Operation The FDU-80 annunciator provides the FACP with point annun- ciation with full display text on an 80-character LCD display. The FDU-80 also provides an array of LEDs to indicate system status, and includes control switches for remote control of criti- cal system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an SBB-3 surface Ah backbox is available for surface-mount applications. DN-6820:B.05/17/2010—Page 1 0t2 NOTIFIER® is registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. RCT U U We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6820:13 • 05/17/2010 ire Alarm Control Panel installation Manual AF-tA x [ J LO25J= ACM-OR (refer tomaRtad")[ x[ = [ j x( = I I I 1= LEMfertmanuafl x( [ ] xI ) -L)U.&J LW-4J. LfA.11-W X F J [ I x ujw,- CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: 1 7120-0028-0-2-09-1 Page 1 of 1 7120--ANNUNCIATORS NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com Models FDU-80 nd FDU80G remote fire annunciators. Units are compact 80-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. *Rev. 10-03-06 jw To This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Add cellular communicatior to any fire pane Extend the Life and expand the capabilities of older panels by adding the power of advanced, digital cellular communication. With this simple communications add-on, almost every panel can take advantage of revenue-building remote system management and control features. O Provide central station communication over cell for any burglary commercial fire or residential fire panel Use Contact ID capture. 4 zones, or Bell Monitoring CellComSLCTM and CelLComSLCF enables basic remote panel control via Virtual Keypad AppTM Provides end user alerts of arming/ disarming, alarm, and other events Add Z-Wave control of lights, locks, and thermostats with CellComSLCZTM CELL - èJ! U1fr'i COMMUNICATOR I.1 SYSTEM FEATURES Fully supervised universal alarm communication over COMA • Wiring for Ademco ECP Bus Fully supervised universal fire alarm communication over • Communicates with DMP SCS-1 R and SCS-VR Receivers CDMA • Builds customer loyalty; creates new RMR Program your own account number to easily workaround locked • Armed/disarmed status LED panels • Private Labeling available on the rubber Logo Contact ID dialer capture • Two outputs Four zones or Bell Monitoring -,----- .— WORKS WiTh MOST PANELS If the existing panel supports Contact ID. then it's a candidate for upgrading with the CellComSLC. CelLComSLCZ. or CellComSLCF. There are no issues with lockout codes. Simply add the CellComSL unit to the existing installation and program in your own account number. BL GLARY UMMUNICATION The CellComSLC provides control of basic panel security functions and video. The CellComSLCZ adds the ability to remotely interact with Z-Wave devices, enabling a variety of home automation features including control of lights, door locks, thermostats and more. COM ATION The CellComSLCF offers cellular fire communication on any fire control panel via Contact ID Captures or Zone Inputs. Meets NFPA 72 Standard for Single Communication Technology. 1r"c1 MOBILE SYSTEM CONTROL With CellComSL communicators you can easily update your older residential and commercial customers to the latest cellular communication links. With cellular in place, end users can remotely access their panels via the Virtual Keypad AppTM. This makes it possible to use their mobile device not only to control basic arm/disarm functions and receive alerts, but also to controlZ-Wave home automation devices for lights, door locks, thermostats, and more with CetlComSLCZ. ENABLE VIDEO ON THE APP Video is no longer an expensive option. With the CelLComSLC communicators, you can easily add up to six wireless cameras. Via the Virtual Keypad App, end users can do a remote visual survey of their premises to confirm an alarm or simply check in on children or senior adults. Users can also capture still or video images. FULLY SUPERVISED COMMUNICATION Provides a fully supervised alarm communication path for burglary control panels over the CDMA network providing higher speeds. CellComSL allows alarm messages to be communicated to an ScS-1 R orSCS-VR Receiver over the COMA network. COMA operates on the Verizon network. HELD PANEL. UPDATES The Model 400 USB Flash Module allows you to easily field update firmware for panels that would otherwise require the use of a computer and a Model 399 Programming Harness. SYSTEM PROGRAMMING System programming over cell via VirtualLinkTM includes zone information and Central Station communications. MULTIPLE CONNECTION OPTIONS CellComSL communicators can be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer, or conned the four input zones from outputs on the panel; or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the Central Station. 'ZONES Each of the CellComSL models provide four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. IUPGR .FORE ONLY PANELS Older, dial-up panels have new life with the addition of cellular communication. Earn customer loyalty by extending the life of their existing panels, enabling them to increase the ROI on theirsystem investment and build satisfaction with the purchase decision. BUILD CUSTOMER LOYALTY Avoid the possibility of customers seeking mobile intrusion alarm features from a competitor by enabling those features on their existing panel with a minimal additional cost. They are less likely to switch systems and cancel theircontract. When the time does come to replace the panel, they are more likely to rely on you. The app can be branded with your organization's logo and contact information to provide a daily reminder of yourservices. OUTPUTS Use outputs to conned to an arming zone of an existing panel for control of that panel U, via the App. SPECIFICATIONS . FICATIONS Dimensions: 5.5 W x 3.75" H X 1 0 California State Fire Marshal (CSFM) Color: White Open-Collector Outputs: 2 ANSI/UL 1610 Central Station Burglar (Cellular) Zones: 4 ANSI/UL 1023 Household Burglar Primary Power (Cel1ComSLC/SLCZ): 12VDC ANSI/UL 985 Household Fire Warning (CID Capture) Primary Power (CellComSLCF): 24VDC ANSI/UL 864 Fire Protective Signaling Systems .181 mA Cellular Curren rNG y .061 mA FCC Part 15: MIVCNNO3O1 ORDERFORMATION CellComSL CellComSLC Universal Alarm Communicator FCC Part 15 ID: CCKPO159 CellComSLCF Universal Fire Alarm Communicator IC: 5251 APc0159 ...Universal Alarm Communicator, Z-Wave ......................-...-... .... — 2500 North Partnership Boulevard sringfiettMissouri 65803-8877 800.641.4282 I dmp.com Designed. Engineered & Manufactured in Springfield, Missouri CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17300-1157:0136 I Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: Modelsi CelIComSLCFj CellComSLCZ, *CellComSLCF* iComSLF, iCOMSL and iComSLZ Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. RATING: 12 VDC or 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and ETL label. APPROVAL: Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *Rev. 07-14-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications SpectrAlerl' Advance selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation. Features Plug-in design and protective cover reduce ground faults Universal mounting plate with an onboard shorting spring tests wiring continuity before installation No extension ring required Field selectable candela settings: Standard: 15, 15/75, 30, 75, 95, 110, 115 High: 135, 150, 177, 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4,1/2, 1 and 2 watts) SF speakers offer high fidelity sound output SPV speakers offer high volume sound output Compatible with System Sensor synchronization protocol Electrical compatibility with existing SpectrAlert products Optional tamper resistant Torx head screw included Listed for ceiling cr wall mounting Agency Listings SIGNALING .0LISTED approved S4048 7320-165320 10-05-E The SpectrAlert Advance Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 11 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SF speaker offers high fidelity sound output while the SPV speaker offers high volume sound output for use in high ambient noise applications. SpectrAlert Advance makes installation easy Attach a universal mounting plate to a 4 x 4 x 21,8 inch back box. Flush-mount applications do not require an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Rotate the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance Speaker and Speaker Strobe Specifications General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 21,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the SyncsCircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SyncsCircuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model ______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model _________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411/16 x 411/16 x 21,8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together wil synchronize all the zones they control. The module shall not operate on a coded power supply. *Phvsical Specifications W Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Ceiling-Mount SPS Speaker Strobe 6.8 in Dia. x 4.7 in D (including lens and speaker) SPSV Speaker Strobe 6.8 in Dia. x 4.8 in D (including lens and speaker) SP Speaker 6.8 in Dia. x 2.8 in D SPV Speaker 6.8 in Dia. x 2.9 in D Nominal Voltage (speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 V DC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) alarm panels with built In sync) Operating Voltage with MDL Sync Module 9 to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz Power 1/4,1/2, 1, 2 watts AVDSOO7O1 ME11449 =T, IUL Max. Strobe Current Draw (11 8 to 17.5 Volts 16 to 33 Volts Candela DC FWR DC FWR Standard I 15 I 123 128 I 66 I 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 Sound Output UL Reverberant (dBA @ loft.) NA 2W NA 1W 286 '/2W 258 ¼W Ceiling-Mount SPC Series 86 83 80 77 Ceiling-Mount SPCV Series 90 87 84 81 Ceiling-Mount SPSC Series 85 82 79 76 Ceilinci-Mount SPSCV Series 89 86 83 80 Dimensions Ceiling-Mount SPV Speaker Ceiling-Mount SP Speaker Ceiling-Mount SPS Speaker Strobe AVDSOO7O1 Surface Mounting Ill Ceiling-Mount Speaker with SPBBSCW Back Box Ordering Information for SpectrAlert® Advance Speakers and Speaker Strobes White Red SPCW SPCR Speaker only SPCV\N SPCRV Speaker only, High dB SPSCW° SPSCR Speaker Strobe, Standard cd SPSCWH° SPSCRH Speaker Strobe, High cd SPSCWV° SPSCRV Speaker Strobe, Standard cd, High dB SPSCWVH SPSCRVH Speaker Strobe, High cd, High dB SPSCW-CLR-ALERT - Speaker Strobe, Standard cd, Clear Lens 'Accessories White Red Description RFPW REP 7 in x 9.5 in Retrofit Plate SPBBSCW SPBBSC Ceiling Mount Back Box Skirt TRCW TRC Ceilina Mount Trim Rina Notes: * Add -P to model number for plain housing (no 'FIRE" marking on the cover) e.g. SPSCW-P "Standard cd' refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. .'5)021) 2 System Sensor. S'7EiI' 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject tolchange vothout notice, Visit systemsensercom SENSOR Phone: 800-SENSOR2 • Eax: 630-377-6495 for current product nforrrr0000 including the latest version of the data sheet, SYSTEM SENSOR Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications The SpectrA len® Advance selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation. r sys!s or Features • Plug-in design and protective cover reduce ground faults Universal mountirg plate with an onboard shorting spring tests wiring continuity before installation No extension ring required Field selectable candela settings: Standard: 15, 15/75, 30, 75, 95, 110, 115 High: 135, 150, 177, 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candea Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4,1/2, 1 and 2 watts) SF speakers offer high fidelity sound output SPV speakers offer high volume sound output Compatible with System Sensor synchronization protocol Electrical compatibility with existing SpectrAlert products Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGNALING ® X) <~, MEA LISTED approved S4048 73.1653701 10-08.E The SpectrAlert Advance Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 11 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SF speaker offers high fidelity sound output while the SPV speaker offers high volume sound output for use in high ambient noise applications. SpectrAlert Advance makes installation easy Attach a universal mounting plate to a 4 x 4 x 21,8 inch back box. Flush-mount applications do not require an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance Speaker and Speaker Strobe Specifications General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 21,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the SyncsCircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Incoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177. 185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model ______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model _________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411/16 x 411/16 x 21,8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 320F to 120oF (OoC to Humidity Range 10 to 93% non- condensing Dimensions, Wall-Mount Length Width Depth SP Speaker 6 in, 152 mm 5 in, 127 mm 2.8 in, 71 mm SPV Speaker 6 in, 152 mm 5 in, 127 mm 2.9 in, 74 mm With Surface Mount Back Box 6 in, 152 mm 5.1 in, 130 mm 3.4 in, 86 mm SIPS Speaker/Strobe 6in, 152 mm 5.1 in, 127 mm 4.7 in, 119 mm (including lens and speaker) With Surface Mount Back Box 6 in, 152 mm 5.1 in, 130 mm 5.325 in, 135 mm ons Nominal Voltage (speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC/ FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire 8 to 17.5 V (12 V alarm panels with built in sync) nominal) or 16 to 33V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33V (24 V nominal) Frequency Range 400 to 4000 Hz Power 1/4,½,1,2watts n . UL Current Draw Data Candela 8 to 17.5 Volts DC FWR 16 to 33 Volts DC FWR Standard Candela Range 115 1 123 128 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 Candela Range 150 177 185 NA NA NA NA NA NA NA NA 228 246 281 286 207 220 251 258 UL Reverberant (dBA @10 ft.) 2W 1W ½W 1/4 W Wall-Mount SP Series 86 83 80 77 Wall-Mount SPV Series 90 87 84 81 Wall-Mount SIPS Series 85 82 79 76 Wall-Mount SPSV Series 89 86 83 80 Dimensions 5 61 Wall-Mount SP Speaker Wall-Mount SPS Speaker Strobe Surface Mounting Wall-Mount Speaker Strobe with SBBSPR Surface Mount Back Ordering Information for SpectrAlert® Advance Speakers and Speaker Strobes wiT1lIilrn \ White Red Description SPW SPR Speaker only SPWV SPRV Speaker only, High dB SPSW SPSR Speaker Strobe, Standard cd SFSW-P SPSR-P Plain Speaker Strobe, Standard cd SPSW-ALERT - Speaker Strobe, Standard cd, Amber Lens SPSW-CLR-ALERT - Speaker Strobe, Standard cd, Clear Lens SPSWH SPSRH Speaker Strobe, High cd SPSWH-P - Plain Speaker Strobe, High cd SPSWV SPSRV Speaker Strobe, Standard cd, High dB SPSWV-P SPSRV-P Plain Speaker Strobe, Standard cd, High dB White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBSPW SBBSPR Surface Mount Back Box for Speakers and Speaker Strobes TRW TR Wall Mount Trim Ring Notes: All-P models have a plain housing (no "FIRE" marking on the Cover) "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. . T'\ 4W 3825 3825 Ohio Avenue • St. Charles, IL 60174 02015Systen Sensor. -aUms subject to change Without notice. Visit systernsensorcom Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information, including the latest version of this data sheet. IVLFSW www.systemsensor.com evosllsos.2/15 S S SYSTEM — ~45 SENSORS Outdoor, Selectable- Output Speaker Strobes and Dual- I4 Voltage Evacuation Speakers for Wall SPECTPAlert - - 14 U I _________ SpectrAlert Advance outdoor; selectable-output speaker strobes and dual-voltage evacuation speakers meet virtually any outdoor application requirement. Features Weatherproof per NEMA 4X, 1P56 Rated from -40°F to 151°F Plug-in design reduces ground faults Universal mounting plate with onboard shorting spring that tests wiring continuity before devices are installed Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for speaker voltage (25 and 70.7 Vrms) and power settings (1/4, 1/2, 1 and 2 watts) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings • SIGNALING C MEA LISTED R___. approved 75S0 7320-1653201 1O-08-E SpectrAlert Advance offers the broadest line of outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic housings, to wall and ceiling mounting options, SpectrAlert Advance can meet virtually any application requirement. Wall-mount outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40°F to 151°F. These speakers provide a broad frequency response range, low harmonic distortion and maintain a high sound pressure level at all tap settings to provide accurate and intelligible broadcast of evacuation messages. Like the entire SpectrAlert Advance line, wall-mount outdoor speakers and speaker strobes include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, speaker voltage and power settings, and automatic selection of 12- or 24-volt operation enable installers to easily adapt devices to meet requirements. Next, these devices use a universal mounting plate with an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verity proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 3,4-inch top and bottom conduit entries and 3A-inch knock-outs at the back. A screw-in NFl plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert® Advance Outdoor Speaker and Speaker Strobe Specifications 1 General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the SyncsCircuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40°F and 151°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems. Speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature from —40°F to 150.8°F Speaker shall have power taps and wattage settings that are selected by rotary switches. The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048. The speaker shall be suitable for use in air handling spaces and wet environments. Speaker Strobe Combination The speaker strobe shall be a System Sensor Model listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4,000 Hz. Speaker, shall have power taps that are selected by rotary switch. The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts. The strobe shall also feature selectable candela output, providing options for 15 or 15/75 candela when operating on 12 volts and 15, 15/75, 30, 75, 110, 115, 135, 150, 177 or 185 candela when operating on 24 volts. The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The speaker strobe shall be suitable for use in wet environments. RtN1IIfi1- Operating Temperature —40°F to 151°F(-40°C to 66°C) Dimensions, Wall-Mount . SPS Speaker Strobe 6.0"L x 5.0"W x 4.7"D (including lens and speaker) SP Speaker 6.0'L x 5.0"W x 2.9"D Dimensions,WaILMount Weatherproof Back Box 6.5'i x 5.5'H x 2.9"D lii- 1 Nominal Voltage (speakers) 25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) panels with built in sync) Operating Voltage with MDL Sync Module 9 to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz Power 1/4, ½, 1, 2 watts AVDSOIUO1 UL Current Draw Data Candela Derating w tul Current IDraw ZflI:liFi For K series products used at low 8 to 17.5 Volts 16 to 33 Volts temperatures, listed candela ratings must be Candela DC FWR DC FWR reduced in accordance with this table. a - -- I - Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 1 150 177 177 185 1185 Standard I lb I 123 I bb i (1 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Reverberant (dI3A @10 ft.) 2W 1W ½W 1/4 W Outdoor Speaker 90 87 84 81 Outdoor Speaker/Strobe 89 86 83 80 Dimensions Wall-Mount Outdoor Speaker Wall-Mount Outdoor Speaker Strobe AVDSCOOI fl Surface Mounting Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Ordering Information for SpectrAlert® Advance Outdoor Speakers and Speaker Strobes WIF'TI H. While Red Description SPWK° SPRK* Outdoor Speaker (includes plastic weatherproof back box) SPSWK*t SPSRK*t Outdoor Speaker Strobe, Standard cd (includes plastic weatherproof back box) SPSWK-CLR- - Outdoor Speaker Strobe, Standard cd, Clear Lens, ALERT Printed ALERT (includes plastic weatherproof back box) - SPSRHK Outdoor Speaker Strobe, High cd (135150177,185) (includes plastic weatherproof back box)____________ White Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box Notes: *Add "-R" to model number for weatherproof replacement device (no back box included), e.g., SPWK-R. Add "-P' to model number for plain housing (no "FIRE" marking on cover), e.g., SPSWK-P. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units, both the device and back box must be replaced. " aS)a5TEII'7 3825 Ohio Avenue • St. Charles, IL 60174 productspedficuf000subI 020 2 System Sensor, et notice. vtotoyoterrroencor.corc ISE1tLS3Rc Phone: 800-SENSOR2 • Fax: 630-377-6495 for 00000t product nforrootoc, orctudgtheiotestver000 of th dote sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17320-1653:0201 I Page 1 of 1 CATEGORY: 7320 -- SPEAKERS LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart©systemsensor.com DESIGN: Models SPR,SPW,SPRV, and SPWV SpectrAlert Speakers - Rectangular enclosure. ModelsPC\M SPCR, SPCWV and SPCRV SpectrAlert Speakers with round enclosure. Models SPSR, SPSRH,ISPSW,jSPSW-ALERT, SPSW-CLR-ALERT, *SPSWKCLRALERT SPSWH, SPSRV, and SPSVW SpectrAlert Speaker/Strobe with rectangular enclosure. Models SPSCR, SPSCRH,lSPSCW,l*SPSCWKCLRALERT, SPSCWH, SPSCRV, SPSCRVH, SPSCWV, and SPSCWVH SpectrAlert Speaker/Strobe with round enclosure. Model SPSCW-CLR-ALERT Speaker/Strobe. Model SPSW-ALERT has amber lens and is intended for non-fire use. All models identified are intended for indoor use mounted on the wall or ceiling. Models with an the suffix are suitable for indoor or outdoor use with an operating temperature rating of -40°C to +66°C (-40°F to +151°F) and have a NEMA 4X enclosure rating when used with models PWBB, PWBBW (wall) or the model PWBBCW (ceiling) plastic weatherproof back boxes or with Model MWBBW (Wall), MWBB (Wall) or MWBBCW (Ceiling) metal weatherproof back boxes. Models with a "- P' in the suffix have plain housings with no lettering on the enclosure. Models not containing "- P°, in the suffix have English lettering . reading "FIRE" on the housing. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Nominal Voltage: 25 Vrms or 70 Vrms Power Settings: ¼, 1/2, 1, 2 Watts Frequency Range: 400 - 4000 Hz INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as speaker/strobes when used with separately listed compatible fire alarm control units. Suitable for wall or ceiling mount. These speaker/strobes do not generate a distinctive three-pulse temporal code pattern (for total evacuation) as required per NFPA 72, 2010 edition. If required, the appliances must be used with a fire alarm control unit that can generate the temporal pattern signal. *Corrected 02-06-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR 5- Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrkertO Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. L, •)JJJjjJ Features • Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL sync module Listed for ceiling or wall mounting Agency Listings SIGNALING 1 C <e>MEA w LISTED APPROVED a PP roved 7125-1653 186 (indoor strobes) 7125.1653186 (horn strobes, S401 1 (chrrnes. horn strobes, horns) 3023572 M6A452-05-E chime strobes) S5512 (strobes) 7135.1653:189 (horns, chimes) The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. ri Arrhitp-t/Fnainpr Snifii-itinn General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit°° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SyncsCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also . control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/RNR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 "diameter x 2.2" high (180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, 6,9"diameter x 0.35'high (175 mm diameter x 9mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs, P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSQOSOI S S 11L Mc Stmbp Ctirrnt Draw In 8-17.5 Volts 16-33 Volts Candela DC FWR r_DC__j FWR Standard Candela Range I 15 123 128 1 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 DC Input 8-17.5 Volts 15 15/75 16-33 Volts 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. AVOSOO5O1 Dd) Ceiling back box skirt a. Ceiling-mount horn strobes I SpectrAlert Advance Dimensions SpectrAlert Advance Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2R* 2-Wire Horn Strobe, Standard cd, Red SCR Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red PC2W*t 2-Wire Horn Strobe, Standard cd, White SCW* Strobe, Standard cd, White PC2WH* 2-Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red Accessories PC4RH 4-Wire Horn Strobe, High cd, Red BBSC-2 Back Box Skirt, Ceiling, Red PC4W 4-Wire Horn Strobe, Standard cd, White Back Box Skirt, Ceiling, White TRC-HS Trim Ring, Ceiling, Red TRCW- Trim Ring, Ceiling, White HS Notes: Add "-F" to model number for plain housing (no "FIRE" marking on cover), e.g., P2R-P. t Add "-SF" to model number for "FUEGO" marking on cover, e.g., P2R-SP. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, g, 110, and 115 candela settings. "High cd" refers to strobes that include 135, ISO, 177, and 185 candela settings. 020 2 System Sensor. S}'S7EII.1 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject ge without notice. h/wit systerrrse050r.core Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information, orckdsag the latest version of this data sheet. .SENSOR' AVDS00501 .3, 12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17125-1653:0186 I Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart©systemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH,ISCWI SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177 *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Agency Listings I/IEA 53:187 (outdoor strobes) 7300-16 0 d APPROVED approve chime 7125-1653:188 (horn strobes. strobes) 3023572 MEA452.05.E 7135-1653189 (horns, chimes) SIGNALING W LISTED S4011 (chimes, hors strobes, horns) 03593 (outdoor and alert otrobos) SYSTEM SENSOR OutdoorSelectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpiectrA 160 Advance outdoor audible visible products are rich with features that cut installation times and SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40°F to 15°F Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that e:lsures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposng them to potential construction damage. Once the plates are mcunted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually el Tninate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devoes. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 3%-inch top anc bottom conduit entries and 3.4-inch knock-outs at the back. A screw-.n NPT plug with an 0-ring gasket for a watertight seal is included with each back box. maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from —40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Genera) SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuif° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115,135, 150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40°F to 151°F (-40°Cto66°C) . Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6'i x 4.7W x 2.5"D (142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7'W x 1.3D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1 x 2.0"D (145 mm L x 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVOSOI 201 Strobe .11l!11J1 Listed Candela Candela rating at -40°F 15 15/75 Do not use below 32°F 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Switch Sound SWltCfl auna VIJIIb Vulto nvvtiijcinnt nhletaiufl.. Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 . UL Current Draw Data UL Max~ Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard I 15 I 123 128 L66 I 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 8-175 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating candela ratings must be reduced in accordance with this table. For K series products used at low temperatures listed Horn Tones and Sound Output Data 8-17.5 16-33 . . ... 24-Volt Nominal tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AV0S01201 Wall-Mount Horn Strobes srproof Back Box SpectrAlert Advance Diagrams . Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK° 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*f 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RK 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) \ SRK*t SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HlRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-P' to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-F. f Add "-8" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, \NTP and \NTPW. "Standard cd" refers tic strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 5)'57'Eji7 ' ©20t2 System 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to cherge v,ittrout notice. Visit oyoter000000r.00 SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 tO curre,h prodOt ,,tororotono udcg the latest version of this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17300-1653:0187 I Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart©systemsensor.com DESIGN: ModelsISWK.ISWHK, SCWK, SCWHK, SRK, SRHK, SCRK and SCRHK strobe lights intended for indoor or outdoor use and may be mounted on the wall or the ceiling. These strobe lights are suitable for outdoor use at an operating temperature range of -40°F to 150°F (-40°C to 660C)* rating and are NEMA 4X rated when used with the Listed models SA-WBB (wall), SA-WBBW (Wall) or the model SA-WBBC (ceiling), SA-WBBCW (Ceiling) weatherproof back boxes. May be followed by suffix -P for plain housing with no lettering. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for general signaling. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. NOTE: Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Corrected 07-22-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DN-6935:D • H-202 FSP-851 (A) Series Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan® General Notifier FSP-851 (A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tofs address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851 T(A). The FSP-851 R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851 (A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACP5). FlashScan® (U.S. Patent 5,539,389) is a communication proto- col developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 360° viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pausej-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. NOTIFIER® by Honeywell I \ P/ FSP-851(A) in B2IOLP(A) Base - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. - B224B1(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851 (A), 0°C to 49°C (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F). Low temperature signal for FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.54°C). FSP-851 R(A) installed in a DNR(A)/DNRW, -20°C to 70°C (-4°F to 158°F). IJLJULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/ mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300pA @ 24VDC (one commu- nication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24 VDC ("ON"). Installation FSP-851 (A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1" (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. . - B501 (A): 4.1' (10.4 cm) diameter. - B200S(A): 6.875" (17.46 cm) diameter. DN-6935:D • 12/08/2011 - Page 1 of 2 sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S1 115. ULC Listed: Si 115 (FSP-851 A, FSP-851 RA, FSP-851 TA). MEA Listed: 225-02-E. FM Approved. CSFM: 7272-0028:0206. Maryland State Fire Marshal: Permit #2122. BSMI: C1313066760036. CCCF: Certif. # 2004081801000017 (FSP-851 T) Certif. #2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B21 OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B210LP(A)). ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low- profile. Fl 10BP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for 621 OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with 8501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. T55-127-01 0: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851 (A) only; box of 10. WCK-200B: White detector covers for use with FSP-851 (A) only; box of 10. Product Line Information NOTE: .4" suffix indicates ULC Listed model. FSP-851: Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A: Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F ' (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRAIDNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. B210LP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of 8501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases. -Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 93=1=1 •_ We cannot cover all specific applications or anticipate all requirements. MFIN &MMU1AC1Uitt All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6935:13 • 12/08/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. V272-0028-.02061 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywelI.com DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-8511F5P-851. I FSP851R* and FSP-851T photoelectric type smoke detectors. Models FSP-751T and FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-751T, FAPT-751, FAPT-851, FSP-851, FSP-851 R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air . velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division dn-6936:al •H-211 nf!b NOTIFIER® Intelligent Thermal (Heat) Detectors with FlashScan® by Honeywell General FST-851 Series Notifier FST-851 Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations. FST-851 Series thermal detectors use an innovative thermistor sensing circuit to produce 135°F/ 57°C fixed-temperature (FST-851) and rate-of-rise thermal detection (FST-851 R) in a low-profile package. FST-851 H pro- vides fixed high-temperature detection at 190°F/88°C. These thermal detectors provide effective, intelligent property protec- tion in a variety of applications. FST-851 Series detectors are compatible with all Notifier intelligent Fire Alarm Control Pan- els, except FireWarden series panels. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-851 R), 15°F (8.3°C) per minute. Factory preset at 135°F (57°C); high-temperature model at 190°F (88°C). Addressable by device. Compatible with FlashScan® and CLIP protocol systems. Direct dial entry of address 01 -159 for FlashScan® loops, 01-99 CLIP mode loops. Two-wire SLC connection. Visible LEDs "blink" every time the unit is addressed. 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identifica- tion. Remote test feature from the panel. Built-in functional test switch activated by external magnet. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Backward-compatible. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. Sealed against back pressure. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. SEMS screws for wiring of the separate base. Constructed of off-white Bayblend®, designed to commer- cial standards, and offers an attractive appearance. FST-851 Series in B7IOLP base 94-5V plastic flammability rating. Remote LED output connection to optional RA400Z remote LED annunciator. Optional sounder, relay, and isolator bases. Optional recessed (RMK400) or surface (SMK400E) base mounting kits. Specifications Size: 2.1" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in B501 base, 6.1" (15.5 cm) diameter installed in B71OLP base. Shipping weight: 4.8 oz. (137 g). Operating temperature range: FST-851 Series, FST-851 R: - 20°C to 38°C (-4°F to 100°F); FST-851 H: -20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% - 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (88°C). Altitude rating: 10,000 feet. ELECTRICAL SPECIFICATIONS: Voltage range: 15 - 32 volts DC peak tandby current (max. avg.): 300 pA © 24 VDC (one corn- unication every 5 seconds with LED enabled). ED current (max.): 6.5 mA © 24 VDC ("ON"). BASES AVAILABLE: B71OLP: 6.1" (15.5 cm) diameter. B501: 4.1" (10.4 cm) diameter. 6501 BH-2 or B501 BHT-2: Sounder base assembly. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). B224Bi Isolator Base: Dimensions: 6.2" (15.748 cm) x 1.2" (15.748 cm). Maximum: 25 devices between isolator bases. See Note 2 under Installation. Applications Use thermal detectors for protection of property. For further information, go to systernsensor.com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- dn-6936:al ° 06/8/09 - Page 1 of 2 S vides detailed information on detector spacing, placement, B501: Standard European flangeless base. zoning, wiring, and special applications. B501 (A): Standard European flangeless base, ULC Listing. Installation The FST Series plug-in intelligent thermal detector uses a sep- arate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. Suitable boxes include: 4.0 (10.16 cm) square box. 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. Single-gang box (except relay or isolator base). With B501BH-2 or B501BHT-2 base, use a 4.0" (10.16 cm) square box. With B224RB or B224Bl base, use a 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or a 4.0' (10.16 cm) square box. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S747 ULC Listed: 56978MEA Listed: 383-02-E FM Approved CSFM: 7270-0028:196 BSMI: 01313066760025 CCCF: Certif. #2004081801000018 U.S. Coast Guard: 161.002/23/3 (AFP-200); 161.002/27/3 (AFP1 010/AM2020); 161.002/42/1 (NFS-640) Lloyd's Register: 03/60011 Product Line Information "A" suffix indicates ULC Listed model. FST-851: Intelligent thermal detector. Must be mounted to one of the bases listed below. FST-851A: Same as FST-851 but with ULC Listing. FST-851R: Intelligent thermal detector with rate-of-rise feature. FST-851 RA: Same as FST-851 R but with ULC Listing. FST-851H: Intelligent high-temperature thermal detector. FST-851 HA: Same as FST-851 H but with ULC Listing. BASES: B71OLP: Standard U.S. low-profile base B71OLPBP: Standard U.S. low-profile base, pkg. of 10. 671 OLP: Standard U.S. low-profile base. B71OLP(A): Standard U.S. low-profile base. B501 BP: Standard European flangeless base, pkg. of 10 BH501BH-2: Sounder base, includes B501 base above. BH501 BHT-2: Same as B501 BH-2, but includes temporal sounder. BH501 BHA: Sounder base, includes B501 base above BH501 BHTA: Same as BH501 BHA, but includes temporal sounder. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: F110: Retrofit replacement flange for older style high profile bases. Converts bases for use with FlashScan® detectors. RA400Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. Supported by B71OLPBP(A) and B501 (A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501 (A) base only. RMK400: Recessed mounting kit. For use with B501 (A) base only. SMB600: Surface mounting kit for use with B71OLPBP(A). BCK-200B: Black detector covers, box of 10. M02-04-00: Test magnet. M02-09-00: Test magnet with telescope stick. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. T55-127-01O: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-ft. sections. Notifier® and FlashScan® are a registered trademark of Honeywell International Inc. Bayblend® is a registered trademark of Bayer Corp. ©2009 by Honeywell International Inc. All rights reserved, unauthorized use of this docu-ment is strictly prohibited. I so 9001 This document is not intended to be used for installation purposes . ______________ We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - dn-6936:al • 06/8/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17270-002870-1-96-1 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FST751I*851,I*851R, *..851H (fixed temperature) and FST-751R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: *Models FST-751, -751 R, -851, and -851 R = 135°F fixed temperature *Model FST-851 H = 190°F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Models B501 or B7IOLP base (CSFM Listing No. 7300-0028:173) and separately listed compatable fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 2-04-2003KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 1 7300-1653:0109 I Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, 1340213, B404B, 1340413T, B406B, B501, B501B, 14506587-002, B50IBH, B501BHT, B401BH, B110LP, B110RLP, B1IORLP750, B112LP, B114LP, B114LPBT, BII6LP and210LP detector baseL. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V* operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other E Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division df-50673:Rev • F-850 302 Series Rate-Anticipation Heat Detectors General The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8" (10.48 cm). Base diameter: 2" (5.08 cm). Electrical Ratings Voltage 6-125V0C Current 5amps 6-25VDC lamp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50' x 50' (15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. () Flre•LITeEALarms by Honeywell 1271pholjpg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-135/-194; 302-ET-135/-194; 302-135/-194) CSFM: 7270-0021:001 I27Idil .111 FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL 0.040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW DEVCON HERMETIC SEAL Cut-Away View df-50673: Rev • 02/03/09 - Page 1 of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-1 35 135°F All-Weather Vertical Mounting Note 2 below 302-AW-1 94 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-1 35 135°F Explosion Proof Mounting Note 4 below 302-EPM-194 194°F Explosion Proof Mounting AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4" outlet box. \ NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50' x 50' (15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to "THIN" or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 112"(1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. 4flIN &MN(IMC11RIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 - dl-50673:Rev • 02/03/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17270-0021:0001 I Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Thermotech lnc.,2900 North 1000 West, Ogden, UT 84414 Contact: A. Mark Headley (801) 782-2233 Fax (801) 782-1746 Email: thermotechinc@hotmail.com DESIGN: Models 302, 302H, 302AW, 302ET and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. ModelsI30271or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-ET and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. *Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Rv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division N MM-I (A)FMM-1 01(A), FZM-1 (A) &FDM-1 (A) DN-6720:C • H-220 NOTIFIER® Monitor Modules with FlashScan® - by Honeywell rn I General Four different monitor modules are available for Notifiers intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [1 0.16 cm] square box) that supervises either a Style D (Class or Style B (Class B) circuit of dry-contact input devices. FMM-1 01 (A) is a miniature monitor module a mere 1.3 (3.302 cm) H x 2.75° (6.985 cm) W x 0.5 (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101 (A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FMM.1(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 (A) can be used to replace MMX-1 (A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class 1: I ° 0 FMM-1(A) (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:C • 10/06/2010 - Page 1 of 4 S FMM.101(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. 1415 0 1 ADDRESS 0 1 ) 3 03 ) LOOP 1 3rr 2! 10 5 8 7 6 1 8 76 TENS ONES h.- o 1w •o LU •.q -j The FMM-1 01(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). Dimensions: 1.3 (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65' (1.651 cm) deep. Wire length: 6' (15.24 cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops, 01 —99 on CLIP loops. LED flashes during normal operation; this is a programma- ble option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1 (A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. FMM-101(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): Nominal operating voltage: 15 to 32 VDC. DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms I Average operating current: 350 pA, 1 communication every I maximum. Current: 90 mA per module maximum. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Temperature range: 32°F to 120°F (0°C to 49°C). Sflnrtern Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Page 2 of 4 - DN-6720:C • 10/06/2010 Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDMI(A) Dual Monitor Module . The FDM-1 (A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) JOC circuits ONLY Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Averaae ooeratina current: 750 uA (LED flashin. Maximum IDC wiring resistance: 1,500 ohms Maximum iDC Voltage: 11 Volts. Maximum iDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125° (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1 (A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically . assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. —161.002/23/3 (AFP-200: FMM-1/-101, FZM-1) - 161.002/42/1 (NFS-640: FMM-1/- 101) Lloyd's Register: —03/60011/El (FMM-1/-101, FZM-1) - 94/60004/E2 (AFP-200: except FOM- 1) - 02/60007 (NFS-640: FDM-1) FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-1 01(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:0219 MEA: 457-99-E U.S. Coast Guard: DN-6720:C • 10/06/2010 - Page 3 of 4 DN-6724:B3 NOTIFIER® by Honeywell AV ICE tP,/"I -) * FCM-1(A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1 (A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1 (A) \~4 FCM-1 (A) & FRM-1 (A) Series Control and Relay Modules General FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFl). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audibleMsual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScanO releasing applications. Normal ooeratlna voitaae: 15 to 32 VDC Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01 -159). Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:53 • 2/17/2011 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T1O and Til): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (Aversion only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM.1 (A) Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5A 30 VDC Inductive Coded (UR=5ms) 1A 30 VDC Inductive Coded (LJR=2m5) .3A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed mode!. FCM-1(A): Intelligent Addressable Control Module. FRM-1 (A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1 (A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM- 1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I Is0 00i We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I I 11111111110111111 & 111INGIM131111119 All specifications are subject to change without notice. I I QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-6724:133 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0. FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17300-0028:0219 I Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface FSM-101,IFDM-1, I _module,IFMM-1,_FMM-101jFZM-1, FTM-1 monitor modules, FCM-1,IFRM-1_ontrol modules, and *FDRM1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RVC operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTEM 4 SENSOR Intelligent Non-Relay Photoelectric Duct Smoke Detector The lnnovairFlex°° Series are the only duct smoke detectors flexible enough to fit configurations frorre".10 J square to rectangular and everything in between. Features Photoelectric, integrated low-flow technology (detector head sold separately) Air velocity rating from 100 fit/min to 4,000 ft/mm Adjusts to square and rectangular mounting configurations Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented tool-free, plug-in sampling tubes New cover tamper signal Increased wiring space with a new 1/4-inch conduit knockout Housing has space for mounting a relay module Easily accessible ccde wheels on sensor head (sold separately) Clear cover for convenient visual inspection UL 268A listed Remote testing capability Requires corn line jower only NEMAType 4 UL listed for non-hazardous indoor and outdoor applications (DNRW only) UV-resistant, UL-listed housing and cover material (DNRW only) Agency Listings & X <~> MSFM • LISTED 2911 APPROVED 3029700 3242.1653.209/210 approved 2125 The InnovairFIex Series DNR and DNRW are intelligent (addressable) non-relay photoelectric duct smoke detectors. Like all InnovairFIex detectors, the DNR and DNRW both feature an adjustable housing design that fits square and rectangular installation footprints, mounts to both round and rectangular ductwork, and utilizes tool-free, plug-in sampling tubes for increased application flexibility and installation ease. These units sense smoke in challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). For even more extreme environments like rooftops, the DNRW's NEMA 4-rated watertight and UV-resistant housing protects against windblown dirt and dust, rain, and hose directed water, enabling it to be installed without a costly enclosure, saving time and money. The InnovairFiex housing cover isolates the sensor head from the low-flow feature for simple maintenance, and a cover tamper feature initiates a trouble signal for a removed or improperly installed sensor cover.The housing also provides a 1/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module to meet specific application requirements. These detectors can be customized to meet local codes and specifications without additional wiring. The InnovairFiex line is compatible with all previous Innovair models, including remote test accessories, for easy retrofits. WARNING: Duct smoke detectors have specific limitations. I '~Or InnovairFiex Duct Smoke Detector Specifications L121tT1VAaiI! rn--.r1iT1r.i.s. The air duct smoke detector shall be a System Sensor lnnovairFlex°° DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA 4 Duct Smoke Detector. The detector housing shall be UL listed per DL 268A specifically for use in air handling systems.The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4,000 ft/mm (0.5 m/sec to 20.32 m/sec).The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS1 51 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Size: (Rectangular) (Square) 14.38 in (37 cm) Length; Sin (12.7cm) Width; 2.5 in (6.6 cm) Depth 7.75 in (19.7cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA 4 (DNRW only) Operating Temperature Range: —4°F to 158°F (-20°C to 70°C) Storage Temperature Range: —22°F to 158°F (-30°C to 70° C) Operating Humidity Range: 0% to 95% relative humidity (non-condensing) Air Duct Velocity: 100 to 4,000 ft/mm (0.5 to 20.32 m/s) DCOIL (if included): 17.5— 26.4 VDC, 93 mA max Please see detector head installation manual for electrical specifications Accessory Current Loads at 24 VDC 4. ~a. Device Standby Alarm RA100Z OmA 12mAMax. RT5151/RTS151KEY OmA 12mAMax. 0 Installing the InnovairFiex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). Wiring for Intelligent Non-Relay Duct Smoke Detector System wiring diagram for DNR: COMM. LINE(-i-) COMM. LINE I I COMM. I LINE(-) u I I I UL/FM LISTED 1ST 2ND CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP DNRtoRA100Z: + RA -*f RA100Z (-) I REMOTE ALARM LED OPTION 1 PER UNIT DNR to RTS1S1/RTS151KEY with "R" Remote Test Capable Detector Head Option: TEST COIL+ TEST COIL— RTS151/RTS151KEY COMM+ OUT (CONV ONLY) + —i Q P comm :JUMPER RA/RTS - L -'3 - RA+Q RTS+ DNR to RTS1 51/RTS151 KEY with DCOIL Option: TEST COIL+ TEST COIL- 4~— COMM+ OUT (CONV ONLY) + COMM— RTSI5I/RTS151 KEY REMOTE TEST STATION RNRTS — RA+ LED OPTION 1 PER UNIT RTS + TEST COIL OPTION 1 PER UNIT 95 mA CURRENT DRAW important Notes The use of either the RTS1 51 or RTS1 51 KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the DNR or DNRW installation manual for more information. The RTS1 51/RTS1S1KEY test coil circuit requires an external 24VDC power supply which must be UL listed. A05.0422.005 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. II L J LJ LJ I RTS151 ULS25221 RTSI51KEVULS2522 RA100ZULS2522 Ordering Information IThI[,. DNR Intelligent non-relay photoelectric low-flow duct smoke detector DNRW Watertight intelligent non-relay photoelectric low-flow duct smoke detector Accessories DCOIL Remote test coil required with RTS451/RTS451 KEY/RTS151/RTS151 KEY DST1 Metal sampling tube duct width up to 1 ft (03m) DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (03 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DSTS Metal sampling tube duct widths 4 f to 8 ft (1.2 to 2.4 m) DST1 0 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 ml P48-21-00 End cap for metal sampling tubes ETX Metal exhaust tube duct width lft 10.3 ml M02-04-00 Test magnet RA100Z Remote annunciator alarm LED RTS1 51 Remote test station RTS1 51 KEY Remote test station with key lock DH4000E-1 Weatherproof enclosure 557E,7 3825 Ohio Avenue. St. Charles, IL 60174 prodpeorn,bi 02 IOSysten-rSen... ee.wtswem,en,o,conw, current pmdua info-ati.n, inducing the atest wnion ofthis data sheet Phone: 800-SENSOR2• Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 13242-1653:0209 I Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trishiinhart@systemsensor.com DESIGN: Models =DNR DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-23-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: 17300-1657212 I Page 1 of I 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com Models lRTS151 ,1RT5151 KEY and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. Refer to the installation manuals. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 11 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys BUsiness card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 14deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information wJ 1:. J FAD ACE-li FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. M ____ ___ISO9001 ON [1 - REGISTERED . NFPA COMPANY Made In U.S.A. .1 Space Age Electronics, Inc. 2009 E00549 LT10559 Rev.D 1/2 Space Age Electronics, Inc. www.tsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! "'-""SPACE AGE . ' ELECTRONICS, INC.. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with I" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall N not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector 0 ttormation Minimum Required Documentation (SIG-FUN) rnseodApprnvain eEoc - m IflStOIIato, C00000rnr oily Hauing Jutiudiution I,CO,a.Ot%.,oc,riIo tintotntatinn Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. www.lsae.com . 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 JCW-i (12,06 SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to mod(,i5i this form as needed to provide a more complete and/or clear record Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record Form Completion Date: 11/11/2016 Supplemental Pages Attached: PROPERTY INFORMATION Name of property: St. Patrick Parish School Address: 3820 Plo Pico Drive, Carlsbad, CA 92008 Description of property: A3, E (Private School) Name of property representative: St. Patrick Parish Address: 3820 Pio Pico Drive, Carlsbad, CA 92008 Phone: Fax: E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Low Voltage Integrated Systems Address: 1930 Watson Way, Ste L, Vista, CA 92008 Phone: 760-598-4110 Fax: 760-598-4108 E-mail: mikea@sdlvis.com Service organization: Same Address: Phone: Fax: E-mail: Testing organization: Same Address: Phone: Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: National Monitoring Center Address: Phone: 1-800-662-1711 Fax: E-mail: Account number: A15-8889 Phone line 1: Phone line 2: Means of transmission: Cell Communicator Entity to which alarms are retransmitted: Carlsbad Fire Dept. Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: DESCRIPTION OF SYSTEM OR SERVICE This is a: New system U Modification to existing system Permit number: FA1 60032 NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: Notifier Model number: NFS2-640 4.2 Software and Firmware Firmware revision number: 24 4.3 Alarm Verification 0 This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. - (p. 1 o13) SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120VAC Overcurrent protection: Type: Circuit Breaker Branch circuit disconnecting means location: Panel 1, Next to FACP Control panel amps Amps: 20 Number: 40 5.4 5.1.2 Secondary Power Type of secondary power: Battery Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 15 5.2 Control Unit E This system does not have power extender panels Power extender panels are listed on supplementary sheet A R CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line X B 1 Device Power X B 1 Initiating Device X B 1 Notification Appliance X B 1 Other (specify): REMOTE ANNUNCIATORS Type Location FDU-80 Admin. Bldg. Reception Hallway INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 1 Addressable Alarm Contact Smoke Detectors 63 Addressable Alarm Photoelectric Duct Smoke Detectors 9 Addressable Supervisory Photoelectric Heat Detectors 5 Addressable Alarm Thermal Gas Detectors Waterfiow Switches 1 Addressable Alarm Contact Tamper Switches 3 Addressable Supervisory Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 2of3) SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible 11 Speaker Visible 4 Strobe Combination Audible and Visible 56 Speaker/Strobe - SYSTEM CONTROL FUNCTIONS Type Hold-Open Door Releasing Devices 1-IVAC Shutdown 9 Fire/Smoke Dai Door Unlockinl Elevator Recall Elevator Shunt Trip 1 INTERCONNECTED SYSTEMS Z This system does not have interconnected systems. E] Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system ;,~ sc,red em has been installed according to all NFPA standards cited herein. Signed: ________ Printed name: Nick Truman Date: 11/11/2016 Organization: Low Voltage Integrated Sys. Title: Fire/Life Safety Tech Phone: 760-598-4110 12.2 System Operational Test This system as scj,d he has tested according to all NFPA standards cited herein. Signed: Printed name: Nick Truman Date: 11/11/2016 Organization: Low Voltage Integrated Sys. Title: Fire/Life Safety Tech. Phone: 760-598-4110 12.3 Acceptance Test Date and time of acceptance test: \ f j.( i I (y ~ -- ~, Installing contract( Testing contractor Property represent AHJ representative Copyright @ 2012 Nations. Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 3of3) EMERGENCY COMMUNICATIONS SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION This form is a supplement to the System Record of Completion. It includes systems and components specific to emergency communications systems. This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Form Completion Date: 11/11/2016 Number of Supplemental Pages Attached: PROPERTY INFORMATION Name of property: St. Patrick Parish School Address: 3820 Pio Pico Drive, Carlsbad, CA 92008 DESCRIPTION OF SYSTEM OR SERVICE El Fire alarm with in-building fire emergency voice alarm communication system (EVAC) 0 Mass notification system Z Combination system, with the following components: Fire alarm E EVACS El MNS 0 Two-way, in-building, emergency communications system D Other (specify): NFPA 72 edition: 2013 Additional description of system(s): 2.1 In-Building Fire Emergency Voice Alarm Communications System Manufacturer: Notifier Model number: NFS2-640 Number of single voice alarm channels: 1 Number of multiple voice alarm channels: 5 Number of speakers: 67 Number of speaker circuits: Location of amplification and sound processing equipment: In FACP Cabinet Location of paging microphone stations: Location I: Admin Office Location 2: Location 3: 2.2 Mass Notification System 2.2.1 System Type: El In-building MNS—combination El In-building MNS El Wide-area MNS 0 Distributed recipient MNS El Other (specify): Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 1 of 3) EMERGENCY COMMUNICATIONS SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION (continued) DESCRIPTION OF SYSTEM OR SERVICE (continued) 2.2.2 System Features: LI Combination fire alarm/MNS LI MNS autonomous control unit LI Wide-area MNS to regional national alerting interface LI Local operating console (LOC) LI Distributed-recipient MNS (DRMNS) LI Wide-area MNS to DRMNS interface LI Wide-area MNS to high power speaker array (HPSA) interface LI In-building MNS to wide-area MNS interface 0 Other (specify): 2.2.3 MNS Local Operating Consoles Location I: Location 2: Location 3: 2.2.4 High Power Speaker Arrays Number of FIPSA speaker initiation zones: Location I: Location 2: Location 3: 2.2.5 Mass Notification Devices Combination fire alarm/MNS visual devices: Textual signs: Other (describe): Supervision class: MNS-only visual devices: 2.2.6 Special Hazard Notification This system does not have special suppression predischarge notification. 0 MNS systems DO NOT override notification appliances required to provide special suppression predischarge notification. TWO-WAY EMERGENCY COMMUNICATIONS SYSTEMS 3.1 Telephone System Number of telephone jacks installed: Number of warden stations installed: Number of telephone handsets stored on site: Type of telephone system installed: LI Electrically powered LI Sound powered 3.2 Two-Way Radio Communications Enhancement System Percentage of area covered by two-way radio service: Critical areas % General building areas % Amplification component locations: Inbound signal strength dBm Outbound signal strength dBm Donor antenna isolation is dB above the signal booster gain. Radio frequencies covered: Radio system monitor panel location: Copyright © 2012 National Fire Protection Association, This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 2of3) EMERGENCY COMMUNICATIONS SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION (continued) TWO-WAY EMERGENCY COMMUNICATIONS SYSTEMS (continued) 3.3 Area of Refuge (Area of Rescue Assistance) Emergency Communications Systems Number of stations: Location of central control point: Days and hours when central control point is attended: Location of alternate control point: Days and hours when alternate control point is attended: 3.4 Elevator Emergency Communications Systems Number of elevators with stations: Location of central control point: Days and hours when central control point is attended: Location of alternate control point: Days and hours when alternate control point is attended: -- - 3.5 Other Two-Way Communications System Describe: CONTROL FUNCTIONS This system activates the following control functions specific to emergency communications systems: Qua Mass Notification Override of Alarm Signaling Systems or Appliances See Main System Record of Completion for additional information, certifications, and approvals. Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 3of3) NOTIFICATION APPLIANCE POWER PANEL SUPPLEMENTARY RECORD OF COMPLETION This form is a supplement to the System Record of Completion. It includes a list of types and locations of notification appliance power extender panels. This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Form Completion Date: 11/11/2016 Number of Supplemental Pages Attached: PROPERTY INFORMATION Name of property: St. Patrick Parish School Address: 3820 Pio Pico Drive, Carlsbad, CA 92008 NOTIFICATION APPLIANCE POWER EXTENDER PANELS See Main System Record of Completion for additional information, certifications, and approvals. Copyright © 2012 Nationa Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 1 of 1)