Loading...
HomeMy WebLinkAbout4625 RED BLUFF PL; ; FPC2017-0012; PermitF 11ISJI Fi *I] F4I Cr'cityof Cdflsbad IAUG EftIIUu Print Date: 09/27/2022 Permit No: FPC2017-0012 Job Address: 4625 RED BLUFF PL, CARLSBAD, CA 92010-4671 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 01/09/2017 Valuation: $0.00 Lot #: Issued: 01/24/2017 Occupancy Group: Project #: Finaled Close Out: 04/20/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Wong, Cindy Plan Check U: Project Title: Description: GODDARD SCHOOL -ALARM TI FPContractor: THE STEINHILBER CORPORATION 533 S VINEWOOD ST ESCONDIDO, CA 92029-1924 (760) 747-3050 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Nfirml EHcmpapmoEs FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS THE GODDARD SCHOOL TENANT IMPROVEMENT 4625 RED BLUFF PLACE CARLSBAD, CA 92010 FIRE ALARM SYSTEM MPTERiALDATASHEETS-j The Goddard School Tenant Improvement 4625 Red Bluff Place Carlsbad, CA 92010 FIRE ALARM SYSTEM BILL OF MATERIALS WHEELOCK EXCEDER HSC/STC - CEILING MOUNTED HORN/STROBES & STROBE CSFM# 7125-0785:0168 COOPER Notification 1- Save up to 480/6 in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of lnstallatlon** Sleek Modern Aesthetics Finger Slide Switches Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB 8 Candela Settings %fl wail - 15/1575/30/75/95/110/135/185 ceiling - 15/30/60/75/95/115/150/177 I Universal Mounting Base Ceiling and wall Mounts to 5 Backbox Types EZZCE~D_I Strobe, Horn Strobe, and Horn Notification Appliances Description: The Wheelock® ExcederrM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® ExcederlM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Environmentally Friendly Low Current Draw Compatibility and Requirements Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Compatible with UL "Regulated Voltage using filtered VOC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the Regulated Voltagerarige Compared to competitive models Patented Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol At All warnings are printed In bold capital letters! A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWWCOOPERNOT1FICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their 'Regulated Voltage Range. All candela ratings represent minimum effective strobe Intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32F to 120'F (0C to 49'C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Low ACurrent 1111 PA' 1Fewer Power Supplies Strobe Ratings per UL Standard 1971 UL Max Current* 24 VDC /24FWR 12 VDC Model Regulated Voltage Range VDC 15/75 30 60 75, 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 STC 80330 r 0.085 0.103 0.163 -0.1 82 - 0.205 0.253 -0.110 - Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC UL Max Current* at =dBA l RegulatedVoltage 15 15/75 30 60 95 110 115 135 150 177 VDC 185Range -Mode 24VDC M0.125 8.0-33.0 0.082 0.095 0.102 0. 0.176 0.197 0.242 0.282 80330 0082 -77 0102 0141 6 0197 0242 0282 N••E Max Current* at Anechoic 95 dBA 24VDC 12VDC Model Regulated 15 15/75 130 60 95 110 115 135 150 177 185 15 15/75 Rang HS 80330 0.073 0.083 0.087 0.139 0.163 0186 0230 0.272 0.122 0.153 HSC 80330 0.073 V?l87J 01 0139 163 0.186 0.230 0.272 0.122 EMax Current* at Anechoic 90 dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL Anechoic - Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 RN 8.0-17.5 0.047 0.026 0.07 ]0.0117 HNC 8.0-17.5 0.047 0.026 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync WI Strobe DSM or Mounting Model Candela Wheelock Power 12/24VDC* Options Supplies HSR 15/1575/30/75/95/110/135/185 X X LIMB** HSW 15/1575/30/75/95111011351185 X X UMB** HSRC 15130/60/75/95/115/1501177 X X X X UMB** UMB** HSWC 15/30/60175/95/11511501177 STR 15/1575/30175/95/1101135/185 X X UMB** STW 15/1575130/75/951110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** ST\NC 15/30/60/75/95/115/150/177 X X X UMB** UMB** HNR X HNW X X X 17 UMB** UMB** HNRC X HNWC X X UMB** NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6/11 Wheelock* tMEDCJ SAFEPATH WAV Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION MIMI OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 25-07851 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Model trobe ffodelo-IS rn strobe and HN horn. Model ST is a synchronous and non-synchronous scrcse light. a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). AdditionaIlygac'nay be added for ceiling models and/or a -NR may be added for non-resettable mods'Ft'non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division