Loading...
HomeMy WebLinkAbout2426 TOWN GARDEN RD; BLDG 14; FPC2017-0381; Permit?ER]tT REPORT Hag pgmn Print Date: 09/27/2022 Permit No: FPC2017-0381 Job Address: 2426 TOWN GARDEN RD, CALRSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132601000 Track #: Applied: 12/21/2017 Valuation: $8,244,261.35 Lot : Issued: 01/22/2018 Occupancy Group: Project #: DEV2016-0015 Finaled Close Out: 04/14/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check#: INSPECTOR: Plan Check #: Project Title: VIASAT BRESSI RANCH CAMPUS Description: VIASAT BUILDING 14 -FIRE ALARM Applicant: FPContractor: PYRO-COMM SYSTEMS INC PYRO-COMM SYSTEMS INC CHARLES KRETZING 15531 CONTAINER LN 5115 AVENIDA ENCINAS, #G HUNTINGTON BEACH, CA 92649-1530 CARLSBAD, CA 92008-4387 (714) 902-8000 (760) 930-6014 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Pyro-Comm Systems, Inc. 5115 Avenida Encinas, Suite G C10 #612153 Carlsbad, CA 92008 (760) 930-6014 Fax (760) 930-6015 ViaSat Cold Shell Bldg 14 Fire Alarm System Submittal MFG. MODEL # DESCRIPTION CSFM Notifier NFS-320 Control Panel 7165-0028:0243 Notifier UDACT Communicator 7165-0028:0243 Notifier BAT-12260 Batteries N/A Notifier NFS-LBB Battery Backbox N/A Spaceage SSU00685 Document Cabinet N/A Notifier FSP-851 Photo Smoke Det. 7272-0028:0206 Notifier B21OLP Base 7300-1653:0109 Notifier NBG-12LX Pull Station 7150-0028:0199 Notifier FDM-1 Dual Monitor Module 7300-0028:0219 Notifier FMM-1 Monitor Module 7300-0028:0219 Sys. Sensor P2WL Wall Horn/Strobe 7135-1653:0503 12/21/17 Job #2017596 FS-320( E) Intelligent Addressable Fire Alarm System General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement. The NFS-320's modular design makes system planning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to pro- tect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. For installations using NFS-320C, an optional ACM Series annunciator can be mounted in the same cabinet (up to 48 zones/points, order separately; see DN-60085). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless called out with a version-specific "R", "C' or 'F' at the end of the part number, 'NFS -320" refers to models NFS-320, NFS-320R, NFS-320C, and NFS-320E. Features Certified for seismic applications when used with the appro- priate seismic mounting kit. Approved for Marine applications when used with listed compatible equipment (see DN-60688). One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 0r7. Up to 159 detectors (any mix of ion, photo, thermal, or multi- sensor) and 159 modules (Addressable pull stations, nor- mally open contact devices, two-wire smoke, notification, or relay). 318 devices maximum. Standard 80-character display. Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYXWorks, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYX- Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- 300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC is used in network paging. 6.0 A power supply with four Class NB built-in Notification Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. Autoprogramming and Walk Test reports. Optional universal 318-point DACT. 80-character remote annunciators (up to 32). ElA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column printers). History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. DN-7112:H •A-14 NOTIFIER® by Honeywell FS-32O Alarm Verification selection per point, with tally. Presignal/Positive Alarm Sequence (PAS). Silence inhibit and Auto Silence timer options. NAC coding functions: - March time. - Temporal. - California two-stage coding. - Canadian two-stage. - Strobe synchronization. Field-programmable on panel or on PC, with VeriFire® Tools program check, compare, simulate. Full QWERTY keypad. Battery charger supports 18 —200 AH batteries. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Automatic time control functions, with holiday exceptions. Extensive, built-in transient protection. Powerful Boolean logic equations. FLASHSCANO INTELLIGENT FEA TURES Poll up to 318 devices in less than two seconds. Activate up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - nine levels. Pre-alarm ONYX intelligent sensing - nine levels. Day/Night automatic sensitivity adjustment Sensitivity windows: - Ion - 0.5 to 2.5%/foot obscuration. - Photo —0.5 to 2.35%/foot obscuration. - Laser (VIEW®) - 0.02 to 2.0%/foot obscuration. - Acclimate® PIusTM - 0.5 to 4.0%/foot obscuration. - IntelliQuad - 1.0 to 4.0%/foot obscuration. - InteIIiQuadTM PLUS - 1.0 to 4.00/o/foot obscuration Drift compensation (U.S. Patent 5,764,142). DN-71 12:H • 08/09/2012 - Page 1 of 6 Degraded mode - in the unlikely event that the NFS-320's primary microprocessor fails, FlashScan detectors revert to degraded operation and can activate the control panel's NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. FSL-751 VIEW (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Revolutionary spot laser design. Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the fire location. No moving parts to fail or filters to change. Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE® PLUSTM LOW-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels without oper- ator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. FlashScan or CLIP ('classic") mode compatible. Low-temperature warning signal at 40°F ± 5°F (4.44°C ± 2.77°C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. Six sensitivity levels. FCO-851 INTELLIQUADTM PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. Six sensitivity levels. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). Low-pressure CO2 listed. VOICE FEATURES Integrates with FireVoice-25/50 Series (see DN-7004). Integrates via serial connection with FireVoice-25/50ZS Series (see DN-7003. HIGH-EFFICIENCY OFFLINE SWITCHING 3.0A POWER SUPPLY (60A IN ALARM) 120 VAC (NFS-320/NFS-320C); 240 VAC (NFS-320E). Displays battery current/voltage on panel (with display). Up to 32 Remote I Displays SLC Intelligent Loop J~l 111 E - IntelliQuad"'' FAPT-851 Acclimate Plus"CJ FSL-751 FlashScantfl VIEW® NBG-12LX FMM1 FRM1 XP6I1O il FSP-851 FlashScan® photo I/O Modules FDUSO etc. LCD2-80 LCD2-80 IDC Relay Contact I I ElA485 2048 annunciator/control points U IN E ACM-BR ACMIAEM-24AT LDM-32 I FS 320 Relay Control LED Annunciator Custom Graphics Optional 318 point UDACT Dual phone 10 lines to Central Station I Sample System ElA-232/L \ Options EEEEEEEE I PRN Series Printer 711250k.wmt Page 2 of 6— DN-71 12:H • 06/09/2012 I FlashScan, Exclusive World-Leading Detector Protocol At the heart of the NFS-320 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashS- can is an all-digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this new protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS-320 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS-320 with industry-leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high- speed microcomputer used by the NFS-320. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indica- tive of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre- alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self- restoring, and can be used to activate special control functions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self- Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to con- sider readings from nearby sensors in making alarm or pre- alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram. This timesaving feature is a special software routine. The FACP "learns" what devices are physically con- nected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protec- tion in a new installation, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS-320, like all NOTIFIER intelligent panels, has the exclusive feature of pro- gram creation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS-320 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS-320 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an off line programming and test utility that can greatly reduce installation programming time, and increase con- fidence in the site-specific software. It is Windows®-based and provides technologically advanced capabilities to aid the installer. The installer may create the entire program for the NFS-320 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS-320's flexible system design. Wiring: When designing the cabinet layout, consider separation of power-limited and non-power-limited wiring as discussed in the NFS-320 Installation Manual. It is critical that all mounting holes of the NFS-320 are secured with a screw or standoff to ensure continuity of Earth Ground. Networking: If networking two or more control panels, each unit requires a Network Control Module or High-Speed Net- work Control Module (HS-NCM can support two nodes; see "Networking Options" on page 4). These modules can be installed in any option board position (see manual), and addi- tional option boards can be mounted in front of them. KDM.R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout). 12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled; Control Active; Abort; Pre-Discharge; Discharge. Keypad Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED back- light. Product Line Information "Configuration Guidelines" on page 3 "Networking Options" on page 4 "Auxiliary Power Supplies and Batteries" on page 4 "Audio Options" on page 4 "Compatible Devices, ElA-232 Ports" on page 4 "Compatible Devices, EIA-485 Ports" on page 4 "Compatible Intelligent Devices" on page 4 "Enclosures, Chassis, and Dress Plates" on page 5 "Other Options" on page 5 CONFIGURATION GUIDELINES The NFS-320 system ships assembled; description and some options follow. See "Enclosures, Chassis, and Dress Plates" on page 5 for information about mounting peripherals. NOTE: Stand-alone and network systems require a main display. On stand-alone systems, the panel's keypad provides the required display. On network systems (two or more networked fire panel nodes), at least one NCA-2, NCS, or ONYX Works annunciation device is required. INOS-320: The standard, factory-assembled NFS-320 system includes the following components: one control panel mounted on chassis (120 V operation - ships with grounding cable, bat- tery interconnect cables, and document kit); includes integral power supply mounted to the main circuit board; one primary display KDM-R2 keypad/display; and one cabinet for surface or DN-71 12:H • 08/09/2012 - Page 3 of 6 I [1 I I I 'Ii I I semi-flush mounting. Purchase batteries separately. One or two option boards may be mounted inside the NFS-320 cabinet,- additional option boards can be used in remote cabinets. NFS-320R: Same as NFS-320 above, but in red enclosure. NFS-320C: Based on NFS-320 above. NFS-320C supports installation of an optional ACM-series annunciator in the same cabinet. UL- and ULC-listed. NFS-320CR: Same as NFS-320C but in a red enclosure. NOTE: For additional information on NFS-320C, see DN-60085. NFS-320E: Same as NFS-320 above, but with 240 V operation. TR-320: Trim ring for the NFS-320 cabinet. NETWORKING OPTIONS NCM-W, NCM-F: Standard Network Communications Modules. Wire and multi-mode fiber versions available. See DN-6861. HS-NCM-W/MF/SF/WMFIWSF/MFSF: High-speed network communications modules. Wire, single-mode fiber, multi-mode fiber, and media conversion models are available. See DN- 60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 A or 10 A addressable charging power supply. See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and trans- fer relay, and overcurrent protection. Mounts on two of four posi- tions on a CHS-4L or CHS-4 chassis. See DN-5952. FCPS-24S61S8: Remote 6 A and 8 A power supplies with bat- tery charger. See DN-6927. BAT Series: Batteries. NFS-320 uses two 12 volt, 18 to 200 AH batteries. See DN-6933. AUDIO OPTIONS NFV-25/50: 25 watt, 25 VRMS, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, and sing le-/dualchannel Class A or Class B speaker circuits. See DN-7004. NFV-25/50DA: Single channel, 25 Watt, 25 VRMS, emergency voice evacuation panel. See DN-60048. NFV-25/50DAZS: Single channel, 25 Watt, 25 Vrms, emergency voice evacuation panel. Can be automatically activated via the Zone System serial communication link from the NFV-25/50ZS. See DN-60049. NFV-25150ZS: 25 watt, 25 Vrms, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, zone splitter module (ACC-ZSM), zone page module with keypad (ACC-ZPMK). See DN-7003 NFV-25/50ZST: 25 watt, 25 Vrms, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, zone splitter module (ACC-ZSM), zone page module with keypad (ACC-ZPMK). See DN-60337. COMPATIBLE DEVICES, EIA -232 PORTS PRN-6: 80-column printer. See DN-6956. V54095/5: Printer, 40-column, 24 V. Mounted in external back- box. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extend- ing serial data links to remotely located FACP5 and/or peripher- als; mount on NFS-320 chassis. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by pow- ered-up switch selection) by point to be red, green, or yellow; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. LCD-80: ACS mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See LCD-80/-80TM (DN-3 198). FDU-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-6820. LCD2-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-60548. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32; remote custom driver modules. See DN-0551. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS-8L, SCE-8L; eight (expandable to 16) circuits. See ON- 48 18. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit; mount on NFS-320 chassis or remotely. See DN-6860. UDACT: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-4867. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides posi- tive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). Mounts in BB-UZC. See DN-3404. COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receiver unit of FSB-200(S) below. See DN-6985. BEAMHRK: Heating kit for use with the reflector of FSB-200(S) below. See DN-6985. BEAMLRK: Long-range accessory kit, FSB-200(S) below. See DN-6985. BEAMMRK: Multi-mount kit, FSB-200(S) below. See DN-6985. BEAMSMK: Surface-mount kit, FSB-200(S) below. See ON- 6985. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-200S: Intelligent beam smoke detector with integral sensi- tivity test. See DN-6985 FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria Detec- tor. See DN-604 12. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite- ria Fire/CO Detector. See DN-60689. FSI-851: Low-profile FlashScan ionization detector. See ON- 6934. Page 4 of 6- DN-71 12:H • 08/09/2012 I FSP-851: Low-profile FlashScan photoelectric detector. See DN-6935. FSP-851 T: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FSP-851 R: Remote-test capable photoelectric detector for use with DNR(W) duct detector housings. See DN-6935. FST-851: FlashScan thermal detector 135°F (57°C). See DN-6936. FST-851R: FlashScan thermal detector 135°F (57°C) with rate- of-rise. See DN-6936. FST-851H: FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. FAPT-851: FlashScan Acclimate Plus low-profile multi-sensor detector. See DN-6937. FSL-751: FlashScan VIEW laser photo detector. See DN-6886. DNR: InnovairFIex low-flow non-relay duct-detector housing (order FSP-851 R separately). Replaces FSD-751 PUFSD- 751 RPL. See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. B224B1: Isolator base for low-profile detectors. See DN-60054. B21OLP: Low-profile base. Standard U.S. style. Replaces B71OLP. See DN-60054. B501: European-style, 4° (10.16 cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. FMM-1: FlashScan monitor module. See DN-6 720. FDIvI-1: FlashScan dual monitor module. See DN-6 720. FZM-1: FlashScan two-wire detector monitor module. See DN- 6720. FMM-1 01: FlashScan miniature monitor module. See DN-6720. FCM-1: FlashScan NAC control module. See DN-6 724. FCM-1-REL: FlashScan releasing control module. See DN- 60390. FRM-1: FlashScan relay module. See DN-6 724. FDRM-1: FlashScan dual monitor/dual relay module. See DN- 60709. NBG-12LX: Manual pull station, addressable. See DN-6 726. ISO-X: Isolator module. See DN-2243. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module; connects intelli- gent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See ON- 6926. XP10-M: FlashScan ten-input monitor module. See DN-6923. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. For a full list of required and optional equipment, see DN-60688. BB-UZC: Backbox for housing the UZC-256. Required for NFS- 320 applications. Black. For red, order BB-UZC-R. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBR: Same as above, but red. SEISKIT-3201B26: Seismic mounting kit. Required for seismic- certified applications with NFS-320 and BB-26. Includes battery bracket for two 26 AH batteries. SEISKIT-BB25: Seismic mounting kit for the BB-25. Includes battery bracket for two 26 AH batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. SEISKIT-PS/2/4: Seismic mounting kit for the FCPS-2456/58 and CAB-PSi. Includes battery bracket for two 7 AH or 12 AH batteries. OTHER OPTIONS 411: Slave Digital Alarm Communicator. See DN-6619. 411UDAC: Digital Alarm Communicator. See DN-6746. iPDACT-2/2UD, IPDACT Internet Monitoring Module: Con- nects to primary and secondary DACT telephone output ports for internet communications over customer-provided ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IR See DN-60408. iPSPLT: Y-adaptor option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red. For Black order IPENC-B. IPGSM-DP: Internet and Digital Cellular Fire Alarm Communi- cator. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. Replaces IPGSM-COM. See DH-60695. NFS-320-RB: Replacement CPU. NOTE: Keypad must be removed before shipping old unit out for repair. NFS-320-RBE: Replacement CPU, Export. NFS-320-RBC-FR: Replacement CPU, Canadian French. NFS-320-RB-PO: Replacement CPU, Portuguese. NFS-320-RB-POE: Replacement CPU, Export, Portu- guese. NFS-320-RB-SP: Replacement CPU, Spanish. NFS-320-RB-SPE: Replacement CPU, Export, Spanish. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document DN-71 12:H • 08/09/2012 - Page 5 of 6 I 1 [I I SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits . 1 Intelligent detectors .........................................................159 Addressable monitor/control modules ..............................159 Programmable internal hardware and output circuits ..........4 Programmable software zones...........................................99 Special programming zones...............................................14 LCD annunciators per NFS-320/-320E .............................32 ACS annunciators per NFS-320/-320E .......................32 addresses x 64 points Specifications Primary input power - NFS-320: 120 VAC, 50/60 Hz, 5.0 A. - NFS-320E: 220/240 VAC, 50/60 Hz, 2.5 A. Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 A of available power. This is shared by all internal circuits. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0- 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 270C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic NFS-320 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL Listed: S635. ULC Listed: S635 (NFS-320C only, excludes IPDACT). FM Approved. CSFM: 7165-0028:0243. MEA: 128-07-E. FDNY: COA#6085. City of Chicago. When used with the CAB-BM marine system, appropriate seis- mic bracket, and marine approved devices, these ONYX fire alarm control panels are approved by the following agencies: US Coast Guard: 161.002/50/0 (Standard 46 CFR). Lloyd's Register: 11/600013 (ENV 3 category). American Bureau of Shipping. NOTE: For additional information on UL- and ULC-listed model NFS-320C, see DN-60085. For information on NFS-320SYS, see DN-60637. For information on the CAB-BM marine system, see DN-60688. Standards The NFS-320 complies with the following UL Standards and NFPA 72, IBC, and CBC Fire Alarm Systems requirements: UL 864 (Fire). UL 1076 (Burglary). LOCAL (Automatic, Manual, Waterflow and Sprinkler Super- visory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). Not applicable for FM. CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires UDACT). EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- work). IBC 2000, IBC 2003, IBC 2006, IBC2009 (Seismic). CBC 2007 (Seismic). NOTI.FIRE.NEP", InteIIiOuadTh1, and ONYX WorksTh are trademarks: and Acclimate® PIusTM, FlashScan®, NOTIFIER®, ONYX®, VeriFire®, and VIEW® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. IBM® is a registered trademark of IBM Corporation. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Standard notification circuits (4): 1.5 A each. I . Resettable regulated 24V power: 1.25 A. Two non-resettable regulated 24V power outputs: -1.25 A. I - 0.50 A. Non-resettable 5V power: 0.15 A. Battery charger range: 18 AH - 200 AH. Use separate cabi- net for batteries over 26 AH. I . Float rate: 27.6 V. Cabinet Specifications NFS-320 cabinet dimensions: I . Backbox: 18.12 in. (46.025 cm) width; 18.12 in. (46.025 cm) height; 5.81 in. (14.76 cm) depth. Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) height; 0.75 in. (1.905 cm) depth. I . Trim ring: Molding width is 0.905 in. (2.299 cm). Shipping weight (without batteries): 36.15 lb. (16.4 kg). This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 933=1=1 U .1 We cannot cover all specific applications or anticipate all requirements. IFlNI a 1111111111119AMIUNG All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 6 of 6- DN-7112:H • 08/09/2012 Made in the U.S. A. A.2 Calculating the System Current Draws Calculation Column I Calculation Column 2 Calculation Column 3 Category Primary, Non-Fire Alarm Primary, Fire Alarm Secondary, Non-Fire Alarm Current (amps) Current (amps) Current (amps) Qty X [current draw]= Total Qty X [current draw]= Total Qty X [current draw] Total 1 # NACs in use (0, 1,2,3 0r4) 1 1 X 0.50J = x [0.035] KAPS-24/E n/a n/a KDM-R2 (Backlight on) ( ] a [0.100]= SLC loopt: I with jumper JP2 Cut on CPU x [0.200) or without jumper JP2 Cut on CPU x [0.400]= NCA, NCA-2 Back-light ON [ ] x [0.4001= NCA, NCA-2 Back-light OFF [ 3 x [0.200]= NCM-W, NCM-F [ ] x 10.1101= TM-4 ( ) x [0.110)= DPI-232 (Refer to manual**) ( I x[ APS-6R ACPS-2406 ACM-24A1 1 1 x [0.016F- ACM-48A [ [ x [0.016]= AEM-24AT 1 1 x [0.002]= AEM-48A 1 1 x [0.002]= Maximum number of LEDs illuminated on [ [ x (0.0054) these annunciators during non-fire Conditions: AFM-16AT, AFM-32A () 5 [0.0401= ACM-16AT, ACM-32A 3 x [0.040]= AEM-16AT, AEM-32A [ ) a [0.002]= AFM-16A - s [0.0251= ACM-8R (refer to manual**) x [ LDM (refer to manual**) I I x[ FDU-80 x 10.06431= 1 x (0.00941= 1 x(0.017] RPT-485W, RPT-485WF UDACT Communicator I ] x [0.040]= NFV-25/50 (see manual**) ( [ x( ) Four-Wire Smoke Detectors1 x( 1= x[ 1= Power Supervision Relay 1 5 [0.020]= EOLR-1 or A77-716B Notification Appliance powered from Main Power Supply DHX-501, FSD-751RP, FSD-751RPL I 3 x[ (Duct Detectors with internal relays) I 3 a] 1= Refer to installation document CHG-120 Battery Charger Local Energy Municipal Box Compatible Devices not listed above x( 1= F 1 x I- 11 x tu.oui = x [0.035] n/a We x[0.100[ x [0.200]= x [0.400]= 1 - [ x [0.400]= [ [ x [0.200[= I I x[0.110[ x[0.175[ x[ - I I x [0.070]= I 3 x [0.070]= 1 1 x [0.056]= 5 [0.056]= x [0.0563= x [0.056]= x [0.018]= x [0.065]= x[ ] x[ [S x (0.06431= x [0.090[= x [0.017[= I x[0.100]= 1 x[ 3 x[ 1= I 3 xl 3= 3 x [0.020]= I II xl ) ( ] xl x[ x[ 1= x[ [S 1= F F x F= 5 fU.LSUJ = 1 a [0.035] a (0.040) I x[0.100] x [0.2003= x [0.400]= 1 x[0.400)s [0.200]= 1 5[0.110]= I s(0.110]= x( [S 3 x [0.025[= I x [0.0013]= 510.0161= 3 x [0.016]= 3 5 [0.002]= I x [0.002[ - F x 10.00541- x [O.040] 1 3 x[0.040[= 1 1 5 [0.002]= I 510.0253= s( 1= 5 (0.06431= 1 5 [0.0094]= x[O.017)S I I 5 [0.040]= I x[ x[ 1= x[ 1= 1 5 [0.0201= x[ [S I x[ 1= I x[0.060)= I x[ 1= xl 1= Table A. 2 System Draw Current Calculations Maximum current draw for all NACs plus DC output from TB1 0 is 3.0 A during standby. t Value represents an SLC's maximum current draw. Refer to device datasheets for individual current draws. If jumper JP2 is cut, total device current cannot exceed 200 mA; if jumper JP2 is not cut, total device current cannot exceed 400 mA. The total regulated load current supplied to four-wire smoke detector and power supervision relays cannot exceed 1.25 A. Enter the total notification appliance draw from the Main Power Supply, excluding the current from APS-6R supplies. Refer to Device Compatibility Document. tt Refer to manual and/or Device Compatibility Document. See Table 1. 1, "Reference Documentation," on page 8 for specific documentation part numbers. Supplement to the NFS-320/E/C Manual P/N 52745EXP:A 07/30/2008 9 I I dn-4867:b • D-160 'UDACT Universal Digital Alarm Communicator Transmitter NOTIFIER® by Honeywell General The Universal Digital Alarm Communicator Transmitter (UDACT) is designed for use on the Notifier NFS-320, NFS2- 640, NFS2-3030, NFS-640 and NFS-3030 Fire Alarm Control Panels and on the NCA-2 and NCA Network Control Annunci- ator. When used in conjunction with the NCA-2 network con- trol annunciators the UDACT can report the status of all control panels on NOTI.FIRE•NETTM. The UDACT transmits system status to UL listed Central Station Receivers via the public switched telephone network. NOTE: The UDACT can also be used with legacy panels. Please refer to the UDACT manual for more information. The UDACT is compact in size and may be mounted externally in a separate cabinet. EIA-485 annunciator communications bus and regulated 24-volt connections are required. The UDACT is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Ott-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT is capable of transmitting all of the zone and point sta- tus associated with each panel. When the UDACT is used with the , NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Reporting may be in the form of points or zones (refer to the UDACT manual for specific reporting parameters). The first 568 points transmitted may be programmed for a variety of types, including fire, waterflow, supervisory, etc. Remaining points transmitted are for fire alarm only. NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features Maximum of 14 point trouble messages transmitted per hour. Dual phone lines. Dual telephone line voltage detect. Surface Mount Technology. Compact in size: 6.75" x 4.25" (17.145 x 10.795 cm). Built-in programmer. Built-in 4-character red 7-segment LED display. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. - Independent zone trouble. - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Off-Normal. - 12 or 24 hour test signal. - Abnormal Test Signal per new UL requirements. - EIA-485 Communication Bus Failure. © PRAAAAYACUVC FlIld8 PH P112 E l © OFOwAR OCOUM, FAIL QeIA.48s Cl— OFF TT IE M- E Uh1EHi 0 U E)M. MCDED ll!IfflI 0 Liuuju J5 (UDACT) Annunciation of UDACT Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Troubleshoot Mode converts keypad to DTMF touchpad. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kissotf, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. Open Collector relay driver for Total Communications Fail- ure or UDACT trouble. Real-time clock. Extensive transient protection. Simple EIA-485 interface to host panel. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL Listed: S635 ULC Listed: CS100 Vol. VII MEA: 328-94-E; 317-01-E3 CSFM: 7300-0028:174; 7165-0028:214; 7165-0028:224; 7170-0228:216; 7170-0028:223; 7165-0028:243, 7170- 0028:244 INDUSTRY CANADA: 2132 6030 A FCC: 1W6-USA-20723-AL-E FM Approved Communication Formats 3+1 Standard • 4+1 Standard • 4+2 Standard . 4+1 and 4+2 Ademco Express Ademco Contact ID dn-4867:b • 03/27/09 - Page 1 of 4 I ABS-8RB for remote mounting (9.94"(25.2476cm)H x 4.63(11 .7602cm)W x 2.5"(6.35cm)D] NOTE: Ademco Contact ID must be used for independent zone reporting. Type Mode Feature Ademco Contact ID format only) Use Type Mode to identify reports to Central Station as: Fire Alarm Burglary Supervisory 24 hour Non-Burglary Pull Station High Temperature Heat Detector Low Temperature Waterf low Low Water Pressure Duct Detector Low Water Level Flame Sensor Pump Failure Smoke Zone Electrical Specifications Standby current: 40 mA. Current while communicating: 75 mA. Maximum current while communicating and with open collec- tor output activated: 100 mA. Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Ordering Information 'rUDACT Universal Digital Alarm Communicator Transmitter. 'lnludesoperating and programming instructions, and mount- ing hardware. MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). ABS-8RB: Metal enclosure for externally mounting UDACT up to 6,000 ft./1828.8 m from host FACP. 9.94 H x 4.63 W x 2.50 D (cm: 25.248 H x 11.760W x 6.350 D). UBS-1: Metal enclosure. Includes viewing window and optional relay mounting capability. R-10E: SPDT Form-C relay. Contacts rated for 10 A @ 115 VAC. Connects to open collector relay driver. R-20E: DPDT Two Form-C relays. Contacts rated for 10A @ 115 VAC. Connects to open collector relay driver. FBD-1: Ferrite bead kit. Use for remote mounting only. ROM1-IJDACT: EPROM upgrade kit. UDACT shown in UBS-1 Page 2 of 4 - dn-4867:b • 03/27/09 # Ademco Silent ff1 FBI Osborne Hoffman Radionics Sescoa SurGuard (Addresses 16 & 42) 685(1) Format Knight CS4000 CP220FB 6000/6500 3000R MLR-2 1&2 '' ' 0 4 + 1 Ademco Express X X X 1 4 + 2 Ademco Express X X X(8) X 2 3 + 1 /Standard/180012300 X X (2) X X(4) X X(5,6) X X 3 (NOT USED) 4 3 + 1 /Standard/ 1900/1400 X X (2) X(4) X X X 5 (NOT USED) 6 4 + 1 /Standard/1800/2300 X X (2) X X(4) X X(5) X X 7 1 (NOT USED) 8 4 + 1 /Standard/1900/1400 X X (2) X(4) X X X 9 (NOT USED) A 4 + 2 /Standard/190012300 X X (2) X X(4) X X(5) X X B (NOT USED) C 4 + 2 /Standard/ 1900/1400 X X (2) X(4) X X X D (NOT USED) E Ademco Contact ID X X X X F (NOT USED) With 685-8 Line Card with Rev. 4.4d software. With 9002 Line Card Rev. 9035 software or 9032 Line Card with 9326A software. Rev. 4.0 software. FBI CP220FB Rec-1 1 Line Card with Rev. 2.6 software and a memory card with Rev. 3.8 software. Model 6500 with Rev. 600 software. Model 6000 with Rev. 204 software. With Rev. B control card at Rev. 1.4 software and Rev. C line card at Rev. 1.5 software. Model 2 only. Version 1.62 software. I -- dn-4867:b • 03/27/09 - Page 3 of 4 NOTI.FIRE.NETTM is a trademark and Notifiei® is registered trademark of Honeywell International Inc. ©2006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. . We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484.7118. www.notifier.com I Page 4 of 4 - dn-4867:b • 03/27/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. i7i65-OO28:0243' Page 1 of 4 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models NFS2-640,W-320/C (R), and NFS-320SYS fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), manual, automatic, waterfowl and sprinkler supervisory services. Also suitable for releasing service, Process Management and Emergency Voice/Alarm communication System *• Model numbers may be followed by an "R" suffix representing the enclosure color being red. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ACM-8R, -16AT, -32A, -24AT, -48A; Annunciator Control Modules ACPS-610, AMPS-24; Addressable power supply/charger ADP-413, -A4, -1, -2, DP-DISP2; Dress Panel AEM-16AT, -32A, -24AT, -48A; Annunciator Expander Modules AFM-16A, -I6AT, -32A; Annunciator Fixed Modules AKS-1B; Annunciator Key Switch APS2-6R; Power supply BB-100, -200, NFS-LBB/-LBBR; Battery Boxes BGRA-SCS, BGRB-SCS; Smoke Control Station BMP-1; Blank Module BP-4, BP2-4; Battery Dress Plates CAB-3/4 Series; Enclosure CAB-RP, CAB-RPR; Cabinets CEF-SCS; Smoke Control Station CHS-4, CHS-4N, CHS-4L; Chassis CPU2-640, CPU-320SYS; CPU Board CRT-2; Display Terminal DP-1B; Blank Panel DPA-1A4/1/2, DP-DlSP2; Dress Panel DPI-232; Panel Interface DR-A4, DR-A413, DR-A4BR, DR-A4R; Door Assembly DR-AA4, DR-AA413, DR-AA4BR, DR-AA4R; Door Assembly DR-B3F; Door Assembly DR-134, DR-13413, DR-13413R, DR-B4R; Door Assembly DR-C4, DR-C413, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D413, DR-D4BR, DR-D4R; Door Assembly *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 2 of 4 EQ Series; Cabinets EQBB-B4, EQBB-C4, EQBB-D4; Backbox Assembly EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1, FCM-1 -REL; Releasing Control Module FCPS-2456, -24S8; Field Charger/Power Supply FDM-1; Dual Monitor Module FDRM-1 Multiple Module with two Relay Outputs FDU-80/-80G; Remote Annunciator Fl RSTVISION-LCD/ENC; Interactive Firefighters display/enclosure FRM-1; Relay Module FTM-1; Control Module FZM-1, FMM-1, FMM-101; Monitor Modules HS-NCM-W/-MFI-SF/-WMF/-WSF/-MSSF; High Speed Network Control Modules IPDACT-2/-2UD; IP Fire Alarm Communicator ISO-X; Isolator Module KAPS-24, CPS-24; Power Supply KDM-R2; Keyboard Display Module LCD-80, -160; Annunciators LCD-80TM; Annunciator Terminal Module LCD LCD2-80; Remote Annunciator LDM-32/-E32/-R32; Lamp Driver Module LEM-320/ELEM-320; Loop Expander Module NBG-I2LRA; Agent Releasing Abort Station NBG-12LX; Addressable Manual Pull Station NCA, NCA-2; Network Communication Annunciator NCM-W, -F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station NFS-LBB/NFS-LBBR; Battery Box/Red NFS-3205Y5; Chassis NFV-25/50, NFV-25/50ZS/ZST; Voice Evacuation Control Panels NFV-25/50DA, NFV-25/50DAZS; Distributed Audio Panels ONYXWorks-EW/-NW-/NF/-HNW/-HNM F/-HNSF/-TS/-EW-TS/-NF-TS/-HW-TS/ -HNMFT/-HNSFT/-HNWT; PC workstation for NOTI .FIRE.NET, Wire/Fiber/ with Touch screen monitors PRN-6; Printer RKS-S; Remote Security Key Switch RPT-W, -485W; Repeater Wire RPT-F; Repeater Fiber RPT -485FW; Repeater Fiber/Wire RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-M4R; Backbox Assembly SBB-134, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly I I I I *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I I I I Listing No. 7165-0028:0243 Page 3 of 4 SCE-8; Smoke Control Expander SCS-8L; Smoke Control Lamp Driver Station SCE-8L; Smoke Control Expander Lamp SCS-8; Smoke Control Station STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A4/-B3N/-B4/-C4/-D3N/-D4; Trim Ring UbACT UDACT-2 Universal DACT UZC-256; Universal Zone Coder VP-213; Dress Panel XP5-CI-M; Transponder Modules XP6-C; Supervised Control Modules XP6-MA; Six Zone Interface Modules XP6-R; Six Relay Control Modules XP10-M(A); Ten Input Monitor Modules XPM-8L; Transponder Monitor Modules The following models are intended for use on NFS2-640 only: AA-30, -100, -120; Amplifiers ACT-1, -2, -4, -25, -70; Audio Coupling Transformer ADDR-B4/-B4RI-C41-C4R/-D4/-D4R; Door Assemblies AMG-E; Audio Message Generator AVL-1; Audio Voice Link BDA-25V/-70V; Backup Digital Audio Amplifiers CHS2-M2, CA-1, CA-2; Chassis CMIC-1, CMIC-RP; Microphone Assembly DAA-50251-5070; Digital Audio Amplifiers DM-5025F/DAA-50255F; Digital Audio Amplifiers DAA-5070F/DAA-50705F; Digital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-75255F; Digital Audio Amplifiers DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAX-3525/-3570/-50251-5070; Digital Audio Amplifiers DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DVC; Digital Voice Command DVC-EM/-EMF/-EMSF; Digital Voice Command Extended Memory Module DVC-RPU; Remote Paging Unit FFT-7, -7S; Fire Fighter's Telephone FHS; Fireman's Handset FPJ; Fireman's Phone Jack RM-1, RM-1 SA; Remote Microphone *Rev. 10-29-13 gt 6: This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed os the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2017 Listing Expires June 3O,2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 4 of 4 TELH-1; Telephone Assembly XPIQ; Transponder Quad Intelligent Audio INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical ratings, and UL Label APPROVAL: Listed as fire alarm control units suitable for use in high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. *Control units may be used with Notifier's First Command NFC-50/100 emergency voice evacuation panals (CSFM # 6911-0028:0265). This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 Seconds. 2. Combined with 7170-028:244 I I i I I I *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I (BAT' Series Batteries I Sealed Lead-Acid General DN-6933:C1 • E-205 NOTIFIER® by Honeywell I BAT Series Batteries are Power Sonic brand batteries. BAT Series (or Power Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. I Features Provide secondary power for control panels. I . Sealed and maintenance-free. Overcharge protected. Easy handling with leakproof construction. Ruggedly constructed, high-impact case (ABS. polystyrene, 6933c0v.jpg I UI polypropylene, depending VII models). Ordering Information Long service life. Compact design. BAT-1250-BP: 10-unit bulk pack of BAT-1250 (12 V 5 AH) BAT-1270-BP: 5-unit bulk pack of BAT-1270 (12 V 7 AH) I Agency Listings and Approvals BAT-12120-BP: 4-unit bulk pack of BAT-12120 (12V 12 AH) The listings and approvals below apply to BAT Series Batteries. BAT-12180-BP: 2-unit bulk pack of BAT-12180 (12 V 18 AH) In some cases, certain modules may not be listed by certain BAT-12260-BP: 2-unit bulk pack of BAT-12260 (12 V 26 AH) approval agencies, or listing may be in process. Consult factory BAT-12550: single battery (12 V 55 AH) I for latest listing status. BAT-121000: single battery (12 V 100 AH) UL Recognized Components: MH20845 (Power-Sonic) Part Number Reference & Specifications Part Number Power Sonic Part Number Battery ______ Description DIMENSIONS Nominal Voltage Nominal Capacity @20hr. rate A.H. Width Depth Height Height over terminal Weight in. mm in. mm in. mm in. mm lb. kg. BAT-1250 PS-1250 12 5 sealed —4.21— 17 fl — 1.9 BAT-1270 PS-1270 12 7 sealed 595 151 256 65 31 94 3.86 98 4.8 2.18 BAT-12120 PS-12120 12 12 sealed 5.95 151 1 3.86 98 3.7 94 394 100 7.92 3.59 BAT-12180 PS-12180 12 18 sealed 7.13 181 299 76 657 167 6.57 167 12 5 BAT-12260 PS-12260 12 26 sealed 656 167 697 177 4.92 125 4.92 125 17 7.71 BAT-12550 PS-12250 12 55 sealed 904 230 654 138 82 208 8.98 1228 36 163 BAT-121000 PS-121000 12 1 100 sealed 112 305 6.6 168 8.2 208 8.98 1228 68 30.84 I I I DN-6933:C1 • 7/13/2011 - Page I of 2 I IT 100% g 80% LID 40% 20% 0% 100% 90% 0 80% 70% Of 60% 0 R 50% Co 0 40% 00/n 14.0 V 1KL'I! 8.0 V Characteristic Discharge Curies 170% Effect of Temperature on Capacity 6.5 13 6.0 12 a 5.5 11 5.0 10 Is 4.5 9 4.0 8 1 2 3 5 10 2030 60 2 3 5 10 20 30 minutes hours Discharge Time @ 20°C (68°F) ENEEMN.M. 0 MENEEMEN 20° -io° o° ion o° 30° 40° 50° 60° Temperature (Degrees C.) A Charging is NOT necessa=; is required. (41'F) Charging before use is necessary to help recover \ N full rapacity. 5- Charge may fail to restore full capacity. - 40°C 30°C 20°C (104°F) (86°F) (68°F) DO NOT let batteries reach this State. 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) at left: PS-121000 Shelf-Life and Storage u'mbilint iiii.i WIN no REE111hil .rni•iiu.P. UII1Ii!L!iIIUI ui 1.2 2.4 IÔOA 6 12 24 36481 2 4 6810 20 40 MINUTES x HOURS Discharge Time - at left: PS-121000 Discharge Characteristics Batteries display trademarks of the manufacturer. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MMIM11RINS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-6933:C1 ° 7/13/2011 DN-6040:A2 • E-191 CHG-1 20 Battery Charger NOTIFIER® by Honeywell General The CHG-120 is a state-of-the-art battery charging system designed for use with NOTIFIER Fire Alarm Control Panels (FACP5). It is designed to charge lead-acid batteries between 25 and 120 ampere-hours (AH). Features Charges sealed lead-acid batteries. Automatic float-type battery charger. Rated for batteries of 25 to 120 ampere-hours. Obtains full float voltage within 48 hours. For use on any 24-volt FACP which can handle the speci- fied batteries and can disable the local charger. AC Fail delay (central station applications) per latest NFPA requirements. Form-C Trouble contact. Dual outputs, for easy load distribution. Diagnostic LEDs: - Primary AC On - Charger Trouble. - Ground Fault. - Hi Charge. - Lo Charge. - Battery Voltage Level (3 LEDs). - Low Battery. Black or red NFS-LBB(R) battery cabinet (optional). Field-selectable input voltage, 120 VAC or 230 VAC. Charges: - 26 AH batteries within 9 hours. - 55/60 AH batteries within 20 hours. - 120 AH batteries within 38 hours. NOTE: Values per NOTIFIER testing. Construction and Operation The CHG-1 20 consists of a PC board and mounting chassis. Charging current is provided automatically when the battery voltage falls below the charger's output voltage. Applications Use the CHG-120 when batteries required for standby are rated between 25 to 120 AH. CHG.1 20 Specifications Primary AC (TB1): — 115 VAC, 60 Hz, 2 A. - 230 VAC, 50 Hz, 1 A. Form-C relay (TB3): 5 A at 30 VDC. Float charge voltage: 27.6 VDC. Maximum charging current: 4.5 A. Fuses F1-F3: 15 A. Battery sizes: 26 AH to 120 AH. Charging time (to charge two fully discharged batteries): - 25 AH = 9 hours. —55 AH/60 AH = 20 hours. —120 AH = 38 hours. Installation The CHG-1 20 has a variety of mounting options. It can be mounted in either a CAB-4 Series backbox or remotely in the NFS-LBB Battery Backbox. Install the CHG-120 within 20 feet (6.096 m) of the main FACP. When mounting in a CAB-4 Series backbox: The CHG-120 can be mounted in the main power supply position, on the lower left of the CAB-4 Series backbox. Using self-tapping screws, the CHG-120 can be mounted in the lower right position (normally, where the batteries are mounted) of the CAB-4 Series backbox. When mounting remotely in the NFS-LBB: The CHG-120 mounts in the left position of the backbox. NOTE: Only one 55 AH battery or two 26 AH batteries will mount with the charger board in the NFS-LBB. NFS-LBB Battery Box Battery Configuration: The battery .backbox can mount configurations of batteries as follows: Without CHG-120 mounted internally: - Up to two 26 AH batteries. - Up to two 55/60 AH batteries. - One 100 AH battery. With CHG-120 mounted internally: - Up to two 26 AH batteries. - One 55/60 AH battery. —One 100 AH battery. DN-6040:A2 • 10/18/2012 - Page 1 of 2 I I U I I 111 I NOTE: When 100 AH batteries are required, a NFS-LBB is required to mount each 100 AH battery. The CHG-120 can mount in either the CAB-4 Series backbox or in a third NFS-LBB in this configuration. Product Line Information CHG-120: Battery charger circuit board and mounting chassis. Includes mounting hardware and installation instructions. BAT-12260: 26 AH, 12-volt, sealed lead-acid battery. Order as bulk pack BAT-12260-13P, contains two. See data sheet DN- 6933. BAT-12550: 55 AH, 12-volt, sealed lead-acid battery. See data sheet DN-6933. BAT-121000: 100 AH, 12-volt, sealed lead-acid battery. See data sheet DN-6933. fNFS-LB:t Battery Backbox - holds up to two BAT-1 2550 55 AHtiáttIries or one BAT-121000 100 AH battery. Dimensions: Box: 24.0" (61.0 cm) wide x 14.0" (35.6 cm) high x 7.75" (19.7 cm) deep. Door: 24.125" (61.3 cm) wide x 14.25 (36.2 cm) high x (door adds 0.063" [approx. 0.16 cm] to depth), black. NFS-LBBR: Same as NFS-LBB above but painted red. Compliance with Codes and Standards The CHG-120 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems. UL 1481 Power Supplies for Fire Alarm Systems. CAN/U LC-5527-M87. Agency Listings and Approvals The listings and approvals below apply to the basic CHG-120. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S674. ULC: S635. FM: Approved. CSFM: 7315-0028:0189. MEA: 195-97-E, 345-02-E. FDNY: #6114. CHG-1 20 Features Voltage Selection Switch for 115 VAC or 230 VAC Nine LED Status operation Indicators Open Collector Trouble Daisy Chain Connections .- External Trouble Input e2 e" Form-C Relay to other devices a Two output '0 circuits to load (power supply, aux. power supply, I. amplifier, etc.) 25 AH-120 AN Battery 15A replaceable Connections provide short circuit and Optional Ammeter overload protection Connection NOTIFIER® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I ISO 9001 We try to keep our product information up-to-date and accurate. _________________ We cannot cover all specific applications or anticipate all requirements. I I MCINEMINS & MMIIIRIN9 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6040:A2 • 10/18/2012 F] I I I I SIGNALING LISTED Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1hdeep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 3h"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information / The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. A FAD ACE-Il FIRE ALARM DOCUMENTS ISO ,00i - REGISTERED NFPA COMPANY Made In U.S.A. I Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 I I I Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SPACE AGE ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector Pcnpydy Infn,matynn Mhtt,,,ttn, Required Donttn,ontatton (SIG-FUN) Cedificatlon, and App,00a1s 16.1 System InstallatIon Contractor. Tin ad. AtefloTAta *1u01,At a.stn..s,c.An..i.d.ensan.an 16.5 Aethorily HeolnU JUrAdio5Ofl r .r,a,,rar.aglsa,edlo.ra&m.,.uNtdn.nr vdedmeopa.tSmesrr..rb,,em.cacam noe,.a d. Eqwp,nent In(e,matlen rad.cAoo.oAan.iIo Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SUOO6851ire Alarm Storage Cabinet RED Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! 55U00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 DN-6935:13 • H-202 NOTIFIER® by Honeywell S1(A) in B2IOLP(A) Base - B200SR(A): 6.875" (17.46 cm) diameter. - B224R6(A): 6.2" (15.748 cm) diameter. - B224B1(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851(A), 0°C to 49°C (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 1000F). Low temperature signal for FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.54°C). FSP-851 R(A) installed in a DNR(A)/DNRW, -20°C to 70°C (-4°F to 158°F). ULJULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 ml mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (570C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300pA @ 24VDC (one commu- nication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24 VDC ("ON"). Installation FSP-851(A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation DN-6935:D • 12/08/2011 - Page 1 of 2 I (Fii_P45__~(A.) Series I Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan® I General Notifier FSP-851 (A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851 T(A). The FSP-851 R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851(A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication proto- col developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 360° viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1" (5.3 cm) high; base determines diameter. - 621 OLP(A): 6.1" (15.5 cm) diameter. - B501 (A): 4.1(10.4cm) diameter. - B200S(A): 6.875" (17.46 cm) diameter. I I 1 I I sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULListed:S1115. ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP-851TA). MEA Listed: 225-02-E. FM Approved. CSFM: 7272-0028:0206. Maryland State Fire Marshal: Permit #2122. BSMI: C1313066760036. CCCF: Certif. #2004081801000017 (FSP-851T) Certif. # 2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A" suffix indicates ULC Listed model. IFSP-851\ Low-profile intelligent photoelectric sensor. Must be 'moüntd to one of the bases listed below. FSP-851A: Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRAIDNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501 (A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases. ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low- profile. Fl 1OBP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-01 0: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851 (A) only; box of 10. WCK-200B: White detector covers for use with FSP-851 (A) only; box of 10. -Notifier@ and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended lobe used for installation purposes. I S0 9001 ___________ We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. E111111111111111 a 1111111111111IMMIIING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. I For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 012— DN-6935:D • 12/08/2011 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7272-0028:0206y Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC I LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com I DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-8517F-851 FSP851R* and FSP-851T photoelectric type smoke detectors. ModelsFSP-751T and FSP-851 T employ a 135°F supplement integral heat sensor which only assists in afire I' situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: I 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances I and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: ' Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-751T, FAPT-751, FAPT-851, FSP-851, FSP851R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity I between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Sounder Base B200S(A), B200SR(A) Sound output: measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone). - B200S, high-volume: Greater than 85 dBA minimum. - B200S, low-volume: Greater than 75 dBA minimum. - B200SR: Greater than 85 dBA minimum. FOR B224RB, B224B1: Operating voltage: 15 to 32 VDC (powered by SLC). Standby ratings: <500 pA maximum @ 24 VDC. Set time (B224RB only): short delay 55 to 90 msec; long delay 6 to 9 seconds. Reset time (B224RB only): 20 msec maximum. Relay characteristics (B224RB only): two-coil latching relay; one Form-C contact; ratings (UUCSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0A @ 30 VDC. Product Line Information INTELLIGENT BASES B501: Flangeless mounting base. B501 A: Flangeless mounting base, ULC Listed. - B501BP: Bulk pack of B501 (10). .B21OLP: Flanged mounting base. B21 OLPA: Flanged mounting base, ULC listed B21OLPBP: Bulk pack of B21OLP (10). B2005: Intelligent addressable sounder base capable of pro- ducing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and cus- tom tone. B200SA: Same as B2005 with ULC-listing. B200SR: Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. B200SRA: Same as B200SR with ULC-listing DN-60054:E i Intelligent Bases NOTI Fl ER® B501 (A), 13200S(A), B200SR(A), (a 130L121A), B2241B1(A), B224RB(A), by Honeywell I Mounting Kits, and Accessories General I Intelligent FlashScan® and CLIP mounting bases and kits pro- vide a variety of ways to install NOTIFIER detectors in any application. Intelligent detectors can be mounted in either flanged or flangeless bases depending on junction box selec- tion (see Junction Box Selection Guide). Across this product - line, detectors plug in easily to the base with SEMS screws; Flangeless Mounting Base Flanged Mounting Base and models employ various 12 to 24 AWG wire ranges. B501(A) B2iOLP() Relay, isolator, and sounder bases can be used to meet I local code requirements. Relay bases provide one Form-C contact relay for control of auxiliary functions such as door clo- sure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore I when the fault is removed. Sounder bases are available in temporal and non-temporal pattern versions depending on whether the signal is to be used for evacuation purposes. I Specifications Diameter: - B501: 4.1' (104 mm). - B224Bl, B224RB, B21OLP: 6.1" (155 mm). 1 - B2005/SR: 6.875 (17.46 cm). Wire gauge: - B224B1, B224RB: 14 to 24 AWG. I —B21OLP, B501, B200S/SR: 12to24 AWG. Temperature range: —B224B1, B224RB, B200S/SR: 32°F to 120°F (0°C to 49°C). I - B210LP, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F I to 1200F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the sys- tem's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room I temperature of 15°C to 27°C (60°F to 800F). Electrical Ratings FOR B200S/SR: I External supply voltage: 16 to 33 VDC (VFWR) Standby current: 500 pA maximum. Alarm current: I - B200S: 25 mA maximum at high-volume setting; 15 mA maximum at low-volume setting. - B200SR: 35 mA maximum. SLC operating voltage: 15 to 32 VDC. I SLC standby current: 300 pA. I DN-60054:E • 7/22/2011 - Page 1 of 2 I B224RB: Relay base. B224RBA: Relay base, ULC Listed. 6224B1: Isolator base. 8224B1A: Isolator base, ULC Listed. MOUNTING KITS AND ACCESSORIES SMB600: Surface mounting kit, flanged. F1 10: Retrofit flange for converting high-profile bases to low- profile. Fl lOBP: Bulk pack of Fl 10 (10). F210: Accessory flange ring for B21OLP(A) base (new design). 6-inch diameter. F21 01313: Bulk pack of F210 (10). RAlOOZ: Remote LED annunciator. RAlOOZA: Remote LED annunciator, ULC Listed. M02-04-00: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR213: Detector removal tool for current heads (T55-127-010 included). XR2: Detector Remove Tool for use with low profile detector heads, and FSL-751. XP-4: Extension pole for XR2IB (5 to 15 ft/I .524 to 4.572 m). T55-127-010: Detector removal head. BCK-200B: Black detector kit, package of 10 (for use with photo and ion detectors). WCK-200B: White detector kit, package of 10 (for use with photo and ion detectors). Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: 5911 ULC Listed: 5911 FM Approved MEA: 22-95-E, 205-94-E Vol. 2; 257-06-E CSFM: 7300-1653:0126, 7135-1653:0213, 7300-0028:0173, 7300-1653:0109 Junction Box Selection Guide Base Models Single Gang 3.5 Oct. 4.0" Oct. 4.0 Sq. 4.0 Sq. with 3.0 mud ring 50 mm 60 mm 70 mm 75 mm B200S, B200SR Yes Yes Yes Yes Yes No No No No B501 No Yes No No Yes Yes Yes Yes No B21OLP \ Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Li I I I FlashScan®, NOTIFIER® and System Sensor® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use 1111 of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. I b I U We cannot cover all specific applications or anticipate all requirements. QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. I www.notifier.com Page 2 of 2— DN-60054:E • 7/22/2011 I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. ,,7300-1653_0109 , Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyev@honeywell.com DESIGN: Models 8401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, 134048, 1340413T, 1340613, B501, B50113, 14506587-002, 1350113H, B501BHT, 1340113H, 13110LP, 13110RLP, B11ORLP750, B1I2LP, 13II4LP, 13114LPBT, 131 16L andB210Letector bases. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 I I 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I 1 I I DN-6726:D • H-240 NBG-1 2LX Addressable Manual Pull Station General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSF- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/o) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on CLIP protocol loops. Up to 159 NBG-1 2LX stations per loop on FlashScan® pro- tocol loops. Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location NOTIFIER® by Honeywell The NBG-12LX Addressable MiiiiaI Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4° (10.16 cm) square electrical outlet box, or will surface mount to the model SB-i 0 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 40 (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 on FlashScan® systems, 1 —99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or [I I I I DN-6726:D.4/13/2012—Page 1 of 2 Li 4 '110, 16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. I The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information I , '4NBG-12LX:lDual-action addressable pull station. Includes key locking fetre. (Listed for Canadian and non-Canadian appli- cations.) I NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. I SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. I NY -Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be I listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S692 (listed for Canadian and non-Cana- than applications). MEA: 67-02-E. CSFM: 7150-0028:0199. FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). I . BSMI: C1313066760047. U.S. Coast Guard. Lloyd's Register. I . FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; I 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENSINEM11111 & M(UFIC1UIUNB All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-6726:O • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150028 0199 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-12-LO,_NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-I2WP, NBG-12LWP, NBG-1 2L,QjBG-12LX NBG-1 2LA, NBG-1 2PS, NBG-1 2LSP, NBG-12LPS, NBG-12LPSP, NBG-12SP, NOT-BG2LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-I2LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12L0, NBG-12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh e This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I DN-6720:C • H-220 I I MM-1(A)9 F,MM-101(A)9 FZM4 (A) (A) Monitor Monitor Modules with FlashScan® General Four different monitor modules are available for Notifiers intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1(A)). [FMMT(A) is a standard-sized module (typically mounts to a 4" "[10.16 cm] square box) that supervises either a Style D (Class or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-1 01(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style ..D (Class A) or Style B (Class B) circuit. (FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MM-1(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 (A) can be used to replace MMX-1 (A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class NOTIFIER® by Honeywell jJ:i > I cTc 2I kFMM.1(A) (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:C • 10/06/2010 - Page 1 of 4 I I FMM401(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. 1415 0 1 ADDRESS 0 1 LOOP 1O 5I 8 76 8 76 TENS ONES The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Page 2 of 4— DN-6720:C • 10/06/2010 Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65' (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops, 01 —99 on CLIP loops. LED flashes during normal operation; this is a programma- ble option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2125° (5.398 cm) deep box. I I I I I III1 oi I wI Ic l Illu 0J I Hu co FDM11A) Dual Monitor Module I The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire I alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-l(A) provides two Style B (Class B) IOC circuits I ONLY Style D (Class A) IOC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS I Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). I Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA I EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). I Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5° (11.43 cm) high x 4' (10.16 cm) wide x 2.125° (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING I The FDM-1 (A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses '26" and "27". I NOTE: "Ones" addresses on the FDM- 1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. I A CAUTION: Avoid duplicating addresses on the system Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4° (10.16 cm) square, 2.125° (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:0219 MEA: 457-99-E U.S. Coast Guard: I I I I I I I I - 161.002/23/3 (AFP-200: FMM- 11-101, FZM- 1) - 161.002/42/1 (NFS-640: FMM- 11-101) Lloyd's Register: —03/60011/El (FMM-1I-101, FZM-1) - 94/60004/E2 (AFP-200: except FDM- 1) - 02/60007 (NFS -640: FDM- 1) FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information NOTE: "A" suffix indicates ULC-listed model. MM-1(A): Monitor module. FMM-1 01 A): Monitor module, miniature. Monitor module, two-wire detectors. Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51253. DN-6720:C • 10/06/2010 - Page 3 of 4 FlashScan® and NOTIFIER® are registered trademarks and FireWatchlm is a trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. d U • .1 We cannot cover all specific applications or anticipate all requirements. lF&lN &uicnmri All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. I For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 4 of 4— DN-6720:C • 10/06/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 2i9) Page 1 of I 739-008.0 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface moduleFMM-1FMM-101, FZM-1, FSM-101,M-11 FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. I NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. I J I *Rev. 10-24-11 mt I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct I V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2017 Listing Expires June 3O,2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division F E '- SYSTEM ~4 SENSOR® Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications I System Sensor L-Series audible visible notification I products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. I Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices Compatible with MDL3 sync module Listed for wall mounting only Agency Listings SIGNALING & ow A1111.1M S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057363, 3057072 The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/e-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, [-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync'Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor [-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe U shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and U[ 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MD[3 listed to U[ 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature P. 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/RNR1'2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) InputTerminal Wire Gauge 12to18AWG Wall-Mount Dimensions (including lens) 5.6" [ x 4.7'W x 1.91'S D (143 mm [ x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46" W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6"[ x 4.7"W x 1.25'D(143 mm Lx 119 mm x 32 mm 0) Compact Horn Dimensions 5.25" Lx 3.45W x 1.25" D (133mm Lx 88mm W x 32mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. U I I I I I I I U I UL Current Draw Data IuJ Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 - 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiah 42 43 54 IJuMax. Currenta DC Input :1iW.awr1i:r 8-17.5 Volts 115cd 30cd 16-33 Volts lscd I 30cd tTi 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.lKTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. I I I I 5 L-Series Dimensions 1.91 3.46 - 1.25 .I.u.I.,.s.,. 5.27 Compact Strobe / Horn Strobe 3.46 1.25 000 0, 6 0000 0 00000000 0000000000 .27 000000 5000, Compact Horn I I Horn L-Series Ordering Information Wall Horn Strobes Horns P2RL 2-Wire, Horn Strobe, Red HRL Horn, Red P2WL \ 2-Wire, Horn Strobe, White HWL Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HORL Compact Horn, Red P2GWL 2-Wire, Compact Horn Strobe, White HOWL Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box, White SRL Strobe, Red SBBGRL Compact Wall Surface Mount Back Box, Red SWL Strobe, White SBBGWL Compact Wall Surface Mount Back Box, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have ALERT' marking on cover T"s\ 5yç7fL,q 3825 Ohio Avenue • St. Charles, IL 60174 ©2017 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit SySternsenSormn .Co 1 5JI,501,e or current product information, including the latest version of this data street. www.systemsensor.com AV0S86503 • 03117 I Eli Li F: I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-16530503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyev@honeywell.com DESIGN: System Sensor Indoor 2-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL,tP2I P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP and P2WL-SP Wall Horn Strobes; PC2RL and PC2WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. [ii WailTrim Rings: TR2 and TR2W Ceilinglrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, I Ceiling Surface Mounted Back Boxes: 02-14-17 gt ø This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I [1 [1 Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20 KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division