Loading...
HomeMy WebLinkAbout2436 TOWN GARDEN RD; BLDG 15; FPC2018-0367; PermitPERh'UET REPORT I AUG - 1 Print Date: 09/27/2022 Permit No: FPC2018-0367 Job Address: 2436 TOWN GARDEN RD, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fixed Extinguishing Syste Parcel #: 2132601000 Track #: Applied: 11/13/2018 Valuation: $3,501,830.92 Lot #: Issued: Occupancy Group: Project U: Finaled Close Out: 04/14/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check U: INSPECTOR: Wong, Cindy Plan Check U: Project Title: Description: VIASAT BLDG 15 -CLEAN AGENT/PRE-ACTION SYSTEM FOR 1ST FLR MDF ROOM & 2ND FLR IDF ROOM Applicant: FPContractor: FACILITIES PROTECTION SYSTEMS INTELLIGENT TECHNOLOGIES AND SERVICES FRANK KUNOWSKI INC 1150W CENTRAL AVE, USTE D 115OW CENTRAL AVE, U D BREA, CA 92821-2257 BREA, CA 92821-2259 (714) 257-2244 (714) 257-2244 FEE AMOUNT FIRE Special Extinguishing System $586.00 Total Fees: $586.00 Total Payments To Date: $586.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov HFC-227ea CLEAN AGENT / PRE-ACTION DETECTION & CONTROL SYSTEM ENGINEERING SUBMITTAL FOR VIASAT 2436 TOWN GARDEN ROAD CARLSBAD, CA PROVIDED BY: FPS Specialists in Fire Systems 1150 W. Central Ave Suite 0, Brea, CA 92821 T: 714-257-2244 www.fpsys.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0900:0149 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Fike Protection Systems704 South 10th St., Blue Springs, MO 64024 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Model Cheetah Xi 10-068-c-p(-L) (C: R = Red or G = Grey; p: 1 = 120V or 2 = 240V; L: L = Lexan or Blank = No Lexan) and Model Cheetah Xi 50 Part no. 10-071-c-p(-d) (c: R = Red or G = Grey; P: 1 = 120V or 2 = 240V; d: d = Dead Front, Blank = no Dead front) Fire Suppression Control Units. Base configuration includes the main board, enclosure and a transformer. Local, auxiliary, remote, central station service and releasing service. Also suitable for proprietary PPU and proprietary receiving station when used with Model 10-2627 or 10-074. Models 1016, 254 and 50 are suitable for critical process management and voice evacuation via Fike Guard model FGX-MP/DP. Refer to listees data sheet for detailed product description and operational considerations. System components: 10-2542; Cheetah Xi Controllers 10-2622; 50 Point Controller 10-2473; Supplemental Loop Module 10-2474; Supplemental Power Supply 10-2204; CRM4 Relay Module 10-2254; Reverse Polarity Module 10-1832; Agent Releasing Module Ill 10-2482; Network Card FGX-MPIDP; Voice Evacuation System 24-001 thru 24-012; Master Panel Voice Evacuation System 24-013 thru 24-024; Distribution Panel Voice Evacuation System 10-2541-C; Cheetah Xi Enclosure 10-2541-C-L; Cheetah Xi Enclosure with Lexan 10-2623-C; Cheetah Xi 50 Enclosure 10-2476; DACT -I 10-2528; DACT 10-2321; Remote Display 10-11 x; LED Display Graphic 10-2413; Masterbox Supervision Module 10-2361; Series Impedence *Revision 02-24-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0900:0149 Page 2 of 2 10-2373; Zone Annunciator 55-052, -053; Releasing Module 55-042; Control Module 10-2630, -2631, -2646; Remote Display 10-2583, -064; Multi-Interface Module 10-2627, -074; Ethernet Module 10-2624; Fiber Optic Network Card 10-2667; Remote 20 Zone Annunciator 10-2748; Impulse Releasing Module (IRM) *102946 70-279; Impulse Releasing Module Assembly *68.517. High Level Interface Assembly INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 1999 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Revision 02-24-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division rTCrT ! / Lr CHEETAH® XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike's Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system. It is ideal for all life safety and property protection applications, and is intended for both commercial and industrial use. It designed with extensive programmability that allows the almost instantaneous reiay or inrormation and the ability to perrorm process management tasks with ease including HVAC shutdowns, Emergency Voice Evacuation, damper control, door closure, elevator recall, security, and CCTV/Building Management Awareness. This cost-effective panel comes standard with two Signaling Line Circuits (SLC) that support 254 devices each. This is expandable to four loops and a total panel capacity of 1016 devices, with any mix and match of sensors and modules. The Cheetah Xi utilizes extreme intelligence via its Eclipse® based sensors including photoelectric, photoelectric with heat, ionization, photoelectric duct, and heat detectors. It also utilizes Eclipse based modules such as the monitor, mini-monitor, relay, intelligent pull station, releasing and control modules. With Cheetah Xi, every device communicates as a peer on the signaling line circuit. These peers not only communicate up-to-the-second information to the control panel, but also communicate with each other. Each device is capable of generating accurate and highly detailed information. Conventional suppression alarm systems give a general idea of the fire's location, while the Cheetah Xi's intelligent sensors indicate precisely which device is in an alarm state. This intelligence provides incredible speed with response times as little as one-quarter second between manual pull station and notification appliance. It's flexibility allows you to attach the intelligent devices that are required for your specific application. The System is programmed with either the Windows based field configuration software C-LINX" or through a comprehensive password protected front-panel keypad programming option. This option allows you to quickly update and adapt to any future requirements or changes in the system such as changes in occupancy or remodeling. The sophisticated control panel circuitry coupled with the software allows you to read specific information and sensitivity levels of the different eclipse devices. The sensors also compensate for any changes due to age, contamination, or other environmental factors. SYSTEM OPERATION The Cheetah Xi Control system operates on a "Zone and State" relationship. In this design, all input and output devices must be assigned to at least one zone (253 are available), each zone defining an area to be protected. Input devices can be assigned up to four zones (one zone is typical) and output devices may be assigned up to 254 zones. These devices use the SLC signaling line circuits to exchange status information with other devices as well as with the control panel. When an input is activated, it is configured to cause its associated zone to enter into an operational state. Any detection device will cause the associated zone to enter into an alarm state. The output devices are configured to activate to protect and evaluate the endangered zone. This system is completely modular, allowing you the flexibility to design a system that is just right for your application. A typical configuration is shown on page 2 that illustrates the communications of a Cheetah Xi system. Fike Cheetah Xi APPROVALS: UL Listed - S2203 FM Approved - 3023436 CSFM - 7165-0900:149 City of New York - 307-05-E City of Denver State of CA Seismic - OSP-007-10 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.fike.com TYPICAL CONFIGURATION c-- --------- 4 - - cp,nkk:t*.41 o 3ouo. Syitons 1 Refe r,aj Mode VOSDAa 0: 5 0 - ast Fix 5e,At bee D-oi Sapi V ,mS, and 5p, a(,Inn cLOt Pheto 1pe PCate Heat Lete, c-vi PeEL 'aLO, F i - Ej, Snaba tC Module RIay Maaaiute End ad Une R. ELontor Module Twa ua Pe4o,ma Pananna Mattaguntaut ma-Se a-ta-ben 1--, cite SLuutawaa V*;_Laaiiva-!*n mn At .- i HVPC FttCTV, L.eaaias Ma,tcn,.,e,e Ae--n ainienet ,, Fiat •0tia Detain,, STANDARD FEATURES The Cheetah Xi features are designed to save lives and protect your valuable capital investments through unprecedented speed, intelligence and flexibility. These features include: All Cheetah Xi panels come standard with a controller, transformer and enclosure (see ordering information for details) 254 user defined zones 80 character, backlit LCD display Real time clock 3200 event history buffer Critical process monitoring One-person walktest capability Disable by zone, device or circuit Drill function at panel and remote Provides solenoid releasing operation Alarm verification Easy to add/remove devices Diagnostic menus Removable terminal blocks for field wiring Local piezo with distinct event tones 10 Status LEDs to easily identify system status Optional point iD DACT Module available Supports up to 31 peripheral devices such as Remote Display, LED Graphic, Multi-Interface Module, Ethernet Module and Zone Annunciators 2of6 CHEETAH XI CONTROLLER SPECIFICATIONS The controller contains the power supply, microprocessor, hardware interface, display and keypad. Enclosure Steel Enclosure 23.6" H x 14.35" W x 4" D (Back-box dimensions) Flush or surface mounting Removable door for ease of installation Two door options available; with or without lexan cover on oval opening Available in red or grey Dead Front option available to isolate panel's internal electronics and wiring Power 6 amps useable alarm power, expandable to 12 amps (2 A standby/expandable to 4) Operation from 120VAC/60 Hz or 240 VAC 50/60 Hz transformer Two 24V DC, 2A continuous auxiliary power outputs (Expandable to 5 circuits with SPS) One 24VDC, 2A resettable auxiliary power output Supports up to 75AH of batteries, expandable to 150 AH using SPS Controller consumes 0.275A @ 24VDC in normal and alarm mode Signaling Line Circuit Address devices with Infrared (IR) tool, similar to remote control device Two SLC loops, expandable to four, NFPA style 4, 6 or 7 254 devices per loop, system maximum 1016 devices with SLM (Supplemental Loop Module) True peer-to-peer digital protocol for extremely fast and reliable communications Auto-learn function Automatic day/night sensitivity adjustment Automatic holiday sensitivity adjustment Acclimate operation for sensors IR Tool provides ability to read sensitivity levels or perform remote test of device Devices contain multi-color LED for quick reference of device status Sensors provide early warning pre-alarm detection and can also provide a summing feature. (up to eight sensors) Maximum Resistance: 70 ohms Maximum Capacitance: .60 uf 12,000 ft. maximum distance total from panel to last device. NAC Circuit Two NAC circuits standard Rated at 24VDC, 2.0 Amps maximum Built-in synch protocol for both System Sensor® and Gentex® devices OPTIONAL MODULES AND PERIPHERALS Supplemental Power Supply (SPS) (P/N 102474P)* The 10-2474-p includes the power supply circuit board and transformer (-1 for 120VAC primary; -2 for 240VAC primary). This module adds up to 2.OA external standby power and 6.OA alarm power (4 A standby/12A alarm total). AC power and standby batteries are supervised. Supports charging up to 75Ah of additional standby battery. Charging may be turned off in configuration if batteries are not required on SPS. Control Board dimensions: 4-1/2" Lx 5-1/2" H x 2" D. Weight: 0.66 lbs. Transformer dimensions: 5" Lx 3-3/4" H x 3-1/2" D. Weight: 7 lbs. Supplemental Loop Module (SLM), (P/N 102473)* The SLM adds two more SLC loops. Loop specifications and wiring for SLM are the same as the main controller. It interfaces to the main Control Panel using four standoffs supplied with the SLM. Dimensions: 2" Lx 6-1/2" H x 1"D. Weight: 0.12lbs. Point ID Dact (Digital Alarm Communicator Transmitter) Module (P/N 102528)* The DACT provides interface with Central Station monitoring systems. It is available with 5 contact zones of connection OR the intelligent serial interface which provides point ID information. The Contact ID form is the preferred reporting format. It provides a four digit account code followed by a three digit event code, a two-digit group number, and a three digit contact number, all of which are used to provide specific point identification. This DACT can also provide an SIA or 4/2 Pulse reporting format. Note: 10-2476 is the same as 10-2528 with enclosure for external mounting. Dimensions: 6-1/2" Lx 4" H x 1" D. Weight 0.32 lbs. Fike Relay Module (P/N 102204)* The CRM4 provides 4 additional independently programmed relays. Cheetah Xi Control Panel supports up to 2 CRM4 modules (if either options are not unused) on the main controller board. Each relay may be wired across normally open or normally closed contacts. Dimensions: 3-1/2" Lx 1-1/2" H x 2" D. Weight: 0.10 lbs. Fike Reverse Polarity Module (CRPM) (P/N 102254)* The reverse polarity module provides the ability for UL Remote Station supervision. This supervision is typically performed with a direct, leased line connection. It interfaces to the main control board using four standoffs supplied with the RPM. Dimensions: 3-1/2" Lx 1-1/2" H x 2" D. Weight: 0.08 lbs. 14 Button Remote Display Unit ( P/N 102646)* The Fike fourteen button remote display (FRO), provides remote annunciation of Fike's intelligent control panels. The FRO is provided with a 80 character, backlit display which performs two display functions. First, it duplicates information provided by the control panel. Additionally the FRO has the capability of viewing system conditions such as alarm, trouble, supervisory, etc. The FRD also includes six buttons (Enter, Escape, +/-, left/right arrow) that are used for navigation through events as well as configuration of the device. Additionally it has eight programmable buttons that can be configured for things such as reset, silence, acknowledge, drill, or process. key lock is included for additional security access. Dimensions: 9-1/2" Lx 4" H x 2-1/4" D. Weight: 0.5 lbs. "See ordering information for individual data sheet that gives additional specifications 3 of 6 10 Button Remote Display Unit (P/N 102631)* The Fike ten button remote display (FRD), provides remote annunciation of Fike's intelligent control panels. The FRD is provided with a 80 character, backlit display which performs two display functions. First, it duplicates information provided by the control panel. Additionally the FRD has the capability of viewing system conditions such as alarm, trouble, supervisory, etc. The FRD also includes six buttons (Enter, Escape, +1-, left/right arrow) that are used for navigation through events as well as configuration of the device. Additionally it has four dedicated buttons that perform the following functions: drill, silence, acknowledge, and reset. A key lock is included for additional security access. Dimensions: 7-3/4" Lx 4" H x 2-1/4" D. Weight: 0.5 lbs. 2 Button Remote Display Unit (P/N 102630)* The Fike two button remote display (FRD), provides remote annunciation of Fike's intelligent control panels. The FRD is provided with an 80 character, backlit display which performs two display functions. First, it duplicates information provided on the main control panel. Additionally, the FRD has the capability of viewing system conditions such as alarm, trouble, supervisory, etc. Dimensions: 5-3/4" Lx 4" H x 1-1/2" D. Weight 0.5 lbs. Fike Zone Annunciator (P/N 102667)* The Fike twenty zone remote annunciator is used with Fike's intelligent control systems to provide remote annunciation for up to twenty zones at a location remote from the control panel. The module provides a tabular display that incorporates 20 red alarm and 20 yellow trouble/supervisory LEDs. Each LED is programmable and can provide visual indication of alarm, trouble/supervisory conditions for zones or individual points. Communication between the intelligent control panels and remote annunciator is via the RS485 peripheral bus. When an event from the control panel is received the appropriate LED will illuminate based on the annunciator's configuration. Dimensions: 4" W x 5-3/4" H. Fike Network Module (P/N 102482)* The Network Module provides the ability to network up to 128 control panels. This typically would consist of other Cheetah Xi panels. The Cheetah Xi network uses a "common zone" functionality. Zones 1-254 are common to all panels on the network and any input can be programmed to cause activation of outputs for the same zone, regardless of which panel the devices are connected to. Regardless of zone number, every state (alarm, trouble etc.) that occurs is displayed by all panels on the network. Dimensions: 4-1/2" Lx 1-1/2" H x 2" D. Weight: 10 lbs. Fike Fiber Optic Network Card (P/N 102624)* The Network Module (P/N 10-2624) provides the ability to network up to 128 control panels. This network would typically consist of other Cheetah Xi fire control panels. The network uses a "common zone" functionality. Zones 1-254 are common to all panels on the network and any input will cause activation of all outputs for the same zone, regardless of which panel the devices are connected to (except abort and predischarge on Cheetah Xi). Regardless of zone number, every state (alarm, trouble etc.) that occurs can be displayed by all panels on the network. Dimensions: 4.15" Lx 1-1/2" H x 2" D. Weight: 0.10 lbs. Fike Ethernet Module (P/N 102627)* This Module provides the ability to remote monitoring of multiple Cheetah Xi panels via Ethernet/IP. This module is connected to the Cheetah Xi via the peripheral connections at P6 and will be configured as a peripheral device. In order to utilize the remote monitoring capability, a network ID must be assigned to each panel for identification purposes. This module connects to the Panel at P6 per ± and also requires 24 volts DC from the panel to P7 24V ±. See the 06-388 Ethernet Module manual for more details. Dimensions: 8" H x 6" W x 3-1/2" D. Note: 10-074 is the same module with enclosure. Fike Multi-Interface (P/N 102583)* The primary function of the multi-interface module is that it is used as a printer interface for the Cheetah Xi control panels. It provides specific event and point information to be communicated from the panel to the printer. It is compatible with either a Epson FX-890 or equivalent IEEE 1284 standard printer or for UL required applications the Keltron 90 series UL listed fire alarm printer. Note: 10-074 is the same module with enclosure. It is also approved for the Precise Vision computer or as a gateway to existing Cheetah Classic Network. Dimensions: 8" H x 6" W x 3-1/2" D. Note: 10-069 is the some module with enclosure. PROGRAMMING CONFIGURATION Software All configuration variables can be assigned using C-LINX software. This software provides the designer the capability to provide a pre- engineered design. The user can review the construction plans to assign the zones. The configuration can also be set to identify the exact device circuit operation desired along with the custom message information. IR Configuration Tool (P/N 55051)* This optional hand-held infrared remote control is available on the Cheetah Xi system. This small device can be used in the field to simplify installation, testing and service. It operates with 2 AA batteries. It can read device information such as loop, address, branch, service dates and initiate device test. This tool: Communicates bi-directionally with any Cheetah Xi device Easily addresses devices by setting the loop and address Quickly reads sensitivity levels, date serviced, device type, loop and address, manufacture date Immediately records the date serviced Instantly initiates walk test of any sensor or module Accesses and tests hard-to-reach sensor or module (such as duct detector) through any other device on loop * See ordering information for individual data sheet that gives additional specifications 4 of 6 I I FIELD WIRING DIAGRAM PEER-TO-PEER NETWORK TO REMOTE FACP (128 NODES MAX.) TELCO LINES INTERNAL OR EXTERNAL / COMMUNICATION TO REMOTE PANELS LOCATED OFF PREMISIS TELCO LINES RS485 PER 2 PAIR SiM/ REVERSE POLARITY TO UL REMOTE STATION DETECTOR 014-BOARD RELAYS UP TO 253 PROGRAMMABLE ZONES 10-1874 CABLE CD LAPTOP PC 120/240 VAC DEDICATED POWER INPUT CHEETAH 24 EXTERNAL BATTERIES MODULE MAX) COMPATIBLE DETECTOR FIRE MM SCM IDC NACI CONTROL MAX.) 1. PANEL IS EXPANDABLE TO 4 LOOPS WITH OPTIONAL SLM 4 SLC NOTES. SOLENOID SUPPRESSION SYSTEM RELEASE (ARMISOLENOID) MM "SCMRM FIRE COMPATIBLE DETECTORS DC NAC/ CONTROL SOLENOID SUPERVISED NAG CIRCUIT El SUPERVISED NAG CIRCUIT #2 ZONE 'HERAL REMOTE LE DISPLAYS ANNUNCIATOR GHIC 24V-DC AUX POWER (RESET-TABLE) 24V-DC AUX POWER (CONTINUOUS) -H_ ETHERNET _H MULTI- MODULE INTERFACE MASTERBOX SYSTEM PRINTER MASTERBOX SUPERVISOR ORDERING INFORMATION - Fuke P/N . Description Individual Datasheet # 10-068-c-p or 10-068-c-p-L Cheetah Xi System, includes Controller, Enclosure, and Transformer c: (R=Red, G=Grey) p: (1=120V, 2= 240V) L=Lexan D.1.10.01 10-2542 Cheetah Xi System Controller (included with 10-064-c-p and —L) D.1.10.01 10-2519-c Dead Front Option C: (R=Red, G=Grey) Optional Modules 10-2474-p Supplemental Power Supply p: (1=120V, 2=240Volt) 0.1.12.01 10-2473 Supplemental Loop Module (adds 2 SLC Loops) 0.1.13.01 10-2204 CRM4 - Relay Module D.1.14.01 10-2254 CRPM - Reverse Polarity Module D.1.15.10 10-2482 Network Module D.1.17.01 10-2624 Multi-Mode Fiber Optic Network Module 0.1.21.10 Peripheral Devices 10-2630 2 Button Expanded Protocol Remote Display P.1.103.01 10-2631 10 Button Expanded Protocol Remote Display P.1.107.01 10-2646 14 Button Expanded Protocol Remote Display P.1.108.01 10-2667 Zone Annunciator P.1.118.01 10-2627 Ethernet Module D.1.22.01 10-2583 Multi-Interface Module P.1.85.01 10-2528 Point ID DACT (Internal Mounting) D.1.18.01 5 of 6 Intelligent Sensors 63-1052 Photoelectric Smoke Sensor Non-Isolator Version P.1.88.01 63-1058 Photoelectric Smoke Sensor Isolator Version P.1.88.01 63-1053 Photo/Heat Combination Sensor Non-Isolator Version P.1.89.01 63-1059 Photo/Heat Combination Sensor Isolator Version P.1.89.01 60-1039 Thermal Sensor Non-Isolator Version R1.90.01 60-1040 Thermal Sensor Isolator Version P.1.90.01 67-033 Ion Sensor Non-Isolator Version P.1.91.01 67-034 Ion Sensor Isolator Version P.1.91.01 63-1057 Duct Sensor Non-Isolator Version P.106.01 63-1062 Duct Sensor Isolator Version R106.01 63-1056 Duct Housing P.106.01 Intelligent Sensor Bases 63-1054 6" Sensor Base Non-Isolator Version R1.98.01 63-1060 6" Sensor Base Isolator Version P.1.98.01 63-1055 4" Sensor Base Non-Isolator Version P.1.99.01 63-1061 4" Sensor Base Isolator Version P.1.99.01 63-1064 Sounder Base P.101.01 63-1063 Relay Base P.101.01 Intelligent Modules 55-045 Mini-Monitor Module Non-Isolator Version P.1.93.01 55-050 Mini-Monitor Module Isolator Version P.1.93.01 55-041 4" Monitor Module Non-Isolator Version P.1.92.01 55-046 4" Monitor Module Isolator Version P.1.92.01 20-1063 Intelligent Pull Station Non-Isolator Version (Fire) P.1.65.01 20-1064 Intelligent Pull Station Isolator Version (Fire) P.1.65.01 20-1343 Intelligent Pull Station Non-Isolator Version (Agent) P.1.104.01 55-042 Supervised Control Module Non-Isolator Version P.1.94.01 55-047 Supervised Control Module Isolator Version P.1.94.01 10-2360 Series Solenoid Diode/Resistor (Needed for solenoids) 10-2413 Masterbox Interface 55-043 Relay Module Non-Isolator Version P.1.95.01 55-048 Relay Module Isolator Version P.1.95.01 55-052 Release Control Module Non-Isolator Version P.1.95.01 55-053 Release Control Module Isolator Version P.1.95.01 10-1832 ARM III Agent Release Module C.1.04.01 10-2748 Impulse Release Module (IR( lV.1.15.01 Programming Parts 55-051 Infrared (IR) Remote Control Tool P.1.97.01 06-327 C-LINX Software 10-1874A Interface Communication Cable (DB9 to RJ11) 10-18748 Interface Communication Cable (USB to Rill) 02-11139 Communication Cable Converter (USB to DB9) 10-2477 DACT Programmer Copyright © Fike Corporation All Rights Reserved. 6 of 6 Form No. D.1.10.01-3, June 2011. Specifications are subject to change without notice. I I 33 AH Battery Enclosure Installation Instructions An ISO 9001-2000 Company DESCRIPTION The battery enclosure is designed for applications where the required battery backup for the system exceeds the maximum battery size that will fit within the standard control panel enclosure. The 33 AH battery enclosure is made of 14 gauge steel with a red or gray textured enamel finish. The enclosure is designed to be surface mounted and is equipped with numerous conduit knockouts on top and sides of the enclosure to allow easy access to the cabinet interior during system installation. A solid lid is provided with each enclosure that conceals the batteries after installation. 33 AH Battery Enclosure SPECIFICATIONS Part Number: 10-2154-C, 33 AH battery enclosure C = designates color option (red or gray) Weight': 17 lbs. (7.7 kg) empty Finish: Red or gray textured enamel Capacity: Up to two 33 AH batteries Mounting: Surface mount 1Enclosure weight does not include batteries, only back box and lid. INSTALLATION Unpack the enclosure and check for shipping damage. Select the appropriate mounting location for the battery enclosure. Refer to drawing on the backside of this sheet for enclosure dimensions. Battery enclosure must be installed within 15 feet (3 m) of the control panel it is associated with. Do not install the battery enclosure in an environment that exceeds the safety limitations set by the battery manufacturer. Verify that the selected mounting surface is capable of supporting the weight of the enclosure and batteries before proceeding. It may be necessary to reinforce the mounting surface to support the weight of the enclosure and batteries. Determine the quantity and size of conduit to be attached to the enclosure and remove appropriate knockouts. Use the mounting holes located in the back of the enclosure and suitable anchors to secure the box to the mounting surface. Install batteries and connect wiring. Secure batteries in place with the mounting bracket supplied with the battery enclosure. Press studs are provided in the back of the enclosure to allow mounting bracket to be attached using supplied washer and hex-nut. Install enclosure lid using supplied mounting hardware. Fike®, 704 SW io' Street, P.O. Box 610, Blue Springs, Missouri 64013-0610 U.S.A. • Tel: (816) 229-3405 • Fax: (816) 229-4615 While every precaution has been taken during the preparation of this document to ensure the accuracy of its content, Fike assumes no responsibility for errors or omissions. Fike reserves the right to make changes to the product or this document without notice. www.fike.com P/N 06-534 Rev. 0 page 1 of 2 10.00" 2.20 ----- -)--- 2.15" [5.46cm] - I JNTING HOLE (NP. 2 PLCS.) THREADED PRESS STUD (TYP. 2 PLCS.)" FRONT VIEW (WITH LID OFF) 33 AH Battery Enclosure Dimensions TOP VIEW (WITH LID ON) .00" [53.34cm] 6.60 [42.16cm] 7.94cm] SIDE VIEW (WITH LID ON) - "HEX NUT AND LOCK WASHER - BATTERY BRACKET SECURED —TO PRESS-STUDS IN BACK OF BOX LID 2.50" [6.35cm]_j._. - 15.00 [38.10cm] CONDUIT KNOCKOUT 2.25" [5.72cm] I I (TYP. 2 PLCS. ON TOP 5.75"[1 4.61cm] AND SIDES OF BOX) '—BATTERY ENCLOSURE 33 AH Battery Enclosure Assembly Fike®, 704 SW 10' Street, P.O. Box 610, Blue Springs, Missouri 64013-0610 U.S.A. • Tel: (816) 229-3405 • Fax: (816) 229-4615 P/N 06-534 Rev. 0 page 2 of 2 www.fike.com IMPULSE VALVE OPERATOR (IVO) KIT (p/n 70-279) Item No. Part Number Description 1 02-12728 Impulse Valve Operator (IVO) 2 02-12755 DIN Connector w/ Wire Lead (5' 1g.) 3 10-2748 Impulse Releasing Module Assembly (IRM) 4 02-14263 Impulse Valve Operator Supervisor(IVOS) 5 70-286 Reset Tool 6 02-13130 Cotter Pin 7 02-2213 Security Tie 8 02-12925 Plastic Cap (Black) Temperature Range 32°F to 130°F (0°C to 54.4°C) Listings & Approvals UL/ ULC Listed & FM Approved SPECIFCATIONS - IMPULSE VALVE OPERATOR (IVO) (p/n 02-12728) Normal Supply Voltage 24 VDC Current Consumption 0 Amps (for Battery Calculation) Electrical Connection DIN Connector w/ Cable & '/" NPT for conduit connection IVO Material Stainless Steel (Body) / Brass (End Cap) SPECIFCATIONS - IMPULSE VAVLE OPERATOR SUPERVISOR (IV0S)(p/n 02-14263) Switch Normally Closed (Black) / Normally Open Contacts (White) / Common (Red) Conduit 0.25"ID SST Flexible Conduit 34.75" 1g. with 1/2" Knockout Connector Wire Leads 22 AWG, 44" 1g. 'fI / t IMPULSE VALVE OPERATOR (IVO) KIT DESCRIPTION The Impulse Valve Operator (IVO) provides means to electrically or manually activate the Fike Impulse Valve clean agent container by providing the force required to extend a piston that will open the rupture disc, allowing the agent to be released from the container. The IVO can be activated electrically via a signal from Fike control panel or manually by depressing red strike buttom. Fike Clean Agent Containers with Impulse Valve must use an Impulse Releasing Module (IRM) to supervise the agent release circuit wiring (for open and ground fault conditions) from the container to the control panel. The Impulse Valve Operator Supervisor (IVOS) is used to monitor the presence of the Impulse Valve Operator (IVO). When installed between the Impulse Valve and the IVO, this supervises the position of the actuation device; when the IVO is removed from the container this will cause a "supervisory event" at the system control panel. DATA SHEET Form No. V.1.09.01-2 704 SW 10th Street, P.O. Box 610, Blue Springs, Missouri 64013-0610 U.S.A. Phone: (816) 229-3405 • www.fike.com Impulse Valve Operator Supervisor (IVOS) INSTALLATION After the electrical / control system has been checked out and no supervisory events / ground faults are present; proceed with the actuation s ystem installation. NOTE: This should be the last items completed before the system is placed into operation. IMPORTANT NOTE: Check to ensure IVO is armed (Firing Pin retracted) and Safety Pin is place before installing to the Impulse Valve on the container. Install the wire leads from the IVOS to the control unit. (Refer to manuals 06-431 and 06-433 for wiring details) Install the wire leads from DIN connector to IRM. Install DIN connector onto IVO and secure with set screw. Remove retaining clip and plastic plug from Impulse Valve actuation port. Insert IVO into Impulse Valve actuation port and insert IVOS. The container is "NOW ARMED". Impulse Valve - Operator (IVO) 2 of 6 ELECTRIC ACTUATION - SINGLE CONTAINER SYSTEM W/ IVO For wiring installation details between Fike Control Panel, IRM and the IVO, reference the Impulse Release Module product manual (p/n 06- 552). At this point the IVO can be installed to the Clean Agent Container Impulse Valve. The Discharge Pressure Switch (p/n 02-12534) is required and is wired to the manual release contact in SHP PRO or to a monitor module in Cheetah Xi or Xi50. WARNING: Do not attempt to install the IVO with the firing pin in the extended position. —; I---- \j/ IRM Assembly Discharge Pressure Switch - . ..I -. - _______ IVO w/ Manual Strike Button ELECTRIC ACTUATION - MULTI- CONTAINER SYSTEM W/ IVO - Fike Control Panel To next IRM Assembly r---------------------------------> '4/! IRM Assembly () -- -. . IVO w/ Plastic Cap / Manual Strike Button removed (Typical for containers) IMPORTANT NOTE: When utilizing electric actuation (IRM) with multiple containers with IVO, the manual strike button on each IVO must be removed and plastic cap installed. The Discharge Pressure Switch is NOT used. This is to prevent a single container from being discharged in a multiple container system. For wiring installation details between Fike Control Panel, IRM and the IVO, reference the Impulse Release Module (IRM) Product Manual (p/n 06-552). At this point the IVO can be installed to the Clean Agent Container Impulse Valve by referring the detailed installation instructions on page 2 of this data sheet. 3 of 6 ELECTRIC & PNEUMATIC ACTUATION —TWO CONTAINER SYSTEM W/ IVO & IVPO ITEM PART NUMBER DESCRIPTION 1 02-4530 'h" NPT x %" JIC Adaptor (must be ordered separately) 2 02-4977 '4" JIC x 3.0' 1g. Actuation Hose (supplied w/ IVPO kit)(see note) 3 02-4535 1/8" NPT x '4" JIC Adaptor (supplied w/ IVPO kit) 4 02-12926 '4" JIC Male Adaptor (must be ordered separately) NOTE: This actuation method requires 2 —'4" JIC x 3.0' 1g. Actuation Hoses, 1 hose supplied w/ IVPO assembly, the 2nd Actuation Hose must be ordered separately. 1— Fike Control Panel 1T -]____ IRM Assembly Adaptor r : - - Discharge Nipple w/ —* 1 2 (see note) 4 2 3 Pressure Switch Plug - : I IVPO NOTE: Install Discharge Pressure Switch on IVO w/ Manual Strike - — _._ Container w/ IVPO Button First remove the 'A" NPT Plug from adaptor nipple, and then install actuation system as shown above. Secure actuation tubing to a solid surface. Anchoring into plaster, sheetrock wall or any other facing material is NOT acceptable. For additional information regarding the installation and resetting of the IVPO, refer to manuals 06-431 and 06-433. The Discharge Pressure Switch (p/n 02-12534) is required and is wired to the manual release contact in SHP PRO or to a monitor module in Cheetah Xi or Xi50. 4 of 6 ELECTRIC & PNEUMATIC ACTUATION - MULTI CONTAINER SYSTEM W/ IVO & IVPO ITEM PART NUMBER DESCRIPTION 1 02-4530 'A" NPT x 'A" JIC Adaptor (must be ordered separately) 2 02-4977 'A" JIC x 3.0' 1g. Actuation Hose (supplied w/ IVPO kit) (see note) 3 02-4535 1/8" NPT x ¼" JIC Adaptor (supplied w/ IVPO kit99999) 4 CO2-1359 'A" Tube Tee (must be ordered separately) 5 CO2-1356 'A" Male JIC x 'A" Male Tube Adaptor (must be ordered separately) 6 02-12695 'A" Tube x 'A" JIC Adaptor (must be ordered separately) 7 02-12696 'A" Tube Elbow-90° (must be ordered separately) 8 02-12697 ¼" Tube Coupler (not shown) (must be ordered separately) NOTE: The Actuation Hose required to connect the first container w/ IVO to the Actuation Tubing must be ordered separately. Fike Control Panel Distance will vary --I depending on 'A" x 0.035 wall Stainless container size; cut I - J IRM Assembly Steel Tubing V tubing to fit 1 2 (see note) 6 ., 4 7 £5 Adaptor Nipple w/ 'A" NPT Discharge Plug I 2 Pressure Switch 2 IVP0 IVPO 4 1 , \ lV0 - / - I / The illustration above shows the items required to make the proper connection between the container equipped w/ an IVO and the container(s) equipped w/ an IVPO. The maximum length of pneumatic actuation line (including hoses) cannot exceed 50 ft. (15.2 m) and up to 6 containers equipped w/ an IVPO. First remove the 'A" NPT Plug from Adaptor Nipple, and then install Actuation System as shown above. Secure Actuation tubing to a solid surface. Anchoring into plaster, sheetrock wall or any other facing material is NOT acceptable. The Discharge Pressure Switch (p/n 02-12534) is required and is wired to the manual release contact in SHP PRO or to a monitor module in Cheetah Xi or Xi50. For additional information regarding the installation and resetting of the IVPO, refer to manuals 06-431 and 06-433. 5 of 6 RESET INSTRUCTIONS Remove IVO from Impulse Valve by removing Retaining Clip. Remove Safety Pin and pull the red Manual Strike Button knob until p . Ivo the internal latch resets (identified by audible click) L -- I Pin Extended (IVO - Fired Position) 101 '., ,' no ii Safety Pin Insert IVO into Reset Tool and secure with Retaining Clip in Reset Tool ' '?j •0 - Retaining Clip Insert and secure the Safety Pin, push Reset Tool button (firmly) against a hard surface until IVO Pin resets (clicks into place) Reset Tool Hard Surface 110 f Retaining Clip Remove Retaining Clip and Reset Tool, IVO is reset and ready to be installed on Impulse Valve. IMPORTANT NOTE: Check IVO to ensure device is armed before inserting on Impulse Valve. ) l Safety Pin 'C I -- No Pin Exposed (IVO -Armed Position) - .- Li Copyright © Fike Corporation All Rights Reserved. 6 of 6 Form No. IV.1.09.01-2, February, 2016. Specifications are subject changes without notice. P pn DATA SHEET IMPULSE RELEASE MODULE DESCRIPTION The Impulse Releasing Module (P/N 10-2748) provides the primary interface between the supervised releasing circuit(s) of a Fike fire suppression system and the Impulse Valve Operator (IVO); which is used i. to release the fire suppressant agent from an impulse valve container. The IRM is equipped with three capacitors that receive a constant charging current from the releasing circuit of the control panel. When fully ( charged the module is capable of firing a single IVO Upon Circuit activation the output Circuit reverses its \ output voltage polarity, causing the energy in the Capacitors to be released to the Impulse Valve Operator. Each IRM is equipped with a red LED to provide positive indication that the module is in the active (release) state r - Note: The IRM is provided as part of the IVO Kit (P/N 70-279) and does not need be ordered separately if ordering the kit. SPECIFICATIONS Current Consumption: +24V Supervisory: APPROVALS 20.0 ma (during capacitor charging) 3.0 ma (after capacitor is charged) UL Listed -S3217 -24V Activated: FM Approved -37.0 ma (LED active) Cheetah® Xi Temperature: 32 to 130F (0 to 54.4CC), 93% maximum humidity Cheetah® Xi 50 Module Wiring: Control panel to IRM connections are supervised and power-limited SHP PRO® Impulse Valve Operator (IVO) connection is non-supervised and CSFM - pending power-limited MEA - pending Compatible Actuation Devices: 02-12728, Impulse Valve Operator (IVO) Compatible Releasing Panels: SHP PRO®, Cheetah® Xi, Cheetah® Xi 50 (Note: A maximum of six lAM's, wired in parallel, can be connected to each panel's releasing circuit.) INSTALLATION U1 Each Clean Agent container shall be provided with a Fike P/N 10-2748 Impulse Release Module (IRM). The APPROVED IRM shall be located at each container and shall be securely mounted in a standard 4" square x 2-1/8" deep UL Listed electrical box. Install conduit and releasing circuit wiring in accordance with the project drawings and appropriate wiring diagrams. All wiring must conform to the requirements of NFPA 70- National Electric Code, NFPA 72 - National Fire Alarm Code, NFPA 2001 - Standard on Clean Agent Fire Extinguishing Systems, and the requirements of the Local Authority Having Jurisdiction. Form No IV 1 15 01 1 704 SW 10th Street • P.O.Box 610 • Blue Springs Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.fike.com WIRING DIAGRAMS FROM RELEASING 10 1 RELEASING PANEL OR MODULE ____ CIRCUIT eweeDe 1 eaeewe 1 000000 1 7-1 + - NO - + + - NO - + IRM TERMINAL IRM TERMINAL BLOCK BLOCK CLASS B (STYLE Y) WIRING TO RELEASING (+) - PANEL OR MODULE FROM RELEASING PANEL OR MODULE eDeeoe1 =0=0=0 14- we1 0= 4. - IVO - + + - VU - + IRM TERMINAL IRM TERMINAL BLOCK BLOCK CLASS A (STYLE Z) WIRING Copyright © Fike Corporation All Rights Reserved. 2 of 2 Form NO. V.1.15.01-1, December 2010. Specifications are subject to change without notice. DATA SHEET I IMPULSE VALVE OPERATOR SUPERVISOR (IVOS) DESCRIPTION The Impulse Valve Operator Supervisor (IVOS) is used to monitor the presence of the Impulse Valve Operator (IVO) When installed between the Impulse Valve on the container and the IVO this supervises the position of the actuation device when the IVO is removed from the container this will cause a "trouble" at the system control panel. This can also be used to monitor the position of the Impulse Valve Pneumatic Operator (lVPO). SPECIFCATIONS - IMPULSE VAVLE OPERATOR SUPERVISOR (IVOS) Item Description Part Number 02-14263 Switch Normally Closed (Black) / Normally Open Contacts (White) / Common (Red) Conduit 0.25"ID SST Flexible Conduit 34.75" 1g. with 1/2" Knockout Connector Wire Leads 22 AWG, 44" 1g. Temperature Range 32°F to 130°F (0°C to 54.4°C) Listings & Approvals UL/ ULC Listed & FM Approved INSTALLATION After the electrical / control system has been checked out and no trouble / ground faults are present; proceed with the Actuation System installation. NOTE: This should be the last items completed before the system is placed into operation. IMPORTANT NOTES: Check to ensure IVO is armed (Firing Pin retracted) and Safety Pin is place before installing to the Impulse Valve on the container. Install the wire leads from the IVOS to the control unit. (Refer to typical wiring diagrams for details) Install IVO; remove Retaining Clip and Plastic Plug from Impulse Valve Actuation Port. Insert IVO into Impulse Valve Actuation Port and insert IVOS Retaining Clip. The container is "NOW ARMED". 704 SW 10th Street, P.O. Box 610, Blue Springs, Missouri 64013-0610 U.S.A. Phone: (816) 229-3405 • www.fike.com Impulse Valve Operator Supervisor ( (IVOS) Impulse Valve Actuator Port - i impulse Valve Operator (IVO) I IF Form No. C.1.79.01-1 NO TYPICAL WIRING DETAIL FOR SHP PRO TO IVOS (See SHP Pro Control Unit manual for specific wiring requirements) TERMINAL BLOCK WITH NOTCHED CLAMPING PLATE INSTALLED IN JUNCTION BOX SHP PRO PANEL SWITCH WIRE inns— IN FLEX CONDUIT NOTE: IVOS CONTACTS SHOWN TRANSFER UNDER PRESSURE RED C BLACK NC IVOS ACTUATOR SUPERVISOR NORMALLY OPEN CONTACT WIRING RED C BLACK NO PRESSURE SWITCH TYPICAL WIRING DETAIL FOR MONITOR MODULE TO IVOS (See Cheetah Xi Control Unit manual for specific wiring requirements) JUNCTION BOX TERMINAL BLOCK WITH ADDRESSABLE NOTCHED CLAMPING PLATE MONITOR MODULE INSTALLED IN JUNCTION BOX SLC OUT 1 SLC IN I R --tEOLR OR WIRING M NEXT DEVICE -- B SWITCH WIRE LEADS IN FLEX CONDUIT WHITE NO NOTE: IVOS CONTACTS SHOWN RED C TRANSFER UNDER PRESSURE BLACK NC IVOS OR PRESSURE SWITCH NORMALLY OPEN CONTACT WIRING Copyright © Fike corporation All Rights Reserved. 2 of 2 Form No. C.1.79.01-1, March, 2016. Specifications are subject changes without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRON ICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, IFX/A and IFX/D enclosures. Models ACE-1 1, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This Iistng is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VG operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SIGNALING LISTED ----------------- SRD ACE-Il ui Li) [j j E iir$ SYSTEM RECORD DOCUMENTS The SRD is the perfect item to help you meet demanding code requirements today. NFPA 72 2013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD DOCUMENTS'." The SRD is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRD has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 72 2013 7.2.1). Standard Features: Installed with a 4 GB digital flash drive with USB B connector 2 key ring hooks to hold system keys Business card holder for key contacts Overall dimensions are 12" x 13" tall and 2 1/4" deep 18 gauge steel box and cover for security Durable powder coat baked on finish other colors available Standard 3/4" cat 30 key lock. Other lock assemblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" Legend sheet for documentation, passwords and system information NFPA MEMB . ISO 9001 REGISTERED - \ COMPANY Made In\US.A. IiI1iñDTLii7 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508485.0966 Local 508485.4740 Fax Space Age Electronics, Inc. 2013 ED0584 L110641 Rev.A 1/2 No Excuses, Just Solutions! VA P,opo,ty Informaflon Minimum Required Documentation (SiG.FIJN) (RsvveFPkl21l3Ss4.71) Certifications and Approvals ,, ba 040,odroodmne* 16.1 System Instelladon Connactor. Thu.y.uso,5to0454 *650. hobsnrousndeto thtiooInmes4604,00**6ro startromaroiso*6 voravu60ov 16.5 Authydly Hauing Jurisdictoto ____ vcrooa,may.eons Equipment intormarton ,esv.410u.a,us.sros Key Ring Hooks Business Card Holder 1 C •.. 1, /rSPACE AGE —/ELECTRONICS, INC. Specifications: The system record documents box (SRD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The SRD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. .10 3 : "v- • --.J USB Storage Interface Requires Standard USB-B Connector \ 55044.ae*6uvns 40 18 ce 55055e 845ut.0*fl .0.445050,. Cr16644 Rev I Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. www.lsaecom 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Ordering Information: Part # Description SSU00689 System Record Documents Cabinet RED SSU00690 Custom screening with your Logo EA0315 10 pack door legend sheet This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0584 LT1 0641 Rev.A 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-2010:0100 Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIKE CORPORATION704 South 10th Street; P.O. Box 610, P.O.Box 610, Blue Springs, MO 64013 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Models 63-1052, 63-1058, 63-1057, 63-1062, 63-1053 and 63-1059 photoelectric smoke detectors. Models 63-1053 and 63-1059 employ a 135F fixed temperature electronic thermistor heat sensor for use only as a supplement to the smoke detector. This thermal circuitry is not approved for use in lieu of required heat detectors. Models 63-1052, -1058, -1053, -1059 are suitable for installation in a duct, velocity range 500-4000 fpm and open area protection, velocity range 0-4000 fpm. Models 63-1057 and 63-1062 are suitable for installation inside 63-1056 duct housing only. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: 1. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. 08-18-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ORDERING INFORMATION Fike P/N Mfg. Model 63-1052 63-1052 63-1058 63-1058 Description Photoelectric Smoke Detector - Non-Isolator Photoelectric Smoke Detector - Isolator Mounting Bases 63-1054 EBF 6" Flanged Mounting Base - Non-Isolator 63-1060 EBFI 6" Flanged Mounting Base - Isolator 63-1055 EB 4" Flangeless Mounting Base - Non-Isolator 63-1061 EBI 4" Flangeless Mounting Base - Isolator 63-1063 EBR Relay Base 63-1064 EBS Sounder Base Accessories 20-1085 F110 Retrofit Flange 02-3868 RA100Z Remote LED Annunciator 20-1087 XR213 Detector Removal Tool 02-4986 XP-4 Extension for 20-1087 (5-15 ft) 20-1089 BCK-200B Black Detector Kit (10 pack) 55-051 EA-CT I Tool DATA SHEET INTELLIGENT PHOTOELECTRIC DETECTOR DESCRIPTION The Intelligent Photoelectric, spot-type smoke detectors, P/N 63-1052 & 63-1058, have sensing chambers t • that utilize the light scattering principle to detect smoke. The sensing chamber employs features that minimize the effect of settled dust on performance. The detector is designed with tn-color LEDs to indicate detector status. A remote LED annunciator, P/N 02-3868, is available as an accessory. It can be configured to follow the detector LED operation or be independently controlled. The isolator version, P/N 63-1058, provides complete short circuit isolation for NFPA 72, Class X wiring if used with an isolator base. The detector is compatible with Fike's CyberCat® and Cheetah® Xi intelligent control panels. Its operating APPROVALS: parameters are configured using the panel's programming software and are stored within non-volatile RAM UL- 5911 in the detector. This on-board intelligence allows each detector to communicate its status directly to other FM devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to be MEA - 7-05-E sent between the detector and the host control panel, resulting in faster, more reliable communication. CSFM - 7272-2010:0100 SPECIFICATIONS Normal Operating voltage: is to 30 VDC Standby Current: 481iiA max. @ 24 VDC (continuous broadcasts) Alarm Current: 2 mA max. @ 24 VDC (LEDs on) FM U Humidity Range: 10% to 93% Relative Humidity, non-condensing Temperature Range: 32°F to 120°F (0°C to 49°C) APPROVED Height: 2.1 inches (51 mm) installed in 63-1054 Base Diameter: 6.1 inches (155 mm) installed in 63-1054 Base 4.1 inches (104 mm) installed in 63-1055 Base Weight: 5.2 oz. (147 g) Detector Spacing: In compliance with NFPA 72 Velocity Range: 4000 FPM (1219 m/min.) Form No. P.1.88.01-4 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.fike.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0900:0152 Page 1 of 1 CATEGORY: 7270 - HEAT DETECTOR LISTEE: Fike Protection Systems704 South 10th St., Blue Springs, MO 64024 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Models 60-1039 and 60-1040 combination electronic fixed-temperature and rate-of-rise type heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical rating: 21.6 V Fixed Temperature Rating: 135- 155°F at5Oftspacing 165-174°F atl5ftspacing 175- 190°F at50ftspacing INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/temperature rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 08-16-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DATA SHEET INTELLIGENT HEAT DETECTOR - I DESCRIPTION * The Intelligent Heat Detector, P/N 60-1039 & 60-1040, is a fixed temperature/rate-of-rise detector that can be programmed for a discrete set-point within the range of 135-170°F for ordinary detection, - or 175-190°F for intermediate detection. Detectors in the ordinary range may be programmed for either fixed temperature or 15°F rate-of-rise operation. Detectors in the ordinary range are programmed for fixed temperature only. The detector is designed with tn-color LEDs to indicate detector status. A remote LED annunciator, P/N 02-3868, is available as an accessory. It can be configured to follow the sensor LED operation or be independently controlled. The isolator version, P/N 60-1040, provides complete short circuit isolation for NFPA 72, Class X wiring if used with an isolator base. I I APPROVALS: The detector is compatible with Fike's CyberCat® and Cheetah® Xi intelligent control panels. Its operating UL -S2101 parameters are configured using the panel's programming software and are stored within non-volatile RAM FM in the detector. This on-board intelligence allows each detector to communicate its status directly to other City of New York - 63-05-E devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to CSFM - 7270-0900:0152 be sent between the detector and the host control panel, resulting in faster, more reliable communication. I I SPECIFICATIONS Normal Operating Voltage: 15 to 30 VDC F Standby Current: 451 IiA max. @ 24 VDC (continuous broadcasts); 63-1039 451 1.tA max. @ 24 VDC (continuous broadcasts); 60-1040 Alarm Current: 2 mA max. @ 24 VDC (LEDs on) APPROVED Operating Humidity Range: 10% to 93% Relative Humidity Non-condensing Installation Temperatures: -4 to 100°F (-20 to 38°C); 135 - 174°F setpoint -4 to 150°F (-20 to 66°C); 175 - 190°F setpoint Fixed Temperature Rating: 135°F (57°C) to 190°F (88°C); programmable Rate of Rise Detection: Responds to greater than 15°F/min.(8°C/min.); programmable Spacing for Thermal Detectors: Detectors set between 135 to 155oF or 175 to 1900F: Vt 50 ft (15.24 m) spacing Detectors set between 160o to 1700F: 15 ft. (4.57 M) spacing Height: 2.1 inches (51 mm)in 63-1054 base Diameter: 6.1 inches (155 mm) installed in 63-1054 base 4.1 inches (104 mm) installed in 63-1055 base Weight: 4.8 ounces (137 g) ORDERING INFORMATION Fike P/N Mfg. Model Description 60-1039 60-1039 Fixed Temperature/Rate-of-Rise Heat Detector - Non-isolator 60-1040 60-1040 Fixed Temperature/Rate-of-Rise Heat Detector - Isolator Mounting Bases 63-1054 EBF 6" Flanged Mounting Base - Non-Isolator 63-1055 EB 4" Flangeless Mounting Base - Non-Isolator 63-1060 EBFI 6" Flanged Mounting Base - Isolator 63-1061 EBI 4" Flangeless Mounting Base - Isolator 63-1063 EBR Relay Base 63-1064 EBS Sounder Base Accessories 20-1085 F110 Retrofit Flange 02-3868 RA100Z Remote LED Annunciator 20-1087 XR213 Detector Removal Tool 02-4986 XP-4 Extension for 20-1087 (5-15 ft) 20-1089 BCK-200B Black Detector Kit (10 pack) 55-051 EA-CT IRTool Form No. P.1.90.01-5 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 0 www.fike.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0900:0138 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Fike Protection Systems704 South 10th St., Blue Springs, MO 64024 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Models 63-1054, 63-1055, 63-1060, and 63-1061 detector bases. Each unit consists of resistors, capacitors, diodes, photo diodes and LED, mounted on a printed wiring board inside an enclosure which has an opening to the outside air. These devices are intended for installation on a vertical wall surface, ceiling or in a duct with a UL Listed Head. Refer to the listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible 63 Series smoke or heat detector heads and fire alarm control panels. Refer to listee's Installation Instruction Manual for details. XLF: 7300-1653:0178 *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division APPROVED Ei. PLUG-IN DETECTOR BASE SIX INCH DESCRIPTION J The Six Inch Detector Base, P/N 63-1054/63-1060, is designed for use with any of Fike's intelligent CyberCat®/Cheetah® Xi plug-in detectors. The base is approximately 2 inches (5.08 cm) larger than the detector head. The base mounts directly to a 3 1/2 inch and 4 inch octagon boxes, 4 inch square boxes (with or without plaster ring) and single gang boxes. The base provides terminals for connection of an optional remote LED annunciator, P/N 02-3868. The isolator version, P/N 63-1060, provides complete short circuit isolation for NFPA 72, Class X wiring. SPECIFICATIONS Diameter: 6.1" (155 mm); Wire Gauge: 12 to 18 AWG (0.9 to 3.25 mm') APPROVALS: UL-S911 FM City of New York - 9-05-E CSFM - 7300-0900:0138 Tfl -iThFT ORDERING INFORMATION Fike P/N I Mfg. Model Description Mounting Bases 63-1054 EBF 6" Flangeless Mounting Base - Non-isolator 63-1060 EBFI 6" Flangeless Mounting Base - Isolator Accessories 20-1085 F110 Retrofit Flange 02-3868 RA100Z Remote LED Annunciator 20-1087 XR28 Detector Removal Tool 02-4986 XP-4 Extension for 20-1087 (5-15 ft) 20-1089 BCK-2008 Black Detector Kit (10 pack) 55-051 EA-CT lR Tool Compatible Sensors 63-1052 63-1052 Photo - Non-isolator 63-1058 63-1058 Photo - Isolator 63-1053 63-1053 Photo/Heat - Non-isolator 63-1059 63-1059 Photo/Heat - Isolator 60-1039 60-1039 Heat - Non-isolator 60-1040 60-1040 Heat - Isolator 67-033 67-033 Ion - Non-Isolator 67-034 67-034 Ion - Isolator TERMINAL LAYOUT TERMINAL DEFINITIONS No. Function Ti (+) SLC in/Out 63-1054, (+) SLC in only on 63-1060 T2 No Connection 63-1054, (+) SLC out 63-1060 T3 (-) SLC in/out, (-) Remote Annunciator T4 (+) Remote Annunciator Copyright © Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.98.01-3, March 2014. This document shall not be used for installation purposes. Please refer to installation instructions applicable for each product. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0900:0143 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Fike Protection 5ystems704 South 10th St., Blue Springs, MO 64024 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Models 55-052 and *55053 Releasing Control Modules. Module is programmed to supervise either an agent release module or a solenoid. The module can only be used for one type of application at one time. The module can supervise up to six agent release modules or one solenoid, but never both simultaneously. *Model 55-053 employs on-board isolators, which can automatically assign device addresses. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Primary Operating Supply_- 24 vdc nominal, 10 mA max. current draw, power limited, supervised Addressable Loop-Style 6, Class B - 24 vdc nominal, 6 mA max. current draw, power limited, supervised INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed Fike Cheetah XI fire alarm control panel (CSFM Listing No. 7165-0900:137) for Class B operation. Refer to listee's Installation Instruction Manual for details. *Rev 03-03-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division APPROVED I11ZWL1ThFT L RELEASING CONTROL MODULE DESCRIPTION The Releasing Control Module, P/N 55-052/55-053, provides a means to supervise and control either an agent/impulse release module(s) or a solenoid compatible with the Cheetah Xi. It can only be used for one type of application at one time (either supervising up to six agent/impulse release modules or one solenoid, but never both simultaneously). This module also monitors the external power input for loss of power. The module has a tn-color LED that will flash a unique color for instant status indication (Green for normal operation, Red for module active, Yellow for device trouble). The isolator version of the module, P/N 55-053, provides complete short circuit isolation for installations requiring NFPA 72, Class X wiring. The module is compatible with Fike's Cheetah Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the module. This on-board intelligence allows each module to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol result in less information that needs to be sent between the module and the host control panel, resulting in faster, more reliable communication. APPROVALS: UL Listed -S3217 FM City of New York - 376-06-E CSFM - 7300-0900:0143 SPECIFICATIONS SLC External Supply Standby Current: Activation Current: Agent Releasing Module Solenoid Temperature Range: Humidity: Dimensions: Accessories: Mounting: ORDERING INFORMATION Normal Operating Voltage: 24 VDC Nominal Standby Current: 450 uA maximum average (continuous broadcasts) Activation Current: 6 mA (red LED on) Normal Operating Voltages: 24 VDC Nominal 6.4 mA 10 mA Supervisory Loop Voltage: 20 to 28 V Supervisory Loop Current (Normal): 13 mA Supervisory Loop Voltage: 3.3 V Supervisory Loop Current (Normal): 30 mA 32 to 120°F (0 to 49°C) 10 to 93% RH Noricondensing 4.17"H x 4.26"W x 1.22D (106 mm H x 108 mm W x 31 mm D) 2.7 kW End of Line Resistor P/N 10-2165 (included) Wall cover plate (included) Surface Mount Electrical Box P/N 20-1072 Mounts on a 4" x 4" x 2 1/8" i-Box Fike P/N Mfg. Mode Description 55-052 Releasing Module (Cheetah Xi Only) - Non-isolator 55-053 Releasing Module (Cheetah Xi Only) - Isolator Accessories 20-346 CBSOO Control Module Barrier 20-347 SMBSOO Surface Mount Box 55-051 Configuration lRTool 13-0192 COVERPLATE 10-2165 2.7K ohm End of Line Note: Refer to the Fike document P/N 06-186 for listing of compatible releasing devices that can be connected to the releasing control module. Form No. P.1.96.01-2 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 R www.fike.com Module Dimensions FO-9 1 368 2.7350 F, - Terminal Definitions Ti (+) SLC in/out T8 (+) external power line in/out T2 (-) SLC in/Out T9 (-) external power line in/out 13 (+) SLC in/Out 110 (+) external power line in/out 14 (-) SLC in/Out lii (+) ARM supervisory/(-) ARM activation T5 No Connection 112 (-} ARM supervisory/(+) ARM activation T6 No Connection 113 (-) Solenoid T7 (-) external power line in/out 114 Solenoid Copyright © Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.96.01-2, May 2014. This document shall not be used for installation purposes. Please refer to installation instructions applicable for each product. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL cmonr*Aol FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-2010:0101 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIKE CORPORATION704 South 10th Street; P.O.Box 610, P.O.Box 610, Blue Springs, MO 64013 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Models 55-042 and 55-047 Supervised Control Module; Models 55-041 and 55-046 Monitor Module; Models 55-043 and 55-048 Relay Module; 55-045 and 55-050 Mini-Monitor Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 08-18-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division APPROVALS: UL-S3705 FM City of New York - 8-05-E CSFM - 7300-2010:0101 APPROVED LTbL. JT\iThET MONITOR MODULE Clow DESCRIPTION The Monitor Module, P/N 55-041 & 55-046, provides a single, Class A or B initiating device circuit (IDC) capable of monitoring normally open contact fire alarm and supervisory devices or normally closed supervisory/process devices. In addition to monitoring the connected contacts, the module will monitor the wiring to the device for open circuits via an end of line resistor (Class B only). The module has a multi-color LED that will flash a unique color for instant status indication (Green for normal operation, Red for active input, Yellow for trouble at device). The isolator version of the module, P/N 55-046, provides complete short circuit isolation for installations requiring NFPA, Class X wiring. The module is compatible with Fike's CyberCat® and Cheetah® Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the module. This on-board intelligence allows each module to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to be sent between the module and the host control panel, resulting in faster, more reliable communication. SPECIFICATIONS Normal Operating Voltage: 15 to 30 VDC Standby Current: 485i.sA max. (continuous broadcasts) IDC Voltage: 5.4 VDC max. Alarm Current: 2.0 mA (red LED on) Maximum IDC Wiring Resistance: 100 1) Temperature Range: 32 to 120F (0 to 49CC) Humidity: 10 to 93% RH Noncondensing Dimensions: 4.17" H x 4.26" W x 1.22" 0(106 mm H x 108 mm W x 31 mm D) Accessories: 39 k() End of Line Resistor (P/N 10-2625 included) Wall cover plate (included) 20-1072 Surface Mount Electrical Box 14 kfl Short Detect Resistor, P/N 10-2530, must be ordered separately Mounting: Mounts on 4" square electrical boxes with 2 1/8" minimum depth. For surface mounting, use 20-1347 surface mount box. ORDERING INFORMATION Fike P/N Mfg. Model Description 55-041 55-041 Monitor Module - Non-isolator 55-046 55-046 Monitor Module - Isolator Accessories 20-1346 CBBSOO Control Module Barrier 20-1347 SMB500 Surface Mount Box 55-051 EA-CT IR Tool 10-2625 39 kO End of Line resistor 10-2530 14 kO Short Detect resistor 13-0192 1 C58-004-000 COVERPLATE 7045W 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 0 www.fike.com MODULE DIMENSIONS 1 2.735 H U -H 0.639 - 2.985 TERMINAL DEFINITIONS 11 (+) SLC in/Out T6 No Connection 12 (-) SLC in/Out 17 (-) IDC Class A/B 13 (+)SLCin/out 18 (+)lDC Class A/B 14 (-) SLC in/out 19 (+) IDC Class A 15 No Connection 110 (-) IDC Class A Copyright © Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.92.01-6, March 2014. This document shall not be used for installation purposes. Please refer to installation instructions applicable for each product. APPROVALS: UL-S3217 FM City of New York - 376-06-E CSFM - 7300-2010:0101 APPROVED F~, MINI MONITOR MODULE DESCRIPTION The Mini Monitor Module, P/N 55-045 & 55-050, provides a single, Class B initiating device circuit (IDC) capable of monitoring normally open contact fire alarm and supervisory devices or normally open supervisory/process devices. In addition to monitoring the connected contacts, the module will monitor the wiring to the device for open circuits via an end of line resistor (Class B only). The module has a single tri- color LED to indicate device status. The isolator version of the module, P/N 55-050, provides complete short circuit isolation for installations requiring NFPA, Class X wiring. ftP1'iThET The module is compatible with Fike's CyberCat® and Cheetah® Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the module. This on-board intelligence allows each module to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to be sent between the module and the host control panel, resulting in faster, more reliable communication. SPECIFICATIONS Normal Operating Voltage: 15 to 30 VDC Standby Current: 485 j.iA max. (continuous broadcasts) DC Voltage: 5.4 VDC max. Alarm Current: 2 mA (red LED on) Maximum lDC Wiring Resistance: 1000 Temperature Range: 32 to 120°F (0 to 49°C) Humidity: 10 to 93% RH Noncondensing Dimensions: 1.31" H x 2.73" W x 0.61" D (33 mm H x 69 mm W x 15 mm D) Wire Length: 6.5 inches (165 mm) Accessories: 39 ko End of Line Resistor P/N 10-2625 included Mounting: Inside standard electrical box behind monitored device ORDERING INFORMATION Fike P/N Mfg P/N Description 55-045 EM-1MM Mini Monitor Module - Non-isolator 55-050 EM-1MMl Mini Monitor Module - Isolator Accessories 20-1346 CB500 Control Module Barrier 20-1347 SMB500 Surface Mount Box 55-051 EA-CT I Tool 10-2625 39Kohm end of line assembly 10-2530 14K short detect resistor 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.fike.com MODULE DIMENSIONS 2.73 _7 LOOP ADDRESS 1.31 LED a a UJUJO Co WIRE COLOR DEFINITIONS Red (+)SLC in/out Red SLC in/out Black (-) SLC in Purple (+) Supervised Input Yellow (-) Supervised Input/(-) SLC out Copyright © Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.93.01-4, April 2014. This document shall not be used for installation purposes. Please refer to installation instructions applicable for each product. APPROVED Current Rating Maximum Voltage Load Description Application 2A 25 VAC PF=0.35 Non-Coded 3A 30 VDC Resistive Non-Coded 2A 30 VDC Resistive Coded 0.46A 30 VDC (L/R=20 ms) Non-Coded 0.7A 70.7 VAC PF=0.35 Non-Coded 0.9A 125 VDC Resistive Non-Coded 0.5A 125 VAC PF=0.75 Non-Coded r770.3A7 125 VAC PF=0.35 Non-Coded 7045W 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.fike.com Thi1ThFTI CONTROL MODULE DESCRIPTION The Control Module, P/N 55-042 & 55-047, provides a means to switch an external power supply to notification appliances or release solenoids used for sprinkler operation, or to activate Fike's Masterbox Interface module, P/N 10-2413, which is used on a Local Energy Type Auxiliary Fire Alarm System. The module is capable of Class A or Class B wiring. The device will monitor the wiring (while external power is not switched to the auxiliary devices) to the connected device for open and short circuits via an end of line resistor (Class B only). The module will monitor the external power input for loss of power (DC voltage supplies only). The isolator version of the module, P/N 55-047, provides complete short circuit isolation for installations requiring NFPA, Class X wiring. The module is compatible with Fike's CyberCat® and Cheetah® Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the module This on board intelligence allows each module to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to be sent between the module and the host control panel, resulting in faster, more reliable communication. SPECIFICATIONS APPROVALS: UL-52203 FM City of New York - 8-05-E CSFM - 7165-0900:0137 Normal Operating Voltage: Standby Current: Alarm Current: Maximum NAC Circuit Line Loss: Power Supply Monitor: Temperature Range: Humidity: Dimensions: Accessories: Mounting: OUTPUT RATING 15 to 30 VDC 630 uA max. average (continuous broadcasts) 2 mA (red LED on) 4VDC Regulated 24 VDC Trouble Range: 0 to 2 VDC 32 to 120F (0 to 49CC) 10 to 93% RH Non-condensing 4.675"H x 4.275"W x 1.4"D (119 mm H x 109 mm W x 36 mm D) 391<0 End of Line Resistor P/N 10-2625 (included) Wall cover plate (included) Surface Mount Electrical Box: P/N 20-1347 Control Module Barrier: P/N 20-1346 Series Solenoid Diode/Resistor: P/N 10-2360 Mounts directly on a 4-inch square electrical box with a minimum depth of 2 1/8 inches. For surface mounting, use 20-1347 surface mount box. ORDERING INFORMATION Fike P/N Description 55-042 Supervised Control Module - Non-isolator 55-047 Supervised Control Module - Isolator Accessories 20-1346 Control Module Barrier 20-1347 Surface Mount Box 55-051 IR Tool 10-2360 Series Solenoid Diode/Resistor 10-2625 39K EOL 13-0192 COVERPLATE MODULE DIMENSIONS 1 "35 I H H U i I0.639- k. 2.985 -I TERMINAL DEFINITIONS Ti (+) SLC in/out TB (+) 24 VDC External Power in/Out T2 (-) SLC in/out T9 (-) 24 VDC External Power in/out T3 (+) SLC in/out T10 24 VDC External Power in/out T4 (-) SLC in/out Til NAC (+) Class A/B T5 No Connection T12 NAC (-) Class A/B T6 No Connection T13 NAC (-) Class A T7 (-) 24 VDC External Power in/out T14 NAC (+) Class A Copyright © Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.94.01-4, March 2014. This document shall not be used for installation purposes. Please refer to installation instructions applicable for each product. / TOr DATA 5I-flEET / RELAY MODULE DESCRIPTION The Relay Module, P/N 55-043 & 55-048, provides two sets of Form "C" dry relay contacts that switch together (DPDT). These contacts can be used to initiate emergency control functions (i.e., damper closure, fan control, door holder interface, elevator recall, etc.). There is also an input that is capable of monitoring S a dry set of contacts for open or closed conditions. The module has a multi-color LED that will illuminate a unique color for instant status indication (Green for normal operation, Red for device active, and Yellow for device trouble). The isolator version of the module, P/N 55-048, provides complete short circuit isolation for installations requiring NFPA, Class X wiring. The module is compatible with Fike's CyberCat® and Cheetah® Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the module. This on-board intelligence allows each module to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to be APPROVALS: sent between the module and the host control panel, resulting in faster, more reliable communication. UL - S3217 FM SPECIFICATIONS City of New York -8-05-E Normal Operating voltage: 15 to 30 VDC CSFM - 7300-2010:0101 Standby Current: 580 lA max. average (continuous broadcasts) Alarm Current: 2 mA (red LED on) Short Circuit Current: Dry Control Input: 30 mA max. Avg. (5 VDC) Maximum Resistance: Dry Contact Input: 100W Temperature Range: 32 to 120°F (0 to 49°C) Humidity: 10 to 93% RH Noncondensing FM U Dimensions: 4.675" H x 4.275" W x 1.4" D (119 mm H x 109 mm W x 36 mm D) APPROVED Accessories: Wall cover plate (included) Surface Mount Electrical Box: P/N 20-1347 Control Module Barrier: P/N 20-1346 Mounting: Mounts on a 4" square x 2 1/8" Junction Box for flush mounting or on a surface mount box (P/N 20-1347) for surface mounting VA S RELAY CONTACT RATINGS: Current Rating Maximum Voltage Load Description Application 2A 25 VAC PF=0.35 Non-Coded 3A 30 VDC Resistive Non-coded 2A 30 VDC Resistive Coded 0.46A 30 VDC (L/R=20m5) Non-coded 0.7A 70.7 VAC PF=0.35 Non-Coded 0.9A 125 VDC Resistive Non-Coded 0.5A 125 VAC PF=0.75 Non-Coded 0.3A 125 VAC PF=0.35 Non-Coded ORDERING INFORMATION Fike P/N Mfg. Model Description 55-043 EM-1R Relay Module - Non-isolator 55-048 EM-111I Relay Module - Isolator Accessories 20-1346 CB500 Control Module Barrier 20-1347 SMB500 Surface Mount Box 55-051 EA-CT lRTool 13-0192 C58-004-000 Cover Plate MODULE DIMENSIONS 4.263 1.585 2.873 0.937 1 I TOP 0 n C] 35 4.171 c., I®!II LOOP II II ADTRE .a.ill®IIIl Fc~~ 0 4TIH0III lliiJH II 0 1,10o TERMINAL DEFINITIONS Ti (+) SLC in/out T7 Normally Closed #1 T2 (-) SLC in/out 18 Common #1 T3 (+) SLC in/out T9 Normally Open #1 T4 (-) SLC in/out T1O Normally Closed #2 TS (+) Dry Contact Input lii Common #2 16 (-) Dry Contact Input T12 Normally Open #2 Copyright © Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.95.01-5, April 2014. This document shall not be used for installation purposes. Please refer to installation instructions applicable for each product. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 6760-0900:0103 Page 1 of I CATEGORY: 6760 - ELECTRICAL SWITCHES LISTEE: Fike Protection 5ystems704 South 10th St., Blue Springs, MO 64024 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Models 10-1638 thru 10-1641, 10-1643 thru 10-1652, 20-040 and 20-046 auxiliary switches for various function (manual release, abort, main reserve, reset with or without timer assembly for releasing agent control). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as electrical switches. *Rev. 04-18-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CONTROL ACCESSORIES MANUAL RELEASE SWITCH - P/N 10-1638 The Manual Release Switch is a dual actuation device which provides a means of manually discharging the automatic fire extinguishing system when used in conjunction with the Fike Control Panel. To operate the Manual Release Switch pull the spring clip safety pin (breaking the seal) and depress the button. The switch will remain engaged until released by unlocking the button with a key. A single normally open contact block is provided. The front housing of the Release Switch is constructed of stainless steel with the keyed red plastic release button centered and bordered in black trim. The dimensions of this component are 4-1/2" wide, 4-9/16" high and 2-3/8" deep, and it may be mounted to a standard 4" electrical box or others. (Reference Data Sheet P.1.71.01). SYSTEM ABORT SWITCH - P/N 10-1639 The System Abort Switch is designed to be used in conjunction with other system equipment. It provides a temporary manual means by which the system actuation circuit may be interrupted, when operated prior to the circuit actuation. The unit employs a momentary contact push button switch. While depressed, the switch causes the agent release circuit to be manually delayed. Upon release of the Abort Switch, the release circuit will follow the specific configuration of the system control panel. The Abort Switch may be mounted to a standard 4" electrical box or others (Reference Data Sheet P.1.71.01) APPROVALS: UL Listed FM Approved CSFM Approved BSA MAIN-RESERVE SWITCH - P/N 10-1640 The "Main" to "Reserve" switch is used with systems that incorporate main and reserve (back-up) agent storage. The switch may utilize 1 or 2 Form "C" Contact blocks which will provide an electrical path to either the "Main" or "Reserve" releasing modules. Following a system discharge, reset any field devices. Once all devices are in a stand-by status the Main- Reserve Switch may be moved to the "Reserve" position. The Control Panel may then be reset to ta normal mode for uninterrupted Fike protection. The empty "main" containers can be removed for recharge. After the containers in the "Main" system have been recharged, the switch may be returned to the "Main" position. The switch may be mounted to a standard 4" electrical box or others (Reference Data Sheet P.1.71.01) KEYED ABORT SWITCH - P/N 10-1642 The System Abort Switch is designed to be used in conjunction with other system equipment. It provides a temporary manual means by which the actuation circuit may be interrupted before automatic actuation occurs The unit employs a keyed contact switch with two positions normal and abort While in the extreme left hand position the Abort Switch is in the normal mode In the extreme right hand position the release circuit is manually delayed. The Keyed Abort Switch may be mounted to a standard 4" electrical box or others (Reference Data Sheet R1.71.01). Note: Keyed abort is not recognized by approval/listing agencies. Form No. No P172011 704 SW 10th Street • P.O.Box 610 • Blue Springs Missouri 64013-0610 U.S.A. Phone: 8162293405 0 www.fike.com MAJA NçEO CR P CF <E? SWPCF-I 0 NO1MAL A ii - _A~V' 0 I, Superior E L E C T R I C MAINTENANCE BY-PASS KEY SWITCH PRODUCT DESCRIPTION: The maintenance override key switch is a disconnecting means to actuation circuits to prevent an accidental discharge when doing maintenance testing. Green LED = System Armed The key can only be removed in this position Amber LED = System Override when key switch is turned. The key cannot be removed in this position SPECIFICATIONS: Switch Rating: 5A 600VAC,IA 25OVDC LED Rating: lOmA ea. Provided with male and female insulated disconnect terminal on 24VDC Surface mounted to deep 2 gang box. Flush mounted w/ 2 gang plaster ring. Power: 24VDC APPROVALS: UL- 97152 I 340B BACK VIEW 6-POLE WIRING DIAGRAM NORMAL -24VDC RED +24VDC OVERRIDE Supervisory ckt. from control panel or addressable module. Agent release solenoid Agent release circuit from control panel or addressable releasing module 24VDC CIRCUIT BLACK •NC NO•NC •NCNC *NO CIRCUIT CIRCUIT L ... .. o AMBER --NIo N/c 2 + FORM No: 022213 1031 SERPENTINE LANE • PLEASANTON, CA 94566 • (925)484-3701 • (925) 426-5013 • www.gotoitsi.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P21R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC21R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC41R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division APPROVALS: UL -S4011 (chimes, horn strobes, horns) FM -3023572 MEA - 452-05-E CSFM - 7125-1653:186 (indoor strobes) 7125-653:188 (horn strobes, chime strobes) 7235-1653:189 (horns, chimes) SIGNALING APPROVED LISTED MEA 1-0, approved Form No P117601 TFF INDOOR SELECTABLE-OUTPUT HORNS, STROBES AND HORN STROBES FOR WALL APPLICATIONS DESCRIPTION The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field- selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. FEATURES Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting ARCHITECT/ENGINEER SPECIFICATIONS General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 1'/0-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit'" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts, Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service The horn strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances flashing at 1 Hz over the strobes entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and .án option to switch between a temporal three pattern and a non temporal (continuous) pattern These options are set by a multiple position switch. On four-wire oroducts, the strobe shall be oowered independently of the sounder. The horn on horn strobe models shall operate on a coded or non coded power supply. I 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.fike.com Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. SPECIFICATIONS Physical/Electrical Specifications Standard Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity Range: 10 to 93% non-condensing Strobe Flash Rate: 1 flash per second Nominal Voltage: Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2: 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3): 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge: 12 to 18 AWG Wall-Mount Dimensions: 5.6" Lx 4.7" W x 2.5" D (142 mm Lx 119 mm W x 64 mm D) (including lens) Horn Dimensions: 5.6" Lx 4.7" W x 1.3" D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Back Box Skirt Dimensions: 5.9" Lx 5.0" W x 2.2" D (151 mm Lx 128 mm W x 56 mm 0) (BBS-2, BBSW-2) Wall-Mount Trim Ring Dimensions: 5.7" Lx 4.8" W x 0.35" D (145 mm Lx 122 mm W x 9 m D) (sold as a S pack) (TR-HS, TRW-HS) Notes: Full Wave Rectified (FWR) voltage is o non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only loris and 15/75 Cd. UL CURRENT DRAW DATA UL Max. Strobe Current Draw (mA RMS) Candela 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA I NA 286 258 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 1 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 Cd) DC Input 8-17.5 Volts 16-33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 t 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 2of4 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135-185 cd) DC Input 16-33 Volts FWR Input 16-33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 1 295 Non-Temporal Low 214 1 229 256 1 262 HORN TONES AND SOUND OUTPUT DATA Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8-17.5 Volts 16-33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7' Coded High 82 82 88 88 93 92 101 8' Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. DIMENSIONS I l iIIIIIr Wall-mount horn strobes Wall back box skirt 3 of 4 ORDERING INFORMATION Fike P/N I Mfg. Model Description Wall Horn Strobes 20-1345 P2R 2-Wire Horn Strobe, Standard Cd, Red 20-1272 P2R-P 2-Wire Horn Strobe, Standard Cd, Red, Plain 20-1274 P2R-SP 2-Wire Horn Strobe, Standard Cd, Red, "FUEGO" 20-1269 P2RH 2-Wire Horn Strobe, High Cd, Red 20-1273 P2RH-P 2-Wire Horn Strobe, High Cd, Red, Plain 20-1276 P2W 2-Wire Horn Strobe, Standard Cd, White 20-1278 P2W-P 2-Wire Horn Strobe, Standard Cd, White, Plain 20-1277 P2WH 2-Wire Horn Strobe, High Cd, White 20-1279 P2WH-P 2-Wire Horn Strobe, High Cd, White, Plain 20-1280 P4R 4-Wire Horn Strobe, Standard Cd, Red 20-1284 P4R-P 4-Wire Horn Strobe, Standard Cd, Red, Plain 20-1281 P4RH 4-Wire Horn Strobe, High Cd, Red 20-1286 P4W 4-Wire Horn Strobe, Standard Cd, White Wall Strobes 20-1290 SR Strobe, Standard Cd, Red 20-1294 SR-P Strobe, Standard Cd, Red, Plain 20-1296 SR-SP Strobe, Standard Cd, Red, "FUEGO" 20-1291 SRH Strobe, High Cd, Red 20-1295 SRH-P Strobe, High Cd, Red, Plain 20-1297 SRH-SP Strobe, high Cd, Red, "FUEGO" 20-1298 SW Strobe, Standard Cd, White 20-1300 SW-P Strobe, Standard Cd, White, Plain 20-1299 SWH Strobe, High Cd, White 20-1301 SWH-P Strobe, High Cd, White, Plain Horns 20-1334 HR Horn, Red 20-1336 HW Horn, White Accessories 20-1339 BBS-2 Back Box Skirt, Wall, Red 20-1340 BBSW-2 Back Box Skirt, Wall, White 20-1986 TR-HS Trim Ring, Wall, Red 20-1987 TRW-HS Trim Ring, Wall White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard Cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. Copyright © Fike Corporation All Rights Reserved. 4 of 4 Form No. P.1.176.01, October 2013. Specifications are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0204 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.kireyev@honeywell.com DESIGN: Models LENS-B, LENS-R, LENS-G, LENS-A, LENS-BC, LENS-RC, LENS-GC, and LENS-AC retrofit colored strobe lenses for non-fire applications with all System Sensor SpectrAlert Advance models having -P' or "K-P' suffixes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: LENS-B: blue rectangular lens LENS-R: red rectangular lens LENS-G: green rectangular lens LENS-A: amber rectangular lens LENS-BC: blue circular lens LENS-RC: red circular lens LENS-GC: green circular lens LENS-AC: amber circular lens INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, and UL label. APPROVAL: Listed as retrofit colored strobe lenses for use with listee's separately listed and compatible strobe lights for non-fire applications. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. NOTE: Not approved for use as fire signaling devices for the hearing impaired. 10-17-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division F 0 F c DATA SHEET II AUDIBLE VISIBLE ACCESSORIES DESCRIPTION -1*.• The MP120K Mounting Plate is designed to use 120 VAC to power SpectrAlert Advance horns, strobes, horn Pir strobes, chimes, and chime strobes. ., • Color Lens Attachments install easily on any indoor or outdoor SpectrAlert Advance strobe devices to provide distinctive visual signaling. -- WTP Series Weatherproof Plates enable installers to flush mount outdoor horns, strobes, horn strobes, speakers, and speaker strobes to a variety of wall surfaces, including brick, ceramic tile, concrete, and masonry brick. These NEMA 3R-rated plates come in red and white to suit aesthetic and functional requirements. They may be used indoors or outdoors (with outdoor devices), as required by conditions. They easily attach to the SpectrAlert Advance universal mounting plate. Trim Rings for speakers and speaker strobes allow for additional space within the backbox. Trim rings for APPROVALS: horns, strobes, and horn strobes allow 4-wire devices to mount to a single-gang back box. UL-51383 SpectrAlert Advance Outdoor Back Boxes ensure a NEMA 4X watertight listing for AV devices. In locations FM -3006185 where you have a hard surface to mount to, Surface Mount Back boxes are the best solution. If you have an CSFM - 7272-0410107 exposed junction box, the Back Box Skirts offer an attractive solution to mask the junction box exposure. Retrofit Plates cover paint outlines on the wall when replacing legacy SpectrAlert Advance products. j SpectrAlert Advance DECALS are for use on our non-pad printed wall- and ceiling-mount devices. Each decal comes with AGENT, EVAC, ALERT, or FIRE label options. The Sync-Circuit Module synchronizes SpectrAlert Advance strobes at 1 Hz and horns and chimes at temporal 3 over a single pair of wires. Patented module FM technology also allows the silencing of horns or chimes on horn strobe and chime strobe models over a pair I of wires. See Datasheet A05-1007-005 for more information. APPROVED FEATURES MP120K Mounting Plate Designed for both indoor and outdoor use Plug-in design eliminates ground faults Power supply that converts 120 VAC to nominal 24 V FWR Compatible with all two-wire SpectrAlert Advance® devices Color Lens Attachments Easily turns any device into a strobe for ECS, severe weather, sprinkler activation and more Outdoor rated from —35F to 151F Wall- or ceiling-mount lenses available UL1638listed WTP Weatherproof Plates Enables flush mounting of outdoor devices to brick, ceramic tile, concrete, and masonry brick Weatherproof per NEMA 3R For use in both indoor and outdoor applications For use with all K series (outdoor) products replacement -R models Universal mounting plate easily attaches to the weatherproof plate SPECIFICATIONS MP12OK 120 VAC mounting plate model MP120K shall be listed to UL 464 for fire protective signaling systems. The mounting plate shall power a two-wire SpectrAlert® Advance horn, strobe, horn strobe, chime or chime strobe from a 120 VAC supply converted to nominal 24 V FWR. For indoor applications, the mounting plate shall be installed in a 4x4x21/8 -inch junction box. For outdoor applications, the mounting plate hill be installed using the proper SpectrAlert Advance outdoor weatherproof back box and outdoor listed notification appliance. Compatibility MP120K may be used with any of the following products at all horn and strobe settings: P2R, P211H P2RK, P2RHK, P2W, P2WH, SR, SRH, SRK, SRHK, SW, SWH, PC2R, PC2RH, PC2RK, PC2RHK, PC2W, PC2WH, SCR, SCRH, SCRK, SCRHK, SCW, SCWH, HR, HRK, HW, SR-P, SW-P, SRH-P, SWH-P, P2R-P, P2W-P, P2RH-P, P2VvH-P, SCR-P, SCW-P, SCRH-P, SCWH-P, PC2R-P, PC2W-P, PC2RH-P, PC2WH-P, SR-SP, SRH-SP, P2R-SP, P2RH-SP, SLVV-SP, SCWH-SP, PC2W-SP, PC2WH-SP, CHR, CHW, CHSR, CHSW. , Form No. P.1.171.01 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.fike.com Physical/Operating Specifications Standard Operating Temperature: Humidity Range: Nominal Voltage: Operating Voltage Range: Current Draw From AC Line: —40°F to 151°F (-40°C to 66°C) 10 to 93% non-condensing (indoor products) Regulated 120 VAC 96-132 VAC 150 mA max. WTP Weatherproof Plates The SpectrAlert Advance weatherproof plate for horns, strobes, and horn strobes shall mount to 4x4x11/4-inch and 2x4x11/2-inch back boxes. The weatherproof plate for speakers and speaker strobes shall mount to 4x4x21/8-inch back boxes. The weatherproof plate may be installed on brick, concrete, ceramic tile, and masonry brick and must be used with System Sensor "K" series outdoor replacement models (-R). Outdoor SpectrAlert Advance products shall operate between -40°F and 151°F. Physical Specifications Speaker Strobe: 7.25" Lx 6.26" W x 3.00" D (including speaker and lens) Speaker: 7.25" Lx 6.26" W x 1.30" D (including speaker) Horn Strobe: 6.90" Lx 5.90" W x 2.80" D (including strobe lens) Horn: 6.90" Lx 5.90" W x 1.60" D (including horn) Note: WTP and WTPW are compatible with 4411/4-inch and 2x4x11/2 -inch back boxes. (Compatible with outdoor horns, horn strobes and strobes) WTP-SP and WTP-SPW are compatible with 4x4x21/8-inch back boxes. (Compatible with outdoor speakers and speaker strobes) Models Available for Use with the Watertight Plates: WTP/WTPW: HRK-R WTP/WTPW: SRK-R, SRHK-R, SWK-R, SWHK-R WTP/WTPW: P2RK-R, P2RHK-R, P4RK-R, P2WK-R, P2WHK-R WTP-SP: SPRK-R, SPWK-R WTP-SPW: SPSRK-R Note: -R models ship without the outdoor back box. The weatherproof mounting plates are designed to be used only with -R replacement models. Color Lens Attachments The System Sensor SpectrAlert Advance color lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with non-FIRE-printed System Sensor strobe devices. The lens shall mount to any wall- or ceiling-mount strobes and shall be rated from —35°F to 151°F. Compatibility Color lens attachments may be used with the following System Sensor plain (non-FIRE-printed) indoor or outdoor strobe models: SR-P. SRH-P, SW-P, SWH-P, P2R-P, P2W-P, P2WH-P, P2RK-P, P2RHK-P, SCW-P, PC2R-P, PC2W-P, PC2WH-F SPSW-P, SPSR-P, SPSWH-P, SPSRH-P, SPSWV-P, SPSRV-P, SPSCW-P, SPSCWH-P, SPSCWV-P, SPSCWVH-P, SRK-P, SRHK-P, SWK-P, SWHK-P, P2WK-P, P2WHK-P, SPSWK-P, SPSRK-P, SW-CLR-ALERT, SCW-CLR-ALERT, SPSCW-CLRALERT. CANDELA RATING FOR UL 16385 Light output of color lenses is measured per UL 1638, on axis, and is not derated. Strobe Output (cd) Candela Switch Setting On-Axis Candela Rating (UL1638) - All Colors 15 15 15/75° NA 30 30 75 75 95 95 110 110 115 115 135 135 150 150 177 177 185 185 15/75 Candela setting not to be used with color lenses 2 of 4 ORDERING INFORMATION Fike P/N I Mfg. Model Description Metal Weatherproof Backboxes 20-1417 MWBBW white, wall-mount, compatible with: SPWK-R, SPWK, SPSWK-R, SPSWI<-P, SPSWK 20-1418 MWBB red, wall-mount, compatible with: SPRK-R, SPRK 20-1419 MWBBCW white, ceiling-mount, compatible with: SPCWK, SPSCWK,SPCWK-R, SPSCWK, SPSCWK-R, SPSCWHK, SPSCWHK-R 20-1975 SA- WBBW white, wall-mount, compatible with: P2WK, P2WHK, P2WHK-P, P2WK-P, SWK, SWK-P,P2WHK-R, P2WK-R, SWHK-R 20-1976 SA- WBB red, wall-mount, compatible with: P2RK, P2RK-P, P2RK-R, SRK, SRK-P, SRK-R P2RHK, P4RK, P4RHK, SRHK, HRK, P2RHK-R, P2RK-R, HRK-R, P4RHK-R, P4RK-R, SRHK-R SA-WBBCW white, ceiling-mount, compatible with: PC2WK, SCWK 20-1977 SA-WBBW white, wall-mount, compatible with: P2WK, P2WHK, P2WHK-P, P2WK-P, SWK, SWK-P,P2WHK-R, P2WK-R, Surface Mount Back Box 20-1978 SBBR red, wall-mount, compatible with: HR, CHR, SR, SR-SP, SRH, P2R, P2R-SP, P2RH, P4R, P4RH, CHSR, P211-P, SR-P, SRH-P 20-1979 SBBW white, wall-mount, compatible with:HW, CHW, SW, SWH, 132W, P2WH, P4W, P4W-P, CHSW, P2W-P, P2WH-P, SW-P, SWH-P, SW-ALERT, SWH-ALERT 20-1980 SBBSPR red, wall-mount, compatible with: SPR, SPRy, SPSR, SPSRH, SPSRV, SPSR-P, SPSRH-P, SPSRV-P 20-1981 SBBSPW white, wall-mount, compatible with: SPW, SPWV, 585W, SPSWH, SPSWV, SPSW-P, SPSWH-P, SPSWV-P, SPSW- ALERT, SPSW-CLR-ALERT 20-1982 SBBCR red, ceiling-mount compatible with: SCR, SCRH, PC2R, PC2RH, PC4R, PC4RH, SPCR, SPCRV, SPSCR, SPSCRH, SPSCRV, SPSCRVH, PC2R-P 20-1983 SBBCW white, ceiling-mount, compatible with: SCW, SCWH, PC2W, PC2W-SP, PC2WH, PC4W, SPCW, SPCWV, SPSCW, SPSCWH, SPSCWV, SPSCWVH, PC2W-P, PC2WH-P, SCW-P, SPSCW-P, SPSCWH-P, SPSCWHK-P, SPSCWV-P, SPSCWVH-P, SPSCW-CLR-ALERT, SCW-CLR-ALERT Back Box Skirts 20-1339 - BBS 2 red, wall-mount, compatible with: P2R, SR, HR, CHSR, CHR, P2RH, P4R, P4RH, SRH, P2R-P, P2RH-P, P4R-P, P4RH-P, SR-P, SRH-P, SR-SP, SRH-SP, P2R-SP, P2RH-SP 20-130-131 BBS-SP201W Surface-mount back-box skirt for the PF24V (ExitPoint" Directional Sounder with Voice Messaging) 20-1459 SPBBS red, wall-mount, compatible with: SPR, SPSR, SPRV,SPSR-P,SPSRH,SPSRH-P Colored Lenses 20-1814 LENS-B Wall-mount, blue 20-1819 LENS-R Wall-mount, red 20-1820 LENS-G Wall-mount, green 20-1821 LENS-A Wall-mount, amber 20-1822 LENS-BC Ceiling-mount, blue 20-1823 LENS-RC Ceiling-mount, red 20-1824 LENS-GC Ceiling-mount, green 20-1816 LENS-AC Ceiling-mount, amber Decals (*all decals include labels: "AGENT, EVAC, ALERT & FIRE" 20-1826 DECAL-R red, used for non-pad-printed wall-mount devices. (10 total decals per box for 5 devices)* 20-1827 DECAL-RC red, used for non-pad-printed ceiling-mount devices. (15 total decals per box for 5 devices)* 20-1828 DECAL-W white, used for non-pad-printed wall-mount devices. (10 total decals per box) for 5 devices" 20-1829 DECAL-WC white, used for non-pad-printed ceiling-mount devices. (15 total decals per box for 5 devices)* Retrofit Plates (For use with horn strobe & speaker strobe devices) 20-1454 RFPW 9.5" x 7" white 20-1455 REP 9.5" x 7" red Mounting Plates 20-1845 MP120K 120 VAC Adapter Mounting Plate 3 of 4 Fike P/N Mfg. Model Description Sync Modules 20-1490 MOL3W white, 12/24 volt Sync-Circuit module. 20-1489 MDL3R red 12/24 volt Sync-Circuit module Trim Rings 20-1461 TR red, wall-mount for use with speaker devices 20-1463 TRC red, ceiling-mount for use with speaker devices 20-1984 TRC-HS red, ceiling-mount for use with horn strobe devices 20-1462 TRCW white, ceiling-mount for use with speaker devices 20-1985 TRCW-HS red, ceiling-mount for use with horn strobe devices 20-1986 TR-HS red, wall-mount for use with horn strobes devices 20-1460 TRW white, wall-mount for use with speaker devices 20-1987 TRW-HS white, wall-mount for use with horn strobe devices Watertight Plates 20-1988 WTPW white, for use with horn, strobes & horn strobe devices 20-1869 WTP red, for use with horn, strobes & horn strobe devices 20-1989 WTP-SPW white, for use with speaker devices 20-2024 WTP-SP red, for use with speaker devices Copyright © Fike Corporation All Rights Reserved. 4 of 4 Form No. P.1.171.01, October 2013. Specifications are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walllrim Rings: TR2 and TR2W Ceilinglrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features ii r • IItt Itti F J1It:iltl F 1 2 R E - . '11 H r Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices Compatible with MDL3 sync module Listed for wall mounting only Agency Listings SIGNALING LISTED S5512 FM approved except 7125-1653:0504 54017 for ALERT models 7135-1653:0503 3057383. 3057072 The System Sensor L-Series otters the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With whi:e and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series car- meet virtually any application recuirement. The L-Series line of wall-mount horns, strobes, and horn s.robes include a variety of features that ncrease their applicatior versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually elimi]ating costly and time-ccnsurning ground faults. To further simplify installation and protect devices from ccnstruction damage, the [-Series utilizes a universal mounting plate hr all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt cevices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24--jolt operation, and a rotay switch for horn tones with two volume selections. Specifications Architect/ruiinpr Sncifieit,on General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/e-inch back box, 4 x 4 x 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash oer second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1'2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 1.91 "D (143 mm Lx 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46" W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"Wx 1.25"D (143 mm Lx 119mmWx 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" D (133mm Lx 88mm W x 32mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data TTJ 8-175 Volts 16-33 Volts 8-175 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 T1 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd llQcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.1KTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.lKTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions -1.91 -3.46 -a 1.25 5.27 LLJ Compact Strobe I Horn Strobe -4.70 - 1.91 1.25 5.67 I. If Strobe / Horn Strobe L-Series Ordering Information -- Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT 5 Compact Horn Horn T1 Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have "ALERT" marking on cover 3825 Ohio Avenue • St. Charles, IL 60174 ©2017 syslerrr sensor. Phone 800-SENSOR2 • Fax 630-377-6495 Product0pachcvhions subject lo change without notice. Visit systernueosor.corn AE 315OAR° or current product information, including the latest versional this data sheet. www.systemsensor.com AvDS86503 • 03/17 L:L [03RATEPWISCI4*11 HFC-227EA CLEAN AGENT APPROVALS: UL Listed ULC Listed DESCRIPTION • FM Approved HFC-227ea provides superior fire protection in a wide range of applications from sensitive electrical equipment to industrial applications using flammable liquids. HFC-227ea is ideal for applications where clean-up of other media presents a problem, where weight versus suppression potential is a factor, where an electrically non-conductive medium is needed and where people compatibility is an overriding factor. When environmental impact is a consideration, HFC-227ea is particularly useful. It has zero ozone- depleting potential, low global warming potential and a short atmospheric lifetime. These characteristics make it suitable not only for new installations using Fike's total flooding systems, but also for Halon 1301 replacement appIictions. HFC-227ea is an odorless, colorless, liquefied compressed gas. (See Physical Properties Table for additional information). It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. HFC-227ea extinguishes a fire by a combination of chemical and physical mechanisms. HFC-227ea does not displace oxygen and therefore is safe for use in occupied spaces without fear of oxygen deprivation. FEATURES AND BENEFITS Colorless, odorless, liquefied compressed gas Stored as a liquid Electrically non-conductive Discharges as a gaseous vapor (due to its relatively low boiling point) Zero ozone depleting potential Low global warming potential Included on the U.S. EPA Significant New Alternative Policy (SNAP) rules EXTINGUISHING METHOD - HFC-227ea HFC-227ea extinguishes a fire primarily through Heat Absorption that occurs as the agent changes from a liquid to a vapor during discharge. In addition, HFC-227ea also disrupts the combustion reaction which aids in the extinguishment of a fire. It is important to note, HFC-227ea does not use the depletion of oxygen to extinguish a fire. USE AND LIMITATIONS - HFC-227ea HFC-227ea system shall be used on the following Class of Hazards: Class A & C: Electrical and Electronic Hazards Telecommunications Facilities High value assets, where the associated down-time would be costly Class B: Flammable liquids and gases HFC-227ea systems shall "NOT" be used on fires involving the following materials: Chemicals or mixtures of chemicals that are capable of rapid oxidation in the absence of air. (Examples include: Cellulose Nitrate and Gunpowder) Reactive metals such as Lithium, Sodium, Potassium, Magnesium, Titanium, Zirconium, Uranium, and Plutonium Metal hydrides such as Sodium Hydride and Lithium Aluminum Hydride Chemicals capable of undergoing auto-thermal decomposition. (Examples: Organic Peroxides and Hydrazine) 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.fike.com LISTED APPROVED EXPOSURE LIMITATIONS Hazard Type Design Concentration Maximum Human I Expose Time I Normally Occupied Space 6.25% to 10.5% 5 minutes Normally Un-Occupied Space 11.0% to 12.0% 30 seconds Note: Fike does not recommend HFC-227ea systems to be used in any normally occupied spaces where the design concentration rquired is above 10.5% Warning: The discharge of clean agent systems to extinguish afire can result in potential hazard to personneifrom the natural form of the clean agent or from the products of combustion that result from exposure of the agent to the fire or hot surfaces. Unnecessary exposure of personnel either to the natural agent or to the products of decomposition shall be avoided. PHYSICAL PROPERTIES Chemical Name/Formula Heptafiuoropropane / CFCHFCF3 ASHRAE Designation HFC-227ea CAS Number 431-89-0 Molecular weight 170.03 Vapor Density @ 25'C (77'F) and atm, kg/m3 (lb/ft') 7.148 (0.4462) Boiling Point, 1 atm, 'C ('F) -16.4(2.5) Melting Point, 'C ('F) -131(-204) Critical Temperature, 'C ('F) 101.6 (214.9) Critical Pressure, kPa (psia) 2930 (424.7) Critical Density, kg/ml (lb/ft') 621 (38.77) Liquid Density @ 25'C (77'F), kg/m3 (lb/ft') 1386(86.53) Vapor Density @ 25'C (777) and 1 atm, kg/m' (lb/ft') 7.148 (0.4462) Specific Heat, Liquid (Cp) @ 25'C (777), Id/Kg- 'C (Btu/lb'F) 1.247 (0.2979) Specific Heat, Vapor (Cp) @ 25'C (77'F) Id/Kg- 'C (Btu/lb'F) and 1 ATM 0.8136 (0.1945) Vapor Pressure, Saturated @ 25'C (77'F), kPa (psia) 453.3 (65.7) Heat of Vaporization @ Boiling Point Id/Kg (Btu/lb) 132.6 (56.7) Thermal Conductivity, Liquid @ 25'C (777), W/m- 'C (Btu/hr-ft'F) 0.0533 (0.0308) Thermal Conductivity, Vapor @ 25'C (777), w/m- 'C (Btu/hr-ft'F) 0.0127 (0.0073) Viscosity, Liquid @ 25'C (777), cP (lb/ft-hr) 0.2442 (0.5907) Relative Dielectirc Strength @ 1 atm, 25'C (N2=1) 2.00 Solubility of Water in HFC-227ea @ 20'C (68'F), ppm 600 Ozone Depletion Potential 0.0 Global Warming Potential (based on a 100-yr ITH for CO2, GWP = 1) 2900 Copyright © Fike Corporation All Rights Reserved. 2 of 2 Form No. IV.1.02.01-2, August 2012. Specifications are subject to change without notice. IrT0fl DATA SHEET I AGENT STORAGE CONTAINERS WITH HFC-227EA DESCRIPTION Fike Clean Agent Containers are used in fire extinguishing systems to store the Clean Agent until a fire develops and the agent must be released The Clean Agent is retained in the container by a Impulse Valve assembly which contains a fast acting rupture disc The disc will be ruptured and the Clean Agent released through the operation of an actuator by an electric signal that is automatically, manually or pneumatically controlled. Fike Clean Agent Containers have passed extensive testing by Factory Mutual and Underwriters Laboratory and are used in installations where 3 to 1045 pounds (2.0 to 474 kg) of HFC-227ea agent is required. Clean Agent containers can be filled in 1 pound (0.5 kg) increments to their maximum capacity. SPECIFICATIONS Fill Range: 40 to 70 lbs/ft3 (630 to 1121 kg/m3) Fill Increments: 1.0 lbs (0.5 kg) Container Super - Pressurization Level: 360 psig at 70°F (24.8 bar at 21°C) after filling with dry nitrogen Container Storage Temperature Limitation: 32°F (0°C) - minimum, 130°F (54.4°C) - maximum APPROVALS: Note If container temperatures exceeding 130 F (54 4 C) valve will open automatically, this also fulfills the pressure relief UL Listed valve requirements in accordance with DOT regulations. ULC Listed FM Approved Container Construction: Carbon Steel Alloys Paint Options: Baked enamel finish white (default) or red Container Ratings: DOT 4BW500 TC4BWMS34 Actuation Methods: Electric/Pneumatic/Manual LISTED APPROVED ... . .• Form No 1V101014 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. . . Phone: 8162293405 • www.fike.com CONTAINER DATA/SPECIFICATIONS Container Fill range Dimensions Valve Size Tare Weight (approximate) Mounting Size Minimum Maximum Diameter Height Position P/N lbs. (kg) lbs. (kg) IN (mm) lbs. (kg) IN (mm) IN (mm) 5 3 5 1 11 4.2 16.2 Upright (2) 70-272 (2.0) (2.5) (25) (5.0) (102) (411.5) (Valve Up) 10 6 10 1 15 4.2 27.24 Upright (4) 70-273 (3.0) (4.5) (25) (6.8) (102) (691.9) (Valve Up) 20 70-263 12 21 1 22 7.0 22.50 Upright - (8.5) (5.5) (9.5) (25) (10.0) (178) (571.5) Horizontal 35 22 38 1 32.5 7.0 33.75 Upright - (15) 70-264 (10.0) (17.0) (25) (14.7) (178) (857.3) Horizontal 60 39 68 1 52.5 10.75 28.13 Upright - (27) 70-265 (18.0) (30.5) (25) (23.8) (273) (714.4) Horizontal 100 63 108 1 77 10.75 39.63 Upright (44) 70-266 (28.5) (49.0) (25) (34.9) (273) (1006.5) (Valve Up) 150/150i 70-267 87 150 3 118/114 20.0 24.25 Upright/Inverted (61) (39.5) (68.0) (80) (53.5/51.7) (508) (616.0) 215 124 216 3 146 20.0 30.13 Upright (88) 70-268 (56.5) (98.0) (80) (66.2) (508) (765.2) (Valve Up) 375 70-269 217 378 3 213 20.0 43.38 Upright (153) (98.5) (171.5) (80) (96.6) (508) (1101.7) (Valve Up) 650 70-270 378 660 3 373 24.0 50.50 Upright (267) (171.5) (299.0) (80) (169.2) (610) (1282.7) (Valve Up) 1000 70-271 598 1045 3 535 24.0 71.88 Upright (423) (271.5) (474.0) (80) (242.7) (610) (1825.6) (Valve Up) 2 of 7 Item 6 ITEMS SUPPLIED WITH CONTAINER ASSEMBLY Item Number Description Data Sheet 1 Victaulic Coupling & Nipple IV.1.19.01 2 Impulse Valve V.1.14.01 3 Pressure Gauge V.1.13.01 4 Liquid Level Indicator (LLi) C.1.40.01 5 LLi Boss (see note 1( n/a 6 Nameplate (see note 2( n/a 7 Siphone Tube (see note 3( n/a 8 Mounting Straps & Brackets IV.1.18.01 Notes: 100 thru 1000 lb. (44 thru 423 L) containers are equipped with a LLi Boss. Fike nameplate provides the information that is specific to each container: Assembly and serial number of the container, weight information: tore, gross and agent and installation, operation and safety information. All containers filled either by the factory or by on Approved Initial Fill Station are provided with a name plate bearing the UL & FM markings. Fike Clean Agent containers [except the 150/ (Inverted)] are equipped with a siphon tube. The 20, 35 & 60/b. containers have bent siphon tubes and the 5, 10 and 100- 1000 lb. containers hove straight siphon tubes. All containers with siphon tubes can be mounted upright. The 20, 35 & 60 lb containers can also be mounted horizontally. The 150 container can only be mounted upright and the 150i can only be mounted inverted. Item Item Item 3 i Item 4 *— Item 5 Item B 3 of 7 OPTIONAL ITEMS FOR CONTAINER The following container accessory items must be ordered separately. ACTUATION COMPONENTS Electric! Manual Actuation -Impulse Valve Operator (IVO) (For detailed information, refer to the IVO Data Sheet IV.1.09.01) Impulse Valve Operator (IVO) t Container WI Impulse Valve Pneumatic Actuation - Impulse Valve Pneumatic Operator (IVPO) (For detailed information, refer to the IVPO Data Sheet V.1.10.01) Container w/ Impulse Valve \ Impulse Valve Pneumatic Operator (IVPO) ACTUATION METHODS Clean Agent containers with an Impulse Valve can be actuated by the following methods: Method 1— Electric Actuation - Single Container System w/ IVO & IRM Method 2— Electric Actuation - Multi-Containers System w / IVO & IRM Method 3— Electric & Pneumatic Actuation - Two Container System w/ IVO & IVPO Method 4— Electric & Pneumatic Actuation - Multi Container System w/ IVO & IVPO For detailed information on actuation methods, refer to the Impulse Valve Operator (IVO) data sheet V.1.09.01. These devices provide the force required to extend a pin that will open the rupture disc, allowing the agent to be released from the container. 4 of 7 LOW PRESSURE SWITCH The Low Pressure Switch provides a means to continuously monitoring the container pressure for a low-pressure condition. Low Pressure Switch If the pressure inside the container drops below 288 psig (1986 kPa), the switch contacts will transfer and invoke a "trouble" indication on the control panel. The Low Pressure Switch (P/N 02-12533) has a single pole, double-throw switch that can be wired for normally open or normally closed. For detailed information, refer to the Low Pressure Switch Data Sheet IV.1. 13.01. INSTALLATION The system installation must comply with the requirements of this manual; NFPA 2001, latest edition; all applicable local codes, regulations, and standards and the authority having jurisdiction (AHJ). Container WI Impulse Valve Warning: DO NOT start system installation until the final design of the total system has been verified using Fike's Engineered Flow Calculation. Warning: The Actuator shall always be the last component installed on a Fike Clean Agent Fire Suppression system to avoid accidental discharge. Factors to Consider - Container Location Mounting Surface: Container brackets must be mounted securely to solid load-bearing surfaces that will support the container load. Some installations may require additional mounting support not supplied by Fike. Environmental Effects: Container(s) should be located in clean, dry, and relatively vibration-free areas. Avoid aisle ways and other high traffic areas where physical damage or tampering is more likely. Container(s) should never be mounted where the container could potentially be splashed with, or submerged in any liquid. Do not locate containers where they would be subject to physical damage, exposure to corrosive chemicals, or harsh weather conditions. Temperature Range: Container locations must be between 32 to 130"F (0 to 54.4"C). Temperatures outside of this range may result in the system not supplying the desired quantity of agent or accidental discharge. Serviceability: In general, the larger the container, the more difficult it will be to remove it from the system for maintenance and service. However, smaller containers that are located in a sub-floor space, under a computer bank, or above the ceiling over the same computer bank can be difficult as well. Floor Space: Consideration should be given to the space available to install the container(s). For example, a 900 lb. (408 kg) system could be stored in (2) 650 lb. (267 L) containers located on the floor. However, if floor space is a problem, the system could be designed to utilize (6) 150i lb. (61 L) Inverted Containers mounted on the wall(s). Floor Loading: Floor loading must be considered when selecting a container location. The floor must be able to support the total weight of the Fike container(s) as they are moved into position. Consult raised floor manufacturer for floor loading limitation. The following guidelines are recommended: Raised floor loading is a function of the manufacturer's load specification and the positioning of the container(s) on the raised floor grid. Note: Fike cannot assume responsibility for determining the suitability of o particular raised floor system; the following does provide information to help determine installation requirements. When clean agent containers are located on a raised floor, floor integrity must be considered to determine if the type of tile and vertical floor support can handle the increased load. If necessary additional floor supports can be added. Option: To help distribute the container weight over a greater area, a 'h" steel plate can be placed under the container(s), sized to span multiple floor supports. If container spans multiple floor tiles, add additional floor supports (Minimum of 4 floor supports, 1 per corner, must be used). Excessive floor loading may require relocating the container(s) to a more suitable location. For floor loading information refer to the table on page 6 or to Fike's ECARO-25 Flow Calculation program for container size and actual fill weight being supplied. 50f7 Container Floor Area Container w/ Plate Container Size Total Container weight Container Floor Container Floor w/ Plate 1/4: x 2'x 2' plate Floor lb. (1) lbs. (kg) Area Loading (6.4mm x 0.6m x 0.6m Loading see note 1 ft' (m') lbs/ft2 (kg/ml) plate) lbs/ft2 (kg/ml) ft, (MI) see note 2 1000(423) 1386 (628) 3.14 (0.29) 508(2493) 4.0(0.36) 404 (2037) 650 (267) 913 (41) 3.14 (0.29) 333 (1636) 4.0 (0.36) 267 (1467) 375 (153) 527 (239) 2.18)0.20) 277 (1368) 4,0 (0.36) 156 (788) 215 (88) 328 (148) 2.18 (0.20) 170(840) 4.0 (0.36) 98(495) 150 (61) 283 (128) 2.18 (0.20) 138(680) 4.0(0.36) 81 (406) 100)44) 164 (74) 0.63 (0.06) 294)1400) 4.0 (0.36) 52(262) 60)27) 106 (48) 0.63 (0.06) 190)908) 4.0 (0.36) 36(180) 35 (15) 51 (23) 0.27 (0.03) 256 (115) 4.0 (0.36) 23(114) 20(8.5) 37 (17) 0.27 (0.03) 156 (72) 4.0)0.36) 16(83) 10(4) 23 (11) 0.10 (0.009) 250 (1278) 4.0 (0.36) 12)60) 5 (2) 15 (7) 0.10 (0.009) 160 (833) 4.0 (0.36) 10(49) Notes: Total container weight is based on container tore weight + maximum fill weight Total container weight + 22.5 lbs (10.2 kg) added for 114"x 2'x 2' (6.4mm x 0.6m x 06m) plate used to calculate container with plate floor loading 6 of 7 Item 2— Disc Assembly 0 (DO Item 3-0-Ring (.'.....: \ RECHARGE ITEMS - 1 IN (25) & 3 IN (80) VALVE (Must Order Separate) After a system has been discharged, the following items must be replaced before a container can be recharged. For a detailed procedure on recharging a Fike container w/ an Impulse Valve refer to Fike's Recharge Manual (p/n 06-290). Item Description 1 IN (25mm) Recharge Kit (P/N 85-047) includes the following: 3 IN (80mm) Recharge Kit (P/N 85-048 includes the following: Part Number Part Number 1 Friction Ring 70-2060 70-2063 2 Disc Assembly 70-247 70-248 3 0-Ring 02-11987 02-11989 4 Valve Core-Fill Port (not shown) 02-4161 02-4161 5 Reconditioning Instructions (not shown) 06-567 Note: I IN Recharge Kits used on 5, 10, 20, 35, 60 & 100/b. (2, 4, 8, 15, 27 & 44 L) containers 3 IN Recharge Kit .s used on 150, 1501, 215, 375, 650 & 1000/b. (61, 61i,88, 153, 267 & 423 L) containers Item I - Friction Ring Copyright © Fike Corporation All Rights Reserved. 7 of 7 Form No. lV.1.01.01-4, February 2012. Specifications are subject to change without notice. DATA SHEET I IMPULSE VALVE DESCRIPTION The 1" and 3" Impulse Valves are a rupture disc (metal diaphragm), pressure operated device that allows the .. agent to be released from the container and into the protected enclosure via the associated piping network and discharge nozzle(s) '- Fike Impulse Valves are equipped with four ports '-. - Agent Discharge Port allows agent release from container and also fulfills the pressure relief valve requirements in accordance with DOT regulations. Agent Fill Port used to fill (refill) and pressurize the container and also used for the Low Pressure Switch. Actuator Port used to connect an Impulse Valve Operator (IVO) with Manual Strike Button for electric and manual actuation of the container or an Impulse Valve Pneumatic Operator (IVPO) for pneumatic operation. Pressure Gauge Port is used to connect a Pressure Gauge that will monitor internal container pressure, also equipped with an orifice plug that allows the pressure gauge to be removed safely when the container is pressurized. APPROVALS: UL Listed SPECIFICATIONS ULC Listed Valve Body: Brass FM Approved Rupture Disc Assembly: Hastelloy® C276/316 SST Discharge Port LISTED -1 Pressure Gauge Part Flit Port ._____9!,, i impui e valve Rupture Disc Assembly APPROVED 4 Discharge Port lk& S Pressure Gauge 0 Fill Port Pressure Gauge Port t 31 Impulse Valve Actuator Port Form No lV1 14011 704 SW 10th Street • P.O.Box 610 • Blue Springs Missouri 64013-0610 U.S.A. Phone: 8162293405 • wvw.fike.com Ping -Fill PQ ____________ Rupture Disc Assembly 1 Valve Core -Fill Pout Actuatou Pin Internal View - 1' Impulse Valve Rupiule Disc Assembly Ping — Fill Pout LI I Actuator Pun Valve Core - Fill Pout . ... Internal View - 3 impulse Valve Copyright © Pike Corporation All Rights Reserved. 2 of 2 Form No. IV.1.14.01-1, August 2012. Specifications are subject to change without notice. HFC-227ea 360' nozzle / rT L tK ENGINEERED NOZZLES FOR HFC-227EA DESCRIPTION The function of the Fike discharge nozzle is to control the agent flow and distribute the agent throughout the protected enclosure in a uniform, predetermined pattern and concentration. Nozzles are made of brass and have the Fike logo forged into two hex flats. The discharge nozzle size refers to the size of schedule 40 or 80 pipe that it can be connected to. The discharge nozzle is mounted to allow the agent to be discharge on a horizontal axis. The nozzle orifice area is determined by performing a hydraulic calculation using the Fike Engineered Flow Calculation program. Nozzle should not be ordered until the clean agent system pipe network is installed and an "As Built" hydraulic calculation is performed. Nozzle orifice drilling must be done at Fike factory, or at a UL listed nozzle drill station. ORDERING INFORMATION Nozzle Size in. (mm) 360' Engineered Nozzles (12 Orifices) 180' Engineered Nozzles (11 Orifices) Nozzle Length (Approx.) in. (mm) Part Number Part Number 3/8(10) 80-091-XXXX 80-098-XXXX 1.38 (35.1) 1/2(15) 80-092-XXXX 80-099-XXXX 1.63 (414) 3/4(20) 80-093-XXXX 80-100-XXXX 1.88 (47.8) 1(2S) 80-094-XXXX 80-101-XXXX 2.19 (55.6) 11/4(32) 80-095-XXXX 80-102-XXXX 2.69 (68.3) 11/2(40) 80-096-XXXX 80-103-XXXX 2.94 (74.7) 2 (50) 80-097-XXXX 80-104-XXXX 3.13 (79.5) Material Brass Threads NPT HIC 227ea 180' Nozzle APPROVALS: UL Listed ULC Listed FM Approved 1W1iThFTI LISTED APPROVED Form No, IV.1.2 1.01 704 SW 10th Street * P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 e www.fike.com 4 0 INSTALLATION Always verify the nozzle identification number (stamped on the closed end of the nozzle) matches the nozzle part number listed on the system installation plans. All nozzle locations should be within 1'- 0" (0.3m) of their intended locations on the system plans. Discharge Nozzles must be mounted in the vertical position and can face either up or down. Caution: The piping should be blown clear to remove chips, mill scale, or metal shavings before the nozzles are installed 3600 NOZZLES 3600 Nozzles should be located in a symmetrical, or near symmetrical, pattern within the protected area. Nozzle patterns need to overlap, to adequately cover the area without any "blind spots" due to nozzle locations. Apply to all Nozzle types. RAISED FLOOR /.NOZZLE SU CENTER, OF BFLOOSPACE II SUPPORT PIPE I 7 NOZZLE ON RAISED FLOOR SUPPORT STANCHION FLOOR FLOOR BRACKET SUBFWOR NOZZLE SUPPDRT.. BRACKET " SUSPENDED CEILING 12' (30.5 err NOZZLE WITH DEFLECTOR PLATE NOTE: NOT UI, LISTED. MAY ES FLUSH MOUNTED, CEILING NOZZLE / / I .., . . . / •"0 // 'S / '• . .'.. . . _-•' I ' I —> I I <—•--> / 0_• " 0 , ". 2 of 4 1800 NOZZLES 1800 Nozzles should be located in a symmetrical, or near symmetrical, pattern within the protected area. 180 Nozzles should be located along the perimeter of the area - discharging along the perimeter and toward the opposite side. These nozzles can be located a maximum of l'-O" (0.3 m) out from the wall. 11 1.0' (0.3 m) Maximum 180° NOZZLES - BACK TO BACK APPLICATION 180 Nozzles can be installed in a back to back arrangement within the following limitations: Maximum distance between nozzles = 1.0' (0.3 m) Agent supplied and flow rate from both nozzles are the same. Pipe size from tee to both nozzles is the same. Pipe lengths from tee to each nozzle are within 10% of each other. / R NOZZLE SET SCREW Verify the Set Screws found on the side of the nozzle are in place after system installation. Warning: Failure to have the set screws in place will affect agent distribution and possibly the system's ability to suppress the fire. Set Screws to be flush with inside Wall Nozzle 3 of 4 NOZZLE AREA COVERAGE Nozzle Size - 3/8" - 2" (10-50mm) Radius "R" Ceiling Height Range Nozzle Type Dimensions ft.(m) ft. (m) 180' 45.67 (14) 1.0 to 16.0(0.3 to 4.9) 360' 29.67(9) 1.0 to 16.0(0.3 to 4.9) Maximum Distance 180' Nozzle 360' Nozzle Below ceiling 1.0 (0.3 m( 1.0 (0.3 m( Away from Sidewall 1.0(0.3 m) - 40-0" 44'- 0" 44'- 0" Copyright 10 Fike corporation All Rights Reserved. 4 of 4 Form No. IV.1.03.01-2, August 2012. Specifications are subject to change without notice. jo.2 Li IMPULSE VALVE OPERATOR (IVO) KIT DESCRIPTION The Impulse Valve Operator (IVO) provides means to electrically or manually activate the Fike Impulse Valve clean agent container by providing the force required to extend a piston that will open the rupture disc, allowing the agent to be released from the container. The IVO can be activated electrically via a signal from Fike control panel or manually by depressing red strike buttom. Fike Clean Agent Containers with Impulse Valve must use an Impulse Releasing Module (IRM) to supervise the agent release circuit wiring (for open and ground fault conditions) from the container to the control panel. The Impulse Valve Operator Supervisor (IVOS) is used to monitor the presence of the Impulse Valve Operator (IVO). When installed between the Impulse Valve and the IVO, this supervises the position of the actuation device; when the IVO is removed from the container this will cause a "supervisory event" at the system control panel. IMPULSE VALVE OPERATOR (IVO) KIT (p/n 70-279) Item No. Part Number Description 1 02-12728 Impulse Valve Operator (IVO) 2 02-12755 DIN Connector w/ Wire Lead (5' 1g.) 3 10-2748 Impulse Releasing Module Assembly (IRM) 4 02-14263 Impulse Valve Operator Supervisor(IVOS) 5 70-286 Reset Tool 6 02-13130 Cotter Pin 7 02-2213 Security Tie 8 02-12925 Plastic Cap (Black) Temperature Range 32°F to 130°F (0°C to 54.4°C) Listings & Approvals UL/ ULC Listed & FM Approved SPECIFCATIONS - IMPULSE VALVE OPERATOR (IVO) (p/n 02-12728) Normal Supply Voltage 24 VDC Current Consumption 0 Amps (for Battery Calculation) Electrical Connection DIN Connector w/ Cable & '/z" NPT for conduit connection IVO Material Stainless Steel (Body)! Brass (End Cap) SPECIFCATIONS - IMPULSE VAVLE OPERATOR SUPERVISOR (IVOS)(p/n 02-14263) Switch Normally Closed (Black) / Normally Open Contacts (White)! Common (Red) Conduit 0.25"ID SST Flexible Conduit 34.75" 1g. with 1/2" Knockout Connector Wire Leads 22 AWG, 44" 1g. Form No. V.1.09.01-2 704 SW 10th Street, P.O. Box 610, Blue Springs, Missouri 64013-0610 U.S.A. Phone: (816) 229-3405 • www.fike.com INSTALLATION After the electrical / control system has been checked out and no supervisory events / ground faults are present; proceed with the actuation s ystem installation. NOTE: This shouldi be the last items completed before the system is placed into operation. IMPORTANT NOTE: Check to ensure IVO is armed (Firing Pin retracted) and Safety Pin is place before installing to the Impulse Valve on the container. Install the wire leads from the IVOS to the control unit. (Refer to manuals 06-431 and 06-433 for wiring details) Install the wire leads from DIN connector to IRM. Install DIN connector onto IVO and secure with set screw. Remove retaining clip and plastic plug from Impulse Valve actuation port. Insert IVO into Impulse Valve actuation port and insert IVOS. The container is "NOW ARMED". Impulse Valve Operator - - Supervisor ____________ Impulse Valve (IVOS) Actuator Port . Impulse Valve Operator (IVO) MAL ' 2 of 6 ELECTRIC ACTUATION - SINGLE CONTAINER SYSTEM W/ IVO For wiring installation details between Fike Control Panel, IRM and the IVO, reference the Impulse Release Module product manual (p/n 06- 552). At this point the IVO can be installed to the Clean Agent Container Impulse Valve. The Discharge Pressure Switch (p/n 02-12534) is required and is wired to the manual release contact in SHP PRO or to a monitor module in Cheetah Xi or Xi50. WARNING: Do not attempt to install the IVO with the firing pin in the extended position. IRM Assembly Discharge Pressure Switch r 94- IVO w/ Manual Strike Button ELECTRIC ACTUATION - MULTI- CONTAINER SYSTEM W/ IVO Fike Control Panel To next IRM Assembly I L__ I -- r--------------- - v. IRM Assembly I I \/ 4 4t '4 A /' IVO w/ Plastic Cap / Manual Strike Button removed (Typical for containers) IMPORTANT NOTE: When utilizing electric actuation (IRM) with multiple containers with IVO, the manual strike button on each IVO must be removed and plastic cap installed. The Discharge Pressure Switch is NOT used. This is to prevent a single container from being discharged in a multiple container system. For wiring installation details between Fike Control Panel, IRM and the IVO, reference the Impulse Release Module (IRM) Product Manual (p/n 06-552). At this point the IVO can be installed to the Clean Agent Container Impulse Valve by referring the detailed installation instructions on page 2 of this data sheet. 3 of 6 ELECTRIC & PNEUMATIC ACTUATION - TWO CONTAINER SYSTEM W/ IVO & IVPO ITEM PART NUMBER DESCRIPTION 1 02-4530 '4" NPT x '4" JIC Adaptor (must be ordered separately) 2 02-4977 %" JIC x 3.0' 1g. Actuation Hose (supplied w/ IVPO kit)(see note) 3 02-4535 1/8" NPT x '4" JIC Adaptor (supplied w/ IVPO kit) 4 02-12926 '4" JIC Male Adaptor (must be ordered separately) NOTE: This actuation method requires 2 - %" JIC x 3.0' 1g. Actuation Hoses, 1 hose supplied w/ IVPO assembly, the 2d Actuation Hose must be ordered separately. 1--- Fike Control Panel l._ IRM Assembly Adaptor Nipple w/ —0' 1 2 (see note) 'A" Plug —4p 4 2 3 - vpo IVO w/ Manual Strike - - - -, Button Discharge Pressure Switch >'-t. NOTE: Install Discharge Pressure Switch on Container w/ IVPO First remove the 'A" NPT Plug from adaptor nipple, and then install actuation system as shown above. Secure actuation tubing to a solid surface. Anchoring into plaster, sheetrock wall or any other facing material is NOT acceptable. For additional information regarding the installation and resetting of the IVPO, refer to manuals 06-431 and 06-433. The Discharge Pressure Switch (p/n 02-12534) is required and is wired to the manual release contact in SHP PRO or to a monitor module in Cheetah Xi or Xi50. 4 of 6 ELECTRIC & PNEUMATIC ACTUATION - MULTI CONTAINER SYSTEM W/ IVO & IVPO ITEM PART NUMBER DESCRIPTION 1 02-4530 '4" NPT x ',4" JIC Adaptor (must be ordered separately) 2 02-4977 %" JIC x 3.0' 1g. Actuation Hose (supplied w/ IVPO kit) (see note) 3 02-4535 1/8" NPT x ¼" JIC Adaptor (supplied w/ IVPO k1t99999) 4 CO2-1359 'A" Tube Tee (must be ordered separately) 5 CO2-1356 'A" Male JIC x 'A" Male Tube Adaptor (must be ordered separately) 6 02-12695 '4" Tube x 'A" JIC Adaptor (must be ordered separately) 7 02-12696 ¼" Tube Elbow-90° (must be ordered separately) 8 02-12697 'A" Tube Coupler (not shown) (must be ordered separately) NOTE: The Actuation Hose required to connect the first container w/ IVO to the Actuation Tubing must be ordered separately. 4 Fike Control Panel Distance will vary depending on 14" x 0.035 wall Stainless container size; cut W tubing to fit I IRM Assembly Steel Tubing 1 2 (see note) 6 ,4, 4 IF 7 Adaptor I 1 Nipple w/ 'A" NPT Discharge Plug 2 Pressure Switch - • IF 1 ! r--- C. PIPO - IVPO IVO The illustration above shows the items required to make the proper connection between the container equipped w/ an IVO and the container(s) equipped w/ an IVPO. The maximum length of pneumatic actuation line (including hoses) cannot exceed 50 ft. (15.2 m) and up to 6 containers equipped w/ an IVPO. First remove the 'A" NPT Plug from Adaptor Nipple, and then install Actuation System as shown above. Secure Actuation tubing to a solid surface. Anchoring into plaster, sheetrock wall or any other facing material is NOT acceptable. The Discharge Pressure Switch (p/n 02-12534) is required and is wired to the manual release contact in SHP PRO or to a monitor module in Cheetah Xi or Xi50. For additional information regarding the installation and resetting of the IVPO, refer to manuals 06-431 and 06-433. 5 of 6 RESET INSTRUCTIONS Remove IVO from Impulse Valve by removing Retaining Clip. I1 Remove Safety Pin and pull the red Manual Strike Button knob until i 4 IVO the internal latch resets (identified by audible click) Tr Pin Extended (IVO - Fired Position) No L. Pull Knob - . I ________ Safety Pin Insert IVO into Reset Tool and secure with Retaining Clip - Reset Tool L. - .) 4 Retaining Clip Insert and secure the Safety Pin, push Reset Tool button (firmly) against a hard surface until IVO Pin resets (clicks into place) Hard Surface Reset Tool Retaining Clip Remove Retaining Clip and Reset Tool, IVO is reset and ready to be installed on Impulse Valve. IMPORTANT NOTE: Check IVO to ensure device is armed before inserting on Impulse Valve. I_I No Pin Exposed (IVO—Armed Position) . • 1 Copyright © Fike Corporation All Rights Reserved. Form No. IV.1.09.01-2, February, 2016. Specifications are subject changes without notice. Safety Pin 6 of 6 APPROVALS UL Listed -S3217 FM Approved Cheetah® Xi Cheetah® Xi 50 SHP PRO® CSFM -pending MEA- pending APPROVED IMPULSE RELEASE MODULE DESCRIPTION The Impulse Releasing Module (P/N 10-2748) provides the primary interface between the supervised releasing circuit(s) of a Fike fire suppression system and the Impulse Valve Operator (IVO); which is used to release the fire suppressant agent from an impulse valve container. The IRM is equipped with three capacitors that receive a constant charging current from the releasing circuit of the control panel. When fully charged, the module is capable of firing a single IVO. Upon circuit activation, the output circuit reverses its output voltage polarity, causing the energy in the capacitors to be released to the Impulse Valve Operator. Each IRM is equipped with a red LED to provide positive indication that the module is in the active (release) state. Note: The IRM is provided as part of the IVO Kit (P/N 70-279) and does nor need be ordered separately if ordering the kit. SPECIFICATIONS Current Consumption: +24V Supervisory: 20.0 ma (during capacitor charging) 3.0 ma (after capacitor is charged) -24V Activated: -37.0 ma (LED active) Temperature: 32 to 130°F (0 to 54.4°C), 93% maximum humidity Module Wiring: Control panel to IRM connections are supervised and power-limited Impulse Valve Operator (IVO) connection is non-supervised and power-limited Compatible Actuation Devices: 02-12728, Impulse Valve Operator (IVO) Compatible Releasing Panels: SHP PRO®, Cheetah® Xi, Cheetah® Xi 50 (Note: A maximum of six IRM's, wired in parallel, can be connected to each panel's releasing circuit.) INSTALLATION Each Clean Agent container shall be provided with a Fike P/N 10-2748 Impulse Release Module (IRM). The IRM shall be located at each container and shall be securely mounted in a standard 4" square x 2-1/8" deep UL Listed electrical box. Install conduit and releasing circuit wiring in accordance with the project drawings and appropriate wiring diagrams. All wiring must conform to the requirements of NFPA 70- National Electric Code, NFPA 72 - National Fire Alarm Code, NFPA 2001 - Standard on Clean Agent Fire Extinguishing Systems, and the requirements of the Local Authority Having Jurisdiction. 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 0 www.tike.com WIRING DIAGRAMS FROM RELEASING RELEASING PANEL OR MODULE pp 1 IVO CIRCUIT EOL 1eDeecDe]Pl eweewe P1 =0=000 +- IVO - + + - IVQ - + IRM TERMINAL IRM TERMINAL BLOCK BLOCK CLASS B (STYLE Y) WIRING TO RELEASING PANEL OR MODULE FROM RELEASING PANEL OR MODULE (+) P1 +- IVO - + IRM TERMINAL IRM TERMINAL BLOCK BLOCK CLASS A (STYLE Z) WIRING Copyright © Fike Corporation All Rights Reserved. 2 of 2 Form No. V.1.15.01-1, December 2010. Specifications are subject to change without notice. [fl DATA SHEET PIPES AND FITTINGS DESCRIPTION Pipe and fittings used in Clean Agent System piping network must conform to the requirements as outlined in NFPA 2001, latest edition. PIPING MATERIALS Piping materials must conform to the requirements as outlined in NFPA 2001, latest edition. The thickness of the piping wall shall be calculated in accordance with ASME B31.1 Power Piping Code. For Fike Clean Agent System, w/ 360 psig (24.8 BARG) working pressure, use a minimum piping design pressure of 500 psig (34.4 BARG) at 70°F (21°C). Caution: Cast iron pipe, steel pipe conforming to ASTMA120, or nonmetallic pipe SHALL NOT be used. The following piping materials and configurations are acceptable: Schedule 40 Threaded, Welded & Grooved Schedule 80 Threaded & Welded The following piping types and grades are acceptable for pipe configurations utilizing threaded, welded or grooved end connections Pipe Schedule NPS Pipe Size Wall Thickness Grade /Type A406C A-53B A-106B A-63B A-53A A-106A A-53A A-53F Seamless Seamless ERIN Seamless ERW Furnace 3/8 0.091 ,,,VO V V,' 1/2 0.109 3/4 0.113 1 0.133 11/4 0.140 ,.' ,,VO , 40 11/2 0.145 2 0.154 21/2 0.203 3 0.216 4 0.237 6 0.280 FITTING MATERIALS Fitting materials MUST conform to the requirements outlined in NFPA 2001, latest edition. Fitting Size Fitting Class Up to 3" NPT Class 300 malleable or ductile iron Over 3" NPT 1000 lb. ductile or forged steel All pipe sizes Class 300 flanged Note: All grooved fittings must be UL Listed and conform to the pressure requirements outlined in NFPA 2001, latest edition. Cast Iron fittings are NOT acceptable. Form No IV 1 19 01 704 SW 10th Street e P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A Phone: 8162293405 0 www.fike.com PIPE SIZE CHANGE Pipe size changes, to increase or decrease the size, can be done at three different locations in the piping network: When the change in pipe size is done at a tee, this is accomplished by using either a Pipe Size Change at a Tee reducing tee or a standard tee and reducing fittings. All reducers must be concentric bell reducers or concentric reducing couplings. When the change in pipe size is done at an elbow, this is accomplished by using either Pipe Size Change at an Elbow reducing elbows or a standard elbow with concentric bell reducers or concentric reducing couplings. Pipe Size Change at a Coupling When the change in pipe size accomplished at a coupling, only concentric bell reducers or concentric reducing couplings can be used. Note: Reducing bushings, weld-a-let, and hole-cut fittings ARE NOT acceptable. INSTALLATION The piping system should be securely supported with due allowance for agent thrust forces, thermal expansion, and contraction, and should not be subject to mechanical, chemical, vibration, or other type of damage. The maximum horizontal spacing for screwed, welded or grooved pipe are as indicated on the following table: Pipe Size (IN) Distance Between Supports (feet) Rod Diameter (IN) 3/8 7 3/8 1/2 7 3/8 3/4 7 3/8 1 7 3/8 11/4 7 3/8 11/2 9 3/8 2 10 3/8 21/2 11 1/2 3 12 1/2 4 14 5/8 6 17 3/4 Notes: Each pipe section shall be cleaned internally before installation with a nonflammable cleaner such as Perchlorethylene in accordance with NFPA 2001, latest edition. Teflon tape or joint compound shall be used on all threaded joints. All grooved coupling gaskets shall be lubricated per the manufacturer's specifications. "C" Clamps are not acceptable to support rod hangers. Rigid pipe supports are required to support the "live load" of the pipe system during discharge. Rigid bracing is required at each directional change, fitting, tee and nozzle. All drops to 180 nozzles require back bracing in the opposite direction of the discharge. Earthquake bracing shall be used where required by local code. (Refer to ANSI B31.1 Power Piping Code for additional information) For additional information on pressure rating of pipe and fittings, plus recommended pipe supports and hangers, refer to FSSA's Pipe Design Handbook, FSSA PDH-01. All system piping shall be installed in Strict accordance to system plans. If piping changes are necessary, they must be recalculated on Fike's Flaw Calculation Program. CONNECTION - CONTAINER TO PIPING NETWORK The container discharge valve outlet is connected to the piping network using the following items: Discharge Valve Size Fittings Required Comments 1" Discharge Valve 1" Victaulic Coupling (P/N 02-9964) supplied w/ Container (5, 10, 20, 35, 60 & 100 lb.) 1" Adapter Nipple (p/n 70-2164) x 4.75" (121 mm) 1g. 1" coupling or Union (not shown) Supplied by Others 3" Victaulic Coupling (P/N 02-1987) Supplied w/ container (150,_150i, 215, 375, 650 & 1000) 3" Discharge Valve 3" Adapter Nipple (P/N 70-2163) NPT to Victaulic x 4" (114 mm) 1g. Standard Item - Supplied w/ Container (150, 150i, 215, 375, 650 & 1000) 3" Adapter Nipple (P/N 70-2175) Victaulic to Victaulic x 4" (114 mm) 1g. (not shown) Optional Item 3" Coupling or Union (not shown) Supplied by Others Notes: It is not necessary to supply a pipe union after the grooved coupling to facilitate removal of the container forservice or maintenance purposes. The container can be removed by removing the grooved coupling provided with each container. Adapter Nipple is supplied with 1/4" NPT female threads (plugged) to connect to: Discharge Pressure Switch Used to provide pressure to activate IVO (slave) container(s) 2 of 3 Important Note: Remove the Raffle Plate located inside the grooved coupling before connecting the discharge piping to the container. The Raffle Plate is an anti-recoil device that must be installed whenever transporting or handling pressurized containers that are not connected to the discharge piping. - Connected to Discharge Piping - by using a Coupling or Union (See Note 1) - Adapter Nipple w/ SI" female threads (see Note 2) Victaulic Coupling - - - Discharge Outlet - Impulse Valve N Front View Copyright © Fike Corporaticn All Rights Reserved. 3 of 3 Form No. iV.1.19.01, August 2012. Specifications are subject to change without notice. & L EI MOUNTING STRAPS AND BRACKETS DESCRIPTION Mounting Straps / Brackets are used to secure containers to a wall or other suitable mounting surface. These devices are supplied with each container purchased in accordance with the information shown below. Mounting hardware is supplied by system installer. Caution: Anchoring into plaster, she etrock wa//or any other facing material is NOT acceptable. SPECIFICATIONS Material: Carbon Steel Bracket Color: White (standard)/Red (see note below) Container Size lb. (1) Bracket P/N 5 (2) 70-2135-X 10(4) 70-2135-X 20(8.5) 70-1372-X 35 (15) 70-1372-X 60 (27) 70-1070-X 100(44) 70-1345-X 150 (61) 70-2141-X 150/ (61) 70-2142-X 215 (88) 70-1310-X 375 (153) 70-1310-X 650(267) 70-1384-X 1000 (423) 70-1384-X Nate: Container brackets have 2 paint options (White or Red). When ordering a container bracket the paint option must be specified. For a bracket pointed white enter port number - Wand for bracket painted red enter part number - R. Example: 20 lb. container bracket painted white, the part number is 70-1372-W TflLi11FF1 I....f :.:T. APPROVALS: UL Listed ULC Listed FM Approved LISTED APPROVED 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.f/ke.com nting Strap P1000 Unistrut Channel (by Others) Wall Unistrut Nut, Bolt & Washer (by Others) MOUNTING DETAILS —100, 215, 375, 650 & 1000 LB. (44, 88, 153, 267, 423 1) CONTAINERS P/N Container Size Dimension Mounting Position A IN (mm) BIN (mm) 70-266 100 lb (44L) 20.00 (508) 12.25 (311) upright (Valve Up) 70-268 215 lb (88L) 11.00 (279) 21.75 (552) upright (Valve Up) 70-269 375 lb (153L) 24.00(610) 21.7S(552) Upright (Valve Up) 70-270 650 lb (267L) 28.00 (711) 26.00)661) Upright (Valve Up) 70-271 1000 lb (423L) 40.00 (1016) 26.00 (661) Upright (Valve Up) Notes: All dimensions are approximate Mounting Strap can be fastened to the Unistrut Channel with a Unistrut Spring Nut and Bolt. Copyright © Fike Corporation All Rights Reserved. 6 of 6 Form No. V.1.18.01, August 2012. Specifications are subject to change without notice. F i ke Fike Clean Agent System Flow Calculation Software (HFC-227ea) UL: EX4623 / Component of FM Approved System System calculated within limits of Fikes UL listing and FM approval. FPS 1150 W. Central Ave. Suite D Brea, CA 92821 Phone: 714-257-2244 File Name: 2-A.FC4.FC4 Consolidated Report Customer Information Company Name: FPS Address: 1150 West Central Ave Suite D Brea, CA 92821 Phone: 714-257-2244 Contact: Title: Project Data Project Name: Viasat Designer: Tomas Obregon Number: Account: C3196 Location: Carlsbad, CA Description: System A' Enclosure Report Elevation: 0 ft (relative to sea level) Atmospheric Correction Factor: 1 (NFPA 2001) Enclosure 1 MDF Room Enclosure Temperature: Number of Nozzles: Calculation Date/Time: Wednesday, November 7, 2018, 7:37:22 AM Copyright (c) Jensen Hughes, Inc. Licensed to: Fike Corporation Key ID: 700420360 Page: 1 of 7 c'J Fike Consolidated Report Minimum: 70 F Width: 0.0 ft Maximum: 70 F Length: 0.0 ft Max. Concentration: 7.05% Height: 0.0 ft Design Concentration: Volume: 2618.0 ft Adjusted: 7.05% Non-permeable: 0.0 ft Minimum: 7.00% Total Volume: 2618.0ft 3 Mm. Agent Required: 89.3 lb Adjusted Agent Required: gjo lb Leakage Area vs Pressure Enclosure Pressure (psf) Agent Source Report Calculation Date/Time: Wednesday, November 7, 2018, 7:37:22 AM Copyright (c) Jensen Hughes, Inc. Licensed to: Fike Corporation Key ID: 700420360 Page: 2 of Fike Consolidated Report Agent: Cylinder Name: Cylinder Part Number: Agent Per Cylinder: Fill Density: Number of Main Cylinders: Number of Reserve Cylinders: Cylinder Empty Weight: Weight, All Cylinders + Agent: Floor Area Per Cylinder: Floor Loading Per Cylinder: HFC-227ea / Propellant N2 100 lb. Cylinder, Upright 70-266 90.0 lb 57.9 lbs / cubic ft 1 0 77.0 lb 167.0 lb 0.63 ft 2 265 lbs/ft 2 Calculation Date/Time: Wednesday, November 7, 2018, 7:37:22 AM Copyright (c) Jensen Hughes, Inc. Licensed to: Fike Corporation Key ID: 700420360 Page: 3 of 7 I Consolidated Report Parts Report Total Agent Required: 90.0 lb Cylinder Name: 100 lb. Cylinder, Upright (Part: 70-266) Number of Cylinders: 1 Nozzle Nozzle Type Diameter Nozzle Code El-Ni 180 NPT- Br 1 in 0 Nozzle Area Part Number 0.5400 in 2 80-101-2500 Pipe & Fittings Type Diameter Length Elbows )) Elbows (45) Tees Unions 40T 1 i 28.25 ft 3 0 0 0 Other Objects Name Quantity Part Number System Acceptance Report System Discharge Time: 9.3 seconds Percent Agent In Pipe: 16.5% Percent Agent Before First Tee: 0.0% Enclosure Number: 1 Enclosure Name: MDF Room Minimum Design Concentration: 7.00% Adiusted Design Concentration: 7.05% Predicted Concentration: 7.05% Maximum Expected Agent Concentration: 7.05% (At 70 F) Calculation Date/Time: Wednesday, November 7, 2018, 7:37:22 AM Copyright (c) Jensen Hughes, Inc. Licensed to: Fike Corporation Key ID: 700420360 Page: 4 of Fike Consolidated Report Minimum Adjusted Agent Agent Nozzle Required Required El-Ni 89.3 lb 90.0 lb Predicted Average Agent Nozzle Delivered Pressure 90.0 lb 119 psig Calculation Date/Time: Wednesday, November 7, 2018, 7:37:22 AM Copyright (c) Jensen Hughes, Inc. Licensed to: Fike Corporation Key ID: 700420360 Page: 5 of Fike Consolidated Report Pipe Network Report Total Total Pipe Start End Pipe Pipe Pipe Elevation Equivalent Nozzle Nozzle Nozzle Nozzle Description Section Node Node Type Diameter Length Union Change Length Name Size Type Area Cylinder - On Man./End 0 2 1 in 3.23 ft 0 3.23 ft 6.00 ft Pipe System 2 3 401 1 in 10.50 ft 0 10.50 ft 10.50 ft Elbow (90) System 3 4 40T 1 in 0 2.80 ft Pipe System 4 5 40T 1 in 14.00 ft 0 14.00 ft Elbow (90) System 5 6 40T 1 in 0 2.80 ft Pipe System 6 7 40T 1 in ISO ft 0 3.50 ft Elbow (90) System 7 8 40T 1 in 0 2.80 ft Pipe&Nozzle System 8 9 40T 1 in 0 25 ft 0 0 25 ft 0 30 ft El Nl 1 in 180 NPT Br .0 .5400 in 2 Key ID: 700420360 Page: 6 of 7 Fike Consolidated Report View #: I Isometric View-Node Key ID: 700420360 Page: 7of7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0900:0137 Page 1 of 3 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Fike Protection Systems704 South 10th St., Blue Springs, MO 64024 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Model CyberCat 1016 or 254 control unit, part no. 10-064-c-p-d or 10-066-c-p-d (c: R=Red or B=Black; p: 1=120V or 2=240V; d: B=Blank or L=Lexan) and Model Cybercat 50 Control Unit Part No. 10-070-c-p (-d) (c: R = Red or = Black; p: 1 = 120V or = 240V; d: d = Dead Front, Blank = no Dead Front) fully addressable fire alarm control panels. Base configuration includes the main board, enclosure and a transformer. Models 1016, 254 and 50 are suitable for critical process management and voice evacuation via Fike Guard model FGX-MP/DP. Suitable for local, auxiliary, remote and central station services. Also suitable for proprietary PPU and proprietary receiving station when used with Model 10-2627 or 10-074. Refer to listee's data sheet for detailed product description and operational considerations. System components: 10-2472, -2525; 1016, 254 10-2620; 50 Point Controller 10-2473; Supplemental Loop Module 10-2474; Supplemental Power Supply 10-2204; CRM4 Relay Module 10-2254; Reverse Polarity Module 10-1832; Agent Releasing Module Ill 10-2482; Network Card FGX-MP/DP; Voice Evacuation System 24-001 thru 24-012; Master Panel Voice Evacuation System 24-013 thru 24-024; Distribution Panel Voice Evacuation System 24-025; Fire Phone Jack S.G. Plate 24-026; Fire Phone Handset 24-027; Fire Phone Handset Cabinet 24-028; Fire Phone Station Surface Mount 24-038; Fire Phone Interface 24-039; Fire Phone Output 10-2483-C-L; Cybercat 1016 Enclosure with Lexan 10-2483-C-L-0; Cybercat 1016 Enclosure with Lexan Solid Dead Front 10-2483-C-L-3; Cybercat 1016 Enclosure with Lexan 3 Module Slot 10-2483-C-L-13; Cybercat 1016 Enclosure with Lexan 13 Module Slot 10-2527-C-L; Cybercat 254 Enclosure with Lexan 10-2527-C-L-0; Cybercat 254 Enclosure with Lexan Solid Dead Front *Revision 02-23-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0900:0137 Page 2 of 3 10-2527-C-L-3; Cybercat 254 Enclosure with Lexan 3 Module Slot 10-2527-C-L-13; Cybercat 254 Enclosure with Lexan 13 Module Slot 10-2528; Point ID Digital Alarm Communicator Transmitter (DACT), 10-2621-C; Cybercat 50 Enclosure 10-2476; DACT 10-2321; Remote Display 10-11 x; LED Display Graphic 10-2413; Masterbox Supervision Module 10-2360; Series Impedance 10-2373; Zone Annunciator 55-042; Control Module 10-2630, -2631, -2646; Remote Display 10-2583, -064; Multi-Interface Module 10-2627, -074; Ethernet Module 10-2624; Fiber Optic Network Card 10-2658; 6 Zone Smoke Control Module 10-2659; Input/Output Module 10-2660; Zone Annunciator 10-2667; Remote 20 Zone Annunciator 10-2663; Smoke Control Graphic 10-2588-B, -2589B, -2590V-B, 10-2590H-B, -2591V-B, 10-2591H-B; FSCS Enclosure Back Boxes 10-2690-B, -2691-B, -2692V-B, 10-2592H-B, -2693V-B, 10-2693H-B; FSCS Enclosure Doors 10-2726; Amplifier Card 10-2746; Class A Speaker Card 10-2727; Digital Paging Card 10-2741; Digital Paging Control Card 10-2661; Audio Control Card 10-2728; Fire-Phone Card 10-2730; Supplemental Fire-Phone Card 10-2483-C-L-19; Cybercat 1016 Enclosure with Lexan 19 Module Slot 10-2483-C-L-21; Cybercat 1016 Enclosure with Lexan 21 Module Slot 10-2527-C-L-19; Cybercat 254 Enclosure with Lexan 19 Module Slot 10-2527-C-L-21; Cybercat 254 Enclosure with Lexan 21 Module Slot 10-2771-C; FCC Enclosure 21 Card Dead Front 10-2772-C; FCC Enclosure 25 Card Dead Front 10-2753-C; Retrofit Enclosure 10-2754-C; Remote Audio Enclosure (3AMP) 10-2755-C; Remote Audio Enclosure (SAMP) 10-2756-X; Fire-Phone Housing 10-2757-X; Microphone Housing 24-131; Emergency Telephone Cabinet 24-132; Fire Fighter Phone Cabinet (5) 24-139; Fire Fighter Phone Cabinet (10) 24-133; Fire Fighter Phone Jack *Revision 02-23-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0900:0137 Page 3 of 3 24-134; Portable Handset 24-135; Addressable Fire-Phone Module+9 10-2797; Remote Audio Enclosure (lAMP) 10-2794-X; Remote Display Enclosure 10-2793-X; Local Operating Console Enclosure 10-2796-X; Local Operating Console wlRemote Display Unit Enclosure 10-2798; LOC Paging Control Card 10-2814; LOC Remote Paging Assembly 10-2816; LOC Digital Paging Card 10-2813; LOC Microphone Housing 10-2800; LOC Microphone Enclosure 10-2801; LOC Microphone Enclosure with 10-Button Remote Display 10-2802; Remote Display Three Card 10-2792; Class A Peripheral Bus Card 10-2818; Class A Peripheral Bus Card Assembly 10-2831; Audio Adjunct Panel (AAP1) 10-2832; Audio Adjunct Panel (AAP3) *102946 *68517: High Level Interface Assembly INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. Also suitable for high-rise applications, emergency voice evacuation and in-building mass notification. Refer to listee's Installation Instructions Manual for details. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 1999 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds or less. 2. Combined with 7170-0900:148 Revision 02-23-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division kTfiIThTI CYBERCAT® 50 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike's CyberCat 50 (P/N 10-070) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system It is ideal for all life safety and property protection applications and is intended for both commercial and industrial use. It is designed with extensive programmability that allows the almost- instantaneous relay of information and the ability to perform process management tasks with ease including HVAC shutdowns, Emergency Voice Evacuation, damper control, door closure, elevator recall, security, and CCTV/Building Management Awareness. This cost-effective panel comes standard with one Signaling Line Circuit (SLC) that supports 50 devices, with any mix and match of sensors and modules. The CyberCat 50 utilizes extreme intelligence via its Eclipse® based sensors including photoelectric, photoelectric with heat, ionization, photoelectric duct, and heat detectors. It also utilizes Eclipse based modules such as the monitor, mini-monitor, relay, intelligent pull station and control modules. With CyberCat 50, every device communicates as a peer on the signaling line circuit. These peers not only communicate up-to-the-second information to the control panel, but also communicate with each other. Each device is capable of generating accurate and highly detailed information Conventional fire alarm systems give a general idea of the fire's location, while the CyberCat 50 intelligent sensors indicate precisely which device is in an alarm state. This intelligence provides incredible speed with response times as little as one-quarter second between manual pull station and notification appliance. Its flexibility allows you to attach the intelligent devices that are required for your specific application. Fike CyberCat 50 The System is programmed with either the Windows based field configuration software C-LlNX' or through a comprehensive password protected front-panel keypad programming options. This option allows you to APPROVALS: quickly update and adapt to any future requirements or changes in the system such as changes in occupancy or remodeling. The sophisticated control panel circuitry coupled with the software allows you to read UL - S2203 specific information and sensitivity levels of the different Eclipse devices. The sensors also compensate for FM - 3029134 any changes due to age, contamination, or other environmental factors. City of Denver o CSFM - 7165-0900:137 SYSTEM OPERATION MEA - 490-04-E, Vol. 2 The CyberCat 50 Control system operates on a "Zone and State" relationship. In this design, all input and output devices must be assigned to at least one zone or to all zones (254 are available), each one defining an area to be protected. Input devices can be assigned up to 253 zones (one zone is typical) and output devices may be assigned up to 254 zones. Ui. These devices use the SLC signaling line circuit to exchange status information with other devices as well APPROVED as with the control panel. When an input is activated, it is configured to cause its associated zone to enter into an operational state. Any detection device will cause its associated zone to enter into an alarm state. The output devices are configured to activate to protect and evaluate the endangered zone. This system is completely modular, allowing you the flexibility to design a system that is just right for your application. A typical configuration is shown on page 2 that illustrates the communications of a CyberCat 50 system. - V1 Form Form No D.1.15.01-2. 704 SW 10th Street • P.O. Box 610 R Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 www.tike.com CON FIC ION I Cont icti f,due Cyber, Fire ALortn Panel TYPICAL CONFIGURATION AIR \PL vFcr!A LaaerPluc Ul'1An lItAT DETECTION OAt3Lt :: fl1zL EOdolL on:torModute STANDARD FEATURES SØrirI ,o #cths Or Dokfls Systsrm GENERAL WING FIRE AIJcRM Photo Ion Photo Heat Intelligent 14 Pull Station L1 - Strobe NAC ModUle yModtle Tams oi and operates Performs Process Management Tasks r.tw055, ho,na, bo s Shutdowns /ete P,eoatiat' 5ycterrts Allows or noftipto C/AC Sec ity/CC portent to, dt00000; pievators ,aorrurrtAwareorsr starts at atrt,,o Doors Dontrers The Cybercat features are designed to save lives and protect your valuable capital investments through unprecedented speed, intelligence and flexibility. These features include: All Cybercat panels come standard with a controller, transformer and enclosure (see ordering information for details) 254 user defined zones 80 character, backlit LCD display Real time clock 3200 event history buffer Critical process monitoring One-person walktest capability Disable by circuit, zone or device Drill function at panel and remote Provides solenoid releasing operation Alarm verification capability Easy to add/remove devices Diagnostic menus Local piezo with distinct event tones 10 Status LEDs to easily identify system status Built-in point ID DACT Module Supports up to 31 peripheral devices such as Remote Display, LED Graphic, Zone Annunciators, Ethernet Modules and Multi-Interface Modules USB port for programming 2 of 6 CYBERCAT 50 CONTROLLER SPECIFICATIONS The controller contains the power supply, microprocessor, hardware interface, display and keypad. Enclosure Steel Enclosure 22.5" H x 14.5" W x 3.25" D (Back-box dimensions) Flush or surface mounting Removable door for ease of installation Available in red or black Dead Front option available to isolate panel's internal electronics and wiring Power 5.25 amps useable alarm power Operation from 120VAC/60 Hz or 240 VAC/50 Hz transformer Two 24V DC, 1.75A continuous auxiliary power outputs Supports up to 75AH of batteries Controller consumes 0.116A @ 24VDC in normal standby mode and 0.176 @ 24 VDC in alarm Signaling Line Circuit Address devices with Infrared (IR) tool, similar to remote control device One SLC loop, NFPA style 4, 6 or 7 50 devices, any mix and match of sensors and modules True peer-to-peer digital protocol for extremely fast and reliable communications Auto address function Automatic day/night sensitivity adjustment Automatic holiday sensitivity adjustment Acclimate operation for sensors IR Tool provides ability to read sensitivity levels or perform remote test of device Devices contain multi-color LED for quick reference of device status Sensors provide early warning pre-alarm detection and can also provide a summing feature (up to eight sensors) Maximum Resistance: 70 ohms Maximum Capacitance: .60 pf 12,000 ft. maximum distance total from panel to last device. NAC Circuit Two NAC circuits standard Rated at 24VDC, 1.75 Amps maximum Class A or B Built-in synch protocol for System Sensors and Gentexl devices Operating Environment 32- 120°F (0- 49°C) 93% relative humidity, non-condensing OPTIONAL MODULES AND PERIPHERAL DEVICES Point ID Dact (Digital Alarm Communicator Transmitter) Module (P/N 102528)* The DACT provides interface with Central Station monitoring systems. It is available with 5 contact zones of connection OR the intelligent serial interface which provides point ID information. The Contact ID form is the preferred reporting format. It provides a four digit account code followed by a three digit event code, a two-digit group number, and a three digit contact number, all of which are used to provide specific point identification. This DACT can also provide an SlA or 4/2 Pulse reporting format. Note: 10-2476 is same as 10-2528 with enclosure for external mounting. 14 Button Remote Display Unit ( P/N 102646)* The Fike fourteen button remote display (FRD), provides remote annunciation of Fike's intelligent control panels. The FRD is provided with a 80 character, backlit display which performs two display functions. First, it duplicates information provided by the control panel. Additionally the FRD has the capability of viewing system conditions such as alarm, trouble, supervisory, etc. The FRD also includes six keys (Enter, Escape, +/-, left/right arrow) that are used for navigation through events as well as configuration of the device. Additionally it has eight programmable buttons that can be configured for things such as reset, silence, acknowledge, drill, or process. A key lock is included for additional security access. 10 Button Remote Display Unit (P/N 102631)* The like ten button remote display (FRD), provides remote annunciation of like's intelligent control panels. The FRD is provided with a 80 character, backlit display which performs two display functions. First, it duplicates information provide d by the control panel. Additionally the FRD has the capability of viewing system conditions such as alarm, trouble, supervisory, etc. The FRD also includes six keys (Enter, Escape, +/-, left/right arrow) that are used for navigation through events as well as configuration of the device. Additionally it has four dedicated buttons that perform the following functions: drill, silence, acknowledge, and reset. A key lock is included for additional security access. 2 Button Remote Display Unit (P/N 102630)* The like two button remote display (FRD), provides remote annunciation of Fike's intelligent control panels. The FRD is provided with an 80 character, backlit display which performs two display functions. First, it duplicates information provided on the main control panel. Additionally, the FRD has the capability of viewing system conditions such as alarm, trouble, supervisory, etc. Fike Zone Annunciator (P/N 102667)* The like twenty zone remote annunciator is used with Fike's intelligent control systems to provide remote annunciation for up to twenty zones at a location remote from the control panel. The module provides a tabular display that incorporates 20 red alarm and 20 yellow trouble/supervisory LEDs. Each LED is programmable and can provide visual indication of alarm, trouble/supervisory conditions for zones or individual points. Communication between the intelligent control panels and remote annunciator is via the R5485 peripheral bus. When an event from the control panel is received the appropriate LED will illuminate based on the annunciator's configuration. * See ordering inform ation for individual data sheet that gives additional specifications 3 of 6 Fike Ethernet Module (P/N 102627)* This Module provides the ability to remote monitoring of multiple CyberCat panels via Ethernet/lP. This module is connected to the CyberCat via the peripheral connections at P6 and will be configured as a peripheral device. In order to utilize the remote monitoring capability, a network ID must be assigned to each panel for identification purposes. This module connects to the Panel at P6 per ± and also requires 24 volts DC from the panel to P6 24A ±. See the 06-388 Ethernet Module manual for more details. Fike Multi-Interface (P/N 102583)* The primary function of the multi-interface module is that it is used as a printer interface for the CyberCat control panels. It provides specific event and point information to be communicated from the panel to the printer. It is compatible with either a Epson FX-890 or equivalent IEEE 1284 standard printer or for UL required applications the Keltron 90 series UL listed fire alarm printer. PROGRAMMING CONFIGURATION Software All configuration variables can be assigned using C-LINX software. This software provides the designer the capability to provide a pre- engineered design. The user can review the construction plans to assign the zones. The configuration can also be set to identify the exact device circuit operation desired along with the custom message information. IR Configuration Tool (P/N 55051)* This optional hand-held infrared remote control is available on the CyberCat system. This small device can be used in the field to simplify installation, testing and service. It operates with 2 AA batteries and can read device information such as loop, address, branch and service dates and initiate device test. This tool: Communicates bi-directionally with any CyberCat device Easily addresses devices by setting the loop and address Quickly reads sensitivity levels, date serviced, device type, loop and address, manufacture date Immediately records the date serviced Instantly initiates walk test of any sensor or module Accesses and tests hard-to-reach sensor or module (such as duct detector) through any other device on loop FIELD WIRING DIAGRAM COMMUNICATION TO REMOTE PANELS LOCATED OFF PREMISIS SYSTEM INTERNE PRINTER I-I LED I I ETHERNET MULTI- GRAPHIC MODULE INTERFACE MASTERBOX TELCO LINES INTERNAL OR EXTERNAL R5485 DACT RS485 PERIPHERAL REMOTE ZONE BUS (31 MAX.) DISPLAYS ANNUNCIATO RS232 24V-DC AUX POWER (CONTINUOUS) 24V-DC AUX POWER IF— (CONTINUOUS) '/ESDA DETECTOR ONBOARD RELAYS (ALM, TEE. SUPV) UP TO 253 PROGRAMMABLE ZONES F=_ I LAPTOP PC 120/240 VAC DEDICATED - POWER INPUT COMPATIBLE DETECTORS SUPERVISED NAC CIRCUIT 41 MASTERBOX DMM SUPERVISOR MM MODULE APS CZM MMM SCM RM TFIRE ONAc/ONTRDL IDC SOLENOID COMPATIBLE CONVENTIONAL DETECTORS SUPERVISED NAC CIRCUIT #2 CYSERCAT 50 ___________ EXTERNAL __ BATTERIES * See ordering information for individual data sheet that gives additional specifications 4 of 6 ORDERING INFORMATION Fike P/N Description Individual Datasheet # 10-070-c-p or 10-070-c-p-d CyberCat 50 System, includes Controller, Enclosure, and Transformer C: (R=Red, B=Black) p: (1=120V, 2= 240V) d=Deadfront D.1.09.01 10-2620 CyberCat 50 System Controller (included and _with _10-066-c-p_ _—L) D.1.09.1 10-2519-c Dead Front Option C: (R=Red, B=Black) 10-2528 Point ID DACT (Included with CyberCat 50 systems above) D.1.18.01 Peripheral Devices 10-2630 2 Button Expanded Protocol Remote Display P.1.103.01 10-2631 10 Button Expanded Protocol Remote Display P.1.107.01 10-2646 14 Button Expanded Protocol Remote Display P.1.108.01 10-2667 Zone Annunciator P.1.118.01 10-2627 Ethernet Module D.1.22.01 10-2583 Multi-Interface Module P.1.85.01 Intelligent Sensors 63-1052 Photoelectric Smoke Sensor Non-Isolator Version P.1.88.01 63-1058 Photoelectric Smoke Sensor Isolator Version P.1.88.01 63-1053 Photo/Heat Combination Sensor Non-Isolator Version P.1.89.01 63-1059 Photo/Heat Combination Sensor Isolator Version P.1.89.01 60-1039 Thermal Sensor Non-Isolator Version P.1.90.01 60-1040 Thermal Sensor Isolator Version P.1.90.01 67-033 Ion Sensor Non-Isolator Version P.1.91.01 67-034 Ion Sensor Isolator Version P.1.91.01 63-1057 Duct Sensor Non-Isolator Version P.106.01 63-1062 Duct Sensor Isolator Version P.106.01 63-1056 Duct Housing P.106.01 Intelligent Sensor Bases 63-1054 6" Sensor Base Non-Isolator Version R1.98.01 63-1060 6" Sensor Base Isolator Version P.1.98.01 63-1055 4" Sensor Base Non-Isolator Version P.1.99.01 63-1061 4" Sensor Base Isolator Version P.1.99.01 63-1064 Sounder Base P.101.01 63-1063 Relay Base P.101.01 5 of 6 Intelligent Modules 55-045 Mini-Monitor Module Non-Isolator Version P.193.01 55-050 Mini-Monitor Module Isolator Version P.1.93.01 55-041 4" Monitor Module Non-Isolator Version P.1.92.01 55-046 4" Monitor Module Isolator Version P.1.92.01 20-1063 Intelligent Pull Station Non-Isolator Version P.1.65.01 20-1064 Intelligent Pull Station Isolator Version P.1.65.01 55-042 Supervised Control Module Non-Isolator Version P.1.94.01 55-047 Supervised Control Module Isolator Version P.1.94.01 10-2360 Series Solenoid Diode/Resistor (Needed for solenoids) 10-2413 Masterbox Interface 55-043 Relay Module Non-Isolator Version P.1.95.01 55-048 Relay Module Isolator Version P.1.95.01 55-055 Zone Interface Module Non-Isolator Version P.1.114.01 55-060 Zone Interface Module Isolator Version P.1.114.01 55-056 Dual Monitor Module Non-Isolator Version P.1.115.01 55-061 Dual Monitor Module Isolator Version P.1.115.01 Programming Parts 55-051 Infrared (IR) Remote Control Tool P.1.97.01 06-327 C-LINX Software 10-2629 Interface cable, USB/A Male to USB/B Male 10-2477 DACT Programmer Copyright © Fike Corporation All Rights Reserved. 6 of 6 Form No. D.1.19.01-2, June 2009. Specifications are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 11 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0900:0152 Page 1 of 1 CATEGORY: 7270 - HEAT DETECTOR LISTEE: Fike Protection Systems704 South 10th St., Blue Springs, MO 64024 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Models 60-1039 and 60-1040 combination electronic fixed-temperature and rate-of-rise type heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical rating: 21.6 V Fixed Temperature Rating: 135- 155°F at 50 ft spacing 165-174°F atl5ftspacing 175- 190°F at 50 ft spacing INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/temperature rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 08-16-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division APPROVALS: UL-S2101 FM City of New York - 63-05-E CSFM - 7270-0900:0152 APPROVED Fike P/N Mfg. Model Description 60-1039 60-1039 Fixed Temperature/Rate-of-Rise Heat Detector - Non-isolator 60-1040 60-1040 Fixed Temperature/Rate-of-Rise Heat Detector - Isolator Mounting Bases 63-1054 EBF 6" Flanged Mounting Base - Non-Isolator 63-1055 EB 4° Flangeless Mounting Base - Non-Isolator 63-1060 EBFI 6" Flanged Mounting Base - Isolator 63-1061 EBI 4" Flangeless Mounting Base - Isolator 63-1063 EBR Relay Base 63-1064 EBS Sounder Base Accessories 20-1085 F110 Retrofit Flange 02-3868 RA100Z Remote LED Annunciator 20-1087 XR213 Detector Removal Tool 02-4986 XP-4 Extension for 20-1087 (5-15 ft) 20-1089 BCK-200B Black Detector Kit (10 pack) 55-051 EA-CT lR Tool [77 1flWi.1EET INTELLIGENT HEAT DETECTOR DESCRIPTION The Intelligent Heat Detector, P/N 60-1039 & 60-1040, is a fixed temperature/rate-of-rise detector that can be programmed for a discrete set-point within the range of 135-170°F for ordinary detection, or 175-190°F for intermediate detection. Detectors in the ordinary range may be programmed for either fixed temperature or 15°F rate-of-rise operation. Detectors in the ordinary range are programmed for fixed temperature only. The detector is designed with tn-color LEDs to indicate detector status. A remote LED annunciator, P/N 02-3868, is available as an accessory. It can be configured to follow the sensor LED operation or be independently controlled. The isolator version, P/N 60-1040, provides complete short circuit isolation for NFPA 72, Class X wiring if used with an isolator base. The detector is compatible with Fike's CyberCat® and Cheetah® Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the detector. This on-board intelligence allows each detector to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to be sent between the detector and the host control panel, resulting in faster, more reliable communication. SPECIFICATIONS Normal Operating Voltage: Standby Current: Alarm Current: Operating Humidity Range Installation Temperatures: Fixed Temperature Rating: Rate of Rise Detection: Spacing for Thermal Detectors: Height: Diameter: Weight: ORDERING INFORMATION 15 to 30 VDC 451 ItA max. @ 24 VDC (continuous broadcasts); 63-1039 451 VA max. @ 24 VDC (continuous broadcasts); 60-1040 2 mA max. @ 24 VDC (LEDs on) 10% to 93% Relative Humidity Non-condensing -4 to 100°F (-20 to 38°C); 135 - 174°F setpoint -4 to 150°F (-20 to 66°C); 175 - 190°F setpoint 135°F (57°C) to 190°F (88°C); programmable Responds to greater than 15°F/min.(8°C/min.); programmable Detectors set between 135 to 155oF or 175 to 1900F: 50 ft (15.24 m) spacing Detectors set between 160o to 1700F: 15 ft. (4.57 M) spacing 2.1 inches (51 mm)in 63-1054 base 6.1 inches (155 mm) installed in 63-1054 base 4.1 inches (104 mm) installed in 63-1055 base 4.8 ounces (137 g) 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 816-229-3405 • www.fike.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0900:0138 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Fike Protection Systems704 South 10th St., Blue Springs, MO 64024 Contact: Brent Mlika (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Models 63-1054, 63-1055, 63-1060, and 63-1061 detector bases. Each unit consists of resistors, capacitors, diodes, photo diodes and LED, mounted on a printed wiring board inside an enclosure which has an opening to the outside air. These devices are intended for installation on a vertical wall surface, ceiling or in a duct with a UL Listed Head. Refer to the listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible 63 Series smoke or heat detector heads and fire alarm control panels. Refer to listee's Installation Instruction Manual for details. XLF: 7300-1653:0178 *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division APPROVALS: UL-5911 FM City of New York - 9-05-E CSFM - 7300-0900:0138 APPROVED PLUG-IN DETECTOR BASE SIX INCH DESCRIPTION The Six Inch Detector Base, P/N 63-1054/63-1060, is designed for use with any of Fike's intelligent CyberCat®/Cheetah® Xi plug-in detectors. The base is approximately 2 inches (5.08 cm) larger than the detector head. The base mounts directly to a 3 'A inch and 4 inch octagon boxes, 4 inch square boxes (with or without plaster ring) and single gang boxes. The base provides terminals for connection of an optional remote LED annunciator, P/N 02-3868. The isolator version, P/N 63-1060, provides complete short circuit isolation for NFPA 72, Class X wiring. SPECIFICATIONS Diameter: 6.1" (155 mm); Wire Gauge: 12 to 18 AWG (0.9 to 3.25 mm2) ORDERING INFORMATION Fike P/N I Mfg. Model Description Mounting Bases 63-1054 EBF 6' Flangeless Mounting Base - Non-isolator 63-1060 EBFI 6" Flangeless Mounting Base - Isolator Accessories 20-1085 F110 Retrofit Flange 02-3868 RA100Z Remote LED Annunciator 20-1087 XR2B Detector Removal Tool 02-4986 XP-4 Extension for 20-1087 (5-15 ft) 20-1089 BCK-200B Black Detector Kit (10 pack) 55-051 1 EA-CT lR Tool Compatible Sensors 63-1052 63-1052 Photo - Non-isolator 63-1058 63-1058 Photo - Isolator 63-1053 63-1053 Photo/Heat - Non-isolator 63-1059 63-1059 Photo/Heat - Isolator 60-1039 60-1039 Heat - Non-isolator 60-1040 60-1040 Heat - Isolator 67-033 67-033 Ion - Non-Isolator 67-034 1 67-034 Ion - Isolator 7045W 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 0 www.fike.com TERMINAL LAYOUT TERMINAL DEFINITIONS No. Function Ti (+) SLC in/cut 63-1054, (+) SLC in only on 63-1060 T2 No Connection 63-1054, (+) SLC out 63-1060 T3 (-) SLC in/out, (-) Remote Annunciator T4 (+) Remote Annunciator Copyright © Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.98.01-3, March 2014. This document shall not be used for installation purposes. Please refer to installation instructions applicable for each product. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-2010:0101 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIKE CORPORATION704 South 10th Street; P.O. Box 610, P.O.Box 610, Blue Springs, MO 64013 Contact: Brent Mllka (816) 229-3405 Ext: 1220 Fax (816) 229-5082 Email: brent.mlika@fike.com DESIGN: Models 55-042 and 55-047 Supervised Control Module; Models 55-041 and 55-046 Monitor Module; Models 55-043 and 55-048 Relay Module; 55-045 and 55-050 Mini-Monitor Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 08-18-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 7TL1ThEI APPROVALS: UL-53705 FM City of New York - 8-05-E CSFM - 7300-2010:0101 APPROVED MONITOR MODULE DESCRIPTION The Monitor Module, P/N 55-041 & 55-046, provides a single, Class A or B initiating device circuit (lDC) capable of monitoring normally open contact fire alarm and supervisory devices or normally closed supervisory/process devices. In addition to monitoring the connected contacts, the module will monitor the wiring to the device for open circuits via an end of line resistor (Class B only). The module has a multi-color LED that will flash a unique color for instant status indication (Green for normal operation, Red for active input, Yellow for trouble at device). The isolator version of the module, P/N 55-046, provides complete short circuit isolation for installations requiring NFPA, Class X wiring. The module is compatible with Fike's CyberCat® and Cheetah® Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the module. This on-board intelligence allows each module to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to be sent between the module and the host control panel, resulting in faster, more reliable communication. SPECIFICATIONS Normal Operating Voltage: 15 to 30 VDC Standby Current: 4851iA max. (continuous broadcasts) IDC Voltage: 5.4 VDC max. Alarm Current: 2.0 mA (red LED on) Maximum IDC Wiring Resistance: 100 0 Temperature Range: 32 to 120°F (0 to 49°C) Humidity: 10 to 93% RH Noncondensing Dimensions: 4.17" H x 4.26" W x 1.22" D (106 mm H x 108 mm W x 31 mm D) Accessories: 39 k() End of Line Resistor (P/N 10-2625 included) Wall cover plate (included) 20-1072 Surface Mount Electrical Box 14 kO Short Detect Resistor, P/N 10-2530, must be ordered separately Mounting: Mounts on 4" square electrical boxes with 2 1/8" minimum depth For surface mounting, use 20-1347 surface mount box. ORDERING INFORMATION Fike P/N Mfg. Model Description 55-041 55-041 Monitor Module - Non-isolator 55-046 55-046 Monitor Module - Isolator Accessories 20-1346 CBB500 Control Module Barrier 20-1347 SMB500 Surface Mount Box 55-051 EA-CT IRTool 10-2625 39 kO End of Line resistor 10-2530 14 ko Short Detect resistor 13-0192 1 C58-004-000 I COVERPLATE 704 SW 10th Street • P.O. Box 610 ® Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 0 www.fike.com MODULE DIMENSIONS 1 .. 4.263 2.973 I MwrroR I 01 w 0 cII I&IIV 4.171 cCIi i®nil L[UiI k!i:jj- i Ii .00P l[___jl ADDRESS lc~) O9 1 2.735 I TERMINAL DEFINITIONS Ti (+) SLC in/out T6 No Connection T2 (-) SLC in/Out T7 (-) DC Class A/B Ti (+)SLC in/out TB lDC Class A/B T4 (-) SLC in/out T9 (+) IDC Class A TS No Connection TiD (-)I DC Class A Copyright © Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.92.01-6, March 2014. This document shall not be used for installation purposes. Please refer to installation instructions applicable for each product. APPROVED LL1 (T CONTROL MODULE DESCRIPTION The Control Module, P/N 55-042 & 55-047, provides a means to switch an external power supply to notification appliances or release solenoids used for sprinkler operation, or to activate Fike's Masterbox Interface module, P/N 10-2413, which is used on a Local Energy Type Auxiliary Fire Alarm System. The module is capable of Class A or Class B wiring. The device will monitor the wiring (while external power is not switched to the auxiliary devices) to the connected device for open and short circuits via an end of line resistor (Class B only). The module will monitor the external power input for loss of power (DC voltage supplies only). The isolator version of the module, P/N 55-047, provides complete short circuit isolation for installations requiring NFPA, Class X wiring. The module is compatible with Fike's CyberCat® and Cheetah® Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the module. This on-board intelligence allows each module to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to be sent between the module and the host control panel, resulting in faster, more reliable communication. SPECIFICATIONS APPROVALS: UL-52203 FM City of New York - 8-05-E CSFM - 7165-0900:0137 Normal Operating Voltage: Standby Current: Alarm Current: Maximum NAC Circuit Line Loss: Power Supply Monitor: Temperature Range: Humidity: Dimensions: Accessories: Mounting: OUTPUT RATING 15 to 30 VDC 630 uA max. average (continuous broadcasts) 2 mA (red LED on) 4VDC Regulated 24 VDC Trouble Range: 0 to 2 VDC 32 to 120F (0 to 49CC) 10 to 93% RH Non-condensing 4.675"H x 4.275"W x 1.4"D (119 mm H x 109 mm W x 36 mm D) 391<0 End of Line Resistor P/N 10-2625 (included) Wall cover plate (included) Surface Mount Electrical Box: P/N 20-1347 Control Module Barrier: P/N 20-1346 Series Solenoid Diode/Resistor: P/N 10-2360 Mounts directly on a 4-inch square electrical box with a minimum depth of 2 1/8 inches. For surface mounting, use 20-1347 surface mount box. Current Rating Maximum Voltage Load Description Application 2A 25 VAC PF=0.35 Non-Coded 3A 30 VDC Resistive Non-Coded 2A 30 VDC Resistive Coded 0.46A 30 VDC (L/R=20 ms) Non-Coded 0.7A 70.7 VAC PF=0.35 Non-Coded 0.9A 125 VDC Resistive Non-Coded 0.5A 125 VAC PF=0.75 Non-Coded 0.3A 125 VAC PF=0.35 Non-Coded Form No. P.1.94.01-4 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone: 8162293405 • www.fike.com © 0.937 2.735 1.158 ORDERING INFORMATION Fike P/N Description 55-042 Supervised Control Module - Non-isolator 55-047 Supervised Control Module - Isolator Accessories 20-1346 Control Module Barrier 20-1347 Surface Mount Box 55-051 IRTool 10-2360 Series Solenoid Diode/Resistor 10-2625 39K EOL 13-0192 COVERPLATE MODULE DIMENSIONS 4.263 2.973 I 4.171 U ... H ii 0.639 F- 2.985 TERMINAL DEFINITIONS Ti (i-) SIC in/out 18 (+) 24 VDC External Power in/Out T2 (-) SLC in/Out 19 (-) 24 VDC External Power in/out 13 (+) SIC in/out 110 (-s-) 24 VDC External Power in/out T4 (-) SIC in/out 111 NAC (i-) Class A/B T5 No Connection 112 NAC (-) Class A/B 16 No Connection 113 NAC (-) Class A 17 (-) 24 VDC External Power in/Out 114 NAC (+) Class A Copyright © Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.94.01-4, March 2014. This document shall not be used for installation purposes. Please refer to installation instructions applicable for each product. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFi, IFX/A and IFX/D enclosures. Models ACE-il, ACE-12 and ACE-13, *ACE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. V 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division W SIGNALING LISTED / SRD ACE-Il JLi'JWJ Standard Features: Installed with a 4 GB digital flash drive with USB B connector 2 key ring hooks to hold system keys Business card holder for key contacts Overall dimensions are 12" x 13" tall and 2 1/4" deep 18 gauge steel box and cover for security Durable powder coat baked on finish other colors available Standard 3/4" cat 30 key lock. Other lock assemblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" Legend sheet for documentation, passwords and system information SYSTEM RECORD DOCUMENTS The SRD is the perfect item to help you meet demanding code requirements today. NFPA 72 2013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD DOCUMENTS'." The SRD is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRD has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 72 2013 7.2.1). LiJLI7 NFPA j r REGISTERED / COMPANY EEoll : MOI13 Made ln\U.S.A. 508.485.0966 Local 508.4854740 Fax Space Age Electronics, Inc. 2013 ED0584 LT10641 Rev.A 1/2 No Excuses, Just Solutions! 0 'u /t 'SPACE AGE _L/ ELECTRONICS, INC. Specifications: The system record documents box (SRD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1 high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The SRD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface '. Requires Standard USB-B Connector Property Information tOn_________ Minimum Required Documentation(SIG-FUN) 1W 3 fl00009.un tv-ca touyuav-n...vuvao.aaro..,aca0005rn03 Certifications and Approvals a.ovmvoo-no.aocn.uocna3dla,o, 161 System InStollafion Concact6r 4tro.ecaammacaesocanna.ua.ansthccua.iaSe TOO__________ suucaourorn*ed,00uaojoudmvmadeoa0030vnootonoro 16.5 Authusiiy Having Jurindicton ______ C cony a a,.ynTo 000 opruous Equipment lntormasen .# tptos3o.EJ3n.I.un tacs0005snssl tde5yU.oeO,505 515.stt.I7fl on-o.Iy 11t0u44 Rm.t Legend sheet for storing system information - _-_--•------ including contacts, sign-off maintenance & -. test information, and alternate locations - - --- of additional records. Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description SSU00689 System Record Documents Cabinet RED SSU00690 Custom screening with your Logo EA0315 10 pack door legend sheet This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0584 LII 0641 Rev.A 2/2 Key Ring Hooks Business Card Holder Li LiL\ 11