HomeMy WebLinkAbout2815 JEFFERSON ST; ; AS060061; Permit9/14/22, 11:00 AM AS060061 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS060061 2815 JEFFERSON Job Address: Status: ISSUED ST Permit Type: SPRINK Applied 4/5/2006 Parcel No: 2031102900 Approved: 4/5/2006 Lot #: 0 Reference No.: Issued: 4/5/2006 PC #: Inspector: Project Title: KENT JESSE OFFICE BLDG FIRE SPRINKLER PLAN CHECK & INSPECTIONS FOR 5 SUITES Applicant: WESTERN FIRE PROTECTION 12232 THATCHER CT P0 WAY CA 858-513-4949 Owner: BICAJESSEE ADVENTURES L L C 2075 CORTE DEL NOGAL #S CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) L 575 0 575 0 about:blank 1/1 NM41011i,13 G LOBE® FIRE SPRINKLER CORPORATION QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm'frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick f ( \ Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response - a Sprinklers should be used advisedly and under the direction of approving -. - authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly QUICK RESPONSE is a hermetically sealed frangible glass ampule that contains a precisely RECESSED PENDENT measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed - temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. 1 TECHNICAL DATA See reverse side for Approvals and Specifications. - Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141-C). Water Working Pressure Rating - 175 Psi (12 Bars). QUICK RESPONSE Factory tested hydrostatically to 500 psi (34 Bars). RECESSED HORIZONTAL SIDEWALL Maximum low temperature glass bulb rating is -67°F (-55°C). Frame - bronze Deflector - brass Screw - brass Bulb seat - copper Spring - nickel alloy Seal - teflon Bulb - glass with alcohol based solution, 3mm size. Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER BULB I N.F.P.A. MAXIMUM I CLASSIFICATION I TEMPERATURES I COLOR I CEILING TEMPERATURE ORDINARY 135°F/I55°F 570C168°C ORANGE/RED 100°F 380c INTERMEDIATE I750F/200°F 79°C193°C YELLOW/GREEN 150°F HIGH 286 F I41C BLUE 225°F 107 C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 5 17-846-4583 • FAX 5 17-846-923 1 NOVEMBER 2000 A-7 BULLETIN GL280 I QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE *LENGTH FINISHES 2.8 (39 metric) 1/2 NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4 (5.7 cm) **Satin Chrome Bright Chrome 5.6 (80 metric) /2" NPT 2 /4" (5.7 cm) White Polyester-f 7.8 - (1 11 metric) /2' NPT 2 114" (5.7 cm) Black Polyester+ 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated NOTE: METRIC CONVERSIONS ARE APPROXIMATE. "HORIZONTAL SIDEWALL IS 9/16. -FINISHES AVAILABLE ON SPECIAL ORDER. +AVAILABLE AS UL LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE K FACTOR 135°F 57°C 155°F 68°C 175°F 79°C 200°F 93°C 286°F 141°C U.L.F CANADIAN U.L. F. M L.P.C. N.Y.C.- D.O.B. MEA I0I-92-E 2.8 X X X X X X X --- --. x 4.2 - X X X X X X X ---- --- X PENDENT 5.6 X X X X X X X X X X RECESSED t 7.8* X X X X X X X X --- X 8.1 X X X I X X X X X X X 2.8 X X X X X X X --- --- x HORiZONTAL SIDEWALL 4.2 X X X X X X X --- --- X RECESSED § 5.6 X X X X X X X --- --- X 8.1 X X IX X I X IX X --- --- X § HORIZONTAL SIDEWALL U.L. AND C-U.L. LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING. f LISTED FOR ALL HAZARDS. CROSS SECTIONS * 17/32' X /2" ORDERING INFORMATION SPECIFY Quantity - Model Number Style Orifice Thread Sizes Temperature Finishes desired Quantity - Recessed Wrenches - P/N 325391 (112"); P/N 325401, Rev. F (L.O.) GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workman- ship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 2 15/16 DI*.---. REDUCER RETAINER \ 11' 1/8.I 111*. MAX. PENDENT N .116 f *1*, 6111. I 29/32 L HORIZONTAL SIDEWALL LOBE® -FIRE SPRINKLER,-,. CORPORATION °. NOVEMBER 2000 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 5 17-846-4583 FAX S 17-846-9231 1-800-248-0278 www.globesprinklercom PRINTED U.S.A. BULLETIN GL2801 Bulletin 154 Model G4A Concealed- .-.. Automatic Sprinkler The Concealer® A Concealed Sprinkler With a 1/2" or 11/2" Adjustment Features ½" Cover Plate Adjustment Simple sturdy cover attachment Smooth aesthetic ceiling profile Factory installed protective cap Available in brass, chrome or black plated and white painted finishes Ordinary temperature rating Multiple orifices for design flexibility Threaded coverplate does not require clips or springs Listed by Underwriters Laboratories Inc. and Underwriters' Laboratories of Canada, NYC MEA 258-93--E. - Quick Response Sprinkler. Approved by Factory Mutual Research Corp.— Standard...VespOnsO Sprinkler. U.S. Patent number 4,880,063 Application The ReIbIe Model G4A Concealer' is the most ver- satile quick response con- - cealed sprinkler available. It provides the best form of fire protection while offering an attractive appearance and - . -- 1/2 inch of cover adjustment for ease of installation. The small diameter cover plate is easily and positively at- tached and blends into the ceiling, concealing the most dependable fire protection available, an auto- matic sprinkler system. The Model G4A Concealer® is designed for use where aesthetic appearance is important. Offices, hospitals, motels and restaurants are but a few of the applications where is can be used. It is available in different orifice sizes allowing the designer to opti- mize system performance, thereby achieving a very ellicienl installation. The Model G4A Concealer® is a UL Listed Quick Response Conca1ed sprinkler intended for use in accordance with NFPA 13. FM Approves ..ths sprin- kler asa stàndãrd response concealed sprinkler in- tended for use in accordance with FM Loss Prevention Data Sheet 2-8N. Product Description The Reliable Model G4A Concealer® uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate and sprinkler cup assemblies are attached using a strong threaded engagerrent. This threaded engagement provides 112" of cover adjustment. The cover plate is attached to the skirt using 135°F ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the cover plate melts, allowing the release of this part and thus exposing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflectOr to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflec- tor is properly located below the ceiling. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQues ten Parkway, Mount Vernon, Nw York, 10552 Installation Approval Organizations Ordering Information the 134Ace eiiin,g,.w1c; L riters Laboratories Inc. - buick 1. Sprinkler Model Nro have positive Pressure in the space ah?. After a 2/8 inch diameter hole is cut in the ceiling, the Uilclerwriters' Laboratories of -a Cover Plate Finish 4. Inlet Type sprinkler is easily installed with the Model G4 Wrench. Canada - Quick Response Cover Plate Finishes((2 The wrench has drive tangs which insert into the cup Factory Mutual Research Corp. slots. When installing a sprinkler the wrench is first POSI - Standard Response White Paint tioned into the sprinkler/cup assembly until the wrench Light Hazard Bronze tangs engage the drive slots in the top of the cup (there Occupancies - Bright Brass Plated are two sets of drive slots in the cup). The sprinkler is No Limitations Chrome Plated then tightened into the pipe fitting. When inserting or re- Ordinary Hazard Black Plated moving the wrench from the sprinkler/cup assembly Occupancies Groups 1 '"Other finishes and colors are care should be taken to prevent damage to the sprinkler. & 2, Wet Systems Only available on special order. factory DO NOT WRENCH ON ANY OTHER PART OF THE 4 NYC MEA 258..93-E Consult for details. SPRINKLER/CUP ASSEMBLY. Final adjustment of the - Quick Response '21FM Approval of the painted cover is made by hand turning the cover in the clock- finish is limited to white and oft white paint. All plated finishes wise direction until it is tight against the ceiling. Note: Approvals are for light and are FM Approved. A protective cap is provided to protect the drop-down ordinary hazard, except for small sprinkler deflector from damage which could occur dur- orifice sprinklers which are urn- UU Listing Category ing construction before the cover plate is installed. The ited to light hazard. The cup and skirt are fabricated from plated Sprinklers, Automatic and cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re-install cap until the cover Opensteel and are intended for interior non-corrosive applications Quick Response Sprinkler plate is installed. - Note: Paint or any other coat- inns arr,Id over the f'tnry fin- tiLl Guide Number VNIV f- ish will void all approvals and Standard TemDeratUres warranties. [1111 Classification Sprinkler Cover Plate Max. Ceiling Temp. Ordinary 1650FI74ec 1351F/571C 100'17I38C IntaIlation Data Sprinkler Inlet Total Adjustment Nominal Orifice "K" Factor Thread Approvals US Metric Non Adjustable W' 1/2" 5.62 81.0 W'NPT 1,23,4 Non Adjustable 112~ " 4.24 61.0 1/.- 'NPT 1,2.4 Non Adjustable %' 2.82 40.6 'NPT 1,2,3,4 Adjustabj_.. -.:-1W: . W'. -12-4 .._5S....7.._. . 1" tilF'T Male or..Ferate --:.-. Adustabte. . 1W' ' 4.24 610 1- NPT 1.24 MOdel G4 rfrkIerWrendh [' ---------- 112" NPT Non Adjustable Inlet 1" NPT Male-Adjustable inlet 1" NPT Female-Adjustable Inlet Figure 1 Figure 2 Figure 3 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association. Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting tile and property to, over 70 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United Stales. Canada and foreign countries Manufactured by 1IN,1 -i The Reliable Automatic Sprinkler Co., Inc (800) 431- V88 Sales OlI:crs (800) 8,18 -6051 Sates Fax (914)668-3070 Corporate 011ices i.)rT Internet Address dnt Rcyj \•/ Rv'.'ucn hrlra s twl.-11F, j-i.jled o. new Ucla E 0 Prrved U S I-. I )L% p(l.,( 9999570 I