HomeMy WebLinkAbout2815 JEFFERSON ST; ; AS060061; Permit9/14/22, 11:00 AM AS060061 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: AS060061
2815 JEFFERSON
Job Address: Status: ISSUED
ST
Permit Type: SPRINK Applied 4/5/2006
Parcel No: 2031102900 Approved: 4/5/2006
Lot #: 0
Reference No.: Issued: 4/5/2006
PC #: Inspector:
Project Title: KENT JESSE OFFICE BLDG FIRE SPRINKLER PLAN CHECK &
INSPECTIONS FOR 5 SUITES
Applicant:
WESTERN FIRE PROTECTION
12232 THATCHER CT
P0 WAY CA
858-513-4949
Owner:
BICAJESSEE ADVENTURES L L C
2075 CORTE DEL NOGAL #S
CARLSBAD CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
L 575 0 575 0
about:blank 1/1
NM41011i,13
G
LOBE®
FIRE SPRINKLER
CORPORATION
QUICK RESPONSE
A UTOMA TIC SPRINKLERS
GL SERIES
RECESSED PENDENT
RECESSED HORIZONTAL SIDEWALL
DESCRIPTION AND OPERATION
The Globe Quick Response GL Series Sprinkler is a low profile yet
durable design which utilizes a 3mm'frangible glass ampule as the
thermosensitive element. This provides sprinkler operation approxi-
mately six times faster than ordinary sprinklers. While the Quick f ( \ Response Sprinkler provides an aesthetically pleasing appearance, it can
be installed wherever standard spray sprinklers are specified but offers
the additional feature of greatly increased safety to life. Quick Response - a
Sprinklers should be used advisedly and under the direction of approving -. -
authorities having jurisdiction.
The heart of Globe's GL Series sprinkler proven actuating assembly QUICK RESPONSE
is a hermetically sealed frangible glass ampule that contains a precisely RECESSED PENDENT measured amount of fluid. When heat is absorbed, the liquid within the
bulb expands increasing the internal pressure. At the prescribed -
temperature the internal pressure within the ampule exceeds the
strength of the glass causing the glass to shatter. This results in water
discharge which is distributed in an approved pattern depending upon the
deflector style used.
1
TECHNICAL DATA
See reverse side for Approvals and Specifications. -
Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C),
200°F (93°C), 286°F (141-C).
Water Working Pressure Rating - 175 Psi (12 Bars). QUICK RESPONSE
Factory tested hydrostatically to 500 psi (34 Bars). RECESSED
HORIZONTAL SIDEWALL
Maximum low temperature glass bulb rating is -67°F (-55°C).
Frame - bronze Deflector - brass Screw - brass
Bulb seat - copper Spring - nickel alloy Seal - teflon
Bulb - glass with alcohol based solution, 3mm size.
Escutcheon Assembly - steel
SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
AVAILABLE SPRINKLER BULB I N.F.P.A. MAXIMUM
I
CLASSIFICATION
I TEMPERATURES I COLOR I CEILING TEMPERATURE
ORDINARY 135°F/I55°F 570C168°C ORANGE/RED 100°F 380c
INTERMEDIATE I750F/200°F 79°C193°C YELLOW/GREEN 150°F
HIGH 286 F I41C BLUE 225°F 107 C
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 5 17-846-4583 • FAX 5 17-846-923 1
NOVEMBER 2000 A-7 BULLETIN GL280 I
QUICK RESPONSE
A UTOMA TIC SPRINKLERS
GL SERIES
RECESSED PENDENT
RECESSED HORIZONTAL SIDEWALL
SPECIFICATIONS
NOMINAL "K" FACTOR THREAD SIZE *LENGTH FINISHES
2.8 (39 metric) 1/2 NPT 2 1/4" (5.7 cm) Factory Bronze
4.2 (59 metric) 1/2" NPT 2 1/4 (5.7 cm) **Satin Chrome Bright Chrome
5.6 (80 metric) /2" NPT 2 /4" (5.7 cm) White Polyester-f
7.8 - (1 11 metric) /2' NPT 2 114" (5.7 cm) Black Polyester+
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated
NOTE: METRIC CONVERSIONS ARE APPROXIMATE. "HORIZONTAL SIDEWALL IS 9/16.
-FINISHES AVAILABLE ON SPECIAL ORDER.
+AVAILABLE AS UL LISTED CORROSION RESISTANT
WHEN SPECIFIED ON ORDER.
APPROVALS
STYLE K
FACTOR
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C U.L.F CANADIAN
U.L. F. M L.P.C. N.Y.C.- D.O.B.
MEA I0I-92-E
2.8 X X X X X X X --- --. x
4.2 - X X X X X X X ---- --- X
PENDENT 5.6 X X X X X X X X X X RECESSED t
7.8* X X X X X X X X --- X
8.1 X X X I X X X X X X X
2.8 X X X X X X X --- --- x
HORiZONTAL SIDEWALL 4.2 X X X X X X X --- --- X
RECESSED § 5.6 X X X X X X X --- --- X
8.1 X X IX X I X IX X --- --- X
§ HORIZONTAL SIDEWALL U.L. AND C-U.L. LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING.
f LISTED FOR ALL HAZARDS. CROSS SECTIONS * 17/32' X /2"
ORDERING INFORMATION
SPECIFY
Quantity - Model Number Style
Orifice Thread Sizes Temperature
Finishes desired
Quantity - Recessed Wrenches - P/N 325391 (112"); P/N
325401, Rev. F (L.O.)
GLOBE® PRODUCT WARRANTY
Globe agrees to repair or replace any of its own manufac-
tured products found to be defective in material or workman-
ship for a period of one year from date of shipment.
For specific details of our warranty please refer to Price
List Terms and Conditions of Sale (Our Price List).
2 15/16 DI*.---.
REDUCER RETAINER \ 11'
1/8.I 111*. MAX.
PENDENT
N
.116 f *1*, 6111. I 29/32
L
HORIZONTAL
SIDEWALL
LOBE®
-FIRE SPRINKLER,-,.
CORPORATION
°.
NOVEMBER 2000
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
5 17-846-4583 FAX S 17-846-9231
1-800-248-0278 www.globesprinklercom
PRINTED U.S.A. BULLETIN GL2801
Bulletin 154
Model G4A
Concealed- .-..
Automatic Sprinkler
The Concealer®
A Concealed Sprinkler
With a 1/2" or 11/2" Adjustment
Features
½" Cover Plate Adjustment
Simple sturdy cover attachment
Smooth aesthetic ceiling profile
Factory installed protective cap
Available in brass, chrome or
black plated and white painted
finishes
Ordinary temperature rating
Multiple orifices for design flexibility
Threaded coverplate does not require
clips or springs
Listed by Underwriters Laboratories Inc.
and Underwriters' Laboratories of
Canada, NYC MEA 258-93--E. - Quick Response Sprinkler. Approved by
Factory Mutual Research Corp.—
Standard...VespOnsO Sprinkler.
U.S. Patent number 4,880,063
Application
The ReIbIe Model G4A
Concealer' is the most ver-
satile quick response con- -
cealed sprinkler available. It provides the best form of fire protection while offering an attractive appearance and - . --
1/2 inch of cover adjustment
for ease of installation. The
small diameter cover plate is
easily and positively at-
tached and blends into the ceiling, concealing the
most dependable fire protection available, an auto-
matic sprinkler system.
The Model G4A Concealer® is designed for use
where aesthetic appearance is important. Offices,
hospitals, motels and restaurants are but a few of the
applications where is can be used. It is available in
different orifice sizes allowing the designer to opti-
mize system performance, thereby achieving a very
ellicienl installation.
The Model G4A Concealer® is a UL Listed Quick Response Conca1ed sprinkler intended for use in accordance with NFPA 13. FM Approves ..ths sprin-
kler asa stàndãrd response concealed sprinkler in-
tended for use in accordance with FM Loss
Prevention Data Sheet 2-8N.
Product Description
The Reliable Model G4A Concealer® uses a proven quick response fusible element in a standard
style sprinkler frame with a drop-down deflector. This
assembly is recessed into the ceiling and concealed
by a flat cover plate. The cover plate and sprinkler
cup assemblies are attached using a strong
threaded engagerrent. This threaded engagement
provides 112" of cover adjustment. The cover plate is
attached to the skirt using 135°F ordinary tempera-
ture classification solder.
When the ceiling temperature rises, the solder
holding the cover plate melts, allowing the release of
this part and thus exposing the sprinkler inside to the
rising ambient temperature.
The subsequent fusing of the element opens the
waterway and causes the deflectOr to distribute the
water. Any secure engagement between the cover
plate and cup will assure that the drop-down deflec-
tor is properly located below the ceiling.
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQues ten Parkway, Mount Vernon, Nw York, 10552
Installation Approval Organizations Ordering Information
the 134Ace eiiin,g,.w1c; L riters Laboratories Inc.
- buick
1. Sprinkler Model
Nro have positive Pressure in the space ah?.
After a 2/8 inch diameter hole is cut in the ceiling, the Uilclerwriters' Laboratories of -a Cover Plate Finish
4. Inlet Type
sprinkler is easily installed with the Model G4 Wrench. Canada
- Quick Response Cover Plate Finishes((2 The wrench has drive tangs which insert into the cup Factory Mutual Research Corp. slots. When installing a sprinkler the wrench is first POSI - Standard Response White Paint
tioned into the sprinkler/cup assembly until the wrench Light Hazard Bronze
tangs engage the drive slots in the top of the cup (there Occupancies -
Bright Brass Plated
are two sets of drive slots in the cup). The sprinkler is No Limitations Chrome Plated
then tightened into the pipe fitting. When inserting or re- Ordinary Hazard Black Plated
moving the wrench from the sprinkler/cup assembly Occupancies Groups 1 '"Other finishes and colors are care should be taken to prevent damage to the sprinkler. & 2, Wet Systems Only available on special order.
factory DO NOT WRENCH ON ANY OTHER PART OF THE 4 NYC MEA 258..93-E Consult for details.
SPRINKLER/CUP ASSEMBLY. Final adjustment of the - Quick Response '21FM Approval of the painted
cover is made by hand turning the cover in the clock- finish is limited to white and oft
white paint. All plated finishes wise direction until it is tight against the ceiling. Note: Approvals are for light and are FM Approved.
A protective cap is provided to protect the drop-down ordinary hazard, except for small
sprinkler deflector from damage which could occur dur- orifice sprinklers which are urn- UU Listing Category
ing construction before the cover plate is installed. The ited to light hazard. The cup and
skirt are fabricated from plated Sprinklers, Automatic and
cap is factory installed inside the sprinkler cup. Remove
cap to install sprinkler, then re-install cap until the cover
Opensteel and are intended for interior
non-corrosive applications Quick Response Sprinkler
plate is installed.
-
Note: Paint or any other coat-
inns arr,Id over the f'tnry fin-
tiLl Guide Number
VNIV f- ish will void all approvals and
Standard TemDeratUres warranties.
[1111 Classification Sprinkler Cover Plate Max. Ceiling Temp.
Ordinary 1650FI74ec 1351F/571C 100'17I38C
IntaIlation Data
Sprinkler Inlet Total
Adjustment
Nominal
Orifice
"K" Factor Thread Approvals US Metric
Non Adjustable W' 1/2" 5.62 81.0 W'NPT 1,23,4
Non Adjustable 112~ " 4.24 61.0 1/.- 'NPT 1,2.4
Non Adjustable %' 2.82 40.6 'NPT 1,2,3,4
Adjustabj_.. -.:-1W: . W'. -12-4 .._5S....7.._. . 1" tilF'T Male or..Ferate --:.-.
Adustabte. . 1W' ' 4.24 610 1- NPT 1.24 MOdel G4 rfrkIerWrendh
['
----------
112" NPT Non Adjustable Inlet 1" NPT Male-Adjustable inlet 1" NPT Female-Adjustable Inlet
Figure 1 Figure 2 Figure 3
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association. Factory Mutual
Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting tile and property to, over 70 years, and are installed and serviced by the most highly qualified
and reputable sprinkler contractors located throughout the United Stales. Canada and foreign countries
Manufactured by
1IN,1 -i
The Reliable Automatic Sprinkler Co., Inc
(800) 431- V88 Sales OlI:crs
(800) 8,18 -6051 Sates Fax
(914)668-3070 Corporate 011ices
i.)rT Internet Address
dnt Rcyj
\•/
Rv'.'ucn hrlra s twl.-11F, j-i.jled o. new Ucla
E 0 Prrved U S I-. I )L% p(l.,( 9999570 I