Loading...
HomeMy WebLinkAbout2425 JEFFERSON ST; ; AS150204; Permit9/14/22,11:05 AM AS150204 Permit Data City of Carlsbad Sprinkler Permit 2425 JEFFERSON Job Address: ST Permit Type: SPRINK Parcel No: 1551403800 Lot #: 0 Reference No.: Permit No: AS150204 Status: APPROVED Applied 7/14/2015 Approved: 7/14/2015 Issued: 7/14/2015 PC #: Inspector: Project Title: HAGEY RESIDENCE INSTALLATION OF A NEW 13D FIRE SPRINKLER SYSTEM IN A SINGLE FAMILY DWELLING Applicant: PREMIER FIRE PROTECTION P0 BOX 2027 LAKESIDE, CA 619-871-9795 Owner: HAGEY FAMILY TRUST 07-03-13 P0 BOX 1665 CARLSBAD CA Fees ($) I Add'l Fees ($) Total ($) Balance ($) 280 0 280 0 abaut:blank 1/1 Parsley Consulfing Plan Review Comments for Hagey Residence page 2 of 2 1) There was an error in the hydraulic calculations. The plans show the piping from the base of the riser to the meter as 11/4" PVC, while the calculations show this diameter as 1 ½". A quick evaluation, attached to the calculations, shows the required pressure at the source will increase by slightly more than 2.0 psi if the smaller diameter is installed. This would reduce the pressure margin at the source to 24.2 (26.2-2.1), with a required pressure of 49.4 psi. This would equal approximately 67% of the available supply pressure, which does not exceed the maximum of 90% allowed. No resubmittal or revision to the plans is required. The following comments are for your information and will appear on every residential sprinkler review. The alarm bell must be capable of being heard, above background noise, with doors closed, in all living areas of the residence. This will be checked at final acceptance. Pressure required at base of riser will be verified to be available at time of final acceptance. Sprinkler heads are omitted from bathroom areas under 55 SF in area with noncombustible plumbing fixtures. Fixtures will be verified at final acceptance. Sprinkler head blockage or pattern disruption caused by beams or other obstructions will be verified to not exist at final acceptance inspection. Sprinkler heads should be located the proper distance from heat sources (stoves, kitchen ranges, fireplaces, heat diffusers, etc.) This will be checked at final acceptance inspection. Sprinkler heads located in an unconditioned space (garage, water heater closet, etc.) should be fast response type with an appropriate temperature rating, commercial heads are acceptable in these areas. All exposed piping shall be black steel or copper. Concealed piping can be CPVC plastic. File: C:\Plan Reviews\Rev2 15267.1 .Docx HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.8 - SUBMITTAL. ENGINEERS : PREMIER FIRE PROTECTION. (619)-390-5047. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. LICENSE : 939040 DESIGNER : STEVE PETRI DATE : 06-29-2015 FILE : C:\RESDEN58\HAGEY.RES JOB NAME : HAGEY RES . TWO HEAD CALC 16 X 16 LOCATION : 2425 JEFFERSON STREET DESIGN DATA. it DESIGN CRITERION: 13D MIN SPR FLOW : 13 Gpm AREA PER SPRINKLER : 256 Sq Ft TOTAL CALCULATED AREA : 512 Sq Ft TOTAL SPRINKLERS CALCULATED : 2 FLOW DATA. TOTAL SPRINKLER FLOW : 26.1 Gpm DOMESTIC DEMAND : 5.0 Gpm TOTAL WATER REQUIRED : 31.1 Gpm BASE OF RISER NODE : B FLOW : 26.1 Gpm PRESS : 32.7 Psi AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE PHONE These plans have been reviewed for apparent compliance whit the current appliahlc codes and staidards in lowe in the jurisdiction. The ooner or contractor ittav utiliie his rev iesv support it all application for a building perch' svith the express understanding that this rectess in to was relics on the oss ncr or contractor or their prolcrnioital engineer or architect icr sole respocisihuluty For lull eoiitplcance with said Codes and staitdards. cctcIuidui the hnildiiict code or for ans.respotisthcllv or rieticiencies. errors. on issuons or tteczltureiice cit these plan whetiter or not noled it) this review, Oalc:ii s- Reviewer: RECOM MENI) AIPRi)VAI. RECOMMEND A'I'Rt'vAt.. AS t )T-:f) (') FYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.8 - SUBMITTAL. Page ENGINEERS : PREMIER FIRE PROTECTION. (619)-390-5047. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. JOB : HAGEY RES . TWO HEAD CALC 16 X 16 DATE: 06-29-2015 FILE: C:\RESDEN58\HAGEY.RES I SPRINKLER MANUF : VIKING I MODEL : VK457 I DENSITY : 0.05 Gpm/Sq Ft FIXED PRESS : 6.0 Psi I AREA / SPR : 256 Sq Ft DESIGN AREA : 512 Sq Ft I SPRINKLER Q : 13.0 Gpm I NODES : 10 PIPES : 9 SOURCE I STATIC : 75 Psi RESIDUAL : 74 Psi FLOW : 31 Gpm NODE ELEVATION K-FACTOR PRESSURE DISCHARGE NO. Feet Psi Gpm ----------------------------------------------------------- 1 21.0 4.90 7.0 13.0 2 21.0 4.90 7.2 13.1 3 21.0 7.4 4 21.0 17.1 T 11.0 25.7 B 0.0 32.7 A 0.0 37.4 DOME 5.0 Al 0.0 39.3 M 0.0 45.3 S 0.0 SOURCE 47.8 31.1 SPRINKLERS FLOWING : 2 AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 512 Sq Ft MIN SPRINKLER FLOW : 13 Gpm REQUIRED DENSITY : 0.051 Gpm/Sq Ft COMPUTED DENSITY : 0.051 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 26.1 Gpm TOTAL DOMESTIC FLOW : 5.0 Gpm TOTAL WATER REQUIRED : 31.1 Gpm TOTAL SPRINKLER PRESS : 41.8 Psi FIXED PRESS LOSS : [J psi Copyright (2012) SUPPLY PRESS AVAILABLE : Psi by DEMAND PRESS REQUIRED : 47.8 Psi Hydronics Engineering PRESSURE CUSHION : Psi 34119 Fremont Bi, Suite 609 Fremont, CA, 94555 MAXIMUM VELOCITY : 12.8 F/S (800) 845-9819 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.8 - SUBMITTAL. Page 2 ENGINEERS : PREMIER FIRE PROTECTION. (619)-390-5047. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. JOB : HAGEY RES . TWO HEAD CALC 16 X 16 DATE: 06-29-2015 FILE: C:\RESDEN58\HAGEY.RES PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FRI-LOSS (Psi) END DIAMETER TOTAL (Psi/Ft) 1 q= 13.0 K= ------------------------------------------------------------------------------- 4.90 L= 7.0 Pt 7.0 Pt 7.0 1 Q= 13.0 F= B F= 5.0 C= 150 Pe 0.0 Pv -0.1 • Vel= 4.4 D= 1.101 TL= 12.0 0.0306 Pf 0.4 Pn 6.9 3 Pt 7.4 2 q= 13.1 K= 4.90 -------------------------------------------------------------------------- L= 2.0 Pt 7.2 Pt 7.2 2 Q= 13.1 F= B F= 5.0 C= 150 Pe 0.0 Pv -0.1 Vel= 4.4 D= 1.101 TL= 7.0 0.0312 Pf 0.2 Pn 7.0 3 Pt 7.4 3 q= 0.0 K= 0.00 -------------------------------------------------------------------------- L= 63.0 Pt 7.4 Pt 7.4 3 Q= 26.1 F= 11RBB4EF= 25.0 C= 150 Pe 0.0 Pv -0.5 Vel= 8.8 D= 1.101 TL= 88.0 0.1114 Pf 9.8 Pn 6.9 4 Pt 17.1 4 q= 0.0 K= 0.00 -------------------------------------------------------------------------- L= 23.0 Pt 17.1 Pt 17.1 4 . Q= 26.1 F= RRLL F= 16.0 C= 150 Pe 4.3 Pv -0.5 Vel= 8.8 D= 1.101 TL= 39.0 0.1114 Pf 4.3 Pn 16.6 T Pt 25.7 T q 0.0 K= 0.00 -------------------------------------------------------------------------- L= 10.0 Pt 25.7 Pt 25.7 5 Q= 26.1 F= RRSC F= 10.0 C= 150 Pe 4.8 Pv -0.5 Vel= 8.8 D= 1.101 TL= 20.0 0.1114 Pf 2.2 Pn 25.2 B Pt 32.7 B q= 0.0 K= 0.00 -------------------------------------------------------------------------- L= 5.0 Pt 32.7 Pt 32.7 6 Q= 26.1 F= LLL F= 21.0 C= 150 Pe 0.0 Pv -0.8 Vel= 10.8 D= 0.995 TL= 26.0 0.1824 Pf 4.7 Pn 31.9 A Pt 37.4 q= 5.0 DOME L= 60.0 Pt 37.4 Pt 37.4 7 , fl' ) Q= 31.1 F= LLEECC F= 12.0 C= 150 Pe 0.0 Pv -0.2 \ )) Vel= 5.0 D= 1.590 TL= 72.0 0.0257 Pf 1.9 Pn 37.3 --------------------------------------------------------------------------- Pt 39.3 Al Q= 31.1 Pt 39.3 MET FIXED PRESSURE LOSS Valve 6.0 M Pt 45.3 M q= 0.0 K= 0.00 -------------------------------------------------------------------------- L= 10.0 Pt 45.3 Pt 45.3 8 Q= 31.1 F=G F= 0.0 C=150 Pe 0.0 Pv -1.1 Vel= 12.8 D= 0.995 TL= 10.0 0.2522 Pf 2.5 Pn 44.2 S -------------------------------------------------------------------------- Pt 47.8 Q= 31.1 <<< -------------------------------------------------------------------------- -------------------------------------------------------------------------- SOURCE >>> Pt 47.8 E=45-Elb L=90-Elb B=TeeBch R=TeeRun C=CouPlg S=SwgChk G=GatVlv HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.8 - SUBMITTAL. ENGINEERS : PREMIER FIRE PROTECTION. (619)-390-5047. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. JOB : HAGEY RES . TWO HEAD CALC 16 X 16 FILE : C:\RESDEN58\HAGEY.RES DATE : 06-29-2015 PSI FIRE SPRINKLER HYDRAULIC GRAPH 90 80 70 60 50 40 30 20 10 100 150 200 250 300 -0 Water Supply 350 400 450 500 FLOW - GPM Static : 75 Psi Resid : 74 Psi Flow : 31 Gpm S Water Demand Avi Press : 74.0 Psi @ 31 Gpm Req Press : 47.8 Psi @ 31 Gpm Press Cush: 26.2 Psi Copyright: Hydronics Engineering, 2012. 34119 Fremont Bi, Suite 609 Fremont, CA 94555. (800) 845-9819. Same Flow - Different Pipe Diameter Flow (Q) 31 31.000 Size (D) 1.59 1.36 C-Factor 150 150 LPF 0.026 0.055 Velocity 5.009 6.847 Length 72.000 72.000 Pf 1.840 3.939 Difference 2.098585739