Loading...
HomeMy WebLinkAbout2730 GATEWAY RD; ; FA130015; Permit9/14/22, 2:07 PM FA130015 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA130015 Status: PENDING Applied 3/18/2013 Approved: Job Address: 2730 GATEWAY RD Permit Type: FALARM Parcel No: 2132632600 Lot #: 0 Reference No.: PC #: Project Title: PIZZA PORT NEW Issued: Inspector: Applicant: Owner: ALARMS UNLIMITED, INC. MARSAGLIA PROPERTIES L L C 4584 PARK BL. SAN DIEGO, CA P0 BOX 1697 CARLSBAD CA 619-297-4500 Fees ($) Add'I Fees ($) Total ($) Balance ($) 286 0 , 286 0 about:blank 1/1 D SILENT KNIGHI by Honeywell çintelliKnight® Model 5700 / Single Loop Addressable ciire Alarm Control System) The affordable addressable fire alarm control panel solution. IntelliKnight Model 5700 is a class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic lntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 supports SD or 5K devices. 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features ____ Built-in support for up to9)detectors and50 SK modules creating a total point capacity of,10joints Built in support for up to 50 SD devices Up to 125 zones and 125 output groups Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC Drift compensation 13 pre-programmed output cadences (including ANSI- 3.41) and 4 programmable outputs (iiification circuits configurable as 1 Class A (Sty' (or 2 Class B (Style Y), or auxiliary powerfor resettable,) (constant, or door holder power; Built-in synchronization for AMSECO, Gentex®, Faraday, System Sensor® and Wheelock® appliances Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) Two built-in Form C programmable relays rated at 2.5A at 27.4 VDC ' Improvements in SKSS1iver five times faster upload/downloads Built-in RS-232 interface for programming via PC Built-in Form C trouble relay rated at 2.5A at 27.4 VDC Programmable date setting for Daylight Saving Time Installation The 5700 is a surface mount FACP Compatibility The 5700 SLC supports multiple device types of the same protocol: SK (System Sensor) SD You cannot mix SD. and SK devices on a FACP. t I < 1 :JJ 2 2 2 5496 Model 5700 Fire Alarm Control Panel IVL 111, -$X4h.±4ff '4,O.4b W3y F1ttt BVeSflB* 5700 - Specifications S-BUS Accessories Miscellaneous Accessories Electrical 58601R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC; 120 VAC 60 Hz i5A Features the same 80 character backlit LCD User-friendly Windows software for remote Total Accessory Load 2.5A @ 27.4 Vbd display keypad and firefighters key switch programming of 5700s using a PC Upload Notification Power: 2.5A 27.4 Vpp'l power-limited as the 5700. The system can be fully and view panel account information, event programmed and operated from any 5860. history, and detector status. Standby Current: 200 m Alarm Current: 325 mAl 5860 is gray and 5860R is red. 5 70 Silent nug Software Suite Notification/Aux Power 5496 Intelligent Power Module End-user facility management software 2.5A @ 27A VDC per circuit A 6 amp notification power expander that allows viewing of detector status and event power-1iiiit6d provides four additional power-limited history via modem or direct connection. Battery Charging Caoacitv: 7.0-35.0 AH +,ci,-t;.,n annlkn, circuit ntr,,,f Battery Size: 7 A max allowed inFACP VV cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Physical Dimensions: 12.75" W 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ3IX (two required) Approvals NFPAI3, NFPA15, NFPA16, NFPA7O, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170 0559 144 MEA42992E 5880 LED/10 Module• Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16"W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) 5D505-DTS-K Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505-DUCTR. Hochiki and 5K Devices See the specification sheets listed below for a complete listing of the Hochiki and SK devices. 53624 SD Devices Specification Sheet 53623 5K Protocol Devices Specification Sheet DSILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 by Honeywell Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA PIN 350392 Rev I-I © 2012 Honeywell international inc. 5860 Color 5860R: Red 5860: Gray Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non- condensing Approvals NFPA 72; UL Listed; SFM 7170-0559135 MEA429-92-E Vol. IX; FM Approved DSILENT KNIGHT p by Hi1Qywd 5860 Remote Annunciator 1W Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your lntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the lntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description Features include an 80-character backlit LCD providing easy-to- understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence Install up to eight 5860s per FACP Available in red or light gray Support for simultaneous use of multiple 5860s RS-485 interface to panel Operation and appearance is identical to 5860 built-in annunciator On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved Electrical Specifications (tandby Current 20 mAi 'arm Current 25 mA' Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 lbs (1.3 kg) Wire Rms liJp to GOG Feet Froai FACP $ 5860 8 5880 UP -to ego 5a per Sytm Ccpip*fW I! *1Kgtkt FACP 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Compatibility lntelliKnight 5820XL FACP lntelliKnight 5808 FACP ntel!iKnight 5700 FACF? Ordering Information 5680R Remote Annunciator Four line LCD annunciator with 20 characters per line. Red. 5680 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring For surface mounting. 5860TG Gray Trim Ring For surface mounting. IF ~rpww SILENT' This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are FORM# 350224 Rev C, 05/06 subject to change without notice. For more information, contact Silent by HM"w4d Knight 7550 Meridian Circle Suite 100, Maple Grove, MN 55369-4927. © 2007 Honeywell International Inc. Phone: (800) 328-0103, Fax: (763) 493-6475. D SILENT (j496 Intelligent KNIGHT (Power Module by Honeywell A dynamic combination of power and intelligence for your notification expansion needs. The Model 5496 Intelligent Power Module by Silent Knight is the most-powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®, Gentex®, Faraday, AMSECO and Wheelock® - what you need to drive power-hungry components like ADA notification appliances. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost-effective notification power supply available, you need Model 5496. Call Silent Knight today for more information at 1-800-328-0103. Model 5496 Intelligent Power Module The model 5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the IntelliKnight Model 5808 Fire Control /Communicator. The 5496 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5496 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. The Output circuits can be programmed as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). Features UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Built-in synchronization for appliances from AMSECO, Gentex5, Faraday, System Sensor®, and Wheelock® 24 VDC filtered output voltage Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B NAGs are programmable as Notification Appliance Circuits, or as auxiliary power to be used as constant, resettable, or door holder power 3 amps per output circuit Ground fault detector Communicates to the FACP via 4- wire SBUS (wire runs up to 6000 ft) AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders Lightweight design adds to ease of installation and reduces shipping costs UL 864,1481 & 1971 listed ANSI Cadence pattern output capability built-in Specifications AC Input 120 VAC at 2.7 A Output: 24 VDC at 6 amps Current: Standby 40 mA Alarm 160 mA Notification/Aux. Power circuits: 4 Output configuration: 2 Class A (Style Z) 4 Class B (Style Y) (1 Class A& 2 Class B) Amps per output circuit: 3.0 (6.0 amps total) Notification circuit output: 20.4 to 27.3 VDC @ 3.0 amps each, 4.7k EOL resistor required on each Class B circuit Battery charging capacity: 35.0 AH Model 5496 Intelligent Power Module Ambient Temp.: 32° to 120° F 0° to 49° C Dimensions: 12.25" W x 16" H x 3" D (30.88 cm w x 40.64 cm H x 7.62 D cm) Approvals: UL CSFM MEA 429-92-E vol. XIV Compatible FACPs ° lntelliKnight 5700 lntelliKnight 5808 lntelliKnight 5820XL Output I Output 2 SBUS Communication To a Compatible Silent Knight FACP Output 3 Output 4 Firepower 5496 Distributed Power Module Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). The power module shall have four separate outputs. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. 4 Outputs Programmable as Notification Appliance Circuits, or as Auxiliary Power Auxiliary Power Can Be - Programmed To Be Constant, Resettable, or Door Holder Power D SILENT This document is not intended to be used for installation purposes. We try V1TT('LI'T to keep our product information up-to-date and accurate. We cannot cover U%.1'J.J1.LL all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact by Honeywell Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA FORM# 350387 Rev D © 2010 Honeywell International Inc. NP SERIES jt4P7-1-2 V VUASA r Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years of experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES Superb recovery from deep discharge. Electrolyte suspension system. Gas Recombination Multipurpose: Float or Cyclic use. Usable in any orientation Superior energy density. Lead calcium grids for extended life. Manufactured World wide. Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Iow Maintenance Operation Duo the 3rfectly sSaled construction and the recombination of gasses within the cell, the battery is / almostrnaintenane free. Layout E) Terminals / Fastcin tab! 187 A Faston tab! 2.so D - O4 ThTGI = IvtM °° °° INCH IVIM l 250 .35 .310 7.0 • .250 6.35 - 020 0.5c) Nominal Capacity (Ah) NP7-12 20hrt01 .75vpc300C I ohrto I .75vpc201C -6.4 5hr to 1.70vpc 20°C 5.9 1hrto1.60vpc200C 4.2 Voltage 12 Energy Density (WhL20hr) 91 Specific Energy (.kg.20hr) 32 mt. Resistance (m.Ohms) 25 Maximum discharge (A) 40/75 Short Circuit current (A) 210 Dimensions (mm) Length 151 Width 65 Height overall 97.5 Weight (Kg) 2.65 Terminal AID Layout 4 Terminal TorqüeNm - Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. General Specifications NP DISCHARGE CHARACTERISTICS CURVES AT 252C (77°F) FOR A NOI0. C - Given aopocliy B Mated weach U•Oey nAP BATTERY BATTERY 13.0 6.5 NP AT25C)TTF) 12.0 6.0 11.0 6.0 10.0 6.0 (0 0.0 4.5 6.5 40 MINUTES DISCHARGE TIME HOURS FLOAT SERVICE LIFE NP RANGE now III1Ii III imuiiimm u aii.i.. • Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge - 15°C to 50°C Discharge - 20°C to 60°C Storage - 20°C to 50°C (fully charged battery) SELF DISCHARGE CHARACTERISTICS i 0c (32-F) so (104- 2 ITF) : 12 l5 1 STORAGE TIME (MONTHS) FLOAT CHARGE CHARACTERISTICS 02SCA- 2.275VP0 CONSTANT VOLTAGE CHARGING )%) (.CA) IV) AT2OC (OVF) r 140 120 0.21 TOO CHAQ5 nIAE - - - (6,0 100 0.20 - evcojo (4,0 005 0.60 /" ., :,snts 111"k *AEA IAVeAREE : : 1111iCKIIIIIIL 2 4 6 CHARGING TIME 0101.165) TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING CONDITIONS EI$CHARGE CURRENT, O.TTCNnp.IF.V I.7VICELI. CHARGING CURRENT 0.500 Anep. 4 CHARGING VOLUME. 1161101 DISCHARGED CAPACITY )AH%) AMBIENT TEMPERATURE OITC TO 2ITC (ONF TO WV) 100% S N. 30%OEPT DOD DOE OP O)ACH AGE (0 - 0_S AOl 100 1Q00 000 NUMBER OF CYCLES NP SERIES — NP7-12 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications Separators The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials. ,. SMAOO(CM5A • 0.3 150 Il lbo..I Th,.115 0.05 106 CO-W Miss" 14 i± __lot 0 0 Thn. TEST146 copomoNs FLOATING VOLTAGE 2.275VPC AMBIENT TEMPERATURE. 20C I6BFTO TITFT :— 02" M" ~ MS. 1 2 3 4 5 5,5 LIFE (YEARS) Yuasa Battery Inc. Distributed by 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1 548820 Yr IJASA I (',st Nni NP7-17 lolnhlolry fl &ddressab CF~k ot-o- e I ect ri qjy_j~)i Smoke Dete Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. IntelIiKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS Analog I Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSprove MEA approved FM Approved SD505-APS Smoke Detector Specifications Operating Voltage: 17-41 VDC Current Consumption: Alarm:' .55 In A) Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: SD5O5-6A (Sold Separately) (6" Base) SD505IAB (4 Base) DSILENT KNIGHT by Honeywell Height = 2 inches, Including base Eel MR No Model SD505-APS Addressable Photoelectric Type Smoke Detector Z~s Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base 5D505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter 3-15116" Model SD505-6AB Detector Base (front view) Model SD505-APS Detector Head (front view) D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all L%.L'.I1JiJ specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350225 Rev C,. 05/05 Copyright © 2005 Silent Knight CP_P500_-P§)and SD500-PSDA (Addressable_Pu!i-StationD InteIIiKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knights lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an lntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features UL Listed SFM llstQ ADA compliant Key reset (Same key as Silent Knight enclosures) Surface mount back box available Terminals - accept up to 14 gauge wire Corrosion-resistant gold-plated contacts. Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Cnt) 55mA CAlarm Current:, S D500-PS Ambient Temperature: 32°F to 120°F (0°c to 49°c) Mounting: Single gang box - Optional Red Surface Mount Box PS-SMBB D SILENT XNIGIIT FACP SD500-PSDA Installing SD500-LK D SILENT KNIGHT A 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. Mounting to Single Gang Electrical Box 0 c Mounting to Optiona Surface Mount Box t: Wiring I ''! - IDtriiaI must be Dimensions MADE IN AMERICA FORM# 350342, Rev. 09/03 Copyright © 2003 Silent Knight 65OO-AIM& SD500-MI!! CAddressable Input M od uJ lntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4'-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the lntelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor SD500-AIM supports Class A (Style D) or Class B (Style B) contact monitor wiring SD500-MIM support for Class B (Style B) contact monitor wiring Attractive ivory cover plate with the SD500-AIM Small and lightweight size allows for flexible mounting options with the SD500-MIM DIP switch programmable for fast installation Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications iStandbyCurrent O 55 mA IAljii 23_mAThai for one (device; 46 mA max for two devices (0.55 mA for each additional device Line Resistance: 500 max Mechanical Specifications 5D500-AIM Physical Description Dimensions: 4.9" W x 4.9" H x 1" D (12.4Wx 12.4 H x 2.5 D cm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5" W x 2.5" H x 0.7" D (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing ,JflJc,, Approvals NFPA71 &NFPA72 UL 864 (CS FM 7300-0559: 13 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL 3SILENT * KNIGHT by Honeywell SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate UL Compatible FACPs Ordering Information 5820XL SD500-AIM Input Module 5808 Addressable input module with ivory cover plate. (zQc SD500-MIM Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications areC3 FORM# 350231 Rev D, subject to change without notice. For more information, contact Silent Knight © 2008 Honeywell International Inc by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103 or 763-493-6400 Fax: (763) 493-6475. www.silentknight.com SYSTEM $ SENSOR Selectable-Output) Horns, Strobes, and) Horn 5trobe59 SpectrAlert' Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15,15/75, 30, 75, 95,110,115,135,150,177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING USTED APPROVED 5401 (chimes, horn strobe,, horn,) 3023572 55512 (strobes) MEA approved 7125-1650186 )ndoo, strobes) 7125-1650188 (horn strobes. M6A452-05-E chime strobes) 7135-1650189 (horns. chimes) Alert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 175 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75,95,110,115,135,150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model -listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 41/6 x 411/ x 21/a-inch back box.The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8 diameter x 2.5 high (173 mm diameter x 64mm high) Wall-Mount Dimensions (including lens) 5.6 Lx 4.7"W x 2.5"D (142 mm Lx 119 mm x 64mm D) Horn Dimensions 5.6Lx4.7-Wx 1.3D(142 mm 11919mmWx 33 mm D) Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2) 5.9 Lx 5.0W x 2.2 D (151 mm Lx 128 mm W x 56 mm D) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1' diameter x 2.2 high (180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions (sold as a pack) (TR-HS, TRW-HS) ST Lx 4.8"W x 0.35 D (145 mm Lx 122 mm x 9 m D) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, TRCW-HS) 6.9-diameter x 0.35 high (175 mm diameter x 9 m high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AOS-0395.007 UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 115 - 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA (158) 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 (176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UIL Max. Current Draw (mA DC Input RMS), 2-Wire 16-33 Volts 135 Horn 150 Strobe, 177 High Candela 185 Range (135-185 cd) FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Outout Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tsettings 7, 8, and 9 are not available on 2-wire horn strobe. A05-0395-007 SpectrAlert Advance Dimensions Wall-mount horn strobes Ceiling-mount horn strobes 1 _j. Dia. C 5.181 C I U 30H LJ Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Modell Xescription Wall Horn Strobes Ceiling Strobes tP2R° 2-Wire Horn Strobe, Standard cd*, Red SCR Strobe, Standard cd, Red P2RH° 2-Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red P2W° 2-Wire Horn Strobe, Standard cd, White SCW° Strobe, Standard cd, White P2WHC 2-Wire Horn Strobe, High cd,White SCWH Strobe, High cd, White P4R° 4-Wire Horn Strobe, Standard cd, Red Horns P4RH 4-Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4-Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories SR° Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red SRH°t Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White SW° Strobe, Standard cd, White BBSC-2 Back Box Skirt, Ceiling, Red SWH° Strobe, High cd, White BBSCW-2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes . TR-HS Trim Ring, Wall, Red PC2R° 2-Wire Horn Strobe, Standard cd, Red TRW-HS Trim Ring, Wall White PC2RH 2-Wire Horn Strobe, High cd, Red TRC-HS Trim Ring, Ceiling, Red PC2W°t 2-Wire Horn Strobe, Standard cd, White TRCW-HS Trim Ring, Ceiling, White PC2WH° 2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White Notes: Add -Pto model number for plain housing (noFlRE marking on Cover), e.g., P2R-P. t Add -SPto model number for"FUEGO marking on cover, e.g., P2R-SP * 'Standard cd'refers to strobes that include 15, 15175, 30, 75, 95, 110, and 115 candela settings. 'High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. t "\ 5}'CraII7 02009th system Sensor. \. I - 3825 Ohio Avenue. St. Charles, IL 60174 Prodoespedfit09ssobotroongewlihour notice. C0systernrensor.rorrr(ot _$ SENSOR' Phone: 800-SENSOR2 Fax: 630-377-6495 sormot product Information, nd ng th&etent version olthis data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM rej_. LISTING No. 17165-0559:9j Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywell.com DESIGN: Models *lFp..50 and570,Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: IFP 50 5700J (ControL Unft 7628 EOL Resistor c560/5860R!RA-1000 (Annunciator) 5897 Power Supply 5496 *Notification Power Expander 5824 Serial/Parallel Interface 5865-3/5965-4 LED Annunciator 5880 LED 10 Module 5883 Relay Interface Board SD500-LIM Line Isolation Module 5D505-61 B Isolation Base RA-100 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E(CSFM Listing No. 06911-1446:102); EVX-2ZAor EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. Rev 10-3-08 MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Iff c i , operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2012 Listing Expires ne30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Listing No. 7165-0559:0144 Page 2 of 2 NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM rP09J-- LISTING No 1011132" Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywelI.com DESIGN ffi SDSOO ARM Relay odule and SDSOO AIM 5D500 MIM Addressab input Modules*. Models 5D500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models 5D500-AIM and -MIM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ( operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2012 Listing Expires ',June-30, ioi3) Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM rej LISTING No. t5-1653.0i) Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. ModelsçP2R P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. ModelsPC2R) PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *hornlstrobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct I If.•f i , operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2012 Listing Expires une 30, Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM r1pegi -i LISTING No. 15-1653:01 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Synchronous type strobe lights, Models SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177 *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ( operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires '.June3O,2O13j Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Description 4AWG 2/C FPLR-CL2R) Compliance: UL Standards 13 & 1424; NEC Articles 725 & 760 Construction: Conductor 14 AWG Solid Bare Copper No. of Conductors 2 Insulation Type Polypropylene Color Black, Red Thickness 0.010" nom. Diameter 0.084" nom. Lay Length 3.0" nom. Jacket Type PVC Color Red Thickness 0.016" nom. Diameter 0.202" nom. Legend (Ink Print) HONEYWELL PIN 4313 2C14 3038058 (ETL) FPLR OR CL2R C(ETL)US FT4 SUN RES RoHS) W/O# XXXXXX-XXXXXX XXXXFT DEVICE/ZONE A B C D E F 1 234 56789 Properties: Temperature Rating -20 to 75°C Operating Voltage 300 Volts max. Capacitance 18 pf/ft nom. Impedance 82 Ohms nom. DC Resistance 2.54 Ohms/M' at 75°C Flame Rating UL 1666 Riser, C(UL) FT4 REV A 09/01/10 OA GENESIS SERIES Description (9AWG2/CSOLFPLR-CL2R) Compliance: UL Standards 13 & 1424; NEC Articles 725 & 760 Construction: Conductor 16 AWG Solid Bare Copper No. of Conductors 2 Insulation Type Polypropylene Color Black, Red Thickness 0.006" nom. Diameter 0.062" nom. Lay Length 2.0" nom. Jacket Type PVC Color Red Thickness 0.015" nom. Diameter 0.155" nom. Legend (Ink Print) HONEYWELL P/N 4311 2C16 3038058 (ETL) FPLR OR CL2R C(ETL)US FT4 SUN RES RoHS) W/O# XXXXXX-XXXXXX XXXXFT DEVICE/ZONE A B C D E F 12 3 4 56789 Properties: Temperature Rating -20 to 75°C Operating Voltage 300 Volts max. Capacitance 23 pf/ft nom. Impedance 70 Ohms nom. DC Resistance 4.919 Ohms/M' at 75°C Flame Rating UL 1666 (Riser), C(UL) FT4 REV A 09/01/10 OA A El CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RN LISTING No. CATEGORY: LISTEE: DESIGN: Page 1 of 1 7161 -- CABLES-FIRE PROTECTIVE SIGNALING GENESIS CABLE SYSTEM7701 95TH Street, Pleasant Prairie, WI 53158 Contact: Orville Allen (262) 947-0720 Fax (262) 947-0724 Email: orville@genesiscable.com [Mod& FPL FPLP and FPLR power hmited fire protective signaling cable' INSTALLATION MARKING APPROVAL: Conductors: In accordance with the standard Insulation: GPT-150, Foam PP, HDPE or LDPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp., Grade GA-91-84, GPT-45, GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. Listees name, Type "FPL" and UL label. Listed as power-limited fire protective signaling cables. Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not of an endorsement or recommendation of the item listed. This listing should not be used to verify correct ( operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires (]e 30, 2011-35) Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division