Loading...
HomeMy WebLinkAbout6269 EL FUERTE ST; ; FPC2020-0080; Permitft2f1i iI liii '1.]I:4l C7cityof Carlsbad Print Date: 03/12/2021 Permit No: FPC2020-0080 Job Address: 6269 EL FUERTE SI, CARLSBAD, CA 92009-3094 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2131221800 Track #: Applied: 04/28/2020 Valuation: $1,984,662.45 Lot #: Issued: 05/26/2020 Occupancy Group: Project #: 0EV06040 Finaled Close Out: 02/03/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: PACIFIC RIDGE SCHOOL Description: PACIFIC RIDGE SCHOOL -REVISED PLANS TO INSTALL AN ADDITION TO EXISTING FIRE ALARM SYSTEM FOR ANEW BUILDING (ADDRESSABLE, 91 DEVICES) Applicant: FPContractor: iii ENTERPRISES THE STEINHILBER CORPORATION SALOMON GOMEZ 533 S VINEWOOD ST 115 MARKET PL ESCONDIDO, CA 92029-1924 ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 (760) 747-3050 x216 FEE AMOUNT FIRE Plan Review Per Hour - Office Hours $136.00 FIRE Reinspection (per inspection) $193.00 FIRE TI Fire Alarm System $620.00 Total Fees: $949.00 Total Payments To Date: $949.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 11P ENTimpmaml FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS PACIFIC RIDGE SCHOOL MULTI-DISCIPLINARY INNOVATION CENTER 6269 EL FUERTE STREET CARLSBAD, CA 92009 FIRE ALARM SYSTEM MA-TERI-At-DAT 51 BILL OF MATERIALS FARENHYT RPS-1000 6AMP REMOTE NAC POWER SUPPLY W/5815XL SLC EXPANDER CSFM# 7165-0559:0505 SILENT KNIGHT SKE-450 VOICE EVACUATION CONTROL PANEL CSFM# 6911-0559-0141 FARENHYT IDP-PHOTO ADDRESSABLE SMOKE DETECTOR CSFM# 7272-0559:0149 FARENHYT IDP-HEAT ADDRESSABLE HEAT DETECTOR CSFM# 7270-0559:0147 COOPER WHEELOCK ET-1010-R WEATHERPROOF SPEAKER ONLY - CEILING MOUNTED CSFM# 7320-0785:0105 COOPER WHEELOCK E90-24MCC-FW SPEAKER/STROBE COMBINATION - WHITE CSFM# 7125-0785:0152 WHEELOCK EXCEDER STC CEILING MT STROBE ONLY - WHITE CSFM# 7125-0785:0168 FARENHYT IDP-MINIMON ADDRESSABLE MONITOR MINI-MODULE CSFM# 7300-0559:0132 SILENT KNIGHT IDP-RELAY ADDRESSABLE RELAY MODULE CSFM# 7300-0559:0132 / Agency Listings MEA !i approved II,s-Jn1,o - RPS-1 000 Compatibility RPS-1000 is compatible with the following FACPs: IFP-2000/RPS-2000 (63 max per panel) IFP-2000ECS (63 max per panel) lFP-1000 (8 max per panel) lFP-I000ECS (8 max per panel) IFP-100 (8 max per panel) lFP-100ECS (8 max per panel) IFP-50 (8 max per panel) Installation RPS-1000 can be surface or flush mounted. Farenhyt D SILENT KNIGHT by Honeywell RPS-1000 intelligent distributed power module adds 6.0 amps of power, six FlexputTM I/O circuits, and two Form C relay circuits to a compatible Farenhyt addressable system. RPS- 1000 connects to the FACP via the RS-485 system bus allowing up to an additional 6,000 feet of wiring. Each RPS- 1000 is optically isolated providing ground loop isolation and transient protection. RPS-1000 supports its own backup battery and monitors the AC power. The Flexput circuits can be programmed as notification appliance circuits, continuous, resettable, or door holder power, or as conventional initiation circuits for 2 or 4-wire smoke detectors and contact devices (e.g. pull stations). Features Six onboard Flexput circuits programmable for: Notification appliance circuits (Class B/Style Y & Class A/Style Z) Conventional initiation circuits (Class B/Style B & Class A/Style D) both 2- and 4-wire Auxiliary power (for door holders, continuous power, or resettable power) 6.0 amps output power Supports Class A (Style 6) and Class B (Style 4) configuration of the SBUS Two Form C programmable relays rated at 2.5A @ 24 VDC Ground loop isolation and transient protection Provides SBUS optical isolation and re-conditions the RS- 485 signal Built-in synchronization for apliances from System Sensor®, AMSECO, Gentex R Faraday, and Wheelock® Up to 6,000 foot wiring distance from the RPS-1000 Battery charging capacity is 35 Ah Large cabinet size can house two 18 Ah backup batteries or RBB accessory cabinet can house battery sizes larger that 18 Ah Room to mount two 5815XL SLC expander modules 6 Amp Intelligent Distributed Power Module RPS-1 000 P/N 350070 Rev K Copyright © 2016 Honeywell International Inc. T. C, 0 I Programmable for NACs, Auxilary Power, or Conventional Initiation Input Circuits (2- or 4-wire) RPS-1000-1 RPS-1 0 rcimL Programmable for NACs, 00 Auxilary Power, or U Conventional Initiation Input U Circuits (2- or 4-wire) M co co liii', D Programmable for NACs, Auxilary Power, or j Conventional Initiation )WLD L Input Circuits (2- or 4-wire) 111111 Isre.luuu-I COUC I I I Icre.1UuU- CUC To Next RPS-1000 LEW 5815X1 1 RA4000s 5824 5815XL RA-1000 SLC ' Devices Devices —p SLC Specifications Electrical Approvals Primary AC: • UL 864 120 VRMS, 50 or 60 Hz, 2.7A, or • NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72, & 240 VRMS 50 or 60 Hz, 1.4A NFPA 101 Total Accessory Load: 6A @ 24 VDC • CSFM Current: Standby: 40 mA Alarm: 160 mA MEA 429-92-E Vol. IX FM Flexput Circuits: Notification: 3 amps per circuit (6A system total) Initiation: 100 mA power limited @ 24 VDC Physical Mounting Dimensions: 14.5"W x 24.75"H x 3.9"D (36.8 cm W x 62.9 cm H x 9.8 cm D) Overall Dimensions: 16.1"W x 26.4"H x 4.1"D (40.6 cm W x 67 cm H x 11.8 cm D) Color: Red Environmental 581's L7:D Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non-condensing SK-SCK OSHPD (CA) OSP-0065-10 Ordering Information RPS12O0:j Intelligent Distributed Power Module. Specify 120 VAC or 240 VAC operation when ordering. Remote Battery Box Accessory Cabinet. 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) Remote Battery Box Accessory Cabinet. 20W x 12" H x 7.5" D SLC Expander Module Seismic Compliance Kit Accessories RBB AB-55 D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all KNIGHT requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, by Honeywell Fax: (203) 484-7118. For Technical Support, Please call 800446-6444. www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. U 2 p-05S9 Page 1 of 3 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Silent Knight Model IFP-2100 and IFP-2100ECS, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only) and mass notification services (IFP-2100ECS). *The CELL-MOD and CELL-CAB-SK have the option to be configured by a compatible control unit for the following pathways: Cellular only without a backup path, primary Cellular communication path, or secondary Cellular communication path. Model IFP-2100 System Components: RA-100 Remote Annunciator RA-1000 Remote Annunciator RA-1000R Remote Annunciator RA-2000 Remote Annunciator RA-2000GRAY Remote Annunciator 6815 Signal Line Circuit Expander for IDP/SK devices 5815XL Signal Line Circuit Expander for IDP/SK devices RPS-1000 Power Supply 5496 NAC Expander 5824 Serial/Parallel Module 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface RBB Remote Battery Box (16'WX10"HX6'D) SK-SCK Seismic Complaince Kit SK-NIC Network Inerface Card SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RFP-2 100 Remote Fire Alarm Panel without built in display, Red RFP-2100 Remote Fire Alarm Panel without built in display, Black *Rev 10-02-19 gt ', This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, M.E., F.P.E., Program Coordinator Fire Engineering Division Listing No. 7165-0559:0505 Page 2 of 3 Model IFP-2100ECS System Components: ECS-50W 50 Watt Amplifier ECS-50WB 50 Watt Amplifier, Black ECS-125W 125 Watt Amplifier ECS-125WB 125 Watt Amplifier, Black ECS-DUAL50W 50 Watt Dual Amplifier ECS-DUALSOWB 50 Watt Dual Amplifier, Black ECS-lNT50W 50 Watt Internal Amplifier ECS-50WBU External Backup Amplifier ECS-CE4 Provides 4 addiional audio circuits ECS-RVM Remote Voice Module ECS-SW24 Switch Expander ECS-NVCM Network Voice Control Module ECS-LOC Local Operator Console *ECS-LOC2100 Local Operator Console RA-100 Remote Annunciator RA-1000 Remote Annunciator RA-1000R Remote Annunciator RA-2000 Remote Annunciator RA-2000GRAY Remote Annunciator 6815 Signal Line Circuit Expander for lDP/SK devices 5815XL Signal Line Circuit Expander for lDP/SK devices RPS-1000 Power Supply 5496 NAC Expander 5824 Serial/Parallel Module 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface SK-SCK Seismic Complaince Kit SK-NIC Network Inerface Card SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RFP-2100 Remote Fire Alarm Panel without built in display, Red RFP-2100 Remote Fire Alarm Panel without built in display, Black RATING: Primary Operating Power Supply: 120VAC, 60HZ, 3.25A Secondary Operating Power Supply: 24VDC, 750 mA, 55Ah *Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, M.E., F.P.E., Program Coordinator Fire Engineering Division Listing No. 7165-0559:0505 Page 3 of 3 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and indicating devices and for mass notication. Refer to listee's Installation Instruction Manual for details. *Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, M.E., F.P.E., Program Coordinator Fire Engineering Division UK SKE-Series Voice Evacuation Listing/Approvals UL Listed MEA approval 429-92-E Vol. XI CSFM Listed D SILENT KNIGHT by Honeywell SKE-Series Voice Evacuation System Model SKE-450, Model SKE-450-ZN4 I ZN6 The SKE-Series Voice Evacuation System provides maximum flexibility to accommodate your voice evacuation requirements The SKE-Series Voice Evacuation system provides 50 watts of output power. The SKE-Series system consists of several different models, the SKE-450, SKE-450-ZN4 or SKE-450-ZN6. Each model has a built in Digital Message Repeater, power supply and a supervised microphone. All models have two alarm inputs, one triggered by reverse polarity and one by supervised dry contact trigger. The system supports 25 or 70.7 VRMS operation to accommodate most installations. The audio messages are field programmable via the built in microphone, through the line level input, or by downloading via the internet. The models SKE-450-ZN4 (w/4-zone splitter) and SKE-450-ZN6 (w/6- zone splitter) also contain a zone splitter capable of dividing the speaker output into 4 or 6 separate outputs. SKE-Series Voice Evac. System The SKE-450 and SKE-450-ZN4/ZN6 voice evacuation are activated when one of the two alarm inputs are tripped. When this occurs the control will output a pre-recorded audio message corresponding to the alarm input that was tripped. The repetition of the digital audio message and the selected notification output are completely programmable. The SKE-450-ZN4/ZN6 comes equipped with a 4 or 6 zone splitter respectively, capable of dividing the speaker output from the amplifier into four or six Class B or Class A outputs. The zone splitter also has an All Call feature that will activate all speaker zones regardless of the individual toggle switch settings. Both models provide seven visual indicators for, Speaker Trouble, Alarm, Microphone Trouble, Command 2 Trouble, Earth Ground Fault, Low Battery, and Power. Features 50 watts of output power on a 25 or 70.7 VRMS speaker circuit. The speaker circuit can be Class A or B. Provides maximum flexibility for new or retrofit jobs. Downloadable Voice Messages via direct connect. If you need a different message download it from the SK website free of charge! Digital Message Repeater -Built in to the SKE motherboard. No additional wiring to install makes setup fast and easy. Capable of storing three messages, messages one and two are built in messages of up to 30 seconds. Message three is field programmable and can be up to 45 seconds long. Digital Signal Processor -Processes digital quality audio, generates tones and provides control functions. Supervised Microphone -The built in supervised microphone provides system paging function and field message programming capability. Dead Front Cabinet - Provides protection for users, prevents tampering with system electronics. Dedicated relays-Built in form "C" relays for alarm and trouble increase flexibility and keeps installation cost down. Two Inputs-One reverse polarity input and one supervised dry contact input provides maximum flexibility. Built in system power is capable of operating the system and charging system backup batteries. The SKE-ZN4 zone splitter provides four Class B or Class A output circuits (each loop can draw 50 watts, with maximum of 50 watts total for whole system). The SKE- ZN6 zone splitter provides six Class B or Class A output circuits (20 watts per circuit, with 50 watts max for the whole system). Both splitters provide paging by zone or all call. SKE-Series Voice Evacuation System Model SKE-450 and Model SKE-450-ZN4 Engineering Specifications The system shall contain a voice evacuation system to supervise and operate UL listed voice evacuation speakers. The system shall have a built in UL listed power supply. The system shall be capable of supporting an optional UL listed zone splitter that can be housed in the main voice control cabinet. In addition, the system will issue pre-recorded voice commands locally for purpose of evacuation. The system must support a minimum of two pre-recorded messages and have the capability of adding application specific messages through the use of a PC. The voice evacuation system shall have the ability to provide a supervised microphone for the purpose of audible local instructions that will override the pre-recorded messages. The system shall contain a dead front panel inside the enclosure to protect the circuitry from tampering and to protect the operator from hazardous voltages. Specifications Speaker Wiring Operating Voltage: 120 Vrms @ 60Hz I *230 Vrms @ 50Hz (*ask for -IV version) Current Draw: Standby: 140 mA Alarm: 590 mA ZN4 Current Draw: Standby: 45 mA Alarm: 250 mA (all channels) Flush Mount Dimensions: Height: 24.75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3-7/16" (8.73 cm) with 5/8" protruding Overall Dimensions Height: 26-3/8" (67 cm) Width: 17-3/16" (43.66 cm) Total Depth: 4" (10.16 cm) Operating Temp.: 32 to 120 F (0 to 49 C) Humidity: 10 to 93% RH Optional Accessories SKE-V70 Module—Converts speaker circuit voltage from 25 to 70.7 Vrms. Current Draw: Standby 10 mA; Alarm: 70 mA. SKE-SRM—Supervised remote microphone. Current Draw: Standby & Alarm: 30 mA. ZN6 Current Draw Standby: 35 mA Alarm: 120 mA (all channels) Command I Wiri7 Q 4W4W11 Dotted Line Is Class A I II I EOL Resistor and (Style Z) Supervision I II I Solid Line Is for jt (t1) Class B (Style Y) Supervision Alarm parity shown E01-Resistor and Solid Line Is Class B (Style 'I') Supervision Command 2 Wiring 40 4141431 I 2) Dotted Line is return wives for Class A (Style Z) Supervision FACP D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350794 Rev B a subject to change without notice. For more information, contact Silent Knight Copyright © 2009 Honeywell International Inc by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 4059Q14l Page 1 of I CATEGORY: 6911 -- VOICE COMMUNICATION SYSTEMS CONTROL UNITS LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Model SKE-426 and SKE450,*ZN4,*ZN6 Voice Evacuation Systems. Power limited. The unit is a single channel, automatic or manual voice evacuation/emergency message panel. The unit is intended to be used in conjunction with a listed electrically compatible fire alarm control unit to provide voice communication, paging, evacuation tone signals, and voice alarm signals with voice override. Refer to listee's data sheet for detailed product description and operational considerations. System components: SKE-426, -450, *..B450 Main Board SKE-ZN4 4-Zone Splitter Module SKE-ZN6 6-Zone Splitter Module SKE-PS3 Power Supply Module SKE-V70 Speaker Card SKE-SRM Remote Microphone RATING: Input: 120 VAC, 240VAC, Standby: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, wiring diagram, applicable codes and ordinances and in a manner which is acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a voice evacuation system for use with a separately listed electrically compatible fire alarm control units. This control unit can generate a distinctive three pulse temporal fire alarm evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: *Rev. 04-21-2006 jw r , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt SILENT KNIGHT by Honeywell Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal IDP-Photo, IDP-Photo-T and IDP-PhotoR The IDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight lFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors. It is UL 268A listed when used with the DNR (W) duct smoke detector. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the IDP-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3601 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System Sensor® PN RA1 OOZ) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed IDP-Photo (Base not Included) Installation The IDP-Photo and IDP-Photo-T plug into a compatible IDP-series detector base. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detector. Compatibility The lDP-Photo, IDP-Photo-T and IDP-PhotoR are compatible with the following IDP-series detector bases: B21OLP 6" Mounting Base B501 4" Mounting Base B224B1 6" Isolator Base B224RB 6" Relay Base B200SR 6" Sounder Base The IDP-Photo, IDP-Photo-T and IDP-PhotoR are compatible with the following FACPs: • IFP-2000 / RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 / ECS Intelligent Fire Panel IFP-100 I ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350280 Rev H Copyright © 2017 Honeywell International Inc. I I I Wiring IDP-Series Detector Mounting Bases Wiring IDP-Series Detector Mounting Bases Specifications* Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) installed in B501 base Electrical Operating Voltage: 15-32 VDC SLC Standby and Alarm Current: 300 pA Environmental Operating Temperature IDP-Photo: 32° - 120°F (0°C - 49°C) IDP-Photo-T: 32° - 100°F (0°C - 38°C) Humidity: 10% - 93% non-condensing Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F (57°C) Velocity: 0 - 4000 fpm (0 - 20 m/sec) (suitable for installation in ducts) IDP-Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal Ordering Information Photoelectric Smoke Detector IDP-Photo-T Photoelectric Smoke Detector with Thermal (135°F) IDP-PhotoR Photoelectric smoke detector, remote test capable, for use with DNR (W) duct smoke detector Accessories RA100Z Remote LED Annunciator. XR213 Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the T55-127-000. M02-04-01 Detector Test Magnet. M02-09-00 Test Magnet with Telescoping Handle. XP-4 Extension Pole for XR2B. Extends from 5— 15 ft. T55-127-000 Detector Removal Head. BCK-200B Black Detector Kit. For IDP-series detectors. * Unless otherwise noted, specifications apply to IDP-Photo and IDP-Photo-T. ] SILENT This document is not intended to be used for installation purposes. We try to keep our product information up- ' to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications KNIGHT are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7~72=0569,0_t4p Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models IDP-PHOTO, lDPPHOTOR*, IDP-PHOTO-T, lDP-ACCLIMATE, SK-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models IDP-PHOTO and IDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW(OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt Intelligent Thermal and Rate-of-Rise Thermal Detectors IDP-Heat, IDP-Heat-HT, & IDP-Heat-ROR The IDP-Heat, IDP-Heat-HT, and IDP-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Heat is a fixed temperature thermal detector that uses a thermistor sensing circuit to produce 135°F (57°C) fixed thermal detection. IDP-Heat-HT is a variable high temperature detector that provides high temperature detection at 135°F - 190°F (57°C - 88°C). IDP-Heat-ROR is a fixed temperature and rate-of-rise thermal detector that uses a thermistor sensing circuit to produce 135°F (57°C) thermal protection. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Innovative thermistor sensing circuit Superior EMI resistance for reliability Variety of mounting options to meet any application Dual LED indicators for 3601 visibility Detector transmits signal to indicate maintenance is required Plug-in mounting provides ease of installation Optional remote LED annunciator (System Sensor® PN RA100Z) Tamper-proof feature available on mounting bases Rotary address switches for fast installation UL Listed Installation The IDP thermal detectors plug into a compatible IDP-series detector base. Compatibility The IDP-Heat, IDP-Heat-HT, and IDP-Heat-ROR are compatible with the following IDP-series detector bases DSILENT KNIGHT by Honeywell Agency Listings US L MEA IDP-Heat Installed in the B21OLP Mounting Base (Base Not Included) B21OLP 6" Mounting Base B501 4" Mounting Base B224B1 6" Isolator Base B224RB 6" Relay Base B200SR Sounder Base The IDP-Heat-HT, and IDP-Heat-ROR are compatible with the following FACPs: lFP-2000 I RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 I ECS Intelligent Fire Panel IFP-100 / ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel The IDP-Heat is compatible with the following FACPs: IFP-2000 / RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 I ECS Intelligent Fire Panel IFP-100 / ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350285 Rev G Copyright © 2015 Honeywell International Inc. Wiring IDP-Series Detector Mounting Bases Wiring IDP-Series Detector Mounting Bases Specifications* Ordering Information Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 4.8 oz (136 g) Electrical Operating Voltage: 15 - 32 VDC SLC Standby and Alarm Current Draw: 300 pA Environmental Operating Temperature IDP-Heat & IDP-Heat-ROR: 40_ 100°F (-20°C - 38°C) IDP-Heat-HT: -40 - 150°F (-20°C - 66°C) Humidity: 10% - 93% non-condensing Thermal Ratings IDP-Heat: Fixed temperature setpoint 135°F (57°C) IDP-Heat-HT High temperature heat 135°F - 190°F (57°C - 88°C) IDP-Heat-ROR: Rate-of-rise detection 15°F/mm (9°C/mm) MP-- 19- Fixed Temperature Thermal Detector IDP-Heat-HT Fixed High Temperature Thermal Detector IDP-Heat-ROR Fixed Temperature and Rate-of-Rise Thermal Detector Accessories RA100Z Remote LED Annunciator XR213 Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the T55-127-000 M02-04-00 Replacement Test Magnet. M02-09-00 Test Magnet with Telescoping Handle XP-4 Extension Pole for XR2B. Extends from 5— 15 ft T55-127-000 Detector Removal Head BCK-200B Black Detector Kit. For IDP-series detectors * Unless otherwise noted, specifications apply to all IDP thermal detectors. D SILENT This document is not intended to be used for installation purposes. We try to keep our product T information up-to-date and accurate. We cannot cover all specific applications or anticipate all KN IGHT requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: SILENT KNIGHT SECURITYOne Fire-Life Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models IDP-HEAT and SKHEAT* (fixed temperature), IDP-HEAT-ROR,IDP-HEAT-HT, SKHEATROR*, and SKHEATHT*(fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 135°F fixed temperature for Models lDP-HEAT, IDP-HEAT-ROR, SKHEAT* and SKHEATROR* 190°F fixed temperature for Model IDP-HEAT-HT and SK-HEAT-HT INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with *listees separately listed compatible base and fire alarm control units. Refer to listee's Installation Instructions Manual for details. XLF: 7270-0028:0196 *Rev. 07-14-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Weatherproof appliances, Version 2 Description Designed for life safety, performance and reliability, the Wheelock weatherpoof notification appliances nclude: Weatherproof Appliances Series Strobes RSSWP Horn strobes ASWP Horn AH-24WF AH-12WP Multitone horn strobes MTWP Multitone horns MT Speaker strobes ET70WP Speakers All strobe models are UL dual listed—meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —40°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Eaton provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA° and WFPA° kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See Table 10 on page three of this document for a summarization of these mounting options and the required accessories. All models may be synchronized using the Wheelock DSM sync modules, Wheelock power supplies or other manufacturers panels incorporating the Wheelock patented sync proto- col. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system. MT horns may be synchronized, using the temporal Code 3 horn setting. Powering Business Worldwide Technical Data TD450112EN February 2019 Features & benefits Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 660C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Strobes and Code 3 horn synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Models with field selectable tone, dBA and candela settings Wall or ceiling mounting options Surface or semi-flush mounting (indoor and outdoor( IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal Wheelock AH, AS, MT, RSS, ET70 j4 4.80 2.55—H I F Figure 2. ASWP front and side views Note: Please read these specifications and associated installation instructions, before using, specifying, or installing this product. Visit Eaton.com/massnotification for current installation instructions, Approvals & compliances Approvals include: UL Standards 1971, 1638, 464 and 1480; ULC, California State Fire Marshal (CSFM); and Factory Mutual (FM) (see agency approvals by model number on pages 4 and 5 of this document) The series RSSWR ASWR AH-24WR MTWP-2475W, and MT-12/24 have UL/ULC approval down to —40°F. The ET-1010 and ET70WP have UL approval down to —40°F. Compliance with the following requirements: NFPA; UFC; FCC, ANSI 117.1; OSHA Part 29, 1910.165; AD General notes Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Models are available in red or white. Contact Customer Service for order code and delivery. Drawings 4.80 0.602 © FIRE ©T r 4.80 © FIRE ©I L Figure 1. RSSWP front and side views 5.126 - I I ., A 4~_ t oo 00001] o°o 5.126 0.65 Figure 3. MTWP front and side views L-5.120 .l - '*- 5.368 ,0'0001 1.120 So So Figure 4. ET70WP front and side views Figure 5. MT front and side views 2 EATON www.eaton.com Wheelock AH, AS, MT, RSS, ET70 Technical Data TD450112EN February 2019 IN 4.29 __ H 4.09 H [ 4.4. J.29 Figure 6. ET-1010 front and side views Table 1. Maximum RMS current for AH models UL Max Current for AH 24 VDC High (99) dBA 0.080 Table 2. dBA ratings for ET-1010 and ET70WP models UL Reverberant dBA @ loft. Watts Model 1/8 1/4 1/2 1 2 4 8 Med (95) dBA 0.043 ET1010 77 80 83 86 87 92 94 Low (90) dBA 0.021 ET70WP 77 88 83 86 88 91 93 Table 3. Maximum RMS current and dBA, MT weatherproof models MTWP/MT MT ULC Anechoic dBA at 10 Feet 24vDC 12VDC dBA HI STD HI STD 24VDC 12VDC Horn 0.108 0.044 0.177 0.034 92 87 92 87 Bell 0.053 0.024 0.095 0.020 86 80 86 80 March Time 0.104 0.087 0.142 0.034 89 84 89 84 Code 3 Horn 0.122 0.035 0.200 0.034 88 83 88 83 Code 3 Tone 0.135 0.035 0.152 0.021 85 80 85 80 Slow Whoop 0.098 0.037 0.142 0.035 90 85 90 85 Siren 0.104 0.036 0.152 0.030 89 84 89 84 Hi/Lo 0.057 0.025 0.114 0.026 86 81 86 81 Table 4. Strobe and ASWP ratings Candela ratings Maximum RMS Current for ASWP Max RMS Current Strobe Candela UL 1971 UL 1638 t8 77F UL 1638 @-40F (strobe only) High Mod Low 2475W 300 180 115 0.138 0.168 0.155 0.150 2475C 15 180 115 0.138 0.168 0.155 0.150 135 135 56 0.300 0.355 0.340 0.335 185 185 77 0.420 0.480 0.465 0.460 115 115 47 0.300 0.355 0.340 0.335 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 24177 177 177 73 0.420 0 Wall mount rating only EATON www.oaton.com 3 Technical Data TD450112EN Wheelock AH, AS, MT, RSS, ET70 February 2019 Wall mount models Table 5. Specification and ordering information Agency Approvals Model Number Finish Order code UL ULC CSFM FM Strobe RSSWP-2475W-FR Red 9013 X X X X RSSWP-2475W-FW - - White 3034 X X X X RSSWP-24MCWH-FR Red 5161 X X X - RSSWP-24MCWH-FW - White 5165 X X X - Audible strobe ASWP-2475W-FR Red 9012 X X X X ASWP-24MCWR-FR Red 5137 X X X - ASWP-24MCWH-FW White 5140 X X X - Multitone strobe MTWP-2475W-FR Red 8420 X X X X MTWR-2475W-FW White 3112 X X X X MTWP-24MCWH-FR Red 5132 X X X - MTWP-24MCWH-FW White 5134 X X X - Speaker strobe ET70WP-2475W-FR Red 9077 X X X ET70WP-2475W-FW White 3179 X X X ET70WP-24185W-FFI Red 4885 X X X ET70WP-24185W-FW - White 4891 X X X Ceiling mount models Table 6. Specification and ordering information Agency Approvals Model Number Finish Order code UL IJLC CSFM FM Strobe RSSWR-2475C-FR Red 4338 X X X X FISSWP-2575C-FW White 4446 X X X X RSSWP-24MCCH-FR Red 5167 X X X - RSSWP-24MCCH-FW White 5187 X X X - Audible strobe ASWR-2475C-FR Red 4251 X X X X ASWF-2475C-FW White 4502 X X X X ASWP-24MCCH-FR Red 5149 X X X - ASWP-24MCCH-FW White 5157 X X X - Multitone strobe MTWP-2474C-FR Red 4457 X X X X MTWP-2475C-FW White 4458 X X X X MTWP-24MCCH-FR Red 5102 X X X - MTWP-24MCCH-FW White 5122 X X X - Speaker strobe ET70WP-2475C-FR Red 4452 X X X ET70WP-2475C-FW White 4454 X X X ET]0WP-2417]C-FR Red 4845 X X X ET70WP-24177C-FW White 4859 X X X 4 EATON www.eaton.com Wheelock AH, AS, MT, RSS, ET70 Technical Data TD450112EN February 2019 Wall or ceiling mount models Table 7. Specification and ordering information Agency Approvals Model Number Finish Order Code UL IJLC FM Audible AH-24WP-R Red 7416 X X X Horn MT-12/24-R Red 5023 X X X MT-1 2/24-W White 5024 X X X : Speaker - ET-1010-R '-' -'- Red 3135 X Available X ET-1010-W White 3137 X Available X - I Mounting accessories Table 8. Ordering information Model Number Finish Order Code Model Number Finish Order Code Backboxes Gasket kit l0B-R ® Red 5046 WP-KIT N/A 4486 1013-W (D ' White 5047 Flush plates WFPA-R Red 4698 WFPA-W White 4701 WPSBB-R @ Red 9751 White 3033 - 01 WFP-R Red 4696 WPSBB-WcD WFP-W White 4697 WPBB-R Red 9014 White 4692 -0 WPBB-W® Table 9. Mounting options WBB-R Red 2959 WBB-W White 2960 Surface Mount Flush Mount Exposed Mounting Options Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WFP ET70WP Speaker Strobes lOB lOB + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA ® lOB, WPSBB and WPBB models include weep rules and plug in the event that moisture may have AHWP Horns WBB - WFP entered the appliance. ET-1 010 Speakers WBB - WFP MTWP Multitone Strobes lOB lOB + WP-KIT WFP Multitone lOB lOB + WP-KIT WFP Note: Refer to Data Sheet TD450028EN for mounting options EATON www.eaton.com 5 Technical Data TD450112EN Wheelock AH, AS, MT. RSS, ET70 Effective February 2019 Architects and engineers specifications General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit, concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes and Audibles Weatherproof strobe appliances shall be Wheelock RSSWP models or approved equals. The weatherproof strobes shall produce a mini- mum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof audibles shall be Wheelock AH models or approved equals, and the weatherproof audible/strobe combinations shall be Wheelock ASWP models or approved equals. The weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall Wheelock MT models or approved equals. The multitone horns shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone audible/strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. When set to Code 3 Horn, the audible shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. When set to Code 3 Horn, the MT multitone audibles shall be able to be synchronized. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers shall be Wheelock ET-101O models or approved equals, and speaker strobes shall be ET70WP or approved equals. Weatherproof speakers and speaker strobes shall be UL listed for indoor/outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construc- tion for extra protection and improved audibility. Speakers shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker strobes shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 ciBA. Sync Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock DSM sync modules, Wheelock power supplies or other manufacturers panels with built-in Wheelock patented sync protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3-YEAR WARRANTY Eaton 1000 Labs Boulevard Cleveland, OH 44122 United States Eaton .com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 Eaton.com/massnotification © 2019 Eaton E-N All Rights Reserved Eaton is registered trademark. Printed in USA Publication No. TO450112EN All other trademarks are property Powering Business Worldwide February 2019 of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: 8&01.. Page 1 of 1 7320-- SPEAKERS Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com Models ET-1010, ET-101 1, ET-1070, ET-1071, ET-1080, ET-1081, ET-1090 and ET-1091 series speaker or speaker/strobe. Refer to listee's data sheet for product description and operational considerations. In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as a speaker for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. NOTE: *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Wheelock [70 & [90 Speakers & Speaker Strobes Description The Wheelock E70 Wall and E90 Ceiling Speakers and Speaker Strobes are designed for high efficiency sound output for indoor applications. The E product line features intelligible communications with crisp, clear voice messages and tone signaling, ideal for mass notification, and voice evacuation. Providing a sleek aesthetic appearance, the Wheelock Series E High Speaker Strobes feature dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. For visible signaling to meet the hearing impaired, the F Speaker Strobe models incorporate the Low Current draw RSS Strobes. Strobe options for wall mount models include 1575 or Wheelock • patented MCW multi candela strobe with field selectable candela / settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available inWheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The strobe portion of all E Speaker Strobes may be synchronized when used in conjunction with the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels .--.:--. incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy F "IR E The E Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired) and Standard 1480 (Speaker Appliances), and ULC listed under CAN/ULC-5526 (Visual- audible Signal Appliances, Fire Alarm) and under CAN/U LC-S541 (Speakers, Fire Alarm). All inputs employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Color options for the E Speakers and Speaker Strobes are red and white. Mw I W.Tom Powering Business Worldwide Figure 1. E70 (top) and E90 (bottom) Speakers - Front & Side Views Figure 2. E70 (top) and E90 (bottom) Speaker Strobes - Front & Side Views Technical Data TD450024EN Effective January 2016 Features Intelligible Communications Efficient design for high intelligibility at minimum wattage across a frequency range of 400 to 4000 HZ Field Selectable Settings Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi-Candela models) Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (Multi-candela models) Field Selectable Taps 1/8 watt up to 2 watts 25 or 70 VRMS operation Easy-to-Install Low profile design incorporates speaker mounting plate for faster and easier installation Built- in level adjustment feature and an aesthetic two (2) screw grille cover. Quick installation with IN/OUT screw terminals using #12 to #18 AWG wires 4" square backbox prevents wire damage E70 No extension ring required E90 Optional extender (E90 Ext) is available for mounting to 4" square backboxes Strobe Synchronization Components Meet synchronizing standards with Wheelock's DSM Sync Modules, Power Supplies or SAFEPATH products Compliance UL 1971, UL 1480, ULC-S526, ULC-5541 California State Fire Marshal ICSFMI ADA'NFPNANSI/OSHA FCC Part 15, ICES Note:AlI CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.EATON.COM/MASSNOTIFICATION OR CONTACT EATON FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Wheelock [70 & E90 Speakers & Speaker Strobes Drawings General Notes Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range." Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL 1971. 2 EATON www.eaton.com Wheelock E7O&E90 Technical Data 1D450024EN Speakers & Speaker Strobes Effective January 2016 Table 1. Maximum RMS Current UL Max Current a 24MCW/24MCC 24MCWHI24MCCH Regulated Voltage Model Range VDC 15 30 75 95 110 115 135 177 185 E70 16.0-33.0 0.060 0.092 0.165 0.220 0.300 0.420 16.0-33.0 0.065 0.105 0.189 0.249 0.300 0.420 Table 2. UL Listed Models and Ratings UL Reverberant dBA at 10 Feet b Model 1/8 watts C 1/4 watts 1/2 watts 1 watts 2 watts E70 Speaker 72 75 78 81 83 E90 Speaker 72 75 78 81 82 E70 Speaker Strobe 71 75 78 81 83 E90 Speaker Strobe 74 77 80 82 85 Table 3. Specification & Ordering Information Mounting Sync w/ DSM or Model Order U Strobe Candela Red White Lettering Wall Ceiling Options Wheelock Power Supplies Speakers E70-R 9865 X No Lettering X P, 0 E70-W 9866 X No Lettering X P, Cl E90-R 9875 X No Lettering X p Cl E90-W 9876 X No Lettering X p Cl Speaker Strobes E70-24MCW-FR 0183 15/30/75/110 X FIRE X P, 0 X E70-24MCW-FW 0184 15/30/75/110 X FIRE X P.O X E70-24MCW-NW 9748 15/30/75/110 X No Lettering X P, 0 X E70-24MCW-ALR 4123 15/30/75/110 X ALERT X F 0 X E70-24MCW-ALW 4124 15/30/75/110 X ALERT X P.O X E70-24MCWH-FR 0185 135/185 X FIRE X P. 0 X E70-24MCWH-FW 0186 135/185 X FIRE X P.O X E70-24MCWH-ALW 4456 135/185 X ALERT X P. 0 X E70-24MCC-ALR 4308 15/30/75/95 X ALERT X p a x E70-24MCC-ALW 5838 15/30/75/95 X ALERT X p çj x E70-24MCC-NW 1000 15/30/75/95 X No Lettering X p, a x E90-24MCC-FR 0191 15/30/75/95 X FIRE X a x E90-24MCC-FW 0192 15/30/75/95 X FIRE X p.a x E90-24MCC-NW 3181 15/30/75/95 X No Lettering X P, a x E90-24MCC-ALW 4189 15/30/75/95 X ALERT X P. ci x E90-24MCC-ALR 4309 15/30/75/95 X ALERT X p, a x E90-24MCCH-FR 0194 115/177 X FIRE X p,a x E90-24MCCH-FW 0193 115/177 X FIRE X P, a x E90-24MCCH-ALR 0980 115/177 X ALERT X p, a x E90-24MCCH-ALW 2975 115/177 X ALERT X P. a x E90-24MCCH-NW 2974 115/177 X No Lettering X p a x a RMS current ratings are per UL maximum RMS method. UL max Current rating is the maximum RMS Current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage )16v for 24v units). For eudibles the max Current is usually at the maximum listed voltage 133v for 24v units). For unfiltered FWR ratings, see installation instructions. b dBA ratings are based on testing under UL Standard 1480. c 1/8 watt tap is for private mode only. Note: Due to Continuous development of our products, specifications and offerings are subject to Change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. EATON www.eston.cem 3 Technical Data TD450024EN Wheelock E70 & E90 Speakers & Speaker Strobes Effective January 2016 Table 4. Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Weight E70 Speaker: 1.7 lbs (0.77 kg); E70 Speaker Strobe 1.8 lbs (0.82kg); E90 Speaker: 1.5 lbs (0.68 kg); E90 Speaker Strobe 1.6 lbs (0.73 kg) Lens GE Lexan 943A Dimensions E70 Speaker: 5.13' W x 5.13' H x 0.43"D; E70 Speaker Strobe: 5.13" W x 5.13" H x 2.56"D; E90 Speaker: 7.27" Diameter x 0.43" D; E90 Speaker Strobe: 7.327 Diameter x 2.68" D Operating Temperature Indoor: 33.8°F to 120.2°F (0°C to 49°C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only) 4"square backbox with extension ring prevents wire damage; SBB for surface mount of E70 Wire Connections #12 through #18 AWG Power & General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971, ULC S526 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, Power Supplies or SAFEPATH products, using Wheelock patented sync protocol Frequency Range 400 Hz to 4000 Hz Architects and Engineers Specifications The speaker appliances shall be Wheelock Series E70 or E90 Speakers and Speaker Strobe appliances or approved equals. The speakers shall be UL Listed under UL 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL 1971 for Emergency Devices for the Hearing-Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class A. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range. The strobe shall be of low current design. Where Multi-Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL 1971 at 15/30/75/110cd or 135/185cd for wall mount and 1 5/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series E speakers and strobe speakers shall be red or white. All speaker and speaker strobe appliances shall be backward compatible. UL 1971, UL 1480, ULC-5526, ULC-5541, CSFM, FCC. A1 Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44127 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 www,eaton.com/massnotilicaliov © 2015 Eaton F All Rights Reserved Printed in USA Publication No. TD450024EN Powering Business Worldwide January 2016 Eaton in a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE IAi FIRE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: 0OT3Z - Page lofi 7320-- SPEAKERS Cooper Wheelock Inc. 7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com Model *E50 E60, E-70, E-90, E70, E90, ET70 and ET90 cone type speakers followed by suffix R (red), W (white), S (silver/grey) or X (special). Refer to listee's data sheet for additional detailed product description and operational considerations. 25 or 70 Vrms In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as speakers for use with separately listed electrically compatible fire alarm control units. For indoor use only. These units do not generate a temporal pattern signal. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Rev. 07-30-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division N Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. LAU IM Powering Business Worldwide Universal mounting base Contact cover Jfli) Common base for wall and ceiling with 5 mounting options Technical Data TD450049EN Effective November 2016 Features Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 Audible settings 90, 95, 99 dB Industry leading-8 candela settings on 1 device Wall: 15/1575/30/75/95/110/135/185 ceiling: 15/30/60/75/95/115/150/177 Universal mouting base Ceiling and wall Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Voltage test points for quick troubleshooting and easy spot checking (wall models only) 2 EATON www.eaton.com HN Series HS Series ST Series Environmentally friendly Low current draw Up to 9 models now in 1 appliance drawD 12/24vDc on a single appliance Easy to remember model numbers (D Patented Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ massnotification for current installation instructions. General Notes Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range': All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance UL 1971, UL 464, uLc, cSFM, FM ADA/NFPA/ANSI/OSHA RoHS HN Series HS Series ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24 VDC / 24 FWR Technical Data TD450049EN Effective November 2016 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 16 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 I.4 I U.U)U.0 Ij.tJU I U.UUUU.IU,JU.I,J,JU.IUU '.1.11)5 .1.51)1 U.S.)..) U.I I U Table 2. Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current® at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current® at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current® at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15175 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ® UL max current rating in the maximum RMS current within the listed voltage range (16-33 VOC for 24 VDC units). For strobes the UL man current is usually at the minimum listed voltage itt VDC for 24 VDC units). For audiblen the max current is usually at the maximum listed voltage (33 VOC for 24 VOC units). For unfiltered ratings, nee installation instructions. Table 3. Horn Ratings per UI Anechoic Model legend Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN = Horn A = Red HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering (strobes only) HNC 16-33.0 0.084 0.044 0.022 HS = Horn Strobe AL = Alert Lettering (strobes only) HN 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering (strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W = White Table 4. Specification & Ordering Information Model Strobe Candela Sync w/ OSM or Wheelock Power Supplies 12/24 VDC® Mounting Options Horn Strobes HSR 15/15]5/30/]5/95/110/135/185 X X VMS® HSW 15/1575/30/75/95/110/135/185 X X UMB® HSRC 15/30/60/75/95/115/150/177 X X UMB® HSWC 15/30/60/75/95/115/150/1]] X X LIMB® Strobes SIR 15/15]5/30/75/95/110/135/185 X X LIMBO SIW 15/1575/30/]5/95/110/135/185 X X UMB® STRC 15/30/60/75/95/115/150/177 X X UMB® STWC 15/30/60/75/95/115/150/177 X X UMB® Horn HNR X X VMS® HNW X X LIMBO HNRC I X X LIMBO HNWC I X X LIMBO 12 VDC models feature 15 & 15/75 settings ® UMB = Universal Mounting Base Example 1: STRC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Red, Wall Mount Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: STW-AL = Strobe, White, Wall Mount, Alert Lettering 40 1'. L ui! Example HSR Example. HSWC EATON www.eaton.com 3 Technical Data TD450049EN HN Series Effective November 2016 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from B to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexantm lens. The Series shall be of low current design. Where multi- candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3( audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal )CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM(, ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Fares Boulevard Cleveland, OH 44122 United Slates Ealon.com Eaton Life safety & mass notification solutions 273 Branchporl Ave. Long Branch, NJ 07740 Ealon.com/massnotification St 2016 Eaton All Riglrls Reseved om Printed in USA Publication No. T04500496N Powering Business Worldwide November 2016 Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and FIN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT by Honeywell Agency Listings MEA 457-99-E Vol. V IDP-Minimon Farenhyt IDP-Minimon The IDP-Minimon is a compact and light weight addressable monitor module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Minimon acts as an interface to contact devices, such as waterfiow switches and pull stations. The IDP-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features Single contact monitor Small and lightweight size allows for flexible mounting options Support for Class B wiring Fully supervised Rotary address switches for fast installation Analog communications I Compatibility UL Listed The IDP-Minimon is compatible with the following FACPs: Installation The IDP-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. IFP-2000 I RPS-2000 Intelligent Fire Panel IFP-1000 I ECS Intelligent Fire Panel lFP-100 I ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350279 Rev F Copyright © 20131-loneywell International Inc Other Devices Wiring the 1113112-Minimon Specifications Environmental Physical Operating Temperature: 32°F - 120°F (0°C - 49°C) Height: 1.3" (3.3 cm) Humidity: 10% - 93% non-condensing Width: 2.8" (7 cm) Depth: 0.5" (1.3 cm) Ordering Information Shipping Weight: 1.2 oz (37 g) Miniature Monitoring Module Electrical Operating Voltage: 15-32 VDC Standby Current: 375 pA; 600 pA max (communicating, IDC shorted) End-of-Line Resistance: 47K 2 Initiating Device Circuit Wiring Resistance: 15002 max SLC Loop Resistance: 402 max. Wire Length: 6" mm. This document is not intended to be used for installation purposes. We try to keep our D SILENT product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For MEN more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 = - Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 0559--"f , 5 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, IDP-Monitor, IDP-Minimon, lDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, I DP-Control, I DP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP..RELAYMON.2 *SK..RELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt Addressable Relay Module IDP-Relay The IDP-Relay is an addressable relay module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The OP-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The IDP-Relay contacts can be used for virtually any normally open or normally closed application. Each IDP-Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the IDP-Relay, the relay is triggered by the FACP. Features Two sets of Form C contacts Contacts are rated for a variety of amps (see Specifications) Panel controlled status LED that flashes green in normal state and is solid red in alarm Relay programming is completely flexible—can be mapped to zone conditions Polling LED visible through the cover plate Attractive ivory cover plate Rotary address switches for fast installation SEMS screws for easy wiring UL Listed Relay Contact Ratings Current Rating Max Voltage Load Description Application 3 A 30 VDC Resistive Noncoded 2 A 30 VDC Resistive Coded 0.7 A 70.7 VDC PF = 0.35 Noncoded 0.9 A 125 VAC Resistive Noncoded 0.46 A 30 VDC L/R = 20 ms Noncoded 0.5A 125 VAC PF = 0.75 Noncoded 0.3 A 125 VAC PF = 0.35 Noncoded 2 A 25 VAC PF= 0.35 Noncoded D SILENT KNIGHT by Honeywell Agency Listings MEA 386-02-E Vol II IDP-Relay Compatibility The IDP-Relay is compatible with the following FACPs: IFP-2000 / RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 / ECS Intelligent Fire Panel lFP-100 / ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel Installation Th IDP-Relay mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. P/N 350290 Rev J © 2015 Honeywell International Inc. j CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY. FROM PANEL )cc:.J\:IIII:: OR PREVIOUS DEVICE If any wiring to Terminals 4-10 is Nonpower limited, The CB500 barrier is required. The CB500 includes a Nonpower limited label, which must be placed over the Power Limited terminal information on the name plate label. TO NEXT DEVICE - RELAY CONTROL MODULE 01 k9 e 4T11 @ —4, Relay CommJ 2 T9 TI Normally Clos T NormaIly Op T Relay Comm 0 TO TE NormaIly Clos 10 TENS 0 ONES (+) )L..—' Unused Normally Open 1 NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. Specifications Physical 4.675" H x 4.275' W x 1.4" D Shipping Weight: 6.3 oz (196 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Electrical Operating Voltage: 15 - 32 VDC End-of-Line Resistance: Not used SLC Standby & Alarm Current: .255mA max @ 24 VDC (one communication every 5 sec with LED enabled) Ordering Information Relay Module Accessories SMB500 4" Square Surface Mount Electrical Box CB500 Module Barrier This document is not intended to be used for installation purposes. We try to keep our SILENT product information up-to-date and accurate. We cannot cover all specific applications or K.J'.JIGLIT anticipate all requirements. All specifications are subject to change without notice. For more - information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call Assembled in the by Honeywell 800-446-6444. www.farenhyt.com U.S.A. 9 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL IFNI FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7flu559:Qjj5 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, lDP-Zone-6, SK-Zone-6 six zone interface module, IDP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, I DP-Control, I DP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP..RELAYMON..2 *SKRELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT G by Honeywell Agency Listings 11 MEA RA-1 000 Installation The RA-1000 can be surface or flush mounted. Use the optional trim ring for surface mounts. When flush mounting an electrical box is optional. If using an electrical box, use a 4S, single-gang, or double-gang box. Compatibility The RA-1000 is compatible with the following FACPs: IFP-I000ECS Emergency Communication System with Fire Alarm Control Panel IFP-100ECS Emergency Communication System and Fire Alarm Control Panel lFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel Farenhyt Remote Annunciator RA-1 000 The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels (FACPs). The RA- 1000's keypad and display match the built-in annunciator of the IFP-1000 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence RS-485 interface to panel Operation and appearance is identical to lFP-1000 built-in annunciator Install up to 12 RA-1000s per IFP-1000/ECS or IFP-100/ECS Install up to eight RA-1000s per IFP-50 Support for simultaneous use of multiple RA-1 000s On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Available in red or tight gray Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved MEA P/N 350071 Rev E Copyright © 2014 Honeywell International Inc. RA-1 000 1000 ' a I1FP-1000FACP JfJJJ(3 I) H Up to 12 RA-1000s per system for IFP-1000, • 80-character backlit LCD display IFP-I000ECS, lFP-100 & IFP-IOOECS (4 lines with 20 characters each) Up to 8 RA-1000s per system for IFP-50 • Wiring lengths up to 6000 ft. from the control panel Specifications Physical Height: 7.4" (18.8 cm) Width: 9.1" (23.1 cm) Depth: 1.5" (3.8 cm) Shipping Weight: 2.8 lbs (1.3 kg) Color RA-1000R: Red RA-1000: Gray Electrical Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 ma. from FACP (depending on wire gauge and number of devices on the SBUS) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Approvals NFPA72 UL Listed; L17$59:i5) MEA429-92-E Vol. IX; FM Approved Ordering Information RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. X-1 060,' Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring. For surface mounting. 5860TG Gray Trim Ring. For surface mounting. FlexputT' is a Trademark of Silent Knight Jumpstart® is a Registered Trademark of Silent Knight D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com a Assembled in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. qP Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models 5820, 5820XL, IFP-1 000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, lFP-1000: Control Units 058200P: Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor Intelliknight 5820: Enclosure 5860/5860R/RA-1000: Annunciator 5496: Power Module 5824: Serial/Parallel Interface 5895/5895XL/RPS-1000: Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SD500-ANM : Addressable Notification Module SD500-LIM: Line Isolation Module 5D505-61B: Isolation Base SD-500 SDM: Smoke Detector Module RA-100: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB : Battery Cabinet 5897, 5898: Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. y705559: Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division t Farenhyt Remote Annunciator RA-1 000 The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels (FACPs). The RA- 1000's keypad and display match the built-in annunciator of the IFP-1 000 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence RS-485 interface to panel Operation and appearance is identical to IFP-1000 built-in annunciator Install up to 12 RA-1000s per IFP-1000/ECS or IFP-100/ECS Install up to eight RA-1000s per IFP-50 Support for simultaneous use of multiple RA-1 000s On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Available in red or light gray Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved MEA D SILENT KNIGHT IM by Honeywell Agency Listings 11 ®429-92-E Vol IX MEA APPPOVED RA-1 000 Installation The RA-1000 can be surface or flush mounted. Use the optional trim ring for surface mounts. When flush mounting an electrical box is optional. If using an electrical box, use a 4S, single-gang, or double-gang box. Compatibility The RA-1000 is compatible with the following FAG Ps IFP-I000ECS Emergency Communication System with Fire Alarm Control Panel IFP-IOOECS Emergency Communication System and Fire Alarm Control Panel IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel PIN 350071 Rev E Copyright © 2014 Honeywell International Inc. RA-i000 RA-1000 MUU JFP-1000FACP Ti pplp- Up to 12 RA-1000s per system for IFP-1 000, • 80-character backlit LCD display IFP-I000ECS, IFP-100 & IFP-IOOECS (4 lines with 20 characters each) Up to 8 RA-1000s per system for IFP-50 • Wiring lengths up to 6000 ft. from the control panel Specifications Physical Height: 7.4" (18.8 cm) Width: 9.1" (23.1 cm) Depth: 1.5" (3.8 cm) Shipping Weight: 2.8 lbs (1.3 kg) Color RA-1 DOOR: Red RA-1000: Gray Electrical Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Approvals NFPA72 UL Listed; CSFM 7170-0559: 135; MEA429-92-E Vol. IX; FM Approved Ordering Information RA-1 DOOR Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. RA-1 000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring. For surface mounting. 5860TG Gray Trim Ring. For surface mounting. FlexputTM is a Trademark of Silent Knight Jumpstart® is a Registered Trademark of Silent Knight SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or D KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com Assembled in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0135 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models 5820, 5820XL, IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, IFP-1000: Control Units 058200P: Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor lntelliknight 5820: Enclosure 5860/5860R/RA-1000: Annunciator 5496: Power Module 5824: Serial/Parallel Interface 5895/5895XL/RPS-1000: Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SD500-ANM : Addressable Notification Module SD500-LIM: Line Isolation Module SD505-61B: Isolation Base SD-500 SDM: Smoke Detector Module RA-100: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB : Battery Cabinet 5897, 5898: Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division V DSILENT KNIGHT by Honeywell Farenhyt Remote Annunciator RA-1 000 The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels (FACPs). The RA- 1000's keypad and display match the built-in annunciator of the IFP-1000 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence RS-485 interface to panel Operation and appearance is identical to IFP-1000 built-in annunciator Install up to 12 RA-1000s per IFP-1000/ECS or IFP-100/ECS Install up to eight RA-1000s per lFP-50 Support for simultaneous use of multiple RA-1000s On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Available in red or light gray Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved MEA Agency Listings MEA 429-92-E Vol IX APPROWD IJJJJLJ1 RA-1 000 Installation The RA-1000 can be surface or flush mounted. Use the optional trim ring for surface mounts. When flush mounting an electrical box is optional. If using an electrical box, use a 4S, single-gang, or double-gang box. Compatibility The RA-1000 is compatible with the following FACPs: IFP-1000ECS Emergency Communication System with Fire Alarm Control Panel IFP-100ECS Emergency Communication System and Fire Alarm Control Panel IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350071 Rev E Copyright © 2014 Honeywell International Inc. IFP-1000 FACP A 1" 1T.tT3T RA-1 000 RA-1000 RA-1 000 v " * Up to 12 RA-1000s per system for IFP-1 000, • 80-character backlit LCD display IFP-I000ECS, IFP-100 & IFP-100ECS (4 lines with 20 characters each) Up to 8 RA-1000s per system for IFP-50 • Wiring lengths up to 6000 ft. from the control panel Specifications Physical Height: 7.4" (18.8 cm) Width: 9.1" (23.1 cm) Depth: 1.5" (3.8 cm) Shipping Weight: 2.8 lbs (1.3 kg) Color RA-1000R: Red RA-1000: Gray Electrical Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Approvals NFPA72 UL Listed; CSFM 7170-0559: 135; MEA429-92-E Vol. IX; FM Approved Ordering Information RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. RA-1000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 58601R Red Trim Ring. For surface mounting. 58601G Gray Trim Ring. For surface mounting. FlexputTM is a Trademark of Silent Knight Jumpstart® is a Registered Trademark of Silent Knight D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Assembled in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0135 Page 1 of 2 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models 5820, 5820XL, IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, IFP-1000: Control Units 058200P: Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor lntelliknight 5820: Enclosure 5860/5860R/RA-1000: Annunciator 5496: Power Module 5824: Serial/Parallel Interface 5895/5895XL/RPS-1000: Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SD500-ANM : Addressable Notification Module SD500-LIM: Line Isolation Module 5D505-6113: Isolation Base SD-500 SDM : Smoke Detector Module RA-100: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB: Battery Cabinet 5897, 5898: Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division - -a Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I, ;~ 0 -oo8° SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor a: the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert NM in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 1/22/2021 Supplemental Pages Attached: I PROPERTY INFORMATION Name of property: PACIFIC RIDGE SCHOOL Address: 6269 EL FUERTE STREET CARLSBAD, CA 92009 Description of property: A-3, E, B Name of property representative: - Address: Phone: Fax: E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: JJJ ENTERPRISES Address: 115 MARKET PL, ESCONDIDO, CA 92029 Phone: 760-747-3050 Fax: 760-747-7561 E-mail: INFO@JJJENT.COM Service organization: Address: Phone: Fax: E-mail: Testing organization: JJJ ENTERPRISES Address: 115 MARKET PL, ESCONDIDO, CA 92029 Phone: 760-7470-3050 Fax: 760-747-7561 E-mail: INFO@JJJENT.COM Effective date for test and inspection contract: Monitoring organization: EXISTING VENDOR CIr,k Address: Phone: Fax: E-mail: Account number: Phone line I: Phone line 2: Means of transmission: PHONE LINES Entity to which alarms are retransmitted: CARLSBAD FIRE DEPT. Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: AT FIRE PANEL LOCAITON DESCRIPTION OF SYSTEM OR SERVICE This is a: Z New system 0 Modification to existing system Permit number: coc... 7132C' ( C) NFPA 72 edition: 2016 4.1 Control Unit Manufacturer: FARENHYT Model number: IFP-2100 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds (p.1 of 3) SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120VAC Overcurrent protection: Type: CIRCUIT BREAKER Branch circuit disconnecting means location: LOCKED BREAKER 5.1.2 Secondary Power Type of secondary power: STORAGE BATTERIES Location, if remote from the plant: N/A Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 5.2 Control Unit This system does not have power extender panels 0 Power extender panels are listed on supplementary sheet A R CIRCUITS AND PATHWAYS Control panel amps: 3.0 Amps: 20 Number: In alarm mode (minutes): 5 Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line N/A B Device Power N/A B 1 Initiating Device N/A Y B Notification Appliance N/A Y B 1 Other (specify): N/A N/A N/A N/A 7. REMOTE ANNUNCIATORS Type Location REMOTE LCD MAIN ENTRANCE R ItJlTIATIFJ( flFVICFS Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations N/A Smoke Detectors 49 ADDRESSABLE ALARM PHOTO Duct Smoke Detectors Heat Detectors 1 ADDRESSABLE ALARM HEAT Gas Detectors N/A Waterfiow Switches 1 CONVENTIONAL ALARM ELECTRIC Tamper Switches 2 CONVENTIONAL SUPERVISORY ELECTRIC (p. 2 of 3) SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible 4 WHEELOCK ET-101O-R SPEAKER Visible 9 WHEELOCK STC CEILING STOBE Combination Audible and Visible 26 WHEELOCK E90-24MCC-FW SPEAKER/STROBE SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices 2 HVAC Shutdown 6 Fire/Smoke Dampers 2 Door Unlocking 2 Elevator Recall 4 Elevator Shunt Trip 1 INTERCONNECTED SYSTEMS 0 This system does not have interconnected systems. Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: JJJ ENTERPRISES Title: Phone: 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: JJJ ENTERPRISES Title: Phone: 12.3 Acceptance Test Date and time of acceptance test: Installing contractor representative: Testing contractor representative: Property representative: AHJ representative: (p. 3 of 3) 'p I Copyright 2018 National Fire Protection Association (NFPAS). Licensed, by agreement, for individual use and download on 0711812018 to Columbus City Of. No other reproduction or transatseion in any form perrrdlled without written permission of NFPA€. For inquiries or to report unauthorized use, contact ficen3ing@nfpa.org. This NFCSS All Access subscription expires on September 29, 2018. 72-48 NATIONAL FIRE ALARM AND SIGNALING CODE NOTIFICATION APPLIANCE POWER PANEL SUPPLEMENTARY RECORD OF COMPLETION This form is a supplement to the System Record of Completion. It Includes a list of types and locations of notification appliance power extender panels. This form is to be completed by the system installation contractor at the time of System acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Form Completion Date: i,f22./2i2( Number of Supplemental Pages Attached: PROPERTY INFORMATION Name of property: i9ttt F, C. Al s iL2 / Address: (.Z(? L Afl J'. r,nc C.4 Y 2eç NOTIFICATION APPLIANCE POWER EXTENDER PANELS Make and Model Location Area Served Power Source 2-.' i./. c 14e r-ZAglf ________ • ________________ See Main System Record of Completion for additional information, certifications, and approvals. © 2015 National Fire Protection Association NFPA 72 FIGURE 7.8.2(d) Notification Appliance Power Panel Supplementary Record of Completion. (SIG-FUN) 11711 2016 Edition