HomeMy WebLinkAbout6100 YARROW DR; ; FA070006; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA070006 Job Address: 6100 YARROW DR Permit Type: FALARM Parcel No: Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 1/4/2007 Approved: 1/4/2007 Issued: 1/4/2007 Inspector: Project Title HOMEWOOD SUITES TWO FIRE ALARM INSPECTIONS @ $62/EA Applicant: Owner: DC ASSOCIATES 3671 INDUSTRY AV LAKEWOOD, CA 562-988-8525 Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 D C Associates Inc., Complete Fire Alarm System Material Submittal C17W '(q/ CARLSBAD FIRE DEPARTMENT Homewood Suites 6100 YARROW DRIVE CARLSBAD, CA 92011 DC ASSOCIATES INC. email: rcruz@dcalarm.com 3671 Industry Avenue, Suite Al, Lakewood CA 90712 Phone: (562) 988-8525 Fax: (562) 988-0964 24-Hour Service: (562) 988-8545 . Homewood Suites 6100 YARROW DRIVE CARLSBAD, CA 92011 Manufacturer Device Model # / Description C.S.F.M # SIEMENS MXL FIRE CONTROL UNIT 7171-0067:154 including MXL FIRE CONTROL UNIT 0MM-1 MODULW=E CARDCAGE MKB-2 DISPLAY/KEYBOARD ALD-21 ANALOG LOOP DRIVER MSE-2 ENCLOSURE SIEMENS RCC-3 LCD ANNUNCIATOR 7300-0067:152 WHEELOCK PS-i 2/24-8MP POWER SUPPLY 7315-0785:162 WHEELOCK RSS-24MCC-FW STROBE 7125-0785:141 WHEELOCK MIZ-24 MINI-HORN 7135-0785:115 WHEELOCK AS-24MCC HORN/STROBE 7125-0785:131 WHEELOCK ASWP-2575W-FR WEATHER PROOF HORN/STROBE 7125-0785:131 WHEELOCK MB-G10-24-R SPRINKLER BELL 7135-0785:113 SIEMENS MSI MANUAL STATION 7300-0067:145 SIEMENS FP-1 1 SMOKE DETECTOR 7272-0067:203 include with: SIEMENS ADBX-11 SOUNDER BASE 7300-0067:134 SIEMENS FP-1 1 SMOKE DETECTOR 7272-0067:203 include with: SIEMENS DB-11 DETECTOR BASE 7300-0067:134 SIEMENS FPT-1 1 INTELLIGENT THERMAL DETECTOR 7272-0067:202 include with: SIEMENS DB-11 DETECTOR BASE 7300-0067:134 SIEMENS TRI SERIES INTELLIGENT DEVICES INTERFACE MODULE 7300-0067:146 SIEMENS TRI-136M INTELLIGENT DEVICES INTERFACE MINI-MODULE 7300-0067:146 AAMES DH1224 ELECTROMAGNETIC FIRE DOOR HOLDER 3550-1039:100 SILENT KNIGHT 5129 AUTO DIALER 7300-0067:217 ARROW Model #18JE2-0 16 Awg Stranded Bare Copper 1 Twisted Pair SIEMENS Fire Safety MXL Advanced Protection System ENGI NEER AND ARCHITECT SPECI FICATIONS UUKL Listed for Smoke Control FirePrintTM Application Specific Detection Capacity for over 2,000 Intelligent Input Devices Dynamic Supervision of Intelligent Devices Security Device Monitoring Sprinkler Supervision Intelligent/Analog Detection Circuits, Style 6 (Class A) or Style 4 (Class B) Detector Sensitivity Readout/Printout per NFPA 72 Chapter 7 Style D (Class A) or Style B (Class B) Conventional Initiating Circuits Style Z (Class A) or Style V (Class B) Notification Appliance Circuits Degrade Mode Operation Distributed Processing 80 Character Backlit Alphanumeric Display Thermal Strip Printer Supervised Remote Printer 32 Character Custom Messages Multiple Command Stations Compare System Software Fully Field Programmable Via Laptop Computer Menu Driven Operator Commands Central & Distributed Architecture 800 Event History Logging With On Line & Off Line Reports User Help Screens Multiple Levels of Password Protection Automatic Environmental Compensation for Smoke Detectors One Person Walk Test by Loop. Zone or System Alarm Verification by Device or Zone Logic Controlled Output Functions Time Base Controlled Output Functions Holiday Schedule Citylie/Lease Line Coded Outputs Supervised Serial Annunciator Driver/Input Interface Interactive VDT - Monochrome & Color Color Graphics Option Complies with NFPA 72 NEC 760 Power Limited Circuits (UL 864 Compliant) o 16 Gauge Steel Enclosure ® Listed 864, 1076, ULC Listed FM, CSFM, NYMEA, City of Chicago and U.S. Coast Guard Approved Pre-action Releasing (NFPA 13) FM Approved for Sprinkler & Deluge FM Approved for Intrinsically Safe Applications Halon & FM-200 Releasing Ap- proval (NFPA 12A & NFPA 2001) Multi-Language Display Intelligent Interface to Building/ Process Management Systems Operates as an Interactive Peer with Other MXLs, MXL-10s or MXLVs in a LifeLink Network CXL Command Center Monitoring Pre-Alarm Operation FireFinder Graphics Introduction The MXL is a microprocessor based advanced protection system. Its use of unique multiprocessor "Network" design along with its ability to utilize both analog and conventional detection devices make it the most flexible and reliable system in the life safety field. . The MXL is ideally suited for commercial, institutional and industrial fire detection and notification applica- tions. It complies with the requirements of NFPA Standard 72 and is listed by Underwriters Laboratories under their standard 864. Underwriter's' Laboratories of Canada also lists it for fire applications. It is approved by Factory Mutual as well as CSFM, the City of Chicago and NYMEA for use in those specific locales. In addition to the standard fire applications, MXL is listed by Underwriters Laboratories under the category UUKL for smoke control. MXL can be used as a listed Fireman's Smoke Control Station in high-rise office building, malls and other large structures. It also complies with Uniform Building Code Section 905 requirements for smoke control. CATALOG NUMBER 5000 MXL is approved by the US Coast Guard for marine applications such as ships and oil drilling platforms. It is listed by UL and approved by FM for releasing Halon 1301, FM-200 and pie-action or deluge sprinkler systems. These include foam or water applications. MXL follows the releasing requirements specified in the NFPA Standards 12A, 13 and 2001. Description The basic MXL control unit consists of the following subassemblies: MMB-2 Main Control Board; MPS-6, MPS-12 Power Supply; MKB-2 Annunciator and Key- board; MME-3, MLE-6 or MSE-2 Enclosures. Optional modules which can be installed with the MXL System include: MOM-2/4 Expansion Card Cage; ALD-21 Analog Loop Driver; CRM-4 Controllable Relay Module; NIM- 1W Network/Foreign Systems Interface Module; REP-1 Network Repeater Module; XLD-1 "X" Series Loop Driver; CSM-4 Controllable Signal Module; CZM-4 Conventional Zone Module; PlM-1 Peripheral Interface Driver; CMI-300 CXL Modem Interface Module; PSR-i Remote Power Supply; MXL-VDT Interactive Video Display Terminal; NET-4 Style 4 Network Interface; NET-7 Style 7 Network Interface. Additionally, the MXL system includes option modules MOI-7 System Interface, MOD-16 Output Driven and MID-16 Point Input Module. These can be used to drive graphic annunciators and Fireman's Smoke Control Stations or to monitor foreign systems. The MXL is compatible with a full line of intelligent initiating devices highlighted by the FirePrint Applica- tion Specified Detectors, models FP-ii and FPT-ii. It is also compatible with FireFinder, the NCC series of text and graphic command centers. MMB-2 Main Control Board The function control of the MXL is contained on the MMB-2 Main Control Board. The MMB-2 controls, operates and monitors input device identity, network communications as well as operator commands that are entered through the MKB annunicator/keyboard. All operations are supported by either the MPS-6 or the MPS-12 power supply, eliminating the need for exter- nal power supplies. The MMB-2 is a direct replace- ment of the MMB-i therefore providing total backward compatibility. The MMB-2 provides 2 ALD (Analog Loop Driver) circuits. Each ALD loop can be configured as Style 4 (Class B) or Style 6 (Class A) and can monitor and control up to 60 Siemens Building Technologies, Fire Safety Division intelligent input devices and 60 pro- grammable outputs, either relay, audible or LED. The MMB-2 is equipped with 2 programmable and codable Style Y (Class B) or Style Z (Class A) notification appliance circuits. Each circuit Fire Safety can activate The MMB-2 includes a built-in battery charger and transfer circuit. The charger is microprocessor con- trolled and incorporates a brownout circuit that switches the system to standby batteries during the loss and reduction of the primary source AC. Upon command, the system is capable of displaying the real time, battery voltage, AC voltage and the charge current and other power data on the MKB alphanu- meric display. It also has a 1 amp, 24 VDC output that powers the CZM-1 conventional zone modules. The MMB-2 is designed with a built-in mounting bracket. The MMB-2 mounts directly to the MBR-MP mounting plate for mounting in either the MME-3 or MME-6 backbox enclosure. The MMB-2 can also be mounted in the MBR-2 or MBA-i enclosures. MBR-i requires additional mounting brackets. The on-board 16 bit microprocessor along with non- volatile EPROM and Flash memory allow the system to be custom configured to meet a wide range of customer requirements. The MMB-2 provides a port for connection to a laptop computer allowing for off-line field programming. Complete system configuration can be easily uploaded, downloaded, edited and changes verified using CSGM custom programming software with integrated Compare T11 system software. Program options include but are not limited to smoke detector environmental compensation with two maintenance alert levels, history logging, output control by event, time based control, detector sensitiv- ity, alarm verification by device or zone, 32 character custom alphanumeric messages, system operation passwords and NAC coding. MM B -2 MKB-2 Annunciator/Keypad The MKB-2 mounts on a hinged frame in the MXL enclosure and provides an 80 character backlit LCD alphanumeric annunciator which continuously scrolls to display information concerning system status along with 32 character user defined device messages. When multiple events occur, the MKB-2 displays the last event of the highest priority. Additional data can be viewed by depressing the NEXT key. At any time, the display scroll can be stopped by depressing the HOLD button. Switches are provided for acknowledg- ing fire alarms, supervisories, security conditions, and system troubles. An individual switch is also provided for silencing the system notification appliance circuits. A separate switch is used for resetting the control panel. • up to 1.5 amps of audible and visual notification appliances. A 10 digit numeric keypad is supplied to allow entry of the user passwords, as well as perform specific menu driven operation, programming and maintenance functions. Another series of switches located on the S MK8-2 allows user access to the TSP-40 Thermal Strip Printer, when used. A set of user assignable "Function" keys provide single button access to a variety of system commands. These switches may be used to perform system operation such as "Drill," manual relay control, zone disconnect, etc. Contained on the MKB-2 annunciator are system status indicator LED's which can function even if the main system microprocessor fails. They provide indication of Main Power On, Fire Alarm, Security Condition, System Trouble, Super-visories, System Audibles Active/Silenced and Partial System Disable. The MKB-2 Annunciator communicates with the MMB- 2 Main Control Board through the system network link. MOM-4 Network Option Module Card Cage The MOM-4 Card Cage provides the MXL Main Unit or Remote Units with card slots for option modules. Each MOM-4 supplies connection space for either two full width option modules (ALD-21, CZM-4, NIM-1R, XLD-1) or four half width option modules (CSM-4, CRM-4, CMl-300, NET-7, REP-11) or a combination of one full and two half width modules. MPS-6 Power Supply The MPS-6 is a fully supervised power supply which provides the system with primary DC power. It is rated at 6.5 Amps and is unfiltered and unregulated. It supplies the MXL Control Unit and its expansion modules with power required for normal operation. The unit incorporates a circuit breaker on the primary input and includes a built in AC line filter for surge and noise suppression. The MPS-6 mounts in the MXL enclosure backbox. M MOM-2 Network Option Module Card Cage The MOM-2 provides the MXL main unit, remote units or MXL small enclosures (MSE-2) with card slots for optional modules. Each MOM-2 provides space for One full-width (ALD-21, CZM-4, NlM-i R) or two half-width optional modules (CSM-4, CRM-4, CMl-300, NET-7, REP-11). MPS-12 Power Supply The MPS-12 is a fully supervised power supply which provides the system with preliminary DC power. It is rated at 12 Amps. and is unfiltered and unregulated. It supplies the PSR-1, MMB-2 and their expansion modules with power required for normal operation. The unit incorporates a resettable Circuit breaker on the primary input and includes a built-in AC line filter for surge and noise suppression. The MPS-12 mounts in the MXL enclosure backbox. MOM-2 ALD-21 Analog Loop Driver The ALD-21 is an MXL Network option module which supplies two intelligent analog Circuits utilizing Fire Safety "l' "IL' and FP series intelligent devices. It occupies two addresses on the Network and through the use of a unique communication protocol, devices connected to the ALD-21 circuits are dynamically supervised by the MXL control panel. Up to 60 programmable input and output devices may be connected to each of its two circuits. Each circuit may be wired as Class B (Style 4) or Class A (Style 6). CSM-4 Controllable Signal Module The Controllable Signal Module CSM-4 provides two fully supervised, programmable notification appliance circuits. The CSM-4 supplies two Class B (Style Y) or Class A (Style Z) type output circuits for the supervi- sion and control of listed audible or visual notification appliances such as horns, bells, strobes, etc. Each circuit can provide up to 1.5 amps (24 VDC) of current to power notification appliances. The CSM-4 is also used for extinguishing agent releasing (FM-200, Halon, Pre-Action Sprinkler and Deluge systems). Leased line and municipal tie connections are also possible with the CSM-4. CSM-4 CRM-4 Controllable Relay Module The Controllable Relay Module CRM-4 is designed to provide auxiliary control of building functions such as door holder release, elevator capture, smoke control, lock release, etc. It provides four fully programmable relays. Each relay contains one set of SPOT contacts rated at 2 amps 30 VDC/120 VAC resistive. CRM-4 CMI-300 CXL/MXL Interface Module he CMI-300 is an MXL option module which provides odem communication between an MXL and a CXL command center. This interface board translates signals between the MXL network and a CXL and fully supervises their interconnection. NET-4 Communication Module The NET-4 is a plug-in type module used to provide communication between the Fire Safety MXL and various other MXL Remote Modules. It is designed to plug into an edge connector type slot on the PSR-1 Network Supply. The NET-4 provides NFPA Style 4 type communication. This communication is RS-485 operating at 19.2K Baud. The communication is fully digital. NET-7 Style 7 Network Interface Card The NET-7 is a microprocessor controlled MXL network interface module which allows the wiring of the MXL RS-485 network in an NFPA Style 7 configuration. The NET-7 plugs into a half slot of the MOM-2!4 card cage at the MXL command center (MMB-2) and the PSR-1 or MOM-4 slot at the MXL remote units (MXLR, MXLRV). The NET-7 provides two independent and fully supervised communication paths allowing system operation through an open as well as short circuit. It also isolates the power supplies at each remote unit providing the ability to localize ground fault conditions. The communication operates at 19.2K Baud and is digital. NET-7 REP-1 Network Repeater Module The REP-1 provides the ability to configure the MXLs local or global networks in a star or daisy chain configu- ration. The REP-] provides two Style 4 or one Style 7 RS-485 network circuits. Through the use of the REP-1, the MXLs local network (MXL-MXLR) can be expanded up to 64 nodes. MOI-7 Output/Input Module The M01-7 is an MXL RS-485 Network module which provides a fully programmable serial interface to the MOD-16 output drivers and MID-16 input drivers. When used with the MGD-16's, it provides a serial annunciator output or relay driver. When used with MlD-16, it provides programmable inputs. Each M01-7 can operate up to eight MOD-16s and eight MID-16's simultaneously. Each MOD-16 output and MlD-16 input is independently programmable via the MXL custom software. PSR-1 Remote Power Supply The PSR-1 is a microprocessor controlled remote power supply and battery charger for use with the Fire Safety MXL. It operates in conjunction with either an MPS-6 or MPS-12 to provide 6 or 12 Amps of power for use with various MXL modules. When used with a NET-4 or NET-7 plug-in communication module, the PSR-1 becomes a part of the MXLs internal network. It acts as an interface between remote option modules and the MXL. MOO-16 Output Driver The MOD-16 is an output driver module used in conjunction with the M0I-7 as a part of the Fire Safety MXL System. Up to eight (8) MOD-16s can be con- nected to an MCI-7 interface module. Each MOD-16 provides 16 open collector current sinking outputs rated at 24 VDC, 50mA. MOD-16 outputs are program- mable through the MXL custom software. -1 --- - t_ Lfl - - PIM-1 Peripheral Interface Driver The PlM-1 is an MXL option module which provides a bidirectional isolated RS-232 port for connection to peripheral devices such as printers, CRT's, VDT's, Color Graphics, Alpha-Numeric Pagers and Remote Diagnostics Hardware. The PIM-1 mounts in the MXL Enclosure. It connects to the MMB-2 and provides a screw terminal block for connection of RS-232. A number of supervised and non-supervised formats are available. MID-16 Programmable Input Driver The MID-16 is an input module used in conjunction with the M0I-7 as a part of the Fire Safety MXL System. Up to eight MID-16s can be connected to a single M0I-7 along with eight MOD-16 output driver modules. Each MID-16 provides a non-supervised input which can monitor normally open contact de- vices. Each individual MID-16 input can be separately used as a part of the MXL custom programming logic. These inputs can be individually set for either Alarm, Supervisory, Trouble, Security or Status usage. They can also be configured to provide supervision for lamps driven by MOD-16 outputs. Screw terminals and connectors are provided on the MID-16 modules for interface to monitored devices. S MME-3 is designed for surface of semi-flush mounting and includes various knockouts for wire and conduit entry. The door in the MME-3 set has two cutouts for • either blear tenses, blank plates or grills depending on the application, and contains a key lock. fl MME-3 MXL/V Standard Size Enclosure The MME-3 enclosure set consists of a sheetmetal backbox and door with keylock. The MME-3 can be used for either the MXL System, MXLV Voice Com- mand Console, MXLR Transponder, MXLRV Voice Transponder or Amplifier Equipment (using the MSR-1 Rail Kit). To mount MXL/MXLV modules in the MME-3, the MBR-MP removable module mounting plate is required. Using the MBR-MP mounting plate (1) MMB or (1) PSR-1 and up to 3 expansion cardcages (MOM or 0MM) can be mounted in the MME-3 enclosure. When used to mount MXL amplifiers (EL-410), the MBR-MP is not required, instead up to (3) EL-410 amplifiers may be installed in the MME-3 by using (3) MSR-1 Rail Kits. When amplifiers are mounted in any enclosure always install MDG-1 grills in the door for proper ventilation. MBR-MP MME-3 and MLE-6 MXL Module Mounting Plate The MBR-MP MXL'V Module Mounting Plate is required for use in both MME-3 and MLE-6 enclosures to mount all MXL and MXLV equipment. MBR-MP is not necessary if the MME-3 and MLE-6 enclosures are to be used only for mounting of amplifiers (EL-410). MBR-MP mounting plate bolts to either the MME-3 or MLE-6 enclosures for easy installation on the job site. The MBR-MP also has handles to allow easy transport and mounting. The MBR-MP contains mounting studs for (1) MMB or PSR-1, (1) PlM-, (1) TBM-2, and up to (3) MOM or 0MM cardcages or 2 cardcages and (1) TSP-40 Printer (same mounting studs as the MBR-2 enclosures). The MBR-MP is ordered and shipped separately from the MME-3 and MLE-6 enclosures. MLE-6 MXL/V Large Size Enclosure The MLE-6 enclosure set consists of a sheetmetal backbox and door with two key locks. The MLE-6 can be used for either the MXL system, MXLV Voice Command Console, MXLR Transponder, MXLRV Voice Transponder or Amplifier Equipment (using the MSR-1 Rail Kit. To mount MXLN modules in the MLE-6, the MBR-MP removable module mounting plate is re- quired with the MBR-3MP optionally available for use. Using the MBR-MP mounting plate (1) MMB or PSR-1 and up to (3) expansion cardcages (MOM or 0MM) can be mounted in the MLE-6. If additional cardcages are required, the MBR-31VIP optional cardcage mounting plate can also be installed in the MLE-6 below the MBR-MP The MBR-3MP allows mounting of an addi- tional (3) MOM or 0MM module expansion cardcages. Various combinations of hardware can be installed in the MLE-6. If only amplifiers are to be installed in the MLE-6, no MBR-MP or MBR-3MP plaies are required. Instead up to (5) EL-410 amplifiers can be installed by using (5) MSR-1 rail kits. The MLE-6 can also be used to mount up to (3) MXL cardcages and (2) amplifiers. This configuration would be typical of a remote voice transponder cabinet. In this configuration (1) MBR-MP would be used in the upper half of the MLE-6 to mount the MXL modules, while the lower half would use (2) MSR-1 rail kits to mount up to (2) EL-410 amplifiers. The MLE-6 is designed for surface or semi-flush mounting and includes various knockouts for wire and conduit entry. The door supplied with the MLE-6 set has (3) cutouts for either clear lenses, blank plates or grills, depending on the application. The door also contains (2) key locks - keyed the same. Various combinations of dead front mounting plates are possible with the MLE-6 enclosure. A typical MXLV installation would have (1) MKB-2 at the top, and (2) MHD-3 dead front plates in the middle (for (14) VSM/ VLM/VFM modules per plate) and (1) or (2) MHD-2 lower dead front plates. The MBR-MP is a removable MXLN module mounting plate that allows the enclosure MME-3 or MLE-6 to be sonduit, hipped to the job site for installation of wiring and while the system hardware (electronics) is mounted to the studs on the MBR-M pre-wired, programmed and tested prior to delivery and installa- tion at the job site. This allows for quicker, more efficient system start ups with less chance of the sensitive electronics being damaged while field wiring and conduit are connected to the system enclosure. zH r H MLE-6 MBR-3MP MLE-6 Optional Cardcagi Mounting Plate The MBR-3MP is an optional MXLJMXLV cardcage mounting plate for use exclusively in the MLE-6 enclosure. When installed in the MLE-6 backbox, the MBR-3MP adds the option of mounting up to an additional (3) MOM or 0MM expansion cardcages. MDL-1 Clear Lens • The MDL-1 is a clear Plexiglas' lens which fits in either one of the two openings in the MME-3 enclosure door or in one of the three openings in the MLE-6 enclosure door. One lens is included in the MDL-1 package. MDL- 1 MOB-1 Sheet Metal Blank Plate The MDB-1 is a sheet metal blank plate which fits in either one of the two openings in the MME-3 enclo- sure door or in one of the three openings in the MLE-6 enclosure door. One blank plate is in the MDB-1 package. MIlD-i Upper or Middle Dead Front Panel The MHD-1 is a hinged sheet metal panel which attaches to either the MME-3 or the MLE-6 enclosure backbox. It fits in either the upper or the middle section of the MME-3 backbox or the upper or either of the two middle sections of the MLE-6 backbox. It has an opening with a cover plate for the TSP-40 printer when used and attaches to the backboxes with screw fasteners. When in place it covers and protects modules and wiring, providing dead front construction in that area. MHD-2 Lower Dead Front Panel The MHD-2 is a hinged sheet metal panel which attaches to either the MME-3 or the MILE-6 backboxes. It mounts in the lower section on the MME-3 and on the lower two sections of the MLE-6 backbox. It has no openings and attaches to the enclosures with screw fasteners. When in place, it covers and protects modules and wiring, providing dead front construction in that area. MlID-3 Middle Dead Front Plate for Mounting Switch/LED/Fan Control Modules The MHD-3 is a hinged sheet metal panel that attaches to the MME-3 or MLE-6 backboxes. It fits in either the middle or the upper sections of these enclosures. It has openings for two rows of VSM-1 Switch Modules, VLM-1 LED Annunciator Modules, VFM-1 Fan Control Modules orVSB-1 Blank Plates.. Each row can mount up to (7) modules for a total of (14) modules per MHD-3. The MHD-3 attaches to the backboxes with screw fasteners. It is hinged for easy access to the rear of the modules and inside of the enclosure. MOB-1 I I MHO-3 MH-4 Middle Dead Front Plate for the Switch/LIED/ Fan control M0thiles with Printer Cutout The MHD-4 is a hinged sheet metal panel that attaches to the MME-3 or the MLE-6 backboxes. It fits in the middle section of both enclosures. It has two rows for mounting of VSM-1 Switch Modules, \JLM-1 LED Annunciator Modules, VFM-1 Fan Control Modules or \JSB-1 Blank Modules. Each row has space to mount (4) modules, for a total of (8) modules per MHD-4. The MHD-4 also has a cutout to display the TSP-40 Internal Thermal Strip Printer. The MHD-4 mounts to the backboxes with screw fasteners. It is hinged for easy access to the rear of the modules and inside of the enclosure. When in place, it covers and protects modules and wiring, providing dead front construction n that area. MHO-4 MSE-2 MXL Small Enclosure The MSE-2 is a small MXL enclosure capable of housing an MMB-2 or PSR-1 and MPS-6 or MPS-12. When expansion is required the MSE-2 provides for mounting of either one (1) MOM-2 or OMM-2. MSE-2 is part of the MXL-SS and MXLV-SS packages. MS E -2 MXL-VDT Interactive Video Display Terminal The MXL-VDT is a 14" amber monitor with detachable keyboard. It provides an interactive terminal for secondary display of MXL information, and operation of MXL functions such as Acknowledge, Silence and Reset, as well as arming and disarming devices. It also provides a means for generating system reports such as listing smoke detector sensitivity settings and voltages, battery and power supply voltages and current, and displaying the event log. A printer may be connected to the MXL-VDT. MXL-VDT TSP-40 Thermal Strip Printer The TSP-40 is a thermal strip printer designed for use with the Fire Safety MXL system. It mounts in the MXL enclosure and its printout is visible through a window in the locked enclosure door. Printouts are automatically spooled on a take-up reel for easy record storage. MSR-1 Rail Kit The MSR-1 is a System 3 type rail kit which fits into eithe.r the MME-3 or the MLE-6 enclosures. The MSR-1 .comes with a U-bracket and a Z-bracket. It allows modules such as the EL-410 amplifier, PS-35 Power Supply, BC-35 Battery Charger, MOI-7 I/O Interface, MID-16 Input Driver, MOD-16 Output Driver, PS-5A Power Supply, SYS3-MFFO for mounting the D2300CP Fiber Optic Interface modules or the CCU Pager interface, or any other System 3 type module required to be mounted in the MME-3 or the MLE-6 enclosures. When used in the MME-3 enclosure (3) MSR-1 Rail Kits can be installed to mount up to three rows for up to (3) EL-410 amplifiers. When used in the MLE-6, up to (5) MSR-1 Rail Kit rows can be installed to allow mounting up to (5) EL-410 amplifiers. When the MLE-6 enclosure is used with the MBR-MP mounting plate to install MXL or MXLV equipment, up to (2) MSR-1 Rail Kit rows can also be installed in the MLE-6 for mount- ing of either (2) EL-410 amplifiers or some complement of System 3 type mount modules. S MSR-1 TSP-40 S S RCC-1 Remote Command Console The RCC-1 is a remotely located MXL annunciator display module. The RCC-i contains an 80 character LCD display and control keypad (MKB) and a PS-51\17 network interface. RCC-is can be located anywhere that control or annunciation is required. RCC-1 can be programmed for display only or can provide display and system control. If a PIM-i is added to the RCC-1, remote printers, VDT or graphics computers can be located throughout a facility. RCC-t PIM-2 Parallel Printer Interface The PIM-2 is an MXL or CXL parallel printer interface module. PIM-2 connects to PIM-i to allow MXL connection and supervision of any EDP UL listed printer. PlM-2 PAL-1 UL Listed Parallel Printer The PAL-1 is a UL listed supervised parallel system printer for MXL or CXL. The PAL-i connects to the PIM-2 and PIM-i to provide MXL with a UL listed parallel printer that is supervised. lCP-6 Intelligent Control Point The ICP is a field mounted output module capable of being programmed to be either a remote bell or horn, speaker or telephone zone. The ICP communicates with the MXL via the ALD loop. UM-1 Line Isolator Module The LIM-1 is a short circuit isolator module for use on the MXLs analog loops. The LlM-i is capable of providing Style 4 or Style 6 wiring of ALD loops. Multiple short circuit isolators can be used on a single ALD loop to prevent loss of protection in the event of a short circuit. IN- OUT OUT- PS-5N7 5 Volt Power Supply/Network Interface The PS-51\17 is a 5V power supply and MXL local network interface module. The PS-51\17 is an integral part of the RCC-1. The PS-51\17 can be used to provide a Style 4or Style 7 network interface for either a remote transponder for MXLV with either TBM-2, ACM- 1 and VSM-iNLM-1NFM-1 or to drive 0MM-1 and associated MXLV cards. I] PS-5A 5 Volt Power Supply The PS-5A provides 5 Volts for powering the MO 1-7. It obtains its power from the 24-volt supply in the MXL system. Both the M0I-7 and the PS-5A mount on system 3 rails. They can also be mounted external to the MXL control. They typically drive remote graphic annunciators or monitor foreign systems and devices. DM-MXL, ROM-PC The RDM-MXL in combination with the RDM-PC provides the ability to call up an MXL system to check on the system status. The RDM-PC connects a remote computer to the MXL equipped with the RDM-MXL. The RDM-PC initiates a call to the MXLs RDM-MXL module. The RDM-MXL answers the call The RDM-PC identifies itself with the login name. As a built-in security measure, when the login name is recognized by the RDM-MXL, it then hangs up and initiates a call back to verify the login and password. Once the login and password is verified, the operator is on-line with the MXL. The operator can list system status, alarms, troubles, supervisories, and/or security events CCU/M NM-W Network Interface Module The N1M-1\jV allows the interconnection or networking of up to 63 MXL systems. The NIM-1VV provides an RS-485 communication path in either Style 4 or Style S 7 wiring configurations. The NIM-1W allows MXLs to have interpanel logic and communicate in a peer to peer fashion. The NIM-1W can be programmed via CSGM logic as a Foreign System Interface to commu- nicate with external building management systems. -' [Ii5IY FireFinder NCC-G - Network Color Graphics FireFinder is a PC based color graphics command center designed, for use with the LifeLINK network and provides full control and annunciation for a LifeLINK network of up to 63 MXL-IQ or MXL systems. The NCC-G is used to monitor and control alarms, troubles, security, supervisory and all system events from one of many MXL series systems. The NCC-G maintains an extensive history log of all system events and has S extensive report generation capabilities. User program- mable function buttons allow site specific control functions. Multiple NCC-Gs may be connected to a LifeLINK network. PC ordered separately. The model NCC-GL is a color graphics command center for a single, stand-alone MXL system. It has all of the features of the NCC-G. FireFinder NCC-G CCU/M Alphanumeric Pager Interface The CCU/M is a ancillary module that connects to the PlM-1 to transmit MXL status information in text message format to an alphanumeric pocket pager. The CCU/M can be connected to an existing phone line and can dial out to a pager using its onboard modem to transmit information via a paging service. The CCU/M can also connect directly to an existing on-site paging S system. Through programming the CCU/M can send different types of events to different pagers. Up to 8 different messages can be sent to pagers directly from the CCU/M. Alarms, Troubles, Supervisory, Security, Arm/Disarm, Status Points, Audible Status, and Reset can be directed to all or only certain alpha- numeric pocket pagers. Model Number Description Part Number CZM-1 Conventional Zone Module 315-09072I ILI-1/1H/1 AllAH Intelligent Ion Detectors 31 -0-09272i ILP-1iIPLT-1 Intelligent Photo Detectors 315-09259L LT-1 Intelligent Heat Detectors 315-09333E LI-i 8/11BH Intelligent Ion High Vei. 315-093234 ILP-2 FirePrinCA Application Specific Detection 315-095029 MSl-108/208 Intelligent Manual Station . 315-093329 MS-MI Intelligent Metal Manual Station 315-092169 TRI-881860/BBR Intelligent Monitor Module single/dual and with array) 315-093315 TRl-861M Intelligent Mini-Monitoring Module 315-094547 ICP Intelligent Control Point 315-092471 LlM-1 Line Isolator Module 315-092135 PP -Il Intelligent Fireprint-' Detector 315-095921 TRl-S/D/R Intelligent Monitor Module 3115-096242 For further details refer to MXL Manual P/N 315-092036 MMB2 Electrical Specifications for Analog Loop Devices (TB2. 1-4 and T83, 1-4) 1. Electrical Ratings: Supervisory: 24VDC peak, 106mA max. Alarm: 24 VDC peak, lOSmA max. (60 devices in alarm) All wiring must be in accordance with Article 760 of NEC or local building codes. Only Cerberus Pyrotronics devices may be used. (See Table 1) A maximum of 60 devices in any combination may be connected to a single analog loop. No end of line device required. Both circuits are power limited to NFPA 70/NEC. Each detector or group of detectors, requires a two wire circuit of minimum 18 AWG thermoplastic fixture wire enclosed in a conduit or minimum 18 AWG limited energy shielded cable without conduit, if permitted by local codes. Total circuit resistance must not exceed 100 ohms. Maximum capacitance: 0.4pF between + loop and - loop 0.8pF between + loop and chassis 0.8pF between - loop and chassis 7 T-tapping is not allowed on Class A (Style 6) loops 0 MMB-2 CZM-1 Power AUX power is available on TB5 terminals 9-12 All wiring must be in accordance with Article 760 of NEC or local building codes. AUX power is power limited to NFPA 70/NEC 760. Electrical Ratings: 18-31 VDC, 1A max. MMB-2 Notification Appliance Circuits (T85. 1-4 and TB5, 5-8) These notification appliance circuits are for alarm notification appliances only (NFPA 72 Local). For Municipal tie (NFPA 72, Chapter 4) or Leased Line (NFPA 72, Chapter 4), use model CSM-4. All wiring must be in accordance with Article 760 of NEC or local building codes. Both notification appliance circuits are power limited to NFPA 70/NEC 760, Electrical Ratings: Supervisory 18-31 VDC, 12mA max Alarm 18-31 VDC, 1.5A max. End of Line Device: EOL 2.2K, 1/2W (PIN 140-820380) Line Resistance: Not to exceed 3 ohms max For compatible notification appliances see 315-096363 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7170-0067:154 Page 1 of 1 - CATEGORY: Control Unit (High-Rise) LISTEE: Siemens Building Technologies Inc., Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932 Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652 DESIGN: Model MXL and MXL-IQ fire alarm control units. Coded or noncoded; local, auxiliary, remote and central station proprietary service; automatic, manual waterflow, releasing service and sprinkler supervisory service when used as a remote station (protected premise) unit or proprietary fire receiving unit. Refer to listee's data sheet for additional detailed product description and operational considerations. Basic components: MMB-11, *..2 , *..3115MB..12 22, *..32 Main Control Board MKB-1 1, 21, .42 *..51 *..62 Keyboard/Annunciator Panel MPS-6, -12 Power Supply CRM-4 Relay Module CSM-4 Signal Module CZM-4 Conventional Zone Module BTX-.1, BP-61 Battery Set Module MSE-21, 32, *.3M2 Enclosure *MSE3MD Enclosure Door Silent Knight 5128, 5129 Dialer/DACT (Listing No. 7300-0559:120) 1 - For use with Model MXL only. . 2 - For use with Model MXL-IQ only. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for high rise application when used in conjunction with listee's listed Model VoiceCom system (CSFM Listing No. 6911-0067:173) and separately listed compatible initiating and indicating devices. See (CSFM Listing No. 7300-0067:172) for optional control unit accessories. Refer to listee's Installation Instructions Manual for details. *These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Rev. 01-02-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any Claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. .Date Issued: JUNE 9 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager S Fire Safety MXL/MXLV Remote Annunciator/Keyboard w/Enhanced Display ENGINEER AND ARCHITECT SPECIFICATIONS Remote MKB for Display and Control Full Command Keyboard 6" LCD Display Automatic Backlight o Displays 8 Events and System Status Programmable Function Keys Partial System Disable LED Power LED Alarm, Supervisory, Trouble And Security LED's Audibles Active/Silenced LED with Local Audible Menu Driven Operator Commands User Help Screens Printer Control Keys Display Control Keys Tactile Membrane Switches With Audible Feedback Metal Enclosure with Key lock Door Restricts Keypad Access @ ULC Listed Description The RCC-3 is a full control remote display/keyboard center for use with the Siemens Fire Safety MXL and MXLV systems. The RCC-3 includes its own enclosure with a lockable door. It provides a complete operator interface including a 6" ¼-VGA backlit LCD for display of all system informatiori.The LCD shows up to eight events in sequential order by priority and includes event type, the custom message for the event, and an indica- tion if the event has been acknowledged. Up and down arrow keys allow the user to scroll through the list of events, and a separate key will display more information about the highlighted event, including device type and location and the time of the event. The display will also give a system status line, indicating how many of each type of event is present on the system. The RCC-3 provides a set of keypads used to execute S system commands such as Acknowledge, Silence, Reset as well as disarming of devices for maintenance and generation of system diagnostic reports. From the keypad the operator is able to change the sensitivity setting of smoke detectors, check device voltages, obtain system power reports, disarm input and output devices and manually toggle remote and local relays. All com- mands are menu driven and a Help key allows the operator to get further explanation of the command structure. Operator actions are prompted so training is kept to a minimum. The RCC-3 also provides a set of 12 programmable functions keys.The keys can be configured to activate functions such as Drill, Fan Shutdown, Door Release, etc. LEDs on the RCC-3 in conjunction with a local audible signal, indicate active conditions such as Alarm, Supervi- sory, Trouble and Security. The LEDs flash and the audible sounds until events are acknowledged. Additional LEDs indicate Audibles Silenced, Power On and Partial System Disable.The Partial System Disable LED illuminates whenever an input or output device is disarmed. CATALOG NUMBER 5078 Multiple RCC-3s can be used in the system each provid- ing full control of the MXL system. Up to four multiline displays (MKB-5, MKB-6, or RCC-3) can operate in a fully supervised mode, each with independent printer driver capability built-in. The RCC-3 keypad and display are covered by a clear lens as a part of the enclosures lockable door. This equipment is approved for operation over the temperature range of 0°C to 49°C. Ordering Information Model Number Descriplion Part Number KC-3 Rrrot mnrard Ceo Jar wf Eohaoed DrapLa 5-B4 C-3F )emoe ( meori cier w/ Erthaoced C(p(av 50O-B4SaS JCC-3C RCC mr Er ai't&d OiaIav (Franth/EngJisF( 500-&4885? CC-3FC )CC oc Enoaroea DispIa lFrchEo)isn. 5O-645S5 Siemens Building Technologies Fire Safety Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel, (973) 593-2600 FAX: (973) 593-6670 Websire: www.sbtsiertiens.com/fis 11/03 SM 5F5-IG Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario Canada L67 5E4 Tel: (905) 799-9937 FAX: (905) 799-9858 November2003 Ne', issie LISTING No. CATEGORY: USTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM USTNG SERVICE 7300-0067:152 Page 1 of 1 Misc. Devices/Control Unit Accessories Siemens Building Technologies Inc., Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932 Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652 Control unit accessories as listed below. Refer to listee's data sheet and control unit's installation instructions for additional detailed product description and operational considerations. PSR-1 NET-4, -7, -7M MOI-1/MOl-7 MOD-16 VCP-25 FT-30 1/C/CL, FT-302/CICL FJ-303, PT-303, -304, FJ-303SS, -304, -304SS CP-2297 CP-2341 PAL-1 MID-16 VDT ICP, ICP-86 PIM-2, RSE-1 RCC-1, RCC-1F, RCC-2, *RCC3, *RCC3F CP 7537-394 CP 7554-001, CP-7574, CP-7574T SCD-19M, -19TM, SCD-21M, -21TM MXL-G/CXL-G CPP LLM-1 CP-7585-33/-66/-1 00/-P 133 SCD-550, -550T, -550-DOS AlC-4Z, NCC-1F Remote Power Supply Communications Interface Voice and Annunciator Driver Output Driver Remote Indicating Device Zone Output Module Remote Telephone Station Remote Telephone Station Remote Telephone Station Signal Line Suppressor Supply Line Suppressor Printer Input Module Video Display Terminal Intelligent Control Point Module Printer Interface Module Remote Command Center Computer Monitor Monitor Graphic Interface Multiplexer Leased Line Module Computer Computer Interface Card INSTALLATION: MARKING: APPROVAL: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Rev. 10-28-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or 4j recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. • Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager POWERPATH TM NAC POWER SUPPLIES Series PS-12/24-8CP Series PS-I 2/24-8MP wroo; AD ;H111 e p i n ci People Take ALOn S Description POWERPATHTM Series PS-12/24-8CP and PS-12/24-8MP are power limited 8 amp power supply/chargers used to expand the supervised power capability of a fire alarm control panel (FACP) for notification appliance circuits (NAC). The PS-12/24-8CP provides up to 200 milliamps of continuous auxiliary output that can be used for control functions during alarm (or up to 60 milliamps for 60 hour battery requirements). The PS-12/24-8MP provides up to 3.5 amps of auxiliary output that is available only during nonalarm condition for such applications as door holder systems. Both models provide regulated and filtered 12 or 24 VDC output to four (4) Class "B" or two (2) Class "A' circuits. Each Class "B" circuit has a rating of three (3) amps with a total output of up to eight (8) amps. Each Class A" circuit is rated at three (3) amps. Two (2) Class 'A" or Class "B" inputs from an FACP and two (2) dry contact inputs are provided to trigger the outputs. The units accept either 12 or 24 VDC inputs and provide 12 or 24 VDC outputs. Both units support a full 8 amps of notification power even if the battery is in a degraded mode and only AC power is connected. POWERPATHT111 Series PS-12/24-8CP and PS-12/24-8MP are compatible with all Wheelock 12 or 24 VDC Life Safety Notification Appliances and with their Patented BUILT-IN SYNCHRONIZED MODE feature, they can control and operate all of Wheelock's Synchronized Notification Appliances, including silencing audibles while maintaining strobe activation. (Batteries Not Included) Features Approvals Approvals Include: UL Standard 864, California State Fire Marshal (CSFM), (New York City (MEA), Factory Mutual (FM), Chicago (BFP) See Approvals by model in Specification and Ordering Information Compliant with NFPA 72 Inputs - Compatible with 12 or 24 VDC FACP 115 VAC @50/60 Hz or 240 VAC @50/60 Hz Two 12 or 24VDC NAC Initiating Circuits from host panel Two "Dry" contact input circuits Accepts 2 Class "A" or 2 Class "B" NAC circuit inputs Additional activation options are: NC contacts or open collector of a transistor Outputs 8 amperes rated supply current @ 12 or 24 VDC - Filtered and regulated power supply outputs Class 2 rated power limited outputs - Dip switch selectable options Field selectable 12 or 24 VDC outputs - 4 Class "B" or 2 Class "A" or 1 Class "A" and 2 Class ."B" Notification Appliance Circuits) - Each Class "B" output has a maximum rating of three (3) amperes - Each Class "A" output has a maximum rating of three (3) amperes Code 3 (Temporal) option Steady output option Copyright 2004 Wheelock, Inc. All rights reserved. Outputs Cont. Built-In Wheelock Synchronization Protocol Input and output synchronization (including pass through) Supervision FACP NAC supervision steered to either input #1 or #2 - Common input and output trouble circuit - Input and output LED indicators AC fail supervision (Form "C" contacts rated @ 1 an 'p 24 VDC or 115 VAC) Battery presence and low battery supervision (Form "C" contacts rated @ 1 amp @ 24 VDC or 115 VAC) Ground fault detection 4 latching LED's for NAC trouble annunciation Power Not Battery Dependent. Full 8A even if battery is degraded Automatic switch over to standby batteries when AC fails Supports sealed lead acid or gel type batteries Fused battery protection - Thermal and short circuit protection with auto reset - Supports both 7AH or I2AH batteries in the same cabinet (Cabinet Size: 16" H x 12.25" W x 5" D) Auxiliary Power Up to 200 mA continuous with PS-12/24-8CP Up to 3.5 amps nonalarm with PS-12/24-8MP Normal Mode (Class B) OUT I-4 INOUT SYNC - WNEELOCSSYECT TE.POAL F NS INPUT SELECT 10 NEST APLI NCE OR EOL - RET' C POWERPA P 5w9 ______ OUT TO NEXT APPLIANCE OR EOLR (2.2K OHMS) TO NEXT APPLIANCE OR EOLR (2.2K OHMS) TO NEXT APPLIANCE OR EOLR (2.2K OHMS) TO NEXT APPLIANCE OR EOLR (2.2K OHMS) Normal Mode (Class A) OUT 1-4 .1 INOUT SYNC OIJT1 IN 1 . WHEELOCK SYNC - TEMPORAL TO NEXT APPLIA ICE INPUT SELECT F OR EOLR RETI OR RETU Fq= TO PACP ourf (CLASS A) C POWERPA H P ouT_____ _ _ OUT___ POWERPATHTM Operating Modes (refer to Installation Manual): Normal Mode: Provides constant 12 VDC or 24 VDC output upon initiation by a voltage to input IN or IN2 or by a contact opening on DRY1 or DRY2. The unit returns to standby mode when the input is deactivated. Wheelock Sync Mode: Provides signals for synchronization of patented Wheelock audible and strobe notification appliances. Audibles can also be silenced in this mode while the strobes continue to flash. ln>Out Sync Mode: Accepts a coded signal or synchronization signal on the input to provide a coded output or synchronized output. This signal may come from a FACP, another POWERPATH or a Wheelock SM or DSM synchronization module. Caution: Do not use strobes on coded output circuits. Temporal Mode: Codes the output voltage in a code-3 temporal pattern to drive audible appliances such as horns, bells or chimes. Caution: Do not use strobes on coded output circuits. [I S S rcnirecs ana The power supplies shall be Wheelock POWERPATH11 Series PS-12/24-8CP or PS-12/24-8MP, or equivalent. The units shall be stand alone power supplies intended for powering fire alarm notification appliances via their own Notification Appliance Circuit(s) (NAC). The units shall be UL 864 Listed for power limited operation of their outputs and comply with NFPA 70 (NEC), article 760 The power supplies shall support a full 8A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supplies shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact" closure. The units shall be 8 ampere, 12 or 24 VDC, regulated and filtered, supervised remote power supply! chargers. The power supplies shall provide a full 8 amperes of current and shall not be battery dependent. They shall operate over the voltage range of 8 to 33 VDC or FWR. The primary application of the units shall be to expand fire alarm system capabilities for additional NAC circuits to supportADA requirements and to provide auxiliary power to support system accessories or functions. The power supplies shall provide four Class "B', two Class 'A", or two Class "B' and one Class "A' NAC circuit(s). The PS-12/248CP units shall also supply up to 200 mA of auxiliary power that is available during both nonalarm and alarm. The PS-12/24-8MP units shall also supply auxiliary power of not less than 3.5A at 24 VDC during nonalarm. The power supplies shall be capable of charging batteries of up to 12 ampere hours per NFPA 72(1999). Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class "B" applications or 3 amperes each for Class "A". The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supplies shall provide independent loop supervision for either Class "A' or Class "B" FACP NAC circuits and shall have the capability to "steer' all alarm or trouble conditions to either incoming NAC circuit. The units shall have common output terminals. The power supplies shall be powered from a 120 VAC or 240 VAC source with a current consumption of 5 amperes max. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 100 mA max. The cabinet dimensions shall be 16" H x 12.25" W x 5" D. A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLY I N G THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS. CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE , A N D SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Specifications and Ordering Information Model Number Order Code! Input Voltage/Current Approvals I UL I MEA J CSFM FM PS-12/24-8CP 3047 120/220 VAC @ 50/60 Hz; 5.0 amps max. X I x PS-12124-8MP 3046 120/220 VAC @ 50/60 Hz 5.0 amps max. X X X X Output NAC Circuits Output Voltage/Current XApproved *= Pending Four (4) Class "B' 12/24 VDC @ 3 amps per Circuit I Two (2) Class "A' or 12/24 VDC @ 3 amps per Circuit .4 One (1) Class "A" and Two (2) Class "B" 12/24 VDC @ 3 amps per Circuit (Class "A") 12/24 VDC @ 3 amps per Circuit (Class "B") Standby Current I 0.060 Amps Alarm Current 0.100 Amps Total NAC Current 8 Amps Max. Standby Batteries Standby Time Alarm Output Aux Output 1 Total Amps/Minutes PS-12/24-8MP Aux Output PS-12124-8CP [(uses two (2)12 VOC batteries in series) 24 Hours 24VDC/12AH ___. 8Amps/15 Minutes 8Amps/15Minutes 3.5A dung nonalarm , 24 Hours I_8Amps/iS Minutes 60Hours _8Amps/iSMinutes 200 mA 60 mA 200 mA 60 mA 60 Hours 1 12VDC/12AH NOTE: Due to continuous development of our products, specifications and offerings are subject to change without no t i c e in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY National Sales Office Made in USA Distributed By: 800-631-2148 Canada 800-397-5777 E-Mail: lnfo@wheelockinc.com -. 273 Branchport Avenue Long Branch, NJ 07740 • TEL: 732-222-6880 FAX: 732-222-2588 S900011/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM USTNG SERVICE S LISTING No. 7315-0785:162 Page 1 of 1 CATEGORY: Power Units LISTEE: Wheelock Inc. 273 Branchport Ave., Long Branch, NJ 07740 Contact: *Brian Lampe (800) 631-2148 x6389 FAX (732) 222-5607 DESIGN: Model. PS-12/24-8MP, PS-12124-8CP, *ps..24.8Mc Indicating Circuit Power Supply. Unit is a regulated 12 or 24 VDC power supply/charger used for supervision and expanded power driving capability of up to four notification appliance circuits (NAC). Units may be connected to any 12VDC or 24VDC fire alarm control panel. The unit is intended for use with listee's Model MPEOL end-of-line resistor. Replacement printed circuit board assembly part number PSX-12/24-8MP, PSX-12/24-8CP and *psx..24..8Mc Model PS- 4CA Class A Card for use with Model PS-24-8MC. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/240 VAC, 50/60Hz input: 12 or 24 VDC output INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a power supply unit for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: For fire alarm use, the secondary (standby) power supply shall supply energy during power loss to operate a protected premises, central station, or proprietary system for 24 hours or an auxiliary or remote station system for 60 hours in the normal condition, followed by not less than 5 minutes of alarm as required by code. Two 12V batteries are required for 24V operation, one 12V battery is required for 12V operation. *Rev. 06-23-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: JUNE 23, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager New Look lagF' Series RSS - Series RSSP RSS Round Multi-Candela Indicator (bottom of Strobe Lens) Features /1 Hinc Peopie Take Act•on SERIES RSS & RSSP SINGLE & MULTI-CANDELA STROBES & STROBE PLATES DESCRIPTION Wheelock's patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or Wheelock's Patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/11 0cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-12/24-8CP and PS-12/24-8MP Power Supplies with Wheelock's Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4' backboxes or for surface mount use with Wheelock's SBL2 surface backbox. For Weatherproof Series RSS See Datatsheet S9004 Copyright 2004 Wheelock, Inc. All rights reserved. Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADAJNFPAIUFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 751110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15130175195cd or 1151177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" using filtered (DC) or unfiltered VRMS input voltage Synchronize using Wheelock's sync modules or power supplies with built-in sync protocol Fast installation with IN/OUT screw terminals using #12 to#18AWG wire NOTE: All CAUTIONS and WARNINGS are identified by the symbolA All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971 Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 F to 120 F (O C to 49 C) and maximum humidity of 93% (± 2%). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP - Wall Mount RSS - Ceiling Mount RSSIRSSP 241575W 24MCW 24MCWH 24MCC 24MCCH Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 1 RSS/RSSP 24VDC Models 12 vdc UL max RSS/RSSP J * RMS current ratings are per UL average RMS method. UL max current Wall Mount rating is the maximum RMS current within the listed voltage range (16-33v 121575W for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at 0.152 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, 0.255 see installation instructions. I Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. NSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. E STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR TERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INST A L L A T I O N , APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIO U S INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. S Wiring Diagrams 11 [SERIES RSS/RSSP APPLIANCE FROM ___ TO NEXT PRECEDING APPLIANCE APPLIANCE. SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC SYNC CIRCUIT 0- OUT -IN 1 RSS RSS RSS FACP0_ 0+ AUDIBLEj I O U -IN2 RSS RSS RSS STROBE NAC CIRCUIT RETURN BE/PLATE ASSEMBLY LE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT I FROM APPLIANCE PRECEDING t OR EOLR APPLIANCE. SYNC MODULE, POWER SUPPLY OR FACP + 0 STROBE AUDIBLE SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F I+STROBEi - STROBE Strobe A NAC :)~~RSS C Circuit 0 I P 2EOLR JAudible SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 PF Strobe NAC Cir. ,•4yC DSM #2 A Strobe NAC Cir. Sync RSS RSS C / \ / DSM #3 P Sync - RSS RSS Strobe NAC Cir. DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12/24.8CP or PS-12124-8MP AS REX OUTPUTS F 1-4 4-CLASS ' C 25S A B' OR AS 1 EOLR AS . I JRSS STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM PRECEDING + + TO NEXT .APP UANCEOR APPLIANCE OR ECLR FACP - - 1 1 - - - FROM + - +T0 E' PRECEDING STROBE OR STROBE. SYNC - - 1-1 1 r - - - - EOLR MODULE POWER SUPPLY ORFACP + - I STROBE APPLIANCE Series PS-12124-E1VIP detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For • wiring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12/24-81VIP. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA). Underwriters Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province. district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Enaineers Soecifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shalt meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-impaired) for indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of IT' circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and hall have the same electronic circuitry as the Wheelock Series RSS. he Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable ettings and shall be rated per UL Standard 1971 at 15/30/75/llOcd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. he selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 isting with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelocks SM. DSM Sync Modules or Wheelock's PS-12'24-8CP and PS- 12124-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single-gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shalt be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. v101e. Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE M oun ing Ions Square Round Agency Approvals UL MEA CSFM FM - BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,D,E,F.G,H,J,N,O.R,X Square X X X X X RSS-24MCW-FW 19401 1 X - X 1 15/30/75/110 X - - X B,D.E,F,G.H.J,N,O.R,X Square X X X X X RSS-241575W-FR 7471 1 X - X 15(75onAxis) X - X - B,D,E,F,G.H,J,N,O.R,X Square X X X X X S-241575W-FW 7788 X - X 15(75onAxis) X - - X B,D,E,F,G.H,J,N,O.R,X Square X X X X X -121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,F.G.H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X I - X 15(75onAxis) - X - X B,D,E,F.G,H,J,N,O.R,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X B,D,E,F.G,H,J,N,O.R,X I Square X X X X RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O.R,X Round X X X X RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G.H,J,N,O,R,X Square X X X X * RSS-24MCCHR-FW 3463 - X X 115/177 X - X B,D.E,F.G,H,J,N.O.R,X Round X X X X RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E.F.G.H.J,N,O.R,X Square X X X X * RSSWP2475WFR* 9013 X - X 180@ 77-F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP2475WFW** 3034 X - X 180@ 77-F X X - X B.D,E.F,G,H,J,N.O,R,X Square X X X * RSSP-121575W-FR 7798 X - X 115(75onAxis) - X X I - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D.E,Z Square X X X X X RSSP-241575W-FR 7793 X - IX 115(75onAxis) I - - X - D,E,Z Square X X X X X RSSP-24MCWH-FR 9482 X I X 1 135/185 1 X - X - B.D,E.F,G,H,J,N,O,R,X Square X X X * J * All models sync with Wheelock SM, DSM or PS-12/24-8CP or PS-12/24-8MP. *PENDING # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY I Made in USA NATIONAL SALES OFFICE Distributed By. 1-800-631-2148 Canada 800 397-5777 AffPS UVA'"I'A E-mail: InfowheeIockinc.com 11 , lit httD://www.wheelockinc.com WHEELOCK, INC. • 273 BRANCHPORT AVE LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S0410 03/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM USTNG SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave. Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 24100 24100 24100 24100 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, *Rss..24McwH *RSS24MCWHR *RSSP24MCWH *RSS.24MCCH *Rss.. 24MCCHR, and *RSSP..24MCCH. Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 =16-33VDC/FWR Candela 155cd, 157515/75cd on axis, 30=30cd, 7575cd, 110110cd (Wall) RSS-24MCW, RSSP-24MCW--Selectable 15cd, 30cd, 75cd or 1 10cd RSS-24MCC, RSS-24MCCR and RSSP-24MCC - Selectable 15cd, 30cd, 75cd and 95cd *Rss.24McwH *RSS.24MCWHR *RSSP..24MCWH - Selectable 135cd, 185cd *Rss.24MccH *RSS..24MCCHR *RSSP..24MCCH - Selectable ll5cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix —W, wall mount only. Models with suffix —C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Hpnç Peol: .11:a! \CtOfl I r pij Description: Wheelock Series MIZ piezoelectric Mini Horns are compact electronic alarm appliances that are listed under UL Standard 464 for Audible Appliances in Public Mode Fire Protection Systems. The Series MIZ-24S models provide a field selectable Continuous or Code 3 horn tone when connected directly to a fire alarm control panel. They can also provide a synchronized code 3 horn tone using the Wheelock SM, DSM Sync Modules or PS-12124-8CP and PS-12/24-8MP Power Supplies. The series MlZ appliances are attractive, offer high sound output along with low current draw and are ideal for alarm signaling in individual rooms, apartments, hotels, motels and offices. Color choices of red or off-white will blend with any decor. Applications: Individual Rooms Apartments Hotels Motels Offices Wiring Diagrams (for all models) FROM PRECEDING TO NEXT APPLIANCE OR FACP APPLIANCE - ____ ______ OR EOLR + 7I' + - SERIES MIZ.24S MINI HORN TEMPORAL (CODE 3) OR CONTINUOUS TONE Features: Approvals include: UL Standard 464, California St Fire Marshal (CSFM), New York City (MEA), Fact Mutual (FM), and Chicago (BFP) Field selectable settings for Temporal (Code 3) or Continuous Horn Synchronized code 3 horn when used with Wheelock's Sync Module Designed to meet or exceed NFPNANSI standarc Convenient mounting to any standard single-gang box Beauty plugs to cover mounting screws No additional trimplate required for flush mounting Fast installation with In/Out screw terminals using #12 to#18AWG High sound output with low current draw Available in red or off-white color Specifications and Ordering Information Order Mounting Agency Approvals Model Description Code Options** MEAl CSFMII FM BFP MlZ-24S-R 8485 24 Volt Red B X X X X * MLZ-24S-W 8484 24 Volt White B X X X X * . 'PENDING **Refer to Data Sheet S7000 for Mounting Options. General Notes: Mini Horn models are Listed for indoor use with a temperature range of 320 F to 1200 F (0° C to 490 C) and maximum humidity of 93% RH ±2%. Rated Input voltage (either filtered DC or unfiltered full-wave-rectified FWR): 16-33 VDC (for 24 VDC MIZ-24S models) Copyright 2003 Wheelock Inc. All rights reserved. Architects and Enaineers Soecifications The notification appliance shall be a Wheelock M!Z-24S audible appliance or approved equal. The Notification Appliance shall be electronic and shall have field selectable settings for Temporal (Code 3) or continuous horn and support coded systems operation. The anechoic sound pressure measurement on Temporal (Code 3) setting shall be 87 dBA minimum at 24VDC. The anechoic sound pressure measurement on Continuous Horn setting shall be 87 dBA minimum at 24 VDC. Operating voltages shall be 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provision for standard reverse polarity type supervision and IN/OUT wiring using terminals that accept #12 to #18 AWG wiring. The appliances shall be mounted indoors and mount on standard single-gang electrical backboxes requiring no additional trimolates or adaoters. Table 1: UL Listed Models and Ranges Reverberant dBA Anechoic dBA Regulated Average Per UL 464 @ 10 ft @ 10 ft Model UL Current* RMS Continuous! Code 3 Continuous. Code 3 Mounting Options Voltage (AMPS) dBA dBA dBA dBA 24 VDC 0.025 832 788 879 879 B MlZ-24SH UL max* 0.026 858 1 813 906 897 B RMS current ratings are per UL average RM method. UL max current rating is the maximun RMS current within the listed voltage range (16-33' for 24v units). For strobes the UL max current i usually at the minimum listed voltage (16v for 24 units). For audibles the max current is usually a the maximum listed voltage (33v for 24v units). Foi unfiltered FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identified by the symbolA. All warnings are printed in bold capital letters. AWARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. 4111~NARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P84408) AND "GENERAL ORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED VOLTAGE RANGE. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION .3 YEAR WARRANTY NATIONAL SALES OFFICE 8O0-83i2 148 Canada 800-397-5777 . E-Mail: Info@wheelockinc.com W http://www.wheelockinc.com 273 BRANCHPORT AVENUE • LONG BRANCH, NJ 07740 • TEL Distributed By: 732-222-6880 FAX: 732-222-2588 S1700 07104 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . US flNGSERVCE LISTING No. 7135-0785:115 Page 1 of 1 CATEGORY: Audible Devices LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Models MIZ-12 and MIZ-24 series horns. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Rev. 06-13-2006 'c This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. • Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager -'- -I H&ping People Take :ction SERIES AS SI NGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCES SERIES AH AUDIBLES Description Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. S Strobe options for wall mount models include 1575cd or Wheelock's patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/11Ocd, or the high intensity MCWH strobe with field selectable 135/1 85cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 1 5/30175/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-i 2/24-8CP and PS-1 2/24-8MP Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. For Weatherproof Series AS, See Datasheet S9004 Copyright 2004 Wheelock Inc. All rights reserved. SERIES AS SERIES AH T2XILI Multi-Candela Indicator (bottom of lens) Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information. ADAJNFPAJUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi-Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/1 77cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL 'Regulated Voltage Range' using filtered DC or unfiltered FWR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires NOTE: All CAUTIONS and WARNINGS are identified by the symbol A . All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Genera/Notes Strobes are designed to Rash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series AS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32' F to 120' F (0' C to 49' C) and maximum humidity of 93% (± 2%). Series AH-24 horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Series AH-24WP audible appliances are listed under UL Standard 464 for indoor/outdoor use with a temperature range of -31,17 to 150'F (-35'C to 66'C) and maximum humidity of 95%. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Input Voltage VDC I Regulated Voltage Strobe candela (Cd) As_24Mcw 24 16.0-33.0 15/30/751110 As-24MccH 24 16.0-33.0 115/177 A5-241575W 24 16.0-33.0 15 (75 on As) AS-121575W 12 8.0-17.5 15 175 on Axis) As-24Mcc 24 16.0-33.0 I 15i30,75i95 AS-24MCWH 124 16.0-33.0 I 135/185 fAswP.2475w 24 16.0 -33.0 75 @ -31'F Table 2: dBA Ratings for 12 VDC and 24 VOC Series AS/AN 12 and 24 VDC Audible Description Volume Reverberant dBA I Anechoic Per UL464@l0ft. dBA@ 10 ft. High Continuous Horn Medium Low 91 88 83 99 95 90 High Code 3 Horn Medium Low 87 84 79 99 95 90 Table 3: Average RMS Current Audible 24 VDC Models AH-24 Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd l5cd 30cd 75cd j hOod 135cd 185cd l5cd 30cd 75cd lh5cdl 177cd° 24 vdc 1 0.062 High(99)dBA UL max' 0.080 0.100 0.121 0.080 1 0.102 0.150 1 0.194 0.088 . 0.125 0.200 0.267 0.250 1 0.320 0.088 0.1141 0.165 0.205 I 0.355 0.480 1 0.095 10.13810.221j0.285 0.250 2 0.320 0.355 0.480 24 vdc 0.033 f 0.080 0.060 1 0.0841 0.132 0.173 0.230 0.305 I 0.066 0.09210.145 0.18610230 . 0.305 Med(95)dBA UL max' 0.043 0.107 0.074 . 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0201 0269f 0.340 0.465 24 vdc . 0.017 0.072 0.052 0.076 0.121 0.158 0220 0.295 1 0.056 0.082 0.132 0.173! 0.220 0295 1: Low(90)dBA UL max' 0.021 0.100 0.068 0.105 0.182 i 0.245 I 0.335 0.460 0.074 i 0.113 0.198 0.2631 0.335 0.460 I Audible i I Wall Mount 12 VDC Models Audible Strobe AH-12 AS-121575W I RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16- 33V for 24v units). For strobes the UL max current is usually at the 12 vdc 0,163 0.260 High (99) dBAUL max' 0.192 0.320 f I III III IUI IIOU VUILage kI LIV LII 'V UI 1110/. rl.JI UUIUI0 LI IdA LUI 1 I IL is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. 12 vdc 0.076 0.195 W'v led (95)d5A UL max* 0.108 0.275 12 vdc 0.039 0.175 Low (90) dBA UL max'1 0.058 1 0.265 SERIES AS APPLIANCES SYNCHRONIZED WITH OSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE Z] A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83947) SERIES AS-24MCW, (P84023 AND P84024 ) S E R I E S AS SINGLE CANDELA, (P83519) Seles AH, (P83641) Series AM-WP AND "GENERAL INFORMATION" SHEET (P82380) ON THES E P R O D U C T S . T H E S E DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. T H E S E M A T E R I A L S CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDIN G : TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUIT S . ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCU L A T E C U R R E N T DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATE D CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROP E R I N S T A L L A T I O N , APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY D A M A G E A N D SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTAL L A T I O N O F T H E S E PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. FROM TO NEXT + APPLIANCE - OR EOLR OR FACP PRECEDING APPLIANCE I SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE Strobe A NAC AS C Circuit *Audible AS 3U 13 PAudqible:9 NAC Circuit SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES Audible NAC Cit. 0SM#1 - Strobe NAC Cir. 4SYtC JLLt _J F rt-I'-Jrl Audible NAC Cii' I OSM #2 A Strobe NAC Cirf I Sync + AS I I C Audible NAC Ci4 j OSM E:::i:1 Strobe I IlY I IIA NAC Is OSM Interconnecting wiring shown. Maximum of twenty (20) Wiring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED S SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12/24-8CP and PS-12/24-8MP IM OUTPUTS COLA 1.4 4-CLASS A OR AS 455 C 2-CLASS L1J ASS Se,,es PS-I5J24.8CP _AS or PS. 12)24-OMP For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM . F o r w i r i n g information on the power supplies refer to Installation Instructions P84515 for PS-12124-8CP and P84333 for PS-12/24 - 8 M P . Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, op e r a t e d , m a i n t a i n e d and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or mor e o f t e n a n d i n accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and t e s t i n g must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection A s s o c i a t i o n ( N F P A ) . Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, s t a t e , c o u n t y , province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not li m i t e d t o , a l l appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). [1 Architects and Enaineers SDeciflcations The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelocks SM, DSM Sync Modules or Wheelock's PS-12/24-8CP or PS-12/24-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Specifications and Ordering Information Model Order Code Strobe Candela Non-Sync Sync w/SM OSM PS-12124.8CP or PS 12124-SMP 24 voc 12 VOC wall 0 M unt OU Ceiling Agency Mounting Options Approvals UL MEA CSFM FM BFP AS 24MCW FR 9024 18,30175,110 - x x X A 808 FOIl J J OR x x x x x x AS 24McN FW AS 24MCW11 FR 9025 3468 15/30/75/110 135/185 X X X X X X X X A 80 8 FOIl J NOR X A 80 E FOIl J NOR X X X X X X X AS 24MCWH F/V 3469 135/185 X X X A 3D E 'OH J 'JO RX )( X X X * AS-241575W-FR 7405 15(75onAxis) X X - X X ASDEFGIIJ'IORX X X X X K AS 121575WFR 7410 1(75onAjas} K X K X ABDEFGHJNOR.X X X X X X AS 24MCC FR 3161 15,30/75/95 X X X K A 30 E FOIl J NOR X X X X X * AS24MCC FW 3162 15/30/75/95 X X X K ABDEFOHJ'JORX X X X X * AS24MCCHFW 3467 115/177 X X X x ASOEFOHJNORX K X X K ASWP 2475W FR 9012 75 @ -31-F I X X X X I (see Data Sheet S9004) X X X X X ,kI-124R AH24W AHI2R AI12W 7892 7893 7891 7894 X X K K X X X X X X X X X K X K X X K X ABDEFOHJ\IORX ABDEFGHJNORX ASDEFGI-IJ"JORX ABDEFOHJ'JORX K X K 1 X X X X K K K X K X X X X X K X X AH24WPR 7416 K K K X K K K X K K AHI2WPR 7415 K X K K X K X K X X *PENDING Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. *For Weatherproof Series AS/AH specifications see data sheet S9004. —Refer to Data Sheet S7000 for Mounting Options. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: lnfo@wheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY Made in USA S -. ...... Distributed By: WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 FAX: 732-222-2588 S810001/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE ARE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM USTNG SERVCE LISTING No. 7125-0785:131 Pagel of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Models AS-1215,-2415,-1230,-2430,-121575,-241575,-2475 and -24ll0 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listees data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:1 10cd MCW: Selectable 15cd, 30cd, 75cd, 11 Ocd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 1 77cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with 0 suffix -C are for ceiling mount only. *Rev. 06-13-06 Listing No. 7125-0785:131 Page 2 of 2 S MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 orDSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listees Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 . Authorized By: DIANE K. A REND, Senior Deputy Program Manager Ceiling Mount SERIES RSSWP -' jflc-tQchc L (T ADA - -- ,. . ... r 1 Z7' iij Hang Peoe Take Act•on5 DESCRIPTION: \Nheelock's Weatherproof Strobe. Audible Strobe. Audible Horn and Multitone Strobe appliances have an extended temperature range of -31'F to 150'F (-35'C to 66'C) that will satisfy virtually all outdoor, severe environment wall and ceiling applications. All strobes are Indoor/Outdoor UL Standard 1638 Listedand rated for 180 candela on axis @ 77°F (25'C) and 75 candela at -31°F (35°C) with low current draw. Wall Mount The Wheelock Weatherproof Appliances are designed for while meeting or exceeding the latest requirements of NFPA . . . MTWP maximum performance, reliability, and cost effectiveness SERIES 72 (National Fire Alarm Code), UL Standard 1638 (Standard Mounted to for Visual Signaling Appliances), and UL Standard 464 IOB-R (Standard for Audible Signaling Appliances). Series RSSWP Strobes, Series ASWP Audible Strobes and Series AHWP Audibles may be synchronized when used in conjunction with the Wheelock SM and DSM Sync Modules or the PS-12/24-8CP and PS-12/24-8MP Power Supplies with Patented Sync Protocol. The Series MTWP is a true 4-wire appliance. The strobe portion can be synchronized as stated above. The multitone portion cannot, but it can be connected to a coded fire alarm system. Weatheroroof Strobe Series RSSWP Is UL Standard 1638 approved for Indoor/Outdoor use. The appliances use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum visibility and reliability for effective visual signaling. The Series RSSWP mounts to a Series WPSBB Weatherproof Backbox. Weatherproof Audible Strobe and Audible Series ASWP and AHWP Is UL Standard 1638 and UL Standard 464 approved for Indoor/Outdoor use and offer a field selectable choice of continuous horn or temporal pattern (Code 3) when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Additionally, the audible has three (3) selectable dBA settings of 99, 95, and 90 dBA in both tones and, when synchronized, may be silenced while maintaining strobe activation. The Series ASWP mounts to a WPBB Weatherproof Backbox while the Series AH mounts to a WBB Weatherproof Backbox. Weatherproof Multitone Strobe and Multitone Horn Series MTWP and MT..12/24 Is UL Standard 1638 and UL Standard 464 approved for Indoor/Outdoor use and offers a field selectable choice of 8 nationally and internationally recognized alerting signals. Additionally, the audible has 2 installer selectable sound output levels: Standard and high covering a range (depending on selected signal) of 76-94 dBA reverberant. The Series MTWP is a true 4 wire appliance. The Strobe .portion can be synchronized or non-synchronized. The multitone (audible) portion cannot be synchronized, but it can be connected to a coded fire alarm system. The Series MTWP and the MT-12/24 mount to a series lOB Backbox. Copyright 2004 Wheelock. Inc. All rights reserved, SERIES AHWP Mounted to WBB-R is , SERIES RSSWP L!1 Mounted to WPSBB-R SERIES ASWP Mounted to WPBB-R (Series MTWP Ceiling Mount not shown) Features Approvals include: UL Standard 1638 and 464, California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Table 8 Designed to meet or exceed NFPA,/UFC/ANSI 117.1/ OSHA Part 29, 1910.165, and ADA requirements UL Standard 1638 and UL Standard 464 listed with extended temperature range of -31° to 150°F (-35°C to 66°C) 24 VDC with new UL "Regulated" Voltage Range: of 16-33 VDC using filtered DC or unfiltered FWR voltage Note: The Series MT-12/24 voltage range is 10.5 - 15.6 VDC (for 12V) and 20-31 VDC (for 24V) o Sync/Non-Sync in each product. Note: The audible portion of the Series MTWP and MT-12/24 is non sync only Synchronize with Series SM, DSM Sync Modules or PS-12/24-8CP and PS-1 2/24-8MP Power Supplies with built-in patented sync protocol Selectable dBA settings Selectable alert signals IN and OUT wiring termination that accepts two #12-18 AWG wires at each terminal ° Inputs are polarized for compatibility with industry standard reverse polarity supervision Table 1: Average Current* for Series RSSWP and Strobe in MTWP Strobe 75 cd @ -31°F (-35°C) Regulated Voltage Range * Avg. Current 24.0 VDC UL Max* RSSWP 16.0 - 33.0 VDC 0.094 0.138 4hF- able 2: Average Current* (AMPS) For Series ASWP# High dBA Medium dBA Low dBA Voltage Setting Setting Setting (99) dBA (95) dBA (90) dBA 24.0 VDC 0.128 0.105 0.098 UL Max* 0.168 0.155 1 0.150 "Audible and Visual combined. Table 3: Average Current* (AMPS) for Series AHWP Voltage AH-24WP Voltage AH-I2WP AH.24WP Hi/Med/Low AM-12WP Hi/Med/Low 24.0 VDC 1 0.062/0.033/0.017 1 12.0 VDC 0.163/0.076/0.039 UL Max* 0.080/0.043/0.021 UL Max* 0.192/0.108/0.058 Table 4: dBA Ratings for Series ASWP & AHWP Reverberant dBA 1 Anechoic dBA Per UL 464 @ Description Volume loft. 24 VDC 24 VDC High 1 91 99 Continuous Med 88 _95 Horn Low 82 _90 High 85 99 de 3 Med 82 _-95 rn Low 75 _90 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (1 6v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. . ii iji'o ano ri'iiriu are loentiTlea by the symbol & All WARNINGS are printed in bold capital letters. àWARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS, OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: . Wheelock UL Standard 1638 Strobes are designed to produce 30-62 flashes per minute over the Regulated Voltage Range. If used in an indoor application, UL Standard 1638 strobes must be operated at a minimum of 20 VDC to meet the NFPA-72 flash rate of ito 2 flashes per second and ADA Guideline flash rate of 1 to 3 flashes per second. Wheelock Weatherproof Appliances are designed to operate over an extended temperature range of -31F to 1507 (-35C to 66C) and all candela ratings represent minimum effective strobe intensity based on UL Standard 1638. Maximum humidity of 93% RH ±2%. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". AWARNING: CONTACT WHEELOCK FOR THE CURRENT 'INSTALLATION INSTRUCTIONS" AND GENERAL INFORMATION' SHEET (P82380) ON THESE PRODUCTS. THE INSTALLATION INSTRUCTIONS ARE AS FOLLOWS: P84135 FOR SERIES RSSWP, P83957 FOR SERIES ASWP, P83641 FOR SERIES AH-WP. P84150 FOR SERIES MTWP AND P824671 FOR SERIES MT-1 2124-R. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS. INCLUDING: Total current required by all appliances connected to system secondary power sources. Fuse ratings on notification appliance circuits to handle peak currents from all appliances on those circuits, Adding, replacing or changing appliances will effect current draw. Recalculate current draw to insure that the total average current and total peak required by all appliances does not exceed the rated capacity of the power source or fuses. Composite flash rate from multiple strobes within a person's field of view. The voltage applied to these products must be within their "REGULATED VOLTAGE RANGE". Use strobe only on circuits with continuously applied operating voltage. Do not use strobes on coded or interrupted circuits in which the applied voltage is cycled on and off as the strobe may not flash. Conductor size (AWG), length and ampacity should be taken into consideration prior to design and installation of these products, particularly in retrofit installations. Table5:AverageCurrent*(AMPS)for 24VSeriesMTWP Audible Strobe Tone 24.0 VDC UL Max* 24.0 VDC 1 UL Max*- Standardl High IStandard l _High 0.108 0.053 1 0.104 1 0.091 0.094 0.075 0.098 0.104 0.057 0.138 Horn 0.033 0.074 0.044 Bell 0.018 0.040 0.024 MarchTime 1 0.033 10.0671 0.038 Code3Horn 1 0.026 0.069 0.035 Code3Tone 1 0.026 0.061 ,0.035 1 SlowWhoop 0.028 0.0691 0.037 1 Siren 0.027 0.080 0.036 1 Hi/Lo 1 0.020 0.0441 0.026 1 Table 6: dBA Ratings for Series MTWP and MT-12/24 Tone Standard 1 MTWP MT-12/24 1160 240 330200I240 High setting k/DC VDC VDC VDC VDC 105120 VDC VDC Standard !848790182 85 82) 85 Horn I- j HighSetting 8992,94i88 91 88 91 Standard 76 80 83 75 79 75 79 B :High Setting 83I8688i82 8582!85 March Time Standard 80 84 87 79 82 79 82 High Setting 86 89 91 1 85 88 85 88 Standard 17918386175 7975179 Code3Horn High Setting i 85 88 . 90185, 85 85 85 Standard I 76 80 82 75 75 75 I 75 Code3Tone , f.HlghSetting 81 185 86 79) 82.79 82. Standard 81 85 87!82 82 82 82 Slow Whoop High Setting 1 87 90 92 88 1 88 88 88 Standard i 81 84 87 82 82 82 82 ;Siren .:High Settingi 86 89 92 85) 88 85 88 Hi/1..o Standard 771818417917979179 :High Setting 83 86 .89 82 85 82 85 I SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE I IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. FROM ) ____ ______ + TO NEXT PRECEDING + APPLIANCE RED kPPLIANCE I ____ - OR EOLR K)R FACP SLACK STROBE AUDIBLE I SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12/24 I APPLIANCES I FROM + TO NEXT I PRECEDING APPLIANCE I APPLIANCE OR OR EOLR I FACP Wiring Diagrams SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED !A DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE SYNC0 NAC - CIRCUIT e OUT 0uOUT1 I I 0 IN 1 RSS I EE1 0MINUS 1 LI AUOIBL1 Z ØMINUS I AS- Ø+IN2 RSS ROBE NAC O+OUTZ CIRCUIT RETURN SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP MTWP 01 0 ____ _____________ 0 Slrcbe Sync CCircuit Module NAC ;Fl Audbie or PSI2'2e.8 I Power Circue - FACP Supply NAC ;2®1 I Note: Strobe circuit requires constant volts Model Number Code Order Strobe cd @77F Strobe cd @ -31F dBA Input Voltage Mounting Outdoor Back Box & Order Code - Agency Approvals Strobe LII MEA CSFMJFMIBF RSSWP-2475W-FR 9013 180cd j 75cd - 24 VDC I WPSBB-R (9751) X X X 'X * RSSWP-2475W-FW 3034 180cd j 75cd - 24 VDC I WPSBB-W (3033)1 X X X X RSSWP-2475C-FR 4338 180cd L 75cd 24 VDC I WPSBB-R(9751) X X X X RSSWP-2475C-FW 4446 180cd ] 75cd - 24 VDC I WPSBB-W (3033) X I X I X I X * AudibleStrobe ASWP-2475W-FR 9012 1 180cd I 75cd 1 90/95/991 24VDC I I WPBB-R(9014) X X X X X ASWP-2475C-FR 4251 180cd I 75cd 190/95/991 24VDC I I WPBB-R(9014) X X X X X MultitoneStrobe MTWP-2475W-FR 8420 180cd 75cd 76-94 24VDC M IOB-R(5046) X X X X MTWP-2475C-FR 4457 180cd 75cd 76-94 24 VDC M 106-R(5046) X X X X MTWP-2475C-FW 1 4458 180cd 75cd 76-94 24 VDC M IOB-W(5047) X X X X * HornslAudibles AH-24WP-R 7416 N/A I N/A 190/95/991 24VDC I K I WBB-R(2959) X X X - X AH-12WP-R 7415 N/A I N/A 90/95/99 12 VDC I K I WBB-R(2959) X X X - X MT-12/24-R 5023 N/A N/A 76-94 12/24 VDC M 10B-R (5046) X X X X Speaker Strobe _X ET70WP-2475W-FR 9077 180cd 75cd 77-93 24 VDC M I0B-R(5046) X X X ET70WP-2475C-FR 4452 180cd 75cd 77-93 M IOB-R(5046) X X * EI70WP-2475C-FW 4454 180cd 75cd 77-93 _24VDC 24 VDC M I0B-W(5047) X X _X X * For more information on the ET70WP Appliance, see Specification Sheet S9006. 0 ARCHITECTS AND ENGINEERS SPECIFICATIONS The Weatherproof Strobe appliances shall be Wheelock Series RSSWP-2475 strobes or approved equals for wall and ceiling mount applications. The Series RSSWP shall meet and be listed for UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor! Outdoor use. The strobe appliances shall produce a flash rate of 30-62 flashes per minute over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® ens. The strobe shall be rated at 75cd and shall operate over an extended temperature range of -31°F to 150°F (-35°C to 66°C). All inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel. When synchronization is required, the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-12/24-8MP Power Supply with built-in, patented sync protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The Series RSSWP shall be mounted only to the WPSBB-R Backbox. The Weatherproof Audible Strobe and Audible appliances shall be Wheelock Series ASWP-2475 Audible Strobes for wall and ceiling mount applicaitons and Wheelock Series AHWP Audible Horns for wall mount or approved equals. The Series ASWP and Series AHWP shall meet and be listed for UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use. The strobe appliances shall produce a flash rate of 30-62 flashes per minute over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The strobe shall be rated 180cd @ 77°F (25°C) and 75cd at -31°F (-35°C) and shall operate over an extended temperature range at -31°F to 150°F (-35°C to 66°C) and be listed for maximum humidity at 95% RI-f. All inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The Series ASWP shall be mounted only to the WPBB-R Backbox while the Series AHWP shall only be mounted to the WBB-R Backbox. The weatherproof audible strobe appliances shall be designed for two-wire operation and shall provide either a continuous or temporal (Code 3) tone when constant voltage from a Notification Appliance Circuit (NAC) of the Fire Alarm Control Panel (FACP) is applied. They shall be designed so that the audible signal may be silenced while maintaining strobe activation. When synchronization is required, the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-12/24-8MP Power Supply with built-in, patented sync protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The Weatherproof Multitone Strobe and Multitone Audible appliances shall be a Wheelock Series MTWP and MT-12/24 or equivalent. The Series MTWP shall meet and be listed for UL Standard 1638 (Standard for Visual Signaling Appliances) for indoor/outdoor use. The strobe portion of the appliance shall produce a flash rate of 30-62 flashes per minute over the listed voltage range of 20-31 VDC and shall incorporate a Xenon flash tube enclosed in a rugged Lexan® lens. IThe strobe shall be rated 180cd @ 77°F (25°C) and 75cd at -31°F (-35°C) and shall operate over an extended temperature range at -31°F to 150°F (-35°C to 66°C) and be listed for maximum humidity at 95% RH. All inputs shall be polarized for compatibility with industry standard reverse polarity of circuit wiring by a Fire Alarm Control anel. The audible portion of the Series MTWP as well as the Series MT-12/24 shall provide eight field selectable alarm signals. The FIgnals shall consists of: Horn, Bell, March Time, Code 3 Horn, Code 3 Tone, Slow Whoop, Siren and Hi/Lo. Tone selection shall be by a durable dip switch assembly. Clips or Jumpers are not acceptable. The appliance shall provide two output Sound levels: Standard and High dBA. The range of dBA shall be 75 to 94 dBA. The Series MTWP shall have an operating voltage of 24 VDC (nominal) while the Series MT-12/24 shall operate at either 12 or 24 VDC (nominal) using filtered power or unfiltered power (full wave rectified). Both models shall have provisions for In/Out field wiring using terminals that accept #12 to #18 AWG wiring. When synchronization is required, the Series MTWP shall be compatible with the Series SM and DSM Sync Modules or with the Series PS-12/24-8MP Power Supply with built-in, patented sync protocol. Note: The Strobe portion of the Series MTWP may be synchronized. The audible portion of the appliance cannot. The audible portion of the appliance can be connected to a coded fire alarm system. The Series MTWP and the Series MT-12/24 shall be mounted only to the IOB-R Backbox. Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION MADE IN THE USA NATIONAL SALES OFFICE 3 YEAR WARRANTY 800.631.2148 I Canada 800-397-5777 I E-Mail: lnfo@wheelockinc.com http://www.wheelockinc.com I 273 BRANCHPORT AVENUE • LONG BRANCH, NJ 07740 'TEL 732-222-6880 'FAX: 732-222-2588 S900402106 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:11 Ocd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. *Rev. 06-13-06 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. C *Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 40 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2007 He1png Take F, C!'' : :( I \ :•" SERI ES MB MOTOR BELLS Description Wheelock's Series MB Motor Bells provide a better engineered motor bell for fire and life safety alarm systems. The Wheelock Series MB Bells include higher dBA, low current draw, built-in trimplate for semi-flush mounting, low frequency aluminum shells, and low RFl noise. The motor for Series MB Bells is a durable, high torque permanent magnet motor selected for its high performance and long life. r-1 SERIES MB RSSP REMOTE PLATE These DC vibrating Series MB Motor Bells are offered in 6" and 10" shell sizes in both 12 and 24 VDC models. Series RSSP Sync/Non-Sync retrofit plates are used in conjunction with the Series MB Motor Bell when combination appliances are required. The Series RSSP retrofit plates are available with either Multi-Candela or single candela strobes and easily mount to a 4" square or Wheelock SBL-2 backbox. All Series RSSP strobe appliances meet or exceed the requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard for Accessible and Usable Buildings and Facilities), ADA (Americans with Disabilities Act) and UL Standard 1971 (Signaling Devices for the Hearing Impaired). The Series RSSP retrofit plates may be synchronized when installed with the Wheelock Series SM, DSM, Sync Modules or the PS-12/24-8CP or PS-12/24-8MP Power Supply with Wheelock's patented sync protocol. Wheelock's synchronized strobes offer an easy way to comply with ADA requirements concerning photo- sensitive epilepsy. Ordering Information Features Approvals include: UL Standard 464, Factory Mutual (FM), Califorr State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) Meets OSHA 29 Part 1910.165 High sound output with low current draw Low frequency aluminum shells for better audibility through walls, doors and other structures 6" and 10" shell sizes in 12 or 24 VDC models Integral RFl suppression to minimize included noise on the NAC circuit Mounting options for surface, semi-flush, outdoor, and concealed conduit installation Built-in trimplate makes semi-flush mounting simpler and less expensive Screw terminals permit fast in-out field wiring of #12 to 18 AWG wir Polarized for DC supervision of NAC circuits Operates on filtered or unfiltered DC For combined audible (bell) and visual signaling, convenient retrofi plate assemblies are available with Multi-Candela or Single cande strobes (Refer to Fire Alarm Products Catalog for Series RSSP Syn Non-Sync Strobes specifications and technical information) Model Number Order Shell Code Size Input Voltage (VDC) Average RMS Current UL Max* dBA @ 10 Ft. Mounting Options MB-G6-12-R 3942 1 6" 12 0.060 0.090 0.090 0.040 0.040 I 92 0.090 0.090 0.040 0.040 D.E,J.K.N.O.P,R,S I MB-G6-12-S 4221 6" 12 0.060 MB-G6-24-R 3941 1 6" 24 0.030 MB-G6-24-S 4222 6" 24 0.030 MB-G10-12-R 3944 10 " 12 1 0.060 I MB-G10-12-S 4223 10" 12 1 0.060 1 MB-G10-24-R 3943 10" 24 0.030 MB-G10-24-S 4224 10" 24 1 0.030 NOTES: Typical dBAat 10 feet is measured in an anechoic chamber. For bells all 12 VDC models are UL rated for 9.0 to 15,6 VDC and all 2' VDC models for 18.0 to 31.0 VDC. RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (3v for 24v units). For unfiltered FWR ratings, see installation instructions. Copyright 2005 Wheelock. Inc. All rights reserved. Architects and Engineers Specifications The alarm appliances shall be Wheelock Series MB vibrating Motor Bells or approved equal. They shall be UL Standard 464 Listed for Fire Protective Service. Shells shall be aluminum in 6' or 10" diameter. Sound output at 10 feet shall be 92 dBA. The bells shall incorporate a permanent magnet motor and suppression circuitry to minimize RFI. They shall include a built-in trimplate for semi- flush mounting to a standard 4 square backbox. or surface mounting to Wheelock's indoor BB backbox or outdoor WBB backbox. For bell strobe applications, retrofit plates Wheelock Series RSSP with Multi-Candela or Single Candela strobes shall be used. All 1 bell models shall be polarized for line supervision and shall have screw terminals for in-out field wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be textured enamel. Order Model Number Nominal Voltage VDC) • Strobe Candela Average Current (AMPS) I at listed VDC UL Max*Code f Options Mounting RSSP-24MCW-FR 9402 24 15/30,75/110 f .041/.063/.109/.140 .060/.092!.165/220 D.E.Z RSSP-241575W-FR 7793 24 15 (75 on-axis) I .060 .090 D.E2 1RSSP-121575W-FR 7798 12 155 (75 on-axis) .152 .255 D.E.Z * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Fig. I Bell Models Fig. 2 Retrofit Strobe AUDIBLE STROBE + + I Plate Models (RSSP) Vi __ FROM PRECEDING - NEXT FROM TO NEXT APpLIANCE OR FACP + APPLIANCE + _____________ ___________ PRECEDING APPLIANCE { APPLIANCE } OR RESISTOR OR ED R OR FACP (EOLR) FROM TO NEXT - - PRECEDING STROBE OR STROBE OR + FACP + EOLR Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL). National Electrical Code (NEC). Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to-, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). AWARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION ASSEMBLED IN THE USA 7 NATIONAL SALES OFFICE 3 YEAR WARRANTY 800-631-2148 Canada 800-397-5777 E-Mail: lnfo@wheeiockinc.com . http://www.wheelockico.com I .•1. 273 BRANCHPORT AVENUE • LONG BRANCH, NJ 07740 • TEL: Distributed By: 732-222-6880 • FAX: 732-222-2588 S1500 02/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM S USTNG ERVICE LISTING No. 7135-0785:113 Page 1 of 1 CATEGORY: Audible Devices LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Model MB series bells and Model MBS series bell/strobes. Models MB are suitable for outdoor use when used with Model WBB backbox. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire . Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager SIEMENS Fire Safety S intelligent InitED iating Devices Manua' Fire Alarm Boxes MSMOB and MS20B Intelligent Manua' Are Alarm Boxes for MXL, IXL, and XL3 Control Panels ENGINEER AND ARCHITECT SPECI FICATIONS Durable Design Shock and Vibration Resistant Pull Down Lever Remains Down Until Reset S Custom Microcomputer Chip Technology Dynamic Supervision Polarity Insensitive with Sure\iVireTM Technology Reset with Allen Key No Break Rods Necessary Two Wire Operation Surface or Semiflush Installation DPU or FPl-32 Programs and Verifies Device's Address and Tests Device's Functionality Electronic Address Programming is Easier and More Dependable Single and Double Action Models Available ®, Listed, CSFM, FM and NYMEA Approved Introduction Siemens Building Technologies, Fire Safety Division MSl-10B and 20B intelligent manual fire alarm boxes provide the markets' most advanced method of address programming and supervision, combined with sophisticated control panel communication. Each MSl manual fire alarm box incorporates a new custom microcomputer chip. The microcomputer chip technol- ogy, and its sophisticated bi-directional communication capabilities with the control panel, achieves the state of an "Intelligent Initiating Device." Description The MSl-10B and 20B are constructed of durable molded polycarbonate material which is matte finished in red with raised white lettering. The housing accom- modates a "pull-down" lever which, when operated, locks in position indicating the manual fire alarm box .has been activated. The pull down lever remains down and locked until the manual fire alarm box is reset. The manual fire alarm box is reset only by opening the hinged housing cover with an alien key and then closing and locking the cover. The MSI-10B and 20B manual fire alarm boxes operate with the MXL, JXLJlCON-1 and XL3 control panels. The manual fire alarm box's microcomputer chip has the capacity of storing, in memory, identification information as well as important operating status information. Fire Safety's innovative technology also allows all MSI Series Intelligent manual fire alarm boxes to be pro- grammed by using the Model DPU or FPl-32 Program- mer/Tester. The Programmer/Tester is a compact, portable, menu driven accessory which makes pro- gramming and testing a manual fire alarm box device faster, easier and more dependable than previous methods. The DPU or FPl-32 eliminates the need for the device's mechanical addressing mechanisms, such as program jumpers, dipswitches or rotary dials because the Programmer/Tester electronically sets the manual fire alarm box's address into its microcomputer chip, nonvolatile memory. Vibration, corrosion and CATALOG NUMBER 6187 Replaces Catalog No 6162 other conditions which deteriorate mechanical address- ing mechanisms are no longer a cause for concern. The MSl-108 and 20B are fitted with screw terminals for connection to an addressable circuit. They can be either surface or semiflush mounted. The MS( Series manual fire alarm boxes derive their power,communicate information and receive com- mands over a single pair of wires. The MS( Series is compatible on the same circuit with all IL and 0-60 Series ionization, photoelectric or thermal detectors, TRI Series interfaces or CZM Series addressable conventional zone modules. The MSl-10B and 20B intelligent manual fire alarm boxes are Underwriters Laboratories, Inc. listed. Mounting Data Ordering Information Model Description I Shipping Wt. Lb. Kg. MSI-1013 Addressable Manual Fire Alarm Box, Single Action 2 .90 MSI-20B Addressable Manual Fire Alarm Box, Double Action 2.5 1.13 SB-5R Surface Mounting Box 1.5 .68 L500-620490 Reset Tool Package (Contains 2 Tools) .5 .23 HOUSING HINGED TO BACKPLATE 1 3/ in HOUSING - oI BACKPLATE SURFACE MOUNTING ENCLOSURE 3½ in DEEP SWITCH BOX. (USER SUPPLIED) Siemens Building Technologies Fire Safety Fire Safety 8 Ferr.wood Road Florham Park, Ni 07932 Tel: (973) 593-2600 FAX (973) 533-6670 V\iebsire www,sot.s;emens.co.niifs Fire Safety 2 Kenview Boulevard 7/03 Brampton, Ontario 5M Canada LST 564 SFS-IG Tel: (905) 799-9937 Printed in Ij S A. FAX (9051 799-9858 July 2003 sucerseaeS fl'eei dated bc? CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM USTNG SERVICE LISTING No. 7300-0067:145 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932 Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652 DESIGN: Model FP/32 field programmer/tester. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name or Cerberus Pyrotronics, model number, electrical rating and UL label. APPROVAL: Listed as an accessory device for use with Model 1060 series smoke detectors (CSFM Listing No. 7271-0067:101, 7272-0067:121, and 7270-0067:108) and Model MSl series boxes (CSFM Listing No. 7150-0067:036). Rev. 10-26-2002 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. S Date Issued: JUNE 9, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Listing Expires June 30, 2007 4*0 SIEMENS Fire Safety Intelligent Fire Detector for MXL MXLQ, and MXLV Control Panels ENGINEER AND ARCHITECT SPECIFICATIONS Most Sophisticated "Detector Intelligence" available today Multi-Criteria fire detection for the price of a photoelectric detector FireprintTM Technology to discriminate between deceptive phenomena and an actual fire Easily programmed to match specific hazard profiles from the control panel Pre-Alarm reporting based on fire profile selected Remote sensitivity measurement capability System logic activation based on any of three inputs from detector (smoke, heat or neural network) Field cleanable chamber with replaceable chamber parts available Multi-color detector status LED Two-wire operation Compatible with Model DPU or FPl-32 field programmer/tester Supports EnviroLlNK software based automatic environmental compensation Backward compatible with older MXL systems (Rev. 2 and above) Optional fully programmable relay base, audible base, and duct housing Listed, ULC Listed, CSFM, FM, NYMEA &UL Approved Introduction The FP-fl Intelligent Fire Detector provides the life safety industry with the most highly evolved detection system available today. The FP-11 utilizes advanced detection technology that allows the detector to distinguish nonthreatening deceptive phenomena, such as cigarette smoke, from actual fire hazards, while optimizing detection for the area in which it is in- stalled. No other detection system available today offers a higher level of protection or nuisance alarm immunity. The FP-fl uses state-of-the-art microprocessor circuitry with error check, detector self-diagnostics and supervision programs. need for cumbersome, unreliable mechanical program- ming methods and reduces installation and service costs by electronically programming and testing the detector prior to installation. The FP-11 fire detector is compatible with the MXL family of control panels including the MXL, MXL-IQ, and MXLV. The FP-11 detector is Underwriters Laboratories and Underwriters Laboratories of Canada Listed. Description The FP-11 is a plug-in, two-wire, multi-sensor detector with both photoelectric and thermal inputs and is compatible with the MXL family of control panel systems. Each detector consists of a dust resistant, field cleanable photo chamber, a solid state CATALOG NUMBER ow 6175 The FE-il intelligent fire detector is compatible with .the Siemens Building Technologies, Fire Safety Divi- sion, Model DPU or FPI-32 field programmer/tester, which is a compact, portable, menu-driven accessory for electronically programming and testing detectors, easily and reliably. The DPU or FPI-32 eliminates the non-mechanical thermal sensor, microprocessor based electronics with a low-profile plastic cover and base. The FP-11 utilizes state-of-the-art ASIC and surface mount technology for maximum reliability. Every FP-11 fire detector is shipped with a protective dust cover. The FP-11 fire detector utilizes an infrared light emitting diode (IRLED), and light sensing photodiode. Under normal conditions, light transmitted by the LED is directed away from the photodiode and scattered through the smoke chamber in a controlled pattern. The smoke chamber is designed to manage light dissipation and extraneous reflections from dust particles or other non-smoke airborne contaminants in such a way as to maintain stable, consistent detector operation. When smoke enters the detector chamber, light emitted from the IRLED is scattered by the smoke particles and is received by the photodiode. The FP-11 also utilizes a modern, accurate, shock- resistant thermistor to sense temperature changes. The "on-board" FirePrint technology allows the detector to gather smoke and thermal data, and to analyze this information in the detector's "neural network' By comparing data received with the common characteristics of fires, or fire fingerprints, the FP-11 can compare these "Fire Prints" to those of deceptive phenomena that cause other detectors to alarm. The advanced FirePrint technology allows the FP-11 to accurately determine a true fire hazard from a nonthreatening deceptive phenomena WITHOUT needing to use alarm delaying verification and confir- mation techniques, which can increase the probability of losses due to fire. The FP-11 provides the highest level of detector intelligence available today with a detector/control panel link that allows the user to program the detector for the specific hazard profile Detectors are optimized by selecting one of the following applications: Office/Retail Lobby Computer Room Dormitory Healthcare Parking Garage Utility/Transformer Room Hostile Environment Precious Storage Air Duct Warehouse/Light Manufacturing The software does the rest; no guessing on detector sensitivities or alarm verification; the control panel programs the FP-11 detector for the protected area without hassle and without confirmation delays. Once optimized for the hazards in the protected area, the FP-11 provides the best detection you can buy. evaluating this information with sophisticated mathematical formulas, or algorithms, comparing this input to characteristics of both threatening fires and deceptive phenomena that would 'fool" any ordinary detector. This technology was developed over years of research and reviewing the results of over 20 years of fire test data in one of the world's most advanced fire research centers. The results of this research are the mathematical models that form the algorithms used in FirePrint. No other fire detector has this level of intelligence or this amount of research and develop- ment supporting it's design. The microprocessor's software can identify and disregard false input caused by radio frequency (RFI) and electromagnetic (EMI) interference, and validates all trouble conditions before annunciating or reporting to the control panel. The FP-11 detector's microproces- sor uses an integral EEPROM to store the detector's address and other critical operating parameters which include the assigned program values for alarm and trouble thresholds. Communications within the detector itself and between the FP-11 and the control panel, or with the FPI-32 field programmer/tester, are supervised and safeguarded against disruption by reliable, microprocessor based error checking routines. Additionally, the microprocessor supervises all EEPROM memory locations and provides a high degree of EEPROM failure fault tolerance. In MXL(V) applications, the FP-11 determines its operating status to be normal, in alarm, or in trouble depending on the difference between the alarm threshold values stored in the detector's memory and the detector's latest analog measurement. The detector then communicates changes in its status to the control panel. In addition, the MXL(V) control panel will sample the value of the FP-11's analog signal over a period of time in order to determine if those values indicate exces- sive buildup in the photo chamber; if so, the MXL(V) will indicate that the particular detector requires maintenance. The FP-11 is listed as a self-testing device. The FP-11's visible light emitting diode (LED) flashes green every 4 seconds to indicate it is communicating with the control panel and that it has passed its internal self- test. Should the detector sense a fault or failure within its systems, the LED will flash amber and the detector will transmit that information to the control panel. A quick visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the MXL panel indicating the status and settings assigned to each individual detector. When the FP-11 moves to the alarm mode, it will flash amber and transmit that information to the control panel. When the MXL(V) confirms the detectors condition, the panel will instruct the FP-11 to flash red and to continue flashing until the system is reset at the control panel. At that same time, any user defined • Should the operator or installer forget to program the detector, the FP-11 will revert to a default setting that allows it to operate as a standard photoelectric or photothermal detector. The FP-11's FirePrint technology monitors input from both the photo chamber and the thermal sensor, All FP-11 detectors are approved for operation withi n the UL specified temperature range of 32 to 100 degrees F (0 to 38 degrees Cl Application Data Installation of the FP-11 series of fire detectors requires a two-wire circuit of 18 AVVG (minimum) thermoplastic fixture wire enclosed in conduit, or 18 AWG limited energy, shielded cable without conduit, if permitted by local codes. Field wiring should conform to local and National Electric Codes and the control panel wiring specifications. "T-tapping" is permitted only for Style 4 (Class B) wiring. FP-11 fire detectors can be applied within the maxi- mum 30 foot center spacing (900 sq. ft. areas) as referenced in NFPA 72. This applications guideline is based on ideal conditions, specifically, smooth ceiling surfaces, minimal air movement, and no physical obstructions between potential fire sources and the detector. Do not mount detectors in close proximity to ventilation or heating and air conditioning outlets. Exposed joints or beamed ceilings may also affect safe spacing limitations for detectors. Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Siemens Building Technologies, Fire Safety Division authorized sales outlet whenever you need assistance applying FirePrint in unusual applications. Be sure to follow NFPA guidelines, UL/ULC approved installation instructions, which are included with every detector, and local codes as for all fire protection equipment. Dimensions system alarm functions programmed into the system are activated. Each FP-11 detector can operate one remote alarm indicator, one auxiliary relay, or one audible base. Detector sensitivity, calibration, and identification are dynamically supervised by the control panel. Detector sensitivity and pre-alarm levels are a function of the application chosen at the control panel and are controlled by the panel. If an alternate, non-FirePrint mode is selected, then the sensitivity can be changed from the control panel. The DPU or FPl-32 Program/Test accessory is used to program and verify the detector's address. The technician selects the accessory's program mode to enter the desired address. The DPU or FPI-32 auto- matically sets and verifies the address and tests the detector. It also allows the user to change the device ID from that of an FP-11 to an older detector ID such as an lLP-1, ILPT-1, lLP-2, ID-60P or ID-60PT to allow for easy replacement of older detectors without the need of reprogramming the control panel. The FPl-32 operates on AC power or rechargeable batteries, providing flexibility and convenience in programming and testing equipment almost anywhere. When in the test mode, the DPU or FPI-32 will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. The FP-11 fire detector may be installed on the same initiating circuit with IL or ID series detectors (Photo- electric, thermal, or ionization), MSI series manual stations, TRI series interfaces, ICP output control devices, or CZM series of addressable, conventional zone modules. All FP-11 detectors can be cleaned in the field, when required, by simply removing the detector cover and unsnapping the photo chamber. There is also the option of cleaning the interior of the detector with a clean, soft cloth or brush, or replacing the labyrinth and bug screen included in the detector maintenance kit, model DMK-11. The FP-11 uses the low profile surface mounting base, model DB-11. This base mounts on a 4-inch octagon, square, or a single gang electrical box. The base utilizes screw clamp contacts for electrical connections and self-wiping contacts for increased reliability. The base can be used with the optional LK-1 1 detector locking kit which contains 50 detector locks and an installation tool, to prevent unauthorized removal of the detector head. The DB-11 base has integral decora- tive plugs to cover the outer mounting screw holes. The FP-11 is electrically compatible with existing MXL detector accessories including relays, remote lamps, • duct housings, and audible bases. With duct housings, a base adapter and new detector housing cover are required (order AD-11UK upgrade kit). To use existing DB-3S base or audible base. the FP-11 requires a DB- ADPT base adapter. S Technical Specifications Current Requirements: Normal 750 pa Alarm 750 pa Operating Temperature: +32°F (0°C) to 100°F (38°C) per UL 268/268A Humidity: 0-93% Relative Humidity Non-Condensing Orderi ng Information I Model Description Part Number FP-11 Addressable FirePrint Fire Detector 500-095112 08-11 Detector Mounting Base for Series 11 500-094151 OB-IlE Detector Base (Small) Air Duct Housing for Series 11 - 500-094157E- AD-11P 500-095656 AD-I1XPR Air Duct Housing w/Relay for Series 11 Intelligent Detector 500-096062 ADBX-11 Audible Base 500-096181 DB-X11RS Relay Base for Series 11 Intelligent Detectors 500-096125 RLI-1 Remote (red) alarm indicator- 4 octagon box mount 500-390673 RLI-2 Remote (red) alarm indicator- single gang box mount 500-390674 LK-11 Base Locking Kit for Series 11 detectors 500-695350 DMK-11 Series 11 Maint Kit (replacement labyrinth and bug bug screen) I 500-695338 AD-IlUK Air Duct Housing Cover/Adapter Kit 500-695967 08-ADPT Base Adapter to DB-3S Base 500-094187 In Canada Order: FP-11C Addressable FirePrint Fire Detector (ULC( 500-095112C DB-11C Detector Mounting Base for Series 11 (ULC) 500-095687 AD-11PC Air Duct Housing (ULC) 500-095984 DB-X11 RSC Relay Base for Series 11 Intelligent Detectors (ULC( 500-096125C ADBX-IIC Audible Base for Series 11 Intelligent Detector (ULC) 500-09618W Siemens Building Technologies Are Safety Fire Safety B Fernwood Road Florham Park, NJ 07932 Tel 9731 593-2600 FAX. (973) 593-6670 Website www. abtsiemens :om/f is 6/03 1GM SF 5-10 Pr;riied in U S.A Fire Safety 2 Kanview Boulevard Brampton, Ontario Canada LST 5E4 Tel (905) 799-9937 FAX: (905) 799-9858 June 2003 Suoerscdes sheet aaiednt2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM USfiNG SERVICE LISTING No. 7272-0067:203 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Siemens Building Technologies Inc., Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932 Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652 DESIGN: Models FP-1 1, HFP-1 1, and *HFp0..1 1 analog and FP0-1 1 photoelectric type smoke detectors. Models FP-1, and HFP-1 1 also have a supplemental 1350F heat sensor. Model DGH-1 1 detector guard housing suitable for use with Models HFP-1 1, *HFPo..1 1 and FP-11 smoke detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. These detectors are intended for installation on a vertical wall surface or the ceiling. They are also acceptable for duct application with an air velocity of 0-4000 ft/mm. when used with Models DB-1 1, DB-HR or DB-X1 1 RS bases. MARKING: Listee's name, model number, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with listee's separately listed base Model DB-1 1, DB-HR or DB-X1 IRS (CSFM Listing No. 7300-0067:134) and separately listed compatible fire alarm control units. Model DGH-1 1 detector guard housing is listed for use only with FP-1 1 and HFP-1 1. Refer to listee's Installation Instruction Manual for details. *Rev. 09-27-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 9,, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-0067:134 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories USTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932 Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652 DESIGN: Models D134T, DB4TS, DB4F, DB4TF, DB4FS, DB3S, ADB3, ADBX3, DB-HR, DBX3RS, DB-1 1 DB-X1 iRS, ADBI60, ADB-1 1, ADBH-i 1, ADBX-1 1 and 8837 detector bases and Model DB-ADPT detector/base adapter. Suitable for use with Models RR2 or RR3 auxiliary relays. Model DB-i 1 is suitable for use only with Model RR-1 1 or RR-1 1 F auxiliary relay. Models DB-1 1 base, ADBH-i 1 audible base, and DB-HR relay base are intended to be used with Models HFP-1 1 and HFPT-1 1 Intelligent Series smoke and heat detectors (CSFM Listing No. 7272-0067:223 and 7270-0067:224). Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model DB-1 1, ADBH-i 1 and DB-HR may be installed on the ceiling or on the wall. MARKING: Listees name or Cerberus Pyrotronics, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible smoke detector heads and fire alarm control units. Rev. 10-28-2002 JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager SIEMENS Fire Safety FPT-11 IntelligentThermal Detector for MXL, MXL4Q and MXLV Control Panes ENGI NEER AND ARCHITECT SPECI FICATIONS FPT-11 Microprocessor Based Design Rate of Rise and Fixed Temperature Innovative Technology Provides High Speed, Fault Tolerant System/Detector Communications -............ a Multi-Color Detector Status LED Optional Fully Programmable Relay Base and Audible Base - Two-Wire Operation ,. Backward Compatible with Older MXL Systems F (Rev 2 and Above) Compatible with DPU or FPI-32 Field Programmer/Tester • @Listed, ULC Listed CSFM, FM, NYMEA Approved Introduction The FPT-1 1 intelligent thermal detector provides an advanced method of detection, address programming and supervision, combined with sophisticated control panel communication .The FPT-1 1 detector uses a state-of-the- art thermistor providing 135°F fixed temperature and 15° per minute rate-of-rise alarm points. The user also has the option of disabling the rate-of-rise feature leaving just a fixed temperature sensor. The FPT-1 1 intelligent thermal detector is compatible with the DPU and FPI-32 field program mer/testers. These testers are compact, portable, menu-driven accessories which make programming and testing detectors faster, easier and more reliable than other methods. They eliminate the need for cumbersome, unreliable mechani- cal programming methods and reduce installation and service costs by electronically programming addresses and functionally testing the FPT-11 's performance before the detector is installed. The FPT-1 1 thermal detector operates with the MXL family of control panels including MXL, MXL-10 and MXLV. The FPT-1 1 intelligent thermal detector is Underwriters Laboratory listed and Underwriters Laboratory of Canada listed. Description The FPT-11 is a plug-in, two-wire thermal detector, compatible with the MXL family of control panels. Each FPT-11 has microcomputer chip technology and highly stable solid state electronic circuitry. The FPT-11 utilizes a modern, accurate, shock-resistant thermistor to sense temperature changes. This elec- tronic sensing method virtually eliminates thermal lag associated with mechanical temperature sensing devices and provides almost instantaneous tempera- ture information to the control panel. The FPT-11, in its default mode, is a combination 135°F fixed tempera- ture and 150 per minute, rate-of-rise detector. It can be programmed from the control panel as a fixed temperature detector without rate-of-rise, at the users option. CATALOG NUMBER 6176 The FPT-11 detector's microprocessor uses an integral EEPROM to store the detector's address. Communi- cations within the detector itself and between the FFT- ii and the control panel, or with the FPI-32 field programmer/tester, are supervised and safeguarded against disruption by reliable, microprocessor based error checking routines. Additionally, the microproces- sor supervises all EEPROM memory locations and provides a high degree of EEPROM failure fault tolerance. The FPT-11 is listed as a self-testing device. The FFT-1I's visible light emitting diode (LED) flashes green every 4 seconds to indicate it is communicating with the control panel and that it has passed its internal self-test. Should the detector sense a fault or failure within its systems, the LED will flash amber and the detector will transmit that information to the control panel. A quick visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the MXL panel indicating the status and settings assigned to each individual detector. When the FPT-1 1 moves to the alarm mode, it will flash amber and transmit that information to the control panel. When the MXL(V) confirms the detectors condition, the panel will instruct the FPT-1 1 to flash red and to continue flashing until the system is reset at the control panel. At that same time, any user defined system alarm functions programmed into the system are activated. Each FPT-11 detector can operate one remote alarm indicator, one auxiliary relay, crone audible base; but only one acces- sory per detector. A DPU or FPI-32 programmer/tester is used to program and verify the detector's address. The user selects the Program Mode to enter the desired address. The pro- grammer/tester then automatically sets and verifies the address as well as tests the detector. The programmer/ tester has rechargeable batteries, so a detector's address can be programmed by the user from the most conve- nient location. The user can also separately test the detector for functionality. When the user selects theTest Mode, a series of tests are automatically conducted and the user is informed whether the detector has passed or failed. The FPT-1 1 detector is compatible on the same MXL initiating circuit with other IL Series, FP Series or D-60 Series addressable ionization, photoelectric, or thermal detectors, MSI addressable manual stations, TRI Series addressable interfaces, or CZM Series addressable conventional zone modules. Each FPT-1 1 thermal detector is capable of operating one "X" or "1" Series remote alarm indicator or auxiliary relay or audible base.The FPT-11 detectors use a surface mounting base, Model DB-11, which mounts on a 4-inch S octagonal, square or single gang electrical box. Relay base Model DB-X11 RS mounts to a 4-inch square deep electrical box. Audible base Model ADBX-11 also mounts to a 4-inch square deep electrical box. The DB-1 1, and the DB-X1 IRS and ADBX-1 1 use screw- clamp terminals for all electrical connections and self- wiping contacts for reliability. The bases also contain a provision for an optional concealed locking mechanism to prevent unauthorized removal of the detector head, Model LK-11. Application Data The MXL uses ALD loop circuits with each circuit capable of supporting up to sixty FPT-11 intelligent detectors. The detector, or group of detectors, require a two-wire Circuit of minimum 18 AVVG thermoplastic fixture wire enclosed in conduit, or minimum 18 AWG limited energy, shielded cable without conduit if permitted by local building codes. Wiring should conform to local and National Electrical Codes, and to the control panel's wiring specifications. T-tapping is permitted only for Style 4 (Class B) wiring. Locate the FPT-11 on the ceiling, at least 4 inches from the side walls. For an ideal, smooth ceiling condition, place the detectors at a maximum center spacing of 50 feet (2500 square feet), 25 feet from side walls or room partitions. Actual job conditions and sound engineering judge- ment must determine detector spacing. Consider environmental factors including ambient temperature fluctuation, and the nature of the fire hazard. Room or area configuration and ceiling type (sloped or flat, smooth or beamed) also dictates placement. Should questions arise regarding detector placement, follow the drawings provided and/or approved by Siemens Building Technologies, Fire Safety Division or by its authorized distributors. This is extremely impor- tant! The detector placements shown on these drawings were chosen after a careful evaluation of the area being protected. Fire Safety's extensive experience in design of the system assures the best detector placement by following these drawings. Technical Specifications Current Requirements: Normal 750 pa Alarm 750 pa Operating Temperatures: +32°F (0°C) to 100° F (38°C) Humidity: 0-93% Relative Humidity Non-condensating S Ordering Information Model J Description Part No. FPT-11 Addressable Thermal Fire Detector 500-095918 DB- 11 Detector Mounting Base for Series 11 500-094151 08-11 E Small 4.5 inch Diameter Detector Base 500-094151 E DB-XII RS Relay Base for Series 11 Intelligent Detectors 500-095125 ADBX-11 Audible Base for Series 11 Intelligent Detector 500-096181 9L;-I Remote (red) alarm indicator-octagon box mount 500-390673 RLi-2 Remote (red) alarm indicator-single gang box mount 500-695350 LK-11 Base Locking Kit for Series 11 500-695350 DB-ADPT Base Adapter to DB-3S Base 500-094187 In Canada Order: FPT-11C Addressable Thermal Fire Detector )ULC) 500-0959180 DB-11C Detector Mounting Base for Series 11(ULC) 500-095687 DB-X11RSC Relay Base for Series 11 Intelligent Detectors )ULC) 500-096125C ADBX-11 C Audible Base for Series 11 Intelligent Detector )ULC) I 500-096181C Dimensions S 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S UST1NpftG SERVICE LISTING No. 7270-0067:202 Page 1 of 1 CATEGORY: Heat Detector LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932 Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652 DESIGN: Model FPT-1 1 electronic fixed temperature heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 135°F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name or Cerberus Pyrotronics, model number, temperature rating and UL label. APPROVAL: Listed as heat detector for use with separately listed compatible fire alarm control units. Intended for use with listee's Model DB-1 1 base (CSFM Listing No. 7300-0067:134). Rev. 10-26-2002 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. • Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM USTNG SERVCE LISTING No. 7300-0067:134 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932 Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652 DESIGN: Models DB4T, DB4TS, D134F, DB4TF, DB4FS, DB3S, ADB3, ADBX3, DB-HR, DBX3RS, DB-1 1 DB-X1 1 RS, ADBI60, ADB-1 1 ADBH-1 1, ADBX-1 1 and 8837 detector bases and Model DB-ADPT detector/base adapter. Suitable for use with Models RR2 or RR3 auxiliary relays. Model DB-1 1 is suitable for use only with Model RR-1 1 or RR-1 1 F auxiliary relay. Models D13-1 1 base, ADBH-1 1 audible base, and DB-HR relay base are intended to be used with Models HFP-1 1 and HFPT-1 1 Intelligent Series smoke and heat detectors (CSFM Listing No. 7272-0067:223 and 7270-0067:224). Refer to I istee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model DB-1 1, ADBH-1 1 and DB-HR may be installed on the ceiling or on the wall. MARKING: Listees name or Cerberus Pyrotronics, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible smoke detector heads and fire alarm control units. Rev. 10-28-2002 JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager SIEMENS Fire Safet Intelligent Initiating Devices Interface Modules for MXL Fire Detection Panels TRS,TR=D,TRFR ENGINEER AND ARCHITECT SPECIFICATIONS Interfaces and Supervises Normally Open Contacts Integral SPDT Relay (up to 4 amps) on TRI-R Model Dual Input on TRI-0 Model Multi-color L.E.D. indicates status (green, amber, red) Easy front access to programming port and wiring terminals Mounts in 4 inch square 21/4 deep box, or double gang box Dynamic Supervision Comes with 5x5 inch faceplate Two wire operation Model DPU or FPl-32 Programs and Verifies Device's Address and Tests Device's functionality Electronic Address Programming is Easy and Dependable t1L UL Listed, ULC Listed CFSM, FM, NYMEA Approved Introduction The TRI Series Intelligent interface modules are designed to provide the means of interfacing direct shorting devices to the MXL system's ALD loop circuit. The TRI Series Intelligent interface modules provide the market's most advanced method of address programming and supervision, combined with sophis- ticated control panel communication. Each TRI Series interface module incorporates a microcomputer chip. The TRI Series microcomputer chip technology and its sophisticated bi-directional communication capabilities with the control panel, achieve the state of an "Intelli- gent Device." Description The TRI Series Intelligent interface modules are avail- able in three models. The TRI-S and TRI-R are designed to monitor a normally open dry contact. The interface module reports the contact's status to the control panel. The TRI-S model can only monitor and report the status of the contact, while the TRl-R incorporates an addressable Form C relay. The TRI-R relay and contact device input are controlled at the same address. For the MXL system, the relay and input contact can be controlled as a separate function. The relay is typically used where control or shunting of external equipment is required. The TRI-D is a dual input module and is designed to supervise and monitor two sets of dry contacts. This interface module requires two address settings. The TRI-D is ideal for monitoring a waterflow switch and its respective valve tamper switch. The TRI has a multi-color Light Emitting Diode that flashes green when operating normally, amber if unit CATALOG NUMBER 6179 Mounting Data Addressable interface Model TRI-S, TRI-D, TRI-R mounts directly into a 4 inch square 21/4 deep box or a double gang box (user supplied). A 5 inch square off-white faceolate is included with each TRI. MOUNTING SLOTS FOR 4 INCH S\jV(TCH BOX TR I-S/-D/-R MODULE DUNTING )LES FOR VITCH PLATE MOUNTING SLOTS FOR DOUBLEGANG SWITCHBOX Figure A Mounting the TRI-S/-R/-D is in trouble condition, and red to indicate a change of state. The TRI-D flashes twice, once for each address the TRI-R red L.E.D. indicates a change of state in the relay. V The device's microcomputer chip has the capacity of storing, in memory, identification information as well as important operating status information. Siemens Building Technologies, Fire Safety Division innovative technology allows all TRI Series intelligent interface modules to be programmed by usiiig the model DPU or FPl-32 Programmer/Tester. The Pro- grammer/Tester is a compact, portable, menu driven accessory that makes programming and testing an interface device faster, easier and more dependable than previous methods. The DPU or FPl-32 eliminates the need for mechanical addressing mechanisms, such as program jumpers, DIP switches or rotary dials, because the Programmer! Tester electronically sets the TRI interface's address into the interface's microcomputer chip nonvolatile memory. Vibration, corrosion and other conditions that deteriorate mechanical addressing mechanisms are no longer a cause for concern. The TRI Series is fitted with screw terminals for connection to an addressable circuit. The TRI Series is fully compatible on the same MXL .circuit with all intelligent FP IL and ID-60 Series detectors, MSl Series addressable manual stations or any other addressable intelligent modules, such as the CZM or ICR All TRI Series intelligent interface modules are UL listed. Environmental operating conditions for all TRI Series modules are 32°F (°C) to 120°F (49°C) with a relative humidity of not greater than 93% non-condensating. Ordering Information Model Description Shipping Wt. Lb. Kg. TRI-S Single Input 7 oz. 2 TRI-R Single Input w/Relay 7 oz. 2 TRI-D I Dual Input 7 oz. 2 Electrical Ratings Current Draw (Active or Standby): 1.5mA TRI-R Relay Ratings Resistive: 4A, 125 VAC 4A, 30 VDC Inductive: 3.5A, 120 VAC (0.6FF) 3.0A, 30 VDC (0.6FF.) 2.OA, 120 VAC (0.4FF) 2.OA, 120 VAC (0.35FF) 2.OA, 30 VDC (0.35FF) Siemens Building Technologies Fire Safety Fire Safety 8 Fernwood Road Fiorham Park, NJ 07932 Tel: (973) 593-2600 FAX. (973) 593-6670 vVebsite: www.sbt siemens.corn/fis 7/03 SM SFS-iG Printed ri U S.A. Fire Safety 2 Keriview Boulevard Brampton. Ontario canada LS' 5E4 Tel: (905) 799-9937 FAX. 19051 799-9858 July 2003 Sucersedes Sheet isted /03 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 0 USTNG SERVICE LISTING No. 7300-0067:146 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932 Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652 DESIGN: Models TRI-2, TRI-2D, TRl-2R, TRI-60, TRI-60D, TRl-60R, TRI-86, TRl-136D, TRI-B6R, TRI-136M, TRI-D, TRI-R and TRl-S addressable modules and TRI-CB supervisory module. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name or Cerberus Pyrotronics, model number and UL label. APPROVAL: Listed as control unit accessories for use with Model XI-3 (CSFM Listing No. 7165-0067:104 and 7170-0067:151), Model MXL (CSFM Listing No. 7165-0067:144 and 7170-0067:154) or . IXL (CSFM Listing No. 7165-0067:138 and 7170-0067:153) fire alarm control units. The TRI-CB module is designed for use with the TRI-2, TRl-2D and TRI-2R modules when interfaced with the INX module. Rev. 10-26-2002 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Dare Issued: JUNE 9, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Fire Sfet Intelligent Device Interface Module ENGINEER AND ARCHITECT SPECIFICATIONS Intelligent Interface Modules For MXL and IXL Control Panels Interfaces and Supervises Normally Open (Fire Detection) or Normally Closed Contacts (Security Detection) Compact Size Allows Mounting in Single Gang Box Behind Equipment S Operates with MXL ALD Loop, MXL XLD Loop or IXL ICon Loop Microcomputer Chip Technology Innovative Technology Supports Comprehensive System and Interface Communication Dynamic Supervision Two Wire Operation SensorLiNk, model FPI-32 Programs and Verifies Device's Address and Tests Device's Functionality Electronic Address Programming is Easier and More Dependable (V L Listed, ULC Listed, CSFM and NYMEA Approved or~ 7 - -.-- - ji Mika- Introduction TheTRI-B6M Intelligent interface module is designed to provide the means of interfacing direct shorting devices to the MXL system's ALD loop circuit, MXL XLD loop or the lXL system's lCon loop circuit. TheTRI-B6M Intelligent interface module provides the market's most advanced method of address program- ming and supervision, combined with sophisticated control panel communication. Each TRl-B6M interface module incorporates microcomputer chip technology and its sophisticated bi-directional communication capabilities with the control panel. Description The TRl-66M is designed to monitor a normally open or closed dry contact and reports the contact's status to the control panel. The devices microcomputer chip has the capacity of storing, in memory, identification information as well as important operating status information. Siemens Building Technologies, Fire Safety Division innovative technology allows all TRl-B6M intelligent interface modules to be programmed by using the SensorLiNK model FPl-32 Programmer/Tester. The FPI-32 Programmer/Tester is a compact, portable, menu driven accessory that makes programming and testing an interface device faster, easier and more dependable than previous methods. The FPI-32 eliminates the need for mechanical addressing mechanisms, such as program jumpers, DIP switches or rotary dials, because it electroni- cally sets thelRl-86M interface's address into the interface's microcomputer chip non-volatile memory. Vibration, corrosion and other conditions that deteriorate mechanical addressing mechanisms are no longer a cause for concern. This TRl-B6M is connected to the programmer/ tester with the programming cable provided with the tester. This cable utilizes two (2) alligator clip connec- tors, to attach to the TRl-B6M. (P/N 110-694927) The TRI-86 Series has five leads, one for grounding, which are wired to the system with user supplied wire nuts. CATALOG NUMBER 6170 Ordering Informati on Model Description Shipping Wt. oz. Kg. iRI86M Single Input 3.5 1 TRI-86M-C ULC Model for Canada 35 Typical Wiring (Refer to Figures 1, 2, 3 or 4) Refer to the appropriate wiring diagram below and wire the addressable inter- face module accordingly. Note: Recommended wire size: 18 AWG minimum 14 AWG maximum The TRI-136M is fully compatible on the same MXL circuit with all intelligent IL and 0-60 Series detectors, S MSI Series addressable manual stations or any other addressable intelligent modules, such as the CZM or ICP The TRl-136M is also fully compatible on the IXL (iCon) circuit with all intelligent IL and ID-60 detectors and MSI manual stations. AIITRI-B6M intelligent interface modules are UL and ULC listed. Environmental operating conditions for allTRl-B6M mod- ules are 32°F (°C) to 120°F (49°C) with a relative humidity of not greater than 93% non-condensating. Engineer & Architect Specifications The addressable interface module shall incorporate a custom microprocessor based integrated circuit that shall provide communication with its compatible control panel. The addressable interface module shall be a Fire Safety TRI-136M that shall be compatible with a IXL or MXL control panel. TheTRl-1361VI intelligent interface modules shall provide the means of interfacing direct shorting devices to the control panel's addressable circuits. The interface •module' shall report the contact's status to the control panel. The TRI Series devices shall be capable of and listed for interfacing normally closed security switches to the MXL (per UL 1076). The addressable interface module shalt be UL and ULC listed. The addressable interface module shall be dynamically supervised and uniquely identifiable by the control panel. The addressable interface module's address shall be programmed with the use of a portable programming accessory. The programming accessory shall be a Fire Safety FPl-32 Programmer/Tester. The portable program- mer shall be menu driven. Once the desired address is entered the programmer shall set and verify the address. The programming accessory shall also be capable of testing the interface's functionality. The addressable interface module's address shall be set by electronic means only. No mechanical means such as programming pins, DIP switches or rotary dials shall be required. TheTRI-136M shall be compatible on the same MXL circuit with other intelligent IL and ID-60 Series detectors,TRI Series addressable interfaces, MSI Series addressable .M anual stations or any other XL addressable intelligent odule. TheTRl-86M shall be compatible on the same IXL (ICon) circuit as other intelligent IL and ID-60 Series detectors, MSI Series manual stations andTRl Series interfaces. S I nstalling A Security Point WARNING: These circuits intended for 24 hour alarm monitoring only. UL 1076 requires a TSW-1 tamper switch as well as a TSP-40 printer. A COMMUNICATION FAILURE with a TRI device configured for SECURITY results in a SECU- RITY ALARM as well as a communication trouble. When installing a TRI device in the CSG-M, be sure to set the device usage to security. When setting the device address using the FPl-32, select the normally closed alarm causing input. Connect only one switch per TRI input. Reminder: Proper installation procedure for TRI Devices As part of the normal installation practice each TRI device must be functionally tested. This includes testing the supervision through the end of the line resistor. The following steps must be followed for each TRI device installed: Open the end of line resistor. Check that the system annunciates the programmed trouble message. 3, Return the resistor to its proper connection. Change the state of the switch to confirm that the systems programmed response is executed. Return the switch to its normal state. Mounting Diagram NOTE: DO NOT USE REAR CONDUIT ENTRY - - - - - - - - - L TRI-B6M SINGLE GANG I SWITCHPLATE (BLANK) (USER SUPPLIED) L. SINGLE GANG SWITCHBOX (USER SUPPLIED) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM USTNG SERVICE LISTING No. 7300-0067:146 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932 Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652 DESIGN: Models TRI-2, TRI-2D, TRl-2R, TRI-60, TRI-60D, TRI-60R, TRI-B6, TRI-B6D, TRI-B6R, TRI-136M, TRI-D, TRI-R and TRl-S addressable modules and TRI-CB supervisory module. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name or Cerberus Pyrotronics, model number and UL label. [1 APPROVAL: Listed as control unit accessories for use with Model XL3 (CSFM Listing No. 7165-0067:104 and 7170-0067:151), Model MXL(CSFM Listing No. 7165-0067:144 and 7170-0067:154) or lXL (CSFM Listing No. 7165-0067:138 and 7170-0067:153) fire alarm control units. The TRI- CB module is designed for use with the TRI-2, TRI-21D and TRI-2R modules when interfaced with the INX module. *Rev. 10-26-2002 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Electron agne ic...Fire Oocr Holders III Description: DR series fire door holders are constructed of the finest materials and workmanship available. The door holder is made of durable die-cast metal finished in high lustre double chrome or brass plating. Other features include standard dual voltage ac or dc inputs of 12 & 24V, 24 & 120V and 24 & 220V models. While reducing stocking requirement s, model 24120 draws a mere .020 m. @ 24VDC lowering overall job costs. (in large installations the cost savings can be substantial). Other features: single or double coil floor mounting, surface mounting and direct wall mounting. No brackets are required. The DH series door holder offers a new installation technique using a adhesive template assuring alignment without secondary adjustments. Accassories include extension and misalignment rods (various lengths) enabling parallelism between door and wail at distances greater than 12 inches and misalignment over 4 inches. Aiding in installation is the aircraft quality DH drijl fixture that reduces installation time and provides a near perfect alignment of catch-plate and armature, again - lowering overall installation costs. Basic units offer superior holding force and low residual magnetism. Models 1224 and 24120 can operate at higher listed voltages producing holding forces in excess of 1001bs. (45.3kg.) for special applications. Extension Rod Appcations Dual Voltage (rear view shown) r (. DNEI DUETS CUED 75.2 /CLTAGE IC IL H ..-.. HIGH I IOL.UGE . ) Standard Features: Very low current draw. Dual voltage inputs. Terminal block connections. High holding force. Low residual magnetism. Double chrome plating. o Mounting hardware & instructions. Optional Features: Double brass plating. Extension and misalignment rods. Surface mount back box. Time saving drill fixture (far mounting catch Plate). MADE IN THE U.S.A. MODEL VOLTAGE 12V L — 124 24V 24V24120 L 120V 24V 24220 220V DC/mA I AC/mA 1 Terminals, LB. KG. .040 .038 C & L 30 13.6 .040 .036 C & H 30 j 13.6 .020 .019 C & L 40 .18.1 - .020 C & H 35 15.8 .020 .019 C & L 40 18.1 - .015 C & H 25 11.3 NOTE: Holding forces listed in above table correspond with shaded values, non shaded values are slightly less. MODEL J VOLTAGE DC/mA AC/mA 1 Terminals LB. KG. 1224 24V I .085 .081 I C&L 75 34.0 24120 120V - .100 I C & L 110 49.81 HIGH HOLDING FORCE/SPECIAL APPLICATIONS: To obtain performance values in table above apply high listed voltage to low voltage terminals (C & L). NOTE: This configuration can only be applied to models 1224 & 24120. OHE1.5 01452 - 31452 014544 55. --------------¶..—.— 76.:fl.n.. - •013•fl,fl. _J Installation Tools: DHDF (drill fixture) Extension Wrenches Z--' 44nflm. 70 DHCPC Catch plate assembly chrome. DHCPB Catch plate assembly brass. DHDC Catch disc only chrome. DHDB Catch disc only brass. DHBBC Surface back box chrome DHBBB Surface back box brass. DHW Extension wrenches. DHDF Drilling fixture. 14! 14 PERFORMANCE DATA: ©N Q 14N F GTC Door Holder Legend: OH = Door Holder F = Flush Mount S = Surface Mount G = Ground Mount C = Chrome Plating B = Brass Plating 1 = Single Coil 2 = Double Coil NOTE: #2 indicates double coil ground mount model. Extensions: xtension rods • ACCESSORIES Surface Mounting: OHEB (back box) Example: DH (24120) (5) Door holder Model/Voltage 1224, 24120, 24220 Mount SMe Surface, Flush, Ground Finish Chrome, Brass Coils 1.2 ACCESSORIES: Extensions: DHE1C 1 inch extension chrome. DHE1B 1 inch extension brass. DHE1C 1-1/2 inch extension chrome. DHE15B 1-1/2 inch extension brass. DHE2C 2 inch extension chrome. DHE2B 2 inch extension brass: DHE3C 3 inch extension chrome. DHE38 3 inch extension brass. DHEAC 4 inch adjustable extension chrome. DHEAB 4 inch adjustable extension brass. Hardware: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM USTNG SERVICE LISTING No. 3550-1039:100 Page 1 of 1 CATEGORY: Door Closer/Holders/Releasing Devices LISTEE: RSG, 3300 E. 59th St., Long Beach CA 90805 Contact: Louis Finkle *(562) 630-4684 FAX (562) 529-5100 DESIGN: Models DH-12,-24,-120,-1224,-24120, and -24220 doorcloser/holders. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 12V, 24V, 120V, and 220V INSTALLATION: In accordance with listees printed installation instructions and applicable codes and ordinances. The system is intended to be mounted in a horizontal position only. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as door closer/holders for use with separately listed compatible detectors and fire alarm control units. Rev. 06-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager S 5128/5129 Save IPZ1 Fire Communicator (fltj Cost-effective solution to most fire communicator applications. The 5128 and 5129 (5128/29) are four channel slave fire communicators designed to monitor UL listed local fire alarm systems. The 5128/29 are a cost-effective answer to most fire communicator applications and are easy to install and service. Silent Knight knows digital communication. With hundreds of thousands of our communicators worldwide, it shows. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description The 5128/29 fire communicators provide four fully supervised channel inputs to monitor UL listed fire alarm systems. The 5128 comes in a vinyl and acrylic enclosure for mounting in the fire alarm control panel (FACP) cabinet. The 5128 can report AC power trouble using a dry contact active high voltage input. The 5129 comes in a metal cabinet for surface mounting near the FACP. The 5129 can monitor AC voltage directly. Features UL listed as a slave fire communicator for connection to UL listed 24 VDC local FACPs Four fully supervised input channels programmable as voltage input active high or low or as a contact closure input Dual phone line interface and line fault monitors Automatic 24 hour test Reports in most major communication formats Compact size of 5128 allows mounting in most local FACPs Easy to install and service Program the 5128 to report FACP AC trouble immediately or delay reporting from 6 to 12 hours Set up direct FACP AC monitoring from the FACP's main power input with the 5129 Onboard nonsilencing audible alarm Program remotely, view current status, and change the 24 hour test time with a PC running DOS and Silent Knight 5541 software (5530 modem also required) Electrical Specifications Primary AC: 120 VAC, 60 Hz, 45 mA Primary DC: 18-40 VDC Total DC Load: 84 mA @ 24 VDC max Standby Current with Annunciator: 143 mA @ 24 VDC max Standby Current without Annunciator: 84 mA @ 24 VDC max Alarm Current with Annunciator: 227 mA @ 24 VDC max Alarm Current without Annunciator: 154 mA @ 24 VDC max Channel Inputs: 18 - 30 VDC Active High Current: 15 mA max Dry Contact Current: 4.7 VDC, 6 mA max AC Monitor Input (5129 only): AC trouble output from FACP or 120 VAC Watchdog Response: 50 sec. max Mechanical Specifications 5128 Physical Description Dimensions: 4" W x 8.75" H x 1.25" D (10.2 W x 22.2 H x 3.2 D cm) Weight: 2 lbs (0.907 kg) Color: Black 5129 Physical Description Dimensions: 10.1' W x 10.4° H x 3" D (25.7 W x 26.4 H x 7.62 D cm) Weight: 6 lbs (2.7 kg) Color: Red Telephone Requirements: FCC Part 15 approved Type of Jack: RJ31X (two required) LEDs: Green: Power Red: Phone line trouble Yellow: Faulted input and system trouble 5128 5129 Reporting Formats: SK 3/1; Sescoa 3/1; SK 4/2; SK FSK (4/2); Radionics BFSK, Contact ID; & SIA. Approvals NFPA 71 & NFPA 72 UL 864 CSFM 7300-0559:120 MEA 429-92-E Vol. III r SILENT KNIGHT by Hcreyvei 5128/29 Suave Fire Communicator .11 ass ! i. 24 VDC Power + Normally Open Contact Wiring T Fire Alarm Channel 1 Circuit Ground Fire Trouble Channel 2 Circuit Ground Sprinkler Super. Channel 3 Circuit Ground Fire Alarm Channel 4 Circuit Ground Active High Output - - Circuit Ground,E UI.. Listed Local FACP Wiring the 5128129 to a UL Listed Local FACP Ordering Information 5541 Downloading Software 5230 Cable 5128 Slave Fire Communicator Allows for remote programming of the Cable for the 5230 remote annunciator 4 Channel Slave Fire Communicator. 5128/29. Download at no cost from the (PN 130294) used to connect to the For mounting inside FACP cabinet. Silent Knight Web site. 5530 modem 5128,'29 5129 Slave Fire Communicator required. 4 Channel Slave Fire Communicator in Cabinet. For mounting near FACP. Accessories 5230 Remote Annunciator For programming, troubleshooting, and system operations. One per 5128/29. 5530 Modem Modem for use uploading and downloading programming information from 5128/29 and other Silent Knight fire alarm accessories. SILENT This document is not intended to be used for installation purposes. We try to 0 KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are Is subject to change without notice. For more information, contact Silent Knight cy Honeywell 7550 Meridian Circle Suite 100, Maple Grove. Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350780 Rev.B. 05/06 Copyright 2006 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM USTNG LISTING No. 7300-0559:120 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories USTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove MN 55369-4927 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models 5128 dialer card and 5129 digital alarm communicator transmitter. Refer to listee's data sheet for detailed product description and operational considerations. Additional information may be found in the UL Directory. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, and UL label. APPROVAL: Listed as fire alarm accessory devices when used in conjunction with separately listed compatible control unit. Rev. 06-12-2006 'Z This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager 002 11'13/2tJ08 16:56 FAX 909 282 1945 ARROW WIRE & CABLE +ARI:93W Part Number# IBJE2-0 Description: 16 Awg Stranded Bare Copper 1 Twisted Pair UL- FPL Approvals: UL NEC 760 Power limited, fire protective signaling circuit cable UL FPL Conductor: 16 Awg Stranded (26 x.010) Bare Copper per ASTM 00 .059 Insulation: Polyvinyl Chloride (PVC) Wall Thickness: .012 inches Nominal Nominal 00: .080 Inches Core Assembly: 2 Conductors twisted Color Code: Black, Red Jacket: Black Polyvinyl Chloride (PVC) Wall Thickness: .025 Inches Nominal OD: .210 Inches D.0 Resistance: 4.35 Ohms/1000 Ft @ 68F Temperature Rating: 75 Degree Celsius Surface Print: 16 Awg (UL) Type CU or FPL 75c Direct Burial, Sunlight Resistant Date: 3-18-06 Corporate Office . 57 Lawson Strat 2366 West Winton Street City of Industry, CA. 91748 Hayward, CA, 94545 800659.3e55 866.227.7699 fax: 825.937.6167 fax 510,2642120 DEC-13-2006 WED 16:42 TEL: 56298813964 6005 South 40.h Street Unit #1 Phoenix, AZ. 85042 $024381030 fax: 602.4$5,1060 NAME: DCASSOCIATES P. 2