HomeMy WebLinkAbout6231 YARROW DR; ; AS090123; PermitCity of Carlsbad Sprinkler Permit Permit No: AS090123 Job Address: 6231 YARROW DR Permit Type: SPRINK Parcel No: 2130502000 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 9/30/2009 Approved: 9/30/2009 Issued: 9/30/2009 Inspector: Project Title: TARGET WAREHOUSE TWO FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: RIF III YARROW DRIVE II LLC 11620 WILSHIRE BLVD #300 LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 --- Fire Protection by Computer Design COSCO Fire Protection, Inc. 321 East Gardena Blvd. Gardena, CA. 90247 (323) 321-5155 MOST fte mowra ARe. Job Name TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Drawing : Off-Site Warehouse Location : 6231 Yarrow Drive, Suite C, Carlsbad, CA. Remote Area : WEST-side Contract : #I5GS-0463 Data File TARGET Whse_K11-2K.wxf .45/z064 s.ci' Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 "A" COSCO Fire Protection, Inc. fd% Page TARGET Warehouse- Carlsbad / K=1 1.2 Sprinklers Date 9-21-09 Hydraulic Design Information Sheet Name - TARGET Warehouse T1029 - Carlsbad Date - 9-21-09 Location - 6231 Yarrow Drive, Suite C, Carlsbad, CA. Building - Off-Site Warehouse System No. - WEST-side Contractor - COSCO FIRE PROTECTION, INC. Contract No. - #15G5-0463 Calculated By - Mike Coughlin Drawing No. - FP-1 Construction: (X) Combustible C ) Non-Combustible Ceiling Height - 251 -0" Occupancy - STORAGE WAREHOUSE w/ Racks & Shelves S (X) NFPA 13 C ) Lt. Haz. Ord.Haz.Gp. Y ( ) NFPA 231 ( ) NFPA 231C C ) Figure S Other T Specific Ruling 0.45 GPM / 2000 sq.ft. E ( ) 1 ( ) ,2 ( Made By TELGIAN ) 3 (X) Ex.Haz. Curve Date 8-6-09 M Area of Sprinkler Operation - 2064 System Type Sprinkler/Nozzle Density - 0.45 M. Wet Make Reliable D Area Per Sprinkler - 100 max. ( ) Dry Model G-XLO E Elevation at Highest Outlet - 24.042' C ) Deluge Size 3/4" S Hose Allowance - Inside - 100 C ) Preaction K-Factor 11.2 I Rack Sprinkler Allowance - N.A. ( ) Other Temp.Rat.= 165 G Hose Allowance - Outside - 400 N Note = 25 Flowing Sprinklers Calculation Flow Required - 1635.41 Press Required - 91.395 Summary C-Factor Used: 120 Overhead 140 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 4-15-08 Cap. - T Time of Test - N.A. Rated Cap.- Elev.- E Static Press - 124 8 Press - R Residual Press - 118 Elev. - Well Flow - 1060 Proof Flow S Elevation - -18.0' U P Location - 6231 Yarrow Dr., Carlsbad Fire Dept. P NOTE: Hydr. Calc.s input = Reduced by 10% L Source of Information - "Flow Test" by West Coast Fire Prot. (3-2-09) Y per Brenda 8 Carlsbad Fire Dept. (8-25-09) C Commodity Retail Products Storage Class I-IV w/ Location O Storage Ht. 151 -0"' Area 8' Aisle W. M Storage Method: Solid Piled % Palletized 80 % Rack M Single Row (X) Conven. Pallet C ) Auto. Storage (X) Encap. S R (X) Double Row C ) Slave Pallet C ) Solid Shelf C ) Non T A C ) Mult. Row (X) Open Shelf O C R K Flue Spacing 0-8" Clearance:Storage to Ceiling 81 -0" A Longitudinal Transverse G E Horizontal Barriers Provided: >> See attached TARGET plan: F911 water supply Uurve (U) COSCO Fire Protection, Inc. Page 2 TARGET Warehouse- Carlsbad / K=1 1.2 Sprinklers Date 9-21-09 City Water Suppy: Demand: Cl - Static ressure : 111.6 Dl - Elevation : 19.508 C2 - Residual Pressure: 105.6 Wck4er F(oi (o4+ci( D2 - System Flow : 1135.41 D2 - System Pressure : 91.395 C2 - Residual Flow : 1060 o.i -.e_c..Ly '10% t-Q.Q(1JC_cL. Hose (Adj City) Hose ( Demand) : 500 D3 - System Demand : 1635.41 Safety Margin : 6.822 150 140 130 P 120 Cl R 110 E 100 S90 S80 U 70 R 60 E 50 40 30 20 Dl 10 UU 400 600 800 1000 1200 1400 1600 1800 FLOW( N ' 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary COSCO Fire Protection, Inc. Page 3 TARGET Warehouse- Carlsbad / K=1 1.2 Sprinklers Date 9-21-09 Fitting Legend Abbrev. Name % 1 1Y4 1% 2 21/2 3 31,4 4 5 6 8 10 12 14 16 18 20 24 Ala Generic Alarm Valve 0 0 0 0 0 0 7.7 21.5 0 17 17 27 29 0 0 0 0 0 0 0 F 45Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90 Eli Grvd-Vic#10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 M Medium Turn Elbow 0 2 2 3 3 4 5 6 6 8 10 12 16 19 22 0 0 0 0 0 1 90 Flow Thru Tee 3 4 5 6 .8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 — . AN U, ModelGXLO bl.i: :.Sprinkler Extra Large Orifice Extra Large Orifice Sprinkler (SIN R2921) Features 6. Also includes additional Specific Application listing. (See detailed "UL Specification Application listing" described on the back page.) Listings & Approvals: Usted by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories' of Canada (ULC) Approved by Factory Mutual (FM) NYC MEA 258-93-E (NFPA 13*). UL Guide Number VNIV UL Listing Category Sprinklers, Automatic & Open Extra Large Orifice Upright Sprinkler and Specific Application Sprinkler. Technical Data Sprinkler l.N2!]]! K Factor. Sprinkler Sprinkler Type US Metric Wight APxovale Identification Number (SIN) Upright 0.64 Orifice with 160 3.14 (80mm) R2921 1,2,3,4 3/4 NFT(R3A) Upright Retrofit 1 3.25 0.64 Orifice with 11.2 160 (83mm) 1,2,3,4 R2921 ½ NPT(R½) j_ Note: This product has been tested and listed for storage appli- cations to qualify its use in lieu of 5.6K or 8.0K Factor sprinklers for the protection of high-piled storage. Product Description The Reliable Model G XLO sprinkler is a center strut solder in compression extra large orifice upright sprinkler that has been designed to control high chal- lenge fires in both palletized and rack storage occu- pancies utilizing relatively low water pressures. This sprinkler is available with either the standard % NPT (R3/4) threads for new installations or with X NPT (R½) threads for retrofit applications. It has been proven in full-scale fire testing, has com- plied with the applicable mechanical and hydraulic sections of the latest sprinkler standards and has Fac- tory Mutual Approval and Underwriters Laboratories and Underwriters Laboratories' of Canada Listings. This product is intended for use as a standard spray sprinkler in hydraulically designed systems with a minimum pressure of 7 psi (0.5 bar) in accor- dance with the area/density curves of NFPA 13* stan- dards and for all area/density methods of design as referenced by Factory Mutual (FM) Prevention Data Sheets. Design Criteria The following critea apply when designing an automatic sprin- kler system utilizing the Model C XLO sprinkler for NFPA 13* applications. Sprinkler spacing shall be a minimum of 6 ft (1.8m) Sprinklers with Y2 NPT (R½) are to be used for retrofit applications only. Sprinkler discharge pressure per NFPA 13* standards shall be a minimum of 7 psi (0,5 bar). Sprinkler discharge pressure for NFPA 13* standard and all Factory Mutual (FM) applications shall be a minimum of 10 psi (0.7 bar). Factory Mutual (FM) Loss Prevention Data Sheets contain requirements which differ from NFPA. The Model C XLO is Approved by Factory Mutual for all area/density methods of design as referenced by FM Loss Prevention Data Sheets. The Model C XLO Extra Large Orifice sprinkler is intended for standard flow/pressure requirements and standard place- ment as specified for NFPA storage requirements. The Model C XLO sprinkler is not a "Large Drop" or "ESFR" sprinkler. Temperature Ratinus Sprinkler Maximum Ambient Classification Rating Temperature Frame Color "F "C "F "C Ordinary 165 I 74 100 38 Uncolored Intermediate High 212 286 I 100 141 150 1 225 I 66 107 White Blue * For sprinkler standards prior to 1999 edition of NFPA 13, use NFPA standards 231, 231C, 231D & 231F. The Reliable Model G XLO sprinkler offers the opportunity for: Pipe size reduction Fewer sprinklers _._3EnEationoLboQsteLpumps_------------ Increasing densities with existing systems )/ NPT (R½) available for retrofit installations only The Reliable Automatic Sprinkler Co., Inc. '525 North MacQuesten Parkway • Mount Vernon New York '10552 Finishes Standard Finishes Bronze Chrome Special Application Finishes Lead Plated t' -165 F(74 C), 212 F (100 C) and 286 F(141 C)Ternp. Ratings Wax - 165 F (74 C) Clear Wax, 212 F (100 C) Brown Wax Wax/Lead - 165 F(74 C) Clear Wax, 212 F(100 C) Brown Wax UL Listed only. 212 F (100 C) Brown wax may be used on 286 F (141 C) Sprinklers when maximum ambient temperatures do not exceed 150 F (56 C). Maintenance Model G XLO Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other Cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprin}ders that would cause improper opera- tion or non-operation. Ordering Information Specify: The UL Specific Application Listing is: 1. Sprinkler Model The Model GXLO uprht spri n 2. Temperature Rating - - - ..- --- - accordance with the standard sprinkler positioning and area/density flow calculation requirements as specified in each respective standard. Model G XLO upright sprinklers may also be installed to protect single, double and multiple - Model H Sprinkler Wrench row and portable rack storage of Class l-IV, Groups A and B plastics, cartoned, expanded or unexpanded, as well as exposed unexpanded with amaximum storage height of 20 ft. (6.5m), maximum ceiling height of 25 ft (8.2rn) or27' ft (8.8m) - maximum ceiling height, 36 (914mm) minimum deflector to top of storage clearance, design density of 0.60 gprrV ft2. (24.7 Lithiri/m2), and a design area of 2000 ft2. (186m2) for wet Systems and 2600 ff. (242-n2) for dry systems. - Use only the Model H sprinkler wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Note: Maximum 27ft ceilling height is allowed by NFPA 13*, Mthout in-rack sprinklers in a protected area, provided the ceiling sprinklers' discharge is increased to 0.6 gprrilft2 in a 2000 ft2 design area. Installation Reliable's Model G XLO sprinkler must be installed according to NFPA Standards or the appropriate Factory Mutual Loss Prevention Data Sheets for all area/density methods of design as well as the Authority Having Jurisdiction. The Model GXLO sprinkler meets the NFPA 13* code stan-dards for approval by Factory Mutual and listings by Under- writers Laboratories & Underwriters Laboratories of Canada * For sprinkler standards prior to 1999 edition of NFPA 13, use NFPA standards 231,231C, 2310 & 231F. (r/2' ivPT) 222" 3.25" (7/2 NPT) [77.6mm] [s2.e,,m] N12T) 2.71" (/4" kPT) [rB8mmJ RASCO fJ9.&nnj 727" (47.5mm] The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for 0ver80 years, and are installed and serviced bythe most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800)848-6051 Sales Fax (914) 668-3470 Corporate Offices www.reliablesprinkler.com Internet Address Revision lines indicate updated or new data. PG. Printed in U.S.A. 06iV2 P/N9999970022 Pressure I Flow Summary - STANDARD COSCO Fire Protection, Inc. Page 4 TARGET Warehouse- Carlsbad I K=11.2 Sprinklers Date 9-21-09 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 101 21.917 24.57 na W1L 21.917 21.22 na Wi 24.042 11.2 16.24 na 45.13 0.45 72.664 8.524 W21- 21.917 20.95 na W2 24.042 11.2 16.02 na 44.83 0.45 72.664 8.524 WK 21.917 20.85 na W3 24.042 11.2 15.94 na 44.72 0.45 72.664 8.524 W41- 21.917 20.84 na W4 24.042 11.2 15.93 na 44.7 0.45 72.664 8.524 W51- 21.917 20.86 na W5 24.042 11.2 15.95 na 44.73 0.45 72.664 8.524 W61- 21.917 20.98 na W6 24.042 11.2 16.05 na 44.86 0.45 72.664 8.524 W71- 21.917 21.28 na W7 24.042 11.2 16.29 na 45.2 0.45 72.664 8.524 201 21.917 24.37 na 102 21.917 24.63 na W81- 21.917 21.27 na W8 24.042 11.2 16.28 na 45.19 0.45 72.664 8.524 W91- 21.917 20.82 na W9 24.042 11.2 15.92 na 44.69 0.45 72.664 8.524 W1OL 21.917 20.66 na W10 24.042 11.2 15.78 na 44.5 0.45 72.664 8.524 WilL 21.917 20.64 na Wit 24.042 11.2 15.77 na 44.48 0.45 72.664 8.524 W12L 21.917 20.67 na W12 24.042 11.2 15.79 na 44.51 0.45 72.664 8.524 W13L 21.917 20.87 na W13 24.042 11.2 15.96 na 44.74 0.45 72.664 8.524 W14L 21.917 21.36 na W14 24.042 11.2 16.36 na 45.3 0.45 72.664 8.524 202 21.917 24.43 na 103 21.917 24.87 na W1 5L 21.917 21.48 na W15 24.042 11.2 16.45 na 45.43 0.45 100 16.143 W16L 21.917 21.21 na W16 24.042 11.2 16.23 na 45.13 0.45 100 16.143 W17L 21.917 21.11 na W17 24.042 11.2 16.15 na 45.01 0.45 100 16.143 W18L 21.917 21.1 na W18 24.042 11.2 16.14 na 45.0 0.45 100 16.143 W1 9L 21.917 21.12 na W19 24.042 11.2 16.16 na 45.02 0.45 100 16.143 W20L 21.917 21.24 . na W20 24.042 11.2 16.26 na 45.16 0.45 100 16.143 W21L 21.917 21.55 na W21 24.042 11.2 16.51 na 45.5 0.45 100 16.143 203 21.917 24.69 na 104 21.917 25.43 na W22L 21.917 24.15 na W22 24.042 23.23 na W23L 21.917 23.95 na W23 24.042 23.03 na W24L 21.917 23.76 na W24 24.042 11.2 18.3 na 47.92 0.45 100 16.143 W25L 21.917 23.71 na W25 24.042 11.2 18.26 na 47.86 0.45 100 16.143 W26L 21.917 23.71 na W26 24.042 11.2 18.26 na 47.86 0.45 100 16.143 W27L 21.917 23.78 na W27 24.042 11.2 18.32 na 47.94 0.45 100 16.143 W28L 21.917 24.01 na W28 24.042 23.09 na 204 21.917 25.3 na 105 21.917 26.22 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard COSCO Fire Protection, Inc. TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Node Elevation K-Fact Pt Rn Flow No. Actual Actua Page 5 Date 9-21-09 Density Area Press W29L 21.917 26.2 na W29 24.042 25.28 na W30L 21.917 26.2 na W30 24.042 25.28 na W31 21.917 26.2 na W31 24.042 25.28 na W32L 21.917 26.19 na W32 24.042 25.27 na W33L 21.917 26.19 na W33 24.042 25.27 na W34L 21.917 26.19 na W34 24.042 25.27 na W35L 21.917 26.19 na W35 24.042 25.26 na 205 21.917 26.17 na 106 21.917 27.03 na 206 21.917 27.02 na 107 21.917 27.85 na 207 21.917 27.85 na 108 21.917 28.68 na 208 21.917 28.68 na 109 21.917 29.5 na 209 21.917 29.5 na 110 21.917 30.33 na 210 21.917 30.33 na 111 21.917 31.16 na 211 21.917 31.16 na 112 21.917 31.99 na 212 21.917 31.99 na 113 21.917 32.81 na 213 21.917 32.81 na 114 21.917 33.64 na 214 21.917 33.64 na 115 21.917 34.49 na 215 21.917 34.49 na 116 21.917 35.32 na 216 21.917 35.32 na 117 21.917 36.15 na 217 21.917 36.15 na 118 21.917 36.97 na 218 21.917 36.97 na 119 21.917 37.8 na 219 21.917 37.8 na 120 21.917 38.63 na 220 21.917 38.63 na 121 21.917 39.46 na 221 21.917 39.46 na 122 21.917 40.29 na 222 21.917 40.28 na 123 21.917 41.12 na 223 21.917 41.1 na 124 21.917 41.95 na 224 21.917 41.92 na 125 21.917 42.79 na 225 21.917 42.74 na 126 21.917 43.64 na 226 21.917 43.55 na 127 21.917 44.37 na 227 21.917 4422 na 128 21.917 45.7 na 228 21.917 45.42 na 328 21.917 51.24 na R-T 21.917 51.79 na R-B 0.5 63.02 na 100.0 U -3.5 65.89 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard COSCO Fire Protection, Inc. Page 6 TARGET Warehouse- Carlsbad / K=11.2 Sprinklers Date 9-21-09 Node Elevation K-Fact Pt Pn Flow Density Area Press No. tual Actual Rea. U2 -18.0 77.26 na BF1 -21.0 80.56 na BF2 -21.0 88.63 na U3 -21.0 89.43 na SOR -21.0 91.4 na The maximum velocity is 17.8 and it occurs in the pipe between nodes W27 and W27L Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 400.0 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 7 TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 101 153.56 4.26 0.0 8.417 24.574 to 120 0.0 0.0 0.0 102 153.56 0.0061 0.0 8.417 0.051 Vel = 3.46 0.0 153.56 24.625 KFactor= 30.94 W1L 153.56 2.635 IT 16.474 36.250 21.216 to 120 0.0 16.474 0.0 101 153.56 0.0637 0.0 52.724 3.358 Vel = 9.03 0.0 153.56 24.574 K Factor= 30.98 W1 45.13 1.049 IT 5.0 1.917 16.239 K Factor= 11.20 to 120 0.0 5.000 0.920 W1L 45.13 0.5865 0.0 6.917 4.057 Vel = 16.75 0.0 45.13 21.216 KFactor= 9.80 WK 108.42 2.635 0.0 8.000 20.948 to 120 0.0 0.0 0.0 W1L 108.42 0.0335 0.0 8.000 0.268 Vel = 6.38 0.0 108.42 21.216 KFactor= 23.54 W2 44.83 1.049 IT 5.0 1.917 16.021 K Factor= 11.20 to 120 0.0 5.000 0.920 W2L 44.83 0.5793 0.0 6.917 4.007 Vel = 16.64 0.0 44.83 20.948 KFactor= 9.79 WK 63.59 2.635 0.0 8.000 20.849 to 120 0.0 0.0 0.0 W2L 63.59 0.0124 0.0 8.000 0.099 Vel = 3.74 0.0 63.59 20.948 KFactor= 13.89 W3 44.72 1.049 IT 5.0 1.917 15.940 K Factor= 11.20 to 120 0.0 5.000 0.920 WK 44.72 0.5767 0.0 6.917 3.989 Vel = 16.60 0.0 44.72 20.849 K Factor = 9.79 W4L 18.88 2.635 0.0 8.000 20.838 to 120 0.0 0.0 0.0 WK 18.88 0.0014 0.0 8.000 0.011 Vel= 1.11 0.0 18.88 20.849 KFactor= 4.13 W4 44.70 1.049 IT 5.0 1.917 15.932 K Factor= 11.20 to 120 0.0 5.000 0.920 W4L 44.7 0.5763 0.0 6.917 3.986 Vel = 16.59 0.0 44.70 20.838 K Factor = 9.79 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 8 TARGET Warehouse- Carlsbad / K=11.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W5L -25.83 2.635 0.0 8.000 20.857 to . 120 0.0 0.0 0.0 W4L -25.83 -0.0024 0.0 8.000 -0.019 Vel = 1.52 0.0 -25.83 20.838 K Factor= -5.66 W5 44.73 1.049 IT 5.0 1.917 15.947 K Factor= 11.20 to 120 0.0 5.000 0.920 W5L 44.73 0.5768 0.0 6.917 3.990 Vel = 16.60 0.0 44.73 20.857 K Factor = 9.79 W6L -70.55 2.635 0.0 8.000 20.978 to 120 0.0 0.0 0.0 W5L -70.55 -0.0151 0.0 8.000 -0.121 Vel = 4.15 0.0 -70.55 20.857 K Factor = -15.45 W6 44.86 1.049 IT 5.0 1.917 16.045 K Factor= 11.20 to 120 0.0 5.000 0.920 W6L 44.86 0.5802 0.0 6.917 4.013 Vet = 16.65 0.0 44.86 20.978 K Factor= 9.79 W7L -115.42 2.635 0.0 8.000 2.1.278 to 120 0.0 0.0 0.0 W6L -115.42 -0.0375 0.0 8.000 -0.300 Vel = 6.79 0.0 -115.42 20.978 K Factor = -25.20 W7 45.20 1.049 1T 5.0 1.917 16.289 K Factor = 11.20 to 120 0.0 5.000 0.920 W7L 45.2 0.5883 0.0 6.917 4.069 Vel = 16.78 0.0 45.20 21.278 K Factor = 9.80 201 -160.62 2.635 iT 16.474 28.250 24.374 to 120 0.0 16.474 0.0 W7L -160.62 -0.0692 0.0 44.724 -3.096 Vel = 9.45 0.0 -160.62 21.278 K Factor = -34.82 201 160.62 4.26 0.0 8.417 24.374 to 120 0.0 0.0 0.0 202 160.62 0.0067 0.0 8.417 0.056 Vel = 3.62 0.0 160.62 24.430 K Factor= 32.50 102 307.08 4.26 0.0 10.875 24.625 to 120 0.0 0.0 0.0 103 307.08 0.0222 0.0 10.875 0.241 Vel = 6.91 0.0 307.08 24.866 KFactor= 61.58 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 9 TARGET Warehouse- Carlsbad / K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W8L 153.52 2.635 IT 16.474 36.250 21.269 to 120 0.0 16.474 0.0 102 153.52 0.0637 0.0 52.724 3.356 Vel = 9.03 0.0 153.52 24.625 KFactor= 30.94 W8 45.19 1.049 IT 5.0 1.917 16.282 K Factor= 11.20 to 120 0.0 5.000 0.920 W8L 45.19 0.5880 0.0 6.917 4.067 Vel = 16.78 0.0 45.19 21.269 K Factor = 9.80 W9L 108.33 2.635 0.0 13.333 20.824 to 120 0.0 0.0 0.0 W8L 108.33 0.0334 0.0 13.333 0.445 Vel = 6.37 0.0 108.33 21.269 K Factor= 23.49 W9 44.69 1.049 IT 5.0 1.917 15.920 K Factor= 11.20 to 120 0.0 5.000 0.920 W9L 44.69 0.5760 0.0 6.917 3.984 Vel = 16.59 0.0 44.69 20.824 K Factor = 9.79 W1OL 63.65 2.635 0.0 13.333 20.657 to 120 0.0 0.0 0.0 W9L 63.65 0.0125 0.0 13.333 0.167 Vel = 3.74 0.0 63.65 20.824 K Factor= 13.95 WIO 44.50 1.049 1 5.0 1.917 15.785 K Factor= 11.20 to 120 0.0 5.000 0.920 W1OL 44.5 0.5713 0.0 6.917 3.952 Vel = 16.52 0.0 44.50 20.657 K Factor = 9.79 WilL 19.15 2.635 0.0 13.333 20.639 to 120 0.0 0.0 0.0 W1OL 19.15 0.0014 0.0 13.333 0.018 Vel = 1.13 0.0 19.15 20.657 K Factor = 4.21 Wil 44.48 1.049 IT 5.0 1.917 15.770 K Factor= 11.20 to 120 0.0 5.000 0.920 - WilL 44.48 0.5709 0.0 6.917 3.949 Vel = 16.51 0.0 44.48 20.639 K Factor = 9.79 W12L -25.33 2.635 0.0 13.333 20.669 to 120 0.0 0.0 0.0 WilL -25.33 -0.0023 0.0 13.333 -0.030 Vel = 1.49 0.0 -25.33 20.639 K Factor= -5.58 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 10 TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W12 44.51 1.049 iT 5.0 1.917 15.795 K Factor = 11.20 to 120 0.0 5.000 0.920 W12L 44.51 0.5716 0.0 6.917 3.954 Vel= 16.52 0.0 44.51 20.669 K Factor = 9.79 W1 3L -69.84 2.635 0.0 13.333 20.867 to 120 0.0 0.0 0.0 W1 2L -69.84 -0.0149 0.0 13.333 -0.198 Vel = 4.11 0.0 -69.84 20.669 K Factor = -15.36 W13 44.74 1.049 1 5.0 1.917 15.955 K Factor = 11.20 to 120 0.0 5.000 0.920 W1 3L 44.74 0.5771 0.0 6.917 3.992 Vel = 16.61 0.0 44.74 20.867 K Factor = 9.79 W14L -114.58 2.635 0.0 13.333 21.361 to 120 0.0 0.0 0.0 W1 3L -114.58 -0.0371 0.0 13.333 -0.494 Vel = 6.74 0.0 -114.58 20.867 K Factor = -25.08 W14 45.30 1.049 iT 5.0 1.917 16.356 K Factor = 11.20 to 120 0.0 5.000 0.920 -W14L 45.3 0.5906 0.0 6.917 4.085 Vel = 16.82 0.0 45.30 21.361 K Factor = 9.80 202 -159.87 2.635 1 16.474 28.250 24.430 to 120 0.0 16.474 0.0 W14L -159.87 -0.0686 0.0 44.724 -3.069 Vel = 9.41 0.0 -159.87 21.361 K Factor = -34.59 202 320.50 4.26 0.0 10.875 24.430 to 120 0.0 0.0 0.0 203 320.5 0.0239 0.0 10.875 0.260 Vel = 7.21 0.0 320.50 24.690 K Factor = 64.50 103 461.37 4.26 0.0 12.000 24.866 to 120 0.0 0.0 0.0 104 461.37 0.0470 0.0 12.000 0.564 Vel = 10.39 0.0 461.37 25.430 K Factor = 91.49 W15L 154.29 2.635 IT 16.474 36.250 21.479 to 120 0.0 16.474 0.0 103 154.29 0.0642 0.0 52.724 3.387 Vel = 9.08 0.0 154.29 24.866 KFactor= 30.94 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 11 TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W15 45.43 1.049 iT 5.0 1.917 16.452 K Factor = 11.20 to 120 0.0 5.000 0.920 W1 5L 45.43 0.5938 0.0 6.917 4.107 Vel = 16.86 0.0 45.43 21.479 K Factor = 9.80 W16L 108.86 2.635 0.0 8.000 21.209 to 120 0.0 0.0 0.0 W1 5L 108.86 0.0338 0.0 8.000 0.270 Vel = 6.40 0.0 108.86 21.479 K Factor = 23.49 W16 45.12 1.049 iT 5.0 1.917 16.233 K Factor= 11.20 to 120 0.0 5.000 0.920 W16L 45.12 0.5864 0.0 6.917 4.056 Vel = 16.75 - 0.0 45.12 21.209 KFactor= 9.80 W17L 63.73 2.635 0.0 8.000 21.109 to 120 0.0 0.0 0.0 W16L 63.73 0.0125 0.0 8.000 0.100 Vel = 3.75 0.0 63.73 21.209 K Factor= 13.84 W17 45.01 1.049 iT 5.0 1.917 16.152 K Factor = 11.20 to 120 0.0 5.000 0.920 W1 7L 45.01 0.5836 0.0 6.917 4.037 Vel = 16.71 0.0 45.01 21.109 K Factor = 9.80 W18L 18.72 2.635 0.0 8.000 21.098 to 120 0.0 0.0 0.0 W17L 18.72 0.0014 0.0 8.000 0.011 Vel= 1.10 0.0 18.72 21.109 KFactor= 4.07 W18 45.00 1.049 iT 5.0 1.917 16.143 K Factor= 11.20 to 120 0.0 5.000 0.920 W18L 45.0 0.5833 0.0 6.917 4.035 Vel = 16.71 0.0 45.00 21.098 K Factor = 9.80 W19L -26.28 2.635 0.0 8.000 21.118 to 120 0.0 0.0 0.0 W1 8L -26.28 -0.0025 0.0 8.000 -0.020 Vel = 1.55 0.0 -26.28 21.098 KFactor= -5.72 W19 45.02 1.049 iT 5.0 1.917 16.159 K Factor= 11.20 to 120 0.0 5.000 0.920 W19L 45.02 0.5839 0.0 6.917 4.039 Vel= 16.71 0.0 45.02 21.118 KFactor= 9.80 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 12 TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W20L -71.30 2.635 0.0 8.000 21.241 to 120 0.0 0.0 0.0 WI9L -71.3 -0.0154 0.0 8.000 -0.123 Vel = 4.19 0.0 -71.30 21.118 K Factor = -15.52 W20 45.16 1.049 iT 5.0 1.917 16.259 K Factor = 11.20 to 120 0.0 5.000 0.920 W20L 45.16 0.5872 0.0 6.917 4.062 Vel = 16.76 0.0 45.16 21.241 KFactor= 9.80 W21 -116.46 2.635 0.0 8.000 21.547 to 120 0.0 0.0 0.0 W20L -116.46 -0.0382 0.0 8.000 -0.306 Vel = 6.85 0.0 -116.46 21.241 K Factor = -25.27 W21 45.50 1.049 IT 5.0 1.917 16.507 K Factor= 11.20 to 120 0.0 5.000 0.920 W21 45.5 0.5956 0.0 6.917 4.120 Vel= 16.89 0.0 45.50 21.547 K Factor = 9.80 203 -161.97 2.635 1 16.474 28.250 24.690 to 120 0.0 16.474 0.0 W21 -161.97 -0.0703 0.0 44.724 -3.143 Vel = 9.53 0.0 -161.97 21.547 K Factor = -34.89 203 482.46 4.26 0.0 12.000 24.690 to 120 0.0 0.0 0.0 204 482.46 0.0511 0.0 12.000 0.613 Vel = 10.86 0.0 482.46 25.303 K Factor= 95.91 104 552.70 4.26 0.0 12.000 25.430 to 120 0.0 0.0 0.0 105 552.7 0.0656 0.0 12.000 0.787 Vel = 12.44 0.0 552.70 26.217 K Factor 107.94 W22L 91.33 2.635 iT 16.474 36.250 24.146 to 120 0.0 16.474 0.0 104 91.33 0.0244 0.0 52.724 1.284 Vel= 5.37 0.0 91.33 25.430 K Factor= 18.11 W22 0.0 1.049 iT 5.0 1.917 23.225 to 120 0.0 5.000 0.920 W22L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 24.146 K Factor =0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 13 TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W23L 91.33 2.635 0.0 8.000 23.951 to 120 0.0 0.0 0.0 W22L 91.33 0.0244 0.0 8.000 0.195 Vel = 5.37 0.0 91.33 24.146 KFactor= 18.59 W23 0.0 1.049 IT 5.0 1.917 23.030 to 120 0.0 5.000 0.920 W23L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 23.951 K Factor =0 W24L 91.33 2.635 0.0 8.000 23.756 to 120 0.0 0.0 0.0 W23L 91.33 0.0244 0.0 8.000 0.195 Vel = 5.37 0.0 91.33 23.951 KFactor= 18.66 W24 47.92 1.049 1 5.0 1.917 18.304 KFactor= 11.20 to 120 0.0 5.000 0.920 W24L 47.92 0.6552 0.0 6.917 4.532 Vel = 17.79 0.0 47.92 - 23.756 K Factor = 9.83 W25L 43.42 2.635 0.0 8.000 23.707 to 120 0.0 0.0 0.0 W24L 43.42 0.0061 0.0 8.000 0.049 Vel = 2.55 0.0 43.42 23.756 K Factor = 8.91 W25 47.86 1.049 1 5.0 1.917 18.264 K Factor = 11.20 to 120 0.0 5.000 0.920 W25L 47.86 0.6539 0.0 6.917 4.523 Vel = 17.77 0.0 47.86 23.707 K Factor = 9.83 W26L -4.45 2.635 0.0 8.000 23.707 to 120 0.0 0.0 0.0 W25L -4.45 0.0 0.0 8.000 0.0 Vel = 0.26 0.0 -4.45 23.707 K Factor = -0.91 W26 47.86 1.049 IT 5.0 1.917 18.264 K Factor = 11.20 to 120 0.0 5.000 0.920 W26L 47.86 0.6539 0.0 6.917 4.523 Vel = 17.77 0.0 47.86 . 23.707 K Factor = 9.83 W27L -52.31 2.635 0.0 8.000 23.777 to 120 0.0 0.0 0.0 W26L -52.31 -0.0088 0.0 8.000 -0.070 Vel = 3.08 0.0 -52.31 23.707 K Factor = -10.74 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 14 TARGET Warehouse- Carlsbad / K=l 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W27 47.94 1.049 iT 5.0 1.917 18.321 K Factor= 11.20 to 120 0.0 5.000 0.920 W27L 47.94 0.6558 0.0 6.917 4.536 Vel = 17.80 0.0 47.94 23.777 K Factor = 9.83 W28L -100.25 2.635 0.0 8.000 24.008 to 120 0.0 0.0 0.0 W27L -100.25 -0.0289 0.0 8.000 -0.231 Vel = 5.90 0.0 -100.25 23.777 K Factor = -20.56 W28 0.0 1.049 iT 5.0 1.917 23.088 to 120 0.0 5.000 0.920 W28L 0.0 0.0 0.0 6.917 0.0 Vel =0 0.0 0.0 24.008 K Factor = 0 204 -100.25 2.635 iT 16.474 28.250 25.303 to 120 0.0 16.474 0.0 W28L -100.25 -0.0290 0.0 44.724 -1.295 Vet = 5.90 0.0 -100.25 24.008 K Factor = -20.46 204 582.71 4.26 0.0 12.000 25.303 to 120 0.0 0.0 0.0 205 582.71 0.0723 0.0 12.000 0.868 Vet = 13.12 0.0 582.71 26.171 K Factor = 113.90 105 561.45 4.26 0.0 12.000 26.217 to 120 0.0 0.0 0.0 106 561.45 0.0676 0.0 12.000 0.811 Vel = 12.64 0.0 561.45 27.028 K Factor = 108.00 W29L 8.75 2.635 IT 16.474 36.250 26.200 to 120 0.0 16.474 0.0 105 8.75 0.0003 0.0 52.724 0.017 Vel = 0.51 0.0 8.75 26.217 K Factor= 1.71 W29 0.0 1.049 IT 5.0 1.917 25.280 to 120 0.0 5.000 0.920 W29L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 26.200 K Factor = 0 W30L 8.75 2.635 0.0 8.000 26.198 to 120 0.0 0.0 0.0 W29L 8.75 0.0002 0.0 8.000 0.002 Vel = 0.51 0.0 8.75 26.200 K Factor = 1.71 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 15 TARGET Warehouse- Carlsbad / K=l 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W30 0.0 1.049 IT 5.0 1.917 25.278 to 120 0.0 5.000 0.920 W30L 0.0 0.0 0.0 6.917 0.0 Vel0 0.0 0.0 26.198 K Factor =0 W31 8.75 2.635 0.0 8.000 26.195 to 120 0.0 0.0 0.0 W30L 8.75 0.0004 0.0 8.000 0.003 Vet = 0.51 0.0 8.75 26.198 K Factor= 1.71 W31 0.0 1.049 IT 5.0 1.917 25.275 to 120 0.0 5.000 0.920 W31 0.0 0.0 0.0 - 6.917 0.0 Vet = 0 0.0 0.0 26.195 K Factor =0 W32L 8.75 2.635 0.0 8.000 26.193 to 120 0.0 0.0 0.0 W31 8.75 0.0002 0.0 8.000 0.002 Vel = 0.51 0.0 8.75 26.195 KFactor=1.71 W32 0.0 1.049 1 5.0 1.917 25.272 to 120 0.0 5.000 0.920 W32L0.00.0001 0.06.9170.001 Vel =0 0.0 0.0 26.193 K Factor= 0 W33L 8.75 2.635 0.0 8.000 26.190 to 120 0.0 0.0 0.0 W32L 8.75 0.0004 0.0 8.000 0.003 Vel = 0.51 0.0 8.75 26.193 K Factor= 1.71 W33 0.0 1.049 IT 5.0 1.917 25.270 to 120 0.0 5.000 0.920 W33L 0.0 0.0 0.0 6.917 0.0 Vet = 0 0.0 0.0 26.190 KFactor =0 W34L 8.75 2.635 0.0 8.000 26.188 to 120 0.0 0.0 0.0 W33L 8.75 0.0002 0.0 8.000 0.002 Vet = 0.51 0.0 8.75 26.190 KFactor= 1.71 W34 0.0 1.049 IT 5.0 1.917 25.267 to 120 0.0 5.000 0.920 W34L 0.0 0.0001 0.0 -6.9170.001 Vel =0 0.0 0.0 26.188 K Factor =0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 16 TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W35L 8.75 2.635 0.0 8.000 26.185 to 120 0.0 0.0 0.0 W34L 8.75 0.0004 0.0 8.000 0.003 Vel = 0.51 0.0 8.75 26.188 KFactor= 1.71 W35 0.0 1.049 IT 5.0 1.917 25.265 to 120 0.0 5.000 0.920 W35L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 26.185 K Factor =0 205 8.75 2.635 IT 16.474 28.250 26.171 to 120 0.0 16.474 0.0 W35L 8.75 0.0003 0.0 44.724 0.014 Vel = 0.51 0.0 8.75 26.185 KFactor= 1.71 205 573.96 4.26 0.0 12.000 26.171 to 120 0.0 0.0 0.0 206 573.96 0.0703 0.0 12.000 0.844 Vel = 12.92 0.0 573.96 27.015 K Factor = 110.43 106 565.76 4.26 0.0 12.000 27.028 to 120 0.0 0.0 0.0 107 565.76 0.0685 0.0 12.000 0.822 Vel = 12.74 0.0 565.76 27.850 K Factor= 107.21 206 4.31 2.635 2T 32.948 112.500 27.015 to 120 0.0 32.948 0.0 106 4.31 0.0001 0.0 145.448 0.013 Vel = 0.25 0.0 4.31 27.028 K Factor = 0.83 206 569.65 4.26 0.0 12.000 27.015 to 120 0.0 0.0 0.0 207 569.65 0.0694 0.0 12.000 0.833 VeI= 12.82 0.0 569.65 27.848 K Factor = 107.95 107 567.36 4.26 0.0 12.000 27.850 to 120 0.0 0.0 0.0 108 567.36 0.0688 0.0 12.000 0.826 Vel = 12.77 0.0 567.36 28.676 K Factor = 105.95 207 1.60 2.635 2T 32.948 112.500 27.848 to 120 0.0 32.948 0.0 107 1.6 0.0 0.0 145.448 0.002 Vel = 0.09 0.0 1.60 27.850 K Factor = 0.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 17 TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 207 568.05 4.26 0.0 12.000 27.848 to 120 0.0 0.0 0.0 208 568.05 0.0690 0.0 12.000 0.828 Vet = 12.79 0.0 568.05 28.676 K Factor = 106.08 108 567.69 4.26 0.0 12.000 28.676 to 120 0.0 0.0 0.0 109 567.69 0.0690 0.0 12.000 0.828 Vet = 12.78 0.0 567.69 29.504 K Factor = 104.51 208 0.33 2.635 2T 32.948 112.500 28.676 to 120 0.0 32.948 0.0 108 0.33 0.0 0.0 145.448 0.0 - Vet = 0.02 0.0 0.33 28.676 K Factor = 0.06 208 567.73 4.26 0.0 12.000 28.676 to 120 0.0 0.0 0.0 209 567.73 0.0690 0.0 12.000 0.828 Vet = 12.78 0.0 -567.73 29.504 KFactor =104.52 109 567.71 4.26 0.0 12.000 29.504 to 120 0.0 0.0 0.0 110 567.71 0.0689 - 0.0 12.000 0.827 Vel= 12.78 0.0 567.71 - 30.331 K Factor = 103.08 209 0.02 2.635 2T 32.948 112.500 29.504 to 120 0.0 32.948 0.0 109 0.02 0.0 0.0 145.448 0.0 Vet = 0 0.0 0.02 29.504 K Factor =0 209 567.71 4.26 0.0 12.000 29.504 to 120 0.0 0.0 0.0 210 567.71 0.0689 0.0 12.000 0.827 Vet = 12.78 0.0 567.71 30.331 K Factor = 103.08 110 567.71 4.26 0.0 12.000 30.331 to 120 0.0 0.0 0.0 111 567.71 0.0690 0.0 12.000 0.828 Vet = 12.78 0.0 567.71 31.159 K Factor = 101.70 210 0.0 2.635 2T 32.948 112.500 30.331 to 120 0.0 32.948 0.0 110 0.0 0.0 0.0 145.448 0.0 Vel=0 0.0 0.0 30.331 K Factor =0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 18 TARGET Warehouse- Carlsbad / K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 210 567.71 4.26 0.0 12.000 30.331 to 120 0.0 0.0 0.0 211 567.71 0.0690 0.0 12.000 0.828 Vel = 12.78 0.0 567.71 31.159 K Factor = 101.70 111 567.71 4.26 0.0 12.000 31.159 to 120 0.0 0.0 0.0 112 567.71 0.0689 0.0 12.000 0.827 VeI= 12.78 0.0 567.71 31.986 K Factor = 100.38 211 0.0 2.635 2T 32.948 112.500 31.159 to 120 0.0 32.948 0.0 111 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 31.159 K Factor =0 211 567.71 4.26 0.0 12.000 31.159 to 120 0.0 0.0 0.0 212 567.71 0.0689 0.0 12.000 0.827 Vel = 12.78 0.0 - 567.71 31.986 K Factor= 100.38 112 567.71 4.26 0.0 12.000 31.986 to 120 0.0 0.0 0.0 113 567.71 0.0690 0.0 12.000 0.828 Vel = 12.78 0.0 567.71 32.814 KFactor= 99.11 212 0.0 2.635 21 32.948 112.500 31.986 to 120 0.0 32.948 0.0 112 0.0 0.0 0.0 145.448 0.0 Vel =0 0.0 0.0 31.986 K Factor = 0 212 567.71 4.26 0.0 12.000 31.986 to 120 0.0 0.0 0.0 213 567.71 0.0690 0.0 12.000 0.828 Vel = 12.78 0.0 567.71 32.814 KFactor= 99.11 113 567.71 4.26 0.0 12.000 32.814 to 120 0.0 0.0 0.0 114 567.71 0.0689 0.0 12.000 0.827 Vel = 12.78 0.0 567.71 33.641 K Factor= 97.88 213 0.0 2.635 21 32.948 112.500 32.814 to 120 0.0 32.948 0.0 113 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 32.814 K Factor =0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 19 TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 213 567.71 4.26 0.0 12.000 32.814 to 120 0.0 0.0 0.0 214 567.71 0.0689 0.0 12.000 0.827 Vel= 12.78 0.0 567.71 33.641 KFactor= 97.88 114 567.71 4.26 0.0 12.333 33.641 to 120 0.0 0.0 0.0 115 567.71 0.0690 0.0 12.333 0.851 Vel= 12.78 0.0 567.71 34.492 KFactor= 96.66 214 0.0 2.635 21 32.948 112.500 33.641 to 120 0.0 32.948 0.0 114 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 33.641 K Factor =0 214 567.71 4.26 0.0 12.333 33.641 to 120 0.0 0.0 0.0 215 567.71 0.0690 0.0 12.333 0.851 Vel = 12.78 0.0 567.71 34.492 KFactor= 96.66 115 567.71 4.26 0.0 12.000 34.492 to 120 0.0 0.0 0.0 116 567.71 0.0689 0.0 12.000 0.827 Vel = 12.78 0.0 567.71 35.319 K Factor= 95.53 - 215 0.0 1.61 21 16.0 112.500 34.492 to 120 0.0 16.000 0.0 115 0.0 0.0 0.0 128.500 0.0 Vel = 0 0.0 0.0 34.492 K Factor =0 215 567.71 4.26 0.0 12.000 34.492 to 120 0.0 0.0 0.0 216 567.71 0.0689 0.0 12.000 0.827 Vel = 12.78 0.0 567.71 35.319 KFactor= 95.53 116 567.71 4.26 0.0 12.000 35.319 to 120 0.0 0.0 0.0 117 567.71 0.0689 0.0 12.000 0.827 Vel= 12.78 0.0 567.71 36.146 KFactor= 94.43 216 0.0 1.61 21 16.0 112.500 35.319 to 120 0.0 16.000 0.0 116 0.0 0.0 0.0 128.500 0.0 Vel =0 0.0 0.0 35.319 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 20 TARGET Warehouse- Carlsbad I K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 216 567.71 4.26 0.0 12.000 35.319 to 120 0.0 0.0 0.0 217 567.71 0.0689 0.0 12.000 0.827 Vel = 12.78 0.0 567.71 36.146 KFactor= 94.43 117 567.71 4.26 0.0 12.000 36.146 to 120 0.0 0.0 0.0 118 567.71 0.0690 0.0 12.000 0.828 Vel = 12.78 0.0 567.71 36.974 K Factor= 93.36 217 0.0 1.61 2T 16.0 112.500 36.146 to 120 0.0 16.000 0.0 117 0.0 0.0 0.0 128.500 0.0 Vel =0 0.0 - 0.0 36.146 K Factor =0 217 567.71 4.26 0.0 12.000 36.146 to 120 0.0 0.0 0.0 218 567.71 0.0690 0.0 12.000 0.828 Vel = 12.78 0.0 567.71 36.974 K Factor= 93.36 118 567.71 4.26 0.0 12.000 36.974 to 120 0.0 0.0 0.0 119 567.71 0.0689 0.0 12.000 0.827 Vel= 12.78 0.0 567.71 37.801 KFactor= 92.34 218 0.01 1.61 2T 16.0 112.500 36.974 to 120 0.0 16.000 0.0 118 0.01 0.0 0.0 128.500 0.0 Vel =0 0.0 0.01 36.974 K Factor = 0 218 567.70 4.26 0.0 12.000 36.974 to 120 0.0 0.0 0.0 219 567.7 0.0689 0.0 12.000 0.827 Vel= 12.78 0.0 567.70 37.801 KFactor= 92.34 119 567.77 4.26 0.0 12.000 37.801 to 120 0.0 0.0 0.0 120 567.77 0.0690 0.0 12.000 0.828 Vel = 12.78 0.0 567.77 38.629 K Factor= 91.35 219 0.06 1.61 2T 16.0 112.500 37.801 to 120 0.0 16.000 0.0 119 0.06 0.0 0.0 128.500 0.0 - Vel = 0.01 0.0 0.06 37.801 KFactor= 0.01 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 21 TARGET Warehouse- Carlsbad / K=l 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 219 567.64 4.26 0.0 12.000 37.801 to 120 0.0 0.0 0.0 220 567.64 0.0690 0.0 12.000 0.828 Vel = 12.78 0.0 567.64 38.629 K Factor = 91.33 120 567.96 4.26 0.0 12.000 38.629 to 120 0.0 0.0 0.0 121 567.96 0.0690 0.0 12.000 0.828 Vel= 12.78 0.0 567.96 39.457 K Factor = 90.42 220 0.19 1.61 2T 16.0 112.500 38.629 to 120 0.0 16.000 0.0 120 0.19 0.0 0.0 128.500 0.0 Vel = 0.03 0.0 0.19 38.629 K Factor = 0.03 220 567.45 4.26 0.0 12.000 38.629 to 120 0.0 0.0 0.0 221 567.45 0.0688 0.0 12.000 0.826 Vel = 12.77 0.0 567.45 39.455 K Factor= 90.34 121 568.40 4.26 0.0 12.000 39.457 to 120 0.0 0.0 0.0 122 568.4 0.0691 0.0 12.000 0.829 Vel = 12.79 0.0 568.40 40.286 K Factor = 89.55 221 0.44 1.61 2T 16.0 112.500 39.455 to 120 0.0 16.000 0.0 121 0.44 0.0 0.0 128.500 0.002 Vel = 0.07 0.0 0.44 39.457 K Factor = 0.07 221 567.01 4.26 0.0 12.000 39.455 to 120 0.0 0.0 0.0 222 567.01 0.0688 0.0 12.000 0.826 Vel = 12.76 0.0 567.01 40.281 K Factor = 89.34 122 569.22 4.26 0.0 12.000 40.286 to 120 0.0 0.0 0.0 123 569.22 0.0693 0.0 12.000 0.832 Vel = 12.81 0.0 569.22 41.118 K Factor = 88.77 222 0.81 1.61 2T 16.0 112.500 40.281 to 120 0.0 16.000 0.0 122 0.81 0.0 0.0 128.500 0.005 Vel = 0.13 0.0 0.81 40.286 K Factor = 0.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 22 TARGET Warehouse- Carlsbad / K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 222 566.19 4.26 0.0 12.000 40.281 to 120 0.0 0.0 0.0 223 566.19 0.0686 0.0 12.000 0.823 Vet = 12.74 0.0 566.19 41.104 KFactor 88.31 123 570.54 4.26 0.0 12.000 41.118 to 120 0.0 0.0 0.0 124 570.54 0.0696 0.0 12.000 0.835 Vet = 12.84 0.0 570.54 41.953 KFactor= 88.09 223 1.33 1.61 2T 16.0 112.500 41.104 to 120 0.0 16.000 0.0 123 1.33 0.0001 0.0 128.500 0.014 VeI= 0.21 0.0 1.33 41.118 KFactor= 0.21 223 564.87 4.26 0.0 12.000 41.104 to 120 0.0 0.0 0.0 224 564.87 0.0683 0.0 12.000 0.820 Vet = 12.72 0.0 564.87 41.924 KFactor= 87.24 124 572.53 4.26 0.0 12.000 41.953 to 120 0.0 0.0 0.0 125 572.53 0.0701 0.0 12.000 0.841 Vet = 12.89 0.0 572.53 42.794 KFactor= 87.52 224 1.99 1.61 2T 16.0 112.500 41.924 to 120 0.0 16.000 0.0 124 1.99 0.0002 0.0 128.500 0.029 Vel= 0.31 0.0 - 1.99 41.953 K Factor = 0.31 224 562.88 4.26 0.0 12.000 41.924 to 120 0.0 0.0 0.0 225 562.88 0.0678 0.0 12.000 0.814 Vet = 12.67 0.0 562.88 42.738 KFactor= 86.10 125 575.34 4.26 0.0 12.000 42.794 to 120 0.0 0.0 0.0 126 575.34 0.0707 0.0 12.000 0.848 Vet = 12.95 0.0 575.34 43.642 KFactor= 87.09 225 2.81 1.61 2T 16.0 112.500 42.738 to 120 0.0 16.000 0.0 125 2.81 0.0004 0.0 128.500 0.056 Vet = 0.44 0.0 2.81 42.794 K Factor= 0.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 23 TARGET Warehouse- Carlsbad / K1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 225 560.07 4.26 0.0 12.000 42.738 to 120 0.0 0.0 0.0 226 560.07 0.0673 0.0 12.000 0.808 Vel = 12.61 0.0 560.07 43.546 KFactor= 84.87 126 579.14 4.26 0.0 10.167 43.642 to 120 0.0 0.0 0.0 127 579.14 0.0715 0.0 10.167 0.727 Vel= 13.04 0.0 579.14 44.369 K Factor= 86.94 226 3.80 1.61 2T 16.0 112.500 43.546 to 120 0.0 16.000 0.0 126 3.8 0.0007 0.0 128.500 0.096 Vet = 0.60 0.0 3.80 43.642 K Factor = 0.58 226 556.27 4.26 0.0 10.167 43.546 to 120 0.0 0.0 0.0 227 556.27 0.0664 0.0 10.167 0.675 Vel = 12.52 0.0 556.27 44.221 K Factor= 83.65 127 583.95 4.26 ii 9.217 9.167 44.369 to 120 0.0 9.217 0.0 128 583.95 0.0727 0.0 18.384 1.336 Vet = 13.14 0.0 583.95 45.705 KFactor= 86.38 227 4.81 1.61 2T 16.0 112.500 44.221 to 120 0.0 16.000 0.0 127 4.81 0.0012 0.0 128.500 0.148 Vel = 0.76 0.0 4.81 44.369 KFactor= 0.72 227 551.46 4.26 11 9.217 9.167 44.221 to 120 0.0 9.217 0.0 228 551.46 0.0653 0.0 18.384 1.201 Vet = 12.41 0.0 551.46 45.422 KFactor= 81.82 128 583.95 4.26 IT 26.334 49.833 45.705 to 120 0.0 26.334 0.0 328 583.95 0.0726 0.0 76.167 5.533 Vet = 13.14 0.0 583.95 51.238 K Factor= 81.58 228 551.46 4.26 1 26.334 62.667 45.422 to 120 0.0 26.334 0.0 328 551.46 0.0653 0.0 89.001 5.816 Vel= 12.41 328 583.95 6.357 11 12.573 3.000 51.238 to 120 0.0 12.573 0.0 R-T 1135.41 0.0354 0.0 15.573 0.551 Vet = 11.48 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 24 TARGET Warehouse- Carlsbad / K=1 1.2 Sprinklers Date 9-21-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn R-T 0.0 6.357 lAla 33.948 21.417 51.789 to 120 0.0 33.948 9.276 R-B 1135.41 0.0354 0.0 55.365 1.959 Vel = 11.48 R-B 100.00 6.16 IM 17.215 14.000 63.024 Qa = 100 to 140 0.0 17.215 1.732 Ui 1235.41 0.0363 0.0 31.215 1.132 Vel= 13.30 UI 0.0 6.09 2F 21.583 60.000 65.888 to 150 IM 18.5 90.957 6.280 U2 1235.41 0.0337 IG 4.625 150.957 5.093 Vel = 13.61 iT 46.249 U2 0.0 7.98 1M 24.162 197.000 77.261 to 150 0.0 24.162 1.299 BF1 1235.41 0.0090 0.0 221.162 2.001 Vel= 7.92 BF1 0.0 8.27 0.0 8.000 80.561 to 140 0.0 0.0 8.000 * Fixed loss = 8 BF2 1235.41 0.0086 0.0 8.000 0.069 Vel = 7.38 BF2 400.00 7.98 2M 48.325 4.000 88.630 Qa = 400 to 150 0.0 48.325 0.0 U3 1635.41 0.0152 0.0 52.325 0.796 Vel = 10.49 U3 0.0 7.98 1M 24.162 46.500 89.426 to 150 iT 52.855 83.057 0.0 SOR 1635.41 0.0152 1G 6.041 129.557 1.969 Vel = 10.49 0.0 1635.41 91.395 K Factor = 171.07 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SPEECJFICATION SUBM1TTfl\L SHEET 4=4 ov STANDARDS COMPLIANCE FEATURES (Unless otherwise noted, applies to sizes 4" thru 10") Sizes: El 4" D 6' '8" Q 10' • ASSE® Listed 1048 APPLICATION Designed for installation on potable water lines in fire sprinkler systems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWVIIA C606 (Flanged) ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) - with Os & Y gate valves (standard) 1 L - less shut-off valves (grooved body connections) C3 LM - less water meter El - with remote reading meter - with gpm meter (standard) - with cu ft/min meter El G - with groove end gate valves O FG - with flanged inlet gate connection and grooved outlet gate connection O FS - with cast iron wye type strainer (flanged only) 0 FSC - with epoxy coated wye type strainer (flanged only) OBGVIC - with grooved end butterfly valves C3 P1 - with Post Indicator Gate Valve (3°-1 0) ACCESSORIES 0 Repair kit (rubber only) 0 Thermal expansion tank (Model WXTP) 0 Valve setter (Model FLS or MJS or MJFS) 0 Gate valve tamper switch (OSY-40) 0 Flange by groove adapter (FLA) 0 QT-SET Quick Test Fitting Set 0 Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) CSA® Certified (4" & 6') AWWA Compliant C 510 UL® Classified C-UL® Classified FM® Approved NYC MEA26-00-M VOL 3 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California MATERIALS Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYL, NSF Listed Springs Stainless steel, 300 series DIMENSIONS (approximate) WEIGHT MODEL ___________ 40 B B C C LESS OS&Y SIZE A WITH GATE LESS GATE OS&Y OS&Y D GATE GATE VALVES VALVES OPEN CLOSED VALVES VALVES in. mm in. mm in. mm in. mm in. I mm in. mm in. mm HDS. I•g 4 100 185/16 465 30 762 21 533 223/4 578 181/4 460 8 203 105 47.7 295 134 6 150 1811/16 475 351/2 902 25 635 1301/81 765 233/4 603 10 254 174 79 474 215 8 200 29 737 46 1168 1347/16. 845 1373/41 959 1291/4 743 13 330 402 182.5 878 399 10 250 29 737 471/2 1207 34 7/16 845 45 3/4 1162 35 3/8 899 13 330 420 191 1076 I 489 • 1 331) E Page 1 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238.7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11 2 Phone: 905/405-8272 Fax:9051405.1292 Product Support Help Line: 1-877-BACKFLOW (1.877-222-5356) Website: http://www.zurn.com WILKINS SETTER OUTDOOR INSTALLATION FLOW CHARACTERISTICS MODEL 45004" & 6" (STANDARD & METRIC) FLOW RATES (us) 0.0 25.2 50.5 75.7 100.9 U, 0. 15 (100mm) 103 0. CI, tj) 10 0 400 800 1200 1600 FLOW RATES (GPM) MODEL 4500A 8" & 10" (STANDARD & METRIC) FLOW RATES (us) 0.0 63.1 126.2 189.3 252.4 103 i' CI. U, a. U,1 U, UJI LU IL 1000 2000 3000 Rated Flow (Established by approval agencies) EROTECTIVE - - - - TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 SPECIFICATIONS The Double Check Detector Backflow Preventer shall be ASSE® Listed 1048 and supplied with full port OS & Y gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYL TM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks shall be accessible for maintenance without removing the device from the line. The Double Check Detector 6ackflow Preventer shall be a WILKINS Model 450DA. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238.5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11-2 Phone:9051405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zurn.com Page 2 of 2 MODEL SIZE in. I mm DIMENSIONS (approximate) Al SETTER END TO END FLS in. I mm Al SETTER END TOEND MJS in. I mm 4 I 100 315/161 795 29.3131745 6 I 150 1 343/4 I 884 32.75 832 8 I 200 1 47 11194 44.625t1133 10 I 250 1 51 I 1295 47 Iiii Fire Protection by Computer Design COSCO Fire Protection, Inc. 321 East Gardena Blvd. Gardena, CA. 90247 (323) 321-5155 .55 s #4,e Mos4.au%a44 4 Spr.s Job Name : TARGET Warehouse- Carlsbad Drawing : Off-Site Warehouse Location 6231 '(arrow Drive, Suite C, Carlsbad, CA. Remote Area : WEST-side Contract : #1 5GS-0463 Data File TARGET Whse_K11-2K_4Remote.wxf Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 COSCO Fire Protection, Inc. Page 1 TARGET Warehouse- Carlsbad Date 8-20-09 Hydraulic Design Information Sheet Name - TARGET Warehouse T1029 - Carlsbad (4 Most Remote) Date - 9-21-09 Location - 6231 Yarrow Drive, Suite C, Carlsbad, CA. Building - Off-Site Warehouse System No. - WEST-side Contractor - COSCO FIRE PROTECTION, INC. Contract No. - #15GS-0463 Calculated By - Mike Coughlin Drawing No. - FP-1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 251 -0" Occupancy - STORAGE WAREHOUSE wl Racks & Shelves S (X) NFPA 13 C ) Lt. Haz. Ord.Haz.Gp. ( ) 1 C ) 2 C ) 3 (X) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling 0.55 GPM / 400 sq.ft. Made By TELGIAN Date 8-6-09 E M Area of Sprinkler Operation - 400 System Type Sprinkler/Nozzle Density - 0.55 (X) Wet Make Reliable D Area Per Sprinkler - 100 max. C ) Dry Model "G-XLO" E Elevation at Highest Outlet - 24.042' C ) Deluge Size 3/41" S Hose Allowance - Inside - 100 ( ) Preaction K-Factor 11.2 I Rack Sprinkler Allowance - N.A. ( ) Other Temp.Rat.= 165 G Hose Allowance - Outside - 400 N Note : Most Remote 4 Sprinklers, only. Calculation Flow Required - 720.147 Press Required - 62.31 Summary C-Factor Used: 120 Overhead 140 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 4-15-08 Cap. - T Time of Test - N.A. Rated Cap.- Elev.- E Static Press - 124 @ Press - R Residual Press - 118 Elev. - Well Flow - 1060 Proof Flow S Elevation - -18.0' U P Location - 6231 Yarrow Dr., Carlsbad Fire Dept. P NOTE: Hydr. Calc.s input = Reduced by 10% L Source of Information - Hydr. Calc.s by West Coast Fire Prot. (3-2-09) Y per Brenda @ Carlsbad Fire Dept. (8-25-09) C Commodity Retail Products Storage Class I-IV w/ Location 0 Storage Ht. 15 1 -011' Area 8' Aisle W. M Storage Method: Solid Piled % Palletized 80 % Rack M SR TA O C R K A G E Single Row (X) Conven. Pallet ( ) Auto. Storage (X) Encap. (X) Double Row ( ) Slave Pallet ( ) Solid Shelf C ) Non Mult. Row (X) Open Shelf Flue Spacing 0-8" Clearance:Storage to Ceiling 81 -0" Longitudinal Transverse Horizontal Barriers Provided: >> See attached TARGET plan: F911 Water Supply Curve (C) COSCO Fire Protection, Inc. Page 2 TARGET Warehouse- Carlsbad Date 8-20-09 City Water Supply: Cl - Static P'ressure : 111.6 ) C2- Residual Pressure: 105.6 ''- Wo+sr F(o Cu r ye. p (o 4JcL Demand: Dl - Elevation D2 - System Flow : 19.508 : 220.147 C2 - Residual Flow : 1060 LLyf 021 D2 - System Pressure Hose(Adj City) : 62.305 Hose ( Demand) : 500 D3 - System Demand : 720.147 Safety Margin : 46.360 150 140 130 P 120 Cl R 110 E 100 S90 S80 U 70 R 60 E 50 40 30 20 Dl 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N A 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary COSCO Fire Protection, Inc. Page 3 TARGET Warehouse- Carlsbad Date 8-20-09 Fitting Legend Abbrev. Name % % 1 1% 1/2 2 2% 3 31,4 4 5 6 8 10 12 14 16 18 20 24 Ala Generic Alarm Valve 0 0 0 0 0 0 7.7 21.5 0 17 17 27 29 0 0 0 0 0 0 0 F 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90' Ell Grvd-Vic#10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 M Medium Turn Elbow 0 2 2 3 3 4 5 6 6 8 10 12 16 19 22 0 0 0 0 0 T 90' Flow lhruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A i.J'Jiitui I I flV.'..A w C CD NO to CD Ae bld E; Large %rIfice Extra Large Orifice Sprinkler (SIN R2921) Features The Reliable Model G XLO sprinkler offers the opportunity for: 1. Pipe size reduction 2. Fewer sprinklers _3aiminationofsterpumps_ -- 4. Increasing densities with existing systems 5.3/2 NPT (R½) available for retrofit installations only. 6. Aso includes additional Specific Application listing. (See detailed "UL Specification Application listing" described on the back page.) Listings & Approvals: Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories' of Canada (ULC) Approved by Factory Mutual (FM) I 4. NYC MEA 258-93-E (NFPA 13*). UL Guide Number VNIV UL Listing Category Sprinklers, Automatic & Open Extra Large Orifice Upright Sprinkler and Specific Application Sprinkler. Technical Data Sprinkler Nominal - K Factor Sprinkler Sprinkler Type US Metric Height ApprovaLs Identification Numr (SIN) Upright 0.64 Orifice with 11.2 160 14 3. (80mm) 1,2,3,4 R2921 ¼ NF(Rt4) Upright Retrofit 3.25 0.64 Orifice with 11.2 160 1,2,3,4 [ R2921 1/2 NPT Rh () Note: This product has been tested and listed for storage appli- cations to qualify its use in lieu of 5.6K or 8.0K Factor sprinklers for the protection of high-piled storage. Product Description The Reliable Model G XLO sprinkler is a center strut solder in compression extra large orifice upright sprinkler that has been designed to control high chal- lenge fires in both palletized and rack storage occu- pancies utilizing relatively low water pressures. This sprinkler is available with either the standard 3% NPT (R 34) threads for new installations or with X NPT (R½) threads for retrofit applications. It has been proven in full-scale fire testing, has com- plied with the applicable mechanical and hydraulic sections of the latest sprinkler standards and has Fac- tory Mutual Approval and Underwriters Laboratories and Underwriters Laboratories' of Canada Listings. This product is intended for use as a standard spray sprinkler in hydraulically designed systems with a minimum pressure of 7 psi (0.5 bar) in accor- dance with the area/density curves of NFPA 13* stan- dards and for all area/density methods of design as referenced by Factory Mutual (FM) Prevention Data Sheets. Design Criteria The folloMng criteria apply when designing an automatic spin- kier system utilizing the Model G XLO sprinkler for NFPA 13* applications. Sprinkler spacing shall be a minimum of 6 ft (1.8m) Sprinklers with Y2 NFl (R½) are to be used for retrofit applications only. Sprinkler discharge pressure per NFPA 13* standards shall be a minimum of 7 psi (0,5 bar). Sprinkler discharge pressure for NFPA 13* standard and all Factory Mutual (FM) applications shall be a minimum of 10 psi (0.7 bar). Factory Mutual (FM) Loss Prevention Data Sheets contain requirements which differ from NFPA The Model G XLO is Approved by Factory Mutual for all area/density methods of design as referenced by FM Loss Prevention Data Sheets. The Model G XLO Extra Large Orifice sprinkler is intended for standard flow/pressure requirements and standard place- ment as specified for NFPA storage requirements. The Model G XLO sprinkler is not a "Large Drop" or "ESFR" sprinkler. Temperature Ratings Sprinkler Maximum Ambient Classification Rating Temperature Frame Color OC F C ¶ Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White High 286 141 1 225 107 Blue * For sprinkler standards prior to 1999 edition of NFPA 13, use NFPA standards 231, 231C, 231D & 231F. The Reliable Automatic Sprinkler Co., Inc. • 525 North MacQuesten Parkway Mount Vemon • New York 10552 Finishes Standard Finishes Bronze Chrome Special Application Finishes Lead Plated -165 F(74 C), 212 F(100C)and 286 F(141 C) Temp. Ratings Wax a -165 F(74 C) Clear Wax, 212 F (100 C)Brown Wax Wa,qtead '" - 165 F (74 C) Clear wax, 212 F(100 C)Brown Wax UL Listed only. (2) 212 F (100 C) Brown wax may be used on 286 F (141 C) Sprinklers when maximum ambient temperatures do not exceed 150 F (66 C). Maintenance Model G XLO Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in anyway. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non-operation. Ordering Information Specify: The UL Specific Application Listing is: 1. Sprinkler Model The Model G XLO uptht sp~nlqer is intandadjQr use in _-2. Temperature Rating 7:7- - .- -- accordance with the standard sprinkler positioning and area/density flow calculation requirements as specified in each respective standard. Model G XLO upright sprinklers may also be installed to protect single, double and multiple - Model H Sprinkler Wrench row and portable rack storage of Class WV, Groups A and B plastics, cartoned, expanded or unexpanded, as well as exposed unexpanded with a maximum storage height of20ft. (6.5m), maximum ceiling height of 25 ft (8.2m) or27ft (8.8m) maximum ceiling height, 36 (914mm) minimum deflector to top of storage clearance, design density of 0.60 gpm/ ff. (24.7 Lknir*n2), and a design area Of 2000 ft2. (186m) for wet systems and 2600 ff. (242rn) for dry systems. Note: Maximum 27ft ceilling height is allowed by NFPA 13*, Mthout in-rack sprinklers in a protected area, provided the ceiling sprinklers' discharge is increased to 0.6 gprrVft2 in a 2000 ft2 design area. Installation Reliable's Model G XLO sprinkler must be installed according to NFPA Standards or the appropriate Factory Mutual Loss Prevention Data Sheets for all area/density methods of design as well as the Authority Having Jurisdiction. The Model GXLO sprinkler meets the NFPA 13* code stan-dards for approval by Factory Mutual and listings by Under- writers Laboratories & Underwriters Laboratories of Canada (v NPT) 2.82'S [77.6mm] (1/4" NPT) Zil" lea.emm] JI J. 14" (Y/4 RASCO f79.&nmj I f47,5mrr,J I29tOJ7 hPT) NPT) * For sprinkler standards prior to 1999 edition of NFPA 13, use NFPA standards 231, 231C, 231D & 231F. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States. Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices w.reIiablesprinkter.con'i Internet Address Revision lines indicate updated or new data. PG. Printed in U.S.A. 06/02 Pfl'19999970022 Use onty the Model H sprinkler wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Pressure / Flow Summary - STANDARD COSCO Fire Protection, Inc. Page 4 TARGET Warehouse- Carlsbad Date 8-20-09 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 101 21.917 33.03 na W1L 21.917 33.03 na Wi 24.042 32.11 na WK 21.917 33.03 na W2 24.042 32.1 na W3L 21.917 33.03 na W3 24.042 32.1 na W41- 21.917 33.02 na W4 24.042 32.1 na W51- 21.917 33.02 na W5 24.042 32.1 na W61- 21.917 33.02 na W6 24.042 32.1 na W71- 21.917 33.02 na W7 24.042 32.1 na 201 21.917 33.02 na 102 21.917 33.03 na W8L 21.917 33.03 na W8 24.042 32.11 na W91- 21.917 33.03 na W9 24.042 32.11 na W1OL 21.917 33.03 na W10 24.042 32.1 na WilL 21.917 33.02 na Wit 24.042 32.1 na W12L 21.917 33.02 na W12 24.042 32.1 na W13L 21.917 33.02 na W13 24.042 32.1 na W14L 21.917 33.02 na W14 24.042 32.1 na 202 21.917 33.02 na 103 21.917 33.03 na W15L 21.917 31.43 na W15 24.042 30.51 na W16L 21.917 31.19 na W16 24.042 30.27 na W17L 21.917 30.94 na W17 24.042 11.2 24.16 na 55.05 0.55 100 24.115 W18L 21.917 30.88 na W18 24.042 11.2 24.12 na 55.0 0.55 100 24.115 W19L 21.917 30.89 na Wig 24.042 11.2 24.12 na 55.0 0.55 100 24.115 W20L 21.917 30.98 na W20 24.042 11.2 24.19 na 55.09 0.55 100 24.115 W21 21.917 31.29 na W21 24.042 30.37 na 203 21.917 33.02 na 104 21.917 33.07 na W22L 21.917 33.06 na W22 24.042 32.14 na W23L 21.917 33.06 na W23 24.042 32.14 na W24L 21.917 33.06 na W24 24.042 32.14 na W25L 21.917 33.06 na W25 24.042 32.14 na W26L 21.917 33.06 na W26 24.042 32.14 na W27L 21.917 33.06 na W27 24.042 32.14 na W28L 21.917 33.06 na W28 24.042 32.14 na 204 21.917 33.06 na 105 21.917 33.1 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard COSCO Fire Protection, Inc. TARGET Warehouse- Carlsbad Node Elevation K-Fact Pt Pn Flow No. Actual Actual Page 5 Date 8-20-09 Density Area Press W29L 21.917 33.1 na W29 24.042 32.18 na W30L 21.917 33.1 na W30 24.042 32.18 na W31 21.917 33.1 na W31 24.042 32.18 na W32L 21.917 33.1 na W32 24.042 32.18 na W33L 21.917 33.1 na W33 24.042 32.18 na W34L 21.917 33.1 na W34 24.042 32.18 na W35L 21.917 33.1 na W35 24.042 32.18 na 205 21.917 33.1 na 106 21.917 33.14 na 206 21.917 33.14 na 107 21.917 33.18 na 207 21.917 33.18 na 108 21.917 33.22 na 208 21.917 33.22 na 109 21.917 33.26 na 209 21.917 33.26 na 110 21.917 33.3 na 210 21.917 33.3 na 111 21.917 33.34 na 211 21.917 33.34 na 112 21.917 33.38 na 212 21.917 33.38 na 113 21.917 33.42 na 213 21.917 33.42 na 114 21.917 33.46 na 214 21.917 33.46 na 115 21.917 33.5 na 215 21.917 33.5 na 116 21.917 33.54 na 216 21.917 33.54 na 117 21.917 33.58 na 217 21.917 33.58 na 118 21.917 33.62 na 218 21.917 33.62 na 119 21.917 33.66 na 219 21.917 33.66 na 120 21.917 33.7 na 220 21.917 33.7 na 121 21.917 33.74 na 221 21.917 33.74 na 122 21.917 33.78 na 222 21.917 33.78 na 123 21.917 33.82 na 223 21.917 33.82 na 124 21.917 33.86 na 224 21.917 33.86 na 125 21.917 33.9 na 225 21.917 33.9 na 126 21.917 33.94 na 226 21.917 33.94 na 127 21.917 33.98 na 227 21.917 33.97 na 128 21.917 34.04 na 228 21.917 34.03 na 328 21.917 34.31 na R-T 21.917 34.34 na R-B 0.5 43.71 na 100.0 U -3.5 45.53 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard COSCO Fire Protection, Inc. TARGET Warehouse- Carlsbad Node Elevation K-Fact Pt Pn Flow Density No. Actual Actual Page 6 Date 8-20-09 Area Press U2 -18.0 52.23 na BF1 -21.0 53.69 na BF2 -21.0 61.7 na 400.0 U3 -21.0 61.87 na SOR -21.0 62.31 na The maximum velocity is 20.45 and it occurs in the pipe between nodes W20 and W20L Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 7 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 101 2.53 4.26 0.0 8.417 33.027 to 120 0.0 0.0 0.0 102 2.53 0.0 0.0 8.417 0.0 Vel = 0.06 0.0 2.53 33.027 K Factor = 0.44 W1L 2.53 2.635 IT 16.474 36.250 33.026 to 120 0.0 16.474 0.0 101 2.53 0.0 0.0 52.724 0.001 VeI= 0.15 0.0 2.53 33.027 K Factor = 0.44 Wi 0.0 1.049 iT 5.0 1.917 32.105 to 120 0.0 5.000 0.920 W1L 0.0 0.0001 0.0 6.917 0.001 Vel0 0.0 0.0 33.026 K Factor =0 W2L 2.53 2.635 0.0 8.000 33.025 to 120 0.0 0.0 0.0 W1L 2.53 0.0001 0.0 8.000 0.001 Vel = 0.15 0.0 2.53 33.026 K Factor = 0.44 W2 0.0 1.049 iT 5.0 1.917 32.105 to 120 0.0 5.000 0.920 W2L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.025 K Factor = 0 WK 2.53 2.635 0.0 8.000 33.025 to 120 0.0 0.0 0.0 W2L 2.53 0.0 0.0 8.000 0.0 Vel = 0.15 0.0 2.53 33.025 K Factor = 0.44 W3 0.0 1.049 iT 5.0 1.917 32.105 to 120 0.0 5.000 0.920 WK 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.025 K Factor =0 W4L 2.53 2.635 0.0 8.000 33.025 to 120 0.0 0.0 0.0 WK 2.53 0.0 0.0 8.000 0.0 Vel = 0.15 0.0 2.53 33.025 K Factor = 0.44 W4 0.0 1.049 IT 5.0 1.917 32.104 to 120 0.0 5.000 0.920 W4L 0.0 0.0001 00 6.917 0.001 Vel = 0 0.0 0.0 33.025 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 8 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W5L 2.53 2.635 0.0 8.000 33.025 to 120 0.0 0.0 0.0 W4L 2.53 0.0 0.0 8.000 0.0 Vel = 0.1,5 0.0 2.53 33.025 K Factor = 0.44 W5 0.0 1.049 IT 5.0 1.917 32.104 to 120 0.0 5.000 0.920 W5L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 33.025 K Factor = 0 W6L 2.53 2.635 0.0 -8.000 33.024 to 120 0.0 0.0 0.0 W5L 2.53 0.0001 0.0 - 8.000 0.001 Vel = 0.15 0.0 2.53 33.025 KFactor= 0.44 W6 0.0 1.049 IT 5.0 1.917 32.104 to 120 0.0 5.000 0.920 W6L 0.0 0.0 0.0 6.917 0.0 Vel = Or 0.0 0.0 33.024 K Factor = 0 W7L 2.53 2.635 0.0 8.000 33.024 to 120 0.0 0.0 0.0 W6L 2.53 0.0 0.0 8.000 0.0 Vel = 0.15 0.0 2.53 33.024 K Factor= 0.44 W7 0.0 1.049 IT 5.0 1.917 32.104 to 120 0.0 5.000 0.920 W7L 0.0 0.0 '0.0 6.917 0.0 Vel = 0 0.0 0.0 33.024 K Factor = 0 201 2.53 2.635 1 16.474 28.250 33.023 to 120 0.0 16.474 0.0 W7L 2.53 0.0 0.0 44.724 0.001 Vel = 0.15 0.0 2.53 33.024 ' K Factor= 0.44 201 -2.53 4.26 0.0 8.417 33.023 to 120 0.0 0.0 0.0 202 -2.53 0.0 0.0 8.417 0.0 Vel = 0.06 0.0 --2.53 33.023 - K Factor= -0.44 102 4.82 4.26 0.0 10.875 33.027 to 120 0.0 0.0 0.0 103 4.82 0.0 0.0 10.875 0.0 ' Vel = 0.11 0.0 4.82 33.027 KFactor= 0.84 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 9 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W8L 2.29 2.635 iT 16.474 36.250 33.026 to 120 0.0 16.474 0.0 102 2.29 0.0 0.0 52.724 0.001 Vel = 0.13 0.0 2.29 33.027 K Factor = 0.40 W8 0.0 1.049 IT 5.0 1.917 32.106 to 120 0.0 5.000 0.920 W8L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.026 K Factor = 0 W9L 2.29 2.635 0.0 13.333 33.026 to 120 0.0 0.0 0.0 W8L 2.29 00 0.0 13.333 0.0 Vel = 0.13 0.0 2.29 33.026 K Factor = 0.40 W9 0.0 1.049 11 5.0 1.917 32.105 to 120 0.0 5.000 0.920 W9L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 33.026 K Factor = 0 W1OL 2.29 2.635 0.0 13.333 33.025 to 120 0.0 0.0 0.0 W9L 2.29 0.0001 0.0 13.333 0.001 Vel = 0.13 0.0 2.29 33.026 K Factor = 0.40 W10 0.0 1.049 iT 5.0 1.917 32.105 to 120 0.0 5.000 0.920 WIOL 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.025 K Factor = 0 WilL 2.29 2.635 0.0 13.333 33.025 to 120 0.0 0.0 0.0 WIOL 2.29 0.0 0.0 13.333 0.0 Vel = 0.13 0.0 2.29 33.025 K Factor = 0.40 will 0.0 1.049 iT 5.0 1.917 32.104 to 120 0.0 5.000 0.920 WilL 0.0 0.0001 0.0 6.917 0.001 VeI0 0.0 0.0 33.025 K Factor = 0 W12L 2.29 2.635 0.0 13.333 33.024 to 120 0.0 0.0 0.0 WilL 2.29 0.0001 0.0 13.333 0.001 Vel = 0.13 0.0 2.29 33.025 K Factor = 0.40 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 10 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W12 0.0 1.049 IT 5.0 1.917 32.104 to 120 0.0 5.000 0.920 W1 2L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.024 K Factor 0 W1 3L 2.29 2.635 0.0 13.333 33.024 to 120 0.0 0.0 0.0 W12L 2.29 0.0 0.0 13.333 0.0 Vel = 0.13 0.0 2.29 33.024 K Factor= 0.40 W13 0.0 1.049 IT 5.0 1.917 32.104 to 120 0.0 5.000 0.920 W1 3L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.024 K Factor = 0 W14L 2.29 2.635 0.0 13.333 33.024 to 120 0.0 0.0 0.0 W1 3L 2.29 0.0 0.0 13.333 0.0 Vel = 0.13 0.0 2.29 33.024 K Factor= 0.40 W14 0.0 1.049 IT 5.0 1.917 32.103 to 120 0.0 5.000 0.920 W14L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 33.024 K Factor =0 202 2.29 2.635 IT 16.474 28.250 33.023 to 120 0.0 16.474 0.0 W14L 2.29 0.0 0.0 44.724 0.001 Vel = 0.13 0.0 2.29 33.024 K Factor = 0.40 202 -4.82 4.26 0.0 10.875 33.023 to 120 0.0 0.0 0.0 203 -4.82 -0.0001 0.0 10.875 -0.001 Vel= 0.11 0.0 -4.82 33.022 KFactor= -0.84 103 107.65 4.26 0.0 12.000 33.027 to 120 0.0 0.0 0.0 104 107.65 0.0032 0.0 12.000 0.039 Vel = 2.42 0.0 107.65 33.066 K Factor = 18.72 W1 5L 102.83 2.635 1 16.474 36.250 31.428 to 120 0.0 16.474 0.0 103 102.83 0.0303 0.0 52.724 1.599 Vel = 6.05 0.0 102.83 33.027 KFactor= 17.89 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 11 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. loci. or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W15 0.0 1.049 iT 5.0 1.917 30.508 to 120 0.0 5.000 0.920 W1 5L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 31.428 K Factor =0 W16L 102.83 2.635 0.0 8.000 31.186 to 120 0.0 0.0 0.0 W1 5L 102.83 0.0302 0.0 8.000 0.242 Vel = 6.05 0.0 102.83 31.428 KFactor= 18.34 W16 0.0 1.049 1 5.0 1.917 30.265 to 120 0.0 5.000 0.920 W16L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 31.186 K Factor =0 W1 7L 102.83 2.635 0.0 8.000 30.943 to 120 0.0 0.0 0.0 W16L 102.83 0.0304 0.0 8.000 0.243 Vel = 6.05 0.0 102.83 31.186 KFactor= 18.41 W17 55.05 1.049 iT 5.0 1.917 24.163 K Factor = 11.20 to 120 0.0 5.000 0.920 W17L 55.05 0.8472 0.0 6.917 5.860 Vel = 20.44 0.0 55.05 30.943 K Factor = 9.90 W1 8L 47.78 2.635 0.0 8.000 30.884 to 120 0.0 0.0 0.0 W1 7L 47.78 0.0074 0.0 8.000 0.059 Vet = 2.81 0.0 47.78 30.943 K Factor = 8.59 W18 55.00 1.049 IT 5.0 1.917 24.115 K Factor= 11.20 to 120 0.0 5.000 0.920 W18L 55.0 0.8456 0.0 6.917 5.849 Vel = 20.42 0.0 55.00 30.884 K Factor= 9.90 W1 9L -7.22 2.635 0.0 8.000 30.886 to 120 0.0 0.0 0.0 W1 8L -7.22 -0.0002 0.0 8.000 -0.002 Vel = 0.42 0.0 -7.22 30.884 K Factor = -1.30 W19 55.00 1.049 1 5.0 1.917 24.117 K Factor= 11.20 to 120 0.0 5.000 0.920 W19L 55.0 0.8456 0.0 6.917 5.849 Vel = 20.42 0.0 55.00 30.886 K Factor = 9.90 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 12 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'tC" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W20L -62.23 2.635 0.0 8.000 30.982 to 120 0.0 0.0 0.0 W1 9L -62.23 -0.0120 0.0 8.000 -0.096 Vel = 3.66 0.0 -62.23 30.886 K Factor = -11.20 W20 55.09 1.049 IT 5.0 1.917 24.195 KFactor= 11.20 to 120 0.0 5.000 0.920 W20L 55.09 0.8482 0.0 6.917 5.867 Vel = 20.45 0.0 55.09 30.982 K Factor = 9.90 W21 -117.32 2.635 0.0 8.000 31.292 to 120 0.0 0.0 0.0 W20L -117.32 -0.0388 0.0 8.000 -0.310 Vel = 6.90 0.0 -117.32 30.982 K Factor = -21.08 W21 0.0 1.049 1 5.0 1.917 30.371 to 120 0.0 5.000 0.920 W21 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 31.292 K Factor = 0 203 -117.32 2.635 1 16.474 28.250 33.022 to 120 0.0 16.474 0.0 W21 -117.32 -0.0387 0.0 44.724 -1.730 Vel = 6.90 0.0 -117.32 31.292 K Factor = -20.97 203 112.50 4.26 0.0 12.000 33.022 to 120 0.0 0.0 0.0 204 112.5 0.0035 0.0 12.000 0.042 Vel = 2.53 0.0 112.50 33.064 KFactor= 19.56 104 109.12 4.26 0.0 12.000 33.066 to 120 0.0 0.0 0.0 105 109.12 0.0032 0.0 12.000 0.039 Vel = 2.46 0.0 109.12 33.105 K Factor = 18.97 W22L 1.47 2.635 1 16.474 36.250 33.065 to 120 0.0 16.474 0.0 104 1.47 0.0 0.0 52.724 0.001 Vel = 0.09 0.0 1.47 33.066 K Factor = 0.26 W22 0.0 1.049 IT 5.0 1.917 32.145 to 120 0.0 5.000 0.920 W22L 0.0 0.0 0.0 6.917 0.0 Vet = 0 0.0 0.0 33.065 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 13 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W23L 1.47 2.635 0.0 8.000 33.065 to 120 0.0 0.0 0.0 W22L 1.47 0.0 0.0 8.000 0.0 Vel = 0.09 0.0 1.47 33.065 K Factor = 0.26 W23 0.0 1.049 iT 5.0 1.917 32.145 to 120 0.0 5.000 0.920 W23L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.065 K Factor =0 W24L 1.47 2.635 0.0 8.000 33.065 to 120 0.0 0.0 0.0 W23L 1.47 0.0 0.0 8.000 0.0 Vel = 0.09 0.0 1.47 33.065 K Factor = 0.26 W24 0.0 1.049 IT 5.0 1.917 32.144 to 120 0.0 5.000 0.920 W24L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 33.065 K Factor = 0 W25L 1.47 2.635 0.0 8.000 33.065 to 120 0.0 0.0 0.0 W24L 1.47 0.0 0.0 8.000 0.0 Vel = 0.09 0.0 1.47 33.065 K Factor = 0.26 W25 0.0 1.049 iT 5.0 1.917 32.144 to 120 0.0 5.000 0.920 W25L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 33.065 K Factor = 0 W26L 1.47 2.635 0.0 8.000 33.065 to 120 0.0 0.0 0.0 W25L 1.47 0.0 0.0 8.000 0.0 Vel = 0.09 0.0 1.47 33.065 K Factor = 0.26 W26 0.0 1.049 iT 5.0 1.917 32.144 to 120 0.0 5.000 0.920 W26L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 33.065 K Factor =0 W27L 1.47 2.635 0.0 8.000 33.064 to 120 0.0 0.0 0.0 W26L 1.47 0.0001 0.0 8.000 0.001 Vel = 0.09 0.0 1.47 33.065 K Factor = 0.26 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 14 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W27 0.0 1.049 IT 5.0 1.917 32.144 to 120 0.0 5.000 0.920 W27L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.064 K Factor = 0 W28L 1.47 2.635 0.0 8.000 33.064 to 120 0.0 0.0 0.0 W27L 1.47 0.0 0.0 8.000 0.0 Vet = 0.09 0.0 1.47 33.064 K Factor = 0.26 W28 0.0 1.049 iT 5.0 1.917 32.144 to 120 0.0 5.000 0.920 W28L 0.0 0.0 0.0 6.917 0.0 Vet = 0 0.0 0.0 33.064 K Factor =0 204 1.47 2.635 1 16.474 28.250 33.064 to 120 0.0 16.474 0.0 W28L 1.47 0.0 0.0 44.724 0.0 Vet = 0.09 0.0 1.47 33.064 K Factor = 0.26 204 111.03 4.26 0.0 12.000 33.064 to 120 0.0 0.0 0.0 205 111.03 0.0033 0.0 12.000 0.040 Vel= 2.50 0.0 111.03 33.104 KFactor= 19.30 105 109.80 4.26 0.0 12.000 33.105 to 120 0.0 0.0 0.0 106 109.8 0.0032 0.0 12.000 0.039 Vet = 2.47 0.0 109.80 33.144 KFactor= 19.07 W29L 0.69 2.635 IT 16.474 36.250 33.105 to 120 0.0 16.474 0.0 105 0.69 0.0 0.0 52.724 0.0 Vel = 0.04 0.0 0.69 33.105 KFactor= 0.12 W29 0.0 1.049 iT 5.0 1.917 32.184 to 120 0.0 5.000 0.920 W29L 0.0 0.0001 0.0 6.917 0.001 Vet = 0 0.0 0.0 33.105 K Factor= 0 W30L 0.69 2.635 0.0 8.000 33.105 to 120 0.0 0.0 0.0 W29L 0.69 0.0 0.0 8.000 0.0 Vel = 0.04 0.0 0.69 33.105 KFactor= 0.12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 15 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W30 0.0 1.049 IT 5.0 1.917 32.184 to 120 0.0 5.000 0.920 W30L 0.0 0.0001 0.0 6.917 0.001 Vel =0 0.0 0.0 33.105 K Factor = 0 W31 0.69 2.635 0.0 8.000 33.105 to 120 0.0 0.0 0.0 W30L 0.69 0.0 0.0 8.000 0.0 Vet = 0.04 0.0 0.69 33.105 K Factor= 0.12 W31 0.0 1.049 IT 5.0 1.917 32.184 to 120 0.0 5.000 0.920 W31 0.0 0.0001 0.0 6.917 0.001 Vel =0 0.0 0.0 33.105 K Factor =0 W32L 0.69 2.635 0.0 8.000 33.104 to 120 0.0 0.0 0.0 W31 L 0.69 0.0001 0.0 8.000 0.001 Vel = 0.04 0.0 0.69 33.105 KFactor= 0.12 W32 0.0 1.049 11 5.0 1.917 32.184 to 120 0.0 5.000 0.920 W32L 0.0 0.0 0.0 6.917 0.0 Vel =0 0.0 0.0 33.104 K Factor =0 W33L 0.69 2.635 0.0 8.000 33.104 to 120 0.0 0.0 0.0 W32L 0.69 0.0 0.0 8.000 0.0 Vet = 0.04 0.0 0.69 33.104 K Factor= 0.12 W33 0.0 1.049 IT 5.0 1.917 32.184 to 120 0.0 5.000 0.920 W33L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.104 K Factor =0 W34L 0.69 2.635 0.0 8.000 33.104 to 120 0.0 0.0 0.0 W33L 0.69 0.0 0.0 8.000 0.0 Vet = 0.04 0.0 0.69 33.104 K Factor = 0.12 W34 0.0 1.049 IT 5.0 1.917 32.184 to 120 0.0 5.000 0.920 W34L 0.0 0.0 0.0 6.917 0.0 Vet = 0 0.0 0.0 33.104 K Factor =0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 16 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W35L 0.69 2.635 0.0 8.000 33.104 to 120 0.0 0.0 0.0 W34L 0.69 0.0 0.0 8.000 0.0 Vel = 0.04 0.0 0.69 33.104 KFactor= 0.12 W35 0.0 1.049 iT 5.0 1.917 32.184 to 120 0.0 5.000 0.920 W35L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 33.104 K Factor =0 205 0.69 2.635 1 16.474 28.250 33.104 to 120 0.0 16.474 0.0 W35L 0.69 0.0 0.0 44.724 0.0 Vel = 0.04 0.0 0.69 33.104 KFactor= 0.12 205 110.34 4.26 0.0 12.000 33.104 to 120 0.0 0.0 0.0 206 110.34 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.34 33.144 KFactor= 19.17 106 110.03 4.26 0.0 12.000 33.144 to 120 0.0 0.0 0.0 107 110.03 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.03 33.184 KFactor= 19.10 - 206 0.23 2.635 2T 32.948 112.500 33.144 to 120 0.0 32.948 0.0 106 0.23 0.0 0.0 145.448 0.0 Vel = 0.01 0.0 0.23 33.144 K Factor = 0.04 206 110.11 4.26 0.0 12.000 33.144 to 120 0.0 0.0 0.0 207 110.11 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.11 33.184 KFactor= 19.11 107 110.07 4.26 0.0 12.000 33.184 to 120 0.0 0.0 0.0 108 110.07 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.07 33.224 KFactor= 19.10 207 0.04 2.635 2T 32.948 112.500 33.184 to 120 0.0 32.948 0.0 107 0.04 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.04 33.184 K Factor = 0.01 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 17 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 207 110.08 4.26 0.0 12.000 33.184 to 120 0.0 0.0 0.0 208 110.08 0.0033 0.0 12.000 0.040 VeI= 2.48 0.0 110.08 33.224 KFactor= 19.10 108 110.07 4.26 0.0 12.000 33.224 to 120 0.0 0.0 0.0 109 110.07 0.0033 0.0 12.000 0.040 Vel= 2.48 0.0 110.07 33.264 K Factor= 19.08 208 0.0 2.635 2T 32.948 112.500 33.224 to 120 0.0 32.948 0.0 108 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 33.224 K Factor = 0 208 110.07 4.26 0.0 12.000 33.224 to 120 0.0 0.0 0.0 209 110.07 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.07 33.264 K Factor= 19.08 109 110.07 4.26 0.0 12.000 33.264 to 120 0.0 0.0 0.0 110 110.07 0.0033 0.0 12.000 0.040 Vel= 2.48 0.0 110.07 33.304 K Factor= 19.07 209 0.0 2.635 2T 32.948 112.500 33.264 to 120 0.0 32.948 0.0 109 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 33.264 K Factor = 0 209 110.07 4.26 0.0 12.000 33.264 to 120 0.0 0.0 0.0 210 110.07 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.07 33.304 KFactor= 19.07 110 110.07 4.26 0.0 12.000 33.304 to 120 0.0 0.0 0.0 111 110.07 0.0032 0.0 12.000 0.039 Vel = 2.48 0.0 110.07 33.343 KFactor= 19.06 210 0.0 2.635 21 32.948 112.500 33.304 to 120 0.0 32.948 0.0 110 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 33.304 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 18 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 210 110.07 4.26 0.0 12.000 33.304 to 120 0.0 0.0 0.0 211 110.07 0.0032 0.0 12.000 0.039 Vel= 2.48 0.0 110.07 33.343 KFactor= 19.06 111 110.07 4.26 0.0 12.000 33.343 to 120 0.0 0.0 0.0 112 110.07 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.07 33.383 KFactor= 19.05 211 0.0 2.635 2T 32.948 112.500 33.343 to 120 0.0 32.948 0.0 111 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 33.343 K Factor =0 211 110.07 4.26 0.0 12.000 33.343 to 120 0.0 0.0 0.0 212 110.07 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.07 33.383 K Factor = 19.05 112 110.07 4.26 0.0 12.000 33.383 to 120 0.0 0.0 0.0 113 110.07 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.07 33.423 KFactor= 19.04 212 0.0 2.635 2T 32.948 112.500 33.383 to 120 0.0 32.948 0.0 112 0.0 0.0 0.0 145.448 0.0 Vel =0 0.0 0.0 33.383 K Factor = 0 212 110.07 4.26 0.0 12.000 33.383 to 120 0.0 0.0 0.0 213 110.07 0.0033 0.0 12.000 0.040 Vel= 2.48 0.0 110.07 33.423 KFactor= 19.04 113 110.07 4.26 0.0 12.000 33.423 to 120 0.0 0.0 0.0 114 110.07 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.07 33.463 K Factor = 19.03 213 0.0 2.635 2T 32.948 112.500 33.423 to 120 0.0 32.948 0.0 113 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 33.423 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 19 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 213 110.07 4.26 0.0 12.000 33.423 to 120 0.0 0.0 0.0 214 110.07 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.07 33.463 K Factor= 19.03 114 110.07 4.26 0.0 12.333 33.463 to 120 0.0 0.0 0.0 115 110.07 0.0033 0.0 12.333 0.041 Vel= 2.48 0.0 110.07 33.504 KFactor= 19.02 214 0.0 2.635 21 32.948 112.500 33.463 to 120 0.0 32.948 0.0 114 0.0 0.0 0.0 145.448 0.0 Vel =0 0.0 0.0 33.463 K Factor = 0 214 110.07 4.26 0.0 12.333 33.463 to 120 0.0 0.0 0.0 215 110.07 0.0033 0.0 12.333 0.041 VeI= 2.48 0.0 110.07 33.504 KFactor= 19.02 115 110.07 4.26 0.0 12.000 33.504 to 120 0.0 0.0 0.0 116 110.07 0.0032 0.0 12.000 0.039 Vel = 2.48 0.0 110.07 33.543 KFactor= 19.01 215 0.0 1.61 2T 16.0 112.500 33.504 to 120 0.0 16.000 0.0 115 0.0 0.0 0.0 128.500 0.0 Vel =0 0.0 0.0 33.504 K Factor = 0 215 110.07 4.26 0.0 12.000 33.504 to 120 0.0 0.0 0.0 216 110.07 0.0032 0.0 12.000 0.039 VeI= 2.48 0.0 110.07 33.543 K Factor= 19.01 116 110.07 4.26 0.0 12.000 33.543 to 120 0.0 0.0 0.0 117 110.07 0.0033 0.0 12.000 0.040 Vel= 2.48 0.0 110.07 33.583 K Factor= 18.99 216 0.0 1.61 21 16.0 112.500 33.543 to 120 0.0 16.000 0.0 116 0.0 0.0 0.0 128.500 0.0 Vel = 0 0.0 0.0 33.543 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 20 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 216 110.07 4.26 0.0 12.000 33.543 to 120 0.0 0.0 0.0 217 110.07 0.0033 0.0 12.000 0.040 Vel= 2.48 0.0 110.07 33.583 KFactor= 18.99 117 110.07 4.26 0.0 12.000 33.583 to 120 0.0 0.0 0.0 118 110.07 0.0033 0.0 12.000 0.040 VeI= 2.48 0.0 110.07 33.623 K Factor = 18.98 217 0.0 1.61 2T 16.0 112.500 33.583 to 120 0.0 16.000 0.0 117 0.0 0.0 0.0 128.500 0.0 Vel=0 0.0 0.0 33.583 K Factor = 0 217 110.07 4.26 0.0 12.000 33.583 to 120 0.0 0.0 0.0 218 110.07 0.0033 0.0 12.000 0.040 Vel= 2.48 0.0 110.07 33.623 K Factor= 18.98 118 110.08 4.26 0.0 12.000 33.623 to 120 0.0 0.0 0.0 119 110.08 0.0033 0.0 12.000 0.040 Vel= 2.48 0.0 110.08 33.663 K Factor= 18.97 218 0.0 1.61 2T 16.0 112.500 33.623 to 120 0.0 16.000 0.0 118 0.0 0.0 0.0 128.500 0.0 VeI=0 0.0 0.0 33.623 K Factor = 0 218 110.07 4.26 0.0 12.000 33.623 to 120 0.0 0.0 0.0 219 - 110.07 0.0033 0.0 12.000 0.040 Vel= 2.48 0.0 110.07 33.663 KFactor= 18.97 119 110.09 4.26 0.0 12.000 33.663 to 120 0.0 0.0 0.0 120 110.09 0.0032 0.0 12.000 0.039 Vel= 2.48 0.0 110.09 33.702 K Factor= 18.96 219 0.01 1.61 2T 16.0 112.500 33.663 to 120 0.0 16.000 0.0 119 0.01 0.0 0.0 128.500 0.0 VeI=0 0.0 0.01 33.663 K Factor =0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 21 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 219 110.06 4.26 0.0 12.000 33.663 to 120 0.0 0.0 0.0 220 110.06 0.0032 0.0 12.000 0.039 Vel = 2.48 0.0 110.06 33.702 K Factor= 18.96 120 110.12 4.26 0.0 12.000 33.702 to 120 0.0 0.0 0.0 121 110.12 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.12 33.742 KFactor= 18.96 220 0.04 1.61 2T 16.0 112.500 33.702 to 120 0.0 16.000 0.0 120 0.04 0.0 0.0 128.500 0.0 Vel = 0.01 0.0 0.04 33.702 K Factor= 0.01 220 110.02 4.26 0.0 12.000 33.702 to 120 0.0 0.0 0.0 221 110.02 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.02 33.742 KFactor = 18.94 121 110.21 4.26 0.0 12.000 33.742 to 120 0.0 0.0 0.0 122 110.21 0.0033 0.0 12.000 0.040 Vel = 2.48 0.0 110.21 33.782 K Factor = 18.96 221 0.09 1.61 2T 16.0 112.500 33.742 to 120 0.0 16.000 0.0 121 0.09 0.0 0.0 128.500 0.0 Vel = 0.01 0.0 0.09 33.742 K Factor= 0.02 221 109.94 4.26 0.0 12.000 33.742 to 120 0.0 0.0 0.0 222 109.94 0.0033 0.0 12.000 0.040 Vel = 2.47 0.0 109.94 33.782 K Factor= 18.92 122 110.37 4.26 0.0 12.000 33.782 to 120 0.0 0.0 0.0 123 110.37 0.0033 0.0 12.000 0.040 Vel= 2.48 0.0 110.37 33.822 K Factor= 18.98 222 0.16 1.61 21 16.0 112.500 33.782 to 120 0.0 16.000 0.0 122 0.16 0.0 0.0 128.500 0.0 Vel = 0.03 0.0 0.16 33.782 K Factor = 0.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 22 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Fin 222 109.78 4.26 0.0 12.000 33.782 to 120 0.0 0.0 0.0 223 109.78 0.0033 0.0 12.000 0.040 Vel = 2.47 0.0 109.78 33.822 K Factor = 18.88 123 110.62 4.26 0.0 12.000 33.822 to 120 0.0 0.0 0.0 124 110.62 0.0033 0.0 12.000 0.040 Vel= 2.49 0.0 110.62 33.862 KFactor= 1901 223 0.26 1.61 2T 16.0 112.500 33.822 to 120 0.0 16.000 0.0 123 0.26 0.0 0.0 128.500 0.0 Vel = 0.04 0.0 0.26 33.822 K Factor = 0.04 223 109.52 4.26 0.0 12.000 33.822 to 120 0.0 0.0 0.0 224 109.52 0.0032 0.0 12.000 0.039 Vel = 2.47 0.0 109.52 33.861 KFactor= 18.82 124 111.01 4.26 0.0 12.000 33.862 to 120 0.0 0.0 0.0 125 111.01 0.0034 0.0 12.000 0.041 Vel= 2.50 0.0 111.01 33.903 K Factor = 19.07 224 0.39 1.61 2T 16.0 112.500 33.861 to 120 0.0 16.000 0.0 124 0.39 0.0 0.0 128.500 0.001 Vel = 0.06 0.0 0.39 33.862 K Factor = 0.07 224 109.14 4.26 0.0 12.000 33.861 to 120 0.0 0.0 0.0 225 109.14 0.0032 0.0 12.000 0.039 Vel = 2.46 0.0 109.14 33.900 KFactor= 18.74 125 111.55 4.26 0.0 12.000 33.903 to 120 0.0 0.0 0.0 126 111.55 0.0034 0.0 12.000 0.041 Vel = 2.51 0.0 111.55 33.944 K Factor = 19.15 225 0.54 1.61 2T 16.0 112.500 33.900 to 120 0.0 16.000 0.0 125 0.54 0.0 0.0 128.500 0.003 Vel = 0.09 0.0 0.54 33.903 K Factor = 0.09 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 23 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 225 108.59 4.26 0.0 12.000 33.900 to 120 0.0 0.0 0.0 226 108.59 0.0032 0.0 12.000 0.039 Vel = 2.44 0.0 108.59 33.939 K Factor= 18.64 126 112.29 4.26 0.0 10.167 33.944 to 120 0.0 0.0 0.0 127 112.29 0.0033 0.0 10.167 0.034 Vel = 2.53 0.0 112.29 33.978 KFactor= 19.26 226 0.74 1.61 2T 16.0 112.500 33.939 to 1120 0.0 16.000 0.0 126 0.74 0.0 0.0 128.500 0.005 Vel = 0.12 0.0 0.74 33.944 K Factor = 0.13 226 107.86 4.26 0.0 10.167 33.939 to 120 0.0 0.0 0.0 227 107.86 0.0031 0.0 10.167 0.032 VeI= 2.43 0.0 107.86 33.971 KFactor= 18.51 127 113.22 4.26 11 9.217 9.167 33.978 to 120 0.0 9.217 0.0 128 113.22 0.0035 0.0 18.384 0.065 Vel= 2.55 0.0 113.22 34.043 K Factor = 19.40 227 0.93 1.61 2T 16.0 112.500 33.971 to 120 0.0 16.000 0.0 127 0.93 0.0001 0.0 128.500 0.007 Vel = 0.15 0.0 0.93 33.978 KFactor= 0.16 227 106.92 4.26 II 9.217 9.167 33.971 to 120 0.0 9.217 0.0 228 106.92 0.0032 0.0 18.384 0.058 Vel = 2.41 0.0 106.92 - 34.029 KFactor= 18.33 128 113.22 4.26 11 26.334 49.833 34.043 to 120 0.0 26.334 0.0 328 113.22 0.0035 0.0 76.167 0.266 Vel = 2.55 0.0 113.22 34.309 K Factor = 19.33 228 106.92 4.26 iT 26.334 62.667 34.029 to 120 0.0 26.334 0.0 328 106.92 0.0031 0.0 89.001 0.280 Vel = 2.41 328 113.23 6.357 11 12.573 3.000 34.309 to 120 0.0 12.573 0.0 R-T 220.15 0.0017 0.0 15.573 0.026 Vel = 2.23 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 24 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn R-T 0.0 6.357 lAla 33.948 21.417 34.335 to 120 0.0 33.948 9.276 R-B 220.15 0.0017 0.0 55.365 0.094 Vel = 2.23 R-B 100.00 6.16 IM 17.215 14.000 43.705 Qa = 100 to 140 0.0 17.215 1.732 Ui 320.15 0.0030 0.0 31.215 0.094 Vel= 3.45 UI 0.0 6.09 2F 21.583 60.000 45.531 to 150 1M 18.5 90.957 6.280 U2 320.15 0.0028 1G 4.625 150.957 0.418 Vel = 3.53 iT 46.249 U2 0.0 7.98 1M 24.162 197.000 52.229 to 150 0.0 24.162 1.299 BFI 320.15 0.0007 0.0 221.162 0.165 Vel= 2.05 BFI 0.0 8.27 0.0 8.000 53.693 to 140 0.0 0.0 8.000 * Fixed loss = 8 BF2 320.15 0.0008 0.0 8.000 0.006 Vel = 1.91 BF2 400.00 7.98 2M 48.325 4.000 61.699 Qa=400 to 150 0.0 48.325 0.0 U3 720.15 0.0033 0.0 52.325 0.174 VeI= 4.62 U3 0.0 7.98 1M 24.162 46.500 61.873 to 150 1 52.855 83.057 0.0 SOR 720.15 0.0033 1G 6.041 129.557 0.432 Vel = 4.62 0.0 720.15 62.305 K Factor= 91.24 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 F.W.. iI.M. q Fire Protection by Computer Design COSCO Fire Protection, Inc. 321 East Gardena Blvd. Gardena, CA. 90247 (323) 321-5155 .60 Jjt,,s;4-y € M o s4- Rxwo+e 900 s4 Job Name : TARGET Warehouse- Carlsbad Drawing : Off-Site Warehouse Location : 6231 Yarrow Drive, Suite C, Carlsbad, CA. Remote Area : WEST-side Contract : #1 5GS-0463 Data File : TARGET WhseK11-2K_900-Remote.wxf Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 IL COSCO Fire Protection, Inc. TARGET Warehouse- Carlsbad Page 1 Date 8-20-09 Hydraulic Design Information Sheet Name - TARGET Warehouse T1029 - Carlsbad > .60 / 900 SF Date - 9-21-09 Location - 6231 Yarrow Drive, Suite C, Carlsbad, CA. Building - Off-Site Warehouse System No. - WEST-side Contractor - COSCO FIRE PROTECTION, INC. Contract No. - #15GS-0463 Calculated By - Mike Coughlin Drawing No. - FP-1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 251 -0" Occupancy - STORAGE WAREHOUSE w/ Racks & Shelves S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 C Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure S Other T Specific Ruling 0.60 GPM / 900 sq.ft. Made By TELGIAN H ) 3 (X) Ex.Haz. Curve Date 8-6-09 M Area of Sprinkler Operation - 944 System Type Sprinkler/Nozzle Density - 0.60 (X) Wet Make Reliable D Area Per Sprinkler - 100 (max. ( ) Dry Model "G-XLO" E Elevation at Highest Outlet - 24.042' ( ) Deluge Size 3/4" S Hose Allowance - Inside - 100 ( ) Preaction K-Factor 11.2 I Rack Sprinkler Allowance - N.A. ( ) Other Temp.Rat.= 165 G Hose Allowance - Outside - 400 N Note Calculation Flow Required - 1072.45 Press Required - 62.39 Summary C-Factor Used: 120 Overhead 140 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 4-15-08 Cap. - T Time of Test - N.A. Rated Cap.- Elev.- E Static Press - 124 @ Press - R Residual Press - 118 Elev. - Well Flow - 1060 Proof Flow S Elevation - -18.0' U P Location - 6231 Yarrow Dr., Carlsbad Fire Dept. P NOTE: Hydr. Calc.s input = Reduced by 10% L Source of Information - Hydr. Calc.s by West Coast Fire Prot. (3-2-09) Y per Brenda 8 Carlsbad Fire Dept. (8-25-09) C Commodity Retail Products Storage Class I-IV w/ Location O Storage Ht. 151 -0"' Area 8' Aisle W. M Storage Method: Solid Piled % Palletized 80 % Rack M Single Row (X) Conven. Pallet ( ) Auto. Storage (X) Encap. S R (X) Double Row ( ) Slave Pallet C ) Solid Shelf ( ) Non T A ( ) Mult. Row (X) Open Shelf O C R K Flue Spacing 0-8" Clearance:Storage to Ceiling 81 -0" A Longitudinal Transverse G E Horizontal Barriers Provided: >> See attached TARGET plan: F911 Water Supply Curve (C) COSCO Fire Protection, Inc. Page 2 TARGET Warehouse- Carlsbad Date 8-20-09 City Water Supply: Cl - Static • ressure : 111.6 C2 Th J4_ F 'e- r Demand: Dl - Elevation : 19.508 - Residual Pressure: 105.6 D2 - System Flow : 572.45 C2 - Residual Flow : 1060 j j J D2 - System Pressure Hose (Adj City) : 62.386 Hose ( Demand) : 500 D3 - System Demand : 1072.45 Safety Margin : 43.083 150 140 130 p 120 Cl R 110 E 100 S90 S80 U 70 R 60 E 50 40 30 20 Dl 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N ' 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary COSCO Fire Protection, Inc. Page 3 TARGET Warehouse- Carlsbad Date 8-20-09 Fitting Legend Abbrev.Name Y2 % 1 1% 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 Ala Generic Alarm Valve 0 0 0 0 0 0 7.7 21.5 0 17 17 27 29 0 0 0 0 0 0 0 F 45Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90 Ell Grvd-Vic#10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 M Medium Turn Elbow 0 2 2 3 3 4 5 6 6 8 10 12 16 19 22 0 0 0 0 0 1 90 Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 LJLISSS.FLII I _,_l nay.... — € Model GXLO Reliable Extra Large Orifice Sprinkler w (D r\D (0 ME Extra Large Orifice Sprinkler (SIN R2921) Features The Reliable Model G XLO sprinkler offers the opportunity for: Pipe size reduction Fewer sprinklers 3BiminaflonoLboosteLpumps.. - 4. Increasing densities with existing systems Y2 NPT (R1/2) available for retrofit installations only. Also includes additional Specific Application listing. (See detailed "UL Specification Application listing" described on the back page.) Listings & Approvals: Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories' of Canada (ULC) Approved by Factory Mutual (FM) I 4. NYC MEA 258-93-E (NFPA 13*). UL Guide Number VNIV UL Listing Category Sprinklers, Automatic & Open Extra Large Orifice Upright Sprinkler and Specific Application Sprinkler. Technical Data Sprinkler Nominal K Factor Sprinkler Type US Metric s He ight Approvals Identification Number (SIN) Upright 3.14 O.4 Orifice with 11.2 I 160 (80mm) 1,2,3,4 R2921 3/4 NPT(R3/4) UprightRetrollt 0.64 Orifice with 11.2{ 160 ( 3.25 m) 1,2,3,4 [ R2921 1/2 NPT(R½) Note: This product has been tested and listed for storage appli- cations to qualify its use in lieu of 5.6K or 8.0K Factor sprinklers for the protection of high-piled storage. Product Description The Reliable Model G XLO sprinkler is a center strut solder in compression extra large orifice upright sprinkler that has been designed to control high chal- lenge fires in both palletized and rack storage occu- pancies utilizing relatively low water pressures. This sprinkler is available with either the standard Y, NPT (A 3A) threads for new installations or with Y NPT (R½) threads for retrofit applications. It has been proven in full—scale fire testing, has com- plied with the applicable mechanical and hydraulic sections of the latest sprinkler standards and has Fac- tory Mutual Approval and Underwriters Laboratories and Underwriters Laboratories' of Canada Listings. This product is intended for use as a standard spray sprinkler in hydraulically designed systems with a minimum pressure of 7 psi (0.5 bar) in accor- dance with the area/density curves of NFPA 13* stan- dards and for all area/density methods of design as referenced by Factory Mutual (FM) Prevention Data Sheets. Design Criteria The following criteria apply when designing an automatic sprin- kler system utlizing the Model G XLO sprinkler for NFPA 13* applications. Sprinkler spacing shall be a minimum of 6 ft. (1.8m) Sprinklers with Y2 NFl (R1/2) are to be used for retrofit applications only. Sprinkler discharge pressure per NFPA 13* standards shall be a minimum of 7 psi (0,5 bar). Sprinkler discharge pressure for NFPA 13* standard and all Factory Mutual (FM) applications shall be a minimum of 10 psi (0.7 bar). Factory Mutual (FM) Loss Prevention Data Sheets contain requirements which differ from NFPA. The Model G XLO is Approved by Factory Mutual for all area/density methods of design as referenced by FM Loss Prevention Data Sheets. The Model (3 XLO Extra Large Orifice sprinkler is intended for standard flow/pressure requirements and standard place- ment as specified for NFPA storage requirements. The Model G XLO sprinkler is not a "Large Drop" or "ESFR" sprinkler. lemDerature Ratinas Sprinkler Maximum Ambient Classification Rating Temperature Frame Color °C OF Ordinary 165 I 74 100 I 38 Uncolored Intermediate 212 I 100 150 I 66 White High 286 J 141 225 107 Blue *For sprinkler standards prior to 1999 edition of NFPA 13, use NFPA standards 231, 231C, 231D & 231F. The Reliable Automatic Sprinkler Co., Inc • 525 North MacQuesten Parkway • Mount Vernon . New York •10552 Finishes Standard Finishes Bronze Chrome Special Application Finishes Lead Plated -165 F(74 C), 212 F (100 C) and 286 F(141 C) Temp. Ratings Wax' -165 F(74 C)Clear Wax, 212 F (100 C) Brown Wax WaQLead - 165 F(74 C) Clear Wax, 212 F (100 C) Brown Wax UL Usted only. (2) 212 F (100 C) Brown wax may be used on 286 F (141 C) Sprinklers when maximum ambient temperatures do not exceed 150 F (66 C). Maintenance Model G XLO Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera-tion or non-operation. Ordering Information Specify: The UL Specific Application Listing is: 1. Sprinkler Model The Model G Qu kler rit ded far use in 2. Temperature Rating - ---- ---------- -- - accordance with the standard sprinkler positioning and area/density flow calculation requirements as specified in each respective standard. Model C XLO upright sprinklers may also be installed to protect single, double and multiple - row and portable rack storage of Class WV, Groups A and B plastics, cartoned, expanded or unexpanded, as well as exposed unexpanded with a maximum storage height of 20 ft. (6.5m), maximum ceiling height of 25 ft. (8.2m) or 27" ft (8.8m) maximum ceiling height 36 (914mm) minimum deflector to top of storage clearance, design density of 0.60 gprrV ff. (24.7 Lknir*n2) and a design area of 2000 ft'. (186m) for wet systems and 2600 ff. (242rn) for dry systems. Note: Maximum 27ft ceilling height is allowed by NFPA 13*, Mthout in-rack sprinklers in a protected area, provided the ceiling sprinklers' discharge is increased to 0.6 gprrilft2 in a 2000 ft2 design area. Model H Sprinkler Wrench Use only the Model H sprinkler wrench for S prinkler removal and installation Any other type of wrench may damage the spnnkler. Installation Reliable's Model G XLO sprinkler must be installed according to NFPA Standards or the appropriate Factory Mutual Loss Prevention Data Sheets for all area/density methods of design as well as the Authority Having Jurisdiction. The Model GXLO sprinkler meets the NFPA 13* code stan-dards for approval by Factory Mutual and listings by Under- writers Laboratories & Underwriters Laboratories of Canada [82.6m,,,] (j/" NRT) 2.77" -1. 14 (5/4" wpr) (7/2" NPT) 2.82 2.25" (i(712 , wPr) (71.6mm] [t&8mmJ f79.Bmmj 1.87" I47..mInj * For sprinkler standards prior to 1999 edition of NFPA 13, use NFPA standards 231, 231C, 231D & 231F. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions 01 governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices www.reliablesprinkter.com Internet Address Revision lines indicate updated or new data. PG. Printed in U.S.A. 06/02 P/N9999970022 Pressure / Flow Summary - STANDARD COSCO Fire Protection, Inc. Page 4 TARGET Warehouse- Carlsbad Date 8-20-09 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 101 21.917 23.39 na W1L 21.917 20.23 na Wi 24.042 11.2 15.44 na 44.01 0.6 72.664 15.153 W21- 21.917 19.98 na W2 24.042 11.2 15.24 na 43.72 0.6 72.664 15.153 W3L 21.917 19.89 na W3 24.042 11.2 15.16 na 43.61 0.6 72.664 15.153 W41- 21.917 19.88 na W4 24.042 11.2 15.15 na 43.6 0.6 72.664 15.153 W5L 21.917 19.9 na W5 24.042 11.2 15.17 na 43.62 0.6 72.664 15.153 W61- 21.917 20.02 na W6 24.042 11.2 15.27 na 43.76 0.6 72.664 15.153 W71- 21.917 20.31 na W7 24.042 11.2 15.5 na 44.1 0.6 72.664 15.153 201 21.917 23.31 na 102 21.917 23.44 na W81- 21.917 21.22 na W8 24.042 20.29 na W91- 21.917 20.65 na W9 24.042 11.2 15.78 na 44.49 0.6 72.664 15.153 W10L 21.917 20.41 na W10 24.042 11.2 15.58 na 44.21 0.6 72.664 15.153 WilL 21.917 20.36 na Wil 24.042 11.2 15.54 na 44.15 0.6 72.664 15.153 W12L 21.917 20.36 na W12 24.042 11.2 15.54 na 44.16 0.6 72.664 15.153 W13L 21.917 20.49 na W13 24.042 11.2 15.65 na 44.3 0.6 72.664 15.153 W14L 21.917 20.86 na W14 24.042 11.2 15.95 na 44.73 0.6 72.664 15.153 202 21.917 23.36 na 103 21.917 23.63 na W1 5L 21.917 23.62 na W15 24.042 22.7 na W16L 21.917 23.61 na W16 24.042 22.69 na W17L 21.917 23.61 na W17 24.042 22.69 na W18L 21.917 23.61 na W18 24.042 22.69 na W19L 21.917 23.61 na W19 24.042 22.69 na W20L 21.917 23.61 na W20 24.042 22.69 na W2IL 21.917 23.6 na W21 24.042 22.68 na 203 21.917 23.59 na 104 21.917 23.85 na W22L 21.917 23.85 na W22 24.042 22.93 na W23L 21.917 23.85 na W23 24.042 22.93 na W24L 21.917 23.84 na W24 24.042 22.92 na W25L 21.917 23.84 na W25 24.042 22.92 na W26L 21.917 23.84 na W26 24.042 22.92 na W27L 21.917 23.84 na W27 24.042 22.92 na W28L 21.917 23.84 na W28 24.042 22.92 na 204 21.917 23.84 na 105 21.917 24.08 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard COSCO Fire Protection, Inc. Page 5 TARGET Warehouse- Carlsbad Date 8-20-09 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. W29L 21.917 24.08 na W29 24.042 23.16 na W30L 21.917 24.08 na W30 24.042 23.16 na W31 21.917 24.08 na W31 24.042 23.16 na W32L 21.917 24.08 na W32 24.042 23.16 na W33L 21.917 24.08 na W33 24.042 23.16 na W34L 21.917 24.08 na W34 24.042 23.16 na W35L 21.917 24.08 na W35 24.042 23.16 na 205 21.917 24.08 na 106 21.917 24.31 na 206 21.917 24.31 na 107 21.917 24.54 na 207 21.917 24.54 na 108 21.917 24.78 na 208 21.917 24.78 na 109 21.917 25.01 na 209 21.917 25.01 na 110 21.917 25.24 na 210 21.917 25.24 na 111 21.917 25.48 na 211 21.917 25.48 na 112 21.917 25.71 na 212 21.917 25.71 na 113 21.917 25.94 na 213 21.917 25.94 na 114 21.917 26.18 na 214 21.917 26.18 na 115 21.917 26.41 na 215 21.917 26.41 na 116 21.917 26.65 na 216 21.917 26.65 na 117 21.917 26.88 na 217 21.917 26.88 na 118 21.917 27.11 na 218 21.917 27.11 na 119 21.917 27.35 na 219 21.917 27.35 na 120 21.917 27.58 na 220 21.917 27.58 na 121 21.917 27.81 na 221 21.917 27.81 na 122 21.917 28.05 na 222 21.917 28.05 na 123 21.917 28.28 na 223 21.917 28.28 na 124 21.917 28.52 na 224 21.917 28.51 na 125 21.917 28.75 na 225 21.917 28.74 na 126 21.917 28.99 na 226 21.917 28.97 na 127 21.917 29.2 na 227 21.917 29.16 na 128 21.917 29.57 na 228 21.917 29.49 na 328 21.917 31.13 na R-T 21.917 31.29 na R-B 0.5 41.12 na 100.0 U -3.5 43.22 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard COSCO Fire Protection, Inc. Page 6 TARGET Warehouse- Carlsbad Date 8-20-09 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. U2 -18.0 51.15 na BF1 -21.0 53.1 na BF2 -21.0 61.12 na 400.0 U3 -21.0 61.48 na SOR -21.0 62.39 na The maximum velocity is 16.6 and it occurs in the pipe between nodes W14 and WI4L Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 7 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 101 148.56 4.26 0.0 8.417 23.388 to 120 0.0 0.0 0.0 102 148.56 0.0058 0.0 8.417 0.049 Vel = 3.34 0.0 148.56 23.437 K Factor= 30.69 W1L 148.56 2.635 IT 16.474 36.250 20.230 to 120 0.0 16.474 0.0 101 148.56 0.0599 0.0 52.724 3.158 Vel = 8.74 0.0 148.56 23.388 K Factor= 30.72 Wi 44.01 1.049 IT 5.0 1.917 15.438 KFactor= 11.20 to 120 0.0 5.000 0.920 W1L 44.01 0.5598 0.0 6.917 3.872 Vel= 16.34 0.0 44.01 20.230 K Factor= 9.78 W2L 104.55 2.635 0.0 8.000 19.980 to 120 0.0 0.0 0.0 W1L 104.55 0.0312 0.0 8.000 0.250 Vel = 6.15 0.0 104.55 20.230 K Factor= 23.24 W2 43.72 1.049 IT 5.0 1.917 15.235 K Factor= 11.20 to 120 0.0 5.000 0.920 W2L 43.72 0.5530 0.0 6.917 3.825 Vel = 16.23 0.0 43.72 19.980 K Factor= 9.78 WK 60.84 2.635 0.0 8.000 19.888 to 120 0.0 0.0 0.0 W2L 60.84 0.0115 0.0 8.000 0.092 Vel = 3.58 0.0 60.84 19.980 K Factor= 13.61 W3 43.61 1.049 IT 5.0 1.917 15.160 K Factor = 11.20 to 120 0.0 5.000 0.920 WK 43.61 0.5505 0.0 6.917 3.808 Vel = 16.19 0.0 43.61 19.888 K Factor = 9.78 W4L 17.23 2.635 0.0 8.000 19.879 to 120 0.0 0.0 0.0 WK 17.23 0.0011 0.0 8.000 0.009 Vel= 1.01 0.0 17.23 19.888 K Factor = 3.86 W4 43.60 1.049 IT 5.0 1.917 15.153 K Factor= 11.20 to 120 0.0 5.000 0.920 W4L 43.6 0.5502 0.0 6.917 3.806 Vel = 16.19 0.0 43.60 19.879 K Factor = 9.78 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 8 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W5L -26.37 2.635 0.0 8.000 19.899 to 120 0.0 0.0 0.0 W4L -26.37 -0.0025 0.0 8.000 -0.020 Vel = 1.55 0.0 -26.37 19.879 K Factor= -5.91 W5 43.62 1.049 iT 5.0 1.917 15.169 K Factor = 11.20 to 120 0.0 5.000 0.920 W5L 43.62 0.5508 0.0 6.917 3.810 Vel = 16.19 0.0 43.62 19.899 KFactor= 9.78 W6L -69.99 2.635 0.0 8.000 20.018 to 120 0.0 0.0 0.0 W5L -69.99 -0.0149 0.0 8.000 -0.119 Vel = 4.12 0.0 -69.99 19.899 K Factor = -15.69 W6 43.76 1.049 iT 5.0 1.917 15.266 K Factor= 11.20 to 120 0.0 5.000 0.920 WK 43.76 0.5540 0.0 6.917 3.832 Vel = 16.24 0.0 43.76 20.018 K Factor = 9.78 W7L -113.75 2.635 0.0 8.000 20.310 to 120 0.0 0.0 0.0 W6L -113.75 -0.0365 0.0 8.000 -0.292 Vel = 6.69 0.0 -113.75 20.018 K Factor = -25.42 W7 44.10 1.049 iT 5.0 1.917 15.503 K Factor = 11.20 to 120 0.0 5.000 0.920 W7L 44.1 0.5619 0.0 6.917 3.887 Vel = 16.37 0.0 44.10 20.310 K Factor = 9.79 201 -157.85 2.635 1 16.474 28.250 23.308 to 120 0.0 16.474 0.0 W7L -157.85 -0.0670 0.0 44.724 -2.998 Vel = 9.29 0.0 -157.85 20.310 K Factor = -35.03 201 157.85 4.26 0.0 8.417 23.308 to 120 0.0 0.0 0.0 202 157.85 0.0064 0.0 8.417 0.054 Vel = 3.55 0.0 157.85 23.362 K Factor= 32.66 102 271.40 4.26 0.0 10.875 23.437 to 120 0.0 0.0 0.0 103 271.4 0.0177 0.0 10.875 0.192 VeI= 6.11 0.0 271.40 23.629 K Factor= 55.83 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 9 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total - Pf Pn W8L 122.84 2.635 IT 16.474 36.250 21.215 to 120 0.0 16.474 0.0 102 122.84 0.0421 0.0 52.724 2.222 VeI= 7.23 0.0 122.84 23.437 K Factor= 25.37 W8 0.0 1.049 IT 5.0 1.917 20.295 to 120 0.0 5.000 0.920 W8L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 21.215 K Factor =0 W9L 122.84 2.635 0.0 13.333 20.653 to 120 0.0 0.0 0.0 W8L 122.84 0.0422 0.0 13.333 0.562 Vel = 7.23 0.0 122.84 21.215 KFactor= 26.67 W9 44.49 1.049 IT 5.0 1.917 15.782 KFactor= 11.20 to 120 0.0 5.000 0.920 W9L 44.49 0.5712 0.0 6.917 3.951 Vel = 16.52 0.0 44.49 20.653 K Factor= 9.79 WIOL 78.34 2.635 0.0 13.333 20.409 to 120 0.0 0.0 0.0 W9L 78.34 0.0183 0.0 13.333 0.244 Vel = 4.61 0.0 78.34 20.653 K Factor= 17.24 WIO 44.21 1.049 1 5.0 1.917 15.583 K Factor= 11.20 to 120 0.0 5.000 0.920 W10L 44.21 0.5647 0.0 6.917 3.906 Vel = 16.41 0.0 44.21 20.409 K Factor = 9.79 WilL 34.13 2.635 0.0 13.333 20.356 to 120 0.0 0.0 0.0 W1OL 34.13 0.0040 0.0 13.333 0.053 Vel = 2.01 0.0 34.13 20.409 K Factor = 7.55 Wil 44.15 1.049 1 5.0 1.917 15.540 KFactor= 11.20 to 120 0.0 5.000 0.920 WilL 44.15 0.5632 0.0 6.917 3.896 Vel = 16.39 0.0 44.15 20.356 KFactor= 9.79 W12L -10.02 2.635 0.0 13.333 20.362 to 120 0.0 0.0 0.0 WilL -10.02 -0.0005 0.0 13.333 -0.006 Vel = 0.59 0.0 -10.02 20.356 K Factor= -2.22 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 10 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W12 44.16 1.049 IT 5.0 1.917 15.545 K Factor= 11.20 to 120 0.0 5.000 0.920 W12L 44.16 0.5634 0.0 6.917 3.897 Vel = 16.39 0.0 44.16 20.362 K Factor = 9.79 W1 3L -54.18 2.635 0.0 13.333 20.485 to 120 0.0 . 0.0 0.0 W1 2L -54.18 -0.0092 0.0 13.333 -0.123 Vel = 3.19 0.0 -54.18 20.362 K Factor = -12.01 W13 44.30 1.049 iT 5.0 1.917 15.645 K Factor= 11.20 to 120 0.0 5.000 0.920 W1 3L 44.3 0.5667 0.0 6.917 3.920 Vel = 16.45 0.0 44.30 20.485 K Factor = 9.79 W14L -98.48 2.635 0.0 13.333 20.859 to 120 0.0 0.0 0.0 W1 3L -98.48 -0.0281 0.0 13.333 -0.374 Vel = 5.79 0.0 -98.48 20.485 K Factor = -21.76 W14 44.73 1.049 iT 5.0 1.917 15.948 KFactor= 11.20 to 120 0.0 5.000 0.920 W14L 44.73 0.5770 0.0 6.917 3.991 Vel = 16.60 0.0 44.73 20.859 K Factor = 9.79 202 -143.21 2.635 iT 16.474 28.250 23.362 to 120 0.0 16.474 0.0 W14L -143.21 -0.0560 0.0 44.724 -2.503 Vel = 8.43 0.0 -143.21 20.859 K Factor = -31.36 202 301.06 4.26 0.0 10.875 23.362 to 120 0.0 0.0 0.0 203 301.06 0.0213 0.0 10.875 0.232 Vel = 6.78 0.0 301.06 23.594 KFactor= 61.98 103 278.88 4.26 0.0 12.000 23.629 to 120 0.0 0.0 0.0 104 278.88 0.0185 0.0 12.000 0.222 Vel = 6.28 0.0 278.88 23.851 K Factor= 57.10 W1 5L 7.48 2.635 iT 16.474 36.250 23.616 to 120 0.0 16.474 0.0 103 7.48 0.0002 0.0 52.724 0.013 Vel = 0.44 0.0 7.48 23.629 K Factor= 1.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 11 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W15 0.0 1.049 IT 5.0 1.917 22.696 to 120 0.0 5.000 0.920 W1 5L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 23.616 K Factor = 0 W16L 7.48 2.635 0.0 8.000 23.614 to 120 0.0 0.0 0.0 W1 5L 7.48 0.0002 0.0 8.000 0.002 Vel = 0.44 0.0 7.48 23.616 KFactor= 1.54 W16 0.0 1.049 1 5.0 1.917 22.694 to 120 0.0 5.000 0.920 WI6L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 23.614 K Factor =0 W1 7L 7.48 2.635 0.0 8.000 23.612 to 120 0.0 0.0 0.0 WI6L 7.48 0.0002 0.0 8.000 0.002 Vel = 0.44 0.0 7.48 23.614 K Factor= 1.54 W17 0.0 1.049 1 5.0 1.917 22.692 to 120 0.0 5.000 0.920 W1 7L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 23.612 K Factor =0 W1 8L 7.48 2.635 0.0 8.000 23.610 to 120 0.0 0.0 0.0 W17L 7.48 0.0002 0.0 8.000 0.002 Vel = 0.44 0.0 7.48 23.612 K Factor = 1.54 W18 0.0 1.049 iT 5.0 1.917 22.690 to 120 0.0 5.000 0.920 W1 8L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 23.610 K Factor = 0 W1 9L 7.48 2.635 0.0 8.000 23.608 to 120 0.0 0.0 0.0 W1 8L 7.48 0.0002 0.0 8.000 0.002 Vel = 0.44 0.0 7.48 23.610 KFactor= 1.54 Wig 0.0 1.049 1 5.0 1.917 22.688 to 120 0.0 5.000 0.920 W1 9L 0.0 0.0 0.0 6.917 0.0 Vel = 0 - 0.0 0.0 23.608 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 12 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W20L 7.48 2.635 0.0 8.000 23.606 to 120 0.0 0.0 0.0 W1 9L 7.48 0.0002 0.0 8.000 0.002 Vel = 0.44 0.0 7.48 23.608 K Factor = 1.54 W20 0.0 1.049 iT 5.0 1.917 22.686 to 120 0.0 5.000 0.920 W20L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 23.606 K Factor = 0 W21 7.48 2.635 0.0 8.000 23.605 to 120 0.0 0.0 0.0 W20L 7.48 0.0001 0.0 8.000 0.001 Vel = 0.44 0.0 7.48 23.606 K Factor= 1.54 W21 0.0 1.049 iT 5.0 1.917 22.684 to 120 0.0 5.000 0.920 W21 0.0 0.0001 0.0 6.917 0.001 Vel =0 0.0 0.0 23.605 K Factor = 0 203 7.48 2.635 1 16.474 28.250 23.594 to 120 0.0 16.474 0.0 W21 L 7.48 0.0002 0.0 44.724 0.011 Vel = 0.44 0.0 7.48 23.605 KFactor= 1.54 203 293.58 4.26 0.0 12.000 23.594 to 120 0.0 0.0 0.0 204 293.58 0.0203 0.0 12.000 0.244 Vel = 6.61 0.0 293.58 23.838 K Factor = 60.13 104 283.19 4.26 0.0 12.000 23.851 to 120 0.0 0.0 0.0 105 283.19 0.0190 0.0 12.000 0.228 Vel = 6.37 0.0 283.19 24.079 K Factor= 57.71 W22L 4.31 2.635 iT 16.474 36.250 23.846 to 120 0.0 16.474 0.0 104 4.31 0.0001 0.0 52.724 0.005 Vel = 0.25 0.0 4.31 23.851 K Factor= 0.88 W22 0.0 1.049 iT 5.0 1.917 22.926 to 120 0.0 5.000 0.920 W22L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 23.846 K Factor =0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 13 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pt/Ft Eqv. Ln. Total Pf Pn W23L 4.31 2.635 0.0 8.000 23.846 to 120 0.0 0.0 0.0 W22L 4.31 0.0 0.0 8.000 0.0 Vel = 0.25 0.0 4.31 23.846 K Factor = 0.88 W23 0.0 1.049 IT 5.0 1.917 22.925 to 120 0.0 5.000 0.920 W23L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 23.846 K Factor = 0 W24L 4.31 2.635 0.0 8.000 23.845 to 120 0.0 0.0 0.0 W23L 4.31 0.0001 0.0 8.000 0.001 Vel = 0.25 0.0 4.31 23.846 KFactor= 0.88 W24 0.0 1.049 1 5.0 1.917 22.924 to 120 0.0 5.000 0.920 W24L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 23.845 K Factor = 0 W25L 4.31 2.635 0.0 8.000 23.844 to 120 0.0 0.0 0.0 W24L 4.31 0.0001 0.0 8.000 0.001 Vel = 0.25 0.0 4.31 23.845 K Factor = 0.88 W25 0.0 1.049 IT 5.0 1.917 22.924 to 120 0.0 5.000 0.920 W25L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 23.844 K Factor =0 W26L 4.31 2.635 0.0 8.000 23.843 to 120 0.0 0.0 0.0 W25L 4.31 0.0001 0.0 8.000 0.001 Vel = 0.25 0.0 4.31 23.844 K Factor = 0.88 W26 0.0 1.049 IT 5.0 1.917 22.923 to 120 0.0 5.000 0.920 W26L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 23.843 K Factor =0 W27L 4.31 2.635 0.0 8.000 23.843 to 120 0.0 0.0 0.0 W26L 4.31 0.0 0.0 8.000 0.0 Vel = 0.25 0.0 4.31 23.843 K Factor = 0.88 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 14 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W27 0.0 1.049 IT 5.0 1.917 22.922 to 120 0.0 5.000 0.920 W27L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 23.843 K Factor 0 W28L 4.31 2.635 0.0 8.000 23.842 to 120 0.0 0.0 0.0 W27L 4.31 0.0001 0.0 8.000 0.001 Vel = 0.25 0.0 4.31 23.843 K Factor = 0.88 W28 0.0 1.049 iT 5.0 1.917 22.922 to 120 0.0 5.000 0.920 W28L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 23.842 K Factor =0 204 4.31 2.635 iT 16.474 28.250 23.838 to 120 0.0 16.474 0.0 W28L 4.31 0.0001 0.0 44.724 0.004 Vel = 0.25 0.0 4.31 23.842 K Factor = 0.88 204 289.26 4.26 0.0 12.000 23.838 to 120 0.0 0.0 0.0 205 289.26 0.0198 0.0 12.000 0.238 Vel = 6.51 0.0 289.26 24.076 K Factor = 58.95 105 285.30 4.26 0.0 12.000 24.079 to 120 0.0 0.0 0.0 106 285.3 0.0193 0.0 12.000 0.232 Vel = 6.42 0.0 285.30 24.311 K Factor = 57.86 W29L 2.11 2.635 iT 16.474 36.250 24.078 to 120 0.0 16.474 0.0 105 2.11 0.0 0.0 52.724 0.001 Vel = 0.12 0.0 2.11 24.079 K Factor = 0.43 W29 0.0 1.049 iT 5.0 1.917 23.158 to 120 0.0 5.000 0.920 W29L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 24.078 K Factor = 0 W30L 2.11 2.635 0.0 8.000 24.078 to 120 0.0 0.0 0.0 W29L 2.11 0.0 0.0 8.000 0.0 Vel = 0.12 0.0 2.11 24.078 K Factor = 0.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 15 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Ref. Qa Dia. "C" Fitting or Pipe Ftng's Pt Pt Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W30 0.0 1.049 IT 5.0 1.917 23.158 to 120 0.0 5.000 0.920 W30L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 24.078 K Factor = 0 W31 2.11 2.635 0.0 8.000 24.078 to 120 0.0 0.0 0.0 W30L 2.11 0.0 0.0 8.000 0.0 Vel = 0.12 0.0 2.11 24.078 K Factor= 0.43 W31 0.0 1.049 iT 5.0 1.917 23.157 to 120 0.0 5.000 0.920 W31 0.0 0.0001 0.0 6.917 0.001 Vel =0 0.0 0.0 24.078 K Factor = 0 W32L 2.11 2.635 0.0 8.000 24.078 to 120 0.0 0.0 0.0 W31 2.11 0.0 0.0 8.000 0.0 Vel= 0.12 0.0 2.11 24.078 K Factor = 0.43 W32 0.0 1.049 iT 5.0 1.917 23.157 to 120 0.0 5.000 0.920 W32L 0.0 0.0001 0.0 6.917 0.001 Vel = 0 0.0 0.0 24.078 K Factor = 0 W33L 2.11 2.635 0.0 8.000 24.077 to 120 0.0 0.0 0.0 W32L 2.11 0.0001 0.0 8.000 0.001 Vel= 0.12 0.0 2.11 24.078 K Factor = 0.43 W33 0.0 1.049 iT 5.0 1.917 23.157 to 120 0.0 5.000 0.920 W33L 0.0 0.0 0.0 6.917 0.0 Vel =0 - 0.0 0.0 24.077 K Factor = 0 W34L 2.11 2.635 0.0 8.000 24.077 to 120 0.0 0.0 0.0 W33L 2.11 0.0 0.0 8.000 0.0 Vel= 0.12 0.0 2.11 24.077 KFactor= 0.43 W34 0.0 1.049 iT 5.0 1.917 23.157 to 120 0.0 5.000 0.920 W34L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 24.077 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 16 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn W35L 2.11 2.635 0.0 8.000 24.077 to 120 0.0 0.0 0.0 W34L 2.11 0.0 0.0 8.000 0.0 Vel = 0.12 0.0 2.11 24.077 K Factor = 0.43 W35 0.0 1.049 iT 5.0 1.917 23.157 to 120 0.0 5.000 0.920 W35L 0.0 0.0 0.0 6.917 0.0 Vel = 0 0.0 0.0 24.077 K Factor = 0 205 2.11 2.635 1 16.474 28.250 24.076 to 120 0.0 16.474 0.0 W35L 2.11 0.0 0.0 44.724 0.001 Vel = 0.12 0.0 2.11 24.077 K Factor= 0.43 205 287.16 4.26 0.0 12.000 24.076 to 120 0.0 0.0 0.0 206 287.16 0.0195 0.0 12.000 0.234 Vel = 6.46 0.0 287.16 24.310 KFactor= 58.24 106 286.06 4.26 0.0 12.000 24.311 to 120 0.0 0.0 0.0 107 286.06 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.06 24.544 K Factor= 57.74 206 0.77 2.635 2T 32.948 112.500 24.310 to 120 0.0 32.948 0.0 106 0.77 0.0 0.0 145.448 0.001 Vel = 0.05 0.0 0.77 24.311 KFactor= 0.16 206 286.39 4.26 0.0 12.000 24.310 to 120 0.0 0.0 0.0 207 286.39 0.0195 0.0 12.000 0.234 Vel = 6.45 0.0 286.39 24.544 KFactor= 57.81 107 286.22 4.26 0.0 12.000 24.544 to 120 0.0 0.0 0.0 108 286.22 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.22 24.777 K Factor= 57.50 207 0.15 2.635 2T 32.948 112.500 24.544 to 120 0.0 32.948 0.0 107 0.15 0.0 0.0 145.448 0.0 - Vel = 0.01 0.0 0.15 24.544 KFactor= 0.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 17 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 207 286.24 4.26 0.0 12.000 24.544 to 120 0.0 0.0 0.0 208 286.24 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.24 24.777 KFactor= 57.51 108 286.23 4.26 0.0 12.000 24.777 to 120 0.0 0.0 0.0 109 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 25.010 K Factor = 57.23 208 0.01 2.635 2T 32.948 112.500 24.777 to 120 0.0 32.948 0.0 108 0.01 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.01 24.777 K Factor = 0 - 208 286.23 4.26 0.0 12.000 24.777 to 120 0.0 0.0 0.0 209 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 25.010 K Factor = 57.23 109 286.23 4.26 0.0 12.000 25.010 to 120 0.0 0.0 0.0 110 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 25.243 K Factor = 56.97 209 0.0 2.635 21 32.948 112.500 25.010 to 120 0.0 32.948 0.0 109 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 25.010 K Factor = 0 209 286.23 4.26 0.0 12.000 25.010 to 120 0.0 0.0 0.0 210286.23 0.0194 0.0 12.000 0.233 Vel= 6.44 0.0 286.23 25.243 K Factor = 56.97 110 286.23 4.26 0.0 12.000 25.243 to 120 0.0 0.0 0.0 111 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 25.476 K Factor = 56.71 210 0.0 2.635 2T 32.948 112.500 25.243 to 120 0.0 32.948 0.0 110 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 25:243 K Factor = 0 Computer Programs by Hydratec inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 18 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 210 286.23 4.26 0.0 12.000 25.243 to 120 0.0 0.0 0.0 211 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 25.476 KFactor= 56.71 111 286.23 4.26 0.0 12.000 25.476 to 120 0.0 0.0 0.0 112 286.23 0.0194 0.0 12.000 0.233 VeI= 6.44 0.0 286.23 25.709 K Factor= 56.45 211 0.0 2.635 2T 32.948 112.500 25.476 to 120 0.0 32.948 0.0 111 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 25.476 K Factor = 0 211 286.23 4.26 0.0 12.000 25.476 to 120 0.0 0.0 0.0 212 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 25.709 K Factor= 56.45 112 286.23 4.26 0.0 12.000 25.709 to 120 0.0 0.0 0.0 113 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 25.942 K Factor= 56.20 212 0.0 2.635 21 32.948 112.500 25.709 to 120 0.0 32.948 0.0 112 0.0 0.0 0.0 145.448 0.0 Vel0 0.0 0.0 25.709 K Factor =0 212 286.23 4.26 0.0 12.000 25.709 to 120 0.0 0.0 0.0 213 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 25.942 KFactor= 56.20 113 286.23 4.26 0.0 12.000 25.942 to 120 0.0 0.0 0.0 114 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 26.175 K Factor= 55.95 213 0.0 2.635 21 32.948 112.500 25.942 to 120 0.0 32.948 0.0 113 0.0 0.0 0.0 145.448 0.0 Vel = 0 0.0 0.0 25.942 K Factor =0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 19 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'IC" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 213 286.23 4.26 0.0 12.000 25.942 to 120 0.0 0.0 0.0 214 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 26.175 KFactor= 55.95 114 286.23 4.26 0.0 12.333 26.175 to 120 0.0 0.0 0.0 115 286.23 0.0195 0.0 12.333 0.240 Vel= 6.44 0.0 286.23 26.415 K Factor = 55.69 214 0.0 2.635 2T 32.948 112.500 26.175 to 120 0.0 32.948 0.0 114 0.0 0.0 0.0 145.448 0.0 Vet = 0 0.0 0.0 26.175 K Factor =0 214 286.23 4.26 0.0 12.333 26.175 to 120 0.0 0.0 0.0 215 286.23 0.0195 0.0 12.333 0.240 Vel= 6.44 0.0 286.23 26.415 KFactor= 55.69 115 286.23 4.26 0.0 12.000 26.415 to 120 0.0 0.0 0.0 116 286.23 0.0194 0.0 12.000 0.233 Vel= 6.44 0.0 286.23 26.648 K Factor = 55.45 215 0.0 1.61 2T 16.0 112.500 26.415 to 120 0.0 16.000 0.0 115 0.0 0.0 0.0 128.500 0.0 Vel = 0 0.0 0.0 26.415 K Factor =0 215 286.23 4.26 0.0 12.000 26.415 to 120 0.0 0.0 0.0 216 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 26.648 K Factor = 55.45 116 286.23 4.26 0.0 12.000 26.648 to 120 0.0 0.0 0.0 117 286.23 0.0194 0.0 12.000 0.233 Vel= 6.44 0.0 286.23 26.881 K Factor = 55.21 216 0.0 1.61 2T 16.0 112.500 26.648 to 120 0.0 16.000 0.0 116 0.0 0.0 0.0 128.500 0.0 Vet = 0 0.0 0.0 26.648 K Factor = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 20 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 216 286.23 4.26 0.0 12.000 26.648 to 120 0.0 0.0 0.0 217 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 26.881 K Factor = 55.21 117 286.23 4.26 0.0 12.000 26.881 to 120 0.0 0.0 0.0 118 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 27.114 KFactor= 54.97 217 0.0 1.61 2T 16.0 112.500 26.881 to 120 0.0 16.000 0.0 117 0.0 0.0 0.0 128.500 0.0 Vel = 0 0.0 0.0 26.881 K Factor 0 217 286.23 4.26 0.0 12.000 26.881 to 120 0.0 0.0 0.0 218 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 27.114 KFactor= 54.97 118 286.23 4.26 0.0 12.000 27.114 to 120 0.0 0.0 0.0 119 286.23 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.23 27.347 K Factor = 54.73 218 0.0 1.61 2T 16.0 112.500 27.114 to 120 0.0 16.000 0.0 118 0.0 0.0 0.0 128.500 0.0 Vel =0 0.0 0.0 27.114 K Factor =0 218 286.22 4.26 0.0 12.000 27.114 to 120 0.0 0.0 0.0 219 286.22 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.22 27.347 KFactor= 54.73 119 286.26 4.26 0.0 12.000 27.347 to 120 0.0 0.0 0.0 120 286.26 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.26 - 27.580 K Factor = 54.51 219 0.03 1.61 2T 16.0 112.500 27.347 to 120 0.0 16.000 0.0 119 0.03 0.0 0.0 128.500 0.0 Vel = 0 0.0 0.03 27.347 K Factor = 0.01 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 21 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 219 286.19 4.26 0.0 12.000 27.347 to 120 0.0 0.0 0.0 220 286.19 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.19 27.580 K Factor = 54.50 120 286.36 4.26 0.0 12.000 27.580 to 120 0.0 0.0 0.0 121 286.36 0.0195 0.0 12.000 0.234 Vel = 6.45 0.0 286.36 27.814 K Factor = 54.30 220 0.10 1.61 2T 16.0 112.500 27.580 to 120 0.0 16.000 0.0 120 0.1 0.0 0.0 128.500 0.0 Vel = 0.02 0.0 0.10 27.580 K Factor = 0.02 220 286.10 4.26 0.0 12.000 27.580 to 120 0.0 0.0 0.0 221 286.1 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 286.10 27.813 K Factor= 54.25 121 286.58 4.26 0.0 12.000 27.814 to 120 0.0 0.0 0.0 122 286.58 0.0194 0.0 12.000 0.233 Vel = 6.45 0.0 286.58 28.047 KFactor= 54.11 221 0.22 1.61 2T 16.0 112.500 27.813 to 120 0.0 16.000 0.0 121 0.22 0.0 0.0 128.500 0.001 Vel = 0.03 0.0 0.22 27.814 KFactor= 0.04 221 285.88 4.26 0.0 12.000 27.813 to 120 0.0 0.0 0.0 222 285.88 0.0194 0.0 12.000 0.233 Vel = 6.44 0.0 285.88 28.046 K Factor = 53.98 122 286.99 4.26 0.0 12.000 28.047 to 120 0.0 0.0 0.0 123 286.99 0.0196 0.0 12.000 0.235 Vel = 6.46 0.0 286.99 28.282 K Factor = 53.96 222 0.41 1.61 21 16.0 112.500 28.046 to 120 0.0 16.000 0.0 122 0.41 0.0 0.0 128.500 0.001 Vel = 0.06 0.0 0.41 28.047 K Factor = 0.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 22 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 222 285.46 4.26 0.0 12.000 28.046 to 120 0.0 0.0 0.0 223 285.46 0.0193 0.0 12.000 0.232 Vel = 6.43 0.0 285.46 28.278 K Factor= 53.68 123 287.66 4.26 0.0 12.000 28.282 to 120 0.0 0.0 0.0 124 287.66 0.0196 0.0 12.000 0.235 Vel = 6.48 0.0 287.66 28.517 K Factor= 53.87 223 0.67 1.61 2T 16.0 112.500 28.278 to 120 0.0 16.000 0.0 123 0.67 0.0 0.0 128.500 0.004 Vel = 0.11 0.0 0.67 28.282 K Factor= 0.13 223 284.80 4.26 0.0 12.000 28.278 to 120 0.0 0.0 0.0 224 284.8 0.0192 0.0 12.000 0.231 Vel = 6.41 0.0 284.80 28.509 K Factor= 53.34 124 288.66 4.26 0.0 12.000 28.517 to 120 0.0 0.0 0.0 125 288.66 0.0198 0.0 12.000 0.237 Vel = 6.50 0.0 - 288.66 28.754 K Factor= 53.83 224 1.00 1.61 2T 16.0 112.500 28.509 to 120 0.0 16.000 0.0 124 1.0 0.0001 0.0 128.500 0.008 Vel = 0.16 0.0 1.00 28.517 KFactor= 0.19 224 283.79 4.26 0.0 12.000 28.509 to 120 0.0 0.0 0.0 225 283.79 0.0191 0.0 12.000 0.229 Vel = 6.39 0.0 283.79 28.738 K Factor= 52.94 125 290.08 4.26 0.0 12.000 28.754 to 120 0.0 0.0 0.0 126 290.08 0.0198 0.0 12.000 0.238 Vel = 6.53 0.0 290.08 28.992 K Factor= 53.87 225 1.42 1.61 2T 16.0 112.500 28.738 to 120 0.0 16.000 0.0 125 1.42 0.0001 0.0 128.500 0.016 Vel = 0.22 0.0 1.42 28.754 K Factor = 0.26 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 23 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 225 282.38 4.26 0.0 12.000 28.738 to 120 0.0 0.0 0.0 226 282.38 0.0189 0.0 12.000 0.227 Vel = 6.36 0.0 282.38 28.965 K Factor= 52.47 126 291.99 4.26 0.0 10.167 28.992 to 120 0.0 0.0 0.0 127 291.99 0.0203 0.0 10.167 0.206 Vel = 6.57 0.0 291.99 29.198 KFactor= 54.04 226 1.92 1.61 2T 16.0 112.500 28.965 to 120 0.0 16.000 0.0 126 1.92 0.0002 0.0 128.500 0.027 Vel = 0.30 0.0 1.92 28.992 K Factor= 0.36 226 280.46 4.26 0.0 10.167 28.965 to 120 0.0 0.0 0.0 227 280.46 0.0188 0.0 10.167 0.191 Vel = 6.31 0.0 280.46 29.156 K Factor = 51.94 127 294.42 4.26 11 9.217 9.167 29.198 to 120 0.0 9.217 0.0 128 294.42 0.0205 0.0 18.384 0.376 Vel = 6.63 0.0 294.42 29.574 KFactor= 54.14 227 2.42 1.61 2T 16.0 112.500 29.156 to 120 0.0 16.000 0.0 127 2.42 0.0003 0.0 128.500 0.042 Vel = 0.38 0.0 2.42 29.198 K Factor = 0.45 227 278.04 4.26 11 9.217 9.167 29.156 to 120 0.0 9.217 0.0 228 278.04 0.0184 0.0 18.384 0.338 Vel = 6.26 0.0 278.04 29.494 K Factor= 51.20 128 294.42 4.26 iT 26.334 49.833 29.574 to 120 0.0 26.334 0.0 328 294.42 0.0205 0.0 76.167 1.558 Vel = 6.63 0.0 294.42 31.132 KFactor= 52.77 228 278.04 4.26 1 26.334 62.667 29.494 to 120 0.0 26.334 0.0 328 278.04 0.0184 0.0 89.001 1.638 Vel = 6.26 328 294.41 6.357 11 12.573 3.000 31.132 to 120 0.0 12.573 0.0 R-T 572.45 0.0100 0.0 15.573 0.156 Vel = 5.79 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams COSCO Fire Protection, Inc. Page 24 TARGET Warehouse- Carlsbad Date 8-20-09 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn R-T 0.0 6.357 lAla 33.948 21.417 31.288 to 120 0.0 33.948 9.276 R-B 572.45 0.0100 0.0 55.365 0.551 Vel = 5.79 R-B 100.00 6.16 1 17.215 14.000 41.115 Qa= 100 to 140 0.0 17.215 1.732 UI 672.45 0.0118 0.0 31.215 0.368 VeI= 7.24 Ui 0.0 6.09 2F 21.583 60.000 43.215 to 150 1M 18.5 90.957 6.280 U2 672.45 0.0110 1G 4.625 150.957 1.653 Vel= 7.41 iT 46.249 U2 0.0 7.98 1M 24.162 197.000 51.148 to 150 0.0 24.162 1.299 BF1 672.45 0.0029 0.0 221.162 0.650 Vel = 4.31 BF1 0.0 8.27 0.0 8.000 53.097 to 140 0.0 0.0 8.000 * Fixed loss = 8 BF2 672.45 0.0028 0.0 8.000 0.022 Vel = 4.02 BF2 400.00 7.98 2M 48.325 4.000 61.119 Qa=400 to 150 0.0 48.325 0.0 U3 1072.45 0.0070 0.0 52.325 0.365 Vel = 6.88 U3 0.0 7.98 IM 24.162 46.500 61.484 to 150 iT 52.855 83.057 0.0 SOR 1072.45 0.0070 1G 6.041 129.557 0.902 Vel = 6.88 0.0 1072.45 62.386 K Factor = 135.78 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087