HomeMy WebLinkAbout6231 YARROW DR; ; FA090051; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA090051 Job Address: 6231 YARROW DR Permit Type: FALARM Parcel No: 2130502000 Lot #: 0 Reference No.: Status: ISSUED Applied 11/17/2009 Approved: 11/17/2009 Issued: 11/17/2009 PC #: Inspector: Project Title: TARGET TWO FIRE ALARM INSPECTIONS © $65/EA Applicant: Owner: CHECKPOINT RIF III YARROW DRIVE II LLC 6640 SHADY OAK RD EDEN PRAIRIE, MN 11620 WILSHIRE BLVD #300 LOS ANGELES CA 800-457-6298 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 chec4palflg ip Checkpoint Systems, Inc. November 12, 2009 Attn: Anne Marie Bland Fire and Life Safety Consulting 4380 Carmel Drive Carlsbad, CA 92010 Project: Target #1029 6231 Yarrow Dr Ste C, D & E Carlsbad, CA 92008 Dear Ms. Bland, Enclosed you will find four sets of revised fire submittal plans, specification sheets, amp calculations, sequence of operations, and riser diagrams for the above project. The drawings have been revised to show the following changes: We will not be providing power to the duct smoke detectors or associated RTS. They will instead be powered by their respective RTU. It was discovered that new fire shutters provided by others must be tied into the fire system; this is now shown on the plans. Notes added to sheet FA- 1 stating there is an existing sprinkler system that is being monitored and that there is an existing smoke detector above the panel. Riser diagram, battery calculations, symbol schedule, wiring schematic, and sequence of operations have all been revised to reflect the changes. If there are any questions or concerns, please contact me by telephone at (800) 274-7802, or e-mail me at <andrew.kempski@checkpt.com>. Be sure to reference the project listed above in your correspondence. Sincer 'Iv, Andrew ~;Mpslki Designer II Corporate Office Distribution Center 8180 Upland Circle 6500 Carlson Drive Chanhassen, MN 55317 OD Listed Eden Prarie, MN 55346 (952) 227-5853 • Fax (952) 227-5854 Central Station (952) 227-5350 • Fax (952) 227-5809 TARGET #1029 FIRE ALARM SYSTEM SPECIFICATIONS CARLSBAD, CA This document and the accompanying written materials are the exclusive property of Checkpoint Systems, Inc. Possession of this document or any written material does not convey any right to reproduce, disclose its contents, or to produce, use, or sell anything it may describe. Reproduction, disclosure, or use without specific prior written authorization of Checkpoint is strictly forbidden. @L Underwriters Laboratories Inc. ® Northbrook, IL San Jose, CA Melville, NY Applicant ID No: 528621-001 Service Center No I Expires: 31-MAR-2010 A not-for-profit organization dedicated to public safety and committed to quality service CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From-.MINNEAPOLIS, MN Alarm Service Company: (528621-001) Service Center: (528621-001) TARGET ALARM CENTER TARGET ALARM CENTER 3701 WAYZATA BLVD 3701 WAYZATA BLVD MINNEAPOLIS MN 55416 MINNEAPOLIS MN 55416 The Alarm Service Company is Listed In the following Certificate Service Categories: File - Vol No. CCN Listing Category S7236 -1. UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31-MAR-2010 *** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" 2008 UL Form CS-CC ; - .f-. • , ;• ' • . :. •, - : - - - ___,__L: k..' ... ' -t'i - - L ' Intrusion Systems I 09412G Control Panel D9412G Control Panel Security Systems Digital communicator with phone line monitor (loop or ground start) Multiple telephone numbers, primary and duplicate paths with main and alternate destinations All reports within each of four route groups are programmable Optional dual phone line switcher monitors two phone lines Optional network interface module for two-way communication over Ethernet networks Automatic test and status reports Time windows for arming and open or close report suppression Programmable answering machine work-around for remote programming on shared phone lines Up to 238 RF points The G Series D9412G Control Panel provides an integrated solution fcr Access Control, Security, and Fire Alarm system applications. The co:ir01 panel can monitor alarm points for intruder or fire aIrms while operating user command centers and other outpJts. The control panel includes a communicator that reports events to selected PSTN or IP network destinations through four programmable route groups. The D9412G Control Panel provides eight on-board points and up to 238 Jff-Dard points. It provides up to 128 relays, and u to eight access control doors. Grant access from a Wiegand style card reader connected to: a D9210B Access Control Module, a Reques-to-enter or Request-to-exit input, or a keypad. Functions Programmable Outputs 2A alarm powerat12VDC 1.4 A auxiliary power at 12VDC Four alarm output patterns Programmable bell test Programmable bell shut-off timer The D9412G Control Panel provides up to 246 individually idnii±Ied points. Each point accommodates normally open (NO) and or normally closed (NC) devices with end-of-line (EOL resistor supervision. Each point is programmable for fire, fire supervisory, or burglary applications. Syst rn Response 31 custom point indexes, including fire supervisory Selectable point response time Cross point compatibility Fire alarm verification Fire inspector's local test Watch mode Scheduled events (skeds) arm, disarm, bypass and uribypass points, control relays, control authority levels, control door access and more Security ycu can rely on. :I.1j 2 I D9412G Control Panel User Interface Supervises up to eight command centers (up to 32 Un- supervised command centers can be used) Custom command center text Full function command menu including custom functions Each user has authority by area and 16-character name 14 custom authority levels control user's authority to change, add, delete passcodes or access control credentials, disarm, bypass points, and initiate system tests Adjustable brightness or volume for the keypad display or sounder Note: At least one keypad per system is recommended. Area Configurations Area programming offers a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master/associate). User Passcodes User passcodes contain three to six digits. Each user is assigned one of 14 customized authority levels in each area. Passcodes can be restricted to operate only during certain times. User names can contain up to 16 characters. The user name can be viewed, printed, reported to a central station in Modem lila2 Communications format or retrieved with Remote Programming (RPS) software. Communications The D9412G has four route groups. It can sort reports by priority and transmit reports to four route groups each of which has a programmable primary and backup destination. The D9412G is compatible with the D6600 NetCom Communications System using a DX4020 Network Interface Module. It has programmable anti-replay anti-substitution when using a DX4020. The Modem lila2 Communications Format, available with Bosch receivers, adds reporting capabilities such as: Individual point numbers and text Opening or closing reports by area number Remote programming attempts Diagnostic reports Security and Fire Detection The D9412G Control Panel provides eight on-board points, and up to 238 additional off-board points (depending on model and expansion interfaces). Points can be individually programmed and used to monitor all types of burglar alarm, fire alarm, and supervision devices. Event Log The event log stores up to 1,000 local and transmitted events. The event log includes time, date and event, with area, point and user number. You can view the event log from select keypads or remotely retrieve event information using RPS. With the printer interface module installed, you can use up to three on-site parallel printers. Use a local printer to provide a record of openings and closings without extra communications costs. RPS operators can retrieve events periodically using one phone call, rather than receiving several calls each day. When the event log reaches a programmed threshold of stored events, it can send a report to a receiver. Access events that can be stored, viewed or printed include: Access granted No entry Request-to-enter Request-to-exit Access Control Custom door strike, point shunt and auto disarming response by area Logging options for: Access Granted, No Entry, Request- to-exit, and Request-to-enter 14 panel-wide access levels with both manual and scheduled control Scheduled Events (Skeds) The internal clock and calendar help the control panel to execute individually scheduled events (skeds). Skeds perform a specific function such as arm or disarm, relay control, or point bypassing. 40 scheduled events with up to 26 different functions 16 open or closing windows Eight user windows Day-of-week, date-of-year, or holiday only schedules Four holiday schedules of 366 days each (leap year) Fire Test When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. Use a passcode at the keypad to activate Fire Test Mode. The keypad and annunciator show all testing data. An automatic sensor reset feature saves time; you do not need to reset the sensors manually. At the end of test, the keypad shows the number of untested points. D9412G Control Panel 13 Programming, Diagnostics and Controls Bells D440 Bell 12 V 15 cm (6 in.) Users can program all system functions on-site with a D52(X) D441 Bell 24 V 15 cm (6 in.) Programmer, or remotely through RPS. A programmable / D442 Bell 12 V, 25.4 cm (10 in.) system pcode prevents unauthor d remote D443 Bell 24 V, 25.4 cm (10 in. programming. The panels accommodate up to four separate telephone Programming Remote Programming Software (RPS) numbers for primary, alternate and backup receivers for D5200 Series Programmers automatic test reports. Modules C900TTL-E Dialer Capture Module When resetting alarms, arming or disarming a combination D125B Dual Class B Initiating Module fire/burglary and/or access control system, the user is 0127 Reversing Relay Module identified by name and number. D129 Class A Initiating Module D130 Auxiliary Relay Module Parts Included D136 Plug-in Relay 0185 Reverse Polarity Signaling Module D9412G Components Quantity 0192C Notification Appliance Circuit Module D9412G Board 1 0192G Notification Appliance Circuit Module Mounting Skirt 1 D8121A Derived Channel S.T.U. Five Zone Faceplate with D9412G Label 1 (Non-UL) Certifications and Approvals 08122 Derived Channel S.T.U. Five Zone (UL) D8125MUX Multiplex Bus Interface UL Standards UL365, Police Station Burglar Alarm Units and D8125 POPEX Point Expander Systems UL464, Audible Signal Appliances D81280 OctoPOPIT Eight Point Expander UL609, Local Burglar Alarm Units and Systems D8129 Octo-relay Module UL864 Controls units for Fire-Protective Signaling D9127 Series POPIT Modules Systems - Including Central Station, Remote D9131 Printer and Parallel Interface Module Station and Proprietary D9210B Series Access Control Interface UL985, Household Fire Warning System Units Modules UL1023, Household Burglar-alarm System Units 0S7432 Eight-input Remote Module UL1076, Proprietary Burglar alarm Units and Systems DS7457i Series Single Zone Multiplex Input UL1610, Central-station Burglar-alarm Units Modules UL1635, Digital Alarm Communicator System DS7460i Two-input Module Units 0S7461 i Single-input Multiplex Module Approvals FCC: AJ9MLU-46532-AL-E DS7465i Input and Output Module Factory Mutual DX4010i RS-232 Serial Interface Module CSFM: DX4020 Network Interface Module 7165-0801:123, Control Units - Non-high Rise rvm4c Remote Video Module 7170-0801:175, Control Units - High Rise Installation/Configuration Notes Compatible Products Keypads 01260 Series Keypads 0720 Series Keypads 01255 Series Keypads D1256 Fire Command Center 01257 Remote Fire Alarm Annunciator D279A Independent Zone Control 4 D9412G Control Panel Detectors Blue Line Detectors DS150i Series Request-to-exit Detectors DS160 Series High Performance Request-to-ecit Detectors D601 Fixed Temperature Rate-of-rise Heat Detector -' D602 Fixed Temperature Rate-of-rise Heat Detector D603 Electronic Fixed Temperature Rate-ofrise Heat Detector 0604 Electronic Fixed Temperature Rate-of-rise Heat Detector 0605 Electronic Fixed Temperature Rate-of-rise Heat Detector DS308EA Quad PIR Intrusion Detector DS415i, DS415iDC, and DS435i Single-beam Indoor Photoelectric Detectors DS416 Single Beam Photoelectric Detector DS420 Series Dual Beam Indoor and Outdoor Photoelectric Detectors DS433u Single Beam Indoor Photoelectric Detector DS720i Long Range TriTech PIR Detector (10.525 GHz) DS794Z Long Range PIR Detector DS820i and DS835i Series TriTech PIR Detectors 0S825 and DS840 Series TriTech PIR Detectors D5860 Series TriTech PIR and Microwave Detector 4 1D5915 Recess Mount PIR Detector DS918X and D5928X Ceiling-mount PIR Detectors D5934 PIR Detector with Replaceable Mirrors D5935Z PIR Intrusion Detector D5936 Low Profile Panoramic PIR Detector DS937 Panoramic Detector D5938Z Panoramic PIR Detectors DS940 Series PIR Intrusion Detectors Detectcrs DS940P and DS940PT Series PIR Detec:c'rs (Continied) DS9400 Quad PIR Detector DS950 and 0S970 Series High-performance Detectors 0S9360 Panoramic TriTech Detector DS9370 Series Panoramic TriTech Detector 0D850 Series Outdoor TriTech Detectors MX250 Series Smoke Detectors MX775i Addressable PIR Detector MX794i Long Range Multiplex PIR Detector MX934i Addressable PIR Detector MX938i Addressable PIR Detector ZX776Z PIR Detector ZX794Z Long Range PIR Detector ZX835 TriTech Microwave/PIR Detector ZX935Z PIR Detector ZX938Z PIR Detector ZX970 PIR/Microwave Detector Magnetic All Bosch magnetic contacts, including reces se.d, Contacts terminal connection, miniature, overhead docr, and surface mount. D9412G Control Panel 1 5 Wireless D81251NV Wireless Interface Readers D8201/W Series Low-profile Readers 5;7f Products FA113 Keychain Remote Control D8203/W Series Mullion Proximity Readers FA116 Executive Programmer D8223 Prox Pro Reader FA202 Wireless Smoke Detector and Transmitter D8224 Mullion Reader FA203S Necklace Pendant Transmitter D8224-SP Switch Plate Reader (Single-button) D8225 Mini Mullion Reader FA203D Necklace Pendant Transmitter D8227 Insert Card Reader (Double-button) D8301/W Series Low-profile Proximity Readers FA204 Necklace Pendant Transmitter D8302 Vandal-resistant Reader FA205S Belt Clip/Loop Transmitter D8303/W Series Mullion Proximity Readers (Single-button) D8304/W Series Extended Range Proximity FA205D Belt Clip/Loop Transmitter Readers (Double-button) WP612 Series Waterproof Pass-through FA206DS FIR Transmitter Readers FA206i FIR Transmitter WP644 Series Waterproof Pass-through FA209 Billtrap Transmitter Readers FA210 Universal Transmitter (Off-white) SAFECOM 5C2104 Series Slave Communicators FA21OW Universal Wide Gap Transmitter with Radio SC3100 Series Data Transfer Radio Internal Reed Switch (Off-white) Communicators Communicators FA216L Low Temperature Transmitter SC4000 Series Full Data Transfer Radio FA216H High Temperature Transmitter Communicator FA2233 Water-resistant Pendant Technical Specifications (White Single-button) FA223D Water-resistant Pendant Enclosures D8103 Universal (Black Double-button) D8108A Attack-Resistant FA250 High-power Universal Transmitter D8109 Fire FA400 Remote Receiver I FA404R Transmitter Receiver SDI Bus A (+): 9 VDC FA416R Transmitter Receiver 4572 m (15,000 ft) FA570 High Power Indoor Repeater SDI Bus B (-): 9 VDC FA575 High Power Indoor/Outdoor Repeater 4572 m (15,000 ft) Telephone Connection: • 2 TelCo lines D928 Dual Phone Line module required for 2 phone lines I.iui I Relative Humidity: 5%-85% at +30°C (+66°F), non- condensing Temperature (Operating): 0°C to +50°C (+32°F to +122°F) Areas: 8 Card Readers (Doors): 8 Credentials (Tokens): 996 Custom Functions: 16 Relays: 128 Events: Up to 1,000 Hardware Addresses: 246 Passcode Users: 249, plus 1 service passcode Parallel Printers: 3 6 I D9412G Control Panel Points: 246 (8 on board up to 238 off board) Programmable Relay Outputs: 131 RF Points 238 SKEDs: 40 eli Ll-If't Current Draw (Minimum): 200 mA Current Draw (Maximum): 500 mA Output (Alarm): 2 A at 12 VDC Output (Auxiliary, Continuous 1.4 A at 10.2 VDC to 13.9 VDC Power, and Switched Auxiliary combined): Voltage (Operating): 12 VDC Voltage (AC): 16.5 VAC 40 VA plug-in transformer (D1640) Voltage (DC): Up to 2 12 VDC, 7 Ah sealed lead acid rechargeable batteries Up to 2 12 VDC, 18 Ah sealed lead acid rechargeable batteries rde D9412G Control Panel D9412G D9412G Attack-Resistant Kit D9412G-A 09412G Fire and Burglar Kit 09412G-B D9412G Commercial Burglar Kit 09412G-C Hardware Accessories D101 Lock and Key Set D101 Works with standard and optional enclosures such as the D2203 and D8103. 0110 Tamper Switch 0110 Screw-on tamper switch that fits all enclosures. Shipped in packages of two. D122 Dual Battery Harness 0122 Harness with circuit breaker. Connects two batteries to a compatible control panel D122L Dual Battery Harness with Long Leads D122L Color-coded harness with circuit breaker and leads measuring 89 cm (35 in.). Connects 12 V batteries to compatible control panels. D126 Standby Battery (12V,,7 Ah) D126 Sealed lead-acid standby and auxiliary rechargeable power supply. D137 Mounting Bracket D137 0138 Mounting Bracket Right Angle D138 D928 Dual Phone Line Switcher D928 Ordering Information D1218 Battery (12V,18Ah) D1218 01224 Battery (12 V, 24 Ah) D1224 D1238 Battery (12 V, 38 Ah) 01238 01240 Battery (12 V, 4 Ah) D1240 D1640 Transformer D1640 08103 Enclosure D8103 Steel enclosure measuring 41 cm 41 cm 9 c (16 in. x 16 in. x 3.5 in.). 08108A Attack Resistant Enclosure D8108A 08109 Fire Enclosure 08109 09002-5 Mounting Skirt 09002-5 D136 Plug-In Relay D136 Software Options RPS D5500C-LPT Kit - 05500C-LPT RPS D5500C-USB Kit D5500C-USB Americas: Europe Middle East. Africa Bosch Security Systems Bosch Security Systems By. 130 Pennton Parkway P.O.Box 80002 Fairport New York. 14450, USA 5600 JB Eindhoven, The Netherlands Phone:+1 585 223 4060 Phone:+31 (0) 40 27 83955 +1 800 289 0096 Fax+31 (0) 40 27 86668 secur4.saies@us.bosch.com emea.securitysystems@bosch.com http://www.bo'schse curity us hftp://www.boschsecuHty.com Data subject to change without notice I Printed in USA I 4988148003en-01 16. Sep 2005 Asia-Pacific: Bosch Security Systems Pte Ltd 38C Jalan Pemirnpin Singapore 577180 Phone:+65 6319 3450 Fax:+65 63193499 apr.securitysystems@bosch.com http://www.boschsecurity.com BOSCH D1256, D1257 Fire Command Center, Fire Annunciator Specifications Features Compatible with the D9124, D9412G, 09412, D9112, D7412G, D7412 and 07212 Attractive low profile fire annunciators D1256 provides system control with easy to use function keys D1257 can be remotely installed in public access areas Built-in multi-tone sounder Easy to read vacuum fluorescent display Displays complete system status in English format Programmable custom text for each point Local system test display Molded red ABS plastic construction Description Radionics' D1256 Fire Command Center and D1257 Fire Alarm Annunciator are four-wire serial devices used with the Radionics' 09124 Addressable 24 VDC Fire Alarm Control! Communicator and the D9124, D9412G, 09412, 09112, 07412G, 07412 and 07212 Control/Communicators. One 01256 is included with the D9124 panel, which can be accessed through the slide door on the front of the enclosure. Both annunciators provide English text displays of system events with highly visible blue vacuum fluorescent displays. A built-in sounder alerts building personnel to system alarms and troubles and guides responding agencies to the annunciator location. Both units are molded in durable red plastic and have low profile enclosures. The wording "Fire Alarm Annunciator" is clearly printed on the faceplate of the 01257. This allows inspectors, service technicians and responding fire agencies to identify the annunciator. The D1256 Fire Command Center is a full-function system controller and annunciator. Four special one-touch function keys provide user-friendly control over the system. The function keys allow the user to silence the audible alarm output, silence the trouble sounder, reset the annunciator display and reset system detectors. Four additional navigational keys allow access to other programmed system functions. The D1257 Fire Alarm Annunciator provides remote annunciation capabilities without system control. Similar in appearance to a 01256 Fire Command Center, yet the 01257 Fire Alarm Annunciator lacks function keys. This makes system control functions inaccessible to unauthorized persons. Thus, the 01257 can be placed in locations where the public may have access to it. Two navigational keys allow the user to step forward or backward through a list of system events. 0 radionics Fire Command Center and Fire Annunciator Application The 01256 can be mounted in secure areas for use as both a system controller and annunciator. The 01257 Remote Fire Annunciator is typically installed in building entrances and areas with unrestricted access. Near exterior doors in hotel or business lobbies are ideal locations. This allows a responding agency, or persons evacuating the building to quickly identify the type and location of the emergency from outside the building without being in danger. Both devices have a built-in sounder that allows them to be installed in locations not in general view. Audible tones alert personnel to fire system events and assist fire fighters in locating the annunciator. Installation The 01256 and 01257 system annunciators connect to the fire control/communicator through standard four-wire cable. Shielded cable may sometimes be required where excessive EMI is a problem. The field wiring connects to a four-wire harness supplied with the unit. This harness plugs into a four-pin connector on the circuit board through the back of the 01256 or 01257. Each unit has three mounting holes in the base that allow secure, correct positioning during installation. Do not install the 01256 or 01257 in direct sunlight. This damages the module components and makes the display less visible. Install, test and maintain these devices according to their Installation Guides, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the devices to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained. A member of the Bosch Group Operational Data The D1256 and D1257 operate through the Serial Device Interface buss of the control/communicators. The D1256 and Dl 257 receive serial data and power through a four-wire cable. Both devices continually show the status of the fire alarm system. Changes in the normal panel condition such as alarm or trouble events are displayed in alphanumeric English text and the appropriate sounder response tone emitted. Resetting the display and sounder can only be accomplished at the D1256 Fire Command Center by authorized persons. Specifications D1256/D1257 Specifications Operating Voltage Nominal 12 voc (supplied by control/communicator) Operating Current 104 mA mm.; 206 mA max. Wiring Four conductors supply: Serial data, +12 VDC and panel common Display 16-character vacuum fluorescent Operating Temperature +32°F to 122°F (0°C to +50°C) Non-condensing Relative 5% to 85% at 86°F (30°C) Humidity Base Dimensions (Lx W x D) 8.3 in. x 4.5 in. 0.8 in. (21 cm x 11.4 cm x 2 cm) Wire Information Four-Conductor from Panel 01256 or D1257 Wiring Harness 12 VDC 12 VDC (Red) Data-Out Data-In (Yellow) Data-In Data-Out (Green) Common Common (Black) Listings and Approvals UL Listed CSFM Listed FM Approved Ordering Information Model Number Description D1256 Fire Command Center D1257 Remote Fire Alarm Annunciator 054B Brass Faceplate 054C Stainless Steel Faceplate D55 Desk Stand D56 Conduit Backbox Specifications The contractor shall furnish and install, where indicated on the plans, Radionics D1256 Fire Command Center and D1257 Remote Fire Alarm Annunciator. Each device shall have a 16 character vacuum fluorescent display and show all fire system events. Alarms shall be prioritized ahead of other system events and displayed in sequence. The D1257 shall have no on board system control function keys. A built-in sounder shall indicate events with distinct tones for fire alarm and system trouble. The D1256 and D1257 shall connect to the fire control/communicator through a four-wire cable. The D1256 and 1257 shall be constructed of high impact red plastic. The D1257 shall have the text "Fire Alarm Annunciator" clearly printed in bold letters to the right of the event display. The D9124, with the D91 12LTB, D91121311 and D7212131, have a 500 event non-volatile event memory log. The D9124 with the D9112LTB-EX or D9412GLTB, 9000/7000 Series panels have a 1000 event non-volatile memory log. All system events are displayed on system annunciators, printed locally or retrieved from off premises via the Remote Account Manager (RAM) software package. ISO 9002 e CERTIFICATE NO. A5137 © 2002 Radionics, a division of Detection Systems, Inc. 75-06926-000-D 2/02 P0 Box 80012, Salinas, CA 93912-0012 USA Specifications D1256, D1257 Customer Service: (800) 538-5807 L643 Page 2 of 2 Intrusion Systems I D9127 Series POPIT Modules D9127 Series POPIT Modules Provides point identification of initiating devices Supervises wiring to devices for circuit integrity Expands the number of points in the system Compact size Terminal connections for reliability Multiplex technology Low installation costs The D9127 Series POPIT Modules includes the D9127T (with magnetic tamper switch) and the D9 117U (without tamper. They are used with a D8125 Addressable Expansion Module whn there is a need to expand a compatible control panel beyond its standard number of on-board initiating zones or points. Future system expansion is very economical as D912 Series POPITs can be added anywhere along the two-wire data expansion loop from the D8125 module. Both modules include proven technology that combines zone and point supervision with individual device addressing on one pair of wires. Screw terminals provide reliable connections for the data expansion loop and supervised sensor loop wiring. Install a 33 kU end-of-line resistor at the farthest point on the loop for proper supervision. The units are small and easily installed in standard outlet boxes, above false ceilings, closets, or other accessible locations. Parts Included Quant. Component 1 POPIT module 1 33 kO EOL resistor 1 Magnet (D9127T only) 1 Hardware pack 1 Literature pack Certifications and Approvals Listings and UL AMCX: Central Station Alarm Units (UL1610) Approvals: UL AOTX: Local Alarm Units (UL464) UL APAW: Police Station Alarm Units (UL365) UL APOU: Proprietary Alarm Units (UL 1076) UL NBSX: Household Burglar Alarm System Units (UL 1023) UL IJOJZ: System Control Units (UL864) UL UTOU: Control Units and Accessories - Hoisehold System Type (UL985) CSFM 7167-1615: 100, 7165-1615: 113, 7165- 1615: 119, 7170-1615: 144, and 7170-1615: 145 Factory Mutual Research Security you can rely on. BOSCH 2 I 09127 Series POPIT Modules Installation/Configuration Notes Compatibility Information Control Panels D7212, D721281, D7212G, D7212G72, D7412, D7412G, D7412GV2, D9112, D9112B1, D9124, D9412, D9412G, D9412GV2 Module D8125 Note: The D8125 Multiplex Zone Expander is required. The D9127 modules are wired it parallel on the D8125 data loop. Number of POPIT Modules per Control Panel D7212G, D7212GV2 32 D9127 POPITs D7212131 40 D9127 POPITs D7212, D7412, D7412G, D7412GV2 67 D9127 POPITs POPIT to Sensor Loops The number of detection devices each sensor loop can supervise is limited only by the resistance on the loop. Resistance on each sensor loop must be less than 100 0 not including the end-of-line (EOL) resistor. Certain UL and National Fire Protection Association (NFPA) applications can limit the number of detection devices. Consult the appropriate UL or NFPA standards. Terminate each POPIT sensor loop with the 33 kfl EOL resistor included with each POPIT. Use a twisted-pair wire (six twists per foot) in all POPIT installations for both the data expansion loop wiring and the POPIT sensor loops. Run wires away from AC sources to prevent AC induction. D9124 119 D9127 POPITs D9112B1 126 D9127 POPITs D9112, D9412, D9412G, D9412GV2 238 D9127 POPITs Wiring Considerations D8125 to POPIT Loops Use one two-wire data expansion loop or distribute the POPITs on up to three loops. The maximum lengths shcwn in the following table are for all data expansion loops combined connected to the same POPEX module. Wire Size Maximum Length of all Data Expansion Loops Combined 22 AWG (0.8 mm) 1800 ft (549 m) 20 AWG 0.0 mm) 2890 ft (881 m) 18 AWG (1.2 mm) 4600 ft (1402 m) 16 AWG (1.5 mm) 7320 ft (2231 m) 14 AWG 0.8 mm) 11650 ft (3551 m) Setting DIP switches on the POPIT modules assigns them to point numbers. The switch setting on each POPIT assigns it a point number, regardless of its physical location. 1 Color: Off white Dimensions: 8.1 cm x 3.8 cm x 2.4 cm (3.2 in. xl.5 in. xo.9in.) Material: UL Listed fire-resistant I Relative Humidity: Up to 86% non-condensing Temperature (operating): +32°F to +122°F (0°C to +50°C) I Current Draw Idle: 0.5 mA per module In alarm: 0.8 mA per module Resistance: Maximum increase in resistance on the POPIT loop is 1000 0. Maximum resistance between the D8125 module and each POPIT is 90 0 Voltage (operating): 12 VDC nominal supplied by control panel Resistance: Maximum resistance on the sensor loop is 1000. Response Time 1 sec approximately D9127T POPIT with Tamper Switch D9127T D9127U POPIT without Tamper Switch D9127U Americas: Europe, Middle East. Africa: Bosch Security Systems Bosch Security Systems BY. 130 Perinton Parkway P.O. Box 80002 Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Phone:+1 585 223 4060 Phone:+31 (0) 40 27 83955 Fmc+1 800 289 0096 - Fax:+31 (0) 40 2786668 security.sales@us.bosch.com - emeasecuritysystems@bosch.com httpJ/www.boschsecurity.us http://www.boschsecurity.com Data subject to change without notice I Printed in USA I F01 U004834en-01 13. Oct 200 Asia-Pacific: Bosch Security Systems Pte Ltd BOSCH 38C ialárr Pemimpin Singapore 577180 Phone:+65 6319 3450 Fax:+65 6319 3499 apr.securitysystems@bosch.com http://www.boschsecurity.com M AltronjX@ I AL400ULX(R) Power Supply/Chargers Rev. Overview These multi-agency approved multi-output power supply/chargers convert a 1 15VAC/60Hz input into one (1) Class 2 Rated 12VDC or 24VDC power limited output. AL400ULX AL400ULXR Grey enclosure. Red enclosure. Specifications 12VDC or 24VDC selectable output. 12VDC @ 4 amp or 24VDC @ 3 amp supply current. Class 2 Rated power limited output. Input 115VAC / 60Hz, 1.45 amp. Input fuse rated @ 3.5 amp/250V Filtered and electronically regulated output. Short circuit and thermal overload protection. Built-in charger for sealed lead acid or gel type batteries. Maximum charge current .7 amp. Automatic switch over to stand-by battery when AC fails (zero voltage drop). AC fail supervision (form "C" contacts). Low battery supervision (form "C" contacts). Battery presence supervision (form "C" contacts). AC input and DC output LED indicators. Enclosure: - Combination knockouts are 1/2" and 3/4" - Accommodates up to two (2) 12VDC/7A}I batteries. Product weight: - AL400ULX: 7.3 lbs. - AL400ULXR: 6.3 lbs. Shipping weight: - AL400ULX: 8.2 lbs. - AL400ULXR: 7.3 lbs. Agency Approvals UL 294 UL Listed for Access Control L System Units. UL 603 UL Listed Standard for Power Supplies for Use with Burglar- Alarm Systems. UL 1069 UL Listed Hospital Signaling and Nurse Call Equipment. UL 1481 UL Listed Standard for Safety for Fire Protective Signaling Systems. U CUL Listed - CSA Standard C22.2 L No.205-M 1983, Signal Equipment. MEA MEA - NYC Department of Approved Buildings Approved. CSFM - California State Fire Marshal Approved. FM - Factory Mutual Approved. APPROVth 3.25" RM l0.50 3.25" 1.00" L Enclosure Dimensions 13'H x 13.5"W x 3.5"D 40" 4.05" 4.85" 1.40" 3.25" 1.20" r—.—.—.—.- -±±±—.— . 1.20 1.40 S S S S S S S S S S S S S S S S S • S S S S S S S 0 0 0 0 0 0 0 0 0 00000 o0o0o0o0o 0000 00000 6.5625 Model DHIOOACDCLP 4-Wire Photoelectric Duct Smoke Detector with Low-Flow Technology Product Overview Air velocity rating from The System Sensor InnovairTM DH100ACDCLP is a 4-wire photoelectric air 100 to 4000 feet per minute duct smoke detector capable of sensing smoke in air velocities from 100 to (0.5 to 2032 rn/sec.) 4,000 feet per minute (0.5 to 20.32 mlsec). This Innovair features Low-Flow Patented interconnectabillity for multi- technology that enables duct smoke detection throughout a broad range of air- fan shutdown (up to ten air handlers) flow environments. Many difficult to solve HVAC applications occur in low air- Patented telescopic sampling tube flow duct applications where reliable smoke detection is critical. Innovair with Patented cover tamper trouble signal Low-Flow technology can detect smoke at air speed velocities of 100 feet per 24 VAC/DC or 120/240 VAC operation minute or greater, while continuing the same reliable performance to 4,000 feet High-Low voltage barrier per minute. The two available form C relay contacts provide reliable performance for the Equipped with two DPDT Form C relay management of fans, blowers and air conditioning systems. These HVAC contacts devices can be configured to prevent the spread of toxic smoke and fire gasses Built-in reset button through a protected area Outside mounting tabs The Innovair family is designed for simplified installation and easy mainte- Easy and quick mounting to round nance. The modular construction allows for easy cleaning and uncomplicated or rectangular ducts from 1'-12' field replacement of the UL recognized power and sensor boards. The patented (0.3-3.7 meters) wide cover missing feature insures the cover is securely tightened following routine Easy to clean cleaning and maintenance. The patented interconnectability feature allows mul- UL recognized field-replaceable tiple Innovairs to communicate with each other. In the event smoke is detected, power and sensor boards the Innovair will signal the remaining interconnected detectors to initiate their Remote test station option relays for smoke control. Remote sounder option WARNING: Duct smoke detectors have specific limitations. Transparent cover for convenient DUCT SMOKE DETECTORS ARE: visual inspection NOT a substitute for an open area smoke detector, UL 268A listed NOT a substitute for early warning detection, and 3-year warranty NOT a replacement for a building's regular fire detection system. U Refer to NFPA 72 and 90A for additional information about the proper application of duct smoke detectors. LISTED Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor Model DH100ACDCLP Series Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The detector shall operate at air veloci- ties of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 rn/sec.). The unit shall be capable of controlling up to ten (10) air handling systems when interconnected with other detectors. The detector shall be capable of providing a trou- ble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch or remote testing using the SSK451 Multi-Signaling Accessory or the RTS451KEY Remote Test Station. The unit shall be reset by local reset button or remote test station. The duct smoke detector housing shall incorporate an airtight smoke chamber in compliance with UL 268A, Standard for Smoke Detectors for Duct Applications. The housing shall be capable of mounting to either rectangular or round ducts without adapter brackets. An integral filter system shall be included to reduce dust and residue effects on detector and housing, thereby reducing maintenance and servicing. Sampling tubes shall either be telescoping or be easily installed by passing through the duct housing after the housing is mounted to the duct. The unit shall provide a spacial separation of no less than 1/4I (6.4 mm) and/or a physical barrier between the high and low voltage terminals. The enclosure shall meet all applicable NEC and NFPA standards regarding electrical junction boxes. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Wiring Guide System wiring diagram for 4-wire duct smoke detectors POWER INPUTS ACCEPT 24 VOC, 24 VAC 50-60 HZ, 120 VAC 50-60 HZ, OR 220/240 VAC 50-60 HZ. CONNECT POWER SOURCE TO APPROPRIATE TERMINALS OF EACH DETECTOR. AUX. CONTACT RATINGS iDA @30 VDC RESISTIVE iDA @250 VAC iDOmA MINIMUM @5 VDC NOT INTENDED FOR CONNECTION TO CONTROL PANELS. TROUBLE CONTACT RATING 2.0 A @ 30 VDC resistive -------------- AVAILABLE POWER INPUTS 9 10 A B C I 1 20, '24V' tVA, 220/240 VAC ALARM AUXILIARY CONTACTS FOR FAN SHUTDOWN, ETC. I 16 6 17 7 18 8 I "C20 I ALARM AUXILIARY CONTACTS SHOWN IN I i STANDBY. CONTACTS TRANSFER DURING I ALARM AS INDICATED BY THE ARROWS. I SUPERVISORY TROUBLE CONTACTS 14 3 I TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY. I CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS REMOVED OR WHEN TAMPER FEATURE TIMES OUT. OPEN I CONTACTS SIGNAL TROUBLE CONDITION TO PANEL -------------- AVAILABLE POWER INPUTS CONNECT POWER SOURCE 9 10 I A B C I TO APPROPRIATE TERMINALS OF EACH DETECTOR. SEE SPECIFICATIONS FOR ?24V9 INFORMATION. ADDITIONAL POWER SUPPLY tGVA? 220/240 VAC I ALARM AUXILIARY CONTACTS FOR FAN SHUTDOWN, ETC. I 16 6 17 7 18 B FOR WIRING OF AUXILIARY N3 2 C 2 OR DEVICES, REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS CONTACT MANUFACTURER. I ALARM AUXILIARY CONTACTS SHOWN IN I NOTE: THE SUPERVISORY RELAY NOW STANDBY. CONTACTS TRANSFER DURING I PROVIDES A FORM C CONTACT FOR ALARM AS INDICATED BY THE ARROWS. I CUSTOMIZED APPLICATIONS. FOR STANDARD APPLICATIONS, ONLY I SUPERVISORY TROUBLE CONTACTS THE N0 CONTACT IS USED L—------------- I L. ------------- UL LISTED 4-WIRE FIRST DETECTOR IN THE LOOP LAST DETECTOR IN THE LOOP CONTROL PANEL DH100ACDC DH100ACDC I EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER Specifications Size 14%' (37 cm.) Length 51/3" (14 cm.) Width 2%" (7 cm.) Depth Shipping Weight 3% lbs. (1.7 kg.) Operating Temperature Range 320 to 131°F (00 to 55°C) Storage Temperature Range —220 to +158°F (-300 to +70°C) Operating Humidity Range 10% to 93% relative humidity non-condensing Air Duct Velocity 100 to 4000 ft./min. (0.5 to 20.32 rn/sec.) TEMPORAL SELECT () -Q) ALARM SIGNAL ALARM SIGNAL SUPERVISORY SUPERVISORY SIGNAL CONTACT RESET -f3( RESET TEST ®. - TEST POWER (-) AUX. POWER H POWER () I - AUX. POWER ll - INTERCONNECT. -® INTERCONNECT- 551(451 SSK451 UNIT 1 FIELD INSTALLED JUMPER 2 INTERCONNECT * INTERCONNECT- DH100ACDCLP UNIT 2 Wiring diagram for the RTS451/RTS451KEY and interconnect feature Alarm Signal Q) Aux. Power + 19 I Sup. N. 0. Sup.COM —® - Aux. Power— RTS451/RTS451KEY (Red LED) Alarm - ( (Green LED) Power (-p1 ALARM SIGNAL (*) / AUX POWER I—I DUCT DETECTOR PA400 (OPTIONAL) DH100ACDCLP AUDIBLE ALERT ALARM SIGNAL 1.1 6 I1IIIIIIIIID AUX POWER I—I qo DUCT DETECTOR DH100ACDCLP Electrical Ratings - DH100ACDCLP (Includes Detector) Power supply voltage: Input capacitance: Reset voltage: Reset time (with RTS451): Reset time (by power down) Power up time: Alarm response time: Sensitivity Test: 20-29 VDC 270 pF max. 3.0 VDC mm. .03 to 0.3 sec. 0.6 sec. max. 34 sec. max. 2 to 17 sec. See detector label 24 VAC 50-60-Hz 270 pF max. 2.0 VAC mm. .03 to 0.3 sec. 0.6 sec. max. 34 sec. max. 2 to 17 sec. See detector label 120 VAC 50-60 Hz N/A 10 VAC mm. .03 to 0.3 sec. 0.6 sec. max. 34 sec. max. 2 to 17 sec. See detector label 220/240V N/A 20 VAC mm. .03 to 0.3 sec. 0.6 sec. max. 34 sec. max. 2 to 17 sec. See detector label Power Supply voltage 1 20- 29 VDC 24 VAC 50 - 60 Hz 120 VAC 50 - 60 Hz 220/240 VAC 50 CURRENT REQUIREMENTS (USING NO ACCESSORIES) Max. standby current 15 mA 35 mA RMS 25 mA RMS 15 mA RMS Max. alarm current 70 mA 125 mA RMS 35 niA RMS 25 mA RMS' d CONTACT RATINGS Alarm initiation contacts (SPST) 2.OA @ 30 VAC/DC (0.6 power factor) Alarm auxiliary contacts (DPDT) 10A @30 VDC IOA@25OVAC Note: Alarm auxiliary contacts must switch lOOmA minimum at 5VDC. Alarm auxiliary contacts shall not be connected to inititaing circuits of control panels. Use the alarm initiation contact for this purpose. Trouble contacts (SPOT) 2.OA @ 30 VDC (resistive) Wiring diagram for DH100ACDCLP to APA45I ACCESSORY CURRENT LOADS AT 24 VDC DEVICE STANDBY TROUBLE ALARM APA451 12.5mA Max. rila 30mA Max. PA400 OmA n/a 15mA Max. RA400Z OmA rVa lOmA Max. RTS451/RTS451KEY 12mA nia 7.5mA Max. SSK451 5mA Max. 9mA Max. 30mA Max. *NOTE: When a unit is powered at the 120VAC or 220/240VAC input, any combination of accessories may be used such that the given accessory loads are: 60 mA or less in the standby state; 110 mA or less In the alarm state. DH100ACDCLP Alarm Signal Aux. Power + Sup. N. 0. Sup. COM Aux. Power - APA451 Alarm Power Common Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered with the same, independent supply. Polarity must be maintained throughout the interconnect wiring. Connect terminal 12 on unit 1 to terminal 12 on unit 2 and so on. Similarly, connect terminal 1 on unit 1 to terminal 1 on unit 2 and so on. NOTE: Wiring diagram shown is for DH100ACDCLP 4-wire duct smoke detector system equipped without a control panel. NOTE: A trouble condition is indicated when the green LED is not illuminated. Wiring diagram for DH100ACDCLP to SSK451 and interconnect feature FIELD INSTALLED JUMPER FOR TEMPORAL PATTERN I COMMON!(3) I Reset Test Interconnect - Interconnect + Unit 1 12 DH100ACDCLP UNIT 2 Interconnect - Interconnect + 15123)7 Colt Note: I - I Please note that the magnetic coil supplied with the RTS451/RTS451KEY is not Field required when these accessories are used with the DH100 detectors. The function- Installed ality of the magnetic coil has been designed into the circuitry of the InnoVair duct Jumper smoke detectors. Wiring diagrams for optional accessories *NOTE: For RTS451 KEY only without a Control Panel. RTS451 does not have a terminal 6. NOTE: Wiring diagram shown is for DH100ACDCLP 4-wire duct smoke detector system equipped without a control panel. NOTE: A trouble condition is indicated when the green LED is not illuminated. Ordering Information Part No. Description DH100ACDCLP 4-wire photoelectric duct detector with low-flow technology A5069 Replacement photoelectric detector board A5064 Replacement 4-wire power board Accessories ST-1.5 Metal sampling tube duct widths 1-2' (0.3-0.6 m) ST-3 Metal sampling tube duct widths 2-4' (0.6-1.2 m) ST-5 Metal sampling tube duct widths 4-8' (12-2.4 m) ST-10 Metal sampling tube duct widths 8-12' (2.4-3.7 m) 180-71-00 Replacement telescoping sampling tube P48-55-00 Replacement end cap for 180-71-00 5SK451 Multi-Signaling accessory R1S451KEY Remote test station with key lock R1S451 Remote test station APA451 Remote annunciator with piezo alarm Accessories MOD400R Sensitivity test module RA400Z Remote annunciator alarm LED F36-09-11 Replacement air filters (two per package) M02-04-00 lest magnet P48-21-00 End cap for metal sampling tubes S08-39-01 Photo replacement screen PA400W Mini-Alert sounder PS24LOW Mini-Alert add-on strobe PS12/24SLENSW Wall-mount "SMOKE" lens System Sensor provides system flexibility with a variety of accessories, including two remote test stations, and several different means of visible and audible system annunciation. As with our duct detectors, Fll duct smoke detector accessories are UL listed. APA451 Piezo Annunciator (UL S4011) RTS45I Remote Test Station Mini-Alert Scunder Remote lest Station with Key (UL S2522) (UL S3593) (UL S2522) shown with PS24LOW add- on strobe (PS12/24SLENSW smoke lens option available) RA400Z Remote Annunciator (UL S2522) 00 00 00 © I0In1a5 o:L00 S IlVil I 'I l#I boo boo boo 00 II II boo 00 00 l'-'l lIl boo boo 00 lf'\l boo I F © © 000000000 0000000000 0000000000 0000000000 0000000000 0000000000 - 0000000000 = - 0000000000 0000000000 0000000000 ( © © SSK451 Multi-Signaling Accessory (UL 268A) SSK45I. Multi-Signaling Accessory (UL 268A) shown with PS24LOW add-on strobe (PS12/24SLENSW smoke lens option available) System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 Documents-on-Demand 800/736-772 x3 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.276500 Fx: 44.1403.276501 System Sensor in China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System Sensor in Singapore Ph: 65.273.2230 Fx: 65.273.2610 System Sensor - Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor - Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor - India Ph: 91.124.637.1770 x.2700 Fx: 91.124.637.3118 0 2002 System Sensor. The company reserves the right to change product specifications without notice. A05-1044-003.7/02.#980 RTS451KEY UL S2522 SSK451 with PS24LOW strobe and PSI2/24LENSW "SMOKE" lens PA400 with PS24LOW add-on strobe Models Available APA451 Piezo Annunciator RA400Z Remote Annunciator RTS451 Remote Test Station RTS45IKEY Remote Test Station with Key SSK451 Multi-Signaling Accessory PA400R Mini-Alert Sounder (red) PA400W Mini-Alert Sounder (white) PS24LO Mini-Alert Add-on Strobe (red) PS24LOW Mini-Alert Add-on Strobe (white) PSI2/24SLENSW Wall-Mount "SMOKE" Lens Product Overview APA45I UL S4011 System Sensor provides system flexibility with a variety of accessories, including three remote test devices and several different means of visible and audible system annunciation. Like System Sensor's duct detectors, all duct smoke detector accessories are UL listed. APA45I The APA451 provides a red alarm LED, with an audible l annunciation of an alarm signal, and a green power LED. It is intended for use in System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply 70 with NFPA 90A. _____1 75 RA400Z The RA400Z remote annunciator is designed for both conventional and intelligent applications. The red LED provides RTS452. UL S2522 visual indication of an alarm condition. RTS45I and RTS45IKEY The RTS451 and RTS451KEY are automatic fire detector accessories designed to test remotely locat- ed duct detectors. For 4-wire detectors, the RTS451KEY features . a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. - SSK451 The SSK451 multi-signaling accessory is designed for use with System Sensor 4-wire conventional duct smoke detectors. - kT It combines a horn feature with the key-activated test and reset functions. Green, amber and red LEDs provide visual indication / of power, trouble and alarm conditions, respectively. PA400R and PA400W The PA400 models are 90dBA pulsed SSK451 UL S2522 sounders for applications where a smaller notification device is required. The PS24LO and PS24LOW add-on strobes can be attached for visual alarm signaling. PS24LO and PS24LOW The PS24LO and PS24LOW strobes can be attached to the PA400 or SSK4S1 for visual alarm signaling. The PSI2/24SLENSW "SMOKE" lens is available to meet special code requirements in certain jurisdictions. t rg__~ I I LISTED PA400W UL S4011 APA45I. Specifications Voltage Regulated 24VDC Operating Voltage 16-33VDC Maximum Alarm Current 30mA Temperature Range -10°C to 38°C (14°F to 100°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18AWG Dimensions 4.6"H x 2.75"W x 1.5"D PA400 Specifications Voltage 12/24VDC Temperature Range -10°C to 60°C (14°F to 140°F) Wire Gauge 12 to 18AWG Dimensions 4.6" x 2.8" x 1.4" RA400Z Specifications Voltage Range Conventional System: 3.1 to 32VDC Intelligent System: 18 to 32VDC Maximum Alarm Current lOmA Dimensions 4.6" x 2.8" x 1.3" RTS451 Specifications Power Requirements Alarm LED: 2.8-32VDC, lOmA max. Total Current: 105mA max. Test Switch IOVA @ 32VDC Reset Switch 10VA @ 32VDC Alarm Response Time 40 seconds max. Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18AWG Dimensions 4.6"H x 2.75"W x 1.8"D P524L0 Specifications Voltage 24VDC Temperature Range 0°C to 49°C (32°F to 120°F) Wire Gauge 12 to 18AWG Dimensions 3.8" x 1.6" x 1.6" 5SK451 Specifications Voltage 24VDC Power Requirements Standby: 8mA Trouble: 16mA Alarm without strobe: 40mA Alarm with strobe: 65mA Sounder 87dBA at ten feet Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22AWG Dimensions 4.8"H x 4.7"W x 1.5"D RTS451KEY Specifications Power Requirements Power LED (Green): 14-35VDC, 12mA max. Alarm LED (Red): 2.8-32VDC, 7.5mA max. Total Current: 103mA maximum Alarm Response Time 40 seconds maximum Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18AWG Dimensions 4.6"H x 2.75"W x 1.8"D For the very latest product specifications, please visit the System Sensor web site at www.systemsensor.com. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5110 Ph: 800/SENSOR2 System Sensor Europe System Sensor In Singapore Fx: 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 www.systemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 System Sensor - Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor - Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor - India Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor - Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 © 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0375-000.06/04.#1291 LISTING No CATEGORY: LISTEE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM Ilk 1%M LISTING SERVICE 7165-1615:119 Page lof2 Fire Alarm Control Unit (Commercial)* Bosch Security Systems, 130 Perinton Parkway, Fairport, NY 14450 Contact: Frank Mioduszewski (585) 678-3368 Fax (585) 678-3263 Frank.skiC@us.bosch.com DESIGN: Models D7212B, D74123, D7412GV2, D9112B, D9412, D9412G and D9412GV2 fire alarm control units. Inherently power-limited; remote station, central station and local service. Refer to listee's data sheet for detailed product description and operational considerations. System components: D122 D125B D126 D127/D136 D928 D129 D130/D8130 D161/162 D192C/192D/D192G D268/269/279 D720/1255/1256/1257 D720R/1255R/D720W/D1 255W/Dl 260 *D1 255RB/*1 256RB/*1 257RB D8132 D1218 D8121 A/8122 D81 25/D8125MUX D9127T/D9127U D8128/81 28N8128C/D81 28D D8129 D9131 D1640 D8004/8103/8109/8108A D8109G/D8109H/D8109L D91 33TTL-E, DX4020 DS7432 DS7457iF/DS7461 i DS7460i DS7465i lCP-SDI-91 14 Dual Battery Hardness Powered Loop Interface Module 12V, 7Ah Rechargeable Battery Relay Dual Phone Line Switcher Module Initiating Circuit Module Relay Module/Release Module Phone Cord Circuit Supervision Modules Independent Zone Control Modules Command Centers Command Centers Command Centers Battery Charger Module Battery - 12V 18 Ah Subscriber Terminal Unit POPEX Module POPIT OctoPOPIT Module OctoRelay Module Parallel Printer Interface Class 2 Transformer Enclosures Enclosures Network Interface Module Mutiplex Expander Module Single Zone Multiplex Input Module 2-Zone Expander Input/Output Multiplex Module SDI Splitter/Isolator Module INSTALLATION: In accordance with the listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 06-19-09 bh Listing No. 7165-1615:119 Page 2 of 2 APPROVAL: Listed as fire alarm control units suitable for high rise application for use with separately listed compatible Applied American Technologies' Model EVAC-2101 voice evacuation/communication system (CSFM Listing No. 6911-1393:103), two way firefighter telephone system, initiating and indicating signal devices. Models D9127T and D9127U POPIT modules shall be used with four-wire smoke detectors only. Model EVAC-2101 and the FACP must be installed in the same room, not more than 20' apart. Wiring between the FACP and the EVAC-21 01 must be in conduit. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturers installation instruction manual for details. Authority having jurisdiction shall be consulted prior to installation. *Suitable for high-rise applications when used with the above separately listed voice evacuation systems. This control unit meets the requirements of UL Standard 864, 8th Edition. NOTE: 1. For Fire Alarm Verification Feature (delay of alarm sicinaling), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Burglary and other non-fire functions were not examined. Combined with 7170-1615:145 FORMERLY: 7165-0801:123, 7170-0801:175 *Rev. 06-19-09 bh This sting is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or -ecommendation of the item listed. This listing should not be used to verify correct operational requirements or installation ri:era. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 309 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTEC11ON OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-1335:100 Page 1 of 1 CATEGORY: Power Units LISTEE: Altronix, 140 - 58th Street, Bldg. A-3W, Brooklyn, NY 11220 Contract: Alan Forman (718) 567-8181 Fax (718) 567-9056 DESIGN: Models AL300ULX, AL300ULM, AL400UL, AL400ULX, AL400ULM, AL400UL3X, AL600UL3X, ALl 024ULM and ALl 024ULX power supply units. Model AL400ULX is identical to Model AL400UL except for a larger enclosure. Models AL400ULM is basically an AL400ULX with a MOM5 multi-output power module also typical of Models AL1024ULM and AL1024ULX respectively. Models AL300ULX and AL300ULM are designed to charge sealed lead acid type rechargeable batteries. Models AL400UL3X and AL600UL3X employ the triple output module ALX3B. Model Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 115 VAC input, 12 or 24 VDC output INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For fire alarm use, the standby batteries must provide 24 hours standby power during power loss. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units to provide power for door holders, door strikes or similar devices. NOTE: Not suitable for fire alarm indicating devices. Rev. 06-1 4-20031P1 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING No. 3240-1653:119 Page 1 of 2 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Duct smoke detector units, Models DH100P, DH100LP, DH100ACDCP, DH100ACDCLP, DH1 OOACDCLPX, DH1 OOACDCLWP, EDH1 OOLP, EDH1 OOACDCLP, DH1 OOACDCI, DI-1200P, DH200PL, DH200RP, DH200RPL, DI-1400, DH400ACDC, DH400ACDCP, DH400ACDCPX, DH400ACDCIR, DH400ACDCP5V, DH400ACDCI5V, DH400ACDCIHT, DH400REL, DI-1500, DH500ACDC, P270-10001 and P270-1 000P. Unit consists of a housing, relay, electrical components, sampling and exhaust tubes and a listed detector head. Series DI-1400, P270-1001 and P270-1000P are intended for use with Models 1451 DH (CSFM Listing No. 7271-1653:108) and 2451 (CSFM Listing No. 7272-1653:112) detector heads for open area protection which have been tested for duct applications. Model DH400ACDCIHT is intended for use with Model 1451 DHHT smoke detector (CSFM Listing No. 7271-1653:108) Series DH500 are intended for use with Models 1551 (CSFM Listing No. 7271-1653:105) and 2551 (CSFM Listing No. 7272-1653:106) detector heads for open areas that have been tested for duct applications. *Model DH1 OOACDCLWP has a NEMA 4 watertight housing that is to be installed where the ambient air temperature will not fall outside the range of 32 degrees Fahrenheit to 131 degrees Fahrenheit. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Model DH400ACDCIHT may be used with model DH4000E-1 (Hoffman Model A-1813126) enclosure for outdoor application. MARKING: Listee's name, model designation, air velocity rating and UL label. Page 2 of 2 3240-1653:119 APPROVAL: Listed as duct detector units when used with listee's separately listed compatible fire alarm control units. Models DH1 OOLP, EDH1 OOLP, DH1 OOACDCLP, DH1 OOACDCLPX, DH1 OOACDCLWP, DH200PL, DH200RPL and EDH100ACDCLP are suitable for use in ducts where air velocity varies between 100 and 4000 fpm. Models P270-10001 and P270-1000P are suitable for use in ducts where air velocity varies between 300 and 4000 fpm. Models DH100P, DH100ACDCP, DH100ACDCI, DH200P, DH200RP, DH400, DH400ACDC, DH400ACDCIR, DH400ACDCP5V, DH400ACDCI5V, DH400ACDCIHT, DH400REL, DH500, and DH500ACDC are suitable for use in ducts where air velocity varies between 500 and 4000 fpm. Also suitable for use as a stand-alone unit where permitted. NOTE: Formerly 3240-1209:137, 139 and 3240-1209:155 *Rev 7-09-2007 mt This ls1ing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/cr other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 305 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:110 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models RTS451 and RTS451 KEY remote test switches, and Model RTC remote test station kit. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as accessory devices for use with separately listed compatible duct smoke detectors. NOTE: Formerly 7300-0087:129, 7300-1209:129 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 309 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division M Altroni AL300ULX(R) Power Supply/Charger Rev. Overview These multi-agency approved single output power supply/chargers convert a 115VAC/60Hz input into one (1) Class 2 Rated 12VDC or 24VDC power limited outputs. AL300ULX AL300ULXR Grey enclosure. Red enclosure. Specifications 12VDC or 24VDC selectable output. 2.5 amp supply current. Class 2 Rated power limited output. Input 115VAC / 60Hz, 1.45 amp. Input fuse rated @ 3.5 amp/250V Filtered and electronically regulated output. Short circuit and thermal overload protection. Built-in charger for sealed lead acid or gel type batteries. Maximum charge current .7 amp. Automatic switch over to stand-by battery when AC fails (zero voltage drop). AC fail supervision (form "C" contacts). Low battery supervision (form "C" contacts). Battery presence supervision (form "C" contacts). AC input and DC output LED indicators. Enclosure: - Combination knockouts are 1/2" and 3/4" - Accommodates up to two (2) 12VDC/7AH batteries. Product weight: - AL300LJLX: 7.7 lbs. - AL300ULXR: 7.3 lbs. Shipping weight: - AL300ULX: 8.7 lbs. - AL300TJLXR: 8.3 lbs. Agency Approvals UL 294 UL Listed for Access Control ® I System Units. UL 603 UL Listed Standard for Power Supplies for Use with Burglar- Alarm Systems. UL 1069 UL Listed Hospital Signaling and Nurse Call Equipment. UL 1481 UL Listed Standard for Safety for Fire Protective Signaling Systems. U CUL Listed - CSA Standard C22.2 L No.205-M1983, Signal Equipment. MEA MEA - NYC Department of Approved Buildings Approved. CSFM - California State Fire Marshal Approved. 3.25" 1.1875" 0 3.25" Enclosure Dimensions 13.5"H x 13"W x 3.25"D TOP ONLY 1.1875" o .75" 1.5" 6.25" 11"11.75"12.5" 0 1.1875" 3.25" I I 1 1 I OOOCDOOOOO OOOCDOOOOO 00>00 5.5" -E 0000000000 00000 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-1335:100 Page 1 of 1 CATEGORY: Power Units 5;7f LISTEE: Altronix, 140- 58th Street, Bldg. A-3W, Brooklyn, NY 11220 Contract: Alan Forman (718) 567-8181 Fax (718) 567-9056 DESIGN: Models AL300ULX, AL300ULM, AL400UL, AL400ULX, AL400ULM, AL400UL3X, AL600UL3X, AL1024ULM and AL1024ULX power supply units. Model AL400ULX is identical to Model AL400UL except for a larger enclosure. Models AL400ULM is basically an AL400ULX with a MOM5 multi-output power module also typical of Models AL1024ULM and ALI024ULX respectively. Models AL300ULX and AL300ULM are designed to charge sealed lead acid type rechargeable batteries. Models AL400UL3X and AL600UL3X employ the triple output module ALX3B. Model Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 115 VAC input, 12 or 24 VDC output INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For fire alarm use, the standby batteries must provide 24 hours standby power during power loss. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units to provide power for door holders, door strikes or similar devices. NOTE: Not suitable for fire alarm indicating devices. Rev. 06-14-20031Pl This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR Smoke Detectors with Sounder and Relay Option System Sensor j3" sounder and relay smoke detectors apply the guiding principles of installation ease, intelligence, and instant inspection in a series of specialty conventional devices. Installation ease. Throughout the i3 series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options and provides ample space for pre-wiring the device. To complete the installation, the i3 detector plugs into its base with a simple Stop Drop 'N Lock action. Intelligence. To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms such as RF interference and dust accumulation. When connected to the 2W-MOD2 loop test/ maintenance module or an i3 Ready' panel, 2-wire il detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any il detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds. Instant inspection. The P line's red and green LEDs simplify local status indication during power-up, standby, alarm, maintenance and freeze trouble conditions. When in alarm, P sounder models generate an 85 dB temporal tone. If connected to the RRS-MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. Additionally, the RRS-MOD synchronizes the output of all i3 sounders to ensure a clear audible signal. Features .85 dB sounder Form C relay Isolated thermal sensor Plug-in design - base included In-line terminals Flexible mounting options Stop-Drop 'N Lock attachment to the base Removable cover and chamber Remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Dual color LEDs Agency Listings Should the application call for differentiating between a local and IVIEA MSFM a general alarm, the i line offers an isolated thermal model, which initiates a local alarm when smoke is detected, and a general alarm LISTED APPROVED approved approved when the thermal sensor is activated. S911 3015195 7272'1653-164 372•02•E 2133 (i Smoke Detector Specifications Operating Voltage Nominal: 12/24V non-polarized 2-wire: 8.5 V -35 V 4-wire: 10 V -35 V Maximum Ripple Voltage 30% of applied voltage (peak to peak) Standby Current 2-wire: 50 pA maximum average 4-wire: 50 pA maximum average Peak Standby Current 2-wire: 100 pA 4-wire: n/a Maximum Alarm Current 2-wire: 2WTR-B: 130 mA limited by control panel 2VVIA-B: 130 mA** 4-wire: 4WTA-B, 4WFR-B: 35 mA 4WTAR-B, 4W1TAR-B: 50 mA **Direct Power (Non-reverse Polarity): 130 mA limited by panel. Reverse Polarity Power: 30 mA for the 2WIA-B in alarm; 12 mA for all other 2WIA-B units on the loop. Add 25 mA for the RRS-MOD reversing relay alarm current. Alarm Contact Ratings 2-wire: n/a 4-wire: 0.5 A @ 30V AC/DC Form C Contact Ratings 2A @ 30V AC/DC SpecificationsPhysical 1 Operating Temperature Range 32°F-100° F (0°C-37.8° C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135° F (57.2° C) fixed Freeze Trouble 41°F (5'C) Sensitivity 2.50/o/ft. nominal Input Terminals 14-22 AWG Dimensions (including base) 5.3 inches (134 mm) diameter, 2.0 inches (51 mm) height Approximate Weight 7.1 oz. (200 grams) Sound Pressure Output 85 dBA (models 2WTA-B, 4WTA-B, 4WTAR-B, and 4WlTAR-13 only) Mounting 31/2-inch octagonal back box, 4-inch octagonal back box, Single gang back box, 4-inch square back box with a plaster ring, Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Power up Blink every Blink every 10 Initial LED 80 seconds 10 seconds seconds status indication Normal Blink every 5 off (standby) seconds Out of off Blink every 5 sensitivity seconds Freeze off Blink every 10 trouble seconds Alarm off Solid Condition Duration Initial LED 80 seconds status indication Smoke detector shall be a System Sensor i3 Series model number_______ listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a combination photoelectric/thermal equipped with a sounder (model 2WTA-B, 4VVTA-B), a Form C relay (model 2VVTR-B), a combination sounder/relay (model 4\NTAR-B) or an isolated thermal/sounder/relay (model 4W1TAR-B). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5% per foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power-up, normal standby, out of sensitivity, alarm, and freeze trouble conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. When used in conjunction with the RRS-MOD module, all i3 sounder models on a loop shall sound when one alarms, all shall be synchronized, and all sounders may be silenced from the panel. Ordering Information 2WTA-B Yes 2-wire 130 mA max. limited by control panel 2WTR-B Yes 2-wire 130 mA max. limited by control panel 4WIA-B Yes 4-wire 35 mA 4WTR-B Yes 4-wire 35 mA 4WJAR-B Yes 4-wire 50 mA 4W11AR-B Yes 4-wire 50 mA RRS-MOD Reversing relay/synchronization module 2W-MOD2 2-wire loop test/maintenance module SENS-RDR Sensitivity reader RI Removal/replacement tool A77-AB2 Retrofit adaoter bracket 02006 System Sensor 3825 Ohio Avenue. St. Charles, IL 60174 Product sipe,:ificadors subject to change without notice. Vsit systemsensorcom for SItI5R Phone: 800-SENSOR2. Fax: 630-377-6495 current product information, including the latest version of this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:164 Page I of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Irish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models 2WTA-B, 2WTR-B, 4WTA-B, 4WTR-B, 4WTAR-B and 4WITAR-B photoelectric smoke detectors. Units also employ a 1350 supplemental integral thermistor type heat sensor for use only as a supplement to the smoke detector. This thermal circuitry in NOT approved for use in lieu of required heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 8.5-35 Vdc - 2WTA-B, 2WTR-B 10-35 Vdc - 4WTA-B, 4WIR-B, 4WTAR-13, 4WITAR-13 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Intended for vertical wall surface or ceilings in open areas with an air velocity of 0 to 1000 fpm. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Models 2WTA-B, 4WIA-B, 4WTAR-B and 4WITAR-B only can generate a distinctive temporal code pattern fire alarm signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 1. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. 2. Formerly 7272-1209:224 06-20-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division f SYSTEM $ SENSOR® Multi-Voltage Conventional Relays System Sensor's multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features Multi-voltage operation Activation LEDs Easy and flexible installation Reliable and robust design Multipurpose field installations Multi-voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-1 OT/20T and R-1 4T/24T Removable front cover on steel enclosure for R-1 OUR-20E and R- 14/R-24E, which mount inside the enclosure LED viewing hole on top of the steel enclosure's cover Extra pair of wires for redundant power input on PR-3 Terminal strip field wiring connections, mounting track, and hardware The R-1 01, R-20T, R-1 4T, and the R-24T models are multi- voltage relays with terminal strip field wiring connections, mounting track, and hardware. The R-1 OT is a single FORM—C (SPDT) relay with a red activation LED, and the R-1 4T is a four-gang 1 FORM—C (SPDT) relay with four red activation LEDs. The R-20T is a single 2 FORM—C (DPDT) relay with a red activation LED, and the R-24T is a four-gang 2 FORM—C (DPDT) relay with four red activation LEDs. The R-i OE/R-20E and R-i 4E/R-24E are similar to the T-series track mount relays, but they are mounted into a steel enclosure. The enclosure has a removable front cover that provides easy access and an LED viewing hole on the top of the cover. PR-i IPR-2IPR-3 are epoxy encapsulated multi-voltage relays. They are single-pole double-throw relays that use a red LED as a visible indication of relay coil energization. PR-3 is identical to PR-2, except it has an extra pair of wires for redundant power input. Model EOLR-i is an epoxy encapsulated, single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. Agency Listings @ @ X MEA approved LISTED Multi-Voltage Conventional Relay Specifications Operating voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @24 VDC, 24VAC, 115 VAC, 230 VAC (R-1 OT/13-1 4T) 40 mA DC max. @24 VDC, 24VAC, 115 VAC, 230 VAC (R-201/R-24T) Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10% - 93% non-condensing Dimensions R-1 OT/R-20T: 2.51 x 3.35W x 1.21-I R-1 41/R-24T: 101 x 3.35W x 1.21-1 Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10A 120 VAC: 1/6 HP 230 VAC: 7 A Specifications: R-10E/R-14E/R-20E/R-24E Operating voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @24 VDC, 24VAC, 115 VAC, 230 VAC (R-IOE/R-14E) 40 mA DC max. @24 VDC, 24VAC, 115 VAC, 230 VAC (R-20E/R-24E) Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10% - 93% non-condensing Dimensions R-1 OUR-20E: 5.11 x 3.75W x 2.51-I R-14E/R-24E: ill x 5.3W x 2.51-1 Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10A 120 VAC: 1/6 HP 230 VAC: 7 A Operating voltage 18-35 VDC, 18-35 VAC, 120 VAC Operating Current 15 mA DC max. @24 VDC, 24VAC, 120 VAC Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10- 93% RH Wire Length 8 minimum Dimensions 0.871-I x 2.01"W x 1.421) Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive 30 VDC: 10 A resistive LIiT I3 Operating Voltage 10 to 40 VDC Operating Current 30 mA DC max. Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10- 93% RH Wire Length 8minimum Dimensions 0.911-lx 1.65Wx 1.221) Contact Ratings Specifications: EOLR-1 120 VAC: 10 A max. (resistive load) 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load) 30 VDC: 10 A max. (resistive load) Operating Voltage 9 to 40 VDC Operating Current 20 mA DC max. Operating Temperature -22°F to 140°F (-30°C to 60°C) Humidity Range 10- 93% RH Wire Length 8-minimum Contact Ratings 120 VAC: 0.5 A max. (resistive load) 30VDC: 3 A max. (resistive load) PR-1 EOLR-1 PR-3 R-1 OE & R-20E Enclosure PR-2 R-1 OT R-14T R-1 4E & R-24E Enclosure 02007 System 3825 Ohio AvenueS St. Charles, IL 60174 current product information, including the late tver ion ofthis data sheet SENSOR' Phone: 800-SENSOR2 . Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION M. OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:103 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles IL 60174 Contact: Irish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models listed below: MSOOM, M501M M500R, M5005, M500MB M500C, M500CH, M502M M500X A2143-00 SMB500 RMK400 MB500 CB500 EOLR-1 Monitor Modules Control Modules Control Modules Fault Isolator Module End-of-line Resistor Surface Mount Box Recessed Mounting Kit Module Panel Barrier Module End-of-Line Supervision Relay Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Model SMB500 surface mount box maybe used as an enclosure for the Model MSOOM monitor module, Models M500C or M500CH control module or Module M500X fault isolator module. Model A2143-00 end-of-line resistor is intended for use in the initiating circuit of the MSOOM and the indicating circuit of the M500C. Model RMK400 mounting kit is intended for use with separately listed compatible smoke detectors. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1209:104 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division FUNDAMENTALS OF FIRE ALARM SYSTEMS FA0CJ00S t 72-31 FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: Target . .1 Address: 6231 Yarrow Dr Ste CD.E Representative of protected property (name/phone): Authority having jurisdiction: City of Carlsbad Address/telephone number: /f35 Ifh.y ,4.,ie Q,-/'c bf, 4 Q20c'g' (7'o) (002 - Organization name /phone Representative name /phone Installer Advanced Alarms (909) 762-0555 Darius Brazaitis (909) 762-0555 Supplier Checkpoint Systems (800) 457-6298 Service organization Checkpoint Systems (800) 457-6298 Location of record (as-built) drawings: Checkpoint Systems Location of operation and maintenance manuals: Location of test reports: Checkpoint Security A contract for test and inspection in accordance with NFPA standard(s) Contract No(s): Effective date: Expiration date: System Software Operating system (executive) software revision level(s): (0 00 Site-specific software revision date: Revision completed by: Manufacturer Bosch Security (name) (firm) 1. Type(s) of System or Service _____NFPA 72, Chapter 6— Local If alarm is transmitted to location(s) off premises, list where received: X NFPA 72, Chapter 8—Remote Station Telephone numbers of the organization receiving alarm: Alarm: Checkpoint Systems (800) 457-6298 Supervisory: Checkpoint Systems (800) 457-6298 Trouble: Checkpoint Systems (800) 457-6298 If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8— Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: _____NFPA 72, Chapter 8—Central Station Prime contractor: Central station location: (NFPA 72, 1 of 4) FIGURE 4.5.2.1 Record of Completion. 2002 Edition Date: Signed: Orgamz 72-32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-way radio Digital alarm communicator Two-way radio Others Means of transmission of alarms to the public fire service communications center: (i) (h System location: NFPA 72, Chapter 9—Auxiliary Indicate type of connection: _______ Local energy _______ Shunt _______ Parallel telephone Location of telephone number for receipt of signals: Record of System Installation (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by _______ on , includes the devices shown in 5 and 6, and has been in service since jL.NFPA 72, Chapters (3 (2> & & a 6D 7 t 9 11 (circle all that apply) _ NFPA 70, National Electrical Code, Article 760 .JL.. Manufacturer's instructions Other (specify): Signed: Date: Organization: 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached - All operational features and functions of this system were tested by date and found to be operating properly in accordance with the requirements of: 2L NFPA 72, Chapters 19 ug U0 7 9 11 (circle all that apply) ..X NFPA 70, National Electrical Code, Article 760 .JL Manufacturer's instructions Other (specify): 4. Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity: 2 Style: 4 Class: B (NFPA 72, 2 of 4) FIGURE 4.5.2.1 Continued 2002 Edition FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 5. Alarm-Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5): Quantity: 16 Style: _A Class: (a) Manual stations Noncoded_________ Transmitters (b) Combination manual fire alarm and guard's tour coded stations Coded________ Addressable________ AUTOMATIC Coverage: Complete Partial Selective Nonrequired Smoke detectors 10 Ion Photo X Addressable_________ Duct detectors 6 Ion X Photo ________ Addressable__________ Heat detectors FT RR FT/RR RC Sprinkler waterfiow indicators: Transmitters________ Noncoded Coded The alarm verification feature is disabled X or enabled -, changed from - U) Other (list): - Addressable - Addressable________ seconds to seconds. 6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a)__ Coded stations (b)__ Noncoded stations (c) Compulsory guard's tour system comprised of ___________ transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. SPRINKLER SYSTEM Check if provided (a) Valve supervisory switches (b)Building temperature points Site water temperature points Site water supply level points Electric fire pump: (e)Fire pump power Fire pump running Phase reversal Engine-driven fire pump: Selector in auto position Engine or control panel trouble Fire pump running ENGINE-DRIVEN GENERATOR: Selector in auto position Control panel trouble Transfer switches (d)Engine running Other supervisory function(s) (specify): (NFPA 72, 3 of 4) FIGURE 4.5.2.1 Continued 2002 Edition 72-34 NATIONAL FIRE ALARM CODE 7. Annunciator(s) Number: 1 Type: VFD Location: NIE Entry 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6—Emergency Voice/Alarm Service Quantity of voice/alarm channels: ___________________ Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: Quantity and the class of notification appliance circuits connected to system (see NFPA 72, Table 6.7): Quantity: Style: Class: Types and quantities of notification appliances installed: Bells With Visible Speakers With Visible Horns With Visible Chimes With Visible Other: With Visible (I) Visible appliances without audible: 9. System Power Supplies Fire Alarm Control Panel: Nominal voltage: 16.5VAC Current rating: 1.4A Overcurrent protection: Type: Fuse Current rating: 1.4 A Location: Fire Panel Secondary (standby): Storage battery: X Amp-hour rating: 26 A.H. Calculated capacity to drive system, in hours: 24 Engine-driven generator dedicated to fire alarm system:________________________________________________________ Location of fuel storage: Emergency system used as backup to primary power supply: Emergency system described in NFPA 70, Article 700: 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: (signed) for• istalati on Contr ctor/supplier (title) (date) ( /2'/2 (signed) for alarm Krvi e co pany (title) ccL (date) ( )/ (signed) for central station (title) (date) Upon completion oft>9 system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (signed) representative of the authority having jurisdiction (title) (date) (NFPA 72,4 of 4) FIGURE 4.5.2.1 Continued 2002 Edition