HomeMy WebLinkAbout6231 YARROW DR; ; AS080079; PermitCity of Carlsbad Sprinkler Permit Permit No: AS080079 Job Address: 6231 YARROW DR Permit Type: SPRINK Parcel No: 2130502000 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 5/22/2008 Approved: 5/29/2008 Issued: 5/29/2008 I Inspector: Project Title: REXFORD INDUSTRIAL UNDERGROUND PIPING PLAN CHECK & INSPECTIONS Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 Owner: RIF III YARROW DRIVE II LLC 1160 WILSHIRE BLVD #300 LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 260 0 260 0 I rlsbad Municipal Water Dist t Potable Water Discharge Event Report Date: iL- \o Location: QAI '1t\V Reason for Discharge Event: 'ñc Type of Event: Dewateriñg Water Mains Note: Includes flow testing and flushing Dewatering Reservoirs Unscheduled Water Discharge Clear flow path of debris, surface contaminants and/or hazardous materials. Do not removenative vegetation. Erosion control, I.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity of discharge water. End Time Pre-Dechiorination Residual: Post-Dechlorination Residual: o) J (less than 0.1 mg/L) pH within limits of 6.0 and 9.0 7 Initial Estimated Discharge Flow: lbllbL Start Time Upon completion of dewatering, ensure that the flow path is free of all temporary erosion prevention materials. Upon completion of dewatering, ensure that any sediment or silted areas are cleared. Water Sampling Performed by: _____________________________________________ Comments: Submitted by: Reviewd by: (Name & Date) (Name & Date) - Flow Test Record Test Hydrant Location GM( çfj Hydrant ID No. Size Main_____________ Static .............1 j( Residual......... AtDPDIPressure Drop.. 1).....K factor for PDI 1 Flow Hydrant(s) Hydrant I location Hydrant 2 location Hydrant 3 location Hydrant 1 Pitot PSI GPM:V(ot7 Size of Orifice_______ Hydrant 2 Pitot PSI GPM: Size of Orifice_______ Hydrant 3 Pitot PSI GPM: Size of Orifice._______ Total:___________ (Qi) Calculated test and flow data - 0 x PD2 k =Q2 PDI*k Static: Desired Residual.......20 Pressure Drop (PD 2).. K factor PD 2: x divided by equals GPM at 20 psi residual Q PD2k PD1k Q2 Comments: Test conducted for: 0 Conducted by: . h DateA' ( c/b Time:(OZO Flow Test Record Formulas GPM-Flow 2 /2' 4" PSI GPM PSI GPM PSI GPM PSI GPM 170 16 670 1 430 16 1720 2 240 17 690 2 610 17 1770 3 290 18 710 3 740 18 1820 4 340 19 730 4 860 19 1870 5 380 20 750 5 960 20 1920 6 410 22 790 6 1050 22 2020 7 440 24 820 7 1140 24 2110 8 480 26 860 8 1220 26 2190 9 500 28 890 9 1290 28 2280 10 530 30 920 10 1360 30 2330 11 560 33 950 11 1430 32 2430 12 580 34 980 12 1490 34 2510 13 610 36 1010 13 1550 36 2580 14 630 38 1040 14 1610 38 2650 15 650 40 1060 15 1660 40 2720 K Factor Formula PD K PD K PD K PD K PD K 1= 1.0 21= 5.18 41= 7.43 61= 9.21 81= 10.73 2= 1.45 22= 5.31 42= 7.53 62= 9.29 82= 10.80 3= 1.81 23= 5.44 43= 7.62 63= 9.37 83= 10.87 4= 2.11 24= 5.56 44= 7.72 64= 9.45 84= 10.94 5= 2.39 25= 5.69 45= 7.81 65= 9.53 85= 11.01 6= 2.63 26= 5.81 46= 7.91 66= 9.61 86= 11.08 7= 2.86 27= 5.93 47= 8.00 67= 9.69 87= 11.15 8= 3.07 28= 6.05 48= 8.09 68= 9.76 88= 11.22 9= 3.28 29= 6.16 49= 8.18 69= 9.84 89= 11.29 10= 3.47 30= 6.28 50= 8.27 70= 9.92 90= 11.36 11= 3.65 31= 6.39 51= 8.36 71= 9.99 91= 11.43 12= 3.83 32= 6.50 52= 8.44 72= 10.07 92= 11.49 13= 4.00 33= 6.61 53= 8.53 73= 10.14 93= 11.56 14= 4.16 34= 6.71 54= 8.64 74= 10.22 94= 11.63 15= 4.32 35= 6.82 55= 8.71 75= 10.29 95= 11.69 16= 4.48 36= 6.93 56= 8.79 76= 10.37 96= 11.76 17= 4.72 37= 7.03 57= 8.88 77= 10.44 97= 11.83 18= 4.76 38= 7.13 58= 8.96 78= 10.51 98= 11.89 19= 4.90 39= 7.23 59= 9,04 79= 10.59 99= 11.96 20= 5.04 40= 7.33 60= 9.12 80= 10.66 100= 12.02 *PD = Pressure drop K = K factor WEST COAST FIRE PROTECTION 271 ROYMAR ROAD SUITE F OCEANSIDE,CA 92054 HYDRAULIC CALCULATIONS FOR 6231 & 6241 YARROW DECTOR CHECK PROOF CALCULATION FILE NUMBER: DATE: MAY 21, 2008 -DESIGN DATA- OCCUPANCY CLASSIFICATION: ORDINARY DENSITY: .2 gpm/sq. ft. AREA OF APPLICATION: 1500 sq. ft. COVERAGE PER SPRINKLER: 130 MAX NUMBER OF SPRINKLERS CALCULATED: 0 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 0.0 gpm TOTAL WATER REQUIRED (including hose): 1100.0 gpm AVAILABLE FLOW AND PRESSURE (@ TOR) : 850 gpm @ 84.6 psi REQUIRED WATER FLOW (@ TOR) : 850 GPM @ 20 PSI SPRINKLER ORIFICE SIZE: 1/2" NAME OF CONTRACTOR: WEST COAST FIRE PROTECTION DESIGN/LAYOUT BY: DAN AMATO AUTHORITY HAVING JURISDICTION: CITY OF CARLSBAD FIRE DEPT. RAW WATER FLOW TEST DATA S=124 R=118 @ 1060 **GPM REDUCED 10% FOR THIS CALC* CONTRACTOR CERTIFICATION NUMBER: C-16 763542 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 27081246 HRS SYSTEMS, INC. TUCKER, GA 30084 * SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF JOB TITLE: 6241 YARROW DUOBLE CHECK VALVE REPLACMENT WATER SUPPLYDATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 111.6 105.6 1060.0 105.2 1100.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 1100.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 850.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 0.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) BOR 20.0 HOSE STREAM 84.6 850.0 Ui 16.5 - - - - 87.0 - - - U2 12.0 - - - - 92.3 - - - BF1 18.0 - - - - 89.8 - - - BF2 18.0 - - - - 94.8 - - - U3 12.0 - - - - 97.9 - - - SOURCE 0.0 SOURCE 105.2 850.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF JOB TITLE: 6241 YARROW DUOBLE CHECK VALVE REPLACMENT PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -850.0 6.044 PL 10.00 PF 0.8 BOR 20.0 H.S. 84.6 850.0 9.5 140 FTG EB PE 1.5 Ui 16.5 0.0 87.0 0.0 0.020 TL 41.39 PV Pipe: 2 -850.0 6.090 PL 150.00 PF 3.3 Ui 16.5 0.0 87.0 0.0 9.4 150 FTG 2EG PE 1.9 U2 12.0 0.0 92.3 0.0 0.017 TL 197.79 PV Pipe: 3 -850.0 6.044 PL 6.00 PF 0.1 U2 12.0 0.0 92.3 0.0 9.5 140 FTG ---- PE -2.6 BF1 18.0 0.0 89.8 0.0 0.020 TL 6.00 PV Pipe: 4 FIXED PRESSURE LOSS DEVICE BF2 18.0 0.0 94.8 0.0 5.0 psi, 850.1 gpm BF1 18.0 0.0 89.8 0.0 Pipe: 5 -850.0 6.044 PL 6.00 PF 0.5 BF2 18.0 0.0 94.8 0.0 9.5 140 FTG B PE 2.6 U3 12.0 0.0 97.9 0.0 0.020 TL 24.31 PV Pipe: 6 -850.0 6.090 PL 53.00 PF 2.1 U3 12.0 0.0 97.9 0.0 9.4 150 FTG ETG PE 5.2 SOURCE 0.0 SRCE 105.2 (N/A) 0.017 TL 125.46 PV NOTES (HASS) Calculations were performed by the HASS 7.9 computer program under license no. 27081246 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.025 gpm and a maximum imbalance at any node of 0.076 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 9.5 ft/sec at pipe 3. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF JOB TITLE: 6241 YARROW DUOBLE CHECK VALVE REPLACMENT PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkViv BfyVlv GatVlv AlmChk DPVlv NPTee 6.044 13.77 29.50 8.85 31.46 9.83 2.95 27.53 27.53 29.50 6.090 14.28 30.61 9.18 32.65 10.20 3.06 28.57 28.57 30.61 NOTES (USER) All 0 C> SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF. JOB TITLE: 6241 YARROW DUOBLE CHECK VALVE REPLACMENT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 OD w KT r-I - SPINKLR SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF JOB TITLE: 6241 YARROW DtJOBLE CHECK VALVE REPLACMENT WATER SUPPLY CURVE 120+ *\\\\\\ 110+ \\\\\\\ \\\\\\ I * X-105.6 psi @ 1060 gpm I Flow Test Point 100+ 90+ P 80+ R I E I S H 5 70+ U I R I E I 60+ P I S I 50+ 40+ 30+ 20+ LEGEND I I, I X = Required Water Supply IT 105.17 psi 8 1100.0 gpm IT 10+ I, 0++-+---+----+-----+ ------+ --------+ --------+ ---------+ -----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) WEST COAST FIRE PROTECTION 271 ROYMAR ROAD SUITE F OCEANSIDE,CA 92054 HYDRAULIC CALCULATIONS FOR 6231 & 6241 YARROW DECTOR CHECK PROOF CALCULATION FILE NUMBER: DATE: MAY 21, 2008 -DESIGN DATA- OCCUPANCY CLASSIFICATION: ORDINARY DENSITY: .2 gpm/sq. ft. AREA OF APPLICATION: 1500 sq. ft. COVERAGE PER SPRINKLER: 130 MAX NUMBER OF SPRINKLERS CALCULATED: 0 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 0.0 gpm TOTAL WATER REQUIRED (including hose) : 1100.0 gpm AVAILABLE FLOW AND PRESSURE (@ TOR) : 850 gpm @ 84.6 psi REQUIRED WATER FLOW (@ TOR) : 850 GPM @ 20 PSI SPRINKLER ORIFICE SIZE: 1/2" NAME OF CONTRACTOR: WEST COAST FIRE PROTECTION DESIGN/LAYOUT BY: DAN AMATO AUTHORITY HAVING JURISDICTION: CITY OF CARLSBAD FIRE DEPT. RAW WATER FLOW TEST DATA S=124 R=118 @ 1060 **GPM REDUCED 10% FOR THIS CALC* CONTRACTOR CERTIFICATION NUMBER: C-16 763542 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 27081246 HRS SYSTEMS, INC. TUCKER, GA 30084 * SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF JOB TITLE: 6241 YARROW DUOBLE CHECK VALVE REPLACMENT WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 111.6 105.6 1060.0 105.2 1100.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 1100.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 850.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 0.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) BOR 20.0 HOSE STREAM 84.6 850.0 Ui 16.5 - - - - 87.0 - - - U2 12.0 - - - - 92.3 - - - BF1 18.0 - - - - 89.8 - - - BF2 18.0 - - - - 94.8 - - - U3 12.0 - - - - 97.9 - - - SOURCE 0.0 SOURCE 105.2 850.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF JOB TITLE: 6241 YARROW DUOBLE CHECK VALVE REPLACMENT PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -850.0 6.044 PL 10.00 PF 0.8 BOR 20.0 H.S. 84.6 850.0 9.5 140 FTG EB PE 1.5 Ui 16.5 0.0 87.0 0.0 0.020 TL 41.39 PV Pipe: 2 -850.0 6.090 PL 150.00 PF 3.3 Ui 16.5 0.0 87.0 0.0 9.4 150 FTG 2EG PE 1.9 U2 12.0 0.0 92.3 0.0 0.017 TL 197.79 PV Pipe: 3 -850.0 6.044 PL 6.00 PF 0.1 U2 12.0 0.0 92.3 0.0 9.5 140 FTG ---- PE -2.6 BF1 18.0 0.0 89.8 0.0 0.020 TL 6.00 PV Pipe: 4 FIXED PRESSURE LOSS DEVICE BF2 18.0 0.0 94.8 0.0 5.0 psi, 850.1 gpm BF1 18.0 0.0 89.8 0.0 Pipe: 5 -850.0 6.044 PL 6.00 PF 0.5 BF2 18.0 0.0 94.8 0.0 9.5 140 FTG E PE 2.6 U3 12.0 0.0 97.9 0.0 0.020 TL 24.31 PV Pipe: 6 -850.0 6.090 PL 53.00 PF 2.1 U3 12.0 0.0 97.9 0.0 9.4 150 FTG ETG PE 5.2 SOURCE 0.0 SRCE 105.2 (N/A) 0.017 TL 125.46 PV NOTES (HASS) Calculations were performed by the HASS 7.9 computer program under license no. 27081246 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.025 gpm and a maximum imbalance at any node of 0.076 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 9.5 ft/sec at pipe 3. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF JOB TITLE: 6241 YARROW DUOBLE CHECK VALVE REPLACMENT PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkViv BfyVlv GatVlv AlmChk DPVlv NPTee 6.044 13.77 29.50 8.85 31.46 9.83 2.95 27.53 27.53 29.50 6.090 14.28 30.61 9.18 32.65 10.20 3.06 28.57 28.57 30.61 NOTES (USER) Q Q 0 It 0 0 c'J 0 0 0 I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF JOB TITLE: 6241 YARROW DUOBLE CHECK VALVE REPLACMENT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c.'1 0 -1 QDr1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/21/2008 C:\HASS78\6231YARROW.SDF JOB TITLE: 6241 YARROW DUOBLE CHECK VALVE REPLACMENT WATER SUPPLY CURVE 120+ *\\\\\\ 110+ \\\\\\\ I \\\\\\ I * X-105.6 psi @ 1060 gpm I Flow Test Point 100+ 90+ P 80+ S R I E I S 5 70+ U R I B I 60+ P I S I I 50+ 40+ 30+ 20+ LEGEND I X = Required Water Supply I 105.17 psi @ 1100.0 gpm " 10+ I Pt I It II 0++-+---+----+-----+ ------+ --------+ --------+---------+-----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) SUBMITTAL SHEET APPLICATION Designed for installation on potable water lines in fire sprin- kler systems to protect against both backsiphonage and backpressure of polluted water into the potable water sup- ply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE FEATURES (unless otherwise noted, applies to sizes 4" thru 10") I-! Sizes: 0 4" U 6 U 8" 0 10" OPTIONS (Suffixes can be combined) U - with OS & Y gate valves (standard) U L - less shut-off valves (grooved body connections) U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U - with Cu ft/mm meter U G - with groove end gate valves U FG - with flanged inlet gate connection and grooved outlet gate connection U FS - with cast iron Wye type strainer (flanged only) U FSC - with epoxy coatedwye type strainer(flanged only) UBGVIC - with grooved end butterflyvalves U P1 - with Post Indicator Gate Valve (4"-10") ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U Valve setter (Model FLS or MJS or MJFS) U Gate valve tamper switch (OSY-40) U Flange by groove adapter(FLA) U QT-SET Quick Test Fitting Set U Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) ASSE®Listed 1048 CSA® Certified (4" & 6") AWWA Compliant C 510 UL® Classified C-UL® Classified FM®Approved Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California MATERIALS Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYL, NSF Listed Springs Stainless steel, 300 series _A_ Maximum working water pressur 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (FIaned) ANSI B16.1 Class 125 DIMENSIONS_(approximate) WEIGHT MODEL B B C C J LESS OS&Y A WITH GATE LESS GATE OS&Y OS&Y I P GATE GATE SIZE VALVES VALVES OPEN CLOSED VALVES VALVES mm in. 4 100 185/16 465 30 762 21 533 223/4 578 181/4 3 105 47.7 295 134 6 15011811/116 475 351121902 25 635 301/8 765 23 341 603[4 174 79 474 215 8 200 29 737 46 1168 347/16 845373/4 959 291/4 49j A13330 i[0 402 182.5 878 1399- 10 250 29 737 471/2 1207 347/16 845 453/4 1162 353/8 420 191 1076 489 iilur Page 1 of 2 FLOW CHARACTERISTICS MODEL 450DA 4" & 6" (STANDARD) FLOW RATES (lie) 25.2 50.5 75.7 46. El (5 15 Cq co 10 101 O IX 400 800 1200 a- FLOW RATES (GPM) MODEL 450DA 8" & 10" (STANDARD & METRIC) FLOW RATES (I/s) 63.1 126.2 189.3 252.4 104 i 0. 69 35 4000 V! 0. 0 1000 2000 FLOW RATES (GPM) *Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordancewith the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. W,UqNS VALVE SErFER KI'I'I'] Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 1 2339 10" 1229 1843 2458 1 3687 OECTM OF FLOW Al OUTDOOR INSTALLATION DIMENSIONS (approx) Al SETTER Al SETTER MODEL SIZE END TO END TO END END FLS MiS In. I mm in. lmm In. 'mm 4 I 100 315/161 795 29.3131745 6 I 150 .343/4 I 884 32.75 1832 8 I 200 1 47 11194 44.62511133 10 I 250 1 51 112951 47 1111941 SPECIFICATIONS The Double Check Detector Backflow Preventer shall beASSE® Listed 1048 and supplied with full port OS &Y gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYL,the stem shall be stainless steel (ASTM A276) and the seat disc elastomers shall be EPDM. The checks shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Preventer shall be a WILKINS Model 4500A. Page 2 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 112 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zum.com