HomeMy WebLinkAbout2870 WHIPTAIL LP; ; AS160304; PermitCity of Carlsbad Sprinkler Permit Permit No: ASI 60304 Job Address: 2870 WHIPTAIL LP Permit Type: SPRINK Parcel No: 2091201000 Lot #: 0 Status: ISSUED Applied 9/26/2016 Approved: 10/19/2016 Reference No.: Issued: 10/19/2016 PC #: Inspector: Project Title.:. UNITE EUROTHERAPY TI:FIRST FLOOR SPRINKLER TI. FOR SUITE Al &A2 Applicant: EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY SAN MARCOS, CA 760-310-6122 Owner: TECHBILT CONSTRUCTION CORP P 0 BOX 80036 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 303 0 303 0 a) I 100 — 0 150 CL 250 Supply / Demand Graph --------r 200 50 0- 075 150 146.56 psi available at with System Flow of 496.0 GPM Sprinkler Demand of 64.69 psi Vol 41 Margin: +55.9% 1:':; : 225 300 375 450 Water Flow (GPM) 525 600 08800 Dashboard Das/7boardHyd,rnillcs Hydraulics Summary Sheet Project Information Calculation Date: 9/22/201611:04:24 AM UNITE EUROTHERAPY TI system ID drawing ref MEZZANINE CALC building NEW 2870 WHIPTAIL LOOP construction CONCIWOOD CARLSBAD, CA occupancy WHSE contract # authority - Contractor Information EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY SAN MARCOS, CA 92069 calculated by ADAM BOISVERT telephone 760-310-6122 fax 760-798-0556 email EPICFIRE@COX.NET Sprinklers in Remote No. Mfgr Mod SlN# Size K 6 1 GLOBE EC GL8901 1 3/4" 18.1 Hydraulics Criteria density .10 GPM/ft2 system type WET design std NFPA 13 remote area 1500 ft' hazard LIGHT spr coverage 20x20 ft' sprs flowing 6 figure calc'd volume 10,964.1 gal curve rIrIA, Tc+ static pressure 146.70 psi residual pressure 122.40 psi quantity flowing 8,000.0 GPM elevation from if 0.00 ft date & time of flow test 2-18-16 location of flow test SITE 0 Ct') 0 Copyright 2013 Sigma Development Group, Inc. Page 1 of 9 UNITE EUROTHERAPY TI MEZZANINE CALC / Pressure / Total / Total / System / Pressure / Available / Flow / Required 7 146.56 psi 496.0 GPM 1 64.69 psi Supply Analysis Dashboard Hydraulics Quantity / Static /Pressure / Residua/Flowing Node /Pre ssure (_Source Zero 146.70 psi 122.40 psi 8,000.0 GPM Sprinkler Flow: 246.0 GPM Additional Flows: 250.0 GPM Hose Flow at Zero: None Total System Flow: 496.0 GPM Maximum velocity in pipe 423 - 450 is 17.0 ft/sec Nodes Analysis Minimum Node Actual Node Elev Device KFactor Flow Pressure Discharge Notes ft GPM psi GPM 463 15.0 Sprinkler 8.10 40.00 24.39 40.00 464 15.0 Sprinkler 8.10 40.00 24.86 40.38 465 15.0 Sprinkler 8.10 40.00 24.98 40.48 462 15.0 Sprinkler 8.10 40.00 25.81 41.15 461 15.0 Sprinkler 8.10 40.00 26.08 41.36 460 15.0 Sprinkler 8.10 40.00 27.63 42.58 2 0.0 Hose Flow 64.46 250.0 © Copyright 2013 Sigma Development Group, Inc. Page 2 of 9 QUO' Dashboard Hydraulics Pipe Information UNITE EUROTHERAPY TI MEZZANINE CALC From Elevl Pipe ID Flows Length ft [ C Value [Total (Pt) psi ft Added GPM Inside Diameter Fittings i I Notes Fitting ft I Elev (Re) psi To Elev2 Type in IFriction Lossi Total Total ft [ psi/ft [Frict (Pt) psi 453 17.00 1" Dyna Thead 1.0800 T,E Len 8.0 Ftg 8.1 c = 120 Pt 463) 24.387 Pe -0.866 Pt 6.541 463 15.00 AO 40.0 0.40709 Total 16.1 Total Pressure at Node 453) 30.062 psi 455 17.00 1" Dyna Thead 1.0800 T,E Len 4.5 Ftg 8.1 0=120 Pt 465) 24.980 Pe -0.866 Pt 5.231 465 15.00 AO 40.5 0.41624 Total 12.6 453 17.00 lW Dyna Flow 1.7280 0 Len 17.0 Ftg 0.0 0=120 Pt 455) 29.344 Pe 0.000 Pf 0.717 455 17.00 BN 40.5 0.04220 Total 17.0 451 17.00 1%" Dyna Flow 40.0 1.7280 0 Len 14.0 Ftg 0.0 C = 120 Pt 453) 30.061 Pe 0.000 Pf 2.106 453 17.00 BN 80.5 0.15044 Total 14.0 Total Pressure at Node 451) 32.167 psi 454 17.00 1" Dyna Thead 1.0800 T,E Len 5.0 Ftg 8.1 c = 120 Pt 464) 24.859 Pe -0.866 pf 5.414 464 15.00 AO 40.4 0.41437 Total 13.1 452 17.00 1%" Dyna Flow 1.7280 0 Len 17.0 Ftg 0.0 C = 120 Pt 454) 29.406 Pe 0.000 Pt 0.714 454 17.00 BN 40.4 0.04201 Total 17,0 Total Pressure at Node 452) 30.121 psi 452 17.00 1" Dynalhead Len 4.0 C = 120 Pt 462) 25.810 1.0800 T,E Ftg 8.1 Fe -0.866 462 15.00 AO 41.2 0.42902 Pt 5.177 Total 12.1 450 17.00 1%" Dyna Flow 40.4 Len 14.0 c = 120 Pt 452) 30.121 1.7280 0 Ftg 0.0 Pe 0.000 452 17.00 BN 81.5 0.15410 Pf 2.157 Total 14.0 Total Pressure at Node 450) 32.278 psi 451 17.00 1" Dyna Thead Len 8.0 c = 120 Pt 461) 26.075 1.0800 T,E Ftg 8.1 Pe -0.866 461 15.00 AO 41.4 0.43310 Pt 6.958 Total 16.1 424 17.00 1%" Dyna Flow 80.5 Len 18.0 0=120 Pt 451) 32.167 1.7280 T Ftg 11.3 Pe 0.000 451 17.00 BN 121.8 0.32401 Pt 9.490 Total 29.3 Total Pressure at Node 424) 41.658 psi © Copyright 2013 Sigma Development Group, Inc. Page 3 of 9 TpO Pipe Information UNITE EUROTHERAPY TI MEZZANINE CALC Pipe ID Flows Length I C Value I Total (Pt) psi From ft Added GPM Inside Diameter Fittings Notes Fitting ft I I Elev (Pe) psi To Elev2 Type in IFriction Lossi Total Total ft psi/ft Frict (Pt) psi 450 17.00 1" Dyna Thead 1.0800 T,E Len 4.0 Ftg 8.1 c = 120 Pt 460) 27.631 Pe -0.866 Pt 5.514 460 15.00 AO 42.6 0.45693 Total 12.1 423 17.00 11/2' Dyna Flow 81.5 1.7280 T Len 18.0 Ftg 11.3 C = 120 Pt 450) 32.278 Pe 0.000 Pf 9.820 450 17.00 BN 124.1 0.33526 Total 29.3 Total Pressure at Node 423) 42.098 psi 246 37.33 2%" Dyna Flow 2.7030 E Len 56.5 Ftg 9.3 C = 120 Pt 420) 44.277 Pe 0.000 Pt 1.802 420 37.33 BL 104.0 0.02737 Total 65.8 241 37.33 2V2" Dyna Flow 2.7030 E Len 10.0 Ftg 9.3 C = 120 Pt 246) 46.079 Pe 0.000 Pt 0.529 246 37.33 BL 104.0 0.02737 Total 19.3 240 37.33 2%" Dyna Flow -35.4 2.7030 1 Len 10.0 Ftg 18.7 C= 120 Pt 241) 46.608 Pe 0.000 Pt 0.363 Total 28.7 241 37.33 BL 68.6 0.01268 Total Pressure at Node 240) 46.971 psi 242 37.33 2Y2" Dyna Flow 2.7030 0 Len 43.5 Ftg 0.0 C 120 Pt 420) 44.277 Pe 0.000 Pt 2.116 420 37.33 BL 141.9 0.04863 Total 43.5 243 37.33 21/2" Dyna Flow -49.5 2.7030 T Len 8.0 Ftg 18.7 C = 120 Pt 242) 46.393 Pe 0.000 Pt 0.587 242 37.33 BL 92.5 0.02202 Total 26.7 244 37.33 2%" Dyna Flow -33.3 2.7030 0 Len 0 8. Ftg 0.0 C = 120 Pt 243) 46.979 Pe 0.000 }f 0.077 243 37.33 BL 59.2 0.00963 Total 8.0 245 37.33 2'/" Dyna Flow -31.2 2.7030 0 Len 8.0 Ftg 0.0 C 120 Pt 244) 47.056 Pe 0.000 Pt 0.019 244 37.33 BL 28.0 0.00241 Total 8.0 400 37.33 2'/" Dyna Flow 2.7030 5E Len 110.0 Ftg 46.6 C 120 Pt 245) 47.076 Pe 0,000 Pt 0.378 245 37.33 BL 28.0 0.00241 Total 156.6 229 37.33 21/2 Dyna Flow 2.7030 T Len 41.8 Ftg 18.7 C = 120 Pt 400) 47.454 Pe 0.000 Pt 0.146 400 37.33 BL 28.0 0.00241 Total 60.4 © Copyright 2013 Sigma Development Group, Inc. Page 4 of 9 E3 88'OO Dashboaid Hydraulics Pipe Information UNITE EUROTHERAPY TI MEZZANINE CALC From Elevi Pipe ID Flows Length ft C Value [Total (Pt) psi ft Added GPM Inside Diameter Fittings I Notes Fitting ft I Elev (Pe) psi I To ft Elev2 Type in Friction Loss Total Total ft [ psi/ft [Frict (Pt) psi 209 36.50 2%" Dyna Flow 2.7030 1 Len 0.8 Ftg 18.7 c = 120 Pt 229) 47.599 Pe 0,359 Pf 0.047 229 37.33 RN 28.0 0.00241 Total 19.5 208 36.50 6' Sch 10 6.3570 0 Len 8.0 Ftg 0.0 = 120 Pt 209) 48.006 Pe 0.000 Pt 0.000 209 ______ 36.50 CM1 28.0 0.00004 Total 8.0 Total Pressure at Node 208) 48.006 psi 228 37.33 2%" Dyna Flow 2.7030 TIT Len 143.8 Ftg 37.3 C = 120 0.00294 Pt 244) 47.056 Pe 0.000 Pt 0.533 244 37.33 BL 31.2 Total 181.1 208 36.50 2%" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 228) 47.589 Pe 0.359 Pt 0.057 228 37.33 RN 31.2 0.00294 Total 19.5 207 36.50 6" Sch 10 28.0 6.3570 0 Len 8.0 Ftg 0.0 C = 120 Pt 208) 48.006 Pe 0.000 Pf 0.001 208 36.50 CM1 59.2 0.00015 Total 8.0 Total Pressure at Node 207) 48.007 psi 227 I 37.33 I 2%" Dyna Flow Len 8 143. C = 120 Pt 243) 46.979 2.7030 111 Ftg 37.3 Pe 0.000 243 37.33 BL 33.3 0.00333 Pt 0.603 Total 181.1 207 36.50 21/2" Dyna Flow 8 Len 0.C= 120 Pt 227) 47.583 2.7030 1 Ftg 18.7 Pe 0.359 227 37.33 RN 33.3 0.00333 Pf 0.065 Total 19.5 206 36.50 6" Sch 10 59.2 Len 0 8. C = 120 Pt 207) 48.007 6.3570 0 Ftg 0.0 Pe 0.000 207 36.50 CM1 92.5 0.00034 Pt 0.003 Total 8.0 Total Pressure at Node 206) 48.010 psi 226 37.33 21/V Dyna Flow 2.7030 Len 143.8' T Ftg 18.7 C = 120 Pt 242) 46.393 Pe 0.000 Pt 1.123 242 37.33 BL 49.5 0.00692 Total 162.4 206 36.50 2%" Dyna Flow 2.7030 T Len 0 .8 Ftg 18.7 C = 120 Pt 226) 47.516 Pe 0.359 Pf 0.135 226 37.33 RN 49.5 Total 19.5 205 36.50 6" Sch 10 92.5 6.3570 0 Len 10.0 Ftg 0.0 C = 120 Pt 206) 48.010 Pe 0.000 Pt 0.008 206 36.50 1 CM1 141.9 0.00076 Total 10.0 © Copyright 2013 Sigma Development Group, Inc. Page 5 of 9 oo Dashboard HydraulIcs Pipe Information UNITE EUROTHERAPY TI MEZZANINE CALC From Elevl Pipe ID Flows Inside Length ft I C Value I Total (Pt) psi ft Added GPM Diameter Fittings Fitting ft Elev (Pe) psi Notes To ft Elev2 Type in Friction Lossi Total Total ft psi/ft j Frict (Pf) psi Total Pressure at Node 205) 48.018 psi 225 37.33 2'/z" Dyna Flow 2.7030 1 Len 243,8 Ftg 18.7 c = 120 0.00373 Pt 241) 46.608 Pe 0.000 Pf 0.978 241 37.33 BL 35.4 Total 262.4 205 36.50 2%" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 c = 120 Pt 225) 47.585 Pe 0.359 Pt 0.073 225 37.33 RN 354 0.00373 204 36.50 6' Sch 10 141.9 6.3570 0 Len 10.0 Ftg 0.0 c= 120 Pt 205) 48.018 Pe 0.000 Pt 0.011 205 36.50 CM1 177.3 0.00114 Total 10.0 Total Pressure at Node 204) 48.029 psi 234 37.33 21/2" Dyna Flow 2.7030 T Len 83.8 Ftg 18.7 C = 120 Pt 240) 46.971 Pe 0.000 Pf 0.484 240 37.33 BL 40.2 0.00472 Total 102.4 214 36.50 2½" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 c = 120 0.00472 Pt 234) 47.455 Pe 0.359 Pf 0.092 234 37.33 RN 40.2 213 36.50 4" Dyna Flow 4.3100 0 Len 8.0 Ftg 0.0 0=120 Pt 214) 47.906 Pe 0.000 Pf 0.004 214 36.50 CM2 40.2 0.00049 Total 8.0 212 36.50 4" Dyna Flow 9,4 4.3100 0 Len 8.0 Ftg 0.0 0=120 Pt213) 47.910 Fe 0.000 Pt 0.002 213 36.50 CM2 30.8 0.00030 Total 8.0 211 36.50 4" Dyna Flow 97 4.3100 0 Len 8.0 Ftg 0.0 = 120 0.00015 Pt 212) 47.913 Pe 0.000 Pt 0.001 212 36.50 CM2 21.1 Total 8.0 210 36.50 4' Dyna Flow -10.3 4.3100 0 Len 10.0 Ftg 0.0 0=120 Pt 211) 47.914 Pe 0.000 Pt 0.000 211 36.50 CM2 10.8 0.00004 Total 10.0 230 37.33 21/2" Dyna Flow 2.7030 1 Len 0.8 Ftg 18.7 0=120 Pt 210) 47.914 Fe -0.359 Pf 0.008 210 36.50 RN 10.8 0.00042 Total 19.5 220 37.33 2%" Dyna Flow 2.7030 T/2E,T Len 330.0 Ftg 56.0 C = 120 0.00042 Pt 230) 47.563 Pe 0.000 Pf 0.160 230 37.33 BL 10.8 Total 386.0 © Copyright 2013 Sigma Development Group, Inc. Page 6 of 9 oO Pipe Information UNITE EUROTHERAPY TI MEZZANINE CALC From Elevi ft Pipe ID Flows Added Inside Length ft I I C Value T Total (Pt) psi I Fitting ft I I Elev (Pe) psi I GPM Diameter in Fittings Friction Loss psi/ft Notes To Elev2 Type Total Total ft Frict (Pf) psi 200 36.50 21/P Dyna Flow 2.7030 T Len 0.81 Ftg 18.7 C = 120 Pt 220) 47.723 Pe 0.359 Pf 0.008 220 37.33 RN 10.8 0.00042 Total 19.5 Total Pressure at Node 200) 48.090 psi 224 37.33 2%" Dyna Flow 2.7030 1 Len 244.3 Ftg 18.7 c = 120 Pt 240) 46.971 Pe 0.000 Pf 0.650 240 37.33 BL 28.4 0.00247 Total 262.9 204 36.50 2%" Dyna Flow 2.7030 ____ Total T Len 0.8 Ftg 187 = 120 Pt 224) 47.621 Pe 0.359 Pf 0.048 224 37.33 RN 28.4 0.00247 36.50 6" Sch 10 19.5 203 77.3 [205.7 6.3570 0 Len 8.0 Ftg 0.0 = 120 Pt 204) 48.029 Pe 0.000 Pf 0.012 204 36.50 CM1 ____ 0.00150 Total 8.0 Total Pressure at Node 203) 4.8.041 psi 233 37.33 2%" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 P1:213) 47.910 Pe -0.359 Pf 0.006 213 36.50 RN 9.4 0.00032 - Total 19.5 223 37.33 21/2" Dyna Flow 2.7030 TIT 0 Len 328.C= Ftg 37.3 120 Pt 233) 47.557 Pe 0.000 Pf 0.118 233 37.33 BL 9.4 0.00032 Total 365.3 203 36.50 2Y2° Dyna Flow 2.7030 T 8 Len 0.0 Ftg 18.7 = 120 Pt 223) 47.675 Pe 0.359 Pf 0.006 223 37.33 RN 9.4 0.00032 Total 19.5 202 36.50 6" Sch 10 205.7 6.3570 0 Len 10.0 Ftg 0.0 C = 120 Pt 203) 48.041 Pe 0.000 Pf 0.016 203 36.50 CM1 215.2 0.00163 Total 10.0 Total Pressure at Node 202) 48.057 psi 232 37.33 2%" Dyna Flow 8 Len 0.C= 120 Pt 212) 47.913 2.7030 1 Ftg 18.7 Pe -0,359 212 36.50 RN 9.7 0.00034 Pf 0.007 Total 19.5 222 37.33 2Y" Dyna Flow Len 330.0 C= 120 Pt 232) 47.560 2.7030 T/2E,T Ftg 56.0 Pe 0.000 232 37.33 BL 9.7 0.00034 Pf 0.132 202 36.50 21/2 Dyna Flow Len 0.8 C = 120 Pt 222) 47.691 2.7030 T Ftg 18.7 Pe 0.359 222 37.33 RN 9.7 0.00034 Pf 0.007 Total 19.5 0 Copyright 2013 Sigma Development Group, Inc. Page 7 of 9 88OO Pipe Information UNITE EUROTHERAPY TI MEZZANINE CALC From Elevi Pipe ID Flows Inside Length ft I I C Value 1 Total (Pt) psi I ft Added GPM Diameter Fittings Fitting ft I I Elev (Pe) psi Notes To EIev2 Type in Friction Loss Total Total ft psi/ft Frict (Pf) psi 201 36.50 6' Sch 10 215.2 6.3570 0 Len 10.01 Ftg 0.0 C = 120 Pt 202) 48.057 Pe 0.000 Pt 0.018 202 36.50 CM1 224.9 - 0.00177 Total 10.0 Total Pressure at Node 201) 48.075 psi 231 37.33 2%" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 c = 120 Pt 211) 47.914 Pe -0.359 Pt 0.007 211 36.50 RN 10.3 0.00038 Total 19.5 221 37.33 2Yz"DynaFlow 2.7030 TI2E,T Len 332.0 Ftg 56.0 C= 120 Pt 231) 47.561 Pe 0.000 Pt 0.147 231 37.33 BL 10.3 0.00038 Total 388.0 201 36.50 2½'DynaFlow 2.7030 1 Len 0.8 Ftg 18.7 = 120 Pt 221) 47.708 Pe 0.359 Pf 0.007 221 37.33 RN 10.3 0.00038 Total 19.5 200 36.50 6" Sch 10 224.9 6.3570 0 Len 8.0 Ftg 0.0 = 120 Pt 201) 48.075 Pe 0,000 Pt 0.015 201 36.50 CM1 235.1 0.00192 Tot al 8.0 Total Pressure at Node 200) 48.090 psi 0.00 10" PVC CL200 9.4200 0 Len 350.0 Ftg 0.0 150 Pt 2) 64.459 Pe 0.000 Pt 0.017 2 0.00 LU 113.8 0.00005 Total 350.0 4 0.00 10" PVC CL200 9.4200 5EE Len 950.0 Ftg 61.5 C = 150 Pt 3) 64.476 Pe 0.000 Pf 0.050 3 0.00 LU 113.8 0.00005 Total 1,011.5 1 0.00 10" PVC CL200 9.4200 5EE Len 910.0 Ftg 61.5 C = 150 Pt 4) 64.526 Pe 0.000 jf 0.048 4 0.00 LU 113.8 0.00005 Total 971.5 Total Pressure at Node 1) 64.573 psi r 1 0.00 10" PVC CL200 9.4200 T,EE Len 180.01 Ftg 68.2 C = 150 Pt 2) 64.459 Pe 0.000 Pf 0.114 2 0.00 LU 382.1 0.00046 Total 2482 Total Pressure at Node 1) 64.573 psi 423 117.00 2'/2"Dyna Flow 2.7030 0 Len 12.0 Ftg 0.0 C= 120 1 pt 424) 41.658 Pe 0.000 I Pf 0.440 424 17.00 FM2 121.8 - 0.03667 Total 12.0 © Copyright 2013 Sigma Development Group, Inc. Page 8 of 9 13 8OO Dashboard HydraulIcs Pipe Information UNITE EUROTHERAPY TI MEZZANINE CALC From Elevl Pipe ID Flows Inside Length ft l C Value 1 Total (Pt) psi ft Added GPM Diameter Fittings I I Notes Fitting ft I Elev (Pe) psi I To Elev2 Type in Friction Loss Total Total ftj psi/ft j Frict(Pf) psi 422 17.00 2Y2'Dyna Flow 124.1 2.7030 0 Len 12,0 Ftg 0.0 C = 120 Pt 423) 42.098 Pe 0.000 Pt 1.614 423 17.00 FM2 246.0 0.13448 Total 12.0 421 17.00 21/"Dyna Flow 2.7030 E Len 7.1 Ftg 9.3 C = 120 Pt 422) 43.711 Pe 0.000 Pt 2.206 422 17.00 FM2 246.0 0.13448 420 37.33 2Yz" Dyna Flow 2.7030 T,E Len 25.3 Ftg 28.0 120 Pt 421) 45.918 Fe -8.803 Pt 7.169 421 17.00 FM2 246.0 0.13448 Total 53-3 1 Total Pressure at Node 420) 44.283 psi 9 36.50 6' Sch 10 6.3570 3E Len 52.9 Ftg 52.8 C = 120 Pt 200) 48.090 Fe 0.000 Pf 0.221 200 36.50 FM 246.0 0.00209 Total 105.7 7 2.00 6' Sch 10 6.3570 BV/E Len 36.0 Ftg 30.2 C = 120 0.00209 Ft 9) 48.311 Fe 14.939 Ft 0.138 9 36.50 - FR 246.0 Total 66.2 6 0.00 6" Sch 10 6.3570 2E Len 4.0 Ftg 35.2 = 120 Pt 7) 63.398 Pe 0.866 Ft 0.082 7 2.00 FR 246.0 0.00209 Total 39.2 2 0.00 8 pvc cuoo 76800 T,GV/CV ,EE,E Len 65.0 Ftg 139.0 C = 150 Pt 6) 64.347 Fe 0.000 Pt 0.112 6 0.00 UN 246.0 0.00055 Total 204.0 Total Pressure at Node 2) 64.459 psi 0 0.00 12' PVC CL200 Len 190.01 C 150 Pt 1) 64.573 4 psi loss for DDC shown as elevtion 11.2000 T,4E Ftg 185.9 Pe 0.000 1 0.00 UN 496.0 Total 375.9 0.00032 pf 0.121 Total Pressure at Node 0) 64.694 psi © Copyright 2013 Sigma Development Group, Inc. Page 9 of 9 r%IATERIAL DATA SUBr"-IITTAL UNITE ELJROTHERIAPY TENANT IhIPROVENIENT EPIC FIRE PROTECTION, INC. 75 TURTLE POINT WAY SAN NIARCOS, CA 32000 (700)310-0122 FAX(7O)798-055 AS l 60304 2870 WHIPTAIL LP (T,14m. a FIRE SPRINKLER CORPORATION QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT. PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT. PENDENT. VERTICAL SIDEWALL HORIZONTAL SIDEWALL. CONVENTIONAL (OLD STYLE) Pp(IpIrATInM.c DESCRIPTION AND OPERATION CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices temperature ratings and finishes to meet many varying design requirements. Quick QUICK RESPONSE Response Sprinklers should be used advisedly and under the UPRIGHT CONVENTIONAL direction of approving authorities having jurisdiction. The heart of Globes GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. QUICK RESPONSE VERTICAL -See reverse side for Approvals and Specifications. SIDEWALL -Water Working Pressure Rating - 175 psi (12 Bars) ~Mb Factory tested hydrostatically to 500 psi (34 Bars) -Temperature Ratings - 135°F (57°13), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) om Maxim um low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE Frame - bronze • Deflector - brass • Screw - brass HORIZONTAL LPC!CE -Lodgement Wire - stainless steel • SIDEWALL HORIZONTAL SIDEWALL Bulb seat - copper • Spring -nickel alloy • Seal - teflon -Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATINtItI A.cicirdThw nd ('(51 n [CLASSIFICATION AVAILABLE SPRINKLER B B UL COLOR N.F.P.A. MAXIMUM I TEMPERATURES CEILING TEMPERATURE ORDINARY 135'F1155°F 57°C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C L HIGH 286F 141°C BLUE 225°F 107°C 4O77AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989.846.4583 F,4X989-846-9231 JULY 2012 A-20 BULLETIN GL5615, REV. #9 NOMINAL °K' FACTOR I THREAD SCrE I LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 114" (5.7cm) 4.2 (59 metric) I 1/2" NPT 2 114" (5.7cm( Factory Bronze 5.6 (80 metric) 1/2" NPT 2114" (5.7cm) chrome 7.8 (111 metric) I 1/2" NPT 2 1/4' (5.7cm) While Polyester 8.1 (116 metric) 3/4" NPT 27/16" (6.2cm) Btack Polyester ' ME] HIS COlA/ENS/OHS ARE APPROXIMATE 'HORIZONTAL SIDEWALL IS 29/18°, 'FINISHES AVAILABLE ON SPECIAL ORDER. AVAILABLE AS p5/u. LISTED CORROSION RESISTANT WHEN SPEC/FED ON ORDER. APPROVALS STYLE SIN HAZARD' 135F 135°F 175°F 2W"F 566F I " CE tA/C. DOB MODEL FACTOR S/°C W°C 79°C 03°C 14VC MEA I0I.62-E 015615 28 LA X X X X X X - - - x 0L4215 4.2 LA S X X X X X - - - S UPRIGHT 015615 5.6 LB/OH S S X X S S S S X X 0/8/15 7.8' li-I/OH S X S S X S - - - X El LB/OH X X S X S S S X 11 5 122807 26 LII S S X X S S - - - S 0L428/ 4.2 LA S S X S S S - - - S PENDENT = 5.8 LI/BOA S S S 5 5 5 X S X S Dl 7.8° Ll1IOH S S S X S X X - - X 01.8156 8.1 LA/OH X X S S S S S S X S VERTICAL 0/5635 5.6 LII S S X - X S - X X - - - SIDEWALL1 018135 El UI - S - S - S - - X - S - S - - - - 0128289 28 LA X S X S S X - - - S HORIZONTAL GL42256 4.2 LH X X S X S X .- - - X SOEWALL 0L58565 5.6 LB/ON X S X X X S X - - X 01.5627, 5.6 LI-I/OH X S S S X - - S X - 0181275 8.1 LA/OH S S S 5 5 X - - - - COWIEMIIOIBAL 015624 5.8 LB/OH X X S X X - - X X - (OLD STYLE) 018156 61 LB/OH X X X X X - - X X - ,crN,r,,.XNc urmo. BE I.I5D]EU As PER THE REQUIREMENTS OF NFPAI3 AND ANY OTHER RELATED DOCUMENTS. §NORIZON1'AL SIDEWALL .UL— LISTED FOR DEFLECTOR 4° TO 12' BELOW THE CEILING, FM APPROVED 4" TON' BELOW THE CEILING. .INSTALL IN ACCORDANCE TO 6S5306 AND ANY OTHER RELATED DOCUMENTS. 'PENDENT VERTICAL SIDEWALL cULu. LISTED FOR IT MIN. SPACING. '(UPRIGHT VERTICAL SIDEWALL cUL- LISTED FOR 8° MIS. SPACING. Oft ORDINARY HAZARD Liii LIGHT HAZARD 'II? NPT GLOBE PRODUCT WARRANTY Globe agrees to mpair or mplaoe any 01 its own manufactured products found to be defective in material or workmanship for a period of one year from date of Shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). (316TR Pills SPRINKLER CORPORATION JUNE 2012 TECHNICAL DATA PENDENT ORDERING INFORMATION SPECIFY ° Quantity - Model Number - Style 'Orifice - Thread Sizes - Temperature Finishes desired -Quantity - Wrenches - P/N 325390 (1/2°); P/N 312366 (1.0.) 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 9894848-4583 FAX 9894846-9231 1-800-248-0278 wAw.globeSprinkler.com PRINTED U.S.A. BULLETIN GL5615, REV. #9 leyZ16" 1@2 FIRE SPRINKLER CORPORATION Quicic RESPONSE EXTENDED COVERAGE LIGHT HAZARD A UTOMA TIC SPRINKLERS MODEL GL8109 PENDENT QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD AUTOMATIC SPRINKLERS MODEL GL8109 PENDENT Sprrw-ii rirwc DESCRIPTION AND OPERATION The Globe Quick Response Model GL8109 Extended Coverage Pendent Sprinkler for Light Hazard occupan- is low cies a profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While this Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard light hazard ex- tended coverage pendent sprinklers are specified; but '. offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly - and under the direction of approving authorities having jurisdiction, in accordance with their listings and in accor- QUICK RESPONSE dance with NFPA 13. The heart of Globe's GL Series sprinkler proven EXTENDED COVERAGE PENDENT actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the pre- scribed temperature the internal pressure within the am- pule exceeds the strength of the glass causing the glass to - shatter. This results in waterdischarge which is distributed in an approved pattern. TECHNICAL DATA See reverse side for Approvals and Specifications. . -Temperature Rating - 135°F (57°C), 155°F (68°C), 175°F (79°C) and 200°F (93°C). Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). QUICK RESPONSE Maximum low temperature glass bulb rating is -67°F (-55°C). RECESSED Frame - bronze • Deflector - brass • Screw - brass EXTENDED COVERAGE a Bulb seat - copper • Spring - nickel alloy • Seal - teflon PENDENT Bulb - glass with alcohol based solution, 3mm size. Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE . BULB N.F.P.A. MAXIMUM CEILING SPRINKLER TEMPERATURES COLOR TEMPERATURE ORDINARY 135F1155F 570/680 I ORANGE/RED - 100F 38C INTER MEDIATE 175F/200F 79C/93C YELLOW/GREEN 150F -. 66C 4077AIRPARKDRrL/E, STANDISH, MICHIGAN 48658 989-846-4583 • FAX9894846-9231 JULY2005 A-41 BULLETIN GL81O9REV.#5 NOMINAL K° FACTOR THREAD SIZE LENGTH I FINISHES I Factory Bronze r3" iSat in Chrome 8-1 (116 metric) 3/4" N PT (7.6 ) I Bright Chrome I White Fayecter° I RL'rk Etatomdoe° Leaf Coated' NOTE: METRIC CONVERSIONS ARE APPROXIMATE.'FINISHES AVAILABLE ON SPECIAL ORDER 'AVAILABLE AS rULun LISTED CORROSION RESISTARTIAR-IEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K 135F 155F 175F 200°F MODEL FACTOR 57°C 68C 79°C 93°C cuLus PENDENT GL8109 8.1 X X X X X U.L. LISTING DESIGN - USE REQUIREMENTS FOR LIGHT HAZARDS ONLY SIN STYLE TEMP AREA OF NUN. PRESSURE FLOW IN GP.M. MODEL . COVERAGE P.S.I. 135F/57C 16'x 16' 10.3 26 Standard 155°F/68C 0L8109 & 175°F/79C 18' 0 18 16.6 33 Recessed 200°F/93°C 1350F/570C 20' x 20' 24.4 40 NOTE DUE TO THE HIGH SPRAY PATTERN CREATED BY THIS SPRINKLER, THERE MUST RE A MINIMUM SPACING OF 0.0" BETWEEN SPRINKLERS TO ELIMINATE THE RISK OF COLD SOLDERING. ORDERING INFORMATION T 00 aN. NIAE 0 SPECIFY I Quantity • Model Number Style Xc SIC Orifice • Temperature Finishes desired r / Quantity - Wrenches - P/N 312366 CAP Quantity - Recessed Wrenches - P/N 325401, Rev. 0 - Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) GLOBE" PRODUCT WARRANTY Globe agrees to repair or replace any of its own I/B manufactured products found lobe defective in material or workmanship for a period of one year from date of CROSS SECTION shipment. For specific details of our morranty, please refer to Price List Terms and Conditions of Sale (Our Price List). rw GRA602. 4077A1RPARK DRIVE, STANDISH, MICHIGAN 48658 989-846.4583 FAX 989-8-46-9231 FIRE SPRINKLER CORPORATION 1-800-246.0278 www.globesprinkler.com JULY2025 PRINTEDU.SA BULLETIN GL8109, REV.#5 Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alley sprinklers beyond that which mould otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests 01 the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability 01 these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should he con- sidered, as a minimum, along with the corrosive nature of the chemical 10 which the sprinklers will be exposed. WARNINGS The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers described herein must be installed and main- tained in compliance will, this docu- ment; as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any otherauthoritles hav- ing jurisdiction. Failure to dose may Impair the performance of these de- vices. The owner is responsible formainfsin. ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number TY5137 - Upright. 11.2K TY5237 - Pendant, 112K-'" TY6137 - UprIght, 14.0K TY6237 - Pendent,14,OK TY5137 is a redesignation for C5137, 61894. and S2510. TV5237 is a rednsignation for C5237, 61893, and S251 1. TY6137 is a redesignalion for C6137, 61890, and S2610. TY6237 is a redesignation for C6237, 61895, and S261 1. Fire & Building tqco/Products Technical Services: Tel: (800) 381-9312 / Fax: (BOO) 791-5500 Series EC-1 I & EC-14 — 11.2 and 14.0 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Rec. Pendent Sprinklers IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING that provides cautions with respect 10 handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its cempo- cents and cause the sprinkler to fail to operate/na ire situation or cause it to operate prematurely. Page 2 of 8 TFP22O WRENCH 3I4' - ESCUTCHEON PLATE FLAT NPT SEATING SURFACE tattor suntan Aann.vbty 4.Sure 5- Canwooekln 5vre 0' o,t,cter (61,9 mm) - Turn toronto ro/5g 4 UP RIGHT & PENDENT IIf 116 md/sated an deflector - Pip, Orrnad snve,sflaru prr 150 (427mm 7/I can On prwfldnd Os specia/ ensoul. 1/2(12.7mm) J NOMINAL MAKE-IN CROSS UPRIGHT PUNGENT SECTION FIGURE I SERIES EC-1 I AND EC-14 EXTENDED COVERAGE SPRINKLERS 01,2K-FACTOR (TY5137) UPRIGHT AND (TY5237) PENDENT 14.0 K-FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT SPRINKLER FINISH thee Note 5) HAZARD TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME 1 PLATED WHITE- IPOLYESTERI I LEAD COATED LIGHT Refer te Table nfor UL and C-UL Se058lnitp Rating and RetertoTobkCte, EN SnnottivltyRating UPRIGHT PENDENT 6=11,2 (1Y5237) K=14.0 (TY6237) 1359n157.ç Orange 1.2,3",4 K=112(7`511371 - I55"ylBEC And 175"F/70,C Totem 1,2.4 1,2,4 200F/93"CGreen 2061/141C Ott/n REC,PENDENT Krd1.2(T55237) K--14.0 (TY6237) With Style 3o Escutcheon C t,2,3,4 t,2,4 N/A t5EFlBrC Red — 175F179"C you" FA)TC Green 28EF/141C Blue oRoIey Refer to Table 8 for UL and C-UL Senoitinitn Rating and Refer to Table C for FM Sensitivity Rating UPRIGHT K=1L2(TY5137) Kn1&OfTYBI37) and PENDENT K=11,2f1Y5237) Kn14A (TY6237) 13F/5C Orange L23,4 1,2,3,4 tscrFlerc Rod — I7EF/79'C You— 1,2.4 C Green 20EFI14f"C Blue REC, PENDENT K=11.2 l'TY5237) K=14,2 )TV6237) mill, snp 40 Eeoateheoe 13arF/5rC Orange 1,2.4 N/A 15toF/6C Red 17Ff7EC - Totem 200'F193C - Gross NOTESm l.Usled by Underwriters Laboratories. Inc. (UL). 2.1.1oted by Uedemreers Laboratories, Inc. for use In Canada (C-UL). Approved by Factory Mutual fleseamh Corporation (FM). Appresod by the City of New Turk under MEA /77-03.E. Where Polyester Coated or Lead Crated sprinklers are noted lobe UL and C-UL Listed. the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Frame and Detente, only. Listings and approvals apply to color (Special Order). Purulent Only. N/A: Not Available TABLE A, LABORATORY LISTINGS AND APPROVALS General Description The Series EC-11 and EC-14 Ex- tended Coverage Uprighland Penitent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for a maslmaer cover- age area sf400112 (37,2 mZ), as com- pared 10 the maximum coverage area 01130 I12 (12.1 m2) for standard cover- age sprinklers used in ordinary haz- ard occupancies Cr 225 112 (20.6 en2) for standard coverage sprinklers used in light hazard occupancies. The Series EC-il and EC-14 Sprin- klers feature a UL and C-UL Listing that permits their use With unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NPPA 13, as well an a specific application listing for use under concrete tees. The Series EC-11 and EC-14 Ex. tended Coverage Sprinklers have been fire tested to compare their per- formance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal 10 or more effective than stand-ard coverage spray sprinklers. Page 1 of 8 SEPTEMBER, 2004 TFP22O Page 4 of 8 '1FP220 Technical Data Approvals UL and C-UL Listed. PM Approved. (Refer to Table Alor complete approval information including corrosion resis- tant status. The approvals apply to the service conditions indicated in the De- sign Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch f/IPT Discharge Coefficients K 011.2 GPM/psi'tt (161,3 LPM/bar1 ) K = 14.0 GPM/puiltt (201,6 LPM/barl°) Temperature Ratings 135'F/57°C to 286'F/I411C Finish Sprinkler: Rater to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame .............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/Telloo( Bulb ........Glass (3 mm dia.) Compression Screw ......... Bronze Deflector ............Brass Patents U.S.A. Patent Numbers 5,366,022: 5,579,646; 5,584,344; 5,8119.2/I: 5,862,994; and 5,865.256. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprin-kler to activate 804110w water. Design Criteria The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers must only he installed in accordance with the ap- plicable UL and C-UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Re-cessed Escutcheon is to be used for recessed installation, as applicable (Rot. Table A. B. and C). UL and C-UL Listing Requirements I. The Series EC-il and EC-14 Sprin- klers may be used for the coverage areas shown In Table 0, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for allot the sprinklers in the design area. The Series EC-11i and EC-14 Sprin-klers are permitted to be used with unobstructed or non-combustible obstructed coiling construction as defined and permitted by NFPA 13. For example: Unobstructed, combustible or eon—combustible, coiling construction With a deflector to coiling/root dock distance 011 to 12 inches (25 to 300 mm). Obstructed, eon-combustibte, ceil-ing construction with a deflector lo- cation below structural members of I to inches 125 to 150 mm) and a maximum deflector to coiling/roof deck distance of 22 inches (550 mm). The Series EC-1 1 and EC-14 Sprin- klers having been specifically tested and listed for non-combustible ob- structed construction are permitted lobe used within trnjsnesorbarioistu having eon-combustible web wem- hers greater than 1 inch (25.4 row) when applying the 4 times obstruc- tion criteria rule defined under 'Ob- structions to Sprinkler Discharge Pat/em Development". The minimum allowable spacing be-tween the Series EC-11l 8114 EC-14 Sprinklers, to prevent cold solder- ing, is Bleet(2.4 m( for upright sprin-klers and 9 feet (2.7 m) for pendent sprinklers. o. The Series EC-1 1 and EC-14 Sprin- klers are to be installed in accord- ance with all Other requirements of NFPA 13 for extended coverage up- right and pendent sprinklers. For ex- ample: obstructions to sprinkler dis- charge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to stor-age, et UL and C-UL Specific Application Listing Requirements For Installation Under Concrete Tons The Series EC-11 and EC-14 Ex-tended Coverage Upright and Pendent Sprinklers (1Y5137,TY5237, TY6137 & TV6237) have a UL and C-UL Spe- cific Application listing for use under concrete tees when installed as fol-lows: The stems of the concrete tee con- structIon must spaced at less than 7.5 feet (2.3 m) on center but more than 3 feet (0,9 m( on center. The depth of the concrete fees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length en-coeds 32 feel (9,8 m), non-combus- tible baffles, equal in height to the depth of the tees, can he instafiedse that the space between the lees does not exceed 32 feet (9,8 m) in length. The sprinkler detectors are to he located in a horizontal plane at or above I inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler defectors are located higher than a horizontal plane 1 inch (251,4 mm) beneath the bottom 01 the concrete tee stems, the obstruct/on to sprinkler dis-charge criteria requirements of NFPA 13 for extended coverage up- tight sprinklers applies. FM Approval Requirements The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers are to be installed in accordance with the appli- cable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam-mable or combustible liquid) occupan- cies. Information provided in the FM Loss Prevention Data Sheets relate to. but are not limited to, hydraulic design, ceiling slope and obstructions, mini-mum and maximum allowable spas- leg, and deflector-to ceiling distance. These criteria may differ from UL and/or NFPA criteria, therefore the de-signer should review and become fa- miliar with Factory Mutual require- ments before proceeding with design. TFP220 Page 3ofB LIGHT HAZARD ORDINARY HAZARD 135'F 155*F 175'F SCOW 285W 135'F 155'F 175'F 200'F 286'F AREA STYLE 14014 Up. on Pond. —— SR SR SR SIR 14014 Style 30Recesued SR SR SR WA 14n14 Style 4ORocessed SR SR SR N/A - 16016 Up. orPand. OR, OR' OR' ——— -- SR OR' OR' SR SR SR SR SR 16016 StnJle3ORecessed OR' OR' 0R OR' OR' SR SR SR SR N/A 16016 Style 40Recessed N/A N/A -—————-SR -—————- - SR N/A I/I/A N/A SR SR SR SR N/A 18018 Up. orPend. OR' OR' on, OR' OR, SR SR SR SR SR 18018 StyIe34Recessed 0R OR' an- on- OR' SR SR SR SR N/A 18n18 Slvle40 Recessed N/A N/A N/A N/A N/A OR SR SR SR N/A 20020 tip. or Pond. OR' OR' OR, OR' OR' SR SR SR SR SR 25020 Style 3SRecessed OR, OR' OR' OR' OR' SR SR SR SR N/A 20020 Style 40 Recessed N/A I/I/A N/A N/A N/A SR SR OR SR N/A OR: Oreek Response OR: Standard Response f/I/A: Net Applicable 'Does not apply In Upright 14.0 - - . TABLES SENSIIIVITY RATING FOR UL AND -UL LISTiNG OF SERIES EC-Il C OR EC-14 SPRINKLERS (SEE TABLED FOR PERMITTED K-FACTOR/AREA COMBINATIONS) LIGHT HAZARD ORDINARY HAZARD I35'F 155'F I75'F 200*F 286W 135W 155'F I75'F 260F 206'F AREA STYLE 14014 Up. onPond SR SR on on 14n14 Style 30Recessed N/A WA N/A N/A 14014 Style 4vRecessed N/A N/A N/A N/A 16016 Upon Pond. OR' OR' N/A N/A N/A SR SR SR SR SR /6016 Style 3ORecessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A /6016 Style 40 Recessed N/A N/A N/A N/A N/A N/A IA/A N/A N/A N/A 18018 Up- onPend. OR, OR' - - -———— -- p - - -———— -- N/A - - -———— - N/A N/A N/A N/A OR SR SR SR SR 18018 Style 30Recessed OR OR I/I/A N/A N/A N/A N/A N/A IA/A N/A 16018 Slyte40 Recessed N/A N/A N/A N/A N/A N/A N/A I/I/A N/A N/A 20020 Up. or Pond. OR' OR' N/A N/A N/A SR SR OR OR OR 20020 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 20020 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A WA N/A N/A OR: Quick Response OR: Standard Response N/A: Not Applicable 'Pendent Only TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-1 I OR EC-14 SPRINKLERS (SEE FM LOSS PREVENTION DATA SHEET 2-8N FOR PERMITTED K-FACTOR(AREA COMBINATIONS) TFP22O Page 5 of B 4-I10 Ut/I. 5/8±1/4" (73,0 mm) 34'(19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) SPRINKLER 1/8" FITtiNG (3,2 mm) - MOUNTING MOUNTING SURFACE PLATE CLOSURE 1-3/8 (34,9 mm) 7/8'(22,2 mm) FIGURE 3 SERIES EC-1 I AND EC-14 RECESSED PENDENT SPRINKLER ASSEMI WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 2-7/8" DIA. 1/2±1/8" - (73,0 mm) 1/2" (12,7 mm) ) (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) FACE OF (57 mm) "] 1/8 SPRINKLER FITTING MOUNTING MOUN11NG SURFACE PLATE CLOSURE 1-3/8" (34,9 mm) 1-1/8"(28,6 mm) FIGURE 2 SERIES EC-Il AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS FIGURE 4 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS WRENCH HEX FIGURES W-TYPE 22 RECESSED SPRINKLER WRENCH Page 6of8 IFP220 GROUP I GROUP 8 UGI'IT HAZARD ORDINARY HAZARD ORDINARY HAZARD 0_1a GPMIFI' 0_1ls GPMIFI' 0.20 GPM/FT' DESCRIPTION AREA GPM PSI GPM PSI GPM PSI TY5137 IK=11,21 UPRIGHT 14 H 14 - - 30 7.2 39 12.1 16016 30 7.2 39 12.1 01 20.7 18 HIS 33 8.7 49 19.1 65 33.7 20H20 40 12.8 60 28.7 80 51.0 TY5237 IKo11.21 PENDENT 14 H 14 - - 30 7.2 39 12.1 16 516 30 7.2 39 12.1 51 20.7 18x18 33 0.7 49 18,1 65 33.7 20020 40 12.8 60 28.7 00 51.0 T56137(K,i42)UPRIGHT 14H14 N/A N/A - - - - lee to N/A N/A 39 7.8 51 13.3 18H18 N/A N/A 49 12.3 65 21.6 20 H 20 N/A N/A 60 18.4 00 32.7 'T'Y6237 IK=14.0I PENDENT 14,14 - - - - - - 18 H 16 37 7.0 39 7.8 Si 13.3 18x18 37 7,0 49 12.3 65 21.6 20020 40 8.2 60 16.4 80 32.7 It. 0.2048W lit0 = 0.093 rnt I gpin = 3.785 fpm I pRi0.06895ba0 1 gpnd82 = 40.74 mrrslnon TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OFSERIES EC-1 I AND EC-I4 SPRINKLERS Step 1. The sprinkler must be installed Installation with the deflector parallel 10196 mount- ing surface. Pendent sprinklers must The Series EC-11 and EC-14 Spnin- be installed in the pendent position, klers must be installed in accordance and upright sprinklers must be in- with the following Instructions: stalled in the upright position. NOTES Step 2. After installing the Style 30 or Do not install any bulb type sprinkler if 40 mounting plate (or other escutch- the bulb is cracked or thereis loss of Son, as applicable) over the sprinkler liquid from the bulb. With the sprinkler pipe threads and with PIPE thread held horizontally, a small air bubble sealant applied to the pipe threads, should be present. The diameterof the hand tighten the Sprinkler into the air bobbin is approximately 1/16 inch sprinkler titling. (8,6 mm) for the 135F/5rC to 3/32 Step 3. wrench tighten upright or pen- inch (2.4 mm) for the 286"F/141"C dent sprinklers using only the W-Type temperature ratings. 3 (End A) Sprinkler Wrench, Wrench A leak tight 3/4 inch NPT sprinkler joint tighten the recessed pendent sprin- sits utdbe obtained with a torque of 10 klers using only the W-Type 22 Sprin- 1020 fl.lbs. (83,4 to 26,8 Nm). A maxi- kier Wrench. The wrench recess of the mum of 30 (rIbs. (40.7 Alm) of torque applicable sprinkler wrench (Ref. Fig- Is to be used to install sprinklers. ura 4 and 0) is to be applied to the Higher tenets of torque may distort the sprinkler wrench flats (Ref. Figure 1). sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficinntadjustment in an Escutcheon Plate by under- or ore r.tighte ring the Sprinkler. Readjust the position of the sprinkler lilting to suit. TFP22O Page 7 of 8 Page 8 of 8 TFP22O Care and Maintenance The Series EC-11 and EC-I4 Sprin- klers must be maintained and serviced in accordance with the following in- structions: NOTE Before closing a fire protection system male control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection systems must be obtained from the proper authori-ties and all personnel who may be affectecfby this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered alter leaning the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam-age to the sprinklers - before, during. and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage. or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. )Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, 10 verily the integrity of the cor-rosion resistant coating. Thereafter, annual inspectIons per NFPA 25 should suffice; however, instead of in- specting from the hoar level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the enact sprinkler condi- tion and the long term integrity 01 the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their lire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g.. NFPA 25), in addition to the standards of any other authorities having jurisdiction. The In- stalling contractor or sprinkler manu-facturer should be contacted relative In any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance With local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten It 0) years from date of ship- ment by Tyco Fire Products. Na war-ranty, is given for products or components manufactured by compa-nies not affiliated by ownership with Tyco Fire Products or tar products and components which have been subject to misuse, improper installation, corro- sion. Or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards 01 any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products lobe defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as-sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT. TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WA RRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (specify SIN), (specify K-Fac- tor), (specify temperature rating), (specify Pendent or Upright) Extended Coverage Sprinkler With (specify fin- ish). P/N (specify - from Table E. where applicable). Recessed Escutcheon, Specify: Style (specify 30 or 40) Re- cessed Escutcheon with (specify fin- ish). PIN (specify). Style 30 Recessed Escutcheon Cn,nmn ptolod ............P55 541.705-9-err white Color Coo Ed ........ PsN se-ron-u-err Wtrila lROt.uerOf' .........P55 50-705-3-e11 O.aus Plated .............. P5w 50-705.2.e11 Style 40 Recessed Escutcheon ChronreRated ............ P5556.700.e.ert White Cuter Coated ........Poll 56.700.4-ett White /euLen1or .........P55 se-loo-3-e10 noun Plated ..............PuN 10-700-2-010 Eastem Hemisphere soles only Sprinkler Wrench: Specify: W-Typo 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprin- kler Wrench, PIN 56-665-7-001 P/N 51 - AAA - B -CCC AAA = 893 (for TY5237 Kit .2 Pendent) AAA = 884 (for TY5137 Ki 12 Upright) AAA = 895 (for TY6237 K14.0 Pendent) AAA =896 (for TYE137 514.0 Upright) B = 1 (for Natural Brass) B = 3 (tOt White )RALBOiOD B = 4 (for White Polyester) B = 7 (for Lead Coated B = 9 (for Chrome Plated) CCC = 135 (for 135-17/5rC) CCC = 155 (for 155FI68C) CCC = 175 (for 175F(79-C) CCC = 200 (for 200117/931C) Easiem Hemisphere sates only. TABLES PART NUMBERS FOR SC-il AND EC-14 SPRINKLERS TYCO FIRE PRODUCTS. 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: Has a Corrosion Resistance Ratio of 1.0 Has a Pressure Rating of 300 psi Is Lighter Weight Than Schedule 40 Is Approved by Factory Mutual and Listed by Underwriters Laboratories Is Produced in Accordance to ASTM A-135 and A-795 Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves Is Produced From Steel With Excellent Properties of Strength and Threadability Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS ILE SIZE 1.461 rni* 70 11/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE I•I mIs ml. 11/4 1.00 1.00 11/2 1.00 1.00 2 1.00 1.00 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, 6 Chesterfield, MO 63017 contact your salesperson today at C®uS (800) 325-4467 (800) 325-4467 or (636) 537-2600 LISTED BU MOOSE BE COMPANY FAX: (636) 537-2645 in the USA, or from Canada _______ www.bullrnoosetube.com call (800) 882-4666 A CAPHR company e-mail:sales@bLlllmoosetube.com <i~> APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the light to change product specifications without notice and without incurring obligation 8/08 Fig. 200 - "Trimline" Adjustable Band Hanger Size Range 1/2" thru 8" pipe Material - Carbon Steel, MU. Galvanized to G90 . .. specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features (1/2" thrLl 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily : A installed around pipe. (21/' thru 8" Spring tension on nut holds it securely in hanger before installation, Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel P'- 2 1.2 1 HN,.1 . N1H P11 F and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650F Finish - Mu. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200WON. Order By - Figure number and pipe size Dimensions Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/ 21/s 400 11 3/4 3/8 8mm or 10mm 3/8 21/ 400 11 1 3/8 8mm or 10mm 33/s 211a 400 12 1/4 3/8 8mm or 10mm 33/4 2 /8 400 13 1'/? 3/8 8mm or 10mm 37/s 21/8 400 14 2 3/8 8mm or 10mm 41I 3 400 15 - 2'/2 3/8 10mm 5 /8 4'Is 600 27 3 3/8 10mm 51/s 4 600 29 31/4 3/8 10mm 7 /8 5'14 600 34 4 3/8 10mm 7-1/a 5 1000 35 5 1/2 12mm 91/4 61/4 1250 66 6 1/2 12mm 101/ 6/4 1250 73 8 1/2 12mm 131/ 8/4 1250 136 Main Office/Manufacturing Facility 13P, '1n1p'.3n AVI • (l'-3. (A q:p • ii /I 9'1 • rr /1/ I Customer Ser'jice wwwto!cacom Fig. 98 - Rod Stiffener Size Range Secures 3/8 thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Finish - Electro Galvanized Note Available in HDG finish or Stainless Steel materials. Order By - Figure number Thread Rod Cut to Length n 3/8" thru 7/8' rod in 1" incrTTTnts Material - Carbon Steel Maximum Temperature - 750"F Finish Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -- Figure number, rod diameter, rod length and finish Dimensions Weights Rod Max. Rec, Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/ 8000 7140 360 11/2 11630 10370 510 Main Office/Manufacturing Facility l/0 0ni-1piiA.i c•n. 06i 920/0' ro oo.9 /2/ 9990 r.. rog /2/7210 Customer Service• /0/3 WWWto1co.com P.O. Box 3365 South El Monte, CA 91733 626444.0541 Fax 626.444.3887 www. Afcon.org P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 162 REVERSIBLE UNIVERSAL BEAM CLAMP 3/4" MOUTH RESTRAINING STRAP Nat optional, if insufficient rod dimension SIZE - 318" and 1/2 rod. MATERIAL - Ductile iron. FINISH - Plain, E.G. and H.D.G. LISTINGS - r\Zb'as 203-EX 2551 <S> Approval guide- Pipe Rangers FUNCTION. Hanger assembly attachment to steel flange with thitkness of less than 3/4". INSTALLATION - Per NFPA 13 with set screw up or down. Torque - 3/8"= 60 inch lbs. or 1/2" 125 inch tbs. In the absence of a torque wrench, engage Set bolt finger tight then additionally tighten 1/3 turn. FEATURES Listings allow installation with set screw up or down - see drawings. Maintains CONSTANT RANGER CENTER-LINE, with set screw up or down. Flat throat back to prevent twisting on flange during installation. ORDERING - Part #, rod size and finish. SIZE- One size fits both 3/8" and 1/2" rod or set screw. Available lengths 4" and longer. MATERIAL- Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - c1.!s),n 203-EX 2551 PATENT - No. 5,897,088 FUNCTION - To enhance hanger attachment in areas subject to Earthquakes. INSTALLATION - Install tight to structure and component parts Minimum return on strap: I" L.dimension is measured from hanger rod center to the strap end. FEATURES Fast installation for new construction or retrofit "Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component parts. (See drawings provided) ORDERING - Part 8 and L-dimension. 1/08 1/08 EX, VIM) WOOD) 8007957 GST 10 8020957 SWG 10 8008957 GST 20 8068925 GST 20 SS 8010957 GST 30 8009925 GST 25-380 8022925 SWG 25-380 8021957 SWG 20 8073925 SWG 20 SS 8139957 SH GST 2O 8141957 SH GST 3O 8140957 SH GST 2OSS 8142957 SH GST 30 SS !M!M MihThiiir FMI PipeSj Lc1i ua1sj UL S i ze~,.0 LoatI X CPVC1-1/2 300 1.5 X CPVC1-1/2 300 1.5 X 2-1/2 850 1.5 X 2-1/2 850 1.5 X 4 1500 1.5 X 4 1500 1.5 X 3-1/2 - 4 1500 1.5 X 2-1/2 3** 1250 1.5 X 2-1/2 1250 1.5 X 3 1050 1.5 X 4 1500 1.5 X 3 1050 1.5 X 4 1500 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 iffimufn P/N STEEL UL UL Max Pipe ULlest StI FM FM Max FM T.est Mini MOTR - - - -- Stetf Size, in. Load 1 A 4 1b0U 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 I B)( P/N CONCRETE FM FM Max FM Test Material L Pipe Stze Load U1.)f L,I LV A 4 1475 3000 PSI 8061957 SWC20 X 4 1475 3000P51 * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4' ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" ,7r7BuIIdex UL and FM tests were performed in compliance with NFPA-13 Standards. www.itwbuildex.com Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds, 800-284-5339 SSS26 MECHANICAL TEE The Shurjoint hole-cut mechanical tee provides a fast and easy mid-point branch outlet without welding. First a hole is cut or drilled at the desired outlet location. The mechanical tee is then positioned so that the built-in locating collar fits within the hole. As the housing bolts are tightened the pressure moulded gasket forms a leak-tight seal. Use of the Shurjoinf mechanical tee can eliminate the need for multiple couplings and fittings. Shurjoint offers a full range of mechanical tees: Model 7721: Threaded outlet, NPT or BS21 (ISO-7) pipe threads Model 7722: Cut-grooved outlet (machined) Model 723: Saddle-Let; Small mechanical tee with threaded outlet, NPT or BS21 (ISO-7) pipe threads MECHANICAL CROSS A mechanical cross connection can be made by combining two mechanical tee upper housing segments. While the housing segments must be the same size, the branch outlets can be of the same or differing sizes or configurations. Threaded x Threaded Grooved x Grooved Threaded x Grooved (Model 7721+7721) (Model 7722+7722) (Model 7721+7722) Caution: Piping practices require that main and branch connections are at a true 90 angle. Also be certain that the locating collar is securely positioned inside the outlet hole before tightening the hous- ing. When mechanical tees or mechanical crosses are used as transi- tion pieces between two runs, the tees or crosses shall be assembled prior to making the branch connections. MODEL 723 SADDLE-LET (Small Mechanical Tee) The Model 723 Saddle-Let is the ideal outlet fitting for direct connections to sprinkler heads, drop nipples and or gauges. No need for welding, just cut or drill a hole at the desired outlet loca- tion. Position the Saddle-Let so that the locating collar fits within the hole and secure with the U-bolt and nuts. The Saddle-Let comes with a standard black finish or as an option can be supplied electro zinc plated or painted orange. The Saddle-Let allows full bore flow and is pressure rated to 300 psi (20 bar). c®us FM W LISTED R APPROV I-Size; 4 •Q/+O.ob uj . i B C . ' *4/Lb-' 32 x 15 30 53.0 89.0 56.0 35.0 1-1/20 20-30 04 4.25A.0.5., 1.18 . 2.08 3.50 2.20 1.38 . U-Bolt 15-22 0.9 32 x 20 30 53.0 69.0 56.0 35.0 1-1/20 20 - 30 0.4 1.25'x 075 118 ._-ZOV 3.50 2.20 138 . U-Bolt 15-22 0.9 32 x 25 30 560 89.0 56.0 38.0 11120 20-30 0.4 1.25 x 1 - V18 , 2.2P 3.50 2.20 1.50 U-Bolt 15-22 0.9 40 x 1 30 55.0 89.0 56.0 35.0 1-1/26 20-30 0.4 15 e0.5 1.18 - •- ' ' 2.16 3.50 2.20 138 U-Bolt 15-22 0.9 40 20 30 55.0 89.0 560 35.0 1-1/20 20-30 04 1.5 x0;75 1.18, .216 - 3.50 2.20 1.38 U.-Bolt 15-22 0.9 40x 25 30 58.0 89.0 56.0 38:0 • 1-1/2 20- 30 0:4 1.18 3.50 2.20 1.50 U-Bolt 15-22 0.9 50 x 15 30 64.0 98.0 • 560 42.0 20 20 30 04 2'i 0.5 • 1.18 ' 251 - - 3.85 2.20 1.65 U-Bolt 15-22..0.9 50 x 20 30 64.0 98.0 -56.0 42.0 2 20-30 04 2'x 0.75 1.18 251 3.85 2.20 1.65 U-Bolt 15-22 0.9 50 x 25 30 67.0 98.0 56.0 450 20 20-30 0.4 1.18 - 2.63 3.85 2.20 1.77 U-Bolt 15-22 - 0.9 65x 15 30 69.0 111.0 56.0 51.0 2-1/20 20-30 0.4 25'x 0 5. ' - 1.18 2.71 4.37 2.20 2.00 U-Bolt 15 -22 09 - 65 x 20 30 69.0 111.0 56.0 51.0 - 2-1/20 20-30 0.4 2.5 x 0.75 . 1.18 . 2.71 4.37 2.20 2.00 U-Bolt 15-22 0.9 65 x 25 30 72.0 1110 56.0 540 - 2-1/20 20 -'30 • 0.5 - - '1.18 2.83 4.37 2.20 2.13 U-Bolt 15-22 1.1 28 - rT-, QUY TD T(u1Jrr®