Loading...
HomeMy WebLinkAbout3335 VENADO ST; ; AS110022; Permit10/5/22, 3:52 PM AS110022 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS110022 Job Address: 3335 VENADO ST Permit Type: SPRINK Parcel No: 2232500500 Lot #: 0 Reference No.: Status: ISSUED Applied 2/16/2011 Approved: 2/16/2011 Issued: 2/16/2011 PC #: Inspector: Project Title: STEVENS GUEST HOUSE RESIDENTIAL SPRINKLER PLAN CHECK & INSPECTIONS Applicant: METRO FIRE 2735 VIA ORANGE WY SPRING VALLEY, CA 619-670-3500 Owner: STEVENS PAUL J&LAWSON MELANIE A 3335 VENADO ST CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 260 0 260 0 about:blank 1/1 4. HRS SYSTEMS, INC 208 South Public Square Petersburg, TN 37144 HYDRAULIC CALCULATIONS FOR STEVENS GUEST HOUSE DATE: 2-10-11 -DESIGN DATA- REMOTE AREA NUMBER: 1 REMOTE AREA LOCATION: LIV/BED ROOM OCCUPANCY CLASSIFICATION: RESIDENTAIL 13D DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 2 HEADS COVERAGE PER SPRINKLER: 16' X 16' TYPE OF SPRINKLERS CALCULATED: 4.9 NUMBER OF SPRINKLERS CALCULATED: 2 HOSE-STREAM DEMAND: 0 gpm TOTAL WATER REQUIRED (INCLUDING HOSE) : 26.1 gpm FLOW AND PRESSURE (AT BASE OF RISER): 26.1 gpm 8 17.1 psi TYPE OF SYSTEM: WET INSTALLING CONTRACTOR Name: METRO FIRE SAFETY Address: 2753 ViA ORANGE WAY, SPRING VALLEY, CA 91978 Phone: 619-760-3900 Certification number: C-16 909203 NAME OF DESIGNER: FRANCOT DAVIS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT. Items listed in bold print are automatically transfered from the calculation report SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 2/10/2011 C:\PROGRAN FILES\HRS SYSTEMS\HASS81\STEVENS RES.SDP JOE TITLE: STEVENS GUEST HOUSE W AA a n s I e szclw t€e SQ es teui UT 0 P 5 0 MQ frJ fl T 70 7/7 -r 0 0 0 0 0 0 B - 1i S SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 2/10/2011 C:\PROGRAM FILES\HRS SYSTEMS\HASS81\STEVENS RES.SDF JOB TITLE: STEVENS GUEST HOUSE NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ!D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 135.0 130.0 30.0 131.1 26.1 29.9 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (PT) (PSI) (GPM) 1 8.5 K= 4.90 7.0 13.0 2 8.5 K= 4.90 7.1 13.1 3 8.5 - - - - 7.6 - - - TOR 8.5 - - - - 11.2 - - - BOR 1.0 - - - - 17.1 - - - SRC 1.0 SOURCE 29.9 26.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 2/10/2011 C:\PROGRAM FILES\HRS SYSTEMS\HASS81\STEVENS RES.SDF JOE TITLE: STEVENS GUEST HOUSE Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 4.90 13.0 Disch 17.00 150 0.5 3 8.5 7.6 0.0 1.000 ---- 0.00 0.0 1 8.5 7.0 13.0 1.101 17.00 0.031 0.5 Pipe: 2 4.90 13.1 Disch 14.00 150 0.4 3 8.5 7.6 0.0 1.000 ---- 0.00 0.0 2 8.5 7.1 13.1 1.101 14.00 0.031 0.4 Pipe: 3 0.0 0.0 33.00 150 3.7 TOR 8.5 11.2 26.1 1.000 ---- 0.00 0.0 3 8.5 7.6 26.1 1.101 33.00 0.111 3.7 Pipe: 4 0.0 0.0 7.50 120 5.9 BOR 1.0 17.1 26.1 3 1.000 C: 5.0 5.00 -3.2 TOR 8.5 11.2 26.1 1.049 12.50 0.213 2.7 Pipe: 5 Source 0.0 115.00 150 12.8 SRC 1.0 29.9 26.1 TOR 1.000 ---- 0.00 0.0 BOR 1.0 17.1 26.1 1.101 115.00 0.111 12.8 NOTES (HASS) Calculations were performed by the HASS 8.1 computer program under license no. 38020412 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.011 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 9.7 ft/sec at pipe 4. Notes