Loading...
HomeMy WebLinkAbout7625 VIA CAMPANILE; 122; FPC2018-0100; PermitPERbilT REPORT CCICity of Carlsbad MFD Print Date: 10/05/2022 Permit No: FPC2018-0100 Job Address: 7625 VIA CAMPANILE, U 122, CARLSBAD, CA 92009-8489 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel U: 2230531200 Track U: Applied: 03/28/2018 Valuation: $73,716.08 Lot U: Issued: 04/10/2018 Occupancy Group: Project U: Finaled Close Out: 04/15/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Plan Check U: Project Title: Description: JERSEY MIKES -SPRINKLER MONITORING FPContractor: HUNTINGTON SECURITY SYSTEMS INC 2681 DOW AVE. 1* STE B TUSTIN, CA 92780-7244 (714) 389-7683 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 1 I www.carlsbadca.gov Revision #4 Tenant Improvement Installation Company: 6 I Huntington SectuiSecurity Systems, Inc. tv~4. I 2681 Dow Avenue, Suite B Tustin, CA. 92780 (800) 559-1929 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with ULs requirements is The issuance of a UL Certificate for the Alarm System and the Certificate is current Under IJLs Certificate Verification Service. This Certificate does not apply in anyway to the communication channel between theprotected property and any facility that monitors signals from the prOtected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. - Listed Service From: CYPRESS, CA (CYPRESS) Alarm Service Company (100032-80411. Service Center (100032-804) SECURITY MONITORING SERVICES INC, DBA SECURITY MONITORING SERVICES INC. DBA CRITICOM MONITORING SERVICES CRITICOM MONITORING SERVICES SUITE 200 SUITE 200 11130 HOLDER ST 11130 HOLDER ST CYPRESS CA 90630 CYPRESS CA 90630 The Alarm Service Company IsLisled in-the followlngteftmcate Service Categories: File - Vol No. CCN Listing Category P S30722 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station THIS CERTIFICATE EXPIRES ON 31MAR2018*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" DF52418B A120 MS09050UD(E) Fire tietarms Fire Alarm Control Panel with DACT by Honeywell - ' - General The FireuLite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- sive list of powerful features, the MS-9050UD programs just like Fire-Lite's larger products, yet fits into applications previously - -- served only by conventional panels. The MS-9050UD's integral DACT. transmits system status - (alarms, troubles, AC loss, etc.) to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload! Download utility. In addition, the control panel may be pro- . grammed or. interrogated off-site via the public switched tele- phone network. Any personal computer with Windows 95 or greater, and compatible modem with a speed of 14.4 kbps or . . •faster and Fire-Lite Upload/Download software kit PK-CD, may -' - serve as a Service Terminal. This allows download of the entire •• program or upload of the entire program, history file, walktest Point trouble identification. data, current status and system voltages. The power supply and all electronics are contained on a single Waterf low selection per module point. circuit board supported on a new quick install chassis and Alarm verification selection per detector point. housed in a metal cabinet. Available accessories include local Maintenance alert warns when smoke detector dust accumu- and remote upload/download software, remote annunciators, lation is excessive. and reverse polarity/city box transmitter. (4XTMF) One-person audible or silent walk test with walk-test log and New options include a UL listed printer, PRN-6F and the new printout. IPDACT Internet Monitoring module. The FireWatch Series System alarm verification selection per detector point. internet monitoring modules IPDACT-2 and IPDACT-2UD permit PAS (Positive Alarm Sequence) and Pre-signal per point monitoring of alarm signals over the Internet saving the monthly (NFPA 72 compliant). cost of two telephone lines. Although not required, the second- Up to eight ANN-BUS annunciators ary telephone line may be retained providing backup communi- cation over the public switched telephone line. Remote Acknowledge, Alarm Silence, Reset and Drill via NOTE; Unless otherwise specified, the term MS-9050U0 is used addressable modules or remote annunciator. in this data sheet to refer to both the MS-9050UD and the Ms- Upload/Download (local or remote) of program and data via 9050 UDE FACP5. For MS-905OUDC, refer to DF-60445. integral DACT. Features SLC COMMUNICATION LOOP Single addressable SLC loop which meets NFPA Style 4, 6 Listed to UL Standard 864, 9th edition. and 7 requirements. Auto-program (learn mode) reduces installation time. 50 addressable device capacity (any combination of address- Reports two devices set to the same address. able detectors and modules). On-board DACT. Compatible with Fire-Lite's addressable devices (refer to SLC Two independently programmable Style Z (Class A) or Style Wiring Manual). Y (Class B) NAC circuits. NOTIFICATION APPLIANCE CIRCUITS (NACS) Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. Two indepe idently programmable output circuits. Circuits Remote Acknowledge, Silence, Reset and Drill via address- can be configured for the following outputs: able monitor modules. - Style Y (Class B) Two programmable relays and one fixed trouble relay. Style Z (Class A) Built-in Programmer. - Door Holder Service (cannot be used for notification appliances) Telephone Line Active LEDs. - Aux Power Source (cannot be used for notification appliances) ElA-232 PC interlace. Silence Inhibit and Autosilence timer options. Integral 80-character LCD display with backlighting. Continuous, March Time, Temporal or California code for Real-time clock/calendar with automatic daylight savings main circuit board NACs with two-stage capability. control. Selectable strobe synchronization per NAC. History file with 500 event capacity. •2.5 A total power for NACs. Automatic detector sensitivity testing (NFPA 72 compliant). NOTE. Maximum or total 24VDC sYs2te7mA Power shared between all NAC circuits and the ANN-BUS is• Automatic device type-code verification. DF-52418:B • 05/18/2009 - Page 1 of 4 PROGRAMMING AND SOFTWARE ) Autoprogram (learn mode) reduces installation time - Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 20 software zones. Continuous fire protection during online programming at the front panel. MS-9050U0 _______ Program Check automatically catches common errors not Fire Alarm linked to any zone or input point. Control Panel OFFLINE PROGRAMMING; Create the entire program in 0 ANN-80 your office using a Windows®-based software package • . (order programming kit P1<-CD, containing P1<-Plus, sepa- rately), Upload/download system. programming . locally to Printer the .MS-9050UD in less than one minute: . • Gateway . . . . User interface Photo Detector LED INDICATORS . .. . . C . Graphic LED . AC Power (green) . . •••_-. • . Module . . Fire Alarm (red) •. . . . . . . AD355 •• Supervisory (yellow) Adapt Detector . . . . . . . Trouble (yellow) . . ---- Relay Module Alarm Silenced signals. (yellow) . . . . . . KEYPAD ••. . . .. . .. . . .• . . . H355/H355R1H355H1 . . . . . . . . • 16 key, alpha-numeric pad . . . Heat Detector P2R Acknowledge/Step Strobe Alarm Silenced Drill (Manual Evacuate) -- Reset (lamp test) MDF-300 . Dual Monitor Module Product Line Information Power Supply Strobe MS-9050UD(E): Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, FCPS-24F58 k chassis with transformer, backbox with door, plastic bag contain- S0355T ing screws, cables, key, etc., manual. (For MS-9050U0C, refer Photo/Thermal to DF.60445.) P2R Se PK-CD: Contains PK-Plus programming software for Win- M dows®-based PC computer (cable not included). - Multi-Modules DP-51050: Optional dress panel for the MS-9050UD. Monitor Module CRF-300-6 Six-Relay Control Module TR-CE: Trim Ring for semi-flush mounting. CMF-300-6 Six-Circuit Supervised Control Module BB-6F: Optional cabinet for up to six modules mounted on MMF-302-6 Six-Zone Interface Module CHS-6 chassis (below). El MMF-300-10 Ten-Input Monitor Module BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. 2-Wire Detector BB-55F: Battery box, houses two 55 AH batteries Monitor Module ," CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. j CHG-75: Battery charger for lead-acid batteries with a rating of 25to75AH. D350PUD35ORPL Beam Detector BAT Series: Batteries, see data sheet DF-52397. Duct Detector BEAM-335/(S) PRT/PK-CABLE: Cable printer/personal computer interface cable. I MS-9050UD PRN-6F: UL listed compatible event printer. Uses tractor-fed I - ADDRESSABLE FIRE ALARM IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts - rtIrrrI nAv,Iri CONTROL flUL rMl'JCL in bottom of enclosure with optional mounting kit (PN IPBR1<T). BG-12LX Addressable Connects to primary and secondary DACT telephone output Manual Pull Station ports for internet communications over customer provided ether- net Internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df-52424 for more information.) Page 2 of 4— DF-52418:B • 05/18/2009 . IPBRKT Mounting kit for IPDACT2/2UD in common enclosure. MDF 300 Dual Monitor Module Same as MMF 300 except it IPSPLT Y adaptor option allows connection of both panel dialer Provides two Style B (Class B) only lDCs outputs to one IPDACT-2/2UD cable input. MMF-301: Miniatuje version of MMF-300. Excludes LED and AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in Style D option. Connects with wire pigtails. May mount in device turn, mounts to the FACP chassis. Use AC-TRMBLK when wire backbox. nuts are not allowed for AC connections to the transformer. MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC OPTIONAL MODULES power. Consult factory for compatible smoke detectors. 4XTMF Reverse Polarity Transmitter Module: Provides a CMF-300: Addressable Control Module for one Style Y/Z (Class supervised output for local energy municipal box transmitter, B/A) zone of supervised polarized Notification Appliances. alarm and trouble. Includes a disable switch and disable trouble Mounts directly to a 4.0 (10.16 cm.) electrical box. Notification LED. Appliance Circuit option requires external 24 VDC to power noti- COMPATIBLE ANNUNCIATORS ANN-80(-W):Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclo- sure. (See DF-60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Printer Gateway module pro- vides a connection for a serial or parallel printer. (See DF- 52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fast-response, low-profile heat detector that activates at 190°F/88°C. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (13350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sen- sitivity test. D350PL: Photoelectric low-flow duct smoke detector. D350RPL: Photoelectric low-flow duct smoke detector with relay option. MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0' (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull- station with interface mod- ule mounted inside. 1300: This module isolates the SLC loop from short circuit condi- tions (required for Style 6 or ,7 operation). SM13500: Used to mount all modules except the MMF-301 and M301. . MMF-300-10: Ten-input monitor module.. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet.. MMF-302-6: Six-zone interface module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9050U0, see the following data sheets (document numbers): AD355 (DF-52386), BG- 12LX (OF- 52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/ CAF Series (DF-52130), CP355 (DF-52383), D350PUD35ORPL (DF-52398), H355 Series (DF-52385), 1300 (DF-52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), S0355/50355T (DF-52384). ADDFIESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): 47k ohm supervises the MMF-300, MDF-300, MMF-301, and CMF- 300 module circuits. 3.9k ohm End-of-Line Resistor assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. DF-52418:13 • 05/18/2009 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- Intelligent Signalling Line Circuits ..... .................................... 1 nents may be adversely affected by extreme temperature ranges Addressable device capacity..............................................50 and humidity. Therefore, it is recommended that this system and • Programmable software zones ........................................... 20 its peripherals be installed in an environment with a normal room Annunciators .......................................................... ............... 8 temperature of 15— 27°C/60 - 80°F Electrical Specifications NFPA Standards AC Power: MS-9050UD 120 VAC, 60 Hz, 3.0 A. MS-905OUDE: The MS-9050UD(E) complies with the following NFPA 72 Fire Alarm Systems requirements: 240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. - LOCAL (Automatic, Manual, Waterflow and Sprinkler 'Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Supervisory). Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two - AUXILIARY (Automatic, Manual and Waterflow) (requires 18. AH batteries.) . . . . 4XTMF). Communication Loop: Supervised and power-limited. -REMOTE STATION (Automatic, Manual and Waterflow) .-REMOTE (Where a DACT is not accepted, the alarm, trouble and Notification Appliance Circuits: Terminal Block provides con- supervisory relays may be connected to UL 864 listed nections for two NACs, Style V (Class B) or. Style Z (Class A). transmitters. For reverse polarity signaling of alarm and Special. Application power. Power-limited, supervised circuitry. trouble, 4XTMF is required.). . . Maximum signaling current per circuit: 2.5 A. End-of-Line Resis- - PROPRIETARY (Automatic Manual and Waterflow tor: 4.7 kohm, ½ watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to the Fire•Lite Device Compatibility Document for , - CENTRAL STATION (Automatic, Manual and Waterflow, listed compatible devices. . and Sprinkler Supervised). Two Programmable Relays and One Fixed Trouble Relay: - OT, PSDN (Other Technologies,. Packet-switched Data Net- Contact rating: 2.0 A © 30 VDC (resistive), 0.5A © 30. VAC Work) (resistive). Form-C relays, nonpower-limited, nonsupervised. Agency Listings and Approvals Cabinet Specifications The listings and approvals below apply to the basic MS- Door: 19.26" (48M cm.) high x 16.82" (42.73 cm) wide x 0.72" 9050UD(E) control panel. In some cases, certain modules may (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" not be listed by certain approval agencies, or listing may be in (42.29 cm.) wide x 5.25' (13.34 cm.) deep. Trim Ring (TR-CE): process. Consult factory for latest listing status. 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. UL: S624 FM approved Shipping Specifications CSFM: 7165-0075:210 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00° (50.80 cm.) MEA: 442-06-E high x 22.5° (57.15 cm.) wide x 8.5",(21.59 cm.) deep. NOTE: See DF-60445 for ULC-listed model. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (non- FireLite® Alarms® and System Sensot® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. ir & MMIMMM1118 All specifications are subject to change without notice. QUALITY SYSTEMS . . Made in the U.S.A, For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com - Page 4 of 4— DF-52418:8 • 05/18/2009 A - Power Supply Calculations SECTION 7 Power Supply Calculations 7.1 Overview This section contains instructions and tables for calculating power supply currents in alarm and standby conditions. This is a four-step process, consisting of the following: 1. Calculating the total amount of AC branch circuit current required to operate the system I Calculating the power supply load current for non-fire and fire alarm conditions and calculating the secondary (battery) load 3. Calculating the size of batteries required to support the system if an AC power loss occurs 4. Selecting the proper batteries for your system 7.2 Calculating the AC Branch Circuit The control panel requires connection to a separate, dedicated AC branch circuit, which must be labeled FIRE ALARM. This branch circuit must connect to the line side of the main power feed of the protected premises. No other non-fire alarm equipment may be powered from the fire alarm branch circuit. The branch circuit wire must run continuously, without any disconnect devices, from the power source to the control panel Overcurrent protection for this circuit must comply with Article 760 of the National Electrical Codes as well as local codes. Use 14 AWG (2.00 mm2) wire with 600 volt insulation for this branch circuit. Use Table 7.1 ,to determine the total amount of current, in AC amperes (A), that must be supplied to the system. Table 7.1 AC Branch Circuit Requirements Device Type Numberof Current Draw Total Current Devices (AC amps) per Device MS-9050UD 3.0 or I X or = MS-905OUDE 1.5 X [ ] = Sum Column for AC Branch Current Required = MS-9050UD Series PN 52413:D 2/I5/08 179 The control panel must be able to power all internal and external devices continuously during the non-fire alarm condition. To calculate the non-fire alarm load on the system power supply when primary power is applied, use Calculation Column I in Table 7.3 on page 181. The control panel must support a larger load current during a fire alarm condition To calculate the fire alarm load on the power supply, use Calculation Column 2 in Table 7.3 on page 181. The secondary power source (batteries) must be able to power the system during a primary power loss. To calculate the non-fire alarm load on the secondary power source, use Calculation Column 3 in Table 7.3 on page 181. When calculating current draw and the battery size, note the following 'Primary' refers to the main power source for the control panel Secondary refers to the control panel's backup batteries All currents are given in amperes (A) Table 7.2 shows how to convert milliamperes and microamperes to full amperes. : Table 7.2 Converting to Full Amperes To convert.- Multiply Example Milliamperes (mA) to amperes (A) ,A x 0.001 3 mA x 0.001 = 0.003A Microamperes (xA) to amperes (A) 0.000001 300 .tA x 0.000001 = 0.0003 A 7.3.2 How to Use Table 7.3 on page 181 to Calculate System Current Draw Use Table 7.3 on page 181 to calculate current draws as follows: Enter the quantity of devices in all three columns Enter the current draw where required. Refer to the Fire-Lite Device Compatibility Document for compatible devices and their current draw Calculate the current dinws for each in all columns Sum the total current for each column Copy the totals from Column 2 and Column 3 to Table 7.4 on page 182 Following are the types of current that can be entered into Table 7.3 on page 181: / Calculation Column 1 - The primary supply current load that the control panel must support during a non-fire alarm condition, with AC power applied. / Calculation Column 2 - The primary supply current load that the control panel must support during a fire alarm condition, with AC power applied. / Calculation Column 3- The standby current drawn from the batteries in a non-fire alarm condition during a loss of AC power. 180 MS-9050U1) Series PN 52413:D 12/15/08 Power Supply Calculations Table 7.3 contains columns for calculating current draws For each column calculate the current and enter the total (in amperes) in the bottom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 182. Table 7.3 System Current Draw Calculations Calculation Column I Primary, Non-Fire Alarm Current Device Type (amps) Calculation Column 2 Primary, Fire Alarm Current (amps) Calculation Column 3 Secondary, Non-Fire Alarm Current (amps) Qty X[current draw]= Total Qty X current draw] = Total Qty X(current draw]= Total Main Circuit Board Xl0.1201 0.120 1 X[O.2001 0.200 1 XIO.120] 0.120 4XTMF ] X0.005]= [ I X10.01111= F ] X[0.005]= 4-wire Detector Heads F I X( 12= [ ] X1 1= X( ] Power Supervision I xlo.0251= Reiays3 ________________ I ] XIO.0251= __________________________________ [ X[O.0251= ___________________________ CP350 & CP355 - X[0.00030]= . . Ij5'm0m alarm draw 0400 for all devices ________________________________ X0.00030]= SD350 & m)-i55 it - X 0.000301= - [ - X(0.00030]= SD33OT & SD355T - J X 0.00030]- 1 J X[0.00030]= A0350 & AD355 X[0.00030]= - J X[0.00u3o= H350 & H355 - X[0.00030]= - [ - X[0.00030]= - H350R & H355R 1-I X[0.00030]= - - X[0.00030]= H355411 t X[0.00030]= - -I X[0.000301= D350P -j XLO.00030}= - 1 X0.00030J= D35ORP - X[0.00030]= = X[0.00030]= B501Bil&B501BH14 1] X[0.001] j X0.001]= B224RB Relay Base - X[O.00050]= - - XIO.00050 B224Bi Isolator Base - X[0.00045] - - X[o.00045 = MMF-300 X0.000401= X[0.00040]= MMF-30070 - XIQ.003501 XIO.00350]= MD11-300 -j I X[0.00075]= - - XIO.00075]= MMF-30i X[0.0003751= I -i X(0.000375]= MME-302 X[0.00027]= - X[0.00027]= MMF-302-6 - t X[0.00200j= - XIO.00200]= BO-I2LX - X[0.00023]= - - X[O.00023]= CMF-300 1 X[0.00039]= [] X[0.00039]= CMF-300-6 1 X[0.00225]= - - XLO.00225]= CRF-300 Xl0.00027]= CRF-300-6 - Xl0.00i45]= - - X[0.00i45j= 1300 11 X[0.000401= r- X[0.000401= ANN-So XIO.0370]= 1 1 X[0.0400]= ANN-lb I X[0.0350]= [_J X[0.2000= ANN-RLY -) X[0.0150]= I I X[0.0750]= - - Xl0.01501= ANN-(R)LED 1) X[0.0280}= I ] X[0.0680J= - X[0.0280]= ANN-SIPO 1) X[0.0450]= NAC#I' NAC#2 Sum each columns for totals Primary Non-Alarm = I J X[0.0450J= } X( ]= I 31 ]= Primary Alarm Secondary Non-Alarm Table Footnote If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. Refer to the Device Compatibility Document for standby current. Must use compatible listed Power Supervision Relay. Maximum alarm current for each sounder base is 0.015 amps which must be supplied by aux. 24VDC source. Current limitation of Terminal TBI circuits is 2.5 amps total max. Total current draw listed above cannot exceed 2.7 amps. * MS-9050UD Series PN 52413:1) 12/15/08 181 Power Supply Calculations 74 Calculating the Battery Size Use Table 7.4 to calculate the total Standby and Alarm load in ampere hours (AH). This total load determines the battery size (in AH), required to support the control panel under the loss of AC power. Complete Table 7.4 as follows: Enter the totals from Table 7.3 on page 181, Calculation Columns 2 and 3 where shown Enter the NFPA Standby and Alarm times (refer to 'NFPA Requirements' below) Calculate the ampere hours for Standby and Alarm, then sum the Standby.and Alarm ampere hours Multiply the sum by the derating factor of 1.2 to calculate the proper battery size (in AH) Write the ampere hour requirements on the Protected Premises label located inside the cabinet door Table 7.4 Total Secondary Power Requirements at 24 VDC Secondary Standby Load Required Standby Time (total from Table 7.3 Calculation (24 hours) Column 3) AR Primary Alarm Load Required Alarm Time (total from Table 7.3 Calculation (for 5 min., enter 0.084, Column 2) for 10 mm., enter 0.168) X[ } = AH Sum of Standby and Alarm Ampere Hours = Al-I Multiply by the Deratung Factor X 1.2 Battery Size, Total Ampere Hours Required I = AH 7.4.1 NFPA Battery Requirements NFPA 72 Local and Proprietary Fire Alarm Systems require 24 hours of standby power followed by 5 minutes in alarm NFPA 72 Central, Auxiliary and Remote Station Fire Alarm Systems require 60 hours of standby followed by 5 minutes in alarm. Batteries installed in a system powered by a generator need to provide at least 4 hours of standby power 7.4.2 Selecting and Locating Batteries Select batteries that meet or exceed the total ampere hours calculated in Table 7.4. The control panel can charge batteries in the 7 AH to 18 AH range. The control panel cabinet is capable of housing batteries up to 18 AH. Batteries larger than 18 AR require a UL listed external battery charger and cabinet such as the BB-26, BB-55F or other UL listed external battery cabinet. 182 MS-9050U1) Series PN 52413:D 12/15/08 ' - Notification Appliance Special Application Power Basic System Connections NAC 91 Shown Style Y (Class 8) (Power-ljmited, Class 2, Supervised) NAC #2 Shown Style Z (Class A) (Power-Limited, Class 2, Supervised) EIA-232 to 2.5 amps max. per circuit. Total available current 2.5 ampe personal computer NAC #1 ELR 4.7K, v.w NAC #2 2 Programmable Relays & personal computer with FACP 1 Fixed Trouble Relay Uplosd/DonJoad Utility. + 50 foot maximum within same room. Nonsupervised Contact Ratings* (Nonsupervised, ZO amps @30 VDC (resistive) -Power-limited (Class 2) Circuit) 0.5 amps @30 VAC (resistive) + SLC Loon + Contacts shown below In normal Refer to the SLC Wiring condition (AC power with no alarm, Manual for detailed trouble or supervisory activity). ç Information on wiring addressable devices A Fail Safe Trouble NC NO C 0 0 0 OJ - -Mile (p + + for Style 4,6 and 7. relay switches to Bie - NO position during 6 0 or Red, (Power- Limited, Class 2 Gr trouble conditions and ANN-BUS (EIA-465) for - een Supervised Circuit) under loss of all power. Annunciator 4- Black (Factory default relay programming) Connection (p id flflflflflfl Class 2 Alarm Trouble Supervisory Supervised) Ii1 I Per specific UL wiring information, refer to UL Power-limited Wiring Requirements* on page 46 FO 757 TB3 JP2 JL_-...--- Remove this jumper to enable 4XTMF Cut JP28 to / Siervisory relay when is - suvise • 4X1 MF module is installed ) 4 F aeniown .14 is O is noENABLE EMSPV RELAY .1311111.51) lUll)) II 111511 JPI To disable ground fault detection, LCD DISPLAY remove jumper/shunt from JP1 1 . rD 41 tA 00 I U U Char (cut tO disable FACP _____ __ !• t' SW' 5RAsHMEaORYLOIS onboerd battery charger) a -. A KISSOFF LED3IaLED2IB L]'J BLEd SJKL • RY 4431,11 Transformer ______________________ ACTIVE ACTIVE Connector - Supervised Nonpower-limited, I61 I 5011* 5 CAUTIONI ° U a HIGH VOLTAGE BATTERY reyswe. PHi P142 Battery PS2 Keyboard Interface DACT Phone Line Jacks 24 VOC, nonpower-limlted, (non r4imited. supervised, 18 Amp Hour max. lJ - - - ERpervised) A El LUL 00 Do 11 ANN 1/0 _jMML N ANN-80 ANNS/PG Text Annunciator LED Driver Doc. #151416 Printer Driver Doe. #52749 O . Doe. #151417 1PDACT ANN-BUS Internet Protocol Communicator / Doc. #53109 PHI&PH2 Telephone 00 ) • :l - I 4XTMF Municipal Box Transmitter SLC Loop r L'- Addressable Devices and SLC Wiring Doc. #51309 Local PC , Battery Connector - - IeI ODDODO - - - CIIG-120F Charger CUG-75 Charger Doe. #50888 Doe. #51315 MS-9050UD Series PN 52413:D 12/15/08 LISTING No. 7165-0075:0210 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email vladimir..kireyev@Honeywell.com DESIGN: Model MS-9050UD addressable fire alarm control unit. Unit consists of one communication loop, two bell circuits, and three relay contact outputs for alarm, trouble and supervisory. Local auxiliary remote station central station and proprietary (protected premise) automatic manual water flow and sprinkler supervisory service Refer to listee's data sheet for detailed product description operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING 120 VAC 60 Hz 3.0 A Primary, 24 VDC Secondary. INSTALLATION: In accordance with listee's printed installation instructions, applicable Codes and ordinances • and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 07-07-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF521210 E325 MMF.300(A) Series, We IITUALarms MDF300 Addressable Monitor Modules by Honeywell r 1 I '. y General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4° [10 16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3 (3.302 cm) H x 2.75" (6.985 cm) W x 0.5' (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MM F-301 (A) to be mounted in a single-gang box behind the device it monitors; MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to MMF-300(A) (Type H) monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two may be wired as an NFPA Style B (Class B) or Style .D (Class separate, consecutive addresses in intelligent, two-wire systems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor LiteSpeedTM is a communication protocol developed by (provided) terminates the Style B circuit. No resistor is Fire-Lite Engineering that greatly increases the speed of com- required for supervision of the Style D circuit. munication between analog intelligent devices. Intelligent MMF-300(A) OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status (open/nor- other communication protocols. mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control MMF-300(A) Monitor Module panel. The LED latches steady on alarm (subject to current limitations on the loop). Built-in type identification automatically identifies this device as a monitor module to the control panel. MMF300(A) SPECIFICATIONS Powered directly by two-wire SLC loop. No additional power Nominal operating voltage: 15 to 32 VDC. required. Maximum current draw: 5.0 mA (LED on). High noise (EMF/RFI) immunity. Average operating current: 350 pA (LED flashing), 1 corn- SEMS screws with clamping plates for ease of wiring. munication every 5 seconds, 47k EOL. Direct-dial entry of address: 01 - 159 on MS-9600 series Maximum IDC wiring resistance: 1500 Ohms. panels, 01 - 99 on other compatible systems. EOL resistance: 47K Ohms. LED flashes during normal operation and latches on steady to indicate alarm. Temperature range: 32°F to 120°F (0°C to 490C). The MMF-300(A) Monitor Module is intended for use in intelli- Humidity range: 10% to 93% noncondensing. gent, two-wire systems, where the individual address of each Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x module is selected using the built-in rotary switches. It pro- 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x vides either a two-wire or four-wire fault-tolerant Initiating 2.125" (5.398 cm) deep box. Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) MMF.301 (A) Mini Monitor Module modules in existing systems. • Built-in type identification automatically identifies this device MMF-300(A) APPLICATIONS as a monitor module to the panel. Use to monitor a zone of four-wire smoke detectors, manual Powered directly by two-wire SLC loop. No additional power fire alarm pull stations, waterf low devices, or other normally- required. open dry-contact alarm activation devices. May also be used • High noise (EMF/RFI) immunity. to monitor normally-open supervisory devices with special • Tinned, stripped leads for ease of wiring. supervisory indication at the control panel. Monitored circuit DF-52121:D.O1/20/2015— Page l 0t4 - : Direct-dial entry of, address: 01 - 159 oh MS-9600 series • Supervises IDC. wiring and connection of external power• panels, 01 - 99 on other compatible systems source.. - : -- ___________________________________ • High noise (EMF/RFl) immunity. 1415 0 1 ADDRESS I 0 1 • SEMS screws with clamping plates for ease of wiring. 1\2 • Direct-dial entry entry of address: 01 - 159 on MS-9600 o2 LOOP LED flashes during normal operation. • series panels, 01 - 99 on other compatible systems. 11 8 6 0~~ 8 • LED latches steady to indicate alarm on command from TENS ONES control panel. The MMF 302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- __J open, or alarm) of one full zone of conventional detectors fl back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF- 302(A) can be used to. replace M302(A) modules in existing systems. MMF-302 (A) APPLICAIiONS The MMF-301(A) Mini Monitor Module can be installed in a Use the MMF-302(A) to monitor a zone of two-wire smoke single-gang junction directly behind the monitored unit. Its detectors. The monitored circuit may be wired as an NFPA small size and light weight allow it to be installed without rigid Style B (Class B) or Style ,D (Class A) Initiating Device Circuit. mounting. The MMF-301(A) is intended for use in intelligent, A 3.9 K Ohm End-of-Line Resistor (provided) terminates the two-wire-systems where the individual address of each module end of the Style B or D (class B or A) circuit (maximum IDC is selected using rotary switches. It provides a two-wire initiat- loop resistance is 25 Ohms). Install ELR across terminals 8 ing device circuit for normally-open-contact fire alarm devices. and 9 for Style D application. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module MMF-301(A) APPLICATIONS addresses on an SLC loop. It responds to regular polls from Use to monitor a single device or a zone of four-wire smoke the control panel and reports its type and the status (open/nor- detectors, manual fire alarm pull stations, waterflow devices, or maVshort) of its Initiating Device Circuit (IDC). A flashing LED other normally-open dry-contact devices. May also be used to indicates that the module is in communication with the control monitor normally-open supervisory devices with special super- panel. The LED latches steady on alarm (subject to current visory indication at the control panel. Monitored circuit/device limitations on the loop). is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the cir- MMF-302(A) SPECIFICATIONS cuit. Nominal operating voltage: 15 to 32 VDC. MMF-301(A) OPERATION Maximum current draw: 5.1 mA (LED on). Each MMF-301 (A) uses one of the available module Maximum IDC wiring resistance: 25 Ohms. addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- Average operating current: 300 pA, 1 communication and 1 m'aVshort) of its Initiating Device Circuit (IDC). LED flash every 5 seconds, 3.9k ed. EOL resistance: 3.9K Ohms. MMF-301(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): Nominal operating voltage: 15 to 32 VDC. DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms Average operating current: 350 pA, 1 communication every maximum. Current: 90 mA per module maximum. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Temperature range: 32°F to 120°F (0°C to 49°C). Shorted). Humidity range: 10% to 93% noncondensing. Maximum IDC wiring resistance: 1500 Ohms. Dimensions: 4.5' (11.43 cm) high x 4' (10.16 cm) wide x Maximum IDC Voltage: 11 Volts. 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x Maximum IDC Current: 400 pA. 2.125' (5.398 cm) deep box. EOL resistance: 47K Ohms. MDF-300(A) Dual Monitor Module Temperature range: 32°F to 120°F (0°C to 49°C). The MDF-300(A) Dual Monitor Module is intended for use in Humidity range: 10% to 93% noncondensing. intelligent, two-wire systems. It provides two independent two- Dimensions: 1.3 (3.302 cm) high x 2.75' (6.985 cm) wide x wire initiating device circuits (lDCs) at two separate, consecutive 0.65' (1.651 cm) deep. addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- Wire length: 6' (15.24 cm) minimum, controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- MMF-302(A) Interface Module cults ONLY Style D (Class A) IDC circuits are NOT supported in Supports compatible two-wire smoke detectors. any application. Page 2o14—DF-52121:D.01/20/2015 MDF 300(A) SPECIFICATIONS NOTE See installation instructions and refer to the SW Wiring Normal operating voltage range 15 to 32 VDC Manual PN51309 Maximum current draw: 6.4 mA (LED on).. Architects/Engineers' Specifications Average operating current: 750 pA (LED flashing). Specifications of these devices and all FireLite products are Maximum IDC wiring resistance: 1,500 Ohms. available from FireLite. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high .x 4" (10.16 cm) wide x 2125 (5.398 cm) deep MDF-300(A) AUTOMATIC ADDRESSING . . The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". . NOTE: "Ones" addresses on the MDF-300(A) are 0, 2; 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. . CAUTION: . Avoid duplicating addresses on the system. . . . Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4' (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- .4 lations. These modules are intended for power-limited wiring only. p The MMF-301 (A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM Approved CSFM: 7300-0075:0185 MEA:72-01-E Product Line Information NOTE: "A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. DF-52121 :D • 01/20/2015 - Page 3 of 4 Fire-Lite® is a registered trademark and LiteSpeed and FireWatch are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I 0 9001 We try to keep our product information up-to-date and accurate. . We cannot cover all specific applications or anticipate all requirements. MINERINI & MANIKUMMS All specifications are subject to change without notice. QUUITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 40f 4— DF-52121:13•01/20/2015 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email vladimir.kireyev@Honeywell.com. DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF7300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance With listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING Listee s name model designation electrical rating and UL label APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D4120 Duct Smoke Detector The InnovairFlexm. Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between !nnovaillJ3x Features 4-Wire Photoelectric, integrated low-flow technology • Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 m/s to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 3,4-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-fan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24 VAC/DC or 120 VAC Backward compatibility with existing Innovair products, including remote accessories Agency Listings LISTED APPROVED S611. 3033744 3242.16530207 The InnovairFiex D4120 47wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The lnnovairFlex housing provides ample wiring space, a 3A-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the 04120 may be used to monitor a second sensor, D4S, bmultaneously (i.e., supply and return side). As many as 50 InnovairFIex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The InnovairFIex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. WARNING: Duct smoke detectors are NOT a substitute for open area smoke detectors; NOT a substitute for early warning detection; NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information. InnovairFlexTM Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor InnovairFlex'° D4120 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke 'detector fits multiple footprints from square to rectangular. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the RTS2-AOS Multi-Signaling Accessory or the RTS151 KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. . . Size: (Rectangular Dimensions) (Square Dimensions) 14.38 in (37 cm) Length; 5 in (12.74. cm) Width; 2.5 in (6.36 cm) Depth . '7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth . .. Weight: . . 2.5 lbs (1.14 kg)' . . . . . . . . . . . . OperatingTemperature Range: : D412b & D4S: -4° to.158°F(-20° to 70°C); b4P120:'-40° to 158°F(7400 to 70°C) . . . . Storage Temperature Range: D4120 & D4S: -22° to 158°F (-30° to 70°C); D4P.120: -40° to 158°F (-40° to 70°C) Operating Humidity Range . 0% to 95% relative humidity non-condensing Air Duct Velocity: . 100 to 4000 ft/min (0.5 to 20.32 m/secl .. . . . .. Ii;tliij) Power supply, voltage: . 20-29 VDC . 24 VAC 50-60 Hz 1 zO VAC 50-60 Hz Input capacitance: . ' ' . 270 pF Max. 270 jf max. . N/A' ' ' . '• '. Reset voltage: . 3.0 VDC mm. . 2.0 VAC min.. 10 VAC min.. . Reset time: (with RTS151) , .03 to 0.3 sec. .03 to 0.3 sec. . .08 to 0.3 sec. ...... Reset time: (by power down) 0.6 sec. max.. 0.6 sec. max. . , 0.6 sec. max Power up time: 35 sec. max. . 35 sec. max. . 35 sec. max. Alarm response time: 15 sec. 15 sec. . 15 sec. Sensitivity Test: . See detector label See detector label See detector label Current Requirements: (Using No Accessories) Max. standby current: ' 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC60Hz Max. alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz Alarm Initiation contacts: (SPST) 2.OA @ 30 VDC (resistive) Alarm auxiliary contacts: 10A @30 VDC (resistive); 10A @250 VAC (resistive); ½ HP @240 VAC ; 1/4 HP © 120 VAC (DPDT) Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory contacts: (SPDT) 2.OA @30 VDC (resistive); 2.OA © 125 VAC (resistive) Device Standby Trouble Alarm APA151 12.5 mA n/a 30 mA Max. MHR/MHW 0 mA n/a 29 mA Max. RA100Z 0 mA n/a 12 mA Max. RTS151/RTS151KEY 0mN12mA n/a 12 mA Max. RTS2/lRTS2-AOS 3.0mA max 16 mA Max. with strobe: 55 mA max; without strobe 30 mA max Note: Any combination of accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the InnovairFIex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). ___..... W F- ------------ I POWER INPUTS (NOTE 1) I 4VACIDQ 1-.120-1 I I& & &I 910 I I OR I I AUXILIARY CONTACTS I I FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB SUPERVISORY CONTACTS I (NOTE 3) SUP N.O. .- SUP UUFMUSTED. CONTROL PANEL PANEL I I FIRST DETECTOR IN THE LOOP ------------ I POWER INPUTS (NOTE 1) I r4V _'.1 910 I OR I I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB 16 6 17: "81187 "JN I SUPERVISORY CONTACTS I (NOTE 3) I SUP N.O. SUP C LAST DETECTOR IN THE LOOP EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER 1 LL NOTE 1: 24V Power Inputs accept a non-polarized 24VDC or 24VAC NOTE 3: Supervisory contacts shown in standby position. Open 50-601-1z. 120VAC Power Inputs accept only 120VAC contacts indicate a trouble condition to the panel. See 50-60Hz. Connect power source to appropriate terminals specifications for contact ratings. of each detector. See specifications for additional power NOTE 4: Alarm Initiation contacts Shown in Standby position. Closed supply information, contacts indicate an alarm condition to the panel. See NOTE 2: Auxiliary contacts shown in standby position. Contacts specifications for contact ratings. switch during alarm as indicated by arrows. Auxiliary contacts are not to be used for connection to the control panel. See specifications for contact ratings. *Please refer to the corresponding installation manual for accessory wiring diagrams. Important Notes on 2:1 Sensor-to-Power Capability 2:1 sensor-to-power capability is not available for all InnovairFIex models. The feature is only available on the D4120 4-wire conventional models. .2:1 sensor-to-power capability can be enabled using one D4120 and one 045, or two D4S and one D4P120. Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered using the same independent supply. Polarity must be maintained throughout the interconnect wiring. Connect the INT+ terminal on unit 1 t the INT+ terminal on unit 2 and so on. Similarly, connect the INT/AUX- terminal on unit 1 t the INT/AUX- terminal on unit 2 and so on. Up to 50 04120 units, 50 D4P120 units, or 50 units of combination may be interconnected. Up to 10 DH100ACDC units may be interconnected. Please note that each of the 9 DH100ACDC units interconnected may be replaced by three D4P120 units. Therefore, when using the interconnect feature a single OH100ACDC can drive either 9 DHi00ACDCs or 27 04120 units. - - * NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. 1 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. LLIi Lfti RTS151 UL S4011 RTS151 KEYUL S2522 APA151 ULS4011 : •RTS2-AOS UL S2522 RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AOS a Ordering Information - - I D4120 4-wire photoelectric low-flow duct smoke detector Accessories D4S 4-wire photoelectric sensor component only ETX Metal exhaust tube duct width ift (0.3m) D41"120 4-wire photoelectric power board component M02-04-00 Test magnet only, 24 VAC/DC, 120 VAC 2051 4-wire conventional photoelectric sensor head MHR Mini Horn, Red OSI1 Metal sampling tube duct width up to ift (0.3m) MHW Mini Horn, White DST1 .5 Metal sampling tube duct widths 1 it to 2 ft P48-21-00 End cap for metal sampling tubes (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft RA100Z Remote annunciator alarm LED (0.6 to1.2m) DST5 Metal sampling tube duct widths 4 it to 8 it RTS151 Remote test station (1.2 to 2.4 m) DST10 Metal sampling tube duct widths 8 ft to 12 it RTS1 51 KEY Remote test station with key lock (2.4 to 3.7m) APA151 Remote annunciator with piezo alarm RTS2 - AOS Multi-signaling accessory with add on strobe SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 @2013SysternSensw Phone: 800-SENSOR2 • Fax 630-377-6495 Productopecs subject to change thoolnolce.5otoystenensor.com fix correniprodoci inforrna/on. including the OrIent version of this data sheet. www.systemsensor.com I HVDS00502. 10/13 LISTING No. 3242-1653:0207 Page 1 of I CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/0 BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact Vladimir Kireyev (203) 48476277 Fax (203) 484J309 Email Vladimir. Kireye~v@honeywell.com Models D4120 D4240 RD4120 P2703000PL TD41203 TD41204 LD4S LD412OX LD4120H, D45, D4P120, CD413120 LD4P120X, LD4PI20H, TD4C, PD4120, YD4120, YD4PI20, and AD4PI20four-wire conventional photoelectric duct smoke detectors and subassemblies. Unit consists of a duct detector housing. powerboard with electrical components and relays exhaust tubes and listed 2D51 detector head (CSFM Listing No 7272-1653:203). Model AD4S sensor component. Models *TD4C, LD4I2OX, LD4120H, LD4P120X and LD4P120H do not contain a 120 VAC transformer. Refer to listee's data sheet for additional detailed product description and operational considerations 20 29 VDC *24 VAC 120 VAC (except Models *TD4C LD412OX LD4120H LD4P120X and LD4P120H *do not have 120 VAC rating). In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, air velocity and UL label. Listed as conventional photoelectric duct smoke detector for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. DESIGN RATING: INSTALLATION MARKING: APPROVAL: *Rev. 03-27-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM - SENSORS 1 J SMOKE • -- Duct Smoke . . :. • • . Detector Accessories J . • Expand the versatility of the InnovairFIef line of duct •• 2 •• • . smoke detectors with System Sensor notification and test . L . . accessories • Available Accessories . Duct smoke detector accessories add functionality to the duct APA151 Piezo Annunciator smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All MHR Mini-Horn, Red System Sensor duct smoke detectors and accessories are UL listed. MHW Mini-Horn, White The APAI5I piezo annunciator, which replaces the APA451 with a RA100Z/RA100ZA Remote Annunciator new, improved look, provides an audible alarm signal, a red LED to RTS151 Remote Test Station indicate alarm status, and a green LED to indicate power status. It is RTSI51KEY Remote Test Station with Key intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with RTS2 Multi-Signaling Accessory NFPA 90A. p ADS Add-On Strobe The MHR and MHW SpectrAlert® Advance mini-horns feature RTS2-AOS Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications w3iere a small device is desired. The RAIOOZ and RAIOOZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTS151 and RTS151 KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFIex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used Agency Listings to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The ADS C E (Add-On Strobe) AOS model. is an optional accessory included with the RTS2- L TED 7303-1653:0212 iS APPROVED 7303-1653:0211 . - $ 02522 3034401 7135-1653:0196 9080301 . . SMOKE ATS2-AOS UL S2522 Specifications, Duct Smoke Detector Accessories I 1 ft1 .T!) Voltage Alarm LED: 2.8 to 32 VDC, 12 mA max. Regulated 24 VDC Power Requirements Operating Voltage 16 to 33 VDC Total Current: 105 mA max. Maximum Alarm Current 30 mA Test Switch 10 VA @32 VDC Temperature Range 0°C to 49°C (32°F to 120°F) Reset Switch 10 VA @32 VDC Relative Humidity 10 to 93% non-condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60°C (14°F to 140°F) Dimensions 4.6H x 2.9W .45D Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR (Full Wave Dimensions 4.8H x 2.90Wx 1.4'D Rectified) or Regulated 24 VDC or FWR 1 Sounder Current Draw 22 mA RIMS max. at 8 to 17.5 Volts DC Power Requirements Power LED (Green): 14 to 35 VDC, 29 mA RIMS max. at 16 to 33 Volts DC 12 mA max. Temperature Range 0 C to 49 C (32 F to 120 F) Alarm LED (Red) 2.8 to 32 VDC, Humidity Range 10 to 93% non-condensing 12 mA max. Total Current: 105 mA max. Nominal Sounder 3 kHz : Frequency Alarm Response Time 40 seconds max. Wire Gauge • 12 to 18 AWG Temperature Range —10°C to 60°C (14°F to 140°F) Dimensions 4.6H x 2.9W x 0.45D • • Relative Humidity 95% non-condensing • Wire Gauge • • l4to18AWG • • • Voltage Range • g g Conventional System: 3.1 to 32 VDC Dimensions 4.6H x 2.75"W x 1.8D • lntelligent System- 18to32VDC Maximum Alarm Current 10 mA Voltage 2010 29 VDC Dimensions 4.6 H x 2.8W x 1.3D Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 141022 AWG Dimensions 4.8W x 5.3H x 1.6D For the very latest product specifications and listing information, elf please visit the System Sensor Web site at w.systemsensor.com. -7 RTS151 UL S4011 RTS151 KEY UL S2522 APAI51 UL S4011 -7- AIDS r SYSTEM SENSOR° 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com 02013 Sytern Sensor. Product specifications subject to change without notice. Vint systenroensorcom for current product informabdn, including the latest version 01 this data sheet. HV0S20202..5/13 LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE System Sensor Unincorporated Div of Honeywell Intl Inc 3825 Ohio Ave St Charles IL 60174 Contact Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email Vladimir. Kireyev@honeyvVell.com DESIGN: Models RTS15I; RTS151 KEY and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION In accordance with listee's printed installation instructions applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. : MARKING: Listèe's name, model number, electrical rating, and UL label. APPROVAL Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CAS.TILLO, Program Coordinator Fire Engineering Division 22 AWG Solid Bare Copper, Insulation Thickness: .006" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches 4304 2 .014 0.120 APPLICATIONS: Fire Alarm, Signal Monitor/Detection Audio or Control Circuits CHARACTERISTICS: Operating Temperature: -10°Cto+800C Voltage Rating: 300 Volts Color Description: Chart F, Page 42. Jacket Color: Red Product Description: Solid bare copper Insulation: Semi-Rigid PVC Nylon rip cord for ease of jacket stripping Jacket: Flame Retardant PVC Specifications: UL 1pe FPLRJCMRJCL3R C(UL) CMG (14 and 12 AWG FPLR/CL3R only) Passes UL 1666 Riser Flame Test RoHS Compliant 18 AWG Solid Bare Copper, Insulation Thickness: .009" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches 4184 2 .014 0.144 4186 4 014 0 168 4188 6 .014 0.202 4190 8 014 0.120 4192 10 .014 0.260 16 AWG Solid Bare Copper, Insulation Thickness:.009" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches 4234 2 .014 .166 4236 4 014 194 14 AWG Solid Bare Copper, Insulation Thickness: .013" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches 4240 2 .014 .208 4241 4 014 245 12 AWG Solid Bare Copper, Insulation Thickness: .011" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches 4511 2 .014 .242 C US LISTED www.comtrancorp.com .1 ft CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1295:0100 Page 1 of 1 CATEGORY: 7161 —CABLES-FIRE PROTECTIVE SIGNALING LISTEE: Comtran Cable; LLC.330A Turner Street, South Attleboro, MA 02703-7714 Contact: Bruce Lamoureux (508) 399-7004 Ext: 245 Fax (508) 399-7360 Email: Bruce.Lamoureux@comtrancorp.com DESIGN: Types FPL, FPLR and FPLP. Refer to listee's data sheet for detailed produát description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes, NEC Article 760 and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, NEC rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. 6-16-10 MA TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division