Loading...
HomeMy WebLinkAbout7625 VIA CAMPANILE; 122; FPC2018-0078; PermitCcity of Carlsbad AG PGHM Print Date: 10/05/2022 Permit No: FPC2018-0078 Job Address: 7625 VIA CAMPANILE, 4* 122, CARlSBAD, CA 92009-8489 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2230531200 Track #: Applied: 03/07/2018 Valuation: $73,716.08 Lot #: Issued: 03/22/2018 Occupancy Group: Project 4*: Finaled Close Out: 04/15/2021 #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Fieri, Dominic Plan Check 4*: Project Title: Description: JERSEY MIKES -SPRINKLER TI /ADD 14 NEW HEADS (SHELL TO RESTAURANT TI) Applicant: FPContractor: Ci SUPPRESSION INC CJ SUPPRESSION INC JORDAN LUNDBERG 205 LEWIS CT 205 LEWIS CT CORONA, CA 92882-1812 CORONA, CA 92882-1812 (951) 735-5560 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 2 SCHEDULE 10 SPECIFICATIONS . NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in. mm in. mm in. mm lbs/ft. kg/rn CRR Lift 11/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1% 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 2¼ 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3.500 88.9 3260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5,62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.367 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 2526 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRP is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in. mm in. mm in. mm Ibs./ft. kg/rn CRR Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1¼ 1.660 42.2 1.380 351 .140 3.56 2.27 3.39 1.00 51 1% 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 32.5 .154 3.91 3.66 5.45 • 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). C@ ~P >D A PROVE FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6' receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: . CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK HOT-DIP GALVANIZED LI L iL1 r ET P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 302 STAINLESS STEEL RING HANGER SIZE - 1/2 thru 8 inch pipe. MATERIAL - Stainless Steel - (Type 304) CONFORMS WITH: Federal Specification WW-H- 171 (Type 10, Manufacturers Standardization Society ANSI/MS S-SP-5 8 (Type 10). MAXIMUM TEMPERATURE - 6500F. FUNCTION - Pipe hanger component for use on steel or copper piping. For use with CPVC - consult factory. INSTALLATION - Per NFPA 13,13R and 13D. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Stainless steel swivel nut. * Custom fit swivel nut for better retention in ring body. ORDERING - Part #, pipe size. IMPERIAL MAX REC. LOAD LBS. METRIC PIPE ROD PIPE ROD 112 3/8 400 10 314 3/8 400 20 10 1 3/8 400 s 10 3/8 400 32 1 10 1 112 3/8 400 _ 40 10 2 3/8 400 50 10 21/2 3/8 600 65 io 3 3/8 600 80 10 31/2 3/8 600 10 4 3/8 1000 100 10 5 1250 125 12 6 112 1250 150 12 8 1250 200 2 Order Part #300m Note 1/2'.' Ring Hanger not<FM> approved 1/08 C®US LISTED Fig. 78 - All Steel Ceiling Plate Size Range - 3/8 rod Material - Carbon Steel Features - Attachment to wood beams, ceilings, metal decks or. walls. Can also be welded to steel beams. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Additionally, (UL) has listed the Fig. 78 with fasteners as shown in the table below. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Patent #5,702,077 UL Listed Fastener Table Pipe Size Qty Fastener Type Material 1/2-2 21/2 -4 1/2 -2 2 2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw 1/4 x 11/2 wood screws* 1/4 x 1 tek screws Wood Wood Metal (18 gauge) 1/2 -2 1/2 -2 2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw #14 x 2 A-point- hex-was her- head sheet metal screw Wood Wood thru 5/8 gyp board * No pre-drilling Dimensions .Weights Pipe Size A Max. Rec. Approx. B C D E Load Lbs.* Will 00 1/2-2 5 - 6 3 21/a 11/8 5/16 3/8 Consult factory for data 150 15 * Minimum safety factor of 5 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwtolco.com Fig. 58 -Threaded Side Beam Bracket Size Range - 3/8 rod, pipe sizes 1/2 thru 4 Material - Carbon Steel Function - Practical and economical bracket used to support piping from wood, concrete or steel beams. Features - Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept 3/8 and 1/2 fastener bolts. Per NFPA 13: 1/2 thru 2 pipe requires 3/8 fastener, 21/2 thru 4 pipe requires 1/2 fastener.* Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4 pipe. *Note - Additionally UL has listed the Fig. 58 with fasteners as shown in table below. Finish - Plain Note - Available in Electro-Galvanized finish. Order By - Figure number and finish C® US LISTED UL Listed Fastener Table 2.1 ' (No Pre- Pipe Size Qty. Fastener Type Material to 4 in lipe 2 2 #16 x 2 Drive Screws Wood PerNFPA 2 21/2 -4 1 1 3/8 Lag Bolt 1/2 Lag Bolt Wood Wood . To4 inch Pipe - - 3½ 2 1/4 x 11/2 Lag Bolt Wood 4 2 1/4 x 2 Lag Bolts* Wood Drive r S 4 2 1/4 x 1 tek screws 14 gauge 112 Thru 2 IflC Pipe - 4 2 1/4 x 1 tek screws 16 gauge :-. - * No pre-drilling required \ i - Dimensions • Weights ', •*y_i - - Pipe Rod Max. Rec. Approx. -. Size Size A B C Load Lbs.* Wt./100 ) 1/2 thru 4 3/8 2/4 1112 11/8 300 14 - With safety factor of 5. Into Wr lKa. s -i - - Up To 4 \--_.- OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folcO.com SAMMYS® FOR WOOD SAMMYV FOR WOOD - Vertical A, I Application Not less than Wood Flooring 2' noninal width Not le. than (depth or s de No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Double Shee Ceiling II Reduces installation costs Made in the U.S.A. Watch a video demonstration at .7., www.itwbuildex.com i - #14 Black Nut Driver Part # 8113910 i . #14 SW Red Nut Driver Part #8114910 4ltLfTi111fl .- 1/4' 8002957 GST 100 1/4x1 210 (7/16OSB) 25 125 1/4 8003957 GST 200 114 x 2 1760 (Fr) 25 125 1/4' 8004957 GST 300 1/4 x 3 2060 (Fir) 25 125 3/8 8087957 GST 10 1/4 xl 300 25 125 670 -' 3/8' 8008957 GST 20 1/4 x 2'.1760 (Fir) 850 1475 25 125 [ 3/8 8068925 GST 20 SS 1/4 x 2' - 1760 (Fir) 850 - 25 125 3/8' 8009925 GST 25380 38 x 2-1/2 2113 (Fir) 1500 25 125 r 3/8' 8010957 GOT 30 1/4 x 3 2060 (Fir) 1500 1475 - 25 • 125 3'8' 8069925 GST 30-SS 114 x 3 2060 (Fir) 25 125 3/6 8011925 GST 40 1/4x4' 2180 (Fir) - 25 125 12' 8013925 GOT 2 114 x 2 1760 )Fir) 25 125 1/2 8014925 GOT 2.5-380 3/8 x2-1J2 2113 (Fir) . 25 125 1/2 8015925 GST 3 1/4 x 3 2275 (Fir) 25 125 \ 2O ,. Du ow '577 9 MADE IN U.S.A 'Ni ors - SPECIAL NUT DRIVER SYSTEM: The nut drivers we -adesigned with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continLe drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. I _ ® ZS uc J ILPCBI chanicaI io ia tC Outlets SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. STYLES 920 AND 920N STYLE 920 CROSS PATENTED MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade 'E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By _________________________ Spec Sect Pa ra Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV K \4taulic 11.02 1 GROOVED OUTLET CAF STYLES 920 AND 920N DIMENSIONS 01.1 V1110-A IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. 2 ½(a) X 920N 500 3450 1.50 38.1 51 64 - 2.00 136 70 1.5 - (a )a) 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 00N 3450 38.1150:64: 41 136 701.5 - 10(0 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 OON 2 38 47 64 - 41 136 70 14 - 500 175205 2.75 3.00 1.61 5.35 3.00 3.5 i 3.2 32 - 3450 44.5 52 70), 76 1 13676 500 I 175 03 275 312 161 535 325 36 32 ZO 920N 3450 445 70 79 ' 136 83 17 15 2½ 00(00 920N 500 1.50 2.2' 2.74 937 564 2.75 3.0 65 1a. 3450 381 55 70 - 46 143 70 14 )a(0.. 500 150 218 274 182 7,64 275 30 20 920N 3450 38.1 55 70 : : 46 143 70 14 920N 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 3450 38.1 52 70 ) - 46 143 70 1.4 - 1 / cal a 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 920N 3450 445 58 76 53 4 46160 76 17 15 1½ 3(a) 920N 500 2,00 2.28 3.00 3.25 1.82 ). 6.26 3.25 3.6 3.3 417 3450 50.8 55 79 83 46115583 1.7 1.6 ½ (a) 920N 300 1.50 1 2.22 275 2.25 6.46 3.18 3.9 761 x 2065 381 56 70 - 57 16 81 1.8 - 31, (al 300 1.50 219 275 275 66 3.18 3.9 20 920N 2065 381 56 70 - 4 81 18 - 1 (a 300 150 207 275 - 225 (D 46 3 38 - 25 j 1 20651.38.1153 70 57 164 8, 1.7 1½(ai 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 1 a 20N 3450 445 58 76 84 49 160 76 16 15 1 )a1 500 2.00. 2.28 3.00 3.31 1.92 a 70 3.25 3.5 3.3 a, 920N 3450 508 58 76 84 AO 10 83 1.6 15 7 0(a)" 500 1.50 2.52 3.05 - 225 615 275 . 3.4 - 80 '5 3450 38.1 64 78 58 156 70 1.6 0 (a)" 500 1.50 2.49 3.05 2.28 617 7.75 3.4 20 0"ON ' 3450 38.1 63 78 - 58 156 70 '.6 '(a) 500 1.50 2.38 3.06 - 2.28(6:5 2.75 3 21 25 9709 3450 38.1 61 78 i 58 156 70 1.6 10 (01 to 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3,7 37 (61 9"ON '- 3450 44.5 65 83 90 58 156 76 : 1.8 1.8 500 200 0 356 228 15 325 41 38 45 6 3 ON 3450 5 508 I 8" 90 58 156 83 19 : 18 2 (a( " 500 2.50 273 7.50 : 3.56 2.28 6.75 3.88 4.9 4.6 50 920N 3450635 70 89 901.58 I 244 172 672 99 388 2.3 1 22 38 500 250 300 90 'a 50 920N 3450 635 76 - 95 62 171 99 - 1 1.8 TABLE CONTINUED ON PG. 3 "i Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 1- Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ictauhc' 11.02 2 GROOVED OUTLET r SEE "No I 'F Aw is 0I-_Z CARBON STEEL PIPE HOLE CUT PRODUCTS hanic Pf STYLES 920 AND 920N DIMENSIONS TABLE CONTINUED FROM PAGE 2 4 ½ (a) 11 920N 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 100 15 3450 38.1 - 77 90 68 178 70 1.8 3/4 (a) 0 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 - 76 90 68 178 70 1.8 1(a) 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 920N 3450 38.1 73 90 - 68 178 70 1,8 11/4 (a) il 500 1.75 3.08 i 3.78 4.00 2.69 7.01 3.00 1 4.0 3.6 32(b) 20N 3450 44.5 78 1 96 102 68 178 76 1.9 1 1.8 1½ (a) tv 20N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 . 83 2.0 1.9 2 (a) to 500 2.50 3.25 1 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 21/2 (a) t 920N3450 500 63.5 2.75 83 102 102 68 2.88 4.00 4.00 -2.69 178 7.34 99 4.63 2.3 5.8 2.1 5.0 920 186 118 2.6 2.3 65 3450 69.9 73 102 102 68 761 mm 920 500 3450 2.75 69.9 2.88 4.00 2.69 73 - 102 68 7.34 186 4.63 118 - 6.4 2.9 3(a) t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 8n 920 3450 RRQ 84 114 108 68 196 130 3.8 2.9 FEMALE THREADED OUTLET 1080 x 920N 500 1.75 3.08 3.78 23 7.64 3.05 5.0 -. 32 3450 44.5 1 78 i 96 67 194 78 2.3 - 1 ½ (a)a 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 Provides a direct branch connection at - 40 920N 3450 .50.8 .. 102 - 67 .3 194 .83 2.3 any location where a hole can be cut 2(a) 920N 500 2.50 3.25 4.00 - 2.63 7.64 4.00 4.0 in the pipe : 83 102 67 19 102 L9 3450 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 A pressure responsive gasket provides 76m 92 .3450 ........73 .102 102 .67 ...94 ..109 ..~6 the seal 3(a) - 1i1i 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 80 350 88.9 84 114 114 67 194 124 3.1 Request Publication 11.03 for 5 11/2 (a) t 920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 Mechanical-T cross assemblies 125 X4 345050.8 102121 121 80 24694 3A - 2(a) t 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 Pressure rated up to 500 psi/3450kPa 50 3450 615 102 121 121 80 1 246 111 37 on steel pipe; also available for use 2½ (a) 920 500 2.75 3.63 4.75 1 4.75 3.16 9.70 4.63 8.3 with HDPE pipe 65 3450 69.9 92 121 121 80 ............ 500 2.75 3.75 4.75 3.16 9.70 4.63 Sizes from 2 x ½/50 x 15 mm - ±m 920 - 699 95 121 80 246 118 through 8 x 4/200 x 100mm 3(a) t 920 500 - 3.50 3.81 5.00 363 3.16 9.70 5.31 8.4 80 3450 88.9 97 127 118 30 246 135 3.8 ---.--1-.,-,-- -... .... 2 920N 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 133.0 x5oj 3450 635 95 114 203 99 36 920 500 3.50 3.81 1 5.00 3.00 9.46 5.31 8.0 80 3450 i 88.9 97 127 - 76 240 135 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2010 vICTAULIC COMPANY. ALL RIGHTS RESERVED. RF'J K \ %taukc CARBON STEEL PIPE HOLE CUT PRODUCTS M.echanicalkl __EI STYLES 920 AND 920N CL: .S DIMENSIONS INone No' VA GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). -t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com \/taulIc VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 vIcTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02 4 PEV K GROOVED OUTLET FEMALE THREADED OUTLET CARBON STEEL PIPE HOLE CUT PRC ICTS hanicaIT® r- -10 01: STYLES 920 AND 920N DIMENSIONS Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com vIcTAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 ViCTAULIC COMPANY. ALL RIGHTS RESERVED. x/ctaulie RFV K CARBON STEEL PIPE HOLE CUT PRODUCTS TIni STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalT® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for Values: = Where: - = Q2 Where: Q = Flow (GPM) K Q = Plow (M3 /h) = Pressure Drop (psi) AP = Pressure Drop (bar) Q = C x C, Flow Coefficient Q = K x K = Flow Coefficient Exaggerated for clarity Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 111)2 6 CARSON STEEL PIPE HOLE CUT PRODUCTS MechancaT® Cvii i STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 87100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cuffing tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap Il is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 57125 mm, 67150 mm and 8'7200 mm diameter pipe. The Style 931 comes with a 2½'/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCT) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2010 ViCTAULiC COMPANY. ALL RIGHTS RESERVED. I2FU K x04-c—tauhlor I 'T STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV K UPDATED 4/2010 ctauIc VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. .1U12 K SAMMYS® FOR WOOD I! No pre-drilling required. Quick to install using the Sammy Nut Driver with an 1 8 cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. Watch a tdeo domonstrafion at . www.itwbuildex.com 1/4' 8002957 GST 100 1/4 x 1' 25 125 1/4' 8003957 GST 200 1/4x2' 1760 (Fir) 25 125_,- 114" 8004957 GST 300 - 1/4 x 3' 2060 (Fir) 25 125 - 3/8' 8007957 GOT 10 1/4x 1' 670 300 25 125 3/8 8008957 GST 20 1/4 x 2' 1760 (Fir) - 850 - 1475 25 125 I - 3/8' 8068925 -- GST 20-SS 1/4 x 2' 1760 (Fir) 850 25 12 /1. 3/8 8009925 GST 25-380 3/8 x 2-1/2' 2113 (Fir) 1500 25 125 #14 Black . 3/8" 8010957 GST 30 1/4 x 3' 2060 (Fir) 1500 1475 25 125 Nut Driver 38 8069925 GST 30 OS 1/4 x 3" 2060 (Fir) 25 125 Part# 8113910 : 3/8 8011925 GST 40 1/4x4" 2180 (Fir) 25 125 1/2' 8013925 GST 2 1/4 x 2' 1760 (Fir) 25 125 1/2' 8014925 GST 25-380 3/8 x 21/2' 2113 (Fir) - 25 125 112" 8015925 GST3 1/4x3' 2275 (Fir) 25 125 #14 SW Red Nut Driver Part #8114910 is MADE IN U.s.A SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, contirue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. I Worldwide tqto www.tyco-fire.com Contacts Series TY-B, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers described in this data sheet are standard response, standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-B Sprinklers are described in Technical Data Sheet TFP352. Sprinkler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TV-B Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Numbers (SINs) TY315 ......Upright 5.6K, 1/2"NPT Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K = 5.6 GPM/ps1112 (80,6 LPM/bar112 Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C)t 11.JL, C-UL, and VdS Approved only JANUARY 2013 Finishes Sprinkler: Natural Brass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI52 TFPI52 Page' of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON * 6 -_ 5 7/16" (11,1mm) _ _ t\L ..i!itj" f _______ I NOMINAL ________ 2" I MAKE-IN (50,8 mm) 2" 1/80 i 1 3 (50,8 mm) _______ (34,9 mm) WF 1 A 1/2 NPT** DEFLECTOR* 2-7/8 (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT (TY315) AND PENDENT (TY325) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Loss Preven- tion Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI52 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate, as applicable, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 15 or Style 20 Closure over the Series TY-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Thereafter, annual inspections per NFPA 25 are required; however,' instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national eodës 2-7/8 DIA. (73,0 mm) - 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER FITTING FLUSH 3/8±5/16 I (9,5±7,9 mm) 5/8 (15,9 mm) I 1/8] '- MOUNTING SURFACE \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-B PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. ( \ &P, 5/16±1/4"1/2(12,7mm) 7,9±6,4 mm) FITTING (57,2 mm FLUSH MOUNTING SURFACE m) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TV-B PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI52 Page 4 of 4 PIN* 77 - XXX - X - XXX I SPRINKLER TEMPERATURE FINISH RATINGS SIN I I 1 NATURAL BRASS 570 5.6K UPRIGHT (1/2NPT) TY315 L.. SIGNAL WHITE (RAL 9003) 571 5.6K PENDENT (1/2 NPT) TY325 3 PURE WHITE (RAL 9010)** * Use suffix I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-570-4-175-I I Eastern Hemisphere sales only TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS - PART NUMBER SELECTION - Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (SIN), K=5.6, (Upright or Pendent) Sprinkler Standard Response, (specify) temperature rating, (specify) finish, P/N (Table A) Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) 360 360°F (182°C) GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. t1JCG /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series DS-1 - 56 K-factor Dry Type Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series DS-1, 5.6 K-factor, Quick Response, Standard Coverage, Dry Type Sprinklers are decorative 3 mm glass bulb automatic sprinklers de- signed for the following typical uses: where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing temperatures (e.g. sprinkler drops from unheated portions of buildings) where sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping exten- sions through a wall to protect an unheated area of a building) where sprinklers are used on sys- tems that are seasonably drained to avoid freezing (e.g. vacation re- sort areas) WARNINGS The Series DS-1 Dry Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS-1 Dry Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers TY3235 - (Pendent) TY3135 - (Upright) TY3335 - (Horizontal Sidewall) Technical Data Approvals UL and C-UL Listed. FM and NYC Approved. (Refer to Table A) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient K = 5.6 GPM/ps1112 (80,6 LPM/bar112) Temperature Ratings Refer to Table A Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated, Brass Plated Physical Characteristics Inlet......................Copper Plug .....................Copper Yoke ...............Stainless Steel Casing .....Galvanized Carbon Steel Insert ...................Bronze Bulb Seat ...........Stainless Steel Bulb.......................Glass Compression Screw.........Bronze Deflector .................Bronze Frame ....................Bronze Guide Tube ..........Stainless Steel Water Tube ..........Stainless Steel Spring ..............Stainless Steel Sealing Assembly................. Beryllium Nickel w/Teflon* Escutcheon ..........Carbon Steel *Registered Trademark of DuPont Patents U.S.A. Patent No. 5,188,185 Page 1 of 8 JANUARY, 2008 TFPSIO Page 2 of 8 TFP5IO SPRINKLER FINISH TY3235 Pendent TY3235 Pendent TY3335 Hor. Sidewall w/ Standard w/ Std. Escutcheon with top of Recessed Escutcheon (Ref. Fig. 5) Deflector-to-Ceiling (Ref. Fig. 3) w/ Deep Escutcheon distance of w/ Wide Flange (Ref. Fig. 6) 4 to 12 inches Recessed Escutcheon w/o Escutcheon (100 to 300 mm) (Ref. Fig. 4) (Ref. Fig. 7) w/ Std. Escutcheon (Ref. Fig. 9) w/ Deep Escutcheon TY3135 Upright (Ref. Fig. 10) w/o Escutcheon w/o Escutcheon (Ref. Fig. 8) (Ref. Fig. 11) Temperature Bulb Natural Chrome White Natural Chrome White Natural Chrome White Rating Color Code Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F/57°C Orange 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*, 2*, 3** 4 1*, 2*, 4 155°F/68°C Red 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*,2*,3**,4 1*, 2',4 175°F/79°C Yellow 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1 1*,2*,3**,4 1*,2*,4 200°F/93°C Green 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*, 2*, 3** 4 1*, 2-,4 286°F/141°C Blue N/A 1,2, 3,4 1, 2,4 1*, 2-,3**, 4 1*, 2*, 4 Notes: Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). Listed by Underwriters Laboratories for use in Canada (Maximum order length of 48 inches). Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) Approved by the City of New York under MEA 352-01-E. * Light and Ordinary Hazard Occupancies Only. ** Light Hazard Occupancies Only. N/A - Not Available. TABLE A SERIES DS-1, QUICK RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET ' GASKETED SPRING PLATE SEAL - YOKE SPRING CASING WATER TUBE INSERT GUIDE TUBE BULB SEAT FRAME 3mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 QUICK RESPONSE DRY TYPE SPRINKLER ASSEMBLY I WRENCH RECESS WRENCH zcQ1 FLAT PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCH FLATS FIGURE 2 W-TYPE 7 SPRINKLER WRENCH TIP51O Page 3 of 8 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ,-___L--------- FACEOF SPRINKLER Ljj LU FITTING L r" I IL -it ORDER LENGTHS: 3-1/2 to 48" (88,9 to 1219,2 mm) IN 1/4 (6,4 mm) 2-1/4 DIA. INCREMENTS (57,2 mm) FACE OF CEILING m FIGURE 3 TY3235 PENDENT wi STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) f---L-------- FACE OF SPRINKLER L FITTING LMJ ORDER LENGTHS: 3-1/2" to 48" (88,9 to 1219,2 mm) IN 1/4" (6,4 mm) 3" DIA. INCREMENTS (76,2 mm) FACE OF CEILING mm) FIGURE 4 TY3235 PENDENT wi WIDE FLANGE RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TODESIGN CRITERIA SECTION) --,--------- FACEOF '--•lI 1' I if SPRINKLER L L J FITTING L. _ L _____ ORDER LENGTHS: 2-1/2" to 48" 1-3/4" DIA. (63,5 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) INCREMENTS j I c v I FACE OF CEILING 2-3/16" ± 1/8" 3" DIA. (55,6 :t 3,2 mm) (76,2 mm) FIGURE 5 TY3235 PENDENT wi STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) --- FACE OF Ift.. LU SPRINKLER -I m __ L FITTING ORDER LENGTHS: 3-1/2" DIA. 1/2" to 46" h(88,g mm) (12,7 to 1168,4 mm) 2-1/2 DIA INCREMENTS I FACE OF I IN 1/4' (6,4 mm) 5mm CEILING 4-1/4" ± 1/8' (108,0 ± 3,2 mm) FIGURE 6 TY3235 PENDENT wi DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ,---- FACE OF SPRINKLER Li FITTING L r LJ ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE 7 TY3235 PENDENT w/o ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5' to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 8 TY3235 UPRIGHT w/o ESCUTCHEON. ORDER LENGTHS: FACE OF 1/2"t045-3/4"(12,7t01162,1 mm) MOUNTING IN 1/4 (6,4 mm) INCREMENTS SURFACE 4-13/16.1 ± 1/8 P~~2112 (122,2±3,2mm) DIA. FACE OF (63,5 mm) SPRINKLER FITTING 3-1/2" DIA. SPRINKLER FITTING 3.5" IT (88,9mm) (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 10 TY3335 HORIZONAL SIDEWALL wi DEEP ESCUTCHEON Page 4 of 8 TF P5 10 ORDER LENGTHS: 2-1/2 to 48' (63,5 to 1219,2 mm) IN 1/4 (6,4 mm) INCREMENTS 4±1/8" (101,6 ± 3,2 mm) FACE OF FACE OF I 1-3/4" DIA. - SPRINKLER MOUNTING -] (44,5 mm) FITTING SURFACE 3" (76,2 mm) 3 SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16 CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3335 HORIZONAL SIDEWALL wi STANDARD ESCUTCHEON Operation When the Series DS-1 is in service, water is prevented from entering the assembly by the Plug & Belleville Seal- ing Assembly (Ref. Figure 1) in the Inlet of the Sprinkler. The glass Bulb contains a fluid that expands when exposed to heat. When the rated tem- perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to ex- pand and push the Water Tube as well as the Guide Tube outward. This ac- tion simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville Seal from the Inlet allowing the sprin- kler to activate and flow water. Design Criteria The Tyco Series DS-1 Sprinklers are intended for use in fire sprinkler sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The 1 inch NPT Series DS-1 Sprin- klers are to be installed in the 1 inch NPT outlet or run of malleable or duc- tile iron threaded tee fittings that meet the dimensional requirements of ANSI B16.3 (Class 150) or cast iron threaded tee fittings that meet the dimension- al requirements of ANSI B16.4 (Class 125). The Series DS-1 Sprinklers may also be installed in the 1 inch NPT out- let of a Grinnell Figure 730 Mechani- cal Tee; however, the use of the Figure 730 for this arrangement is limited to wet pipe systems. Typically, the end sprinkler fitting on a branch line is plugged as shown in Figures 3 through 11. The DS-1 Sprin- klers cannot be installed into an elbow fitting. For wet pipe systems, the sprinkler drop may be installed as shown in Fig- ure 12. The configuration in Figure 12 may only be used where the sprinkler fitting and water filled pipe above the sprinkler fitting is not subject to freez- ing and where the length of the DS-1 Sprinkler has the minimum exposure length per Figure 14. For wet pipe systems, the DS-1 Sprin- klers may also be installed in the fol- lowing Tyco® CPVC fittings: (P/N 80145) 1" x 1" NPT Female Adapter or (P/N 80249) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee. For dry pipe systems, only use the side outlet of maximum 2-1/2 inch size ORDER LENGTHS: 5-1/2" to 48' (139,7 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS FACE OF J- SPRINKLER FITTING MINIMUM 2-1/4" (57,2 mm) DEFLECTOR TO MOUNTING SURFACE 5/16" SPRINKLER FITTING (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 11 TY3335 HORIZONAL SIDEWALL w/o ESCUTCHEON TFP5IO Page 5 of 8 reducing tee's when locating the DS- 1 Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 13 to assure complete drainage of water from above the DS-1 Sprinklers and the branch line. NOTE Do not install the Series DS-1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or bind- ing of the inlet Plug; or, insufficient engagement of the inlet pipe threads with consequent leakage. Branch, cross, and feedmain piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protect- ing areas subject to freezing tempera- tures (e.g., sprinkler drops into freez- ers), consideration must be given to the appropriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduc- tion. When the temperature surround- ing the wet pipe sprinkler system is maintained at a minimum temperature of 40°F/40C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 40°F/40C - Ref. Figure 14): 12 inches (300 mm) when the tem- perature within the protected area is -20°F/-29°C 18 inches (450 mm) when the tem- perature within the protected area is -40°F/-40°C 24 inches (600 mm) when the tem- perature within the protected area is -60°F/-51°C For protected area temperatures between those given above, the mini- mum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. The 2007 edition of NFPA 13, Sec- tion 8.4.10.2 requires that dry sprin- klers connected to wet pipe sprinkler systems protecting insulated freezer structures have the clearance space around the sprinkler barrel be sealed. The use of the Model DSB-2 Dry Sprinkler Boot described in Technical Data Sheet TFP591, and illustrated in Figures 15 and 16, will meet the intent of NFPA 13. TO WET SIDE SYSTEM OUTLET PLUGGED H EATED AREA - 1INCH DSB-2 NPT TEE INTENDED (SEE DESIGN FOR FREEZER CRITERIA STRUCTURES SECTION) FIGURE 12, SPRINKLER FITTING IN HEATED AREA RUN OUTLET PLUGGED 1 INCH NPT TEE TO DRY TO DRY (SEE DESIGN I AREA I SECTION) I SUBJECT TO DSB-2 INTENDED FOR FREEZER FREEZING A STRUCTURES FIGURE 13, SPRINKLER FITTING IN UNHEATED AREA FACE OF SPRINKLER FITTING Ifl HEATED EXPOSURE AREA LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES FIGURE 14, EXPOSURE LENGTH STRAP TIES -) (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE 1-3/4 DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER 1-3/4 DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE DSB-2 BOOT STRAP TIES (ENDS ON DS-1 OPPOSING SHOWN WITH SIDES OF STANDARD BOOT) ESCUTCHEON FIGURE 16 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER Page 6 of 8 TFP5IO Installation The Series DS-1 Dry Type Sprinklers must be installed in accordance with the following instructions: NOTES The Series DS-1 must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F/57°C rating to 1/8 inch (3,2 mm) for the 286°F/1410C rating. A 1 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of torque may dis- tort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under-or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent posi- tion, and upright sprinklers must be in- stalled only in the upright position. The deflector of a pendent or upright sprin- kler is to be parallel to the ceiling. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpen- dicular to the back wall and parallel to the ceiling. The word "TOP" on the De- flector is to face towards the ceiling. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, use a W-Type 7 Sprinkler Wrench (Ref. Figure 2). The wrench recess of the W-Type 7 is to be applied to the sprinkler wrench flats (Ref. Figure 2). Step 4. After the ceiling/wall has been installed/finished, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Deep Escutcheon, hold the outer piece in contact with the mounting sur- face (ceiling), and then rotate the in- ner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The Tyco® Series DS-1 Dry Type Sprin- klers must be maintained and ser- viced in accordance with the following instructions: NOTES Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tems must be obtained from the prop- er authorities and all personnel who maybe affected by this action must be notified. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole is an indi- cation that there may be weepage past the Inlet seal and that the sprinkler needs to be removed for determining the cause of leakage (e.g. an improp- er installation or an ice plug). The fire protection system control valve must be closed and the system drained be- fore removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age -before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP510 Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Dry Sprinklers: Contact your local distributor for availability, and please specify the following: 1. Sprinkler. Model/SIN. Quick Response, Standard Cover- age, Dry Type Sprinkler Deflector Style. 5.6 K-factor. Order Length. Dry Type Sprinklers are furnished based upon Order Length as mea- sured per Figure 3 through 11, as applicable. After the measurement is taken, round it to the nearest 1/4 inch increment. Inlet Connection (1 Inch NPT or ISO 7-Ri). Temperature Rating. Sprinkler Finish. Escutcheon Style and Finish, as applicable. Part Number from Table B. (Part numbers are for 1 inch NPT stand- ard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description.) 2. W-Type 7 Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers. Model DSB-2: Specify: Model DSB-2 Dry Sprinkler Boot*, P/N 63-000-0-002. * Includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive (quantity of adhesive is sufficient for installing one Boot) I I ORDER LENGTH (1) (EXAMPLES) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" ESCUTCHEON FINISH (2) WHITE WHITE CHROME WHITE WHITE (RAL9010)" BRASS PLATED Page 8 of 8 TFP5IO P/N 60-XXX- X - XXX _____ SPRINKLER FINISH MODEL/SIN _ 1 NATURAL BRASS 4 WHITE POLYESTER 9 CHROME PLATED 0 CHROME PLATED 3 WHITE (RAL9010)* 2 1 NATURAL BRASS 36 Pendent wl Standard TY3235 Escutcheon (1" NPT) (Fig. 5) 33 Pendent WI Deep TY3235 Escutcheon (1" NPT) (Fig. 6) 37 Pendent wl Std. Recessed TY3235 Escutcheon (1" NPT) (Fig. 3) r32Pendent w/o Escutcheon TY3235 (1" NPT) (Fig. 7) 34 Sidewall wl Standard TY3335 Escutcheon (1" NPT) (Fig. 9) 43 Sidewall wl Deep TY3335 Escutcheon (1" NPT) (Fig. 10) 44 Sidewall w/o TY3335 Escutcheon (1" NPT) (Fig. 11) F I-_______ 38 Upright w/o Escutcheon I TY3135 - (1" NPT) (Fig. 8) TEMPERATURE RATING (3) 0 135°F157°C 1 155°F168°C 2 175°F179°C 3 200°F/93°C 4 286°F/141°C NOTES Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment, Escutcheon Finish applies to sprinklers provided with escutcheons. 28617/141C temperature rating applies to non-recessed sprinkler assemblies. * Eastern Hemisphere sales only. TABLE B PART NUMBER SELECTION SERIES DS-I, QUICK RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "I" for ISO 7-17I Connection, e.g., 1-60-361-1-180) © 2007-2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446