Loading...
HomeMy WebLinkAbout7630 VIA CAMPANILE; 136A; FPC2019-0258; PermitPER]ET REPORT _"(?'~'Cityv of I k- CRESIAN I - - Print Date: 10/05/2022 Permit No: FPC2019-0258 Job Address: 7630 VIA CAMPANILES # 136A, CARLSBAD, CA 92009-8486 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2230531200 Track #: Applied: 11/13/2019 Valuation: $38,138.20 Lot #: Issued: 12/12/2019 Occupancy Group: Project #: Finaled Close Out: 12/20/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Project Title: Description: PRETTY PLEASE -SPRINKLER TI (14 HEADS) Applicant: FPContractor: INNOVATIVE FIRE PROTECTION INC INNOVATIVE FIRE PROTECTION INC DAVIN BROOKS 8779 COTTONWOOD AVE. # STE 101 8779 COTTONWOOD AVE, # STE 101 SANTEE, CA 92071-4457 SANTEE, CA 92071-4457 (619) 593-8200 (619) 593-8200 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553:00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Bulletin 014 March 2019 Rellabl4a Model Fl FR Series Quick Response Glass Bulb Sprinklers Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSl/UL199. FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS SchadenverhUtung GmbH (VdS) Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1 425) 0786-CPD-40252 (RA1 475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Upright Pendent Conventional - A-IT, IJ Vertical Sidewall Horizontal Sidewall Recessed PendentjF1/F2 ;/'• - :; Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model Fl FR series sprinklers ,\ are quick-response automatic sprin- klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model Fl FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model Fl FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12. 7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model COP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model GFR2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers, The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers or the use of the Model COP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-RI/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-f actor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Approvals Listings and Approval Notes US Metric inches mm inches mm Pendent 2.25 57 W2 RA14111 cULus 2 F1FR28 2,8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 225 57 W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent - .25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent .25 - 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 Pendent 2.25 57 W2 RA1414 cULus, FM, LPCB, VdS, EC 12,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 12,3,4 Concealed Pendent 2.25 57 GFR2 RA1414 cULus,VdS,EC 5,6 F1FR56 5.6 80 1/2 15 Upright 2.25 57 W2 RA1425 cULus , FM , LPCB, VdS, EC 1,2,3,4 Conventional (Pendent or Upright)' 2.25 57 W2 RA1475 LPCB, VdS, EC 4 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH F1FR56LL 5.6 80 1/2 15 Concealed Pendent 2.25 57 GFR2 RA1415 cULus, ULH 6 Horizontal Sidewall 2,63 67 W2 RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 I (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. 2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3) Available with FM approved Polyester coating in black or white. 4) Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (680c) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model Fl FR56 Concealed Pendent and Model El FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the Fl FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1 FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) I Temp. Rating 175°F (79°C) Temp. Rating I 200°F (93°C) I Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb I Red Bulb I Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I -- _________ Upright cULus Pendent VdS F1FR4O Recessed Pendent VdS I -- Pendent cULus FIFR42 Recessed Pendent cULus I -- _________ Upright cULus Pendent -- cULus, ULH I -- F1FR42LL Recessed Pendent -- cULus, ULH I -- Pendent cULus F1FRXLH Recessed Pendent cULus I -- __________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- I Concealed Pendent* cULus I cULus,VdS,EC I cULus -- FIFRS6 Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC Pendent -- cULus, ULH I -- FIFR56LL Recessed Pendent -- I cULus, ULH I - Concealed Pendent* -- cULus, ULH -- Horizontal Sidewall cULus, FM Fl FR56 Recessed Horizontal Sidewall cULus, FM I -- F1FR56 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model Fl Model F2 Model FP Model (Fig. I & 3) (Fig. I & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 FIFR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS,EC FIFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. 2 7/4" HOLE 0/A. [57.2mm] 1 75/76" 0/A [49.2mm] r TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS- , \ / Fl ESCUTCHEO/'J_ jI7 3/4[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "(25.4mm] AT MINIMUM RECESS = 3/8(9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4719mm] AT MINIMUM RECESS = 3/8[9.5mm] A A El ESCUTCHEON J ¶ AT MAXIMUM RECESS = 7/8[22.2mm] [3.'mm] I 1A MINIMUM RECESS = 1-5/8(41.3mm] ( F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8[28.6mm] IF AT MINIMUM RECESS = 1-5/8(41.3mm] 2 27/32" 0/A. [72.2mm] Model Fl FR56, Fl FR56LL, Fl FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon 1" X 1/2" REDUCER 2 5/8" 0/A. [66.7mm] HOLE ININ CEILING / \ / 2 5/16" 0/A. [58.7mm] CUP CE/UN: FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAX/MUM RECESS = 1-1/2 "[38mm] AT MINIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 1 "[25.4mm] Y2"[12.7mm] J I AT MAX/MUM RECESS = 9/16'114.3mm] ADJUSTMENT ___________ 3 1/4" 0/A. [82.6mm] Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4719mm] AT MINIMUM RECESS = 3/879.5mm] Fl ESCUTCHEON LU AAAVIAAJIAI ppc'cc.ç- = 1-/874 Qmm7 AT MINIMUM RECESS = 2-1116'T52.4mml F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8741.3mm] 1/8" AT MINIMUM RECESS = 2-1/16752.4mm] 3.2mm] ! (1) 4"-12" [101. 6mm-304.8mm] 32 0/A CEILING TO [72.2mm] DEFLECTOR Fl ESCUTCHEON [3/4"[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT 2 1/4" HOLE DIA. [5 7.2mm] 1" X 1/2" REDUCER r ,_Jr 1 15/16" [49.2mm] I I "-- TURN COLLAR UNTIL -, TIGHT AGAINST SPRINKLER WRENCH BOSS. O7JFOJE RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW 2 5/16" 0/A - CUP CEILING -' 1/2" MAX. I COVER ADJUSTMENT COVER PLATE ASSEMBLY 5/16 0/A SPRINKLER - 2 5/8" DIA. I HOLE IN CEILING I 1 1/2" MAX. FACE OF FITTING T / DIMENSION FACE OF CEILING DIMENSION CONCEALED, 1/2" ADJUSTMENT 0I7FG01A Fig.4 Model Fl FR56IF1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate I" x 1/2" REDUCING TEE OR ELBOW —F E 'i' 2 5/16" DIA CUP - r,,: LL..i!J. / i CEILING x -,--- 2 5/8" VIA. HOLE IN CEILING 1 1/2" MAX. - FACE OF FITTING TO FACE OF CEILING FTZ DIMENSION 5/16" MAX. _J 3/4" COVER ADJUSTMENT COVER PLATE -- ASSEMBLY 5/16" DIA. SPRINKLER CONCEALED, 5/16" ADJUSTMENT 017F502A Fig. 5- Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon I Cover plate1 Bronze Brass I Chrome Chrome Plated Chrome Plated I White Polyester Coated (406) White Painted I Specl Application Finishes Sprinkler Escutcheon Cover plate111 Electroless Nickel PTFE7 Electroless Nickel PTFE ng Bright Brass Bright Brass3 Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(21t6) Black Paint Off White Off White (2)(1) 1 Off White I Satin Chrome Chrome Dull I Chrome Dull I Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant Material Data Frame: DZR Brass, OM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR40][F1 FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FRS6LL] Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright] [Conventional] [Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1121 Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79-C)] [200-F (93-C)] [286-F (141°C)] Sprinkler Finish 6, Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment] [low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][ 1 65'F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model Fl FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7' Reliable....For Complete Protection Reliable offers a wide selection of sprinkler components. Following are som e o f t h e m a n y precision-made Reliable products that guard life and property from fire around t h e c l o c k . Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest p u b l i s h e d S t a n d a r d s o f t h e N a t i o n a l F i r e P r o t e c t i o n A s s o c i a t i o n , F a c t o r y Mutual Research Corporation, or other similar organizations and also with the pro v i s i o n s o f g o v e r n m e n t a l c o d e s o r o r d i n a n c e s w h e n e v e r a p p l i c a b l e . Products manufactured and distributed by Reliable have been protecting life and prop e r t y f o r a l m o s t 1 0 0 y e a r s . Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled Reliable (800)431-1588 Sales Offices Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/19 P/N 9999970300