Loading...
HomeMy WebLinkAbout2335 VIA FRANCISCA; BLDG 19; FPC2018-0224; PermitPIERXT REPORT (Cityr of Carlsbad I Nb~) Print Date: 10/05/2022 Permit No: FPC2018-0224 Job Address: 2335 VIA FRANCISCA, CARLSBAD, CA 92008-6824 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 07/19/2018 Valuation: $0.00 Lot 4*: Issued: 08/02/2018 Occupancy Group: Project 4*: Finaled Close Out: 04/15/2021 #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Wong, Cindy Plan Check 4*: Fieri, Dominic Project Title: Description: RESERVE AT CARLSBAD BUILDING 19 -ALARM TI -REPLACE PANEL, PULL STATIONS AND SOUDERS. RELOCATE SOUNDERS FPContractor: ALL COUNTY FIRE PROTECTION INC 10965 SAN DIEGO MISSION RD SAN DIEGO, CA 92108-2431-SAN DIEGO (619) 284-4770 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00. Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov F RJ2-cd - 072-k HIGHLIGHTED SET UL Certificates of Compliance Cut Sheets and CSFM listings: THE RESERVE AT CARLSBAD BUILDING #19 2335 VIA FRANCISCO CARLSBAD, CA 92008 Installation Company: flTu COUNTY ilii SINCE 1975 3163 ADAMS AVENUE SAN DIEGO, CA 92116 Ph. (619) 284-4770 CIO LICENSE #967194 Applicant ID No: 731846-001 Service Center No: 0 Expires: 31-MAR-2019 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Comoanv indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: POWAY, CA Alarm Service Company: (731846-001) Service Center: (731846-001 CENTRAL MONITORING CORP CENTRAL MONITORING CORP SUITE 1-4 SUITE 1-4 14231 GARDEN RD 14231 GARDEN RD POWAY CA 92064 POWAY CA 92064 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category S26691 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31.MAR.2019* "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" DF-52416:D • A3-20 MS-5UD(E)LMS-1 OUD(E) Series) j Flreu-reALarms Five Zone Fire Alarm Control Panel (Ten Zone Fire Alarm Control Panel) by Honeywell General The MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-i OUD-7(E) is a ten-zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 1OUD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterf low devices, tamper switches, and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN-6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD per- mit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-5UD-3E and MS-10UD-7E offers the same fea- tures as the MS-5UD-3 and MS- IOUD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-fisted models, see DF-60440. Features Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter). - MS-5UD-3 - five IDCs. —(MS 1OUD7fiDCiJ tyleY(ClassB)NAC(N5Eifiion Ajli eCi?t spe cial application power - MS-5UD-3 - four NACs. —CMS 7four NACs.) Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. - Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). —CIrnporal or Sf digi) - Silenceable or Nonsilenceable. Optional CAC-5X Style Z (Class A) Converter Module for NACs and IDCs (2 required for MS-10UD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 0.5 A @ 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 0 .Jotal symcurrent for MSf0UDfl Optional Dress Panel DP-51050 Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Up to eight ANN-BUS annunciators: - Optional 8 zone Relay Module ANN-RLY. - Optional LED Annunciator Module ANN-LED, - Optional Remote Annunciator ANN-80. - Optional Remote Printer Gateway ANN-S/PG. - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. DF-52416:D • 07/26/2010 - Pagel of 4 USER INTERFACE: Built-in DACT (Digital Alarm Communicator/Transmitter). Integral 80-character LCD display with backlighting and keypad. Real-time clock/calendar with automatic daylight savings adjustments. ANN-BUS for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power —TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.80 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, 2.20 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower-limited. .t*ry1iied lead acid nly) - J12i Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower-limited. re ximum Charger Capacity: 18 AH battery for TIUEY.) ), and 26 AH battery for MS-1OUD-7(E). [Two 18 Ah bat -) es can be housed in the FACP cabinet. Larger batterie) uLprate battery box such as the BB-26 or BB-55J Top Depth= 5.207"(13.23 cm) Door = 16.821" (42.73 cm) 10 Backbox = 16.65" (42.29 cm) Depth = 3.353 cm) JH Door = 19.26" (48.92 cm) Backbox = 19.0" (48.26 cm) Left Side Right Side Bottom Cabinet Measurements Page 2 of 4— DF-524160 "07/26/2010 Minimum Battery Size: 7 AH. Initiating Device Circuits - TB4 (and TB 6 on MS-i OUD-7 only): Alarm Zones 1 -5 on TB 4 (MS-5UD-3 and MS-i OUD-7). Alarm Zones 6- 10 on TB6 (MS-10UD-7 only). Supervised and power-limited circuitry. Operation: All zones Style B (Class B). Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms. EiLuie Resi r47T(oh31/2 watt (P/N 71252 UL listed). Standby Current: 2 mA. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. (Notification Appliance Circuits)— TB5 (and TB 7 on MS- 101.113-7 only): Four NACs pe ration Y(çss Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0 A for D-7(EI 3.0 A mã) NACJ (E of LihiRèistor 4.7K-ohm 1/2 watt (Part #71252) Max. Wiring Voltage Drop: 2 VDC Refer to the Fire-Lite Device Compatibility Document for com- patible listed devices. Form C Relays - TB8: Relay I (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - TB9: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - TB2: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Product Line Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. ç1S-10UD-7: Ten-zone, 24-volt Fire Alarm Control PaneD jncludes backbox,FL.ES-7 power_suppjtechnical) manual, and a frame & post operating instruction sheet). MS-1 OUD-7E: Same as above with 240 VAC FLPS-7. IPDACT, I12DACT-2/21.11) Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: V Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC-5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style V (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- 7(E) main circuit board and to J7 on the MS-1 OUD-7(E). NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPA TIBLE ANNUNCIA TORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (For white, order: ANN- 80-W.) ANN-LED: LED Annunciator with three LEDs for each zone: Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) dress panel. Red. (For white, order ANN-LED-W.) ANN-RLED: LED Annunciator with three alarm (red) indica- tors for up to 30 input zones or addressable points. (Red. For white, order ANN-LED-W.) (See DF-60241). ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55: Battery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. PRN-6F: UL listed printer. DF-524160 • 07/26/2010 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Annunciators ......................................................................8 Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.0A O tIS-1OUD4 (FLP9-7 Power Spj: 120 VAcIHZ MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Wire size: minimum 14 AWG (2.0 mm 2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26 (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: - 20.00" (50.80 cm.) high —22.5(57.15cm.) wide - 8.5" (21.59 cm.) deep. Weight: 27 lb (12.20 kg) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved MEA: MEA: 333-07-E NOTE: For ULC-listed models, see DF-60440. NFPA Standards The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. I b d U U We cannot cover all specific applications or anticipate all requirements. QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52416:D • 07/26/2010 155 Tea in n its J12j Notification Appliance Circuits (see note 1) Special Application Power Basic System Connections NAC #1 #2, #3 & #4 Style V (Class B) (Supervised. Power- 5-Zone Panel Limited) (See Style Z illustrated near right edge of board.) 4.7K0hm, Y. watt End-of-Line Resistor NAC #1 NAC #2 PN 71252 NAC #3 NAC#4 3 Programmable Relays Dummy load all unused circuits Nonsupervised relay contacts with 4.7KC, M. watt End-of-Line Notes: I EIJ ------ ,--..,"- Ei EJ Contact Ratings am s n ,m n (rj6fi,, resistors MS-5UD-3(E) = 2.5 amps max. per NAC Special Application initiating Device r..Ircutcs a: am3OVAC(r'estwve)' MS-5UD-7(C/E)= 3 amps max. per NAC Power Contacts shown below in normal Remote Sync Output is required only for • lDCs 1 through 5, Style B the MS-5UD-3(E): Refer to "Remote (Class B)) (Supervised, Power-Limited) (See Output (see note 2) Synchronization trouble, or supervisory activity) Synchronization Output" on page 34. Style D illustrated near Special Application A Fail Safe Trouble relay switches 18 Amp Hour max. for MS-5U D-3(E) right edge of board.) 4.7Kohm, 'A watt End-of- Power to the NC position during trouble 24 VDC filtered, conditions and under loss of all 26 Amp Hour max. for MS-5UD-7(E) Line Resistor indentifications for circuits. Remove jumper PN 71252 Remote condition (AC power with no alarm, Style Z (Class A) NAC supervised and power- power. 18 Amp Hour max. for MS-SUD-7C limited. 0.040 amp maximum. Requires ("Factory default relay 4.7K ohm ELR. programming) Important! Removing Ground Fault Disable Jumper JP43 voids UL/NFPA Style/Class Alarm* Trouble' Supervisory' JP43 only with the approval of the local AHJ _______ ________________ (Authority Having Jurisdiction). Style D (Class A) IDC 3 0 OU — 154 Q TV 152 TH 12346 .n1 68.842 A42 Class A Converter Module Cut this iumperto / enable supervisory .J2 i..,...uI I ....iii..j7 $ Relay when 4XTMF Remove jumper JP43 to JP24 module is installed disable Ground Fault Detection circuit (only with t ) approval of AHJ) JP43 2 J3 l.III.IflhI.uIuI - = 29 Battery (see note 3) 24 VDC, supervised, nonpower-limited Special Application DC Power Outputs 24 VDC) Nonsupervised, power-limited circuits Supervise with a power supervision relay EOLR-1 Resettable Power - 24 VDC filtered, power-limited (0.5 amp maximum) t014_ smoke detectors (lDC). Supervision 13— required. Nonresettable or Resettable Power {2 Jumper selectable by JP31, 24 VDC 1 filtered, power-limited (0.5 amp maximum). Supervision required. Nonresettable Power suitable for powering smoke detectors. Configure T139, Terminals I & 2 as Resettable or Nonresettable Power. Resettable Power - jumper JP31 pins 2 &3 Nonresettable Power-jumper JP31 pins 1 & 2 (as shown) For more specific UL wiring information, refer to page 35. Power Supply Push switch down to Kiss-off LED upgrade software Auxiliary JP3O Trouble Input U Cut this jumper to supervise the 4XTMF module when installed (see J4 & J5) .113 .111 ANN-SEC option card connector Primary Phone Secondary Phone Active LED Active LED 0 Eff 668 8 6 0 Primary Secondary 0 DACT Phone Line Jacks Nonpower-Limited Class A Converter Module USE: port for local programming using a personal computer and PK-5X Utility 3 Notification Appliance Circuits (see note 1) Special Application Power NAC #1,52, #3, & #4, Style V (Class B) (Supervised, Power- Limited) (See Style Z illustrated near right edge of board.) 4.7Kohm, 'A watt End-of-Line Resistor NAC #1 NAC #2 PN71252 NAC #3 NAC 94 Initiating Device Circuits lDCs 1 through 5, Style B Nonsupervised relay contacts with 4.7KQ, 1/2 watt End-of-Line Initiating Device Circuits Special Application Power 3 Programmable Relays Dummy load all unused circuits Special Application I I (Class B) (Supervised, Power- Special (See Style D Contact Ratings resistors Power @IDCs 1 through 5, Style B _I) illustrated near right edge of 2.0 amps @ 30 VDC (resistive) l,oarefl -- 0.5 amp @30 VAC (resistive) Style Z (Class A) NAC Basic System Connections 10-Zone Panel Notes: MS-10UD-3(E) = 2.5 amps max. per NAC MS-i OUD-7(C/E) = 3 amps max. per NAC Remote Sync Output is required only for the MS-10UD-3(E): refer to "Remote Synchronization Output" on page 34. 18 Amp Hour max. for MS-I OUD-3(E) 26 Amp Hour max. for MS-I0UD-7(E) 18 Amp Hour max. for MS-10UD-7C Important! Removing Ground Fault Disable Jumper JP43 voids UL/NFPA Style/Class indentifications for circuits. Remove jumper JP43 only with the approval of the local AHJ (Authority Having Jurisdiction). Special Application DC Power Outputs 24 VDC) Nonsupervised, power-limited circuits Supervise with a power supervision relay EOLR-i Resettable Power - 24 VDC filtered, power-limited (0.5 amp maximum) t014_ smoke detectors (lDC). Supervision 13— required. Nonresettable or Resettable Power {2 Jumper selectable by JP31, 24 VDC 1 filtered, power-limited (0.5 amp maximum). Supervision required. Nonresettable Power suitable for powering smoke detectors. Configure TBD, Terminals 1 & 2 as Resettable or Nonresettable Power. Resettable Power-jumper JP31 pins 2 &3 Nonresettable Power-jumper JP31 pins 1 & 2 (as shown) For more specific UL wiring information, refer to page 35. Power Supply o o '184 TE — 2000 zee Z20 Z0ic 00Th 0014 0020 0220 20 2022 0020 C IC IC C 121200 I 2 0 4 I I 0 II R0IAYI 004.013 20.002 Class A Converter Module Cut this umperto / enable upervisory _______ II•uIIuuIJ7 A&' Relay when 4XTMF J2 iiiu.i.0 ________ Remove jumper JP43 to JP24 module is installed disable Ground Fault ) t4 Detection circuit (only with . approval of AHJ) ~J SWI Push Switch down to upgrade software .js Kiss-off LED JIM D Auxiliary • L1 Trouble Input N Cut this jumper to supervise El the 4XTMF module when installed (see J4 & J5) J13 Jil ANN-SEC option card connector Primary Phone Secondary Phone Active LED Active LED 0 -+0203022 01Cee4, 0 2 is 4, Primary Secondary C DACT Phone Line Jacks Nonpower-Limited U HI Battery (see note 3) 24 VDC, supervised, nonpower-limited Power B) (supervised, .. r,uo,,,, Resistor Contacts shown below in normal r -Limited) (See PN 71252 condition (AC power with no alarm, Style D illustrated near trouble, or supervisory activity) 4.7K0hm. 'A wad Endf- Synchronization A Fail Safe Trouble relay switches to right edge of board.) Remote Line Resistor Output (see note 2) the NC position during trouble 00200 PH 71252 Special Application Power conditions and under loss of all 24 VDC filtered, supervised, power. and power-limited. 0.040 amp maximum. Requires 4.7K ohm ELR. ("Factory default relay programming) Alarm Trouble" Sopervioery 111111111 15 Class A Converter Module USB port for local programming using a personal computer and PK-5X Utility 3 Power Supply Calculations Calculating the System Current Draw Table 7.3 contains three columns for calculating current draws. For maximum output current avail- ability per circuit and per panel, refer to Section 1.2, "Specifications", on page 15. For each col- umn, calculate the current and enter the total (in amperes) in the bottom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 121. Calculation Column I Calculation Column 2 Calculation Column 3 Device Type Primary, Non-Fire Alarm Current Secondary, Fire Alarm Current Secondary, Non-Fire Alarm (amps) (amps) Current (amps) aty I X[current I Total I Qty X [current draw] I Total I Qty X[current I I Total draw]= I - - I I draw] I Main Circuit Board MS-5UD X[O.110]= X[O.214]1 2 x[o.11o]= or tvlS-1OUD) X[O.133]= 1 = JP 131i CAC-5X F ] X[0.001]= ] X[0.001]= [ ] X[0.001]= 4XTMF F ] X[0.005]= [ ] X[0.011]1= [ ] X[O.005]= 1 max. I max. 1 max. ANN-SEC card [ ] X[O.003]= [ ] X[O.003] [ ] X[0.003] 1 max. 1 max. I max. ANN-80(C) - - X[O.037]= LI X[0.040]= [ X[0.015]= ANN-I/O ] X[O.035]= (] X[O.200]= [ X[O.035]= ANN-RLY X[O.015]= [] X[O.075= [ X[O.015]= ANN-(R)LED - X[O.028]= [] X[O.068= [ X[O.028]= ANN-S/PG - - X[O.045]= [] X[0.045]= [ X[O.045]= 2-wire Detector - - X[ ]4= [l X[0.040] ( X[ ] Heads 4-wire Detector [ ] X[ ]4=[ ]5 X[0.040] F I X[ ] Heads Power [ ] X[0.025]= [ ] X[O.025] F I X[O.025]= Supervision Relays6 I I I NAC #1 [ ] X[ 1 NAC #2 I ] X1 1= NAC #3 NAC #4 Current Draw F ]= F 1= [ 1= from TB9 (nonalarm) Sum each column for Primary Non-Alarm = Secondary Alarm = Secondary Non-Alarm = totals Table 7.3 System Current Draw Calculations If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. The current draw shown represents one zone (lDC) on the main circuit board in alarm. One zone consumes 0.040 amps. An ANN-LED is supplied standard with the MS-5UDC and MS-1 OuDC. Refer to the Device Compatibility Document for standby current. Enter the number of lDCs used minus one. Must use compatible listed Power Supervision Relay. Total current draw listed above cannot exceed 3.25 amps for the MS-5UD-3(E), 3.28 for the MS-iou D-3(E), 7.25 for the MS-5uD-7(C/E), and 7.28 for the MS-10UD-7(C/E). 120 MS-5UD & MS-lOUD Series Manual - PIN 52626:C5 7/16/2014 NFPA Standard-Specific Requirements The following figure illustrates an example of Central Station/Remote Station Reporting using a 4I1UD. The relay contacts from the MS-5UID/MS-1OUD maybe used to trip any dialer UL listed for Central Station/Remote Station Reporting Services. 411 UD Channe U10 IM o US PHI Channel uii __ 0 Channel 4(2.2K ELR)— - - 8 I 1 o Jumper -VDC to Trouble Relay contact - R41 [] + 24 VDC nonresettable power PH2 - 24 VDC nonresettable power O o [1 ITT 0191 J4'._ —J4 Not Installed 2.2K ELRs PIN 27070 —-r'i ni in P.' L-WZLIZ'I TB7 TBS TB4__________ a o OTh2 T68 0 Q 196 I.I. IS• It. IlS It. UI.II. S*S. tS. SII•RII.l*. LXfIRELAY2R!LAY2 OUTI OUT2 Z!ZONEZ1!ZON!TOI! OUTS 0UT4 -ZeNEzOE ZONE ZONE ZOOE [J j J2 t._..__.t H H! Ha Th9 JP31 t: Mot STAUX U 0 ISTSNONflST ff1TTTlTIl JP30 __ Qo I I FACP Trouble Input (non-supervised, power-limited) Figure B.1 MS-5UD/MS-IOUD FACP Connection to 4IIUD 411U0 FACP Alarm TB2-1 TB8-1 TB2-2 TB8-3 Trouble TB2-3 T138-4 TB2-4 TB8-6 Supervisory TB2-5 TB8-7 T132-6 T138-9 Table B.1 411 U Connections to FACP 128 MS-5UD & MS-lOUD Series Manual - P/N 52626:C5 7/16/2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7165-0075:0214) Page 1 of 1 CATEGORY: (165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)) LISTEE:(FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653) Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Model MS-5UD-3,_MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E, MS-10UD-3, MS-10UD-3E,MS-10Up MS-IOU D-7C AND MS10-UD-7E(Fire alarm control units The MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. * These Models are intended for the following applications: Local, Auxiliary, Remote station, Central Station, and Proprietary. Refer to listee's data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module "ANNSEC Secondary ANN-BUS Module *lpDACT; IP Digital Fire Alarm Communicatior RATING: *120 VAC or 230 VAC primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. "Rev 04-23-15 gt * This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 QistiiJJ (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TG-7FS) '1LTE-V{T' P/N: TG7LVF01 CICELLULAR AA* FOR LTE NETWORKS TELGUARD a COMMERCIAL FIRE PRODUCT FEATURES (Certified for use on Verizon's LTE networkjfor long, sunset- free installation. U- Meets UL 864 requirements for sole, primary or backup path communications. 1- Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS LTE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new sixty minute supervision mode. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. uard Portal URM—ardrGTI lije a i;ittffir 1tEt itt -.j iiiiJ 11!II a ( Rjjjrj ZA1 lV i t Ct!1 X' o f&iit tj 1U1E [ 1Iii) ii1i ijJix \C UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems For the most current product specifications and UL Listings Visit www.Telguard.com. TG-7FS LTE-V P/N: TG7LVFO1 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD Lw..er Transmit1ower Power Consumption: 6OmA (Standby) 250mA (Transmission). • isce1er LTEIB's 3. !tenna '_ipole 12c___e gai, Cl aniietsal moun ing CKe. k68Icompliant ii s #Ig8L ocodep igg Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 USA 800-229-2326, Option 5 www.Telguard.com • Copyright ©2017 Telular Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: (7300-1402:0110) Page 1 of 1 0 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES) LISTEE: ELULAR CORP.322 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models *TG7LVO01 *TG7LVA0I U37Lj)and TG-KIT, cellular communicator) y)ModeIs are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04072017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 fitit 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division p Ilk f", A BW-Doc ox B -- - -- BW-DocBox (1511Wx 1311Hx4"D) • _• includes: - Threelabels: "Fire Alarm Documents" As-Built Permits "Test and Maintenance Documents" An adjustable bungee allows you to fit various sizes of binders, _.: . . .............. documents, smoke cans etc it _____ A door bracket holds two CDs, three . . Four boxes sets of keys and more documents .' .. in • J The door can A cam lock with two keys P be or one of the BW-DocBox2 (1111Wx 1511Hx411 D) three abels Smaller and more basic model without the door bracket . II I e used. for CDs and key sets. However, it does have the three labels, adjustable bungee and a lock with two keys. Don't see the box you want? Customization, special colors, and/or silk-screening of logos are Call us or visit our website available for quantities of 25 or more. (requires lead time) e 800-473-0213 E-mail: info@mierproducts.com SYSTEM S SENSOR® 5600 Series)____ Mechanical Heat Detectors) System Sensor's 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Oi/X4 5601P * 5621 Features Multiple configurations for installations: - Single- and dual-circuit models - Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601P) Easy-to-use terminal screws A broad range of back box mounting options: - Single gang - 3.5-and 4" Octagonal - 4" square with square to round plaster ring Reversible mounting bracket Agency Listings @ <~> g LISTED APPROVED 0 S2101 3016008 C0630 7270-16530167 Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (BOA) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Specifications Mechanical heat detector shall be a System Sensor 5600 series model number ________ listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 1 4-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Maximum Installation Temperature 5601 F, 5603, 5621, and 5623: 100°F (38°C) 5602. 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 F, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601 F, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Operating Voltage / Contact 6-125VAC / 3A Ratings 6-28V0C / 1A 125VDC/0.3A 250VDC/0.1A Input Terminals 14-22 AWG 5601 P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information 5602 Single Lettering 194°F (90°C) Fixed Temperature /Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature I Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) 51"slEIv7 EIL.cOR 3825 Ohio Avenue • St. Charles, IL 60174 ©2013 System Sensor. Phone. 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change e.ithout no/ce. Vail systemsenscr.cunl for current product information. including the latest version at this data sheet. www.systemserisor.com SPDS30001 • 7/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7270-1653:0167) Page 1 of I CATEGORY: (7270 -- HEAT DETECTOI) LISTEE:(System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, ) 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models 5601 ,(601 P35602, 5621, and 5622(combi nation -temperature rate-of-rise _fixed _and GR and Models 5603, 5604, 5623, and 5624 fixed-temperature mechanical(heat detecto) Refer to listee's data sheet for detailed product description and operational considerations. RATING: Models 5601, 5601P, 5603, 5621, & 5623 have a fixed temperature of 135°F. Models 5602, 5604, 5622, & 5624 have a fixed temperature of 194°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, temperature/electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details and UL directory for dimensions. NOTE: Formerly 7270-1209:227 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Ds (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division With the door and backplate aligned and 'keyed' together, slide the holes down onto the posts. Closing the door slightly locks the door and backplate together. 8 FureLiTeALarms Dual Action BG-12LOB Description The BG-12LOB Pull Station is anon-coded manual pull station which provides a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The pull station is a dual action model equipped with a key lock reset, an approved outdoor gasket, and an accompanying outdoor backbox. It is UL listed and meets the ADA requirement of a 5-lb. maximum pull down force to activate. Operating instructions are molded into the handle. Molded terminal numbers can also be found adjacent to the wiring terminals. BG-12LOB The features of the pull station include Dual-Action operation, Key-Lock Reset function, Screw Terminal Wire connections, outdoor use gasket, a WBB outdoor approved 4-inch backbox, and a sealed switch with gold-plated switch contacts. Note: The BG-12LOB is applicable with the WP-10 backbox in retrofit applications. To meet UL requirements for outdoor use, the BG-12L0 Pull Station must be mounted to the WBB or WP-10 Backbox to create the BG-12LOB model. Switch Contact Rating FACP Circuit (Terminals 1 & 2): Rated to .25 Amp at 30 Volts (AC or DC). (UtëWlöiOiTtiloor AijIiãiii Document E.1373 Revision A ECN 00-215 06/13/2000 Door Attachment If the door becomes detached, complete the following steps to reattach the door to the backplate. The door cannot be connected to the pull station if the unit is mounted to a backbox. Door mated to Backplate at this stage. Position the door and backplate side by side in the full open position. (i.e. 180-degrees with respect to each other.) With the backplate position fixed, move the door behind the backplate, as shown in the illustration, part A. Align the hinge posts and holes by bringing the door up to meet the backplate, paying particular attention to the 'keying' that occurs when the door's post hole is aligned to the backplate's hinge post. Refer to the illustration, part B. With the two pieces aligned and 'keyed' together, slide the holes down onto the posts. Refer to the illustration, part C. Holding the backplate, close the door slightly to lock the door and backplate together. BG-1 2LOB Pull Station (Shown Activated) Wiring Instructions Surface mount the supplied Outdoor Backbox (WBB) using the side flanges incorporate into the backbox design. The box can be positioned to allow conduit connection from any side. The pull station will mount in any position desired. Before mounting the pull station, pull all necessary wiring through the backbox. Remove the correct amount of wire insulation. The pull station's backplate is molded with a strip gauge to measure the amount of insulation to be removed. Connect the wiring from the fire alarm control panel's Initiating Device Circuit (IDC), or any previous device on the IDC to terminals 1 and 2 located on the pull station's terminal strip. Connect the next device on the IDC or End- of-Line Resistor (ELR) to terminals 1 and 2. Note: Maintain consistent polarity with all connections throughout the IDC. Outdoor Stations Install the BG-12L0 with a listed, outdoor-approved backbox (WBB or WP-10) to meet UL requirements for outdoor use. Without one of these backboxes, the BG-12L0 is not listed for outdoor applications. Use the four supplied 8-32 x .375" mounting screws to attach the Pull Station to the outdoor- approved backbox. BG-1 2L0 + WBB = BG-12LOB Next Device Operation To activate the dual-action station, first push in the handle, and then pull the handle down. The handle locks into the activated position. The word 'ACTIVATED' appears after the handle is pulled down. The pull station remains in the activated position until reset with the key lock. Outdoor-Use Gasket (Does not cover any user-serviced connections) Reset the BG-I2LOB by inserting the key into the lock and turning it 1/4 turn (counter-clockwise). Open the door until the handle returns to the 'NORMAL' position. Close and lock the door. Closing the door auto- matically resets the switch to the 'NORMAL' posi- tion. Note: Opening the pull station door will not activate or deactivate the FACP alarm switch. From FACP IDC CAIJHON Ins tall the pull station in accordance with the supplied instructions, applicable NFPA standards, national and local Fire and Electrical codes and the requirements of the Authority Having Jurisdiction (AHJ). Conduct regular testing of the devices using appropriate NFPA standards. Fire-Lite is not responsible for devices that have not been properly installed, tested or maintained. For ADA compliance, if the clear floor space only allows forward approach to an object, the maximum forward reach height allowed is 48 inches (121.92cm). If the clear floor space allows parallel approach by a person in a wheelchair, the maximum side reach height allowed is 54 inches (137.16cm). Document 51378 Revision A ECN 00-215 06/16/2000 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 50-0075:) Page 1 of 1 CATEGORY: (7150-- FIRE ALARM PULL BOXES) LISTEE:(FIRE-LITE ALARMS lNC.On)Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-I2LW, BG-12WP, BG-I2LWP, BG-12L, BG-12LX, BG-12LA, BG-I2PS,_BG-12LSP, BG-12SP, BG-I2LR, BG-12LRA, BG-12LAO, BG-12LAOB,_BG-12-L0,(BG-12L0B)BG-12LPS, BG-12LPSP, BG-12SL, UT-PSi and UT-PS2(Tre pull boxes)The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-1 2WP, BG-1 2W, BG-1 2LW and BG-1 2LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB anc(BG-12LOB are intended for) (outdoor use when installed with Model WBB or WP-1 0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (Lis Ling pe Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Product Listings SIGNALING - c®ijs LISTED ANSI/UL 464 Listed CAN/ULC 5525 Listed CSFM: 7135-0569:0148 Product Compliance NFPA72 IBC/IFC/IRC Quality Management System is certified to: ISO 9001:2008 (GHLF 24 VDC Series)__ 24 VDC 520 Hz square wave audible 24 units per carton, 28 pounds per carton Applications The GHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The GHLF is ideal for any occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave, temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4" metal mounting plate which incorporates the popular Super-Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate® - Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire protective systems and is warranted for three years from date of purchase. Standard Features Nominal voltage 24 VDC Unit Dimensions: 6-1/8" (15.55 cm) high x 5-1/2" (13.97 cm) wide x 1-5/8" (4.13 cm) deep Super-Slide® Bracket - Ease of Supervision Testing Checkmate® - Instant Voltage Verification Synchronize horn with Gentex GTSM Synchronization Control Module Prewire entire system, install mounting bracket, then install signals Input terminals accept 12to18AWG Produces a 520Hz square wave, temporal 3 tone Jumper selection for normal or loud dBA Temporal 4 pattern available when used with Gentex GTSM Synchronization Module Temporal 4 520H measured per ANSI/UL 2075 Tamperproof re-entrant style grill and locking screw (optional use) Faceplate available in red or off-white Model Part Number Nominal voltage (VDC) 1=11 I I=M1 GHLFR 904-0531-002 24 - R= Red Faceplate, W= White Faceplate. All units are plain (no lettering). Horn Decibel Levels: I Horn Current Ratings Reverberant Room (dBA) DrNomiiiiJHorr. Current Ratirj Over Input Voltage Range of 16-33V (mA) Minimum Minimum 24VDC 24VFWR 24VFWR Regulated Regulated Regulated 24VFWR Regulated 24VFWR lEioLnMQ SPLat loft. SPLat loft. Per Per pelratin Operating Operating Operating 24VDCMax. 24VDCMax. Max. Max. ANSI/UL 464 ANSI/UL 464 tCurrent Current Current Current Operating Current Operating Current Operating I Operating (NORMAL) (LOUD) iORt.4j (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) Current Current (NORMAL),J (LOUD) QLHJ 77.8 cIBA 78dBA m 120.1 mA 104.6 mA 158AmA 99.4 mA 155.8 mA 152.1 mA 213.5 mA Temporal 520 Hz* 81.5dBA 83.4dBA 75.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 =mA157.2A 163.1 mA 235.2 mA Tempora14 520 Hz measured perANSf/UL 2075 Do Dot PAINT T H— 1-5/8" 4.2 cm Notes Operating temperature: 32° to 120°F (0° to 49°C) The GHLF is not listed for outdoor use For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating This appliance is not recommended for use on coded or pulsing signaling circuits The four pulse temporal pattern (temporal 4) can only be obtained on this product when used in conjunction with the Gentex GTSM synchronization module See GTSM control module manual (550-0632, manual issue date (02-01-15) for synchronization module wiring diagrams. GTSM manual can be obtained at www.gentex.com/fire, or call Geritex Corporation at 1-800-436-8391 UL Listed Control Panel , signal Signal Supervised lip - - (c € J E Signal Circuit U Red Wires 0 Black Wires Optional Loud Decibel Install \Jumper 0 ~Fco 0;~~ END OF LINE RESISTOR GHLF - Low Frequency Audible Signal GHLF 24 VDC Series Low Frequency Audible Signal Gentex Super-Slide® Mounting Bracket Architect & Engineering Specifications Allows the installer to prewire the system, test for system supervision, remove the signal head until occupancy, switch out Gentex signals without changing mounting brackets and has locking edge connector for snap-in-place installation. Gentex Checkmate® Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. Notice: Care should be taken to not short the test probes. The alarm horns shall be Gentex model GHLF. The appliance shall be listed with Underwriters Laboratories (ANSI/UL) for use with fire protective signaling systems ANSI/UL 464 and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The GHLF shall be mounted on the wall or the ceiling. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7135-0569:0148) Page 1 of 1 CATEGORY: 17135 --- AUDIBLE DEVICES LISTEE: (Gentex Corporation 10985 Chicago Drive, Zeeland, MI 49464 Contact: Keiffer Sestric (616) 392-7195 Fax (616) 392-4219 Email: keiffer.sestricgentex.com DESIGN: (Model GHLF low frequency j n.) The model may be followed by a letter indicating product color. *Models GHSLF-15, GHSLF-110 and GHSLF-177_low frequency horn/strobes. *Horn/strobes models maybe followed byor -R(()or red). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VdcNFWR *Model GHSLF-15 15 candela fixed *Model GHSLF-110 liO candela fixed *Model GHSLF-177 177 candela fixed INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a low frequency horn or* low frequency horn/strobe when used with a separately listed electrically compatible fire alarm control unit. Horn/strobe models for wall mount only. All models are for indoor use only. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee's Installation Instructions Manual for details. *Rev 07-11-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 igExpJJ (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division PP_ 000 COOPER Notification (Series MB Motor Bells) 0 RR SSP EMOTE PLATE Description The Wheelock Series MB Motor Bells provide a better engineered motor bell for fire and life safety alarm systems. The Wheelock Series MB Bells include higher dBA, low current draw, built-in trimplate for semi-flush mounting, low frequency aluminum shells, and low RFI noise. The motor for Series MB Bells is a durable, high torque permanent magnet motor selected for its high performance and long life. Features Approvals include: UL Standard 464, Factory Mutual (FM), Califor nia State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) Meets OSHA 29 Part 1910.165 High sound output with low current draw Low frequency aluminum shells for better audibility through walls, doors and other structures These DC vibrating Series MB Motor Bells are offered in 6" • 6" and 10" shell sizes in 12 0r24 VDC models and 10" shell sizes in both 12 and 24 VDC models. Series RSSP Sync/Non-Sync retrofit plates are used in conjunction with the Series MB Motor Bell when combination appliances are required. The Series RSSP retrofit plates are available with either Multi-Candela or single candela strobes and easily mount to a 4" square or Wheelock SBL-2 backbox. All Series RSSP strobe appliances meet or exceed the requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard forAccessible and Usable Buildings and Facilities), ADA (Americans with Disabilities Act) and UL Standard 1971 (Signaling Devices for the Hearing Impaired). Integral RFI suppression to minimize included noise on the NAC circuit Mounting options for surface, semi-flush, outdoor, and concealed conduit installation Built-in trimplate makes semi-flush mounting simpler and less expensive Screw terminals permit fast in-outfield wiring of #12 to 18 AWG wire Polarized for DC supervision of NAC circuits Operates on filtered or unfiltered DC The Series RSSP retrofit plates may be synchronized when • For combined audible (bell) and visual signaling, convenient retrofit installed with the Wheelock Series DSM, Sync Modules or plate assemblies are available with Multi-Candela or Single candela Wheelock Power Supplies with Wheelock patented sync strobes (Refer to Fire Alarm Products Catalog for Series RSSP protocol. Wheelock synchronized strobes offer an easy way Sync/Non-Sync Strobes specifications and technical information) to comply with ADA requirements concerning photo-sensitive epilepsy. Ordering Information Model Number Order Code Shell Size Input Voltage (VDC) Average RMS Current UL Max* dBA 10 Ft Mounting Options MB-G6-12-R 3942 6" 12 0.060 0.090 92 0.040 D E J K N 0 PR S MB-G6-12-S 4221 6" 12 0.060 0.090 MB-G6-24-R 3941 6" 24 0.030 0.040 MB-G6-24-S 4222 6" 24 0.030 0.040 MB-G10-12-R 3944 10" 12 0.060 0.090 MB-GIO-12-S 4223 10" 12 0.060 0.090 MBGIO24R) (3943) (io) 4) O30) k040) MB-GI0-24-S 1 4224 1 10" 1 24 1 0.030 NOTES: Typical dBA at 10 feet is measured in an anechoic chamber. For bells all 12 VDC models are UL rated for 9.0 to 15.6 VDC and all 24 VDC models for 18.0 to 31.0 VDC. 47 17) U,'L 51 MEA APPROVED E5946 151-92-E 7135-0785:113 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Fig. I Bell Models + - FROM TO NEXT PRECEDING APPLIANCE ____________ APPLIANCE } OR END-OF-LINE OR FACP RESISTOR (EOLR) S1500 MB 06/11 Notification Cooper Notification is Wheelock* (MEDJ SAFEPATH WAv Architects and Engineers Specifications (The alar aces shall be Wheelock Series MB vibrating Motor Bells)oLt ed equal. They shall be UL Standard 464 Listed for Fire Protective Service. Shells shall be aluminum in 6" or 10" diameter, (ound output at 10 feet shall be 92 dBA) The bells shall incorporate a ,permanentmagjtjnotor and suQpression circuitry to minimize RFT1liey shall include a built-in trimplate for semi flush) (mounting to a standard 4" square backbox, or surface mounting to WheeIk)indoor BB backbox or(utdoor WBB backbox) For bell strobe applications, retrofit plates Wheelock Series RSSP with Multi-Candela or Single Candela strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in-out field wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be textured enamel. Model Number Order Code Nominal Voltage (VDC) Strobe Candela Average Current (AMPS) at listed VDC UL Max* Mounting Options RSSP-24MCW-FR 9402 24 15/30/75/110 .041/.063/.109/.140 .060/.092/.165/.220 D,E,Z RSSP-241575W-FR 7793 24 15 (75 on-axis) .060 .090 D,E,Z RSSP-121575W-FR 7798 12 15 (75 on-axis) .152 .255 D,E,Z * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Fig. 2 Retrofit Strobe Plate Models (RSSP) AUDIBLE STROBE FROM APP _ifl1 _____ PRECEDING - - TONEXT UANCEOR + FACP APPLIANCE .4-. CREOLE FROM TO NEXT - PRECEDING I STROBEOR STROBE OR + + EOI.D FACP Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 35-0785:01 Page 1 of 1 CATEGORY: 7135 --(AUDIBLE DEVICES) LISTEE: perWheeIock_lncY246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: MB series bells)and Model MBS series bell/strobes.1odels MB are suitablej) rodel utdoor use when used with Model WBB bacj) Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires) (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Terminals Faston tab: 187 A = oo Id INCS{ = Mlvi 'll 50 0-35 .155 470 124 ii 59 1.50 031 0.8G 020 050 .004 0.10 I FEATURES Superb recovery from deep discharge. Electrolyte suspension system. Gas Recombination. Multipurpose: Float or.Cyclic use. Usable in any orientation Superior energy density. Lead calcium grids for extended life. Manufactured World wide. Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension ystem incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Low Maintenance Operation Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free. Fi- - 11 yL)AS' S. Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. General Specifications Nominal Capacity (Ah) N P7-12 20hrto1.75vpc300C 7 I Dlii to 1 .75vpc 20°C - 6.4 5hrto I70vpc 20°C 5.9 1 hr to 1 .60vpc200C 4.2 Voltage 12 Energy Density (WnL.20hr) 91 Specific Energy (va-k.20hr) 32 Int. Resistance (m.Ohms) 25 Maximum discharge (A) 40/75 Short Circuit current (A) 210 Dimensions (mm) Length 151 Width 65 Height overall 97.5 Weight (Kg) 2.65 Terminal ND Layout 4 Terminal Torque Nm - _NP SERIES - NP7-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years of experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. Layout E) FastOn tab: 250 D IXCIH-- VIM I-I I I .250 6.35 .031 0.8 I T .020 0.5 9.0 MINUTES - HOURS DISCHARGE TIME FLOAT SERVICE LIFE NP RANGE (AH%) 7051946 CONOIS1ONSIFLOABND VO4SAGE 2 2755PC AM8EJITTEIPERASIJREOC(58'Fl0 72F) Cc 15, < 1 U U. 0 UI 00 <UI Ui0. NP SERIES- NP7-12 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications. Separators = The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials. CYCLIC RECHARGE REGIME • 9.3 550 17 - so 02 NP DISCHARGE CHARACTERISTICS CURVES AT 252C (77°F) FOR 12V FOR OV hotosC Gheo C8p8T05 MAMA BS 8805 IMnoly In AR BATTERY BATTERY 13.0 NP ATOTGIPITF) 19.01 JJ ___ Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge - 15°C to 50°C Discharge - 20°C to 60°C Storage - 20°C to 50°C (fully charged battery) SELF DISCHARGE CHARACTERISTICS .Oi 100 75 7 00 (ITRY) 25 i ..:T is III STO t2 RAGE Tk,E (NIONThSI FLOAT CHARGE CHARACTERISTICS r 0250A"0.27SVPC CONSTANT VOLTAGE CHARGING (VT I AIBIEC 04F( 40 0-25 27 ITO 0.20 CCV so 00 0 1 40 o 9.05 Mo o TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE RESTING C000ITI0951 DISCHARGE CU lINT 0.505 Solo (F.V 5.20 CELL CHARGING CONTENT 0.000Aolo UI CHARGING 00141120 125% OF UISCtIARGEO CAPACITY lANA) AMBIENT TEMPERATURE 7O'C TO 25C (€0F TO 270) 0 0 de 100% DOD 50% DOD 30', oor OF SlOOP URY NUMBER Yuasa Battery Inc. 2901 Montrose Ave Laureldale, PA 19605 www.yuasabattenes.com Registered number 1548820 Cat. NoJ NP7-12 January 08 Distributed by NP SERIES-NP 12-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery field to produce the optimum design of Sealed. Lead Acid batteries. FEATURES : .;• Superb recovery from deep discharge. Electrolyte suspension system. . Gas Recombination. MtiItiniirnns Float or Cvclic use PP Usable in any orientation. Terminals Superior energy density. . NO batteries are manufactured using a range of terminals which Lead calcium grids for extended life. . : vary in size and type. Please refer to details as shown. Manufactured World wide. Application specific designs. Operation An any Orientation The combination of sealed construction and Yuäsa's unique Techni cal Features ...electrolyte suspension system. allows operation in any . orientation, with no loss of performance or fear of electrolyte Sealed Construction . . leakage. Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Valve Regulated Design The batteries are equipped with a simple, safe, low pressure Electrolyte Suspension System venting system which releases excess gas. and automatically All NP batteries utilize Yuasa's unique electrolyte suspension reseals should there be a build up of gas within the battery due system incorporating a microfine glass mat to retain the to severe overcharge. Note. On no account should the battery be maximum amount of electrolyte in the cells. The electrolyte is charged in a sealed container. retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Low Maintenance Operation Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free. Terminals Faston tab: 250 D 250 .004 020 dL INCH MM l .020 0.5 -H. 031 General Specifications Nominal Capacity (Ah) NPI2-12 20hrto1.75vpc300C 12 1Ohrtol.75vpc200C 11.1 5hrtol.70vpc200C 10 lhrtol .60vpc200C 7.2 Voltage 12 Energy Density (\M.L20hr) 1 04 Specific Energy (Wn.k9.20hr) 36 Int. Resistance (m.ohms) 16 Maximum discharge (A) 75 Short Circuit current (A) 360 Dimensions (mm) Length 151 Width 98 Height overall 97.5 Weight (Kg) 4.05 Terminal D Layout 4 Terminal Torque Nm U I LdVU I. e ..•.• ...: .......'.... NP SERIES -NP 12-12 ____ Lead Calcium Grids Long shelf Life The heavy duty lead calcium alloy grids provide an extra margin The extremely low self discharge rate allows the battery to be of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. . stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Long Cycle Service, Life . . . Operating Temperature Range Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. . The batteries can be used over a broad temperature range . permitting considerable flexibility in system design and 1 Float Service Life location. . Charge —150Cto50°C The expected service life is five years in float applications. : . . . Discharge 20°C to 60°C . Storage - - 20°C tb 50°C (fully charged battery) . . .. . . dFdLUF . . . . ., The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials. SELF DISCHARGE CHARACTERISTICS C) N - 40C(10411 05 v3RArc ON_ 004410) NP DISCHARGE CHARACTERISTICS CURVES AT 25°C (77°F) 04 // FORSV NotrG..OlvBncp tIll 0-I 1-I IV 00 l'04 01TCflV02TT(fl - VI' 01. at- 44 J 4,U)0l 4 Vo SIINJTES HojEs lIVE- FLOAT SERVICE LIFE NP RANGE 44) I 0) S l,54J00,5 1141) 10 10L 001500 AN'.) 'C(sTT[s,o'urE2:c 5'4T18 10') 120 TH I FF I1FAP'4) FLOAT CHARGE CHARACTERISTICS H oV 3 0.25CA- 0.275V0C COS-.51AMT VO(TAGF C)-45F5l4C) I ,CAI 4) -. ATOO'C ,68T) 025 0.50 CI''_'0 u','C 15.0 IX 020 0 - 020 7 - A lEE- 140 ObCIISFEL 0.10 I - - LIE 2I' L'N_'EAGO lOt 11 0 N N - - C0flll.SI\SçJV.04'ç C10411,lldo 5I"L 'ICE-OS TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE II '0541, 004 1111055 DII (lIDS' 1- (.2111111.1 0.110 Asp. 00/1040, CL CIEAOCI%C, 0200055 0.050*0-0 Co'O.ROINIE v0L5lk'E 25'. OF 01040003C) CAP5CI'V DM1111-pEr 10.'oFFlATORE 0-0-4 10? C (04 F 0, ?F'F) ('3(1 000404-' 4101 0 1D1/000 OF ('SPIED _PA if .•--.... . . Distributed by YUASA T Ud* odl.LeI y Inc.i 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 Cat No. NP 12-12 March 091 EOMTR4N 'Corporation 17 RISER FIRE ALARM CABLE FLAME RETARDANT PVC JACKET UL TYPE FPLRICMRICL3R C(UL) CMG 300 VOLT APPLICATIONS: Fire Alarm, Signal Monitor/Detection Audio or Control Circuits 22 AWG Solid Bare Copper, Insulation Thickness: .006" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches 4304 2 .014 0.120 18 AWG Solid Bare Copper, Insulation Thickness; .009" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches (i44 4186 4 .014 0.168 4188 6 .014 0.202 4190 8 .014 0.220 4192 10 .014 0.260 16 AWG Solid Bare Copper, Insulation Thickness:.009" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches 4234 2 .014 .166 4236 4 .014 .194 14 AWG Solid Bare Copper, Insulation Thickness: .013" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches 4Q) (p_i 4241 4 .014 .245 CHARACTERISTICS: Operating Temperature: -10°C to +80°C Voltage Rating: 300 Volts Color Description: Chart F, Page 42. Jacket Color: Red Product Description: Solid bare copper Insulation: Semi-Rigid PVC Nylon rip cord for ease of jacket stripping Jacket: Flame Retardant PVC Specifications: UL Type FPLRJCMRJCL3R C(UL) CMG (14 and 12 AWG FPLRJCL3R only) Passes UL 1666 Riser Flame Test RoHS Compliant C US I. LISTED 12 AWG Solid Bare Copper, Insulation Thickness: .011" Part No. No. of Cond Jacket Thickness Inches Nominal Diameter Inches 4511 2 .014 .242 www.comtrancorp.com