HomeMy WebLinkAbout2827 WHIPTAIL LP; ; FPC2019-0027; PermitPER"U[T REPORT (City of Carlsbad Print Date: 10/05/2022 Job Address: 2827 WHIPTAIL LOOP, CARLSBAD, CA 92010 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2091202600 Track #: Valuation: $718,905.07 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4*: Plan Check 4*: Permit No: FPC2019-0027 Status: Closed - Finaled Applied: 02/12/2019 Issued: 02/19/2019 Finaled Close Out: 01/07/2020 Final Inspection: INSPECTOR: Fieri, Dominic Project Title: Description: CREATE -SPRINKLER ALARM MONITORING TI Applicant: FPContractor: CHULA VISTA ALARM INC CHULA VISTA ALARM INC JAMES RODRIGUEZ 6175 PROGRESSIVE AVE, 4* STE 400 1105 CLOUDWALK CANYON DR SAN DIEGO, CA 92154-6647-SAN DIEGO CHULA VISTA, CA 91911-6835 (619) 585-9111 (619) 585-9111 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE ALARM SYSTEM SUBMITTAL CREATE 2827 WHIPTAIL LOOP W. CALSBAD, CA 92010 FPC20I9-0027 2827 WHIPTAIL LOOP CREATE - SPRINKLER ALARM MONITORING TI 2091202600 2/12/2019 F PC2OI 9-0027 FUEGO ENGINEERING & DESIGN INC P.O. BOX 212731 CHULA VISTA CA, 91921 CELL: (619) 610-8637 OFFICE: (619)796-3360 PREPARED FOR: CHULA VISTA ALARM INC 6175 PROGRESSIVE AVE. SUITE 400 SAN DIEGO, CA 92154 PHONE: 619-585-9111 n PROJECT: CREATE 2827 WHIPTAIL LOOP W. CALSBAD, CA 92010 Model Number Description CSFM# MS-9050UD FIRE-LITE FIRE CONTROL PANEL (EXISTING) 7165-0075:0210 FCPS-24FS6 FIRE LITE NAC BOOSTER POWER SUPPLY 7135-0075:0206 ANN-80 FIRE-LITE FIREALARM ANNUNCIATOR 7120-0075:0211 BG-12LX FIRE LITE ADDRESSABLE PULLSTATION 7150-0075:0184 MMF-301 FIRE LITE ADRESSABLE MINI- MONITOR MODULE 7300-0075:0185 MDF-300 FIRE LITE ADDRESSABLE DUAL MONITOR MODULE 7300-0075:0185 CRF-300 FIRE LITE ADDRESSABLE RELAY MODULE 7300-0075:0185 RTSI 51 KEY SYSTEM SENSOR REMOTE TEST/RESET STATION 7300-1653:0212 P2WL SYSTEM SENSOR WALL HORN-STROBE 7135-1653:0503 PC2WL SYSTEM SENSOR CEILING HORN-STROBE 7135-1653:0503 SWL SYSTEM SENSOR WALL STROBE 7125-1653:0504 PS-1270 BATTERY 12VDC, 7 AMP N/A FUEGO ENGINEERING & DESIGN INC PREPARED FOR: CHULA VISTA ALARM INC P.O. BOX 212731 6175 PROGRESSIVE AVE. SUITE 400 CHULA VISTA CA, 91921 SAN DIEGO, CA 92154 CELL: (619)610-8637 PHONE: 619-585-9111 OFFICE: (619)796-3360 S DF-52418:C • A1-20 MS9050UD(E) Flre•uTeALarms Fire Alarm Control Panel with DACT by Honeywell General The Fire'Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- sive list of powerful features, the MS-9050UD programs just like Fire-Lite's larger products, yet fits into applications previously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with WindoWSTI 95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Fire-Lite Upload/Download software kit PK-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polarity/city box transmitter. (4XTMF) New options include a UL listed printer, PRN-6F and the new IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the second- ary telephone line may be retained providing backup communi- cation over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9050UD is used in this data sheet to refer to both the MS-9050UD and the MS- 9050U0E FACPs. For MS-905OUDC, refer to DF-60445. Features Listed to UL Standard 864, 9th edition. Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. On-board DACT. Two independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits. Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Two programmable relays and one fixed trouble relay. Built-in Programmer. Telephone Line Active LEDs. EIA-232 PC interface. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. History file with 500 event capacity. Automatic detector sensitivity testing (NFPA 72 compliant). Automatic device type-code verification. Point trouble identification. Watertlow selection per module point. Alarm verification selection per detector point. Maintenance alert warns when smoke detector dust accumu- lation is excessive. One-person audible or silent walk test with walk-test log and printout. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant). Up to eight ANN-BUS annunciators. Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator. Upload/Download (local or remote) of program and data via integral DACT. SLC COMMUNICATION LOOP Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. 50 addressable device capacity (any combination of address- able detectors and modules). Compatible with Fire-Lite's addressable devices (refer to SLC Wiring Manual). NOTIFICATION APPLIANCE CIRCUITS (NACS) Two independently programmable output circuits. Circuits can be configured for the following outputs: - Style Y (Class B) - Style Z (Class A) - Door Holder Service (cannot be used for notification appliances) - Aux Power Source (cannot be used for notification appliances) Silence Inhibit and Autosilence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 A total power for NACs. NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A. DF-52418:C. 12/16/2009—Page 1 of 4 PROGRAMMING AND SOFTWARE Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 20 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLtNE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PK-CD, containing PK-Plus, sepa- rately). Upload/download system programming locally. User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Trouble (yellow) Alarm Silenced signals (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge/Step Alarm Silenced Drill (Manual Evacuate) Reset (lamp test) Product Line Information MS-905011,11)(E): Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, backbox with door, plastic bag contain- ing screws, cables, key, etc., manual. (For MS-905OUDC, refer to DF-60445.) PK-CD: Contains PK-Plus programming software for Win- dows®-based PC computer (cable not included). DP-51 050: Optional dress panel for the MS-9050UD. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB-55F for mounting. BAT Series: Batteries, see data sheet DF-52397. PRTIPK-CABLE: Cable printer/personal computer interface cable. PRN-61F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT, IPDACT-2121.113 Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- P2R Strobe P2R Strobe Multi-Modules CRF-300-6 Six-Relay Control Module CMF-300-6 Six-Circuit Supervised Control Module MMF-302-6 Six-Zone Interface Module MMF-300-tO Ten-Input Monitor Module ADDRESSABLE FIRE ALARM SG-12LX Addressable CONTROL PANEL Manual Pull Station Page 2 of 4— DF-52418:C • 12/16/2009 C Pi net Internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df-52424 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in turn, mounts to the FACP chassis. Use AC-TRMBLK when wire nuts are not allowed for AC connections to the transformer. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIA TORS ANN-80(-W): Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-110: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclo- sure. (See DF-60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-6024 1.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PC: Serial/Parallel Printer Printer Gateway module pro- vides a connection for a serial or parallel printer. (See OF- 52429.) ADDRESSABLE DEVICES All feature a polling LEO and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fast-response, low-profile heat detector that activates at 190°F188"C. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sen- sitivity test. D355PL: Innovair Flex low-flow non-relay duct-detector housing; includes 5D355. DNR: Innovair Flex low-flow non-relay duct-detector housing. (Order 5D355 separately.) DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order 5D355 separately) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC, MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302A: Similar to MMF-300A. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires reset- table 24 VDC power. Refer to the Device Compatibility Docu- ment for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0' (10.16 cm.) box, surface mount using the SMB500. BC-i 2LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: This module isolates the SLC loop from short circuit condi- tions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9050UD, see the following data sheets (document numbers): A0355 (DF-52386), BG- 12LX (DF- 52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/ CRF Series (DF-52130), CP355 (DF-52383), D350PL(A)/ D35ORPL(A) (DF-52398), H355 Series (DF-52385), 1300 (DF- 52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), 5D355/SD355T (DF- 52384). ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): 47k ohm supervises the MMF-300, MDF-300, MMF-301, and CMF- 300 module circuits. 3.9k ohm End-of-Line Resistor assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. DF-52418:C. 12/16/2009 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits ........................................ .1 Addressable device capacity..............................................50 Programmable software zones...........................................20 Annunciators ........ ................................................................. 8 Electrical Specifications AC Power: MS-9050UD 120 VAC, 60 Hz, 3.0 A. MS-9050UDE: 240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (MS-9050U0 cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides con- nections for two NACs, Style V (Class B) or. Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 A. End-of-Line Resis- tor: 4.7 kohm, ½ watt (PIN 71252 UL listed) for Style Y (Class B) NAC. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A © 30 VAC (resistive). Form-C relays, nonpower-limited, nonsupervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82° (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00' (48.26 cm.) high x 18.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C160 - 80°F. NFPA Standards The MS-9050UD(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9050UD(E) control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:210 S S Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) • MEA: 442-06-E high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. NOTE: See DF-60445 for ULC-listed model. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93%.t 2% RH (non- FireLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. U °U . _______________ No a MICNRIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— OF-52418:C ° 12/16/2009 S I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0210 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Model MS-9050UD addressable fire alarm control unit. Unit consists of one communication loop, two bell circuits, and three relay contact outputs for alarm, trouble and supervisory. Local, auxiliary, remote station, central station and proprietary (protected premise), automatic, manual, water flow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 3.0 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 07-07-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authonzed By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0075:0206 Page 1 of I CATEGORY: 7315 -- POWER UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett©Honeywell.com DESIGN: Models FCPS-24F56 and FCPS-24F58 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. NOTE: *Rev. 05-06-05JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52301:A2 • D-025 FCPS-24FS6 24 VnIL R Amn Pnwr Sunnlu (2) Flre•LITeALarms by HoneywellI tI-1.t.-1t1 S S The Fire-Lite FCPS-24FS6(C/) is a compact, cost-effec- tive, 6-amp remote power supplies with battery charger. The FCPS-24FS6(C/E) may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may stand-alone. Primary appli- cations include notification appliance (bell) circuit (NAG) expansion (to support ADA requirements and NAG synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FGPS provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either two Class B (Style Y) and Class A (Style Z, with ZNAC-4 option module) or four class B only. Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detec- tors. The FFCPS-24FS6(C/E) also contains a battery charger capable of charging up to 7.0 Amp hour batteries. FCPS- 24FS6(CIE) is ULC-listed. NOTE: Unless otherwise specified, the term FCPS-24FS6 used In this document refers to the standard FCPS-24FS6, FCPS- 24FS6C, FCPS-24FS6E Features UL-Listed Notification Appliance Circuit (NAC) synchroniza- tion using System Sensor, Wheelock, or Gentex "Com- mander2" appliances. Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAG (NAG expander mode) or jumped perma- nently "ON" (stand-alone mode). Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 module) NACs (circuits 1 & 3) 6-amp full load output, with 3 amps maximum/circuit, in NAG expander mode (UL 864). 4-amp continuous output in stand-alone mode (UL 1481). Compatible with ceded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery and NAGs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5"W x 2.75"D (cm: 38.1H x 36.83W x 6.985D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, damp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-24FS6: 120 VAC, 60 Hz, 3.2A maximum. FCPS-24FS61E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16-32 V); Per input: 1.0 mA (9 - 16V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-24F: 4.0 A maximum. Total short-term current for all outputs (NAG expander mode): - FCPS-24F: 6.0 A maximum. DF-52301:A2 • 5/17/13 - Page 1 of 4 Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum current charge: 250 mA. Maximum battery capacity: 7.0 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A. Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP noti- fication appliance circuits will activate the FCPS when reverse- polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A. Both resettable and non-reset- table power options are available. Resettable outputs are cre- ated by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances" away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. "NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 10,000 feet (3,046 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAG power which are created by the FACP. When installed at the end of a NAG wire run, the FCPS-24FS6 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAG wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24FS6 is configured (via DIP switch settings) as a "sync follower:' the FCPS's NAG outputs track the strobe synchronization pulses present at the FCPS's sync input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24F56 is configured (via DIP switch settings) as a "sync generator:' the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchro- nization pulses on the FCPS's NAG outputs. In "sync genera- tor" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24FS6 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Page 2014— DF-52301:A2 • 5/17/13 Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. in some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2424, S1287 ULC Listed: S2424 CSFM Approved: 7315-0076:176 MEA: 387-94E Ordering Information FCPS-24FS6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24FS6 is ULC-listed. FCPS-24FS6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAG option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AK (two required). PS-1270: Battery, 12-volt, 7.0 AK (two required). 90286: Optional module mounting kit, is required to install an addressable module on the power supply main circuit board. C S . NOTE: All NAC outputs can be converted to Style Z with Style Y NAG or ZNAC-4 option module. FCPS Door Holder Trouble Power Style Y NAG Style Y NAC Style Y NAG Contact Output #4 Output #3 Output #2 Output #1 Output 24 VDC Specific Application Power NAG Control Input #2 (from FACP) NAG Control Input #1 (from FACP) Sync Input AC Pow Battery Charger Simplified Block Diagram DF-52301 :P2 • 5/17/13 - Page 3 of 4 = C 0. 0 0 it 0 0. = 0 0 0 0 0. 0. 0 0. . . 0 2 it 0 - 0 0 U U = C - = C = = 8 8 ' I + + + 01 + + I e°I S 0 00 U) 0= o u=.0 =L2 ZU, N 0 0 0 z z C) U)0 UO C 14'0 0 [e __ CO 0 H I Z Z 0 + I 0 << C,,,,, zz +I U UC <<00 ZZj3 EZn a it ° a.2 E2 OT 0. 0.-U. 0 ow 0<0 R O E S 0 0 0 00= o- 0.00 0 0 000j Znn 0 0 0001 Board Layout System Sensor® and FireLite® Alarms are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. - We cannot cover all specific applications or anticipate all requirements. F11114011114 & MA1IIMC1URJl11 QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4014— OF-52301:A2 • 5/17/13 df-52417:c • B-90 ANN-80 Rfl.flhrv*r Iflfl (a FIreuTeALarms Serial Annunciator by Honeywell General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-805 may be connected to the ANN-BUS of each FACP. No programming is required, which saves time dur- ing system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4" square electrical box. Semi-flush mount to single, double, or 4" square electrical box, Use ANN-SB80KlT for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-80s can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption © 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 49°C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors In a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. o UL: S2424 FM approved CSFM: 7120-0075:211 MEA: 442-06-E The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. -- dt-52417:c•05/22/09—Page 1 0f2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (). Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge Current Draw (amps) 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. 6,000 ft. -6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 285 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power wiring are supervised and power-limited. Tel LTI1 432 ANN-BUS Device MS-9050U0 12345678 FACP Wiring to ANN-BUS Device ORDERING OPTIONS: ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. FireUte® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. - We cannot cover all specific applications or anticipate all requirements. MINEEIIIIIIII A MNUMC1lJl1111I All specifications are subject to change without notice. QUALITY SYSTEMS Made lri the U,S.A. For more information, contact Fire.Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-52417:c • 05/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 9• LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING No. 7120-0075:0211 Page 1 of CATEGORY: 7120 --ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Model ANN-80 and *ANN80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52013:C • E-100 > BG-12LX Fire LITALS Addressable Manual Pull Station by Honeywell r_5 Device S The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads tire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4° (10.16cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 ox. (272.15 9) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VOC. Maximum SLC loop current: 230 iiA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 930/6 (noncondensing) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4' (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is U usually needed for semi-flush mounting with 4' (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes It to latch in the dowrVactivated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600 Series, 1 - 99and MS-9200UDLS, 1 —50 for MS-9050U0). ArchitecturallEngineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with dearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-iD or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4' (10.16 cm) square electrical box, and shall be installed within DF-52013:C • 0W02/2009 - Page 1 of 2 the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-121X: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-110: Surface badbox; plastic. BG12TR: Optional trim ring. 11003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S711 MEA:67-02-E CSFM: 7150-0075:184 FM Approved Patented: U.S. Patent No, 0428,351; 6,380,846; 6,314,772; 6,632,108. Rre.LHe is a registered trademark of Honeywell International Inc. C2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is 8t110t1y prohibited The document Is not Intended to be used for Installation purposes. ISO 9001 We try to keep our product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IIIQMN1$MMIMCIIIYA All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. Rir more Information, contact FlreUte Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.flrellte.com Page 2012— DF-52013:C•09/02i2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev©Honeywell.com DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-12LW, BG-12WP, BG-I2LWP, BG-12L, BG-I2LX, BG-12LA, BG-12PS, BG-I2LSP, BG-12SP, BG-I2LR, BG-I2LRA, BG-12LAO, BG-I2LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-12SL, UT-PSi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-I2LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division fl df-52121:b. E-325 (a Fire LITALS Addressable Monitor Modules by Honeywell General MMF-300(A) Series, MDF-300(A) S Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. MMF-301 is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 Cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device it monitors. MMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF.300 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MIS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each mod- ule is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant initiating Device Cir- cuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in existing systems. MMF-300 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class MMF-300 (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300 OPERA TION Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Maximum operating current: 375 hA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125° (5.398 cm) deep box. MMF-301 Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. df-52121:b.11/13/O8—Page 1o14 1415 0 1IADDRESS 0 1 10 5 5 I 2 LOOP I 8 761 8 76 I TENS ONES I. - o Lu 0 -1 0 CQ The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The MMF-301 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules in exist- ing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterilow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301 OPERATION Each MMF-301 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (bC). MMF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 i.iA. Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3 (3.302 cm) high x 2.75 (6.985 cm) wide x 0.65° (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. MMF-302 Interface Module LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in Intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. MMF-302 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302 OPERATION Each MMF-302 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5 (11.43 cm) high x 4 (10.16 cm) wide x 1.25 (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125 (5.398 cm) deep box. MDF.300 Dual Monitor Module The MDF-300 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides two Class B (Style B) IDC circuits ONLY Class A (Style D) IDC circuits are NOT supported in any application. MDF-300 SPECIFICATIONS Supports compatible two-wire smoke detectors. Normal operating voltage range: 15 to 32 VDC. Supervises IDC wiring and connection of ex MaxImum current draw: 6.4 mA (LED on). source. Maximum operating current: 750 pA (LED flashing). High noise (EMF/RFI) immunity. Maximum IDC wiring resistance: 1,500 ohms. SEMS screws With clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series EOL resistance: 47K ohms. panels, 01 -98 on other compatible systems. Temperature range: 320 to 120°F (0° to 490C). LED flashes during normal operation. Humidity range: 10% to 93% (non-condensing). Page 2of4—dt-52121;b. 11/13/08 Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S3705 ("A" suffix models) FM Approved CSFM: 7300-0075-185 MEA: 72-01-E Product Line Information NOTE: "A" suffix indicates ULC Listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SM13500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. clf-52121:b. 11/13/08—Page 3ot4 FireLite® and LlteSpeed® are registered trademarks of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. In Iso9001 We try to keep our product information up-to-date and accurate. e cannot cover all specific applications or anticipate all requirements. & MNUMC1URIN All specifications are subject to change without notice. QUALITY SYSTEMS Made iri the U.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4of4—df-52121:b. 11/13/08 df-60379:A1 • E-400 CRF-300(A) Relv Module (a nreLITeALarms by Honeywell ftt3riJ General The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTM is a communication protocol developed by FireeLite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFl). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 —99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125' (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Ceded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (LIR=5ms) Coded 30 VDC 0.5 A Inductive (UR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A df-60379:A1 • 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA: 72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. LiteSpeedTM is a trademark and Fire-Lite® Alarms Is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EMINLEIIM R MANIJfAC11JlUM All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 - df-60379:A1 • 08/04/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models MDF-300, MMF-301 MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: 0 *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S ~ W TEM 5ENSOR® SMOKE Duct Smoke I 4 Detector Accessories 0 Expand the versatility of the InnovairFiex" line of duct smoke detectors with System Sensor notification and - test accessories. 4 Available Accessories Duct smoke detector accessories add functionality to the duct APA1 51 Piezo Annunciator smoke detection system by allowing quick, convenient inspections MHR Mini-Horn, Red at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. MHW Mini-Horn, White RTS 151 RTS 151 KEY RTS2 AOS RTS2-AOS The APA1 51 piezo annunciator, which replaces the APA45 1 with a new, improved look, provides an audible alarm signal, a red LED Remote Test Station to indicate alarm status, and a green LED to indicate power status. Remote Test Station with Key It is intended for use with System Sensor 4-wire conventional duct Multi-Signaling Accessory smoke detector applications without a system control panel, to comply with NFPA 90A. Add-On Strobe The MHR and Mill SpectrAlert* Advance mini-horns feature Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. RA100ZIRA100ZA Remote Annunciator Agency Listings The RTS151 and RTS1 51 KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS1 51 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFIex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. Specifications, Duct Smoke Detector Accessories fl Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49°C (32°F to 120°F) Relative Humidity 10 to 93% non-condensing WireGauge 12to18AWG Dimensions 4.6'H x 2.9W x.45- D Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 to 33 VDC (9 to 33 VDC with Sync-Circuit- Module) Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 17 mA RMS max. at 8 to 17.5 Volts FWR 29 mA RMS max. at 16 to 33 Volts DC 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 0°C to 49°C (32°F to 120°F) Humidity Range 10to93% non-condensing Nominal Sounder Frequency 3 kHz WireGauge 12to18AWG Dimensions 4.6'H x 2.9W x 0.45'D Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 12 mA Dimensions 4.6 "H x 2.8W x 1.3'D Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Test Switch 10 VA @32 VDC Reset Switch 10 VA @32 VDC Alarm Response Time 40 seconds max. Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing WireGauge 14t0 18AWG Dimensions 4.8Hx2.90Wx1.4D Power Requirements Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Alarm ResponseTime 40 seconds max. Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing WireGauge 14to18AWG Dimensions 4.6'Hx2.75Wx1.8D Voltage 20to29VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8Wx5.3Hx1.6D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. F SMOKE _N.H-- LJ RTS151 ULS4011 RTS151KEYULS2522 APA151 UL S4011 RTS2-AOS UL S2522 02 105ystemSens- 3825 Ohio Avenue. St. Charles, CL 60174 U'I'J5OR Phone: 800-S ENSOR2 . Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeyweIl.com DESIGN: Models RTSI5I, RTSI5I KEY and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not - an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division R E The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. SYSTEM SENSOR® Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features . • Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices Compatible with MDL3 sync module Listed for wall mounting only Agency Listings SIGNALING APPROVED . USTED S5512 FM approves except 7125-16530504 S4011 to, ALERT models 7135-16535503 3057363, 3057072 To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply, Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95,110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR12 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6-L x 4.7"W x 1.91"D (143 mm L x 119 mm W x 49 mm D) Compact Wail-Mount Dimensions (including lens) 5.26" Lx 3.46" W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6'L x 4.7"W x 1.25"D (143 mm Lx 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" D (133mm Lx 88mm W x 32mm D) Full Wave Rectified (RNR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. C UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiah 42 43 54 DC Input 8-17.5 Volts 15cd 30cd 16-33 Volts l5cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.1KTemporal Low 91 154 45 66 112 133 160 185 235 3,1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1KTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 9* . 10* 3.1 KHz Non-Temporal Coded Low High 77 85 83 90 83 90 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions -1.91 —3.46 —s 1.25 .I. 5.27 Compact Strobe I Horn Strobe 3.46 1.25 17 1 Compact Horn 4.70 IIiI I Horn L-Series Ordering Information Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have "ALERT' marking on cover SYSTOW 3825 Ohio Avenue • St. Charles, IL 60174 System Sensor Phone: 800-SENSOR2 • Fax: 630-377-6495 Prod of specifications subject to change without notes. thet eyeterrrse050r.00mn \ for current product information. including the latest semen of the date sheet, www.systemsensor.com hvos86503 • 03/17 The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. O SYSTEM SENsoR® Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNAUNG PROVED . LISTED $5512 FM approved except 7125-1653:0504 04011 for ALERT models 7135-1653:0503 3257383 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/18-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Clrcuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts: 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe fight shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and hohis at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/RNR Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9 diameter x 34' high (175 mm diameter x 86 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDSB6600 UL Current Draw Data . t!IU1 1u,]ZIW1II 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 DC Input 8-17.5 Volts 15cd 30cd 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low • 78 101 151 172 199 229 262 3.1K Temporal High 3.lKTemporal Low 108 79 135 101 179 150 200 171 225 196 255 229 289 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 Volts Volts Switch Position Sound Pattern d8 DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86BOO L-Series Dimensions 2.47 S 1.37 2.50 0 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes SCRL Strobe, Red PC2RL 2-Wire, Horn Strobe, Red SCWL Strobe, White PC2WL 2-Wire, Horn Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White SYSTEM ©2017 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications oubject to change without notice. Visit systemsensorcom Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product nforrnstron. nctudcrg Ore latest version of this data sheet. AVDSS680I • 03/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM ®r LISTING SERVICE 9 LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, . Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walilrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL 0 MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. . Color Lens: LENS-A2, LENS-82, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WaliTrim Rings: TR2 and TR2W Ceilinglrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data Sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated I2VDC setting: 8-17.5VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Fl- Quick disconnect tabs, 0.187" x 0.032"- Mate with AMP. INC. I'll F2 FASTON "187" series 144-4 - OR - LIIII Im LIIJi 1 6.35 F2 - Quick disconnect tabs, 0.250" x 0.032" .o.e .mo.8 - Mate with AMP. INC FASTON "250" series Physicali Dimensions ini Fill HI 11 H Rawl 4 MODEL P5-1270 Fl == L . 1: 5.95 (151) W: 2.56(65) H: 3.70 (94) HI: 3.86 (98) Tolerances are /- 0.04 in. (+1- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. pggsR/jisoNff MODEL i1FI Absorbent Glass Mat (AGM) technology for superior performance Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.0.T., I.A.T.A., F.A.A. and C.A.B. certified U.L. recognized under file number MH 20845 (.]IE- Nominal Voltage........................................................................12 volts (6 cells) Nominal Capacity 20-hr. (350mA to 10.50 volts) ........................................................7.00 AH 10-hr. (650mA to 10.50 volts) .......................................................6.50 AH 5-hr. (1.2A to 10.20 volts) ............................................................6.00 AH 1-hr. (4.5A to 9.00 volts) ..............................................................4.50 AH 15-mm. (14A to 9.00 volts) .................................................................3.50 AH Approximate Weight ...........................................................4.80 lbs. (2.18 kg) Energy Density (20-hr. rate) ................................1.49 W-h/1n3 (90.95 W-h/1) Specific Energy (20-hr. rate) ..............................17.50 W-h/lb (38.58 W-h/kg) Internal Resistance (approx.) ......................................................23 milliohms Max Discharge Current (7 Mm.) ...............................................21.0 amperes Max short-Duration Discharge Current (10 Sec.)..................70.0 amperes Shelf Life (% of nominal capacity at 68°F (20°c)) 1 Month ......................................................................................................97% 3 Months.....................................................................................................91% 6 Months ....................................................................................................83% Operating Temperature Range Charge .. ........................................................... -4°F(-20°C)to 122°F(50°C) Discharge ....................................................... -40°F(-40°C)to 140E17(60EC) Case......................................................................................................ABS Plastic Power-Sonic Chargers ................................................ PSc-12800A, 12800A-C 00 - -T ' Charging snot n000suey unles I 100%otoapacit S5ç '•"•' - - is required. 5°C 4' Ctrargrngbetore (41 - F) se is nesessar io u haprecover . - full capacity. 60 - - - - - - - ..- - Charge may id to restore full copacily. Do not lot battoneoreac 40°C - 30°C - - -1- 20°C I -(68°F)----- 40 - (104°F). _(86°F) - 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) Niel 154!1*4 1 01 IlIUIUIIP!iI mill 111111 0MIi1iliIIiii•I uiirniuui•u 0 14.0 13.0 8.0 Discharge Time vs. Discharge Current --- IIt:IUII ZEN rnuuu III I.._ I• 20 15 10 0 E I- o 2 C) Is u-I U, 30 C E 1 10 (104-F) (66°F) (32°F) - - I Ambient Temperature 20°C (68'F) TrtTE Float Charging 2.25 - 2.30 Voltage V/Cell 0 1 2 3 4 Years Life Characteristics in Cyclic Use 0 0 Discharge Depth 100% Discharge Depth 50°1 Discharge Depth 30% - Discharge Current 0.2C (Final Voltage 1.7VlCell) Charge Current 0.IC I I Ambient Temperature: 20°C to 25°C (68°F to 77°F) I I I I 200 400 600 800 1000 1200 Number of Cycles 120 100 80 U a 60 C.) C 40 C a, 20 Shelf Life & Storage Discharge Characteristics 1.2 2.4 6 12 2436481 2 4 6810 2040 mm cit h Discharge Time 2 100 I:: 40 20 Life Characteristics in Stand-By Use 0.35 0.70 1.4 3.5 7.0 14 Discharge Current (A) Cycle Applications: Limit initial current to 2.1A. Charge until battery voltage (undercharge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 70mA. Battery is fully charged under these conditions, and charger Should be disconnected or switched to "float" voltage. "Float" or "Stand-By" Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for "C-Series downloads, such as product catalogs, material safety data sheets (MSDS), ISO Switch Mode Chargers" and "Transformer Type A and F Series". Please contact our certification, etc.. Technical department for advice if you have difficulty in locating suitable models. 02011. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.