Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; AS080162; PermitCity of Carlsbad Sprinkler Permit Permit No: AS080162 5781 VAN ALLEN Job Address: WY Permit Type: SPRINK Parcel No: 2121304400 Status: ISSUED Applied 10/10/2008 Approved: 10/10/2008 Lot #: 0 Reference No.: Issued: 10/10/2008 PC #: Inspector: Project Title: INVITROGEN TI FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON POWAY CA 858-513-4949 Owner: GRIFFIN CAPITAL CARLSBAD POINTE INVESTORS L L C C/O INVITROGEN CORPORATION 1600 FARADAY AVE CARLSBAD CA Fees ($) 1 Add'I Fees ($) Total ($) Balance 130 0 130 0 ASOSot~2_ WESTERN FIRE PROTECTION, INC. LABORATORY 13630 DANIELSON STREET POWAY,CA 92064 HYDRAULIC CALCULATIONS FOR INVITROGEN CP-13D 5781 VAN ALLEN WAY CARLSBAD, CA 92008 FILE NUMBER: DATE: OCT 8, 2008 -DESIGN DATA- OCCUPANCY CLASSIFICATION: ORD. II DENSITY: .2 gpm/sq. ft. AREA OF APPLICATION: 1556 sq. ft. COVERAGE PER SPRINKLER: 130 max sq. ft. NUMBER OF SPRINKLERS CALCULATED: 19 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 627.3 gpm TOTAL WATER REQUIRED (including hose): 877.3 gpm FLOW AND PRESSURE (@ BOR) : 627.3 gpm @ 89.0 psi SPRINKLER K-FACTOR: 5.6 NAME OF CONTRACTOR: WESTERN FIRE PROTECTION DESIGN/LAYOUT BY: G. LOERA AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT CONTRACTOR CERTIFICATION NUMBER: C16-588039 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 50040828 HRS SYSTEMS, INC. TUCKER, GA 30084 TUCKER, GA 30084 I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 117.0 112.5 1185.0 114.4 877.3 105.0 Required pressure is 9.4 psi (8%) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 877.3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 627.3 GPM NODE ANALYSIS DATA DENSITY NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE AREA REQ. ACT. (FT) (PSI) (GPM) (FT-2) (GPM/FT-2) Si 13.0 K= 5.60 21.5 26.0 116.7 0.200 0.223 S2 13.0 K= 5.60 24.0 27.4 89.0 0.200 0.308 S3 13.0 K= 5.60 27.8 29.5 89.0 0.200 0.332 S4 13.0 K= 5.60 30.2 30.8 120.0 0.200 0.256 S5 13.0 K= 5.60 35.9 33.6 120.0 0.200 0.280 S6 13.0 K= 5.60 40.3 35.6 120.0 0.200 0.296 S7 13.0 K= 5.60 46.9 38.3 120.0 0.200 0.320 S8 13.0 K= 5.60 55.5 41.7 110.0 0.200 0.379 S9 13.0 K= 5.60 56.7 42.2 88.0 0.200 0.479 Sio 13.0 K= 5.60 57.2 42.4 88.0 0.200 0.481 Sib 13.0 K= 5.60 16.3 22.6 93.0 0.200 0.243 S12 13.0 K= 5.60 17.4 23.3 116.7 0.200 0.200 S13 13.0 K= 5.60 24.6 27.8 133.7 0.200 0.208 S14 13.0 K= 5.60 26.6 28.9 83.0 0.200 0.348 S15 13.0 K= 5.60 30.1 30.7 83.0 0.200 0.370 S16 13.0 K= 5.60 32.8 32.1 83.0 0.200 0.387 S17 13.0 K= 5.60 36.9 34.0 110.7 0.200 0.307 S18 13.0 K= 5.60 44.7 37.4 110.0 0.200 0.340 S19 13.0 K= 5.60 59.0 43.0 109.0 0.200 0.395 1 13.0 - - - - 23.4 --- 2 13.0 - - - - 26.1 --- 3 13.0 - - - - 30.3 --- 4 13.0 - - - - 32.8 --- 5 13.0 - - - - 39.0 --- 6 13.0 - - - - 43.8 --- 7 13.0 - - - - 50.9 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB NODE ANALYSIS DATA DENSITY NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE AREA REQ. ACT. (FT) (PSI) (GPM) (FT "2) (GPN/FT'2) 8 13.0 - - - - 60.1 --- 9 13.0 - - - - 61.5 --- 10 13.0 - - - - 62.0 --- 11 13.0 - - - - 17.8 --- 12 13.0 - - - - 18.9 --- 13 13.0 - - - - 26.8 --- 14 13.0 - - - - 28.9 --- 15 13.0 - - - - 32.7 --- 16 13.0 - - - - 35.7 --- 17 13.0 - - - - 40.1 --- 18 13.0 - - - - 48.5 --- 19 13.0 - - - - 63.9 - - - Ml 13.0 - --- 65.5 --- M2 13.0 - - - - 65.8 --- M3 13.0 - - - - 66.4 --- M4 13.0 - - - - 67.0 --- M5 13.0 - - - - 67.9 --- M6 13.0 - - - - 68.5 --- M7 13.0 - - - - 68.6 --- M8 13.0 - - - - 72.2 --- M9 29.0 - - - - 67.6 --- M10 29.0 - - - - 71.5 - - - Nil 29.0 - - - - 77.2 - - - TOR 29.0 - - - - 77.2 - - - BOR 3.0 - - - - 89.0 --- UG1 0.5 - - - - 90.2 --- UG2 -3.0 - - - - 91.8 --- UG3 -3.0 - - - - 92.2 --- BF1 3.0 - - - - 89.7 --- BF2 3.0 - - - - 101.7 --- UG4 -3.0 - - - - 104.5 - - - SOURCE -3.0 SOURCE 105.0 627.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -26.0 1.080 PL 2.50 PF 1.9 51 13.0 5.6 21.5 26.0 9.1 120 FTG ET PR 0.0 1 13.0 0.0 23.4 0.0 0.183 TL 10.57 PV Pipe: 2 -27.4 1.080 PL 2.50 PF 2.1 S2 13.0 5.6 24.0 27.4 9.6 120 FTG ET PE 0.0 2 13.0 0.0 26.1 0.0 0.202 TL 10.57 PV Pipe: 3 -29.5 1.080 PL 2.50 PF 2.5 S3 13.0 5.6 27.8 29.5 10.3 120 FTG ET PR 0.0 3 13.0 0.0 30.3 0.0 0.232 TL 10.57 PV Pipe: 4 -30.8 1.080 PL 2.50 PF 2.6 S4 13.0 5.6 30.2 30.8 10.8 120 FTG ET FE 0.0 4 13.0 0.0 32.8 0.0 0.251 TL 10.57 PV Pipe: 5 -33.6 1.080 PL 2.50 PF 3.1 S5 13.0 5.6 35.9 33.6 11.8 120 FTG ET PE 0.0 5 13.0 0.0 39.0 0.0 0.294 TL 10.57 PV Pipe: 6 -35.6 1.080 FL 2.50 PF 3.5 S6 13.0 5.6 40.3 35.6 12.5 120 FTG ET PR 0.0 6 13.0 0.0 43.8 0.0 0.327 TL 10.57 PV Pipe: 7 -38.3 1.080 PL 2.50 PF 4.0 S7 13.0 5.6 46.9 38.3 13.4 120 FTG ET PR 0.0 7 13.0 0.0 50.9 0.0 0.376 TL 10.57 PV Pipe: 8 -41.7 1.080 PL 2.50 PF 4.6 S8 13.0 5.6 55.5 41.7 14.6 120 FTG ET PE 0.0 8 13.0 0.0 60.1 0.0 0.440 TL 10.57 PV Pipe: 9 -42.2 1.080 PL 2.50 PF 4.7 S9 13.0 5.6 56.7 42.2 14.8 120 FTG ET PE 0.0 9 13.0 0.0 61.5 0.0 0.449 TL 10.57 PV Pipe: 10 -42.4 1.080 FL 2.50 PF 4.8 S1O 13.0 5.6 57.2 42.4 14.8 120 FTG ET PR 0.0 10 13.0 0.0 62.0 0.0 0.453 TL 10.57 PV Pipe: 11 -22.6 1.080 PL 2.50 PF 1.5 Sli 13.0 5.6 16.3 22.6 7.9 120 FTG ET PE 0.0 11 13.0 0.0 17.8 0.0 0.142 TL 10.57 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 12 -23.3 1.080 PL 2.50 PF 1.6 S12 13.0 5.6 17.4 23.3 8.2 120 FTG ET PE 0.0 12 13.0 0.0 18.9 0.0 0.150 TL 10.57 PV Pipe: 13 -27.8 1.080 PL 2.50 PF 2.2 S13 13.0 5.6 24.6 27.8 9.7 120 FTG ET PE 0.0 13 13.0 0.0 26.8 0.0 0.208 TL 10.57 PV Pipe: 14 -28.9 1.080 PL 2.50 PF 2.4 S14 13.0 5.6 26.6 28.9 10.1 120 FTG ET PE 0.0 14 13.0 0.0 28.9 0.0 0.222 TL 10.57 PV Pipe: 15 -30.7 1.080 PL 2.50 PF 2.6 S15 13.0 5.6 30.1 30.7 10.8 120 FTG ET PE 0.0 15 13.0 0.0 32.7 0.0 0.250 TL 10.57 PV Pipe: 16 -32.1 1.080 PL 2.50 PF 2.9 S16 13.0 5.6 32.8 32.1 11.2 120 FTG ET PE 0.0 16 13.0 0.0 35.7 0.0 0.271 TL 10.57 PV Pipe: 17 -34.0 1.080 PL 2.50 PF 3.2 S17 13.0 5.6 36.9 34.0 11.9 120 FTG ET PE 0.0 17 13.0 0.0 40.1 0.0 0.302 TL 10.57 PV Pipe: 18 -37.4 1.080 PL 2.50 PF 3.8 S18 13.0 5.6 44.7 37.4 13.1 120 FTG ET PE 0.0 18 13.0 0.0 48.5 0.0 0.360 TL 10.57 PV Pipe: 19 -43.0 1.080 PL 2.50 PF 4.9 S19 13.0 5.6 59.0 43.0 15.1 120 FTG ET PE 0.0 19 13.0 0.0 63.9 0.0 0.465 TL 10.57 PV Pipe: 20 -26.0 1.080 PL 10.00 PF 2.7 1 13.0 0.0 23.4 0.0 9.1 120 FTG 2E PE 0.0 2 13.0 0.0 26.1 0.0 0.183 TL 14.61 PV Pipe: 21 -53.4 1.080 PL 6.00 PF 4.2 2 13.0 0.0 26.1 0.0 18.7 120 FTG ---- PE 0.0 3 13.0 0.0 30.3 0.0 0.694 TL 6.00 PV Pipe: 22 -82.9 1.408 PL 6.00 PF 2.6 3 13.0 0.0 30.3 0.0 17.1 120 FTG ---- PE 0.0 4 13.0 0.0 32.8 0.0 0.431 TL 6.00 PV Pipe: 23 -113.7 1.408 PL 8.00 PF 6.2 4 13.0 0.0 32.8 0.0 23.4 120 FTG ---- PE 0.0 5 13.0 0.0 39.0 0.0 0.772 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 24 -147.2 1.639 PL 8.00 PF 4.8 5 13.0 0.0 39.0 0.0 22.4 120 FTG ---- PE 0.0 6 13.0 0.0 43.8 0.0 0.595 TL 8.00 PV Pipe: 25 -182.8 1.639 PL 8.00 PF 7.1 6 13.0 0.0 43.8 0.0 27.8 120 FTG ---- PE 0.0 7 13.0 0.0 50.9 0.0 0.888 TL 8.00 PV Pipe: 26 -221.1 1.639 PL 2.83 PF 14.6 7 13.0 0.0 50.9 0.0 33.6 120 FTG T FE 0.0 Ml 13.0 0.0 65.5 0.0 1.262 TL 11.56 PV Pipe: 27 -41.7 1.080 FL 4.83 PF 5.7 8 13.0 0.0 60.1 0.0 14.6 120 FTG ET PE 0.0 M2 13.0 0.0 65.8 0.0 0.440 TL 12.90 PV Pipe: 28 -42.2 1.080 FL 2.83 FE' 4.9 9 13.0 0.0 61.5 0.0 14.8 120 FTG ET FE 0.0 M3 13.0 0.0 66.4 0.0 0.449 TL 10.90 FV Pipe: 29 -42.4 1.080 PL 2.83 PF 4.9 10 13.0 0.0 62.0 0.0 14.8 120 FTG ET FE 0.0 M4 13.0 0.0 67.0 0.0 0.453 TL 10.90 PV Pipe: 30 -22.6 1.080 FL 8.00 PF 1.1 11 13.0 0.0 17.8 0.0 7.9 120 FTG ---- FE 0.0 12 13.0 0.0 18.9 0.0 0.142 TL 8.00 PV Pipe: 31 -45.9 1.080 FL 12.67 PF 7.9 12 13.0 0.0 18.9 0.0 16.1 120 FTG E PE 0.0 13 13.0 0.0 26.8 0.0 0.526 TL 14.97 PV Pipe: 32 -73.7 1.408 FL 6.00 FE' 2.1 13 13.0 0.0 26.8 0.0 15.2 120 FTG ---- PE 0.0 14 13.0 0.0 28.9 0.0 0.347 TL 6.00 FV Pipe: 33 -102.6 1.408 PL 6.00 PF 3.8 14 13.0 0.0 28.9 0.0 21.1 120 FTG ---- FE 0.0 15 13.0 0.0 32.7 0.0 0.639 TL 6.00 PV Pipe: 34 -133.3 1.639 PL 6.00 PF 3.0 15 13.0 0.0 32.7 0.0 20.3 120 FTG ---- FE 0.0 16 13.0 0.0 35.7 0.0 0.495 TL 6.00 PV Pipe: 35 -165.4 1.639 FL 6.00 PF 4.4 16 13.0 0.0 35.7 0.0 25.2 120 FTG ---- FE 0.0 17 13.0 0.0 40.1 0.0 0.738 TL 6.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 36 -199.5 1.639 PL 8.00 PF 8.3 17 13.0 0.0 40.1 0.0 30.3 120 FTG ---- PE 0.0 18 13.0 0.0 48.5 0.0 1.043 TL 8.00 PV Pipe: 37 -236.9 1.639 PL 4.83 PF 19.4 18 13.0 0.0 48.5 0.0 36.0 120 FTG T PE 0.0 M5 13.0 0.0 67.9 0.0 1.434 TL 13.56 PV Pipe: 38 -43.0 1.080 PL 4.17 PF 4.6 19 13.0 0.0 63.9 0.0 15.1 120 FTG T PE 0.0 M6 13.0 0.0 68.5 0.0 0.465 TL 9.93 PV Pipe: 39 -221.1 3.314 PL 7.50 PF 0.3 Ml 13.0 0.0 65.5 0.0 8.2 120 FTG ---- PE 0.0 M2 13.0 0.0 65.8 0.0 0.041 TL 7.50 PV Pipe: 40 -262.8 3.314 PL 10.58 PF 0.6 M2 13.0 0.0 65.8 0.0 9.8 120 FTG ---- PE 0.0 M3 13.0 0.0 66.4 0.0 0.056 TL 10.58 PV Pipe: 41 -305.0 3.314 PL 8.00 PF 0.6 N3 13.0 0.0 66.4 0.0 11.3 120 FTG ---- PE 0.0 M4 13.0 0.0 67.0 0.0 0.074 TL 8.00 PV Pipe: 42 -347.4 3.314 PL 10.17 PF 1.0 M4 13.0 0.0 67.0 0.0 12.9 120 FTG ---- PE 0.0 M5 13.0 0.0 67.9 0.0 0.094 TL 10.17 PV Pipe: 43 -584.3 3.314 PL 2.75 PF 0.7 MS 13.0 0.0 67.9 0.0 21.7 120 FTG ---- PE 0.0 M7 13.0 0.0 68.6 0.0 0.247 TL 2.75 PV Pipe: 44 -43.0 3.314 PL 12.50 PF 0.1 M6 13.0 0.0 68.5 0.0 1.6 120 FTG ET PE 0.0 M7 13.0 0.0 68.6 0.0 0.002 TL 44.53 PV Pipe: 45 -627.3 3.314 PL 2.50 PF 3.6 M7 13.0 0.0 68.6 0.0 23.3 120 FTG E PE 0.0 M8 13.0 0.0 72.2 0.0 0.282 TL 12.69 PV Pipe: 46 -627.3 4.310 PL 16.00 PF 2.3 M8 13.0 0.0 72.2 0.0 13.8 120 FTG B PE -6.9 M9 29.0 0.0 67.6 0.0 0.078 TL 29.94 PV Pipe: 47 -627.3 4.310 PL 7.50 PF 3.9 M9 29.0 0.0 67.6 0.0 13.8 120 FTG ET PE 0.0 M10 29.0 0.0 71.5 0.0 0.078 TL 49.31 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 48 -627.3 4.310 PL 60.00 PF 5.8 M10 29.0 0.0 71.5 0.0 13.8 120 FTG E PE 0.0 TOR 29.0 0.0 77.2 0.0 0.078 TL 73.94 PV Pipe: 49 0.0 6.357 PL 40.00 PF 0.0 Mil 29.0 0.0 77.2 0.0 0.0 120 FTG E PE 0.0 TOR 29.0 0.0 77.2 0.0 0.000 TL 57.60 PV Pipe: 50 -627.3 6.357 PL 26.00 PF 0.5 TOR 29.0 0.0 77.2 0.0 6.3 120 FTG E PE 11.3 BOR 3.0 0.0 89.0 0.0 0.012 TL 43.60 PV Pipe: 51 -627.3 8.249 PL 7.00 PF 0.1 BOR 3.0 0.0 89.0 0.0 3.8 120 FTC E PE 1.1 UG1 0.5 0.0 90.2 0.0 0.003 TL 28.14 PV Pipe: 52 -627.3 8.510 FL 9.00 PF 0.1 UG1 0.5 0.0 90.2 0.0 3.5 140 FTG E PE 1.5 UG2 -3.0 0.0 91.8 0.0 0.002 TL 41.72 PV Pipe: 53 -627.3 7.987 PL 130.00 PF 0.4 UG2 -3.0 0.0 91.8 0.0 4.0 150 FTG E PE 0.0 UG3 -3.0 0.0 92.2 0.0 0.003 TL 157.30 PV Pipe: 54 -627.3 8.510 PL 6.00 PF 0.1 UG3 -3.0 0.0 92.2 0.0 3.5 140 FTG E PE -2.6 BF1 3.0 0.0 89.7 0.0 0.002 TL 38.72 PV Pipe: 55 FIXED PRESSURE LOSS DEVICE BF2 3.0 0.0 101.7 0.0 12.0 psi, 627.3 gpm BF1 3.0 0.0 89.7 0.0 Pipe: 56 -627.3 8.510 PL 6.00 PF 0.2 BF2 3.0 0.0 101.7 0.0 3.5 140 FTG ET FE 2.6 UG4 -3.0 0.0 104.5 0.0 0.002 TL 102.35 PV Pipe: 57 -627.3 7.987 FL 136.00 PF 0.5 UG4 -3.0 0.0 104.5 0.0 4.0 150 FTG TG FE 0.0 SOURCE -3.0 SRCE 105.0 (N/A) 0.003 TL 195.15 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB NOTES (HASS) Calculations were performed by the HASS 7.9 computer program under license no. 50040828 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.106 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 36.0 ft/sec at pipe 37. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.080 2.30 5.76 2.30 5.76 6.91 1.15 11.52 11.52 5.76 1.408 3.31 6.62 2.21 7.72 6.62 1.10 11.03 11.03 6.62 1.639 4.36 8.73 2.18 9.82 6.54 1.09 10.91 10.91 8.73 3.314 10.19 21.84 7.28 23.29 14.56 1.46 18.93 18.93 21.84 4.310 13.94 27.87 8.36 30.66 16.72 2.79 27.87 27.87 27.87 6.357 17.60 37.72 11.32 40.23 12.57 3.77 35.21 35.21 37.72 7.987 18.07 35.13 13.05 45.16 12.04 4.01 31.11 31.11 35.13 8.249 21.14 41.11 15.27 52.85 14.09 4.70 36.41 36.41 41.11 8.510 24.60 47.84 17.77 61.51 16.40 5.47 42.37 42.37 47.84 Q 0 0 N 0 0 Q0 0 0 N 0 0 0 0 0 0 - 0 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB c c o o 0 N W 0 0 0 N -1 (C9Cl)a4 Cl) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 10/8/20082511 INVITROGEN CP-13D TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB WATER SUPPLY CURVE 120+ *\\\\\\\\\\\\ I \0\\\\\\\\\\ * <-112.5 psi 8 1185 gpm 110+ Flow Test Point I x 100+ 90+ P 80+ R I E S I S 70+ U I R I B I 60+ ( I P S I I 50+ 40+ 30+ 20+ LEGEND I 'V I X = Required Water Supply I 105.01 psi 8 877.3 gpm 10+ I 0 = Available Water Supply I 114.42 psi 8 877.3 gpm 'V 0++-+---+----+-----+ ------+ --------+ --------+ ---------+ -----------+ rU io Citi of Carlsbad - IT1 2F6i1 S1.pfl7iITTi Water Oparat}flfls David Newland Water Systems Operator II (760) 436-2722 NEXTEL (760) 602-4683 5950 El Camino Real FAX (760) 431-1601 Carlsbad, California 92008 dncwlcEcL carFsbad.a. us wwwcl. car15badcaus Hydrant Flow Request Form ASog o(6 2- Company Requesting Hydrant Flow rcA Ft ro 1flr32 Tc4 ar Static: /30 PSI Residual: )..2 psi Pitot: 30 psi Flow: // GPM Date: / ', j•7 • Time: 441 Tested by: X::/37)i /PA) Telephone Number 13 "f'A9 Fax Number 522 Location of Hydrants (Address or Other) i5791 VA,\J 4uN WA-I F1/Atf A')E Cross Street Thomas Brothers Map Page & Grid 1127 Cl Draw an accurate map and specify hydrant to flow (F) and hydrant to gauge o..o Western Fire Protection Inc. Invitrogen CP-130 Fitness Center Western Job # C - 2466 Materials Submittal Automatic Wet Pipe Sprinkler System Specification Section 15530 I Provide Stamps For Approval In Space Below 13630 Danielson Street 9 Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 141 Western Fire Protection, Inc. TABLE OF CONTENTS SPRINKLERS GLOBE QR. RECESSED PENDENT GL5601 GLOBE QR. UPRIGHT GL5615 GLOBE QR. RECESSED PENDENT GL5635 RELIABLE MODEL G4A QR. CONCEALED PENDENT II. PIPE & FITTINGS DYNA-FLOW SCHEDULE 7 DYNA-THREAD SCH-30 VICTAULIC FIRELOCK FITTINGS III. HANGER AND EARTHQUAKE BRACING ATTACHMENTS TOLCO FIG. 4A PIPE CLAMP FOR SWAY BRACING TOLCO FIG. 25 SURGE RESTRAINER TOLCO FIG. 65 & 66 REVERSIBLE C-TYPE BEAM CLAMPS TOLCO FIG. 69 BEAM CLAMP RETAINING STRAP TOLCO FIG. 99 & 100 ALL THREAD ROD TOLCO FIG. 78 CEILING PLATE TOLCO FIG. 200 "TRilvILiNE" ADJUSTABLE BAND HANGER TOLCO FIG. 800 ADJUSTABLE SWAY BRACE ATTACHMENT TO STEEL TOLCO FIG. 980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT TOLCO FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT VICTAULIC STYLES 920 AND 920N MECHANICAL -T WATTS SERIES 709DCDA (FOR REFERENCE ONLY) 12232 Thatcher Court • Poway, CA 92064 • Phone: (858) 513-4949 9 Fax: (858) 513-1322 QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION UPRIGHT" PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design require- ments. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. As- sembly is done in the field. QUICK RESPONSE PENDENT VERTICAL SIDEWALL Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C). ° Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). Maximum low temperature glass bulb rating is -67°F (-55°C). ° Frame - bronze 0 Deflector - brass o Screw - brass Bulb seat - copper o Spring - nickel alloy o Seal - teflon Bulb - glass with alcohol based solution, 3mm size. QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING I AVAILABLE SPRINKLER I BULB N.F.P.A. MAXIMUM CLASSIFICATION I TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY 135'F/1 55F 57°C/68°C ORANGE/RED 100°F . 38°C INTERMEDIATE 175°F/200°F 79°0193°C YELLOW/GREEN 150°F 66°C HIGH 286°F ... 141°C BLUE 225°F .107°C I I I I I I TECHNICAL DATA See reverse side for Approvals and Specifications. I 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 DECEMBER 2006 989-846-4583 • FAX 989-846-9231 A-20 BULLETIN GL5615, REV. #6 I I PRINTED U.S.A. I (m4mo a FIRE SPRINKLER CORPORATION DECEMBER 2006 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com BULLETIN GL5615, REV. #6 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL ° CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2' NPT 2 1/4' (5.7 cm) White Polyester 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 3 8.1 (116 metric) 3/4" NPT 2 7/16" (62 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 9/16'. 2 FINISHES AVAILABLE ON SPECIAL ORDER. °AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER. STYLE SIN K 135°F 155°F 175°F 200°F 286°F cULus F. M. LPC CE NYC - DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C MEAIOI-92-E GL2815 2.8 X X X X X X - - - X GL42154.2 X X X X X X - - - X UPRIGHT GL5615 ' 5.6 X X X X X X X X X X GL8115 7.8* X X X X X X X - - X GL8118 8.1 X X X x X X X X X GL2801 2.8. X X X X X X - - - X GL4201 4.2 X X X X X X - - - X PENDENT GL5601 / 5.6 X X X X X X X X x x GL8101 7.8* X X X X X X X - - X GL8106 8.1 X X X X X X X X X X VERTICAL GL5632 5.6 X X X X X X X - - - SIDEWALL GL8133 8.1 X X X X X X - - - -- dL2826 2.8 X X X X X X - - X HORIZONTAL GL4226 4.2 X X X X X X - - - X SIDEWALL § GL5626 5.6 X X X X X X X - - X GL8127 8.1 X X X X X X - - CONVENI1ONAL GL5624 5.6 X X X X X - - X X -- (OLD STYLE) GL8125 8.1 X X X X X - - X X - § HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6". t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. ORDERING INFORMATION °1/2" NPT SPECIFY GLOBE® PRODUCT WARRANTY °Quantity * Model Number • Style Orifice • Thread Sizes • Temperature Finishes desired -Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.) I I I I I Globe agrees to repair or replace any of its own manufactured products found to be defective in mate- rial or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). SURFACE SLEEVE MOUNT & SKIRT EXTENDED RECESSED I •-\ ••--- - k' L 'L_)LHi FIRE SPRINKLER CORPORATION QUICK RESPONSE A UTOMA TI C SPRINKLERS GL SERIES DRY TYPE DESCRIPTION AND OPERATION The Globe Quick Response GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Globe Quick Response GL Series Dry Type Pendent Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57C), 155°F (68°C), 175°F (79°C) 200°F (93°C), 286°F (141°C). Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). Maximum low temperature glass bulb rating is -67°F (-55°C). Frame - bronze o Deflector - brass o Screw - brass Bulb seat - brass o Spring - teflon coated nickel alloy Retainer - brass ° Pin - stainless steel o Torsion spring - stainless steel Bulb - glass with alcohol based solution, 3mm o Orifice insert - brass 3/4" NPT or 1" NPT o Outer tube - galvanized steel pipe Inner tube - stainless steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY - 135°F/155°F 57°C168°C ORANGE/RED 100'F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150'F 66°C HIGH 286 F 141 C BLUE 225'F 107°C I 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 APRIL 2007 A-55 I 989-846-4583 a FAX 989-846-9231 BULLETIN GL5635, REV.#1 1 I I I I I I QUICK RESPONSE A UTOMA TI C SPRINKLERS GL SERIES DRY TYPE SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES cULus Variable Factory Bronze 5.6 (80 metric) 3/4" or 1" NPT to 48" Satin Chrome1 Bright Chrome FM Variable to White Polyester 8.1 (116 metric) 1" NPT Black Polyester 36" Lead Coated NOTE: 'Finishes available on special order. Metric conversions are approximate. 2Lead Coated is UL approved only. cULus listed corrosion resistant: Polyester must be specified on order. APPROVALS STYLE SIN MODEL K FACTOR THREAD SIZE 135°F 57°C 155°F 68°C 200°F 93°C 286°F 141°C * FM cULus NYC-DOB MEA 10192E PENDENT GL5635 GL5636 GL8135 5.6 5.6 8.1 1" NPT 3/4" NPT 1" NPT X X X X X X X X X X X - X X X X X X - X X RECESSED PENDENT GL5635 GL5636 GL8135 5.6 5.6 8.1 1" NPT 3/4° NPT 1" NPT X X X X X X X X X X X - X X X X X X - X X NOTE: Listed for ALL hazards * Pendent style - FM Approed 155°F, 200°F, and 286°F * Recessed Pendent style - FM Approed 155°F and 200°F CROSS SECTIONS I 4## w EXTENDED PENDENT PENDENT mTTi ' .1. IMPORTANT INSTALLATION DATA Globe GL Series Dry Pendent sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outertube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. For further important installation data, please refer to our Dry Sprinkler Caution Sheet. ORDERING INFORMATION SPECIFY Quantity • Model Number • Style • Orifice Temperature • Finishes desired ° Quantity - Wrenches - P/N 333010 Quantity - Recessed Wrenches - P/N 337014 Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) ° Escutcheons desired "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used. r I NaZI-10110, 71111 RECESSED PENDENT OLQ0 FIRE SPRINKLER CORPORATION APRIL 2007 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workman- ship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.Com PRINTEDU.S.A. BULLETIN GL5635, REV. #11 L_-.. ,/, *,.__.. SLEEVE & SKIRT PENDENT Bulletin 154 Rev.F Model G4A Quick Response ReIiabI Concealed Automatic Sprinkler The Concealer® UL. Quick Response FM Standard Response Concealed Sprinkler With a ½" (13mm) or 11/2" (38mm) Adjustment Features Cover plate attachment with )4" (13mm) assembly adjustment. Smooth aesthetic ceiling profile. Factory installed protective cap. Available in brass, chrome or black plated and white painted finishes. Ordinary temperature rating. Multiple orifices for design flexibility. Approvals & Listings Underwriters Labortories, Inc. (UL)- Quick Response Underwriters Laboratories of Canada (ULC}- Quick Response Factory Mutual Research Corp. (FM)- Standard Response Light Hazard Occupanicies- No Limitations Ordinary Hazard Occupancies Groups 1 & 2 Wet Systems Only 4. NYC MEA 258-93-F - Quick Response U.S. Patent number 4,880,063. Application The Reliable Model G4A Concealer® is the most versatile quick response concealed sprin- kler available. It provides the best form of fire protection while offering an attractive appearance and 1/2" (13mm) of cover adjust- ment for ease of installation. The small diameter cover plate as- sembly is easily attached and blends into the ceiling concealing the most dependable fire protec- tion available, an automatic sprinkler system. The Model G4A Concealer® is designed for use where aesthetic appearance is important. Offices, hospitals, motels and restaurants are but a few of the applications where it can be used. It is available in different orifice sizes allowing the designer to optimize system performance, thereby achieving a very efficient installation. The Model G4A Concealer® is a UL Listed Quick Response Concealed sprinkler intended for use in accordance with NFPA 13. FM Approves this sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2-8N. Product Description The Reliable Model G4A Concealer® uses a proven quick re-sponse fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides ½" (13mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus exposing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model G4 Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Installation Do not install the G4A Concealer® in ceilings which have positive pressure in the space above. Cut a 2/ inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model G4 Wrench. The wrench has drive tangs which insert into the cup slots. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench tangs engage the drive slots in the top of the cup (there are two sets of drive slots in the cup). The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should betaken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceiling. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re-install cap until the cover plate is installed. Maintenance The Model G4A Concealers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Technical Data Ordering Information Sprinkler Model Nominal Orifice Flat Cover Plate Assembly Finish Inlet Type Cover Plate Finishes") Standard Finishes Bronze Chrome White Paint Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome "Other finishes and colors are available on special order. Consult factory for details. Temperature Rating Classification Sprinkler Cover Max. Ambient Plate I Temp. I Ordinary 165°F/74°C I 135°F/57°c 100°F/38°C Intermediate 212'F/1 00'C 165°F/741O 150°F/66°O Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Approvals Sprinkler ldentifcation (SIN) us I Metric Non Adjustable 112"(13mm) 1/2"(15mm) 5.6 80 1/2"NPT(R½) 12,3,4 R5415 Non Adjustable 1/2"(13mm) 7/,,°(ilmm) 4.2 60 ½ -NPT (R½) 1,2,4 R5413 Non Adjustable 1/2"(13mm) <"(10mm) 2.8 40 1/2 "NPT(R1/2) 123,4 R5411 Adjustable 1112"(38mm) '/2" (15mm) 5.6 80 1 1" NPT Male or Female 1,2,4 R5418 Adjustable 11/2"(38mm) <"(11mm) 4.2 60 1 1" NPT Male or Female 1,2,4 R5413 Adjustable 11/2"(38mm) 9<"(1omm) 2.8 1 40 1 1" NPT Male or Female 12,4 R5412 Oy2E cr'a%o,, riir7 r L ----fT-FH- !T I ., 2 6 11 01 I ETL TF i -I Fig.1 - ½" NPT Non-Adjustable Inlet Fig. 2 - 1" NPT Male-Adjustable Inlet Fig. 3 - 1" NPT Female-Adjustable Inlet The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the united States, Canada and foreign countries. Manufactured by Reliable" The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 corporate Offices www.reliablesprinkter.com Internet Address ® Recycled Paper Revision lines indicate updated or new data. EG. Printed in USA 4/07 P/N 9999970150 Additional Benefits Dyna-Flow/Super Flo pipe is manufactured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. DynamFlow@ High Strength Steel Pipe The original high-strength lightwa!l sprinkler pipe with hydraulics superior to Schedule40. Dyna-Flowpipe is the "original" high-strength lightwall sprinkler pipe. Dyna-Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule-10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Product Nominal Wt/Ft Wt/Ft PCs/ Wt/Lift Wt/Lift Wt/Lift NIPS 1. D. H20 Filled Lift 21' 24' 25' X 1" 1.191 0.830 1.31 91 1586 1812 1888 *25 30.3 1.2 1.95 91 719 822 856 X 1/4" 1.536 1.059 1.87 61 1356 1550 1615 *32 39.0 1.6 2.78 61 615 703 733 X 1/2" 1.728 1.667 2.71 61 2135 2440 2542 *40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1634 1868 1946 *50 56.0 3.1 5.64 37 741 847 883 x 2W 2.703 2.564 5.10 30 1615 1846 1923 *65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1351 1544 1608 *80 84.2 5.0 10.69 19 613 700 729 4.310 4.473 10.86 19 1784 2039 2124 *90 109.5 6.7 16.16 19 809 925 963 5 allied TUBE & CONDUIT £tljtowfl,.aO,,*, t M~ 9 Listed Approved Listed Dyna-Flow/Super Flo is UL/IJLC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna-Flow/Super Flo is now available "hot-dip"galvanized and has been specifically approved by FM for dry systems uses. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No special process or equipment are needed for fabrication and installation. 16100 S. Lathrop 11350 Norcom Rd. 2525 N. 27th Ave. Customer Service: Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 1-800-882-5543 Fax 708-339-1806 S2-4 e 1 't J. H 0. .. - American Thbe and Pipe was acquired by Allied Thbe and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyisa Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is manufactured with Black lacquer coating. Listed M Listed Submittal Data Sheet DynaFow8 I High Strength Steel Pipe Dyoa-Flowpipe is the original" high-strength lightwall sprinkler pipe. Dyna-Flow has I outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-ID pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. Stamp Here Additional Benefits Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. Superior Hydraulics With an inside diameter of up to 11% larger than Schedule 40 and up to 7% larger than Schedule 10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job Cost savings. For complete Hazen-Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Coatings & Fabrication Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No special process or equipment are needed for fabrication and installation. Specifications & Approvals Dyna-Flow/Super 40 pipe is manufactured to meet ASTM A 795 Type E, Grade A and are in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow are UL Listed, FM Approved and TJLC Listed. Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, pre-action and deluge systems. It is FM Approved for roll grooved, plain-ended, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna-Flow/Super Flo is now available "hot-dip"galvanized and has been specifically approved by FM for dry systems uses. Product Nominal Wt/Ft Wt/Ft PCs/ Wt/Lift Wt/Lift Wt/Lift NPS I.D. H20 Filled Lift 21' 24' 25' X 1" 1.191 0.830 1.31 91 1586 1812 1888 *25 30.3 1.2 1.95 91 719 822 856 .1.536 1.059 1.87 61 1356 1550 1615 *32 39.0 1.6 2.78 61 615 703 733 X1/2" 1.728 1.667 2.71 61 2135 2440 2542 40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1634 1868 1946 *50 56.0 3.1 5.64 37 741 847 883 x 21/2 2.703 2.564 5.10 30 1615 1846 1923 *65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1351 1544 1608 *80 84.2 5.0 10.69 19 613 700 729 4.310 4.473 10.86 19 1784 2039 2124 *90 109.5 6.7 16.16 19 809 925 963 I I I Project: sprInKler Uontractor Date: I Engineer: Specification Reference: System Type: Locations; Comments; S2-5 I EO DynanThreade Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch-40 with superior hydraulics and greater value. Dyrta-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyita-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable.mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a l.JL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch40 is specified. Listed Approved Listed Product Nominal Wt/Ft Wt/Ft PCs/ Wt/Lift Wt/Lift Wt/Lift NIPS I.D. H20Filled Lift 21' 24' 25' X 1" 1.080 1.330 1.75 70 1955 2234 2327 *25 27.4 2.0 2.60 70 887 1013 1056 X 1/4" 1.408 1.870 2.54 51 2002 2288 2384 *32 35.8 2.8 3.78 51 908 1038 1081 X 1½" 1.639 2.290 3.22 44 2115 2418 2519 *40 41.6 3.4 4.79 44 959 1097 1143 X 2" 2.104 *50 53.4 3.050 4.57 30 4.5 6.80 30 $ allied TUBE & CONDUIT 16100 S. Lathrop Harvey, IL 60426 1921 2196 2287 871 996 1037 Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-1 3. All sizes of Super 40/ Dyna-Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna- Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). 11350 Norcom Rd. 2525 N. 27th Ave. Customer Service: Philadelphia, PA 19154 Phoenix, AZ 85009 1-800-882-5543 Fax 708-339-1806 S3-4 Submittal Data Sheet DynaThread Stamp Here Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Alto, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, IJLC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased Strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. 0.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc-coated lightwall threadable pipe products. Dyia-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Product Nominal Wt/Ft Wt/Ft PCs/ Wt/lJft Wt/Lift Wt/Lift NPS I.D. H20 Filled Lift 21' 24' 25' X 1" 1.080 1.330 1.75 70 1955 2234 2327 *25 27.4 2.0 2.60 70 887 1013 1056 X11/4" 1.408 1.870 2.54 51 2002 2288 2384 *32 35.8 2.8 3.78 51 908 1038 1081 * 11/2" 1.639 2.290 3.22 44 2115 2418 2519 *40 41.6 3.4 4.79 44 959 1097 1143 * 2" 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwaU and standard wall family of products although they have different names are the same in aU respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is manufactured with Black lacquer coating. I Project: Sprinkler Contractor: Date: I I Engineer: Specification Reference: System Type: I Locations: Comments: S3-5 U I I I Specifications & Approvals Super 40/Dyna-Thread pipe is manufactured to meet: ASTMA 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40fDyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna-Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing infonnation). t M 9 Listed Approved Listed ti Li nj 1' FireLockTM products com- prise a unique system spe- cifically designed for fire protection services. Fire- Lock fittings are a CAD- developed, hydrodynamic design that has a shorter center-to-end dimension Patented than standard fittings. A noticeable bulge allows the water to make a smoother Flit turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclu- sively with Style 005 Fire- Lock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic Fire- Lock Style 005 couplings. /~ \taUIic® An 0 9001 certified company UPS CARBON FIRE* PROTECTION"~Mr- FireLockTM Fittings PRODUCT DESCRIPTION I I DIMENSIONS to El Cto" No. 001 No. 003 No. 002 No. 006 I I No. 001 I No. 003 No. 002 No. 006 930 Elbow 450 Elbow Straight Tee Cap________ SIZE Aprx. Aprx. Aprx. Thickness Aprx. Nominal C to E Weight C to E Weight C to E Weight "T" Weight Inches Inches Each Inches Each Inches Each Inches Each Actuat mm mm Lbsitrg mm Lbs/kg mm Lbs.!kg torn Lbs.Ik 11/4 - - - - - - 0.82 0.3 1½ 45 - - - - - - 0:82 0.4 2 .5 1.7 20 1.8 25 2.4 0.88 0.6 21/2 3.00 3.1 2.25 2.2 3;00 7113 3.6 0.88 1.0 76,1 mm 3.00 3.30 2.25 2.4 - - - - - - - - 3:38 20 3.1 3:8 5.3 0:88 1.2 4 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 5 4.88 12.6 3.25 8.3 4.86 15.7 1.00 4. 6 550 183 350 117 550 227 100 59 8 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 I Viclaulic® Waild Headquarters. P.O. Box 31, Easton, PA 18044-0031 • 4901 Kesslersville Rd., Easton, PA 18040 • 1-800-PICK VIC • FAX: 610/250-8817 • www.victaulic.com 1539 Re.B 7/00 tOt Registered Tradenrark or Victaulic a copyright 1999 Vic/aulic . Printed a, U.S.A. U"T FLOW DATA SIZE Nominal Inches Frictional Resistance ________________ Equivalent Feetlr i'y of Straight Pipe 90 Elbow No. 001 45 Elbow No. 003 Straight Tee No. 002 Branch Run 2 3.5 1.8 8.5 3.5 21/2 4.3 2.2 10.8 4.3 76,1 mm 4.5 2.3 11.0 4.5 3 50 2.6 13.0 5.0 4 6.8 3.4 16.0 6.8 6 10.0 5.0 25.0 10.0 J. 8 13.0 5.0 33.0 13.0 joe uuw, UdLd iisieu is oaseo upon iris pressure crop 01 ocneoure 4U pipe. MATERIAL SPECIFICATIONS Fitting: Ductile iron conform- ing to ASTM A-395, grade 65- 45-15, and ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel 0 Optional: Hot dipped galvanized I This product strait be manufactured by Victauiic company. All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 10.03 -2 I Fig. 4A - Pipe Clamp for Sway Bracing Size Range - 4 thru 8 pipe. For sizes smaller than 4 use TOLCO® Fig. 4. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) 4 thru 8. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Installation Instructions - The Fig. 4A is the braced pipe attachment component of a longitudinal, lateral or riser brace assembly. It is intended to be combined with the bracing pipe and TOLCO transitional and structural attachment component(s) to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 4A over the pipe to be braced. Attach TOLCO transitional fitting, either Fig. 980, 910 or 909, to the clamp ears. Tighten bolts and nuts; torque requirement is a minimum of 50 ft. lbs. Transitional fit- ting attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, pipe size and finish Component of State of California OSHPD Approved Seismic Restraints System 1:1 TOLCOO brand bracing components are desgined to be compatible ONLY with other Fig. 4A - Longitudinal Brace ToLco® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand brac- ing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCOI® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. I Dimensions .Weights Pipe Max. Horizontal Approx. Sizes A B C D Bolt Size Design Load Wt./i00 4 81h 9/16 33/8 31Y16 1/2 2015 221 5 I 93/4 9/16 37/a 4 /8 1/2 2015 253 6 11½ 5/8 5 5½ 1/2 2015 513 8 I 131/4 3/4 6/i 61/6 1/2 2015 601 I OFFICEANUFACTURING FACILITY • 1375 SAMPSON AVE.. CORONA, CA 92879 • PH: 951737.5509 • FAX: 951 737.0339 CUSTOMER SERVICE • 800.786.5266 www.iolco.com I Fig. 25 - Surge Restrainer US LISTED Size Range - One size fits 3/4 thru 2 pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger,size from 3/4' thru 2'. Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951 737.0330 CUSTOMER SERVICE • 800 786.5266 www.tolco.com In Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1/16 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13/16 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9116 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8 1/2 and 5/8 rod Component of State of California OSHPD Approved c..V,)us LISTED Material - Carbon Steel with hardened cup point set screw and Seismic Restraints System jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 1/4' (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bot- B tom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up - 0 or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. -:;:// C Approvals - Underwriters' Laboratories Listed in the USA (UL) and / Canada (cUL). Exceeds requirements of the National Fire Protection - L Association (NFPA), Pamphlet 13, 3/8' rod will support 1/2' thru 4" F pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional A load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain I Note - Available in Electro-Galvanized and HOG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA ff2879 • PH: 951 7375599 • FAX: 9517370330 a I CUSTOMER SERVICE • 800 7865266 www.tolco.com Fig. 69 - Beam Clamp Retaining Strap Size Range - 3/8 thru 7/8" rod by 4 thru 16" length." Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6-4.7.1. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mech- anism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, type, length "B" and rod size being used with beam clamp Note - Minimum return on Strap: 1". Dimensions Type Rod Size A Hole Size B 1 3/8 7116 1/2 9/16 Specify Specify 2 5/8 11/16 3/4 13/16 Specify Specify 3 3/8 -7/8 Specify Specify * Longer lengths are available, consult factory. Component of State of California OSHPD Approved US LISTED Seismic Restraints System C OFFICEJMANUFACTURING FACILITY • 1375 SAMPSON AVE.' CORONA, CA 92879 • PH. 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 860.786.5266 www.tolco.com I Fig. 78 - All Steel Ceiling Plate I& US LISTED Size Range - 3/8 rod Material - Carbon Steel Features - Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Additionally, (UL) has listed the Fig. 78 with fasteners as shown in the table below. Finish - Plain and Electro-Galvanized Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Patent #5,702,077 UL Listed Fastener Table Pipe Size Oty Fastener Type Material 1/2 -2 21/2 -4 1/2 -2 2 2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw 1/4 x 1½ wood screws* 1/4 x 1 tek screws Wood Wood Metal (18 gauge) 1/2 -2 1/2 -2 2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw #14 x 2 A-point-hex-washer-head sheet metal screw Wood Wood thru 5/8" gyp board * No pre-drilling Dimensions • Weights Max. Rec. Approx. Pipe Size A B C D E Load Lbs.* wt./100 1/2-2 3 21/8 11/8 5/16 3/8 150 15 5 - 6 Consult factory for data * Minimum safety factor of 5 I OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PR: 951.737.5599 • FAX: 951.7370330 CUSTOMER SERVICE • 889.786.5266 www.tolco.com I I I I I Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98 - Rod Stiffener I Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. I Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD'). For additional load, spacing and placement information relating to OSHPD proiects, please refer to the TOLCO I Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Component of State of California OSHPD Approved Seismic Restraints System Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8 thru 7/8 rod in I i "increments Material - Carbon Steel Maximum Temperature - 750°F I Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. I Order By - Figure number, rod diameter, rod length and finish Fig. 100- All Thread Rod Full Lengths Size Range - Secures 3/8° thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH : 951.737.5599 • FAX: 951.737 0330 I CUSTOMER SERVICE • 800 786 5266 www.tolco.com - 2 1/2 THRU 8 INCH PIPE B A 1/2 THRU 2 INCH PIPE Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8') in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (314' thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - MU. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200WON. Order By - Figure number and pipe size Dimensions Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm 0r10mm 31/8 25/a 400 11 3/4 3/8 8mm or 10mm 31/6 21/2 400 11 1 3/8 8mm or 10mm 3/e 25/a 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 11/2 3/8 8mm or 10mm 3/8 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 5/8 41/8 600 27 3 3/8 10mm 5/e 4 600 29 31/2 3/8 10mm 7 /8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 10½ 63/4 1250 73 8 1/2 12mm 131/a 83/4 1250 136 ur! I OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951 737 5599 • FAX: 951737.0330 CUSTOMER SERVICE • 800 786 5206 www.tolco.com C US LISTED Component of State of California OSHPD Approved Seismic Restraints System / SHOWN WITH F1& 98C 8RE'FITTING TO PIPE BRACE (ACOS BEAM) I Hg. 800 — Adjustable Sway Brace Attachment to Steel Size Range - 4" thru 18" beam width Material - Carbon Steel Function - Seismic brace attachment to steel. Features - This product's design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure connection to steel where drilling and/or welding of brace connection could present structural issues. Installation Instructions - The Fig. 800 is the structural attachment com- ponent of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe" and a TOLCO "braced pipe" attachment to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 800 on the steel beam, tighten the cone point set bolts on flange until bolt heads break off. Tighten hex head bolts into clamp body until lock washers are fully flat. Attach other TOLCO transi- tional attachment fittings, Fig. 909, 910 or 980. Transitional fitting attach- ment can pivot for adjustment to proper brace angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By Figure number, type number and size number. Dimensions • Weights Max. Design Loads/Lbs. (cULus) *Max.Design Loads/Lbs. (FM) Along Across Along Across Beam Beam Beam Beam 1265 2015 2800 2800 1265 2015 2800 2800 1265 2015 2800 2800 1265 2015 2800 2800 1265 2015 2800 2800 1265 2015 2800 2800 1265 2015 2800 2800 Dimensions Weights SliOWNWITH FiG: 980 Max. Design Loads/Lbs. (cULus) *Max. Design Loads/Lbs. (FM) BRACE FITT1f'G TO Flange Thickness Along Across Along Across PIPE BRACE Type Max. (In.) Beam Beam Beam Beam (ALONG BEAM) 1 3/4 1265 2015 2800 2800 2 11/4 1265 2015 2800 2800 * Load shown is allowable with brace installed, between 30 - 900. No reduction of load based on brace angle is required. TOLCO® brand bracing components are desgined to be compatible Q.N.LI with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such ToLco® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX- 951 737.0330 CUSTOMER SERVICE • 800.706.5260 www.toIco.com Size Fits Beam Range (In.) 1 4-6 2 6-8 3 8-10 4 10-12 5 12-14 6 14-16 7 16-18 Lateral Brace Fig. 980 — Universal Swivel Sway Brace Attachment Size Range - One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel, and all structural steel up to 1/4 thick. Material - Carbon Steel Function — Multi-functional attachment to structure or braced pipe fitting. Features - This product's design incorporates a concen- tric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation — The Fig .980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the bracing pipe" and TOLCO "braced pipe' attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note - The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000 , Fig. 2001 or Fig. 4A Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA) Finish - Plain Note - Available in Electro-Galvanized finish. Order By - Figure number and finish. PATENT #6,273,372 Dimensions 'Weights Max. Design **Max. Design A B H* Load Lbs. Load Lbs. Approx. wtjloo (cULus) (FMI 51/4 17/8 17/32 2785 2800 132 * Available with hole sizes to accommodate up to 3/4 fastener. consult factory. ** Load shown is allowable with brace installed, between 30° - 90°. No reduction of load based on brace angle is required. TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the ToLco® brand. NlBco shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • P1-I: 951.7375559 • FAX: 951.137.0330 PAM CUSTOMER SERVICE • 800.799.5266 www.tolco.com I I I I I Maximum Design Load 1" thru 4" pipe size - 2015 lbs. 6" size - 1265 lbs. FM Approved Design Loads* 1"-2½" -600 lbs. 3' - 4" - 700 lbs. Fig. 1000 - "Fast Clamp" Sway Brace Attachment Size Range - Pipe size to be braced: 1 thru 6" Schedule 10 thru 40 lPS.* Pipe size used for bracing: 1" and 11/4" Schedule 40 I PS. * Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4' (maximum horizontal design load 655 lbs.) Torque requirement 6 - 8 ft. lbs. Material - Carbon Steel Component of State of California 05f-tPD Approved Seismic Restraints System C® iS LISTED Function - For bracing pipe against sway and seismic I disturbance. The pipe attachment component of a sway brace sys- tem: Fig. 1000 is used in conjunction with a TOLCO Fig. 900 Series Fitting and joined together with bracing pipe per I NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features - Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of I bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to I assure installer and inspector necessary minimum torque has been achieved. Installation - The Fig. 1000 is the 'braced pipe" attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attach- ment component, Fig. 980, 910 or 909 to form a complete bracing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install - Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note - Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. TOLCO® brand bracing components are desgned to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed I seismic bracing assembly. DISCLAIMER - NlBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NISCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. I OFFICEANuFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH 9517375599 • FAX: 9517379333 CUSTOMER SERVICE 800.7865266 www.toko.cam No I IPSCAik 605 EEI- Styles 920 and 920N Mechanical-T® Bolted Branch Outlets PRODUCT DESCRIPTION Victaulic Mechanical-T® Outlet provides a direct branch connection at any - location a hole can be cut in V pipe. The hole is cut oversize Al to receive a "hlflnd" locating collar which secures the outlet in position perma- Styles 920 and 920N nently. A pressure responsive gasket seals on the pipe 00. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size con- nections. NOTE: Style 920 Style 920 Cross and Style 920N housings See chart on page 4 for pressure ratings. cannot be mated to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Spec- ify choice on order. Units are supplied painted with plated bolts. Galvanized housings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 PSI (3450 kPa) working pressure on steel pipe. They may also be used on high density poly- ethylene or polybutylene (HDPE) pipe. Pressure rat- ings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechani- cal-T Styles 920 and 920N must be installed so that the main and branch connec- tions are a true 90° angle when permanently attached to the pipeline surface. LL_:JJLL ; MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-395, grade 65-45-15, and ASTM A- 536, grade 65-45-12, with orange enamel coating. 0 Optional: Hot dipped galva- nized Gasket: (Specify choice*) 0 Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F (-34°C to +110°C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemi- cal services. UI. Classified in accordance with ANSIINSF 61 for cold +86°F (+30°C) and hot +180°F (+82°C) NOT RECOMMENDED FOR PETROLEUM SERVICES. 0 Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F (-29°C to +82°C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified tempera- tare range. Not recom- mended for hot water services over +150°F (+66°C) or for hot dry all over +140°F (+60°C). *Services listed are General Ser- vice Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Refer- ence should always be made to the latest Victaulic Gasket Selection Guide for specific gas- ket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: (Styles 920 and 920N) Heat treated carbon steel zinc plated to ASTM B-633, track-head conforming to physi- cal properties of ASTM A-I 83 minimum tensile 110,000 PSI (758340 kPa). Victaulic®Woild Headquarters • P.O. Box 31, Easton, PA 18044-0031 • 4901 Kesslecsviie Rd., Easton, PA 18040 • 1-800-PICK VIC • FAX: 610/253-8817 • www.victaulic.com 1480 Rev. E 11100 0 Registered Trademark 01 Viclaulic 0 Copyright 1999 V,clauic Printed in USA. ,V t Styles 920 and 920N wJFemale Threaded Outlet 102.20 Max Dimensions - lnchesh13i5z'hrrs' Aprx. SIZE Work. wgt. Each Hole Fern. Run X Branch Press. Dia. Thd. Grv. LS3 Fern. Nominal Inches Style PSI +0.13 V V No. F -0.00 T W Y Z Thd. Gn,. 2 I'S 1/2(a) 920N 500 1 00 253 1.63 4.21 2;50 3.1 - X ( 0-9 10 1.97 2.53 - 1.63 4.91 2.75 3,1 - 920N X . 500 1.50 1.81 2.53 - 1.63 4.91 275 3.0 - 920N X 11/4 (a) 500 1.75 2.04 275 3.00 1.63 4.91 3.00 3.5 3+2 920N 71 X 11/2 (a)t 500 1.75 2.03 2.75 3.12 1.63 4.91 3.25 36 3.2 920N 3" 7' 2112 X ½ (a) 1.50 2.21 2.74 - 1.82 5.14 2;75 3.0 - 920N 2- X 14(a) 500 1.50 2.18 2.74 - 1.82 5.14 2.75 3.0 - 920 X 1(a) 500 1.50 2.06 2.74 - 1.82 5.14 2.75 2.9 - 920N X 1¼ '' (a) 500 1:75 . 2.29 3.00 3.25 1.82 5.14 3.00 3.5 3.2 920N L 76 X 11/2 t (a) 500 2.00 2.27 3.00 325 1.82 5.14 3.25 3.6 3.3 920 N 31141 73 33 44 173 344 76,1 mm X ½ (a) 300 1.50 2.22 2.75 - 2.25 6.50 3.18 3.9 - Y, 44 920 713' 44431 X 14(a) 300 1.50 2.19 2.75 - 2.25 6.50 3.18 3.9 - 920 X 1(a) 300 1.50 2.07 2.75 - 2.25 6.50 3.18 3.8 - 920 '35,1 K. 73 - 57 155 81 .7 - X 11/4 (a) t 500 2.00 2.69 3.50 3.50 2.25 6.28 3.63 4.4 - X 42.2 920 :'.ii 5-2.3 c 3434 28 57 1342 42 43 - X 1½ (a) 500 2.00 2.69 3.50 - 2.25 6.38 3.63 4.4 4.4 920 - '-: tc. 28 Z's 2.2 DIMENSIONS Styles 920 & 920N Y ) Styles 920 and 920N wiGrooved Outlet 3 X ½ (a) 500 1.50 2.53 3.06 - 2.29 5.75 2.75 3.4 - 920N s..so .y' c-i 75 - 58 !4C 70 Li - X 3/4 (a) 500 1.50 2.50 3.06 - 2.29 5.75 2.75 3.4 - 1<267 920N 3443 331 64 78 X 1(a) 920N 500 1.50 2.37 3.06 - 2.29 5.75 2.75 3.3 - 33. #447 75 - 38 346 70 1,4 - X 11/4 (a) t 500 '11;73 2.54 3.25 3.56 2.29 5.75 3.00 3.8 3.7 X31,211;) 2 90N 343. 4 4,5, 45 3.3 33.2 58 145 75 131 1,4 X 11/2 (a) t 500 2.00 2.77 3.50 3.56 2.29 5.75 3.25 4.1 3.8 1<3151 920N 1 343.0 3013 72 SO 93 54 146 44 .3 1.5 X 2 (a) 500 2.50 2.74 3.50 3.56 2.29 5.75 3.88 4.9 4.6 1<3438 92 ON '14 535 73 89 20 55 1413 99 22 2,1 4 X ½(a) 500 1.50 3.03 3.56 - 2.69 6.69 2.75 3.7 - 92 N 0 .-:431'1 l 77 9) 58 1?ri 72 14 X 3/4(a) 500 1.50 3.00 3.56 - 2.69 6.69 2.75 3.7 - 920N 3433 551 76 33' - 134 172 73. X 1(a) 500 1.50 2.88 3.56 - 2.69 6.69 2.75 3.6 - 1< 920N ScSI. "1 7) 31': 32. 13 X 1¼(a) t 500 1,75 3.07 3.78 4.00 2.69 6.69 3.00 4.0 3.6 X4 920N 74:1 "44,5 73. 92 122 33 713 75 4 3 X 11/2 (a) t 500 2.00 3.28 4.00 4.00 2.69 6.69 3.25 4.2 3.9 >1/5 31.2 920N 44-i 7341 '43 102 11)3 30 l7u 13: X 2 (a) t 500 2.50 3.24 4.00 4.00 2.69 6.69 3.88 5.0 4.6 '2<33.3 920N 4451 355 32 :32 132 348 17:) 447 X 21/2 (a) I' 500 2.75 3.06 4.00 4.00 2.69 7.25 4.63 5.8 5.0 1<73,0 920 1o2 1334 144 11'; 7,8 14 500 2.75 - - 4.00 2.69 7.25 4.63 - 6.4 X76,1 mm 920 15% 3310 - . 112 58 154 12 X 3 (a) t 500 3.50 3.50 4.50 4.13 2.69 7.25 5.25 8.4 6.4 920 ;/y) 4 243 114 1334 3.4) loS 133 214 108,0 mm X 1¼(a) 500 1.75 3.06 3.78 - 2.63 7.25 3.13 5.0 - 33 2'2 920N 7.'51 443 "'4 III , 77 X 11/2 (a) 500 2.00 3.28 4.00 - 2.63 7.25 3.38 5.0 - 920N '1I P4 '2 500 2.50 3.24 4.00 - 2.63 7.25 4.00 5.6 - 920N X 2½(a) 500 2.75 3;06 4.00 - 2.63 7.25 4 .41 5 .5 - 920 9 3.50 - - 4.00 2.63 7.25 5.00 -6.5 920 I able corrr:rrueri on paged. ee sores on paged. NOTE: Style 920 and Style 920N hous- ings cannot be mated to achieve cross Connections. These new size Style 920N NEW products require a differ- HOLE SIZE. errt hole size than the Style 920 it replaces, for proper installation. Use caution to assure the proper size hole is prepared for the specific size and style used. Failure to use the proper hole size could result in joint leakage and property damage. 11.02-2 NOTE: Style 920 and Style 920N hous- ings cannot be mated to achieve cross Connections. These new size Style 920N products require a differ- HQLE1ZE em hole size than the Style -4 920 it replaces, for proper installation. Use caution to assure the proper size hole is prepared for the specific size and style used. Failure to use the proper hole size could result in joint leakage and property damage. NOTES "Center of run to engaged pipe end, female threaded outlet only (Dimen- sions approximate). t Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. # Female threaded outlets are avail- able to NPT and BSPT specifica- tions. British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. For 76,1 mm threaded outlet, specify 2W BSPT clearly on order. T IR Styles 920 and 920N w/Fernale Threaded Outlet Dimensions - Inches!? Aprx. SIZE Work. Hole - - Wgt. Each Run 3€ Branch Press. Dia. Thd. Grv. Lbs.f Nominal Inches Style PSI +0.13 V V Fern. No. . 0.00 T" s # t W Y Z Thd. 1GflI. 5 3< 1112(a)f 920 500 2.00 4.06 4.75 4.75 3.25 8.38 3.75 7.4 7.6 X 2 (a) t 920 500 2.50 4.06 4.75 4.75 3.25 8;38 4.38 8.2 8.0 3< 2½(a) 920 500 275 381 475 475 325 838 463 83 79 X 76,1 mm(a)(b) 920 500 . 2.75 3.81 . 4.75 .. - .. 325 8.,38 5..38, - - - - 3< 920 500 3.50 4.00 5.00 4.63 3.25 8.38 5.38 8.4 8 139,7 mm X 1½t 920 500 2.00 4.06 4.75 - 3.25 8.38 3.75 7.4 - . 920 500 2.50 4.06 4.75 - 3:5 38 4.38 8 - X 76,1 mm (a)(b) 920 500 3.50 ., - - - -. 4.63 33€ 3.25 8.38 .'- 5.38 '2- - - 8.8 x 3 920 500 3.50 - - 4.63 3.25 8.38 5.38 - 88 €.s 6 x 1/ 500 115 - - 5.13 3.79 9.13 3.25 - 4.8 920N )< 920N 500 ,2.00 5.3 3.79 X 2 (a)t 920N 500 2.50 4.37 5.13 5.13 3.79 9.13 3.88 6.0 6 (17. 357 42 2? 2.2 X 2½(a) t 920 500 2.75 4.19 5.13 5.13 3.69 9.38 4.63 8.3 7.6 23k' 8 3 34 X 76,1mm(a)(b) 920 500 .. 2.75 - - - 5.21 3.69 9.38 5.38 - 8.4 - 132 42 233137 - 3.8 X 3 (a) t 920 500 3.50 4.50 5.50 5.13 3.69 9.38 5.38 9.9 8.4 .' 232 ii4 43' t30 24 238 .2- 4.5 9.8 X 4_(a) t 920 500 4.50 4.50 5.75 5.38 3.69 9.38 6.25 10.1 10.1 ((.3 14 143 €57 34 233 152 ,€. 46 159,0 mm X 1½(a) 920N 500 2.00 4.41 5.13 - 3.63 9.25 3.38 7.8 - X 45 3 345 t2 22 -- 62 235 23' X 2 (a) 920N 500 2.50 4.37 5.13 - 3.63 9.25 4.00 8.0 - 32 55 39 - 92 235 €52 3.3 X 21/2 (a) Y.920 500 2.75 4.56 5.50 - 3.63 9.25 4.75 8.6 - 7 43 -. 22 275 €5' X 41/4 920 500 4.50 - - 5.38 3.63 9.25 6.25 - 10.0 3< 22.0 2 - 27 22 23- 165,1 mm X 1½(a)1' 920 500 ?.00 4.44 3.69 9.38 3.75 7.9 6.9- x S.'S 34-2 13 34 315 55 25 X 2(a) t 920 500 2.50 4.44 5.1 3.63 9.38 4.38 8.0 7.0 3< 512 3471 123 5.1f35 (3 §2 233 3.6 232 X 2½t 920 500 2.75 4.19 5.1 3.69 9.38 4.63 8.6 7.6 36,3 (33 X 76,lmm(a)(b) 920 500 2.75 4.08 5.1 3.69 9.38 5.38 8.6 7.6 (?. X 3 (a) l' 92 0 500 3.50 4.50 5.50 5.13 3.69 9.38 5.38 10.2 8.4 14 €53' 152 §4 333 757 43 35 X 4 (a) t 500 4.50 4.50 5.75 5.38 3.63 9.38 6.25 10.5 8.4 920 920 500 2.75 5 6.25 - 4.88 12.00 4.50 11.6 - X 21/2 (a) t 500 2.75 5.19 920 6.25 6.25 4.88 12.25 4.50 11.6 11.6 X76,lmm(a)(b) 920 500 2.75 5.19 6.25 - 4.88 12.00 5.38 - - 124 -- - - X 3(a)' 1 920 500 3.50 5.50 6.50 6.25 4.88 12.00 5.38 12 11.6 754 "435 (75 X 4(a) 920 500 4.50 5.31 6.75 6.38 4.88 12.00 6.25 12.5 DIMENSIONS Styles 920 & 920N Y--:9 Z Styles 920 and 920N w/Grooved Outlet 11.02-3 FLOW DATA Flow test data has shown that the total head loss between point fi) and () for the Style 920, 900N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below- RUN SIZE Rated Working Pressures Nominal Inches Pipe UL ULC FM Actual mrs Schedule 21/2-6 400 400 400 10,40 21/2-4 300 300 300 DF ___________ ___________ SF 30 39 APPROVED PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings! Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on 11 57-3A OUTLET SIZE Nominal Inches Equivalent Length FeetEnow of Pipe Grooved Female Threaded - 2.0 3/4 -4.0 1 - 5.0 6.0 1½ 7.0 8.0 2 9.0 10.5 21/2 11.0 12.5 3 13.5 15.5 20.0 22.0 C. Values Values for flow of water at +60°F (+16°C) are shown in the table at right. Formulas for C Values: Q2 cv2 Q = Cy'xJ Where: o = Flow (GPM) AP = Pressure Drop (PSI) Ci,, = Flow Coefficient SIZE SIZE SIZE Nominal Inches C, Nominal Inches C, Nominal Inches Actual mm Values Actual rrrtn Values Actual mm Values 1/2 211, 17 1:' 45 135 3/4 1½ 3 2EP 21 80 yeg 200 1 25 2 100 4 14.3 400 other pipe and the latest NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. listings and approvals. OF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with Current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications. designs and standard equipment without notice and without incurring obligations. 11.02-4 ç . - ... 7O9DCDAOSY Check ,A Moi ;t Cock Cover. Seat Disc Check Assembly Module Features a modular design concept which facilitates complete maintenance and assembly by retaining the spring load. First and second check valve spring modules are not inter- changeable. NowAvãilable - WattsBox Insulated Enclosures. For more nforrhtibn,.endfor literatureES-WB IMPORTANT. INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS I U Job Name Job Location I Engineer - Approval - Series 709DCDA Double Check Detector Assemblies Sizes: 3' - 10" (80 - 250mm) Series 709DCDA Double Check Detector Assemblies are designed exclusively for use in accordance with water authori- ty containment requirements. It is mandatory to prevent the reverse flow of fire protection system substances, i.e. glycerin wetting agents, stagnant water and water of non-potable qual- ity from being pumped or siphoned into the potable water line. Benefits: Detects leaks . . with emphasis on the cost of unac- countable water; incorporates a meter which allows the water utility to: detect leaks underground that historically create great annual cost due to waste. provide a detection point for unauthorized use. It can help locate illegal taps. Modular check design concept facilitates maintenance and assembly access. All sizes are standardly equipped with resilient seated OSY shutoff valves; 5/a" x 3/4' (16 x 19mm) meter and ball type test cocks. Features Body construction fused epoxy coated cast iron Replaceable bronze seats Maximum flow at low pressure drop Compact for economy combined with performance Design simplicity for easy maintenance Furnished with s/a" x 3/4" (16 x 19mm) bronze meter No special tools required for servicing Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a potable water sup- ply. Degree of hazard present is determined by the local authority having jurisdiction. The unit shall be a complete assembly including UL listed resilient seated OSY shutoff valves and test cocks. The unit shall be UL/FM approved with UL/FM approved OSY shutoff valves. The auxiliary line shall consist of an approved backflow preventer and water meter. The assembly shall meet the basic requirements of ASSE 1048; AWVVA Std. C51 0 for Double Check Valves. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be a Watts Regulator Company Series 709DCDA. Contractor Approval Contractors P.O. No Representative - WWA1TS© W REGULATOR Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, I please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Materials Body: Epoxy coated cast iron Seat: Bronze Disc Holder: Bronze Trim: Stainless steel Check Valve Discs: Rubber Test Cocks: Bronze Models Suffix: OSY - UL/FM outside stem and yoke resilient seated gate valves CFM - cubic feet per minute meter GPM - gallons per minute meter LF - 4" - 10" (100 - 250mm) without shutoff valves Pressure - Temperature Temperature Range: 33F - 1107 (5 - 43CC) continuous, 140F (60'C) intermittent Maximum Working Pressure: 175psi (12.06 bar) Standards AW/JA Standard C510 Approvals c us., S 0 Approved 8.64 1048 Approved by the foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Sizes 4" - 10" (100 - 250mm) approved for horizontal and vertical "flow up". Size 3" (76mm) approved for horizontal only. Factory Mutual approved 4" - 10" vertical "flow up". Dimensions - Weights -----------A -------------------------------------------------'I A in. mm C in. mm D in. nm E in. mm 7WM0SYtgates In. DIM SION L in. mm R in. mm T in. mm in. Lr mm WEIGHT kgs. mm 3 80 40 1016 187,/B 479 3½ 89 12 305 24 610 14 356 3 76 14 356 190 86 4 100 52 1321 22/4 578 33/4 95 17 432 34 864 15 381 6 152 14 356 403 183 6 150 621/2 1588 30¼ 765 41/2 114 21 533 411/2 1054 16 406 7½ 191 16 406 727 330 8 200 75 1905 373/4 959 5½ 140 26 660 1 52 1321 17 432 9 229. 21 533 1327 602 10 250 90 2286 1 453/4 1162 6½ 165 32 813 j 64 1626 18 457 101/4 260 25 635 2093 949 * Service clearance for check assembly from center. tULJFM approved backtlow preventers must include UL'FM approved OSY. Capacity *Typical maximum system flow rate (7.5 ft/Sec.) **UL rated flow 3' (80mm) kPa i e ps 0 66 10 2 41 U, 6H 2 O. 14 2 I 00 I 0 100 200 300 400 9pM 0 390 760 1140 1520 1pm 5 7.5 15 ps 1.5 2.3 46 mps Flow 4" (100mm) kPapsi * ** 2 96 a, 69 41 U, 2 O 14 0 100 200 300 400 500 600 gpm 0 380 160 1340 1520 1900 2285 1pm 5 75 . 15 Ips 1.5 2.3 4.6 mps Flow 6' (150mm) Va psi * ** 2 96 14 as 69 ON U, 41 a, 14 0 203 400 600 800 1000 1200 1405 gpm 760 1520 2280 3040 3803 4500 5320 1pm 5 7.5 15 fps 1.5 2.3 4.6 mps Flow 8' (200mm) Isp, psi * ** ft 96 14 69 10 U, 41 6 U, 14 2 0 DI I 0 400 800 1200 1600 2000 4000. pm 5 1520 3040 456 6080 7604 15200 1pm 5 75 15 p5 1.5 2.3 4.6 mps Flow 10' (250mm) kPa psi * ** 98 14 69 10 41 6 _________________________ ________________ 2 M 14 2 ____________________________ ___________________ Do ___________________ ______________ 0 400 800 1200 1600 2000 2400 2800 3205 3600 4000 gpm o 1520 3040 4560 8080 7600 9125 10,640 12,160 13,680 15200 1pm 5 7.5 05 IpS 1.5 2.3 4.6 mps Flow For Technical Assistance Call Your Authorized Watts Agent. Telephone 4 Fax 4 Heoouvxrms: Watts Regulator Company 815 Chestnut St., North Andover; MA 01845-6098 U.S.A. 978 688-1811 978 794-1848 Edwards, Platt & Deely, Inc. 271 Royal Ave., Hawthorne, NJ 07506 973 427-2898 973 427-4246 Edwards, Platt & Deely, Inc. 368 Wyandanch Ave., North Babylon, NY 11703 631253-0600 631253-0303 W. P. Haney Co., Inc. 51 Norfolk Ave., South Easton, MA 02375 508 238-2030 508 238-8353 J. B. O'Connor Company, Inc. P.O. Box 12927, Pittsburgh, PA 15241 724 745-5300 724 745-7420 RMI Glenfield Bus. Ctr., 2535 Mechanicsville Tpk., Richmond, VA 23223 804 643-7355 804 643-7380 The Joyce Agency, Inc. 8442 Alban Rd., Springfield, VA 22150 703 866-3111 703 866-2332 Vernon Bitzer Associates, Inc. 980 Thomas Drive, Warminster, PA 18974 215 443-7500 215 443-7573 WMS Sales, Inc. (Main office) 9580 County Rd., Clarence Center; NY 14032 716 741-9575 716 741-4810 Billingsley & Associates, Inc. 2728 Crestview Ave., Kenner, LA 70062-4829 504 602-8100 504 602-8106 Billingsley & Associates, Inc. 478 Cheyenne Lane, Madison, MS 39110 601 856-7565 601856-8390 Francisco J. Ortiz & Co., Inc. Charlyn Industrial Pk., Road 190 KM1 .9 - Lot #8, Carolina, Puerto Rico 00983 787 769-0085 787 750-5120 Mid-America Marketing, Inc. 203 Industrial Drive, Birmingham, AL 35211 205 879-3469 205 870-5027 Mid-America Marketing, Inc. 1364 Foster Avenue, Nashville, TN 37210 615 259-9944 615 259-5111 Mid-America Marketing, Inc. 5466 Old Hwy. 78, Memphis, TN 38118 901795-0045 901795-0394 Smith & Stevenson Co., Inc. 4935 Chastain Ave., Charlotte, NC 28217 704 525-3388 704 525-6749 Harry Warren, Inc. 1243 West Colonial Dr., Orlando, FL 32804 407 841-9237 407 841-9246 Watts Georgia 2861-B Bankers Industrial Drive, Atlanta, GA 30360 770 209-3310 770 447-4583 Aspinall Associates, Inc. 6840 Hillsdale Court, Indianapolis, IN 46250 317 849-5757 317 845-7967 Dave Watson Associates 1325 West Beecher, Adrian, MI 49221 517 263-8988 517 263-2328 Disney McLane & Associates 428 McGregor Ave., Cincinnati, OH 45206 800 542-1682 877 476-1682 BWA Company 17610 S. Waterloo Rd., Cleveland, OH 44119 216 486-1010 216 486-2860 Mid-Continent Marketing Services Ltd. 1724 Armitage Ct, Addison, IL 60101 630 953-1211 630 953-1067 Soderholm & Associates, Inc. 7150 143rd Ave. N.W., Anoka, MN 55303 763 427-9635 763 427-5665 Stickler & Associates 333 North 121 St, Milwaukee, WI 53226 414 771 -0400 414 771-3607 Hugh M. Cunningham, Inc. 13755 Benchmark, Dallas, DC 75234 972 888-3808 972 888-3838 Mack McClain & Associates 11132 South Towne Square, Suite 202, St Louis, MO 63123 314 894-8188 314 894-8388 Mack McClain & Associates, Inc. 1450 NE 69th Place, Ste. 56 Ankeny, IA 50021 515 288-0184 515 288-5049 Mack McClain & Associates, Inc. 15090 West 116th St., Olathe, KS 66062 913 339-6677 913 339-9518 01<1 Sales, Inc. 2200 Blue Creek Dr., Norman, 01< 73026 405 360-6161 405 360-0092 Phoenix Marketing, Ltd. 2416 Candelaria N.E., Albuquerque, NM 87107 505 883-7100 505 883-7101 Delco Sales, Inc. 1930 Rayrner Ave., Fullerton, CA 92833 714 888-2444 714 888-2448 Delco Sales, Inc. 111 Sand Island Access Rd., Unit 1-10, Honolulu, HI 96819 808 842-7900 808 842-9625 Fanning & Associates, Inc. 6765 Franklin St., Denver, CO 80229-7111 303 289-4191 303 286-9069 Hollabaugh Brothers & Associates 6915 South 194th St, Kent, WA 98032 253 867-5040 253 867-5055 Hollabaugh Brothers & Associates 3028 S.E. 17th Ave., Portland, OR 97202 503 238-0313 503 235-2824 P I A Sales, Inc. 3050 North San Marcos Place, Chandler; AZ 85225 480 892-6000 480 892-6096 Preferred Sales 31177 Wiegman Road, Hayward, CA 94544 510 487-9755 510 476-1595 R. E. Fitzpatrick Sales, Inc. 4109 West Nike Dr. (8250 South), West Jordan, UT 84088 801282-0700 801282-0600 Watts Industries (Canada) Inc. (Watts Regulator Co. Division) 5435 North Service Road, Burlington, Ontario L7L 5H7 905 332-4090 905 332-7068 Con-Cur West Marketing, Inc. 71 B Clipper Street, Coquitlam, British Columbia V3K 6X2 604 540-5088 604 540-5084 D.C. Sales Corporation Inc. #10-6130 4th St. S.E., Calgary, Alberta T2H 2A6 403 253-6808 403 259-8331 D.C. Sales Corporation Inc. 11420 142 Street, Edmonton, Alberta T5M lvi 780 496-9495 780 496-9621 GTA Sales Team. Greater Toronto Area 888 208-8927 888 479-2887 Hydro-Mechanical Sales, Ltd. 3700 Joseph Howe Drive, Suite 1, Halifax, Nova Scotia B3L 4H7 902 443-2274 902 443-2275 Hydro-Mechanical Sales, Ltd. P.O. Box 1445 (Mailing), 297 Collishaw St, Suite 7 (shipping) Moncton, New Brunswick El C 9R2 506 859-1107 506 859-2424 J.D.S. Sales Ltd. 4 Lancaster Street, St. John's, Newfoundland At 5P7 709 579-5771 709 579-1558 Le Groupe B.G.T., Inc. 23 du Buisson, Pont Rouge, Quebec G3H 1X9 418 873-2500 418 873-2505 Le Groupe B.G.T., Inc. 86 des Enterprises #208, Boisbriand, Quebec J7G 2T3 450 434-9010 450 434-9848 Mar-Win Agencies, Ltd. 1333 Clifton St., Winnipeg, Manitoba R3E 2V1 204 775-8194 204 786-8016 Northern Mechanical Sales P.O. Box 280 (mailing) 163 Pine St. (shipping), Garson, Ontario P3L 1S6 705 693-2715 705 693-4394 Palser Enterprises, Ltd. P.O. Box 28136 (mailing), 1885 Blue Heron Dr., #4, London, Ontario N6H 51_9 519 471-9382 519 471-1049 RAM Mechanical Marketing Inc. 1401 St. John Street, Regina, Saskatchewan S4R 1 S5 306 525-1986 306 525-0809 RAM Mechanical Marketing Inc. 510 Ave M South, Saskatoon, Saskatchewan S7M 2K9 306 244-6622 306 244-0807 Walmar Mechanical Sales 24 Gurdwara Rd., Nepean, Ontario K2E 8B5 613 225-9774 613 225-0673 EXPORT Hdqtrs.: Watts Regulator Co. 815 Chestnut St., North Andover, MA 01845-6098 USA. 978 688-1811 978 794-1848 ' WATWFMI 90011 Watts USA website: www.wattsreg.com REGULATOR I CERTIFIED I Watts Canada website: www.wattscanada.ca ES-709DCDA 0522 0 Watts Regulator Company, 2005