HomeMy WebLinkAbout369 JUNIPER AVE; ; AS140130; Permit9/14/22,10:17 AM AS140130 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS140130 Job Address: 369 JUNIPER AV Status: APPROVED Permit Type: SPRINK Applied 5/30/2014 Parcel No: 2042403400 Approved: 6/13/2014 Lot #: 0 Reference No.: Issued: 6/13/2014 PC #: Inspector: Project Title: BEACHWALK PLAN CHECK FEES ON THIS PERMIT ONLY THIS IS A WET PIPE SPRINKLER SYSTEM DESIGNED AND INSTALLED PER 313.3 AND / OR NFPA. ALL PIPE AND FITTINGS ARE NEW AND UL LISTED. PROVIDE ELECTRIC BELL FOR LOCAL ALARM. WIRING BY OTHERS, SIZE AND LOCATION ON PIPING PLANS. STORAGE IN ATTIC AND CRAWL SPACES NOT ALLOWED WHERE NOT PROTECTED. GARAGE AND MECHANICAL ROOMS TO BE SPRINKLED W/ 175HD. SPRINKLER HEADS OMITTED FROM BATHROOMS DUE TO NON COMBUSTIBLE FIXTURES AND NOT EXCEEDING 55 SF Applicant: SYMONS FIRE PROTECTION SUITE R 1050 PIONEER WAY EL CAJON, CA 619-588-6364 Owner: 369 JUNIPER ACQ L L C 3460 MARRON RD #103 OCEANSIDE CA Fees(s) Add'l Fees ($) Total ($) Balance($) 470 0 470 0 about:blank 1/2 Parsley Consulting Plan Review Comments for Beachwalk Units A-D page 2 of 2 The following comments are for your information and will appear on every residential sprinkler review. The alarm bell must be capable of being heard, above background noise, with doors closed, in all living areas of the residence. This will be checked at final acceptance. Pressure required at base of riser will be verified to be available at time of final acceptance. Sprinkler heads are omitted from bathroom areas under 55 SF in area with noncombustible plumbing fixtures. Fixtures will be verified at final acceptance. Sprinkler head blockage or pattern disruption caused by beams or other obstructions will be verified to not exist at final acceptance inspection. Sprinkler heads should be located the proper distance from heat sources (stoves, kitchen ranges, fireplaces, heat diffusers, etc.) This will be checked at final acceptance inspection. 0 Sprinkler heads located in an unconditioned space (garage, water heater closet, etc.) should be fast response type with an appropriate temperature rating, commercial heads are acceptable in these areas. g) All exposed piping shall be black steel or copper. Concealed piping can be CPVC plastic. File: i:\Plan Reviews\Rev2 14236.1 .Docx y -i rsi m mmm m 0000 >>>>I WWW LLj — — — — o'mN DbN 00 mmm m 3YMONS FIRE PROTECTION, INC. 1050 PIONEER WAY, SUITE R EL CAJON, CA 92020F The.c piari has c henri ievress cii tor toj rent cottipirarree LICENSE C16-682025 isitir tie errrrert applicable codes arid ldalds iii IOICe Ill tile limsdiction. Tire owlet or contractor airy L01111C tIns i_s CO I ll support ol nit ipphtcatrill tot It hnrinttti HYDRAULIC CAL C U LAT 10 S ri Ii ire e specs utuderst till I rt hat 1111' 10 tess FOR in to stat rehreses the st tier iii contractor or herr pirtessnuta errenreer rrr architect or sole resprrrtsrhilrtt fol null crrrirphlatlCc wilt said codes itild standarris. BEACHWALK PROJECT u_1ti_ di nihdut rids or Iii its ti_pa hilts 101 UNIT A *** plaits isltether OF liii lioled itt Illis review, lkilhc REMOTE AREA 2 HEAD CAli TYCO LF II CONC/FLA'1 it (.( )NI EN) APPROVAl. 10 RI..oiiFNt .\1lRii\'\l., AS Nor1:i) FILE NUMBER: 14-002 DATE: 5-8-14 44/c fri5 -DESIGN DATA- R3 .05 gpm/256 sq. ft. 512 sq. ft. 2 sprinklers 26.3 gpm 31.3 gpm (5 gpm Hose STREAM) 26.3 gpm @ 33.5 psi 4.9 CANDI CAUDILLO CARLSBAD FIRE DEPT. 89 psi (-10% 80 PSI) 88 psi 500 gpm CARLSBAD WATER 1-13-14 OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@ NODE 5 BOR): SPRINKLER K-FACTOR (ORIFICE SIZE) DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: WATER FLOW AVAILABILITY DATA: STATIC: RESIDUAL: FLOW: WATER DEPARTMENT: CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. ATLANTA, GA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002.SDF JOB TITLE: UNIT A - 2 HEAD CALC J. WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 80.0 79.0 500.0 80.0 31.3 60.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 60.5 31.3 2 3.0 - - - - 51.8 3 3.0 - - - - 47.8 4 5.0 - - - - 40.5 5 9.0 HOSE STREAM 33.5 5.0 6 15.0 - - - - 29.5 - - - 7 15.0 - - - - 26.9 - - - 8 25.0 - - - - 18.6 9 25.0 - - - - 20.2 10 35.0 - - - - 9.3 11 35.0 - - - - 9.4 12 35.0 K= 4.90 7.0 13.0 13 35.0 K= 4.90 7.3 13.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002.SDF JOB TITLE: UNIT A - 2 HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FP) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.3 0.995 PL 20.00 PF 7.4 1 0.0 SRCE 60.5 (N/A) 12.9 150 FTG TG PE -1.3 2 3.0 0.0 51.8 0.0 0.255 TL 29.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 3.0 0.0 51.8 0.0 4.0 psi, 31.2 gpm 3 3.0 0.0 47.8 0.0 Pipe: 3 31.2 1.101 PL 40.00 PF 6.4 3 3.0 0.0 47.8 0.0 10.5 150 FTG 1.0 PE -0.9 4 5.0 0.0 40.5 0.0 0.155 TL 41.00 PV Pipe: 4 31.2 1.025 PL 5.00 PF 5.3 4 5.0 0.0 40.5 0.0 12.1 150 FTG 19.0 PE -1.7 5 9.0 H.S. 33.5 5.0 0.220 TL 24.00 PV Pipe: 5 26.2 1.101 PL 6.00 PF 1.5 5 9.0 H.S. 33.5 5.0 8.8 150 FTG 7.0 PE -2.6 6 15.0 0.0 29.5 0.0 0.112 TL 13.00 PV Pipe: 6 8.7 0.874 PL 34.00 PF 2.6 6 15.0 0.0 29.5 0.0 4.7 150 FTG 24.0 PE 0.0 7 15.0 0.0 26.9 0.0 0.045 TL 58.00 PV Pipe: 7 8.7 0.874 PL 33.00 PF 3.9 7 15.0 0.0 26.9 0.0 4.7 150 FTG 54.0 PE -4.3 8 25.0 0.0 18.6 0.0 0.045 TL 87.00 PV Pipe: 8 17.5 0.874 PL 13.00 PF 4.9 6 15.0 0.0 29.5 0.0 9.4 150 FTG 17.0 PE -4.3 9 25.0 0.0 20.2 0.0 0.164 TL 30.00 PV Pipe: 9 -6.3 0.874 PL 36.00 PF 1.6 8 25.0 0.0 18.6 0.0 3.4 150 FTG 28.0 PE 0.0 9 25.0 0.0 20.2 0.0 0.025 TL 64.00 PV Pipe: 10 15.0 0.874 PL 18.00 PF 4.9 8 25.0 0.0 18.6 0.0 8.0 150 FTG 22.0 PE -4.3 11 35.0 0.0 9.4 0.0 0.123 TL 40.00 PV Pipe: 11 11.2 0.874 PL 38.00 PF 6.6 9 25.0 0.0 20.2 0.0 6.0 150 FTG 53.0 PE -4.3 10 35.0 0.0 9.3 0.0 0.072 TL 91.00 PV Pipe: 12 13.0 0.874 PL 9.00 PF 2.3 10 35.0 0.0 9.3 0.0 7.0 150 FTG 15.0 PE 0.0 12 35.0 4.9 7.0 13.0 0.094 TL 24.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYS I S Page 3 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\ 1 4 - 0 0 2 . S D F JOB TITLE: UNIT A - 2 HEAD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GEM) FL/FT (PSI) Pipe: 13 -1.8 0.874 FL 10.00 PF 0.1 10 35.0 0.0 9.3 0.0 0.9 150 FTG 15.0 PE 0.0 11 35.0 0.0 9.4 0.0 0.002 TL 25.00 PV Pipe: 14 13.2 0.874 FL 6.00 PP 2.1 11 35.0 0.0 9.4 0.0 7.1 150 FTG 15.0 FE 0.0 13 35.0 4.9 7.3 13.2 0.098 TL 21.00 PV NOTES (HASS) Calculations were performed by the H A S S 8 . 4 c o m p u t e r p r o g r a m under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to pr o v i d e a n a v e r a g e imbalance at each node of 0.013 gp m a n d a m a x i m u m imbalance at any node of 0.155 gp m . Total pressure at each node is use d i n b a l a n c i n g t h e s y s t e m . Maximum water velocity is 12.9 ft/ s e c a t p i p e 1 . Items listed in bold print on th e c o v e r s h e e t are automatically transferred from t h e c a l c u l a t i o n r e p o r t . Available pressure at source node 1 u n d e r f u l l f l o w c o n d i t i o n s i s 79.99 psi compared to the minimum r e q u i r e d p r e s s u r e o f 2 0 . 0 0 p s i . PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv Alm C h k D P V l v N P T e e 1.101 2.53 6.33 2.53 6.33 7.59 1 . 2 7 1 2 . 6 6 1 2 . 6 6 6 . 3 3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 'DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002.SDF JOB TITLE: UNIT A - 2 HEAD CALC PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 0.874 5.00 3.00 1.00 0.00 1.00 1.00 0.00 1.00 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 a)üj a aij )t3 C/CJO 3 a) C•) 3 U) U)- U a)CO co('aE ai a' ,C/)U a 1--f U) U)OU) aa a)a- 4 Lr) a) U, HLO 0 > (J --io CiCfl 0'• W.. H C'i -1 j) 1) D o -) I Ii -) H I) 0 0 0 H 4.) U) 0 CD C-i 0 0 44 Cl) H Cl) 0 0 N f24 a) CJ o 04 4.J 0 0 4) Cl) 0 0 -H SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002.SDF JOE TITLE: UNIT A - 2 HEAD CALC 0 0 0 0 0 0 law 0 o 0 a4 12~ (D o o• CN SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002.SDF JOE TITLE: UNIT A - 2 HEAD CALC WATER SUPPLY CURVE 84+ 0\\\\\\\\\\\\\\\\\ * <-79.0 Psi @ 500 gpm 77+ Flow Test Point 70+ 63+ x P 56+ R I E S I S 49+ U R E I 42+ P S I I 35+ 28+ 21+ 14+ LEGEND 'I X = Required Water Supply I 60.46 psi @ 31.3 gpm 7+ 0 = Available Water Supply 79.99 psi @ 31.3 gpm +------+--------+--------+ ---------+ -----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) SYMONS FIRE PROTECTION, INC. 1050 PIONEER WAY, SUITE R EL CAJON, CA 92020 LICENSE C16-682025 HYDRAULIC CALCULATIONS FOR BEACHWALK PROJECT UNIT B ** REMOTE AREA 2 HEAD CALC TYCO LF II CONC/FLAT FILE NUMBER: 14-002 DATE: 5-8-14 -DESIGN DATA- OCCUPANCY CLASSIFICATION: R3 DENSITY: .05 gpm/256 sq. ft. AREA OF APPLICATION: 512 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 26.2 gpm TOTAL WATER REQUIRED (including hose): 31.2 gpm (5 gpm Hose STREAM) FLOW AND PRESSURE (@ NODE 5 BOR): 26.2 gpm @ 33.9 psi SPRINKLER K-FACTOR (ORIFICE SIZE): 4.9 DESIGN/LAYOUT BY: CANDI CAUDILLO AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT. WATER FLOW AVAILABILITY DATA: STATIC: 89 psi (-10% 80 PSI) RESIDUAL: 88 psi FLOW: 500 gpm WATER DEPARTMENT: CARLSBAD WATER 1-13-14 CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. ATLANTA, GA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-1.SDF JOB TITLE: UNIT B - 2 HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQTD NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 80.0 79.0 500.0 80.0 31.2 63.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 63.8 31.2 2 3.0 - - - - 55.2 - - - 3 3.0 - - - - 51.2 4 5.0 - - - - 40.9 - - - 5 9.0 HOSE STREAM 33.9 5.0 6 15.0 - - - - 29.9 - - - 7 15.0 - - - - 26.9 - - - 8 25.0 - - - - 18.0 9 25.0 - - - - 18.7 - - - 10 35.0 - - - - 9.4 - - - 11 35.0 - - - - 9.4 - - - 12 35.0 K= 4.90 7.2 13.1 13 35.0 K= 4.90 7.0 13.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-1.SDF JOB TITLE: UNIT B - 2 HEAD CALC PIPE DATA PIPE TAG. Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.2 0.995 FL 20.00 PF 7.3 1 0.0 SRCE 63.8 (N/A) 12.9 150 FTG TG PE -1.3 2 3.0 0.0 55.2 0.0 0.253 TL 29.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 3.0 .0.0 55.2 0.0 4.0 psi, 31.1 gpm 3 3.0 0.0 51.2 0.0 Pipe: 3 31.1 1.101 FL 60.00 PF 9.4 3 3.0 0.0 51.2 0.0 10.5 150 FTG 1.0 PE -0.9 4 5.0 0.0 40.9 0.0 0.154 TL 61.00 PV Pipe: 4 31.1 1.025 PL 5.00 PF 5.2 4 5.0 0.0 40.9 0.0 12.1 150 FTG 19.0 FE -1.7 5 9.0 H.S. 33.9 5.0 0.218 TL 24.00 PV Pipe: 5 26.1 1.101 FL 6.00 PF 1.5 5 9.0 H.S. 33.9 5.0 8.8 150 FTG 7.0 FE -2.6 6 15.0 0.0 29.9 0.0 0.112 TL 13.00 PV Pipe: 6 8.7 0.874 FL 33.00 PF 2.9 6 15.0 0.0 29.9 0.0 4.6 150 FTG 32.0 FE 0.0 7 15.0 0.0 26.9 0.0 0.045 TL 65.00 PV Pipe: 7 8.7 0.874 FL 51.00 PF 4.6 7 15.0 0.0 26.9 0.0 4.6 150 FTG 51.0 PE -4.3 8 25.0 0.0 18.0 0.0 0.045 TL 102.00 PV Pipe: 8 17.4 0.874 FL 20.00 PF 6.8 6 15.0 0.0 29.9 0.0 9.3 150 FTG 22.0 FE -4.3 9 25.0 0.0 18.7 0.0 0.163 TL 42.00 PV Pipe: 9 -4.8 0.874 FL 22.00 PF 0.6 8 25.0 0.0 18.0 0.0 2.5 150 FTG 22.0 FE 0.0 9 25.0 0.0 18.7 0.0 0.015 TL 44.00 PV Pipe: 10 13.4 0.874 PL 16.00 PF 4.3 8 25.0 0.0 18.0 0.0 7.2 150 FTG 27.0 FE -4.3 10 35.0 0.0 9.4 0.0 0.100 TL 43.00 PV Pipe: 11 12.7 0.874 FL 23.00 PF 5.0 9 25.0 0.0 18.7 0.0 6.8 150 FTG 32.0 FE -4.3 11 35.0 0.0 9.4 0.0 0.090 TL 55.00 PV Pipe: 12 0.4 0.874 FL 12.00 PF 0.0 10 35.0 0.0 9.4 0.0 0.2 150 FTG 18.0 FE 0.0 11 35.0 0.0 9.4 0.0 0.000 TL 30.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 'DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-1.SDF JOB TITLE: UNIT B - 2 HEAD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 13.0 0.874 PL 9.00 PF 2.4 10 35.0 0.0 9.4 0.0 7.0 150 FTG 16.0 PE 0.0 13 35.0 4.9 7.0 13.0 0.094 TL 25.00 PV Pipe: 14 13.1 0.874 PL 8.00 PF 2.2 11 35.0 0.0 9.4 0.0 7.0 150 FTG 15.0 PE 0.0 12 35.0 4.9 7.2 13.1 0.096 TL 23.00 PV NOTES (HASS) Calculations were performed by the HASS 8.4 comp u t e r p r o g r a m under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an av e r a g e imbalance at each node of 0.010 gpm and a maximum imbalance at any node of 0.116 gpm. Total pressure at each node is used in balancin g t h e s y s t e m . Maximum water velocity is 12.9 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calcula t i o n r e p o r t . Available pressure at source node 1 under full fl o w c o n d i t i o n s i s 79.99 psi compared to the minimum required pres s u r e o f 2 0 . 0 0 p s i . PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEil ChkViv BfyVlv GatViv AimChk DPViv N P T e e 1.101 2.53 6.33 2.53 6.33 7.59 1.27 12.66 1 2 . 6 6 6 . 3 3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-1.SDF JOB TITLE: UNIT B - 2 HEAD CALC PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 0.874 5.00 3.00 1.00 0.00 1.00 1.00 0.00 1.00 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 E 04 a! G)O OUO o o U) U) r-1 U)- o 04 In r:l a Cl-H HCl -- o -1 CO -Q 04 t) (0 0 0) aa- L.r1 (0 0 co -HOO>, (L -,-a U) (f) CQ '- (N o H (F) U) H I U) J co C-) H F-) (U I-) 1) 0 0 0 H H (I) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 'DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-1.SDF JOB TITLE: UNIT B - 2 HEAD CALC 0 0 0 0 0 0 0 0 0 0 co a)' H SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-1.SDF JOB TITLE: UNIT B - 2 HEAD CALC WATER SUPPLY CURVE 84+ 0\\\\\\\\\\\\\\\\\ I * <-79.0 psi @ 500 gpm 77+ Flow Test Point 70+ 63X P 56+ R I E S I S 49+ U R I E 42+ ( I P S I I 35+ 28+ 21+ 14+ LEGEND I X = Required Water Supply 63.79 psi @ 31.2 gpm 7+ 0 = Available Water Supply 79.99 psi @ 31.2 gpm 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) SYMONS FIRE PROTECTION, INC. 1050 PIONEER WAY, SUITE R EL CAJON, CA 92020 LICENSE C16-682025 HYDRAULIC CALCULATIONS FOR BEACHWALK PROJECT *** UNIT C REMOTE AREA 2 HEAD CALC TYCO LF II CONC/FLAT FILE NUMBER: 14-002 DATE: 5-8-14 -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@ NODE 5 BOR): SPRINKLER K-FACTOR (ORIFICE SIZE): DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: WATER FLOW AVAILABILITY DATA: STATIC: RESIDUAL: FLOW: WATER DEPARTMENT: R3 .05 gpm/256 sq. ft. 512 sq. ft. 2 sprinklers 26.1 gpm 31.1 gpm (5 gpm Hose STREAM) 26.1 gpm @ 33.9 psi 4.9 CANDI CAUDILLO CARLSBAD FIRE DEPT. 89 psi (-10% 80 PSI) 88 psi 500 gpm CARLSBAD WATER 1-13-14 CALCULATIONS BY HASS COMPUTER PROGRAM FIRS SYSTEMS, INC. ATLANTA, GA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 IDATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-2.SDF JOE TITLE: UNIT C - 2 HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 80.0 79.0 500.0 80.0 31.1 67.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 67.2 31.1 2 3.0 - - - - 58.6 3 3.0 - - - - 54.6 4 5.0 - - - fl 40.9 5 9.0 HOSE STREAM 33.9 5.0 6 15.0 - - - - 29.9 7 15.0 - - - - 27.0 - - - 8 25.0 - - - - 18.1 9 25.0 - - - - 18.7 10 35.0 - - - - 9.4 11 35.0 - - - - 9.4 12 35.0 K= 4.90 7.2 13.1 13 35.0 K= 4.90 7.0 13.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 IDATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-2.SDF JOB TITLE: UNIT C - 2 HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.1 0.995 PL 20.00 PF 7.3 1 0.0 SRCE 67.2 (N/A) 12.8 150 FTG TG PE -1.3 2 3.0 0.0 58.6 0.0 0.253 TL 29.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 3.0 0.0 58.6 0.0 4.0 psi, 31.1 gpm 3 3.0 0.0 54.6 0.0 Pipe: 3 31.1 1.101 PL 80.00 PF 12.8 3 3.0 0.0 54.6 0.0 10.5 150 FTG 3.0 FE -0.9 4 5.0 0.0 40.9 0.0 0.154 TL 83.00 PV Pipe: 4 31.1 1.025 FL 5.00 PF 5.2 4 5.0 0.0 40.9 0.0 12.1 150 FTG 19.0 PE -1.7 5 9.0 H.S. 33.9 5.0 0.219 TL 24.00 PV Pipe: 5 26.1 1.101 FL 6.00 PF 1.5 5 9.0 H.S. 33.9 5.0 8.8 150 FTG 7.0 PE -2.6 6 15.0 0.0 29.9 0.0 0.112 TL 13.00 PV Pipe: 6 8.7 0.874 PL 33.00 PF 2.9 6 15.0 0.0 29.9 0.0 4.6 150 FTG 32.0 PE 0.0 7 15.0 0.0 27.0 0.0 0.045 TL 65.00 PV Pipe: 7 8.7 0.874 PL 51.00 PF 4.6 7 15.0 0.0 27.0 0.0 4.6 150 FTG 51.0 PE -4.3 8 25.0 0.0 18.1 0.0 0.045 TL 102.00 PV Pipe: 8 17.4 0.874 PL 20.00 PE' 6.8 6 15.0 0.0 29.9 0.0 9.3 150 FTG 22.0 PE -4.3 9 25.0 0.0 18.7 0.0 0.163 TL 42.00 PV Pipe: 9 -4.8 0.874 PL 22.00 PF 0.6 8 25.0 0.0 18.1 0.0 2.5 150 FTG 22.0 PE 0.0 9 25.0 0.0 18.7 0.0 0.015 TL 44.00 PV Pipe: 10 13.4 0.874 PL 16.00 PF 4.3 8 25.0 0.0 18.1 0.0 7.2 150 FTG 27.0 PE -4.3 10 35.0 0.0 9.4 0.0 0.100 TL 43.00 PV Pipe: 11 12.7 0.874 PL 23.00 PP 5.0 9 25.0 0.0 18.7 0.0 6.8 150 FTG 32.0 PE -4.3 11 35.0 0.0 9.4 0.0 0.090 TL 55.00 PV Pipe: 12 0.4 0.874 PL 12.00 PF 0.0 10 35.0 0.0 9.4 0.0 0.2 150 FTG 18.0 PE 0.0 11 35.0 0.0 9.4 0.0 0.000 TL 30.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 PATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14 - 0 0 2 - 2 . S D F JOB TITLE: UNIT C - 2 HEAD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 13.0 0.874 PL 9.00 PF 2.4 10 35.0 0.0 9.4 0.0 7.0 150 FTG 16.0 PE 0.0 13 35.0 4.9 7.0 13.0 0.094 TL 25.00 PV Pipe: 14 13.1 0.874 FL 8.00 PF 2.2 11 35.0 0.0 9.4 0.0 7.0 150 FTG 15.0 PE 0.0 12 35.0 4.9 7.2 13.1 0.096 TL 23.00 PV NOTES (HASS) Calculations were performed by the HASS 8 . 4 c o m p u t e r p r o g r a m under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to pr o v i d e a n a v e r a g e imbalance at each node of 0.001 gpm and a m a x i m u m imbalance at any node of 0.006 gpm. Total pressure at each node is used i n b a l a n c i n g t h e s y s t e m . Maximum water velocity is 12.8 ft/sec a t p i p e 1 . Items listed in bold print on the co v e r s h e e t are automatically transferred from t h e c a l c u l a t i o n r e p o r t . Available pressure at source node 1 u n d e r f u l l f l o w c o n d i t i o n s i s 79.99 psi compared to the minimum requir e d p r e s s u r e o f 2 0 . 0 0 p s i . PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.101 2.53 6.33 2.53 6.33 7.59 1.27 1 2 . 6 6 1 2 . 6 6 6 . 3 3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 I5ATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-2.SDF JOB TITLE: UNIT C - 2 HEAD CALC PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 0.874 5.00 3.00 1.00 0.00 1.00 1.00 0.00 1.00 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 c Q)t a)JO 4 a) Cfl- U)-1 04 '0 Q) (V) Q4 Ej -° a) Q-' Q CO a) CO U C]) - a) Q4 WQ04-) IC] RHO) dO>, C!3 -Ha)) co U) a C') H C') I a) H C/) a J I J -- a) I U I H -) I) 0 0 0 H I 4J U) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-2.SDF JOB TITLE: UNIT C - 2 HEAD CALC CD 0 0 0 C') DDW)C14U)U)U)U) —aU)-H---- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002 - 2 . S D F JOB TITLE: UNIT C - 2 HEAD CALC WATER SUPPLY CURVE 84+ 0 \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ * <79.0 psi @ 500 gpm 77+ Flow Test Point 70+ x 63+ P 56+ R E I S S 49+ U R E 42+ ( I P I S I 35+ 28+ 21+ 14+ LEGEND X = Required Water Supply 67.18 psi @ 31.1 gpm 7+ I 0 = Available Water Supply I 79.99 psi @ 31.1 gpm 0++-+---+----+-----+ ------+ --------+--------+ ---- - - - - - + - - - - - - - - - - - + 200 300 400 500 600 700 800 900 1000 FLOW (GPM) SYMONS FIRE PROTECTION, INC. 1050 PIONEER WAY, SUITE R EL CAJON, CA 92020 LICENSE C16-682025 HYDRAULIC CALCULATIONS FOR BEACHWALK PROJECT UNIT D *** REMOTE AREA 2 HEAD CALC TYCO LF II CONC/FLAT FILE NUMBER: 14-002 DATE: 5-8-14 -DESIGN DATA- V OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose) FLOW AND PRESSURE (@ NODE 5 BOR): SPRINKLER K-FACTOR (ORIFICE SIZE) DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: R3 .05 gpm/256 sq. ft. 512 sq. ft. 2 sprinklers 26.2 gpm 31.2 gpm (5 gpm Hose STREAM) 26.2 gpm @ 37.3 psi 4.9 CANDI CAUDILLO CARLSBAD FIRE DEPT. WATER FLOW AVAILABILITY DATA: STATIC: 89 psi (-10% 80 PSI) RESIDUAL: 88 psi FLOW: 500 gpm WATER DEPARTMENT: CARLSBAD WATER 1-13-14 CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. ATLANTA, GA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-3.SDF JOE TITLED- UNIT D - 2 HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 80.0 79.0 500.0 80.0 31.2 73.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 73.8 31.2 2 3.0 - - - - 65.1 3 3.0 - - - - 61.1 - - - 4 5.0 - - - - 44.3 - - - 5 9.0 HOSE STREAM 37.3 5.0 6 15.0 - - - - 33.2 - - - 7 15.0 - - - - 28.7 - - - 8 25.0 - - - - 20.0 9 25.0 - - - - 20.5 10 35.0 - - - - 9.5 11 35.0 - - - - 9.5 - - - 12 35.0 K= 4.90 7.0 13.0 13 35.0 K= 4.90 7.3 13.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-3.SDF JOB TITLE:'UNIT D - 2 HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.2 0.995 PL 20.00 PF 7.4 1 0.0 SRCE 73.8 (N/A) 12.9 150 FTG TG PE -1.3 2 3.0 0.0 65.1 0.0 0.254 TL 29.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 3.0 0.0 65.1 0.0 4.0 psi, 31.2 gprn 3 3.0 0.0 61.1 0.0 Pipe: 3 31.2 1.101 PL 100.00 PF 16.0 3 3.0 0.0 61.1 0.0 10.5 150 FTG 3.0 PE -0.9 4 5.0 0.0 44.3 0.0 0.155 TL 103.00 PV Pipe: 4 31.2 1.025 PL 5.00 PF 5.3 4 5.0 0.0 44.3 0.0 12.1 150 FTG 19.0 PE -1.7 5 9.0 H.S. 37.3 5.0 0.219 TL 24.00 PV Pipe: 5 26.2 1.101 PL 6.00 PF 1.5 5 9.0 H.S. 37.3 5.0 8.8 150 FTG 7.0 PE -2.6 6 15.0 0.0 33.2 0.0 0.112 TL 13.00 PV Pipe: 6 10.2 0.874 PL 42.00 PF 4.5 6 15.0 0.0 33.2 0.0 5.5 150 FTG 32.0 PE 0.0 7 15.0 0.0 28.7 0.0 0.061 TL 74.00 PV Pipe: 7 10.2 0.874 PL 32.00 PF 4.4 7 15.0 0.0 28.7 0.0 5.5 150 FTG 40.0 PE -4.3 8 25.0 0.0 20.0 0.0 0.061 TL 72.00 PV Pipe: 8 16.0 0.874 PL 25.00 PF 8.4 6 15.0 0.0 33.2 0.0 8.5 150 FTG 36.0 PE -4.3 9 25.0 0.0 20.5 0.0 0.138 TL 61.00 PV Pipe: 9 -3.1 0.874 PL 35.00 PF 0.5 8 25.0 0.0 20.0 0.0 1.6 150 FTG 37.0 PE 0.0 9 25.0 0.0 20.5 0.0 0.007 TL 72.00 PV Pipe: 10 13.3 0.874 PL 24.00 PF 6.2 8 25.0 0.0 20.0 0.0 7.1 150 FTG 39.0 PE -4.3 10 35.0 0.0 9.5 0.0 0.099 TL 63.00 pv Pipe: 11 12.9 0.874 PL 34.00 PF 6.7 9 25.0 0.0 20.5 0.0 6.9 150 FTG 38.0 PE -4.3 11 35.0 0.0 9.5 0.0 0.093 TL 72.00 PV Pipe: 12 0.3 0.874 PL 12.00 PF 0.0 10 35.0 0.0 9.5 0.0 0.2 150 FTG 13.0 PE 0.0 11 35.0 0.0 9.5 0.0 0.000 TL 25.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-3.SDF JOB TITLE: UNIT D - 2 HEAD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 13.0 0.874 FL 10.00 PF 2.5 10 35.0 0.0 9.5 0.0 7.0 150 FTG 16.0 PE 0.0 12 35.0 4.9 7.0 13.0 0.094 TL 26.00 PV Pipe: 14 13.2 0.874 FL 8.00 PF 2.2 11 35.0 0.0 9.5 0.0 7.1 150 FTG 15.0 PE 0.0 13 35.0 4.9 7.3 13.2 0.097 TL 23.00 PV NOTES (HASS) Calculations were performed by the HASS 8.4 computer program under license no. 38071930 granted by MRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 65 9- 97 60 The system has been calculated to provide an average imbalance at each node of 0.011 gpm and a maximum imbalance at any node of 0.126 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 79.99 psi compared to the minimum required pressure of 20.00 Psi. PIPE FITTINGS TABLE Pipe Table Name: FSS.PIF PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.101 2.53 6.33 2.53 6.33 7.59 1.27 12.66 12.66 6.33 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002--3.SDF JOB TITLE:' UNIT D - 2 HEAD CALC PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Ell Tee TEERUN COUPLG EL45 0.874 5.00 3.00 1.00 0.00 1.00 1.00 0.00 1.00 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 E a)O ClC)U Q) • c'J /-/c'J>-,-0I (1). Cl n-/ a)c') 0)C')QE 4_) G) Cla) Q02) U))C/)04 0)-H Ha) H 0) - - 0 0) 0 0) Ql). a)a4- 10 H) CU) HO)O> (D -H/)) Cr-C/)C/) 04 31 H C -1 I (I) I a) H I C/) I I C C I C C H -) I Li) I I) I C C --C Li C --C C --c C --C 0 '-4 S SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-3.SDF JOB ITLE: UNIT D - 2 HEAD CALC 0 H cli C- 0 0 0 0 0 0 0 0 0 0 0 0 0 00 CD —Qo)-H--- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/8/2014 C:\PROGRAM FILES\HRS SYSTEMS\HASS\14-002-3.SDF JOB TITLE: UNIT D - 2 HEAD CALC WATER SUPPLY CURVE 84+ 0\\\\\\\\\\\\\\\\\ I * <790 psi @ 500 gpm 77+ Flow Test Point x 70+ 63+ P 56+ R I E I S 5 49+ U R I E I 42+ P S I I 35+ 28+ 21+ 14+ LEGEND X = Required Water Supply I 73.79 psi 8 31.2 gpm 7+ 0 = Available Water Supply if 79.99 psi @ 31.2 gpm +------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) ASt4o -Ai43 Worldwide www.tyco-fire.com Contacts JT Rapid Response Series LFII Residential 49 K-factor Concealed Pendent Sprinklers, Flat Plate Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Se- ries LFll Residential 4.9 K-factor Con- cealed Pendent Sprinklers (1Y3596) are decorative, fast response, fus- ible solder sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFlI Residential Concealed Pendent Sprinklers (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 130 wet and dry pipe residential sprin- kler systems for residential occu- pancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. The Series LFll Residential Concealed Pendent Sprinklers (1Y3596) has been designed with heat sensitivity and wa- ter distribution characteristics proven to help in the control of residential fires and to improve the chance for occu- pants to escape or be evacuated. The Series LFll Residential Concealed Pendent Sprinklers (1Y3596) are shipped with a Disposable Protective Cap. The Protective Cap is temporar- ily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Protective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFll Residential Concealed Pendent Sprinklers (TY3596) need not be increased over the number of de- sign sprinklers (hydraulic design area) as specified for wet pipe sprinkler sys- tems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFll Residen- tial Concealed Pendent Sprinklers of- fer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hy- draulic design area) for systems de- signed to NFPA 13, 130, or 13R. Non- water filled pipe will permit options for areas sensitive to freezing. UL.)lIg4 The Series LFII Residential Con- cealed Pendent Sprinklers (TY3596) described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having ju- risdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number TY3596 Page 1 of 6 APRIL 2013 TFP442 SPRINKLER- SUPPORT CUP ASSEMB OPERATE SPRINKLI COVER PLATE RETAINE 7/8' (22,2 MOUNTING I 1-1/8" 286 SURFACE \ / DISPOSABLE TIP PROTECTIVE CAP FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR 2-1/2' DIA. (63,5 mm) 71 1/2' (12,7 mm) FACE OF 1/2" \ / THREADED SPRINKLER NPT ADJUSTMENT FITTING 1-7/8±1/4" (47,6 mm ±6,4 mm) - DEFLECTOR IN OPERATED POSITION TFP442 Page 2 of 6 BODY '\ 77 SEALING (1/2 NPT) - ASSEMBLY IITff4I4Tn SPRINKLER SUPPORT COMPRESSION CUP WITH SCREW ROLL FORMED THREADS LEVER GUIDE PIN SOLDER LINK ELEMENT GUIDE PIN HOUSING DEFLECTOR (OPERATED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO RETAINER SUPPORT WITH THREAD CUP UNTIL DIMPLES MOUNTING L SURFACE IS FLUSH WITH CEILING EJECTION SPRING \ WRENCH RECESS 0 1 PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPEI8 SPRINKLER WRENCH SOLDER ' COVER PLATE/RETAINER '-__ COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) TFP442 Page 3 of 6 Technical Data Approvals: UL and C-UL Listed. NYC Approved under MEA 44-03-E-2 NSF Certified to NSF/ANSI 61 The TYCO RAPID RESPONSE Series LFIl Residential Concealed Pendent Sprinklers are only listed with the Se- ries LFII Concealed Cover Plates hav- ing a factory applied finish. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K=4.9 GPM/psi112 (70,6 LPM/bar112) Temperature Rating: 160°F (71°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment: 1/2 inch (12,7 mm) Finishes: Refer to Ordering Procedure section Physical Characteristics: Body.....................Brass Cap.....................Bronze Saddle ...................Brass Sealing Assembly.........Beryllium Nickel w/ TEFLON Soldered Link Halves ........Nickel Lever....................Bronze Compression Screw.........Brass Deflector..........Copper or Brass Guide Pin Housing .........Bronze Guide Pins .........Stainless Steel or Bronze Support Cup ...............Steel Cover Plate ..............Copper Retainer ..................Brass Cover Plate Ejection Spring ........ ...Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, falls away to expose the Sprin- kler Assembly. At this point the De- flector supported by the Arms drops down to its operated position. The fus- ible link of the Sprinkler Assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin- kler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFll Residential Concealed Pendent Sprinklers (1Y3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturers recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Ta- bles A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum re- quired discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ ft' over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of "design sprinklers" specified in NFPA 13 for wet pipe sys- tems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFll Residen- tial Concealed Pendent Sprinklers (TY3596) in dry pipe sprinkler systems, the time for water delivery must not ex- ceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described with- in the Technical Data Sheet TFP490. Operational Sensitivity. The sprin- klers are to be installed relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFll must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup- port Cup could delay sprinkler opera- tion in a fire situation. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure (b, Maximum Coverage Maximum Spacing Ordinary Temp. Rating Area °) Ft. 160°F (71°C) Minimum Ft. x Ft. (m) Deflector to Installation Spacing (m x m) Flow Pressure Ceiling Type Ft. GPM PSI (m) (1/mm) (bar) 12x12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) ceilings 7/8 to 1-1/8 14x14 14 13 7.0 inches (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed Ceilings per 8 16 x 16 16 13 7.0 (4,9 x 4,9) (4,9) (49,2) (0,48) NFPA 13D or Concealed 13R, (2,4) or 13. Installed in 18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64,3) (0,83) 7/8to1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6.1 x 6,1) (6,1) (75,7) (1,15) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure (b, C) Maximum Maximum Coverage Area(,) Spacing Ordinary Temp. Rating Minimum Ft. x Ft. Ft. 160°F (71°C) Deflector to Installation Spacing Flow Pressure (m x m) (m) Ceiling Type Ft. GPM PSI (m) (L/min) (bar) 12x12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14x14 14 14 8.2 inches (4,3x4,3) (4,3) (53,0) (0,57) Beamed Ceilings per 8 16 x 16 16 15 94 (4,9 x 4,9) (4,9) (56,8) (0,65) NFPA 13D or Concealed 13R, (2,4) or 13. Installed in 18x18 18 18 13.5 beam (5,5x5,5) (5,5) (68,1) (0,93) 7/8to1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gprri/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 50f6 Installation The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (1Y3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (i.e., do not apply pressure to the fusible Link Assembly). A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Cover Plate/Retainer Assembly by under-or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be in- stalled in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler/Sup- port Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceil- ing installation and/or during applica- tion of the finish coating of the ceil- ing. It may also be used to locate the center of the clearance hole by gen- tly pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service". Step 5. After the ceiling has been completed with the 2-1/2 inch (63 mm) diameter clearance hole and in prep- aration for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the De- flector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to modi- fy or repair a damaged sprinkler. Step 6. Screw on the Cover Plate As- sembly until its flange comes in con- tact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceil- ing panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Se- ries LFII Residential Concealed Pen- dent Sprinklers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may de- lay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 inch (3,2 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 3. This air gap is necessary for proper op- eration of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help as- sure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be re- placed, if necessary, by factory paint- ed units. Non-factory applied paint may adversely delay or prevent sprin- kler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age -before, during, and after installa- tion. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. The owner must assure that the sprin- klers are not used for hanging any ob- jects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP442 Page 6 of 6 Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability. Sprinkler Assembly: Series LFII (TY3596), K=4.9, Resi- dential Concealed Pendent Sprin- kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate Assembly: Cover Plate Assembly having a (spec- ify) finish for the Series LFll (1Y3596), K=4.9, Residential Concealed Pendent Sprinkler, P/N (specify) Ivory (RAL1015) ...........P/N 56-202-0-135 Beige (RAL1001)...........P/N 56-202-2-135 Pure White (b) (RAL9010) ... P/N 56-202-3-135 Signal White (a) (RAL9003) .. P/N 56-202-4-135 Grey White (RAL9002) ......P/N 56-202-5-135 Brown (RAL8028)..........P/N 56-202-6-135 Black (RAL9005) ..........P/N 56-202-7-135 Brushed Brass ............P/N 56-202-8-135 Brushed Chrome ..........P/N 56-202-9-135 Custom Paint .............P/N 56-202-X-135 Previously known as Bright White. Eastern Hemisphere sales only. Note: All Custom Cover Plates are painted us- ing Sherwin Williams Interior Latex Paint. Contact TYCO Customer Service with any questions re- lated to custom orders. Sprinkler Wrench: Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2012 Tyco Fire Products, LP. All rights reserved. NCO is trademark of The DuPont Corporation. 0 7 C " _Tii 7 Worldwide I www.tyco-fire.com Contacts RAPID RESPONSE Series LFII Residential Sprinklers 49 K-factor Pendent Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are deco- rative, fast response, frangible bulb sprinklers designed for use in residen- tial occupancies such as homes, apart- ments, dormitories, and hotels. When aesthetics and optimized flow charac- teristics are the major consideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-family dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The adjustment provided by the Recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (1Y2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. The Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable stan- dards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY2234 Page 1 of 6 APRIL 2013 TFP400 7/16 (11,1 mm) 1/2 ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 1 - Frame MAKE-IN SURFACE 2 -Button 3 - Sealing Assembly 4 - Bulb 1 4Pk 5 - Compression Screw 2 IIIIl I 6 -Deflector* (57,2 mm) 4 1-5/8' Temperature (41,3 mm) rating is indicated on 6* Deflector. CROSS SECTION PENDENT 2-7/8' DIA. (73,0 mm) VW7 WRENCH STYLE 20 FLATS RECESSED ESCUTCHEON RECESSED PENDENT Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass Pure or Signal White Chrome Plated Physical Characteristics Frame ....................Brass Button ...................Copper Sealing Assembly ........Beryllium Nickel w/TEFLON Bulb (3 mm) ................Glass Compression Screw ........Bronze Deflector .................Bronze Ejection Spring ......Stainless Steel TFP400 Page 2 of 6 FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) 2-7/8" DIA. • - (73,0 mm) 7/16±118" 1/2' (12,7 mm) (11,1±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I FACE OF (57,2 mm) SPRINKLER MOUNTING FITTING PLATE \ 'III MOUNTING 1/8" SURFACE/ (3,2mm) CLOSURE TY2234 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER (TY2234) Technical Data Approvals UL Listed for use with wet pipe and dry pipe systems C-UL Listed for use only with wet pipe systems NSF Certified to NSF/ANSI 61 For details on these approvals, refer to the Design Criteria section. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi112 (70,6 LPM/bar112) ^WRENCH RECESS / (END "A" USED FOR 1Y2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP400 Page 3 of 6 Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a func- tion of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of "design sprinklers" specified in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (TY2234) in dry pipe sprin- kler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as appli- cable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be installed in accor- dance with this section: General Instructions Do not install any bulb type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 -to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprin- kler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFII Residential Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFII Residential Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. Install recessed pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. (Continued on Page 5) TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Max. Ordinary Temp. Rating Intermediate Temp. Rating Coverage Area (a) 155°F (68°C) 175°F (79°C) to Minimum Deflector Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (mx m) GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 4inches 14x14 13 7.0 13 7.0 (4,3 x 4,3) (49,2) (0,48) (49,2) (0,48) Beamed Recessed using Style 20 Escutcheon or 8 16 x 16 13 7.0 13 7.0 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) Ceilings per 13D or 13R non-recessed per NFPA 13D, 13R, or 13 (2,4)NEPA 18 x 18 17 12.0 17 12.0 (5,5x5,5) (64,3) (0,83) (64,3) (0,83) 11/4t013/4 inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x6,1) (75,7) (1,15) (75,7) (1.15) beam. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 131?, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressurelb, cl Coverage Area (a) Ordinary Temp. Rating Intermediate Temp. Rating Minimum 155°F (68°C) 175°F (79°C) Ft. x Ft. Deflector to Installation Spacing Flow Pressure Flow Pressure (m x m) Ceiling Type Ft. GPM PSI GPM PSI (m) (L/min) (bar) (1/mm) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 4 inches 14 X 14 14 8.2 14 8.2 (4,3 x 4,3) (53,0) (0,57) (53,0) (0,57) Beamed Recessed using Style 20 Escutcheon or 8 16 x 16 15 9.4 15 9.4 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) Ceilings per NFPA 13D or 13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18 x 18 18 13.5 18 13.5 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 21 18.4 21 18.4 (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) 1 beam. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 131?, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 5 of 6 Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFll Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO RAPID RESPONSE Series LFll Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; other- wise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly Specify: Series LFII (1Y2234), K=4.9, Residential Pendent Sprinkler, (specify) temperature rating, (specify) finish, P/N (specify). 155°F (68°C) Natural Brass ..............P/N 51-201-1-155 Pure White (RAL 9010)° ......P/N 51-201-3-155 Signal White (RAL 9003) .....P/N 51-201-4-155 Chrome Plated .............P/N 51-201-9-155 175°F (79°C) Natural Brass ..............P/N 51-201-1-175 Pure White (PAL 9010)° ......P/N 51-201-3-175 Signal White (RAL 9003) .....P/N 51-201-4-175 Chrome Plated .............P/N 51-201-9-175 °Eastern Hemisphere sales only. Recessed Escutcheon Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*). *Refer to Technical Data Sheet TFP77O. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. December 12, 2013 Sprinkler 41a -MCHNICALTDATA R JR ESPONSE PENDENT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP5 Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In ad- dition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resist- ant.) LISTINGS AND APPROVALS cULus Listed: Category VNlV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 F I, PN 12979 PN 06666B ABS Certified: Certificate 04-H5407984C-PDA vds VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0786-CPD-40130, 0786-CPD-40170 and 0786-CPD- 40279, 0832-CPD-2001, and 0832-CPD-2003 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- http:/Iwww.vikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12979 and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 12979, 06666B, and 06765B. Copper UNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-051 000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT coated. Form No. F081296 Replaces page 41a-f, dated December 4, 2013. - (Added E-3 Escutcheon) Wrench Flat Protect Sprirk1 SheLo Protective Sprink1er Cp ,D= 10896 ~3 'Sprinkler 41 b December 12, 2013 MICROFAST®AND MicrofastHP®QUICk RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Microfast and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-AN, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, and 286°F (141 °C) = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155°F (68 *C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the 'Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B* (available since 2011) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) *A 1/2 ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 197 1) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance require- ments. AVAILABILITY The Viking Microfast and MicrofastHP0 Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 10896W/B becembr 12, 2013 Sprinkler 41c -MICROFASTD AND 4 -RESPONSE PENDENT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature- Bulb Color Ordinary 135 °F(57 °C) 100 °F(38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F(141 °C) 225 °F(107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C). Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. - Sprinkler- wrench I s - - - 16O36W/Bi for installing recessed pendent sprinklers AAA 1/2' ratchet is r'eqi1e (notavaiisbie From Viking), Carefully slide the wrench sideways around the protective cap, ensuring engage- ment with the sprinkler wrench flats. Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers sprinkler 41d December 12, 2013 '7 T MICROFAST®AND !4., A MicrofastHP® QUICK Li L ir RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikinocorn.cnm Approval Chart I (UL) rT rnpei tur KEY Microfast and Mic1rofastHPI Quick Response Pendent Sprinklers Fnsh A1XI-- Ev 7th on (if ppliab1e __ Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT FBSP U.S. J metric2 Inches J mm cULus4 NYC5 I VdS LPCB I s Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 57 AiX, BIY, C4, E4Z AiX, B1Y -- - - 1 - 18021 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 AiX, B1Y AiX, B1Y I A2 A2X, B2Y C2X, E2Y71 j C2X, E2Y14 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 AiX, B1Y, C4, E4Z AiX, B1Y A2 A2X C2h1 -- 06765B15 VK352 1/2" 15 mm 8.0 1 115.2 2-3/8" 60 1 AiX, B1Y, C4, E4Z AiX, B1Y A2 -- A2'2 -- _________ Small Orifice' 0671889 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AiX, B1Y AiX, B1Y -- -- -- -- 06720139 VK331 1/2" 15 mm 4.2 57 2-1/4" 58 AiX, B1Y Al X, B1Y -. -- -- -- 06932B VK331 -- 10 mm 4.2 57 2-3/8" 60 - -- A2 -- f G313 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. I metric2 Inches mm cULus4 NYC'- VdS LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 AiX, B1Y AiX - -- -- -- Maximum 250 PSI (17 bar) WWP Small Orifice' 1229070 VK342 1/2" 15 mm 2.8 1 40.3 1 2-3/16" 1 56 AiX, B1Y AiX -- -- -- -- Approved Temperature Ratings A - 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286 OF (141 °C) Approved Escutcheons B - 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), and 200 °F (93 Approved Finishes 1 - Brass, Chrome, White Polyester67, Black X - Standard surface-mounted escutcheon or the Viking Microfast® Model F-i Adjustable C) Polyestere?, and Black PTFE5 Escutcheon C - 155 OF (68 °C), 175°F (79 °C), 200 OF (93 °C), and 286°F (141 °C) 2 - Brass, Chrome, White Polyester', and Black y - Standard surface-mounted escutcheon or the Polyester7 Viking Microfast5Model F-i Adjustable Escutcheon °C), D - 135°F (57 155°F (68 °C), 175 OF (79 °C), and 286°F (141 3- Brass and Chrome or recessed with the Viking Micromatic8 Model E- °C) 4 ENT6 1, E-2, or E-3 Recessed Escutcheon E - 155 OF (68 °C), 175 OF (79 °C), and 200 OF (93 °C) Z - Standard surface-mounted escutcheon or re- F- 155 OF (68 °C), 175 OF (79 °C), and 286 OF (141 °C) cessed with the Viking Micromatica Model E-1 G - 155°F (68 °C) Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 6 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 6 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. '°Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. "((Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. 12 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40279. 11 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 14 0 MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit Only. 1-3/4' (44,5 mm) Maximum 1-1/8" (28.6 mm) Minimum December 12, 2013 Sprinkler 41e The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com P DESIGN CRITERIA - UL r L p p r 1 4 id - cULus Listing Requirements: Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception. small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_09 1699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size 2-5/16' (58.7 mm) minimum J 2-1/8' I 2-1/2' (63,5 mm) maximum (54 ) !. 8t8O8. 2' / 1-1/2' (38,1 mm) (50.8 mm) I Minimum Maximum L Installed with o Microfst Model F-i Adjustable Escutcheon 1/2' (15 rim) NPT 2-1/4' 1-5/8' (58 mm) (41 mm) Pendent Sprinkler 1-3/4' (44,5 mm) Installed with a standard 1/8' surface- mounted escutcheon, S Note: At maximum, adopter is exposed 1/2' (12.7 mm) from face of ceiling. Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/8' Ceiling Opening Size 2-1/8' (54 mm) - 2-5/16' (58.7 mm) minimum (54 mm) 2-1/2' (63.5 mm) maximum Installed with a Micromatic Model E-1 Recessed Escutcheon 2" ) / 1-1/8' (28.6 mm) (50,8 mm) \)J Minimum Maximum Installed with a thread on Model E-2 Recessed Escutcheon Sprinkler 41f December 12, 2013 MICROFAST® AND MicrofastHPO QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temp KEY Microfastm Quick Response Pendent Sprinklers Fnh Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Base Part No.' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 j Inches j mm Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 57 A2X, 132Y, C3, D3Z 18021 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A2X, 82Y Large Orifice 06666B VK352 1 3/4" 20mm 1 8.0 1 115.2 2-3/8" 60 j A2X, B2Y, C3, D3Z 06765B7 VK352 1 1/2" 1 15 mm 8.0 115.2 1 2-3/8" 60 A2X, B2Y, C3, D3Z Small Orifice 06718136 VK329 1 1/2" 1 15 mm 2.8 40.3 2-3/16" 56 AiX Approved Temperature Ratings Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C) X - Standard surface-mounted escutcheon or the Viking 200 °F (93 °C), and 286 °F (141 °C) Approved Finishes Microfast6 Model F-i Adjustable Escutcheon B - 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 1 - Brass and Chrome Y - Standard surface-mounted escutcheon or the and 200 °F (93 °C) 2 - Brass, Chrome, White Polyester5, and Viking Microfast5 Model F-i Adjustable Escutcheon C- 155 °F (68 °C), 175 °F (79 °C), 200°F (93 °C), Black Polyester5 or recessed with the Viking Micromatic Model E-i, and 286 °F (141 °C) 3 - ENT E-2, or E-3 Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F Z - Standard surface-mounted escutcheon or recessed (93 C) with the Viking Micromatic5 Model E-i Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Listings and Approvals as the standard colors. 6 The sprinkler orifice is bushed. The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. 8 FM approved as corrosion resistant. DESIGN CRITERIA - FM o refer to Approval Chart 2 above) FM Approval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requiremen t s , hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. tSprinklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for gen-eral care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated December 4, 2013. (Added E-3 Escutcheon) '-