HomeMy WebLinkAbout7615 VIA CAMPANILE; 120; AS140256; Permitity 01 uarisaa Sprinkler Permit Permit No: AS140256 7615 VIA Job Address: Status: ISSUED CAMPANILE Permit Type: SPRINK Applied 9/19/2014 Parcel No: 2230507200 Approved: 10/1/2014 Lot #: 0 Reference No.: Issued: 10/1/2014 PC #: Inspector: Project Title: STARBUCKS COFFEE INSTALL NEW PIPING AND SPRINKLERS AS SHOWN ON THIS DRAWING UNDER THIS CONTRACT. ADD NEW HEADS FOR RE-WORK OF EXISTING DROPS FOR NEW CEILING & WALLS. ALL NEW WALLS ARE PARTITION WALLS ENDING JUST ABOVE CEILING EXCEPT AS NOTED. BUILDING CONSTRUCTION IS COMBUSTIBLE. ALL MODIFICATIONS PER NFPA#13 2013, CARLSBAD FIRE DEPT. Applicant: PARAMOUNT FIRE SYSTEMS, INC. P.O. BOX 713194 SANTEE, CA 619-562-6247 Owner: PROPERTY DEVELOPMENT CENTERS L LC C/O SAFEWAY INC 5918 STONERIDGE MALL RD PLEASANTON CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 280 0 280 0 I AS140256/// vvuridwide t"LI Fire Protection Contacts www.tyco-fire.com Products Series TY-B, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers described in this data sheet are standard response, standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-B Sprinklers are described in Technical Data Sheet TFP352. Sprinkler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The Series TY-B Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main fain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Numbers (SINs) TY315 ......Upright 5.6K, 1/2" NPT Pendent 5.6K, 1/2 NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion- Resistant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K = 5.6 GPM/psi112 (80,6 LPM/bar1/2) FEBRUARY 2014 Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C)t t UL, C-UL, and VdS Approved only Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI52 TFPI52 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector, can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6- Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 1 7/16 (11,1 mm) I NOMINAL MAKE-IN 2' (50,8 mm) 1/2 NPT** (50,8 mm) WRENCH FLATS DEFLECTOR * b-.--- 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT (TY315) AND PENDENT (TY325) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Loss Preven- tion Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (1Y325) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TV-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS (USE ONLY END "A") FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI52 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TV-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate, as applicable, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 15 or Style 20 Closure over the Series TV-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Thereafter, annual inspections per NFPA 25 are required; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. 2-7/8 DIA. - (73,0 mm) 2-1/4 DIA. FACE OF - (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) FLUSH MOUNTING \ J SURFACE/// (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) Ty-B PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. - (73,0 mm) FACE OF SPRINKLER - 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4' 1/2(12,7mm) (7,9±6,4 mm) FLUSH fil MOUNTING SURFACE/&(3,2/8rm, m) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI52 Page 4 of 4 P/N*77_XXX_X_XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS I570 I 5.6K UPRIGHT (1/2-NPT) TY315 1 NATURAL BRASS 571 5.6K PENDENT (1/2" NPT) TY325 POLYESTER PURE WHITE (RAL9O1O)** Use suffix "1" for ISO 7-1 connection; for example, 77-570-4-175-I SIGNAL WHITE (RAL9003) POLYESTER 175 175-F (79-C) 9 CHROME PLATED ** Eastern Hemisphere sales only OPEN indicates sprinkler assembly without Glass Bulb. Button, and Sealing Assembly TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F(57°C) 155 155°F(68°C) 200 200°F (93°C) 286 286°F (141°C) 360 360°F (182°C) 000 OPEN*** Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (PIN). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating, (specify) finish, PIN (specify, refer to Table A) Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, PIN (specify*) Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products