Loading...
HomeMy WebLinkAbout7610 VIA CAMPANILE; 150; AS140276; PermitSprinkler Permit Permit No: AS 140276 7610 VIA Job Address: Status: ISSUED CAMPANILE Permit Type: SPRINK Applied 10/29/2014 Parcel No: 2230507200 Approved: 11/13/2014 Lot #: 0 Reference No.: Issued: 11/13/2014 PC #: Inspector: Project Title: TOMOYAMA SUSHI INSTALL NEW TI PIPING AND SPRINKLERS AS SHOWN ON THE PLANS UNDER THIS CONTRACT. ADD NEW HEADS FOR RE-WORK OF EXISTING DROPS FOR NEW CEILING & WALLS. ALL NEW WALLS ARE PARTITION WALLS ENDING JUST ABOVE CEILING EXCEPT AS NOTES. BLDG CONSTRUCTION IS COMBUSTIBLE. ALL MODIFICAITONS PER NFPA #13 2013, CFD. ADD AND RELOCATED FIRE SPRINKLERS FOR NEW CEILING HEIGHT CHANGE AND NEW WALLS BUILIDNG IS PROTECTED BY EXISTING FIRE SPRINKLERS. Applicant: PARAMOUNT FIRE SYSTEMS, INC. P.O. BOX 713194 SANTEE, CA 619-562-6247 Owner: PROPERTY DEVELOPMENT CENTERS L LC C/O SAFEWAY INC 5918 STONERIDGE MALL RD PLEASANTON CA Fees ($) I Add'I Fees ($) Total ($) Balance 9$fl n 9.q n I Worldwide www.tyco-fire.com Contacts Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions I with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2NPT TY323 ......Pendent 5.6K, 1/2 NPT Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi'/2 (80,6 LPM/barl'2) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) JANUARY 2013 Finishes Sprinkler: Natural Brass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze ASI 40276 TFPI72 2-7/8" (73,0 mm) DIA. TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN 7/16 (11,1 mm) NOMINAL " mm) ____ MAKE-IN (50,8 2' I I ) WF (50,8 mm) 3 m ______ (34,9m) Fl 1/2' NPT** DEFLECTOR* STYLE 15 or 20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (1Y313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers mustbe installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated,. or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8' DIA. (73,0 mm) 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) FLUSH 3/8±5/16' 17 (9,5±7,9 mm) MOUNTING 1 J / SURFACE \ (3.2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. - (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4" \ 1/2 (12,7 mm) (7,9±6,4 mm) FLUSH I MOUNTING l/8"J I SURFACE/// (3,2 mm) I CLOSURE SERIES MOUNTING 1-3/8(34,9mm) TYFRB PLATE 7/8" (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 PIN* 77 - XXX - X - XXX I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2 NPT) TY313 4 SIGNAL WHITE (RAL 9003) 371 5.6K PENDENT (1/2NPT) TY323 3 PURE WHITE (RAL 9010)** Use suffix 'I' for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I ** Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS - PART NUMBER SELECTION - Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (SIN), K=5.6, (Upright or Pendent) Sprinkler Quick Response, (specify) temperature rat- ing, (specify) finish, P/N (Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 135 135°F(57°C) 155 155°F (68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tuco TEFLON is trademark of The DuPont Corporation. x tqC0 /Fire & Building I Products AS140276 Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series DS-1 - 56 K-factor Dry Type Sprinklers Quick Response, Standard Coverage General Description The Series DS-1, 5.6 K-factor, Quick Response, Standard Coverage, Dry Type Sprinklers are decorative 3 mm glass bulb automatic sprinklers de- signed for the following typical uses: where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing tempera- tures (e.g. sprinkler drops from un- heated portions of buildings) where sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler sprigs from wet systems into un- heated attics, or horizontal piping extensions through a wall to pro- tect an unheated area of a build- ing) where sprinklers are used on sys- tems that are seasonably drained to avoid freezing (e.g. vacation re- sort areas) WARNINGS The Series DS-1 Dry Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS-1 Dry Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers TY3235 - (Pendent) TY3135 - (Upright) TY3335 - (Horizontal Sidewall) Technical Data Approvals UL and C-UL Listed. FM and NYC Approved. (Refer to Table A) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient K = 5.6 GPMIpsi1/2 (80,6 LPM/barl/2) Temperature Ratings Refer to Table A Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated Physical Characteristics Inlet ..............Copper Plug .............Copper Yoke .........Stainless Steel Casing . Galvanized Carbon Steel Insert .............Bronze Bulb Seat ......Stainless Steel Bulb ..............Glass Compression Screw .....Bronze Deflector ...........Bronze Frame ............Bronze Guide Tube ......Stainless Steel Water Tube ......Stainless Steel Spring ........Stainless Steel Sealing Assembly .......... Beryllium Nickel w/Teflon* Escutcheon ......Carbon Steel *Registered Trademark of DuPont Patents U.S.A. Patent No. 5,188,185 Page 1 of 8 APRIL, 2004 TFP5IO Page 2 of 8 TFP5IO TY3235 Pendent W/ Standard Recessed Escutcheon (Ref. Fig. 3) W/ Wide Flange Recessed Escutcheon (Ref. Fig. 4) SPRINKLER FINISH TY3235 Pendent wl Std. Escutcheon (Ref. Fig. 5) wl Deep Escutcheon (Ref. Fig. 6) w/o Escutcheon (Ref. Fig. 7) TY3135 Upright w/o Escutcheon (Ref. Fig. 8) TY3335 Hor. Sidewall with top of Deflector-to-Ceiling distance of 4 to 12 inches (100 to 300 mm) w/ Std. Escutcheon (Ref. Fig. 9) w/ Deep Escutcheon (Ref. Fig. 10) w/o Escutcheon (Ref. Fla. lB Temperature Rating Bulb Color Code Natural Brass Chrome Plated White Polyester I Natural Brass IChrome Plated White Polyester I Natural Brass lChrome Plated White Polyester 135°F/57°C Orange 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*,2*,3**,4 1*,2*,4 155°F/68°C Red 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*,2*,3**,4 1*,2*,4 175°F/79°C Yellow 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*, 2*, 3** 4 1*, 2*, 4 200*F/93*C Green 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*, 2*, 3** 4 1*, 2*, 4 286*F/141*C I Blue I N/A 1,2,3,4 1,2,4 1*, 2*, 3** 4 1*, 2*, 4 Notes: Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). Listed by Underwriters Laboratories for use in Canada. (Maximum order length of 48 inches). Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) Approved by the City of New York under MEA 352-01-E. * Light and Ordinary Hazard Occupancies Only. ** Light Hazard Occupancies Only. N/A- Not Available. TABLE A SERIES DS-1, QUICK RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET GASKETED SPRING PLATE SEAL --- YOKE SPRING CASING WATER TUBE H INSERT GUIDE TUBE BULB SEAT FRAME " 3 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 QUICK RESPONSE DRY TYPE SPRINKLER ASSEMBLY WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 SPRINKLER WRENCH TFP5IO Page 3 of 8 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ------------ - - FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-1/2' to 48' (88,9 to 1219,2 mm) IN 1/4' (6,4 mm) 2-1/4" DIA. INCREMENTS (57,2 mm) FACE OF CEILING (34,9 (73 mm) FIGURE 3 TY3235 PENDENT wi STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) rJ FACE OF SPRINKLER U Lj FITTING ORDER LENGTHS: 3-1/2" DIA. 1/2" to 46" (88,9 mm) (12,7 to 1168,4 mm) 21/DJ INCREMENTS (6315 FACE OF CEILING 4-1/4" ± 1/8" (108,0 ±3,2 mm) FIGURE 6 TY3235 PENDENT wi DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER L FITTING ORDER LENGTHS: 3-1/2" to 48" (88,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS (76,2 mn FACE OF CEILING 7~r—1 1-3/8' ± 1/8" (34,9 ± 3,2 mm) FIGURE 4 TY3235 PENDENT wi WIDE FLANGE RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF L--t-- SPRINKLER L: FITTING 1L ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE 7 TY3235 PENDENT wlo ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) 11 --- -------- FACE OF SPRINKLER FITTING L 1L ORDER LENGTHS: 2-1/2" to 48" 1-3/4" DIA. (63,5 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) INCREMENTS I J FACE OF CEILING 2-3/16" ± 1/8" (55,6 ± 3,2 mm) FIGURE 5 TY3235 PENDENT wl STANDARD ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING U [i SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 8 TY3135 UPRIGHT w/o ESCUTCHEON ORDER LENGTHS: 2-1/2' to 48" (63,5 to 1219,2 mm) IN 1/4'(6,4 mm) INCREMENTS 4 ±1/8 (101,6 ± 3,2 mm) FACE OF FACE OF 1-3f4 DIA. SPRINKLER MOUNTING (44,5 mm) FITTING SU4RFACE 3'DIA. (76,2 mm) 350 SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TV3335 HORIZONTAL SIDEWALL wISTANDARD ESCUTCHEON ORDER LENGTHS: FACE OF 1f2 1045-3/4" (12,7 toll 62,1 mm) MOUNTING IN 1/4" (6,4 mm) INCREMENTS SURFACE 4-13/16" ± 1/8" 121/2 DIAH (122,2 ±3,2 mm) FACE OF (635 mm) SPRINKLER FITTING 3-1/2" DIA. (88,9 mm) TTI I ---- * SPRINKLER (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 10 TY3335 HORIZONTAL SIDEWALL WI DEEP ESCUTCHEON ORDER LENGTHS: 5" 1o48" (127,010 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF [— SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) MINIMUM 2-1/4 (57,2 mm) DEFLECTOR TO MOUNTING SURFACE FI I • 5/16" / (7,9 mm) CENTERLINE OF WATERWAY FIGURE 11 TV3335 HORIZONTAL SIDEWALL w/o ESCUTCHEON Page 4 of 8 TFP5IO Operation When the Series DS-1 is in service, water is prevented from entering the assembly by the Plug & Belleville Seal- ing Assembly (Ref. Figure 1) in the Inlet of the Sprinkler. The glass Bulb contains a fluid that expands when ex- posed to heat. When the rated tem- perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to ex- pand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville Seal from the Inlet allowing the sprin- kler to activate and flow water. Design Criteria The Series DS-1 Sprinklers are in- tended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The Series DS-1 Dry Type Sprinkler is to be installed in the 1 inch NPT outlet or run of malleable or ductile iron threaded tee fittings that meet the di- mensional requirements of ANSI B16.3 (Class 150) or cast iron threaded tee fittings that meet the di- mensional requirements of ANSI B16.4 (Class 125) with the end sprin- kler fitting on a branch line to be plugged as shown in Figures 3 - 11. When installing 1 inch NPT Series DS-1 Dry Type Sprinklers on a dry pipe sprinkler system, only use the side outlet of maximum 2-1/2 inch size re- ducing tee's. For wet pipe sprinkler systems, the Series DS-1 Dry Type Sprinklers may also be installed in the 1 inch NPT outlet of a Central Figure 730 Me- chanical Tee or the following Tyco Fire Products CPVC fittings: (P/N 80145) 1 x 1' NPT Female Adapter or (P/N 80249)1 x 1 x 1 NPT Sprinkler Head Adapter Tee. NOTE Do not install the Series DS- 1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or binding of the inlet Plug; or, insufficient en- TFP5IO Page 5 of 8 gagementof the inlet pipe threads with consequent leakage. Branch, cross, and feedmain piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protecting areas subject to freezing temperatures (e.g., sprinkler drops into freezers), consideration must be given to the ap- propriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduction. When the temperature surrounding the wet pipe sprinkler system is main- tained at a minimum temperature of 40°F14°C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 40°F14°C): 12 inches (300 mm) when the tem- perature within the protected area is -20°F/-29°C 18 inches (450 mm) when the tem- perature within the protected area is -40°F/-400C 24 inches (600 mm) when the tem- perature within the protected area is -60°F/-51°C For protected area temperatures be- tween those given above, the minimum recommended length from the face of the fitting to the outside of the pro- tected area may be determined by in- terpolating between the indicated val- ues. NOTE When Dry Sprinklers penetrate a ceil- ing or wall into an area subject to freez- ing, the clearance space around the Sprinkler Casing must be completely sealed in order to prevent the leakage of moist air into the freezing area which might result in the formation of condensate around the Frame, Deflec- tor, Bulb Seat, or Bulb. Failure to pre- vent the formation of condensate could result in the build-up of ice around the releasing components. This could re- sult an inadvertent operation of the sprinkler or impaired operation due to reduced thermal sensitivity. Installation The Series DS-1 Dry Type Sprinklers must be installed in accordance with the following instructions: NOTES The Series DS- 1 must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C rating to 1/8 inch (3,2 mm) for the 286 °F/14 1°C rating. A leak tight 1 inch NPT sprinkler joint should be obtained with a torque of 20 to 30 ft.lbs. (26,8 to 40,2 Nm). Higher levels of torque may distort the sprin- kler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent position, and upright sprinklers must be in- stalled only in the upright position. The deflector of a pendent or upright sprin- kler is to be parallel to the ceiling. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpen- dicular to the back wall and parallel to the ceiling. The word "TOP" on the De- flector is to face towards the ceiling. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, use a W-Type 7 Sprinkler Wrench (Ref. Figure 2). The wrench recess of the W-Type 7 is to be applied to the sprinkler wrench flats (Ref. Figure 2). Step 4. After the ceiling/wall has been installed/finished, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Deep Escutcheon, hold the outer piece in contact with the mounting sur- face (ceiling), and then rotate the inner piece approximately 1/4 turn with re- spect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The Series DS-1 Dry Type Sprinklers must be maintained and serviced in accordance with the following instruc- tions: NOTES Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole is an indication that there may be weepage past the Inlet seal and that the sprinkler needs to be removed for determining the cause of leakage (e.g. an improper installation or an ice plug). The fire protection system control valve must be closed and the system drained before removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- Page 6 of 8 TF5IO ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure Contact your local distributor for avail- ability, and please specify the follow- ing: 1. Sprinkler. Model/SIN. Quick Response, Standard Cover- age, Dry Type Sprinkler Deflector Style. 5.6 K-factor. Order Length. Dry Type Sprinklers are furnished based upon Order Length as measured per Figure 3 through 11, as applicable. After the meas- urement is taken, round it to the nearest 1/4 inch increment. Inlet Connection (1 Inch NPT or ISO 7-Ri). Temperature Rating. Sprinkler Finish. Escutcheon Style and Finish, as applicable. Part Number from Table B. (Part numbers are for 1 inch NPT stand- ard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description.) 2. W-Type 7 Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers. TFP5IO Page 7 of 8 P/N 60-XXX--X-XXX I I __________ SPRINKLER ESCUTCHEON MODEL/SIN FINISH FINISH (2) 36 Pendent wi Standard 1Y3235 Escutcheon (1" NPT) (Fig. 5) 33 Pendent wi Deep TY3235 Escutcheon (1' NPT) (Fig. 6) 37 Pendent wi Std. Recessed TY3235 Escutcheon (1" NPT) (Fig. 3) 32 Pendent w/o Escutcheon TY3235 Escutcheon (1" NPT) (Fig. 7) 1 NATURAL BRASS WHITE T WHITE POLYESTER WHITE 9 CHROME PLATED CHROME PLATED 0 CHROME PLATED WHITE 3 1 WHITE (RAL9010)* WHITE (RAL9010)" I I ORDER LENGTH (1) (EXAMPLES) 055 5.50 082 8.25 180 18.00' 187 18.75" 372 37.25" 480 48.00" TEMPERATURE RATING (3) 0 135F/57C 1 155F/68C 2 175F/79C 3 200F/93C 4 286F1141C 34 Sidewall wl Standard TY3335 Escutcheon (1" NPT) (Fig. 9) 43 Sidewall W/ Deep TY3335 Escutcheon (1' NPT) (Fig. 10) 44 Sidewall w/o TY3335 Escutcheon (1" NPT) 1 (Fig. 11) L_______ 38 1 Upright w/o Escutcheon TY3135 (1' NPT) (Fig. 8) Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the meas- urement is taken, round it to the nearest 1/4 inch increment. Escutcheon Finish applies to sprinklers provided with escutcheons. The 286171141C temperature rating applies to non-recessed sprinkler assemblies. * Eastern Hemisphere sales only. TABLE B PART NUMBER SELECTION SERIES DS-1, QUICK RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "I" for ISO 7-R1 Connection, e.g., I-60-361-1-180) Page 8 of 8 TF5IO TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446