Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; FA080068; PermitCity ot Carlsbad Fire Alarm Permit Permit No: FA080068 5781 VAN ALLEN Job Address: WY Permit Type: FALARM Parcel No: 2121304400 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 10/8/2008 Approved: 10/9/2008 Issued: 10/9/2008 Inspector: Project Title: INVITROGEN CP-13D, 1ST FLOOR TI FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: ADT SECURITY SERVICES, INC. 3830 CALLE FORTUNADA SAN DIEGO, CA (858) 654-3224 Owner: GRIFFIN CAPITAL CARLSBAD POINTE INVESTORS L L C C/O INVITROGEN CORPORATION 1600 FARADAY AVE CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) L 125 0 125 INVITROGEN 5781 VAN ALLEN WAY CARLSBAD, CA. 92008 FIRE ALARM T.I. SUBMITTAL Submitted By: 3830 Calle Fortunada San Diego, CA 92123 RLE COPY (858) 654-3133 Lic. # 707408 Contact: DAVE WELLS INVITROGEN T.I. FIRE ALARM SUBMITTAL QTY DESCRIPTION MODEL # MANF. CSFM# 3 INPUT MODULE MMF-300 FIRE LITE 7300-0075:185 5 HORN/STROBE MULTI-CD WALL AS-24MCW WHEELOCK 7125-0785:131 LOT 14/2 FIRE CABLE ADT/GENESIS 7161-1487:100 LOT 18/2 FIRE CABLE ADT/GENESIS 7161-1487:100 df-52121:al •E-325 MMF-300(A) Series! MDF-300 Addressable Monitor Modules General Four different monitor modules are available for Fire-Lite's Intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact Input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4' [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact Input devices. MMF-301 is a miniature monitor module (a more 1.3' (3.302 cm) H x 2.75' (6.985 cm) W x 0.5' (1.270 cm) 0) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted In a single-gang box behind the device it monitors. UMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style 0) or Class B (Style B) circuit. MDF-300 Is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact Initiating device circuits (IDCS) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeodTm is a communication protocol developed by flre4Jte Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU,' stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF.300 Monitor Module Built-in type identification automatically Identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 -99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is Intended for use In intelligent, two-wire systems, where the Individual address of each mod- ule Is selected using the built-In rotary rwitches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (I DC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED Indicator. The MMF-300 can be used to replace M300 modules in existing systems. .:_.!).'R r-e,-UTaALarms by Honeywell IiiI.l j - [I! !1l A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. UUF-300 OPERATION Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of Its Initiating Device Circuit (lDC). A fleshing LED indicates that the module is In communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). UUF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 pA (LED flashing). Maximum IDC wiring resIstance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). HumIdity range: 101/6 to 93% noncondenslng. DImensions: 4.5' (11.43 cm) high x 4' (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125' (5.398 cm) deep box. detail of MDF400 - not "one" addresses are I 4,6,8 only UUF-300 APPLICATIONS MMF-301 Mini Monitor Module Use to monitor a zone of four-wire smoke detectors, manual tire alarm pull stations, waterf low devices, or other normally- • Built-In type identification automatically identifies this device open dry-contact alarm activation devices. May also be used as a monitor module to the panel. to monitor normally-open supervisory devices with special • Powered directly by two-wire FACP. No additional power supervisory Indication at the control panel. Monitored circuit require& may be wired as an NFPA Style B (Class B) or Style D (Class dt-52121:al .04128108—Page 1 of High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-8600 series panels. 01 -99 on other compatible systems. 1415 Q 1 ADDRESS 12 )3 3 iik/4R 14 LO P 4 10 5 M-5 7 9--," 6 I TENS ONES - O itLu citti ç) -J IIO The MMF-301 Mini Monitor Module can be Installed In a sin- gle-gang junction directly behind the monitored unit its small size and light weight allow It to be Installed without rigid mount- ing. The MMF-301 Is intended for use In IntellIgent, two-wire systems where the individual address of each module Is selected using rotary switches. It provides a two-wire Initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules In exist- ing systems. MUF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual tire alarm pull stations, waterf low devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. UMF-301 OPERATION Each MMF-301 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). UUF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. Maximum IDC wiring resIstance: 1,500 ohms. EOL resistance; 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondenslng. Dimensions: 1.3' (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65 (1.651 cm) deep. Wire length: 6' (15.24 cm) minimum. MMF-302 Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module Is selected using built-in rotary switches. This module allows intelligent panels to Interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. UMF-302 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. UUF-302 OPERATION Each MMF-302 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports Its type and the status (open/normal/short) of Its Initiating Device Circuit (IDC). A flashing LED indicates that the module Is In communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). 'UUF-302 SPECIFICA TIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 pA (LED flashing). EDL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300 Dual Monitor Module The MDF-300 Dual Monitor Module Is Intended for use in Intel- ligent, two-wire systems. It provides two independent two-wire Initiating device circuits (lDCs) at two separate, consecutive addresses. It Is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides two Class B (Style B) lOG circuits ONLY. Class A (Style 0) lOG circuits are NOT supported in any application. UDF-300 SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Maximum operating current: 750 pA (LED flashing). .. Page 2of6—df-52121:al-04128/08 Maximum iDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32° to 120°F(0°t049°C). Humidity range: 10% to 93% (non-condensing). Dimensions; 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 2.125° (5.398 cm) deep. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address "26", then It will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SM13500 sur- taco-mount box. Mounting hardware and Installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. I.,... H CAUTION O-5NER(3lZE UNIT PRIOR TO SERVICING - -- --- Face plate for MMF-300, MMF-302, and MDF-300 The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S3705 FM Approved CSFM: 7300-0075-185 MEA: 72-01-E Product Line Information MMF-300: Monitor module. MMF-301: Monitor module, miniature. MMF-302: Monitor module, two-wire detectors MDF-300: Monitor module, dual, two independent Class B cir- cuits. SMB&OO: Optional surface-mount backbox. Architects/Engineers' Specifications Specifications of these and all FlreLlte products are available from FireLite. Mounting Diagrams for Standard-sized Modules dl-5212151 • 04128/08 - Page 3 of Wiring Diagrams The following wiring diagrams are included: MDF-300: Typical dual two-wire Style B Initiating device circuit configuration. PJMF-301: Typical two-wire Style B initiating device circuit configuration. MMF-300: Typical two-wire initiating circuit configuration, NFPA Style B. MMF-300: Typical four-wire fault-tolerant initiating circuit configuration. NFPA Style D. MMF-302: Interlace two-wire conventional detectors, NFPA Style B. MP.IF-302: interface two-wire conventional detectors, NFPA Style D. Applications with Conventional Detectors: Resetting Conventional Detectors Figure 1 MDF-300: Typical dual two-wire Style B Initiating device circuit configuration. Two Initiating Device Cinus'ts ,qw, (L&H) TO Next - 230 iA max. 12 VOC max MONITOR + or Previous FROM Pan& Device each power-liiniited to + scat, 47K EOL 0 MODULE Resistor Commur on Line - Twisted-pair is ELR-47K 0 32 VDC mmdmum + recommended. 47K EOL 60 3 Mcen wlrtrg Is supemised and power Reelato, ELR-47 Connect modules to listed cenaIible Fire- 9-1 ANY NUMBER of Ut. Listed contact dos ire detces may be used. DO NOT MIX fire alarm Initiating, supervisory, or secuitty devices on the same circuit. - Install contact closure devices per manufacturer's installation instructions. Figure 2 MMF-301: Typical two-wire Style B Initiating-device circuit configuration. TO 111- NEXT DEVICE UL LISTED BLACK 4RED Compatible Panel 78g 21 14 10 :at 4YELLOW 47KEOL INCLUDED Page 4ot6—dt-52121a1 .04/28108 NOTE: Wiring Diagrams this Page; UUF-300 Connect modules to listed compatible FireLite control • Any number of UL-listed contact closure devices may be panels only. used. All wiring shown is supervised and power limited. • DO NOT MIX tire alarm Initiating and supervisory devices Install contact closure devices per manufacturers' instaila- on the same circuit. tion Instructions. Figure 3 MMF-300: Typical two-wire initiating circuit configuration, NFPA Style B. - FROM Panel xt + or Previous lnWatingDOvice TO DeWce ff Dr , p(D(t Device wer knited: NFPA Circuit (IDC) ComrnunlcaUon Line 32 VDC maximum. 18ted.pait Is + recommended. '" 47K EOt. Resistor Communication Loss ELR-47K (optional connection for panels which support this feature) FUTURE FEATURE Figure 4 MMF-300: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. TO Nexi oew - FROM Panel + orPreos IONITOR Ltemca MODULE (01 Line Communication 0 32 VOC maximum. Twisltod-peir is EOLReeslor I recommended, is internal at termlnais8&9 I on Loss (optional connection for panels 'ehi rt this feature) FUruRrFEATURE dt-52121:al .O4/28A8— Page 5o(6 TO Nest Device NOTE: Wiring Diagrams this Page: UUF-302 and CRF-300 Connect modules to listed compatible control panels only. • Detectors must be UL listed compatible with module. Terminal wiring must be power limited. • Install detectors per manufacturers' installation instructions. DO NOT MIX tire alarm Initiating and supervisory devices • Power to the Interface module must be externally on the same circuit, switched to reset the detectors. An relay control module DO NOT LOOP wire under terminals. Break wire run to can be used to switch power from a standard power sup- provide supervision of connections, p see Figure 8 below. Figure 5 MMF-302: Interface two-wire conventional detectors, NFPA Style B. 3.9K EOL Resistor (included) A2143-1O 7occCjj FROM Panel or Previous Device Communication Line 32 VDC maximum, TwIsted-pair Is recommended. - Listed Battery Backup Ei swItched DC power supply. 0 j ._ Optional Branch Circuit TO Nest Interface Module LI U Module supervises supply voltage and detector loop. Figure 6 MMF-302: Interface two-wire conventional detectors, NFPA Style D. TO FROM Paneli Devise + + o Previous INT!RFACS MODULE Devise Communication Line 32 VDC maximum. Twisted-pair Is recommended. - Listed Battery Backup switched DC power supply. Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. 676W Figure 7 Applications with Conventional Detector: Resetting detectors NOTE: To feset contendIonal detectors, extema yswito'7 DO~ to the Aite,face module they are connected to. This example shows CRF-300 (see DF-52130). FROM ROM Panel- Device + or Previous Device DC POWER-1 SUPPLY HI L!2 I Q Usted for Flra (—) Protection with Communication Line a 32 VDC maximum. Twisted-pair is recommended 7rt Fire-Lite® and UteSpeode are registered trademarks of Honeywell International Inc. 02008 by Honeywell International Inc. NI rights reserved. Unauthorized use of this docs.mient Is strictly prohibited. This document Is not Intended to be used for installation purposes. 12999==Iso 9001 We to keep our product InIorniatIon up-to.date and ________ We cannot cor all spaclflc applications or anticipate d requirements. INNiCIIU AN specifications are subject to change without notice. SillilY SYSTEMS Made In the U.S. A. For more information, contact FhUte Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.11relite.com Page 6of6—dt-521211.04128/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:185 Page 1 of 1 CATEGORY Misc. Devices/Control Unit Accessories LISTEE Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 15-32VDC INSTALLATION: In accordance with liste&s printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed electrically compatible fire alarm control units. Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division COMM Notification Series AS Audible Strobe Appliances and Series AH Audibles SERIES AS SERIES AH Features Approvals Include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ..• ADAINFPA/UFC/ANSI Cpmpilant Wall mount models are available with Field Selectable Candela Settings of 15/30175/110cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15130175195cd or 1151177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce I flash per second over the regulated voltage range 12 and 24 'IDC models with wide UL "Regulated Voltage Range' using filtered DC or unfiltered FWR input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast Installation with IN/OUT screw terminals using #12 to #18 AWG wires Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audiblee offer more features with low current draw. Strobe options for well mount models Include 1575cd or the Wheelock patented MCW multi-candela wag strobes with field selectable candela settings of 15130175/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30175/95cd or the high Intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) Is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM,DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA72) simultaneously for all audible appliances. This ensures a distinct temporal (rode 3) pattern when 2 or more audiblas are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when Installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. For Weatherproof Series AS, See Datasheet S9004 fUL f 9J APPROVW E5848 151.2-E 71260785:131 s53 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed In bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATiONS AND ASSOCIATED IN$U.TION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR ?PLYSIG ThIS PRODUCt VISIT WWW.COOPE4HEEI.00K.O0M OR GON'IAC'T COOPER WHEEL.00K FOR THE CURRENT INSTALLATION INSTRUCTIONS. FALURE 10 COMPLY WITH ANY OP THESE SISTHUC11ONS, CAUTIONS OR WARNINGS COULD RESULT 14 NPPER APPUCATION. INSTAUATION ANDIOR OPERATION OF THESE PRODUCTS INAN EMERGENCY SITUATiON, WHICH COULD RESULT IN PWPERT( DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at I flash per second minimum over their Regulst.d Voltage Range. Note that NFPA-72 specifies a fldsh rate of 1 to 2 flashes per second and ADA Guidelines specify a flesh rate of ito 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a tsnarature range of 32F to 120F (0C to 49C) and maximum humidity of 93% (12%). Series NH horne are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltge Range" Is the newest terminology used by UL. to Identify the voltage range. Pdou to this change UL used the terminology "Usted V91tage Rang.". Table 2; dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA Per UL 464 dBA 10 ft. 10 ft. High 91 99 Continuous MedIum 88 95 Horn Low 83 90 High 87 99 Medium 84 95 Code 3 Horn Low 79 90 Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela (Cd) AS-24MCW 24 16.0-330 1513W75/110 AS-24MCCH 24 18.0-33.0 116/177 AS-241575W 24 16.0-33.0 15(75onAxis) AS-121575W 12 8.0-17.5 15(75onAxis) AS-24MCC 24 16.0-33.0 15130/75/95 AS-24MCWH 24 16.0 -33.0 136/185 ASWP-2475W 24 16.0-33.0 75 @ -31"F Table 3: Average RMS Current Audible I Wall Mount Audible Strobe uodSis 1. Ceiling Mount Audible Strobe Mod&s 24 VDC Models AH-24 AS-241676W 1575od High (99) 24 vdc 0.062 0.100 BA IJL max 0.080 0.121 Mod (95) 24 vdc 0.033 0.080 IJL max 0.043 0.107 dBA Low (90) 24 vdc 0.017 0.072 UL max* 0.021 0.100 dBA Wall Mount Audible Audible 12 VDC Models Strobe AN-12 A3-121676W High (99) 12 We 0.163 0.260 UL max* 0.192 0.320 dBA Mod (95) 12 We 0.07 0.195 UL max* 0.10 0.275 dBA Low (90) 12 vdc 0.039 0.175 UL max 0.058 0.265 dRA A3.24M0W A3-24MCWH AS-24MCC AS-24MCCH 150d 300d 75cd hOed 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.260 0.320 0.088 0.125 0,200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 0.074 0.110 0.190 0.253 0.340 0.465 0.080 &122 0.201 0.269 0.340 0.465 0.062 0.076 0.121 0.158 0.220 0.296 0.066 0.082 0.132 0.173 0.220 0.295 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.1981 0.263 1 0.335 0.460 Table 4: Average Curren? (AMPS) For Series ASWP' Voltage High dBA Setting ($9)dBA Medium dBA Setting (95)dBA Low dBA Setting (90)dBA 24.0 VDC 6.128 0.105 0.098 UL MW 0.188 0.155 0.150 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (1 6-33v for 24v units).. For strobes the UL max current is usually at the minimum listed voltage 06v, for24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation Instructions. Wlrinq Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROND TO NEXTO APPLLANCEO ,PPLThNCED OR EOLRD OR FACPD PRCEDINGO - SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-8CP and PS.12!24-8MP FO -4O — AD OIC Am MM co A"D PD Series PS-12/24-4 SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS-A- NAC CIRCUIT WITh NO AUDIBLE SILENCE FEATURE Specifications and Orderinci Information FLJ AD StobecJ NACC cir"itc co AudibPO EoLRO l,O CitcuttO FE AE LUdthl9 NAC 020 Strobe c Cr ync co Sync PE Strobe MAC C DSM Interconnecting wiring shown. Maximum twenty (20)0 For detail using SM or DSM Sync Module refer to Data Sheet $3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring Informationon the power supplies refer to Installation Instruction, P84682 for PS-24-8101C. SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES #10 Model Number Order Code Strobe d&a Nofl Sync DSM SyncwISM, or 2.4 VDC 12 VDC Wall Mount Mount -PS-24-8MC Ceiling AgencyApprovals Mounting Optionstm — UL - - - S-24MCW-FR 9024 15/30/75/110 X X X - X - A.B,D,EF,G,H,J,N,OR)( X X X X X S-24MCW-FW 9025 15/30/75/110 X X X - X - AB,D,E,F,G,H,J,N,O,R,X X X X X X S-24MCWH-FR 3468 135/185 X X - X - A.B,DEFGH,JN,OR,X X X X X S-24MCWH-FW 3469 135/185 X X X - X - A,B,D,EFGH,JNO,R,X X X X X * AS-241575W-FR 7405 15(75onAxis) X X X - X - A,B,D,E.F,G,H,JN,O,RX X X X X X .S-121575W-FR 7410 15(75onAxis) X X - X X - A.8,DE,F,GH,JNO,R,X X X X X X S-24MCC-FR 3161 16/30/75/95 X X X - - X A.B,DE,F,GH,J,NO,R)( X X X X * S-24MCC-FW 3162 15/30/75/95 X X X X A,8,D,E,FGH,J,NO,R,X X X X X * S-24MCCH-FW 3467 115/171 X X X - - X 6,DE,FG,H,JN,0,R,X X X X X S-2475W-FR' 90121 75 © -31°F X X X - X - 1 1 (see Data Sheet S9004) X X X X X H-24-R 7892 - X X X - X X A,BD,E,F,G,N,J,N,OR,X X X X X X H-24-W 7893 - X X X - X X A,BID,E,F,G,H,JN,O,R)( X X X X X 'J-1-12-R 78911 X X - X X X A,8,D,E,F,G,H,J,N,O,R,X X X X X X J-$-12-W 7894 - X X X X X A.B4O,E,F,G,H,J,N,O,RX X X X X X 24WP-R°° ~_12WP-R" 7418 - X X - X X K XX X X 7415 X X - X X X K X I X I X - X For Weatherproof Series AS/AH specifications see data sheet $9004. PENDING "Refer to Data Sheet 87000 for Mounting Options. Not.: Models are available In ether Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, sp.clflcatlons and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. Notification Coopit Noticionb Wheelock' (CJ SAFEPATW Am ltAetn and Fnninswa RnscfflcetFor,s Thnofication appliances shall ce VrvteeiocK Series AS Auqibie Strobe appliances ano Series An Auaibie appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The SeriesAH Audible shell be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All Inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flasitibe enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at I &W7511 10 or 135/185 candela for wall mount and I 3W755 or 115/177 candela for ceiling mount The selector switch for selecting the candela shall be tamper resistant The 1575 candelai strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization Is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol.. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and SeriesAH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-Inch square, 100mm European type backboxes, ortho SHBB Surface Bckbox. If required, an NATP (Notification Appliance Trlmplate) shall be provided.T . ,. .:.. . All notification appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION YFAP WARRANTY Made in USA sinn As/eli inmi CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING. MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7126-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing Impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing Impaired foflowed by any three alpha/numeric characters Indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -2410CC audible/strobes for the hearing impaired followed by two alpha/numeric characters Indicating lens lettering, orientation and color. These units are intended for calling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character Indicating lettering and pro&ict color. Model ASWP-2475W audible/strobe with Integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mpunted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters Indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix Ware for wall mount only. Refer to the listee's data sheet for detailed produpt desctIptin and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15175cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW. Selectable 15cd, 30cd, 75cd, ll0cd MCC: Selectable l5cd, 30cd, 75cd, 95cd MCW-$: Selectable 135cd, 1 85c MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed Installation instructions, applicable codes and ordinances and In a manner acceptable to the authority having Jurisdiction. Models ASWP-2475W and AS- 24MCW are for well mount only. Models with suffix -Ware for wall mount only. Models with suffix -C are for ceiling mount only. *Rev. 06-13.06 Listing No. 7125-0785:131 Page 2 of 2 MARKING: APPROVAL: NOTE: Llstee's name, model number, electiicaWcandela rating, and UL label, Listed as audible and audible/visual signaling devices suitable for the hearing Impaired when used In conjunction with separately listed electrlcauy compatible fire alarm control units. For Indoor use only except Models AHi2WP.ah0 AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization; Models AS Series must be used with Model SM-12124, SMX-1 2/24, DSM- .12/24 or DSMX-12124 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing Impaired applications. ri Rev. 06-13-06 This listing is based upon technical data submlttedtythe applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make :fl Independent verification of any claims. This listing Is not an endorsement or recommendatlori of the Item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to bstee'i data shook Instali tlon,in*tructlons and/or other. Suitable Information sources. Date Issued: JUNE 4o 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager .• :