HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; FA080062; PermitCity ot Carlsbad Fire Alarm Permit Permit No: FA080062 5781 VAN ALLEN Job Address: WY Permit Type: FALARM Parcel No: 2121304400 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 9/25/2008 Approved: .10/22/2008 Issued: 10/22/2008 Inspector: Project Title: INVITROGEN TI FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: ADT SECURITY SERVICES, INC. 3830 CALLE FORTUNADA SAN DIEGO, CA (858) 654-3224 Owner: GRIFFIN CAPITAL CARLSBAD POINTE INVESTORS L L C C/O INVITROGEN CORPORATION 1600 FARADAY AVE CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 125 0 125 0 INVITROGEN 5781 VAN ALLEN WAY CARLSBAD, CA. 92008 FIRE ALARM T.I. SUBMITTAL S Submitted By: FILE COPY AN 3830 Calle Fortunada . San Diego, CA 92123 (858) 654-3133 Lic. # 707408 Contact: DAVE WELLS g INVITROGEN T.I. FIRE ALARM SUBMITTAL DESCRIPTION MODEL # MANF. CSFM# 1 POWER SUPPLY FCPS-24FS8 FIRELITE 7315-0075:206 2 INPUT MODULE MJvIF-300 FIRE LITE 7300-0075:185 4 HORN/STROBE MULTI-CD WALL AS-24MCW WHEELOCK 7125-0785:131 LOT 14/2 FIRE CABLE ADT/GENESIS 7161-1487:100 0 LOT 18/2 FIRE CABLE ADT/GENESIS 7161-1487:100 0 (2) Flre.uTeeALarms www.flrelfte.com GENERAL The FCPS-24FS8 is a compact, cost-effective, 8-amp re- mote power supply with battery charger. The FCPS-24FS8 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expan- sion (to support ADA requirements and NAC synchroniza- tion) or auxiliary power to support 24-volt system acces- sories. The FCPS-24FS8 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits con- figured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS- 24FS8 also contains a battery charger capable of charg- ing up to 18 Amp Hour batteries. FEATURES UL Listed NAC Synchronization using System Sensor, Wheelock, or Gentex (Commander Series) appliances. Cascadable up to 10 power supplies (four with Gentex) with strobe timing maintained. Operates as a sync follower or a sync generator (default). * See note on reverse side. Contains two, fully-isolated input/control circuits (trig- gered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [stand- alone model). Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300) for alarm activation. Four Class B (Style Y) or four Class (Style Z) (with ZNAC- 4 Module) Notification Appliance Circuits. 8.0 A full load output (3.0 A maximum per circuit) in NAC expander mode (UL 864). 6.0 A continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power supervision relay (A77-716B). In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two. Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power). Power-limiting technology meets power-limiting require- ments. Normally-closed trouble contact. Fully supervised power supply, battery and Notification July 8, 2004 DF-52310 • 0-050 FCPS-24F58 24 Volt, 8 Amp Remote Power Supply Section: Power Supplies/Accessories California zzS (.')State Fire Marshal APPROVED 7315-0075:206 LISTED S2424 MEA 219-02-E Appliance Circuits. Selectable earth fault detection. AC trouble report selectable for immediate or 8 hour delay. Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notifica- tion circuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. Battery charger may be disabled via dip switch for appli- cations requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm') wire. Fire-Lite® Alarms is a Honeywell company. This document Is not intended to be used for Installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. I am For more Information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. LNWEE1IFIMRNUMg1uIIM Phone: (800) 627-3473, Toil-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52310 • 07/08/04 - Page 1 of 2 STANDARDS and CODES The FCPS-24FS8 complies with the following standards: NFPA 77 Ntirrl Fira Alarm (",nrtc+ IJL 864 Stnrird for Control Units for Fire Alarm Svs- tems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems (stand-alone mode). SPECIFICATIONS Primary (AC) Power FCPS-24FS8: 120 VAC 60 Hz, 3.2 A maximum. Wire size: minimum 14 AWG (2.0 mma) with 600V insu- lation. Control input Circuit Trigger Input Voltage: 9.0 to 32 VDC. Trigger Current: 2.0 mA (16-32 V). (per input) 1,0 mA (9- 16 V). Trouble Contact Rating 5.0Aat24VDC, Auxiliary Power Output Specific Application Power - 500 mA maximun. Output Circuits +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. 6.0 A maximum total continuous current for all outputs (Stand-alone mode). 8.0 A maximum total short-term current for all outputs (NAC Expander mode). Secondary Power (Battery) Charging Circuit Supports lead-acid batteries only. Float Charge Voltage: 27.6VDC. Maximum Charge Current: 1.5 A. Maximum Battery Capacity: 18 AH. ORDERING INFORMATION FCPS-24FS8 Remote charger power supply (120 VAC). Includes main printed circuit board. transformers, red enclosure, and installation instructions. FCPS-2456RB Replacement mother board. PN 90286 FCPS-24FS Module Mounting Kit ZNAC-4 Class A (Style Z) NAC option module. A77-716B 12/24 VDC end-of-line relay for monitoring 4-wire smoke detector power. BAT-1270 Battery, 12 volt, 7.0 AH (two required). APPLICATIONS Example I Expand notification appliance power an additional 8.0 amps. Use up to 4 Class B (Style Y) outputs or 4 Class A (Style Z) using the ZNAC-4. In this example, the FACP notification appliance circuits will activate the FCPS-24FS8 when reverse polarity activa- tion occurs. Trouble conditions on the FCPS-24FS8 are sensed by the FACP throughthe Notification Appliance circuit. Pane 2 of 2 - DF-52310 • 07/08/04 Example 2 Use the FCPS-24FS8 to expand auxiliary regulated 24 volt system power up to 6.0 amps. Both non-resettable and resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS-24FS8 inputs. Example 3 Use addressable control modules to activate the FCPS- 24FS8 versus the FACP Notification Appliance Circuits, This typically allows for mounting the FCPS-24FS8 at greater distances* away from the FACP while expanding system architecture in various applications. In this example, an addressable control module is used to activate the FCPS-24FS8 and an addressable monitor module is used to sense FCPS-24FS8 trouble conditions. Local auxiliary power output from the FCPS-24FS8 pro- vides power to the addressable control module. Flre'Lltes MS-9200 (198-point), MS-92001.10, or MS-9600 (636- point) addressable FACPs have the capaoility of locating control and monitor modules up to 10,000 feet (3048 m)away. Sync Follower/Generator Note: In some installations, it is necessary to synchronize the flash timing of all strobes in thesystem for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power, which are created by a Fire Alarm Control Panel such as the Fire-Lite MS-9600. When installed at the end of a MS-9600 NAG wire run, this power supply can track (i.e., "follow") the strobe synchronization timing pulses on the existing NAG wire run. This maintains the overall sys- tem flash timing of the additional strobes attached to this power supply. When this power supply is configured (via DIP switch settings) as a "sync follower," this supply's NAC outputs track the strobe synchronization pulses present at this supply's sync input terminal. The pulses are originated from an upstream FACP or other power supply. When this power supply is configured (via DIP switch settings) as a "sync generator," this supply's sync input terminal are not used. Rather, this power supply is the originator of the strobe synchronization pulses on this power supply's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. CALIFORNIA DEPARIMENT OF FORIRY & FIRE PROTECTION t§ OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIAlS LiSTING PROGRAM LISTING SERVICE LISTING No. 7315-0075:206 Page 1 of 1 CATEGORY: Power Units LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models FCPS-24FS6 and FCPS-24FS8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. is alarm Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. Rev. 05-06-05JW This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division df-52121:al • E-325 MM F-300(A) Series! MDF-300 Addressable Monitor Modules General Four different monitor modules are available for Flre'Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 Is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact Input devices. MMF-301 is a miniature monitor module (a mere 1.3° (3.302 cm) H x 2.75° (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device It monitors. MMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit MDF400 Is a standard-sized dual monitor module used to monitor and supervise two Independent two-wire Style B (Class B) dry-contact Initiating device circuits (iDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LfteSpeedTu Is a communication protocol developed by flreLite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new Information, the panel CPU / stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF-300 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module Is intended for use in Intelligent, two-wire systems, where the individual address of each mod- ule is selected using the built-In rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (lDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel.controlied LED indicator. The MMF-300 can be used to replace M300 modules In existing systems. nreuearms by Honeywell o 0 5 a MMF-300 and MMF-302 732. __ a 4_ 9 5 0 detail of MDF-300 - note "ones" addresses are 0, 2, II17 2).3 2 4,6,8only jo i 3 I 1s s ' A) initiating Device Circuit A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit MMF-300 OPERA 770N Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports Its type and the status (open/normal/short) of its Initiating Device Circuit (lDC). A flashing LED indicates that the module Is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). UMF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 100% to 93% noncondensing. Dimensions; 4.5 (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.3W cm) deep box. O UMF-300 APPLICA liONS MMF-301 Mini Monitor Module Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- • Built-In type Identification automatically identifies this device open dry-contact alarm activation devices. May also be used as a monitor module to the panel. to monitor normally-open supervisory devices with special • Powered directly by two-wire FACP. No additional power supervisory indication at the control panel. Monitored circuit required. may be wired as an NFPA We B (Class B) or Style D (Class dt-52121:al • 04/28/08 - Page 1 of 6 High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels. 01 -99 on other compatible systems. 14150.L1 ADDRESS TENS ONES The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit Its small size and light weight allow It to be Installed without rigid mount- ing. The MMF-301 is intended for use in Intelligent, two-wire systems where the individual address of each module Is selected using rotary switches. It provides a two-wire Initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules In exist- ing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, watertlow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory Indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301 OPERATION Each MMF-301 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). MUF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65 (1.651 cm) deep. Wire length: 6' (15.24 cm) minimum. MMF-302 Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFl) immunity. O Page 2of6—df-52121:al .04/28/08 SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. UMF402 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). install ELR across terminals 8 and 9 for Style D application. UMF402 OPERATION Each MMF-302 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). 'MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 pA (LED flashing). EOL. resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current 90 mA per module maximum. Temperature range; 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF..300 Dual Monitor Module The MDF-300 Dual Monitor Module Is Intended for use In Intel- ligent, two-wire systems. It provides two independent two-wire Initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides Mv Class B (Style B) lOG circuits ONLY. Class A (61)48 0) lOG circuits are NOT supported in any application. UDF400 SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Maximum operating current: 750 pA (LED flashing). S Mounting Diagrams for Standard-sized Modules S Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensIng). Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns Itself to two addressable points, starting with the original address. For example, it the MDF-300 Is set to address "26", then It will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 8, or only Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. 4& CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and Installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections Inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency. Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: 82424 ULC: S3705 FM Approved CSFM: 7300-0075-185 MEA: 72-01-E Product Line Information UMF-300: Monitor module. MMF-301: Monitor module, miniature. MMF-302: Monitor module, two-wire detectors MDF-300: Monitor module, dual, two independent Class B cir- cuits. SMBSOO: Optional surface-mount backbox. Architects'/Engineers' Specifications Specifications of these and all FireLite products are available ftom FireLite. dt-52121 a1 • 04/28108 - Page 3 of 6 Wiring Diagrams The following wiring diagrams are included: . 1. MDF-300: Typical dual two-wire Style B Initiating device circuit configuration. IJMF-301: Typical two-wire Style B initiating device circuit configuration. MMF-300: Typical two-wire Initiating circuit configuration, NFPA Style B. MMF-300: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. MMF-302: interface two-wire conventional detectors. NFPA Style B. MMF-302: Interface two-wire conventional detectors, NFPA Style D. Applications with Conventional Detectors: Resetting Conventional Detectors Figure 1 MDF-300: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits (L&H) TO Next each power-limited to Device FROM Panel 230 pA max. 12 VDC max. MONITOR Device Communication or Previous. 47K EOL nication Line Resistor 32 VDC maximum. Twisted-pair is H MODULE recommended. ELR-47K 0 47K EOL All shown wiring Is supervised and povwr Resistor 5, 4 limited. ELR-47 Connect modules to listed compatible Fire- Lite control panels only. Lj ANY NUMBER of UL Listed contact closure devices may be used. - DO NOT MIX lire alarm Initiating, supervisory, or security devices on the same circuit. * Install contact closure devices per manufacturer's installation instructions. Figure 2 MMF-301: Typical two-wire Style B lnitlatingdevlce circuit configuration. N TO 0- NEXT --- Panel -:I] E [ UL LISTED Compatible Control J Bflff4RED 1o1l4 ) c .WOLEThJ [YELLOW 47K EOL INCLUDED 7are*t.y.,r ( Page 4016— df-52121 :al • 04/28/08 - NOTE: Wiring Diagrams this Page: UUF-300 Connect modules to listed compatible FireLite control Any number of UL-listed contact closure devices may be panels only. : used. All wiring shown is supervised and power limited. DO NOT MIX fire alarm Initiating and supervisory devices . • Install contact closure devices per manufacturers' Instaila- on the same circuit. tlon Instructions. Figure 3 MMF-300: Typical two-wire Initiating circuit configuration, NFPA Style B. Device + - FROM Panel Inhliating Device CircuitTONeatONffOR (+) or Previous Device (IDC) MODULE b" NFPA Style 8 power limited; Communication Line 32 VDC maximum.Ilelsied-pair is !bo' + recommended 47K E01 Resistor ELR-47K Communication Loss (optional connection for panels LLJ which support this feature) FUTURE FEATURE Figure 4 MMF-300: Typical four-wire fault-tolerant Initiating circuit configuration, NFPA Style D. TO Next - FROM Pane! + or Previous De; MONITOR Device MODULE Communication Line 32 VDC maximum. LI j000th Twisted-pair is recommended EOL Resretor , is internal at termInals 8 &9 5, 4 Communication Loss (optional connection for panels c ature) FUrURrFEArunE . -- - df-52121 :al NOTE: Wiring Diagrams this Page: MMF-302 and CRF-300 Connect modules to listed compatible control panels only. • Detectors must be UL listed compatible with module. Terminal wiring must be power limited. • Install detectors per manufacturers' installation instructions. • DO NOT MIX tire alarm Initiating and supervisory devices • Power to the Interface module must be externally on the same circuit, switched to reset the detectors. An relay control module DO NOT LOOP wire under terminals. Break wire run to can be used to switch power from a standard power sup- provide supervision of connections, ply; see Figure 8 below. Figure 5 MMF-302: Interface two-wire conventional detectors, NFPA Style B. or Previous TO Next FROM Pane! Device + ct PITERFACE Device MODULE "— communication Line 32 VDC maximum. Twisted-pair Is recommended. 3.9K EOL +Tisted Battery Backup Resistor switched DC power supply. (included) A2143.10 optional Drench circuit Module supeMess supply TO Next Interface Module voltage and dotoctor loop. e72e0s.w Figure 6 MMF-302: Interface two-wire conventional detectors, NFPA Style D. :lu - FROM Pane! + or Previous Device E WTERFACE Communication Line 32 VOC maximum, Twisted-pafr is recommended. Optional Drench Circuit C—) Listed Battery Dackup + switched DC power supply. TO Next Interface Module Module supereises supply voltage and detector loop. 67&wi5 Figure 7 Applications with Conventional DetectorS: Resetting detectors NOTE: To reset conventional detectors extematy witch off powsr to the Inte,face module they are connected to. The example shows CRF-300 (see OF-52130). FROM Panel TO Next QQx - or Previous Device + Device ö 'j' DC P OWER MOOULE SUP Liste "Communica1lon Line Prot 32 'JOG maxunum. Battery Backup 81 12 Twisted-pa recommend ore AOrWcSa i . Flre.Ute5 and UteSpeed® are registered trademarks of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. - --U. This document Is not Intended to be used for Installation purposes. 159999— -9 ISO 9001 We fly to keep our product Information up-to-date and accurate. _________ mui We Gannet cover al specific applications or anticipate all requirements. ll1 III1W AU specifications are subject to change vithout notice. IUIIITY SYSTEMS . Made lnthe U.S. A. For more information, contact FireLfte Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.ftretite.com Page 6 of 6 —dl-52121:al - Page 1 of I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIAlS LISTING PROGRAM O LISTING SERVICE LISTING No. 7300-0075:185 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models MDF-300, MMF-301 MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division UtNUUIlLIOF1 Series AS Audible Strobe Appliances and Series AH Audibles Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibies offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/I85cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high Intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) Is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM,DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Prçtocol, synchronization of the continuous horn tone provides the temporal (code 3)tone (mandated by NFPA72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when Installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achrved by using only 2 wire. Features Approvals InclUde: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information .• ADA/NFPA/UFC/ANSI Cpmpliant Walt mount models are available with Field Selectable Candela Settings of 15/O/75/110cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/1 77cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99. 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce I flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range' using filtered DC or unfiltered FWR input voltage Synchronize Using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast Installation with IN/OUT screw terminals using #12 to #18 AWG wires For Weatherproof Series AS, See Datasheef S9004 1caTy MEA APNM E5046 151-52-E 7125-0785:131 s53 24 VDC Models AH-24\ AS-24157W 1575cd High (99) 24 We 0.062 0.100 dBA UI. max* 0.080 Mod (95) 24 vdc 0.033 UL max° 0.043 0.107 dBA Low (90) 24 We 0.017 0.072 UL max- 0.021 0.100 dBA Wall Mount Audible Audible 12 VDC Models Strobe AM-12 AS-121575W High (99) 12 vdc. 0.163 0.260 UL max- 0.192 0.320 d8A Mod (95) 12 vdc 0.076 0.195 UL max O.Ioq 0.275 dBA Low (90) 12 vdc 0.039 0.175 UL max* 0.058 0.265 dBA 0 NOTE All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are Printed In bold capital letters A WARNING: PLEASE READ THESE SPECiFICATIONS AND ASSOCIATED IN$TALL.,A11ON INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYING THIS PRODUCT VISIT WWW.COOPErnVHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTAU.AIION INSTRUCTIONS. FALURE 10 COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN U1PPERAPPUCA11ON, INSTAlLATION AND/Olt OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU ANDIOROTHER& S3 eneral Notes.- Strobes are designed to flash at I flash per second minImum over their 'Regulated Voltage Range. Note that NFPA-72 specifies a fldsh rate of 1 to 2 flashes per second and ADAGuldoIlnes specify a flash rats oil to S flashes per second. All candela ratings represent minimum effective StrObe Intensity based on UI. Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for Indoor use with. temperature range of 32F to 120F (0°C to 49C) and maximum humidity of 93% (12%). Series NH home are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voitge Range" lathe newest terminology used by UL to Identify the voltage range. Prior to this change UL used the terminology "Usted V9ltage Range". Table 2; dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA Per UL 454 dBA l0 ft High 91 99 Continuous Medium 88 95 Horn Low 83 96 High 87 99 Medium 84 95 Code '3 Horn Low 79 90 Table 1: Ratings Per UL 1911 Model Number be Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela Cd AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15 (75 on Axis) AS-121575W 12 8.0-17.5 15(75onAxis) AS-24MCC 24 16.0-33.0 15130175/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0-33.0 75 @ -31°F Table 3: Average RMS Current ill Mount Audible Strobe Modls Ceiling Mount Audible Strobe Mo4ls AS-24M0W AS-24MCWH AS-24MCC AS.24MCCH 15cd 30cd 75cd - 110cd 15cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 20 --- 0.102 0.'125 0.150 0160 0.320 0.088 0.114 0.166 0.205 0.256 0.320 0.200 O7 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 0.074 - 0.110 0.190 0.253 - 0.340 - 0.465 - 0.080 - 6.122 - 0.201 0.269 0,340 0.465 0.052 - 0.976 - 0.121 0.158 - 0.220 - 0.295 - 0.056 - 0.082 0.132 1 0.173 1 0.220 0.296 0.068 0.105 0.182 0.245 0.335 0,460 0.074 0.113 0.198 0.263 1 0.335 1 0.460 Table 4: Average Current* (AMPS) For SerieS ASWP' Voltage High dBA Selling (99)dBA Medium dBA Setting (95)dBA Low dBA Setting (90) dBA 24.0 VDC 6.128 0.105 0.098 UL Mae 0.168 0.155 0.150 RMS current ratings are per UL average RMS method. UL max current rating Is the maximum RMS currentwithin the listed voltage range (18-33v for 24v Units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v unite). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see Installation Instructions. Wiring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROND PRECEDING[] TO NEXTO t,PPLLANCEO APPLIPiNCED OR EOLRD OR FACPD SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-I V24-8CP and PS-I 2/24-8MP aJTEumO FD 1-40 _!rc 4-.CLASa AO ORO CD 2-CLA3 P8-12/24.8 L... SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAG CIRCUIT WITh NO AUDIBLE SILENCE FEATURE Specifications and Orderinri Information FtJ -0 +0STROB90 -0SflOBE0 AD St robeD mm ait co 4eu4tb aD PD '80180 MdibleO -flucu. b aD CircuitU FO 'Audible øD AD NAC C Strobe NAC C CD Audible MAC PD Mi40 Sync Strobe NAC C DSM Interconnecting wiring shown. Maximum twenty (20)0 For detail using SM or DSM Sync Module refer to Data Sheet $3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-81VIC. SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES - -,(SM #10 Model Number Order Code Strobe Candela Non- Sync Sync wISM, 24 VDC or 12 VDC ICellinDSM Wall Mount Mount Mounting OpUons° Agency Approvals - - - - S-24MCW-FR 9024 15/30/75/110 X X X - X - AB,D,E,F,G,H,J,N,O,R,X X X X X X S-24MCW-FW 9025 15/30/75/110 X X X - X - A,B,D,E,F,G,H,J,N,O,R)( X X X X X S-241VICWH-FR 3468 1 135/185 X X - X - B,D,E,FGH,J,NO,R,X X X X X * lS-24MCWH-FW 3469 135/185 X X X - X - A8,D,E.FG,H,J,N,O,R,X X X X X * S-241575W-FR 7405 115 (75 on Axis) X X X - X - A,B,D,E,F,G,H,J,N,o,R)( X X X X X S-I21575W-FR 7410 115(75 on Axis) X X X X - A,B,D,E,F,G,H,JN,O,R,X X X X X X ¼S-24MCC-FR 3161 15/30/75/95 X X X - X A,B,D,E,F,G,H,JN,O,R,X X X X X * S-24MCC-FW 3162 15/30/75/95 X X X - - X A,B,DE,F,G,H,JN,O,R,X X X X X * S-24MCC11-FW 34671 115/177 X X X - - X A,8,D,E,F,G,H,J,N,O,R,X X X X X * M'-2475W-FR°° 9012 75© -31°F X X X • X -I (see Data Sheet S9004) X X X X X 7892 - X X X - X X B,D,EFG,H,J,N,O,R,X X X X X X -24-W I H 7893 - X X X - X X A,B,D,E,FG,H,J,N,O,RX X X X X X -12-R 7891 -X X - X X X A,B,D,E,FG,H,J,N,o,R,x X X X X X -12-W 7894 -X X - X X X A,B,D,E,FG,H,J,N,O,Rx X X X X X -24WP-R°° 7416 - X X - X X K X X X X H12WPR** 7415 - X X - XXX K X X X uu. ruuu-1 epuelIuun5 aee ta aneei *PENDING ***Refer to Data Sheet 87000 for Mounting Options. Note: Models are available In ether Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change wIthout notice In accordance with Wheelock Inc. standard terms and conditions. Notification Arnhftpft and Phrtinaam Qnacfflcetlos The notification appuances shall be vvrieeiock Series AS Audible Strobe appliances and Series Al-i AuaiDie appliances or approved equals. The SenesAS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The SerlesAH Audible shall be LIL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) IThe audible portion of the appliance shall have a minimum Otthree (3) field selectable sethngs for dBA levels and shall have a choice f continuous or temporal (code 3) audible outputs. he strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and hall incorporate a Xenon fiasibbe enclosed In a rugged Lexan® lens. The Series AS shall be of low current design. Wnere Multi- andela appliances are specified, the strobe intensity shall have field selectable sethngs and shall be rated per UL Standard 1971 at 5/3W751110 or 135/185 candela for wall mount and 15/3W755 or 115/177 candela for ceiling mount The selector switch for selecting the candela shall be tamper resistant The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance) When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply falls to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Bckbox. If required, an NATP (Notification Appliance Trimplato) shall be provided. All notification appliances shall be backward compatible. 0 "I- WE ENCOURAGE AND SUPPORT NICET CERTIFICATION YFARWARRAPJTY : Made inUSA 1' • ciinn AS. ;awinmi CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, ?121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters Indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only.,,, Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product coior. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character Indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mpunted to Model WPBB back box. Models AS-24MCVVH and AS-24MCCH audible/strobes for the hearing Impaired followed by two alpha/numeric characters Indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix Ware for wall mount only. Refer to the listee's data sheet for detailed produpt desctlptiqn and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15175cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:ll0cd MCW. Selectable l5cd, 30cd, 75cd, 110cd MCC: Selectable l5cd, 30cd, 75cd, 95cd MCW-I: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -Ware for Wall mount only. Models with suffix -C are for ceiling mount only. . •Rev. 08-13-06 S S Listing No. 7125-0785:131 Page 2 of 2 MARKING: Ljstee's name, model number, electrical/candela rating, and UL label. APPROVAL: listed as audible and audible/visual signaling devices suitable for the hearing impaired when used In conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 Or DSMX-12I4 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation InStruction Manual for details.' These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models ASWP-2475W, AH-12, Al-l-24, -I2WP and -24WP audible devices are not suitable for the hearing Impaired applications. *Rev. 08-13-06 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing is not an endorsement or recommendatiori of the item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listeo'§ data sheet, Installation Instructions and/or other Suitable Inform urces. Date Issued: JUNE 4 2007 Listing E ires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marsha! 17¼ Program Manager \ V V V S5 5 5 •5 'V DF-52395:A • Al -90 MS-9600 Rev. 2/DACT-UD: Intelligent Address- able FACP with Optional 2nd Loop (2) FlreLITeALarms by Honeywell AWireaffi11 Etrirt i The Fire.Lite MS-9600 is a compact, cost-effective, intelligent addressable fire alarm control panel with a capacity of 318 addressable FiresLite devices on one Signaling Line Circuit (SLC) or a total of 636 addressable points with an optional second loop (SLC-2). An optional modem (DACT-UD) is avail- able for remote site upload/download and/or remote monitor- ing. Each Signaling Line Circuit (SLC) loop supports up to 159 '"- addressable detectors including photoelectric, photoelectric I with heat, ionization, photoelectric duct, fixed heat, fixed heat) with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), con- trol (for Notification Appliance Circuits), and relay (two Form- C) modules. The panel uses surface-mount technology and is designed for ease of installation, programming, and mainte- nance. It features the latest in advanced fire protection tech- nology, including maintenance alert and automatic detector test functions. SPECIAL FEATURES: Optional modem. Selectable strobe synchronization per NAC. Remote site upload/download. Four Class B or two Class A NAC circuits. FEATURES SLC Loop: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 318 addressable devices per loop (159 detectors and 159 monitor, control, or relay modules), including the new addressable dual-monitor module, heat detectors, and duct detector. SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG (3.31 mm2). Requires twisted, shielded wire (3,000 ft./914.4 m untwisted, unshielded wire). Notification Appliance Circuits (NACs): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. Advanced Fire Technology: Sensitivity testing with printable results, onsite or offsite. Automatic drift compensation. Programming and Software: • Autoprogram (learn mode) reduces installation time. Fully programmable from local keypad, local PS-2 keyboard or PC via PK-Plus Windows® utility. Remote site upload/download capability (with DACT-UD). Two-level user-programmable passwords. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 99 software zones. User Interface: Optional modem (DACT-UD). Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules, ACS Series annunciators or LCD- 80F remote annunciator. EIA-232 printer/PC interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjustments. History file with 1,000-event capacity. EIA-485 supporting up to 32 ACS Series annunciators. EIA-485 supporting up to 32 LCD-80F annunciators. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Local piezo sounder. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). DF-52395:A • 11/26/07 - Page 1 of 6 WIRING REQUIREMENTS The SLC requires use of a specific wire type to ensure proper circuit operation. It is recommended that all SLC wiring be twisted-pair shielded to minimize the effects of electrical inter- ference. Wire size should be no smaller than 18 AWG (0.821 mm2) and no larger than 12 AWG (3.31 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. Wire Requirements Distance in Feet (m) Typical Wire Size Twisted-pair, shielded 10,000 feet 12 AWG (3.31 mm2): Belden 9583, Genesis (3,048 m) 4410, Signal 98230, WPW 0999. Twisted-pair, shielded 8,000 feet 14 AWG (2.08 mm2): Belden 9581, Genesis (2,438 m) 4408, Signal 98430, WPW D995. Twisted-pair, shielded 4,875 feet 16 AWG (1.31 mm2): Belden 9575, Genesis (1,486 m) 4406 and 4606, Signal 98630, WPW D991. Twisted-pair, shielded 3,225 feet 18 AWG (0.821 mm2): Belden 9574, Genesis (983 m) 4402 and 4602, Signal 98300, WPW D975. Untwisted, unshielded 3,000 feet (915 m) 12— 18 AWG (3.31 - 0.821 mm2). 24 VDC EIA -485 INTERFACE (DIM-485) built into the motherboard (four wires) Optional DACT-UD DACTUD for Central Station reporting and remote upload/download (see photo detail below) LCD-80F Up to 6,000 ft. (1825.8 m) between each LCD-80F in the ElA-485 loop, and between each LCD-80F and the FACP 24 VDC I P .1 p1 EIA -485 iiiiI in ACS mode F—ii-1I-i-1I (two wires) ANNUNCIATORS LDM, ACS/ACM EIA -232 INTERFACE (PIM-24) built into the motherboard : &aamift-vw 111 - IH Optional REVERSE POLARITY! CITY BOX OUTPUT (4XTMF) 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8RF) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES -4. I i SMOKE DETECTORS 5D355, SD355T, CP355 HEAT DETECTORS H355, H355R DUCT DETECTORS D350PL, D35ORPL x 0 00 MONITOR MMF-300, MDF-300, MMF-302, CMF-300, CRF-300, 300 MINI MONITOR MMF-301 ADDRESSABLE MULTI-MODULES MMF-300-1 0, MMF-302-6, CMF-300-6, CRF-300-6 PULL STATION BG-1 2LX 52395d1.wmf Optional 4XTMF module (conventional reverse polarity/city box transmitter). Page 2 of 6— DF-52395:A • 11/26/07 Controls and Indicators LED INDICATORS 1 AC POWER (green) 2 FIRE ALARM (red) 3 SUPERVISORY (yellow) 4 ALARM SILENCED (yellow) 5 TROUBLE (yellow) 6 MAINTENANCE/PRESIGNAL (yellow) 7 DISABLED (yellow) 8 BATTERY (yellow) 9 GROUND (yellow) MEMBRANE SWITCH CONTROLS 1 ACKNOWLEDGE/STEP 2 ALARM SILENCE 3 DRILL 4 RESET (lamp test) 5-16 12-key pad with full alphabet 17-20 4 cursor keys 21 ENTER Field-Programming Features OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order pro- gramming kit PlC-CD, containing PK-Plus, separately). Upload/ download system programming locally to the MS-9600 in less than one minute. AUTOPROGRAMMING: Command the MS-9600 to program itself (takes less than 30 seconds). In the Auto-Program mode, the MS-9600 scans for all possible devices at all addresses, stores the device types, and addresses found, and then loads default values for all options (General Alarm). It also checks for two or more devices set to the same address. ONLINE EDIT: While still providing fire protection, the MS- 9600 may be programmed from the front panel. Simple menu trees displayed on the LCD allow the trained user to perform all functions without referring back to the programming man- ual. ENGLISH LABEL LIBRARY: Quickly select labels from a standard library of more than 50 adjectives/nouns, such as "FLR 3 HALLWAY," or enter custom labels letter-by-letter. Use recall function to repeat previously used label. PROGRAM CHECK: Automatically catch common errors, such as control modules not linked to any zone or input point. Maintenance Alert The MS-9600 continuously monitors each smoke detector and is capable of reporting maintenance conditions. This reduces the risk of false alarms due to dust accumulation. Refer to the control panel installation manual for more information. Automatic Test Operation The MS-9600 performs an automatic test of each detector every two hours. Failure to meet the test limits causes an AUTO TEST FAIL trouble type. System Reset clears this trou- ble. Specifications AC Power - TB1: 120 VAC, 60 Hz, 3.0 A. Wire size: minimum 14 AWG (2.08 mm2) with 600 V insulation. Battery (lead acid only) - TB2: Maximum charging circuit: Normal flat charge 27.6 VDC @ 1.0 A. Maximum battery charger capacity: 25 AH. MS-9600 cabinet holds maximum of two 18 AH batteries. For 25— 120 AH batteries, use the CHG- 120F or CHG-75 Battery Charger and BB-55F Battery Box. NOTE: Jumper JP3, on the FACP main circuit board, must be cut to disable the FACP battery charger when using the CHG- 120E Communication Loop - (standard) TB8: 24 VDC nominal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) total twisted, shielded pair length. Maximum loop current: 400 mA (short circuit) or 100 mA (normal). Maximum loop resis- tance: 40 ohms. Supervised and power-limited. The maximum available current shared between all NACs and auxiliary power outputs is 7.0 A at 24 VDC. Notification Appliance Circuits - TB4: Power-limited cir- cuitry. Maximum voltage drop in wiring: 2.0 VDC. Nominal operating voltage: 24 VDC. Current limit: fuseless, electronic, power-limited circuitry. Maximum signaling current per circuit: 3.0 A. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for NACs. Refer to Fire-Lite Device Compatibility Docu- ment for listed compatible devices. Programmable and Trouble Output Relays - TB5: Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) - TB3, Terminals 1(+) & 2(—): Maximum ripple volt- age: 10 mVrms. Up to 3.0 A for powering four-wire smoke detectors. Power-limited circuit. Refer to Fire-Lite Device Com- patibility Document for listed compatible devices. Nonresettable Power #1 (24 VDC Nominal) —TB3, Termi- nals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVrms. Up to 0.5 A total DC current available from each output. Power-lim- ited circuit. TB3, Terminals 5 (+) & 6 (-): non-resettable power #2. ElA-485 (ACS) - T136: ACS annunciator connector, Terminal 1 (+) and Terminal 2 (-). EIA-485 (TERM) - TB7: Terminal mode annunciator connec- tor, Terminal 1 (Out +), 2 (In +), 3 (Out —), 4 (In -). EIA-232 - TB8: PC/printer connector, Terminal 1 (Transmit), 2 (Receive), 3 (DTR), 4 (Ground). Cabinet Specifications Door: 18.67" (47.43 cm) high x 15.78" (40.08 cm) wide x 1.08" (2.74 cm) deep. Backbox: 18.50" (47.0 cm) high x 15.50" (39.37 cm) wide x 4.37' (11.1 cm) deep. Trim Ring (FC-TR): 21.62" (54.92 cm) high x 18.62" (47.3 cm) wide. Product Line Information MS-9600: 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed circuit board, and cabinet. DACT-LID: Optional modem for remote site upload/download and/or remote monitoring. ACM-8RF: Optional plug-in relay module provides 8 Form-C 5.0 amp relays. PK-CD: Contains PK-Plus programming software for Win- dows®-based PC computer (cable not included). SLC-2: Optional expander module, enables second SLC loop DF-52395:A • 11/26/07 — Page 3 of 6 BRKT-9600: Bracket, mounts UDACT-F and ACM-8RF within 1300: This module isolates the SLC loop from short circuit con- MS-9600 cabinet. ditions (required for Style 7 operation). DP-9600: Dress panel for MS-9600. FC-TR: Trim Ring for semi-flush mounting. BB-55F: Battery box, required to house two 25 AH batteries and one CHG-120F battery charger. For batteries greater than 25 AH, consult factory for housing/mounting arrange- ments. BB-26: Battery backbox, holds up to two 25 AH batteries. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 25 to 120 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. BAT Series: Batteries, see data sheet DF-52397. PRT/PK-CABLE: Cable printer/personal computer interface cable. Compatible Addressable Devices All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (B350LP base included). D350PL: Photoelectric low-flow duct smoke detector. D350RPL: Photoelectric low-flow duct smoke detector with relay option. MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0' (10.16 cm) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult Device Compatibility Document for compatible smoke detectors. CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0' (10.16 cm) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6E MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-617. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-617. NOTES: 1) Compatible with legacy FiresLite 300 Series devices. Please consult factory for further information on previ- ous 300 Series devices: CP300/CP350, SD300(T)/5D350(T), D350(R)P, M300, M301, M302, C304, and BG-10LX. 2) "A" suffix should be included only when ordering ULC listed units (e.g., 5D355A, MMF-300A). 3) For more information on Com- patible Addressable Devices for use with the MS-9600, see the following data sheets (document numbers): AD355 (DF-52386), BG-1 2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), D350PLJD35ORPL (DF-52398), H355 Series (DF-52385), 1300 (DF-52389), MMF-300 SerieslMDF- 300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF- 52356), SD355/SD355T (DF-52384). Compatible Annunciators EIA-485 interface: Built into the motherboard. ACS/ACM Annunciator Series: Allows annunciation of loop modules and detectors. For more information, refer to data sheet DF-52378. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. For more information, refer to data sheet DF-51384. LCD-80F (Liquid Crystal Display) point annunciator: 80- character, backlit LCD-type fire annunciators capable of dis- playing English-language text. Up to 32 LCD-80F annunciators may be connected to the ElA-485 terminal mode serial inter- face on the MS-9600 motherboard. For more information, refer to data sheet DF-521 85. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH(non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F. Page 4 of 6— DF-52395:A • 11/26/07 NFPA Standards The MS-9600 complies with the following NFPA 72 Fire Alarm Systems requirements: LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). REMOTE STATION (Automatic, Manual and Waterflow) (requires 4XTMF). PROPRIETARY (Automatic, Manual and Waterflow). CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). Agency Listings and Approvals The listings and approvals below apply to the basic MS-9600 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL: S624 ULC CS68 (except DACT-UD) FM approved CSFM 7165-0075:191 MEA 72-01-E/341-03-E DF-52395:A • 11/26/07 -Page 5 of 6 Fire-Lite Alarms® is a registered trademark of Honeywell International Inc. Windows® is a registered trademark of Microsoft Corporation. ©2007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINEEKIN & MMVFC1R1N& All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6 of 6— DF-52395:A • 11/26/07