Loading...
HomeMy WebLinkAbout5808 VAN ALLEN WAY; ; AS140273; PermitCity ot Carlsbad Sprinkler Permit Permit No: AS140273 5808 VAN ALLEN Job Address: WY Permit Type: SPRINK Parcel No: 2121205600 Lot #: 0 Status: ISSUED Applied 10/23/2014 Approved: 11/4/2014 Reference No.: Issued: 11/4/2014 PC #: Inspector: Project Title: JOSE TACOS INSTALL NEW RECESSED STANDARD SPRAY PENDENT FROM EXISTING 1" OUTLET AT LOCATION ON PLANS, Applicant: TOTAL FIRE PROTECTION, INC STE. 244 1611-A S. MELROSE DR. VISTA, CA 760-525-4329 Owner: BERDAN HOLDINGS L L C C/O BLT ENTERPRISES 501 SPECTRUM CIR OXNARD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 280 0 280 0 1 40 MATERIAL DATA SUBMITTAL Jose Tacos 5808 Van Allen Way, Suite 112 Carlsbad, CA 92008 r'S Des Pipe Allied Dyna-Thread Pipe Fittings Tyco Ductile Iron Fittings Mechanical Tee Tyco Fig 40-5 Strap Tee Sprinkler Tyco TY-FRB Recessed Sprinkler Hanger Afcon Fig. 300 Ring Hanger Hanger Afcon Fig 655 All Thread Rod Attachment Sammy Wood Vertical Mount AS 140273 Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpjohnc@gmail.com Page * 1-2 3-10 11-12 13-19 20 21 22 (S S Full Line Sch-40 Replacement Dyna-Thread' offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. S Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, IJLC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. ~D ei Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40fDyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). f!Speci fications NPS Nominal I.D. Wt. WI. (1120 Filled) Pc WtlUft (21') Wtititt (24') Wt/Lift (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/F!; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 105 1Y4 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1'/? 1.639 2.290 3.22 44 2115 2418 2511 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 103 tqco/F/ow Control (') cIIje3 16100 S. Lathrop• Harvey, IL 60426 11350 Norcom Rd. • Philadelphia, PA 19154 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: 1 (800) 882-5543 Fax 708-339-1806 S3-3 Submittal Data Sheet Dyna Threade Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch40 is specified. Stamp Here Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". NPS Nominal I.D. M. WI. (H20 Filled) Pcs/ WI/lift(211) Wi/tIlt (241) Wi/tIlt (25' In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105i 11R 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1h/2 1.639 2.290 3.22 44 2115 2418 2511 40 41.6 3.4 4.79 44 959 1097 114 2 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February I, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as (U@L are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is Listed Approved Listed manufactured with Black lacquer coating. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: S3-4 tqC0 Fire & Building liProducts Technical Services: Tel: (800) 381-9312/ Fax: (800)791-5500 0 [I Pipe Fittings NPT Threaded, Ductile Iron General Description The Tyco5 Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI B1.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty Is given for products or components manufactured by companies not af-filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable JANUARY, 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made In lieu of any and all other warranties, ex- cress or implied, including warranties of merchantability and fitness for a carticular curoose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. tregistered trademark of E. I. du Pont de () Nemours and Company or Its affiliates. TFPI7IO Page 2otlO TFPI7I0 FIGURE 811 FIGURE 813 900 ELBOW 450 ELBOW Figure 811 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 00 0.44 (19,0) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0,29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (30,2) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0,79) (42,7) (23,9) 1.56 3.28 86204 1.94 1.00 (39,6) (1,49) (49,3) (25,4) TABLE I NOMINAL DIMENSIONS FIGURES 811 & 813 Nominal Pipe Figure 813 Size ANSI A Approx. Inches Inches Weight Part DN (mm) Lbs. Number, (kg) 1/2 1.13 0.22 86780 0N15 (28,7) (0,09) 3/4 1.31 0.33 86781 DN20 (33,3) (0,15) 1 1.50 0.48 86280 0N25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 DN32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2.25 1.55 86283 DN50 (57,1) (0,70) 2-1/2 2.69 2.70 86782 DN65 (68,3) (1,22) TFPI7IO Page 3 of 10 FIGURE 812 90 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Weight Part Inches Inches Inches Inches Inches Lbs. DN (mm) (mm) (mm) (mm) Number (kg) 314x1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20 x 15 (30,2) (30,2) (16,0) (16,0) (0,15) 1 x1/2 1.25 1.38 0.56 0.81 0.44 86210 0N25 x 15 (31,8) (35,1) (14,2) (20,6) (020) 1 x3/4 1.38 1.44 0.69 0.88 0.53 86211 DN25 x 20 (35.1) (36,6) (17,5) (22,4) (0,24) 1-1/4x1/2 1.31 1.50 0.63 0.94 0.64 86212 0N32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-1/4 x 3/4 1.44 1.63 0.75 1.06 0.75 DN32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 86213 1-1/4x1 1.56 1.68 0.88 1.00 0.77 86214 DN32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35) 1-1/2x3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40x20 (38,1) (44,4) (19,0) (30,2) (0,43) 1-1/2 x 1.63 1.81 0.88 1.13 0.99 86215 DN40 x 25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-1/2x1-1/4 1.81 1.88 1.13 1.19 1.14 86216 DN40 x 32 (46,0) (47,8) (28,7) (30,2) (0,52) 2x3/4 1.63 1.94 0.88 1.38 1.39 86217 DN50x20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 DN50x25 (44,4) (52,3) (50,8) (33,3) (0,72) 2 x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50x40 (50,8) (55,6) (31,8) (36,6) (0,76) 2-1/2x2 2.38 2.63 1.25 1.88 3.01 86262 DN65 x 50 (60,5) (66,8) (31,8) (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 11 TFPI7I0 Page 5of 10 Nominal Pipe Size ANSI Inches DN 112 DN15 3/4 DN20 1 0N25 1-1/4 0N32 1-1/2 DN40 2 DN50 2-1/2 DN65 _ Wil FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING Figure 814 Figure 818 A B Approx. A B Approx. Inches Inches Weight Part Inches Inches Weight Part (mm) (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) 1.13 0.56 0.33 86340 1.38 0.31 0.18 72779 (28,7) (14,2) (0,15) (35,1) (7,9) (0,08) 1.31 0.75 0.50 86341 1.63 0.56 0.26 72778 (33,3) (19,0) (0,23) (41,4) (14,0) (0,11) 1.50 0.81 0.85 86230 1.75 0.38 0.44 72755 (38,1) (20,6) (0,38) (44,4) (9,7) (0,20) 1.75 1.06 1.30 86231 2.00 0.56 0.54 72754 (44,4) (26,9) (0,59) (50,8) (14,0) (0,24) 1.94 1.19 1.63 86232 2.19 0.75 0.71 72753 (49,3) (30,2) (0,74) (55,6) (19,0) (0,32) 2.25 1.50 2.63 86233 2.63 1.13 1.15 72752 (57,1) (38,1) (1,19) (66,8) (28,7) (0,52) 2.69 1.56 4.55 86234 3.00 0.75 2.29 72756 (68,3) (39,6) (2,06) (76,2) (19,0) (1,04) TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 TFPI7I0 Page 6of 10 Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 A B C 0 E F Approx. ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part DN Lbs. Number (mm) (mm) (mm) (mm) (mm) (mm) (kg) 1-1/2x1-1/4x1/2 1.44 1.31 1.69 0.69 0.63 1.13 1.03 DN40 x 32 x 15 (366) (33,3) (42,9) (17,5) (16,0) (28,7) (0,47) 86257 1 1-112x1-1/4x3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 DN40x32x20 (38,1) (36,6) (44,5) (19,0) (19,0) (30,1) (0,50) 86258 1-112x1-114x1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 DN40 x 32 x 25 (41.4) (39,7) (460 (22,4) (22,4) (28,7) (0.59) 86259 1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 86260 DN40x32x50 (55,6) (54,1) (50,8) (36.6) (36,6) (57,1) (0,88) 1-112x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 86261 DN40 x 40 x 15 (36.6) (36,6) (42,9) (17.5) (17,5) (28,7) (0,52) 1-112x1-112x314 1.50 1.50 1.75 0.75 0.75 1.19 1.23 86262 DN40x40x20 (38,1) (38,1) (44,4) (19,0) (19,0) (30,1) (0,56) 1-1/2x1-1/2x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 0N40 x 40 x 25 (41,2) (41,2) (46,0) (22,4) (22,4) (28,7) (0,62) 86263 1-1/2x1-1/2x1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 DN40 x 40 x 32 (46,0) (46,0) (47,6) (27,0) (27,0) (30,1) (0,68) 86264 1-112x1-1/2x2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 DN40x40x50 (55,5) (55,5) (50,8) (36,6) (36,6) (31,7) (0.91) 88265 2x1 x2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 DN50x25x50 (57,2) (50,8) (57,2) (38.1) (33,3) (38,1) (0.99) 86266 2 x 1-1/4 x 2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 DN50 x 32 x 50 (57,2) (54,1) (57,2) (38,1) (36,6) (38,1) (1,05) 86267 2x1-1/2x112 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 DN50x40x15 (38,1) (36.6) 1 (47,8) (19,0) (17,5) (33,3) (0,68) 2x1-1/2x3/4 1.63 1.50 1.94 0.88 0.75 1.38 1.61 DN50x40x20 (41,4) (38,1) (49,3) (22.4) (19.0) (35,0) (0,73) 86269 2x1-1/2x1 1.75 1.63 2.00 1.00 0.88 1.31 1.65 86270 DN50 x 40 x 25 (44,5) (41,4) (50,8) (25,4) (22,4) (33,3) (0,75) 2x1-112x1-112 2.06 1.94 2.19 1.31 1.19 1.44 2.03 DN50 x 40 x 40 (52,4) (49,2) (55,5) (33,3) (30,2) (36,6) (0 86272,92) 2x1-1/2x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 DN50x40x50 (57,1) (55,5) (63,5) (38,1) (36,6) (38,1) (1,07) 86273 2x2x1/2 1.50 1.50 1.88 0,75 0.75 1.31 1.50 DN50x50x15 (38,1) (38,1) (47,8) (19,0) (19,0) (33,3) (0,68) 86222 2x2x3/4 1.63 1.63 1.94 0.88 0.88 1.38 1.67 86223 DN50x50x20 (41,4) (41,4) (49,3) (22,4) (22,4) (35,0) (0,76) 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 DN50 x 50 x 25 (44,5) (44,5) (50,8) (25,4) (25,4) (33,3) 86224 2x2x1-114 1.88 1.88 2.13 1.13 1.13 1.44 2.05 DN50 x 50 x 32 (47.8) (47,8) (54,1) (28,7) (28,7) (36.6) (0,93) 86225 2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 86226 DN50x50x40 (50,8) (50,8) (55,6) (31,8) (31,8) (38,1) (0,96) 2x2x2-1/2 2.63 2.63 2.38 1.75 1.88 1.44 3.67 DN50 x 50 x 65 (68,8) (66.8) (60,5) (44,5) (47.8) (36,6) (1.66) 86227 2-112x2x3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 DN65 x 50 x 20 (44,5) (41,4) (58,7) 1 (15,9) (22.4) 1 (44,5) (1.01) 86274 TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 0 Page 8 of 10 TFPI7IO iiniii e, fl hlll FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Size Figure 820 Figure 830 Figure 719 ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part ON (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) (kg) 1/2 0.88 0.15 72776 1.88 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0,06) (47,8) (20,6) (0121) (23,9) (0,04) 3/4 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 DN20 (25,4) (0,10) (5018) (23,9) (0,30) (28.7) (0,08) 1 1.18 033 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 0N25 (30,0) (0,15) (55,6) (20,6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72756 2.50 1.06 1.54 86277 1.38 0.50 86295 0N32 (33,3) (0,24) (63,5) (26,9) (0,70) (35,1) (0,23) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 86296 DN40 (35,1) (0,31) (66.8) (30,2) (0,92) (36,6) (0,32) 2 1.50 0.96 72823 3.13 1.63 3.15 86279 1.50 0.90 86297 DN50 (38,1) (0143) (7915) (41,4) (1,43) (38,1) (0,41) 2-1/2 1.75 1.80 72825 - - - - - - - DN65 (44,5) (0,82) I TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 TFPI7I0 Page 9of 10 EA __ to Eh U FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING TABLE 7 NOMINAL DIMENSIONS FIGURE 825, 827 & 816 Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI Inches Inches Weight Part Inches Weight Part Inches Inches Weight Part ON (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - - DN15 x 15 (38,1) (0,09) 1/2x112 2.00 0.27 72980 - - - - - - - DN15 x 15 (50.8) (0,12) 3/4 x 3/4 1.50 0.22 72981 - - - - - - - DN20 x 20 (38,1) (0,10) 3/4 x 3/4 2.00 0.31 73982 - - - - - - - DM20 x 20 (50,8) (0,14) 3/4 x 1/2 - - - - - - 1.75 0.69 0.38 86772 DN20 x 15 (43,2) (17,5) (0,17) 1 x 1/2 - - 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25 x 15 (26,9) (0,10) (42,9) (12,7) (0,17) 1 x3/4 - - - 1.06 0.18 72762 1.75 0.50 0.53 86229 DN25 x 20 (26,9) (0,08) (43,2) (12,7) (0,24) 1-114x1 - - - 1.19 0.31 72763 - - - - DN32x25 (30,2) (0,14) 1-1/2x1 - - - 1.25 0.53 72757 - - - - DN40 x 25 (31,7) (0,24) 1-112x1-114 - - - 1.25 0.35 72764 - - - - DN40x32 (31,7) (0,10) 2x1 - - 1.38 0.75 72759 - - - - DM50 x 25 (35,1) (0,34) 2 x 1-1/4 - - - 1.38 0.69 72761 - - - - DN50x32 (35,1) (0.31) 2 x 1-1/2 - - - 1.38 0.62 T ______ 72775 - - - - DN50x40 (35,1) (0,28) 0 tqCo /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap General Description , - 1•-. / •1 VdS (.üi) See Fire Protection Submittal Sheet for FM Pressure Rating and Listing/Approval Information The Figure 40-5 Strap is an economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as wellas with theapp/icablestandards of the National Fire Protection Association, in addition to the standards of any otherauthorities ha ving jurisdiction. Failure to do so mayimpair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershouldbe contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, LJLC, and VdS; See Fire Protection Submittal Sheet for exact Listing /Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM B-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade "E" EPDM green color code. (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade 'E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be Immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and property installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership withTyco Fire Products orfor products and components which have been subject to misuse, improperinstallation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards ofanyotherAuthorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit, any other obligation inconnectionwith the sale of products or parts of products. Tyco Fire Products shall notberesponsibleforsprinklersystem design errorsor inaccurate orincompleteinformation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHEThERTYCOFIREPRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. I (B Page 1 of 2 September 2004 TFPI72O Pipe Nominal Dimensions Hole Net Size Size Wt. A C D Run x Inches InchB es Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 11!4" X 1/2° 2.00 1.50 3.50 1.20 1/io 0.84 50.8 38.1 88.9 30.5 30.2 0.4 11/40 x 3/40 2.00 1.50 3.50 1.20 1/16 0.88 50.8 38.1 88.9 30.5 30.2 0.4 1'/4°X ill 2.31 1.68 3.50 1.20 13'16 1.13 58.7 42.7 88.9 30.5 30.2 0.5 11/20 X 1/2 2.12 1.62 3.50 1.32 1/16 0.84 53.8 41.1 88.9 33.5 30.2 0.4 1'/2" X3/4 2.12 1.62 3.50 1.32 1/,& 0.88 53.8 41.1 88.9 33.5 30.2 0.4 11/2 i 2.43 1.80 3.50 1.32 1/16 1.13 61.7 45.7 88.9 33.5 30.2 0.5 2 x 1/2 2.36 1.86 3.74 1.55 1/16 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2" x 3/0 2.36 1.86 3.74 1.55 13/16 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2" x 1" 2.67 2.04 3.74 1.55 1/16 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/2 X /2" 2.61 2.11 4.25 1.80 1/16 0.90 66.3 53.6 1 108.0 45.7 30.2 0.4 21/20 X314° 2.61 2.11 4.25 1.80 13'16 0.99 66.3 53.6 108.0 45.7 30.2 0.4 21/2" x 1' 2.92 2.29 4.25 1.80 1/16 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 11/4°X 1 8 1'/2"X 1 6 2"x 1" 6 21/2"X 1" 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2 of 2 TFP1 720 Figure 40-5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. (:12) General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure IS that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (11-1-1 000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. . Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. tqCJ3 Fire & Building IlProducts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB 28, 4.2, 5.6, and &O K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. AUGUST, 2007 ] =OIL i1 ~4_ J Model/Sprinkler Identification Numbers TY1I3I - Upright 2.81K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT 1Y2131 - Upright 4.21K, 1/2"NPT 1Y2231 - Pendent 4.2K. 1/2"NPT 1Y3131 - Upright 5.61K, 1/2"NPT 1Y3231 - Pendent 5.61K, II2NPT TY4131 - Upright 8.01K, 3/4"NPT 1Y4231 - Pendent 8.01K, 314"NPT TY4831- Upright 8.0K, 112"NPT TY4931- Pendent 8,0K, 1/2"NPT (B TFPI7I TFPI7I ESCUTCHEON 7/161(11,1 mm) PLATE SEATING ,, NOMINAL SURFACE 1/2 NPT MAKE-IN -r- 2-3/16" \ (55,6 mm) 1-1/2" (38,11 mm) SSP DEFLECTOR * Page 3 of 10 STYLE 100r20 RECESSED SSU* ESCUTCHEON DEFLECTOR 6 7/16" (1111,11 mm) I _____ NOMINAL 1 MAKE-IN 2-316" WRENCH ______ __ (55,6 mm) '. FLATS 1/2" NPT t 2-7/8" (73,0 mm) DIA PENDENT I RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4- Bulb 6 - Deflector 2 - Button Assembly 5 - Compression Screw * Temperature rating is indicated on deflector or adjacent orifice seat on frame. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3 131) AND PENDENT (TV3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 0r40 PLATE SEATING NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON SSU* 6*: 2-5/16" NPT DEFLECTOR T_ — (1 mm) H 1/2" (58,7 mm) OMINAL Il II 4 MAKE-IN 1-9/16" I 2-1/4" WRENC (57,2 mm) V (39,7 mm) - 2-7/8" (73 m) DIA. -__J 3/4" NPT FL SSP DEFLECTOR* PENDENT REC D PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 0 Page 4of1O TFPI7I 7/16 (11,1 mm) NOMINAL SStJ 1/2' MAKE-IN DEFLECTOR NPT 2-1/4' f 2-3/16" (57,2 mm) I -.. I / FFLATS (55,6 1-9/16 ' ________ WRENCH I (39,7 mm) EFLECTOR CROSS PE NT UPRIGHT SECTION - Frame 3 - Sealing 4 ulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to Button - Assembly 5 Compression orifice seat on frame. Screw FIGURE 5 UICK RESPONSE SERIES B UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/bar1/2) K = 4.2 GPM/psi112 (60,5 LPM/barll2) K = 5.6 GPM/psil/2 (80,6 LPM/bar1121 K = 8.0 GPM/psil/2 (115,2 LPM/barl'2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel wiTeflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED i WHITE 1POLYESTER LEAD COATED - 5.6 1/2" PENDENT (TY3231) and 135°F/57C Orange 1,2,3,4,5,6,7 1,2,3,5 I155°F168°C Red I 175°F/79°C Yellow UPRIGHT '3131) 200°F193°C Green 286°F/141°C Blue NPT 135°F/57°C Orange 1,2,4,5 N/A RECESSED PENDENT (TY3231)* Figure 10 1155°F/68°C Red I 175F/79°C Yellow 200F/93C Green 135°F/57°C Orange 1,2,3,4,5 N/A RECESSED PENDENT (TY3231)** Figure 11 155FI68°C Red 175°F/79°C Yellow 200°F/93°C Green - 8.0 3/4,, PENDENT (TY4231) and UPRIGHT (1Y4131) 1350F/57eC Orange 1,2, 3,4,5, 6,7 1, 2, 5 155°F/68C Red 175°F/79°C Yellow 200°F/93°C Green 286F/141C Blue NPT 135F/57C Green 1,2,4,5 N/A RECESSED PENDENT (TY4231)* Figure 12 155F/68C Orange 175eF/79.0 Red 200°F193°C Yellow 135FI57C Orange 1,2,3,4,5 N/A RECESSED PENDENT (TY4231) Figure 13 155F/68°C Red 175°17/791C Yellow 20DF/93°C Green - 8.0 1/2' NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57C Orange 1,2,4,5,6 1, 2,5 155°F/68C Red 175°F/79C Yellow 200F/93C Green 286F/141C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use In Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-4284444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (1/20 NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4H NPT) 1/2 Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). . N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5,6 AND &O K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED I POLYESTER I COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2° RECESSED PENDENT NPT (TY323) PENDENT (1Y4231) and 4.2 UPRIGHT (TY4 131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 OR I UPRIGHT (1Y3131) 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 115 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (1Y4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135F/57°C to 3/32 inch (2,4 mm) for the 2860F/141C temperature ratings. A leak tight 112 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.Ibs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed TFPI7I 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm (15,9±6,4 mm) 2-1/4" DIA 1/4'(6,4 FACE OF (5712 mm) MO TING SPRINKLER PLATE FITTING I 1/8" fly u MOUNTING SURFACE _____ SERIES 1-1/4" (31,8 mm) I CLOSURE TY-FRB 3/4" (19.1 mm) FIGURE 10 RIES TY-FRB RECESSED PENDENT WIT TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4" (73,0 mm) - 3/4"(19.1 mm) (15,9±6,4 mm) 2-114" DIA. 1/4" (6,4 m (57,2 mm) FACE OF MOU ING SPRINKLER TE FITTING I (3.2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/18" (33,3 mm) TY-FRB 13/16"(20,6 mm) FIGURE 12 S IES TY-FRB RECESSED PENDENT WIT 0-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 - 2-7/8" DIA. (73,0 mm) 1/2±1/8" 1/r2"(12,7 m (12,7*3,2 mm) 2-1/4" DIA. 1/4" (6,4 m) FACE OF (57,2 mm) MO TING SPRINKLER PLATE FITTING / 1/8" I - (3.2 mm) \ MOUNTING SURFACE CLOSURE SERIES 1-1/4'(31,8 mm) TYFRB 1- (25,4 mm) FIGURE 11 RIES TY-FRB RECESSED PENDENT WI TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8"DIA. (73.0 mm) 1/2"(12, mm) (12,7±3.2 mm) 2.1/4' DIA. -.__. 1/4" (6,4 (57,2 mm) FACE OF MO TING SPRINKLER LATE FITTING I - (3.2 mm) _ -i MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFR8 1-1/16"(27.0 mm) FIGURE 13 RIES TY-FRB RECESSED PENDENT WIT TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A' USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4' NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS ft PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. 0 Page 10 of 10 TFPI7I P/N 57-XXX-X-XXX L I MODEL/SIN 330 2.BK UPRIGHT (1/2"NPT) TYII31 331 2.81< PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2°NPT) TY2131 341 4.21< PENDENT (1/2"NPT) TY2231 5.61< UPRIGHT (1/2'NPT) TY3131 E71 5.61K PENDENT (1/2"NPT) TY3231 390 8.01< UPRIGHT (3/4NPT) TY4131 391 8.0K PENDENT (314"NPT) TY4231 360 8.0K UPRIGHT (112"NPT) TY4831 361 8.01< PENDENT (1/2"NPT) TY4931* I I L 135 SPRINKLER 155 175 200 286 RATING 1 NATURAL BRASS 155F/68°C 4 WHITE POLYESTER 175°F/79°C 3 WHITE (RAL9O1O)* 200°F/93C 9 CHROME PLATED 286F/141C 7 I LEAD COATED * Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TV-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 IMPERIAL MAX REC. LOAD LBS. METRIC PIPE ROD PIPE ROD 112 3/8 400 10 314 3/8 400 20 10 400 25 10 11/4 3/8 400 32 10 11/2 3/8 400 40 10 2 3/8 400 50 10 21/2 318 600 65 10 3 318 600 80 10 31/2 3/8 600 10 1000 122_ ...10. 5 1250 125 12 6 112 1 1250 1 150 12 8 1250 1 200 1 12 * Order Part #300m Note: 1/2 Ring Hanger not <FM> approved F~ 300 RING HANGER zS A)US I thru 4 Inch pipe 1/2 and 3/4 Inch pipe 5 thru 8 Inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mil. Galvanized to G-90 specification. FINISH - Mil. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H- 171 (Type 10), Manufacturers Standardization Society ANSIIMSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - 1 thru4 inch: * Offset edge for EASY pipe insertion. 1 thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru 3 inch: * UL listed to accept AFCON#3 10 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index JAcn 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in 1 inch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. 2/00 C, SIS] 1iTi 1&V1W1 Mount) Use #14 Nut Driver (Item #100) Item # Model Shk Lgth Shk Dia Box Qty i 1 g0 Case Qty GST.750 (per 20 3/4 1/4 100 4.75 1000 21 GST 100 1 1/4 100 5.00 1000 22 GST 200 2 1/4 100 6.50 1000 23 GST 300 3 1/4 100 7.50 1000 24 GST 600 6 1 1/4 50 9.00 500 WOOD - Sammys 3 I #14 (Item #100-black) Sammys 114". 318" rod Not less than 2" nominal width (1112") U .0 mE mE U S 0 WOOD - 3/:" Rodr&ni IliTliTi Use #14 Nut Driver (Item #100) Approvals Item # Model Shk Lgth Shk Dia FMTest Loa lb. ULTest Load lb. UIJFMActual Pipe Size Pullout Box Qty 10 CST.75 3/4 1/4 564#-6Ply 100 NFPA 11 GST 10 1 1/4 2104- 7/16 OSB 100 670# - 3/4" Ply IUI..fMFPA 12 GST 20 2 1/4 9404 8504 3/4-2 1/2 1760# - Fir 100 UL4'4FPA * 27 GST 25-380 21/2 3/8 15004 4 21134 - Fir 50 UL4M('JFPA 13 GST30 3 1/4 14754 1500# 3/4-4 20604 - Fir 100 NFPA 403 GST40 4 1/4 2180#-Fir 50 NFPA 14 GST60 6 1/4 22304-Fir 50 #I4SW (Item #101-red) Sidewinders & Sammys 1/2" rod I•I•] Use #14SW Nut Driver (Item #101) Item# Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight (per 100) Case ~Y 8 CST2 2 1/4 17604- Fir 50 7.00 500 * 06 GST2.5-380 21/2 3/8 21134- Fir 50 10.00 500 15 GST3 3 1/4 22754- Fir 1 50 1 10.50 500 16 JGST4 4 1/4 2180#-Fir 50 10.60 500 17 JGST6 6 1 1/4 2230#-Fir 1 50 1 10.95 500 O Double Sheetrock Ceiling Wood Flooring Tr TJI Joist/ Truss Consult truss manufacturer for recommended installation point. q Wood Joist *pre dr illing may be required for items #27 and #06. - Tools available on page 9. Minimum 2" imbedment into base For vertical use. material for NFPA 13 compliance Install in center of lowerface. lb 22 Page 4 Nose: Screws must be installed with appropriate nut driver to comply with warranty