HomeMy WebLinkAbout6221 METROPOLITAN ST; 102; FPC2022-0074; Permit1:iP 11:1 is]:I craty of Carlsbad ift1L Print Date: 09/13/2022 Permit No: FPC2022-0074 Job Address: 6221 METROPOLITAN ST, # 102, CARLSBAD, CA 92009-3096 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132600104 Track #: Applied: 04/21/2022 Valuation: $0.00 Lot #: Issued: 05/09/2022 Occupancy Group: Project #: Finaled Close Out: 09/13/2022 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Robinson, Jarrod Plan Check #: Cheung, Nathaniel Salcedo, Felix Project Title: Description: COASTAL PAIN -SPRINKLER TI (17 HEADS) Applicant: FPContractor: EPIC FIRE PROTECTION INC EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 SAN MARCOS, CA 92069-8126 (760) 310-6122 (760) 310-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7-100 heads $607.00 Total Fees: $607.00 Total Payments To Date: $607.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov hI,ATERAL [DATA SUB["*-ll T7AL EPIC FIRE PROTECTI, IN C. 75 TURTLE POINT WAY SAN MARCOS, CA 9209 (760)310-0122 FAX(70)798-055 tqcas Worldwide www.tyco-fire.com Contacts Series TYFRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 LLIJILII The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.61K, 1/2 in. NPT TY323. . . .Pendent 5.61K, 1/2 in. NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/psl½ (80,6 LPM/bar½) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly . . . Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze AUGUST 2018 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. TFPI72 TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16° (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* I (11,1 mm) f,/\\ ______ I NOMINAL Ii I I iI I 7/16 MAKE-IN I I (50,8 mm) 2 , ' 2° '\I ___ WR 3 ' ' (50,8 mm) _______ (34,9 mm) _____________ Fl 1/2° NPT** DEFLECTOR* k...- 2-7/8° (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 2-7/8 DIA. (73,0 mm) 2-1/4 DIA. FACE OF (57,2 mm) 5/8° (15,9 mm) SPRINKLER FITTING - r FLUSH 3/8±5/16" (9,5±7,9 mm) 117 MOUNTING / 1/8° J SURFACE// (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8° (34,9 mm) TY-FRB PLATE 3/4° (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4° DIA. FITTING (57,2 mm) 5/16±1/4° / \ I (7,9±6,4 mm) 1 FLUSH tMOUNL>1/ J 1 SURFACE \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TV-FRB PLATE 7/8 (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I OLYESTERC 5.6 1/2 in. NPT UPRIGHT (1Y313) and PENDENT (TY323) ________________ 135°F (57°C) Orange 1, 2, 3, 4, 5, 6 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY323) Figures 4a and 5b 135°F (57°C) Orange 1,2,3,4 °F (68°C) Red °F (79°C) r200'F(93'C) Yellow Green Notes: I. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Usted by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2 in. NOT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. MPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. C. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Na 77 — xX — XXX SIN F SPRINKLER I TEMPERATURE FINISH I I RATINGS NATURAL BRASS PURE WHITE (RAL901O)a POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) POLYESTER 9 CHROME PLATED Notes: a. Eastern Hemisphere sales only 135 135°F(57°C) 155 155°F(68°C) 175 175-F (79-C) 200 200°F (93°C) 286 286-F (141-C) 370 1 5.6K UPRIGHT (1/2 in.NPT) I TY313 371 1 5.6K PENDENT (1/2 in.NPT) I TY323 Notes: a. Use suffix 1" for ISO 7-1 connection; for example, 77-370-4-175-I TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 © 2018 Johnson Controls. All rights reserved. All specification, and other information shown were current as of document revision data and are subject to change without notice. Johnson / 4( NATIONAl. FATE PROTECTION ASSOCIATION and NFPA ara rsflororad Iradenra,1,a of National P1w PrarovSonAaoaclatIsn IAFI.ON on raginterad tmda,ns,kafDcPavl Controls tqca Worldwide www.tyco4ire.com Contacts Series RFII - 5,6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers fea- turing a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensi- tive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 in. (12,7 mm) of ver- tical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Pro- tective Cap. When ceiling installa- tion is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. See Figure 5. The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb 1Y3551 - 5 mm bulb AUGUST 2020 Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Criteria section. TY3531 (3 mm Bulb) is UL Listed, C-UL Listed and NYC Approved (M EA 353-01-E) as Quick Response. TY3531 (3 mm Bulb) is VdS Approved (Certificate No. G4090007). TY3531 (3 mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) as Standard Response. Note: FM and LPCB do not approve concealed sprinklers for quick response. TY3551 (5 mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a19), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (TY3551) Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139° F (59°C) Cover Plate 200°F (93°C) Sprinkler with 165°F (74°C) Cover Plate TFPISI 1/2 NPT FRAME SUPPOR CUP WITI ROLL FORIV THREADS GUIDE PINS (2) DEFLECTOR __1 L------J SPRINKLER/SUPPORT CUP ASSEMBLY EALING SEMBLY CAP BULB PRESSION 'CREW LECTOR ROPPED POSITION) THREAD INTO H fl RETAINER SUPPORT Ii WITH THREAD CUP UNTIL D _- DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING ___ _/ N_mr if LL SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY TFPIBI Page 2 of 4 Discharge Coefficient K= 5.6 GPM/psi1/2 (80,6 LPM/bar112) Adjustment 1/2 in. (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ............................Bronze Support Cup ...................Plated Steel Guide Pins..................Stainless Steel Deflector ..........................Bronze Compression Screw ..................Brass Bulb...............................Glass Cap .....................Bronze or Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer............................Brass Ejection Spring ..............Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Johnson Controls at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. 'i.iii Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 155°F (68°C) and 3/32 in. (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. See Figure 3. Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING DIMENSION C SPRINKLER SUPPORT CUP ASSEMBLY 1/2"(12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, I RETAINING RING 74 MOUNTING SURFACE Fx/ __ __ _____•1_________ I I 3/16 to 11/16 MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32 (2,4 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE - PROFILE DEPTH DIAMETER DIMENSION B DIMENSION A 3-1/4 in. (82,6 mm) C: 2-3/8 to 2-5/8 in. (60,3 to 66,7 mm) 3/16 in. (4,8 mm) D: 1-3/4 to 2-1/4 in. (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPIBI Page 3 of 4 Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. See Figure 4. The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Pro- tective Cap. i'L•.ItM As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been completed with the 2-1/2 in. (63,5 mm) diameter clearance hole and in prep- aration for installing the Cover Plate! Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, see Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented accord- ing to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer, shown in Figure 2, or the Air and Dust Seal, shown in Figure 5, contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling, you must reposition the Sprinkler Fitting. TFPI8I Page 4 of 4 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING ..-\ H SEAL BEVEL AS COVER SHOWN PLATE RETAINER ASSEMBLY // AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Care and Maintenance The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 in. (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation Section. Exercise care to avoid damage to sprin- klers before, during, and after instal- lation. Replace sprinklers damaged by dropping, striking, wrench twist- ing, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation section. If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating, P/N* (specify): 155°F (68Cl 200°F (93°C) TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 * Use Suffix 1° for ISO 7-1 connection; for example, 51-792-1-155-1 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brushed Brass .. 56-792-1-135 56-792-1-165 Brass..........56-792-2-135 56-792-2-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003).... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 56-792-6-165 Brushed Chrome........56-792-8-135 56-792-8-165 Chrome........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075 Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001 1400 Pennbrook Parkway, Lansdale, PA 19448 I Telephone +1-215-362-0700 02020 Johnson Control.. All rights reserved. All specification, and other information shown were current anal document revision dote and are aa bleat to change without notice. Johnson OkkilNATIONAL FIRE PROTECTION ASSOCLRTION and NFPAore roglolarod trcdomarl,nof Notional Fir. ProtocticnAscooIotlen TEFLON lsureslsteredtredomark of Dupont Controls A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: Has a Corrosion Resistance Ratio of 1.0 Has a Pressure Rating of 300 psi Is Lighter Weight Than Schedule 40 Is Approved by Factory Mutual and Listed by Underwriters Laboratories Is Produced in Accordance to ASTM A-135 and A-795 Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves Is Produced From Steel With Excellent Properties of Strength and Threadability Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* Offers Lower Freight Costs EDDYTH READ 40 SPECIFICATIONS I 1JRYA'S Ii I& iF @Mkg wr J 1 1.461 1.083 70 11/4 2.070 1.418 51 11/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS I iL XLM I 1 1.00 1.00 11/4 1.00 1.00 11/2 1.00 1.00 2 1.00 1.00 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, Chesterfield, MO 63017 contact your salesperson today at (800) 325-4467 (800) 325-4467 or (636) 537-2600 LISTED BULL. IVIDOBE TUBE CONIP4NY FAX: (636) 537-2645 in the USA, or from Canada ______ www.bullmoosetube.com call (800) 882-4666 Ae> A CAFAD company e-mail:sales@bullmoosetube.com APPROVED At information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 F Threaded Mechanical Branch Tee The MT-30 mechanical tee serves the same function as the MT-1 and MT-8, but uses a steel electro-plated u-bolt to save space and for easier installation in tight places.The MT-30 is ideal for direct connections with sprinkler heads and drop nipples. The MT-90 is the BSPT equivalent. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. c® USTEIJ APPROVED For Listings/Approval Details and Limitations, visit our wobsite at onwvanvilintl.com or ,ontacn an AnvrP Salon Representative. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 U-BOLT & NUTS: U-bolt is carbon steel SAE J429 Gr. 2, zinc plated complete with hex flanged lock nuts conforming to ASTM A-563 Gr. A or B of SAE J995 Gr, 2. THREADS: NPT per ANSI/ASME 81.20.1. COATINGS: o Zinc Electroplated E] Other available options: Example: RAL3000 or RAL9000 Series GASKETS: Materials Properties as designated in accordance with ASTM D-2000. El Grade "E" EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services not involving hydrocarbons, oils or gases. NOT FOR USE WITH HYDROCARBONS. PROJECT INFORMATION APPROVAL STAMP Project: i:j Approved Address: []Approved as noted Contractor: i=i Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-10.16 qCSP7F/RNV1i"L Threaded Mechanical Branch Tee -I 1IcI, THREADED IMECHANICAL Nominal Hole Dimensions Max. Hole Approx. Dimensions I Mm. Diameter Max. Diameter A B C Take-out Size PressureA Wt. Ea. InjDN(mm) Injmm Inj,nm In/mm PSI/bar In./mm In./mm Injmm InJmm Lbs./Kg 1%x½ 1.660x0.840 13A6 P/it 300 21/t 3V2 21/4 11/8 0.8 32x12 42.4x21,3 30 33 20.7 54 89 57.2 42 0.4 1Y4X 3/4 1.660x 1.050 1/I6 PAt 300 2½ 31/2 21/4 15A 0.8 32 x 19 42.4 x 26.1 30 33 20] 54 89 57.2 42 0.4 11/4 X1 1.660x1.315 1/it PAt 300 21/4 31/2 21/4 11A 1.1 32x25 42.4 x33.7 30 33 20.7 58 89 57.2 41 0.5 1½x½ 1.900x0.840 1/16 P/it 300 21/4 31h 21/4 1/t 0.8 40x 12 48.3x21.3 30 33 20.7 57 89 57.2 48 0.4 1½ x 3/4 1.900 x 1.050 1/it 1,/16 300 21/4 31/2 21/4 1/4 0.9 40x 19 48.3x 26.7 30 33 20.7 57 89 57.2 48 0.4 1½x1 1.900x1.315 1/it PAt 300 2% 31/2 21/4 1'A 1.1 40x25 48.3x33.7 30 33 20.7 61 89 57.2 48 0.5 2 x ½ 2.375 x 0.840 1/it 1/it 300 21/7 31/4 21/4 2 0.9 50x 12 60.3x21.3 30 33 20.7 64 95 57.2 51 0.4 2 x1/4 2.375 x 1.050 13A6 P/it 300 21/2 33/4 21/4 2 0.9 50x If 60.3x26,7 30 33 1 20.7 64 95 57.2 51 0.4 2 x 2.375 x 1.315 1/io P/lb 300 2/8 33/4 2% 2 1.1 50x25 60.3x 33.7 30 33 20.1 67 95 57.2 50 0.5 21/2 x ½ 2.875 x 0.840 l/t 1 Yt 300 2/4 41/4 21/4 2% 0.9 65x 12 73.Ox 21.3 30 33 20.7 70 108 51.2 57 0.4 21/2 x 3/4 2.875 x 1.050 13116 1 '/1t 300 23/4 41/4 21/4 21/4 0.9 6519 73.Ox 26.1 30 1 33 1 20.7 1 70 108 57.2 57 0.4 21/2 x 1 2.875x 1.315 11/16 P/i6 300 1 21/8 41/4 21/4 21/4 11 65x25 73,0x33.7 30 33 20.7 73 1 708 1 57.2 1 56 1 0.5 8SF equivalent is available as a MT-90. A - Working Pressure Ratings are for reference only and based on Sch. 10 and Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Note: lighten nuts alternately too recommended torque of 18-22 ft-lbs. (25-30 Nm) an pipe wall less than schedule 10 (Din 24.40) or 23-27 ft.-16s. (31-37 Nm) on pipe walls schedule 10 (DIN 2440) and above. WARNING For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok5 XtremeTM Lubricant is required. FP-10.16 Threaded Mechanical Branch Tees MAWIL Step 1 r Alignment 2Attach Housing Assembly Align the gasket and fitting above the 1.19 (30mm) pipe hole. the U-bolt from the other side and fasten the nuts EQUIVALENT finger tight. BRANCH SIZE HOLE tSAW ASIZE Inches (mm) Inches +4,-O (mm +3,4 (see note) 1 1.19 5 25 30.23 1.52 Note: Flow Data is e>pressed as Feet/Meters of Schedule 40 steel outlet pipe with a "Hazen-Williams coefficient of friction value of 120" t)Tighten Nuts r,) Making sure the fitting is properly located over the pipe hole, use a /ie' 04 mm) wrench to tighten the nuts alternatively to a recommended torque of 18-22 ft-lbs. (25-30 Nm) on pipe wall less than schedule 10 (DIN 2440) or 23-27 ft.-lbs. (31-37 Nm) on pipe walls schEdule 10 (DIN 2440) and above. Specified bolt torque is for the u-bolt used on SPF® threaded mechanical branches. The nuts must be tightened alternately and evenly until fully tightened. Caution: Proper torquing of mechanical branch u-bolt is required to obtain specified performance. Over torquing the u-bolt may result in damage to the pipe and/or casting which could result in pipe joint separation. Under torquing the u-bolt may result in lower pressure retention capabilities, lower bend load capabilities, joint leakage and pipe joint separation. Pipe joint separation may result in significant property damage and serious injury. FP-10.16 iTji:] 1/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 162 REVERSIBLE UNIVERSAL BEAM CLAMP 3/4" MOUTH RESTRAINING STRAP Nut optional, if insufficient rod dimension le SIZE - 3/8" and 1/2' rod. MATERIAL - Ductile iron. FINISH - Plain. E.G. and H.D.G. LISTINGS - O'ta 203-EX 2551 > Approval guide - Pipe Niagara FUNCTION - Hanger assembly attachment to steel flange with thickness of less than 3/4'. INSTALLATION- Per NFPA 13 with set screw up or down. Torque - 3W- 60 Inch lbs. or 1/2"= 125 louis lbs. In the absence of a torque wrench, engage set bolt finger tight then additionally tighten 1/3 turn. FEATURES Listings allow installation with set screw up or down - see drawings. Maintains CONSTANT HANGER CENTER-LINE, with set screw up or down. * Flat throat back to prevent twisting on flange during installation. ORDERING - Part 4, rod size and finish. SIZE- One tue fits both 3/8" and 1/2' rod or set screw. Available lengths 4" and longer. MATERIAL- Carbon Storm. FINISH - Mil. Galvanized. LISTINGS- c ti-.,. 203-EX 2551 PATENT - No. 5,897,088 FUNCTION - To enhance hanger attachment in areas subject to Ea INSTALLATION - Install tight to structure and component pans Minimum return on strap: I" L-dimension in measured (torn banger rod center FEATURES to the strap end. Fast installation for new construction or retrofit. Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component pans. (See drawings ORDERING - Part 4 and L'dimension. GENERAL INFORMA110N .inoWrs GENERAL INFORMATION SECTION CONTENTS GeneraHANGERMATE® 'ORS Rod Hanging Anchors Installation Specifications ..............2 ________________________________________________________________ Performance Data............................3 ,_PRODUCT DESCRIPTION------- Ordering Information.......................5 Hangermate is an all steel threaded fastening system for suspending steel threaded rod vertically overhead in pipe hanging, fire protection, electrical conduit and cable-tray applications. They are available in versions which can be installed in a variety of base materials including steel purlins, bar joists and beams, wood frame columns and beams, as well as concrete ceilings, beams and columns > rn Steel threaded rods in 1/4' and 3/8 diameters can be vertically suspended with Hangermate (a 1/2' diameter size is also available for wood). They are also offered in a side mount style for lateral installation of 1/4" and 3/8' diameter steel threaded rods onto joists, columns and overhead members. For all steel and wood hangers, a Hangermate Socket Driver is recommended to provide proper installation with a drill screw gun. For concrete hangers, a powered impact tool with a clutch is recommended. A pivot head version is also available for flexible connection angle and positioning of rod hangers. An acoustical ceiling eyelet version is also available for hanging wire or cable attachments. GENERAL APPLICATIONS AND USES Hanging Pipe and Sprinkler Systems • HVAC Ductwork and Strut Channels Suspending Conduit and Cable Trays • Suspended Ceilings Lighting Systems and Overhead Utilities e Mounting Security Equipment FEATURES AND BENEFITS + Ease and speed of overhead installation + Lower in-place cost, when compared to beam clamps, lag bolts and dropins + Steel and wood Hangermate can be installed with a drill screw gun + Side mount versions available for steel and wood Hangermate + Socket drivers, pole tool and accessories to optimize ease of installation FM Approvals (FM) - see listing for applicable sizes and types Pipe Hangers components for automatic sprinkler systems - File No. JI 3015153 Underwriters Laboratory (UL) - see listing for applicable sizes and types Pipe Hangers - File No. EX 1289 STEEL HANGERMATE WOOD HANGERMATE CONCRETE HANGERMATE ANCHOR MATERIALS Zinc Plated Carbon Steel ANCHOR SIZE RANGE (TYP) 1/4" to 3/8" for Steel 1/4"tol/2" for Wood 1/4' to 3/8" for Concrete (Threaded Coupler Heads) THREAD VERSION Unified Coarse Thread UNC) SUITABLE BASE MATERIALS Steel Purlins and Beams Wood and Timber Concrete Members CSI Divisions: 03 16 00 - Concrete Anchors, 05 05 23 - Metal Fastenings and 06 05 23 - Wood, Plastic, and Composite Fastenings. Rod Hangers shall be Hangermate anchors as supplied by DEWALT, Towson, MD. Anchors shall be installed in accordance with published instruction and the Authority Having Jurisdiction. 3 21/2 through 8" Size 1/2" through 2" Size Rounded Edge Design C&<> LISTED APPROVED ]Fg0 69 (Formerly Afcon Fig. 300) Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range: 1/20 through 8' Material: Carbon steel Finish: Strap is Pre-Galvanized Zinc Material. Nut is Zinc Plated. Service: Recommended for suspension of non-insulated stationary pipe line. Maximum Temperature: 4500 F Approvals: Complies with Federal Specification A-A-1192A (Type 10), WW-H-171-E (Type 10), and ANSI/MSS SP-58 (Type 10). UL Listed and FM Approved (Sizes '/4"- 8'). Features: 1/2's - 2" sizes designed for use with steel and CPVC piping and manufactured with FBC System Compatible oil. Threads are countersunk so that they cannot become burred or damaged. Knurled swivel nut provides vertical adjustment after piping is in place. Captured swivel nut in the 1/2" through 6' sizes. The capture is permanent in the bottom portion of the band, allowing the hanger to be opened during installation if desired, but not allowing the nut to fall completely out. Ordering: Specify size, figure number and name. Non-captured nut also available upon request. I . A r- -,,I A r~ A2~v~ I F J.q I `NiXG 1/2 through 1" pipe FIG. 69: DIMENSIONS (IN) o LOADS_(LBS) o WEIGHT_(LBS) Pipe Size Max Load Weight A Rod Size B C F G Width 1/2 300 0.10 2/8 2 19A6 11/o 3/4 0.10 2¼ 1/o 15A6 1 0.10 29A6 111A6 1 11/4 0.10 2/ 1/4 7/8 11/2 0.10 2¼ 1/8 2 0.11 31¼ 2/8 21/2 525 0.20 4 2/ 15A6 3/4 31¼ 3 0.20 313A6 215A6 1,46 4 650 0.30 4A6 313A6 19A6 43/s 5 1,000 0.54 1/2 55A6 6 0.65 6A6 59A6 21¼ 8 1.00 89A6 PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: EjApproved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.18 1 1/4" through 2" pipe 21/2 through 8" pipe