Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 208; FPC2017-0222; Permit(7c ity of Carlsbad L1ci Print Date: 10/24/2022 Permit No: FPC2017-0222 Job Address: 2525 EL CAMINO REAL, # 208, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1563020900 Track #: Applied: 08/08/2017 Valuation: $888,943.90 Lot #: Issued: 09/06/2017 Occupancy Group: Project #: Finaled Close Out: 04/16/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Fieri, Dominic Plan Check #: Wong, Cindy Project Title: Description: YARD HOUSE - ALARM TI Applicant: JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS 3568 RUFFIN RD SAN DIEGO, CA 92123-2597 (858) 633-9123 FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP P0 BOX 3042 BOCA RATON, FL 33431-0942 (561) 341-7780 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov SimplexGrinne!I LP 3568 Ruffin Road .1 San Diego, California 92123 t. la.~tL;a P.- 858-633-9100 SimpiexGrinnell 101/I Fire Detection and Alarm System Product Submittal Project: Yard House at The Shoppes at Carlsbad 2525 El Camino Real #208 Carlsbad, CA FPC20I7-0222 2525 EL CAMINO REAL UNIT2O8 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or ddanieIs(äsimpIexqrinnell.com S 1/19/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco. TM SimplexGfinnell Fire Detection and Alarm System Products SimplexGnnnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com Qty Model No. Description C.S.F.M. No. E 4100-9311 FACP (existing) 7165-0026:0251 1 4009-9601 IdNAC Repeater 7300-0026:0375 4 2081-9272 6.2 AH Battery N/A 1 4098-9792 Detector Base 7300-0026:0217 1 4098-9714 Smoke Sensor 7272-0026:0218 5 4098-9756 Duct Detector 3420-0026:0241 5 2098-9806 Remote Test Station 7300-0026:0150 4 4090-9001 Addressable 1AM 7300-0026:0223 5 4090-9002 Relay lAM 7300-0026:0223 5 49V0-WWF Strobe 7125-0026:0373 2 495V-APPLW Speaker Strobe 7320-0026:0322 22 495V-APPLC Speaker Strobe 7320-0026:0322 Business Information Warranty Information S 1/19/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco.TM S ®SimpIEx UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Ilijit*i Master Controller (top) bay standard equipment: 32-Bit Master Controller with color-coded operator interface and raised switches for high confidence feedback Dual configuration program CPU, convenient service port access, and capacity for up to 2500 addressable points CPU assembly includes 2 GB dedicated compact flash memory for on-site system programming and information storage An Enhanced Power Supply (EPS) and battery charger (9 A output) with on-board: IDNAC SLCs (signaling line circuit) for addressable appliance control, an IDNet 2 Module for addressable device control; and programmable function auxiliary output Also available with InfoAlarm Command Center expanded content user interface (see data sheet S4100-0045) Standard addressable device interfaces include: 250 point addressable device IDNet 2 SLC that supports TrueAlarm analog sensors and IDNet communications monitoring and control devices with an electrically isolated output channel allowing use with either shielded or unshielded, twisted or untwisted single pair wiring; and providing dual short circuit isolating output loops MINIPLEX Transponder and remote LCD and LED annunciator support via RUI+ (remote unit interface) communications port with electrically isolated output for use with either shielded or unshielded, twisted or untwisted single pair wiring (refer to details on page 6) Standard power supplies (EPS) provide enhanced power delivery IDNAC SLCs to addressable notification appliances: With IDNAC SLCs, a constant 29 VDC source voltage is maintained during alarm, even during battery operation, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby Efficiencies include lower strobe currents, wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, and the ability to use smaller gauge wiring - all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will also operate during worst case alarm conditions IDNAC SLCs are compatible with both TrueAlert ES and TrueAlert addressable notification appliances, and remote 4009 IDNAC Repeaters to extend power and wiring distance even farther Optional modules and connections include: Fire Alarm Network Interfaces, city connections, and up to five (5) RS-232 ports for printers and terminals Building Network Interface Module (BNTC) for Ethernet connectivity options (see data sheet S4100-0061) Side mounted DACT assembly requiring minimal panel space; DACT is compatible with IP Communicators Emergency communications systems (ECS) equipment; 8 channel digital audio or 2 channel analog audio 4I00ES Fire Control Panels Addressable Fire Detection and Control Basic Panel Modules and Accessories 1 J' LLIi 4100ES Cabinets are Available with One, Two or Three Bays Option Modules (Continued) Additional IDNet 2 communications SLCs, IDNet 2+2 Modules with quad short circuit isolating output loops; additional power supplies, alarm relays, and auxiliary relays LED/switch modules and panel mount printers; VESDA Air Aspiration Systems interface, ASHRAE BACnet Interface, TCP/IP Bridges Battery brackets for seismic area protection (see page 2) 4100E5 compatible legacy interface modules, including control of conventional (non-addressable) NACS (see data sheet reference list on page 12) 4I00ES Listings reference: UL 864, Fire Detection and Control (UOJZ), and Smoke Control Service (LTUKL) UL 2017, Process Management Equipment (QVAX) UL 1076, Proprietary Alarm Units-Burglar (APOU) UL 1730, Smoke Detector Monitor (UTJtH) UL 2572, Mass Notification Systems (PGWM); refer to data sheet S4100-0034 for audio equipment ULC S527, Control Units for Fire Alarm Systems Iii1iif1I'j CPU provides dual configuration programs: Two programs allow for optimal system protection and commissioning efficiency with one active program and one reserve; downtime is reduced because the system stays running during download PC based programmer features: Convenient front panel accessed Ethernet port for quick and easy download of site-specific programming Modifications can be uploaded as well as downloaded for greater service flexibility; AND, firmware enhancements are made via software downloads to the on-board flash memory * See pages 6 and 7 for product that is UL or ULC listed and additional listing information. This product has been listed by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:0251 for allowable values and/or conditions concerning material presented in this document. NYC Fire Dept COA #6151. Additional listings may be applicable: contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4100-0100-13 1/2016 irnrriri 41 ODES Series Fire Detection and Control Panels provide extensive installation, operator, and service features with point and module capacities suitable for a wide range of system applications. An on-board Ethernet port provides fast external system communications to expedite installation and service activity. Dedicated compact flash memory archiving provides secure on-site system information storage of electronic job configuration files to meet NFPA 72 (National Fire Alarm and Signaling Code) requirements. Modular design. A wide variety of functional modules are available to meet specific system requirements. Selections allow panels to be configured for either Stand-Alone or Networked fire control operation. I rnrii :J.i*i.ii11T1 The Master Controller Bay (top) includes a standard multi-featured enhanced power supply (EPS) with IDNet 2 Module, the master controller board, two vertical expansion blocks, and operator interface equipment. The Expansion Bays include a Power Distribution Interface (PDI) for connection of single or multiple block modules, and/or slot style (motherboard/daughter card) modules. The Battery Compartment (bottom) accepts two batteries, up to 50 Ah, to be mounted within the cabinet without interfering with module space. 41OG-6080 DACT Master Controller Bay mounting location WEW P01 board with two connectors available dual slot motherboard Optional 4190-6104 Truelnsight Module [j mounting location I- EPS Power Supply with lONet 2 Module - Typical bays with mixed module sizes 4100ES Module Placement Reference in 3-Bay Cabinet illillilillillill Mechanical Descripticn iiiiiiiii Boxes can be close-nippled; each box provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required Cabinet assembly design has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F, requires 4100-7912 option for additional legacy card stabilizer brackets and battery brackets as detailed on data sheet S2081-0019 The latching front panel assembly easily lifts off for internal access Modules are power-limited (except as noted, such as relay modules) The NEMA 1/]P30 box is ordered separately and available for early installation Doors are available with tempered glass inserts or solid; boxes and doors are available in platinum or red Boxes and door/retainer assemblies are ordered separately per system requirements; refer to data sheet S4100-0037 Operator Interface Detail Reference The following illustration identifies the primary functions of the operator interface. Operator interface panel is directly able and accessible (no acces door) Upload/Download Basic operator instructions Ethernet port access are printed on the interface (under sliding cover) mounting plate 11I' "Install Mode" allows grouping of multiple troubles for uninstalled modules and devices into a single trouble condition (typical with future phased expansion); with future equipment and devices grouped into a single trouble, operators can more clearly identify events from the commissioned and occupied areas Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring "Recurring Trouble Filtering" allows the panel to recognize, process, and log recurring intermittent troubles (such as external wiring ground faults), but only sends a single outbound system trouble to avoid nuisance communications WALKTEST silent or audible system test performs an automatic self-resetting test cycle Support for TrueAlarm individual analog sensing and IDNAC addressable notification with front panel information and selection access S4100-0100-13 1/2016 1977-tl11 rnii [OTSTMne fl !-Th!I . Convenient Status Information. With the locking door Convenient and extensive operator information is closed, the glass window allows viewing of the display, status provided using a logical, menu-driven display LEDs, and available operator switches. Features include a . Multiple automatic and manual diagnostics for two-line by 40-character, wide viewing angle (super-twist) maintenance reduction LCD with status LEDs and switches as shown in the Alarm and Trouble History Logs (up to 1250 entries for illustration below, each, 2500 total events) are available for viewing from the LED indicators describe the general category of activity CD, or capable of being printed to a connected printer, L or downloaded to a service computer being displayed with the LCD providing more detail. For the authorized user, unlocking the door provides access to the Convenient PC programmer label editing control switches and allows further inquiry by scrolling the Password access control display for additional detail. FIRE ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts SIX SYSTEM STATUS INDICATOR LEDs PRIORITY 2 ACK acknowledges a Priority 2 Alarm provide system status indications in addition condition, logs the acknowledge, and silences the to LCD information, LEDs flash to indicate the operator panel and all annunciator tone-alerts ULC SYSTEMS condition and then when acknowledged, SUPV ACK acknowledges system supervisory a require designating Ground Fault remain on until reset: Fire Alarm & Pnonty 2 Alarm, red LED conditions, logs the acknowledge, and silences the indicator Supervisory & Trouble, yellow LED operator panel and all annunciator tone-alerts Alarm Silenced, yellow LED TROUBLE ACK acknowledges system troubles, logs AC Power, green LED (on for normal) the acknowledge, and silences the operator panel and all annunciator tone-alerts THREE PROGRAMMABLE LEDs I ALARM SILENCE causes audible and visible provide custom labeling, the top 2 X 40 LCD READOUT, LED backlighted notification appliances to be silenced (default operation, two LEDs are selectable as red or J during normal conditions and abnormal may be modified through panel programming for yellow, the bottom LED is operating conditions, provides up to 40 compliance with local requirements) W selectable as green or yellow j characters for custom label information SYSTEM RESET restores control panel to normal when I J I [Custom labert FIRST ALARM DISPLAY: Operation can be selected for maintained display of first [alarm all alarmed inputs are returned to normal I I until acknowledged \+ t,.riiweI1 SYSTEM IS NORMAL PLnat ±" 12:25:15 am THU 24-OCT-15 - ALARMS ___________ ,• .n..i . W - jj EkorReI J'TjI - - --- -- - -- -- i . L o'.t Dirty 3ro A ' - L d Fault ICh FIVE PROGRAMMABLE POINT STATUS ADDITIONAL FUNCTION LCD LCD NAVIGATION NUMERIC KEYPAD for FUNCTION SWITCHES, CONTROL KEYS: KEYS: CONTROL: point category and point each with a yellow LED Point Enable and Event Time Request Menu selection selection (alphabet indicator Disable More Information Request Vertical and characters are not used at Force On or Arm Lamp Test J Horizontal position this time) Force Off or Disarm selection buttons Return On/Off or Arm/Disarm to Auto Mode 3 S4100-0100-13 1/2016 Overview. The 4100ES EPS power supply with IDNet 2 TrueAlarm heat sensors can be selected for fixed Module provides addressable initiating device and IDNAC temperature detection, with or without rate-of-rise addressable notification appliance Signaling Line Circuits detection. Utility temperature sensing is also available, (SLCs) that supervise wiring connections and the individual typically to provide freeze warnings or alert to HVAC device/appliance communications status on their SLC. With system problems. Readings can selected as either these 2-wire SLCs, initiation, monitoring, and control devices Fahrenheit or Celsius. such as manual fire alarm stations, TrueAlarm sensors, control TrueSense Early Fire Detection. Multi-sensor relays, and sprinkler waterfiow switches; and notification 4098-9754 provides photoelectric and heat sensor data appliances such as strobes and horns can communicate their using a single 4100ES IDNet address. The panel evaluates identity and status and receive fire alarm system control. smoke activity, heat activity, and their combination, to Additional interface modules include circuit isolators, provide TrueSense early detection. For more details on this conventional DC zone adapters, and interface to other system operation, refer to data sheet S4098-0024. circuits such as fans dampers and elevator controls. L!hI! 111 Each addressable device on an IDNet communication channel is continuously interrogated for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Both Class B and Class A operation is available. Sophisticated poll and response communication techniques ensure supervision integrity and allow for "T-tapping" of the circuits for Class B operation. Devices with LEDs pulse the LED to indicate receipt of a communications poll and can be turned on steady from the panel. With addressable devices, the location and status of the connected device is monitored and logged, and displayed on the operator interface LCD and on remote system annunciators with each device having its own 40 character custom label for precise identification. Addressable initiating device communications include operation of TrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value, peak value, and an average value for each sensor. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. TrueAlarm Addressable Sensor Reference J , TrueAlarm Photo TrueAlarm Photo/Heat Sensor with Base I Sensor in CO Base Programmable sensitivity of each sensor can be selected at the control panel for different levels of smoke obscuration (shown directly in percent) or for specific heat detection levels. To evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read (or downloaded as a report) and compared to the alarm threshold directly in. percent. CO sensor bases combine an electrolytic CO sensing module with a TrueAlarm analog sensor to provide a single multiple sensing assembly using one system address. The CO sensor can be enabled/disabled, used in LED/Switch modes and custom control, and can be made public for communication across a fire alarm Network. (refer to data sheet S4098-0052 for details) Sensor Status. TrueAlarm operation allows the control panel to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 requirement for a test of the sensitivity range of the sensors is fulfilled by the ability of TrueAlarm operation to maintain the sensitivity level of each sensor. CO Sensors track their 10 year active life status providing indicators to assist with service planning. Indicators occur at: 1 year, 6 months, and end of life. Modular TrueAlarm sensors use the same base and different sensor types (smoke or heat sensor) and can be easily interchanged to meet specific location requirements. This allows intentional sensor substitution during building construction when conditions are temporarily dusty. Instead of covering smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. The control panel will indicate an incorrect sensor type, but the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. IDNet Addressable Channel Capacity. The CPU bay standard power supply (EPS) provides an IDNet 2 Module providing a signaling line circuit (SLC) that supports up to 250 addressable monitor and control points intermixed on the same pair of wires. IDNet 2 and IDNet 2+2 Module SLCs are isolated from other system reference voltages to reduce common mode noise interaction with adjacent system wiring. Additional 250 address IDNet 2 or IDNet 2+2 Modules are available. IDNet 2 and IDNet 2+2 SLC Wiring Specifications Maximum Distance 1 t 125 4000 ft (1219 m); 50 ohms from Control Panel 2500 feet (762 m); 35 ohms per Device Load 126-250 Total Wire Length Allowed With Up to 12,500 ft (3.8 km); "T" Taps for Class B Wiring 0.60 iF Maximum Capacitance Between 1 pF IDNet 2 Channels Loading per device 0.8 mA supv., 1 mA alarm; 2 mA per activated device LED Wire Type and Connections Shielded or unshielded, twisted or untwisted wire* Connections Terminals for 18 to 12 AWG (0.82 mm2 to 3.31 mm2) IDNet 2 and IDNet 2+2 Module Compatibility: IDNet communicating devices and TrueAlarm sensors including QuickConnect and QuickConnect2 sensors * Some applications may require shielded wiring. Review your system with your local Simplex product supplier. S4100-0100-13 1/2016 II'] PIi s.riur r irr ii*ir i*i!i S Addressable notification appliance communications problem. Using the TrueAlert magnet test allows each appliance include operation of TrueAlert and TrueAlert ES Visible only to individually identify its candela setting and address and to (V/O, strobe), Audible only (AIO, horn), Audible/Visible (A/V, briefly operate if desired, and using the TrueAlert ES horn/strobe), and strobes of Speaker/Visible (SAT) notification Appliance Self-Test feature provi des detailed performance appliances. (S/V appliances require separate speaker wiring.) verification per appliance. IDNAC SLC addressable communications allow each horn and strobe to be individually controlled using a single two-wire I MITI Mr, S circuit, confirms the wiring connections to the individual notification appliance's electronic circuit, and confirms communications between each appliance and the fire alarm control panel. Addressable communications increases supervision integrity versus conventional notification systems by providing supervision beyond the circuit wiring to each individual appliance and by constantly verifying the ability of each appliance to communicate with the control panel. Individual Appliance Status and Settings. The fire alarm control panel monitors and records each addressable notification appliance status, type of appliance, and its configured appliance settings. A fault in any individual appliance automatically reports a trouble condition to the control panel. TrueAlert ES Addressable Appliance Reference I -I - EJ - - NO (horn) V/O (strobe) AN (horn/strobe) Virtual NACs Provide Control Convenience. For control convenience, IDNAC notification appliances can be grouped into Virtual NACS (VNACs) for group control, grouping that can be made across SLCs, not defined by their wiring connection. Panel Control Convenience. Applicable operation settings for each appliance can be programmed without having to replace appliances or remove them from the wall or ceiling. An appliance's VNAC notification zone can be easily changed through programming without having to add additional circuits, conduit, and wiring. Audible and visible appliances for non-Fire Emergency Communications notification can be programmed to operate separately on the same pair of wires as the fire alarm notification appliances. The result is lower installation, retrofit, and overall life-cycle cost of ownership compared with traditional conventional notification systems. Installation, Retrofit, and Life-Cycle Cost Benefits. With each addressable appliance capable of being controlled separately on the same two-wire IDNAC SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T-tapped" allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Location Information, Diagnostics and Troubleshooting. Each addressable notification appliance has its own 40 character custom label to identify the location of the appliance and to aid in troubleshooting fault conditions. In conventional notification systems, conventional appliances are not capable of communicating with the control panel. Fault reporting on a conventional system is limited to the circuit wiring and the entire area (zone) covered by appliances on the notification appliance circuit (NAC) making it much more difficult and costly to locate and correct the source of a On-Board Test Sensors. TrueAlert ES appliances are equipped with on-board sensors to detect strobe and/or horn output allowing efficient and unobtrusive Self-Testing. When Automatic Self-Test is initiated from the control panel, each appliance within the selected VNAC group will briefly operate and then report its Self-Test status to the control panel, all within several seconds. Silent Self-Test can be selected to test only visible appliance if desired. The control panel is in a trouble condition during testing and in the event of an alarm, Self-Test is automatically terminated. Additionally, Automatic Self-Test can be scheduled to occur at a convenient time on a regular basis. (Requires version 2.03.0 1 or higher software.) Automatic Self-Test results are communicated to the control panel with a time and date stamp and are stored in memory. Results are viewable at the front panel display and printed reports can be generated from the panel service port. (See sample reports on page 11.) Individual Self-Test is selected from the control panel when individual appliances need to be observed to operate. Each appliance in the selected VNAC group will turn on its LED until individually activated by applying a magnet. After performing the individual test, the appliance LED turns off to indicate completion. Results are recorded the same as during the automatic test. EPS Power Supplies provide three, 3 A IDNAC SLCs for control and power to TrueAlert ES and TrueAlert addressable notification appliances. Both power supplies incorporate an efficient switching design that provides a regulated output of 29 VDC, even during battery operation. With 29 VDC minimum output at the panel, addressable notification SLCs can support wiring distances 2 to 3 times farther than available with conventional notification, or support more appliances per SLC, or work with smaller gauge wiring, or combinations of these benefits, all resulting in installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. I I9]T(s*1 sI'III ii ir*'i'iltflTI iti IDNAC SLC Capacity: Up to 127 addresses and up to 139 unit loads (appliances are typically one unit load, devices such as Isolators may require more than one load, refer to individual device data sheet for specific information) Recommended wire type UTP, unshielded twisted pair Maximum wire length allowed with "T-Taps" for 10,000 ft (3048 m) Class wiring, _B_ _per _SLC Maximum wire length per 4000 ft (1219 m) SLC any _to_ _appliance Appliance Supervisory 1 unit load = 0.8 mA per appliance Current Wiring connections Terminals for 18 to 12 AWG (0.82 mm to 3.31 mm2) Installation Instructions (see 579-1015 for more information) S4100-0100-13 1/2016 Mounts in Slot 2 of a two slot motherboard and provides EPS with IDNet 2 Module Details (Continued): one Class B or Class A, RUI+ isolated communications • DCAI (Dual Class A IDNAC Isolator) Module creates channel with earth fault detection RUI+ isolated communications controls up to 31 remote devices per master controller at up to 2500 ft (762 m) for single run, or 10,000 ft (3048 m) total if wiring is Class B and T-tapped; if more distance is required, up to four total RUT channels are supported; add up to three 4100-1291 RUT Expansion Modules (4100-1291 provides unisolated RUT communications) Compatible RUI+ remote equipment includes: MINIPLEX transponders, 4603-9101 LCD Annunciators, and 4100 Series 24 110 and LED/Switch modules RUT Expansion Module 4100-1291 is also compatible with the RUI+ remote equipment listed above; and is required for control of 4602 Series LED/Switch and I/O Annunciator modules, including 4602-9101 Status Command Units (SCU), and 4602-9102 Remote Command Units (RCU); (refer to data sheet S4602-0001) Open slot space on the left of the CPU motherboard is available for either another dual slot motherboard, or for one or two block modules (refer to diagram on page 2) Slot 1 of the motherboard is primarily for the 4100-6078 Network Interface Board with media modules EPS (Enhanced Power Supply) with IDNet 2 Module Details: (see page 9 for specifications) Rating is 9 A output with "Special Application" appliances Outputs are power-limited, except for the battery charger Provides system power, battery charging, auxiliary power, earth detection, on-board electrically isolated IDNet 2 Module with 250 point SLC, three on-board 3 A 1DNAC SLCs, and provisions for either an optional City Connect Module or an optional AlarmlSupv/Tbl Relay Module IDNet 2 Module SLC Output provides Class B or Class A communications for up to 250 addressable devices with dual short circuit isolating loop outputs (see details on page 4) Note: The "IDNet 2 Module" replaced the "IDNet 1+ Module" and the term "EPS with IDNet 2 Module" replaces the term "EPS+" two Class A outputs from one IDNAC SLC Class i3 Input; up to two can be connected to one IDNAC SLC, with up to 6 total per EPS; total Class A output loop current is limited to the 3 A rating of the IDNAC SLC Battery Charger is dual rate, temperature compensated, and charges up to 50 Ah sealed lead-acid batteries mounted in the battery compartment (33 Ah for single bay cabinets); also is UL listed for charging up to 115 Ah batteries mounted in an external cabinet (see data sheet S2081-0012 for details) Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions; status information provided to the master controller includes analog values for: battery voltage, charger voltage and current, actual system voltage and current, and individual IDNAC SLC currents Low Battery Cutout is selectable for each EPS power supply, Canadian models are shipped selected, other models are shipped unselected 2 A Programmable Output: Select for conventional non-synchronous NAC operation to provide supervised reverse polarity for sounder base power, Suppression Release Peripheral (SRP) power, or other coded NAC operation requirements Select for Auxiliary (AUX) operation for sounder base power, 4-wire detector power, or door holder; supervised AUX operation does not require an end-of- line relay to provide Power-Limited operation EPS Mounted Optional Modules (select one): City Connect Module (4100-603 1, with disconnect switches, or 4100-6032, without disconnect switches) can be selected for conventional dual circuit city connections Alarm Relay Module (4100-6033) provides three Form C relays that are used for Alarm, Trouble, and Supervisory, rated 2 A resistive @ 32 VDC S Master Controller Selection lAformation Master Controller and Expansion Bay Selection Model Model Type and Listing 4100-9311 12O VAC, 50/6OHzInput UL 4100-9312 English 12O VAC, 50/60Hz 4100-9313 French Canadian ULC Without IDNet devices: Supervisory = 425 mA Alarm = 735 mA Note: Master Controller current does not subtract from 9 A output rating 4100-9331 120 VAC, 50/60 Hz input UL 4100ES Master Controller Assembly; same as above models except without LCD Display and 4100-9332 120 VAC, 50/60 Hz input, ULC Operator Interface Canadian, English 4100-2300 Expansion Bay Assembly; order for each required expansion bay 4100-2303 Slot Module Stabilizer Bracket, used when expansion bays have style modules (Continued on next page) S4100-0100-13 1/2016 4100-9511 I 220-240 VAC, 50/60 Hz Input I UL Description 4100ES Master Controller Assembly with LCD display, operator interface and RUI+ isolated output communications interface; 9 A EPS (Enhanced Power Supply) with battery charger, electrically isolated 250 point IDNet 2 Module, three Class B IDNAC SLCs, one 2 A output configurable for Auxiliary Power or Simple NAC operation and expansion slot for City Circuit or Alarm/Supv/TbI Current S S S S Module Selection Information Communication Modules Model 4100-6078 Description For Master Controller; mounts in Slot 3 Modular Network Interface; each requires For Redundant Master Controller two media modules (below) Size 1 Slot Supv. 46 mA Alarm 46 mA 4100-6061 1 Slot 46 mA 46 mA 4100-6056 Wired Media Module Select two media cards as required; mounts on Fiber Optic Media Module 4100-6078 or 4100-6061; Class B or Class X operation N.A. 55 mA 55 mA 4100-6057 N.A. 25 mA 25 mA 4100-6047 Building Network Interface Card (BNIC), refer to data sheet S4100-0061 for details 2 Blocks 291 mA 291 mA 4100-6055 Network Access Dial-in Service Modem, mounts to 4100-6078 or 4100-6061 Network Interface Card, requires telephone line connection N.A. 60 mA 60 mA 4100-1291 Remote Unit Interface Module (RUI, unisolated); up to 3 maximum per control panel 1 Slot 85 mA 85 mA 4100-6031 Select one per EPS (Note: maximum one City Circuit module per panel) City Circuit, with disconnect switches N.A. 20 mA 36 mA 4100-6032 City Circuit, w/o disconnect switches N.A. 20 mA 36 mA 4100-6033 AlarmlSupvlrbl Relay, 3 Form C relays, 2 A @ 32 VDC N.A. 15 mA 37 mA 4100-6046 Dual Port RS-232 standard interface (single block) 3 maximum RS-232 Modules per panel 1 Block 60 mA 60 mA 4100-6038 Dual Port RS-232 with 2120 interface (slot module) 1 Slot 132 mA 132 mA 4100-6079 SafeLINC Internet Interface (refer to data sheet S4100-0062 for details) 2 Blocks 145 mA 145 mA 4190-6104 Truelnsight Remote Monitoring Module (refer to data sheet S4100-0063 for details) Side Mt. 62 mA 73 mA 4100-6101 Physical Bridge, Class B, includes 1 modem module and 2 wired modules 1 Slot 210 mA 210 mA 4100-6102 Physical Bridge, Class X, includes 2 modem and 2 wired modules 2 Slots 300 mA 300 mA 4100-6048 VESDA Aspiration System Interface (refer to data sheet S4100-0026 for details) 1 Slot 132 mA 132 mA 4100-6080 DACT, Point or Event Reporting; 1 shipped unless 4100-7908 is selected; 2 max. per system; includes 2, 2080-9047 cables, 14 ft (4.3 m) long, RJ45 plug and spade lugs Side Mt 30 mA 40 mA Additional Enhanced Power Supplies, Expansion Power Supply, and Accessories (for additional non-addressable Power Supplies, refer to data sheet S4100-0031) Model Voltage/Listing Description Size Supv. I Alarm UL & Expansion EPS with IDNet 2 Module; 9 A Expansion Power I 4100-5311 120 VAC ULC Supply (EPS) with battery charger, electrically isolated 250 point IDNet 2 Module, three Class B IDNAC SLCs, one 2 A output 4 Blocks Right 225 mA 490 mA configurable for Auxiliary Power or Simple NAC operation, and Side add IDNet device 4100-5313 220-240 VAC UL expansion slot for City Circuit or Alarm/SupvlTbl Relay option; 120 currents separately VAC model has selectable low battery cutout 4100-5325 120 VAC UL & ULC Enhanced Power Supply (EPS); 9 A EPS, functionally identical to the Expansion EPS except without the IDNet 2 Module 4 Blocks Right Side- 125 mA 220 mA 4100-5327 220-240 VAC UL 4100-5101 120 VAC UL Expansion Power Supply (XPS); 9 A output, 3 built-in Class A/B conventional (non-addressable) 3 A NACs that can 120 VAC , 4100-5103 Canadian ULC also be selected as 2 A auxiliary power output, 2 A separate 2 Blocks 50 mA 50 mA auxiliary power output; without battery charger; Canadian model has low battery cutout 4100-5102 220-240 VAC UL 4100-5115 NAC Expansion Module, 3 NACs, Class A/B, mounts on XPS only N.A. 25 mA 25 mA Dual Class A IDNAC Isolator (DCAI), converts a single Class B IDNAC SLC input to two Class A or two Class B SLC outputs; provides short circuit isolation between 4100-6103 each Class A or B output circuit; connect up to two DCAI Modules per IDNAC SLC 1 Block 8.3 mA 18.5 mA input up to a maximum of 6 DCAI Modules per EPS; each isolated output SLC used requires one IDNAC address; the total current remains controlled by the Class B input source SLC at 3 A maximum 4100-5152 12 VDC Power Option, 2Amaximum 1 Block 1.5Amaximum 4100-0156 8 VDC Converter, required for multiple Physical Bridge Modules, 3 A maximum 1 Block included w/loads 4100-0636 Box Interconnection Harness Kit (non-audio); order one for each close-nippled cabinet 4100-0638 4100 Slot Module Additional 24 VDC Harness; need when 4100 Slot module requirements exceed 2 A from EPS System Option for Seismic Compliance Model I Description 4100-7912 System option for Seismic compliance, provides additional stabilizer brackets required for legacy style cards Module Selection is continued on next page S4100-0100-13 1/2016 rrnr.-rri rn(.1l1rw(.Ii7Tm1iIJij Addressable Interlace Modules (Note: Total of initiating SLCs per CPU, including VESDA Interface, is ) Model Description Supv. Alarm IDNet 2 Module, 250 point capacity; electrically isolated output with two short no devices 50 mA 60 mA 41003109* circuit isolating Class B or Class A output loops, 1 block; standard on EPS with 50 devices 90 mA 150 mA lDNet2 Module; alarm currents for 50 and above devices includes 20 device 125 devices 150 mA 225 mA LEDs in alarm 250 devices 250 mA 350 mA IDNet 2+2 Module, 250 point capacity; electrically isolated output with four short no devices 50 mA 60 mA circuit isolating Class B or Class A output loops, 1 block; mounts in expansion 50 devices 150 mA 90 mA 41003110* bay or available master controller bay module locations only, not applicable for 125 devices 225 mA 150 mA EPS mounting; alarm currents for 50 and above devices includes 20 device LEDs 250 mA in alarm 250 devices 350 mA IDNet Short Circuit Isolating Loop Output Module; mount up to two on a 4100-3109 module; for use with 41003111* 4100-3109 modules in expansion bays or available master controller bay module locations only; not applicable for mounting on a 4100-3109 mounted on an EPS; this option is for aftermarket field installation only Four Loop IDNet Master Controller; for the Master Controller Assemblies listed on page 6, this option moves the 4100-3112 standard IDNet 2 Module from the Master Controller EPS to an available block space in the master controller bay and adds 2,4100-3111 IDNet Loop Output Modules; requires selection of Factory Built Option 4100-7905; current requirements remain the same *Note: Loading per IDNet device (no LEDs on) = 0.8 mA supervisory and 1 mA alarm. Each IDNet 2 and IDNet 2+2 Short Circuit Isolating Loop Output can be individually controlled for system diagnostics and can be assigned a public point for Fire Alarm Network annunciation. Relay Modules; Nonpower-limited (for mounting in expansion bay only, refer to location reference on page 10) Model 4100-3202 Description 4 DPDT w/feedback Resistive Ratings 10 A @ 250 VAC Inductive Ratings 10 A @ 250 VAC Size 2 Slots Supv. 15 mA Alarm 175 mA 4100-3204 4 DPDT w/feedback 2 A @ 30 VDCNAC 1/2 A @ 30 VDC/120 VAC 1 Block 15 mA 60 mA 4100-3206 8 SPDT 3 A @ 30 VDC/120 VAC 1-1/2 A @ 30 VDC/120 VAC 1 Block 15 mA 190 mA Current Calculation Notes: To determine total supervisory current, add currents of modules in panel to base system value and all external loads powered by panel power supplies. 0 To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel SLC and NAC loads and all external loads powered from panel power supplies. End User Programming Software (requires 4100-8802) Model I Description 4100-8802 Programming Software (select) End User Programming Software Selection (select maximum of one each from below) Model Description 4100-0292 Custom Labels Editing; allows editing of 40 Character Custom Labels for non-system user points Access Level/Passcode Editing; allows user to re-assign Access Levels and Passcodes for each display function; 4100-0296 Acknowledge, Alarm Silence, System Reset, Point Enable/Disable, WALKTEST Enable/Disable, Clear History Logs, Change Time & Date, etc. 4100-0295 Port Vectoring Setup and Control; Allows vectoring of events to PC Annunciator, Printers, LCD Annunciators, etc. WALKTEST Configuration Setup and Control; Allows user to create or edit WALKTEST groups used to test-system 4100-0298 initiating devices and signals by a single person, these groups allow an inspector to conduct a one-person WALKTEST in a specific area of a building (or different buildings), and limit the activation of the building signals to only the intended area; up to 8 WALKTEST groups are supported Miscellaneous Accessories Model 4100-1279 Description Single blank 2" display cover; 4100-2302 provides a single plate for a full bay 4100-9835 Termination and Address Label Kit (for module marking); provides additional labels for field installed modules 4100-9856 4100ES Canadian French Appliqué Kit; Simplex, 4100ES, Controle Incendie 4100-9868 Special Purpose Appliqué Kit: Simplex, Elevator Recall Control and Supervisory Control Unit, 4100ES 4100-9869 Special Purpose Appliqué Kit: Simplex, Sprinkler Waterfiow and Supervisory Station, 4100ES 4100-6029 Smoke Management Application Guide; required for UUKL listing 4100-6034 Tamper Switch, one per cabinet assembly if required; monitors solid door for panels with solid door; monitors the internal retainer panel for panels with glass door (not the glass door); has a built-in addressable IDNet lAM 2081-9031 Series resistor for WSO, lDCs (NO. water flow and tamper on same circuit, wires after water flow and before tamper) 470 C), 1 W, encapsulated, two 18 AWG leads (0.82 mm2 ), 2-1/2" Lx 1-3/8" W x 1" H (64 mm x 35 mm x 25 mm) 8 S4100-0100-13 1/2016 S C General Specifications 120 VAC Models 4.6 A maximum @ 102 to 132 VAC, 50/60 Hz Enhanced Power Supplies (EPS) 220-240 VAC Models 2.3 A maximum © 204 to 264 VAC, 50/60 Hz; separate taps for 220/230/240 VAC Battery Input Rating 12 A maximum @ 24 VDC (during battery operation) Input Power 120 VAC Models 4 A maximum © 102 to 132 VAC, 60 Hz Expansion Power Supplies (XPS) 220-240 VAC Models 2 A maximum © 204 to 264 VAC, 50/60 Hz; separate taps for 220/230/240 VAC 9 A output for "Special Application" appliances Total Power Supply Note: The 9 A output rating of the EPS was determined Output Rating such that optional module currents, and external device and appliance currents can be directly added together, not to exceed 9 A total. Output switches to 3 A, regulated 29 VDC during Alarm, 127 addresses, 139 Power Supply Output IDNAC SLC Ratings unit loads; DC-DC converter circuit is >92% efficient over battery backup Ratings for EPS operating range during mains AC failure or brownout Output terminals are rated for 18 to 12 AWG with duplicate conditions output terminals rated for two wires each, allowing up to IDNAC SLC Wiring four (4) Class B branch circuit T-taps to be made in the cabinet; additional T-taps may be made in external wiring junction cabinets or boxes 2Amaximum, 24 VDC nominal (19.5 to 31.1 VDC) Auxiliary Power Tap Compatible Special Application Appliances Simplex TrueAlert ES and TrueAlert addressable notification appliances; contact your Simplex product representative for compatible appliances Battery Charger Battery capacity range UL listed for battery charging of 6.2 Ah up to 115 Ah (batteries larger than 50 Ah Ratings for EPS require a remote battery cabinet); ULC listed for charging up to 50 Ah batteries (sealed lead-acid Charger characteristics Temperature compensated, dual rate, recharges depleted batteries within 48 batteries) and performance hours per UL Standard 864; to 70% capacity in 12 hours per ULC Standard S527 Including module currents and auxiliary power outputs; Total Power Supply NAC outputs are rated 9 A output for "Special Application" Power Supply Output Ratin g "Regulated non-addressable appliances; 4 A output for 24 Output switches to Output Ratings for DC" power (see details below); 6 A output with each NAC battery backup XPS (nominal 28 VDC selected as auxiliary power output during mains AC on AC; 24 VDC on Auxiliary Power Tap battery backup) failure or brownout conditions 2 A maximum I 2Amaximum per NAC; NACs Programmed for Rated 19.1 to 31.1 VDC Auxiliary Power 5 A maximum total Special Application I Simplex horns, strobes, and combination horn/strobes and speaker/strobes (contact your Simplex product Appliances representative for compatible appliances) Regulated 24 DC Appliances Power for other UL listed appliances; use associated external synchronization modules where required Operating Temperature 132° to 120°F (0° to 49° C) Environmental Operating Humidity [Up to 93% RH, non-condensing @ 90° F (32° C) maximum Additional Technical Reference Description Document Description Document ES Installation Instructions 574-848 IDNet 2 and 2+2 Module Installation Instructions 579-1169 ES Operating Instructions 579-197 EPS Installation Instructions 579-1015 DCAI Module Installation Instructions 579-1029 S4100-0100-13 1/2016 S Expansion Bay Module Loading Reference S Slot Slot Slot Slot slot slot Slot slot Block A Block C Block E Block G Block B Block D Block F Block H I Expansion Bay Chassis I Size Definitions: 1 Block = 4" W 5.65" H (102 mm x 144 mm); (often called 4 x 5 modules) 1 Slot 2"Wx 11.3' H(51 mm x 287 mm), typically a motherboard with daughter card Mounting and CPU Bay Module Reference (* indicates supplied modules) One 2" card: either 4100-6078 Network Module with media cards or 4100-6038 RS-232/2120 Interface rMaster Controller Bay I = 4100-6030 Service Modem mounts only on master controller board Space for two 2 slot modules, or one 4" slot modules, or two single 4f : I Knockout Cabinet height: 41006031 or 4100-6032 block modules, or one : II screw/nail (2 bay shown double block (vertical City Circuit or 41006033 holes (for for reference) ___ Relay Module mounts on semi-flush mount) module . , H bottom of EPS mountin I Bay = 22" g (559 mm) Optional 4100-6049 . 2 Bay = 40' Truelnsight Module 4100-6080 DACT - \ r. (1016 mm) mounting location mounting location j/ F *p power supply 1 Exposed cabinet for ' - 3 Bay = 56" [with !DNet2moduleJ semi-flush mounting (1 22 mm) 1*Master controller 1 1/2" (12.7 mm' with motherboard f " minimum / Wall board 1 Typical Expansion Bay L it i it i it i ii reference for I L(Showng mixed module sizes)f -J_J I semi-flush DI Fi I 111111' "-' mounting, Ill 1 1 I 6" stud Two bay cabinet shown I I I H I Stud without dress panel ..-- - alignment h side tud Battery Compartment (121 mm) (50 Ah maximum) Door can be hung [32hinged left or right —24" (610 mm, - Optional semi-flush trim kit 1111/16" (296 mm) I NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. 10 S4100-0100-13 1/2016 S TrueAlert ES Appliance Self-Test Last Test Results Report Example Service Port Page 1 REPORT 10 TrueAlertES Self-Test Report 12:34:56pm WED 03-DEC-14 Point ID Custom Label Date Visual Audible Ti-i-1 VO FIRST FLOOR (up to 40 characters) 03-DEC-14 NO OUT N/A T1-2-5 AV FIRST FLOOR EAST WING 03-DEC-14 NO OUT NORMAL T7-3-55 AO SECOND FLOOR EAST WING 03-DEC-14 N/A NO OUT T8-2-45 AV SECOND FLOOR ROOM 29 03-DEC-14 NOT TST N/A T8-2-60 AV SECOND FLOOR ROOM 22 03-DEC-14 NORMAL NORMAL T1-2-4 AO FIRST FLOOR ROOM 17 03-DEC-14 N/A UNSUPP TRUEALERTES SELF-TEST REPORT COMPLETED Press RETURN for next Screen OR CTRL-X to abort Results Description: NORMAL = works correctly NO OUT = No Output, no light or sound was detected NOT TST = no result; either the appliance did not return a result before the test ended or the test was conducted as silent (strobes only) and audible appliance was not activated N/A = not applicable (no strobe on audible only, etc.) UNSUPP = appliance not compatible with Self-Test (TrueAlert addressable appliance not TrueAlert ES addressable appliance) Note: Additional TrueAlert ES Self-Test information is detailed in ES Operating Instructions 579-197 shipped with the panel. TrueAlert ES Appliance Self-Test All Test Results Report Example Service Port REPORT 10 TrueAlertES Self-Test Report 12:34:56pm Page 1 WED 03-DEC-14 Point ID Custom Label Date Visual Audible Ti-i-1 VO FIRST FLOOR 03-DEC-14 NO OUT N/A T1-2-5 AV FIRST FLOOR EAST WING 03-DEC-14 NO OUT NORMAL T1-2-6 AV FIRST FLOOR NORTH ENTRANCE 30-OCT-14 NO OUT NORMAL T7-3-55 AO SECOND FLOOR EAST WING 03-DEC-14 N/A NO OUT T8-2-45 AV SECOND FLOOR ROOM 29 03-DEC-14 NOT TST N/A Ti-i-li AV FIRST FLOOR SOUTH ENTRANCE 30-OCT-14 NORMAL NORMAL T8-2-60 AV SECOND FLOOR ROOM 22 03-DEC-14 NORMAL NORMAL T1-2-4 AO FIRST FLOOR ROOM 17 03-DEC-14 N/A UNSUPP Tl-2-7 AO FIRST FLOOR ROOM 12 30-OCT-14 N/A UNSUPP T8-3-43 AV SECOND FLOOR ROOM 25 30-OCT-14 UNSUPP UNSUPP TRUEALERT_ES SELF-TEST REPORT COMPLETED Press RETURN for next Screen OR CTRL-X to abort TrueAlert ES Appliance Self-Test Individual Appliance Report Example CUSTOM LABEL 4-1-2 POINT ADDRESS: 4-1-2 CARD:4 CHANNEL:1 DEVICE:2 EXTENDED POWER SUPPLY UNIT NUMBER: 2 AV Type: AV RUI NUMBER: LOCAL PRIMARY STATUS NORMAL AUDIBLE GROUP CONFIG: 000 VISUAL GROUP CONFIG: 000 STYLE: INDOOR OPERATION: GENERAL EVAC CANDELA RATING 15CD COLOR LENS YES TONE TYPE BROADBAND CODING TYPE TEMPORAL VOLUME HIGH LAST TEST TIME: MON 02-JUN-14 01:00 AM LAST VISUAL TEST: NORMAL LAST AUDIBLE TEST: NORMAL LAST TEST VOLUME: NORMAL DEVICE TEST TROUBLE: NORMAL 11 S4100-0100-13 1/2016 Additional 4I00ES Data Sheet and Related Product Reference E Subject Introducing the 4100ES Data Sheet S4100-0060 Subject Fire Alarm Network Overview Data Sheet 54100-0055 4100ES Enclosures S4100-0037 Network Communications S4100-0056 4100ES Audio and Firefighter Phone Modules S4100-0034 Network Display Unit (NDU) S4100-0102 LED/Switch Modules & Printer S4100-0032 Addressable Device Compatibility S4090-0011 Remote Annunciators S4100-0038 4009 IDNAC Repeater S4009-0004 MINIPLEX Transponders S4100-0103 Remote Battery Charger S4081-0002 Building Network Interface (BNIC) S4100-0061 SafeLINC Internet Interface S4100-0062 lnfoAlarm Command Center S4100-0101 4100ES Panels for Conventional Notification S4100-0031 Graphic I/O Modules S4100-0005 TrueAlarm Sensors S4098-0019 lruelnsight Remote Service S4100-0063 Remote lDNet Isolator S4090-0005 Agent Release Applications S4100-0040 TrueAlami IDNet Isolator Base S4098-0025 TrueAlert ES Audible Only Appliances S49AO-0001 TrueAlert ES Weatherproof Appliances, UL Listed S49WP-0001 TrueAlert ES Visible Only Appliances S49VO-0001 TrueAlert ES Weatherproof Appliances, ULC Listed S49WP-0002 TrueAlert Appliance/IDNAC SLC Isolator S4905-0001 TrueAlert ES Emergency Communications Appliances with Color Lenses S49LENS 0001 TrueAlert ES Audible/Visible Appliances S49AV-0001 TYCO, SI]vIPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited VESDA is a trademark ofXtralis Ply Lid. NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association (NFPA)- ASHRAE and BACnet are trademarks ofASHRAE, American Society of Heating, Refrigeration, and Air Conditioning Engineers. 0 J3.SiM pJ1EX Tyco Fire Protection Products• Westminster, MA • 01441-0001 USA S4100-0100-13 112016 www.simplex-fire.com 0 2015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7165-0026:0251 Page 1 of 4 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Simplexlo0 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4100-9111,-9112,-9113,-9114,-9115,-9116,-9121,-9122,-9131,-9132,-9133, -9211, -9212, -9213, -9222, -9230, -9311, -9312, -9313, -9314, -9315, -9316, -9331, -9332, -9511, -9512, -9513, -9600, -9601 and -9602 fire alarm control units. Power limited, automatic, manual, local, auxiliary, remote station, proprietary and central station, process monitoring, smoke control system, smoke detector monitor, emergency communication and relocation, waterflow and sprinkler supervisory service. Suitable for releasing device service. Models 4100-9111,-9112,-9113,-9114,9115,-9116,-9121,-9122,-9211,-9212,-9213, -9222, -9311, -9312, -9313, -9314, -9511, -9512 and -9513 suitable for mass notification system as an autonomous control unit. The network display units are suitable for mass notification system system as a central control station. The remote annunciators are suitable for mass noticication system system as a local operating console. Refer to listees data sheet for detailed product description and operational considerations. System components: 4100-7101, -7104, -7113, -7115: Master Controller Assembly 4100-7105: Redundant Master Controller Assembly 4100-7150, -7151, -7152-7154-7156, -9833: Master Controller Replacements 4100-5005, -5015: 8-Point Class A IDC Module 4100-1291: Remote Unit Interface Module 4100-3102,-9812-. MAPNET II Module 4100-3103: MAPNET/IDNET Isolator Module 4100-6038 RS-232/2120: Communication Module 4100-6014-6078: Modular Network Interface Module 4100-1293: Printer 4100-6052-6080: Event Reporting DACT 4100-6053: Point reporting DACT 4100-6067: Contact Closure DACT 4100-6031, -6032, -9827, -9828: City Module 4100-2300,-2320: Expansion Bay 2975-9408 thru -9412: Backbox 2975-9438 thru -9440: Backbox 4100-2101 thru -2103, -2121 thru -2123: Glass Door and Retainer 4100-2104 thru -2106, -2124 thru -2126: Glass Door and Retainer *Revision 10-18-16, 2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 2 of 4 4100-2111 thru -2113, -2131 thru -2133: Solid Door 4100-2114 thru -2116, -2134 thru -2136: Solid Door 2975-9422 thru -9426, -9428, -9429: Enclosure 2975-9431, -9432: Enclosure 2975-9441 thru -9452: Enclosure 4100-0633, -6034: Tamper switch 4100-9141-9142-9151-9152-9241 thru -9246,-9342,-9352,-9542 Network Display Unit 4100-6030,-6055: Service Modem 4100-5101, -5102, -5103: Expansion Power Supply 4100-5111, -5112, -5113: System Power Supply 4100-5125, -5126, -5127: Remote Power Supply 4100-1288,-1289: LED/Switch Controller 4100-1275 thru -1287, -1295, -1299: LED/Switch Module 4100-1300, -1301, -1302: LED/Switch Module 4100-1290 24: Point Graphic I/O Module 4100-9607-9609-9610, -9611-9612-9614-9615 Remote Annunciator 4100-1292: Remote LCD Display 4100-3115: XA Loop Interface Module 4100-3101-3104, -3105, -3106, 3107,3108*3109,*3110,*3111,9811 IDNET Module 4100-9116: Addressable I DNET Isolator 4090-9117: Addressable Power Isolator 4100-9643: Utility Cabinet 4100-0634, -0635: Power Distribution Module 4100-5152, -5153, -5154, 5155: Auxiliary Power Supply 4100-6033, -9829: Alarm Relay Card 4100-3201, -3202-3203-3204-3206: Auxiliary Relay Modules 4100-0620: Basic Transponder Interface Card 4100-6043, -6044: Converter 4100-6045: Decoder Module 4100-6054: Fiber Optic Driver 4100-5115: Expansion NAC 4100-9816: Master Clock Interface 4100-6048: VESDA Interface 4100-5311-5313 -5325 -5327: Extended Power Supply 4100-6103: Dual Class A Isolator 4100-5120, -5121, -5122: True Alert Power Supply 4081-9306, -9308: Expansion Battery Charger 4100-2140: Rack Mount Bay Mounting Kit 4100-2144: Rack Mount PDM Mounting Kit 4100-0156: Eight Volt Converter 4100-0625: Local Mode Transponder Interface Card 4601-9100, -9108,-9109,-9110,-9111 Local Mode Controller 4100-0623: Basic Network Transponder Interface Card 4100-0621, -0622, -1341 :Audio Riser Module 4100-6036, -6037-6101-6102: Physical Bridge Assembly *Revision 10-18-16, 2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S Listing No. 7165-0026:0251 Page 3 of 4 • 4100-9849, -9863: TCP/IP Physical Bridge Assembly (Style 4) 4100-9850, -9864: TCP/IP Physical Bridge Assembly (Style 7) 4100-6056: Wired Media Card 4100-6057: Fiber Optic Media Card 4100-9620 : Analog Audio Expansion Bay 4100-9621 : Digital Audio Expansion Bay 4100-1210 : Analog Audio Controller Card 4100-1211, -1311: Digital Audio Controller Card 4100-1212 thru -1225, 1261, -1262 Analog Audio Amplifier 4100-1312 thru -1325, -1361, -1362 Analog Audio Amplifier 4100-1226 thru -1239, 1263, -1264 Digital Audio Amplifier 4100-1326 thru -1339, -1363, -1364 Digital Audio Amplifier 4100-1240: Audio Input Option Card 4100-1241, -1242: Message Expansion Card 4100-1243, -1244: Microphone Module 4100-1245, -1248, -1266: Amplifier Expansion NAC 4100-1246, -1249, -1267: Amplifier Class A Adapter 4100-1252, thru -1255 Audio Operator Interface Module 4100-1270: Master Telephone Assembly 4100-1271 : Remote Telephone 4100-1272: Expansion Phone Card 4100-1273: Telephone Class A Adapter 4100-5116: Expansion Signal Card 4100-1259, -1260, -1268: Constant Supervision NAC Modules 4100-1265: Degrade Fail-Safe Microphone Module 4100-6068'. TFX Interface Module 4100-6072, 6073, 6074, 6075: Fiber Optic Modem9402 4100-9842: Fiber Modem Audio Expansion Board S 4100-9901 thru -9926, -9930 thru -9939Retro-fit Kits 4100-7153, -7155: Display Replacement 4100-9401, *.9403 *.9423 -9441, *9443. Remote User Interface 4100-0640: FUI Controller Memory Add-on Module 4100-7157: Expanded Memory CPU Card 4100-6065: BMUX Communication Card 2081-9046: Coil Supervision Module 4100-6066: TFX Loop Card 4100-5130: TFX Voltage Regulator Module 4100-1340 : TFX Audio Interface Module 4100-1297: TFX Phone Card 4100-1298: TFX Master Telephone with Phone Card 4100-6069: BACpac Ethernet Module 4100-1274: Microphone Multiplex Module 4100-6047: Building Network Interface Card 4190-6104: Remote Service Gateway RATING: 120, 220, 240 VAC primary; 24 VDC secondary *Revision 10-18-16. 2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 4 of 4 INSTALLATION: In accordance with listees printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. is MARKING: Listees name, model/catalog number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units suitable for use with separately listed compatible initiating and indicating devices. Also Suitable for high-rise applications. The control unit is compatible with the Model 4090-9007Signal Individual Addressable Module (CSFM Listing No. 7165-0026:318). These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification feature (delay of the fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Combined from 7170-0026:250 S *Revision 10-18-16, 2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division n fiSimplEx UL, ULC, CSFM Listed,- FM Approved* II1JI*1 4009 IDNAC Repeaters provide enhanced power delivery to TrueAlert/TrueAlert ES addressable notification appliances controlled by IDNAC SLCs: Output voltage is maintained by efficient switching regulator at 29 VRMS during both AC and battery backup conditions allowing strobes to operate at lower current With lower current strobes and regulated output voltage, wiring distance can be extended 2 to 3 times that of conventional notification, appliance loading can be increased, or smaller wire gauge can be used, all resulting in installation savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions 4009 IDNAC Repeaters receives an IDNAC SLC input and provide a repeated 3 A SLC output to extend SLC distance and power: Appliance control remains with the host IDNAC control panel and Repeater operation is essentially transparent; Repeater status is communicated to the control panel for system diagnostics and also locally indicated Input SLC connection can be Class B or Class A Repeater output can be a Class A loop or a Class B output with internal connections for up to four (4) T-tapped output branches (Class A output requires 4009-9814 Class A Adapter) Operation requires one IDNAC SLC address; Repeaters can be connected as one in series, or up to five (5) in parallel AC power input is 120 VAC or 220-240 VAC, 50/60 Hz, auto-select An on-board battery charger is provided with low AC battery disconnect selectable per Repeater (required for ULC listed applications) Operation is compatible with TrueAlert ES and TrueAlert addressable notification appliances and accessories Available with platinum or red cabinet Listed toUL864 and ULC S527 Multiple wiring options are available: Wiring options include Class B multiple branch (up to 4) output, Class A loop extension, and Class A riser to Class B branches or a Class A loop output When the Repeater is part of a Class A loop from the IDNAC SLC source panel, up to twice the distance for the loop is available; (Class A loop repeating requires 4009-9814 Class A Adapter) Class A Adapter 4009-9814: Required when extending a Class A loop or to provide a Class A local loop SLC output Operation provides short circuit isolation between input and output terminals for improved IDNAC SLC survivability TrueAlert Addressable Notification 4009 IDNAC Repeater; Power and Distance Extender 'FIRE' Extended distance and current Fine Repeated IDNAC SLC 4009 IDNAC Repeater FIRE __ II FIRE IDNAC SLC 4100ES with EPS Power Supply 4009 IDNAC Repeater Extends Distance and Current of IDNAC SLC Features (Continued) Built-in battery Charger Power supply charges up to 12.7 Ali batteries for in cabinet mounting and up to 25 Ali batteries with model 4009-9801 external battery cabinet Available auxiliary output: A 200 mA, 29 VDC constant auxiliary output is available; operation is maintained during battery backup * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0375 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4009-0004-2 7/2013 IrnrTWTlT1 Repeating IDNAC SLCs. 4100ES fire alarm control panels with an EPS or EPS+ (enhanced power supply) provide individual address and control of TrueAlert and TrueAlert ES addressable notification appliances using IDNAC SLCs. When an IDNAC SLC reaches the current limit or the distance limit of the source IDNAC SLC, use of 4009 IDNAC Repeaters extends the IDNAC SLC with an additional 3 A of SLC current. With IDNAC SLCs, a constant 29 VRMS source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. strintir Three wiring configurations are available to provide a variety of system solutions: Class B branch extension, Class A loop extension, and Class A riser to Class B branch extension or Class A loop output. 114-I Class B branch input wiring allows T-tapped connections to up to five (5) parallel connected 4009 IDNAC Repeaters. Each Repeater has on-board output terminal connections for up to four (4) output branch circuits, and additional branch circuits can be externally T-tapped as required. (Refer to diagram on page 3 for additional details.) Class A loop extensions use a single 4009 IDNAC Repeater to extend the current and distance of a single Class A loop allowing the loop distance to be doubled. The Repeater communicates and repeats bi-directionally allowing Class A loop operation to be maintained in the event of an open circuit. This wiring connection requires use of the 4009-9814 Class A adapter. (Refer to diagram on page 4 for additional details.) Class A Riser to Class B Branches or Class A Loops. For applications requiring a combination of wiring types, a Class A riser can drive up to five (5) 4009 IDNAC Repeaters with each Repeater capable of driving either single or multiple Class B branch output(s) or a Class A loop output. In this wiring application, the Repeater does not repeat in the Class A riser loop, it is connected as an appliance with Class A in/out wiring. To create a Class A loop output, the Repeater must be equipped with a 4009-9814 Class A Adapter. (Refer to diagram on page 5 for additional details.) I1tr1 Model Cabinet Color Description 4009-9601(BA) Platinum 4009 IDNAC Repeater with cabinet; provides a single 3 A IDNAC SLC output, 200 mA auxiliary 4009-9602(BA) Red power output, and battery charger; 120/240 VAC, 50/60 Hz input, auto-select * Add suffix BA to select 4009 IDNAC Repeaters assembled in the USA. Aftermarket Accessories (installed on-site, select per system requirements) Model I Description 4009-9814 Class A Adapter Module, mounts on repeater controller board; required for Class A output 2975-9813 Platinum semi-flush box trim 1 /16" (37 mm) wide, four corners and trim pieces for top, bottom, and sides; (will 2975-9812 Red semi-flush box trim need to be cut to fit 4009 IDNAC Repeater cabinet) External Accessories (select per system requirements) Model Description Comments 4905-9929 Remote TrueAlert Communications Isolator I Refer to data sheet S4905-0001 for details 4009-9801 External Battery Cabinet for 25 Ah batteries 116 %" W x 13 %" H x 5 %" D (413 mm x 343 mm x 146 mm); refer to data sheet S2081-0006 for details Battery Selection (select battery size per system requirements; two batteries are required for 24 VDC operation) Model Description Model Description 2081-9272 6.2 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC Requires 4009-9801 External Battery Cabinet 2081-9274 10 Ah Battery, 12 VDC 2081-9287 25 Ah Battery, 12 VDC 2081-9288 I 12.7Ah Battery, 12VDC II 1 I S4009-0004-2 7/2013 S Wiring Reference, Class B Input with Class B Branch Circuit Outputs 4009 IDNAC Repeaters Class B Branch Extensions - (5 maximum) IDNAC SLC input / IDNAC SLC output FIRE FIRE Class B IDNAC SLC Class B IDNAC SLC - - - - - - Class B wiring can PR FIRE 41 OOES with EPS PIR -- be "T -tapped" Power Supply Class B IDNAC SLC S Wiring Notes: Up to five (5) 4009 IDNAC Repeaters can be wired in parallel as shown on this diagram. IDNAC SLC communications can be repeated only once between the source and the addressable appliance. The 4009 IDNAC Repeater extends distance and current of the input IDNAC SLC; it requires one address and consumes four (4) unit loads. iw~~6 Class B IDNAC SLC FIRE Class B IDNAC SLC S Each 4009 IDNAC Repeater has duplicate output terminals rated for two wires each, allowing up to four (4) Class B branch circuit T-taps to be made in the cabinet; additional T-taps may be made in external wiring junction cabinets or boxes r T FIR -EE 0 —J 1-$-5S-1 MMM SOME ping PIR - Class B IDNAC SLC Branch Circuits 3 S4009-0004-2 712013 Wiring Reference, Class A Loop Extension Class A IDNAC SLC Loop with 4009 IDNAC Repeater Extending Loop Range and Power 4009 IDNAC Repeater Requires optional 4009-9814 Class A Adapter Module set for Loop mode 1- Class A loop secondary direction p111. 1 Id C - Class A loop primary direction L1HLJ- fW LI1I Class A loop secondary direction 4100ES with EPS Power Supply, requires optional 4100-6103 Dual Class A IDNAC Isolator (DCAI) Notes: Only one 4009 IDNAC Repeater can be wired in a Class A loop. (IDNAC SLC communications can be repeated only once between the source and the addressable appliance.) The 4009 IDNAC Repeater extends distance and current of the Class A IDNAC SLC loop; it requires one address and consumes four (4) unit loads. Under normal operating conditions (no open circuit wiring), appliances 1 through 4 are powered by the 4100ES EPS Power Supply and appliances 5 through 9 are powered from the 4009 IDNAC Repeater. Under open circuit conditions, an open circuit in the panel side of the primary path will result in the 4100ES EPS Power Supply powering appliances 5 through 9 and the 4009 IDNAC Repeater will receive IDNAC SLC input from the return path and then power appliances 1 through 4, or as many as remain connected. 4 S4009-0004-2 7/2013 Wiring Reference, Class A Riser Input with Class A Loop and Class B Branch Outputs 4100ES with EPS Power Supply, requires optional 4100-6103 Dual Class A IDNAC Isolator (DCAl) Requires optional 4009-9814 Class A Adapter Module set for Branch Mode to create a local Class A loop circuit output Class A Loop Extension IDNAC SLC input t J, TT Class Loop IDNAC SLC shown as a Class A Riser with each IDNAC Repeater wired in/out (not T-tapped); 101 only two (2) are shown, maximum is five (5) 4009 IDNAC Repeaters Class B Branch Extension Wiring detail reference (repeaters - are wired same as appliances) S 4009 IDNAC Repeater Mounting and Module Placement Reference 16-114" (413 mm) ',I 0-29/32" (277 777 • Door, 5/8" (16 mm) thick Exposed cabinet dimension for semi-flush mount 1" (25.4 mm), 1-3/8" (35 mm) with semi-flush trim Cabinet depth 4-1/8" (105 mm) 0 13-1/2" (343 mm) Knockouts for screw or nail mounting holes ------------------------------------------ 12(305mm) Batte location (doffed line) no conduit ent or wiring in this area, 127 Ah maximum ! 0 1-3/16" wide (30 mm), [j Shaded Area is Non-power limited Optional Semi-Flush Trim Kit -.. 3/8" (9.5 mm) thick Wall surface reference for semi-flush mount L S4009-0004-2 7/2013 4009 IDNAC Repeater Specifications Input Ratings Voltage Range 120 VAC, 50/60 Hz, or 220/230/240 VAC, 50/60 Hz, +10%, -15%, auto-select AC Input Ratings 120 VAC Current 2.5A 220/230/240 VAC Current 1.25A Panel IDNAC Appliances Auxiliary Load 70 mA 0.8 mA each Output current (voltage is from battery) Standby Currents 24 VDC Requirements for Battery Calculations 4.5 A maximum with 3 A IDNAC SLC load 1.37 x output current Alarm Currents 96 mA and 200 mAAuxiliary output load (actual (voltage converter is on alarm current depends on connected and when in Alarm) activated appliances and devices) 17 VRMS minimum IDNAC Input Ratings 1 address, 4 unit loads Output Ratings IDNAC SLC Output 3 A maximum @ 29 VRMS for Special Application appliances Compatible Special Application Appliances Simplex TrueAlert ES and TrueAlert addressable notification appliances; contact your Simplex product representative for compatible appliances IDNAC SLC Ratings and Loading Up to 62 total addressable appliances; one address is required for the Repeater Up to 75 total unit loads (appliances are 1 unit load, Repeater and Isolators are 4 unit loads) Up to 62 compatible strobes can be synchronized per IDNAC SLC Current Auxiliary Output Voltage 200 mA maximum 29 VDC nominal with AC present or when Repeater is on battery standby and in Alarm 24 VDC nominal when on battery standby and not in Alarm IDNAC SLC Wiring Specifications (refer to installation instructions for more information) Recommended wire type UTP, unshielded twisted pair Maximum wire length allowed with 10,000 ft (3048 m) "T -Taps" for class _B_wiring Maximum wire length to any appliance 4000 ft (1219 m) Maximum wiring resistance between 26 appliances Wiring Connections Terminal blocks for 18 to 12 AWG Repeater Status Indicators Green AC Power LED On with AC present, off during brownout or no AC condition Red Communications LED (COMM) Blinks when Repeater is communicating with the host control panel Yellow System Status LEDs 4 LEDs provide up to 16 different trouble status indications an on-board trouble scroll button allows review should multiple troubles occur 4009-9814 Class A Adapter Module Option (required for Class A loop extension or for Class A output) IDNAC SLC Output Voltage 3 A maximum © 29 VRMS for Special Application appliances Two connections, Port A and Port B, function varies by application (loop extension or local loop), Port A and Port B are isolated from each other Status LEDs Two yellow trouble LED indicators, one per Port Environmental and Technical Publications Reference Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range Up to 93% RH at 90° F (32° C) Installation 4009 IDNAC Repeater 579-1019 Instructions Class A Adaoter Module 579-1080 TYCO. SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. 0 B Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4009-0004-2 7/2013 www.simplexgrinnell.com © 2013 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. CATEGORY LISTEE: DESIGN: RATING: 7300-0026:0375 Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com Models 4009-9601, 4009-9601 BA, 4009-9602 and 4009-9602 BA IDNAC repeaters. Model 4009-9814 Class A Adapter card. Refer to listee's data sheet for detailed product description and operational consideration. 120V/240V INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an accessory for use with listee's separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. C 04-23-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Remote Battery Cabinets are Available for Larger Battery Requirements I Shipping. Sealed lead-acid batteries are shipped via ground or sea transportation only. They are not shipped via air. Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Seismic Activity Applications. Battery brackets are available for systems tested for compliance with specific batteries. Please refer to data sheet S2081-0019 for details. * Refer to details on page 4 and to the referenced individual product data sheets for agency listing states of battery cabinets and chargers. The batteries detailed in this document meet the requirements of UI. ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S2081-0006-21 12/2014 ØSimplEx Listings* Fire Alarm Control Panel Accessories System Batteries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger I ui*i Rechargeable, sealed lead-acid batteries: Lead-calcium grid structure with immobilized electrolyte in absorbent separator Low maintenance with no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover with high reliability dual seal construction UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size Larger batteries, up to 110 Ah, mount in external battery cabinets with models available with internal chargers Battery cabinets with chargers: Battery cabinets with charger communicate with their connected fire alarm control panel and are available for 4100ES/401OES/4100U Series and 4010 Series panels IRI4-i.i rPti is Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. Where required, external battery cabinets can be close-nippled to the control panel to house larger batteries with battery chargers available in some battery cabinet sizes. 1:;rT1 m171lF1 Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Battery Size Specifications Battery Model Capacity @ 20 Hour Width* Depth*Height with Approximate Discharge Rate Terminals Weight 2081-9272 6.2 Ah 6-1/8" (156 mm) 2-5/8" (67 mm) 4(102mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah 6" (153 mm) 4-1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6' (153 mm) 4" (102 mm) 4" (102 mm) g lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) 5' (127 mm) 7" (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 ("square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9" (229 mm) 5-1/2" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg) 2081-9279 110 Ah 11-3/16" (284 mm) 10-1/2" (267 mm) 9" (230 mm) 82 Lbs.(37 kg) S Battery Construction Reference S Actual appearance will vary with battery size. outer cover Vent hole Polling material, black for (type varies with battery size) Quick connect or post type terminaI negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Inner Absorbent separator used to immobilize electrolyte Semi-permeable Lead-calcium grids V membrane separator Cell group /r 'Iwl~ (k Cell case (high impact polystyrene) * Dimensions and-weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 for mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output, these batteries are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. General Battery Specifications Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60" F to 90" F (15.6"C to 32.2" C) S2081-0006-21 12/2014 C Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Simplex Control Panel Model Series (see legend and notes below) Battery Capaci 4007ES & 4006 & 4009 4100ESI 4100 & 4120 Model 4003EC 4004R 4005 4008 (all models) 4010 401 DES 4100U (2, 4 or 6-Unit) 2081-9272 6.2 Ah 1 1 1 1 1 If 1 1 2081-9274 10 Ah 1 1 1 1 1 1 1 1 1 2081-9288 12.7 Ah 1 If If 1 1 1 1 Jr 1 2081-9275 18 Ah Ext Note 3 1 Ext Ext Note 2 2081-9287 25 Ah Ext Note 3 Ext Ext NA If 2081-9271 33 Ah Ext Note 3 Ext NA NA Note 3 .1 1 Ext rectangular 2081-9276 33 Ah Ext Note 3 Ext NA NA Note 3 1 1 1 "square" 2081-9296 50 Ah NA Note 3 NA NA NA Note 3 Note 6 2 or 3 bay Ext 2081-9279 1 110 Ah Requires external battery cabinet, compatible with 4100ES, 4010ES, 4100, and 4120 Series only 1 = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 NA = Not applicable/not compatible NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. S 4. Some control panel models are listed for battery replacement reference only. 5. For 2 bay international applications only, 50 Ah batteries will fit in the cabinet. [External Battery Cabinet Compatibility Reference Battery Cabinets without Chargers (connects to charger in panel) Battery Cabinet Panel Compatibility 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 18 Ah* 25 Ah Rectangular 33 Ah Square 33Ah 50 Ah 110 Ah 2081 -9280 4100ES, 4010E5, NA NA NA NA NA 1 4100U, and 4100+ 2081-9281 multiple 1 1 1 1 1 NA 2081-9282 4009-9801 multiple 1 1" NA NA NA NA 4009-9802 multiple I NA I NA NA NA Battery Cabinets with Chargers 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 Cabinet Panel Compatibility 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 4081-9301 4004R and 4010 1 1 1 1 1 NA 4081-9302 4081-9306 4IOOES, 401OES, NA NA NA NA I I 4081-9308 and 4100U * Batteries smaller than those listed are normally mounted in the product cabinet ** 25 Ah capacity was effective as of 7/2005. S I = Can be placed in the respective equipment cabinet NA = Not applicable/not compatible S2081-0006-21 12/2014 S Battery cabinet for 2081-9279, 110 Ah 2081-9280 batteries; includes Listings Red 80 A battery fuse, include: UL terminals and and CSFM battery connection cables; see data sheet for details External Battery Cabinet Specification Reference S Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081-9281 Beige UL and FM 2-Unit, 4100 style cabinet without charger; with locking solid door and battery shelf, primarily for use with 50 Ah 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081 -9282 Red batteries 4003-9860 Beige Multiple Intended for use with 4003EC systems, for up to 33 Ah 9-1/2" H x 24" W 9" D batteries (refer to 4003EC data sheet S4003-0002) (241 mm x 610 mm x 229 mm) 40099801* Beige UL and For up to 25 Ah External battery cabinet without charger, 16-1/4" W X 13-1/2" H X 53/4" D FM batteries" I with locking solid door and battery I harness; for close-nippled mounting to (413 mm x343 mm x 146 mm)" For up to 33 Ah 25-3/4" W x 20-3/4" H x 4-1/8" D 4009-9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) * Depth increased for 25 Ah batteries effective 7/2005. Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081-0001) Model Color Input Voltage Description Dimensions Battery cabinet with charger for the 4010 and 4081-9301 Beige 4004R fire alarm control panel; for up to 50 Ah 120 VAC batteries; with front door 22-1/2 Wx16-314 H x 8-3/8 D 4081-9302 Red Listings include: UL, ULC, FM, CSFM, and MEA (572 mm x 425 mm x 213 mm) (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (icier to data sheet S2081-0012) Model & Cabinet Compatible Color Cabt Description Charger Description Dimensions Listings Chargers 4010-9xxx 4010ES Main System Supply I Series (MSS) 4100-9xxx 4100ES/4100U System Power Series Supplies (SPS) 4100-5111 4100-5112 4100ES/4100U Additional SPS 4100-5113 4100-5125 4100ES/4100U Remote Power 4100-5126 Supply (RPS) 4100-5127 4100-5120 4100ES/41001_1 TrueAlert 4100-5121 Addressable Power Supply (TPS) 4100-5122 4100-0104 4100-0114 4100 Legacy power supplies 4100-0124 26-1/2" W 12" H x 12" D (673 mm x 305 mm x 305 mm) 4IOOES/40IOESI4IOOU Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted-power supply charger; refer to data sheet S4081-0002) Model Color Input Voltage Description Dimensions Battery cabinet with charger for up to 110 Ah 4081-9306 Red 120 VAC batteries; NOTE: Required for ULC listed charging of 27-7/8" W 13-1/2" H x 14-5/8" D , ,, 110 Ah batteries; Listings include: UL, ULC, FM, (708 mm x 343 mm x 371 mm) 4081-9308 Red 220/2 0/24 VA C, CSFM, and MEA (NYC), see data sheet for multi-tapped details 4100-9837 Green LED Power-on Indicator Kit, required for ULC listing, mounts above access panel using knockout provided TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. ®S I ni p1 EX Tyco Fire Protection Products' Westminster, MA 01441-0001 USA S2081-0006-21 12/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reset-red All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. E f3SimplEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* I11!i (*1 TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet orMAPNET II two-wire communications For use with the following Simplex® products: 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-S530 General features: Operation is for ceiling or wall mounting Listed to UL 268 and ULC-S529 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMil compatibility Magnetic test feature is provided Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Heal® and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. TrueAlarm Analog Sensing TrueAlarm Analog Sensors - Photoelectric and Heat; Standard Bases and Accessories 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications. with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. S4098-0019-20 1/2015 TrueAlarm Sensor Bases and Accessories I *I Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT): 4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required Supervised relay operation is programmable and can be manually operated from control panel Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay: SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay: Activates when base LED- is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) t3Simplex & E'iPcrrintir, TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. IlVlOUfltlflY rcetereri.e Electrical Box Requirements: (boxes are by others) Without relay in the peA: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay in the box :4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring 4" (102 mm) Square Box 4"(102 mm) Octagonal Box Surface mount reference- - 1-1/2" (38 mm) , I minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 2098-9737 Supervised Relay 4098-9822 Relay (mounts (mounts in base electrical box or in base electrical box) remotely) V Rel.y Siz2-1/2" X 1-1/2" X 1 - _" 3.75 in3) (64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8" X 1-1/4" X 11/32~=f (1 in3)(60.4 mm X 31.8 mm X8.6 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. l 6-3/8" (162 mm) •1 t 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) and 4" square flush box 4-7/8" (124 mm) 15/16" (24 mm) 0 TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 S S S4098-0019-20 1/2015 4fl9R-971 Heat nsnr TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1°C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. T~ 2-3/8' (60 mm) 4098-9733 Heat Sensor with Base TrueAlarm Sensors S I(uIt41 Sealed against rear air flow entry Interchangeable mounting EMIIRFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135' F 60 ftx60 ft 20ftx20 ft (6.1 m) for fixed (57.2' C) (18.3 m) temperature only; RTI = Quick 50ftx50ft(15.2 m) for fixed 155' F 40 ft x 40 ft temperature with either rate-of-rise (68' C) 1 (12.2 m) I selection; RTI = Ultra Fast Smoke Sensors: Photoelectric technology sensing 3600 smoke entry for optimum response Built-in insect screens DI;Y I iTT Fiiisi TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power S smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 3600 smoke entry for WARNING: In most fires, hazardous levels of smoke optimum response to smoke from any direction. Due to its and toxic gas can build up before a heat detection photoelectric operation, airyelocity is not normally a device would initiate an alarm. In cases where Life factor, except for impact on area smoke flow. Safety is a factor, the use of smoke detection is highly recommended. 1 F -4-7/8" (124 mm) LED status indicator / 2-1/8" '\ (54 mm) \ I liii I IT III 4098-9714 Photoelectric Sensor with Base Annlirtinn RpfprpnrpM Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. S4098-0019-20 1/2015 S I 17T1 F1 \ TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) \ (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model Description I Compatibility Mounting Requirements 4098-9792 Standard Sensor Base No options depth; or single gang box, 2" min. depth 4" octagonal or 4" square box, 1-1/2" min. N Sensor Base with connections for 2098-9808 Remote Alarm Indicator or 4098-9789 Remote LED Alarm Indicator or 4098-9822 Unsupervised Relay 4" octagonal or 4° square box Unsupervised Relay Note: Box depth requirements depend on 4-Wire Sensor Supervised Relay 2098-9737 Supervised Remote Relay 40989791** Base with connections for LED total wire count and wire size, refer to 2098-9808 Remote Alarm Indicator or Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay accessories list below for reference. ** NOTE: 4098-9791 and 4098-9780 are NOT Sensor Supervised Relay 4098-9860 Supervised Remote Relay 40989780** Base with connections for LED compatible with the 2120 CDT 2098-9808 Remote Alarm Indicator or Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay TrueAlarm Sensors Model I Description 4098-9714 Photoelectric Smoke Sensor 4098-9733 Compatibility Bases 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Mounting Requirements Refer to base requirements TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting-Requirements 2098-9737 Supervised Relay, mounts remote or in base For use with 4098-9791 base Remote Mounting requires 4" octagonal electrical box or 4" square box, 1-1/2" minimum depth 4098-9860 Supervised Relay, mounts remote or in base Base Mounting requires 4" octagonal For use with 4098-9780 base electrical box - box, 2-1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator on single Bases 4098-9789, 4098-9791, Single gang box, 1-1/2" minimum depth gang stainless steel plate and 4098-9780 4098-9822 Unsupervised Relay, tracks base LED status; Bases 4098-9789, 4098-9791, 4" octagonal box, 2-1/8" deep with 1-1/2" Note: Mounts only in base electrical box and 4098-9780 extension ring Bases 4098-9792, 4098-9789, Required for surface or semi-flush =4098-9832Adapter Plate 4098-9791, and 4098-9780 mounted 4" square box and for surface mounted 4" octagonal box General Operatina Specifications Communications and Sensor Supervisory Power lDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32" to 100" F (0" to 38" C) Operating Temperature with 4098-9733 Heat Sensor Range with 4098-9714 Smoke Sensor 32" to 122" F (0° to 50° C) 15° to 122° F (-9° to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/mm (0-1220 m/min) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 pA, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power I Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TYCO, SiMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). ®S i In p1 EX Tyco Fire Protection Products" Westminster, MA 01441-0001 USA S4098-0019-20 1/2015 0 2015 Tyco Fire Projection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com _______ DESIGN: Models 4098-9780,-9780E, *.9772 -9789, -9789E, 9789T5P, -9789Tr1,9791E, -9791 TSP, 9791T1P,-9792, -9792E, -979215P, 9792TTP, -9793, -9793E, -9793TSP, -9793TTP, -9794, -9794TSP, -9794TTP, -9795,-9795TSP, -9795T1P, -9796, -9796T5P, -9796TTP; GSA4098-9780, -9792, -9793, -9795 and -9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Bases are intended for use with the following units: Models 4098-9714 and GSA4098-9714 series photoelectric smoke detector (CSFM Listing No. 7272-0026:218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:231); and Models 4098-9733, GSA4098-9733, *40989734 and *GSA4098..9734 heat detectors (CSFM Listing No. 7270-0026:216). Models 4098-9795, -9795TSP, -97951TP, -9796, -9796TSP, -97961TP; GSA4098-9795, and -9796 are only intended for use with Models 4098-9754 or G5A4098-9754 photoelectric smoke detector (CSFM Listing No.7272-0026:218). Refer to listee's printed data sheet for additional detailed product description and operational considerations. S INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Models 4098-9794, -9794T5P, -9794TTP, -9795, -9795TSP, -9795TTP, *.9772 and GSA4098-9795 employ a sounder, which is also suitable for use as a fire alarm audible signaling device. These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. *Rev. 04-21-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4098-9714, -9774, -9714T5P, -971411P, -9754 -9754T5P, -97541TP; Id -1011 11 , -9754 analog photoelectric type smoke detectors. Units are intended for use with smoke detector bases Models 4098-9789 978915P, -97891TP, -9791, -9791T5P, * 9775 * -9776, *..9777 -979111P, -9792, -9792T5P, 9792TTP, -9793, 9793T5P, -9793T1P, -9794, -9794T5P,-9794TTP; G5A4098-9792, and -9793 (CSFM Listing No. 7300-0026:217). Models 4098-9714, -9714TSP and -9714TTP are listed for use with Models 4098-9750-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:220) and Models 4098-9755, -9755T5P and -9755TTP duct detector units (CSFM Listing No. 3240-0026:241). Models 4098-9754, *9779 -9754TSP, -97541TP; GSA4098-9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. Revision 12-13-2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: 40 01, 2017 July Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S £LSimpIEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control S I 1!I4.1 Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNet or MAPNET II, 2-wire communications Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNet!MAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interlace board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simples Time Recorder Co. are the property of Tyco Fire Protection Products. ...... . .... ........ ........ ............... Duct Sensor Housing, Front and Bottom View m 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station rirItHfie Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. IIl!t7.MI III- I1m11.] &SI .IWuff01i1 Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. S4098-0030-9 11/2012 bi7TT.bi iiv1] Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) irii1 Ffli9 TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. ir 1fl!fT1Mrij Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. I Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor information in plain English language Relays of model 4098-9756 are under panel control S ior ON, OFF, or overriue Duct Smoke Sensor Housing with Photoelectric Sensor* \ \\ IP1T 1I.]& TTIl flI Model Description Compatibility Basic Duct Sensor Housing; operating power is supplied by Simplex fire alarm control panel models: 4100ES, 401 OES, 4008, 4010, 4100U, and legacy products 4098-9755 either IDNet or MAPNET II communications (no relay 4020, 4100/4100+, and 4120. Also 2120 CDT if output) configured for MAPNET II, TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not compatible with 2120 CDT; 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 Relay output is for up to 15 total 4098-9843 Relays end-of-line resistor harness; includes one 4098-9843 relay (additional relays are ordered separately) Model Description Compatibility Mounting \\ Remote LED Indicator and Test Station, Select One if Required 2098-9808 Red LED status indicator on single-gang stainless steel plate Use single gang box, Test Station with keyswitch and red LED status indicator, on 4098-9755 3" H x 2" W x 2" D 2098-9806 single-gang stainless steel plate; (turning switch to "TEST" 4098-9756 (76 mm x 51 mm x 51 mm) initiates alarm for system testing) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 4098-9756 only; Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; connect up to 15 (1 m) of device being wiring is 18 AWG (0.82 mm2) color coded wire leads controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 k), 1/2 W; (ref. 733-894); 4098-9756 At last relay location required to supervise remote relay coil connection * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Overall Duct Width (305 mm) Tube Required 4098-9854 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 4098-9855 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 4098-9856 3 in" (76 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 4098-9857 3 in" (76 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 4098-9858 3 in" (76 mm) longer than duct width S4098-0030-9 11/2012 S S screws : rrn nyi 'I1I4(]I{.I NOTE: Refer to Installation Instructions 574-776 for additional installation detail and maintenance information. 11-3/8(289 mm) [Exhaust tube access hole 1 4098-9714 Smoke sensor, mounted in special interface base (supplied) 6-3/4 (171 1mm) 1 acce 5s hole _L baffle Metal with dual holes -" for 3/4 (19 mm) conduit plug Ii Z i supplied for unused hole DODD 71t n n crn On 'j'ellow LED, relay control trouble 2 jindicator (4098-9756 only) Fled sensor I lUll itatus LED Side of duct 09 NOTE: Orientation shown is for reference sensor areaJ only, refer to General Location Notes and End View illustration below for alternate mounting reference. 3-3/8" (86 mm) (21 mm) I Test ports (2) provided for measuring airflow and for aerosol injection Exhaust tube I (supplied) Sampling tube, ordered separately per duct width 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 1- 7~~V 13/16" (38 mm)(21 mm) - Square duct reference outline Alternate location (j[ appropriate) 18" Round duct outline (minimum diameter) Sampling ube, keyed for proper hole alignment with holes facing into airflow (template is provided for proper tube ins Duct housing tallation). (Housing is shown as position 2 per note 2 below.) General Location Notes: Testing performed under the auspices of the Fire Detection Institute (FDI) recommended when sampling tubes are not located vertically, that they be positioned horizontally in the upper half of the duct to account for possible stratification. Three duct side mounting options are available as shown below. Mount housing at 90 to airflow for all orientations. Arrows indicate allowed airflow directions. S I \ I .tExhaust tube duct outlinel DO NOT MOUNT ON BOTTOM OF DUCT /\ 3 S4098-0030-9 11/2012 Duct Sensor Location Reference Exhaust Damper Se Exhaust 7R etum Do not locate sensor here air amper /// L., Fresh air-.- Ii Ii / Do not locate Filter bank sensor here Additional Information. Refer to NFPA 90A, Standard for the Installation ofAir Conditioning and Ventilating Systems; NFPA 72, the National Fire Alarm and Signaling Code; and the NEMA Guide for Proper Use of Smoke Detectors in Duct Applications, and Installation Instructions 574-776. Duct Sensor Location Considerations: Proper duct smoke detection location must ensure adequate airflow within the duct housing. Duct air velocity rating is 300 to 4000 ft/min (91 to 1220 mlmin). Pressure differential between intake and exhaust tubes is required to be between 0.015 to 1.55 inches of water (0.381 to 39.37 mm). Ensure accessibility for test and service. Proper Locations: downstream side of filters to detect fires in the filters; in return ducts, ahead of mixing areas; upstream of air humidifier and cooling coil. Other locations and orientations may be required for proper duct smoke detection depending on duct access, system design, and duct airflow testing. Contact your local Simplex product supplier for assistance. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. OK -Return Air —b- Supply Air Sensor OK S S Specifications General Mechanical and Environmental Air Velocity Range (linear ft/min) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Black base with clear cover Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 ml maximum Addressable Operation Data Communications IDNet or MAPNET II communications, auto-select, one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current 3 mA @ 24 VDC Alarm Current 15 mA @ 24 VDC; add 15 mA for each 4098-9843 relay Supervised Remote Relay Control Output For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 kc, 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output Relay Contacts 7 A at 0.35 PF © 28 VDC & 120 VAC; 250 pA @ 5 VDC Location Distance 500 ft (152 m) maximum to relay coils; locate relays within 3 ft (1 m) of device beina controlled oer NFPA 72 TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling code are registered trademarks of/he National Fire Protection Association (NFPA). 0 5®S irn p1 EX Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4098-0030-911/2012 www.simplexgrinnell.com 02012 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 3240-0026:0241 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexlo0 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4098-9755, *4098..9755Tsp *40989755up 4098-9756, 4098-9756T5P, *40989756up 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/min INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to Iistee's Installation Instruction Manual for details. NOTE: *Rev. 11-06-03 r, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee s data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexlOo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. NOTE: S *Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 4090-9051 Supervised lAM (shown approximately 3/4 size) U.Simpkx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* ITh'It4-1 IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from JAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use in indoor locations up to 158° F (70° C) such as attic spaces or similar applications For use with following Simplex control panels: Model Series 4007E5, 4008, 4010, 4010ES, and 4100E5 fire alarm control panels for IDNet communications Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simples product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet and MAPNET II Communicating Devices, Individual Addressable Modules (lAMs) 1sh ii: SlPllf llf[ BCOfD[f CO. 4090-fool SUPMISID 1ff 9t1. 1611. fIt-OIl EM 4090-9001 Supervised lAM (shown approximately 3/4 size) flrsrintinn Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET H or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. S4090-0001-11 11/2014 D n ratk Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). IRM For use with IDNet communications only, these JAMs can provide quad-state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterflow switch monitoring can be determined and communicated by a single addressable point. lTI J71 r!rIfl ritrm Model Description 4090-9001 Supervised lAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 1 Supervised lAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 1 For semi-flush mounted box 4090-9807 1 For surface mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, includes mounting screws; galvanized steel 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No Description 4081-9004 733-886 6.8 k1, 1/2 W; Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 1 733-896 1 4.7 kc, 1/2 W 4081-9005 I 733-984 11.8 kc, 1/2W Use for current limited monitoring applications S Specifications Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per lAM Input Requirements Normally open, dry contacts Wire Connections 4090-900 1 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wiring Diagrams 574-331 for 4090-9001; 579-572 for 4090-9151 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from lAM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or I 2500 ft (762 m) maximum from fire alarm control panel IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical 4090-9001 Dimensions 4090-9051 1-9/16"Wx1-3/4"H xl-1/4"D(40mmx44mmx32mm) 1-9/16"W x 1-9/16" H x 9/16"D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32' to 158° F (0° to 70" C); intended for indoor operation Humidity Range Up to 93% RH at 100° F (38" C) 2 S4090-0001-11 11/2014 ®R-er."', LED viewing port Mounting Information 4090-9001 lDNet Field wiring shown supervised lAM for reference S Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 4-1/4" (108 mm) Light pipe for © LED viewing (114 mm) :}'(4:Eij POSER DISCONNECT POWER EEFORE SERVICING REFORE SEFSC!NG © © CD 2-1/2" __ (64 mm) 4090-9806, Trim plate for semi-flush mounted box 2-13/16" (72 mm) No 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 2 S4090-0001-11 11/2014 4090-9051 Mounting Information Address setting is at rear of housing 4090-9051 Sjupervised IAM Encapsulated Single gang electrical box 2-1/2 (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) C S Jj'SiMpJ,EX Tyco Fire Protection Products• Westminster, MA • 01441-0001 USA S4090-0001-11 11/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. Al! rights reserved All specifications and other information shown were current avofdocument revision date and are subject to change without notice. S ire lit MW 1 4090-90020 4090-9002 IDNet Relay lAM Package (shown approximately 1/2 size) Specifications Communications IDNet communications, 1 address per device Relay lAM Power Supplied by IDNet communications Contact Ratings* (not rated for incandescent switching) Type Form C, SPDT 2 A @ 24 VDC, resistive from listed Power-Limited fire alarm 1 A @ 24 VDC, inductive supply Nonpower-Limited 0.5 A @ 120 VAC, resistive * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120 VAC loads may require RC networks or varistors, depending on device type. Refer to the installation instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (082 to 208 mm) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4 1/" H x 4 1/8 W x 1 %" D (105 mm x 105 mm x 35 mm) Housing Material Black thermoplastic Mounting Plate Sheet metal, galvanized Temperature 32* to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) Installation 574-184 Instructions £LSim plEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Multi-Application Peripherals IDNet Communicating Devices Model 4090-9002 Relay lAM S S N I11II*I Individual Addressable Relay Module (Relay lAM): IDNet addressable control for use with Simplex® fire alarm control panel models 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U A single addressable point provides control and status tracking of a Form "C" contact Low power latching relay design allows IDNet communications to supply both data and module power Relay is set to OFF on initial power up and upon loss of IDNet communications Compact, sealed construction: . Enclosed design minimizes dust infiltration Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 11/ (119 mm) square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 I DIT-181 iF1It1Th IDNet Relay lAMs allow fire alarm control panels to control a remotely located Form "C" contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Product Selection Model Description 4090-9002 Relay lAM Optional Adapter and Trim Plates Model Description 4090-9813 Adapter plate to fit 4 /16 (119 mm) square electrical box 4090-9801 For semi-flush I Trim Plate, galvanized mounted box I steel, with LED viewing I window; includes For surface 4090-9802 mounted box mounting screws S * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300.0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings— MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4090-0002-10 11/2014 Relay lAM Mounting Information Address setting under resealable label -" C IS Li r;J 5\ 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO - 232 or equal (supplied by others) 4090-9002 Relay lAM Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © © © Light pipe for LED viewing 4-9/16" 4-5/16" (116 mm) cf" /' [SCECTP3S] (109 mm) © © © © (116 mm) IiI 11 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4090-0002-10 11/2014 www.simplex-fire.com 02014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as of document revision dale and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models" 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9106TSP, and-9106T1P Class "A" ZAM Initiating Module; 4090-9101, -9101TSP, and -9101TTP Class "B" LAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: S "Recert. 03-29-2006 jw TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S S's implEx TrueAlert 0 Addressable Notification Appliances UL, ULC, CSFM Listed; Visible Notification Appliances, Wall Mount FM Approved* 9 Multi-Candela Strobes, Model Series 49V0 S 17-M 7M Individually addressed and controlled multi-candela TrueAlert ES VIO (visible only) notification appliances provide: Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmablefrom the control panel orjumper selected as 15, 30, 75, 110, 135, or 185 cd Advanced addressable notification controlled by IDNAC SLCs from Simplex® 4100ES fire alarm control panels with EPS/EPS+ power supplies (and 4009 IDNAC Repeaters) providing regulated 29 VRMS allowing strobes to operate with lower current even under battery backup Wiring supervision to each appliance allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 3) Magnet lest diagnostics to assist checkout and testing of appliances and wiring and Electrical test point access without removing cover Compatibility with ADA requirements; (refer to important installation information on page 3) Compatibility with legacy TrueAlert addressable systems for upgrade and replacement (see page 4) Listed to UL Standard 1971 and ULC Standard S526 LED Indicator and magnet test feature: Appliance LED can be selected to display each polling cycle to indicate appliance supervision When the controller is in diagnostic mode, the magnet test pulses the LED to indicate appliance address and can be set to also briefly flash the strobe Mechanical design features include: Rugged, high impact, flame retardant thermoplastic housing in red with white letters or white with red letters, with clear lens, available with FIRE, ALERT, FEU, FIRE/FEU, or blank lettering Separate covers are available to change appliance type on-site or for replacement; covers can be easily removed without disturbing the connected housing and avoiding trouble conditions A separate mounting plate allows wiring to be completed before appliance is mounted; use with single gang, double gang, or 4-inch square box, flush or surface mount In/out wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7135-0026:0373 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. TrueAlert ES Addressable Strobes are Available in Red with White Lettering and White with Red Lettering ri ml An TrueAlert ES addressable strobes are individually addressed visible notification appliances that receive power, supervision, and control signals from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 4) Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117. 1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). 1111 rM nil *ii. oIirivY erq TrueAlert ES addressable appliances on IDNAC SLCs provide separate visible (and audible) notification using a single two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VRMS source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. S49V0-0001-1 5/2013 Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. • Test Features. Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. wrri Silent Appliance Magnet Test. In this test mode, in response to the magnet test, the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Testing. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSlT). The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test lDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (Refer to data sheet S4905-0001 for additional information.) S Product Selection TrueAlert ES Wall Mount Addressable Strobes TrueAlert ES addressable VO (strobe) appliances include cover and matching mounting plate except as noted; Dimensions with Cover = 51/8" H x 5"Wx 1 1/2 D(130 mm x 127 mm x 38 mm) Model Cover Color Wording Lens Color Model Cover Color Wording Lens Color 49V0-WRF(-BA) Red FIRE 49V0-WRS-BA Red 49VO-WNF(-BA) White ______________ __________ Clear Blank Clear 49V0-WRA-BA Red 49V0-WWA-BA White ALERT 49V0-WWS-BA White 49V0-APPLW Select cover and mounting plate separately Separate Mounting Plate Model WR I Color Note 49MP-AVVO Red Mounting Plate is required when ordering model 49V0-APPLW Separate Covers (Required when ordering model 49V0-APPLW) Model 49V0C-WRFIRE Color Red Wording FIRE Model 49V0C-WRFEU Color Red Wording FEU 49VOC-MJVFlRE White 49V0C-WNFEU White 49V0C-WRALT Red ALERT 49V0C-WRBLNG Red FIRE/FEU White 49V0C-\MNALT White 49V0C-WWBLNG 49V0C-WRS Red Blank 49V0C-WWS White Blank * Note: (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA, APPLW models, and separate mounting plates are assembled in the USA. Mounting Adapters Model Color Description 4905-9937 Red 4905-9940 White Surface Mount Adapter Skirt 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 Box I (typically for retrofit, mount vertical or horizontal) 2975-9145 1 Red Mounting Box, requires 4905-9931 Adapter Plate Dimensions 5%"Hx5WWx1 %"D(136mmx133mmx41 mm) Total depth with strobe = 4 /" (111 mm) 8 /16 x 5%" x 0.060" Thick (211 mm x 146 mm x 1.5 mm) 7 7/a"x 5 %"x2%" D(200 mm x130 mmx70 mm S49V0-0001-1 512013 " TrueAlert ES - Addressable Strobe S 3 4905-9931 Adapter Plate TrueAlert Device Reports Reference Service REPORT 5 Port : TrueAlert Device Report Page 1 12:34:56am MON 20-May-13 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA T14-1-1 Location Label up to 40 characters V/O 15 T14-1-2 Break Room 5 A/V 110 T14-1-3 Boiler Room A/V 75 T14-1-4 Elec. Room 7 A/V 135 irfl lrTTTh S gqv Wiring access LED indicator hole Address setting DIP location °1*.unting Mounting plate switch, accessible from rear of housing Holes. Single gang (2) netic test location -. ottom of housin 110 Th 4" square (4) ,( 75 0 Strobe intensity 30 -Intensity selection plug, accessible viewing slot on from rear Of satph appliance !C ] setting is FACP Electrical test point access holes (on bottom) (not to scale) 185 controlled by panel IMPORTANT! WALL MOUNT INS ILLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly above L bottom of compatible Electrical boxes box outline 80" (2.03 m NFPA 72 minimum requires that the entire lens be not less than 80" and not greater than 96" above the finished floor (confirm with your local codes) Mounting is compatible with single gang, double gang, and 4(102mm) square boxes, 1-1/2" (38 mm) deep, supplied separately Wring terminals and Transparent connection dips housing assembly Removable cover (use bladed screwdriver to release latch : left side) Adapter Plate and Surface Mount Installation Reference r —,b'!.1:Ii'TT1r,i,r.-- 4905-9931 Adapter Plate Surface Mount Side View Reference (Surface mount conduit and box shown for reference) TrueAlert ES Addressable Strobe 4" square box 1-1/2" (38 mm) deep Optional surface mount adapter skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, 'Mite (conduit knockouts are provided on all four sides) S49V0-0001-1 5/2013 TrueAlert ES Appliance and IDNAC SLC Controller Compatibility Reference Compatible Controller and additional TrueAlert ES Appliances Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 29 VRMS (regulated) S49WP-0002 23 VRMS (with 6 VRMS drop) 4009 IDNAC Repeater S4009-0004 TrueAlert ES Audible Only (Horns) 549A0-0001 TrueAlert ES Audible/Visible S49AV-0001 TrueAlert ES Weatherproof UL Listed Appliances ULC Listed S49WP-0001 TrueAlert ES Strobe Specifications Electrical Ratings Typical Operating Voltage Range 23 VRMS to 31 VRMS, Special Application (see below for 17 VRMS rating) Supervisory Requirements 1 unit load SLC Loading Maximum of 63 addresses per SLC, 75 unit loads Candela Setting 15 c I 30 c I 75 c I 110 c I 135 c I 185 c 23 VRMS Current Ratings, for typical design of 47 mA IDNAC Addressable SLCs (6 VRMS drop) 57 mA 100 mA 132 mA 160 mA 208 mA General Specifications Temperature Range 320 to 122° F (00 to 50° C) Humidity Range 10% to 93%, non-condensing @ 104° F (40° C) IDNAC SLC Wiring Specifications (refer to control panel installation instructions for more information) UTP, unshielded twisted pair recommended Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 10,000 ft (3048 m) Maximum wire length to any appliance = 4000 ft (1219 m) Maximum wiring resistance between compatible appliances = 26 C) Connections Terminal blocks on mounting plate for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ); two wires per terminal for in/out wiring Installation Instructions 579-1031 Notes: Refer to compatibility table above for fire alarm control panel and power supply operation type. TrueAlert ES Strobe LEGACY Compatibility Reference Compatible Controller Data Sheet Controller Output Available Strobe Appliance Voltage Reference Intensity Minimum 4100ES or4100U with S4100-0031 TrueAlert Power Supply TrueAlert 15, 30, 75, and 110 cd 17 VRMS 4009 TPS, Remote S4100-0037 TrueAlert Power Supply Addressable SLC TrueAlert Addressable S4009-0003 Controller (40091) Electrical Ratings Reference for Retrofit Applications Voltage Range 17 VRMS to 31 VRMS, Special Application Candela Setting 15 c 30 c 75 c 110 c 17 VRMS Current Ratings, use when connected to TrueAlert Addressable SLCs per 62 mA 75 mA 133 mA 178 mA above TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association (NFPA). !3®S i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S49V0-0001-1 5/2013 0 2013 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. -, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0373 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Model 49AVTrue Alert ES addressable horn/strobes with suffixes WRF, WRF-BA, WNF, W.NF-BA, *WRs WRS-BA, WWS-BA, *WRQ WRQ-BA and APPLW. Model 49AVTrue Alert ES addressable horn/strobe covers with suffixes WRFIRE,WrNFIRE, WRS,VVWS, WRALT, \MNALT, WRFEU, \WVFEU, WRBLNG, and \MNBLNG. Model 49VOTrue Alert ES addressable strobes with suffixes WRF, WRF-BA, WrNF, VWVF-BA, *wRS WRS-BA, *5 \MNS-BA, *A WRA-BA, *A WWA-BA, *\Q *Q ,WRQ-BA, and *Q Model 49VOCTrue Alert ES addressable strobe covers with suffixes WRFIRE, WWFIRE, WRS, WINS, WRALT, WWALT, WRFEU, WWFEU, WRBLNG, and WNBLNG. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 17-31 Vdc S INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a wall mount horn/strobe or strobe for indoor use only. Models require the use of the 4009-9401 TrueAlert NAC extender (CSFM Listing No. 7300-0026:214) or 4100-5120, -5121, -5122 True Alert Power Supples*or 4100-5311, -5313, -5325, 53-27 Extended Power Supplies (CSFM Listing No. 7165-0026:251) *0r40109601 -9602, -9603, -9604, -9606, 9701, -9702, 9722 Control Units (CSFM No. 7165-0026:369) or 4007-9201, -9202 Control Units (CSFM No. 7165-0026:378). Refer to listee's Installation Instruction Manual for details. *Rev 09-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S !LSimplEx TrueAlert Addressable Notification Appliances UL, ULC Listed* 71 Wall and Ceiling Mount Addressable Speaker iF and Speaker Visible Notification Appliances n Il1uI(*I Individually addressed and controlled Speaker (SIO) and Speaker Visible (SN) notification appliances Advanced addressable notification controlled by IDNAC SLCs provides regulated 29 VDC for low current operation even under battery backup. Wiring supervision is electronically monitored and allows audio wiring to be T-tapped for class B wiring, reducing wiring costs and wiring distances. Speaker selectivity is controlled by the panel. Only those speakers that are needed are connected to the audio NAC. Separate appliance and cover selection greatly simplifies the ordering and installation process. Strobe intensity can be programmed from the control panel or the device for S/V models. Self-Test Mode allows on-board sensors to detect the strobe and speaker output and then report their status to the control panel. Wiring terminals separate from the Audio terminals. TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting. Magnet test diagnostics to assist checkout and testing of appliances and wiring. Compatibility with ADA requirements. LED indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address and pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount models Covers are available in- red or white with various lettering options Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts to 4" square 2 ¼" gang US electrical boxes * Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Ceiling and Wall Mount Addressable Speaker Only and Speaker Visible Strobes 13*11112TTRITZI MR Speaker design features High quality voice and tone reproduction with taps for Y4, ¼, 1, or2W, at 25 or 70.7 VRMS Speakers have capacitor input for connection to DC supervised NACs and are wired separately from strobes Listed to UL 1480 and ULC S541 * Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas High and low frequency response models available, 200-10000 Hz and 400-4000 Hz respectively. Imi*il1ITT1 Wall and ceiling mount addressable speaker and speaker visible appliances provide convenient installation to standard electrical boxes. The speaker is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel IDNAC Signaling Line Circuit (SLC). Audio is provided by a panel that supports audio output or from a separate audio source. Appliances use a multi-tapped speaker for audio/tone notification. il71 lIT 1111 Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S49SWC-0001-1 11/2015 ____________________ TrueAlert Addressable speaker and speaker Isolator Model 4905-9929 is available for remote visible appliances on IDNAC SLCs provide visible mounting on TrueAlert addressable circuits to isolate short and audio notification using two separate two-wire circuited wiring from functioning wiring. Refer to data sheet circuits that also confirms connection to the individual S4905-0001 for additional information. notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring Test Features connections. Controllers can be selected to pulse each appliance's LED Reduced current usage on IDNAC SLCs when it receives a supervision poll. When the controller is A constant 29 VDC source voltage is maintained, even selected for diagnostic mode, the appliance magnet test during battery standby. This allows appliances to operate feature provides a response at the individual appliance being at higher voltage with lower current and ensuring a tested. consistent current draw and voltage drop margin under Silent Appliance Magnet Test both primary power and secondary battery standby. The appliance LED pulses sequentially to conveniently Efficiencies include wiring distances up to 2 to 3 times indicate the appliance's address when a magnet is applied. farther than with conventional notification, support for Operational Appliance Testing more appliances per IDNAC SLC, use of smaller gauge In this test mode, after the address is indicated by pulsing the wiring, or combinations of these benefits. appliance LED, the strobe will briefly flash to indicate Reducing Installation and Testing Time proper operation. With separate controls on the same two-wire SLC, TrueStart Instrument Two (TSIT) installation time and expense for both retrofit and new The 2nd generation of the Simplex TrueStart Test construction can be significantly reduced. When Class B Instrument adds testing of IDNAC SLC wiring and wiring is used, wiring can be "r' tapped, allowing more TrueAlert (and TrueAlert ES) appliances to its ability to test savings in distance, wire, conduit (size and utilization), and IDCs, NACs, and IDNet communications before connection overall installation efficiency. Use of the magnet test feature to the control panel. Please contact your local Simplex improves installation efficiency. TrueAlert device reports representative for additional information. conveniently identify information about each connected appliance. _ . I'i'fl I It mI.TThiits.i rri Wall Mount SIO Appliances* (Refer to data sheet S49SOW-0001 for full product selection including covers and mounting plates) Model I Dimensions I Description I Data Sheet Reference 49SO-APPLW(-BA 51/2' H x 5" W 1 1/2' D Isio appliance only 49HF-APPLW(-BA) 1(139 mm x 128 mm 38 mm) I High fidelity Sf0 appliance only \ Wall Mount SN Appliances* (Refer to data sheet S49SVW-0001 for full product selection including covers, mounting plates, and multi-color strobe lens) Model Series Dimensions Description Data Sheet Reference 49SV-APPLW(-BA) 17 W H x 5" W x 1 D SN appliance only S49SVW - 0001 49HFV-APPLW(-BA) (187 mm x 128 mm x 43 mm) High fidelity SN appliance only *Note: Wall mount models require separately ordered back plate. See related datasheet for details. Ceiling Mount Appliance Product Selection Ceiling Mount S/O Appliances (Refer to data sheet S49SOC-0001 for full product selection and installation requirements) Model Dimensions Description Data Sheet Reference 49SOAPPLC(BA) 7 WH x 7 1/a W x 1 1/4 D Sf0 appliance only s49s0c-0001 49HF-APPLC(-BA) (180mm x 180 min x 32 mm) High fidelity SIO appliance only '\ Ceiling Mount SN Appliances (Refer to data sheet S49SVC-0001 for full product selection and installation requirements) Model Series Dimensions Description Data Sheet Reference 49SV-APPLC(-BA SN aooliance only 49HFV-APPLC(-BA) High fidelity SN appliance only 49SVH-APPLC(-BA) High candela SN appliance only 8W'Hx7WWx3"D Clear lens high fidelity high candela 49HFvH-APPLC(-BA) (206 mm x 180 mm x 76 mm) SN appliance only S49SVC-0001 Amber lens high fidelity high 49HFVH-APLCA-BA candela SN appliance only Blue lens high fidelity high candela 49HFVH-APLCB-BA SN aooliance only Note: Select appliance, cover and mounting back plate (where required) separately. (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are assembled in the USA S49SWC-0001-1 11/2015 S S IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4100ES Flex 35, 50, and 100 Amplifiers S4100-0034 4100ES Constant Supervision and Signal Cards Specifications General Specifications (refer to individual model data sheets for further specifications, install and operation details) Typical Operating Voltage Range 23 - 30 VDC, Special Application Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Terminal blocks for 18 AWGto 12 AWG (0.82 mm to 3.31 mm'); two wires per terminal Connections for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible fire panel installation instructions for circuit current load limits. Speaker Specifications Input Voltage 25 or 70.7 Vrms PowerTaps Y,%,1, and 2W 400 to 4000 Hz and 200 to 10000 Hz, Frequency Response General Signaling = 125 to 12 kHz respectively. Strobe Specifications Typical Operating Voltage Range 23 - 30 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate 1 Hz IDNAC SLC Wiring Specifications (refer to control panel installation instructions for more information) UTP, unshielded twisted pair recommended Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 10,000 ft (3048 m) Maximum wire length to any appliance = 4000 ft (1219 m). This can be doubled to 8000ft (2438m) by using a 4009 IDNAC Repeater. Note: Speakers are for connection to compatible fire alarm audio circuits only. S49 Series Speaker Datasheet Reference Model Data Sheet Reference Wall Mount Speaker Only Appliance S49SOW-0001 Wall Mount Speaker Visible Appliance S49SVW-0001 Ceiling Mount Speaker Only Appliance S49SOC-0001 Ceiling Mount Speaker Visible Appliance S49SVC-0001 S49SWC-0001-1 11/2015 n S S S TYCO, SiMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®S I in p1 EX Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S49SWC-0001-1 11/2015 www.simplex-fire.com 0 2015 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current an ofdocument revision date and are subject to change without notice. ( CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7320-0026:0322 Page 1 of 1 CATEGORY: 7320 -- SPEAKERS LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models 4906-9251 and -9253 TrueAlert addressable wall mount speaker strobes. Models 4906-9254, *4906..9255 and 4906-9256 TrueAlert addressable ceiling mount speaker strobes. Suitable for indoor use only. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 25 or 70.7 V rms, 1/4, 1/2, 1 and 2 Wattage Taps Candela: All models listed have selectable candela ratings of: 15cd, 30cd, 75cd, or 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number electrical/candela rating and UL label. APPROVAL: Listed as hearing impaired speaker strobes for use with separately listed fire alarm control units. Refer to manufacturer's Installation Manual for details. S These devices do not generate a temporal pattern code. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Rev 07-23-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 SimplexGrinnell Fax: (858) 633-9101 www.simplexgrinnell.com License Number 986047 SIMPLEXGRINNELL LP 12728 SHOEMAKER AVENUE SANTA FE SPRINGS, CA 90670 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/3112017 License Status This license is current and active. All information below should be reviewed. [eHIariflT ,.T TI C10 - ELECTRICAL C16 - FIRE PROTECTION CONTRACTOR SWIMPOW Contractor's Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 10/01/2016 Bond of Qualifying Individual This license filed Bond of Qualifying Individual number 82332031 for MAYLE RONALD GILBERT in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for ROSTEN TIMOTHY PAUL in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 - .iWorkers Compensatiorit... This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC308342 Effective Date: 10/01/2016 Expire Date: 10/01/2017 Workers' Compensation History S 10/4/2016 REV.#: 0 PROJECT #: 480-XXXXXX-XX / XX)00000(X tqcn SimplexGrinnell SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to-the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected WARRANTY SERVICE HOURS- - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST 10/4/2016 REV.#: 0 PROJECT #: 480-XXXXXX-XX / XXXX)OO(XX S S