Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 208; FPC2017-0197; Permit4ity of Carlsbad Au(~~ Print Date: 10/24/2022 Permit No: FPC2017-0197 Job Address: 2525 EL CAMINO REAL, #208, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 1563020900 Track #: Applied: 07/19/2017 Valuation: $888,943.90 Lot #: Issued: 07/27/2017 Occupancy Group: Project #: Finaled Close Out: 02/07/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Wong, Cindy Plan Check #: Project Title: Description: YARD HOUSE -SPRINKLER TI >100 HEADS (102) SHELL PORTION Applicant: FPContractor: VFS FIRE AND SECURITY SERVICES BERN EL INC SALVADOR JASSO 501W SOUTHERN AVE 501 W SOUTHERN AVE ORANGE, CA 92865-3217 ORANGE, CA 92865-3217 (714) 778-6070 (714) 919-8351 FEE AMOUNT FIRE NFPA 13 or 13R System > 100 heads $634.00 Total Fees: $634.00 Total Payments To Date: $634.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FPC20I7-0197 2525 EL CAMINO REAL UNIT208 FILE Copy FIRE & SECURITY SERVICES VFS Fire & Security 501 W Southern Ave Orange CA., 92865 714-778-6070 Job Name : THE SHOPPELS AT CARLSBAD Building : FP-3.1 Location : 2525 EL CAMINO REAL CARLSBAD, CA System : SYS-1 1 AREA 1 Contract : 163173 Data File : SYS-1 1 YARD HOUSE .WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C VFS Fire & Security Page 1 THE SHOPPELS AT CARLSBAD Date 05-10-2017 City Water Supply: Demand: Cl - Static Pressure : 82.8 Dl - Elevation : 13.210 C2 - Residual Pressure: 37.8 D2 - System Flow : 364.347 C2 - Residual Flow : 6050 D2 - System Pressure : 73.500 Hose ( Demand) : 250 D3 - System Demand : 614.347 Safety Margin : 8.646 150 140 130 p120 R° E10° S 90 C1 DZ- s 80 U7° R 60 E 50 -- 40 : 20 -9-1— 10 - I — ...l I I I _____________________________ 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (NA1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - NFPA 2007 /FS Fire & Security Page 2 THE SHOPPELS AT CARLSBAD Date 05-10-2017 SUPPLY ANAL YSIS Node at Source Static Pressure Residual Pressure Flow Available Pressure Total Demand Required Pressure CON 82.8 37.8 6050.0 82.146 614.35 73.5 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes HD1 26.5 5.6 21.56 26.0 1 26.5 5.27 24.3 26.0 K=K @ HD2 2 26.5 5.27 24.97 26.35 K=K @ HD2 3 26:5 5.27 25.86 26.82 K=K @ HD2 4 26.5 5.27 27.77 27.79 K=K @ HD2 5 26.5 5.27 31.11 29.42 K=K@ HD2 6B 26.5 42.09 7 26.5 5.27 24.33 26.01 K=K @ HD2 8 26.5 5.27 24.99 26.37 K=K @ HD2 9 26.5 5.27 25.89 26.83 K=K @ HD2 10 26.5 5.27 27.8 27.81 K=K@ HD2 11 26.5 5.27 31.14 29.43 K=K @HD2 12B 26.5 42.13 13 26.5 5.27 32.5 30.06 K=K@ HD2 14 26.5 5.27 33.36 30.46 K=K @ HD2 15 26.5 5.27 34.53 30.99 K=K @ HD2 16B 26.5 44.81 6 26.5 46.82 12 26.5 46.86 16 26.5 47.07 17 26.5 51.05 TRS 26.5 54.41 BRS2 2.0 65.17 UG -4.0 67.8 UGI -4.0 68.2 UG2 -4.0 68.2 DC1 -4.0 68.24 DC2 -4.0 73.34 250.0 CON -4.0 73.5 Computer Programs by Hydratec Inc. Revision: 50.52.1 FS Fire & Security Page 3 THE SHOPPELS AT CARLSBAD Date 05-10-2017 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf HD1 26.500 5.60 26.00 1 E 2.0 6.000 120 21.556 to T 5.0 7.000 0.0 HD2 26.500 26.0 1.049 0.0 13.000 0.2115 2.749 Vel 9.65 0.0 HD2 26.00 24.305 K Factor = 5.27 1 26.500 5.27 26.00 1.5 4E 19.799 11.500 120 24.305 K = K@ HD2 to 0.0 19.799 0.0 2 26.500 26.0 1.682 0.0 31.299 0.0212 0.664 Vel = 3.75 2 26.500 5.27 26.35 1.5 0.0 11.500 120 24.969 K= K@HD2 to 0.0 0.0 0.0 3 26.500 52.35 1.682 0.0 11.500 0.0774 0.890 Vel = 7.56 3 26.500 5.27 26.82 1.5 0.0 11.500 120 25.859 K= K@ HD2 to 0.0 0.0 0.0 4 26.500 79.17 1.682 0.0 11.500 0.1664 1.914 Vel = 11.43 4 26.500 5.27 27.79 1.5 0.0 11.500 120 27.773 K= K@ HD2 to 0.0 0.0 0.0 5 26.500 106.96 1.682 0.0 11.500 0.2903 3.339 Vel = 15.44 5 26.500 5.27 29.42 1.5 T 9.9 14.208 120 31.112 K= K@ HD2 to 0.0 9.900 0.0 6B 26.500 136.38 1.682 0.0 24.108 0.4552 10.974 Vel = 19.69 6B 26.500 0.0 1.5 T 9.9 0.500 120 42.086 to . 0.0 9.900 0.0 6 26.500 136.38 1.682 0.0 10.400 0.4552 4.734 Vel = 19.69 0.0 6 136.38 46.820 K Factor = 19.93 7 26.500 5.27 26.01 1.5 4E 19.799 11.500 120 24.329 K= K@ HD2 to 0.0 19.799 0.0 8 26.500 26.01 1.682 0.0 31.299 0.0212 0.665 Vel = 3.76 8 26.500 5.27 26.37 1.5 0.0 11.500 120 24.994 K= K@ HD2 to 0.0 0.0 0.0 9 26.500 52.38 1.682 0.0 11.500 0.0775 0.891 Vel = 7.56 9 26.500 5.27 26.83 1.5 0.0 11.500 120 25.885 K= K@ HD2 to 0.0 0.0 0.0 10 26.500 79.21 1.682 0.0 11.500 0.1666 1.916 Vel = 11.44 10 26.500 5.27 27.81 1.5 0.0 11.500 120 27.801 K= K@ HD2 to 0.0 0.0 0.0 11 26.500 107.02 1.682 0.0 11.500 0.2906 3.342 Vel = 15.45 11 26.500 5.27 29.43 1.5 T 9.9 14.208 120 31.143 K= K@ HD2 to 0.0 9.900 0.0 12B 26.500 136.45 1.682 0.0 24.108 0.4556 10.984 Vel = 19.70 12B 26.500 0.0 1.5 T 9.9 0.500 120 42.127 to 0.0 9.900 0.0 12 26.500 136.45 1.682 0.0 10.400 0.4556 4.738 Vel = 19.70 0.0 12 136.45 46.865 K Factor= 19.93 13 26.500 5.27 30.06 1.5 4E 19.799 11.500 120 32.496 K= K@ HD2. to 0.0 19.799 0.0 14 26.500 30.06 1.682 0.0 31.299 0.0277 0.868 Vel = 4.34 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams 'JFS Fire & Security Page 4 THE SHOPPELSAT CARLSBAD Date 05-10-2017 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 14 26.500 5.27 30.47 1.5 0.0 11.500 120 33.364 K= K@ HD2 to 0.0 0.0 0.0 15 26.500 60.53 1.682 0.0 11.500 0.1013 1.165 Vel = 8.74 15 26.500 5.27 30.99 1.5 T 9.9 37.333 120 34.529 K= K@ HD2 to 0:0 9.900 0.0 16B 26.500 91.52 1.682 0.0 47.233 0.2176 10.277 Vel = 13.21 16B 26.500 0.0 1.5 1 9.9 0.500 120 44.806 to 0.0 9.900 0.0 16 26.500 91.52 1.682 0.0 10.400 0.2176 2.263 Vel = 13.21 0.0 16 91.52 47.069 K Factor = 13.34 6 26.500 136.38 4 0.0 9.208 120 46.820 to 0.0 0.0 0.0 12 26.500 136.38 4.26 0.0 9.208 0.0049 0.045 Vel = 3.07 12 26.500 136.45 4 0.0 11.500 120 46.865 to 0.0 0.0 0.0 16 26.500 272.83 4.26 0.0 11.500 0.0177 0.204 Vel = 6.14 16 26.500 91.52 4 2E 26.334 78.333 120 47.069 to 1 26.334 52.668 0.0 17 26.500 364.35 4.26 0.0 131.001 0.0304 3.977 Vel = 8.20 17 26.500 0.0 4 3E 39.501 71.417 120 51.046 to 0.0 39.501 0.0 TRS 26.500 364.35 4.26 0.0 110.918 0.0304 3.367 Vel= 8.20 TRS 26.500 0.0 8 2E 42.282 38.000 120 54.413 to T 41.108 83.390 10.611 BRS2 2 364.35 8.249 0.0 121.390 0.0012 0.147 Vel = 2.19 BRS2 2 0.0 8 E 21.141 5.000 120 65.171 to 0.0 21.141 2.599 UG -4 364.35 8.249 0.0 26.141 0.0012 0.032 Vel = 2.19 UG -4 0.0 8 5E 105.706 218.250 120 67.802 to 0.0 105.706 0.0 UG1 -4 364.35 8.249 0.0 323.956 0.0012 0.393 Vel = 2.19 UG1 -4 0.0 8 0.0 10.000 140 68.195 to 0.0 0.0 0.0 UG2 -4 364.35 8.27 0.0 10.000 0.0009 0.009 Vel = 2.18 UG2 -4 0.0 8 0.0 33.417 150 68.204 to 0.0 0.0 0.0 DC1 -4 364.35 7.98 0.0 33.417 0.0010 0.032 Vel = 2.34 DC1 -4 0.0 8 5E 142.34 6.000 140 68.236 to 0.0 113.872 5.000 *Fixed Loss 5 DC2 -4 364.35 8.27 0.0 119.872 0.0009 0.108 Vel = 2.18 DC2 -4 H250 250.00 8 T 52.855 10.000 150 73.344 to 0.0 52.855 0.0 CON -4 614.35 7.98 0.0 62.855 0.0025 0.156 Vel = 3.94 0.0 CON 614.35 73.500 KFactor= 71.66 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary VFS Fire & Security Page 5 THE SHOPPELS AT CARLSBAD Date 05-10-2017 Fitting Legend Abbrev. Name 1/2 % 1 11/4 11/2 2 2% 3 31/ 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T NFPA 1390 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 STANDARD RESPONSE: / - A UTOMA TIC SPRINKLERS U (Z) GLSERIES N'QVF L_11_)[ ~L UPRIGHT PENDENT FIRE SPpNLERtORPORATOr VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Standard Response GL Series Sprinklers are a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. While the Standard Response Sprinkler provides an aesthetically pleasing appear- ance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and fin- ishes to meet varying design requirements. Standard Response STANDARD RESPONSE Sprinklers should be used advisedly and under the direction of UPRIGHT CONVENTIONAL approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that I contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is I distributed in an approved pattern depending upon the deflector style used. STANDARD RESPONSE The sprinkler and escutcheon are not factory assembled. PENDENT VERTICAL Assembly is done in the field. SIDEWALL TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (790C), 200°F (93°C), 286°F (141°C), 360°F (182°C) .3 500°F(260°C)Available Upon Request Without Approvals J Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) STANDARD RESPONSE Maximum low temperature glass bulb rating is -67°F (-55°C) LPCICE HORIZONTAL Frame - bronze • Deflector - brass • Screw - brass HORIZONTAL SIDEWALL Lodgement Wire - stainless steel • Bulb seat - copper SIDEWALL Spring - nickel alloy• Seal - teflon Bulb - glass with glycerin solution, 5mm size Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES I BULB COLOR J N.F.P.A. MAXIMUM I CEILING TEMPERATURE ORDINARY I 35'F/1 -15"F 5' C58 ORANGE/RED 100'F 8C 1 INTERMEDIATE 175 F:2OOF 7C93C YELLOW/GREEN 100 0 66 C HIGH 286I 11C BLUE 225C 107C EXTRAHIGH 3600 82 C I MAUVE 300T 14'C ULTRAHIGH 560C - 260 C - BLACK 4751 246C APR 2017 GFS-100b (Formerly A-65) 7/U' MAX. ORDERING INFORMATION SPECIFY Quantity Model• Number Style" Orifice Thread Size Temperature. Finish desired Quantity - Wrenches/Recessed Wrenches - P/N 325390/325391 (1/2"); P/N 312366/325401 (L.O.) Quantity Protective Caps - P/N 327109-CAP (Friction Fit Recessed) FIRE 4 4NKLC0RF:)FAfltJ7 APR 2017 STANDARD RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT • PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL ° CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2 NPT(l5mm) 21/4 (57cm) Factory Bronze 4.2 (60 metric) 1/2"NPT(15mm) 2 1/4 (5.7cm) Chrome 5.6 (80 metric) 1f2 NPT (15mm) 2 1/4 (57cm) White Polyester' 8.0 (115 metric) 1/2"NPT(15mm) 2 1/4'(5.7cm) Black Polyester 2.3 8.0 (115 metric) 3/4"NPT (20mm) 2 7/16 (6.2cm) Wax Coated 2.1.1 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. 'HORIZONTAL SIDEWALL IS 29/16". 'WAX COATING cULus LISTED UP TO 200"F (93°C) ONLY. 'FINISHES AVAILABLE ON SPECIAL ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD cULus FM LPC CE NYC-DOB MEA 101-92-E -'--- 135°F 155°F 175°F - 200°F **286F 11360°F (57°C) (68°C) (79°C) (93°C) (141°C) (182°C) GL2861 2.8 LH X X X X X X X X GL4261 42 LH X X X X X X X X UPRIGHT GL5661 56 ALL X X X X X X X X X X X GL8161 8.0" ALL X X X X X X X X GL8164 8.0 ALL . X X X X X X X X X X X GL2851 2.8 LH X X X X X X X X PENDENT GL4251 4.2 LH X X X X X X X X RECESSED GL5651 5.6 ALL X X X X X X X X X X X PENDENT GL8151 8.0° ALL X X X X X X X X GL8156 8.0 ALL X X X X X X X X' X X X VERTICAL GL5675 5.6 LH X X X X X X X X SIDEWALLt 0L8176 8.0 LH X X X X X X X HORIZONTAL GL2870 2.8 LH X X X X X X X X SIDEWALL GL4270 4.2 LH X X X X X X X X RECESSED GL5670 5.6 LH/OH X X X X X X X X X HORIZONTAL GL56710 5.6 LH/OH X X X X X X --- --- X X SIDEWALL GL8171 8.0 LH/OH X X X X X X X CONVENTIONAL GL5668 5.6 LH/OH X X X X X X --- --- X X (OLD STYLE) GL8169 8.0 LH/OH X X X X X X --- --- X X 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. 'BRASS FINISH ONLY WHEN RECESSED §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4' TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. "NO FM APPROVALS FOR RECESSED aINSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. "NO FM APPROVALS fPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. OR ORDINARY HAZARD tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. LH: LIGHT HAZARD 500°F (260°C) AVAILABLE UPON REQUEST WITH NO APPROVALS. ALL: ALL HAZARDS °1/2"NPT, RETRO-FIT ONLY GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List), 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www,globesprinkler,com PRINTED U.S.A. GFS-100b (Formerly A-65) -------2 15/16" DIA.- - 2" DIR. MIN. HOLE IN CEILING 129/32- OIA. - -1" 1/2' REDUCER I kERT I N.