Loading...
HomeMy WebLinkAbout1808 ASTON AVE; 220 | 230 | 235; FPC2019-0214; Permit16 sity of Carlsbad Print Date: 10/24/2022 Permit No: FPC2019-0214 Job Address: 1808 ASTON AVE. # 220/230/235, CARLSBAD, CA 92008-7365 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121200700 Track #: Applied: 09/12/2019 Valuation: $0.00 Lot #: Issued: 09/25/2019 Occupancy Group: Project #: Finaled Close Out: 10/25/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Project Title: Description: ASTON VIEW CORPORATE CENTER -FIRE ALARM DUCT DETECTORS (5) Applicant: FPContractor: SCHMIDT FIRE PROTECTION INC SCHMIDT FIRE PROTECTION CO INC GORDON SWOPE 4760 MURPHY CANYON RD 4760 MURPHY CANYON RD SAN DIEGO, CA 92123-4321 SAN DIEGO, CA 92123-4321 (858) 279-6122 (619) 871-9753 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I I I I I I I I I I trcjO19- O2j + Schmidt Fire Protection En., Inc. — 4760 MURPHY CANYON RD • SAN DIEGO, CA 92123. (858) 279-6122 • FAX (858) 279-3583 ASTON VIEW CORPORATE CENTER 1808 Aston Ave Carlsbad, CA 92008 Selective Suites 200/230/235 Wiring of Added Duct Detectors SUBMITTAL PACKAGE Design by: Gordon E. Swope SET (NICET Level-IV #078621) (619) 871-9753 gordon@'schmidtfireprotection.com.com Date September 6, 2019 .1 I I I I I I I I I I I coca" 9mU em - f T1 id f I 7M Al - . ;ii!l1I M2 SAM -------- - VjIu 1j owpo - _i--_- _,11 -- -- I 40 -=::— -- Ur I -- - Ilk :ie' .i PuJ ttIU fl' n i ti -r-t:) r j -, • •44 k u 1 t a- ULLJ - .• V. •'ICAi TW _ 01. ru r1 can. -- ____ - j_ii__-JI_ _Lf4INMrNF - - -- --4--- no" Won r I o0vogammouxam CA" ow" AMSVVM mmvmftlm .JI)JIL .Jj CHCAZQ1I4 1DG A$TON 'V ucn 4ZU ceme tnC iatt 14 r4* I DJ" I won - - I wmnvra f I v :;• - I Lla* FOR INFORMATION ONLY! ARIES NETLink TM Ap ( fKidde Fire Systems Multi-Loop Intelligent Fire Alarm-Suppression Control Unit Effective: July 2014 FEATURES Intelligent addressable multi-loop, suppression-focused control unit Triple R redundancy provides maximum protection against inadvertent release Out-of-the-box features: - 2 SLCs with 255 unrestricted addresses each (510 total) - 4 x 40 Display-Keypad - 4 Programmable soft-switches - 2 NACs and 2 R-NACs - 3 Programmable and I Trouble Form-C Relays - 2 Auxiliary Power Outputs, 2 amps each - USB ports for PC and printer I- - RS-232 ports for graphics - 1201240V, 50/60 Hz AC input - 5.4 A Power Supply Unit - Charging Capacity of 165 AH (UL) and 132 AH (ULC) DESCRIPTION - CONTROL UNIT - RS-485 Annunciator bus The ARIES NETLinkTm is one of the most technologically - 2-Tier or 3-Tier NEMA I Enclosure - fits between 16"studs advanced intelligent fire alarm suppression-focused con- Suppression systems include: trol units available to the industry today. It combines the - FM-200, FE-13, 3M Novec 1230 Fire Protection Fluid, high quality, system reliability, and flexibility required by mod- Carbon Dioxide, Argonite & Halon Clean Agents ern commercial, high-tech and industrial applications in an - Dry Chemical, Wet Chemical aesthetically-pleasing and physically-robust package. Its - Water-Mist - Sprinkler Supervisory Service modular architecture enables easy field expansion from the - Deluge, Pre-Action, Foam, Foam-Water Systems base 2-SLC unit that supports 510 addressable devices (255 Modular and expandable per circuit) to an 8-SLC system that supports 2,040 address- - From 3 to 8 SLCs (2,040 addresses) able devices; 130,560 addresses available for a 64-node net- - Up to 96 relays work. - Up to 72 release/NAC circuits The ARIES NETLink is compact, fits between wall stud - Combinations of the above and/or functional modules dimensions, and is designed to be quick and easy to Networkable up to 64 nodes (130,560 addresses) install. Cutting edge technologies incorporated in the elec- Flexible programming High level serviceability and diagnostics tronics design enable diagnostics for time-efficient com- - Ground fault detection by circuit missioning. - 10,000 event log capacity Main Controller Board - MCB - Internet connectivity with e-mail notification feature The ARIES NETLink's main printed circuit board contains Modbus RTU, Modbus TCP/IP, BACnet MSITP and BACnet the system's central processing unit (CPU) and all of the IP compatibility Backwards compatible with installed investment primary circuits. The MCB is the heart of the system, con- - SmartOne SLC devices & protocol trolling the operation and supervision of all the system - Kidde Control Heads modules and software. It receives loop device data, pro- - Actuators cesses the data based on pre-programmed instructions, - Legacy PEGAsys panels via simple retrofit kit and transmits output commands to the output modules, Seamlessly integrated HSSD, ASD and LHD field devices, and display(s). The MCB is mounted to the Pluggable terminal blocks enclosure using special design hinged standoffs which User Interlace 4 x 40 display supports 4 languages: permit the board to swing left and enable easy access to English, French Canadian, Spanish and Portuguese the PMU/PSU assembly behind. French Canadian, Spanish and Portuguese Language kit Approvals/Listings*: User Interface - FM Approved to ANSI/UL864 The user interface consists of a built-in keypad and display - UL Listed No. S2422 which provide physical means by which an operator and/or - cUL Listed No. S2422 installer performs system functions, enters the security - CSFM Approved: No. 7165-1076:0195 password, operates soft keys, navigates the system - California OSHPD Special Seismic Certification Pre- menus, configures and tests the entire ARIES NETLink Approval, No. OSP-0286-10 system. The LCD display supports four languages: English, - NYC Fire Department Certificate of Approval: No. 6092 French, Spanish, and Portuguese (selected from the top- - City of Chicago Acceptable for Class I Applications RoHS compliant level menu). I SmartOne Signaling Line Circuit (SLC)-255 devices per circuit (No restrictions on Device Type) th ION PHOTO THERMAL _ _ (CPD-7052) (PSD-7152) (THD-7252) 11 0 1 1 Abort I LJ LHS AlarmLine OAF Station Manual M ORION xr J 4+ Release AIR-Intelligence High Sensitivity Air Sampling Smoke Detectior Remote Disnlv Detection Control Modules _______________________ (RDCM5),1-15 Remote J1 Releang LED Annunciator Module I I ASM Horns/ Relay Modules (LAMs), Suppression Release Strobes Module 1-16 - HVAC - Shutdowns - Doors and Dampers - Elevator Recall Release j I. 00, Additional SLCs 1... Relay Outputs ....................... Internet Communications Module (1CM) r..P .......................P"BACnet/Modbus ....................... USB and/or Serial Connection for Laptop and Printer Interface I S. ARIES NETL'nk Control Panel Card Cage J Signal Line Circuit (SLC) Card Network Interface Card (N IC) Relay Card City Tie Card Release/Notification Appliance Circuit (R-NAC) Card Digital Alarm Communicator Transmitter (DACT) Figure 1. Modular Design to Meet the Most Demanding Applications -2- Figure 2. Main Controller Board and User Interface MAIN CONTROLLER BOARD SPECIFICATION MCB Signaling Line Circuits Number of Circuits: Two Device Capacity: 255 devices per SLC Device Type Restriction: None Wiring Classes: Class A, B or X T-Tapping Allowed: Class B only Circuit Voltage: Nominal 24 VDC Maximum Line Resistance: 40 ohms per loop Maximum Capacitance: 0.5 pF Maximum Current: 350 mA (short circuit) Wiring Specifications: Twisted #I4AWG - #18AWG, unshielded, low-capacitance wire with a nominal wire-to- wire capacitance of approximately 20 pf. Relay Form: MCB Notification ADpliance Circuits Rating: Number of Circuits: Two Compatible devices: 24 VDC polarized horns, strobes, bells, etc. Wiring Classes: Class A or B Power Limited: Yes Synchronized Strobes: Yes, configurable -3- MAIN CONTROLLER BOARD SPECIFICATION (Continued) Non-Synchronized: 2.OA Synchronized: 1.5 A 28 VDC I 20 VDC 10 K, 5%,1/2 W 2 V at End-of-Line MCB Release/Notification Anoliance Circuits Number of Circuits: Two Individually Configurable for Notification or Release: Yes Notification Specifications: Same as NAC Release Specifications: Compatible devices: Kidde Control head: max 1 Water Mist Solenoid valve: max 1 FM Group A, B, D, E, F, G, I, J or K Solenoid: max 1 Metron actuator: -P/N 83-132500-500 max 1 -P/N 83-131082-001 max I Device type configurable: Yes, with device on- time after activation Wiring Classes: Solenoids: Class A or B Actuators: Class B Power Limited: Yes, requires In-Line diode device Maximum Output Circuit Terminal Voltage: 28 VDC End-of-Line Resistor: 10K, 5%,1/2 W Allowable Voltage Drop: 2V MCB Relays Number and type 3 Programmable and 1 Trouble Relay Form-C (1 NO + 1 NC) 3A @ 30 VDC/120 VAC Maximum Output Current: Maximum Output Circuit Terminal Voltage: Minimum Output Circuit Terminal Voltage: End-of-Line Resistor: Maximum Allowable Voltage Drop: MAIN CONTROLLER BOARD SPECIFICATION (Continued) POWER SUPPLY & MANAGEMENT SPECIFICATION MCB RS-232 Serial Potts Number of PMUs per Minimum: 1 I Number of Ports: 2 control unit Maximum: 4 Specifications: Bi-Directional 9600 Number of PSUs per PMU Minimum: 1 Baud, 8 Data Bits, 1 Maximum: 2 i Stop Bit, No Parity Primary AC Input Power: I IPSU: 12O VAC, 50/60Hz, MCB RS-485 Annunciator Port 3.2 A Number of Ports: 1 240 VAC, 50/60 Hz, I Compatible Devices: 1.6 A RDCM Max. 15 devices 2 PSU: 120 VAC, 50/60 Hz, R-LAM Max. 16 devices 6.4 A ATM-L Max. 16 devices 240 VAC, 50/60 Hz, ATM-R Max. 16 devices 3.2 A Compatible Device 31 in any order Allowable Input Voltage 115 ± 5% VAC I Maximum: Variation: 230±4%VAC Wiring Type: Twisted, shielded, low- Secondary DC Output: capacitance fire alarm I PSU: 5.4 A @ 27.6 VDC wire 2PSU: 10.8 A @ 27.6 VDC I Wiring Minimum Size: AWG 18 Voltage Selection: Slide switch on PSU Maximum wire length: 4,000 ft. (1,219 m) Trouble Relay Contact 1.0 A @30 VDC Rating: (resistive) I MCB USB Device Ports: AC to Battery Transfer Number of Ports: 2 Voltage: 120 VAC: 109 VAC I Power Supply 220 VAC: 200 VAC The ARIES NETLink Control Unit requires a minimum of Battery Charging Circuit 27.0 VDC (nominal) one Power Supply Unit and one Power Management Unit Voltage: (PMU) Board for operation. Additional Power Supply Maximum Battery Charging Units may be added, based on calculated power require- Circuit Current: ment (refer to Battery Calculations in the ARIES NETLink I PSU: 4 A Installation, Operation, and Maintenance Manual, P/N 2 PSU: 8.9 A 06-237058-001). I Allowable Battery Type: 2 x 12 VDC Sealed One PMU board is needed to control up to 2 Power Sup- Lead-Acid Only ply Units. The ARIES NETLink Control Unit design offers Maximum Battery Capacity: UL/FM: 165 AH optional Power Supply Units and Power Management I ULC: 132 AH Unit (PMU) Board to expand the available power to meet Auxiliary Outputs: 2 per PMU, additional power requirements. power-limited I Each enclosure of the ARIES NETLink Control Unit can Auxiliary Output Operating 19.2 -27.6 VDC provide 20 Amps of power supply capacity and the sys- Voltage Range: tern can charge up to 165-AH batteries for UL applica- Auxiliary Output Maximum 2 A @ 470 pF max. tions and 132-AH batteries for ULC applications. Current: per output I -4- BackDlane & Card Cage The Card Cage is a metal frame which supports and secures up to six Expansion/Functional Cards plugged into the Backplane. The frame is fixed to the Backplane and mounts to the enclosure in the second- or third-tier positions. A fully expanded ARIES NETLink system can accommodate a maximum number of four Card Cages or 24 card slots in total. Unlike installation intensive control units, the ARIES NETLink features virtually plug-and-play architecture in that the control unit is intelligent enough to detect the type of card plugged in. 0 Signal Line Circuit (SLC) Card 0 Network Interface Card (NIC) Relay Card City Tie Card Release/Notification Appliance Circuit (R-NAC) Card Digital Alarm Communicator Transmitter (DACT) Figure 3. Backplane and Card Cage CARD CAGE SPECIFICATION Module Capacity each: Maximum 6 Number of Card Cages: Maximum 4 per MCB Number of Expansion/ Maximum 24 per MCB Functional cards: Signaling Line Circuits - SLC The Main Controller Board incorporates two SLC circuits. At the rate of one SLC per expansion card, up to six addi- tional circuits can be included in one control unit. The Expansion Card occupies a single slot in the Card Cage Assembly and plugs directly into the backplane. All SLC's are suitable for Class A, Class B and Class X wiring. A disconnect switch provides the means to physi- cally isolate the circuit from its associated field wiring. Communications LEDs indicate data transmission (green) and reception (yellow) and a Status LED indi- cates module energized state (green) and de-energized state (yellow). The ARIES NETLink is compatible with all SmartOne protocol based devices. The SmartOne communication protocol is called Broadcast Index Polling (BIP). The BIP enables each of the 255 initiating device on the SLC to communicate with the panel on an individual basis in an intelligent system. BIP imposes no limitations on the mix of automatic initiating devices and monitor/control mod- ules on the signaling line circuit. Each SmartOne initiat- ing device has a microprocessor, memory, and decision- making algorithms to interrupt normal control-unit com- munications and initiate an alarm signal. The BIP com- munication protocol divides the potential 255 addresses on the SLC loops into 8 groups of 32 addresses each and the panel constantly samples the groups for fire signa- tures. Once a fire signature is detected, the panel nar- rows down to the group with the SmartOne device(s) initiating the signature and further to the particular address initiating the fire signature. The SmartOne smoke detectors manage their individual drift compensation routines, and have pre-alarm and alarm thresholds that are configurable in 0.1 percent-per- foot increments throughout the entire range of listed sen- sitivities. The ARIES NETLink can dynamically adjust the smoke detector alarm thresholds as the result of one or more alarm-initiating events to confirm that a fire requir- ing the rapid action of an associated extinguishing sys- tem has occurred. SmartOne smoke detectors can also be configured for non-latching operation that requires them to measure smoke signatures in excess of their alarm thresholds for the entire pre-discharge time period in order to discharge the extinguishing system. This pre- vents a transitory event that mimics a smoke signature such as the leakage of air-conditioning fluid from acci- dentally discharging the extinguishing system. SmartOne heat detectors have pre-alarm and alarm thresholds that are programmable in 1°F intervals. SLC EXPANSION CARD SPECIFICATION Number of Cards: Subject to slot availabilty, max 6 per MCB Circuit Specifications: Same as SLC on MCB NACs & R-NACs. The Main Controller Board incorporates two Notification Appliance Circuits and two user-configurable Releasing! Notification Appliance Circuits. The system can be expanded by adding R-NAC cards to the backplane. The Expansion Card occupies a single slot in the Expansion Card Cage Assembly and plugs directly into the back- plane. Each R-NAC card provides three Releasing-Notifi- cation circuits similar to the R-NAC circuit on the MCB. Given adequate power, the number of R-NAC Expansion Cards in a system is limited only by the availability of card slots -which itself is limited to 24. -5- Notification Appliance Circuits can be wired as Class A or Class B and support 24 VDC polarized appliances such as horns, strobes and bells. Strobes can be either syn- chronized or non-synchronized. The Releasing Circuits can be wired as Class A or Class B and configured to activate agent control heads. The cir- cuit-on time is configurable from 55 microseconds, 90 seconds, 10 minutes, 15 minutes, or On-To-Reset, dependant on the release device and suppression sys- tem. While the circuits are power limited, utilizing this option for releasing requires the use of a field In-Line Release Device - separate for solenoids and actuators. An NFPA-72 compliant disconnect switch provides the means to physically isolate the circuit from its associated field wiring. R-NAC EXPANSION CARD SPECIFICATION Number of Cards: Subject to slot availability, max 24 per MCB Number of Circuits Per Card: Three Circuit Specifications: Same as R-NAC on MCB Triple Redundancy Protection Unlike some generic fire alarm control units adopted for releasing service, at its core the ARIES NETLink is suppression-focused. Featuring the exclusive Triple-R redundancy safeguard wherein no single component fail- ure or combination of abnormal operating conditions, including main microprocessor failure, is allowed to result in accidental release activation, the ARIES NETLink provides the same high quality, dependability and maxi- mum protection against inadvertent release that have been the hallmark of Kidde suppression panels for decades. The Triple-R system requires that in order to activate a release, the main microprocessor issue two release commands of opposite polarity via separate signaling channels and that these commands combine with a signal from the control unit's watchdog timer to confirm the microprocessor operation. The Triple-R sys- tem ensures that electrical transients or disturbances such as power surges that could interfere with the opera- tion of the main microprocessor will not inadvertently activate the connected suppression system. The result is a more robust and reliable suppression control unit. Relays The Main Controller Board incorporates 3 programmable Form-C Relays and 1 Form-C Trouble relay. The Expan- sion Card occupies a single slot in the Card Cage Assembly and plugs directly into the backplane. The sys- tem can be expanded by adding Relay cards to the back- plane. Each Relay card provides four programmable Form-C relays similar to those on the MCB. The number of Relay Expansion Cards in a system is limited only by the availability of card slots - which itself is limited to 24. Each relay is independently-driven and can be pre-pro- grammed to change state for all states of Alarm, Trouble and Supervisory conditions. Relays are normally de- energized, unless configured for Trouble. A Trouble relay is energized upon startup and changes state for any Trouble event, including failure of the Main Controller Board. R-G-Y status LEDs are provided. Contact ratings are 3A at 30 VDC or 120 VAC. RELAY EXPANSION CARD SPECIFICATION Number of Cards: Subject to slot availability, max 24 per MCB Number of Relays Per Card: Four Relay Specifications: Same as Relays on MCB City Tie Card The optional City Tie Card provides connection and oper- ation for three independently operated signaling circuits used to connect to Municipal Tie inputs as either Local Energy output, Shunt-Type Master Box output or Reverse Polarity output. The City Tie Card occupies a single slot in the Card Cage Assembly and plugs directly into the backplane. The ARIES NETLink allows one City Tie Card per control unit. CITY TIE CARD SPECIFICATION Number of Cards: Max 1 per control unit Number of Circuits Per Card: Three Local Energy Type: 24 VDC @ 550 mA maximum Shunt-Type Master Box: 24 VDC @ 5 A maximum Reverse Polarity Type: 24 VDC @ 100 mA maximum Networking For large areas or campus style-applications, ARIES NETLink control units can be networked into a powerful system capable of supporting 130,560 addressable devices. The ARIES NETLink has the capability to provide true peer-to-peer networking of up to 64 control units. Added functionality is provided when the Remote Display Control Module (RDCM) are connected to the individual control panels and hence into the interconnec- tion scheme. The network is capable of performing fire- alarm and/or suppression system operations on a net- work-wide basis: - Event initiation - Protected-premises local and/or remote event annunciation - Occupant notification via audible and visible sig- naling appliances - Process/equipment control to activate safety procedures - Fire extinguishing system release - Off-premises transmissions to central station or fire department The network provides several convenient interconnect programming schemes wherein control panels can be configured individually or within created groups of control panels. When utilizing the grouping configuration, the interconnection automatically provides shared alarm and trouble responses. The programmable shared responses are: acknowledge, silence, reset, event logging and logic statements. Operator events can be activated into the interconnection via the control panels or any annunciator. A location address and programmable description is used to identify the panel initiating the event. The ARIES NETLink meets the Display and Control Cen- tre requirements of ULC S527-11. When configured for "ULC Operation" and networked with other control units, any control unit can become the Display and Control Centre Node. The first node to perform a control type operation - event acknowledge, system reset, system silence or fire drill - gains exclusive control of the net- work. When a node is in control, all other nodes display an indication of the node in control and, as long as key- pad operations continue to be performed, that node remains in control. Control can be relinquished after an inactivity period or another node requests control (by pressing an operational button and selecting "REQUEST CONTROL"). Network Interface Card - NIC The Network Interface Card regenerates and boosts net- work communications between control units and electri- cally isolates the networked units from each other. All ARIES NETLink units must contain a NIC to be net- worked to one another. The NIC occupies a single slot in the Card Cage Assembly. Using the NIC, the control units transmit and receive messages via R5485 format over a twisted pair. An optional Fiber Optic Converter Module (FOCM), in addition to the NIC, allows connectivity via a fiber optic medium. The networking structure supports a mixture of fiber-optic and twisted-wire interconnections among networked control units. The network structure also supports up to 4,000 ft. long 18 AWG of copper wire between nodes (control units). NETWORK INTERFACE CARD (NIC) SPECIFICATION Number of Cards: Max 1 per control unit Number of nodes in network: Maximum 64 Wiring Classes: Class A or Class B Data Ports: EIA/TIA-485 Baud Rate: 38,400 baud Recommended Wiring: AWG 18, twisted, shielded, pair Maximum Recommended 4,000 ft. (1,219 m) Length: Fiber Optic Converter Module -FOCM A fiber-optic option is available for network applications (NIC card also required) with communication paths greater than 4,000 ft. or where excessive electrical noise is present. The FOCM is a bi-directional, externally-pow- ered unit which is wall mountable in the standard ARIES NETLink remote enclosure. One FOCM is required at both interconnected ARIES NETLink control units for a single communication channel. For short transmission distances (under I mile), such as within a building or on a campus, multi-mode optical fiber (MM fiber) can be used (62.5 Am core size/125 Am clad- ding diameter). For longer transmission distances (up to 12 miles), single-mode (SM fiber) can be used (8.3 Am core size/I 25 jim cladding diameter). Either type of fiber may be used and both connect to the ARIES NETLink power and RS-485 data lines in the same fashion. The FOCM is shipped standard with one converter chan- nel. For greater communication security and redundancy, a second converter channel may be added. This is most effective if the second channel is installed in a different pathway from the first. FIBER OPTIC CONVERTER MODULE (FOCM) SPECIFICATION Operating Voltage: 24 VDC Operating Current: 175 mA Data Ports: EIA/TIA-485 Max. Recommended I mile (with no more than Length for MM Fiber: 6.4 dB/mile cable attenuation) Max. Recommended 12 miles (with no more Length for SM Fiber: than 1.66 dB/mile cable attenuation) Baud Rate: 38,400 Baud Temperature Range: 01 to 50°C -7- I 1 FIBER OPTIC CONVERTER MODULE (FOCM) SPECIFICATION (Continued) Humidity Range: 0 to 93% RH, non-condensing Enclosure Dimensions 7-1/2 x 12-3/4 x 2-3/4 (in.) (HxWxD): 191 x 324 x 70 (mm) Digital Alarm Communicator Transmitter -DACT The communication capabilities of the ARIES NETLink control unit are enhanced with an optional DACT which transmits system status over phone lines to a Central Station. The DACT card includes a built-in modem and two Loop Start Public Switched Telephone Network (PSTN) connections. Status LEDs are provided to indi- cate data transmission (green) and reception (yellow). An ARIES NETLink system allows one DACT Card per con- trol unit. The DACT card operates on 24 Vdc and sup- ports SIA DC-05-1999.09 Ademco Contact ID and SIA DC-03-1990.01 (R2003.10) protocols. DIGITAL ALARM COMMUNICATOR TRANSMITTER (DACT) SPECIFICATION Number of Cards: Max 1 per control unit Operating Voltage: 24 VDC Operating Current: 37 mA Electrical Interface: PSTN line using a RJ45X phone jack Supported Protocols: SIA DC-05-1999.09 Ademco Contact ID SIA DC-03-1990.01 (R2003.1 0) Compatible Digital Alarm Sur-Gard System I, Communicator Receivers Sur-Gard System Ill (DACRs): and Osborne Hoffman Model 2000E Internet Communications Module -1CM The Internet Communications Module (1CM) can be used to access the ARIES NETLink System via the Internet to view system status and current events and to download the history log. The 1CM can be programmed to transmit up to five e-mails upon the occurrence of any unsolicited event in the system. The e-mail message embeds a link with the IP address of the control unit that sent the mes- sage for instant access to the remote system. The 1CM can be accessed using any standard Web browsing pro- gram and requires no special proprietary software. The 1CM also allows the ARIES NETLink Control Unit to report as a slave device via the Modbus TCP/IP Protocol to a master monitoring system for automated process control. INTERNET COMMUNICATIONS MODULE (1CM) SPECIFICATION Operating Voltage: 24 VDC Operating Current: 42 mA Operating Environment: 320 to 120°F (00 to 49°C) 0-90% RH, non- condensing Data Port: RJ45 Supported Field Ethernet - Local Area Protocols: Network or Wide Area Network (LAN or WAN) Modbus/BACnet Interface The Modbus/BACnet Interface module provides protocol translation between the ARIES NETLink communication protocol and the communication protocol of an external monitoring system such as a building automation system. The Modbus/BACnet Interface module converts the ARIES NETLink Communications Protocol to BACnet Protocol. The unit is wall mountable in the same ARIES NETLink standard remote enclosure. The communication flow is one-way from the ARIES NETLink network to the external monitoring system. The single module supports systems with up to 4 SLCs. For systems including more than 4 SLCs, a second (Add-On) module is required. Modbus/BACnet SPECIFICATION Electrical 6-pin Phoenix connector, Connections: RS232 3-pin Phoenix connector, R5485 Ethernet-1 0/100 port Enclosure Dims 7-1/2 x 12-3/4 x 2-3/4 (in.) (HxWxD): 191 x 324 x 70 (mm) Operating Voltage: 9-30VDC or 12-24VAC Operating Current: 150 mA @ 12VDC Operating Temperature: -40F to 187F (40C to 85C) Humidity: 5 - 90% RH, non-condensing Data Ports: RS232, Ethernet Max. RS232 Cable Length: 50 ft. (15.2 m) Supported Baud Rate for BACnet MS!TP: 9.6 - 76.8K baud I 1 I I Enclosures The ARIES NETLink offers two enclosure sizes, 2-Tier and 3-Tier, for both main and expansion enclosures. The enclosures accommodate the MCB, PMU/PSU, Expan- sion Card Cages and Batteries. The enclosures are sized to fit between standard 16"-spaced wall studs and can accommodate a pair of 12 VDC12-AH or 17-AH SLA batteries (max. 40-AH). The enclosures are painted red, rated NEMA 1 and constructed from 16 AWG cold rolled steel per ASTM A-366. All Kidde enclosures utilize a common key. Despite its compact dimensions, the enclo- sure allows a minimum of 1.5 in. (38 mm) of wiring space between the wall and any wiring terminal. Multiple knock- outs provide flexibility in wiring entry. Dead Front Covers A sheet-steel dead-front cover may optionally be mounted between the door and electronics to prevent unwanted access to the electronics. With the dead-front installed, an operator has access only to the user inter- face. A blanking plate (included) may be removed if an integrated LED Annunciator is present. The dead front is typical in ULC/cUL applications. Enclosure Trim Ring A sheet-steel red-enamel finished trim ring may be mounted around a semi-flush ARIES NETLink enclosure to enhance the Control Unit's aesthetic appeal after installation. Material of Construction: 16 gauge (0.053 in. or 1.35 mm) rolled sheet steel Enclosure Rating! NEMA 1 Degree of Protection: Color: Red Enclosure Dimensions (HxWxD): 3-Tier: 31-1/2 x 14-3/8 x 5-3/8 (in.) 800 x 365 137 (mm) 2-Tier: 22-1/2 x 14-3/8 x 5-3/8 (in.) 572 x 365 x 137 (mm) Dead Front Dimensions (HxW): 3-Tier: 31-1/3 x 14 (in.) 796 x 356 (mm) 2-Tier: 22-5/8 x 14 (in.) 567 x 355 (mm) Trim Ring Dimensions: 3-Tier: 17-1/2 x 34-5/8 (in.) 444 x 879 (mm) 2-Tier: 17-1/2 x25-5/8 (in.) 444 x651 (mm) CONTROL UNIT FEATURES Seamless Integration with Specialty Detectors SmartOne loop protocol interface cards enable the ARIES NETLink to seamlessly integrate with specialty detectors. AIR-Intelligence Air Sampling Smoke Detec- tors (ASD) and ORION XT High Sensitivity Smoke Detectors (HSSD) connect via Addressable Protocol Interface Cards (APIC) and PEGAsys Addressable Loop Modules (PALM) respectively and report pre-alarms and alarms in a manner analogous to SmartOne smoke detectors. AlarmLine Integrating Linear Heat Detector sensors (LHD) connect via AlarmLine Addressable Mod- ules (AAM) and report pre-alarms and alarms similar to a Smart-One heat detector. Fixed Temperature Linear Heat Sensor cables (LHS) connect via Addressable Input Modules (Al) and report point alarms. Field Programming Options The ARIES NETLink Configuration Software (ACT8000) tool is used to program the control unit for each individual site-specific application. Programming is for control-by- event scenarios and consists of entering a series of con- ditional control statements that logically join initiating points to control-unit-based outputs and remote control modules. Each SmartOne field device can be assigned a location message of up to 40 characters via the configu- ration tool. A USB Device Port is available to connect a laptop computer for application upload. The ARIES NETLink provides programming flexibility to prohibit the silencing of releasing service signals via the <SIGNAL SILENCE> key and to set the maximum auto- matic delay for the release operation in accordance with ULC S527-11 requirements. A Releasing Service Signal Silence Station is available for purchase and should be installed near the control unit in these applications. An AutoLearn routine that creates a general alarm (one- input-activates-all outputs) application can be invoked from the User Interface to speed the configuration pro- cess. A more sophisticated Auto-Setup routine which automatically configures the control unit for a typical waterless fire-suppression system can also be invoked. Automatic SLC Device Testing The ARIES NETLink features an exclusive automatic SLC device testing protocol. With this cutting edge super- visory technology, the control unit routinely checks all SLC devices in groups of 32 for operational status. If a group fails, the control unit then interrogates at lower level in that group and pin-points and reports the mal- functioning device on the User Interface within seconds. Duplicate Address Detection Electronic device addressing is via the Handheld Pro- grammer (HHP). The fully-digitized ARIES NETLink Control Unit protocol has the ability to monitor the SLC for devices with duplicate addresses. Should such dupli- cation be detected, the control unit displays these addresses on the User Interlace - thereby reducing the overall configuration time. -9- 1 I I Battery Life Tracking The ARIES NETLink software includes an optional Battery Monitoring Mode which can track battery lifetime from the original install date and emit an audible signal on the replacement due date. Annunciator Bus The Main Controller Board includes an RS485 bus which can communicate with up to a total of 31 Remote Annun- ciators. These include up to 15 RDCM Remote Display! Control Modules and up to 16 LED Annunciator Modules. This capability can be expanded to include up to 16 legacy ATM-R and ATM-L Annunciator Terminal Mod- ules. CONTROL UNIT ACCESSORIES Large Capacity Battery Cabinet An optional NEMA-1 surface-mount Battery Cabinet is available for a pair of up to 12 VDC 40-AH sealed lead acid batteries. The cabinet is designed to be located within 100 feet of the control unit. The red painted cabinet is constructed of cold-rolled steel as other available Kidde enclosures. The door is hinged on the left and includes the same lock and key used with all Kidde enclosures. Three conduit knockouts are provided at the top to accommodate either % inch or % inch standard electrical conduit fittings. REMOTE BATTERY ENCLOSURE SPECIFICATION Accommodates: Up to 2 x 12 VDC 12- AH or 17-AH Battery (max 40 AH) Material of Construction: 18 AWG (0.053 in. or 1.35 mm) rolled sheet steel Enclosure Rating/Degree of NEMA 1 Protection: Color: Red Enclosure Dimensions 12 x 20 x 8-1/4 (in.) (HxWxD): 305 x 508 x 210 (mm) REMOTE ANNUNCIATORS Remote Display Control Module - RDCM RDCMs are user interfaces that replicate the ARIES NETLink and can be located remotely from the main enclosure so as to accomplish system control from multi- ple locations. RDCMs display all system events and allow full system control and operator intervention via an LCD display, keypad, buzzer, five (5) system status LEDs and four (4) user-programmable soft-keys. A synchroni- zation signal output allows expansion of up to 15 RDCM units. RDCMs are wall mountable in their own discrete enclosures and operate on 24 VDC sourced from either the ARIES NETLink Auxiliary Power Output or listed external power supply. Figure 4. RDCM REMOTE DISPLAY CONTROL MODULE (RDCM) SPECIFICATION Number of RDCMs: Max 15 on Annunciator Bus Power Input: 150 mA maximum 24.0 VDC Input Capacitance: 100 pF max. PMU Trouble Relay Input: Short = normal; open = fault Synch In/Out: 3.3 VDC Logic Wiring Type: EIA/TIA-485, twisted unshielded pair, maximum capacitance 15 pF per ft. Wiring Minimum Size: AWG 18 Maximum wire length: 4,000 ft. (1,219 m) Remote LED Annunciator Module - R-LAM R-LAMs are annunciators that provide 48 independently programmable LEDs. Each LED is dual color (red and yellow) and has space available for an identification label. R-LAMs include three system-level LED outputs for Module Power, System Trouble and Signal Silenced. Also included are system-level input functional switches for Signal Silence and System Acknowledge/Self-Test commands. R-LAMs are mounted remotely from the main enclosure and utilize the same remote enclosures as do RDCMs. LED Annunciator Modules can also be mounted within the main ARIES NETLink enclosure for ULC/cUL applications. Figure 5. R-LAM I I I I I I I I I [1 1 I I -10- REMOTE LED ANNUNCIATOR (R-LAM) SPECIFICATION Number of Modules: Max 16 on Annunciator Bus; 15 if LAM integrated into Control Unit Power Input: 150 mA maximum © 24.0 VDC Input Capacitance: 100 pF max. PMU Trouble Relay Input: Short = normal; open = fault Synch In/Out: 3.3 VDC Logic Wiring Type: EIA/TIA-485, twisted unshielded pair, maximum capacitance 15 pF per ft. Wiring Minimum Size: AWG 18 Maximum Wire Length: 4,000 ft. (1,219 m) REMOTE ANNUNCIATOR ENCLOSURE SPECIFICATION Accommodates: 1 RDCM 1 R-LAM Material of Construction: 18 AWG (0.053 in. or 1.35 mm) rolled sheet steel Enclosure Rating/Degree of NEMA 1 Protection: Color: Red Enclosure Dimensions 7-1/2 x 12-3/4 x (H x W x D): 2-3/4 (in.) 191 x324x70(mm) RETROFITTING LEGACY INSTALLATIONS Legacy PEGAsys Control Unit Retrofit Kit Installed PEGAsys control units can be upgraded to ARIES NETLink level by utilization of a retrofit kit. The retrofit kit consists of ARIES NETLink electronics, power supply and a door for the installed PEGAsys enclosure. The kit enables the PEGAsys electronics to be replaced without disturbing the original enclosure-backbox and conduits; thus maintaining the customers' investment in devices, suppression and wiring. The retrofit door is sized for the PEGAsys enclosure while its window is aligned with the ARIES NETLink. ARIES NETLink RETROFIT KIT (P/N 76-800400-001) The retrofit kit consists of the following parts: Base Plate qty. I Base Plate Bracket qty. I Replacement Door qty. 1 Retrofit Installation Hardware qty. 1 PSU with wiring harness to qty. 1 PMU Board PMU Installation Hardware Kit qty. 1 MCB, complete with UI and mounting qty. 1 hardware MCB Installation Hardware Kit qty. I ARIES NETLink System Installation! qty. I Configuration Kit OPTIONAL ADD-ONS TO BOTTOM TIER OF LEGACY BACKBOX: (room for only one from list below) Card Cage Assembly with backplane, qty. 1 bracket, hardware and cables, P/N 76-800010-001 Additional PSU/PMU Assembly with qty. I bracket and hardware, P/N 76400030-003 Standby Batteries one pair Note: * The ARIES NETLink system is FM Approved, UL Listed, cUL Listed and approved/listed by various other agencies. For a complete description of approvals and listings please refer to the applicable installation instructions. ORDERING INFORMATION ORDERING INFORMATION (Continued) Part Number Description ARIES NETLink SYSTEMS 76-800100-001 ARIES NETLink Control Unit-3T 76-800101-002 ARIES NETLink Control Unit-3T-ULC 76-800200-001 ARIES NETLink Control Unit-2T 76-800201-002 ARIES NETLink Control Unit-2T-ULC 76-800101-001 ARIES NETLink Control Unit-3T-ULC 76-800201-001 ARIES NETLink Control Unit-2T-ULC 76-800102-001 ARIES NETLink Control Unit-3T-Chicago 76-800202-001 ARIES NETLink Control Unit-2T-Chicago EXPANSION ENCLOSURES 76-800100-003 ARIES NETLink Expansion Encl-3T 76-800200-003 ARIES NETLink Expansion Encl-2T ENCLOSURE TRIM RINGS 76-800100-004 ARIES NETLink Trim Ring-3T Enclosure 76-800200-004 ARIES NETLink Trim Ring-2T Enclosure 76-800300-004 ARIES NETLink Trim Ring-RDCM Enclosure EXPANSION CARDS 76-800011-001 ARIES NETLink SLC Card 76-6800012-001 ARIES NETLink Relay Card 76-800013-001 ARIES NETLink R-NAC Card 76-800016-001 ARIES NETLink City lie Card 76-800015-001 ARIES NETLink DACT Card 76-800017-001 ARIES NETLink 1CM Card 76-800014-001 ARIES NETLink NIC Card EXPANSION CARD CAGE 76-800010-001 ARIES NETLink Card Cage Assy 76-800010-002 ARIES NETLink Backplane Board REMOTE ANNUNCIATORS/MODULES 76-800300-001 ARIES NETLink Remote Display Control Mod- ule 76-800300-002 ARIES NETLink Remote LED Annunciator 76-200004-032 ARIES NETLink ATM-L LED Driver Module 76-200005-032 IARIES NETLink ATM-R Relay Driver Module STANDBY BATTERIES (order 2 for 24V) 06-115915-013 Battery, 12 Vdc, 7-AH 06-115915-047 Battery, 12 Vdc, 12-AH 06-115915-046 Battery, 12 Vdc, 17/18-AH 89-100052-001 Battery, 12 Vdc, 35-AH (requires large capacity battery cabinet) 76-600000-514 Large Capacity Battery Cabinet, Red 76-800030-006 ARIES NETLink Battery Tray Part Number Description EXTERNAL MODULES 76-800300-005 ARIES NETLink FOCM w/enclosure, for MM fiber 76-800300-006 ARIES NETLink FOCM w/enclosure, for SM fiber 76-800300-015 ARIES NETLink FOCM Add-On Converter Channel, for MM fiber 76-800300-016 ARIES NETLink FOCM Add-On Converter Channel, for SM fiber 76-800300-007 ARIES NETLink BACnet Module with enclosure 76-800300-017 ARIES NETLink BACnet Module Add-On Card REPLACEMENT ENCLOSURES AND COVERS 76-800101-005 ARIES NETLink Dead Front-3T 76-800201-005 ARIES NETLink Dead Front-2T 76-800100-101 ARIES NETLink 3T Main Enclosure 76-800200-101 ARIES NETLink 2T Main Enclosure 76-800101-101 ARIES NETLink 3T Main Enclosure ULC 76-800201-101 ARIES NETLink 2T Main Enclosure ULC 76-800300-101 ARIES NETLink Remote Display Enclosure MCB & KEYPAD/DISPLAY 76-800020-003 ARIES NETLink Replacement LAM Board 76-800020-001 ARIES NETLink Main Controller Board 76-800020-002 ARIES NETLink Keypad-Display POWER SUPPLIES 76-800030-001 ARIES NETLink PSU 120-240VAC 5.4A with harness to PMU Board 76-800030-002 ARIES NETLink Power Supply, 120-240VAC 5.4A without harness 76-800030-004 ARIES NETLink PMU Board 76-800030-003 ARIES NETLink Add -on Power Supply/PMU Assembly 76-800030-005 ARIES NETLink PMUAssy Mounting Bracket 76-800030-007 ARIES NETLink PMU Fuse Kit MISCELLANEOUS 76-800000-008 ARIES NETLink Installation Configuration Kit 76-800000-001 ARIES NETLink Installation-Hardware Universal 76-800000-004 ARIES NETLink Releasing Diode Kit 76-800500-001 ARIES NETLink Chicago Control Box 76-800000-002 ARIES NETLink Main Plexiglass Window 76-800000-003 ARIES NETLink R-LAM Plexiglass Window 76-800000-005 ARIES NETLink Bezel-Enclosure Door 76-800000-006 ARIES NETLink Harness Enclosure-to-Enclo- sure 76-800000-007 Language kit includes operator instructions, wiring diagram and interior door label in French Canadian, Portuguese and Spanish - 12- ORDERING INFORMATION (Continued) SmartOne SLC DEVICES Part Number Description 76-800000-009 ARIES NETLink Multi-Loop Seismic Conver- sion Hardware Kit for Enclosures ARIES NETLink Multi-Loop Seismic Conver- 76-800000-010 sion Hardware Kit for Large Capacity Battery Cabinet 76-800000-012 Overlay that converts text (non-LCD) on User Interface to Canadian French 76-800000-013 Overlay that converts text (non-LCD) on User Interface to Portuguese 76-800000-014 Overlay that converts text (non-LCD) on User Interface to Spanish 70-600000-100 Hand-Held Programmer RETROFIT KIT (order P/N 76-800400-001) The Retrofit Kit consists of the following parts: QbL 76-800020-001 ARIES NETLink Main Control Unit (MCB) PCB with user interface, communication and power harnesses to PMU 76-800030-004 Power Management Unit Board 1 76-800030-001 Power Supply Unit with wiring harness 1 to PMU Base Plate 1 Base Plate Bracket 1 Replacement Door and Window Assembly 1 Installation Hardware #6 nuts 4 #8 nuts 2 #10 nut 1 Self-threading screw 1 COMPATIBLE DEVICES SmartOne SLC DEVICES Part Number I Description 71-401001-000 Photoelectric Detector (retrofit only) 71-401004-000 Photoelectric Detector with Relay (retrofit only) 70-402001-100 Ionization Detector 70-401001-000 Ionization Detector (retrofit only) 70-401004-000 Ionization Detector with Relay (retrofit only) 70-404001-100 Heat Detector 70-400001-100 Flanged Detector Base 70-400001-101 Detector Base 70-400001-200 Detector-Base Adapter 70-400001-000 Detector Base (retrofit only) 70-403001-152 Duct Housing with Photoelectric Detector 70-403001-052 Duct Housing with Ionization Detector 70-403000-000 Duct Housing (retrofit only) 70-407008-001 Monitor Module (N/O) Part Number Description 70-407008-002 Monitor Module (N/C) (UL only) 70-407018-001 Monitor Module (N/O) (non-silicone) 70-407018-002 Monitor Module (N/C) (non-silicone; UL only) 70-407004-00 1 Monitor Module (N/O) (retrofit only) 70-408004-001 Control Module 70-408014-001 Control Module (non-silicone) 70-408001-000 Control Module without Mtg. Plate (retrofit only) 70-408002-000 Control Module with Mtg. Plate (retrofit only) 70-408003-000 Control Module with SS Mtg. Plate (retrofit only) 77-297103-000 PEGAsys Addressable Loop Module (Fits in ORION XT Detector) 73-100003-001 Addr. Alarmline Mod.(in NEMA-4 enclosure) 70-200200-001 Addr. Signal Module 70-200200-003 Addr. Signal Module 70-200200-002 Addr. Signal Module (on 6SB Detector Base) 74-200012-002 Isolator Module (single-gang mount) 74-200012-004 Isolator Module (detector-base mount) 70-600000-001 Remote Releasing Module (standard mount) 70-600000-002 Remote Releasing Module (in-cabinet mount) 76-333002-001 APIC for AIR-Intelligence ASDs 84-330002-001 Addr. Dual Action Pull Station with integral Model Al Addressable Monitor Module 84-878752-010 Suppression Abort Station (requires a Model Al Addressable Monitor Module) 84-878752-110 Abort Station fOr ULC applications (requires Model Al Addressable Monitor Module) 76-800600-101 Canadian Releasing Service Signal Silence Station (includes Faceplate with Key Switch, Backbox, and N.O. Model Al Addressable Mon- itor Module) RELEASING DEVICES Part Number Device "On" Time Max. per Circuit 890181 Momentary 1 895630 Momentary 1 899175 Momentary 1 87-120099-001 Momentary 1 90-487100-001 Momentary 48650001 Steady 1 06-118384-001 Steady 1 38-509834-001 Steady 1 38-509837-001 Steady 1 81-100000-001 Steady 1 897494-000 Steady 1 897494-530 Steady 1 06-118329-001 Steady Marioff D21070 Steady -13- .1 fKudde Fire Systems 400 Main Street Ashland, MA 01721 Tel.: 508-881-2000 Fax: 508-881-8920 wwwkiddefiresystems.com I RELEASING DEVICES Part Number Device "On" Time Max. per Circuit FM Group A Steady 1 FM Group B,D Steady 1 FM Group E,G Steady 1 FM Group F Steady FM Group I Steady 1 FM Group J Steady 1 FM Group K Steady 1 83-132500-500 Momentary 1 83-131082-001 Momentary 1 I Kidde is a registered trademark of Kidde-Fenwal, Inc. ARIES NETLJnk is a trademark of Kidde-Fenwal, Inc. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. K-76-800 Rev AF © 2014 Kidde-Fenwal Inc Addressable Contact Input Device K-76-701 fKidde Fire Systems Effective: January 2018 FEATURES Monitors N.O. or N.C/ Unpowered Contacts Full Digital Communications Remote LED Output Alarm Test from Control Unit Keypad DESCRIPTION UL Listed, ULC Listed, and FM Approved Class B, Style B Initiating Device Circuit Maximum 100 Ohm Loop Resistance (both conductors) The SmartOne® Addressable Contact Input Device (Al) is an intelligent field device with its own microprocessor, memory and electronics necessary to interface N.O. or N.C. unpowered con- tacts to Kidde intelligent control units. All of the electronics are contained in a high-impact polymer case, creating a very small and durable device for installation. A silicone-free version is avail- able for applications where silicone is not desired. Two types of Al's are available: an Al/NC for interfacing to nor- mally-closed devices and an Al/NO for interfacing to normally- open devices. The Al may be located up to 3,500 feet from the monitored device with #18 AWG wiring. An end-of-line-resistor is required for supervision of the wiring to the device. HELD PROGRAMMING System address, owner location message and reporting type are programmable via the compatible control unit configuration soft- ware program. The system address is a 3-digit number that uniquely identifies each device. The owner location message is a 40-character, alpha numeric message that describes the location of the device. The reporting type is assigned to the Al depending on the functionality of the device being monitored. SUPERVISION The Al continuously monitors the integrity of the following: Continuity of supervised wiring Power/Communications circuit voltage Internal power supply Memory data Faulty entering of data into Al memory STATUS LED A remote status LED may be connected to the Al. ALARM TEST Any or all Als can be tested by command from the compatible control unit. Results of the test may be printed. ORDERING INFORMATION SPECIFICATIONS IDC Wiring Style: Wired as NFPA 72 (2002 ed.) Class B, Style B Input Voltage: 24 VDC nominal Standby Current: 580 pA Max Alarm Current: 580 pA Max Max. Circuit Resistance: 100 Ohm (50 Ohm per conductor) Operating Environment: -31 to 151°F (-35 to 66°C) at 0 to 95% RH LED Pulse Modes: Normal: 9 second interval Trouble: LED is off Alarm: 2 second interval Acceptable Wire Size: 14, 16, 18 AWG The Al can be mounted in a North American 2-1/2-in. (64 mm) deep, 1-gang box or standard 4-in, square box, 1-1/2-in. (38 mm) deep with cover. COMPATIBLE CONTROL UNITS Kidde ARIES NETLink Kidde ARIES Fenwal FenwalNET 8000-ML Fenwal FenwalNET 6000 Chemetron MICRO MLX ChemetronI MICRO SLX Addressable Contact Input Device N.O 70-417008-001 Addressable Contact Input Device NO, non-silicone 70-417018-001 Addressable Contact Input Device N.C. 70-417008-002 Package of 10 End-of-Line Resistors 70-411001-005 This literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is published and presented without any guarantee or warranty whatsoever. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The fire suppression system design, instal- lation, maintenance, service and troubleshooting must be performed by trained, authorized Kidde Fire Systems distributors for the product to work correctly. If you need more information on this product, or if you have a particu- lar problem or question, contact: KIDDE-FENWAL, INC., Ashland, MA 01721 USA, Telephone: (508) 881-2000. K-76-701 Rev AA @2018 Kidde-Fenwal Inc EXPORT INFORMATION (USA) Jurisdiction: EAR US ECCN: EAR99 This document contains technical data subject to the EAR. fKidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: 508.881.2000 v',wwkiddefiresystems.com SYSTEM Z 4 SENSOR DUCTSD Duct Smoke Detector The System Sensor DUCTSD Series duct smoke detectors with a cover integrated smoke test port and flexible configurations provides efficient installation and maintenance. I Features 4-Wire Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 m/s to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Cover integrated smoke test port Plug-in sensor offers the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with an added 3/-inch conduit knockout One easy-access Test/Reset button Patented interconnect feature for multi-fan shutdown High contrast terminal designations and wiring diagram label make wiring easy Built-in short circuit protection from operator wiring errors Two DPOT Form-C relay contacts 24 VAC/DC or 120 VAC Compatible with existing System Sennsor duct smoke products, including remote accessories RTS151 and RTS151KEY Agency Listings LISTED APPROVED S911 3055518 3242-1653-0241 The DUCTSD 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). A plug-in sensor head offers simple installation and maintenance. The cover integrated smoke test port enables easy testing and maintenance. The housing provides ample wiring space, a 34-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations and a convenient wiring diagram label located on the inside of the power side housing cover make wiring easy. As many as 30 DUCTSD detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the tire source. An easy-access Test/Reset button and smoke test port makes it possible to test the unit with the cover on. The power board has an LED that can be used to indicate the status of the connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The DUCTSD smoke detector can be customized to meet local codes and specifications without additional wiring. The DUCTSD product line is compatible with previous System Sensor models, including remote test accessories RTS151 and RTS151KEY. WARNING: Duct smoke detectors are NOT a substitute for open area smoke detectors; NOT a substitute for early warning detection; NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information. DUCTSD Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor DUCTSD photoelectric duct smoke detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 30 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, cover integrated smoke test port or remote testing using the RTS151 or RTS151 KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Size: (Rectangular Dimensions) 14.38 in (37 cm) Length; 5 in (12.74 cm) Width; 2.5 in (6.36 cm) Depth (Square Dimensions) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 2.5 lbs (1.14 kg) Operating Temperature Range: -4° to 158°F (-20° to 70°C) Storage Temperature Range: -22° to 158°F (-30° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/mm (0.5 to 20.32 m/sec Electrical Ratings Power suøølv voltaae: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270 iF max. 270 pF max. N/A Reset voltage: 3.0 VDC mm. 2.0 VAC mm. 10 VAC mm. Reset time: (with RTS151) .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time: (by power down) 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 35 sec. max. 35 sec. max. 35 sec. max. Alarm response time: 15 sec. 15 sec. 15 sec. Sensitivity Test: See detector label See detector label See detector label Current Requirements: (Using No Accessories) Max. standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max. alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz Contact Ratings Alarm initiation contacts: (SPST) 2.OA @ 30 VDC (resistive) Alarm auxiliary contacts: 10A @ 30 VDC (resistive); 1 O @ 250 VAC (resistive); ½ HP @ 240 VAC ; ¼ HP @ 120 VAC (DPDT) Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory contacts: (SPDT) Accessory Current Loads at 24 2.OA @ 30 VDC (resistive); 2.OA @ 125 VAC (resistive) VDC Device Standby Trouble Alarm APA151 12.5 mA n/a 30 mA Max. MHR/MHW 0 mA n/a 29 mA Max. RA100Z 0 mA n/a 12 mA Max. RTS151/RTS15IKEY 0mA/12mA n/a 12mAMax. Note: Any combination of accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the DUCTSD Sampling Tube The DUCTSD sampling tube may be installed froni the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). ------------ I POWER INPUTS (NOTE 1) r4V -1 120 FM I I 910 I I OR I I AUXILIARY CONTACTS FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB I i9 87 I I SUPERVISORY CONTACTS (NOTE 3) I 14 ALARM S (,9 ALARM N.C. INITIATION CONTACTS (NOTE 4) ( ALARM C EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER -- —I 7 LAST DETECTOR IN THE LOOP NOTE 3: Supervisory contacts shown in standby position. Open contacts indicate a trouble condition to the panel. See specifications for contact ratings. NOTE 4: Alarm Initiation contacts shown in standby position. Closed contacts indicate an alarm condition to the panel. See specifications for contact ratings. I Wiring for 4-wire Duct Smoke Detector and Accessories ' I POWERINPUTS(NOTE1) I 4VAC/D 120 I IVACi I I I 910 I I OR I I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB "JN 1 GIN I SUPERVISORY CONTACTS I (NOTE 3) I SUPN.O. SUPC I UL/FMLTED 14 3 CONTROL PANEL ALARM o ALARM N.C. ALARM INITIATION INITIATION CONTACTS LOOP (NOTE 4) I 4 ALARM C I FIRST DETECTOR IN THE LOOP NOTE 1: 24V Power Inputs accept 24VDC of either polarity or 24VAC 50-601-1z. 120VAC Power Inputs accept only 120VAC I 50-60Hz. Connect power source to appropriate terminals of each detector. See specifications for additional power Supply information. NOTE 2: Auxiliary contacts shown in standby position. Contacts I switch during alarm as indicated by arrows. Auxiliary contacts are not to be used for connection to the control panel. See specifications for contact ratings. *please refer to the corresponding installation manual for accessory wiring diagrams. I Important Interconnect Notes I . When using the interconnect feature, all interconnected units must be powered using the same independent supply. Polarity must be maintained throughout the interconnect wiring. Connect the INT+ terminal on unit 1 to the INT+ terminal on unit 2 and so on. Similarly, connect the INT/AUX— terminal on unit 1. Up to 30 DUCTSD units may be interconnected. * NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. '!,' •-: r'\ I NAM I ?1 I •ro;:_.,::! I RTS151 UL S4011 RTS1 51 KEY UL S2522 APA151 UL S4011 RA100Z UL S2522 4 Jr-] MHW UL S4011 MHR UL S4011 Ordering Information I1lI[._ DUCTSD 4-wire photoelectric low-flow duct smoke detector Accessories I 2D51 4-wire conventional photoelectric sensor head M02-04-00 Test magnet DST1 Metal sampling tube duct width up to 1ff (0.3m) MHR Mini Horn, Red Mini Horn, White I DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft MHW (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 f P48-21-00 End cap for metal sampling tubes (0.6to1.2m) I DST5 Metal sampling tube duct widths 4 ft to 8 f RA1 OOZ Remote annunciator alarm LED (1.2 to 2.4 m) DST1 0 Metal sampling tube duct widths 8 ft to 12 ft RTS1 51 Remote test station (2.4t03.7m) I APA151 Remote annunciator with piezo alarm fRTS151 KEY Remote test station with key lock ETX Metal exhaust tube duct width 1 f (0.3m) 1 @2015 System Sensor. yç7J%7 3825 Ohio Avenue • St. Charles, IL 60174 SENSOR" Phone 800-SENSOR2 • Fax' 630-377-6495 www.systemsensor.com Product specifications subject to change without notice. Visit systemsenssr.com for current product information, including the latest version of this data sheet. HVDS84401 • 12/15 I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL IFIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1076:0195 Page 1 of 2 I CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 I Email: terrill.garland@kidde-fenwal.com DESIGN: Model Aries NetLink Fire Alarm Control Unit. Power limited. Local, releasing, auxiliary, automatic, manual, waterfiow and sprinkler supervisory services. Refer to listee's data sheet I for detailed product description and operational considerations. System components: 06-220270-001 MCB (Main Control Board)/UI (User Interface) I 76-800020-001 MCB (Main Control Board) 76-800020-002 UI (User Interface) 76-800030-003 PowerSupply/Charger 76-800030-004 PMU (Power Management Unit) I 76-800010-001 Expansion Backplane Module 76-800011-001 SLC (Signaling Line Circuit) Module 76-800012-001 Relay Module I 76-800013-001 NAC (Notification Appliance Circuit) ModuleIRNAC (Release Module) 76-800016-001 City-Tie Module 76-800020-003 LAM (LED Annunciator Module) 76-800000-004 Inline Releasing Device I 76-800400-001 Retrofit Enclosure Kit 76-800100-003 3-Tiered Expansion Enclosure 76-800200-003 2-Tiered Expansion Enclosure ' 76-800101-002 3-Tiered Canadian Application Enclosure with LAM 76-800201-002 2-Tiered Canadian Application Enclosure with LAM 76-800101-001 3-Tiered Canadian Application Enclosure without LAM 76-800201-001 2-Tiered Canadian Application Enclosure without LAM I 76-800101-005 3-Tiered Dead Front 76-800201-005 2-Tiered Dead Front *76..800014..001 *NIC (Expansion Card) I *76800015001 *DACT (Dialer Module) *76800017001 *1CM (Internet Communications Module) RATING: Primary: 120/240 VAC, Standby: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances I and in a manner acceptable to the authority having jurisdiction. *Rev 06-24-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other ' Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1076:0195 Page 2 of 2 MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a fire alarm control unit for use with listees separately listed electrically and functionally compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 06-24-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct IV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1076:0144 Page 1 of 2 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrill.garlandkidde-fenwal.com DESIGN: Control Unit Accessories. Refer to listee's data sheet for additional detailed system description and operational considerations. Models 70-407008-001 and 70-407018-001; normally-open contact input devices *Models 70-417008-001 and 70-417018-001; normally-open contact input devices *Module 70-417008-002; normally-closed contact input devices Models 70-407008-002 and 70-407018-002; normally-closed contact input devices Models 70-408004-001 and 70-408014-001; addressable relay output devices Model 30-472001-000; remote trouble indicating panel Model 74-200041-001; limiting resistor Models 74-200012-001, 74-200012-002 and 74-200012-004; loop isolators Models 89-100081-001 AIM (AnaLASER Interface Module) and 89-100083-001 IIM-2000 (Stand Alone) Models 70-200200-001 and 70-200200-003 ASM (Addressable Signal Sounder Module), 73-100001-003 AAM (Addressable AlarmLine Module), 73-100003-001 AAM; NEMA 4 Enclosure, Models 74-800300-001, *76..800300..001; RDCM's (Remote Display Control Modules) Models 74-800300-101 and *76..800300..101; RDM (Remote Display Modules) Enclosures Models 74-300004-032 and 76-200004-032 ATM-L; (Annunciator Driver Modules) Models 74-300005-032, and 76-200005-032 ATM-R; (Relay Driver Modules) Models 74-100017-001, 76-100010-001, 74-600000-014, and 74-600000-514; Battery Boxes. Models 74-600000-006, 74-600000-516 and 76-600000-006 Fiber-Optic Converter Cards (0CC) Models 06-220171-001 thru -007; Compensating Resistors. Models 70-600000-001 and 70-600000-002; Remote Releasing Modules Models 30-330002-001 and 84-330002-001; Addressable Manual Pull Stations. For indoor use with Model SGB-325 back box or outdoor use with SGB-32C back box. RATING: Electrical: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: *Listed as control unit accessories for use with listee's separately listed fire alarm control *Revision 10-17-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RvlG operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division LI Listing No. 7300-1076:0144 Page 2 of 2 units. Refer to listee's Installation Instruction Manual for details. *Revision 10-17-2018 dcc T' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 3242-1653:0241 Page 1 of 1 I CATEGORY: 3242 - DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 I Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models DUCTSD and DUCTSD240 conventional photoelectric duct smoke detector. The I units consist of a plastic enclosure, relay, electrical components, sampling and exhaust tubes and listed 2D51 detector head (CSFM Listing No. 7272-1653:203). Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: 120VAC, 24VAC, 20-29 VDC INSTALLATION: In accordance with printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector for use in ducts with air velocities I from 100 to 4000 fpm. Units are apporved for use with separately listed fire alarm control units. Units are not listed for open area protection. Refer to listee's Installation Instruction Manual for details. I I I I I I 10-22-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division