Loading...
HomeMy WebLinkAbout6030 AVENIDA ENCINAS; 220; FPC2018-0225; PermitEift Print Date: 10/24/2022 Permit No: FPC2018-0225 Job Address: 6030 AVENIDA ENCINAS, #220, CARLSBAD, CA 92011-1061 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: Track #: Applied: 07/25/2018 Valuation: $0.00 Lot #: Issued: Occupancy Group: Project #: Finaled Close Out: 12/11/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Wong, Cindy Plan Check #: Project Title: Description: (4) HEAD TI.: TOYOTA COLLISION CENTER FPContractor: COSCO FIRE PROTECTION INC 1075 W LAMBERT RD BREA, CA 92821-2944 (858) 444-2000 FEE AMOUNT FIRE NFPA 13 or 13R System 6 heads or less $121.00 Total Fees: $121.00 Total Payments To Date: $121.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov PIPE LEGEND SPRINKLER LEGEND (E) SSP SPRINKLER TO REMAIN NEW 1' PIPE TO (A)® (N) SSP SPRINKLER TO BE BE INSTALLED INSTALLED — — — EXISTING PIPE TO (E) PENDENT SPRINKLER TO REMAIN BE RELOCATED r IJ Cul 1t \ I — 1 W40 WNN-BEARM PAU. SYMBOL LEGEND I SPRINKLER HEAD LEGEND SYMBOL S/il ORIFICE NFT K-FACT. HEAD FINISH I PLATE I FINISH I I QUAN. I IKING MICROMATIC PENDENT SPRINKLER S.R. VK102 " ' 5.6 WHITE WHITE 155" 2 1 1802-0317 TOTAL SPRINKLERS = 2 I THIS PROJECT I ARM-OVER (SEE PLAN) NIPPLE EL 0—I 0 Lii Ui BRANCH LINE NO X /2 R.C. CEILING GENERAL NOTES ALL MATERIALS & INSTALLATION OF THIS AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE IN ACCORDANCE WITH N.F.P.A #13 (2016 EDITION), & THE CARLSBAD FIRE PREVENTION. NEW PIPING SHALL BE SCH.40 BLACK PIPE OR THREADABLE THINWALL WITH THREADED DUCTILE IRON FITTINGS. FIRE SPRINKLER SPACING SHALL BE LIGHT HAZARD (225 SQ. FT) MAX © LOCKER ROOM. - FIRE SPRINKLER'S SHOWN SHALL BE EXTENDED DOWN FROM THE EXISTING OVERHEAD FIRE SPRINKLER SYSTEM. HYDROSTATIC REQUIREMENTS FOR MODIFICATIONS TO A SYSTEM WITH 20 OR MORE HEADS &/OR WHERE MODIFICATIONS CANNOT BE ISOLATED, THE SYSTEM IS PERMITTED TO BE TESTED AT WORKING PRESSURE FOR 2 HOURS. SCOPE OF WORK 1. PROVIDE DESIGN, MATERIALS, LABOR AND TOOLS TO ADD / RELOCATE SPRINKLERS TO ACCOMMODATE THE NEW WALL LAYOUT. 13 C I D -A ------- %_ % A1.1 6'-U---- _j L__ n --------- j 71 NORTH FIRE SPRINKLER T.I. PIPING PLAN 1 y SCALE 3/16'=l'-O' ARM-OVER DETAIL NTS WOOD JOIST SWG WOOD PIPE SWG IAMMY SCREW SIZE I SIZE I' TO Y I SWG-20 TOLCO FIG. 100 I A.T.R. 3-1/2 TO 4 SWG-25 TOLCO FIG. 200 PIPE RING PIPE ARM-OVER DETAIL NIS MAXIMUM DISTANCE BETWEEN HANGERS NOMINAL PIPE SIZE (in.) 1" 1114" 11/2" 2" 3" 4" 6" 8" STEEL 12-0" 12-0" 15-0" 15-0" 15-0" 15-0" 15-0" 15-0" e- QShelI ' -- c 0~' JOB SITE EXISTING BELL I LOCATION 14-- 11"Y( EXISTING BACK FLOW LOCATION I VICINITY MAP ITCZ C, 2-o t8-0 2—T5 NORTH STEEL BAR JOIST .00 0000. cosco .. ••..., Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS California C-16 LIC. # 577621 SAN DIEGO OFFICE 4990 Greencraig Lane San Diego, California 92123 call 858) 444-2000.fox 858) 444-2056 www.coscofire.com SAN DIEGO. LOS ANGELO. FRESNO SAN FRANCISCO . SACRAMENTO. PORTLAND. SEame. ANCHORAGE TOYOTA COLLISION CENTER - FIRST FLOOR LOCKER ROOM 6030 AVENIDA ENCINAS, SUITE #240 CARLSBAD, CA. 92009 CONTRACT WITH: CARLSBAD TOYOTA LEXUS 6030 AVENIDA ENCINAS STE #220 / 240 ~wv CARLSBAD, CA. 92009 DRAWING TITLE: FIRE SPRINKLER T.I. PIPING PLAN DATE: 7/30/2018 SCALE: AS NOTED DRAWN BY: f.A. JOB NO. 1807-2238 SHEET NO.