HomeMy WebLinkAbout6060 AVENIDA ENCINAS; ; FPC2019-0123; PermitLIft Print Date: 10/24/2022 Permit No: FPC2019-0123 Job Address: 6060 AVENIDA ENCINAS, CARLSBAD, CA 92011-1053 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2110303100 Track #: Applied: 05/31/2019 Valuation: $30,000.00 Lot #: Issued: 01/16/2020 Occupancy Group: Project #: Finaled Close Out: 03/13/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Project Title: Description: IMPERIAL SPRINKLER SUPPLY -UPGRADE FIRE SPRINKLER SYSTEM (RISER REPLACEMENT) FPContractor: MARK STRECKER 4140 OCEANSIDE BLVD, # STE 159-542 OCEANSIDE, CA 92056-6005 (760) 594-0994 FEE AMOUNT FIRE Plan Review Per Hour - Office Hours $306.00 Total Fees: $306.00 Total Payments To Date: $306.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov - - - Fire Protection by Computer Design FIRE CODE INC. 63 VIA PICO PLAZA #107 SAN CLEMENTE, CA 92672 (949)369-1000 Job Name : 6060 avenida encinas Building Location System Contract Data File proof caic to src.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 FIRE CODE INC. Page 1 6060 avenida encinas Date 5/29/19 HYDRAULIC CALCULATIONS for Project name: 6060 avenida encinas Location: Drawing no: Date: 5/29/19 Design Remote area number: Remote area location: Occupancy classification: Density: .20 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler: 120 - SqFt Type of sprinklers calculated: No. of sprinklers calculated: 13 In-rack demand: - GPM Hose streams: 250 - GPM Total water required (including hose streams): 575.110 -GPM Type of system: Volume of dry or preaction system: - Gal Water supply information Date: 4/26/19 Location: 6060 AVENIDA ENCINAS Source: CARLSBAD FIRE DEPRTMENT Name of contractor: WEST COAST FIRE PROTECTION Address: 271 ROYMAR ROAD/ OCEANSIDE, CA 92058 / LIC #: C16-997208 Phone number: 760-754-8473 Name of designer: J B Authority having jurisdiction: CARLSBAD FIRE DEPRTMENT Notes: (Include peaking information or gridded systems here.) (SEE GRID PEAKING INFO PROVIDED) 59.961 -Psi Computer Programs by Hydratec Inc. Revision: 50.52.1 fl Water Curve C 0 • FIRE CODE INC. Page 2 6060 avenida encinas Date 5/29/19 City Water Supply: Demand: Cl - Static Pressure : 63.9 Dl - Elevation : 8.229 C2 - Residual Pressure: 12.9 D2 - System Flow : 325.11 C2 - Residual Flow : 3100 D2 - System Pressure : 59.961 Hose (Demand) : 250 D3 - System Demand : 575.11 Safety Margin : 1.679 150 140 130 p120 R° E10° s 90 s 8° u 7° cr D2 R 60 50 3 40 - 30 - 20 i11__ 10 . . 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings•d Summary S FIRE CODE INC. Page 3 6060 avenida encinas Date 5/29/19 Fitting Legend Abbrev. Name /2 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zih Wilkins 450 Fitting generates a Fixed Loss Based on Flow Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD FIRE CODE INC. Page 4 6060 avenida encinas Date 5/29/19 .Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1 19.0 27.61 na 2 20.0 5.6 19.56 na 24.77 0.15 120 7.0 3 20.0 5.6 18.51 na 24.09 0.2 120 7.0 4 20.0 5.6 18.37 na 24.0 0.2 120 7.0 5 20.0 5.6 18.49 na 24.08 0.2 120 7.0 6 20.0 5.6 19.48 na 24.72 0.2 120 7.0 8 19.0 27.75 na 9 20.0 5.6 19.66 na 24.83 0.2 120 7.0 10 20.0 5.6 18.6 na 24.15 0.2 120 7.0 11 20.0 5.6 18.46 na 24.06 0.2 120 7.0 12 20.0 5.6 18.58 na 24.14 0.2 120 7.0 13 20.0 5.6 19.58 na 24.78 0.2 120 7.0 15 19.0 28.25 na 16 20.0 5.6 23.44 na 27.11 0.2 120 7.0 17 20.0 5.6 23.4 na 27.09 0.2 120 7.0 18 20.0 5.6 23.75 na 27.29 0.2 120 7.0 20 19.0 29.05 na 22 19.0 32.74 na 24 19.0 29.7 na 26 19.0 30.17 na 28 19.0 30.49 na 30 19.0 30.66 na 32 19.0 30.71 na 7 19.0 30.14 na 14 19.0 30.27 na 19 19.0 30.76 na 21 19.0 31.67 na 23 19.0 32.74 na 25 19.0 33.82 na 19.0 35.14 na •27 29 19.0 36.75 na 33 19.0 40.56 na 31 19.0 40.61 na Ti 19.0 40.78 na TR 19.0 41.28 na BR 1.0 54.28 na Ui -3.0 56.11 na SRC 1.0 59.96 na 250.0 The maximum velocity is 15.09 and it occurs in the pipe between nodes 29 and Ti Computer Programs by Hydratec Inc. Revision: 50.52.1 S Final Calculations - Hazen-Williams - 2007 FIRE CODE INC. Page 5 6060 avenida encinas Date 5/29/19 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 -61.40 1.38 2T 12.0 15.920 27.606 to 120.0 0.0 12.000 -0.433 2 -61.4 -0.2727 0.0 27.920 -7.613 Vel = 13.17 2 24.76 1.38 0.0 10.000 19.560 K Factor 5.60 to 120.0 0.0 0.0 0.0 3 -36.64 -0.1048 0.0 10.000 -1.048 Vel = 7.86 3 24.10 1.38 0.0 10.000 18.512 K Factor = 5.60 to 120.0 0.0 0.0 0.0 4 -12.54 -0.0145 0.0 10.000 -0.145 Vel = 2.69 4 24.00 1.38 0.0 10.000 18.367 K Factor =5.60 to 120.0 0.0 0.0 0.0 5 11.46 0.0123 0.0 10.000 0.123 Vel = 2.46 5 24.08 1.38 0.0 10.000 18.490 K Factor =5.60 to 120.0 0.0 0.0 0.0 6 35.54 0.0991 0.0 10.000 0.991 Vel = 7.62 6 24.71 1.38 2T 12.0 26.830 19.481 K Factor = 5.60 to 120.0 0.0 12.000 0.433 7 60.25 0.2633 0.0 38.830 10.223 Vel = 12.92 0.0 60.25 30.137 KFactor= 10.98 *8 -61.58 1.38 2T 12.0 15.920 27.746 to 120.0 0.0 12.000 -0.433 9 -61.58 -0.2741 0.0 27.920 -7.653 Vel = 13.21 9 24.83 1.38 0.0 10.000 19.660 K Factor =5.60 to 120.0 0.0 0.0 0.0 10 -36.75 -0.1055 0.0 10.000 -1.055 Vel = 7.88 10 24.15 1.38 0.0 10.000 18.605 K Factor = 5.60 to 120.0 0.0 0.0 0.0 11 -12.6 -0.0145 0.0 10.000 -0.145 Vel = 2.70 11 24.06 1.38 0.0 10.000 18.460 K Factor =5.60 to 120.0 0.0 0.0 0.0 12 11.46 0.0122 0.0 10.000 0.122 Vel = 2.46 12 24.14 1.38 0.0 10.000 18.582 K Factor = 5.60 to 120.0 0.0 0.0 0.0 13 35.6 0.0994 0.0 10.000 0.994 Vel = 7.64 13 24.78 1.38 2T 12.0 26.830 19.576 K Factor =5.60 to 120.0 0.0 12.000 0.433 14 60.38 0.2643 0.0 38.830 10.263 Vel = 12.95 0.0 60.38 30.272 K Factor= 10.97 * 15 -33.99 1.38 2T 12.0 35.920 28.253 to 120.0 0.0 12.000 -0.433 16 -33.99 -0.0913 0.0 47.920 -4.376 Vel = 7.29 16 27.11 1.38 0.0 10.000 23.444 K Factor =5.60 to 120.0 0.0 0.0 0.0 17 -6.88 -0.0048 0.0 10.000 -0.048 Vel = 1.48 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams FIRE CODE INC. Page 6 6060 avenida encinas Date 5/29/19 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C',or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 17 27.09 1.38 0.0 10.000 23.396 K Factor = 5.60 to 120.0 0.0 0.0 0.0 18 20.21 0.0349 0.0 10.000 0.349 Vel = 4.34 18 27.29 1.38 2T 12.0 26.830 23.745 K Factor= 5.60 to 120.0 0.0 12.000 0.433 19 47.5 0.1695 0.0 38.830 6.583 Vel = 10.19 0.0 47.50 30.761 K Factor= 8.56 * 20 16.70 1.38 4T 24.0 82.750 29.049 to 120.0 0.0 24.000 0.0 21 16.7 0.0245 0.0 106.750 2.616 Vel = 3.58 0.0 16.70 31.665 K Factor= 2.97 22 0.0 1.38 4T 24.0 82.750 32.742 to 120.0 0.0 24.000 0.0 23 0.0 0.0 0.0 106.750 0.0 Vel = 0 0.0 0.0 32.742 K Factor =0 0 24 to 21.35 1.38 120.0 4T 24.0 0.0 82.750 24.000 29.696 0.0 25 21.35 0.0386 0.0 106.750 4.123 Vel = 4.58 0.0 21.35 33.819 K Factor= 3.67 26 23.61 1.38 4T 24.0 82.750 30.172 to 120.0 0.0 24.000 0.0 27 23.61 0.0465 0.0 106.750 4.965 Vel = 5.06 0.0 23.61 35.137 KFactor= 3.98 28 26.76 1.38 4T 24.0 82.750 30.488 to 120.0 0.0 24.000 0.0 29 26.76 0.0586 0.0 106.750 6.260 Vel = 5.74 0.0 26.76 36.748 K Factor= 4.41 30 34.37 1.38 4T 24.0 82.750 30.660 to 120.0 0.0 24.000 0.0 31 34.37 0.0932 0.0 106.750 9.951 Vel = 7.37 0.0 34.37 40.611 K Factor= 5.39 32 34.20 1.38 4T 24.0 82.750 30.708 to 120.0 0.0 24.000 0.0 33 34.2 0.0923 0.0 106.750 9.855 Vel = 7.34 0.0 34.20 40.563 K Factor= 5.37 . 1 61.40 2.635 0.0 12.000 27.606 to 120.0 0.0 0.0 0.0 8 61.4 0.0117 0.0 12.000 0.140 Vel = 3.61 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams FIRE CODE INC. Page 7 6060 avenida encinas Date 5/29/19 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 8 61.59 2.635 0.0 12.000 27.746 to 120.0 0.0 0.0 0.0 15 122.99 0.0422 0.0 12.000 0.507 Vel = 7.24 15 33.99 2.635 0.0 12.000 28.253 to 120.0 0.0 0.0 0.0 20 156.98 0.0663 0.0 12.000 0.796 Vel = 9.24 20 -16.70 2.635 0.0 12.000 29.049 to 120.0 0.0 0.0 0.0 24 140.28 0.0539 0.0 12.000 0.647 Vel = 8.25 24 -21.35 2.635 0.0 12.000 29.696 to 120.0 0.0 0.0 0.0 26 118.93 0.0397 0.0 12.000 0.476 Vel = 7.00 26 -23.60 2.635 0.0 12.000 30.172 to 120.0 0.0 0.0 0.0 28 95.33 0.0263 0.0 12.000 0.316 Vel = 5.61 28 -26.76 2.635 0.0 12.000 30.488 to 120.0 0.0 0.0 0.0 30 68.57 0.0143 0.0 12.000 0.172 Vel = 4.03 30 -34.37 2.635 0.0 12.000 30.660 to 120.0 0.0 0.0 0.0 32 34.2 0.0040 0.0 12.000 0.048 Vel = 2.01 S 0.0 34.20 30.708 K Factor= 6.17 ** 7 60.25 2.635 0.0 12.000 30.137 to 120.0 0.0 0.0 0.0 14 60.25 0.0113 0.0 12.000 0.135 Vel = 3.54 14 60.38 2.635 0.0 12.000 30.272 to 120.0 0.0 0.0 0.0 19 120.63 0.0408 0.0 12.000 0.489 Vel = 7.10 19 47.50 2.635 0.0 12.000 30.761 to 120.0 0.0 0.0 0.0 21 168.13 0.0753 0.0 12.000 0.904 Vel = 9.89 21 16.70 2.635 0.0 12.000 31.665 to 120.0 0.0 0.0 0.0 23 184.83 0.0898 0.0 12.000 1.077 Vel = 10.87 23 0.0 2.635 0.0 12.000 32.742 to 120.0 0.0 0.0 0.0 25 184.83 0.0898 0.0 12.000 1.077 Vel = 10.87 25 21.35 2.635 0.0 12.000 33.819 to 120.0 0.0 0.0 0.0 27 206.18 0.1098 0.0 12.000 1.318 Vel = 12.13 27 23.60 2.635 0.0 12.000 35.137 to 120.0 0.0 0.0 0.0 29 229.78 0.1342 0.0 12.000 1.611 Vel = 13.52 29 26.76 2.635 T 16.474 8.040 36.748 .to 120.0 0.0 16.474 0.0 Ti 256.54 0.1646 0.0 24.514 4.034 Vel = 15.09 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams FIRE CODE INC. Page 8 6060 avenida encinas Date 5/29/19 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 256.54 40.782 KFactor= 40.17 ** 33 34.20 2.635 0.0 12.000 40.563 to 120.0 0.0 0.0 0.0 31 34.2 0.0040 0.0 12.000 0.048 Vet = 2.01 31 34.37 2.635 0.0 12.000 40.611 to 120.0 0.0 0.0 0.0 Ti 68.57 0.0142 0.0 12.000 0.171 Vet = 4.03 0.0 68.57 40.782 K Factor= 10.74 * Ti 325.11 4.26 E 13.167 7.200 40.782 to 120.0 0.0 13.167 0.0 TR 325.11 0.0246 0.0 20.367 0.501 Vet = 7.32 TR 0.0 4.26 Fsp 0.0 21.160 41.283 to 120.0 3E 39.501 68.469 10.796 * Fixed Loss = 3 BR 325.11 0.0246 S 28.968 89.629 2.204 Vet = 7.32 BR 0.0 6.16 E 20.084 12.000 54.283 140.0 0.0 20.084 1.732 .to Ui 325.11 0.0031 0.0 32.084 0.099 Vet = 3.50 Ui 0.0 7.98 6E 143.552 520.000 56.114 to 140.0 G 5.317 241.912 3.185 *Fixed Loss 4918 SRC 325.11 0.0009 2T 93.043 761.912 0.662 Vet = 2.09 Zih 0.0 250.00 Qa = 250.00 575.11 59.961 KFactor= 74.27 Computer Programs by Hydratec Inc. Revision: 50.52.1 Worldwide S tqC00 Contacts www.tyco-fire.com Series TYL — 56 and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage S General Description The TYCO Series TY-L 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprin- klers described herein are stan- dard response, standard coverage, solder type spray sprinklers. They are designed for use in light, ordinary, and extra-hazard commercial occupan- cies such as banks, hotels, shopping malls, factories, refineries, and chemi- cal plants. The Series TY-L Recessed Pendent Sprinkler, where applicable, is intended for use in areas with a fin- ished ceiling. It uses a two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/4 in. (6,4 mm) of recessed adjust- ment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed to corrosive atmospheres. Although cor- rosion-resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all pos- sible corrosive atmospheres. Conse- IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 quently, it is recommended that the end-user be consulted about the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-L Pendent Sprinkler can be obtained by utilizing the Series TY-L Pendent Sprinkler in combination with the Model S Shield. NOTICE The Series TY-L 5.6 and 8.0 K-fac- tor Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. NFPA 13 prohibits installation of 1/2 inch NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. AUGUST 2018 Sprinkler Identification Number (SIN) TY3111 ... Upright 5.61K, 1/2 in. NPT TY3211 . . .Pendent 5.61K, 1/2 in. NPT TY4111 ... Upright 8.01K, 3/4 in. NPT TY4211 . . .Pendent 8.01K, 3/4 in. NPT TY4811 ... Upright 8.0K, 1/2 in. NPT TY4911 . . .Pendent 8.01K, 1/2 in. NPT TY3111 is a re-designation for S1800 and G3111 TY3211 is a re-designation for S1801 and G3112 1Y4111 is a re-designation for S1810 and G3101 TY4211 is a re-designation for S1811 and G3102 TY481 is a re-designation for S1805 TY4911 is a re-designation for S1806 TFPIIO S I 2-5/8 (66,7 mm) 7/16 (11,1 mm) NOMINAL MAKE-IN /\ / 1/2 NPT** I WRENCH FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 1 SERIES TY-L UPRIGHT (TY31II) AND PENDENT (TY3211) SPRINKLERS, 5.6 K-FACTOR, 1/2 IN. NPT * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING 1 - Frame 3 - Ejection 5 - Strut 2 - Sealing Spring 6 - Hook Button 4 - Fusible 7 - Deflector* Element WRE L NCH AREA 166,7 mm) STYLE 20 ) (50,8 mm) RECESSED ESCUTCHEON 2-7/8'(73,0 mm) DIA. 7* L SURFACE 2-5/8" S TFPIIO Page 2 of 6 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector, special request. PLATE SEATING SURFACE 1 - Frame 3 - Ejection 5 - Strut 2 - Sealing Spring 6 - Hook Button 4 - Fusible 7 - Deflector* Element WRENCH AREA (68,3 mm) 3 \ I L 2" STYLE 30 (50,8 mm) RECESSED ESCUTCHEON 3/4" NPT** WRENCH 2-7/8" (73,0 mm) DIA. FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TY-L UPRIGHT (TY4III) AND PENDENT (TY4211) SPRINKLERS, 8.0 K-FACTOR, 3/4 IN. NPT S F2-5/8" (66,7 mm),, 7/16" (11,1 mm) I I NOMINAL I I MAKE-IN I 1/2" NPT** f WRENCH FLANGES 1 - Frame 3 - Ejection 5 - Strut 2 - Sealing Spring 6 - Hook Button 4 - Fusible 7 - Deflector" Element WRENCH AREA F) 166, mm) STYLE 20 5 (50,8 mm) (qp L 2 RECESSED TCHEON -7/8" (73,0 mm) DIA. * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING SURFACE I . / 2-5/8' UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 3 SERIES TY-L UPRIGHT (TY4811) AND PENDENT (TV4911) SPRINKLERS, 8.0 K-FACTOR, 112 IN. NPT S fl TFPI 10 Page 3 of 6 Frame Sprinkler Finish K Type Temp. Rating Color Natural I Chrome Lead Wax I Wax Over Code Brass Plated Coated Coated Lead Coated Pendent (TY3211) 165°F (74°C) Unpainted 1, 2, 3 212°F (100°C) White and 1, 2, 3, 5 5.6 1/2 in. Upright (TY3111) 280°F (138°C) Blue 1,2 4 j N/A NPT Recessed Pendent 165°F (74°C) Unpainted 1, 2, 3, 5 N/A6 212°F (100°C) White 1, 2, 3, 5 (TY3211 w/Style 20) 165°F (74°C) Unpainted 1,2,3 212°F (100°C) White Pendent (TY4211) 1, 2, 3 280°F (138°C) Blue 1,2 J N/A 8.0 165°F (74°C) Unpainted 3/4 in. 1,2,3 212°F (100°C) White NPT Upright (TY4111) 1, 2, 3, 5 280°F (138°C) Blue 1,2 4 N/A Recessed Pendent 165°F (74°C) Unpainted 1,2,5 N/A 212°F (100°C) White (TY4211 w/Style 30) Pendent (TY4911) 165°F (74°C) Unpainted 1, 2, 3 212°F (100°C) White and 1, 2, 3, 5 8.0 1/2 in. Upright (TY4811) 280°F (138°C) Blue 1,2 N/A NPT Recessed Pendent 165°F (74°C) Unpainted 1,2 N/A 212°F (100°C) White (TY4911 w/Style 20) NOTES: UL Listed 4. FM Approved for maximum 150°F (68'C) ambient temperatures C-UL Listed 5. LPCB Approved (LPCB Ref. No. 094a/03) FM Approved 6. Not Available (N/A) TABLE A LABORATORY LISTINGS AND APPROVALS Technical Data Approvals UL and C-UL Listed FM and LPCB Approved Refer to Table A for complete approval infor- mation including corrosion resistant status. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=5.6 GPM/p5i½ (80,6 LPM/bar") K=8.0 GPM/psi/2 (115,2 LPM/bar") Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame .............................Brass Sealing Button ...........Bronze w/TEFLON Ejection Spring ..............Stainless Steel Strut ............................MONEL Hook .....................Bronze/MONEL Deflector ..........................Bronze Fusible Element .............Solder, Copper, Stainless Steel Operation A copper tube sealed by two stainless steel balls holds a fusible alloy. When the rated temperature is reached, the alloy melts and the balls are forced toward each other. This releases the tension mechanism and allows the sprinkler to operate. Design Criteria The TYCO Series TY-L 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as the UL Listing based on the requirements of NFPA 13 and FM Approval based on the require- ments of FM Loss Prevention Data Sheets. Use only the Style 20 or 30 Recessed Escutcheon, as applicable, for recessed pendent installations. WRENCH RECESS ,Z;< FIGURE 8 W-TYPE 10 RECESSED SPRINKLER WRENCH TFPIIO Page 4 of 6 7/16*1/8 2-7/8 DIA. 1/2(12,7mm) (11,1*3,2 mm) I (73,0 mm) 1/4' (6,4 mm) I FACE OF 2-1/4' DIA. MOUNTING SPRINKLER (57,2 mm) PLATE FITTING qz t___ (3,2mm) I j1 t I 1 1-3/4(44,5mm) (38,1 mm) if 7/16±1/8" 2-7/8" DIA. 1/2(12,7mm) (11,1±3,2 mm) (73,0 mm) 1/4(6,4mm) FACE OF 2-1/4" DIA. MOUNTING SPRINKLER [ (57,2 mm) 1 PLATE FITTING MOUNTING SURFACE CLOSURE TY-L FIGURE 4 SERIES TY-L (TY3211) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT T-7- MOUNTING SURFACE .1 1-3/4(44,5mm) 1-1/2" (38,1 mm) CLOSURE TY-L FIGURE 5 SERIES TY-L (TY4211) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT 7/16±1/8" (11,1±3,2 mm) FACE OF SPRINKLER FITTING T-7- - MOUNTING SURFACE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) 1/2(12,7mm) 1/4(6,4mm) MOUNTING PLATE rLI(3,,2mm) I 1-3/4(44,5mm) 1-1/2" (38,1 mm) CLOSURE TY-L FIGURE 6 SERIES TY-L (TY4911) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 8.0 K-FACTOR, 1/2 IN. NPT 0 TFPIIO Page 5 of 6 L] Installation The TYCO Series TY-L 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions A leak tight 1/2 in. NPT sprinkler joint should be obtained with a torque of 7 to 14 ft-lb (9,5 to 19,0 Nm). A leak- tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 ft-lb (13,4 to 26,8 Nm). Higher levels of torque may distort the sprin- kler inlet and cause leakage or impair- ment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-L Upright and Pendent Sprinklers Installation The Series TY-L Pendent and Upright Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 7). For wax coated sprinklers, use an 8 or 10 in. adjustable Crescent wrench. With reference to Figures 1, 2, and 3, apply the W-Type 9 Sprinkler Wrench to the wrench area, or as applicable, apply the adjustable Crescent wrench to the wrenching flanges. Wax Coated Sprinklers When installing wax-coated sprinklers with the adjustable Crescent wrench, take care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment: Open the jaws of the wrench suffi- ciently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprin- kler, adjust the jaws of the wrench to just contact the sprinkler flats. After wrench tightening the sprin- kler, loosen the wrench jaws before removing the wrench. After Installation After installation, complete the following: Inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating whenever the coat- ing has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 inch diameter steel rod to the damaged areas of the wax, to smooth it back over areas where bare metal is exposed. IA'L•1tLII Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point it can begin to melt the wax, and appropriate precautions need to be taken when handling the heated rod to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick, the end of which is color coded. Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previ- ously described, touch the rod to the area requiring additional wax with the rod angled downward, and then touch the wax stick to the rod approximately 1/2 in. (12,7 mm) away from the area requiring retouching. The wax will melt and run down onto the sprinkler. Series TY-L Recessed Pendent Sprinklers Installation The Series TY-L Recessed Pendent Sprinkler must be installed in accor- dance with the following instructions: Step 1. After installing the Style 20 or 30 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 10 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 1, 2, or 3, apply the W-Type 10 Recessed Sprinkler Wrench to the sprinkler wrenching flanges. Step 3. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 or 30 Closure over the Series TY-L Recessed Pendent Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-L 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over-heated sprinklers must be replaced. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion-resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made so as to better determine the exact sprinkler condition and the long- term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TFPIIO Page 6 of 6 SI P/N 53 — XXX — X — XXX IN SPRINKLER I TEMPERATURE S FINISH I RATING 111 5.6K UPRIGHT (1/2 in. NPT) TY3111 1 6 7 8 L 9 NATURAL BRASS WAX COATED 165°F TO 280°F ONLY LEAD COATED WAX OVER LEAD 165°F TO 212°F ONLY CHROME PLATED 165 165°F (74°C) 212 212-F (100-C) 280 280°F (138°C) 112 5.6K PENDENT (1/2 in. NPT) TY3211 101 8.0K UPRIGHT (3/4 in. NPT) TY4111 102 8.0K PENDENT (3/4 in. NPT) TY4211 106 8.0K UPRIGHT (1/2 in. NPT) TY4811 107 8.0K PENDENT (1/2 in. NPT) TY4911 TABLE B SERIES TY-L PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION fl Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-L (specify SIN), (specify K-factor), (specify Upright, Pendent, or Recessed Pendent) Sprin- kler, Standard Response, Standard Coverage, (specify) temperature rating, (specify) finish or coating, P/N (specify from Table B) Recessed Escutcheon Specify: Style (specify) Recessed Escutcheon, (specify material) with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849 Specify: W-Type 10 Sprinkler Wrench, P/N 56-000-1-948 Wax Sticks (for retouching wrench- damaged wax coating) Specify: Series TY-L Sprinklers, (specify color), color coded Wax Stick for retouching, (specify) temperature rated, P/N (specify): Red for 165°F (74°C) .......P/N 56-065-1-155 Blue for 212°F (100°C) and 280°F (138°C) .........P/N 56-065-1-286 Note: Each wax stick is suitable for retouching up to twenty-five sprin- klers. The wax used for 280°F (138°C) sprinklers is the same as for 212°F (100°C) sprinklers. Therefore, the 280°F (138°C) sprinkler is limited to the same maximum ceiling temperature as the 212°F (100°C) sprinkler, which is 150°F (65°C). 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 C 201N Johnson Controls. All rights reserved. All spociticotions and other intorelation shown were current ocot doco,,lent revision date and are subject to change without notice. Johnson 0810 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA -,gisterod trademarks of National Rra Protection Association; MONELis a rsgpstsrnd trademark of Special Metals Corporetion; Controls TEFLON iso regpsrerod Sodomark of DuPont sum ZURN [©kD WILKINS Double Check Detector Assembly Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and backpressure of pol- luted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. Standards Compliance (Unless otherwise noted, applies to sizes 4" thru 10) ASSE® Listed 1048 CSA® Certified (4" & 6) AWWA Compliant C 510, and C550 UL® Classified C-UL® Classified FM® Approved NYC MEA 26-00-M VOL 3 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California NSF® Listed-Standard 61, Annex G* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM, NSF Listed Springs Stainless steel, 300 series Features Sizes: 4, 6" , 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI 1316.1 Class 125 Dimensions & Weights (do not include pkg.) WEIGHT _______ MODEL LESS OS&Y OS&Y WITH WITH SHUTOFF GATE GATE BFLY BFLY SIZE VALVES (GXF) (GXG) (GXF) (GXG) in. I mm lbs. I kg lbs. I kg lbs. I kg lbs. I kg lbs. kg 4 100 105 48 295 134 271 123 1751 79 153 69 6 1501 1741 79 474 215 452 205 276 126 248 112 8 200 402 1 182 878 398 824 374 1 592 1 269 1546 248 10 250 1420 1 191 1076 488 1018 462 1694 1315 1631 288 Options (Suffixes can be combined) El - with OS & Y gate valves (standard) L - less shut-off valves (grooved body connections) LM - less water meter - with remote reading meter El - with gpm meter (standard) fl - with cu ft/min meter E] G - with groove end gate valves FG - with flanged inlet gate connection and grooved outlet gate connection FS - with cast iron wye type strainer (flanged only) Eli FSC - with epoxy coated Wye type strainer (flanged only) E BG - with grooved end butterfly valves with integral supervisory switches BF - with flanged end butterfly valves with integral supervisory switches P1 - with Post Indicator Gate Valve Accessories E Repair kit (rubber only) E] Thermal expansion tank (Model XT) Valve setter (Model FLS or MJS or MJFS) E] Gate valve tamper switch (OSY-40) Flange by groove adapter (FLA) QT-SET Quick Test Fitting Set DIMENSIONS (approximate) MODEL B B B C C C 450DA A WITH GATE WITH BFLY LESS GATE OS&Y OS&Y WITH BFLY D SIZE VALVES VALVES VALVES OPEN CLOSED VALVES in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm 4 100 185/16 465 30 762 273/4 705 21 533 22314 578 181/4 460 9 229 8 203 6 150 1811/16 475 351/2 902 32 1/8 816 25 635 301/8 765 233/4 603 101/4 260 10 254 8 200 29 737 46 1168 429/16 1081 347/16 845 373/4 959 291/4 743 12 305 13 330 10 250 29 737 471/2 1207 47112 1207 347/16 845 453/4 1162 353/8 899 13 330 13 330 Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. C Date: 7/15 Document No. BF-450DA Product No. Model 450DA Page 1 of 2 3000 WILKtNl SETTE OUTDOOR INSTALLATION 0 400 800 1200 FLOW RATES (GPM) MODEL 450DA 8" & 10" (STANDARD & METRIC) FLOW RATES (Ifs) 0.0 63.1 126.2 189.3 15 U) 0. 10 0 -a .- --- -- - Flow Characteristics 0.0 ( 15 U) 0. (I) U, 10 0 —J w 5 IL 0 U) U) U) 0. 0 1000 2000 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the as- sembly shall be mounted above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 P.- V s- . - -- - 0 Rated Flow (established by approval agencies) 100.9 103 0. (I) 69 Lu 34 (n W of 0 °- 1600 252.4 El 103k JU) 69 Lu 34 U) w 0°- 4000 DIMENSIONS approximate) Al SETTER Al SETTER MODEL SIZE END TO END TOEND END FLS MJS in. mm in. I mm I in. mm 4 100 31 5/16 795 29.313 I 745 6 150 343/4 884 32.75 I 832 8 200 47 1194 44.625 11133 10 250 51 1295 47 11194 MODEL 450DA 4" & 6" (STANDARD & METRIC) FLOW RATES (Ifs) 25.2 50.5 75.7 Specifications The Double Check Detector Backflow Preventer shall be ASSE® Listed 1048 and supplied with full port OS & Y gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elasto- mers shall be EPDM. The checks shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Preventer shall be a ZURN WILKINS Model 450DA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 No. 182 S CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Imperial Sprinkler Supply SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 6060 Avenida Encinas CITY: Carlsbad PHONE: (760) 809-7987 FAX NUMBER: Largest Building (ft.2): 14,000 Sprinkled? Yes Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Avenida Encinas south of Palomar Airport Road TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 71 PSI Hydrant Number (if applicable):H61856 Elevation of test: 52 Feet Main Size: 12 INCH Pressure Zone: 215 Feet Date/Time of Test: Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 3,100 GPM Residual Pressure 20 PSI Atpeakdemand, this water system is capable of providing a fire flow discharge at 20 psi of 3,100 gpm. No specific fire Flow was pro vided for testing. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature:________________________________________ Title/Org:4_ctMaer Date: 04/24/2019 S S . . .•. J /3 100 U3 101, JI I _J 10" LU \O O \ \ \\ \ \ -13 Fire Flow Test Location H61856 \\\\ \\\ 0 \ \\\\\\\ \ \\ S U3 \ \ Project Site \\ \\\ \\\\\\\\\\ \ ± Legend Pipe \ \ \ \\ \\ZONE -241 #182 6060 Avenida Encinas -Fire Flow Analysis