HomeMy WebLinkAbout5823 NEWTON DR; ; AS130210; PermitCity of Carlsbad Sprinkler Permit Permit No: AS 130210 Job Address: 5823 NEWTON DR Permit Type: SPRINK Parcel No: 2120504300 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 11/26/2013 Approved: 12/13/2013 Issued: 1.2/13/2013 Inspector: Project Title: LIFE TECHNOLOGIES, NEWTON LAB TI: ADD SPINKLERS TO ACCOMMODATE NEW WALLS AND DROP CEILINGS, COSCO'S POINT OF CONNECTION IS AT EXISTING OVERHEAD ESFR SYSTEM. -REMOVE (E) ESFR SPRINKLER HEADS AND REPLACE WITH (N) SSP SPRINKLER HEADS Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: LIFE TECHNOLOGIES CORP 5791 VAN ALLEN WAY CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 268 0 268 0 I cosco ,*00000 '..• I Fire Protection San Diego Branch Office 10695 Treena SL, Suite 105 San Diego, CA 92131 (858) 444-2000 fax: 444-2056 CA License: C-16 #577621 www.coscofire.com MATERIAL SUBMITTAL Date: 11/12/13 Life Technologies Newton Lab 5823 Newton Dr. Carlsbad, CA 92008 JOB # 10.CA_5232 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. 'W Submitted by: L. Gonzalez AS130210 Los Angeles • San Francisco • Orange 0 Fresno • San Diego • Seattle August 13, 2009 Sprinkler 54a MIRAGE® STANDARD AND QR CONCEALED PENDENT 44J IF(IF*tt1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcscvikingcorp.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installa- tion on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to 1/2' (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPC Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2032 and 0786-CPD-40249 S Refer to the Approval Chart on page 54c and Design Criteria on page 54d for cULus Listing requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. ______________________________________ Minimum Operating Pressure: 7 psi (0.5 bar)* Viking Technical Data may be found on Maximum Working Pressure: Sprinkler VK463 is rated for use with water The Viking Corporation's Web site at working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) http:/Iwww.vikinggroupinc.com. sprinklers can be identified by locating "250" stamped on the deflec- The Web site may include a more recent tor. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. edition of this Technical Data Page. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65 °F (-55 "C) Patents Pending "cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Replaces page 54a-e, dated June 5, 2009. (Revised minimum and maximum dimensions in Figure 4). Sprinkler 54b August 13, 2009 MIRAGE® STANDARD AND QR CONCEALED PENDENT S.j IF(IF..1 SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A, 14697A, or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 155"/68" = B, 175°/79" = D, 200"/93° = E For example, sprinkler VK463 with a 155 "F/68 "C temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/SW1004, Painted Ivory = M-/5W1634, Painted Black = M-/SW1007 Temperature Suffix (°F/°C): 135°/57° UL (1390/590 FM) = A, 165"/74° = C For example, cover 13504 with a Polished Chrome finish and a 165 "F/74 °C temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135 "F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: . Refer to Table l Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) "Requires a /2" ratchet (not available from Viking). """Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731 A, Capacity: five (5) sprinklers (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. S EJ August 13, 2009 Sprinkler 54c MIRAGE® STANDARD AND QR CONCEALED PENDENT "p44.1 I F(AIF1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Sprinkler ' NPT ' Nominal ' Maximum Listings and Approvals4 Base SIN Thread Size K-Factor Water Working (Refer also to Design Criteria on page 54d.) Part No.' Inch mm U.S. Imet1ic2 Pressure cULus' FM NYC6 VdS LPCB I CE Standard Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) -- AU1, BXI -- AY1, CZ1 - -- 14697A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) -- - -- - AV2, BW2 AV2, BW27 Quick Response Applications 13503A VK462 1/2" 15 80.6 175 psi (12 bar) AV1, BXI -- AV1, BW1 - - AY2, CZ28 14697A VK462 1/2" 15 L5.6 80.6 175 psi (12 bar) AV1, BXI -- VK463 1/2" 15 80.6 AV1, BW1 13667A 250 psi (17.2 bar)3 AV1, BX1 -- AV1, BW1 -- -- -- Cover Plate Assembly Temperature Ratings9 U - 135°F (57 °C) cULus Listed cover 135041, 136421 (large diameter), Cover Plate Assembly Finishes10 Sprinkler Temperature Ratings or 153941 (square cover plate) FM Approved as 139 °F (59 °C) 1 - Polished Chrome, Brushed Chrome, V - 135 °F (57 °C) cULus Listed cover 135041 or 136421 (large diameter) Bright Brass, Antique Brass, A- 155 F (68 C) W- 165°F (74 °C) cover 135041 or 136421 (large diameter) Brushed Brass, Brushed Copper, B - 175°F (79°C) and 200°F (93 °C) X - 165 °F (74 °C) cover 135041, 136421 (large diameter), or 153941 Painted White, Painted Ivory, or C - 200 F (93 C) (square cover plate) Painted Black Y - 135 °F (57 °C) cover 135041 2 - Polished Chrome, Painted White Z - 165 °F (74 °C) cover 135041 Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for an additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. ((Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 8 (( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. The 135/139 °F cover has an orange label. The 165 °F cover has a white label. "Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155 °F(68°C) 100°F(38°C) 135 F(57C)cULus Red Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) 165 °F (74 °C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinkler 54d August 13, 2009 MIRAGE® STANDARD AND QR CONCEALED PENDENT '#44 II(lI'1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com cULus Listing Requirements: Mirage® Standard and Quick Response Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. FM AoDroval Requirements: Mirage® Concealed Pendent Sprinkler VK462 is FM Approved as a standard response standard spray sprinkler as indicated in the Approval Chart for hazard occupancies up to and including Ordinary Hazard, Group II. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8NJ) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 or QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordi- nances, and standards, whenever applicable. S C U S (0) \ NIKINGi Identification of Custom Paint Color: All custom color painted cover plates will have an identifying label af'f'ixed to the inside of the cover that indicates custom color and will have a representative sample (a paint dot) of the paint on the label, Figure 1: Identification of Custom Paint Color for Concealed Covers DU NOT PAINT (84.1 mm) Figure 2: Square Cover Assembly 15394 Sprinkler Frame Arms Sprinkler Wrench Flat NEVER install the sprinkler by applying the installation wrench across the frame arms. August 13, 2009 Sprinkler 54e MIRAGE® STANDARD AND QR CONCEALED PENDENT N4 II(I Is1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com 2-1/4' (57.2 mm) diameter opening Is required in the ceiling, bly ap Dr se E*) Sprinkler Wrench (Part No. 4047W/B)K* is shown) A 1/2' ratchet s required (not ilable from Viking) Step 2: Carefully press the Step 1: Carefully slide the wrench upward and turn slightly wrench sideways around to ensure engagement with the the deflector and pins, sprinkler wrench flats. 110 NOT overtighten. Use only the designated sprinkler wrench, Viking Part Number 14047V/B or 14031 110 NOT apply more than 25 ft tbs. of -torquie. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. IIJ Figure 3: Sprinkler Installation and Correct Use of Wrenches c i 1/2" (15 mm) NPT A 2-9/16" 2-1/16" mm I r Minimum _ U1[11 inn 2-3/4" (70 mm) or 3-5/16" (84,1 mm) Note: Upon sprinkler activation, the deflector descends to approximately 13/16" (20.6 rim) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation October 25, 2010 Sprinkler 105a QUICK RESPONSE 'II FJ F1G l.l:llE'7M DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suit- able for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and tem- perature ratings to meet design requirements. The special Polyester coating has been investigated for installation in corrosive atmospheres and is cULus listed as corrosion resistant as indicated in Approval Chart 1. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) NOTE: When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart I and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Viking Technical Data may be found on Specifications: The Viking Corporation's Web site at Minimum Operating Pressure: 7 psi (0.5 bar) http:I/www.vikinggroupinc.com. Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to The Web site may include a more recent 100 psi (6.89 bar) edition of this Technical Data Page. Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C3 1600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 Form No. F_031793 Replaces page 105a-f, dated August 12, 2010. (Revised sprinkler materials.) ,D~ VIKING o7297O Figure 1: Standard Sprinkler Wrench 07297W/B Figure 2: Wrench 07565W/13 for Adjustable Recessed Dry Pendent Sprinklers Sprinkler Wrench l7565V//B* must be used for installing recessed dry sprinklers Step 2 Carefully press the wrench upward and turn slightly to ensur engagement with the sprinkler wrench flats. NEXA 1/2' ratchet is .. required (Not avail- able from Viking.) Step 1 slide tl sideways cnrinklpr S Sprinkler 105b October 25, 2010 4I I FJ I4r1Eu l :II[s1U.7M QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ('A" dimension) to sprinkler base part number. Order in a specific length noted as the 'A" dimension. The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) for the adjustable standard style, 3" to 47(76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made-to-order" basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm). Adjustable Standard Dry Pendent up to 63-1/2" (1,613 mm). Plain Barrel Dry Pendent up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome-Enloy' = F, and White Polyester = M-AN Temperature Suffix (°F/°C): 155°/68° = B, 175°/79° = D, 200"/93° = E, 286"/141° = 3 For example, sprinkler VK176 with a Chrome finish and a 155 °F/68 "C temperature rating, and "A" length of 10" = Part No. 08383UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 07297W/B (available since 1991) Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) **A %" ratchet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954). Replacement Escutcheons: Adjustable Standard Dry Escutcheon: Base Part No. 07741 Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the are. INSPECTIONS, TESTS & MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Quick Response Dry Pendent Sprink- ler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor 5 or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. S October 25, 2010 Sprinkler 105c 41KJING* 1111M QUICK RESPONSE :DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs®vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155 °F (68 "C) 100 °F (38 "C) Red Intermediate 175 "F (79 "C) 150 "F (65 "C) Yellow Intermediate 200 °F (93 "C) 150 °F (65 "C) Green High 286 °F (141 "C) 225 "F (107 "C) Blue Sprinkler Finishes: Brass, Chrome-Enloy5 (patents pending), and White Polyester Corrosion-Resistant Coating3'4: White Polyester in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant Polyester coating has passed the standard corrosion test required by the approving agencies indicated in Approval Chart 1. These tests cannot and do not represent all possible corrosive environments. Note: This coating is NOT corrosion proof. Prior to installation, verify through the end-user that the coating is compatible with or suitable for the proposed environment. Polyester coating is applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. "When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. For 'A' Dimension: 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2" (12.7 mm) between 1-1/2' and 45-1/2' (38.1 mm and 1,156 mm). NOTE' The deflector- will be located approximately 3-7/16" (873 mm) below the ceiling with 1" (25,4 mm) upward and 1' (25.4 mm) downward adjustment. Deflector at minimum distance below ceiling NOTE To locate the deflector at the minimum distance _ below the ceiling, with no downward adjustment Minimum ceiling opening avojloble, order the f7/ diameter: 1-3/4" (44.5 mm), (61,9 mm) dry pendent sprinkler Maximum ceiling opening Minimum i" (25.4 mm) shorter tf - diameter: 2-1/4" (57 mm). than the 'A" dimension. / 13/16' _____________ NOTE: Finished L. (20.6 mm) To locate the deflector Ceiling at the maximum distance 4-7/16' below the cei(ing, with 1-1/2'----- Sleeve finish (112.7 mm) no downward adjustment (38.1 mm) matches escutcheon. Maximum available, order the diameter J __ dry pendent sprinkler 3-1/16' 1" (25.4 mm) longer (77.8 mm) than the 'A" dimension, Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler Sprinkler 105d October 25, 2010 41KJNG* QUICK RESPONSE :DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Sprinkler Thread Size Nominal K-Factor2 Order Length Increment Listings and Approvals4 (Refer also toP!L9n Crit!!1bei92 - ______ ________ ___________ SIN Style U.S. metric3 Inches ________ mm cULus' NYC6 VdS LPCB CE Base Part No." NPT BSP 08383U VK176 Adjustable 1° -- 5.6 80.6 1/2" 12.7 Al Al -- -- -- -- -- 80.6 1/2' 12.7 Al -- -- -- -- -- 25 mm 16457U Standard -- 08385U VK180 Adjustable 1" -- 5.6 80.6 1/4" 6.35 B2 B2 -- -- -- -- 25 mm -- 80.6 1/4" 6.35 B2 -- -- -- -- -- 16453U Recessed -- 08387U Plain 1" -- 5.6 80.6 1/2" 12.7 A3 -- -- -- -- VK172 16455U Barrel -- 125 mm -- 80.6 1/2" 12.7 A3 _~A4_t -- -- -- -- -- Approved Temperature Ratings Approved Finishes and "A" Dimensions A - 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), - Chrome-EnloyO or White Polyester7 sprinkler with a Chrome-EnloyO or White Polyester Sleeve and 286 °F (141 °C) and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) "A" 2 - Chrome-Enloy or White Polyester7 with dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F Chrome-Enloy, Brass, or White Polyester7 with "A" dimensions 3" to 47(76.2 mm to 1,194 mm) (93 °C) 4- Chrome-Enloy® or Brass with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. cULus Listed as corrosion resistant. I NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRYI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. 0 4: Adjustable Recessed Dry Pendent Sprinkler FTI For 'A' Dimension Determine the bistaruce from face of tee to the Finished ceiling. Round to nearest 1/4' (6,35 mm) between 3-1/4' (82.5 rim) anol 47-1/2' (1,207 mm). TE' Sprinkler wfll be recessed approximateLy 5/16' (7.9 mm) above the finished ceiling with 5/8' (15.8 mm) vertical adjustment available, ished ceiling Minimum Ceiling 2-118' (54 mm) Maximum ceilim 2-1/2' (63.5 mu . Adjustment 5/16° (7.9 mu 5/16° (7,9 mu Minimum' 1' (25.4 mm) Maximum 1-5/8° (42,1 r October 25, 2010 Sprinkler lOSe QUICK RESPONSE N41KJNG4 l.l:IIEu'7M :DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com nkler Base SIN Style I 0 Thread Size Nominal K-Factor2 'Order Length Increment' FM Approvals4 116453U U.S. metric3 Inches mm (Refer also to Design Criteria below.) 08383U .5.6 art No.1 N 11Z5.6 VK176 Adjustable Standard 80.6 1/2' 12.7 Al 16457U --80.6 1/2" 12.7 Al 08385U VK180 Adjustable Recessed 5.6 80.6 1/4" 6.35 B2 -- 80.6 1/4" 6.35 B2 08387U . 80.6 1/2" 12.7 A3 16455U VK172 Plain Barrel -- 1 25 mm 1 80.6 1 1/2" 1 12.7 1 A3 Approved Temperature Ratings Approved Finishes and "A" Dimensions A 155 ° IQ l7 ,700rS\ ., , - " " ' " ' " 1 - Brass, Chrome-Enloy®, or White Polyester sprinkler with a Brass, Chrome-Enloy® or White "A" Polyester Sleeve and Escutcheon with dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) and 286 °F (141 °C) 2 - Brass, Chrome-Enloy®, or White Polyester with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) B - 155 °F (68 'C), 175 °F (79°C), and 200 'F (93 'C) 3 - Brass, Chrome-Enloy®, or White Polyester with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) Footnotes Part number shown is the base part number. For Complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-131 tees. When selecting other CPVC fittings,' contact Viking Technical Services. FM ADDroval Requirements: The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (includ- ing 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers. Also refer to page DRYI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other simi- lar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. POEM"For 'A' Dimension: A 1. Determine the distance from Outside -.., the face of the diameter: ' tee to the base 1-5/16' of the sprinkler. (33.4 mm) 2. Round up to the (sore as next highest 1/2' 1' (25 mm) (12.7 mm) incre- Schedule merit between 3' 40 pipe). (76.2 mn) and 47' (1,194 mm). 1-5/8° Li (48.3 mm) Figure 5: Plain Barrel Dry Pendent Sprinkler Ambient Exposed Barrel Ambient Temperature Temperature 40°F/4°C150'F/10°CI60-F/16°C of Protected Areaw at thE Exposed Minimum Barrel Discharge End Lemgth*w Face of Tee of the Sprinkle to Top of Ceiling ml In. (mm) 40F (40 0 1 0 1 0 30°F (-1°C> 0 0 20°F (-7°C) 4 (100) 0 0 10F (-12°C) 8 (203) 1(E4) 0°F (-18°C) 12 (305) 3 (76) 0 -10°F (-23°C) 14(356) 4(102) l(25.4 -20°F (-29°C) 14 (356) 6 (152) 3 (76) -30°F (-34°C) 16 (406>8(203 4(102) -40°F (-40°C) 18(457) 0(203)14 (102) -50°F (-46°C) 20(508)10(25416 (152 -60°F (-51C) 20(508)10(25416 (122) Up to 2' (50.8 mm) adjustment available. Note To locate the deflector at the minimum distance below the ceiling with no upward Seal the clearance adjustment avail- able order the space around the dry pendent sprink- sprinkler to avoid (eak- ter 1' (25.4 mm) age of air into the 13/16' protected area and shorter than the 'A' dimension, J' 2O.6 mm) consequent formation the frame, which could notches tion, Refer to Figure r 1(112.7 mm) maximum distance deflector at the 1-1/2' (38.1 mm) Sleeve finish cause premature opera- 4-7/16' To locate the inhibit operation or Ceiling of condensate around J) Note [S , diameter escutcheon 7 below. N below the ceiling Maxi with no downward erature differential able, order the If humidity and 'temp- 1-1 a djustme 3-1/16' nt avail- (Protected Area) causes condensation dry pendent sprink(77.8 mm) on the exposed dry ter 1' (25.4 mm) sprinkler, consider longer than the wrapping the exposed Deflector at 'A' dimension. barrel with insulation, maximum distance foam insulating tape, below ceiling or equivalent. *The protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. w*The minimum required barrel length is not the same as the 'A' dimension, Refer to Figures 3-5 for the 'A' dimension. NDTE Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Install 1 inch NPT threaded end of dry pendent sprinkler (Exposed Minimum into the 1 in NPT outlet of o malleable iron tee fitting per ANSI B 16.3 (Class 150) or cast iron threaded tee fitting per ANSI 16.4 (C(ass 125) only. niriuri ceiling opening diameter 1-3/4' (44,5 mm) LfMaxirnun ceiling opening diameter Barrel) A' 2-1/4' (57 mm), Deflector at minimum distance below ceiling 2-7/16' (61.9 mm) Minimum Sprinkler 105f October 25, 2010 N WNG l:II[.1u.YM QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) S Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_031793 Replaces page 105a-f, dated August 12, 2010. (Revised sprinkler materials.) March 14, 2008 Sprinkler 41 a MICROFAST® AND NIKJW*i I:ilEu7.. MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-401 70 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel Form No. F 081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 0666613, Added Dry System note in approval chart for Small Orifice.) C Sprinkler 41 b March 14, 2008 MICROFAST® AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 1750/792 = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 ¶168 °C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. 02A 1/2' ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Protective Sprinkler Flats C ap 10896 (D Figure 1: Standard Sprinkler Wrench 10896W/B March 14, 2008 Sprinkler 41c MICROFAST® AND "%I I Kj I44I I'll MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286°F (141 °C) 225°F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. 111 F11•1 - Sprinkler Wrench 12144\.I/B** for installing coated and/or recessed pendent sprinklers Carefully slide the with protective cops. wrench sideways around the protective cap, ensuring engage- nent with the sprinkler wrerrk £lnlc. w*A 1/2 ratchet is required (not available from Viking), Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers 0 Sprinkler 41d March 14, 2008 S MICROFAST®AND MicrofastHP® QUICK I I RESPONSE PENDENT I SPRINKLERS I The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com I I rinkler Thread Size Nominal Overall Listings and Approvals3 I Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. I metric2 Inches I mm I cULus4 I FM5 I NYC, JVdS LPCB CE I Standard Orifice 06662B [vK302 1/2" 115mm 1 5.6 1 80.6 1 2-1/4" 1 58 1 AiX, BIY I A3X, 133Y AiX, B1Y A3 A3X, 133Y C3X, E3Y13 C3X, E3Y15 Large Orifice 06666B VK352 3/4" 20 mm 80 115.2 2-3/8" 60 AiX, B1Y A2X, 132Y AiX, B1Y -- A3X C313 12104 VK352 3/4" 20 mm 8.0 115.2 2-1/4" 58 -- -- -- G3 -- -- -- 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 AiX, B1Y - AiX, B1Y A3 -- -- -- Small Orifice' 067181310 VK329 1/2" 15 mm 28 40.3 2-3/16" 56 Ai X, B1Y A2X AiX, B1Y -- -- - -- 06720B10 VK331 1/2" 15 mm 4.2 60.5 2-1/4" 58 AiX, B1Y -- AiX, B1Y -- -- - -- 06932B VK331 -- 10 mm 4.2 60.5 2-3/8" 60 -- -- -- A3 -- G214 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metric' Inches mm cULus4 FM NYC" VdS LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 AiX, B1Y - AiX -- -- - -- Maximum 250 PSI (17 bar) WWP Small Orifice' 1229010 1 VK342 1/2" 115 mm 1 2.8 I 40.3 I 2-3/16" 56 1 AiX, B1Y I - Al X -- I -- - -- Approved Temperature Ratings Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), Approved Finishes X - Standard surface-mounted escutcheon or 1 - Brass, Chrome-Enloy®, White Poly- the Viking Microfast® Model F-i Adjustable B - 135 °F (57 °C), 155°F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) 8 ester7 , Black Polyester79, and Black Escutcheon12 °F °C), °F C - 155 °F (68 °C), 175 °F (79 °C), 200 (93 and 286 Teflon®7 Y - Standard surface-mounted escutcheon or °C) (141 D - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F 2 - Brass and Chrome-Enloy® the Viking Microfast® Model F-i Adjustable (141 °C) 3- Brass, Chrome-Enloy®, White Polyester8, Escutcheon 12 or recessed with the Viking :g g and Black Polyester8 Micromatic® Model E-i or E-2 Recessed Escutcheon G - 155 °F (68 °C) ________________________________ Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. 8 Other colors are available on request with the same Listings and Approvals as the standard colors. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. "Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. 12The Viking Microfast® Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 13(( Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 14 (( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-401 30 and 0786-CPD-40170. 15 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1 008. a a E March 14, 2008 Sprinkler 41e MICROFAST® AND NIKJ i:lIIyM MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com 1,ith cULus Listing Requirements: Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Approval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size 2-5/16" (58.7 mm) minimum I 2-1/8" I 2-1/2" (63.5 mm) NaXUIAm (54 ) 1/2' (15 mm) NPT N31 OIL\ A 2-1/4" 1-5/8" (58 mm) (41 mm) I1) 2 lI II Ill 1-1/2" (38.1 mm) (50.8'7") Ik. II/ Minimum Maxmum Installed with a Microfast Model F-i Adjustable Escutcheon Pendent Sprinkler 06662B (VK302) Installed with a standard 1/8" surface- mounted escutcheon, Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 0 Sprinkler 41f March 14, 2008 MICROFAST® AND I MicrofastHP® QUICK I N I F(AI F1G l:II[1•.yv RESPONSE PENDENT I SPRINKLERS I The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com 2-1/8" I Ceiling Opening Size: I 2-1/8" I I— H (54 p) 2-5/16" (587 mm) minimum i (54 mm) 2-1/2" (63,5 mm) maximum n MUM\ __ 13/4 1_1/846 mm) mm) Maximum M)Gx1mum 7t Installed with a Micromatic Model E-1 Recessed Escutcheon Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F 081296 Replaces page 41 a-f, dated October 12, 2007. (Added LPCB Approval and updated CE - Approval for Sprinkler 0666613, Added Dry System note in approval chart for Small Orifice.) S ~~MmmnILTAn S Schedule-10/Schedule-40 - ABF11 Fully Listed and FM Approved Sprinkler Pipe When you specify Allied Schedule-10/Schedule-40 - ABFII sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40-ABFll gives you the extra quality assurance you demand. Our Sch-10 (11/4"-8") pipe and Sch-40 (1"- 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-10/Schedule-40 -ABFII product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-i 23. > Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. . The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFII". In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* American Made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. > Specifications & Approvals Schedule-10/Schedule-40 - ABFII pipe are in compliance with the following: ASTM A-i 35, Type E Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture NPS - Nominal I.D. Wt. Wt. (H20 Filled) - CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/m - 1.049 1.680 2.05 - 1 25 26.6 2.5 3.05 - - 11/4 1.380 2.270 2.93 1 32 35.1 4.36 4.36 - 11/2 2.720 3.61 1 40 40.9 4.0 5.37 - 2.067 3.650 5.13 1 50 52.5 5.4 7.63 - 21/2" 2.469 5.790 7.86 1 65 62.7 1 8.6 11.73 - 1 ([jfl NI'S - - Nominal I.D. Wt. - Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/rn lbs/Ft; kg/rn - 11/4 1.442 1.810 2.525 7.0955 - 32 36.6 - 2.7 3.75 - 11/2 2.080 3.04 - 5.6570 40 42.7 3.1 4.52 - 2.157 2.640 4.22 4.5827 50 54.8 3.9 6.28 - 21/2" 2.635 3.530 5.89 -- 3.5196 65 66.9 5.3 8.77 - 3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 - 4.260 5.610 11.78 1.6020 100 108.2 8.3 17.53 - 5.295 -_134.5 - 7.77 17.33 1.4874 125 11.56 25.80 - 6.357 9.290 23.03 1.0251 150 161.5 13.8 - 34.27 - 8' 8.249 16.490 40.15 1.8365 - 200 209.5 24.5 - 59.75 - * See ABFII warranty APPROVED . Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com 9~al hed • 161005 Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT' Harvey, It. 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 02011 Atkore International, Inc. All Rights Reserved. STP-S5-3-1105 (q (~~ <@> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 FITTINGS .I A Division ofStar Pips P,das S C.I. THREADED FITTINGS CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTMA126 CLASS B. DIMEN- SIONS CONFORM TO ANSI B16.4 CLASS 125 EXCEPT PLUGS CONFORM TOASME B16.14. THREADS ARE NPT PER ANSI/ASME B1.20.1. Ti71}CAS CASTIIIRONII.1 DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. A DIM B4SI 7BPIECE 1 CB90033 300 1 11/4 1.50 CB90044 300 1 11/2 1.75 CB90055 300 1.94 1 2 1 CB900661 300 1 2.25 1 2.25 1 2.90 2 1/2 CB90077 300 2.70 2.70 4.75 CAST IRON RED. COUPLING NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIM B'ISION WEIGHT EACH A PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 CAST liIRON I;1; ''DEG. ELBOW NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WBGFff EACH PIECE A B 1X112 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1 1/2X1 CB90053 300 1.65 1.80 1.51 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 C890064 300 1.90 1 2.10 2.30 2X1 1/2 CB900651 300 1 2.02 1 2.16 1 2.60 Page 38 T IRONISTRAIGHT TEE NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. IDIMENSIONSl WEIGHT 1 EACH PIECE A B 1 CT333 300 1.50 1.50 1.21 11/4 CT444 300 1.75 1.75 1.87 11 CT555 300 1.94 1.94 1 2.51 2 CT666 300 225 2.25 3.96 21/2 CT777 300 2.70 2.70 1 6.45 CAST IIRON 45 DEGREE ELBOW NOMINAL SIZE (INCH) I ITEM CODE # MAX. WORKING P.S.I. IDIMIONSI WEIGHT I EACH PIECE A B 1 CB45033 300 1.12 1.12 0.84 11/4 . CB45044 300 1.29 1.29 1.40 11/2 CB450551 300 1 1.43 1.43 1.80 2 1 CB450661 300 1 1.68 1.68 2.79 L1: UM-,91 CAST IRON IPLUGS NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPL004 300 1.36 0.44 11/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 C.I. THREADED FITTINGS S \;A pfrnNGs (q (q~ <S> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST lIRON KCROSS NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMB1SIONSI WEIGHT1 EACH PIECE A B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 CASTIIRONIREDUCING TEE NOMINAL I SIZE (INCH) ITEM I CODE _______ MAX. WORKING P.S.I. I DIMB1SIONS WEIGHT EACH PIECE A B C 1X1X1I2 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 UT-33-5 300 1.80 1.80 1.65 1.73 1 1/4X1X1/2 CT431 300 1.34 1.26 1.53 1.17 1 1/4X1 X314 CT432 300 1.45 1.37 1.62 1.38 1 1/4X1X1 CT433 300 1.58 1.50 1.57 --T.747- 1 1/4X1X1 1/4 CT434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X314 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 1/4X2 CT-4476- 300 2.10 2.10 1.90 2.55 1 1/2X1 X1/2 CT531 300 1.41 1.34 1.66 1.41 1 1/2X1 X3/4 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1 X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1.88 2.00 1 1/2X1X1 1/2 CT535 300 1.94 1.80 1.94 2.30 1 1/2X1 1/4X1/2 CT541 300 1.41 1.34 1.66 1.58 1 112X1 1/4X3/4 CT542 300 1.52 1.45 1.75 1.72 1 1/2X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 1 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 11.76'- 1 1/2X1 1/2X3/4 CT552 300 _1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 _1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 _1._ 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1 X2 CT636 300 2.25 2.02 2.25 1 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1 1.49 1.88 1 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 1 CT665 300 2.02 2.02 2.16 3.72 2x2x2 1/2 1 CT667 300 2.60 2.60 2.39 5.10 Page 39 FIG. 7045 Clamp-T, FPT Branch c®Us APPROVED For Listings/Approval Details and Limitations, visit our websito @ w.anviIintI.vom or contact an Anvii/AnviiSStar Sales Representative. The Gruvlok Clamp-I provides a quick and easy outlet at any location along the pipe. A hole drilled or cut in the pipe to receive the locating collar of the Clamp-I is all that is required. The full, smooth outlet area provides for optimum flow characteristics. The Clamp-I housing is specially engineered to conform to the pipe O.D. and the Clamp-I gasket providing a leak tight reliable seal in both positive pressure and vacuum conditions. The maximum working pressure for all sizes is 500 PSI (34.5 bar) when assembled on standard wall steel pipe. The Gruvlok Clamp-I provides for a branch or cross connection in light wall or standard wall steel pipe. The Fig. 7045 Clamp-T female pipe thread branch is available with NPT or ISO 7/1 connection and the Fig. 7046 Clamp-T has grooved-end branch connection. Clamp-T cross connections are available in various sizes allowing greater versatility in piping design. NOTE: Variable End Configurations are Possible - Thd xThd and Gr. xlhd. Sizes - 2" x 1/2" through 8" x 4" I M1t'M':ft1II Branch Size Fig. 7045 Threaded Branch Equiv. Pipe Inches U. Value Length Feet ON/mm Meters 22 1.0 15 - 0.3 3/4 25 2.0 20 - 0.6 1 44 2.0 25 - 0.6 11/4 76 2.5 32 - 0.8 11/2 89 4.0 40 - 1.2 2 164 3.5 50 - 1.1 21/2 152 12.5 65 - 3.8 3 318 8.5 80 - 2.6 4 536 8.0 100 - 2.4 MATERIAL SPECIFICATIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts are zinc electroplated followed by a yellow chromate dip. U-BOLT: Cold drawn steel and zinc plated. STAINLESS STEEL BOLTS & NUTS: Stainless steel bolts and nuts are also available. Contact a Gruvlok Representative for more information. HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12 or Malleable Iron conforming to ASTM A 47, Grade 32510. COATINGS: Rust inhibiting paint Color: ORANGE (standard) • Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: R.AL3000 and RAL9000) For other Coating requirements Contact a Gruvlok Representative for more information. GL-2.1 0 GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade "E" EPDM (Green color code) 40F to 230"F (Service Temperature Range)(-40"C to 110"C) Recommended for water service, diluted acids, alkalies solutions, oil- free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade "1" Nitrile (Orange color code) -20T to 180"F (Service Temperature Range)(-29C to 82"C) Recommended for petroleum applications, air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR. LUBRICATION: Standard Gruvlok Gruvlok XtremelM (Do Not use with Grade "1.") I IIIEGT.1 LQK 0 LB RN i!EIIO7VJ1IiL'EiiiS11I FIG. 7045 Clamp-T, FPT Branch 1DI iii liii Fig. 7045 -Y _Z_ F -1 - r 1 Fig. 7045 (U-Bolt) FIGURE BRANCHI(TABLE Cs) II U $ TOIINEXT PAG1 I I Hole Dimensions V Max. Clamp-T Dimensions Specified Torque § Approx. Nominal Size O.D. Working Pressure I U V Threaded W Y Z Bolt Size Wt. Each Mix. Diameter Max. Diameter Mm. Max. In.JDN(mm) In/mm In ./mm In1mrn PSI/bar lnlrnrn 1,11mm lnlmm In1mm In1rnm 1,11mm In 1mm__- Ft-Lbs/N-rn LbsiKg 2 x 1/2 2.375 x 0.840 11/2 1/, 500 23A 'Au 2% '/ 5'/2 3 1/, U-Bolt 30 40 2.3 50x15 60.3x21.3 36 41 34.5 56 14 67 12 140 76 - 1.0 2 x 3/4 2.375 xl .050 1½ 1/x 500 2'A6 'A6 2% 1½ 5½ 3 ½ U-Bolt 30 40 2.3 50x20 60.3x26.7 38 41 34.5 52 14 67 38 140 76 - 1.0 2 xl 2.375 xl .315 11/2 1% 500 1'5A6 'A6 2/x 1½ 5½ 3 ½ U-Bolt 30 40 2.6 50x25 60.3x33.7 38 41 34.5 51 14 67 38 140 76 - 1.2 2 xl ¼ 2.375 xl .660 2 21/8 500 23An 'An 2/8 1½ 5½ 3½ ½ U-Bolt 30 40 2.7 50x32 60.3x42.4 51 54 34.5 55 14 73 38 140 89 - 1.2 2 xl ½ 2.375 xl .900 2 2Yx 500 23An 'Ax 2'/e 1½ 7 3½ ½ U-Bolt 30 40 2.5 50x40 60.3x48.3 51 54 34.5 55 14 73 38 178 89 - 1.1 21/2 x ½ 2.875 x 0.840 11/2 1% 500 2%6 'Au 2'/x 1% 51/2 3 ½ U-Bolt 30 40 3.0 65x15 1 73.0x21.3 38 41 34.5 62 14 73 44 1 140 76 -1.4 2½ x 3/ 2.875 xl .050 11/2 1% 500 25/in 9Ae 2'/e 1% 5½ 3 ½ U-Bolt 30 40 2.9 65x20 73.0x26.7 38 41 34.5 59 14 73 44 140 76 - 1.3 21/2 x 2.875 x 1.315 11/7. 1% 500 2'/in 'An 2'/8 1% 6'/x 3 ½ U-Bolt 30 40 2.9 65x25 73.0x33.7 38 41 34.5 55 14 73 44 156 76 - 1.3 21/2 xl 1/4 2.875 xl .660 2 21/8 1 500 27Ae 'An 3% 1Y4 61/8 3% ½ U-Bolt 30 40 3.4 65x32 73.0x42.4 51 54 34.5 62 14 79 44 156 86 - 1.5 21/2 xl ½ 2.875 xl .900 2 21/8 500 2?/i6 'A6 3½ 1% 6'/x 3% ½ U-Bolt 30 40 3.4 65x40 73.0x 48.3 51 54 34.5 62 14 79 44 156 86 - 1.5 3 x ½ 3.500 x 0.840 1½ 1% 500 2'Ae 'An 3 2½ 7 33% ½ U-Bolt 30 40 2.8 80x15 88.9x21.3 38 41 34.5 65 14 76 54 178 95 - 1.2 3 x % 3.500 xl .050 11/2 1% 500 2'A6 'An 1 3 21/8 7 3% ½ U-Bolt 30 40 2.7 80x20 88.9x26.7 38 41 34.5 62 14 76 54 178 95 - 1.2 3 x 3.500 xl .315 1½ 1% 500 2/in 'An 3 21/, 7 3% ½ U-Bolt 30 40 2.7 80x25 88.9x33.7 38 41 34.5 59 14 76 54 178 95 - 1.2 3 xl ¼ 3.500 xl .660 2 21/8 500 2'Yi6 11/2 3% 21/8 6/n 3% ½x 23/4 80 100 3.4 80x32 88.9x 42.4 51 54 34.5 68 38 86 54 175 95 - 1.5 3 xl ½ 3.500 xl .900 2 2% 500 21A7 1½ 3% 2% 6'/e 3% ½ x 2~/4 80 100 4.4 80x40 88.9x 48.3 51 54 34.5 68 38 86 54 175 95 - 2.0 3 x 2 3.500 x 2.375 2½ 2% 500 211A6 1½ 3% 21/a 6% 41/s ½ x 2% 80 100 4.6 80x50 88.9x 60.3 64 67 34.5 68 38 86 54 175 105 - 2.1 4 x ½ 4.500 x 0.840 11/2 1% 500 31Ae 'An 3½ 2% 7% 33% ½ U-Bolt 30 40 2.9 100x15 114.3x21.3 38 41 34.5 76 14 89 67 197 1 95 - 1.3 4x% 4.500 xl .050 1½ 1% 500 31A6 'An 3½ 2% 7% 3% ½ U-Bolt 30 40 2.8 100x20 114.3x26.7 38 41 34.5 78 14 89 67 197 95 - 1.3 4 x 4.500 x 1.315 1½ 1% 500 213An 'An 3½ 2/n 7% 3% ½ U-Bolt 30 40 2.7 100x25 114.3x33.7 38 41 34.5 73 14 89 67 197 95 - 1.2 4 xl ¼ 4.500 xl .660 2 21/8 500 33A6 1/x 3'/a 2% 71/2 33% ½ x 2% 80 100 4.5 100x32 114.3x42.4 51 54 34.5 81 48 98 67 191 95 - 2.0 4 x 11/2 4.500 xl .900 2 21A 500 33An 1/8 37/8 2% 71/2 3% ½ x 21/4 80 100 4.6 100x40 114.3x48.3 51 54 34.5 81 48 98 67 191 95 - 2.1 4 x 2 4.500 x 2.375 21/2 2% 500 3/16 17/8 4 2% 7½ 41/8 ½ x 2% 80 100 7.7 100x50 114.3x60.3 64 67 34.5 84 48 102 67 191 105 - 3.5 4 x 21/2 4.500 x 2.875 2% 27/8 500 311A6 1'/x 4 2% 7½ 4% ½ x 2% 80 100 5.2 100x65 114.3x 73.0 70 73 34.5 78 48 102 67 191 111 - 2.4 4x3 0.0. 4.500x2.996 014 2'% 500 3 1½ 4 2'/n 7.4 4% ½x2'14 80 100 5.2 100x80 114.3x76.1 70 73 34.5 76 48 102 67 191 111 - 2.4- 4 x 3 4.500 x 3.500 31/2 3% 500 31/4 1'/8 41/4 2'/8 71/2 51% ½ x 31/2 80 100 6.5 100x80 114.3x88.9 89 92 34.5 83 48 108 67 191 133 - 2.9 NOTE: 21/2 ', 5" and 6" Num. Run pipe size Clamp-T may be used on 3' O.D., 51/2' O.D. and 6/2' O.D. pipe (Additional larger sizes on next page.) V Based on use with standard wall pipe. Not for use in copper systems. See Installation & Assembly directions on page 163. § -For additional Bolt Torque information, see page 184. ®4NJ1L: k'ni GL-2.10 S F-11 11 wllfi~@'Uumff ~5 FIG. 7045 Clamp-T, FPT Branch rig. iu F -f- Z T7~ F r- Zn-1 7 U Fig. 7045 (U-Bolt) S FIGURE 7045-FPT BRANCH (CONTINUED FROM PREVIOUS PAGE) I I Hole Dimensions V Max. Clamp-I Dimensions Specified Torque § Approx. Nominal Size O.D. Working Bolt Size Wt. Each - - __________ - Mix. Diameter Max. Diameter Pressure I U V Threaded W V Z Max. -_Mm. tn./DN(mm) !nimm InJmm In/mm PSL/bar InJmm Inirnrn InJrnrn Inirnm In/mm minim mInim Ft-Lbs/N-rn LbsiXg 5 x 11/4 5.563 x 1.660 2 21/8 500 3W16 1/8 4% 31/4 91/8 3~ % a 314 100 130 5.4 125x32 141.3x42.4 51 54 34.5 94 48 111 83 232 95 - 2.4 5 xl ½ 5.563 xl .900 2 21/8 500 3'1Aa 1% 4/8 31/4 91/8 33% % x 31% 100 130 5.5 125x40 141.3x48.3 51 54 34.5 94 48 111 83 232 95 - 2.5 5 x 2 5.563 x 2.375 21/2 2% 500 313/6 1% 41/2 31% 91% 41% % x 31/4 100 130 5.7 125x50 141.3x60.3 64 67 34.5 97 48 114 83 232 105 - 2.6 5 X 21/2 5.563 x 2.875 2/4 21/8 500 313/16 17/8 4% 31/4 91/a 4% Vax 31/4 100 130 7.0 125x65 141.3x73.0 70 73 34.5 97 48 121 83 232 111 - 32 5x30,D, 5.563x2.996 2314 2% 500 3~ 1% 4Y4 3¼ 9¼ 4Y~ 114X4V2 130 180 7.0 125 x 80 141.3 x 76.1 70 73 34.5 95 48 121 83 232 111 - 3.2 5 x 3 5.563 x 3.500 31/2. 3% 500 4 17/8 5 31/4 91% 51/4 % x 31/4 100 130 8.7 125x80 141.3x 88.9 89 92 34.5 102 48 127 83 232 133 - 3.9 6 x 11/4 6.625 x 1.660 2 21/8 500 4Via 2 47/8 37/8 101/8 3% % x 41/4 100 130 7.8 150x32 168.3x 42.4 51 54 34.5 106 51 124 98 257 95 - 3.5 6 xl 1/2 6.625 xl .900 2 21/a 500 43/1a 2 47/8 37/8 101/8 3% % x 41/4 100 130 7.8 150x40 168.3x 48.3 51 54 34.5 106 51 124 98 257 95 - 3.5 6 x 2 6.625 x 2.375 21/2 2% 500 43X6 2 47/s 37/8 101/8 41/8 % x 41/4 100 130 7.8 150x50 168.3x 60.3 64 67 34.5 106 51 124 98 257 105 - 3.5 6 x 21/2 6.625 x 2.875 21/4 2/ 500 4/is 2 51% 37% 101/a 4% % x 41/4 100 130 8.4 150x65 168.3x73.0 70 73 34.5 106 51 130 98 257 111 - 3.8 6x30.D. 6.625x2.996 2A 2% 500 4¼ 2 5'/8 3 18 10¼ 4Y8 5/xX4¼ 100 130 8.4 150 x 80 168.3 x 76.1 70 73 34.5 105 51 130 98 257 111 - 3.8 6 x 3 6.625 x 3.500 31/2 3% 500 4% 2 5% 37/8 101/8 51/4 % x 41/4 100 130 9.6 150x80 168.3x88.9 89 92 34.5 111 51 137 98 257 133 - 4.4 6 x 4 6.625 x 4.500 41/2 4% 500 4% 2 51/2 37/8 101% 61/2 % x 41/4 100 130 10.5 150x100 168.3x114.3 114 117 34.5 111 51 140 98 257 165 - 4.8 8 x 2 8.625 x 2.750 21/2 2% 500 5316 21/4 57/8 5 121/4 41% % x 41/4 130 180 11.3 200x50 219.1x70.0 64 67 34.5 132 57 149 127 324 105 - 5.1 8 x 21/2 8.625 x 2.875 2/4 21/8 500 55A6 21/4 61/4 5 12% 4% % 1(41/2 130 180 11.1 200x65 219.1x73.0 70 73 34.5 134 57 159 127 324 111 - 5.0 8x30.D. 8.625x2.996 21% 2/e 500 5¼ 2¼ 6¼ 5 12314 4Y8 Y4x4½ 130 180 11.1 200 x 80 219.1 x 76.1 70 73 34.5 133 57 159 127 324 111 - 5.0 8 x 3 8.625 x 3.500 31/2 3% 500 5% 21/4 6% 5 123/4 51/4 3/4 x 41/2 130 180 13.0 200x80 219.1x88.9 89 1 92 1 34.5 137 57 162 127 324 133 - 5.9 8x4 8.625x4.500 41/2 4% 500 5% 1 21/4 61/2 5 123/4 61/2 %x4½ 130 180 16.2 200x100 219.1x114.3 114 1 117 1 34.5 137 57 165 127 324 165 - 73 NOTE: 21/2, 5" and 6 Nom. Run pipe size Clamp-I may be used on 3' 0.D., 51/2 O.D. and 61/2" O.D. pipe (Additional smaller sizes on previous page.) V Based on use with standard wall pipe. Not for use in copper systems. See Installation & Assembly directions on page 163. § - For additional Bolt Torque information, see page 184. GL-2.10 Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed gnly when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 C@ US USTEO OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800 786.5266 wwwtolco.com C@ US usitu Fig. 78 - All Steel Ceiling Plate Size Range - 3/8 rod Material - Carbon Steel Features - Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Additionally, (UL) has listed the Fig. 78 with fasteners as shown in the table below. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Patent #5,702,077 UL Listed Fastener Table Pipe Size City Fastener Type Material 1/2 -2 21/2 4 1/2 -2 2 2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw 1/4 x 11/2 wood screws* 1/4 x 1 tek screws Wood Wood Metal (18 gauge) 1/2 -2 1/2 -2 2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw #14 x 2 A-point-hex-washer-head sheet metal screw Wood Wood thru 5/8 gyp board * No pre-drilling Dimensions • Weights Pipe Size A Max. Rec. Approx. B C D E Load Lbs.* WtJ100 1/2-2 5 - 6 . * Minimum safety factor of 5 3 2½ 1½ 5/16 3/8 Consult factory for data 150 15 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 82879 • PH 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800 786.5266 www.tolco.com Component of State of California OSHPD Approved Seismic Restraints System -- FIG. 98 FIG. 98B Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8 thru 7/8 hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO C'. t-- ;A Seismic flLlIItL JyLIuIo UIUIuII Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8 thru 7/8 rod in is 1 increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100- All Thread Rod Full Length Size Range - Secures 3/8 thru 1112 rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F wt./100 1/4 3/8 1/2 240 730 1350 12 29 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951 737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 200 - "Trimline" Adjustable Band Hanger C® US USThD Fig. 200R (Import) - "Trimline" Adjustable Band Hanger wlRetainer Ring Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2 thru 2') Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2 thru 8') Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mu. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 2/8 400 12 11/4 3/8 8mm or 10mm 33/4 2/s 400 13 11/2 3/8 8mm or 10mm 3/8 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 5/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 6/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 961.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Not loss than Wood Flooring 2" nominal width lltl/2"l Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. Wood efrock 1/4 8002957 /251100 1/4x1 210 (7116"058) 25 125 1/4" 8003957 GST 200 1/4x2" 1760 (Fir) 25 125 1/4 8004957 GST 300 1/4 x 3 (F) 25 125 1 3/8" 8006957 GST .75 1/4 x 3/4" 564 (314' Ply) 25 125 3/6" 8007957 GST 10 1/4 xi" 210 (7116" OSB) 300 25 125 U FM 3/8' 8008957 GST 20 114x2" 1760 (Fir) 850 1475 25 125 3/8 8068925 GST20SS 1/4x2 1760 (Fir) 850 25 125 1 3/8" 8009925 GST 25-380 3/8x2-1/2 2113 (Fir) 1500 25 125 3/6" 8010957 GST 30 1/4 x 3" 2060 (F)) 1500 1475 25 125 1Nut Driv Black er 3/8" 8069925 GST30SS 1/4x3" 2060 (Fir) 25 125 Part #8113910 3/8" 801192fi GST 40 1/4x4 2180 (Fir) 25 125 1 3/8' 8012925 GST 60 1/4x6" 2230 (Fir) 25 125 - 1/2" 8013925 GST2 1/4x2 1760 (Fir) 25 125 1 1/2" 8014925 GST 2.5-380 3/8x2-1/2" 2113 (Fir) 25 125 1/2" 8015925 /2513 1/4x3 _Jfir 25 1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 1/2" 81792 GST 6 1/4 x 6 2230 (Fir) 25 125 1 #14 SW Red Nut Driver Part# 8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3%" x 12 pitch roof. • Reduces installation cost Allows 17" deflection from vertical. • Made in the U.S.A. Ij #14 Black Not Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin.off feature which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.sammysuperscrew.com 4 is A %W I€ u. 3/8" 8139957 SH-GST20 1/4x2" 1257 (Fir) 1050 1415 25 125 3/8" 8141957 SH-GST30 1/4x3" 1720 (Fir) 1500 1475 25 125 Product Features No pie-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. Not less than 2" nominal width / (1-1/7) up to 3-1/7 pipe; not less than 7(2-1/7) nominal width 4" & 5" pipe I I Minimum 2-l/2" from bottom for branch lines. Minimum 3" from bottom for main tines. Exception: This requirement shall not apply to 2" or thicker nailing ships resting on top of steel beams. t A Floor Joist S - #14 SW Red Nut Driver 1/4" 8018957 SWG 100 1/4u1" 622 (Fi0 25 125 1/4 8019957 SWG 200 1/4u 2" 1725 (Fir) 25 125 3/8" 8020957 SWG 10 1/4 x1" 622 (FiQ 300 25 125 3/8 8021957 SWG 20 1/402" 1725 (Fir) 1050 25 125 EIII 3/8 8073925 SWG 20 SS 1/4x2 1725 () 850 25 125 4.. 3/8" 8022925 SWG 25-380 3/85 2-1/2' 2249 (Fir) 1500 25 125 1 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Part # 8114910 Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8' 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlln steel Insert the appropriate nut driver into a 3/8" or 1/2" portable drill Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlln steel. FiF1i1i tar SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. ft3 o\0 13-222 INSTALLATION OF SPRINKLER SYFEMS \ ) 0 Contractor's Material andTeèt Certificate for Aboveground Piping 46, - PROCEDURE .• Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by the property owner or" their authorized agent. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certifIcate shall be tilled out and signed by both representatives. Copies shall be prepared tórappro4ng authorities. owneri and 016 contractor. It Is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Properlyname/quj7/J i..A-Q) (i-'Pe- Z'6*Data Property address 0 ,Z C1~81 (-4 qz/•2do' Accepted by approving authorities (names) f1) F 1) Address Plans Installation conforms to accepted plans ''es Q No Equipment used Is approved Li Yes Q No If no, explairt deviations Has personin charge of fire equipment been instructed as EJYes CjNo to location of control valves and care and maintenance of this new equipment? If no. explain Instructions Have copies of the following been left On the premises? System components lnsttucticins Caxe and malflterianceinstnzctiOas I'1FPA25 []Yes ( No UYes EJNo Yes Ci No Lives UNo Location of system Supplies buildings Year of Make Model manufacture . Orifice size - Quantity :TemPrature rating Sprinklers tII2 20!'!) 1/2.. v , (A.) O- %JI( C- 2- 2Ce i I /2-00 Pipe and •Type ofpipe fittings Type of fittings Medmum time to operate Alarm Maim device thro.ugh test connGQWvalve or n Tflowype Make Model. Minutes .. Seconds - Indicator 1 - Dry pipe operating test Make. Model. Serlaino. Make Modal: . Serial no. Time to trip . Time water Alarm through test - Water Air Tsp point reached operated conneclJona,b pressure•. pressure air pressure . estouUet&b propedy - Minutes I Seconds psi psi Psi Minutes I Seconds Yes ( No. 11f no, explain 02006 National Fire Protection Association a Measured frqm time inspector's test connection Is opened b NFPA 13 only requires the 60-second limitation in specific sections FIGURE 24.1 Contractor's Material and Test Certificate for Aboveground Piping NFPAI3(p. 1 of 3) 2007 Edition SYSTEMS ACCEPTANCE Operation - - . Pneumatic Electric OHydraulics. supervised 0-Yes CiNo I Piping Detecting media supervised IJves CJNo Does valve operate from the manual trip,-remote, or both. U Yes 0 No Deluge and preaction valves . control stations? Is there an accessible facility in each circuit for testing? Uves El No If no, explain Does each circuit operate Does each circuit operate . Maximum time to Make Model supervision loss alarm? valve release? gpgrate ielease Yes No Yes No Minutes Seconds Pressure Location and floor. Make and model Setting . . Static pressure Residual pressure (flowing) Row rate reducing valve test Inlet (psi) Outlet (psi) Inlet (psi) Outlet (psi) Flow (gpm) i:iydrostati Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) fOr 2 hours 0r50 psi (34 ) Test above stattcpressure in excess of 150 psi (10.2 bar) for 2 hours. Differential dry-pipe valve clappers shall be left rlthe test to prevent damage. All aboveground piping leakage shall be stopped. description. Pneumatic: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1½ psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed l½ psi (0.1 bar) in24hours. - All piping hydrostatically tested at 200 psi ( bar) for . hours If no, state reason Dry piping pneumatically tested U Yes u No Equipment operates property Q Yes EJ No Do you certify as the sprinkler contractor thatadditives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? UYes UNo Tests Drain test I Reading of gauge located near water supply test cot riection.. psi (_. bar) Residual pressure with valve In test connection open wide: - psi (_ bar) Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping Verified by copy of the Contractor's Material and Test Ci Yes U No Other Explain Certificate for Underground Piping. Flushed by installer of underground sprinkler piping (] Yes Ci No If powder-driven fasteners are used in-concrete, U Yes U No If no, explain has representative sample testing been satisfactorily completed? Blank testing Number used FLocaons . . Number removed gaskets . Welding piping Ci Yes Ci No lf yes ... Do you codify as the sprinkler contractor that welding procedures used complied with U Yes U No the minimum riuirements of AWS B2i, ASME Section IX Welding and Brazing Qualifications, or other applicable qualification standard as required by the AHJ? Do you certify that all welding was performed by welders or welding operators Q Yes Ci No quaiifled In accordance with the minimum requirements of AWS 82.1, ASME Section Welding IX Welding and Brazing Qualifications,-or other applicable qualification standard as required by the Al-ti? -. Do you Codify that the welding was conducted in compliance with a documented UYeS ONo quality control procedure to ensure that (1) all discs are retrieved; (2) that openings In piping are smooth, that slag and other welding residue are removed; (3) the internal diameters of piping are not penetrated; (4) completed welds are free from cracks, Incomplete fusion, surface porosity greater than Vie in. diameter, undercut deeper than the lesser of 25% of the wall thickness or Ya In.; and (5) completed circumferential butt weld reinforcement does not exceed 3 in.? © 2006 National. Fire Protection Association . NFPA 13. 2-of 3) FIGURE 24.1 Continued 2007 Edition flGUB1 24.1 Conthwed 2007 Edition INSTALLATION OF SPRINKLER SYSTEMS U-224