Loading...
HomeMy WebLinkAbout6231 YARROW DR; ; FA120030; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA120030 Job Address: 6231 YARROW DR Permit Type: FALARM Parcel No: 2130502000 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 7/10/2012 Approved: 7/13/2012 Issued: 7/13/2012 Inspector: Project Title: OSTENDO TECHNOLOGIES T.I. Applicant: Owner: JJJ ENTERPRISES RIF Ill YARROW DRIVE II LLC 533 S VINEWOOD ST 11620 WILSHIRE BLVD #300 ESCONDIDO CA LOS ANGELES CA 760-747-3050 Fees ($) Add'I Fees ($) Total ($) Balance ($) 257 0 257 0 DF-60601 Al • Al -60 MS-9200UDLS(E) Rev 3 Intelligent Addressable FACP with Built-In Communicator (2) Flre•LITeAtarms by Honeywell W'daVes—saKi-elFir—eTAla—r—mTC7o—nfr—olI an . . W1_ The Fire-Lite MS-9200UDLS Rev 3 with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UDLS Rev 3 may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeedTM mode—Fire•Lite's latest polling technology—for a quicker device response time. LiteSpeed's patented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With Litespeed polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The MS-9200UDLS Rev 3's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, additional secondary ANN-BUS, and increased power for the resettable and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools—the Fire•Lite Upload/Download software kit—may serve as a Service Termi- nal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices, AD355 (LiteSpeed), USB port, NAC circuit diagnostics, a new report has been added to the walk- test that lists untested devices, new device types added: audio telephone type code for ACC 25/50ZST, Photo Supervisory and auto-resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9200UDLS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACPs (Fire Alarm Control Panels). Features Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local USB port upload/download, using PS- Tools. Four (4) Style Y (Class B) NAC circuits, which can be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or LCD-80F, ANN-80 or Legacy ACS Annunciators. ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): - ANN-80(-W) Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module - ANN-RLED Annunciator Module alarms only - ROME Relay Option Module Enclosure ACS/TERM: - ACS Annunciators: Up to 32 Legacy ACM Series annun- ciators (ACM-16AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. - Terminal-mode Annunciators: Up to 32 Legacy LCD-80F remote annunciators. DF-60601 Al • 12/07/2010 - Page 1 of 6 EIA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6E Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterfiow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 m.). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NA CS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PS-Tools, separately). Upload/ download system programming locally to the MS- 9200UDLS Rev 3 in less than one minute. USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information MS-9200UDLS: 198-point addressable Fire Alarm Control Panel, one SLC loop, Includes 80-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. 120 VAC operation. MS-9200UDLSE: Same as MS-9200UDLS, except with 240 VAC operation. 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style Y (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PK-CD Programming software for Windows®-based PC com- puter (cable not included), available on www.firelite.com. DP-9692: Optional dress panel for MS-9200UDLS Rev 3. TR-CE: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB- 55F for mounting. BAT Series: Batteries, see data sheet DF-52397. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with MS-9200UDLS Rev 3(E). PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming and updating panel firmware. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for Internet communications over customer provided ethernet Internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static I (See data sheet DF-60407 or DF-52424 for more information.) Page 2 of 6— DF-60601 Al • 12/07/2010 IPBRKT: Mounting kit for IPDACT-2/2UD in common enclo- sure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD dis- play. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure (see DF-60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DF- 5243 1.) ROME: Relay Option Module Enclosure. Provides one ANN- RLY Relay Module already installed. The ROME Series pro- vides mounting space for one additional Relay Module or one addressable Multi-module. (See Installation Sheet PN 53530.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ACM-8RF: Relay module provides 8 Form-C 5.0 amp relays. ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the MS-9200UDLS Rev 3, see the following data sheets (doc- ument numbers) ACM-8RF (DF-51555), ACS/ACMSeries (DF- 52378), LDM Series (DF-5 1384), LCD-80F (DF-52 185). LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. 5D355R: Addressable remote test capable detector for use with D355PL or DNR(W) duct smoke detector housings. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile, heat detector with rate-of- rise option. H355HT: Fixed high-temperature detector that activates at 190F/88C. AD355(A): Low-profile, intelligent, "Adapt' multi-sensor detec- tor (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D355PL: Innovair Flex low-flow non-relay duct-detector hous- ing. 5D355R included. DNRW: Innovair Flex low-flow non-relay duct-detector hous- ing, with NEMA-4 rating. Watertight. (Order 5D355R sepa- rately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. DF-60601:A1 • 12/07/2010 - Page 3 of 6 MS-9200UDLS I Remote ACC-25/50 I Fire Alarm Microphone Audio Command Control Panel 0. Center I 0 0 - Cn I I SPR Speaker SPC Photo Detector Series Spear , LCD-80F SPS Adapt Detector Series - Speaker/Strobe - ANN-80 H355/H355R/H355H1 Heat Detector P2R E iji Strobe MDF-300 Dual Monitor Module -. - P2R Strobe Power Supply 5D3551 FCPS-24F56 FCPS-24FS8 Photo/Thermal -: 1111- .Strobe MMF-300 Monitor Module iVIUiLIIYIOUUieS CRF-300-6 Six-Relay Control Module CMF-300-6 Six-Circuit Supervised Control Module ED • MMF-302-6 Six-Zone Interface Module MMF-300-10 Ten-Input Monitor Module MMF-302 2-Wire Detector Monitor Module - D355PL Beam Detector/ Beam 355 Duct Detector L_ MS-9200UDLS L ADDRESSABLE FIRE ALARM BG-12LXAddressable CONTROL PANEL Manual Pull Station CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0 (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 opera- tion). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a BB- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9200UDLS Rev 3, see the following data sheets (document numbers): AD355 (DF-52324), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-60379), CMF/CRF Series (DF-52 130), CP355 (DF-52383), D355PL (DF- 52398), H355 Series (DF-52385), 1300 (DF-52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), SD355/5D355T (DF-52384). 2) Legacy 300 Series detection devices such as the CP300/CP350, SD300(T)/ 5D350(7) and older modules such as the M300, M301, M302, C304, and BG- IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard LiteSpeed protocol. Please consult factory for further information on previous 300 Series devices. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. Page 4016— DF-60601 Al • 12/07/2010 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits.......................................1 Addressable device capacity ..........................................198 Programmable software zones.........................................99 ACS Annunciators ............................................................32 ANN-bus devices..............................................................16 Electrical Specifications AC Power: MS-9200UDLS Rev 3:120 VAC, 60 Hz, 3.0 amps. MS-9200UDLS Rev 3E: 240 VAC, 5 0 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batteries require an external battery charger such as the CHG- 75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) for a total of four Style Y (Class B) or with an optional ZNAC-92 module con- verts to four Style Z (Class A) NACs. Maximum signaling cur- rent per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to panel documentation and Fire-Lite Device Compatibility Docu- ment for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each output. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F. NFPA Standards The MS-9200UDLS Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9200UDLS Rev 3 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S624 FM approved CSFM: 7165-0075:0208 MEA: 120-06-E For ULC-listed version, see DF-60599. FireLite® Alarms® is a registered trademark of Honeywell International Inc. Wheelock® is a registered trademark of and ExcederTM is a trademark of Cooper Notification. ©2010 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I S0 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & NIANUFAMRING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6of6—DF-60601:A1 • 12/07/2010 July 15, 2004 DF-51131 -300 FlreLITeALarrns MR Series Control Relays www.firelite.com Section: Miscellaneous GENERAL MEA The Air Products & Controls MR Series Multivoltage Con- 7392E 7392E, Vol. III trol Relays offer SPDT or DPDT 10-amp contacts which (MR-101/CorCR, (MR-201/CorCR, may be operated by one of four input control voltages. A MR-11 04/C 01CR) MR-204/C or CR) single relay may be energized from a voltage source of 24 LISTED ate input terminals. (MR-101/CR, State Fire VDC, 24 VAC, 115 VAC, or 230 VAC by wiring to appropri- S3403 California MR-104/CR, Each relay contains a red light-emitting diode (LED) which MR-201lcR, 7300-1004:101 indicates the relay coil is energized. Relays may be MR-204/CR) (MR-101/CR,MR-104ICR, "snapped apart" from a standard four-module assembly MR-201/CR,MR-204/CR) and used independently. These devices are ideal for applications where local con- tacts are required for system status, remote contacts for control of electrical loads and general purpose switching. CSI I8/ They are suitable for use with HVAC, Temperature Con- CS733 trol, Fire Alarm, Security, Energy Management, and Light- (MR-104 and 0 0 ing Control Systems. MR-204 The Air Products & Controls MR-199 Heavy Duty Power Series ONLY) Relays are designed for control applications where 30- amp DPDT contacts are required. The 24 VDC and 120 ON VAC relays are mounted in a rugged steel enclosure. MR SERIES FEATURES (Excluding MR-199 Series) Each relay position may be energized from one of four input control voltages. Each relay position contains a red LED which illuminates o o when the coil is energized. This provides a timesaving convenience when checking an installed system, no me- tering is required. L • Single, dual, or triple relay modules may be "snapped apart" from a standard four-position master. The MR-WI/CR SPDT or DPDT relays available. Available in dust-proof metal enclosures (with gray plastic cover on MR-101/CR and MR-201/CR) with LED view- ing port. 0 0 Red enclosure available on some models. Track mounting hardware to facilitate installation in stan- dard cabinets. UL recognized relays rated at 10,000,000 mechanical l operations. . 0 0 The MR-I04/CR Fire-Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific IS0 9001 IIIII applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toil-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-51131 07115/04 - Page 1 012 PRODUCT SPECIFICATIONS FOR MULTIVOLTAGE CONTROL RELAYS Power requirements: MR-101 Position is rated at 0.015 amps (15 milliamps) @ 24 VAC, 24 VDC, 115 VAC, 230 VAC. MR-201 Position is rated at 0.035 amps (35 milliamps) @ 24 VAC, 24 VDC, 115 VAC, 230 VAC. Relays: All relays are UL recognized components. NOTE: Only models with enclosures ("C" suffix) are UL listed as- semblies (excludes MR-199X-13C and MR-199X-14C). Enclosure: 18 gauge CRS, plated with 1/2 conduit knock- outs (top and bottom). The MR-101/CR and MR-201/CR include a metal backbox with durable plastic cover. Contact rating: 10.0 A @ 115 VAC resistive. Ambient temperature: -50°C to +85°C (-50°F to +185°F), Dimensions: MR-1011T and MR-2011T are 3.0° (82 mm) H x 2.125" (54 mm) Wx 1.5" (38.1 mm) D. MR-104/T and MR-204/T are 3.0 (82 mm) H x 8.5 (215 mm) Wx 1.5' (38.1 mm)D. MR-IOIICR and MR-20IICR are 6.125' (130.2 mm) H x 3.25" (82 mm) W x 2.5° (63.5 mm) D. MR-104/CR and MR-204/CR are 6.125" (130.2 mm) H x 9.5" (241.3 mm) W x 2.5" (63.5 mm) D. PRODUCT SPECIFICATIONS FOR HEAVY-DUTY POWER RELAYS Contact arrangement: DPDT standard. Contact rating: 30 Amps @ 240 VAC; 20 Amps @ 277 VAC; 2 HP @ 250 VAC. Coil power: MR-199X-13 is rated at 24 VDC @ 85 mA. MR-199X-14 is rated at 120 VAC @ 85 mA. Temperature range: -30°C to +50°C (-22°F to +122'F). For MR-199X-13: -55°C to +80°C (-67°F to + 176°F). For MR-199X-14: -55°C to +45°C (-67°F to +113°F). Dimensions: MR-199X-13 and MR-199X-14 is 3.13(79.4 mm) high x 2.5" (63.5 mm) wide x 2.31" (58.7 mm) deep. MR-199X-13C and MR-199X-14C is 5.31" (134.9 mm) high x 3.38" (85.9 mm) wide x 3.13" (96.8 mm) deep. PRODUCT LINE INFORMATION Model Description MR-1011T Single SPDT Relay with LED and track- mounting hardware (UL recognized). MR-I0I/CR Single SPDT Relay with LED, mounted in metal backbox with red plastic cover (UL listed). MR-1041T Four-Position SPDT Relay with LEDs and track-mounting hardware (UL recognized). MR-I04/CR Four-Position SPDT Relay with LEDs, mounted in a metal backbox with a red cover (UL listed). MR-201/T Single DPDT Relay with LED and track- mounting hardware (UL recognized). MR-2011CR Single DPDT Relay with LED, mounted in metal backbox with red plastic cover (UL listed). MR-204/T Four-Position DPDT Relay with LEDs and track-mounting hardware (UL recognized). MR-204/CR Four-Position DPDT Relay with LEDs, mounted in a metal enclosure with red cover (UL listed). MR-199X-13 Heavy-duty DPDT Relay only, 24 VDC coil input (UL recognized). MR-199X-13C Heavy-duty DPDT Relay, 24 VDC coil in- put, mounted in enclosure (UL recognized). MR-199X-14 Heavy-duty DPDT Relay only, 120 VAC coil input (UL recognized). MR-199X-14C Heavy-duty DPDT Relay, 120 VAC coil in- put, mounted in enclosure (UL recognized). MR SERIES RELAYS MODEL NUMBER COIL VOLTAGE CONTACTS MOUNTING LISTINGS - 24 VDC - 24 VAC - 120 VAC - 230 VAC SPDT (IOA) DPDT (10A) DPDT (30A) Track Spacer Enclosure UL, CSFM, & MEA ULC MR-101/T X X X 1 X MR-i 01/CR X X X X 1 X X MR-1041T X X X X 4 X X MR-104/CR X X X X 4 X X X MR-201/T X X X X I X MR-201/CR X X X X I X X MR-204rr X X X X 4 X X MR-204/CR X X X X 4 X X X MR-199X-13 X - - I X MR-199X-13C X I X MR-199X-14 X 1 MR-199X-14C - X 1 X Page 2012 - DF-51131 .07/15/04 DF-52121 :C • E-325 MMF-300(A) Series, MDF-300(A) (a Fire urGAtarms Addressable Monitor Modules IJy I %J I VY VVII I -- General Four different monitor modules are available for Fire•Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 40 [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75' (6.985 cm) W x 0.5" (1.270 cm) D used to super- vise a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTM is a communication protocol developed by Fire.Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. designs. MMF-300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterf low devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit MMF-300(A) (Type H) may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DF-52121:C. 10/06/2010 —Page 1014 MMF-301(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems 15 0 1 ADDRESS 0 is 13 2 2 Loo.P TENS ONES I- I O LU o -J -1 LU • -4 0 ca The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3' (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF- 302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-3 02(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 of 4- DF-52121:C • 10/06/2010 MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cults ONLY. Style D (Class A) lDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 l.JA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (00 to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5 (11.43 cm) high x 4 (10.16 cm) wide x 2.125' (5.398 cm) deep. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301 (A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM Approved CSFM: 7300-0075:0185 MEA: 72-01-E Product Line Information NOTE: "A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51309. Architects'/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-52121 :C • 10/06/2010 - Page 3 of 4 e6 I O 'General Notes Amend General Notes to reference 2007 California Codes (see note 2). Design Criteria Add 2007 California Fire Code to list of applicable codes. Project Data Use 2007 CBC construction type. Sheet ASI.O Site Plan u Show all fire hydrants within 600 feet of the project on the site plan. A minimum of one fire hydrant must be located a maximum of 250 feet from all points on the street adjacent to the building. In addition, maximum spacing of fire hydrants is 500 feet. As shown, existing fire hydrant locations do not meet the minimum Fire Code. Show location of proposed sprinkler service connection and fire department connection. Fire department connection should be within 40 feet of a public hydrant located on the same side of the street and on the same side of driveways. Not shown Fire department connection should be located on the same street as the building is addressed. Not shown Sheet A2.1-2.2, A2.4-2.5 Smoke alarms must be installed in each story. Smoke alarms should not be installed in the kitchen due to possibility of false alarm. Smoke alarms must be interconnected within the dwelling unit so that the activation of one alarm will activate all alarms within the unit. Sheet A4.0-4.1 & A5.0-5.1 Exterior Elevations, Building Sections Q Show the lowest level of fire department vehicle access on elevation plans. Class I standpipe system required throughout the building where the floor level of the highest story is located more than 30 feet above the lowest level of the fire department vehicle access. Lowest level fire department access not shown on the plans. 0 Show required address numbers on the elevation plan. Address numbers must face the street on which the building is addressed. Address numbers must be shown on the elevation facing Lincoln Street - west elevation? Project is addressed on Lincoln. Show address number on the site plan as well as on the elevation plan. Sheet A6.0 Door Schedule Door 3 - locking hardware may not be keyed (double keyed deadbolt) from the egress side. Add note to the door schedule - only the main exit door from each retail suite may be equipped with hardware keyed from the egress side if the locking device is readily distinguishable as being locked and there is a sign above the door stating "This door to remain unlocked when building is occupied". 04/05/2011 10:00 FAX 3236807504 Bear Cntraiors In c. I40002/0006 I FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by 11w yt.m ln5tallatlon eontrscto,1 at the time of system ecceptence and approval. 1, PROTECTED PROPERTY INFORMATION Nwno of propArty: OstcfldO Technologies_lne Addresa 62l Yairow Drive, Carlsbad, CA 92009 I)amrlption of property: Conujierciel Offices Occuxuicy type: Nome of property reprssentAtiw - ••• - _______________________ Addro:._.._-.- ..................- Pone:_. Pw: •. E-mail: . - Authority having jurisdiction over Lire Prevention Division, Cy ufCarlsb&4j635 Faraday Phone: (760)602-46 FAX: S760) 6028561 E-mail: FIRE ALARM SYSTEM INSTALLATION, SERVICE, AND TESTING INFORMATION Installation contractor for this equipment: Delta Fire Protection Address: ,7356 Fulton Avenue, North Hollywood, CA 91605 Phone- _(81.8) 7647990 F*,r:(818)7647852 Service organization for rhie equipncnt: Delta Fire Pruoc(ion Address: 7356 Fultoit Avcciuc, North Hollywood, CA 91605 - -. - ........ Phone; (818)764-7990 paw, (R Is) _764-7852 E-mail: Locatinn of ne built drwiga; l)elta Fire Protection .- Location of Mstorical test reports; Location of system operation and maintenance manuals: Del In Fire Protection A contract for test and inspoction in accordniwe with NFPA standarda in in effect os of -- -- Contru4.,d testing company; Delta Firy Protection Addrwei; 7356 Fulton Avenue, North Hollywood, CA 91605 -- Phone: 18) 71,4-7990 Fax: (818) 7647852 - E-mail: Contract expires; IoLl!!_.. Contract number: -- 'requency of rouUne inspections: .1 111l TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter tof'erence of SyLom Type: Fire Lite M89200 Name of organization receiving alarm signals with phone auxibera (if appLteabk);. Alarm: ADT .. - .- .......Phone; () 2382666 - ..... Supervisory, ADT Phone: (888) 23826__ Trouble: ADT - Phone; !32666._._________ Entity to which alarms are riitrunamtted: .._ ...... . Phone: -- Method of rt.ru,ismission of sierras to that o'gnnizhtion or locatthn:_._....- APP AS SUBUTTED cA REPA rt ~, A! T T Is IA 04/05/2011 10:00 FAX 3236607504 Bear Cpntraçtors Inc. lj0003/0006 TYPE OF FIRE ALARM SYSTEM OR SERVICE (continued) 1t'Chapt.e:t 8, itute the means Of traue.IniwiuT1 from the protected prumieea to the xntral station: U Thgital alarm con mtuzitor U McCulloh CI Multiplex CI 2-way radio U 1-way radio P N/A If Ch&pLer 9, note the typo of connection: U Local eiergy U Shunt III N/A 3.1 System Software Operating syeIen (oxecciliw#) software rcvieiurt lavel: Sila-apecific sot'twure revision date: . Revision 'omplotd by:....... -. . -- SIGNALING LINE CIRCUITS Ch4racturisiica of sign-dUng line crvuitR connected to this SyRti?n (scc NFPA 72, Thhla fl. 0.1), It Quo ty:_.. -- _____ Style, .! cii ea: S. ALARM-INITIATING DEVICES AND CIRCUITS (Jhunwteristics of initiating device circuits connected to thiR Rystcln (see NFPA 72, Table 6.5) Quantity: 5 - - Style:. ._ - Claea:_ 6.1 Manual initiating Devices 5.1.1 Manual Pull Statlona Number of münu.ul pull stations:. Type of devices: 14 Addrssahla CI Conventional U Coded U Transmitthr J N/A .2 Automatic Initiating Devices 5.2.1 Anet Smoke Detectors Number of sinolw deectora: TYPO 2 Completeares U PrI.ial area U Nunreqnired partial 05011 U N/A Type of devices: 2 Addruueablo U ConvenLirnaI U Coded U Transtaitter U N/A Type of smoke detector sensing technology: U Innjatiou 2 Photoelectric '6.2.2 Duct Smoke Detectors Numhr of duct smoke dAter.tor$; Type of coverage: Type of devices: 2 Addriesablc U Conventional U Coded U Transmitter CI N/A Type of smoke detector sensing technology: Utonizatiun 2 Photoelectric 5.2.5 Heat 14eotw Number of heat del.ecl.nrs! _.., Typo qf coverage; CI Complete erea 2 Partial sxea C] Nonrequired partial area U N/A Type of devicee: U Addressable U Conventional I] Coded U Tranamjtth, U N/A 5.2.4 Sprinkler Watarfiow Dataetore Number of waterflow detectors: 4) rypo of devices 2 Adtlressahlo C] Conventions] U Coded C] Tmnsnüttar U N/A 6.2.5 Alarm Veriflvution Number of devices tiubject to alarm 'vwifivation: ________ Alarm verificatiou on this system is; U Enabled 6 Disabled U Sat for ______ 5ccflnd8 04/05/2011 10:00 FAX 3238807504 Bear Cpntracbtors Inc. IJ0004/0006 SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUITS 6.1 Sprinkler System Number of vdve rnipervlsory Hwitehes:._. ..... Type ut'devices: 0 Addressubh, 0 ConvntionaI ci Coded U Transmitter ci N/A 0.2 Fire Pump Type of fire pump 0 Electric U Diesel Typo of fire pump eupervioi-y dvcee: ci Addreeeahle Li Conventional Cl Coded 0 Trensmitter tl N/A Fire Pump FunetinnR Supurvied ci Firt pump power ci Fire pump running U Pfre pump ptimije reversal Cl Selector awitch not in auth Cl BnginA or control panel trouble ci Low fuel Other: -. •. ______________- _______________ - ______________ 6.3 Engine-Driven Generator Type Ot'geflAretor supervianrydevices: U Addreeaahlc U Convenliunal U Coded ci Transmitter 10 N/A Cl Engine or control panel trouhlA Ci Generator running ci Selector switch not in auto 0 Low fuel flthrn. ANNUNCIATORS 7.1 Annunciator 1 • LocAl LI Remote TypH: IJ Addruable Cl Directory U Graphie 7.2 Annunciator 2 IJ Local ci lWmote Type: Cl Addtosab1e U Directory 1] Graphlo 7.3 Annunciator 3 Cl Local Cl Remote Type: U Addresab1e Li Directory Cl Graphic N/A Location: ... - N/A Location: _ ...... ••.. .. - 4 N/A Location: 8. ALARM NOTIFICATION DEVICES AND CIRCUITS 8.1 Emergency Voice Alarm Service Number ofi,i1v voice alarm chazmcl,. ______- Number of multiple voice alarm c.bnnnele: Number of speakers; -. -. . . - Number of speaker zones: 8.2 Telephone Jacks Number of teIephonu jacks mate hAd; -, . Number Number of tIphnie hundeets stored on site;-. - Typo of telephone syikzzt metalled: ci ElHctrieally powered Cl Souiid powered LJ N/A 8.3 Nonvoice Audible System Characei;is • of notifi'ofwii device c1rcvi5 coni'cted to thin Rystern (ree NF/.'A 724bk 64): Quentit ... .. Style -.,...... CIaes:2......... 04/05/2011 10:00 FAX 3236607504 Bear Contraçtors Inc. I210005/0006 ALARM NOTIFICATION DEVICES AND CIRCUITS (continued) . 8.4 Types and Quantities of Nonvoice Notification Appilan tailed Bells:. .....With visual device: Horn X . -- With visual device Chimes: With visual device- Bells: With visual device: Visual devices without audibk dovic.3 . (hher(describe): . . - .....7......._. ......... EMERGENCY CONTROL FUNCTIONS ACTIVATED D Hold..opoa door zubaalng daviceii e Smoki msngement or smoke cntroI I Door unlocking U Elevator Tfw.all W Other SYSTEM POWER SUPPLY 10.1 Primary Power Nominal voltage 120v Amps 20 Ovrcuni%nt protection firsaker Ampm 20 MEZZANINE Location (of primary supply panelboard):... -. Disconnecting means location: MEZZANINE 10.2 Secondary Power Location: Firc Alarm Panel Batteries 24 Nominal voltage: . .-- Current rating:_24 Number of standby battcrlee: 2 . Amp hour rating: 10 Location of emergency generator: Rear of liulldiiuii Location of fuel storage: eur of BL!cig Calculated capacity at' secondary power to drive the syetm In standby mode; .. _ In alarm mode: .. RECORD OF SYSTEM INSTALLATION Fill out after all installation r.r complete and wiring/,as b&rn chucked for openi, xhorts round fayslts, and improper branch mit. but before conducting operation1 ocnptancc tests. The aymLexii has been installed in accordance with Chu fvfluwing NFPA standards: (Note any or all that apply.) IVFFA 72 U NJ"L'A 70, National Electrical Cock, Article 760 V MnuThoturer's published instructivils U Other (please speoify: Carlsbad Fire Departitucul System deviations from referenced NFPA standards: Signed:_ .. - me:_!ry (ilcibctniaui flato: QjL01t2OlI Organization; Delta k1re Protection - -- TiLls; - (81R) 764-7990 12. RECORD OF SYSTEM OPERATION All peratimal features and funvthms of this system were tested by or in the presence of the signer shown below, on the date showit bsluw, and were found to be operating properly in accordance with the requirements of * NPPA 72 U NFPA 70, National Electrical Code, Article 760 V. Mu&l,urer's published instnwtions U Other (please speeff'): U Documentation in eccordantxm with Inspection and Teeting Form (Figure 10.6.2.3) is attached Signed: . .. Printed Glelberman .__ Date: 1/2011 Organization: Delta Fire Protection Title: _______ . ,.._________ PI1OIe: (818)764-7990_— 04/05/2011 10:01 FAX 3238801504 Bear Cpntracors Inc. IJ0006/0006 13. CERTIFICATIONS AND APPROVALS 13.1 Syetam lntallatIon Contractor This gystem as epcciilcd herein has bee installed and Lcecthd nccordiag to all NFPA standards iithd hrein, Signed: . - ._ Printed name: Barry Cleihermar. - . . . Date:_______ OrganiaoUvn:_Delta Fire Protection Contractor - . 13.2 System Service Contractor This sYstem as &ipecified herein hao been installed and teMed according to all NFPA mtands#rdA cited horei. flrrw (lpihp,inn,i - ... Prittccj name: ..L_ Date: - ....... Organization: Delta Fire Protection Title, Contractor - .. Phune: 764-7999 -- 13.3 Central Station Thin system as apc1fied herein will he monitored according to all NFPA standards cited herein. Signed: Organt.utivn: - Printed name- . - Title: 13.4 Property Repre;entative I aniept this eyetem as having been Installed and tested to its specifications and all N i"PA Standardo cited herein. - Sied: - Pnntednan,e: John Gow - ganation Title: Phone: (951)741-9922 - 13.5 Authority Having Jurisdiction I have witnessed a Rati8factw-y acceptance test of this system and find it to be inetallM and operating properly in accordance with ite approved plans and speCifieetioiis, its approved epquencc of operations, and with all NFPA standards ei,d herein. Signed: Pthlted name: L Dato:./14. Organiza on:_ sbid F re Depart. Phone:7e-gcS 04/05/2011 10:01 FAX 3238607504 Bear CQntractors Inc. 1j0001/0001 13. CERTIFICA110NS AND APPROVALS 13.1 System Installation Contraotor Thi5 ystem as specified heicthi litw been installed and tested according to all NJ!PA standards cited herein. Signed: —Y .._ Printed nanie: Barry (leiberinaii Organization; Delta lire PPPPPPPPPP - Title.Contractor (818) 764-799ft 13.2 System Service Contractor This syeem ne epeciltccl herein has been installed and tested according to all N.FPA elandards cited herein. Slgncd; -. ________ Printed name; Barry Cleiberman flute: - Organizatlnn: Velto Fire Protection Title:________________________ Phone: (81 S) 764.7990 13.3 Central Station This systoni w specified herein will be monitored acerdiig to all NFPA standards cited heroin. Signed: ._ .. Printed Llama: - Date: Organization:. Title: --......... Phont........ 13.4 Property R.pr.søntative I accept this system as having been installed and tested to it,R Hpsciftcatione &ud all NFPA standards cited herein. Signed: - Printed name: -- John Cow Data: __________ Organizatien; -. - Title:_ Phone. (951)741-9022 135 Authority Having Jurid!ctIon I have witnessed a satisfactory nevipLanca NO. of this system and find It to be inatnlkd and operating properly in accordance with itis approved pious and specifications, its approved sequenee of operations, and with all N PPA etazidarcle ted herein. ev Signed:.Z- . . Printed name: O Orgazuzation: C ilsbad Firy pi. - Phone: 740- %S2 t'0c0