Loading...
HomeMy WebLinkAbout6269 EL FUERTE ST; ; FA110058; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA110058 Job Address: 6269 EL FUERTE ST Permit Type: FALARM Parcel No: 2131221400 Lot #: 0 Reference No.: Status: APPROVED Applied 8/17/2011 Approved: 8/17/2011 Issued: 8/17/2011 PC #: Inspector: Project Title: PACIFIC RIDGE HS TI ADD TO DIVIDED SPACE ON 2ND FL CREATING TWO OFFICES Applicant: HIDDEN EYE SECURITY 42320 VIA NORTADA TEMECULA, CA Owner: P R S ACQUISITION&CONSTRUCTION L LC 6269 EL FUERTE ST CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 125 0 125 0 FAL1cô . Fire alarm system cut sheets & California State Fire Marshal Listing sheets for: 6369 EL FUERTE STREET CARLSBAD, CA 92009 REVISION #3 ON 07-27-11 2ND FLOOR OFFICE TENANT IMPROVEMENTS Cooterccfl And eeotithfl AUum 2oavceo 42320 VIA NORTADA TEMECULA, CA 92590 (951)816-3838 API I~EP.4 ,.,. SUBWTTED dARLISBAD FIRE DEPARNT Service Center No I Underwriters Laboratories Inc. ® Applicant ID No: 983340-001 Northbrook, IL San Jose, CA Expire : 31-MAR-2012 Melville, NY A not-for-profit organization dedicated to public safety and committed to quality service CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is includec by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Me rk in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requireME nts is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certifi ate Verification Service. This Certificate does not apply in any way to the communication channel between he protected property and any facility that monitors signals from the protected property unless the use of a U listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: TEMECULA, CA (TEMECULA) Alarm Service Company: (983340-001) Service Center (983340-001) H E S H E S 42320 VIA NORTADA 42320 VIA NOR ADA TEMECULA CA 92590 TEMECULA CA 92590 The Alarm Service Company is Listed in the following Certificate Service Categories: File -Vol No. CCN Listing Category S8057 -1 UUFX [Signal and Fire Alarm Equipment and Servttation ces] (Protective Signaling Services) Central ***THIS CERTIFICATE EXPIRES ON 31-MAR-2012 *** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" 2-APR-2O1 I 0 2008 UL Form CS-CC I Addressable Photoelectric Smoke Detector & Photoelectric Smoke with Thermal ®MEA 225-02-E Vol. V IDP-Photo (Base Not Included) Compatibility The IDP-Photo and IDP-Photo-T are compatible with the following lDP-series detector bases: IDP-6AB 6" Mounting Base SSB501 4" Mounting Base* SSB224B1 6" Isolator Base* SSB224RB 6" Relay Base* SSB50IBHT 6" Temporal Sounder Base* The IDP-Photo and lDP-Photo-T are compatible with the following FACPs: IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel * For ordering purposes, an SS has been added to the System Sensor part numbers. Example—System Sensor PN for SSB501 is B501. Farenhyt IDP-Photo & IDP-Photo-T The IDP-Photo is a photoelectric smoke detector and the lDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the lDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the IDP-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3601 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (PN SSRA400Z; System Sensor@ PN RA400Z) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed Installation The IDP-Photo and IDP-Photo-T plug into a compatible lDP-series detector base. SILENT Meridian Circle Maple Grove, Mn 55369-4927 Maple KNIGHT D 763493-6455 1-800-328-0103 C Fax: 763493-6475 by Honeywell www.farenhyt.com P/N 350280 Rev C, 08/15/06 Copyright © 2006 Silent Knight Wiring IDP-Series Detector Mounting Bases Specifications* Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 5.2 oz. (147 g) Electrical Operating Voltage: 15-32 VDC Standby Current: 250 pA @ 24 VDC (no communication; LED off) 300 pA @ 24 VDC (one communication every 5 sec with LED enabled) Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature IDP-Photo: 32° - 120°F (0°C - 49°C) lDP-Photo-T: 320 - 100°F (0°C - 38°C) Humidity: 10% - 93% non-condensing Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F (57°C) Ordering Information IDP-Photo Photoelectric Smoke Detector IDP-Photo-T Photoelectric Smoke Detector with Thermal (135('F) Accessoriest SSRA400Z Remote LED Annunciator. SSRMK400 Recessed Mounting Kit. Provides low profile for use with SSB501. SSXR2B Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the SST55-127-000. SSM02-04-01 Detector Test Magnet. SSM02-09-00 Test Magnet with Telescoping Handle. SSXP-4 Extension Pole for SSXR2B. Extends from 5-15 ft. SST55-127-000 Detector Removal Head. SSBCK-200B Black Detector Kit. For IDP-series detectors. * Unless otherwise noted, specifications apply to lDP-Photo and Velocity: 0 - 4000 fpm (0 - 20 m/sec) IDP-Photo-T. IDP-Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal t For ordering purposes, an SS has been added to the System Sensor part numbers. Example—System Sensor PN for SSB501 is B501. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications NNNN KNIGHT or anticipate all requirements. All specifications are subject to change without notice. e For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple by Honeywell Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models lDP-PHOTO, lDPPHOTOR*, IDP-PHOTO-T, IDP-ACCLIMATE, 5K-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models lDP- PHOTO and lDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing Nc. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. C2-':1-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This Iis:ing is riot an endorsement or recommendation of the item listed. This listing should not be used to verfy correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (§ LISTING No. 7300-0559:0159 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model IDP-6AB detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as detector base for use with separately listed compatible detectors. XLF: 7300-0028:0173 II 07-20-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division