HomeMy WebLinkAbout6269 EL FUERTE ST; ; FA140132; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA140132 Job Address: 6269 EL FUERTE ST Status: ISSUED Permit Type: FALARM Applied 9/5/2014 Parcel No: 2131221700 Approved: 9/18/2014 Lot #: 0 Reference No.: Issued: 9/18/2014 PC #: Inspector: Project Title: PACIFIC RIDGE ARTS INSTALL A NEW FIRE ALARM SLC EXTENDERS IN ARTS BUILDINGS TO EXTEND EXISTING FACP (IN HIGH SCHOOL MDF). SYSTEM TO MONITOR SMOKE DETECTORS, HEAT DETECTORS AND PULL STATIONS. INTALL HORN/STROBES THRU-OUT FOR NOTIFICATION OF OCCUPANTS. SYSTEM TO BE AUTOMATIC (SMOKE DETECTORS) FIRE ALARM SYSTEM IS MONITORED BY CENTRAL STATION. Applicant: RIVER FIRE & SECURITY INC. 8920 ACTIVITY RD STEJ SAN DIEGO, CA 858-752-6250 858-752-6260 Owner: PACIFIC RIDGE SCHOOL ATTN:PHILIP HITCH 6269 EL FUERTE ST CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 556 0 556 0 Parsley Consulting Plan Review Comments for Pacific Ridge Middle School and Arts Building Alarm System page 2 of 2 1) The requirements contained in NFPA 72, section 7.7.2 must be verified, including: A documentation cabinet installed at an approved location [7.7.2.1] Record documentation is required to be stored in that cabinet [7.7.2.2] Indication on the control unit as to the cabinet location should be provided if the cabinet is not at the control unit. [7.7.2.3] Cabinet should be prominently labeled "SYSTEM RECORD DOCUMENTS" [7.7.2.4] Contents of the cabinet are to be accessible only by authorized personnel. [7.7.2.5] Cabinet should include copies of record of completion, record of inspection and testing, and risk analysis. [7.8.2] 2) The only project specific comment is that notification appliance V1-1 in the second floor classroom 1 of the Middle School Arts Building does not appear to be connected to the alarm system. Field verify that this device is indeed connected, and that the appropriate system address has been programed. No resubmittal is required. We strongly recommend the following operational tests be performed once the system installation has been completed. A "power off' test, where the normal power supply is shut off, and the system is left to function on battery power alone for a period of 24 hours, at which time the system should still be functioning and operational. At the end of the end of the above test, prior to the primary power being restored, the system should be placed in an "alarm" condition for a period of not less than five minutes, during which time all notification appliances, including the off-station notification, are to function as designed. Once the two prior tests have been completed, the current level in the batteries should be checked, the primary power restored, and at the end of 48 hours the current level checked again to verify that the charging function of the panel is both operational, and able to recharge the batteries within the time period specified by NFPA-72. Once the test in item "c" has been completed, one of the leads to the battery should be disconnected, to determine that the system will provide notification of an "off-normal" power condition to the monitoring company. File: c :\Users\Ken\Documents\Rev2 14343.1 .Docx S PACIFIC RIDGE MIDDLE SCHOOL AND ARTS BUILDING 6269 EL FUERTE ST. CARLSBAD, CA. 92009 Fire Alarm Submittal 8/22/14 '- \ ii" 01 IN ::------ \'-. Submitted By: RIVER FIRE & SECURITY 8920 ACTIVITY RD. # J San Diego, California 92126 License#896646 FA FA140132 S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0135 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5820, 5820XL, IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterliow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, lFP-1000 : Control Units 058200P: Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor InteIIiknight 5820: Enclosure 5860/5860R/RA-1000: Annunciator 5496: Power Module 5824 : Serial/Parallel Interface 5895/5895XLIRPS-1 000: Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SD500-ANM : Addressable Notification Module SD500-LIM : Line Isolation Module 5D505-61B: Isolation Base SD-500 SDM : Smoke Detector Module RA-100: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB: Battery Cabinet 5897, 5898 : Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E(CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SILENT Farenhyt by Honeywell SLC Expander Signaling Line Circuit Expander Agency Listings 5815XL MEA 429-92-E Vol VI The 5815XL is a signaling line circuit (SLC) expander for use APPROVED with the Farenhyt IFP-1000, IFP-1000ECS and IFP-2000 analog/addressable fire alarm control panel (FACP). Use the 0 0 oczz - 5815XL to add more SLC devices of the same protocol to the u IFP-1000/ECS or IFP-2000 control panel. , J° The 5815XL supports the same number of devices and SLC 00 device types that are supported by the control panel. A o 00 maximum of seven 5815XLs can be used with the IFP- 00 I L 1000/ECS FACP. A maximum of 63 5815XLs can be used on an IFP-2000 panel, but the total SLC device count is limited to 636. 3 U The 5815XL communicates with the FACP via an RS 485 system bus. A green LED on the 5815XL board blinks to indicate good communication. If an addressable device on a 5815XL 5815XL fails, the loop communicates the failure to the IFP- 1000 and continues to operate normally. Installation Features The 5815XL can be mounted on standoffs Adds support for up to 159 IDP detectors and 159 lDP located in the IFP-1000, IFP-1000ECS, IFP- modules or 127 SD devices to the IFP-2000 system. 2000 or RPS-1000 cabinet or in the 5815RMK Adds support for up to 99 IDP detectors and 99 IDP modules remote mounting kit. All control panel or 127 SD devices for the IFP-1 000/ECS system. Communicates with the FACP via RS 485 system bus mounting options allow you to install two 5815XLs per cabinet. LED indicates good communication House up to two 5815XLs in the IFP-1000 cabinet, IFP-2000 Compatibility cabinet, RIPS-1 000 cabinet, or one 5815XL in the 5815RMK The 5815XL is compatible with the remote mounting kit IFP-1000, IFP-1000ECS and lFP-2000 FACP. • SLC wiring used standard wire. Twisted pair or shield cable The 5815XL supports multiple device types of are not required the same protocol, either SD or IDP. You UL 864 listed, complies with NFPA 72 and 101 cannot mix SD and IDP devices on a 5815XL. CSFM approved MEA FM approved P/N 350211 Rev F Copyright © 2013 Honeywell International Inc. FleXpUtTM is a Trademark of Silent Knight Jumpstart® is a Registered Trademark of Silent Knight Ii. made' 5815T Model 5alSXLV SLC Loop SLC Loop 2 SLC Loop 3 FACP Cabinet FACP 5815XL 23 22 21 20 19 18 17 161 Sc- S+ SC- S4 I + A B ± A OUT , j — Y Y Used in f., To SLC S U.d lass A configurations lFP-1 000 connection to 5815XL Control Panel 8 ggembly Ii t -l'i I I HLS7 Otr taUk 01St IOOS3 5*3501 03505333301 F71 r7r_9z pq IFP-2000 connection to 5815XL Specifications Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) H OI0I eight: 4.2' (10.7 cm) Width: 4.8' (12.2 cm) Shipping Weight: 5.6 oz (159 g) RPS-1 000 Physical (Optional Accessory) Height: 26" (66 cm) Width: 16" (40 cm) Depth: 4.7" (11.8 cm) Shipping Weight: 28.8 lbs (13.1 kg) 5815RMK Physical (Optional Accessory) Height: 10.2" (25.9 cm) Width: 10.4" (26.4 cm) Depth: 3" (7.6 cm) Shipping Weight: 1.2 oz (37g) Humidity: 10% - 93% non-condensing Approvals NFPA13, NFPA15, NFPA16, NFPA7O, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved Ordering Information 5815XL Signaling Line Circuit Expander. System Capacity Accessories lFP-1000/ECS FACP supports seven 5815XLs RPS-1000 IFP-2000 FACP supports 63 5815XLs (but a maximum of 636 SLC devices per system) 5815RMK 5815XL Capacity: 127 SD addressable devices for lFP-1000/ECS & IFP-2000 VIP-5815MK 159 lDP detectors and 159 lDP modules for IFP-2000 99 lDP detectors and 99 IDP modules for the IFP-1 000/ECS Electrical Standby & Alarm Current: 55 mA max - 125 mA with maximum number of devices installed on 5815XL) Intelligent Power Module. Cabinet holds two 5815XLs. Remote Mounting Kit. Cabinet holds two 5815XLs. Mounting Kit. Mounting kit installs in VIP-series cabinets and holds two 5815XLs. SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or D - KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 - by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446- 6444. www.farenhyt.com Made in the U.S.A. Specifications Physical Height: 7.4" (18.8 cm) Width: 9.1" (23.1 cm) Depth: 1.5' (3.8 cm) Shipping Weight: 2.8 lbs (1.3 kg) Color RA-1000R: Red RA-1000: Gray Electrical Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Ordering Information Approvals NFPA72 UL Listed; CSFM 7170-0559:135; MEA 429-92-E Vol. IX; FM Approved RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per tine. Red. RA-1000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. IFP-1 000 FACP . _ - r1000 —'oOo J J D° ooc RA-1000 RA-1000 I I .1 4_Au a RA-1000 Up to 8 RA-1 000 per system 80-character backlit LCD display (4 lines with 20 characters each) Wiring lengths up to 6000 ft. from the control panel Accessories Wiring Distance: 6,000 max. from FACP (depending on wire 58601R Red Trim Ring. For surface mounting. gauge and number of devices on the SBUS) 58601G Gray Trim Ring. For surface mounting. Max Per System: 8 Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or D KNIGHT anticipate all requirements. All specifications are subject to change without notice. For -. more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Made Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com e in the U.S.A. Programmable for NACs, Auxilary Power, or Conventional Initiation Input Circuits (2- or 4-wire) RPS-1000-1 RPS-1000-2 - - , Programmable for NACs, 0 0 -- r . Auxilary Power, or I RAI000 Programmable for NACs, o Conventional Initiation -n Input Circuits (2- or 4-wire) CO Auxilary Power, or CO Conventional Initiation Input CA Circuits (2- or 4wire) -, mD cr 111111 I RPS10001 SBUS I RPS10002 SBUS To Next I I I I ;;. Ell :. • __ 58I5XL RA-1000s 5824 5815X1 RA-1000 L...... SIC L..~SLC Devices Devices • Specifications Electrical S Primary AC: 120 VRMS, 50 or 60 Hz, 2.7A, or 240 VRMS 50 or 60 Hz, 1 .4A Total Accessory Load: 6A © 24 VDC Standby Current: 40 mA Alarm Current: 160 mA Flexput Circuits: Notification: 3 amps per circuit (6A system total) Initiation: 100 mA power limited @ 24 VDC Physical Mounting Dimensions: 14.5"W x 24.75"H x 3.9"D (36.8 cm W x 62.9 cm H x 9.8 cm D) Overall Dimensions: 16.1"W x 26.4"H x 4.1"D (40.6 cm W x 67 cm H x 11.8 cm D) Color: Red Environmental 5815XL Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Approvals UL 864 NFPA13, NFPA15, NFPA16, NFPA7O, NFPA72, & NFPA 101 CSFM MEA 429-92-E Vol. IX FM Ordering Information RPS-1 000 Intelligent Distributed Power Module. Specify 120 VAC or 240 VAC operation when ordering. Remote Battery Box Accessory Cabinet. 16"Wx10" Hx6" D (406 mmWx254 mm H x 152 mm D) Remote Battery Box Accessory Cabinet. 20W x 12" H x 7.5" D SLC Expander Module Accessories RBB AB-55 keep our product information up-to-date and accurate. We cannot cover all D SILENT This document is not intended to be used for installation purposes. We try to KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, ____________________ by Honeywell Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A [] Class A Optional Wiring Wiring lOP-Series Detector Mounting Bases Wiring IDP-Series Detector Mounting Bases Specifications* Ordering Information Physical Is Diameter: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) installed in B501 base Electrical Operating Voltage: 15-32 VDC Standby Current: 250 pA @ 24 VDC (no communication; LED off) 300 pA @ 24 VDC (one communication every 5 sec with LED enabled) Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature lDP-Photo: 320 - 120°F (0°C - 49°C) IDP-Photo-T: 320 - 100°F (0°C - 38°C) Humidity: 10% - 93% non-condensing Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F (57°C) Velocity: 0 - 4000 fpm (0 - 20 m/sec) (suitable for installation in ducts) lDP-Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal IDP-Photo Photoelectric Smoke Detector lDP-Photo--T Photoelectric Smoke Detector with Thermal (135°F) lDP-PhotoR Photoelectric smoke detector, remote test capable, for use with DNR (W) duct smoke detector Accessories RA100Z Remote LED Annunciator. XR213 Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the T55-127-000. M02-04-01 Detector Test Magnet. M02-09-00 Test Magnet with Telescoping Handle. XP-4 Extension Pole for XR213. Extends from 5-15 ft. T55-127-000 Detector Removal Head. BCK-200B Black Detector Kit. For lDP-series detectors. * Unless otherwise noted, specifications apply to lDP-Photo and IDP-Photo-T. This document is not intended to be used for installation purposes. We try to keep our . D SILENT product information up-to-date and accurate. We cannot cover all specific applications or -. KNIGHT anticipate all requirements. All specifications are subject to change without notice. For -. more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models IDP-PHOTO, lDPPHOTOR*, IDP-PHOTO-T, IDP-ACCLIMATE, SK-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models IDP- PHOTO and IDP-PHOTOR • are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division S Class A Optional Wiring Wiring IDP-Series Detector Mounting Bases Specifications* lDP-Heat-ROR: Rate-of-rise detection 151F/mm (90C/mm) Physical Height: 2.0" (5.0 cm) Diameter: 4.1' (10.4 cm) Shipping Weight: 4.8 oz (136 g) Electrical Operating Voltage: 15 - 32 VDC Standby Current lDP-Heat: 200 pA @ 24 VDC (no communication; LED off) 300 pA @ 24 VDC (one communication every 5 sec with LED enabled) lDP-Heat-HT & lDP-Heat-ROR: 150 pA @ 24 VDC (no communication; LED off) 200 pA @ 24 VDC (one communication every 5 sec with LED enabled) Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Ordering Information IDP-Heat Fixed Temperature Thermal Detector lDP-Heat-HT Fixed High Temperature Thermal Detector lDP-Heat-ROR Fixed Temperature and Rate-of-Rise Thermal Detector Accessories RA100Z Remote LED Annunciator. XR213 Detector Removal Tool. A removal and replacement tool for lDP plug-in detectors. Includes the T55-127-000. M02-04-00 Replacement Test Magnet. M02-09-00 Test Magnet with Telescoping Handle. XP-4 Extension Pole for XR213. Extends from 5— 15 ft. T55-127-000 Detector Removal Head. BCK-200B Black Detector Kit. For IDP-series detectors. Environmental Operating Temperature * Unless otherwise noted, specifications apply to all IDP IDP-Heat & IDP-Heat-ROR: -40 - 100°F (-20°C - 38°C) thermal detectors. IDP-Heat-HT: 40 - 150°F (-20°C - 66°C) Humidity: 10% - 93% non-condensing Thermal Ratings IDP-Heat: Fixed temperature setpoint 135°F (57°C) lDP-Heat-HT: High temperature heat 135°F - 190°F (57°C - 88°C) This document is not intended to be used for installation purposes. We try to keep our D SILENT product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For BERM more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Made in the U.S.A. 17A CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0559:0147 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike. mcisaachoneywell.com DESIGN: Models lDP-HEAT and SKHEAT* (fixed temperature) lDP-HEAT-ROR,lDP-HEAT-HT, SKHEATROR*, and SKHEATHT*(fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 135°F fixed temperature for Models IDP-HEAT, lDP-HEAT-ROR, SKHEAT* and SKHEATROR* 190°F fixed temperature for Model lDP-HEAT-HT and SK-HEAT-HT INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with *Iistees separately listed compatible base and fire alarm control units. Refer to listee's Installation Instructions Manual for details. XLF: 7270-0028:0196 *Rev. 07-14-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL Oft FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM • LISTING SERVICE LISTING No: 7150-0559:0157 Page 1 of 1 CATEGORY: 7150— FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model IDP-PULL-SA manual pull box. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 09-08-09 fm This listing the test is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S operational Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division TO NEXT DEVICE ANY NUMBER OF ML LISTED CONTACT CLOSURE DEVICES MAY BE USED, DO NOT MIX FIRE ALARM INTIATING SUPERVISORY, OR SECURITY DEVICES ON THE SAME MODULE. FROM PANEL OR PREVIOUS DEVICE MONITOR MODULE ,J CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY in 47K EOL RESISTOR ELR-47K ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED INITIATING DEVICE CIRCUIT (IOC)-NFPA STYLE B POWER LIMITED: 45OpA MAX @I I VDC MAX INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURERS INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style B TO NEXT FROM PANEL OR DEVICE PREVIOUS DEVICE MONITOR ANY NUMBER OF UL LISTED CONTACT MODULE Li CLOSURE DEVICES MAY BE USED. DO NOT MIX FIRE ALARM INTIATINS, SUPERVISORY. CONNECT CT MODULES TO LISTED COMPATIBLE 10 CONTROL PANELS ONLY SECURITY DEVICES ON TI-IS SAME MODULE EOL RESISTOR IS INTERNALAT TERMINALS 8 59 ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED INSTALL CONTACI CLOSURE DEVICES PER MANUFACTURERS INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style D Specifications 550 pA max @ 24 VDC (one communication every Physical 5 sec with EOL <1K) Height: 4.5" (11.4 cm) 5.5 mA (with LED latched on) Width: 4" (10.2 cm) LED Current: 5.5 mA (with LED latched on) Depth: 1.25" (3 cm) End-of-Line Resistance: 47K c Shipping Weight: 6.3 oz (196 g) Initiating Device Circuit Wiring Resistance: 1,500 Q max Electrical SLC Loop Resistance: 40 Q max. Operating Voltage: 15 - 32 VDC Environmental Current Draw (LED on): 5.0 mA max Operating Temperature: 32°F - 120°F (0°C - 49°C) Operating Current (LED flashing): 375 pA Humidity: 10% - 93% non-condensing Standby Current: 400 pA max @ 24 VDC (one communication every 5 sec with 47K EOL) SILENT This document is not intended to be used for installation purposes. We try to keep our ll product information up-to-date and accurate. We cannot cover all specific applications or ____________ KNIGHTI anticipate all requirements. All specifications are subject to change without notice. For Ift______ more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com Made in the U.S.A. 0 CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY. TO NEXT DEVICE FROM PANEL OR PREVIOUS DEVICE If any wiring to Terminals 4-10 is Nonpower limited, The CB500 barrier is required. The CB500 includes a Noripower limited label, which must be placed over the Power Limited terminal information on the name plate label. RELAY CONTROL MODULE oto <:~~ , TOP __ 0 TU © Relay CommJ 2 T9 TI Normally Clos Normally Op TZ Relay Comm 709 T4 Normally Clos T 12 1015 210 TENS O ONES Unused Normally Open 1 NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. Specifications Physical Height: 4.5" (11.4 cm) Width: 4.25" (10.2 cm) Depth: 1.3" (3 cm) Shipping Weight: 6.3 oz (196 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Electrical Operating Voltage: 15 - 32 VDC LED Current: 5.5 mA (with LED latched on) Operating Current: 230 pA (LED flashing) direct poll 255 pA (LED flashing) group poll End-of-Line Resistance: Not used Standby Current: 300 pA max @ 24 VDC (one communication every 5 sec with LED enabled) Relay Contact Ratings Current Rating Max Voltage Load Description Application 3 A 30 VDC Resistive Noncoded 2 A 30 VDC Resistive Coded 0.7 A 70.7 VDC PF = 0.35 Noncoded 0.9 A 125 VAC Resistive Noncoded 0.46 A 30 VDC hR = 20 ms Noncoded 0.5 A 125 VAC PF = 0.75 Noncoded 0.3 A 125 VAC PF = 0.35 Noncoded 2 A 25 VAC PF 0.35 Noncoded S . SIT This document is not intended to be used for installation purposes. We try to keep our EKT'I' ( iL. L £ product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: ,7300 - FIRE ALARMCONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike. mcisaac@honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, lDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, lDP-Zone-6, SK-Zone-6 six zone interface module, lOP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, lOP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP.RELAYMON2 *SKRELAYMON2 with 2 input12 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed compatible fire alarm NOTE: control units. If an external power supply is used for Model SK-Zone-6 and lDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verily correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, .INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range. All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Low LCurrent ii Draw I Strobe Ratings per UL Standard 1971 = Fewer ' I]aI!p] Ii* UL Max 24 VDC /24FWR 12VDC Model Regulated Voltage VDC 15 15/75 30 60 75 185Range 95 110 115 135 150 177 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC __ •E! •• • 24 VDC Model flegulatedVoltage Range 15 15/75 30 60 75 95 110 115 135 150 177 VDC M0.125 HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 ...•Max ==p .•.• 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 177MO. 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 0.186 0.230 0.272 .. .•Max Current*==•••• 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 10.120 S Horn Ratings per UL Anechoic - - - Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 1 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. 1ftHi :\ ~IL 11 I*IJMB Contact Cover Specification & Ordering Information Sync w/ Model Strobe DSM or * 12/24 VDC Mounting Candela Wheelock Power Options Supplies HSR 15/1575/30/75/95/110/135/185 X X UMB** HSW 15/1575/30/75/95/110/135/185 X X UMB** (f HSRC 15/30/60/75/95/115/150/177 X X UMB** HSWC 6 6a 15/30/60175/951115/150/177 X X UMB** STR 1511575130/75/951110/1351185 X X UMB** STW qD 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** S1VVC 15/30/60/75/95/115/150/177 X X UMB** HNR X X UMB** HNW X X UMB** HNRC X X UMB** X HNWC J' X *12 VDC models feature 15 & 15/75 settings Model Legend HN = Horn A =Agent Lettering ST = Strobe (Strobes only) HS = Horn Strobe AL = Alert Lettering C = Ceiling Mount (Strobes only) W = White N =No Lettering R = Red (Strobes only) Example 1: STRC = Strobe, Red, Ceiling Mount \ Example 2: HSR = Horn Strobe, Red, Wall Mount N, Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: STW-AL Strobe, White, Wall Mount, Alert Lettering Exampi'e.\kISR **UMB = Universal Mounting Base , camDle: HSWC NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc., 273 Branchport Ave, Long Branch, NJ 07740 Contact: Raylon Smith (732) 962-7832 Fax (732) 962-7856 Email: raylon.smithcooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC124VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listees name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm øTtk This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Multi-tone Strobe MTWP-2475W-FR Red White IO TWP-2475W-FW TWP-24MCWH-FR Red TWP-24MCWH-FW White Speaker Strobe ET70WP-2475W-FR Red ET70WP-2475W-FW White ET70WP-24 185W-FR Red ET70WP-24185W-FW White ET70WP-24135W-FR Red ET70WP-24135W-FW White Wall Mount RSSWP MTWP D 1"i 5 1~0 ASWP ET70WP Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475W-FW White 3034 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCWH-FW White 5165 Audible Strobe ASWP-2475W-FR Red 9012 ASWP-24MCWH-FR Red 5137 ASWP-24MCWH-FW White 5140 UL Max. Current AH 24 VDC 12 VDC High (99) dBA 0.080 0.192 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 FUL Reverberant dBA l? 10 Feet IVatts 1/8 1/4 1/2 1 2 4 8 ET-1010 77 80 83 86 87192 94 [ET70WP 78 81 84 187 190 193 95 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOT1FICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. ILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR ERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU D/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Ceiling Mount Wall or Ceiling Mount 1ir j L11117 RSSWP MTWP MT • MI 110 ASWP E17OWP - ET-1010 Strobe Order Code RSSWP-2475C-FR Red 4338 Audible Order Code RSSWP-2475C-RN White 4446 AH-24WP-R Red 7416 RSSWP-24MCCH-FR Red 5167 AH-12WP-R Red 7415 RSSWP-24MCCH-FWWhite 5187 Horn Audible Strobe MT-1 2/24-R Red 5023 ASWP-2475C-FR Red 4251 ASWP-2475C-FW White 4502 Speaker ASWP-24MCCH-FR Red 5149 ET-1010-R Red 3135 ASWP-24MCCI-l-FW White 5157 ET-1010-W White 3137 8420 Multi-tone Strobe 3112 MTWP-2475C-FR Red 4457 5132 MTWP-2475C-FW White 4478 5134 MTWP-24MCCH-FR Red 5102 MTWP-24MCCH-RN White 5122 9077 Speaker Strobe 3179 ET70WP-2475C-FR Red 4452 4885 ET70WP-2475C-RN White 4454 4891 ET70WP-24177C-FR Red 4845 4872 ET70WP-24177C-FW White 4859 4875 ET70WP-24115C-FR Red 4550 ET70WP-24115C-FW White 4732 Candela Ratings Sees UL 1971 UL 1638 c 77°F UL 1638 -40°F RSS, ET70WP and MTWP UL Max Current (Strobe Only) ASWP _____ _ High Med Low 2475W 3Q** 180 115 0.138 0.168 0.155 0.150 2475C 15 180 115 0.138 0.168 0.155 0.150 135 135 56 1 0.300 0.355 0.340 0.335 -I MC WI 185 185 77 0.420 0.480 0.465 0.460 MCCH 115 115 47 0.300 0.355 1 0.340 0.335 177 177 73 0.420 0.480 1 0.465 0.460 24185 185 185 77 0.420 **Wall mount rating only 24177 177 177 73 0.420 UL Max. Current (Audible) MTWP/MT 24 VDC MT 12 VDC IBA HI STD HI STD Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 Time 0.104 0.038 0.142 0.034 I March ode 3 Horn 0.091 0.035 0.142 0.034 ode 3Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Hi/Lo 0.057 0.025 0.114 0.026 Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X - RSSWP-24MCWH X - X - - RSSWP-24MCCH X - X - - Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X - X - - ASWP-MCCH X - X - - Multitone Strobe MTWP-2475 X X X X - MTWP-MCWH X - X - - MTWP-MCCH X - X - - Homs/Audibles AH-24WP X X X X X AH-12WP X X X X X MT-12/24 X X X X X Speaker Strobe ET70WP-2475 X - X X - ET70WP-185 X - X X - ET70WP-177 X - X X - ET70WP-115 X - X X - ET70WP-135 X - X X - CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0131 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: ModelsAS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1 215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. *Models AS-1 21575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *AsWp..2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASWP24MCWH and *ASWP24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7125-0785:0131 Page 2 of 2 RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:l5cd, 1575:15/75cd ,30:30cd ,75:75cd ,95:95cd, 100:100cd, 110:ll0cd MCW: Selectable 15cd, 30cd, 75cd,110cd MCC: Selectable 15cd, 30cd,75cd, 95cd MCWH: Selectable 135cd,185cd(65cd, 90cd at-40 C) MCCH: Selectable 115cd,177cd (50cd, 75cd at-40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP-24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix -w or WH are for wall mount only. Models with suffix -C or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *Aswp2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12124 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: ModelsAH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing 0 impaired applications. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct . ?V1 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division