HomeMy WebLinkAbout2721 LOKER AVE W; ; FPC2020-0201; Permit41 1IIII i1s1il
C7city of
Carlsbad
Iirieiae:r1mit
Print Date: 12/15/2020
Job Address: 2721 LOKER AVE W, CARLSBAD, CA 92010-6601
Permit Type: FIRE-Construction Commercial Work Class
Parcel #: 2090814000 Track #:
Valuation: $0.00 Lot #:
Occupancy Group: Project #:
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #:
Plan Check#:
Permit No: FPC2020-0201
Status: Closed - Finaled
Fire Alarm
Applied: 11/19/2020
Issued: 12/01/2020
Finaled Close Out: 12/15/2020
Inspector:
Final Inspection:
Project Title:
Description: LOW VOLTAGE -REPLACE DEDICATED FUNCTION FIRE SPRINKLER PANEL & CONNECT EXISTING SPRINKLER DEVICES USING
EXISTING WIRING
Applicant: FPContractor:
LOW VOLTAGE INTEGRATED SYSTEMS LOW VOLTAGE FIRE INC
KYLE ARGUIJO 1090JOSHUA WAY, #UNITA
1090 JOSHUA WAY, # STE A VISTA, CA 92081-7800
VISTA, CA 92081-7800 (760) 598-4110
(760) 598-4110
FEE AMOUNT
FIRE Reinspection (per inspection) $193.00
FIRE Sprinkler Monitoring $383.00
Total Fees: $576.00 Total Payments To Date: $576.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
DEDICATED FUNCTION SYSTEM
SUBMITTAL
L W%#%00
i r t et. g r ci t s y s t c3r rn s
FIRE ALARM S SOUND S DATA • MEDIA S SECIJRITYS CCTV S ACCESS CONTROL
DEDICATED FUNCTION FIRE SPRINKLER SYSTEM
REPLACEMENT TI
2721 Loker Ave. W.,
Carlsbad CA 92010
LOW VOLTAGE INTEGRATED SYSTEMS, INC.
1090 JOSHUA WAY, STE A
VISTA, CA 92081
(760) 598-4110 Phone
(760) 598-4107 Fax
info@sdlvis.com
License: CIO, C16 # 791832
\1
( (,
Search dmpaarms
Powerful
addressable fire
system
Proven reliability suitable for commercial and industrial
installations
On-Board 10/100 Network Communication
Full range of zone expansion, communication, and
relay output capability
Flash tJpdateable: No more firmware chips to replace
Adaptive Technology1M - Cost-effective supervised
cellular backup
DMP XR150FC/XR550FC Series panels deliver true
flexibility and expandability to cover all your fire needs.
XR150FC/XR550FC SERIES COMMERCIAL FIRE PANELS
SYSTEM FEATURES
Up to 562 two-wire smoke detector or fire initiating zones on
XR55OFC
Up to 142 two-wire smoke detector or fire initiating zones on
XR1 5OFC
Up to .5 Amps 12 VDC smoke and auxiliary output with OVC
protection
Up to .7 Amps 12 VDC supervised bell output
Up to 506 fully-programmable Form C relays
Serial 3 Digital Dialer or dO reporting to multiple receivers
Eight communication paths between the panel and Central Station
Multiple on-board status LEDs
Up to 100 output schedules to control relays and panel outputs
32 individual reporting areas, with common areas
Output Groups: Maximum functionality—Minimum programming
XR150DNFC/XR5500NFC SYSTEM FEATURES
All above listed System Features
On-board Ethernet connection for Network MonitoringTM
Customizable check-in time and retry time
Suitable for multi-site applications where the Internet or
LAN/WAN is available
Built-in remote or on site feature upgrade capability
12,000 event buffer _.--TT.
Multi lingual menus available by user._-
XR150FC&XR550FC FIRE PANELS
The XR1 5ODFC and XR550DFC provide basic fire monitoring for any single site application. The XR1 500NFC and XR5500NFC panels provide
all the same basic fire monitoring as the XR1500FC and XR5500FC enhanced by the on-board Ethernet connection that allows the use of
Network MonitoringTM. Both panels come fully assembled from the factory with the following components:
CONTROL PANEL
The XR1 50FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DACT. NET, or Cell
communication to the central station. The microprocessor based panel also provides input for Class A zone expansion. conventional and
addressable smoke detectors, pull stations, and heat detectors.
ENCLOSURE
The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security, the enclosure comes with a lock
and key.
KEYPAD ANNUNCIATOR
The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts,
making it efficient and easy-to-use.
TRANSFORMER AND ENCLOSURE
The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection.
XR150FC/XR550FC TYPICAL NOTIFICATION/ANNUNCIATION
12 or 24 VDC
12or24VDC
NAC1
L.
c Module Strobe Mini-Horn
or 24 vocI
C111
NAC 2 2or24VDC
NAC 2 Power Supply Sync Module Horn Strobe
505-12 or other 12/24VDC UL _______
Motor Bell
Commercial Fire Approved Digital
M
Fire Command
Digital SLC Power SuppLies Annunciator Bus
Loop2
DigitalSLC
Additional 630F
Any expansion device Loop 1
can operate on SLC Loop Centers
1or2 630F Fire
Command Center
FIBLE COMMUNICATION
The XR1 5DDNFC and XR550DNFC
has transitioned from dialer-focused
communications to a true network and
cellular communications approach by
providing stronger, multi-layered panel
communications that ensure a constant
link between the panel and Central Station.
Installers have the ability to create, configure
and manage up to eight communication
paths.
The unique DMP Serial 3 format supports 16
or 32-character user, zone and area names
to decrease the central station response time
and limit dependence on automation literal
tables for message conversion.
NETWORK OR CELLULAR
COMMUNICATION
Built-in 10/100 auto-sensing Ethernet
connection enhances both standard and
encrypted line security options. Both UDP and
TCP are supported. The network option can
be used as the primary or backup path to the
digital dialer or cellular option.
The XR150FC and XR550FC Series Panels
may be used with the 263C or 263H Digital
Cellular Communicator as the primary path
(no backup required) for commercial fire
installations.
The check-in and fail time settings are
programmed for five minutes. As the backup
path, the 263C or 263H provides the security
of a communication link that continues to
function, even when land lines are cut or
compromised. The communicators can be
used as a stand-alone communicator without
the need for a backup. This interface works on
digital Cellular data networks over a variety of
carriers in the USA and Canada.
OUTPUTS
The XR150FC and XR550FC aLLotheuse'
XR15DFC/ of two SPOT relay outputs and four open
B modules collector outputs, that may be activated by
865 or zone or system events, by schedule, through
combined the User Menu or when a card is presented.
additional 4 Output Groups allow multiple outputs to
)fl the SLC activate with a single event and/or can be
assigned to a particular user profile.
EIGHT COMMUNICATION PATHS
Create, configure, and manage up to eight
communication paths between the panel and
Central Station. Each path has its own panel
communication programming parameters,
and can be identified as either primary or
backup. This enables installers to configure a
reliable communication (ink, offering greater
confidence that the panel will always be
connected to the Central Station.
COMMUNICATION FUNCTION
DIAGNOSTICS
The enhanced diagnostic menu enables
technicians to check network and cellular
communication status, cell signal strength,
and email status from the keypad.
FIRE ZONE PROGRAMMING
Program zones for fire, fire verify, fire retard.
presignal, cross zoning, or fire supervisory.
This flexibility allows the ability to match
individual zone characteristics to the needs
of any area in the fire installation.
ZONE EXPANSION
The XR1 50FC and XR550FC provide up to 570
zones, programmable for a variety of fire
applications. The system provides Class B
12 VDC powered zones, two on-board and
four on the 715 Module, plus eight panel
burglary zones. Up to 60 zones are available
on 15 keypad addresses and up to 100 zones
are available on each built-in LXBusTM using
Expansion Modules.
FIRE VERIFY
Used primarily for smoke detector circuits to
verily the existence of an actual fire condition.
When a Fire Verify zone initiates an alarm,
the panel performs a Sensor Reset. If any
Fire Verify zone initiates an alarm within 120
seconds after the reset, an alarm is indicated.
If an alarm is initiated after another 120
seconds, the cycle is repeated.
Model
NOTIFICATION CIRCUIT
EXPANSION
Easily add NAC outputs to the
XR550FCsystem. Up to three Class
can be mounted within the FACP. I
866 Class B NAC Modules may be
with a power supply to provide
Amp NAC outputs. Use an 867
Loop to further expand NAC circuits.
FIRE DRILL AND ONE-MAN
WALK TEST
Users can test fire notification bells using
the Fire Drill feature. A special code is also
available for installers to test the system. The
one-man walk test feature allows a single
technician to check the panel response to
fire, burglary, panic and supervisory zones.
BUILT-IN PROGRAMMER
AND DIAGNOSTICS
No programming device is required, enabling
installers and service technicians to fully
program the system and run diagnostics from
any DMP LCD keypad. Check the electrical
state of zones, find individual zone numbers.
check the LX-Bus for Missing. Overlapping
and/or Extra zones, and much more, all from
any OMP LCD keypad.
FLASH UPDATEABLE
The XR150FC and XR550FC panels accept
software updates from a remote location
using Remote LinkTM software. When new
XR150FC/XR550FC feature updates release,
perform the flash update remotely.
OUTPUT SCHEDULES
Achieve maximum system flexibility with
100 programmable schedules that simplify
planning and operations. Control any
contact-activated device with schedules that
automatically regulate relays and switched-
ground outputs.
MULTI-LINGUAL DISPLAYS
For additional flexibility, keypads attached to
the XR1 50FC and XR550FC panels can display
keypad Status List and User Menu text using
multiple languages. The user has the option
to select the language to use.
STATUS LIST
To provide maximum system flexibility, fire
zones may be programmed to display at a
specific keypad. In this manner, all fire zones
can be monitored in one location and other
zones can be programmed to display and be
monitored at different keypad Locations.
12,000 EVENT MEMORY
Allows the user to view the last 10,000
door accesses or 2,000 system events that
occurred over the past 45 days.
REMOTE LINK
The Remote Link programming software
takes advantage of the easy-to-use simplicity
of MicrosoftO WindowsTM. The XR150FC and
XR550FC include an interface connection for
installers to use to connect a laptop computer.
- .---.----- -.--------
-.------- I
cK1
KEYPADS
630F LCD Remote Fire Command
EXPANSION MODULES
710 Bus Splitter/Repeater
711 Single Zone Expansion
714 4-zone Class-B Expansion
714-8 8-zone Class-B Expansion
714-16 16-zone Class-B Expansion
715 4-zone 2-wire smoke Expansion
715-8 8-zone 2-wire smoke Expansion
715-16 16-zone 2-wire smoke Expansion
716 Output Expansion,
4 Form C relays.
4 open collector outputs
717 Graphic Annunciator: 20 open
collector outputs
AUXILIARY MODULES
860 Relay Output Module
865 Style W/X Notification Circuit
Module
866 Style W Notification Circuit
Module
867 LX-Bus Notification Circuit
Module
869 Style 0 Class A Initiating Circuit
Module
893A Dual Phone Line Module
POWER SUPPLIES
505-12/LX 5 Amps @ 12 VDC
505-12L 5 Amps @12VDC
505-12A 5 Amps @12VDC
PULL STATIONS
850 Series Pull Stations
SMOKE/HEAT DETECTORS
521 B/BXT Conventional Smoke, CleanMe
521 LX/LXT Addressable Smoke/Heat.
CleanMe
ACCESSORIES
270 Network Transient Suppressor
277 Commercial Fire Buzzer Module
300 Four-wire Harness
303 Silence/Reset Push-Button
305 Plug-in Output Relay
306 Tamper Harness
307-S Screw-On Tamper Switch
3012 Clip-On Tamper Switch
335 Intrusion Siren
370 Lightning Suppressor
374 Surge Voltage Suppressor
381-2 18 Coax Extension
431 Output Harness
861 Power Distribution Module
CENTRAL STATION RECEIVERS
SCS-1 R Network Enabled Receiver
Compatable with Central Station
Receivers that accept Standard CID,
DD, or DMP Serial 3 messaging
SCS-VR (Virtual Receiver) Software only
solution that runs on a server for network
IP and cellular communications
DMP WIRELESS
1100X Receiver
1100XH High Power Receiver
hOUR Repeater
1103 Universal Transmitter,
External Contact
1165 Commercial Smoke
Detector
1165H Commercial Smoke/Heat
Detector
1165HS Commercial Smoke/Heat
Detector with Sounder
1181 Post Indicator Valve (UL)
1182 Outside Screw and Yoke Valve
Supervisory Switch (UL)
1183-135F Heat Detector
1183-135R Heat Detector
1184 Carbon Monoxide Detector
COMPUTER SOFTWARE
Remote Link Upload/Download
Programming Software
System Link End-User Management
Software
Alarm Monitoring Module
Command Center Module
Advanced Reporting Module
Account Groups Module
Link Server Application
N CELLULAR COMMUNICATORS
263C COMA Cellular Communicator
263H HSPA+ Cellular Communicator
263HCAN HSPA+ Cellular Communicator
(All require a 381 cable)
SYSTEM SPECIFICATIONS
Primary Power (included) 16 VAC 56 VA transformer
Secondary Power 12 VDC Battery
Models 365, 366. 368 or 369
Output Rating
Bell Up to .7 Amps at 12 VDC
Smoke and Auxiliary Up to .5 Amps at 12 VDC
For UL installations, total bell, smoke, and auxiliary cannot
exceed 1.2 Amps using a 56 VA transformer.
Current Draw 180mA
Enclosure:
Material Cold-rolled steel (Red)
ORDERING INFORMATION
XR1500FC-R XR150 Fire Control Panel
XR1 500NFC-R XR1 50 Fire Control Panel with
Network
XR5500FC-R XR550 Fire Control Panel
XR550DNFC7R XR550 Fire Control Panel with
-.
...................Network - .-
LISTINGS AND APPROVALS
Refer to the XR150FC/XR550FC Installation Guide (LT-1297), XR150FC/
XR550FC Programming Guide (LT-1232) and specific compliance listings
for installation and programming requirements necessary to meet a
particular approval.
FCC Part 68
FCC Part 15
Underwriters Laboratories (UL) Listed
ANSI/UL 864 Fire Protective Signaling
For approval information, access www.dmp.com and select Compliance.
now MV,
ii 0 ii DnEngied& Assembled Springfield. Missouri 658M-8M
in Springfield, Missouri
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7165-1157:O135j Page 1 of 2
CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)
LISTEE: Digital Monitoring Products, lnc.2500 N. Partnership Blvd, Springfield, MO 65803
Contact: Amy Bade (417) 831-9362 Fax (417) 447-9698
Email: abade@dmp.com
DESIGN: Model4_XR15O,IXR350 and XR550 combination fire and burglary alarm control units. Local,
remote station, proprietary and central station services. Models may have a combination of
the following suffixes: D (dialer), N (network), E (encryption) oj FC (fire control). I Refer to
listee's data sheet for additional detailed product description and operational considerations.
System components:
XR150, XR350, XR550: Main Board
341, 349, 350, 350A, 352P 352X: Enclosures
352S: Battery Enclosure
630F: Supervised LCD Keypad
7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD
Keypads
325: Transformer Bracket
322, 323, 324, 324P, 327: Transformers
711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders
*711S: Zone Expander (NOT for use with XR350)
Output Expander
Annunciator Module
860 Relay Module
893A: Dual Phone Line Module
734, 734N: Wiegand Interface
710: Bus Splitter
270: Network Transient Suppression Module
277: Trouble Sounder
9060, 9063: Wireless Keypads
I 263C, 2631-1: Cellular Communicator (May be used as the standalone primary communicator) I
263LTE: Cellular Communicator (NOT for use with XR350) (May be used as the standalone
primary communicator)
865, 866, 867: Indicating Module
869: Initiating Module
303: Reset/Silence Switch
1100X, 1100XH: RE Wireless Receiver
IlOOR: Wireless Repeater
1103: Wireless Transmitter
*Rev 04-05-19 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2020 Listing Expires June 30, 2021
Authorized By: DAVID CASTILLO,, ME., F.P.E.
Fire Engineering Division
Listing No. 7165-1157:0135
Page 2 of 2
1135: Wireless Siren
RATING: 120 VAC, 0.5 A, 60 Hz
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number, rating and UL label.
APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed
electrically compatible initiating and indicating devices. Refer to 1iste3's Installation
Instructions Manual for details.
NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum
Retard/Reset/Restart period shall not exceed 30 seconds.
2. Burglary and other non-fire functions were not examined.
*Rev 04-05-19 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2020 Listing Expires June 30, 2021
Authorized By: DAVID CASTILLO,, M.E., F.P.E.
Fire Engineering Division
O't-_ SYSTEM
$ SENSOR"
Photoelectric
Smoke Detectors
System Sensor /3" series smoke detectors represent
significant advancement in conventional detection.
The j3 family is founded on three principles: installation
ease, intelligence, and instant inspection.
Features
Plug-in detector line, mounting base included
Large wire entry port
In-line terminals with SEMS screws
Mounts to octagonal and single-gang back boxes, 4-square back
boxes, or direct to ceiling
Stop-Drop 'N Lock attachment to base
Removable detector cover and chamber
Built-in remote maintenance signaling
Drift compensation and smoothing algorithms
Simplified sensitivity measurement
Wide-angle, dual-color LED indication
Loop testing via EZ Walk feature
Built-in test switch
Agency Listings
® MEA MSFM C(gl)US LISTED APPROVED approved approved
5911 3011446 7272-1653:152 290-01-E 2093 3180932
Installation ease.The i3 line redefines installation ease with its
plug-in design. This allows an installer to pre-wire bases (included
with heads). The large wire entry port and in-line terminals provide
ample room for neatly routing the wiring inside the base. The base
accommodates a variety of back box mounting methods as well as
direct mounting with drywall anchors. To complete the installation, i3
heads plug into the base with a simple Stop-Drop 'N Lock" action.
Intelligence. i3 detectors offer a number of intelligent features
to simplify testing and maintenance. Drift compensation and
smoothing algorithms are standard with the j3 line to minimize
nuisance alarms. 2-wire P detectors can generate a remote LED-
indicated maintenance signal when connected to the 2W-MOD2
loop test/maintenance module or a panel equipped with the
protocol. The SENS-RDR, a wireless device, displays the sensitivityofi3
detectors in terms of percent-per-foot obscuration.
Instant inspection.The i3 series provides wide-angle red and
green LED indicators for instant inspection of the detector's
condition: normal standby, out-of-sensitivity, alarm, or freeze trouble.
When connected to the 2W-MOD2 loop test/maintenance module
or a panel with the j3 protocol, the EZ Walk loop test feature is
available on 2-wire P detectors, This feature verifies the initiating loop
wiring by providing LED status indication at each detector.
Otj
43-) Smoke Detector Specifications
Smoke detector shall be a System Sensor il Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The
detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4W1-B) with thermal sensor rated at 135°F
(57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster
ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the
base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The
detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual-
color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used
in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel
and shall provide a loop testing capability to verify the circuit without testing each detector individually.
Electrical Specifications ~4-
Operating Voltage Nominal: 12/24 V non-polarized
Minimum: 8.5V
Maximum: 35V
Maximum Ripple Voltage 30% peak to peak of applied voltage
IStandby Current 2-wire: 50 pA maximum average 4-wire: 50 pA maximum average
I Maximum Alarm Current 2-wire: 130 mA limited by control panel;14-wire: 20mA @12 V 23 mA @ 24V
Peak Standby Current 2-wire: 100 pA; 4-wire: n/a
Alarm Contact Ratings 2-wire: n/a; 4-wire: GSA @30 V Ac/DC
Dimensions (including base) 53 inches (127 mm) diameter; 2.0 inches (51 mm) height
Weight 6.3 OZ (178 g)
Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C)
Operating Humidity Range 0 to 95% RH non-condensing
Thermal Sensor 135°F (57.2°C) fixed
Freeze Trouble 2W1-B and 4\A'T-B only: 41°F (5°C)
Sensitivity 2.50/o/ft nominal
Input Terminals 14 to 22 AWG
Mounting 31/2-inch octagonal back box
4-inch octagonal back box
Single-gang back box
4-inch square back box with a plaster ring
Direct mount to ceiling
LED Modes Power-Up Sequence for LED Indkat1onM1':','4t.JdJK";
LED Mode Green LED Red LED Condition Duration
Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds
Normal (standby) Blink every 5 seconds off
Out of sensitivity off Blink everv5 seconds
Freeze trouble off Blink every 10 seconds
Alarm off Solid
Orderina Information
I 2W-B I No 2-wire 130 mA max. limited by control panel
2WT-B Yes 2-wire 130 mA max. limited by control panel
4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V
4W1-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24V
Accessories
2W-MOD2 2-wire loop test/ maintenance module RT Removal / replacement tool
SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter
3825 Ohio Avenue. St. Charles, IL 60174
current product information, ~ncluding the latest -,on of this data shc~t, Phone: 800-SENSOR2• Fax: 630-377-6495 A05-0318-007-6/09. #2169
I
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 17272-1653:0152 I Page 1 of 1
CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC
LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL
60174
Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309
Email: megan.sissonhoneywell.com
DESIGN: ModelsI2W-B,I2WT-13, 4W-B, and 4WT-B photoelectric type smoke detectors. Models 2W-B
and 2WT-B are 2-wire and models 4W-B and 4WT-B are 4-wire detectors. Models 2Wr-B
and 4W1-B employ a thermistor type heat sensor (135°F). The heat sensor is supplemental
to the detector and is not intended for use as a required heat detector. Refer to listee's
printed data sheet for additional detailed product description and operational considerations.
*The above models comply with UL 268, Seventh Edition.
RATING: 8.5-35 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances,
and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling
mount.
MARKING: Listee's name, model number, electrical rating and UL label.
APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm
control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm.
NOTE: Formerly 7272-1209:210
*Revision 09-21-20 VWVV
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2020 Listing Expires June 30, 2021
Authorized By: DAVID CASTILLO,, ME., F.P.E.
Fire Engineering Division