Loading...
HomeMy WebLinkAbout2721 LOKER AVE W; ; FPC2020-0201; Permit41 1IIII i1s1il C7city of Carlsbad Iirieiae:r1mit Print Date: 12/15/2020 Job Address: 2721 LOKER AVE W, CARLSBAD, CA 92010-6601 Permit Type: FIRE-Construction Commercial Work Class Parcel #: 2090814000 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Permit No: FPC2020-0201 Status: Closed - Finaled Fire Alarm Applied: 11/19/2020 Issued: 12/01/2020 Finaled Close Out: 12/15/2020 Inspector: Final Inspection: Project Title: Description: LOW VOLTAGE -REPLACE DEDICATED FUNCTION FIRE SPRINKLER PANEL & CONNECT EXISTING SPRINKLER DEVICES USING EXISTING WIRING Applicant: FPContractor: LOW VOLTAGE INTEGRATED SYSTEMS LOW VOLTAGE FIRE INC KYLE ARGUIJO 1090JOSHUA WAY, #UNITA 1090 JOSHUA WAY, # STE A VISTA, CA 92081-7800 VISTA, CA 92081-7800 (760) 598-4110 (760) 598-4110 FEE AMOUNT FIRE Reinspection (per inspection) $193.00 FIRE Sprinkler Monitoring $383.00 Total Fees: $576.00 Total Payments To Date: $576.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov DEDICATED FUNCTION SYSTEM SUBMITTAL L W%#%00 i r t et. g r ci t s y s t c3r rn s FIRE ALARM S SOUND S DATA • MEDIA S SECIJRITYS CCTV S ACCESS CONTROL DEDICATED FUNCTION FIRE SPRINKLER SYSTEM REPLACEMENT TI 2721 Loker Ave. W., Carlsbad CA 92010 LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1090 JOSHUA WAY, STE A VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: CIO, C16 # 791832 \1 ( (, Search dmpaarms Powerful addressable fire system Proven reliability suitable for commercial and industrial installations On-Board 10/100 Network Communication Full range of zone expansion, communication, and relay output capability Flash tJpdateable: No more firmware chips to replace Adaptive Technology1M - Cost-effective supervised cellular backup DMP XR150FC/XR550FC Series panels deliver true flexibility and expandability to cover all your fire needs. XR150FC/XR550FC SERIES COMMERCIAL FIRE PANELS SYSTEM FEATURES Up to 562 two-wire smoke detector or fire initiating zones on XR55OFC Up to 142 two-wire smoke detector or fire initiating zones on XR1 5OFC Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection Up to .7 Amps 12 VDC supervised bell output Up to 506 fully-programmable Form C relays Serial 3 Digital Dialer or dO reporting to multiple receivers Eight communication paths between the panel and Central Station Multiple on-board status LEDs Up to 100 output schedules to control relays and panel outputs 32 individual reporting areas, with common areas Output Groups: Maximum functionality—Minimum programming XR150DNFC/XR5500NFC SYSTEM FEATURES All above listed System Features On-board Ethernet connection for Network MonitoringTM Customizable check-in time and retry time Suitable for multi-site applications where the Internet or LAN/WAN is available Built-in remote or on site feature upgrade capability 12,000 event buffer _.--TT. Multi lingual menus available by user._- XR150FC&XR550FC FIRE PANELS The XR1 5ODFC and XR550DFC provide basic fire monitoring for any single site application. The XR1 500NFC and XR5500NFC panels provide all the same basic fire monitoring as the XR1500FC and XR5500FC enhanced by the on-board Ethernet connection that allows the use of Network MonitoringTM. Both panels come fully assembled from the factory with the following components: CONTROL PANEL The XR1 50FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DACT. NET, or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion. conventional and addressable smoke detectors, pull stations, and heat detectors. ENCLOSURE The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security, the enclosure comes with a lock and key. KEYPAD ANNUNCIATOR The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. TRANSFORMER AND ENCLOSURE The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. XR150FC/XR550FC TYPICAL NOTIFICATION/ANNUNCIATION 12 or 24 VDC 12or24VDC NAC1 L. c Module Strobe Mini-Horn or 24 vocI C111 NAC 2 2or24VDC NAC 2 Power Supply Sync Module Horn Strobe 505-12 or other 12/24VDC UL _______ Motor Bell Commercial Fire Approved Digital M Fire Command Digital SLC Power SuppLies Annunciator Bus Loop2 DigitalSLC Additional 630F Any expansion device Loop 1 can operate on SLC Loop Centers 1or2 630F Fire Command Center FIBLE COMMUNICATION The XR1 5DDNFC and XR550DNFC has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 16 or 32-character user, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series Panels may be used with the 263C or 263H Digital Cellular Communicator as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path, the 263C or 263H provides the security of a communication link that continues to function, even when land lines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works on digital Cellular data networks over a variety of carriers in the USA and Canada. OUTPUTS The XR150FC and XR550FC aLLotheuse' XR15DFC/ of two SPOT relay outputs and four open B modules collector outputs, that may be activated by 865 or zone or system events, by schedule, through combined the User Menu or when a card is presented. additional 4 Output Groups allow multiple outputs to )fl the SLC activate with a single event and/or can be assigned to a particular user profile. EIGHT COMMUNICATION PATHS Create, configure, and manage up to eight communication paths between the panel and Central Station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication (ink, offering greater confidence that the panel will always be connected to the Central Station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and email status from the keypad. FIRE ZONE PROGRAMMING Program zones for fire, fire verify, fire retard. presignal, cross zoning, or fire supervisory. This flexibility allows the ability to match individual zone characteristics to the needs of any area in the fire installation. ZONE EXPANSION The XR1 50FC and XR550FC provide up to 570 zones, programmable for a variety of fire applications. The system provides Class B 12 VDC powered zones, two on-board and four on the 715 Module, plus eight panel burglary zones. Up to 60 zones are available on 15 keypad addresses and up to 100 zones are available on each built-in LXBusTM using Expansion Modules. FIRE VERIFY Used primarily for smoke detector circuits to verily the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. Model NOTIFICATION CIRCUIT EXPANSION Easily add NAC outputs to the XR550FCsystem. Up to three Class can be mounted within the FACP. I 866 Class B NAC Modules may be with a power supply to provide Amp NAC outputs. Use an 867 Loop to further expand NAC circuits. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The one-man walk test feature allows a single technician to check the panel response to fire, burglary, panic and supervisory zones. BUILT-IN PROGRAMMER AND DIAGNOSTICS No programming device is required, enabling installers and service technicians to fully program the system and run diagnostics from any DMP LCD keypad. Check the electrical state of zones, find individual zone numbers. check the LX-Bus for Missing. Overlapping and/or Extra zones, and much more, all from any OMP LCD keypad. FLASH UPDATEABLE The XR150FC and XR550FC panels accept software updates from a remote location using Remote LinkTM software. When new XR150FC/XR550FC feature updates release, perform the flash update remotely. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched- ground outputs. MULTI-LINGUAL DISPLAYS For additional flexibility, keypads attached to the XR1 50FC and XR550FC panels can display keypad Status List and User Menu text using multiple languages. The user has the option to select the language to use. STATUS LIST To provide maximum system flexibility, fire zones may be programmed to display at a specific keypad. In this manner, all fire zones can be monitored in one location and other zones can be programmed to display and be monitored at different keypad Locations. 12,000 EVENT MEMORY Allows the user to view the last 10,000 door accesses or 2,000 system events that occurred over the past 45 days. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of MicrosoftO WindowsTM. The XR150FC and XR550FC include an interface connection for installers to use to connect a laptop computer. - .---.----- -.-------- -.------- I cK1 KEYPADS 630F LCD Remote Fire Command EXPANSION MODULES 710 Bus Splitter/Repeater 711 Single Zone Expansion 714 4-zone Class-B Expansion 714-8 8-zone Class-B Expansion 714-16 16-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion 715-8 8-zone 2-wire smoke Expansion 715-16 16-zone 2-wire smoke Expansion 716 Output Expansion, 4 Form C relays. 4 open collector outputs 717 Graphic Annunciator: 20 open collector outputs AUXILIARY MODULES 860 Relay Output Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style 0 Class A Initiating Circuit Module 893A Dual Phone Line Module POWER SUPPLIES 505-12/LX 5 Amps @ 12 VDC 505-12L 5 Amps @12VDC 505-12A 5 Amps @12VDC PULL STATIONS 850 Series Pull Stations SMOKE/HEAT DETECTORS 521 B/BXT Conventional Smoke, CleanMe 521 LX/LXT Addressable Smoke/Heat. CleanMe ACCESSORIES 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push-Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18 Coax Extension 431 Output Harness 861 Power Distribution Module CENTRAL STATION RECEIVERS SCS-1 R Network Enabled Receiver Compatable with Central Station Receivers that accept Standard CID, DD, or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications DMP WIRELESS 1100X Receiver 1100XH High Power Receiver hOUR Repeater 1103 Universal Transmitter, External Contact 1165 Commercial Smoke Detector 1165H Commercial Smoke/Heat Detector 1165HS Commercial Smoke/Heat Detector with Sounder 1181 Post Indicator Valve (UL) 1182 Outside Screw and Yoke Valve Supervisory Switch (UL) 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Alarm Monitoring Module Command Center Module Advanced Reporting Module Account Groups Module Link Server Application N CELLULAR COMMUNICATORS 263C COMA Cellular Communicator 263H HSPA+ Cellular Communicator 263HCAN HSPA+ Cellular Communicator (All require a 381 cable) SYSTEM SPECIFICATIONS Primary Power (included) 16 VAC 56 VA transformer Secondary Power 12 VDC Battery Models 365, 366. 368 or 369 Output Rating Bell Up to .7 Amps at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For UL installations, total bell, smoke, and auxiliary cannot exceed 1.2 Amps using a 56 VA transformer. Current Draw 180mA Enclosure: Material Cold-rolled steel (Red) ORDERING INFORMATION XR1500FC-R XR150 Fire Control Panel XR1 500NFC-R XR1 50 Fire Control Panel with Network XR5500FC-R XR550 Fire Control Panel XR550DNFC7R XR550 Fire Control Panel with -. ...................Network - .- LISTINGS AND APPROVALS Refer to the XR150FC/XR550FC Installation Guide (LT-1297), XR150FC/ XR550FC Programming Guide (LT-1232) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Fire Protective Signaling For approval information, access www.dmp.com and select Compliance. now MV, ii 0 ii DnEngied& Assembled Springfield. Missouri 658M-8M in Springfield, Missouri CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:O135j Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products, lnc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Bade (417) 831-9362 Fax (417) 447-9698 Email: abade@dmp.com DESIGN: Model4_XR15O,IXR350 and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) oj FC (fire control). I Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders *711S: Zone Expander (NOT for use with XR350) Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads I 263C, 2631-1: Cellular Communicator (May be used as the standalone primary communicator) I 263LTE: Cellular Communicator (NOT for use with XR350) (May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RE Wireless Receiver IlOOR: Wireless Repeater 1103: Wireless Transmitter *Rev 04-05-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 1135: Wireless Siren RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to 1iste3's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. *Rev 04-05-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division O't-_ SYSTEM $ SENSOR" Photoelectric Smoke Detectors System Sensor /3" series smoke detectors represent significant advancement in conventional detection. The j3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings ® MEA MSFM C(gl)US LISTED APPROVED approved approved 5911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease.The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop 'N Lock" action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the j3 line to minimize nuisance alarms. 2-wire P detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the protocol. The SENS-RDR, a wireless device, displays the sensitivityofi3 detectors in terms of percent-per-foot obscuration. Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the j3 protocol, the EZ Walk loop test feature is available on 2-wire P detectors, This feature verifies the initiating loop wiring by providing LED status indication at each detector. Otj 43-) Smoke Detector Specifications Smoke detector shall be a System Sensor il Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4W1-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications ~4- Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage IStandby Current 2-wire: 50 pA maximum average 4-wire: 50 pA maximum average I Maximum Alarm Current 2-wire: 130 mA limited by control panel;14-wire: 20mA @12 V 23 mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: GSA @30 V Ac/DC Dimensions (including base) 53 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 OZ (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2W1-B and 4\A'T-B only: 41°F (5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indkat1onM1':','4t.JdJK"; LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink everv5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Orderina Information I 2W-B I No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V 4W1-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24V Accessories 2W-MOD2 2-wire loop test/ maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter 3825 Ohio Avenue. St. Charles, IL 60174 current product information, ~ncluding the latest -,on of this data shc~t, Phone: 800-SENSOR2• Fax: 630-377-6495 A05-0318-007-6/09. #2169 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17272-1653:0152 I Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: ModelsI2W-B,I2WT-13, 4W-B, and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and models 4W-B and 4WT-B are 4-wire detectors. Models 2Wr-B and 4W1-B employ a thermistor type heat sensor (135°F). The heat sensor is supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. *The above models comply with UL 268, Seventh Edition. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 *Revision 09-21-20 VWVV This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division