HomeMy WebLinkAbout7150 RANCHO SANTA FE RD; ; FA150041; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA150041 7150 RANCHO Job Address: Status: ISSUED SANTA FE RD Permit Type: FALARM Applied 6/24/2015 Parcel No: 2238120200 Approved: 6/26/2015 Lot #: 0 Reference No.: Issued: 6/26/2015 PC #: Inspector: Project Title: PRESTIGE ACADEMY DAYCARE NEW FIRE ALARM SYSTEM FOR A DAY CARE TYPE E BUILDING. THE SYSTEM CONSISTS OF: - FIRE LARM CONTROL PANEL WITH A BUILT-IN DIALER FOR REMOTE MONITORING (24 HR ATTENDED LOCATION) -SMOKE DETECTOR ABOVE THE FIRE ALARM CONTROL PANEL & SLEEPING AREA -REMOTED ANNUNICATION AT THE MAIN ENTRY -NOTIFICATION THROUGHOUT BUILDING -SPRINKLER SYSTEM MONITORING OF THE WATER FLOW SWITCH & BUTTERFLY TAMPER SWITCH -THE ADDRESSABLE DEVICES WILL BE CONNECTED TO THE FIRE ALARM CONTROL PANEL INTELLIGENT LOOP. ALL DEVICES WILL HAVE A TEXTUAL DISPLAY ON THE FIRE CONTROL PANEL DESCRIBING TYPE OF DEVICE AND LOCATION. Applicant: KOR FIRE & SECURITY 26812 VISTA TERRACE LAKE FOREST, CA 92630 Owner: CARLSBAD PRESCHOOL LTD PTNSHP C/O GLEN WOOD DEVELOPMENT GRP 505 N BRANCH BLVD #830 GLENDALE CA 949-273-8340 Fees ($) Add'[ Fees ($) Total ($) Balance ($) 478 0 478 0 SUBMITTAL BOOKLET FOR Prestige Academy Daycare 7150 Rancho Santa Fe Road Carlsbad, CA FIRE & SECURITY "Our Knowledge Is Your Security" 26812 Vista Terrace Lake Forest, Ca. 92630 California State License: 857710 FAiS0041 DF-52422:13 • A1-40 MS9200UDLS(E) FlreLITeALarms Intelligent Addressable FACP (a with Built-In Communicator by Honeywell I 1 General The Fire-Lite MS-9200UDLS is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/ Transmitter) all on one circuit board. This compact, cost-effec- tive, intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UDLS may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeedTM mode—Fire•Lite's latest polling tech- nology—for a quicker device response time. LiteSpeed's pat- ented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 sec- onds. With Litespeed polling, devices can be wired on stan- dard twisted, unshielded wire up to a distance of 10,000 feet. (Consult the wire table on page 3 for specific installation instructions.) The MS-9200UDLS's quick-remove chassis protects the elec- tronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. Available accessories include LED, graphic and LCD annunci- ators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload! Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® 95 or greater, a compatible modem, and PK-CD, the Fire-Lite Upload/Download software kit, may serve as a Service Termi- nal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. New options include a UL listed printer, PRN-6F and FireLite's new IPDACT Internet Monitoring module. The IPDACT permits monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9200UDLS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACPs (Fire Alarm Control Panels). Features Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local upload/download, using PK-CD. Four Style Y (Class B) or two Class A (Style Z) NAC cir- cuits. - 6.0 amps total NAC power with optional XRM-24. Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Up to 32 ACM Series (ACM-16AT or ACM-32 series) annunciators or LCD-80F remote annunciators via EIA-485. EIA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6F. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Watertlow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). DF-52422:6 • 07/28/08 - Page 1 of 4 SLC loop maximum length 10,000 ft. (3,000m.) See wire table on page 3. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NAGs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). Silence Inhibit and Auto Silence timer options. TR-CE: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. Continuous, March Time, Temporal or California code for CHG-120F: Remote battery charging system for lead-acid bat- main circuit board NACs with two-stage capability. teries with a rating of 55 to 120 AH. Requires additional BB- Selectable strobe synchronization per NAC. 55F for mounting. 2.5 amps maximum per each NAC circuit. NOTE: Maximum or total 24VDC system power shared between all NAG circuits and auxiliary power outputs is 3.6 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PK-CD, containing PK-Plus, sepa- rately). Upload/download system programming locally to the MS-9200UDLS(E) in less than one minute. User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Ordering Options MS-9200UDLS198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet.120 VAC operation. MS-9200UDLSE: Same as MS-9200UDLS, except with 240 VAC operation. 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. PK-CD: Contains PK-Plus programming software for Win- dows®-based PC computer (cable not included). DP-9692: Optional dress panel for MS-9200UDLS BAT Series: Batteries, see data sheet DF-52397. XRM-24(E): Optional transformer. Increases system power to 6.0 amps. Use XRM-24E with MS-9200UDLS(E). PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df-52424 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT cable input. COMPA TIBLE ANNUNCIA TORS ACM-8RF: Relay module provides 8 Form-C 5.0 amp relays. ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the MS-9200UDLS, see the following data sheets (document numbers) ACM-8RFACM-8R (DF-5 1555), ACS/ACMSeries (DF- 52378), LDM Series (DF-5 1384), LCD-80F (DF-52185). LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. 5D355T: Addressable low-profile photoelectric smoke detector with thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fixed high-temperature detector that activates at 190F/88C. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (B350LP base included). CLIP MODE ONLY BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D350PL: Photoelectric low-flow duct smoke detector. Page 2 of 4 - OF-52422:B • 07/28/08 D350PL: Photoelectric low-flow duct smoke detector with relay option. MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0° (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only IDCs. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. MMF-301: Miniature version of MMF-300. Excludes LED and CRF-300-6: Six Form-C relay control module. Mount one or Style D option. Connects with wire pigtails. May mount in two modules in a BB-2F cabinet (optional). Mount up to six device backbox. modules on a CHS-6 chassis in a BB-6E MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0 (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0 (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9200UDLS, see the following data sheets (document numbers): A0355 (DF-52386), BG-I2LX (OF- 520 13), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/ CRF Series (DF-52 130), CP355 (DF-52383), D350PUD35ORPL (DF-52398), H355 Series (DF-52385), /300 (DF-52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), S0355/S0355T (DF-52384). 2) Legacy 300 Series detection devices such as the A0355, CP300/CP350, 50300(T)/S0350(T) and older modules such as the M300, M301, M302, C304, and BG- 1OLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. SLC Protocol Wire Requirements Distance in Feet (m) Wire Size Wire Type Twisted-pair, shielded 10,000 feet(3,048 m) 12 AWG (3.31 mm2) Belden 9583, Genesis 4410, Signal 98230, WPW D999 Twisted-pair, shielded 8,000 feet (2,438 m) 14 AWG (2.08 mm2) Belden 9581, Genesis 4408, Signal 98430, WPW D995 CLIP Twisted-pair, shielded 4,875 feet (1,486 m) 16 AWG (1.31 mm2) Belden 9575, Genesis 4406, & 4606, Signal 98630, WPW D991 Twisted-pair, shielded 3,225 feet (983 m) 18 AWG (0.78 mm2) Belden 9574, Genesis 4402 & 4602, Signal 98300, WPW D975 Untwisted, unshielded wire, in or out of conduit 3,000 feet (914 m) 12— 18 AWG (3.31 mm2-0.821 mm2) Non-Plenum (FPLR): Twisted-pair, unshielded 10,000 feet (3,048 m) 12 AWG (3.31 mm2) Genesis 4315, Belden 5020UL Plenum (FPLP): Genesis 4515, Belden 6020UL Non-Plenum (FPLR): Twisted-pair, unshielded 8,000 feet (2,438 m) 14 AWG (2.08 mm2) Genesis 4313, Belden 5120UL Plenum (FPLP): LiteSpeed Genesis 4513, Belden 6120UL _____________________ _________________ __________________ Non-Plenum (FPLR): Twisted-pair, unshielded 4,875 feet (1,486 m) 16 AWG (1.31 mm2) Genesis 4311, Belden 5220UL Plenum (FPLP): Genesis 4511, Belden 6220U Non-Plenum (FPLR): Twisted-pair, unshielded 3,225 feet (983 m) 18 AWG (0.821 mm2) Genesis 4306, Belden 5320UL Plenum (FPLP): Genesis 4506, Belden 6320UL MS-9200UDLS Wire Requirements DF-52422:B • 07/28/08 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits.......................................1 Addressable device capacity..........................................198 Programmable software zones.........................................99 Annunciators ....................................................................32 Electrical Specifications AC Power: MS-9200UDLS: 120 VAC, 60 Hz, 3.0 amps. MS- 9200UDLSE: 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery: Two 12 V 18AH lead-acid batteries. Battery charger capacity: 7-18 AH. MS-9200UDLS cabinet holds maximum of two 18 AH batteries. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style V (Class B) or one Style Z (Class A) for a total of four Style Y (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.71K ohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to panel documen- tation and Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Power (24 VDC Nominal): Jumper selectable (JP4) for conversion to resettable power output. Up to 0.5 amps total DC current available from each output. Power-limited. Four-Wire Resettable Special Application Smoke Detector Power (24 VDC nominal): Up to 0.5 amps for powering four- wire smoke detectors. Power-limited. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 40 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 7 volts DC. Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65° (42.29 cm.) wide x 5.20 (13.34 cm.) deep. Trim Ring (TR-CE): 22.00 (55.88 cm.) high x 19.65 (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 27°C/60 - 80°F. NFPA Standards The MS-9200UDLS complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9200UDLS control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:208 MEA: 120-06-E LiteSpeedTM is a trademark; and FireLite® Alarms is a registered trademark of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2008 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 01 :b dl U _ We cannot cover all specific applications or anticipate all requirements. lNUMANIMC1IRING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4 - DF-52422:13 • 07/28/08 CALIFORNIA DEPARTMENT OiF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0208 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Models MS-9200UD and MS-9200UDLS addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *MS9200UDLS panel also suitable for high-rise application for use with Model ECC-50/100 emergency voice evacuation panel (CSFM # 6911-0075:0226). This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev 11-12-13gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division F2 -Quick disconnect tabs, 0.250" x 0.032" - Mate with AMP. INC FASTON "250' series I- 3.4-1 16.35 7.95 --1 ii JP iäIJDimensiiiI(ñiiii) _______ • Absorbent Glass Mat (AGM) technology for superior performance stwy MODEL F2 42 Wit 12QA~p Hr. vow 0 w l E> 11 v n 'I P HT H Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.0.T., I.A.T.A., F.A.A. and C.A.B. certified U.L. recognized under file number MH 20845 Nominal Voltage........................................................................12 volts (6 cells) Nominal Capacity 20-hr. (600mAto 10.50 volts) ....................................................... 12.OAH 10-hr. (1.1A to 10.50 volts) ............................................................11.0 AH 5-hr. (2.1A to 10.20 volts) ............................................................10.5 AH 1-hr. (7.25A to 9.00 volts) .............................................................7.25 AH 15-mm. (21.5A to 9.00 volts)..............................................................5.38 AH Approximate Weight ...........................................................7.92 lbs. (3.59 kg) Energy Density (20-hr. rate) ...............................1.69 W-h/mn3 (103.41 W-h/1) Specific Energy (20-hr. rate) ..............................18.18 W-h/lb (40.08 W-h/kg) Internal Resistance (approx.) ......................................................20 milliohms Max Discharge Current (7 Mm.) ...............................................36.0 amperes Max Short-Duration Discharge Current (10 Sec.)................120.0 amperes Shelf Life (% of nominal capacity at 68°F (20'C)) 1 Month ......................................................................................................97% 3 Months.....................................................................................................91% 6 Months ....................................................................................................83% Operating Temperature Range Charge .. ........................................................... -4°F(-20°C)t0122"F(50°C) Discharge ....................................................... -40°F(-40°C)to 140°F(60°C) Case......................................................................................................ABS Plastic Power-Sonic Chargers ........................................... PSC-122000A, 122000A-C L L: 5.95 (151) W. 3.86 (98) H: 3.70 (94) HT: 3.94 (100) Tolerances are /- 0.04 in. (+!- 1mm) and /- 0.08 in. (+/-2mm) for height dimensions. All data subject to change without notice. 9a y wwwJporoniccom iuiui RIME 01111111H.P.1 M0 E~WFAM uuuiui ••IIEIIINIIINI Standing Period (Months) 8.0 Choguisnot - -.. - - - - - necessary unless 100% of capacity is required. N 5°C Changing before - i - - - - - - use is necessary (41 F) to help recover '.... bill capacity Ix Z. . - -. Osagemay fal - - - - - '°- - - to restore full 40°C 30 C 20°C I capacity. Ds not reach - (104°F)- _(86°F) - (68°F)-]--- bebattenes 100 .2 80 C 0 6G 0 40 Q. C, 0 2 4 6 8 10 12 14 16 18 20 14.0 13.0 Voltage 10 V LINEN INEUl• II, Final III 100110,1100 ___ I_N NONE__ E (68°F) 0 - ~ ~O f". (32°F) 100 120 100 80 0 0 200 400 600 800 1000 1200 Number of Cycles Discharge Depth 100% Discharge Discharge Depth 50°! Depth 30% Discharge Current 0.2C (Final Voltage 1.7V/Cell) Charge Current: 0.IC I Ambient Temperature: 20°C to 26°C (68°F to 77°F) I I I I I RP4 hhhhhhhhhhhhhhhhhhhh/'h/' : Shelf Life & Storage Discharge Characteristics Discharge Time vs. Discharge Current Float Charging Voltage 2.25 - 2.30 V/Cell 0 1 2 3 4 Years Life Characteristics in Cyclic Use 1.2 2.4 6 12 24 36481 2 4 6 810 20 40 mm •'I" h Discharge Time Life Characteristics in Stand-By Use I I I I Ambient Temperature 20C (68F) I 0.60 1.2 2.4 6.0 12 24 Discharge Current (A) I• -•- - MEMO Cycle Applications: Limit initial Current to 3.6A. Charge until battery voltage (under Charge) reaches 14.4 to 14.7 volts at 68°F(20°C). Hold at 14.4 to 14.7 volts until current drops to under 120mA. Battery is fully charged under these conditions, and charger should be disconnected or switched to 'float" voltage. "Float" or "Stand-Ely" Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to the Charger Selection Guide in our specification sheets for °C-Series Switch Mode Chargers" and "Transformer Type A and F Series". Please contact our Technical department for advice if you have difficulty in locating suitable models. Iorn - Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS). ISO certification, etc.. • ___ DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel: +1-619-661-2020 Tel: +1-619-661-2030 Tel: +1-619-661-2020 Tel: +1-650-364-5001 Fax: +1-619-661-3650 Fax: +1-619-661-3648 Fax: +1-619-661-3648 Fax: +1-650-366-3662 national-sales@power-sonic.com customer-service@power-sonic.com support@power-sonic.com battery@power-sonic.com CORPORATE OFFICE • 7550 Panasonic Way. San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650 0309 Im df-52417:c • B-90 I 80-Character LCD (2) FureLITeALarms Serial Annunciatr by Honeywell I Ii1iiiiui.r.flfTr'Jtj General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-805 may be connected to the ANN-BUS of each FACP. No programming is required, which saves time dur- ing system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4" square electrical box. Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KlT for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-80s can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 49°C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:211 MEA: 442-06-E The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. dt-52417:c • 05/22/09 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID 1\16mber) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*) Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 -2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. 6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power wiring are supervised and limited. BA+- Tell ANN-BUS Device MS-9050UD T83 12345678 FACP Wiring to ANN-BUS Device ORDERING OPTIONS: ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SBBOKIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. FireLite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Is0 00i We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 86111111111111111111 MMUFACTUMNI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— dt-52417:c • 05/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of 1 CATEGORY: 7120 --ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2HoneywelI.com DESIGN: Model ANN-80 and *ANN80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftVC operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division df-521 21:al • E-325 MMF.300(A) Series! MDF-300 Fire u1eALarms Addressable Monitor Modules by Honeywell P •.'- .. ___ General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4' [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. MMF-301 is a miniature monitor module (a mere 1.3 (3.302 cm) H x 2.75 (6.985 cm) W x 0.5' (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device it monitors. MMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF-300 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each mod- ule is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in existing systems. MMF-300 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class ocI ° 2 4 8 3 12 19 2 13 lENS fMMF3OOandMMF3O2 ONES LOOP ADDRESS 0 detail of MDF-300 - note S,O 4a',cvl1' 1 3E II )JIS 2, 2 4, 6, 8 only 6 "ones" addresses are 0, 5 11 ONES0 r LOOP A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300 OPERATION Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125' (5.398 cm) deep box. MMF-301 Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire FACP. No additional power required. df-521 21:al • 04/28/08 - Page 1 of 6 High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. 15 0 1 ADDRESS 0 11 4 LOOP 4 1 5 06 5 TENS ONES I! 11F. Fl I oH 11 w L( o 110 H iI Co The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The MMF-301 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules in exist- ing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, watertlow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301 OPERATION Each MMF-301 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). MMF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3 (3.302 cm) high x 2.75 (6.985 cm) wide x 0.65 (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. MMF-302 Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. 11 SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. MMF-302 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302 OPERATION Each MMF-302 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 cm) deep box. MDF.300 Dual Monitor Module The MDF-300 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides two Class B (Style B) IDC circuits ONLY Class A (Style D) IDC circuits are NOT supported in any application. MDF-300 SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). - Maximum operating current: 750 pA (LED flashing). Page 2 of 6— df-521 21:al • 04/28/08 Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x 2.125° (5.398 cm) deep. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S3705 FM Approved CSFM: 7300-0075-185 MEA: 72-01-E Product Line Information MMF-300: Monitor module. MMF-301: Monitor module, miniature. MMF-302: Monitor module, two-wire detectors MDF-300: Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. Architects'/Engineers' Specifications Specifications of these and all FireLite products are available from FireLite. © H 00 11 CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Face plate for MMF-300, MMF-302, and MDF-300 Mounting Diagrams for Standard-sized Modules df-521 21:al • 04/28/08 - Page 3 of 6 Wiring Diagrams The following wiring diagrams are included: MDF-300: Typical dual two-wire Style B initiating device circuit configuration. MMF-301: Typical two-wire Style B initiating device circuit configuration. MMF-300: Typical two-wire initiating circuit configuration, NFPA Style B. MMF-300: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. MMF-302: Interface two-wire conventional detectors, NFPA Style B. MMF-302: Interface two-wire conventional detectors, NFPA Style D. Applications with Conventional Detectors: Resetting Conventional Detectors Figure 1 MDF-300: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits (L&H,) each power-limited to TONext —) Device FROM Pane! 230 pA max, 12 VDC max. MONITOR or Previous Device 47K EOL MODULE Resistor Communication Line ELR-47K 32 VDC maximum. Twisted-pair is 97 TENS 2 recommended. 47K EOL All Shown wiring is supervised and power limited. Resistor ELR.47K L LOOP ADORES Connect modules to listed compatible Fire o 9 Lite control panels only. ANY NUMBER of UL Listed contact closure devices may be used. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. Install contact closure devices per manufacturer's installation instructions, 6522w01.wrnl Figure 2 MMF-301: Typical two-wire Style B initiating device circuit configuration. DEVICE NEXT BLACK IRED UL LISTED Compatible Miniature Monitor Module Control . 5789 10 56 789 4 ' Z)1112 3 Panel 2 13 2 101514 10 - VIOLET11 I 14YELLOW 47K EOL INCLUDED 96720wi,l .wwl Page 4 of 6— df-52121 al • 04/28/08 NOTE: Wiring Diagrams this Page: MMF-300 Connect modules to listed compatible FireLite control • Any number of UL-listed contact closure devices may be panels only, used. All wiring shown is supervised and power limited. • DO NOT MIX fire alarm initiating and supervisory devices Install contact closure devices per manufacturers installa- on the same circuit. tion instructions. Figure 3 MMF-300: Typical two-wire initiating circuit configuration, NFPA Style B. (—) TO Nex FROM Panel Device 1+ or Previous Initiating Device Circuit (+) MONITOR Device NFPA Style B. power limited:k" Communication Line 32 VDC maximum. Twisted-pair is recommended. 47K EOL Resistor ELR-47K 5 Os _ Communication Loss LOOP ADD— (optional connection for panels which support this feature) FUTURE FEATURE 6720wr2 wmt Figure 4 MMF-300: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. TO Next Device C—) FROM Panel or Previous MONITOR Device MODULE Communication Line 32 VDC maximum. Twisted-pair is recommended. EOL Resistor is internal at terminals 8 & 9 610 3 Communication Loss (optional connection for panels which support this feature) FUTURE FEATURE 6720wr3 wrnt df-52121 al • 04/28/08 — Page 5 of 6 NOTE: Wiring Diagrams this Page: MMF-302 and CRF-300 Connect modules to listed compatible control panels only. • Detectors must be UL listed compatible with module. Terminal wiring must be power limited. • Install detectors per manufacturers' installation instructions. DO NOT MIX fire alarm initiating and supervisory devices • Power to the interface module must be externally on the same circuit. switched to reset the detectors. An relay control module DO NOT LOOP wire under terminals. Break wire run to can be used to switch power from a standard power sup- provide supervision of connections. ply; see Figure 8 below. Figure 5 MMF-302: Interface two-wire conventional detectors, NFPA Style B. TO Next ±LL rLLi FROM Panel INTERFACE Device MODULE Communication Line c2 o 32 VDC maximum. Twisted-pair is recommended. 3.9K EOL Resistor (included) Listed Batter, Backup switched DC power supply. A2143-1O OOR -DRESS 0 TO Next Interface Module k.— Optional Branch Circuit Module supervises supply voltage and detector loop. 6720wir5.wrnf Figure 6 MMF-302: Interface two-wire conventional detectors, NFPA Style D. TO Next - - FROM Panel Device 1+) (+1 or Previous Device INTERFACE MODULE Communication Line 32 VDC maximum. Twisted-pair is recommended. + ( ) Listed Batter, Backup switched DC power supply. Optional Branch Circuit 0 TO Next Interface Module Module supervises supply voltage and detector loop. 6720Wi,e.Wrnf Figure 7 Applications with Conventional Detectors: Resetting detectors NOTE: To reset conventional detectors, externally switch off power to the interface module they are connected to. This example shows CRF-300 (see DF-52130). TO Next ___ I RELAY FROM Panel or Previous Device DC POWER SUPPLY (+1 Listed for Fire (—I Protection with Batter, Backup 'l1 _rIJI4001 [ciI co2 Communication Line 32 VDC maximum. Twisted-pair is recommended. 6720w1r7.wrn1 Fire-Lite® and LiteSpeed® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 93=11=1 We cannot cover all specific applications or anticipate all requirements. MCINEMIN I MANIFACT111111ING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6 of 6 - df-521 21 al • 04/28/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL F FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2@Honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interlace signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I!! Svsri 51 Nc)1c0 Selectable-Output Horns, Strobes, and Horn Strobes SpectrA lertV Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTROMe Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15, 15/75 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING LISTED APPROVED 34011 lchi,,ne,, horn strobes, horns) 3023972 S55 2 (strobes) MEA approved (indoor strobes) . 11 MEA452-0S-E tbiroe strobes) 7135-1633109 (horns, th,roe,) SpectrAlert Advance Specifications Genera) SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30, 75, 9S,110,115, 135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder, The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDT listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 41556 x 411/16 x 21/8-inch back box.The module shall also control two Style Y (class B) circuits or one Style 7 (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32F to 120F (0CC to 49CC) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8diameter x 2.5 high (173 mm diameter x 64 mm high) Wall-Mount Dimensions (including lens) 5.6"L x 4.7W x 2.5 D (142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6Th x4.7Wx 1.3D(142 mm Lxi 19 mm x 33 mm D) Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2) 5.9 Lx 5.0W x 2,2" D (151 mm Lx 128 mm W x 56 mm D) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 diameter x 2.2" high (180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions (sold as a pack) (TR-HS,TRW-HS) 5.7'L x 4.8W x 0.35"D (145 mm Lx 122 mm W x 9mm D) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, TRCW-HS) 69" diameter x 0.35 high (175 mm diameter x 9 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AOS-0395-007 UL Current Draw Data 1 ..I .,.'. I 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 DC Input 8-17.5 Volts 15 15175 16-33 Volts 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 lemporalLow 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low, 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 .....,:. 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data _I 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-temporal Low 75 75 81 81 88 84 96 92 Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 Coded Low 75 75 81 81 88 85 96 92 ,Settings 7, 8, and 9 are not available on 2-wire horn strobe. A05-0395-007 SDectrAlert Advance Dimensions 5. Wall-mount horn strobes Ceiling-mount horn strobes -------- — Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Wall Horn Strobes p2R 2-Wire Horn Strobe, Standard Cd5, Red P2RH 2-Wire Horn Strobe, High cd, Red P2W 2-Wire Horn Strobe, Standard cd, White Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, I-ugh cd, Red SCW Strobe, Standard cd, White P2WH 2-Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White P4R 4-Wire Horn Strobe, Standard cd, Red Horns P4RH 4-Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4-Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories SRt Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red SRHT Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White SW Strobe, Standard cd, White BBSC-2 Back Box Skirt, Ceiling, Red SWH Strobe, High cd, White BBSCW-2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR-HS Trim Ring, Wall, Red PC2R 2-Wire Horn Strobe, Standard cd, Red TRW-I-IS Trim Ring, Wall White PC2RH 2-Wire Horn Strobe, High cd, Red TRC-HS Trim Ring, Ceiling, Red PC2Wt 2-Wire Horn Strobe, Standard cd, White TRCW-HS Trim Ring, Ceiling, White PC2WH 2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White Notes: Add "-P" to model number for plain housing (no"FIRE"marking on cover), e.g., P29-P. t Add "-SP"to model number for"FUEGO" marking on cover, e.g., P2R-SP. 4 "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and its candela settings, "High cd refers to strobes that include] 35, 150, 177, and 185 candela settings. '''\ IIrJI9 mOos Sstero Sensor 1 3825 Ohio Avenue St. Charles, IL 60174 Prod—rpeofiosoorrr orhjeooto oharrge without notice ulor systemsensorcom for l 4%__ $ Phone: 800-SENSOR2. Fax: 630-371-6495 rrentprodootorforroockrdrrgtheIoterteroorrofthsdotsrheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0186 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135 *150, *177 *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA /BBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division HOEMSYWOM GENESIS SERIES t415iT3 Description: 14 AWG 2/C SQL FPLP-CL2P Compliance: UL Standards 13 & 1424; NEC Articles 725 & 760 Construction: Conductor 14 AWG Solid Bare Copper No. of Conductors 2 Insulation Type Plenum PVC Color BIk, Red Thickness 0.007" nom. Diameter 0.078" nom. Lay Length 3.0" nom. Jacket Type Plenum PVC Color Red Thickness 0.015" nom. Diameter 0.180" nom. Legend (Ink Print) HONEYWELL PIN 4513 2C14 3038058 (ETL) FPLP OR CUP C(ETL)US FT6 75C (RoHS) W/O# XXXXXX-XXXXXX XXXXFT DEVICE/ZONE A B C D E F 1 23456 789 Properties: Temperature Rating -20 to 75°C Operating Voltage 300 Volts max. Capacitance 32 pf/ft nom. Impedance 59 Ohms nom. DC Resistance 2.5 Ohms/M' at 20°C Flame Rating UL 910, NFPA 262, C(UL) FT6 REV A 09/01/10 OA GENESIS SERIES CABLE Description: 18 AWG 2/C SQL FPLP Compliance: UL Standard 1424; NEC Article 760 Construction: Conductor 18 AWG Solid Bare Copper No. of Conductors 2 Assembly Tubed jacket over twisted insulated conductors Insulation Type Plenum PVC Color BIk, Red Thickness 0.007" nom. Diameter 0.054" nom. Lay Length 1.75" nom. Jacket Type Plenum PVC Color Red Thickness 0.015" nom. Diameter 0.134" nom. Legend (Ink Print) HONEYWELL 18 AWG 2/C (ETL) FPLPICL2P 3038058 75C WIO# XXXXXX-XXX C(ETL) FIB XXXXFT DEVICE/Z0NEABC0EF123456789 Properties Temperature Rating -20 to 75 °C Operating Voltage 300 Volts max. Capacitance 24 pf/ft nom. Impedance 65 Ohms nom. DC Resistance 6.5 Ohms/M' at 20°C Flame Rating UL 910, CSA FT6 Honeywell GENESIS SERIES CABLE Construction: Conductor 18 AWG Solid Bare Copper No. of Conductors 4 Assembly Tubed jacket over untwisted insulated conductors Insulation Type Plenum PVC Color Bik, Red, Ylw, Gm Thickness 0.007" nom. Diameter 0.054" nom" Lay Length Straight Jacket Type Plenum PVC Color Red Thickness 0.015" nom. Diameter 0.156" nom. Legend (Ink Print) HONEYWELL 18 AWG 41C (ETL) FPLP/CL2P 3038058 75C WIO# XXXXXX-XXX C(ETL) FT6 XXXXFT DEVICE/ZONEABCDEFI23456789 Properties Temperature Rating -20 to 75 °C Operating Voltage 300 Volts max. Capacitance 24 pflft nom. Impedance 65 Ohms nom. DC Resistance 6.5 Ohms/M' at 20°C Flame Rating UL 910, CSA FT6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE M,44~ LISTING No. 7161-1487-.0100 Page 1 of I CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: GENESIS CABLE SYSTEM7701 95TH Street, Pleasant Prairie, WI 53158 Contact: Orville Allen (262) 947-0720 Fax (262) 947-0724 Email: orvillegenesiscable.com DESIGN: Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP, HDPE or LDPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp., Grade GA-91-84, GPT-45, GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, Type "FPL" and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SD355(A), SD355T(A) SD355R(A) Dhti*tIOt'*ri,' df-52384:b • E-160 8 FlreuTeALarms Smoke Detectors by Honeywell I ,.,....i Cnr I The SD355(A) and SD355T(A) addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire'Lite's Address- able Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (P/N RA100Z(A)). The SD355R is a remote test capable detector for use with D355PL or DNR(W) duct smoke detector hous- ings. Features SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 99 with MS-9200 series, and 01 - 159 with MS-9600 series. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0' (10.16 cm) octagonal box, or 4.0 (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA1 OOZ). SD355 with B350LP base SD355T with B35OLP base Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white LEXAN®. 5D355(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation 5D355(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0 (10.16 cm) square box with plaster ring. 4.0 (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class B) wiring. S0355R mounts in a D355PL or DNR(W) duct detector housing. df-52384:b.3/12/1O—Page 1 0f2 Operation Each SD355/T/R uses one of 99 possible addresses on the MS-9200 series and up to 318 (159 on each loop) on the MS- 9600 series Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The SD355/T/R addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) without sending an alarm level signal. Because of its unipolar chamber, the 5D355/T/R is approximately two times more responsive than most photo- electric sensors. This makes it a more stable detector. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-9200 series or MS-9600 series addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200 series or MS- 9600 series for record keeping. Specification Voltage range: 15 -32 VDC (peak). Standby current: 300 hA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 m/sec.) maximum. Diameter: 6.1° (15.5 cm) installed in B350LP base. Height: 2.1" (5.33 cm) installed in B350LP base. Weight: 3.60z. (102g). Operating temperature range: for S0355(A): 0°C to 49°C (32°F to 120°F); for SD355T(A): 0°C to 38°C (32°F to 100°F). 8D355R(A): installed in a DNR(W) -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing. Listings Listings and approvals below apply to the SD355(A) and SD355T(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed, file S1059. ULC Listed, file S1059. CSFM approved: file 7272-0075:194. MEA approved: file 243-02-E. FM approved. Product Line Information NOTE: "A" suffix indicates ULC-Listed model. S0355: Adressable photoelectric detector; B350LP base included. 5D355A: Sames as SD355 with ULC Listing (B350LPA base included). SD355T: Same as 5D355 but with thermal element; B350LP base included. SD355TA: Same as SD355T with ULC Listing (B350LPA base included). SD355R: Remote test capable addressable photoelectric detector for use with a D355PL or DNR(W) duct detector hous- ing. B350LP(A): Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0' (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB(A): Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0° (10.16 cm) square box with or without plaster ring, 4.0' (10.16 cm) octagonal box, or 3.5° (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5° (3.81 cm). B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). Diameter: 6.2' (15.75 cm). Mounting: 4.0° (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5° (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5° (3.81 cm). B200SR: Sounder base capable of producing temporal-3 or steady sound output. ACCESSORIES: RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B350LP(A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501(A) base only. RMK400: Recessed mounting kit. For use with B501(A) base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010:Detector removal tool without pole. BCK-200B: Black detector covers, box of 10. WCK-200B: White detector covers, box of 10. FlashScan® registered trademark of Honeywell International Inc. Bay- blend® is a registered trademark of Bayer Corporation. @2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. -b We cannot cover all specific applications or anticipate all requirements. MSINEENNI III MMUFACTUMNS All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 - df-52384:b • 3/12/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 2; FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING Nc. 7272-0075:0194 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Models 5D350, SD350T, 5D355, 5D355R*, 5D355T and AD355 photoelectric type smoke detectors. Model SD350T and SD355T has a 135F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVA..: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models 5D355 and SD355R* are also approved for installations inside Fire-Lite Duct Housing D355PL(CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-11-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division