Loading...
HomeMy WebLinkAbout1950 SILVERLEAF CR; ; FS000026; Permit10/20/2020 FS000026 Permit Data City of Carlsbad Fixed Systems Permit Permit No: FS000026 Status: ISSUED Applied 12/11/2000 Approved: 1/12/2001 Issued: 1/12/2001 Inspector: Job Address: 1950 SILVERLEAF CR Permit Type: FIXSYS Parcel No: Lot #: 0 Reference No.: PC #: Project Title: LA COSTA GLEN CONTINUING LIFE Applicant: Owner: Fees Add Fees ($ Tota I ($) Balance ($) 90 0 90 0 1/1 ALL INSTALLATION PROCEDURES ARE IN COMPLIANCE WITH ALL MANUFACTURERS SPECIFICATIONS AS OUTLINED IN NFPA 17A, 96, 1998 EDITION REMOTE PULL STATION IS MOUNTED NO HIGHER THAN 48" FROM FINISHED FLOOR SURFACE AND ON WAY TO EGRESS. PULL STATION CLEARLY STATES USE ON COVER PLATE. CONTROL HEAD ALSO OPERATES AS A PULL STATION AND INDICATES SYSTEM AS BEING 'SET' OR 'DISCHARGED'. ALL APPLIANCE NOZZLES TO BE INSTALLED BETWEEN MINIMUM DISTANCES FROM CENTER POINT OF SPECIFIED COOKING HAZARD AS PRESCRIBED IN MOST CURRENT MANUFACTURERS TECHNICAL MANUAL. ALL PLENUM NOZZLES SHALL BE INSTALLED AT THE MIDPOINT OF THE AREA THEY PROTECT AND NO FARTHER THAN 3' UP FROM BASE OF DUCT. ALL DUCT NOZZLES SHALL BE INSTALLED AT THE MIDPOINT OF THE AREA THEY PROTECT AND NO FARTHER THAN 8" UP FROM BASE OF DUCT. SYSTEM SHALL BE TIED INTO AND SUPERVISED BY BUILDING FIRE ALARM SYSTEM AND ACTIVATED GENERAL ALARM UPON DISCHARGE (IF APPLICABLE). AUTOMATIC FUEL SHUT-DOWN DEVICE(S) SHALL SHUT-DOWN ALL SOURCES OF FUEL, POWER AND HEAT TO PROTECTED EQUIPMENT AS REQUIRED. PROVIDE 2A 10 BC RATED PORTABLE FIRE EXTINGUISHER NEAR SEVICE COUNTER AREA IN AN EASILY ACCESSIBLE LOCATION. PROVIDE 40B:C OR K CLASS EXTINGUISHER NEAR PROTECTED COOKING EQUIPMENT BUT ON PATH OF EGRESS. (EXTINGUISHER AND LOCATION SUBJECT TO FIRE DEPARTMENT APPROVAL) SYSTEM TO BE TESTED-FIRED AND WITNESSED BY AUTHORITIES UPON COMPLETION AND PRIOR TO SYSTEM BEING PUT INTO SERVICE, TEST TO INCLUDE OPERATION OF REMOTE PULL STATION, LAST FUSIBLE LINK ON DETECTION ON LINE AND FUEL SHUT-OFF DEVICE. IT WILL BE THE SOLE RESPONSIBILIY OF THE RESTAURANT OWNER TO MAINTAIN AND SEVICE THE SYSTEM AS PRESCRIBED BY LOCAL AND STATED LAWS. ALL SUPPLY AIR SHALL SHUT-DOWN UPON ACTIVATION OF SYSTEM. ALL EXHAUST AIR SHALL REMAIN OPERATIONAL. IIY UI-CARLSBAD - FIRE DEPARTMENT APPROVED Subject to field inspection and reqia c tests, notations hereon, Condition, in Correspondence and Conformar 'e with applicable regulations The smping Of these plans shall not be; eld to pey or approve teviolaØn any law, BY J. Date i/z~500 REMOTE PULL STATION -EXIT 4 HOOD 2 MECH. GAS SHUTOFF VALVE ANSUL R102 12 GAL. SYSTEM FLOUR PLAN I SCOPE OF WORK: OSHPOD #992077-37 FACILITIES #99002 I CA CONTRACTOR'S LICENSE#555875 C-1 0, C-16 102-12GAL SYSTEM STATE FIRE MARSHAL LICENSE#A-0357 I NOT TO SCALE 011 NO., I FIRE EXTINGUISHING SYSTEM I CET,I CONTINUING LIFE COMMUNITIES LLC 10F4 I IZAWN BY' I 777-tIINOEE' L H R CARLSBAD, CA. 92009 COMMONS BUILDING ATE' IAPPROVED BYi 12-04-00 I ANSUL R102-12 GAL (c5oS,2/e 7& UL300 Fire Master A NATER PWTECTION CANY 4217 PONDEROSA AVE. STE.1 SAVOE6O, CA. 92123 (TEL) (858)569-3888 OD 1 23'6" EXHAUST HOOD ' 23'6" SINGLE-BANK PLENUM A 048 CHEESEMEL © © I A> TO 2-3 GAL. MANIFOLDED TANKS A I_B)TO2-3 GAL. MANIFOLDEDTANKS 91 I A © biB 0 60 CHEESEMELTER .® 01 I® 01 ® ® ® l ® 48X24" GRIDDLE 12XI I I I i ii II I j ® i ® I 48X 28 RANGE 48X20" GAS RAD. RANG FF CHARBROILER 14X15 NOZZLE SCHEDULE 1 4500 FUSIBLE LINKS I FRYERS # PARTNO. TYPE PIPESIZE FLOWS Q,TY. NOZZLEHEIGHT 'u.' 419335 1 1I'4 3/8" 1 3 2 1" TO 4" PLENUM COVERAGE 26" TO 40"BROILER COVERAGE © 419337 2W 3 /8" 2 2 2" TO 8" © 419339 230 3 / 8" 2 2 27" TO 47" ® 419340 245 3/8" 2 2 40" TO 50" ® 419334 1/2 N 3/8" 1/2 8 ABOVE & BELOW GRATE © 419341 260 3/8 " 2 1 0"TO50"(PERIMETERLOCATION 0 419333 1 F 3 / 8" 1 1 30" TO 50" THIS ANSUL R102-12 GALLON WET CHEMICAL SYSTEM USES 44 OUT OF 44 FLOWS AND COMPLIES WITH STANDARD UL300 THIS SIDE (HOOD 1) SHOWS 24 OUT OF 44 FLOWS CA. CONTRACTOR'S LICENSE 555875 0-10, 0-16 STATE FIRE MARSHAL LICENSE #A0357 BN0,' IFIRE EXTINGUISHING SYSTEM HEET-I CONTINUING LIFE COMMUNITIES LLC 20F4 I RAWN BY' 7707 EL CAM INO REAL COMMONS BUILDING L H R CARLSBAD, CA. 92009 ATE. 1APPRQVED BY' 1MrG. 12-04-00 I ANSUL R102-12 GAL (HOOD 1) 7 q) 5 -() 7 / ;~ 70 Fire Master A KASTER PROTECTU) CDANY 4217 PONDEROSA AVE. STE.1 - SAN DIEGO, CA. 92123 t (858)569-3855 )D 2 21 EXHAUST HOOD LJ A) TO 2-3 GAL MAN IFOLDED TANKS 21'SINGLE-BANK PLENU M A A B) TO 2-3 GAL MANIFOLDED TANKS © 0 NOZZLE SCHEDULE # PART NO. TYPE PIPE SIZE FLOWS QTY. NOZZLE HEIGHT O 419335 iN 3/8' 1 3 1"TO4" © 419337 2W 3/8" 2 2 2"TO8" © 419338 3N 3 /8" 3 3 c 25" TO ® 419340 245 3/8" 2 2 40" TO 50" 0 © 4500 FUSIBLE LINKS THIS ANSUL R102-12 GALLON WET CHEMICAL SYSTEM USES 44 OUT OF 44 FLOWS AND COMPLIES WITH STANDARD UL300 THIS SIDE (HOOD 2) SHOWS 20 OUT OF 44 FLOWS CA. CONTRACTOR'S LICENSE 555875 C-1 0, C-16 STATE FIRE MARSHAL LICENSE #A0357 3B NO., FIRE EXTINGUISHING SYSTEM IEET' CONTINUING LIFE COMMUNITIES LLC 3 OF 4 PAWN BY, 7707 EL CAMINO REAL COMMONS BUILDING L H R CARLSBAD, CA. 92009 ATE' I APPROVED BY,writ 12-04-00 ANSUL R102-12 GAL (HOOD 2) Fire Master A MASTER PROTECTUY CDU'NIY 4217 PONDEROSA AVE. STE..1 SAN DIEGO, CA. 92123 " (958)569-3888