HomeMy WebLinkAbout6914 TOURMALINE PL; BLDG 9; FA110027; Permit12/29/2020 FA110027 Permit Data City of Carlsbad Fire Alarm Permit 6914 TOURMALINE Job Address: PL Permit Type: FALARM Parcel No: 2131125101 Lot #: 0 Permit No: FA110027 Status: ISSUED Applied 3/28/2011 Approved: 3/28/2011 Reference No.: Issued: 3/28/2011 PC #: Inspector: Project Title: AVELLINO BLDG. 9 TWO FIRE ALARM INSPECTIONS @ $65/EA (CREDIT OF $105.00) Applicant: KPS SUITE A 760 S. ROCHESTER AV ONTARIO, CA 909-980-9222 Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 25 0 25 0 1/1 Project Avellino La Costa Building-9 69141 69161 6918,6920 Tourmaline Place Carlsbad, California Alarm system contractor 01(14 LIK3 760 S. Rochester Avenue, Suite A Ontario, Ca 91761 9091980-9222 St Lic. C-jO No803708 FA [ ~ () () 1 A['PRAt5 AS SUBilTTED 1 I ....-MS..5UD.3(E)/MS1OUD-1(E) - --.- Five Zone Fire Alarm Control Panel I ..-.. Ten Zone Fire Alarm Control Panel DF-52416:A- A3-20 FlrelffffAtarms by Honeywell I . General TTh MS5UD-3(E)-is a five-zone FACP (Fire -Alarm Control -- - :-- .. Panel) and the MS-10UD-7(E)ia ten-zone FACP. These con- trot panels provide reliable fire signaling protection for small to - dium-sizedcommercial,industriaf, and institutional build- - ings. Both panels include built-in communicators for Central Each of these FACPs is compatible with System Sensors V Station Service and remote upload/download. microprocessor-based i series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to -- - the-FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the IJIJiL detector rating. Additionally, both the MS-5UD-3 and MS- V 1OUD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow - devices, tamper switches, and other normally-open contact devices. Refer to Fire-Lite Device Compatibility Document-for- a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs - Optional CAC-5X Style Z (Class A) Converter Module for supervise all wiring, AC voltage, battery level and telephone- - NACs-and lDCs (2 required for MS-lOUD-i). line integrity. - Form-C Relays for Alarm, Trouble and Supervisory - Con- Activation of a compatible smoke detector or any normally- tact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive). open fire alarm initiating device will activate audible and visual - 3.0 A total system current for MS-5UD-3. signaling devices, illuminate an indicating LEO, sound the 7.0 A total system current for MS-i OUD-7. piezo sounder at the FACP, activate the comrunicator and FACP alarm relay, and operate an optional modiië-..used to Optional Dress Panel DP-51050. notify a [emote station or initiate an auxiliary control funètion. - Optional Trim Ring TR-CE for semi-flush mounting. The MS-5UD-3E and the MS-10UD-7E offer the same fea\ires 24 volt operation. - Low AC voltage sense. as the MS-5UD-3 and MS-10UD-7 but allow connectio\to 220/240 VAC. - Alarm Verification. NOTE: Unless otherwise specified, the information in this data - PAS (Positive Alarm Sequence). sheet applies to both the 110/120 VAC and the 220/240 VAC ver- sions of these panels. - Automatic battery trickle charger. - Optional 8 zone Relay Module ANN-RLY. Features - Optional Remote Annunciator ANN-SO. - Listed to UL Standard 864, 9th edition. - Optional Remote Printer Gateway ANN-S/PG. Built-in DACT (Digital Alarm Communicator/Transmitter) - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city . Style B,(Class B) lDC (Initiating Device Circuit)- - MS-5UD-3 five lDCs. box transmitter). - MS-10UD-7 - ten IDCs. PROGRAMMING AND SOFTWARE: . Style V (Class B) NAC (Notification Appliance Circuit) 7 spe- - Can be programmed at the panel with no special software cial application power or additional equipment. - MS-5UD-3 - four NACs. - Programmable Make/Break Ratio. - MS-lOUD-7 - four NACs. - Upload/Download (local or remote) of program and data via - Notification Appliances may be programmed as integral DACT. - Silence Inhibit. USER INTERFACE: - Auto-Silence. - Built-in DACT (Digital Alarm Communicator/Transmitter). - Strobe Synchronization for System Sensor, Wheelock, - Integral 80-character LCD display with backlighting and Gentex, Faraday, or Amseco devices, keypad. - Selective Silence (horn-strobe mute). - Real-time clock/calendar with automatic daylight savings - Temporal or Steady Signal. adjustments. - Silenceable or Nonsilenceable. - ANN-Bus for connection to remote annunciators. - ------- DF-52416:A- 06/18/07— Page 1014 SYSTEM SPECIFICATIONS System Capacity - Annunciators ......................................................................8 Electrical Specifications - MS-SUD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, iDA - MS-lOUD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.9 A MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50/60 HZ, 0.54 A MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50! 60 HZ, 2.2 A Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, rtonpower-limited Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82 (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00' (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00 (55.88 cm.) high x 19.65' (49.91 cm.) wide. Shipping Specifications Dimensions: 20.00(50.80cm.) high - 22.5' (57.15 cm.) wide —8.5(21.59cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49C/32 - 120SF and at a relative humidity 93% ± 2% RH (noncondensing) at 32C ± 2C (90F ± 3F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed nan environment with a normal room temperature of 15 - 27C/60 - 80F.. Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels.. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved CSFM: 7165-0075:214 NFPA Standards The MS-5UD-3(E)/MS-10UD-7(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual. Waterilow and Sprinkler Supervisory). - - AUXILIARY (Automatic, Manual and Watertlow) (requires - 4XTMF). - REMOTE STATION (Automatic, Manual and Waterfiow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble. 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterfiow). - CENTRAL STATION (Automatic, Manual and Waterfiow, and Sprinkler Supervised). FireUte® Alarms and System Sensor'S are registered trademarks of Hon- eywell International Inc. 02007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. - ISO ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. BMlNIIIW & MrAUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.flrelite.com Page 4 of 4— DF-52416:A - 06/18/07 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7165-0075:0214 .... . . Page 1 of 1 I CATEGORY 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) .... . . ..... -------- - LISTEE: FIRE-LITE ALARMS. INC., One Fire-Lite Place, Northford, CT 06472-1653 - - - - - - Contact Brian Reynolds (203) 484-7161 Fax (203) 484-7309 I Email: Brian.Reynolds2Honeyweli.com V - DESIGN: Model MS-5UD-3, MS-5UD-3E, MS-5U0-7, MS-5UD-7C, MS-5UD-7E, MS-10UD-3, MS-10UD-3E, MS-10UD-7, MS-10UD-7C AND MS10UD-7E Fire alarm control units. The I MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both --------------------. - .. -.... _... ._.-product lines have four notification appliance circuits, .and three relay contact outputs for - alarm, trouble and supervisory and include an integral two-line digital alarm communicator I transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The C" suffix represents products . that have the separately. listed ANN-LED annunciator module already installed. Refer. to .........,_.. ..- .. - l listee's data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF;Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. 04-23-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an P; endorsement or recommendation of the item listed. This listing should not be used to verify correct operational 4' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION - OFFICE OF THE STATE FIRE MARSHAL -. - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTINGNo. -. 7272-1653:0152 Page 1 of 1 CATEGORY 7272 PHOTOELECTRIC SMOKE DETECTOR LISTEE System Sensor Unincorporated Div of Honeywell Intl Inc.,3825 Ohio Ave St Charles IL 60174 - - Contact Trish Linhart (630) 377-6580 Ext 1185 - Email: trish.linhartsystemsensor.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and .2-B are 2-wire and model 4W-B and 4-B are 4-wire detectors. Models 2W1-13 and 4WT-B employ a thermistor type heat sensor (1350 F). The heat sensor is are ..... supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35VDC . I -INSTALLATION: -. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. .1 MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in ripen arèás*ithair vldcityranefrom 0-1000 ... ft/min. NOTE: Formerly 7272-1209:210 I 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an Ys endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO Program Coordinator Fire Engineering Division June 30, 2000 DF-52004 F-050 BG-12 Series FIreuTeeALarrns Manual Fire Alarm Pull Stations www.firelite.com Section: Conventional Initiating Devices I I I GENERAL The Fire-Lite BG-12 Series is a cost-effective, feature- packed, non-coded series of manual fire alarm pull sta- tions. It was designed to meet multiple applications with the installer and end-user in mind. The BG-1 2 Series fea- tures a variety of models including single- and dual-action versions. The BG-12 Series provides Fire-Lite Fire Alarm Control Panels (FACP5), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Eásili 6èFtëd (sitlTh dl-action )tdèsigd io- prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down posi- tion to clearly indicate the station has been operated. - The word "ACTIVATED" appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. Braille text included in finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patent-pending hex-lock needs only a quarter-turn to lock/unlock. Station can be opened for inspection and maintenance without initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and 'ACTIVATED' are molded into the plastic adjacent to the alarm switch (located inside). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head cap- tive 8/32 screws for easy connection to Initiating Device Circuit (IDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.25 mm2). Terminal numbers are molded into the backplate, elimi- nating the need for labels. California State Fire c®us Marshal 7150-0075:184 LISTED 9 (except BG-12LOB S711 < > APPROVED Switch contacts are normally open. Can be surface (with SIB-10) or semi-flush mounted. Semi-flush mount to a standard single-gang, double- gang, or 4' (10.16 cm) square electrical box. - Backplate is large enough to overlap a single-gang backbox cutout by up to 1/2 (12.7 mm). Optional trim ring (BG-TR). Spanish version (FUEGO) available (BG-12LSP). Designed to replace the popular BG-10 Series. Models packaged in attractive, clear plastic (PVC), clamshell-style, Point-of-Purchase packages. Packag- ing includes a cutaway dust/paint cover in shape of pull station. 1 1 I I This document is not intended to be used for installation purposes. We try to keep our1 product information up-to-date and accurate. We cannot cover all specific applica- tions or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, I =4 I I_..i Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX ININIERING &MANIJFACTIJRI LZ1 Back:(888) 388-3299. Made in the U.S.A. DF-52004--- Page 1 0f2 CONSTRUCTION PRODUCT LINE INFORMATION Cover, backplate and operation handle are all molded Model of durable polycarbonate material. - BG12S Cover features white lettering and trim. Red color matches System Sensor's popular BG-12 SpectrAlertTM horn/strobe series. OPERATION BG-12L Description Single-action pull station with igtaiiconñéc- tions, hex lock. Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock. Same as BG-12 with key lock. The BG-12 manual pull stations provide a textured finger- hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking per- sons. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bot- tom as a visible flag. Resetting the station is simple; in- sert the key or hex (model dependent), twist one quarter- turn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: BG-12 SB-10 Height. 5.500 inches 5.500 inches (13.97 cm) (13.97 cm) Width: 4.121 inches 4.125 inches (110.4673 cm) (10.4775 cm) Depth: 1.390 inches 1.375 inches (3.5306 cm) (3.4925 cm) Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating in- structions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching backbox SB-b; or semi- flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Sta- tions shall be Underwriters Laboratories listed. *NOTE. The words "FIRE/FUEGO" on the BG-12LSP shall appear on the front of the station in white letters, approximately 3/4" high. Page 2ot2 - DF-52004 BG-12LSP Same as BG-12L with English/Spanish (FIRE! FUEGO) labeling. BG-12LOB Same as BG-12L with "outdoor use" listing. Includes WBB outdoor backbox, and sealing gasket. (FM Pending) 1.390" (35.306) I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 1 - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC., ONE-FIRE-LITE PLACE, NORTHFORD, CT 06410 Contact: Brian Reynolds (203) 484-6124 Fax (203) 484-7309 I Email: Brian. Reynolds2@Honeywell.com DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LAO, I BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-12SL, UT-PSi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description I and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listees name, model number and UL label. APPROVAL: Listed as tire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when I installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for -----outdooruse-heninstal led -with Model 1AfBB-or—Wi0backbwc * These These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm I - This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I the test results and/or other data but does not make an independent verification of any claim s - T h i s l i s t i n g i s n o t a n endorsement or recommendation of the item listed. This listing should not be used to v e r i f y c o r r e c t o p e r a t i o n a l requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. I Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MI4TEO, Program Coordinator U Fire Engineering Division 1 PRODUCT DATA SHEET - . .- •... 1530 Shields Drive ... Waukeoan, IL 60085 . .............. Toll-Free (800323-9355 -HI PART NUMBER: 97814 DESCRIPTION: 14/2 SOLID FTFPLR ZIP CABLE COWSTR1JCTlOW:Thiscable consists of two barecopper conductors laid flat with-an integral insulation -- ' - and jacket. --.APPROVALS' _____ULStandard 1424, MEG Articles 760. . -- - -- — APPLICATION ,._.....Power Limited Fire Alarm Circuit Cable Intended for Riser Applications Construction Parameters: Conductor - Stranding - - -. Insulation Material Insulation Thickness Insulated Cable Dimensions Number of Conductors Approximate Cable Weight Flame Rating 14AWG Bare Copper Solid PVC 0.030 Worn. 0.124 x 0.253 Worn. 2 37.0 Lbst1M' Worn. UL 1666 Riser Flame Test - . Cable Cross-Section I Electrical Properties: Temperature Rating -20°C to 60°C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz #REF' .apacj.tance Between Conductors to Shield @ 1 KHz DC Resistance per Conductor @20°C . 4OiM'J6 ..............._______.._.__._ .........- ....... ............ Insulation/Jacket Colors V\fttite, Red (Other colors available for minimum order) Legend (Surface Ink Print) El 00315 * 14 AWG 21C (UL) TYPE FPLR SUN RES On special orders, the customer will accept at factory lengths and +1- 10 percent of total order requested. The jacket is sequentially frrolmarbed The information presented here is, to the best of our knowledge, true and accuraie. Since conditions of use are beyond Coleman cable's control, all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman cable or confer any rights on any customer. The sale of product(s) is conditioned upon acceptance of purchase order subject to Coleman cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims at liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual properly of Coleman cable. Any information contained herein shall not be disddsed to any patty without written consent of Coleman Cable. Customer Name________________________________________ Customer Approval Specification Issue Dale: December 27, 2005 I 1-800-323-9355 (Phone) - Designed By: PEP 1-847-689-1192 (Fax) 97814 tO 2005 Coleman Cabin, inc. I Fax: (847) 689-1192 I ,* I — deft PRODUCT DATA SHEET 1530 Shields Drive Waukegan IL 60085 - Toll-Free (800) 323-9355 -Fax: (847)689-1192 -- PART NUMBER: 98181 DESCRIPTION: 18/2 SOLID FPL FT1 MID-CAPACITANCE CABLE CONSTRUCTION: This cable consists of two bare copper insulated conductors with an overall jacket. : APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in General Purpose Applications for Addressable Fire Alarm Systems Construction Parameters: Cable Cross-Section Conductor 18 AWG Bare Copper Stranding Solid Insulation Material Polypropylene Insulation Thickness 0.006 Worn. Insulated Conductor Diameter 0.052 Nom. Number of Conductors 2 Lay Length 4.00 Worn. Separator/Wrap None Jacket Material PVC Jacket Thickness 0014 Norn Overall Cable Diameter 0.132' Worn. Approximate Cable Weight 16.0 Lbs/1M Worn. Flame Rating UL 1581 Vertical Tray Flame Test I Electrical Properties: Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz 19 pF/fl Worn. I Capacitance Between Conductors to Shield @ 1 KHz DC Resistance per Conductor @ 2dC 6.32 Ohms/1M Worn. I Insulation Colors Black Red Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) E100315 18 AWG 2/C (UL) TYPE FPL SUN RES -- C(UL) ' TYPE CM FT1 --ADDRESSABLE FIRE CABLE On special orders, the customer will accept all factory lengths and /- 10 percent of total order requested. The jacket is sequentially footmarired. I. The information presented here is, to the best of our knowledge, true and accurate. Since Conditions of use are beyond Coleman cables control, all product data presented i s f o r informational purposes only and does not create a binding obligation or liability on Coleman cable or confer any rights on any customer. The sate of product(s) is conditioned upon acceptance of purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard w a r r a n t y . C o l e m a n Cable disclaims all liability in connection with the use of information contained herein or otherwise. I This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. I Customer Name_ Customer Approval Specification Issue Date: December 27, 2005 1-800-323-9355 (Phone) Designed By: PEP 1-847-889-1192 (Fax) 98181 02005 Coleman Cable, Inc. I I I I I --J .- — .. . - — - - -. PRODUCT DATA SHEET 1530 Shields Drive Waukegan IL 60085 Toll-Free (800) 323-9355 -. Fax: (847) 689-1192 -. PART NUMBER: 51013 DESCRIPTION: 14 AWG STRANDED TYPE THHNITHWN FIXTURE WRE -- . CONSTRUCTION:--- -This cable consists of one bare copper conductor withintegrat insulation and jacket. APPROVALS: UL Standard 62 and Subject 758 APPLICATION: Fixture Wire, Appliance Wring Material, Canada TOO-Nylon, Canada TVl/N75 ----Construction Parameters: •••••COrid(Jct -. 14 AWG Bare Copper Stranding ' - 191.0147" .•• Insulation Material . . PVC/Nylon PVC Insulation Thickness 0.016" Worn. Nylon Insulation Thickness 0.005" Worn. Insulated Conductor Diameter 0.112' Worn. Number of Conductors 1 Approximate Cable Weight 16.4 Lbsl1M Worn. Electrical & Environmental Properties: Temperature Rating -20°C to 105°C Operating Voltage 600V Max Impedance 41.08 Ohms/1M' DC Resistance per Conductor @ 20°C 2.52 OhmsllM' Insulation Color Varies Legend (Surface Ink Print) BARON 14 AWG (UL) E101736 THHN OR THWN 600V GASOLINE & OIL RES I OR AWM STYLE 1316 & 1408— C(UL) T90 NYLON OR TWN75 FT1 On special orders, the customer will accept all mil lengths and *1- 10 percent of total order requested. -......... The infoation presented here is. to the best of our knowledge, tree and accurate. Since conditions of use are beyond Coleman cables control, all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sate of producitsl is corru3rtroned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise- This specification is proprietary intellectual property of Coleman cable. Any information contained herein shalt not be disclosed to any party wthout wnttencor sent of Coleman Cable. - Customer Name________________________________________ Customer Approval Specification Issue Date: October 24, 2005 I 1-800-323-9355 (Phone) 1-847-689-1192 (Fax) 51013 I Designed By: PEP 10 2005 Coleman Cable, Inc. - CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . . •. I.......... V. LISTING SERVICE LISTING No. 7161-1236:0102 . Page lot 1 I CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: COLEMAN CABLE SYSTEMS, 1530 Shields Dr, Waukegan, IL 60085 ——Contact Howard Caccia (847) 672-2000 Fax (847) 689-9116 . hgc@coleman-cable.com..... .. . . ... ...... - . . . . . - DESIGN: . Type FPL, FPLR and FPLP fire protective signaling cable. Refer to tistee's data sheet for detailed product description and operational considerations. - - I RATING: INSTALLATION: In accordance with tistee's printed installation instructions, NEC Art. 760 and applicable I codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type, NEC rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. I NOTE: Formerly 7161-0756:100 IL.::...........:. ............n.- .-.-. -.- - - -.-.....- . . . - - I........... . .. . V I 1 *Rev 06-15-05 I V V This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I the test results and/or other data but does not make an independent verification of any claims. This listing is not an 'j endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to tistee's data sheet, installation instructions and/or other suitable information sources. I Date Issued: July 01, 2010 Listing Expires June 30,2011 Authorized By: FRANCIS MATEO, Program Coordinator I Fire Engineering Division VSR-F I Jr ..i L T . .:VANE-WPEWATERFLOW . ALARM SWITCH WITH RETARD J UL, ULC and CSFM Listed, FM and LPC Approved, NYMEA Accepted Service Pressure: Upto450 PSI Minimum Flow Rate forAlarm: 10 GPM Maximum Surge: 18 FPS Contact Ratings: Two sets ofSPDT (Form C) 15.0 Amps at 125/25OVAC 2.0Ampsat30VDC Resistive Conduit Entrances Two knockouts provided-for l/2 conduit Environmental Specifications: - Suitable for indoororoutdoorusewith factory installed gasket and die-cast housing. NEMA4/IP54Rated Enclosure- use with appropriate conduit fitting Temperature Range: 40°F/120°F,4.5°C/49"C Non-corrosive sleeve factory insta lied insaddle Caution: This device is notintended forappl ications in explosive environments Si2ësAailabl6:....Ste0l PipscftedUles10thru40; sizes 2"-thru 8 BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 ServiceUse: Automatic Sprinkler One ortwo family dwelling Residential occupancy uptofourstories National FireAlarm Code Optional: Cover Tamper Switch Kit, Stock No. 0090018 NFPA-13 NFPA-13D NFPA-13R NFPA-72 GENERAL INFORMATION The Model VSR-F is a vaie type waterfiow switch for use on wet sprinkler systrns..Lt:iU_ Listed and FM Approved for use on steel th611Othiotigh 40, sizes 2"thru 8". - LP...approved sizes are2"thru8" (50mm thru 200mm). The Unit haisb be-used 'as a sectional waterfiow detector on large systems. ---The unit contains two single-pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. Th units should not be installed within 6" of a fitting which changes the direction of the watertlow or within 24" of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2 (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 11/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the watertlow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 905-882-1833" www.pottersignal.com PRINTED IN USA MKT. #8800001 - REV P PAGE 1 OF 2 MFG. #5400761 - 3/99 - CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION - - OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM I .... .LI STING SERVICE . . LISTING No 7770-0328:0001 Page 1 of 1 I CATEGORY. 7770 -- VALVES/SWITCHES . LISTEE: Potter Electric Signal Co, 1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595.-6731- Fax (314) 595-6797 . . I - ------ .Email: billw©potteisignal.corn_- ....-. . .........-- ............:....... . . DESIGN: Vane and pressure type water flow alarm switches Iis(ed below. Refer to listees data sheet -.for detailed product description and operational considerations. Vane Types: VSR-CF VSR-D VSR-FE-2 VS-SP VSR-SFT VSG VSR-C VSR-ST VSR-F VSR-SF VS-F VSR-SFG VSR VSR-S VSR-SG Pressure Type: WFS-13 WFSR-C WFSPD-B P510 PS-10A PS-bOA WFSR-F P5100 N: INSTALLATIO In accordance with liste&s printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL or FM label. APPROVAL: Listed as water-flow alarm switches for use with fire sprinkler systems. Vane models may be I used in wet pipe systems; pressure models may be used in wet or dry systems. Model ...............VSR-CF is for use on K, L or M copper pipe (2', 2-1/2", 3", 4") and listed CPVC pipe (2', 2-1/2', 3"). Model VSR-SF for use on 1", 1-1/4", 1-1/2" and "2" steel, copper or listed plastic pipe. l Model VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4", 1-1/2" and "2" plastic pipe. Models VS-F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2", 2-1/2", 3", 3-1/2", 4", 5", 6", 8" and 10" pipe. *Model VSR is for use on steel pipe sizes from 2" through 8". . Vne type switches may be used outdoors when the outdoor temperature never falls below I - 40oF. .. . Rev*5.172007 iw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division OSYSU-1 Stock No. 1010106 Stock- No. .1010206 . -. - OSYSU-17 -2 -- 1 -.............L I I OUTSIDE SCREW AND YOKE VALVE .---.-•,............. . ...,.. SUPERVISORY SWITCH I UL and CSFM Listed, FM Approved, N'{MEA Accepted Dimensions: 6.19"L X 2.25WX 5.88"H 15.7cm L X 5.7cm W X 14.6cm H Weight: 2 lbs. (.9 kg.) Enclosure: Cover - Die-Cast Finish - Red Spatter Enamel Base Die Cast Zinc All parts have corrosion resistant finishes Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: -40°Fto140F(0°Cto60°C)-.,--,... .................... NEMA 4 and NEMA 6P Enclosure (1P67) - Indoor or outdoor use (Not for use in hazardous locations. See Bulletin No. 5400705 OSYS-U-EX for hazardous locations). I Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use: 1 Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 - —GENERAL INFORMATION The OSYSU is used to monitor the open position of an additional cover screws and hex keys are available. See J & Y (outside screw and yoke) type gate valve. This ordering information on page 4. - device is available in two models; the OSYSU-1, con- OPTIONAL COVER TAMPER SWITCH taming one set of SPDT (Form C) contacts and the A field installable cover tamper switch is available as an ......OSYSU-2, containing two sets of SPDT (Form C) option which may be used to indicate removal of the contacts. These switches mount conveniently to most cover. See ordering information on page 4. OS & Y valves ranging in size from 2" to 12". They will mount on some valves as small as 1/2. TESTING The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or The OSYSU and its associated protective monitoring system should be inspected and tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently) Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 Phone: 800-325-3936/Canada 905-882-1833 1 www.pottersignal.com PRINTEDINUSA MKr.#8820004-REVM PAGE 1 OF 4 6/99 I I - . CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - - BUILDING MATERIALS LISTING PROGRAM I . LISTING SERVICE .......... LISTING No. 7770-0328:0010 Page 1 of 1 I . CATEGORY 7770--VALVES/SWITCHES . . . . LISTEE: Potter Electric Signal Co, 1609 Park 370 Place, Hazelwood, MO 63042 I Contact: Bill Witherspoon (314) 55-6731 Fax (314) 595-6797 .: -. - Email: billw@pottersignal.com . - .................... DESIGN: Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, PIV, tank. temperature or water level valves. Refer to Iistee's data sheet for detailed product I description and operational considerations: ................._._ HLS-B WLS-W WLS-S PS-40A I PS120A OSYSU-2 OSYS-B PMS PTS-B 0SYSU-1 GVS PCVS-1 PIVS-B TTS-S TTS-W PCVS-2 WLS PTS-C .PS40 PS120 . . ........ - . - ... .... I . *RBVS . . ... RATING: - :. : . ... INSTALLATION: n accordance with listee's printed instructions, applicable codes and ordinances and in a I ......................... maonr.a.cpta.bie to the authority having jurisdichon. . -. MARKING: Listee's name model designation and FM or UL label. I . APPROVAL: Listed as sprinkler system supervisory switches. . . ..... NOTE: Formerly 7738-0328:010 I -. ..............-.-- ........-.--- . . 1 I...... - . I....ii...............- .....-: - . I .5his listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed .,--..---.-,,--. I the test results and/or other data but does not make an independent verification of any claims. This listing is not an —endorsement oc r cn .ecomendation of the tern lisied This listing should not re be- used to venfy-corc -cp.erationaL.._. -- c-i' _cequirements or installation criteria. Refer to listees data sheet installation intructioris and/.o.o1het_..suit.able information sources. I D.atelssJed .JuIi 0'l, 2010 -stIng_Expies5 =Juri3o 20f1___iiiiiiiIIII.. Authorized By: FRANCIS MATEO, Program Coordinator .........- . .. ..: 1 . Fire Engineering Division . . -. . - ........ FAUOôZ Fire Alarm System -Certificate of Completion This form must be completed and available to the lire inspector upon their arrival to conduct a final fire alarm system performance test. Location of Fire Alarm System Name: Avellino La Costa 9 Address: 6914,6916. 6918,6920 tourmaline Place City/State/Zip;Carisbad.CA 92009 Telephone Contact: t;cneral Information: Alaim Panel Manufacturer: Firelite Alarm System Installer Name: J(PS PowcThMnc Address: 760 S. Rochester Ave. Suite 13 CityiSate/Zip: Ontario, CA 91761 - Telephone II; 909-980-9222 Contact: Service i)epartnient Model: FLMS5VD-3 Aiann Panel Location; Outside of Electrical Closet Elect Panel Name /# House Panel HP Circuit No.: #4 SPRINKIEK SYSTEMS Inspectors Test Valve Location: Left of Front Door Time of Opening of Test Valve it, Alarm: .44 Seconds Main Drain Test ?)ate; N/A Static Pressurc N/A Psi Residual Pressure (Hn.ing): N/A PSI Normal Operating Pressure ulSystem: N/A PSI Date of Last Fire Pump Test if Applicable): N/A P1 Alarm And Detection Equipment Fire Alarm Control Panel YEN NO N/A A. Does the panel indicate normal conditions? B. Are all indicating lamps in wottin order? C. Does the trouble light operate? I), l)oes the silence switch operate? E. Does the panel have 8anciy Backup? F Are the Batteries properly charred? G Does the patiel have Zone l)isahie Capabilities? DEVICES QTY. QTY. TESTED CLEANED OK R note :nnunciators Zones Manual Pull Stations A. Coded H. Non-Coded X 5, Detectors 1 A_PhoLo.lutt1L I I X C Thermal D Flame E.__Duct F. Rate o1 Rise G. Fixed _Temperature 6. Audible Maims A Bell B. Siren C.l1tw D. Horn & Strobe 7. Water Flow Switches A. Paddle Tpc -I j X B.Press tire Tvpc S.TuTuper Switches A.O.S.&V I x H._P.I.V, 9. Mod Sstem us.Kno Box x x x x Comments: - Did the Alarm Monitoring Company Receive the Signal? JYes 0 No Date: 11103/2010 Time: 0400 P.M. Is the Alarm System Back In Service: 1 Yes 0 No ALARM INSTALLER CERTIFICATION Reno Rask , representing the Firm KPS PowerHome have installed the Fire Alarm System at the location detailed above in accordance with the approved plans and have tested the system in accordance with the manufacturer's specifications and appropriate NFPA requirements and Local Ordinances. Alarm Installer: 'I '4IIL Date: P3