Loading...
HomeMy WebLinkAbout6305 EL CAMINO REAL; BLDG 6; FA070083; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA070083 6305 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 2130502200 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 11/16/2007 Approved: 11/19/2007 Issued: 11/19/2007 Inspector: Project Title: VIASAT - BLDG 6 TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: Owner: JJJ ENTERPRISES FIRST INDUSTRIAL L P C/O 1ST INDUSTRIAL REALTY TR INC 533 S VINEWOOD ST 898 N SEPULVEDA BLVD #750 ESCONDIDO CA EL SEGUNDO CA 760-747-3050 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 ow AdP'~'. I1H Fk~nc)93 NT EUIS S FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS Ihei pl:lll' hi' eii FVI'Ss ol hit L11111aleilt cit )PI titce stilt Ii it cut ipplisihi ssls and staisiltiuls in lots iii lw ii its Ii uses' iirsucititraclOr ina titiliie ot all application lot a hiuiIilitt p iii sib he e\prsss under,landing 111a, this ievte't o cc lies es the owner or con I ractor or their ,kssiiifltil engi UCCI II architect for sole responsihi liv hill s-silipliaiice with said codes and standards. liii. luding 11w N111(blig C(XIC or for any ft5)ttfl5Ihtlty for tic hi li.itiitS errors. ilflilsSlofl5 or negligence in these plitt, whether or not noted in this review. Date: II//f/c.7 Reviewer: RECOMMEND APPROVAL 0 KMltstENLl) APPROVAL AS NOTED VIASAT BLDG. #6 6305 EL CAMINO REAL CARLSBAD, CA 92009 FIRE ALARM SYSTEM Attention: CAT 45 key /locksets are to be installed on all Cabinets and Appliances utilizing cam locks. APPROVE D J SPUBMITTED CARLSBArR1RTMENT h9LE IUPY VIASAT BLDG #6 6305 EL CAMINO REAL CARLSBAD, CA 92009 BILL OF MATERIALS NOTIFIER NFS-640 INTELLIGENT ADDRESSABLE FIRE ALARM SYSTEM CSFM# 7165-0028:214 NOTIFIER FDU-80 CHARACTER DISPLAY ANNUNCIATOR CSFM# 7120-0028:209 NOTIFIER NBG-I2LX ADDRESSABLE MANUAL PULL STATION CSFM# 7150-0028:199 NOTIFIER FSP-851 WITH B7IOLP BASE INTELLIGENT SMOKE DETECTOR CSFM# 7272-0028:206 NOTIFIER FMM-1 MONITOR MINI MODULE WITH FLASHSCAN CSFM# 7300-0028:202 NOTIFIER FRM-1 ADDRESSABLE RELAY MODULE CSFM# 7300-0028:202 NOTIFIER FCPS-24S6 REMOTE POWER SUPPLIES CSFM# 7315-0028:225 NOTIFIER UDACT UNIVERSAL DIGITAL ALARM COMMUNICATOR TRANS CSFM# 7300-0028:174 NOTIFIER AS24, MCC WHEELOCK HORN/STROBE MULTI CANDELA CSFM# 7125-0785:131 NOTIFIER RSS24, MCC WHEELOCK STROBE MULTI CANDELA CSFM# 7125-0785:141 NOTIFIER RSSWP, 24MCW WEATHERPROOF MULTI CANDELA STROBE CSFM# 7300-0785:154 NOTIFIER ASWP, 24MCW WEATHERPROOF HORN/STROBE CSFM# 7125-0785:131 NFS-640 shown in CAB-1314 with NCA 640-character display. Powerful Boolean logic equations. NCA 640-CHARACTER DISPLAY FEATURES: Backlit, 640-character display. Supports SCS Series smoke control system in both HVAC or FSCS modes (not UL-Listed for FSCS). Printer and CRT ElA-232 ports. ElA-485 annunciator and terminal mode ports. Alarm, Trouble, Supervisory, and Security relays. FLASHSCAN® INTELLIGENT FEATURES: Poll 318 devices in less than two seconds. Activate up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Wa k Test. Fully digital, high-precision protocol (U.S. Patent 5.539,389). Manual sensitivity adjustment - nine levels. Pre-alarm intelligent sensing - nine levels. Day/Night automatic sensitivity adjustment. Sensitivity windows: - Ion - 0.5 to 2.5%/foot obscuration. - Photo - 0.5 to 2.35%/foot obscuration. - Laser (VIEW®) —0.02 to 2.0%/foot obscuraticn. - Acclimate P!USTM - 0.5 to 4.0%/foot obscuration. - HARSHTM - 0.5 to 2.35%/foot obscuration. Drift compensation (U.S. Patent 5,764,142). Degraded mode - in the unlikely event that the CPU-640 microprocessor fails, FlashScan® detectors revert to degraded operation and can activate the CPU-340 NAC cir- cuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. DN-6356:A • A-30 NFS.640 NOTI F E R® Intelligent Addressable Q) Fire Alarm System by Honeywell General The NFS-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. As a stand-alone small-to-large system, or as a large network, the ONYX® Series of products meets virtually every application requirement. Designed with modularity and for ease of system planning, the NFS-640 can be configured with just a few devices for small building applications, or for a large campus or high-rise applica- tion. Simply add additional peripheral equipment to suit the application. Features One, expandable to two, isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7. Up to 159 detectors (any mix of ion, photo, thermal, or multi- sensor) and 159 modules (NO. manual stations, two-wire smoke, notification, or relay) per SLC. 318 devices per loop! 636 per FACP or network node. Standard 80-character display, 640-character large display, or display-less (a node on a network). Network option - 103 nodes supported (NFS-640, NCA Net- work Annunciator, or NCS Network Control Station) using wire or fiber-optic connections. 6.0 amp switch mode power supply with four Class A/B built- in Notification Appliance Circuits (NAC). Selectable System Sensor strobe synchronization. io • Built-in Alarm, Trouble, and Supervisory relays. Up to 64 output circuits per FACP or network node; circuits configurable online. VeriFire® Tools offline program option. Sort Maintenance Reports by compensation value (dirty detector), peak alarm value, or address. Autoprogramming and Walk Test reports. Optional universal 636-point DACT. 80-character remote annunciators (up to 32). EIA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column printers). History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. Alarm Verification selection per point, with tally. Autoprogramming and Walk Test reports. Positive Alarm Sequence (PAS) Presigrial. Silence inhibit and Auto Silence timer options. March time / temporal / California two-stage coding / strobe synchronization. Field-programmable on panel or on PC, with VeriFire® Tools program check, compare, simulate. Full QWERTY keypad. Charger for up to 90 hours of standby power. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Automatic time control functions, with holiday exceptions. Surface Mount Technology (SMT) electronics. Extensive, built-in transient protection. - DN-6856:A • 12/01/C€ - Page 1 of 9 Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing. Maintenance alert (two levels). Self-optimizing pre-alarm. VIEW® (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY: Revolutionary spot laser design. Advanced intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the fire location. No moving parts to fail or filters to change. Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. ACCLIMATE PLUSTM LOW-PROFILE INTELLIGENT MULTI-SENSOR: Detector automatically adjusts sensitivity levels without oper- ator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. FlashScan® or classic mode compatible with NFS-640. Low-temperature warning signal at 40°F ± 5°F (4.44°C ± 2.77°C). HARSHTM HOSTILE-AREA SMOKE HEAD: Provides early warning of smoke detection in environment where traditional smoke detectors are not practical. The detectors filters remove particulates down to 30 microns in size. Intake fan draws air into photo chamber, while airborne parti- cles and water mist are removed. Requires auxiliary 24 VDC from system or remote power supply. RELEASING FEATURES: Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). Low-pressure CO2 listed. VOICE AND TELEPHONE FEATURES: Solid state message generation. Hard-wired voice control module options. Firefighter telephone option. 30- to 120-watt high-efficiency amplifiers (AA Series). Backup tone generator and amplifier option. Multichannel voice transponder (XPlQ). HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 AMP POWER SUPPLY (6.0 A IN ALARM): 120 or 220/240 VAC. Displays battery current/voltage on panel (with display). FlashScan® Exclusive World-Leading Detector Pro- tocol At the heart of the NFS-640 is a set of detection devices and device protocol - FlashScan® (U.S. Patent 5,539,389). Flash- Scan® is an all-digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high SLC Intelligent Loop I Up to 32 I L JRemote L - 1-_ eee r1-i DSPISYS 5lAcchmate DEVICES - i'RFX n jFXI FSL-751 FlashScan® VIEW® / FSH-751 FlashScas® HARSH NBG-12LX FMM-1 FSP-851 FlashScan® photo . FRM-1 4, XP5 Series, XPIQ P/11O I/O es oo etc. LB j p LB SLC Intelligent Loop 2 IDC Relay Contact F- 5817CB S751 LBE00 I LCD8O FDU80 LCD80 DEVICES EIA -485 FSP 851 FSI 851 F51851 Photo Ion Thermal — — — — — — — NBG-12LX FMM-1 FCM-1 XPS-M XP5-C XPIQ KDM-2 display EIA ff Ell, 2048 annunciator/control points I I IF: LE 1171:1 OR with no display 4 !! ACM-8R ACM/AEM-24AT LDM-32 Relay Control LED Annunciator Custom Graphics Up to 64 fully programmable +- Optional 636 point UDACT Dual phone output circuits 4—, I I lines to 4- L....... I Central [ EIA-232 Terminal Station Sample System Options NFS-640 EIA 232 /JT1\ shown in CAB C4 with KDM 2 and voice alarm system PAN Printer CRT-2 Terminal Page 2 of 9— DN-6856:A • 12/01/06 speed also allows the NFS-640 to have the largest device per loop capacity in the industry —318 points — yet every input and output device is sampled in less than two seconds. The micro- processor-based FlashScan® detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. Intelligent Sensing Intelligent sensing is a set of software algorithms that provide the NFS-640 with industry-leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the very- high-speed microcomputer used by the NFS-640. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value, usually indicative of a hardware problem in the detector; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre- alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self- restoring, and can be used to activate special control functions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of this intelligent sensing is the ability of a smoke sensor to con- sider readings from nearby sensors in making alarm or pre- alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature of the NFS-640. It is a special software routine that allows the NFS-640 to "learn" what devices are physically connected and automatically load them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installation, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-2) The NFS-640, like all NOTIFIER intelligent panels, has the exclusive feature of pro- gram creation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS-640 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS-640 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an off line programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Windows® based and provides technologically advanced capabilities to aid the installer. The installer may create the entire program for the NFS-640 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. EP G OR AT PASSWORD, THEN ENTER 0CLR 1- AUTO 2-POINT 3=PASSWORD 4-MESSAGE j Above: Keypad program editing. Below: Autoprogram function. AUTOPROGRAM PLEASE WAIT 11:80 DETS, 15 MODS L2.93 DETS, 35 MODS PANEL OUTPUTS:24 BELLS: 04 __•o__J r rm1flrt,nnr ,,. - - .- ' -, r-'- __- = I I — I±Ild,I flI I VeriFire ToolsSystem Programming screen DN-6856:A • 12/01/06 — Page 3 of 9 TOP, LEFT to RIGHT: J8 Zone Code Input; TB7 DC Power (24 VDC power-limited, both resettable and non-resettable available); T138 Alarm Relay; T139 Trouble Relay; TBIO Supervisory Relay; TBII Security Relay; SWI, SW5 Relay Switches; JPI3 General Board Earth Fault Jumper; TBI2 EIA-485 Terminal Mode (supervised); TBI3 EIA-485 ACS Mode (supervised); TBI4 EIA-232 Printer; TBI5 ElA-232 PC Terminal; JI NUP (network/service connection: power-limited, supervised); TBI6 SLC #1 Connections (detectors, modules; supervised); 055 Main SLC Ground Fault LED; JP7 Charger Disable Jumper; JPI2 200MA Jumper; JP6 Earth Fault Jumper (SLC #1). J8 187 T88 TBQ IBiD 1811 T812 1813 1814 1815 1816 186 :1-85 TB4 183 Disable/Enable Switches for NAC Circuit l7 Degraded Mode behind display 1B2 TB1 054; o r °SW5 D55 JP6 NAC LEDs 1 JlLj T5 4 3 also) ( JPI3 behind display 00 0 0—st JP12 JP7 behind display L IIiIiI_Iilii CPU-640 shown with [ ENWED FIRE EWN NEWEV [j ALARM TROUBLE SILENCED DISABLED KDM-2 Display SD El. ° 072 DB2D J3 I ii1H us ill \ /' --------------- Control Switches SW2.\ / J4. J5. J6 behind disolav \ SW3, SW4; and System Status Indicator LEDs (for "No-Keyboard Operation) behind display LEFT SIDE, TOP to BOTTOM: TB6 NAC #1, T135 NAC #2, TB4 NAC #3, T133 NAC #4 (all NAC circuits power-limited and supervised, and each NAC TB has an NAC LED to the right of it); J7 Accessory Power; Disable/Enable Switches for Degraded Mode; TB2 AC Power Connection; TBI Battery Connection (overcurrent protected). BOTTOM, LEFT to RIGHT: D54 AC On LED; System Status Indicator LEDs for "No-Keyboard Operation"; System Switches SW2 (Acknowledge), SW3 (Silence), SW4 (Reset) for "No-Keyboard Operation"; J4 KDM-2 Connector; J5, J6 Panel Circuits (ONYX® Panel Output Modules, supervised); D72 General Board Ground Fault LED; J1 Security Tamper Switch; Jil Auxiliary Trouble Input; D82 AC Power LED; J3 LEM-320 Connector (SLC Loop #2). Network Diagram RPT NCS RPT Block Diagram 24V -WF NOTI•FIRE•NETTM ACS PRN NFS-640 Sample j Node Configurations K H PRN . c>c<>c>c>c> NFN Twisted-Pair Wire NFN Dual Fiber-Optic Link LCD-80 Other Interfaces I ~RN ACS Style 7 YPIO XP _CD PRN NCA - speakers speakers phones phones ACS Page 4 of 9— DN-6856:A • 12/01/06 Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS-640's flexible system design. Rows: The first row of equipment in the cabinet mounts in chassis CHS-M2. Mount the second, third, or fourth rows of equipment in chassis CHS-4MB (see NFS-640 Installation Man- ual regarding panel output modules) or CHS-4L (for voice com- ponents, see Voice Alarm System Manual). Wiring: When designing the cabinet layout, consider separa- tion of power-limited and non-power-limited wiring as discussed in the NFS-640 Installation Manual. Positions: A chassis offers four basic side-by-side positions for components; the number of modules that can be mounted in each position depends on the chassis model and the size of the individual module. There are a variety of standoffs and hardware items available for different combinations and configurations of components. It is critical that all mounting holes of the NFS-640 are secured with a screw or standoff to ensure continuity of Earth Ground. Layers: The CHS-M2 accepts four layers of equipment, includ- ing the control panel. The CPU-640 fills three positions (left to right) in the first-installed layer (the back of the chassis); its inte- gral power supply occupies (the left) two positions in the next two layers; the optional display occupies (the left) two positions at the front, flush with the door. Panel output modules can be mounted in several layers with standoffs or an L-bracket as required. Some equipment, such as the NCA, may be door- mounted directly in front of the control panel. The NCA mounts onto the DP-DlSP or ADP-413. The NCA can be used as a pri- mary display for the NFS-640 by directly connecting their net- work ports (required in Canadian stand-alone applications). Expansion: Installing an LEM-320 Loop Expander Module adds a second SLC loop to the control panel. The LEM-320 is mounted onto the CPU-640, occupying the middle-right, second (back) slot on the chassis. If networking two or more control panels, each unit requires a NCM-W (wire) or NCM-F (fiber) Network Control Module. The NCM-W/-F can be installed in any panel output module position (see manual); the default position is at the back of the chassis next to the control panel. Option boards can be mounted in front of the LEM-320 or NCM mod- ules; for ease of access, complete installation of those devices before mounting another layer. CHS-M2 CPU-640 KDM-2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout). 8 LED indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled. Membrane Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED back- light. Configuration Guidelines Stand-alone and network systems require a main display. On single-CPU systems (one CPU-640/-640E), display options are the KDM-2 or the NCA. On network systems (two or more CPU- 640/-640Es), at least one NCA or NCS annunciation device is required. Other options listed as follows: KDM-2: 80-character backlit LCD display with QWERTY pro- gramming and control keypad. Order two BMP-1 blank modules and DP-DISP mounting plate separately. Requires top row of a cabinet. Required for each stand-alone 80-character display system. The KDM-2 may mount in network nodes to display "local" node information as long as at least one NCA or NCS network display is on the system to display network information. NCA: Network Control Annunciator, 640 characters. On single CPU-640/-640E systems, the NCA is the Primary Display for the panel and connects directly to the CPU-640/-640E. On network systems (two or more CPU-640/-640Es), one network display (either NCA or NCS) is required for every system. On network systems, the NCA connects (and requires) an NCM network communications module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP- DISP, ADP-413, or in an annunciator box, such as the ABS-2D. In CAB-4 top-row applications, a DP-DISP and two BMP-1 blank modules are required for mounting. See NCA data sheet DN- 6858. CPU-640: Central processing unit with integral 3.0 amp (6.0 A in alarm) power supply for an NFS-640 system. Includes CPU; one Signaling Line Circuit expandable to two; installation, pro- gramming and operating manuals. Order one per system or as necessary (up to 103 network nodes) on a network system. CPU-640E: Same as CPU-640 but requires 220 VAC, 1.5 amp, (3.0 A in alarm). Integral power supply Mounting location for LEM-320 tj KDM-2 shown with dress plate, or NCA at front, flush with door. Typical mounting location for NCM or TM-4 Panel output module mounted on L-bracket in front of control panel Available mounting slots for panel output modules DN-6856:A • 12/01/06 - Page 5 of 9 CHS-M2: Mounting chassis for CPU-640. One required for each CPU-640/-640E. DP-DISP: Dress panel for top row in cabinet with CPU-640/- 640E installed. BMP-1: Blank module for unused module positions. System Modules The NFS-640 includes the ability to communicate with up to eight conventional modules each with up to eight circuits. Any mix of notification, relay, speaker, or telephone may be used. Choose any combination of up to eight output modules: 1CM! ICE, CRM/CRE, DCM-4 or VCM/VCE. Panel modules mount on either: the two far-right positions of the DP-DISP (next to the pri- mary display); or on any of the four positions on the CHS-4N chassis (CHS-4MN kit required). NOTES: 1) These modules/expanders are NOT to be used for releasing applications. 2) For additional information on these panel output modules and expanders, see data sheet DN-6859. CHS-4MB: Expansion Chassis. Mounts up to four modules. Includes CHS-4N, MP-1 B (Module Dress Panel), and Expander Ribbon Cable. ICM-4RK: Notification Appliance Circuit Module, provides four Style Y (Class B) or Style Z (Class A) alarm Notification Appli- ance Circuits. Maximum signaling current is 3.0 amps per circuit or 6.0 amps per module, subject to power supply limitations (includes auxiliary power harness, ELRs and slide-in labels). Includes ON/OFF controls and ON/OFF LEDs. ICE-4: Notification Appliance Circuit Expander, expands ICM-4 to provide a total of eight Style Y or Style Z alarm Notification Appliance Circuits. Circuit ratings are same as ICM-4. NOTE: Maximum of one per ICM-4RK. May also be used to add four Notification Appliance Circuits to VCM-4. CRM-4RK: Control Relay Module, four Form-C relay contacts, rated at 5.0 A, 120 VAC or 28 VDC (resistive) per circuit. Includes manual ON/OFF controls and LEDs. CRE-4: Control Relay Expander, expands CRM-4 to provide a total of eight Form-C relay contacts. Note: maximum of one per CRM-4RK. May also be connected to add four relays to ICM-4, TCM-2, TCM-4, or VCM-4. VCM-4RK: Voice Control Module provides four Style Y (25 and 70 Vrms) and Style Z (25 Vrms only) speaker circuits, eight manual select switches and indicators, slide-in labels, and plug- in terminal blocks. Move jumper to convert to telephone circuits with remote ring signal and local call-in flash. May be expanded to eight circuits with VCE-4, ICE-4, or CRE-4. VCE-4: Voice Control Expander adds four circuits to VCM-4. Note: VCM-4/ VCE-4 combination must be eight speaker or eight phone circuits. DCM-4RK: Dual Channel Module pro-vides four Class B (Style Y, 25 & 70 Vrms) or Class A (Style Z, 25 Vrms only) speaker cir- cuits plus four channel NB select relays. Not expandable. OTHER OPTION MODULES ARM-4: Auxiliary Relay Module, four Form-C relays controlled by a relay module (CRM-4 or CRE-4). N.O. contacts rated 20 amps; N.C. contacts rated 10 amps at 125 VAC and 30 VDC. NOTE: Maximum of one for each CRM-4 or CRE-4. VCC-113: Voice Control Center. Provides a variety of user- selectable tones on a single channel. Up to two different tones or messages may be selected on a single channel. Also pro- vides optional digital voice message capability and on-site pro- grammable voice messages. Includes Audio Message Generator (AMG-1) microphone, cables, dress panels, and instructions. VTCC-1B: Voice/Telephone Control Center. Provides all that the VCC-1 provides plus two-way Fire Fighters Telephone (FFT- 7) capability. TCC-1 B: Telephone Control Center. Provides a stand-alone two-way Fire Fighters telephone (FFT-75). Includes cables, dress panel and instructions. RM-1/113M-1SA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) stand- alone cabinets. See DN-6728. AMG-E: Audio Message Generator (without microphone). Order in addition to VCC-1 or VTCC-1 if two-channel system is required. FFT-7/FFT-7S: Fire Fighters Telephone control with master handset. FTM-l: Firephone Control Module connects a remote firefighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is supervised. AA-30: Audio Amplifier, 30 watts. Switch-mode power. Includes amplifier and audio input supervision, backup input, and auto- matic switchover, power supply, cables. See AA Series data sheet, DN-3224. AA-120/AA-100: Audio Amplifier provides up to 120 watts of 25 Vrms audio power for the NFS-640. The amplifier contains an integral chassis for mounting to a CAB-134, -C4, or -D4 backbox (consumes one row). Switch-mode power. Includes audio input and amplified output supervision, backup input, and automatic switchover to backup tone. Order the AA-1 00 for 70.7 Vrms sys- tems and 100 watts of power. See AA Series data sheet, ON- 3224. VROM-(n): Factory-programmed message for installation in AMG-1. Provides up to 24 seconds of evacuation message on nonvolatile memory chip. Choose one of many standard mes- sages available. Up to two of these messages may be installed in one AMG. Includes VROM, instructions for installation and operation, and written text of message. See VROM data sheet, DN-3576. VRAM-1: Field-programmed memory to be installed in AMG-1. Provides up to 24 seconds of field-programmable evacuation message on nonvolatile memory chip. Message is programmed from microphone or cassette tape. Up to two of these nonvolatile memory chips may be installed in one AMG. Includes VRAM and instructions for installation and operation. APS-6R: Auxiliary Power Supply (expander). Provides up to 6.0 amperes of regulated power for compatible Notification appli- ance circuits. Includes battery input and transfer relay, and over- current protection. Mounts on one of four positions on a CHS-4L or CHS-4 chassis. See APS-6R data sheet, DN-5952. ACPS-2406: 6.0 amp addressable charger power supply. See ACPS-2406 data sheet, DN-6834. FCPS-24: The FCPS-24 is a remote six-amp (four-amp contin- uous) repeater/power supply. See FCPS-24 data sheet, ON- 5 132. FCPS-24S61-24S8: Remote six-amp and eight-amp power sup- plies with battery charger. See FCPS-2456/-2458 datasheet, DN-6927. UZC-256: Programmable Universal Zone Coder provides posi- tive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). See UZC-256 data sheet, DN-3404. LCD-80/LCD-80TM/FDLJ-80: 80-character, backlit LCD dis- play. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per NFS-640. See LCD-80/-80TM (DN-3 198) and FDU-80 (ON- 6820) data sheets. ACS: Annunciator Control Modules ACM-16AT, AEM-16AT, ACM-32A, and AEM-32A. See data sheets, ON-0524 and DN- 6862.. - Page 6 of 9- DN-6856:A • 12/01/06 AFM: Annunciator Fixed Modules AFM-16A, AFM-16AT, and AFM-32A. See AFM data sheet, DN-0056. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32. See LDM data sheet, DN-0551. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See ACM-SR data sheet, DN-3558. SCS: Smoke control station; eight (expandable to 16) circuits. See SCS data sheet, DN-4818. RPT-485: Repeats EIA-485 over twisted pair or converts to fiber-optic medium. See RPT data sheet, DN-4737. XP5: The XP5-M and XP5-C provide FlashScan® transponder points. See XP5 data sheet, DN-6625. XP: The XP Series Transponder provides conventional monitor and control points (CLIP mode only). See XP Series data sheet, ON-U 759. XPIQ: The XPIQ quad intelligent voice transponder for distrib- uted multichannel voice evacuation systems, an integrated audio amplification and distribution subsystem controlled by FACP. Capable of playing up to four simultaneous messages. Accepts up to four 25-watt amplifiers. See XPIQ data sheet, ON- 6823. CHS-4: Chassis for mounting up to four APS-6Rs. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers or one AMG-E and one AA-30. DP-1B: Blank Dress panel. Provides dead-front panel for unused tiers or to cover AA-30, AA-120, or one AMG-E and one AA-30. CAB-4 Series: The CAB-4 Series cabinets are fabricated from 16-gauge steel with unique full-front LEXAN®, reverse-silk- screened for durability. The cabinet assembly consists of two basic parts: a Backbox (SBB-_4), and a Locking Door (DR-_4) that may hinge right or left. Cabinets are available in four sizes, "A" through "D", with one to four tiers. A trim ring option is avail- able for semi-flush mounting. See CAB-4 Series data sheet, ON- 6857. CAB-M Series: Marine cabinets required for Lloyd's Register or U.S. Coast Guard listed use. See DN-5063. COMPATIBLE DEVICES, EIA -232 PORTS PRN-5: 80-column printer. See DN-6769. PRN-6: 80-column printer. See ON-6956. VS4095/S2: Printer, 40-column, 24 V. Mounted in external backbox. Order from Keltron, Inc. See ON-3260. CRT-2: Video display terminal. See DN-3756. COMPATIBLE DEVICES, EIA -485 PORTS ACS Series: Remote serial annunciator/control systems. See DN-0524. FDU-80: Remote LCD display, 80 characters, with LEDs. See ON-6820. LCD-80: Remote LCD display, 80 characters. See ON-3 198. LCD-80TM: Remote LCD display, 80 characters, terminal mode. See DN-3 198. LDM Series: Remote custom graphic driver modules. See ON- 055 1. ACM-8R: Remote relay module. 8 Form-C relays. See ON- 3558. RPT-485 Series: Repeater, isolator and/or fiber-optic modem. See ON-4 73 7. UDACT: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-4867. UZC-256: Zone Coder. Up to 256 programmable codes. See DN-3404. COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receiver unit of FSB- 200(5) below. See ON-6985. BEAMHRK: Heating kit for use with the reflector of FSB-200(S) below. See ON-6985. BEAMLRK: Long-range accessory kit, FSB-200(S) below. BEAMMRK: Multi-mount kit, FSB-200(S) below. BEAMSMK: Surface-mount kit, FSB-200(S) below. FSB-200: Intelligent beam smoke detector. See ON-6985. FSB-200S: Intelligent beam smoke detector with integral sensi- tivity test. See DN-6895. FSI-851: Low-profile FlashScan® ionization detector, will replace FSI-751. See ON-6934. FSI-751: Low-profile FlashScan® ionization detector. See ON- 6 714. FSP-851: Low-profile FlashScan® photoelectric detector, will replace FSP-751. See ON-6935. FSP-751: Low-profile FlashScan® photoelectric detector. See DN-6714. FSP-851T: Low-profile FlashScan® photoelectric detector with 135°F (57°C) thermal, will replace FSP-751T. See ON-6935. FSP-751T: Low-profile FlashScan® photoelectric detector with 135°F (57°C) thermal. See ON-6714. FST-851: FlashScan® thermal detector 135°F (57°C), will replace FST-751. See DN-6936. FST-751: FlashScan® thermal detector 135°F (57°C). See DN- 67 16. FST-851R: FlashScan® thermal detector 135°F (57°C) with rate-of-rise, will replace FST-751 R. See DN-6936. FST-751R: FlashScan® thermal detector 135°F (57°C) with rate-of-rise. See ON-6716. FST-851H: FlashScan® 190°F (88°C) high-temperature ther- mal detector. See DN-6936. FSD-751P: FlashScan® photo duct detector with housing. See ON-6821. FSD-751PL: Low-flow FlashScan® photo duct detector with housing, will replace FSD-751 P. See ON-6955. FSD-751 RP: FlashScan® photo duct detector with relay and housing. FSD-751 RPL: Low-flow FlashScan® photo duct detector with relay and housing, will replace FSD-751 AR See DN-6955. FAPT-851: FlashScan® Acclimate PIusTM low-profile multi-sen- sor detector, will replace FAPT-751. See DN-6937. FAPT-751: Acclimate PIusTM low-profile multisensor detector. See ON-6833. FSH-751: FlashScan® HARSHTM Hostile Area Smoke Head. See DN-6875. FSL-751: FlashScan® VIEW® laser photo detector, will replace LPX-751. See ON-6886. LPX-751: Low-profile VIEW® laser photo detector. See DN- 5306. B224RB: Low-profile relay base. B224B1: Isolator base for low-profile detectors. B71OLP: Low-profile base. Standard U.S. style. B501: European-style, 4' (10.16 cm) base. B501BH: Sounder base, includes B501 base above. Constant tone. B501 BHT: Sounder base, includes B501 base above. Temporal three tone. FMM-1: FlashScan® monitor module. See DN-6 720. FDM-1: FlashScan® dual monitor module. See DN-6 720. DN-6856:A • 12/01/06 - Page 7019 FZM-1: FlashScan® two-wire detector monitor module. See DN-6 720. FMM-101: FlashScan® miniature monitor module. See DN- 6720. FCM-1: FlashScan® NAC control module. See DN-6724. FRM-1: FlashScan® relay module. See DN-6 724. FSM-101: FlashScan® pull station monitor module. NBG-12LX: Manual fire alarm station, addressable. See ON- 6726. ISO-X: Isolator module. See DN-2243. XP Series: Transponder. See DN-0 759. XP5-M: FlashScan® transponder, five monitor points. See ON- 6625. XP5-C: FlashScan® transponder, five control points or Form-C relays. See DN-6625. XP6-C: FlashScan® six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan® six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan® six-relay (Form-C) control module. See DN-6926. XP10-M: FlashScan® ten-input monitor module. See DN-6923. XPIQ: Intelligent quad transponder. See DN-6823. OTHER OPTIONS DPI-232: Direct Panel Interface, specialized modem for extend- ing serial data links to remotely located FACPs and/or peripher- als. See DN-6870. LEM-320: Loop Expander Module. Expands each 640 to two Signaling Line Circuits. See ON-6881. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (single-address-style) or in CHS-M2 position. See ON- 6860. NCM-W: Network Communications Module, Wire. Order one NCM per network node (CPU-640 or NCA). See DN-6861. NCM-F: Network Communications Module, Fiber. Order one NCM per network node (CPU-640 or NCA). See DN-6861. NCS5-W-ONYX: Network Control Station, Wire. UL-Listed graphics PC with mouse, 17' color flat-screen LCD monitor. Order as necessary for network systems. Each NCS consumes one of 103 network addresses. See DN-6868 (previous NCS- W), ONYX® DN-6869. NCS5-F-ONYX: Network Control Station, Fiber. UL-Listed graphics PC with mouse, 17" color flat-screen LCD monitor. Order as necessary for network systems. Each NCS consumes one of 103 network addresses. See DN-6868 (previous NCS-F), ONYX® DN-6869. VeriFire-TCD: VeriFire® Tools CD-ROM. Contains program- ming software for the NFS-640, NCA, and XPIQ. Includes local panel connection cable. Programming PC requires a serial port connection. See DN-6871, ACM-24AT: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active! Alarm LEDs can be programmed (by powered-up switch selec- tion) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See ON-6862. BAT Series: Batteries. NFS-640 utilizes two 12 volt, 12 to 55 AH batteries. See DN-6933. PS Series: Batteries. NFS-640 utilizes two 12 volt, 12 to 55 AH batteries. See DN-1109. NFS-LBB: Battery Box (required for batteries over 25 AH). BR: Same as above but red. - Page 8 of 9— DN-6856:A • 12/01/06 SYSTEMISPECIFICATIONS I ---•. 1 System Capacity Intelligent Signaling Line Circuits ............1 expandable to 2 Intelligent detectors .........................................159 per loop Addressable monitor/control modules ..............159 per loop Programmable internal hardware and output circuits (4 standard) ......................................................................68 Programmable software zones.........................................99 Special programming zones.............................................14 LCD annunciators per CPU-640/-640E and NCA (observe power)................................................................32 ACS annunciators per CPU-640/-640E ........................32 address x 64 points ACS annunciators per NCA ...............32 address x 64 or 96 points NOTE: The NCA supports up to 96 annunciator address points per ACM-24/48. Specifications Primary input power, CPU-640 board: 120 VAC, 50/60 Hz, 3.0 amps. CPU-640E board: 220/240 VAC, 50/60 Hz, 1.5 Amps. Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 Amps of available power. This is shared by all internal modules. Standard notification circuits (4): 2.5 A each. Four-wire detector power: 1.25 A. Non-resettable regulated power outputs: 1.25 A each. Battery charger range: 12 AH —55 AH. Use separate cabi- net for batteries over 25 AH. Optional high-capacity (25 - 120 AH) battery charger: CHG-120 (see CHG-120 data sheet, DN-6040). Float rate: 27.6 V. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0- 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (nortcondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic NFS-640 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL: S635 ULC:CS118 FM APPROVED Exceptions - CPU-640E, PRN-5, Propri- etary service CSFM: 7165-0028:214, 7170-0028:216 MEA:317-01-E City of Chicago City of Denver Lloyd's Register: 02/60007 U.S. Coast Guard: 161.002/42/1 China Classification Society (CCS): #NL05T00001 (NFS-640E) CCCF: Certif. #2003081801600815 Standards The NFS-640 complies with the following UL Standards and NFPA 72 Fire Alarm Systems requirements: - UL 864 (Fire) - UL 1076 (Burglary) - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (requires 4XTMF). - PROPRIETARY (Automatic, Manual and Waterflow). Not applicable for FM. - EMERGENCY VOICE/ALARM. Acclimate PlusTM, HARSH TM NISTM, Notifier Integrated SystemsTM, and NO-Tl.FIflENETTM are all trademarks; and FlashScan®, NION®, NOTIFIER®, ONYX®, UniNet®, VeriFire®, and VIEW® are all registered trademarks of Honeywell International Inc. ©2006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended lobe used for installation purposes. _______ We try to keep our product information up-to-date and accurate. 16101111 We cannot cover all specific applications or anticipate all requirements. ENGINHIIII 18 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 9 of 9— DN-6856:A • 12/01/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:214 Page 1 of 2 CATEGORY: Control Unit (Non High-Rise) LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Model NFS-640, NFS-640E fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), automatic, manual, waterfiow and sprinkler supervisory services. Refer to listee's data sheet for detailed product description and operational considerations. System components: CPU-640, 640E CPU Board NCA Network Communication Annunicator NCM-W/F Network Control Module LEM-320 Loop Expander Module KDM-2 Keyboard Display Module TM-4 Transmitter Module CAB-4 Series Enclosure TR-A4, -B4, -C4, -D4 Trim Ring DP-DISP Display Dress Panel DP-1 B Blank Panel BMP-1 Blank Module XPDP, DPDW-IB, DPSW-1B, VP-213 Dress Panels CHS-4MB, -M2,-4L,-4N Chassis NFS-LBB, BB-25, BB-17 Battery Box BP-4 Battery Panel STS-1 Security Tamper Swith UDACT Universal DACT UZC-256 Universal Zone Coder RPT-W, RPT-485W, RPT-485WF Repeater Wire RPT-F Repeater Fiber SCS-8 Smoke Control Station SCE-8 Smoke Control Expander SCS-8L Smoke Control Lamp Driver Station SCE-8L Smoke Control Expander Lamp ARM-4 Auxiliary Relay Module APS-6RIAPS-6RE Auxiliary Power supply ACPS-2406 Addressable Power Supply CHG-120 Battery Charger FCPS-24 Field Charger Power Supply DCM-4RK Dual Channel Module CRM-4RK Control Relay Module CRE-4 Control Relay Expander ICM-4RK Indicating Control Expander ICE-4 Indicating Circuit Expander *lSOX Isolator Module XP5-M, XP5-C Transponder XPIQ Transponder Quad Intelligent Audio XPC-8 Transponder Control Module XPM-8, XPM-8L Transponder Monitor Modules XPP-1 Transponder Processor XPR-8 Transponder Relay Module *Corrected 11-15-2002 Listing No. 7165-0028:214 Page 2 of 2 PRN-5 Printer VS4095 Keltron Remote Printer CRT-2 Display Terminal NBG-12LX Addressable Manual Pull Station NBG-12LRA Agent Release Abort Station FZM-1 Interface Module REL-2.2K Releasing Supervision Kit INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL-864, 8th Edition Standard. NOTE: For Fire Alarm Verification feature (delay of fire alarm signal), the maximum - Retard/Reset/Restart period shall not exceed 30 seconds. Corrected 11-15-2002 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager July 20, 2004 DN-6820- D-123 (0 NOTF I ER® GENERAL The FDU-80 is a compact, cost-effective, 80 character, backlit LCD Fire Annunciator for use with the NOTIFIER AFP-300, AFP- 400, AFC-600, and NFS-640 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and dis- plays complete system point status information. Up to 32 FDU- 805 may be connected onto the EIA-485 Terminal Mode port of each control panel, The FDU-80 requires no programming, which saves time during system commissioning. NOTES: The FDU-80 is compatible with the NOTIFIER AFP-300/ 400 Rev. 3.62 or higher, AFC-600 (all revisions), and NFS- 640 Rev. 2.01 or higher. The FDU-80 can be used on the same data loop as the LCD-80/LCD-80TM annunciators revision 1.6 software or higher. FEATURES 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervi- sory, and Alarm Silenced. No programming necessary - FDU-80 connects to the terminal mode port. Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels. Time and date display field. Aesthetically pleasing design. May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. - Can be remotely located up to 6,000 feet (1828.8 m) from host control panel. Local piezo sounder with alarm and trouble resound. Semi-flush-mounts to 2.188/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10103) or three- gangable electrical switchbox. - Surface-mounts to NOTIFIER SBB-3 surface backhox. OPERATION The FDU-80 annunciator provides the FACP with point an- nunciation with full display text on an 80-character LCD dis- play. The FDU-80 also provides an array of LEDs to indicate system status, and also includes control switches for remote control of critical system functions. FDU-80 80-Character Liquid Crystal Display Fire Annunciator Section: Annunciators California State Fire Marshal '4!) 7120-0028:209 LISTED CS100 S635 MEA 245-00-E FDU-80 Annunciator The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communica- tions (two in and two return); and two for the 24 VDC regu- lated power. Dip switches control local functions such as: piezo disable, control switches/key switch disable, transmit/ receive mode. INSTALLATION The FDU-80 can be semi-flush mounted to a 2.188/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10103) or three-gangable electrical switchboxes. Alter- nately, an SBB-3 surface hackbox is available for surface. mount applications. NOTIFIER® is a Honeywell company. This document is not intended to he used for installation purposes. We try io keep our ISO 9001 product information up-to-date and accurate. cover cannot coer all specific applications or anticipate all requirements. All specifications are subject to change without notice, i •] For more information, contact NOTIFIER. Phone. 12031 484-7161 FAX: (203) 484-7118 ENGINEERING A MANUFACTURING NOTI F I ER 7 12 Clintonville Road. Northford, Connecticut 06472 Q UALIT Y SYSTEMS Made in the U.S A - ON-6820 07/20/04 - Page 1 012 ORDERING INFORMATION FDU-80 80 character, backlit, LCD Fire Annunciator with control switches for remote control of system functions, and key-switch lock. 10103 Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush-mount applications. SB B-3 Three-gang surface backbox for surface-mount applications. FDU-80 TERMINAL MODE WIRING EXAMPLE Up to 6,000 ft. (1828.8 m) between EACH DEVICE in the ElA-485 loop — Terminal Mode / FDU-80 FDU-8 ElA-485 ... (2-wires) 24VDC (2-wires) Up to 6,000 ft. (1828.8 in) Terminal Mode / back from last device - FDU-80 EtA-485 return j to end of EIA485 loop r..... (2-wires) 45 AFP-400 Notes: EtA-485: Maximum of 6,000 feet (1828.8 m) cable length from FACP to FDU-80 annunciators and back to FACP (6,000 feet [1828.8 ml total). Circuit is power-limited. Up to 32 FDU-80 annunciators may be used on the ElA-485 circuit. When multiple FDU-80s are used, certain panels will require additional power supplies (refer to panel documentation). Between each FDU-80 annunciator are four wires: a twisted-shielded pair for data communications and a pair for 24 VDC power. The return circuit only requires two wires for data communication supervision, wired from the last FDU-80 annunciator on the loop. On the AFP-300/400, software revision 3.62 or higher is required. MOUNTING TO ACKOX(ES) The FDU-80 annunciators can be semi-flush-mounted in a three-gang electrical box with a minimum depth of 2.188" (5.556 cm) (NOTIFIER P/N 10103). The FDU-80 annunciators can be mounted in three gangabte electrical switch boxes connected together. NOTE: Alternately, FDU-80 annunciators can be mounted to the SBB-3 surface backhox for surface-mount applications. FDU-80 flange Mounting Holes (4) ........ " FIRE ALARM ANNUNCIATOR n E3 11 5ST61S PILL iOFiiL 11'C"S fl NON 3.-20.-C'C LL lr 5.813" (14.764 cm) wide x4" (10.16 cm) high x minimum 2.188" (5.556 cm) deep, three-gang electrical box (NOTIFIER P/N 10103, shown at right). Page 2 of 2 - DN-6820 07/20/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:209 Page 1 of 1 CATEGORY: Annunciators LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FDU-80 and *FDu..80G remote fire annunciators. Units are compact 80-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. 'Re 10-03-06 jw ir This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager June 13, 2005 DN-6726 • H-240 NOTIFIER® by Honeywell GENERAL The NOTIFIER NBG-12LX is a state-of-the-art, dual-ac- tion (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any NOTIFIER intelligent control panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. FEATURES Maintenance personnel can open station without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTI- VATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.1 mm2 wire). Semi-flush, mounts to a standard single-gang (2.125" [5.3975 cm] minimum depth), double-gang, or 4 (10.16 cm) square electrical box. Smooth dual-action design. Within ADA 5 lb. pull force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-1 2LX stations per loop on classic protocol systems. Up to 159 NBG-12LX stations per loop on FlashScan® protocol systems. Dual-color LED blinks green to indicate normal on FlashScan® systems. CONSTRUCTION Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from FlashScan® and NOTIFIER® are registered trademarks of Hon- eywell International INC. LEXAN® is a registered trademark of ( PIf ,k&,r,, ,,f I.-ti,- NBG-12LX Addressable Manual Pull Station with FlashScan® Section: Intelligent/Addressable Devices Patented, U.S. Patent No. 0428,351; 6,380,846 U.S. Patent Pending: 091686,286 C®US California State Fire 1'Yj!° LISTED S692 U.S. Coast Guard liVl 161.002/23/3 (AFP-200) APPROVED B SMI 93/60141 (E3) 02/6007 C 13 13066760047 f The NBG-12LX Addressable Manual Pull Station the bottom of the station. To reset the station, simply un- lock the station with the key and pull the door open. This action resets the handle; closing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address set- tings (1 - 159 on FlashScan® systems, 1 - 99 on CLIP product information up-to-date and accurate. We cannot cover all specific applications or ISO 9001 This document is not intended to be used for installation purposes. We try to keep our I anticipate all requirements. All specifications are subject to change without notice. i For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 • .. ______ NOT I Fl FEW I INGINIERING & MRNIIFACTURINC by Honeywell 12 Clintonville Road, Northtord, Connecticut 06472 QUALITY SYSTEMS -. DN-6726 • 06/13/05 - Page 1 012 PRODUCT LINE INFORMATION NBG-12LX Dual-action addressable pull station. Includes key locking feature. SB-10 Surface backbox. SB-I/O Indoor/outdoor surface backbox. BG-TR Optional trim ring. INSTALLATION The NBG-12LX will mount semi-flush into a single-gang, double-gang, or standard 4 (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O surface backbox. If the NBG-12LX is being semi- flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mount- ing with 4' (10.16 cm) or double-gang boxes (not with single-gang boxes). _ - H I I JL i Terminal Connections 1 SLC H . 701116, Li :T; Back of station without door. ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 375 pA. ARCHITECTURAL! ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-coded, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycar- bonate equivalent) with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10; or semi-flush mount- ing on a standard single-gang, double-gang, or 4' (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Detailol BREAKAWAY TAB 14 * 15 0 ADDS 0 2 032 0 3 10 87 9 87 LED MARY DECIMAL SWITCHES *Remove tab to select addresses above 99 (FlashScan® systems only). Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2 012 - DN-6726 • 06/13/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484*7161 FAX (203) 484-7309 DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-I2LAOB, NBG- 12-LO, NBG-I2LOB, NBG-12W, NBG-I2LW, NBG-12NC, NBG-I2WP, NBG-12LWP, NBG- 12L, NBG-I2LX, NBG-I2LA, NBG-I2PS, NBG-12LSP, NBG-I2LPS, NBG-12LPSP, NBG- I2SP, NOT-BG12LX, and *NBG..12L)(SP fire alarm pull boxes. All units except Model NBG- 12S are dual action pull stations. Models NBG-I2LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-I2WP, NBG-I2LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12LO, NBG- 12LAOB and NBG-1 2LOB are intended for outdoor use when installed with Models WBB, SB- I/O, or WP-1 0 back box. Refer to listee's Installation Instruction Manual for details. *Rev. 1-06-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. - Date Issued JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager DN-6935:A • H-202 FSP.851 and FSP-851 T Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan® General Notifier 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conven- tional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously moni- tored and reported to the panel. Point ID capability allows each detectors address to be set with decade address switches, providing exact detector location for selective main- tenance when chamber contamination reaches an unaccept- able level. The FSP-851 photoelectric detector's unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sens- ing on the FSP-8511. FSP-851 and FSP-851T detectors are compatible with all Notifier intelligent Fire Alarm Control Pan- els (FACP). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier engineering that greatly enhances the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fash- ion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. FlashScan (NFS-640, NFS-3030) and classic CLIP sys- tems (AFP-100, AFP-200, AFP-300, AFP-400, NFS-640, AM2020/AFP1010, NFS-3030) compatible. Rotary, decimal addressing (1-99 on current classic sys- tems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory (RA400Z). Dual LED design provides 3600 viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm. Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white Bayblend®, designed to commer- cial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Backward compatible. :. FSP-851 with B7IOLP base FSP-851T with B7IOLP base Specification Size: 2.1" (5.3cm) high x 4.1" (10.4cm) diameter installed in B501 base, 6.1" (15.5cm) diameter installed in B71OLP base. Shipping Weight: 5.20z. (147g). Operating Temperature: FSP-851, 0°C to 49°C (32°F to 120°F); FSP-851T, 0°C to 38°C (32°F to 100°F). Low temper- ature signal for FSP-851T at 45°F +1- 10°F (7.22°C +1- 5.54°C). UL Listed Velocity Range: 0-4000 ft/mm. (1219.2 rn/mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (570C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com FSP-851 and FSP-851T are listed for use in ducts, but they are NOT listed for use inside duct smoke detector housings. See Duct Application Smoke Detectors Guide, document A05- 1004, available at systemsensor.com, for details on pendant- mount applications. DN-6935:A • 12/28106 - Page 1 of 3 Address Dial on back of Detector REMOTE ANNUNCIATOR CONTROL 3 PANEL ---------------------------- : Wiring Diagram ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 250pA @ 24VDC (with no communication enabled); 3601JA @ 24VDC (one communica- tion every five minutes with LED enabled). LED Current (max.): 6.5mA © 24VDC ('ON'). BASES AVAILABLE B71OLP: 6.1" (15.5cm) diameter. B501: 4.1" (10.4cm) diameter. B501BH or B501BHT: Sounder base assembly. Includes B501 base. B224RB Relay Base: Screw Terminals, up to 14AWG (2.0mm); Relay Type, Form-C; Rating, 2.OA © 30VDC resis- tive, 0.3A © 110VDC inductive, 1.0A © 30VDC inductive; Dimensions, 6.2" (15.748cm) x 1.2" (3.048cm) x 1.2" (3.048cm). B224B1 Isolator Base: Dimensions, 6.2" (15.748cm) x 1.2" (3.048cm) x 1.2" (3.048cm); Maximum, 25 devices between isolator bases. Installation FSP-851 plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors with- out using a ladder. Mount base on an electrical backbox which is at least 1.5" (3.81 cm) deep. Suitable mounting base boxes include: 4.0" (10.16cm) square box. 3.5" (8.89cm) or 4.0" (10.16cm) octagonal box. Single-gang box (except relay or isolator base). With B501BH or B501BHT base, use a 4.0" (10.16cm) square box. With B224RB or 13224B1 base, use a 3.5" (8.89cm) octago- nal box, or a 4.0" (10.16cm) octagonal or square box. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: 51115 ULC Listed: CS915 (FSP-962A, FSP-8511A) MEA Listed: 225-02-E FM Approved CSFM: 7272-0028:206 Maryland State Fire Marshal: Permit #2122 BSMI: C1313066760036 CCCF: Certif. #2004081801000017 (FSP-851T) Certif. #2004081801000016 (FSP-851) Lloyd's Register: 03/60011 Page 2 of 3- DN-6935:A • 12/28/06 Product Line Information NOTE: 'A" suffix indicates ULC listed model. FSP-851 :Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FS P-851 A: Same as FS P-851 but with ULC listing. FSP-851T:Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA:Same as FSP-8511 but with ULC listing. BASES B71 OLPBP: Standard U.S. low-profile base, pkg. of 10. B71OLPA:Standard U.S. low-profile base, ULC listing. B501BP:Standard European flangeless base, pkg. of 10. B501A:Standard European flangeless base, ULC listing. B501B11(A):Sounder base, includes B501 (A) base. B501 BHT(A):Same as B501 BH(A), but includes temporal sounder. 8224RB(A):lntelligent relay base. B224B1(A):lntelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES F1 10: Retrofit replacement flange for older style bases. Con- verts old high profile base for use with FlashScan detectors. RA400Z(A):Remote LED annunciator. 3-32VDC. Fits U.S. single-gang electrical box. Supported byB710LP(A) and B501 (A) bases only. SMK400:Surface mounting kit provides for entry of surface wiring conduit. For use with B501 (A) base only. RM K400: Recessed mounting kit. For use with B501(A) base only. SMB600:Surface mounting kit for use with B71OLP(A). BCK-200B:Black detector covers, box of 10. For use with FSP-851 only. M02-04-01 :Test magnet. M02-09-00:Test magnet with telescope stick. XR2B:Detector removal tool. Allows installation and/or removal of FlashScan Series detector heads from base in high ceiling installations. T55-127-000: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-ft. sections. DETECTOR GUARDS NOTE: Some guards listed below may not be applicable to FPS models. SDG-773:Smoke detector guard; cover is 7.0" (17.78cm) square x 3.0" (7.62cm) deep. This guard is mechanically com- patible with FSP-751. It is UL-compatibility listed with the FSP-851 (file UL S5515). STI 9601 :Low-profile , flush-mount smoke detector guard, wire.* STI 9602:Low-profile, surface-mount, smoke detector guard, wire.* STI 9609:High-profile, flush-mount, smoke detector guard, wire.* STI 9605:High Profile, surface-mount, smoke detector guard, wire.* STI 9604: Flush-mount, heat detector guard, wire.* STI 9610:Surface-mount, heat detector guard, wire. STI-8200-SS:Flush-mount stainless steel smoke detector guard (compatibility pending). STI-8230-SS:Surface mount stainless steel smoke detector guard (compatibility pending). * For dimensions and additional information on STI Steel Web Stoppers, see data sheet DN-4936. Notifier® and FlashScan® are registered trademarks of Honeywell Interna-tional Inc. Bayblend® is a registered trademark of Bayer Corporation. ©2007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I s0 9001 _____________ We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUIA1DRING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 3 of 3— DN-6935:A • 12128106 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:206 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FSP-751, HPX-751, FSP-751T, *FSHJ51*(l)FApTj51 *FApT851 *F5P851 and *FSP..851T photoelectric type smoke detectors. Models FSP-751T and *FSP..851T employ a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. *Models FSP-751, FSP-751T, *FApT..751 *FApT..851 *FSP. 851 and *Fsp..851T Models FSP-751 and FSP-751T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. *Model FSH-751 is suitable for open areas with air velocity between 0-400 fpm. NOTE: 1. (')Combined with 7272-0028:208 2. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 07-24-2002 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Dale Issued: JUNE 4,, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager (0 NOTIFIER® GENERAL Four different monitor modules are available for NOTIFIER in- telligent controls to suit a variety of applications. Monitor mod- ules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1). FMM-1 - is a standard-sized module (typically mounts to a 4 [10.16 cm] square box) that supervises either a Class A (Style D) or Class 8 (Style B) circuit of dry-contact input de- vices. FMM-101 - is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the FMM-101 to often be mounted in a single-gang box behind the device it's monitoring. FZM-1 - is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. FDM-1 - is a standard-sized dual monitor module used to monitor and supervise two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FlashScan® is a registered trademark of NOTIFIER. FMM-1 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan® sys- tems, 01 - 99 on CLIP systems. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1 Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 can be used to replace MMX-1 mod- ules in existing systems. August 23, 2004 DN-6720• H-220 FMM-1, FMM-101, FZM-1, FDM-1 Monitor Modules with FlashScan® Section: Intelligent/Addressable Devices < FM 9> LISTED C5669 APPROVED S635 U.S. Coast Guard 161.002/23/3 (AFP-200: FMM-1/-101, FZM-1) 161.002/42/1 California State Fire (NFS-640: FMM-1I-101) Marshal 7300-0028:202 19° 0 detail of FDM-1 510 4[//4V\11 3111 111112 1 - note "ones" 7 2',,/l3 101514 2 addresses are 6 TENS 6n- 3 0, 2, 4, 6, 8 only 4(1 5 2'" 4 ONES 0 I ILOOP ADDRESS FMM-1 Applications - Use to monitor a zone of four- wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for su- pervision of the Style D circuit. Maximum IDC loop length is 2,500 ft./762 m (20 ohms maximum). 93/60141 (E3) (FMM-1I-101, FZM-1) 94/60004/E2 (AFP200: except FDM-1) 02/60007 (NFS-640: FDM-1) MEA 143-01-E (FDM-1) 317-01-E (FMM- 11-101) 345-02-E (FMM- 11-101) 457-99-E (FZM-1, FMM-1I-101) 447-99-E FMM-1 and FZM-1 NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our IS09001 product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203)484-7118 ENGINEERING &MNOFACTIJRING NOTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6720 . 08/23/04 - Page 1 016 FMM-1 Operation - Each FMM-1 uses one of 159 avail- able module addresses on an SLC loop, It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FMM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 pA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125' (5.398 cm) deep box. FMM-101 MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the panel. Powered directly by two-wire FACP. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan® sys- tems, 01 - 99 on CLIP systems. 150 ADDRESS r_6L TENS ONES 1 7_71 LI Li LI LI The FMM-101 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101 is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101 can be used to replace MMX-101 module in existing systems. FMM-1 01 Applications- Use to monitor a single de- vice or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry- contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47 ohm End-of- Line Resistor (provided) terminates the circuit. FMM-1 01 Operation— Each FMM-101 uses one of 159 available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). FMM-101 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.5° (1.270 cm) deep. Wire length: 6' (15.24 cm) minimum. FZM-1 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 —159 on FlashScan®sys- tems, 01 - 99 on CLIP systems. LED flashes during normal operation (this is a program- mable option). LED latches steady to indicate alarm on command from control panel. The FZM-1 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional de- tectors back to the control panel. All two-wire detectors be- ing monitored must be UL compatible with the module. The FZM-1 has a panel-controlled LED indicator and can be used to replace MMX-2 modules in existing systems. FZM-1 Applications - Use the FZM-1 to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Ini- tiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (pro- vided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1 Operation - Each FZM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FZM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 255 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VRMS maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 45" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 of 6 .- DN-6720 - 08/23/04 FDM-1 DUAL MONITOR MODULE The FDM-1 Dual Monitor Module is intended for use in in- telligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecu- tive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally closed security devices. The module has a single panel-controlled LED. NOTE: The FDM-1 provides two Class B (Style Y) bC circuits ONLY. Class A (Style Z) IDC circuits are NOT supported in any application. FDM-1 Specifications Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 5.7 mA (LED on). Maximum operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wiring resistance: 1,500 ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5' (11.43 cm) high x 4' (10.16 cm) wide x 2.125" (5.398 cm) deep. FDM-1 Automatic Addressing —The FDM-1 auto- matically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1 is set to address "56", then it will automatically assign itself to ad- dresses "56" and "57". NOTE: "ones" addresses on the FDM-1 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first ad- dress, and terminals 8 and 9 use the second address. 4CAuTIoN! V Avoid duplicating addresses on the system. INSTALLATION FMM-1, FDM-1, and FZM-1 modules mount directly to a stan- dard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are pro- vided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. PRODUCT LINE INFORMATION FMM-1 Monitor module. FMM-101 Monitor module, miniature. FZM-1 Monitor module, two-wire detectors FDM-1 Monitor module, dual, two independent Class B circuits. SMB500 Optional surface-mount backbox. ARCHITECTS'/ENGINEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are avail- able from NOTIFIER. rall MOUNTING DIAGRAMS For slandard-sized ) modules 0 DN-6720 08/23/04 - Page 3 of 6 WIRING DIAGRAMS The following wiring diagrams are included: FDM-1, typical dual two-wire Style B initiating device circuit configuration. FMM-101, typical two-wire Style B initiating device circuit configuration. FMM-1, typical two-wire initiating circuit configuration, NFPA Style B. FMM-1, typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. FMM-1, typical two-wire initiating circuit configuration for security Systems (with alarm versus short capability). FZM-1, interface two-wire conventional detectors, NFPA Style B. FZM-1, interface two-wire conventional detectors, NFPA Style D. FRM-1, relay control module used to disconnect a power supply. WIRING D P'Ic :7!' Fig. I FDM-1: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits (L&H) TO Ne each power-limited to Device —) FROM Panel 230 pA max. 12 VDC max. MONITOR W or Previous Device 47K EOL MODULE rHHH1 I LJ 1 0 Resistor Communication Line ELR-47K 32 VDC maximum. Twisted-pair is + recommended. 47K EOL Resistor ii 3 ' All wiring shown is supervised ELR-47K 92E L_ NE DDRESS and power limited. JJ I.Li V Connect modules to listed compatible , NOTIFIER control panels only. ANY NUMBER of UL Listed contact closure devices may be used. 6822w1r1.wmf DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. Install contact closure devices per manufacturer's installation instructions. (+) 41 TO y NEXT H DEVICE UL LISTED BLACK RED Compatible (-) H FMM-101 Panel Control 6789 6789 510 5 4l1 4 3 12 3 . - 2"- 13 2 10 1514 1 (+) (-) VIOLETJ I YELLOW Tj!4IRINGIDIAGRAM: FMM-1[ - 47K EOL INCLUDED Fig. 2 FMM-101: Typical two-wire Style B initiating device circuit configuration. - 6720w1 wf _______________________ Page 4 of 6 - DN-6720 . 08/23/04 Connect modules to listed compatible control panels only. Terminal wiring must be power limited. WIRING LU 1j 1 DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. ' , _i1 DO NOT LOOP wire under terminals. Break wire run to provide supervision of connections. THIS PAGE: Detectors must be UL listed compatible with module. Install detectors per manufacturers' installation instructions. Power to the interface module must be externally switched to reset the detectors. An FRM-1 relay control module can be used to switch power from a standard power supply: see Fig. 7 below. V Fig. 6 FZM-1.: Interface two-wire conventional detectors, NFPA Style B. TO Next (+) H FROM Panel Device or Previous INTERFAcE Device MODULE 0 Communication Line 32 VDC maximum. 4 9 00 0 Twisted-pair is recommended. 3.9K EOL Listed Battery Backup Resistor 60 3 I switched DC (included) ONES I power supply. A2143-10 LOO P ADDRESS ° 0 9 Optional Branch Circuit TO Next Interface Module 6720w1r5wn,f Module supervises supply voltage and detector loop. V Fig. 7 FZM-1: Interface two-wire conventional detectors, NFPA Style D. TO Next FROM Panel Device (i) or Previous Device INTERFACE Ici , Communication Line 32 VDC maximum. Twisted-pair is lo g recommended. 3.9K EOL Resistor chided) required ENS terminals 2 21 6) 3 at 8 & 9 06 Listed Bae Backup A2143-10 + switched DC Rrs OOCSADD power supply. L°o Optional Branch Circuit 11 TO Next Interface Module M odule supervises supply voltage and detector loop. V Fig. 8 FRM-1: Relay control module used to disconnect a power supply. TO Next (—) FROM Panel Device or Previous Device DC POWER SUPPLY () Listed for Fire (—) Protection with [Battery Backup (—) . CONTROL ' IMsJi1uJI PP ETUI I Communication Line 32 VDC maximum. Twisted-pair is recommended. Page 6 of 6 - DN-6720 • 08/23/04 WIRING D r..c1 :7VM- THIS, Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Install contact closure devices per manufacturers' installation instructions. Any number of UL-listed contact closure devices may be used. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. 'V Fig. 3 FMM-1: Typical two-wire initiating device circuit configuration, NFPA Style B. 47K EOL Resistor ELR-4711 TO Next Device MONITOR Initiating Device Circuit (IDC) {MODULE (b t1_ NFPA Style B, power limited: 1 VDC max. 02J —) FROM Panel or Previous —4 Device J Communication Line 32 VDC maximum. — Twisted-pair is recommended. 1 Communication Loss ONEs 'DRESS (optional connection for panels which support this feature) 00 FUTURE FEATURE V Fig. 4 FM114-1: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. EOL Resistor is internal at terminals 8 & 9 TO Next Device MONITOR ci? _MODULE 1157TENs 20 IIj 5 Communication Loss LLOOP ADD8!!I (optional connection for panels which support this feature) FUTURE FEATURE FROM Panel or Previous Device Communication Line 32 VDC maximum. Twisted-pair is recommended. yr Fig 5 FMM-1: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). Initiating Device Circuit (IDC) NFPA Style B, power limited: 230 pA max. @ 12 VDC max. 14K Series Resistor 47K EOL Resistor ELR-47K TO Next 4L.\ Device nTENS2 09 0 98 1 —) A FROM Panel or Previous —4 Device J\ Communication Line 32 VDC maximum. — Twisted-pair is recommended. M6 ( 75 Communication Loss which support this feature) LOOP ONES ADDRESS (optional connection for panels FUTURE FEATURE — __ Co r4.wf DN-6720 . 08/23/04 - Page 5 of 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, *FTM.1 monitor modules and Models FCM-1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. *Model FTM-1 is intended to be used with Notifier Models NFS-640 (CSFM Listing Nos. 7165-0028:214 and 7170-0028:216), NFS-3030, NFS2-3030 (CSFM Listing Nos. 7165-0028:224 and 7170-0028:223) Fire Alarm Control Units. *Rev. 07-12-2006 vo This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ;... recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager April 5, 2004 DN-6724 H-230 ® FCM and FRM Series NOTIFIER Control and Relay Modules with FlashScan® Section: Intelligent/Addressable Devices GENERAL FCM-1 Control Module - The FCM-1 Addressable Control Module provides NOTIFIER intelligent control pan- els a circuit for Notification Appliances (horns, strobes, speak- ers, etc.) or to monitor a telephone circuit. Addressability al- lows the FCM to be activated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM.1 Relay Module - The FRM-1 Addressable Re- lay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, damp- ers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FEATURES Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM module requires power (for horns, strobes, etc.), audio (for speakers), or a telephone riser (for hand- sets). Internal relay feature available on FlashScart® sys- tems only. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM may be used to switch 24-volt NAC power, au- dio (up to 70.7 VRMS) or telephone. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan®, 01 - 99 on traditional systems. Speaker, audible/visual, and telephone applications may be wired for Class B or A (Style Y or Z). APPLICATIONS The FCM is used to switch 24 VDC audible/visual power, high-level audio (speakers), or control telephone devices. The FlashScan® is a registered trademark of NOTIFIER. Noryl® is a registered trademark of GE Plastics, a subsidiary of General Elec- tric Company. California State Fire Marshal LISTED CS669 S3705 MARYLAND M EA State :i: # Iloo a;shal <@> 457-99-E APPROVED (See wiring diagram Fig. 5 for FRM-1) FIRM may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four- wire smoke detector power. CONSTRUCTION The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-159). The FCM is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FIRM provides two Form-C dry contacts that switch together. OPERATION Each FCM or FIRM uses one of 159 possible module ad- dresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. 933MME= For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203)484-7118 ENGINEIRING & MANUFACTURING NOTI Fl ER" 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6724 04/05/04 - Page 1 of 4 Page 2 of 4 - DN-6724 04/05/04 (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM will discon- nect the supervision and connect the external power supply in the proper polarity across the load device. The disconnec- tion of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the communica- tion loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a module and a sensor address. SPECIFICATIONS For FCM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll (CLIP mode), 375 pA group poll (FlashScan® mode) with LED flashing. External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). Drain or, external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. SPECIFICATIONS For FRM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (FlashScan® mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120° F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4(101.6 mm) square x 2.125" (53.975 mm) deep box. RELAY CONTACT RATINGS For both FCM and FRM models Load Description Application Maximum Volge Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R = 5 ms) Coded 30 VDC 0.5 A Inductive (LIR = 2 ms) Coded 30 VDC 1.0 A Inductive (PF = 0.35) Non-Coded 125 VAC 0.5 A PRODUCT LINE INFORMATION FCM-1 Intelligent Addressable Control Module. FRM-1 Intelligent Addressable Relay Module. A2143-20 Capacitor, required for Class A (Style Z) opera- tion of speakers. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier - required by UL for separating power-limited and non-power limited wiring in the same junction box as FCM-1. I MOUNTING DIAGRAMS Note CB500 Module Barrier, which creates isolated quadrant. ISOLATED QUADRANT TO Next Device ___________ LCONTROL [C? MODULE 107 ENS 21- lb (+)(+) TO NEXT control module or EOL Relay. ONE RELAY REQUIRED for each circuit. Some control panels have the RELAY BUILT IN and do not require external wiring. Refer to the NOTIFIER manual. EOL Resistor is internal at terminals 8 & 9 r— - UL listed EOL Relay shown 7 energized 24 VDC coil A77-716B The Face Plate V WIRING DIAGRAMS The following wiring diagrams are provided: FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. FCM-1: Typical fault-tolerant notification appliance circuit con- figuration, NFPA Style Z. FCM-1: Typical wiring for speaker supervision and switching, NFPA Style Y. FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. FRM-1: Relay module wiring diagram. V Fig. I FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Communication Line 32 VDC max. Module polarities are shown in alarm. \ Refer to nanel documentation for 00 00 TO Next IIxxIXxi Device T OLk C2~ CONTLROL 0 UL M O:DULE 47K EOL Resistor 19 0 ELR-47K IL 1 - 7 TENS 4 t LOO ADDRESS UL listed [jj] EOL Relay I I • TO NEXT control module or EOL Relay. shown L • ONE RELAY REQUIRED for each circuit. pnp.r0i7pd I Some control panels have the RELAY BUILT IN type of cble required. FROM Panel or Previous Device 24 VDC Circui -'t /DO NOT LOOP wire on terminals 3 & 4. Break wire to provide IL supervision of connections. POWER SUPPLY Power Supply: Isolated, regulated, power-limited per NFPA 70. Listed for fire protection 24 VDC coil and do not require external wiring. With battery backup. - A77-716B Refer to the NOTIFIER manual. V Fig. 2 FCM-1: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Communication Line 32 VDC max. Module polarities are shown in alarm. \ Refer to panel documentation for type of cable required. FROM Panel (+) or Previous Device 24 VDC Circuit DO NOT LOOP wire —J> on terminals 3 & 4. Break wire to provide supervision of connections. Th2 VDC 1 POWER SUPPLY Power Supply: Isolated, regulated, power-limited per NFPA 70. Listed for fire protection with battery backup. DN-6724 04/05/04 - Page 3 of 4 NORMALLY OPEN 1 Mr Fig. 3 FCM-1: Typical wiring for speaker supervision and switching, NFPA Style V. Connect modules to Listed compatible Refer to panel documentation - - NOTIFIER control panels only. - Communication Line for type of cable required. TO Next 32 VDC max All wiring shown is supervised. Dev (+) or Previous (—) FROM Panel Wires must be supervised per NFPA. Device Module polarities are shown in alarm Audio Circuit / DO NOTLOOP wire I on terminals 3 & 4. 47K EOL / Break wire to ensure Resistor + ' supervision of connections. (—) 9- 6 391 + AUDIO AMPLIFIER LOOP ONLS DRESS 70.7 VRMS Max. Use only models AA-30, M-100, or AA-120. (+) Amplifier must provide TO Next wiring supervision per NFPA. Speaker Switching Circuit: NFPA STYLE W Control Module SUPERVISION Speakers must be listed for fire protection. Last module must return Refer to the Relay Contact Rating table for maximum load, wires for supervision. — 6724wir3.wnf V1 Fig. 4 FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised. Refer to panel documentation Wires must be supervised per NFPA. TO Next Communication Line for type of cable required. (—) Module polarities are shown in alarm 32 VDC max. FROM Panel Device or Previous EOL Resistor is internal at terminals 8 CONTROL Device Bypass Capacitors: A2143-20, 100 pf, MODULE Audio Circuit 16 V, non-polarized, < 10 pA leakage. 0 / DO NOT LOOP wire on terminals 3 & 4. Break wire to ensure supervision of connections. M 30 - r AUDIO AMPLIFIER 70.7 VRMS max. ONES LOO' ADDRESS Use only models AA-30,0, PID F-* AA-100. or M-120. r Amplifier must provide I wiring supervision per NFPA. TO Next Speaker Switching Circuit: NFPA STYLE X Control Module SUPERVISION Speakers must be listed for fire protection. Last module must return 6724wir4 wnf Refer to the Relay Contact Rating table for maximum load, wires for supervision. NOTE regarding AUDIO AMPLIFIER in Figures 3 & 4 above: 1) Audio circuit wiring must be twisted-pair as a minimum. See NOTIFIER installation manual for detailed information. TO Next Device *------ 0-1-1 RELAY —MODULELE RELAY COMMON 2 9 0 NORMALLY CLOSED 2 8 1 NORMALLY OPEN 2 7 —! H 2 RELAY COMMON 1 6 3 NORMALLY CLOSED 1 5 4 cs3 - Page 4 of 4 — DN-6724 . 04/05/04 F132VDC FROM Panel or Previous rn'catnUneDevice maximum. panel documentation f cable required. Fig. 5 FRM-1: Relay module wiring diagram. Connect modules to Listed compatible NOTIFIER control panels only. Module does NOT supervise controlled circuits. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, *FTM..1 monitor modules and Models FCM-1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. *Model FTM-1 is intended to be used with Notifier Models NFS-640 (CSFM Listing Nos. 7165-0028:214 and 7170-0028:216), NFS-3030, NFS2-3030 (CSFM Listing Nos. 7165-0028:224 and 7170-0028:223) Fire Alarm Control Units. *Rev. 07-12-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. - Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 - Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager July 20, 2004 DN-6927 E-30 ® I FCPS-24S6 and FCPS-24S8 N OT I F I E R 6-Amp and 8-Amp 24-Volt Remote Power Supplies I I Section: Power Supplies GENERAL The FCPS-24S6 (6-amp) and FCPS-24S8 (8-amp) are com- pact, cost-effective remote power supplies with battery charger. The FCPS-2456/-2458 may be connected to any 12- or 24- volt Fire Alarm Control Panel (FACP) or may be used as a stand-alone supply. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA re- quirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24S61-24S8 provides regulated and filtered 24 VDC power to four notifi- cation appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alter- nately, the four outputs may be configured as all non-resettable, all resettable, or two non-resettable and two resettable. The FCPS-24S6/-2458 also contains a battery charger capable of charging up to 18 AH batteries. FEATURES UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander 2" appliances. Cascadable for up to ten power supplies (four for Gentex) with strobe timing maintained. Operates as a "sync follower" or as a "sync generator" (de- fault). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumpered per- manently "ON" (stand-alone mode). Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. 6-amp (FCPS-2456) or 8-amp (FCPS-2458) full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp (FCPS-2456) or 6-amp (FCPS-2458) continuous out- put in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (A77-7168). In stand-alone mode, output power circuits may be config- ured as: resettable (reset line from FACP required), non- resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate or 8-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, locking cabinet— 15" (38.1 cm) high x 14.5" (36.83 cm) wide x 2.75" (6.985 cm) deep. Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. California L State Fire LISTED APPROVED 7315-0028:225 S635 MEA 299-02-E Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. STANDARDS and CODES The FCPS-2456/-24S8 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems (stand- alone mode). SPECIFICATIONS Primary (AC) power: FCPS-24S6/-2458: 120 VAC, 60 Hz, 3.2 A maximum. Wire size: minimum #14 AWG (2.0 mm2) with 600 V insulation. Control input circuit: Trigger input voltage: 9 to 32 VDC. Trigger current: 2.0 mA (16 - 32 V). Per input: 1.0 mA (9- 16 V). Trouble contact rating: 5 amps at 24 VDC. NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications ISO 9001 or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ENGINEERING & MANUFACTURING NOTI Fl E R' 12 Clintonville Road, Northford, Connecticut 06472 Q UALITY SYSTEMS DN-6927 07/20/04 - Page 1 at 3 Style Output Auxiliary power output: specific application power 500 mA maximum. Output circuits: +24 VDC filtered, regulated. 3.0 amps maximum for any one circuit. Total Continuous current for all outputs (stand-alone mode): for FCPS-24S6: 4.0 amps maximum: for FCPS-24S8: 6.0 amps maximum. Total short-term current for all outputs (NAC expander mode): for FCPS-24S6: 6.0 amps maximum; for FCPS-24S8: 8.0 amps maximum. Secondary power (battery) charging circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum charge current: 1.5 amps Maximum battery Capacity: 18 AH. APPLICATIONS Example 1: Expand notification appliance power an addi- tional 6.0 amps (FCPS-24S6) or 8.0 amps (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polar- ity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24-volt system power up to 4.0 amps (FCPS-24S6) or up to 6.0 amps (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *Addressable FACPs are capable of locating control and monitor Style Y NAC or modules at distances of up to Door Holder 10.000 feet (3048 meters). Power AGENCY LISTINGS Output #4 AND APPROVALS 4 SYNC FOLLOWER/GENERATOR NOTE In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-2456/-2458 can track (i.e follow') the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attached to the FCPS. When the FCPS-24S6/-2458 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync in- put terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-2456/-2458 is Configured (via DIP switch set- tings) as a 'sync generator," the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. PRODUCT LINE INFORMATION FCPS-24S6: 6.0 amp, 120 VAC remote charger power sup- ply. Includes main printed Circuit board, transformers, enclo- sure (15" [38.1 cm] high x 14.5" [36.83 cm] wide x 2.75" [6.985 cm] deep), and installation instructions. FC PS-2458: 8.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [38.1 cm] high 14.5" [36.83 cm] wide 2.75" [6.985 cm] deep), and installation instructions. ZNAC-4: Class A (Style Z) NAC option module. A77-71 6B: 12124 VDC end-of-line relay for monitoring four- wire smoke detector power. BAT-1270: Battery, 12 volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). PS-1270: Battery, 12 volt, 7.0 AH (two required, see PS Series data sheet DN-1109). NOTE: All NAC outputs can be convened to Style Z with ZNAC-4 option module. FCPS Trouble Y NAC Style Y NAG Style Y NAG Contact #3 Output #2 Output #1 Output See the first page of this data sheet for listing agencies and file 24 VDC numbers. These listings and ap- L Specific provals apply to the FCPS-2456 Application and the FCPS-2458. In some Power cases, certain modules or appli- AC cations may not be listed by cer- Power NAC Control . Input #2 tam approval agencies, or listing INPUT/OUTPUT (from FACP) may be in process. Consult fac- FUNCTIONS tory for latest listing status. are programmable by NAC Control SW1 DIP switch settings Input #1 (from FACP) Sync Input FCPS $r SIMPLIFIED Battery Charger BLOCK DIAGRAM Page 2 of 3 - DN-6927 • 07/20/04 BOARD LAYOUT TEl: Supervised Earth AC Neutral F_ AC Hot J2 0 4W r111 0 Auxiliary Output: 10 500 mA Specific- Application Power DJ7 3 24 1 =T SWI: Programming DIP Switches ON ..i 23 - - -Aux. Common - - + Aux. 24 VDC - - - Control Input 2 - - 1- Control Input 2 - - - Out Common - - + Out/Trouble Contact - - - Control Input 1 - - + Control Input 1 - - - Sync Input T SyncInput \JQ7•. Auxiliary Power utput is power-limited but NOT supervised. 'iI pIiiLI _____ . 1 II II II LJTIi Ground Fault _______ .JPI: Detection Jp '' J3 - J3: ZNAC-4 Connector JP2 & JP3: Coded/Non-Coded lnout Selection T62: Power-Limited, NAC/Out 1 + Supervised in NAC Mode NAC/Out 1 - with Jumpers J5, JP6, NAC/Out 2 + JP7, & JP8 in positions NAC/Out 2— shown below. NAC/Out 4- 87654321 Normally Open Normally Closed Common 1TB5: Trouble Relay 0 Form-C Fail-Safe (shown energized) Ift1(D 3 2 1 TB5 C,) o Non-Power-Limited J2: To Transformer #2 o Ji: To Transformer #1 0 0 Fl • 0I0 Fl: Battery Fuse 15A, 30V JP4 0 DD - Battery LEDs (L to R): + Battery AC Power (green) Ground Fault (ye/low) JP4: Supervised, Battery Trouble (ye//ow) Non-Power-Limited NAC Trouble (yellow) 18 AH, 24 VDC Charger Trouble/AC Loss (yellow) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0028:225 Page 1 of 1 CATEGORY: Power Units LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:206 1-24-2003K K This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager - ElA-485 Communication Bus Failure. Annunciation of UDACT Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Troubleshoot Mode converts keypad to DTMF touchpad. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kissoff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. Open Collector relay driver for Total Communications Fail- ure or UDACT trouble. Real-time clock. Extensive transient protection. Simple EIA-485 interface to host panel. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL Listed: S635 ULC Listed: CS100 Vol. VII MEA: 328-94-E; 317-01-E3 CSFM: 7300-0028:174; 7165-0028:214; 7165-0028:224; 7170-0228:216; 7170-0028:223 INDUSTRY CANADA: 2132 6030 A FCC: IWGUSA-20723-AL-E FM Approved (with Ademco 685 only; except NFS2-640, NFS-320, System 500, and System 5000) DN-4867:A • D-160 UDACT N OTI FR E R® Universal Digital Alarm Communicator Transmitter by Honeywell General r r The Universal Digital Alarm Communicator Transmitter r.itt (UDACT) is is designed for use on the Notifier NFS-3030, NFS2- 3030, AM2020/AFP1010, NFS-640, AFP-400/300, AFP-200/ 100, System 5000, and System 500 Fire Alarm Control Pan- els. In addition, it is also designed for use on the Intelligent Network Annunciator (lNA), software release 2.8 or higher. When used in conjunction with the lNA, NCA, and NCA-2 the UDACT can report the status of all control panels on NOTl'FIRE'NET. The UDACT transmits system status to UL listed Central Station Receivers via the public switched tele- phone network. The UDACT is compact in size and may be mounted externally in a separate cabinet. EIA-485 annunciator communications bus and regulated 24-volt connections are required. The UDACT is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT is capable of transmitting all of the zone and point sta- tus associated with each panel. Note that the AFP-100 requires UDACT revision 2.0 or higher. When the UDACT is used with the AM2020/AFP1010, NFS- 3030, NFS2-3030, NCA, and NCA-2 it is capable of reporting up to 2,040 points. Reporting may be in the form of points or zones (refer to the UDACT manual for specific reporting parameters). The first 568 points transmitted may be pro- grammed for a variety of types, including fire, waterflow, super- visory, etc. Remaining points transmitted are for fire alarm only. NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features Maximum of 14 point trouble messages transmitted per hour. Dual phone lines. Dual telephone line voltage detect. Surface Mount Technology. Compact in size: 6.75 x 4.25' (17.145 x 10.795 cm). Built-in programmer. Built-in 4-character red 7-segment LED display. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. - Independent zone trouble. - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Off-Normal. —12 or 24 hour test signal. - Abnormal Test Signal per new UL requirements. DN-4867:A. 11/14/06—Page 1 of 4 Installation When used with the AFP-100 or AFP-200, the UDACT mounts in the ABS-8RB or UBS-1 backbox. When used with the Sys- tem 500, the UDACT can not mount in the CAB-500 far-back position. When used with the System 5000, the UDACT can mount in any far back (front module with expander allowed) position of the CHS-4 chassis. When used with the NFS-3030, AM-2020, AFP-1010, NFS- 640, AFP-400, or AFP-300, the UDACT mounts in a CHS-4 or CHS-4MB module position. In all cases, the UDACT can mount remotely (up to 6,000 ft./ 1828.8 m) in an ABS-8RB or UBS-1 backbox. NOTE: Due to space considerations, the far-back of the CAB-500 position is NOT recommended. Communication Formats 3+1 Standard • 4+1 Standard • 4+2 Standard 4+1 and 4+2 Ademco Express • Ademco Contact ID NOTE: Ademco Contact ID must be used for independent zone reporting. Required Software AFP-100 EPROM = ALL AFP-200 English EPROM* = 73609 (or higher) AFP-200 Spanish EPROM" = 73618 (or higher) AFP-200 French EPROM* = 73617 (or higher) AFP-400 EPROM" = #AFP4R2.0 (or higher) NFS-320= ALL NFS-640 = ALL NFS2-640 = ALL System 500 EPROM* = 73611 (or higher) System 5000 EPROM" = 73610 (or higher) AM2020/AFP1010" = Release 6.6 (or higher) NFS-3030 = ALL NFS2-3030 = ALL NCA=ALL NCA-2 = ALL INA = 2.8 or higher NOTE: Presently the UDACT is not capable of AC Fall delay (per NFPA standards) when used with the AA series Amplifier, APS-6R Power Supply, or the XP Transponder. Type Mode Feature Ademco Contact ID format only) Use Type Mode to identify reports to Central Station as: Fire Alarm Burglary Supervisory 24 hour Non-Burglary Pull Station High Temperature Heat Detector Low Temperature Waterflow Low Water Pressure Duct Detector Low Water Level Flame Sensor Pump Failure Smoke Zone Electrical Specifications - Standby current: 40 mA. Current while communicating: 75 mA. Page 2 of 4— DN-4867:A • 11/14/06 Maximum current while communicating and with open collec- tor output activated: 100 mA. Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Ordering Information UDACT: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions, and mount- ing hardware. MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). ABS-8RB: Metal enclosure for externally mounting UDACT up to 6,000 ft./1828.8 m from host FACP. 9.94 H x 4.63' W x 2.50" D (cm: 25.248 H x 11.760W x 6.350 D). UBS-1: Metal enclosure. Includes viewing window and optional relay mounting capability. R-1 OE: SPDT Form-C relay. Contacts rated for 10 A @ 115 VAC. Connects to open collector relay driver. R-20E: DPDT Two Form-C relays. Contacts rated for 10A @ 115 VAC. Connects to open collector relay driver. FBD-1: Ferrite bead kit. Use for remote mounting only. ROM1-UDACT: EPROM upgrade kit. ABS-8RB for remote mounting [9.94"(25.2476cm)h x 4.63(11 .7602cm)W x 2.5'(6.35cm)D] S.Wfl,j UDACT shown in UBS-1 DN-4867:A • 11/14/06- Page 3 of 4 C —Ln ILL 0 C-4 C )= ° 0 00 ' _ 0 0.— CQ CW o cc C14 Format# — (1) 0 - &a o o (Addresses 16&42) E 4+1 Ademco Express ••• - - - - 1 4+2 Ademco Express X X X(8) X 2 3+1/Standard/1800/2300 X X(2) X X(4) X X(5,6)1 X X 3 (NOT USED) 4 3+1/Standard/1900/1400 X X(2) X(4) X X X 5 (NOT USED) 6 4+1/Standard/1800/2300 X X(2) I X I X(4) X X(5) X X 7 (NOT USED) 8 4+1/Standardl1900l1400 X X(2) X(4) X X X 9 (NOT USED) A 4+2/Standard/1800/2300 X X(2) X X(4) X X(5) X X B (NOT USED) C 4+2/Standard/1900/1400 X X(2) X(4) X X X D (NOT USED) E JAdemco Contact ID X X X X F (NOT USED) With 685-8 Line Card with Rev. 4.4d software. With 9002 Line Card Rev. 9035 software, or 9032 Line Card with 9326A software. Rev. 4.0 software. FBI CP220FB Rec-11 Line Card with Rev. 2.6 software and a memory card with Rev. 3.8 software. Model 6500 with Rev. 600 software. Model 6000 with Rev. 204 software. With Rev. B control card at Rev. 1.4 software and Rev. C line card at Rev. 1.5 soft- ware. Model 2 only. Version 1.62 software. NOTI-FIRE-NEI-Im is a trademark and Notifier® is a registered trademark of Honeywell International Inc. ©2007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so 000i This document is not intended to be used for installation purposes. ______________ We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINERINS A M11111FAC1URlNC QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 4 of 4— DN-4867:A • 11/14/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:174 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Model *UDACT digital alarm communicator transmitter with Model ABS-8R (optional) enclosure. The unit is used to transmit system status to central station via a standard two wire telephone switching network. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 21.2 - 28.2 VDC, 40 mA standby, 75 mA alarm, 100 mA trouble. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as digital alarm communicator transmitter for use with separately listed compatible control units. *Rec 4-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager COOPER Wheelock Series AS Audible Strobe Appliances and Series AH Audcjibles -77 - i: rl1: SERIES AS SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-24-8MC Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADA/NFPAIUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings otl5/30/75/95cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL Regulated Voltage Range' using filtered DC or unfiltered FWR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires For Weatherproof Series AS, See Datasheet S9004 / (10N-04 M I APPROVED E5946 151-92-E 7125-0785:131 55391 12 vdc 0.163 0.260 UL max" 0.192 0.320 dBA Med (95) 12 vdc 0.076 0.195 UL max" 0.108 0.275 dBA Low (90) 12 vdc 0.039 0.175 I_________ I UL max" 0.058 0.265 dBA I Table 3: Average RMS Current Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 1 5c 30cd 75cd llOcd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd High (99) 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 dBA UL max" 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 Med (95) 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 dBA UL max* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 Low (90) 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 dBA UL max" 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 12 VDC Models Audible Wall Mount Audible Strobe AH-1 2 AS-1 21575W Table 4:Average Current* (AMPS) For Series ASWP# Voltage Setting Setti High dBA Medium dBA Low dBA ng Setting (95) dBA (90) dBA 24.0 VDC 0.128 0.105 0.098 UL Max* 0.168 0.155 0.150 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS currentwithin the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU - AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate oil to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity 0193% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number Input, Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15 (75 On Axis) AS-121575W 12 8.0-17.5 15(75onAxis) AS-24MCC 24 16.0-33.0 15/30/75/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0-33.0 75@-31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/AR 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA Per UL 464 dBA @ 10 ft. © loft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Code 3 Horn Medium 84 95 Low 79 90 SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATU RE SM A NAC STROBE NAC 0— nu SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 F c ± 0- Audible NAC c DSM #2 A Strobe NAC Ci Sync C Au ible NASM#3 P Sync Strobe NAC Ci + Wiring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT PRECEDING APPLIANCE - APPLIANCE OR FACP OR EOLR SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-8CP and PS-12/24-8MP OUTPUTS EOLR 1-4 F 4-CLASS A OR AS Iss C 2-CLASS I E P Serieu PS-12/24-8CP or PS-12124-8MP SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE Specifications and Ordering Information DSM Interconnecting wiring shown. Maximum of twenty (20) For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-81VIC. Model Number Order Code Strobe Candela N Sync Sync w/SM, DSM or PS-24-8MC 24 VDC 12 VDC Wall Mount Mount Ceiling Agency Mounting Options*** Approvals AS-24MCW-FR 9024 15/30/75/110 X X X - X - A,B,DE,F,G,HJ,N,OR,X X X X x x AS-24MCW-FW 9025 15/30/75/110 X X X - - AIB,D,EIFGH,J,N,O,R,X X X x x x AS-24MCWH-FR 3468 135/185 X X X - X I - A,BDE,F,G,H,JN,OIR,X X x x x * AS-24MCWH-FW 3469 135/185 X X X - X - A,B,DEF,G,H,JN,OIR,X X X X x AS-241575W-FR 7405 15(75onAxis) X X X - X - A,B,DE,FGHJ,N,O,R,X X X X x x AS-121575W-FR 7410 15(75onAxis) X X - X X - AIB,D,EF.G,H,JNO,R,X X X X x x AS-24MCC-FR 3161 15/30/75/95 X X X - - X ABIDEF,G,H,J,N,OR,X X X x x AS-24MCC-FW 3162 15/30/75/95 X X X - - X A8,DE,FGH,J,NOIR,X X X x x * AS-24MCCH-FW 3467 115/177 X X X - - X A,BD.EFG,HJ,N,O,R,X X X X x * ASWP2475WFR** 9012 75 @ -31°F X X X - X - I (see Data Sheet S9004) X X x x x Al-I-24-R 7892 - X X X - X X ABD,E,F.GH,JNO,R,X X X X x x AH-24-W 7893 - X X X - X X A,BD,EFGHJNO.R,X X X x x x AH-12-R 7891 - X X - X X X A,BDEFGHJ,N,OR,X X X x x x AH-12-W 7894 - X X - X X X A,BDE:FGHJ.NOR.X X X K X X AH24WPR** 743 - X X X - X X K X X X x AH12WPR** 745 - X X - X X X K X I X I X **For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING ***Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock PS-24-8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash- rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com I WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S8100 AS/AH 06/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230,-2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -w are for wall mount only. Models AS-2415C, -24300, -2475C and -241000 audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDC/VFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MOW: Selectable 15cd, 30cd, 75cd, 110cd MOO: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. *Rev. 06-13-06 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when Used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager COOPER Wheelock Series RSS and RSSP Strobes and Strobe Plates FV1E r Series RSS Series RSSWP RSS Round L.j V. _k• Series RSS Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 1 5130175/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supplies with the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. ®1 MEA "V' APPROVED S5391 51-92-E 7125-0785:141 Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPNUFC/ANSI compliant. Meets OSHA 29 Part 19 10.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or power sup- plies with built-in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datat.sheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAiLURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Genera! Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP - Wall Mount RSS - Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 1 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP RSS/RSSP * RMS current ratings are per UL average RMS method. UL max Current 24VDC Wall Mountrating is the maximum RMS current within the listed voltage range (16-33v 121575W Models for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, 12 vdc 0.152 see installation instructions. UL max* 0.255 Table 2: Audi bles/S pea kers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 Wiring Diagrams # SERIES RSS/RSSP APPLIANCE FROM TO NEXT PRECEDING APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC SYNC CIRCUIT OUT 0.OLJT -IN IN I RSS RSS RSS MUS I 0+ ] AIIIDISL MINUS 2 0 INS RSS RSS ROBE • NAC OOUT2 CIRCUIT RETURN SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F 0 + STROBE 0 - STROBE A Strobe NAC Circuit C 0- Audibl P EOLR Audib1 SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12/24-8CP or PS-12/24-8MP Series PS-I 2/24-8MP F 1-4 EOLR OUTPUTS 4-CLASS A "B' AS NSA OR C 2-CLASS "A" P AS RSS Series PS-12/24-8M STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM _____ ______ + APPLIANCE PRECEDING I I I i - OR EOLR APPLIANCE SYNC MODULE POWER SUPPLY ORFACP + - STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM PRECEDING + + TO NEXT APPLIANCE OR _________ APPLIANCE IACP DR LOW - - FROM + - +.10NEXF PRECEBINC ;T11 STROBE OR STROBE. SYNC - - - - -- - - COLA NIOUIJLE. 'OWES SUPPLY OR FACP 0 +- STROBE APPLIANCE For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS- 12124-8CP and P84333 for PS-12124-8MP. - Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Non. Sync Strobe Candela 24 VOC 12 VDC Color RED Color WHITE Mounting Options* square or Round —Agency Approvals UL MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X x x RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X x RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X x x x RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X x x x RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X x x x RSS-121575W-FW 7468 X - X 15(75onAxis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X x x x RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round. X X X x * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X x x * RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X x x RSS-24MCWH-FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X x x * RSSWP2475WFR** 9013 X - X 180@ 77-F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X x x * RSSWP2475WFW** 3034 X - X 37 :FF X X - X B,D,E,F,G,H,J,N,O,R,X Square X X x x * RSSP-121575W-FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X x x x x RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X x x x RSSP-241 575W-FR 7793 X - X 15 (75 on Axis) - - X - D,E,Z Square X X x x *PENDING All models sync with Wheelock SM, DSM or PS-12/24-8CP or PS-12/24-8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet 37000 for mounting options. Architects and Ingineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet nd be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or the Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. to COOPER Wheelock 273 Branchport Avenue Long Branch, NJ 07740 If,'iu Phone: (800) 631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING- BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No, 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRSMCC *ZRSMCW *ZRSMCCH and *ZRSMCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 2416-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 3030cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRSMCW. Selectable 1 5cd, 30cd, 75cd or hOod RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRSMCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRSMCWH: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRSMCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. Rev 12-13-2006 iw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering stab has reviewed the tp results and/or other data but does not make an independent verificaiion of any claims This listing is not an endon rnent or - recommendation of the item listed This listing should not he used 10 verify correct operational requirements or Thiallation J/ criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources Date Ifsued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior DepLity State Fire tvlarsha/ Program Manager RSS Round LI']i Wheelock Series RSS and RSSP Strobes and Strobe Plates - - - 1t'--'--' -- - - RE . Series RSS Series RSS Series RSSWP Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30/751110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 1 5/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supplies with the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHEB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. <@> MEA '' APPROVED S5391 151-92-E 7125-0785:141 Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPNUFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/11Ocd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or power sup- plies with built-in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. a WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT, VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP - Wall Mount RSS - Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH Models 1575cd 15cd 30cd 75cd llOcd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd 24vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP RSS/RSSP * RMS current ratings are per UL average RMS method. UL max current 24VDC Wall Mountrating is the maximum RMS current within the listed voltage range (16-33v 121575W Models for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, 12 vdc 0.152 see installation instructions. UL max* 0.255 Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 Wiring Diagrams # SERIES RSS/RSSP APPLIANCE FROM TO NEXT PRECEDING APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE 0 NAC SYNC CIRCUIT OUT .OUT 1 ø'-IN RSS RSS RSS MINI'S 0+ - L ]ROBE AUDIEL MINUS 2 g IN 2 RSS SSRSS NAC + OUt' 2 CIRCUIT RETURN SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 e NAC SY ric Cir. i—I® + I RSS I I RSS I F DSM #2 A SyneNAC Ci..0 RSS RSS C DSM #3 - P Syn c RSS SS Strobe NAC DSM Interconnecting wiring shown. Maximum of twenty (20) 9b BE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM APPLIANCE pgECEDING t OR EOLR APPLIANCE SYNC MODULE, POWER SUPPLY OR FACP STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY PROSI PRYITYRINC + NEXT APPLIANCE OR - APPLIANCE PAUl' OR EOLR FROM + - - 1 1 - - - + 10 NEXI PRECEDING I STROBE OR - - - 1-t 1 1 - - STROBE, SYNC - EULR N IOOIILE. POWER SUPPLY OR PACP 1 - STROBE APPLIANCE 11 For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS- 12124-8CP and P84333 for PS-12/24-8MP. Specifications and Ordering Information SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F 0 + STROBE 0 - STROBE Strobe A NAC CiI'cuiL (71-.-FAUdjbl P EOLR Audibi SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12/24-8CP or PS-12/24-8MP Series PS-12/24-8MP OUTPUTS EOLR F 1-4 4-CLASS A "B" AS RSS OR C 2-CLASS "A" AS RSS Series PS-12/24-8M Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE' Mounting Options Square or Round - Agency Approvals UL [MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/751110 X - X - B,D,E,F,G,H,J,NO,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,GH,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X x x x RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,DEF,G,H,J,N,O,R,X Square X X X x x RSS-121575W-FW 7468 X - X 115(75onAxis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X x x x RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,EFG,H,JN,O,R,X Square X X X X * RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,NO,R,X Square X X x x * RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X x x * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,HJN,O,R,X Square X X x x * RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,E,F,GH,J,NO,R,X Round X X x x RSS-24MCWH-FR 3465 X X 135/185 X - X B,D,E,F,G,HJ,N,O,R,X Square X X x x * RSS-24MCWH-FW 3464 X X 135/185 X X B,D,EF,G,HJ,N,O,R,X Square X X x x RSSWP2475WFR** 9013 X - X 180@ 77-F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP2475WFW** 3034 X - X 37 :FF X X - X B,D,E,F,G,H,J,N,O,R,X Square X X x x RSSP-121575W-FR 7798 X - X 15(75onAxis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X x x x RSSP-241575W-FR 7793 X - X 15(75onAxis) - - X - D,E,Z Square X X x x x *PENDING All models sync with Wheelock SM, DSM or PS-12/24-8CP or PS-12/24-8MP. # Models are available in either Red or White, Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options, Arc FllteCts ana engineers The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or the Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. 00 COOPER Wheelock 273 Branchport Avenue ____________ Long Branch, NJ 07740 Phone: (800) 631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchporl Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRSMCC *ZRS.MCW *ZRS.MCCH and *ZRS..MCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 = 1 6-33VDC/FW R Candela 15=5cd, 1575=15/75cd on axis, 3030cd, 75=75cd, 110110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRSMCW: Selectable 15cd, 30cd, 75cd orll0cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRSMCC. Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRSMCWH: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRSMCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must he used. Refer to listee's Installation Instruction Manual for details. Rev 12-13-2006 i.v This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the hIt results and/or other data but does not make an independent verification of any claims This listing is not an endorslrnent or recommendation of the item listed. This listing should not he used to verify correct operational requirements or criteria. Refer to listee's data sheet, installation instructions and/or other smutable information sources. Dote Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager COOPER Wheelock Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories Description: Designed for life safety, performance and reliability, Cooper When used in conjunction with Wheelock PS-24-8MC Power Wheelock's cost effective weatherpoof notification appliances Supplies or SM/DSM Sync Modules, the Wheelock weatherproof include: appliances can be synchronized to meet NFPA 72 synchronization Weatherproof Appliances Series requirements. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync Strobes RSSWP protocol. MTWP horn strobe models are 4-wire appliances; the Horn Strobes ASWP strobes can be synchronized while the audible can be connected Horns AH24WP, AH12WP to a coded fire alarm system or can be set to produce any of eight Multitone Horn Strobes MTWP selectable tones. Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 Features: All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Coàper-Wheelock provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. 0 <*> MEA °°' APPROVED E5946 151-92-E 7125-0785:131 (ASWP) S5391 7125-0785:146 (ET70VVP) S2652 7125-0785:15e (MTWP) 7300-0785154 (RSSWP) Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP). See agency approvals by model number on page two of this document Compliance with the following requirements: NFPA, UFC, ANSI 117.1, OSHA Part 29, 1910.165, ADA Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 660C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Synchronization capability using Series SM, DSM Synch Modules (MTWP and MT-12/24 audible is non-sync) Models with field selectable tone, dBA and candela settings Wall or ceiling mounting options Surface of semi-flush mounting IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal *The series RSSWP, ASWP, MTWP and ET70WP have UL approval down to -40F. The AH-24WP, MT-12/24 and the ET-1010 have been ULC tested and approved to -40°F, but not submitted to UL. The AH-12WP has UL/ULC approval to -31F. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR 'OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount Ceiling Mount RSSWP MTWP RSSWP MTWP AI ASWP ASWP ET70WP Strobe Order Code Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR Red 5167 RSSWP-24MCWH-FW White 5165 RSSWP-24MCCH-FWWhite 5187 Audible Strobe Audible Strobe ASWP-2475W-FR Red 9012 ASWP-2475C-FR Red 4251 ASWP-24MCHW-FR Red 5137 ASWP-2475C-FW White 4502 ASWP-24MCWH-FW White 5140 ASWP-24MCCH-FR Red 5149 Multi-tone Strobe ASWP-24MCCI-l-FW White 5157 MTWP-2475W-FR Red 8420 Multi-tone Strobe MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457 MTWP-24MCWl-l-FR Red 5132 MTWP-2475C-FW White 4478 MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 Speaker Strobe MTWP-24MCCH-FW White 5122 ET70WP-2475W-FR Red 9077 Speaker Strobe ET70WP-2475W-FW White 3179 ET70WP-2475C-FR Red 4452 ET70WP-241 85W-FR Red 4885 ET70WP-2475C-FW White 4454 ET70WP-24185W-FW White 4891 ET70WP-24177C-FR Red 4845 ET70WP-24177C-FW White 4859 Candela Ratings Series UL 1971 @ 32°- 120°F UL 1638 © 77°F 1. MTWP UL 1638 © -40°F RSS, ET70WP and UL Max Current (Strobe Only) __________________ ASWP High _______ Med ______ Low ______ 2475 30 180 115 0.138 0.168 0.155 0.150 135 135 65 0.300 0.355 0.340 0.335 MCWH 185 185 90 0.420 0.480 0.465 0.460 115 115 50 0.300 0.355 0.340 0.335 MCCH 177 177 75 0.420 0.480 0.465 0.460 24185 185 185 90 0.420 24177 177 177 75 0.420 UL Max. Current (Audible) MTWP/MT 24 VDC MT 12 VDC IBA HI STD HI STD Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 Code 3 Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 j 0.035 Siren 0.104 0.036 10.1521 0.030 Hi/Lo 0.057 0.025 10.1141 0.026 Wall or Ceiling Mount MT AH ET-1010 Audible Order Code AH-24WP-R Red 7416 AH-12WP-R Red 7415 Horn MT-12/24-R Red 5023 Speaker ET-1010-R Red 3135 ET-1010-W White 3137 UL Max. Current AH 24 VDC 12 VDC High (99) dBA 0.080 0.192 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 UL Reverberant dBA@ 10 Feet Watts 1/8 1/4 1/2 1 2 4 8 ET-1010 77 80 83 86 87 92 94 ET70WP 78 81 84 87 90 93 95 Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X * RSSWP-24MCWH X RSSWP-24MCCH X * Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X * I * * ASWP-MCCH X * * * Multitone Strobe MTWP-2475 X X X X * MTWP-MCWH X * * * * MTWP-MCCH X Horns/Audibles AH-24WP X X X - X AH-12WP X X X - X MT-12/24 X X X X X Speaker Strobe ET70WP-2475 X X X * * ET70WP-185 X * * ET70WP-177 X * * * *pending Mounting Accessories WPSBB WPBB WBB Gasket Kit Order Code WP-KIT 4486 Flush Plates WFPA-R Red 4698 WFPA-W White 4701 WFP-R Red 4696 WFP-W White 4697 Backboxes IOB-R Red 5046 IOB-W White 5047 WPSBB-R Red 9751 WPSBB-W White 3033 WPBB-R Red 9014 WPBB-W White 4692 WBB-R Red 2959 WBB-W White 2960 Mounting Options: Backboxes, Plates, Gasket Kits Surface Mount Flush Mount Exposed Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WFP ET70WP Speaker Strobes lOB lOB + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA AHWP Horns WBB - WFP ET-1010 Speakers WBB - WFP MTWP Multitone Horn Strobes lOB lOB + WP-KIT WFP Multitone Horn lOB lOB + WP-KIT WFP Wiring Diagrams ROM _____ ______ + TO NEXT "RECEDING + RED APPLIANCE PPLIANCE - i BLACK _ )R FACP - OR EOLR STROBE AUDIBLE SERIES RSSWP, ASWP, AHWP, MTWP AND MT-1 2/24 APPLIANCES FROM + TO NEXT APPLIANCE I I - APPLIANCE OR OR EOLR FACP H SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP MTWP Strobe Sync 0 Circuit Module NAC#10 PS12/248 0 I J I Power nH- Circuit-+— I FACP Supply NACC2 Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED W/ DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBES +0 NACE SYNC - 0 CIRCUITO our 0+OUTIIN -0+11419 RSSB 0 MINUS 15 AU 018 LES 25 ØUS + IN 25 RSSO ROB NA1a OUT 2 5 CIRCUITh RETURN SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. t Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Rf(Ifl11U1. .MIVU =1VU11V=M1i WMAPIUAIIUP4 General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. To Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-24-8MC Power Supply with built-in, patented sync protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S9004 WP 03107 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W, audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -241 OOC audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. *Rev. 06.13-06 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0785:154 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Models RSSWP-2475W synchronous or non-synchronous strobe light. Model may be followed by two alpha or numeric characters indicating lettering and color, followed by W for wall mount. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Flash rate: 60 flashes/mm. Candela: 75 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model can be used outdoors when used with WPSBB back box only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a strobe light for use with separately listed electrically compatible fire alarm control units. For indoor or outdoor use. Intended for wall mount only. For synchronized strobes, Models SM-12/24, SMX-12/24 Sync Modules, DSM-12/24 or DSMX-12/24 Duel Sync Modules (CSFM Listing No. 7300-0785:1323) or power supply PS- 12/24-8 (CSFM Listing No. 7315-0785:149) must be used. NOTE: Not suitable for hearing impaired application. *Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager