Loading...
HomeMy WebLinkAbout6260 EL CAMINO REAL; ; FA100010; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA1 00010 6260 EL CAMINO Job Address: REAL Permit Type: FALARM Parcel No: 2131100100 Lot #: 0 Status: ISSUED Applied 3/9/2010 Approved: 3/9/2010 Reference No.: Issued: 3/912010 PC #: Inspector: Project Title: TRI-CITY WELLNESS MOB TI TWO FIRE ALARM INSPECTIONS @ $65 EA Applicant: SIMPLEX GRINNELL 3568 RUFFIN ROAD SAN DIEGO CA 858-633-9100 Owner: ECR CORPORATE CENTER LP C/O MONICA R BROWNING 5600 AVENIDA ENCINAS #100 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 CITY OF CARLS FIRE DEPARTh? APPROVE! Subject to field inspection and vequ1rci tests, notations hereon, conditions in correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to perm 01 11 e violation of; Ru Date Ia / SimplexGrinnell LP I F I 3568 Ruffin Road tijci ire & Si San Diego, CA 92123 Security I / Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com FIRE ALARM PRODUCT SUBMITTAL Tri City Wellness Complex Medical Office Building (MOB) TI 6260 El Camino Real Carlsbad, California 92009 These pbiii' ha' c heci' 1 Iewed lot appatelli e0i1lilt s lb he L hiTCh1 1 ,cahI codes and sLindards in loice ii he it siliC I Ofi 'Vile owner Or conhraciot Illaynob/e hi it' 1, 11 11, suppilil ot an application 1 ni a hu,iI pet nil s ith the e spresS 11,idersiaiidiutg that this evicts il fill Wa' FCIiC' et the Owner ni Or the,' ) pi olessi' nal engined or architect for sole csponsihitt tv lull eiiiilplii wlih said codes and standarlS. iiig the huildilig code or lot any responsihitlY tot. se deticleitCiCS. errors. o'llissi011s or negligetwe in the plans whcthet or not noted in this rcvlC'V- pate: RevicwCr) 0 RECOMMEND APPROVAL RECOMMD APPROVAL AS NOTED AVcotc 1/28/2010 REV.#: 0 PROJECT #: 480-402732-03/948793703 SirnplexGrinnell LP / / 3568 Ru if/n Road tLJCt3 / Fire & / S:mplexGr:nnell San Diego, CA 92123 I Security I Tale: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com FIRE ALARM SYSTEM PRODUCTS Item Description Model No A FIRE ALARM CONTROL PANEL (EXISTING) 4010-9101 DACT (EXISTING) 4010-9810 B NAC BOOSTER 4009-9201 C BATTERIES 6.2AH 2081-9272 D MANUAL PULL STATION 4099-9001 E SENSOR BASE 4098-9792 SMOKE SENSOR 4098-9714 F DUCT DETECTOR 4098-9756 SAMPLING TUBE 2098-9797 G IN-DUCT DETECTOR 4098-9751 SAMPLING TUBE 2098-9797 H HORN/STROBE MULTI-CD WALL 4906-9127 I STROBE MULTI-CD WALL 4906-9101 J INTERPOSING RELAY PAM-SD C.S.F.M. No. 7165-0026:226 7165-0026:226 7300-0026:214 N/A 7150-0026:224 7300-0026:217 7300-0026:218 3240-0026:241 N/A 3240-0026:220 N/A 7125-0026:317 7125-0026:316 7300-1004:101 1/28/2010 REV.#: 0 PROJECT #: 480-402732-03/948793703 SirnplexGrinnell LP 3568 Ruffin Road tijcti 'Fi Security re & / SimplexGrinnell San Diego, CA 92123 / Tele: (858) 633-9100 S Fax: (858) 633-9101 www.simplexgrinnell.com TAB# SYSTEM 1 FIRE ALARM 2 APPENDIX 1/28/2010 REV.#: 0 PROJECT #: 480-402732-03/948793703 5. Simplex T rueAlarm® Fire Alarm Controls UL, ULC, CSFM Listed; FM Approved; Model 4010 Fire Alarm Control Panel for TrueAlarm MEA (NYC) Acceptance* Analog Sensors and lDNetTM Addressable Devices S S I 4P I Standard features include: Up to 250 addressable TrueAlarm sensor or addressable device points using IDNet communications that operate with either shielded or unshielded twisted pair wiring** Four, 2 A notification appliance circuits (NACs) with solid state current protection Power supply/battery charger with 4 A available for NACs and auxiliary power Internal event reporting DACT module (standard on models 4010-9101, 4010-9102, & 4010-9150) UL listed to Standard 864 Installation convenience features: Power-limited design provides electronic modules on a one-piece chassis with up-front terminal blocks for wiring access Compact NEMA I rated cabinet is available in beige or red and can be pre-shipped for early installation Setup, programming, and maintenance features: Device level ground fault search, locate, and isolate Auto Program for general alarm operation TrueAlarm individual analog sensing with front panel information and selection access "Dirty" TrueAlarm sensor maintenance alerts, service and status reports including "almost dirty" Default TrueAlarm sensor device type operation TrueAlarm sensor peak value performance report Duplicate address error detection Front panel or PC programming WALKTESTTM silent or audible system testt Software verification simulation mode Supports the following IDNet devices: Addressable manual stations; TrueAlarm sensor bases, duct housings, and isolator bases Quad-state zone adapter modules (ZAMs) for initiating device monitoring Quad-state line powered individual addressable modules (lAMs) for initiating device monitoring and relay control 4009 IDNet NAC Extenders and TrueAlertC Addressable Controllers and accessories Available option modules include: Door mounted 24 LED annunciator (std. on ULC models) Network connection, or Point Reporting DACT Class A, NAC adapter module RS-232 ports for printer and maintenance PC Expansion power supply; Auxiliary Relay Module or City Interface Equipment for Suppression Release Applications (refer to data sheet S4010-0003) Compatible with Simplex® auxiliary panels: 4003 Voice Control Panel 4081 Battery Cabinet with charger for 50 Ah batteries LEi / 4010 Fire Alarm Control Panel (with standard door) 'srrintic TrueAlarm fire alarm control panels have the ability to provide location accuracy for monitoring and control. When equipped with TrueAlarm analog sensing for smoke and heat detection, the processing power of the control panel also has the ability to analyze conditions at each location to provide accurate detection with significantly reduced maintenance costs. The 4010 TrueAlarm Fire Alarm Control Panel has been specifically designed to provide addressable operation and analog detection in a cost-effective package for application sizes that previously were considered only appropriate for conventional zoned monitoring. Installation and Service Ease. The 4010 mounts on a single chassis for quick installation and removal. Terminal blocks are large and up-front for easy access and inspection. Optional modules are easily and quickly installed, and programmed as required. The 4010 cabinet provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting. Smooth cabinet surfaces are provided for locally cutting conduit entrance holes exactly where required. 4010 cabinets and electronics can be ordered separately, allowing early cabinet installation. Ground Fault Assistance. Ground fault problems often occur during installation. The 4010 provides isolating circuitry, control of isolator bases, and software-controlled sequencing to isolate ground faults to specific identified locations. This assistance helps the installer to accurately locate the wiring problem for quicker repair. * Refer to page 6 for listing details. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7170-0026:226 for allowable values and/sr conditions concerning material presented is this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safely Products Westminster. TrueAlarm analog smoke detection and IDNet addressable devices are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; 5,552,765; 5,552,763; DES. 377,460; 4,796,025; 5,966,002; and 6,034,601. WALKTEST system test is protected under U.S. patent #4,725,818. S4010-0001-10 2/2006 II[IIsi.IitiZI71Iiuiiiiii1iivj Extensive Feature List. The 4010 Fire Alarm Control Convenient Status Information. With the locking Panel provides access to an extensive feature list that door closed, a window allows viewing of the status includes: display. The 4010 status panel provides a two line by 40 Providing easy and powerful operator information with character, super-twist LCD information display and eight a logical, nienu-driven display status LED indicators as shown in the illustration below. Extensive and automatic diagnostics for maintenance From this display, the LED indicators will describe the reduction . general category of activity being displayed with the LCD History Logs available from the LCD or capable of providing more detail. For the authorized user, unlocking (optionally) being printed the door will provide access to the control switches and allow further inquiry by scrolling the display for Software Verification, allowing detailed logic additional detail. (Refer to control panel functional programming simulation to be conducted without illustration below.) activating connected outputs Control Panel (or service PC) label editing WALKTEST Diagnostic Operation Mode. The patented WALKTEST process allows a single person to Password access control perform system test. The system records test inputs such Auto Program Quick Configuration (Quick-CFIG) of as intentional alarms or trouble and either logs the connected modules and IDNet devices for general alarm response (silent WALKTEST operation) or outputs a operation to quickly get the system up and running brief, recognizable audible notification signal (audible WALKTEST operation). Extended Operator Control Panel Functions FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, remain on until reset THREE PROGRAMMABLE LEDs custom labeling (labels insert into 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 40 characters for custom label information [Provide a pocket), the top two LEDs are FIRST ALARM DISPLAY: Operation can be selected for maintained display of first 1 Jalarm selectable as red or yellow, the bottom LED is selectable as green or yellow until acknowledaed ___________________________________ / SYSTEM IS NORMAL 122t1rri - Mart 09—J':in--6 I - - CONTROL SYSTEM RESET restores PANEL VIEW with , control panel to normal when 4010 door closed : all alarmed inputs are r ,__•___••••__•____•___•_________•______ returned to normal 1LL I1ikF..I -\--- __ ALARM ACK acknowledges a Fire Alarm condition, \ NINE EXTENDED FUNCTION KEYS (accessible with logs the acknowledge and silences the operator \ door open) select and scroll through display prompts for panel and all annunciator tone-alerts \ locating additional system information, performing \ maintenance functions, or for front panel programming SUPV ACK acknowledges system supervisory I conditions, logs the acknowledge, and silences the \ I ALARM SILENCE causes audible notification appliances operator panel and all annunciator tone-alerts to be silenced, used after evacuation is complete and j while alarm source is being investigated TROUBLE ACK acknowledges system troubles, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts 1 0 S4010-0001-10 2/2006 TrueAlarm heat sensors can be selected for rate-of-rise detection as either 15° F (8.3° C) or 20° F (11.10 C) per minute with an independent fixed limit of 135° F (57° C) or 155° F (68° Q. TrueAlann heat sensors can also be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 1550 F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. To additional IDNet devices, up to 250 total 7 Modular TrueAlarm TrueAlert Addressable Controller sensor with base Supervised lAM Modular TrueAlarm sensor With IDNet isolator base Addressable station 4009 IDNet NAC Extender Quick-Connect Monitor ZAMs and TrueAlarm sensor I Relay lAMs 4010 Fire Alarm Control Panel with annunciator door 4010 Control Panel with Typical IDNet Devices I iI.I E*L11T' I IITJ1II IEY.1 [* TrueAlarm operation gives the 4010 system the ability to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 (National Fire Alarm Code) requirement for a test of the sensitivity range of the sensors is fulfilled by the TrueAlarn't ability to maintain the sensitivity level of each sensor. Modular TrueAlarm sensors use the same base and different sensor types (photoelectric smoke sensor, or heat sensor) can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. S S II. 1FTi Overview. The 4010 provides IDNet addressable device communications. Using a two-wire circuit, individual devices such as manual fire alarm stations, TrueAlarm sensors, and sprinkler waterfiow switches can be directly connected (or interfaced) to the IDNet controller to communicate their identity and status. This addressability allows the location and condition of the connected device to be displayed on the 4010 panel LCD and on system annunciators. Additionally, control circuits (fans, dampers, etc.) may be individually controlled by using a relay lAM (individual addressable module). The 4009 IDNet NAC Extender or the TrueAlert Addressable controller can be controlled for local or remote notification appliance expansion. (Refer to compatible device lists on document S4090-001 I and to individual device documentation for further details.) Capacity. A total of 250 addressable monitor and control points may be intermixed on the same pair of wires. By using Zone Adaptor Modules (ZAMs) or Individual Addressable Modules (lAMs), conventional initiating devices can be connected to the IDNet circuit. IDNet Addressable Operation. The IDNet controller continuously interrogates each addressable device on the communication channel for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Sophisticated poll and response communication techniques ensure supervision integrity and allow for "T-tapping" of the circuit for Class B operation. Wiring Requirements. Refer to the specifications chart below. Distances are for shielded or unshielded wire. Shielded wire may provide protection from unexpected sources of interference and may be required for some applications. Wiring Specifications Size 18 AWG (0.82 mm2 ) Preferred Shielded twisted pair (STP) Wire Unshielded twisted pair (UTP) Acceptable Farthest Distance from Control Up to 2500 feet (762 m) Panel to Device Total Wire Length Allowed With Up to 10,000 ft (3 km). "T" Taps for Class B Wiring IT! Fi i iiwTfl !II i-i TrueAlarm System Operation. IDNet communications are used for TrueAlarm smoke and temperature sensors. Every four seconds, smoke sensors transmit an output value based on their smoke chamber condition. The 4010 CPU maintains a current value, peak value, and an average value of each sensor's output. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Programmable Sensitivity. The sensitivity of each sensor can be field programmed at the 4010 Control Panel for different levels of smoke obscuration (in percent) or for specific heat detection levels. In order to evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read and compared to the alarm threshold directly in percent. S4010-0001-10 2/2006 TrueAlarm Information Details True Alarm sensor data can be displayed on the system LCD, on a remote maintenance PC, or printed on a remote printer. With the proper operator access, a TrueAlarm Service Report can be generated to list the specific details of each TrUeAlarrn device. This report as well as the Status Report can either be displayed on the remote maintenance PC or captured permanently by using a remote 80 character printer. Status and Service Reports. The report samples below illustrate the format provided on either the remcte maintenance PC or a printer. This information is available at the system LCD by identifying the specific point of interest and reading one point at a time. Compatible Printer. Model 4190-9013 is a UL Standard 864 listed 80 column, 24 pin dot matrix printZr (refer to data sheet S4190-001 1). (Model 2190-9039, a 24 VDC, 40 column printer, is compatible with the 40:0 for event printing only. Refer to data sheet S2190-0014.) Printer cSimplex model 9013) ri Local FI I I maintenance computer tIIlIiIiiIiRiOIiIiiIIiiiiRiIIiIiitIViHiliIRIIiIIIII.j ~'__ A ~'j 4010 Fire Alarm Ore connection type per 4010, Control Panel 1,seected by module choice; max. wfting distance is 300 ft (91 rn) @ 9600 baud Renote authorized maintenance computer connected via dial-up Seriie Modem Connection P5-232 Connection Options (refer to module saection on page 6) TrueAlarm Status and Service Report Samples Simplex 4010 Fire Alarm System Page 1 REPORT 3 : TrueAlarm Status Report 2:43:03 pm Non 09-Jan-06 Zone Sensi- Almost Name Custom Label tivity Device Status Dirty Ml-1 ANALOG PHOTO CLEAN ROOM 0.5 % NORMAL M1-2 ANALOG ION CLEAN ROOM 1.3 % NORMAL M1-3 ANALOG PHOTO MAIN LOBBY 2.5 % NORMAL *YES* M1-4 ANALOG PHOTO CONFERENCE ROOM 1 2.5 % NORMAL M1-10 HEAT DETECTOR GARAGE 135 F NORMAL MI-11 ANALOG PHOTO KITCHEN 3.7 % NORMAL END OF REPORT Typical TrueAlarm Status Report liformation Printout and/or Ma0itenance PC Screen Simplex 4010 Fire Alarm System Page 1 REPORT 4 : TrueAlarm Service Report 2:56:09 pm Mon 09-Jan-06 Dev Alarm Avg Curret/ Peak/ State Num Custom Label at: val % alarm % alarm 1 ANALOG PHOTO - CLEAN ROOM 0.5.' 83 67 68/ 11 72/ 10% NOR 2 ANALOG ION - CLEAN ROOM 1.3209 94 97/ 2% 101/ 1% NOR 3 ANALOG PHOTO - MAIN LOBBY 2.5.185 117 117/ 0% 125/ 42% NOR 4 ANALOG PHOTO - CONFERENCE ROOM 1 2.5-161 93 93/ 0% 93/ 0% NOR 10 HEAT DETECTOR - GARAGE 135F;253 --- 631-671 66/ 69F NOR 11 ANALOG PHOTO - KITCHEN 3.7.'216 116 116/ 11. 110/ 36% NOR END OF REPORT Typical TrueAlarm Service Report Information Prntout and/or Maintenance PC Screen 4 S4010-0001-10 2/2006 I S f117I TT I Mmm N2 Communications for Serial Annunciator Control. Control for up to 6 remote Simplex Annunciator products including 24 Point I/O Module, and LCD Annunciator. Includes extensive troubleshooting diagnostics. (See list in next colunin for compatible devices.) Access Port. RS-232 service port for connecting PC tools for service diagnostics and for programming the CPU Flash EPROM memory. IDNet Addressable Communications Channel. Addressable channel provides communications for up to 250 remote addressable devices, including TrueAlarm analog sensors and isolator bases (see details on page 3). Four NACs. Class B output is standard, rated for 2 A 24 VDC nominal, with solid state current protection. Class A operation is optional with the addition of an adapter module. NAC operation can be selected for "on-until-Silence" or "on-until-Reset," and can be Continuous, Temporal pattern, or March Time pattern. (March Tune is selectable for 20 bpin or 120 bpin for conventional appliances; or 60 bpin for SmartSyncTri appliances.) NACs are individually selectable to control Simplex synchronized strobes or for Simplex SmartSync control that provides separate horn and synchronized strobe control using a 2-wire circuit. (Class A, SmartSync circuits require SmartSync Control Module 4905-9938, refer to data sheet S4903-001 0 for details.) Two Auxiliary Output Circuits. Operation is programmable for trouble, alarm, supervisory, or other fire response functions. Output is one Form "C" dry contact each, rated 2 A @ 24 VDC. An optional relay kit is available for switching up to 0.5 A at 120 VAC. Standard Power Supply. Output is rated 4 A for "Special Application" appliances and for "Regulated 24 DC" appliance power. (Special Application appliances include Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, horn/strobes, and speaker/strobes. See page 7 for additional information.) Internal system power is provided separately, allowing the 4 A to be available for NAC and auxiliary power tap junctions. Over-current protection is solid state and self-resetting. Auxiliary Power Tap. Provides up to 0.5 A of the standard power supply voltage, over-current protected. Compatible uses include power for: remote LCD annunciators, 24 Point I/O modules, sensor bases and duct housings that require external power, and addressable devices requiring external power. Battery Charger. Capable of charging up to 25 Ah sealed lead-acid batteries (4010 cabinet mounted). A recharge time of 24 hours is typical with stable 120 VAC input. For applications requiring larger batteries, external charger/cabinet assemblies are available. A depleted battery cutout feature is programmable to advise and/or to reduce current when battery voltage is low. I :i .i u-i 1I1 I M rn ri (The 4010 is available with a Simplex Network Interface. 4010 points can be declared "public.") Network Interface, Fixed Media. Available for wired applications. I :i !I1 ui-i M1 m Network Interface, Modular Media. Available for wired connections or fiber optic. Require separate media modules. May be both wired, both fiber optic, or one of each. DACT, Point Reporting Module. Provides serial output infornrntion that can send location details to a remote receiving station. DACT, Event Reporting Module. For applications where simple event status information is required (Alarm, Trouble, Supervisory, and AC power failure). Dual RS-232 Module. Available for interfacing to a printer and a maintenance PC. Single RS-232 Module with Service Modem Connection. Provides one port dedicated for connection to a printer, and a second port dedicated for dial-in from a service computer, typically located off-site. With an off-site computer, programming changes and system diagnostics can be perfomied remotely, reducing service time for repair or reprogram. Security is maintained by password protection. 4 A Expansion Power Supply provides two taps of 2 A each, 28 VDC, filtered, non-regulated. Output rating is 4 A for auxiliary power, 4 A for "Special Application" appliances and 2 A for "Regulated 24 DC" appliance power. Battery Meter Module provides panel mounted ammeter and voltmeter for power supply monitoring. Dual Circuit Class A NAC Adapter Module mounts on the main 4010 printed circuit assembly and provides the additional circuitry needed for Class A operation. Dual Circuit City Connect Module provides the interface required for direct wired reporting to conventional city connection circuits. (Available with or without disconnect switches.) Expansion Power Distribution Module provides two additional termination points for the 0.5 A auxiliary power outpLit, or for one tap of the expansion power supply. Relay Option Module provides three relays, one each for Alarm, Supervisory, and Trouble. Relay contacts are selectable for normally open or normally closed and are rated 2 A @ 32 VDC maximum. I 1.iuui ul! Iii I Up to six of the following modules may be connected to the Simplex N2 serial communications bus. 4606-9101 LCD Annunciators provide remote acknowledge, reset, and alphanumeric status display. (Refer to data sheet S4606-0001.) 24 LED Annunciator Doors are standard on ULC listed models and are available as door-only assemblies for electronics only packages or other aftermarket applications. This option uses the 24 Point I/O module with all points pre-assembled as LED outputs, with individual labels and each LED is selectable as red or yellow. 4605 Series 24 Point I/O Modules are available for remote mounting and provide 24 points that can be programmed as either general purpose switch inputs or system controlled outputs. Typical applications are for remote annunciators and monitoring and control of other related processes. (Refer to data sheet S4010-0002.) S4010-0001-10 2/2006 [['ill WTV-3 ne &M FN Mr,111i riiiirm rirnrnmZIM I Description Voltage Color Listed 4010 Fire Alarm Control Panel with: door, cabinet, power 120 VAC Beige supply/battery charger, IDNet interface, 4 NACs, 2 programmable Red auxiliary relays, and external N2 communications interface; 4010-9101 Beige and 4010-9102 include internal common event reporting DACT 240 VAC Red English ULC Listed 4010 Fire Alarm Control Panel; same as above 120 VAC Beige French except: with 24 LED Annunciator door; and without DACT UL Listed I 4010 Fire Alarm Control Panel, Electronics Only; for pre-shipped ULC I English cabinets, requires door and cabinet ordered separately; 120 VAC input; I Listed French I 4010-9150 has event reporting DACT; C & CF suffix models delete DACT Category Control Panel Assembly (select one) 4010-9101 4010-9201 4010-9202 4010-9101C 4010-910 iCE 4010-9150 4010-9150C 4010-9150CF Optional Expansion Slot Features (two slots are available, select modules as required) Category Reporting and Network Modules b e -9810 <Zr Description DACT Module (Common Event Reporting) Includes two, 7 ft (2.1 m) long RJ45 cables DACT Module (Point Reporting) ___T8116- (select one) 4010-9821 Network Interface Module with fixed, wired connections 4010-9817 Network Interface Module, Modular; requires 2 (In/Out) media modules (see below) Media Modules 4010-9818 Network Wired Media Module Media modules mount on the 4010-9817 module Network Fiber Optic Media Module without impact to slot allocation space. 4010-9819 RS232 Communications 4010-9811 Dual RS-232 Interface Module (select one) 4010-9812 Single RS-232 Interface Module with Service Modem connection Chassis Mounted Expansion Modules (select as required) Category Model Description Expansion Power Supply 4010-9813 120 VAC input 4 A Expansion Power Supply; rated 4 A for "Special Application" appliances; 4010-9823 (select one) "Regulated 240 VAC input rated 2 A for 24 DC" appliance power 4010-9820 Battery Meter Module (ammeter and voltmeter) Optional Features (select one) 4010-9825 24 VDC Expansion Power Distribution Module, provides two additional termination points for an expansion power supply tap or the auxiliary power output 4010-9806 Dual Circuit Class A NAC Adapter Module, two maximum Optional Features (select as 4010-9809 Dual Circuit City Connect Module I I indicated) 40109829* Dual Circuit City Connect Module w/o disconnect switches Select one I maximum 4010-9803 Relay Option Module Accessories Category Model 4010-9826 Description 120 VAC Auxiliary Relay Kit, allows one auxiliary relay to control up to 0.5 A @120 VAC, select as required; 2 maximum Optional Features 4010-9830 (CAF) Suppression Release Appliqué, required for suppression release applications; suffix CAF selects a French appliqué 2975-9801 Semi-flush trim, beige, 1-7/16" (37 mm) wide 2975-9802 Semi-flush trim, red, 1-7/16" (37 mm) wide Batteries 2081-9272 6.2 Ah Battery, 12 VDC (required if 2081-9274 10.0 Ah Battery, 12 VDC batteries are internal; select one 2081-9288 12.7 Ah Battery, 12 VDC size; two batteries 2081-9275 18 Ah Battery, 12 VDC; NOTE: This battery size will not allow bottom entry conduit are required) 2081-9287 25 Ah Battery, 12 VDC Cabinets (select one if pre-shipped) 2975-9215 Red Cabinet Dimensions: 22" H x 18" W x 5-3/8" D Beige Cabinet; CF suffix has French labels (559 mm x 457 mm x 137 mm) 2975-9214(CF) Doors (select one if pre-shipped or for use with 4010-9150) 4010-9858 Red Door with dress panel Dimensions: 22" H x 18" W x 5/8" D Beige Door with dress panel; CF has French labels (559 mm x 457 mm x 16 mm) 4010-9857(CF) 4010-9860 (CAF)* Beige Door with 24 LED Annunciator and dress panel; Dimensions: 22" H x 18" W x CAF suffix selects French for ULC applications 1-23/320 (559 mm x 457 mm x 1 Red Door with 24 LED Annunciator and dress panel 44 mm) [see also 54010-00021 40109861* As of document revision date: 4010-9829 is not ULC listed; 4010-9860 and 4010-9861 are listed by UL, ULC, and CSFM; and FM approved; 4010-9860CAF is ULC listed and FM approved only. 6 S4010-0001-10 2/2006 C S S S 4010 Operating Specifications Input Power Requirements AC Input, 120 VAC base models Voltage Range 102 to 132 VAC Frequency 60 Hz Maximum Current 2 A AC Input, 240 VAC base models 204 to 264 VAC 50/60 Hz 1 A AC Input with 120 VAC expansion power supply 102 to 132 VAC 60 Hz 4 A AC Input with 240 VAC expansion power supply 204 to 264 VAC 50/60 Hz 2 A Environmental Operating Temperature Range 32° to 120°F (0° to 49° C) Operating Humidity Range up to 93% RH, non-condensing © 100.4° F (38° C) maximum Output Ratings Rated 4 A for "Special Application" appliances and for Standard Power Supply Output "Regulated 24 DC" appliance power; Battery charger for up to 25 Ah sealed lead-acid batteries Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, and Special Application combination horn/strobes and speaker/strobes (contact your Simplex Notification Appliance Reference product representative for compatible appliances) Power for other appliances listed to UL Standard 1971 or UL Standard Regulated 24 DC g 464; use associated external synchronization modules where required Auxiliary Power Output Tap from Standard Power Rated 0.5 A maximum © 19.4 to 32 VDC; Supply subtract current used from standard power supply output Rated 4 A for "Special Application" appliances and auxiliary power; Expansion Power Supply Output Rated 2 A for "Regulated 24 DC" appliance power; Two output taps of 2 A each are provided NAC Ratings 2 A each maximum; up to 33 synchronized strobes maximum per NAC Current Ratings for Optional Modules and Remote LCD Annunciator Model 4010-9810 Module DACT (Common Event Reporting) Supervisory 40 rn 440 4u jiA Alarm ~mA 0 mA 4010-9816 DACT (Point Reporting) 4010-9821 Network, wired communications 125 mA 125 mA 4010-9817 Network Modular, add media cards separately 24 mA 24 mA 4010-9818 Network Wired Media 47 mA 47 mA 4010-9819 Network Fiber Optic Media 36 mA 36 mA 4010-9811 Dual RS-232 75 mA 75 mA 4010-9812 Single RS-232 with Service Modem 100 mA 100 mA 4010-9806 Dual Class A NAC Adapter 0 mA 0 mA 4010-9809 Dual Circuit City Connect 20 mA 36 mA 4010-9829 Dual Circuit City Connect w/o disconnect switches 20 mA 36 mA 4010-9803 Relay Option Module 10 mA 37 mA 4010-9860 4010-9861 & ULC 4010s 24 LED Annunciator door 60 mA 83 mA (all LEDs on) 4606-9101 Remote LCD Annunciator (refer to data sheet S4606-0001) 65 mA 140 mA System Current (supplied separate from power supply output) Base System with: no IDNet devices Supervisory 195 mA Alarn j ---. ( 2b mA WOW k 50 IDNet devices 23u IA 100 IDNet devices 265 mA 365 mA 150 IDNet devices 300 mA 400 mA 200 IDNet devices 335 mA 435 mA 250 IDNet devices 370 mA 470 mA ** Current Calculation Information: To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. S4010-0001-10 2/2006 Standard door profile - (40 mm) 1-19/32"—P.:, - m) 'Annunciator ,, 2" mm) (19 mm) door profile Wall thick oss guides for ri 1/2" • (13 m-) wall board / ----------- - Typical conduit entry area (cut holes as required) —18"(457 7-3/32" (180 6-1/4 (159 m H(140r mm) S 4010 Module Layout Reference [1 EXT 02 o iDNet NAG, Ow? NAC3 NAG4 9 9 Expansion Slots 1 & 2 10 ~__l 7_7 LTho 'Atutamft [ill [illTBU P2 o, '0 TB? 1 4010-9820 4010-9809 Meter Module I III liii 4010-9806 : 4010-9806 n or-9829 or I I I I III Class A Class A City Module 4010-9825 I liii , Module Module or 24 VDC Power -9803 ' Distribution Relay Module , , Block : - 0 0 ETJ 4010-9813 or o C= - 40109823 - Expansion Power Supply © MW MW MW A"M Mounting Information POWER 21" (533 n- -------------------------------- 14-1/2" (368 mm) Battery Area No conduit entry or wiring in this area A.).:] Shaded area is for non-power limited wiring kWallthickrzss guides for 5/8 (16 mm) wall board) Internal straps are Annunciator Door, provided for wiring 1-23/32" (44 mm) thick management r (2 each side) Door and exposed ------ cabinet dimension - for semi-flush mount 2-15/32' (63 mm) ,Knockout s:-.-ew/nail holes (for semi-flush mount) Wall board position reference-_ for semi-flush mount Ttio, Simplex, the Sinzp/e.c logo, TrseA/ais - WALKTEST, IDNet, S,nai-tSvnc, and Ti-seA/en are trademarks o/ Tvco InlernationalAG or its a/fl/ia/es in 1/re U.S. c"d/or other cosntnies. NFPA 72 and National Fire Alarnr Code are registered tradeniarks of the National Pu-c Protection Association (NFPA). 93 co Safety Products Westminster• Westminster, MA 01441-0001 USA S4010-0001-10 2/2006 ci -mplex Ty www.tycosafetyproducts-usa-wm.com 02006 Ti'err Sa/ktt' P,oc/oct,c Westrnins-le,t A/I rights reserved. All specifications and other ir?toi'mation shout, were current as o/docrnnent revision date and ore subject to cnange without its/ice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:226 Page 1 of 2 CATEGORY: Fire Alarm Control Unit (Commercial) LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 pmattem@tycoint.com DESIGN: Models 4010-9101, -9102, -9201, and —9202 fire alarm control units. Power limited, automatic, manual, local, auxiliary, remote station (protected premises), proprietary (protected premise), watertlow, and sprinkler supervisory service. Suitable for releasing device service. Refer to listee's data sheet for detailed product description and operational considerations. System components: < 4010-910 -9102,-9201,-9202 Control Unit 4OT0 Standard Function I/O 29 City Circuit Card Event Report DACT 4010-9816 Point Report DACT 4010-9817 Modular Network Interface 4010-9821 RS-485 Net Interface 4010-9806 Class A Adapter 4010-9811 Dual RS-232 Interface 4010-9812 RS-232 Service Modem 4010-9813 Expansion Power Supply 4010-9814 Suppression Release Kit S 4010-9818 Wired Media Module 4010-9819 Fiber Optic Media 4010-9820 Battery Meter Module 4010-9823 Expansion Supply 4010-9824 Suppression Release Kit 2081-9046 Coil Supervision Module 4010-9860, -9861 Replacement Door with Annunciator 4010-9803 Relay Module RATING: 120, 220, 240 VAC primary; 24 VDC secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. *Rev. 01-15-09 bh 0 Listing No. 7165-0026:226 Page 2 of 2 APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Also suitable for high-rise application when installed with Model 4003 Series Voice Evacuation System (CSFM Listing No. 6911-0026:196). Refer to listee's Installation Instructions Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, g1h Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum - Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly from 71700026:226* *Rev. 01-15-09 bh This listinc is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results .ndlor othar data but does not make an independent verification of any claims. This listing is not an endorse-ient or recommendation of the item listed. This listing should not be used to verify correct operational requirements o installation criteria. Reer to listee's data sheet, installation instuctions and/or other suitable information sources. Dote Issued: MAY 8, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator S Fire Engineering Division S S S 5Simplex LifeAlarm® Fire Alarm Controls UL, UL C, CSFM Listed; FM Approved; 4009 lDNetTM NAC Extender for Control from 4010 or MEA (NYC) Acceptance* 41 OOU IDNet Communications; or from Conventional NACs IItiic Provides additional notification appliance circuit (NAG) capacity with flexible operation modes and power-limited design Four, Class B (Style Y) NACs are standard: Rated 2 A each for conventional reverse polarity 24 VDC notification appliances and providing multiple operation modes Can be selected to provide synchronization for Simplex ° visible notification strobe flashes Capable of controlling TrueA!ertv non-addressable notification appliances operating with SmartSyncTM two-wire control mode** Input control options: Up to 8 NACs 4009 IDNet NAC Extender - Optional IDNet Channel Repe I IDNet addressable communications from a Simplex 2-Wire IDNet model 4010 or 4100U Fire Alarm Control Panel** Cs or I Or from one or two conventional 24 VDC NACs with Fiber Optic IDNet I Communications or \ multiple output control options NAC Control IDNet communications control benefits: Provides status monitoring and individual NAC control iu IDNet Fiber using a single address per 4009 IDNet NAC Extender Optic Transmitter Supports IDNet "Device Level" earth fault location TIM M operation is available with either 4010 (shown) or choice 41000 Fire Alarm input Control Panel Internal 8 A power supply/battery charger: Charges internal batteries up to 12.7 All or up to 18 Ah batteries in external cabinet Provides status monitoring of battery, input power, and earth faults Rated 8 A for "Special Application" appliances; including Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, horn/strobes, and speaker/strobes Rated 6 A for "Regulated 24 DC" appliance power Optional 4009 IDNet NAC Extender modules: IDNet Communications Repeater provides Class B (Style 4) or Class A (Style 6) output IDNet Communications Fiber Optic Receiver/Repeater, available as Class B or Class A Four additional Class B NACs, rated 1.5 A for Special Application appliances; 1 A for Regulated 24 DC appliance power Class A (Style Z), Two Circuit Adapter Module UL Listed to Standard 864 I TV RTMI!T.-/T.l IDNet communication fiber optic transmitters: For applications requiring the data integrity available with fiber optic communications Available as Class B (Style 4) or Class A (Style 7) Mounts in standard six-gang electrical box External battery cabinet for 18 Ah batteries Simplex WALKTEST service testing is protected under U.S. Patent No. 4,725,818. Fire Alarm Control Panel with Conventional NACs 4009 IDNet NAC Extender Connection Reference Drawing rnr rrrtri ADA Compliance. Complying with the notification requirements of ADA (Americans with Disabilities Act) may require more notification appliance power than is available within the fire alarm control panel. When additional power is required, a Simplex 4009 IDNet NAC Extender can provide up to 8 A of NAC power with up to eight, supervised reverse polarity NACs. Location Flexibility. The 4009 IDNet NAC Extender can be mounted close to a compatible dedicated host panel or can be located remotely for convenient power distribution. Multiple operation modes and multiple connection options further increase location flexibility. Additional Information. For additional operation detail and application information, refer to Installation Instructions 574-181 and field wiring diagram 842-068. * ULC listed model is 4009-9202CA This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:214 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E, Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** SmartSync horn/strobe operation is protected under U.S. Patent No, 6,281,789. IDNet addressable communications are protected under U.S. Patent Nos, 4,796,025; 5,966,002; and 6,034,601. 4100U requires revision 11 software or higher for compatibility. 4010 requires revision 2 software or higher for compatibility. S4009-0002-6 8/2009 IDNet Addressable Communications Compatible. Up to five, 4009 IDNet NAG Extenders can be controlled on a single IDNet communications channel. Each output NAG can be individually controlled for general alarm or selective area notification requiring only one point address per Extender. Individual Extender NAGs can also be manually controlled from the host panel. IDNet controlled extenders will inform the host panel of troubles via IDNet communications. 4100U control panels control using multi-point rules, refer to data sheet S4090-0011 for details. Optional IDNet Repeaters. IDNet communications can be repeated with the optional IDNet Repeater Module or with the optional Fiber Optic Receiver Module. Up to 100 of the IDNet channel points can be repeated once (refer to pages 3 and 5 for details). Repeated IDNet communications also support the "device level" earth fault location utility of the host panel. Hardwire Control Applications. For applications where an existing (or new) conventional NAG needs additional power, the 4009 IDNet NAG Extender can be controlled directly from the NAG. Either one or two NAGs, from either the same, or from different host fire alarm control panels, can be connected to control the 4009 IDNet NAG Extender output NAGs. Multiple control selections provide flexible operation. (Refer to page 4 for more detail.) Alarms from the host panel will activate the four, 4009 IDNet NAG Extender NAGs (or optionally, eight NAGs) to extend the alarm. The 4009 IDNet Extender monitors itself and each of its output NAGs for trouble conditions, including earth faults. Extenders wired to conventional NAGs will indicate a trouble by opening the path to the NAG's end-of-line resistor, but retaining the ability to respond to alarms. Individual troubles are also annunciated by LEDs located on the 4009 IDNet NAG Extender main circuit board. (Refer to page 7 for more diagnostic information.) S Product Selection Standard Models - Description 99iiH 120 VAC input 40 r2iC 4009-9301 * ULC listed model 4009 IDNet NAC :Kender with 4, Class B (Style Y) NACs and 8 A power supply Optional Modules (for on-site installation) Model Description Comments Additional four point NAC module, rated 1.5 A Special 4009-9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power, Class B (Style Y), 4009-9808 Dual Class A (Style Z) adapter (for two N,C outputs) Select as required (4 maximum) 4009-9809 IDNet Repeater, output is Class A (Style Si or Class B (Style 4) Select either an IDNet Repeater or a Fiber Optic Receiver as required Class A (Style f fica, Style 6 IDNet) 4009-9810 Fiber Optic Receiver Class B (Style 4) 4009-9811 - 4009-9805 Red Appliqué for door Select if required 2975-9801 Semi-Flush Trim Kit Beige trim 1-7/16" wide (78 mm), use if required for semi-flush installations 2975-9802 Red trim Battery Selection (select battery size per system requirements) Model Description 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC 2081-9288 12.7 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC External Accessories (select per system requirements) Model Description 4090-9105 IDNet Fiber Optic Class B (Style 4) operation 4090-9107 Transmitter Class A (Style 7) operation 4009-9801 External battery cabinet for up to 18 Ah batteries, beige Comments Two batteries are required, 24 VDC operation Requires external battery cabinet, two batteries are required, 24 VDC operation Comments Mounts in six-gang electrical box, refer to page 4 for mounting details 16-1/4" W x 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) 4081 Series I End-of-Line Resistor Harnesses; see data sheet S4081-0003 for details S4009-0002-6 8/2009 S Typical IDNet Connection Example Typical IDNet compatible devices (Refer to individual devices for actual wiring - . requirements, some wiring is not shown.) ______________ I IDNet addressable communications channel, shown Class B (Style 4) Conventional NAC operation (horns) Output NACs, four standard, eight with expansion option i - Select conventional - - - or SmartSync operation per NAC 4100U (shown) or 4010 Fire Alarm Control Panel _ SmartSync operation (horns and strobes) ,-- 4009 IDNet NAC Extender with j Conventional NAC optional internal IDNet Repeater I L Li operation (strobes) Repeated iOftt Channel: up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to five (5) 4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections Two fiber cables, 3000 ft 4090-9105, Class B (914 m) maximum distance (Style 4) Output Fiber Optic Transmitter 4010 or 41001-1 Fire Alarm Control Panel IDNet addressable communications channel Class B (Style 4) or Class A (Style 6), Class B shown Four fiber cables, 3000 ft (914 m) maximum distance Repeated IDNet Channel: up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel 24 VDC power for fiber optic transmitters 4090-9107, Class A (Style 7) Output Fiber Optic Transmitter 4009 IDNet NAC Extenders with optional internal IDNet Fiber Receivers Output NACs NOTE: Up to five (5) 4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one 4009 IDNet NAC Extender. 3 S4009-0002-6 8/2009 NACs NAC Input Selections. The 4009 IDNet NAG Extender can be selected to: Track input NAG operation or to provide a locally generated code, selectable per NAG input If selected for local coding, NAG outputs can be either Temporal Coded or 60 Beats/min March Time Coded, one code selection per extender (input NACs must be on continuous with Alarm) Additionally, NAG outputs can be selected to provide the Simplex strobe synchronization signal. This signal will synchronize the flashes of synchronized strobes but will be ignored by free-run strobes and audible devices. (Strobes are for operation by noncoded NACs.) NAG input to NAG output control can be selected for standard and optional NACs per the following table: Conventional NAC Output Operation Options Input A B C NAC 1 NACs 1 & 2, 5 & 6 NACs 1-4 NACs 1-8 NAC 2 NACs 3 & 4, 7 & 8 NACs 5-8 None SmartSync NAC Output Operation Input NAC Control Function NAC 1 Strobe Control All NAC outputs (1-8) NAC 2 Horn Control The TrueAlert Notification Appliance product line includes addressable and non-addressable operation. Non-addressable models are available with 2-wire SmartSync operation or conventional 4-wire operation. The following details apply to use with the 4009 IDNet NAG Extender: TrueAlert non-addressable models with SmartSync operation allow audible notification to be separately controlled over the same wire pair that controls visible notification (protected under U.S. Patent No. 6,281,789) 4009 IDNet NAG Extenders can be selected to provide SmartSync operation whether controlled by IDNet communications or conventional NACs IDNet control allows output NACs to be individually selected for conventional or SmartSync operation With NAG input control, all output NACs are selected for either conventional or SmartSync operation Refer to data sheet S4009-0003 for TrueAlert Addressable operation details, contact your local Simplex product supplier for further information on specific TrueAlert notification appliances C Hardwire Control NAC Connection One-Line Reference Diagram Up to eight (.3) output NACs total; hardwire control can be selected tc map NAC inputs to different combinations of NAC outpLts depending on system requirements NAC 1 input (see Note 1) Conventional NACs 6 ± '—,- - J With hardwire control, '-- " NAC outputs are all I Output conventional or all -: : NACs SmartSync operation Extender I Fire Alarm Control Panel / with Conventional NACs / SrnartSync operation — I Cwss A operation, either mode, requires NAC 2 input 4009-9808 Dual Class A Adapter (optional, see Note 1) To additional 4009 IDNet NAC Extenders (up to four (4), -----------] 4009 IDNet NAC Extenders per NAC); see Note 2 Notes: For separate audible and visible output NAC control, o SmartSync NAC output operation, two (2) input NACs are required. NAC 1 is "on-until-reset" and NAC 2 is "on-until-silenced To synchronize strobe flash outputs for up to four (4) 4309 DNet NAC Extenders, use the synchronized strobe output from a Synchronized Flash Module (4905-9914 fcr Class B operation, 4905-9922 for Class A operation) or, if available, from a NAC selected to provide synchronized strobe flash output. NOTE: DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 fo additional information and application guidance S4009-0002-6 8/2009 120 VAC Input (4009-9201) 3A@ 102-132 VAC, 60 Hz Input Ratings 240 VAC Input (4009-9301) Hardwire Control from External NACs, Input Requirements 1.5A @ 204-264 VAC, 50/60 Hz Conventional reverse polarity operation 5 mA maximum: 16 to 33 VDC Output Ratings Total Rating Standard NACs Optional NACs (requires 4009-9807) Special Application Appliances Regulated 24 DC Appliances Strobe Operation Auxiliary Output 1 8 A, Special Application appliances 6 A, Regulated 24 DC appliance power 2 A each, Special Application or Regulated 24 DC appliance power 1.5 A each, Special Application appliances 1 A each, Regulated 24 DC appliance power Simplex 4901, 4903, 4904, and 4906 Series non-addressable horns, strobes, and combination horn/strobes and speaker/strobes (contact your Simplex product representative for compatible appliances) Power for other UL listed appliances; use associated external synchronization modules where required Up to 33 strobes per NAC can be synchronized: output NACs configured for Simplex synchronized strobe operation are synchronized to each other 500 mA @ 24 VDC nominal Optional Modules Ratings IDNet Repeater Module (4009-9809) Input Power 70 mA @ 24 VDC, system supplied IDNet Input, One Address Maximum distance from IDNet source is 2500 ft (762 m) Repeated IDNet output for up to 100 devices (total IDNet devices not to exceed 250 per channel) IDNet Output Specifications Maximum distance to farthest device is 2500 ft (762 m) Total distance including "T-taps" is 10,000 ft (3048 m) Class A(Style 6) loop maximum distance is 2500 ft (762 m), no "T" taps Fiber Optic Receiver Modules Input Current 4009-9810, Class B (Style 4), 65 mA @ 24 VDC, system supplied 4009-9811, Class A(Style 7), 80 mA@ 24 VDC, system supplied IDNet Output Specifications Same as those for Repeater Module (see above) Fiber Optic Transmission Distance 3000 ft (914 m) maximum General (LED status indicators are listed on page 7, dimensions and mounting details are on page 6) Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range 10% to 90% RH from 32° F to 104° F (0° C to 40'-C) Wiring Connections* Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Fiber Optic Transmitter Specificatlo is Input Voltage 18.9-32 VDC from compatible listed fire alarm supply Input Current 4090-9105, Class B (Style 4), 30 mA @ 24 VDC 4090-9107, Class A(Style 7), 35 mA@ 24 VDC Fiber Optic Connections and cable requirements Multimode, graded index, 50/125pm, 62.5/125 pm, 100/40 pm, or 200 pm Type ST connectors 4090-9105, Class B (Style 4) operation, two fiber cables required 4090-9107, Class A (Style 6) operation, four fiber cables required Module Size (with mounting bracket) 6-13/16" W x 3-3/4" H x 1-1/8" D (173 mm x 95 mm x 29 mm) On-board Status Indicators Green LED flashing = transmit Red LED flashing = receive Separate red LED on 4090-9107 = Class A (Style 7) receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft (914 m) maximum Wiring Connections* Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Operating Humidity 10% to 90% RH from 32° to 104° F (0° to 40° C) Operating Temperature 32° F to 120° F (0° to 49° C) ° Metric wire equivalents: 18 AWG = 0.82 mm2; 12 AWG = 3.31 mm2 5 S4009-0002-6 8/2009 [I 4009 IDNet NAC Extender Mounting and Module Placement Information S 16-1/4(413 mm) 10-29/32 (277 mm) © E4009-9807 Optional Class A Additional Fouradapter modules J odule (shown with © ss A adapters) SystemModule D 1I lIDNet repeater II iber optic receives) © L. Cabinet depth 4-1/4 (108 mm) Door, 5/8" (16 mm) thick O\ (343 mm) © Exposed cabinet dimension for semi-flush mount 1" (25.4 mm), Knockouts for screw 1-3/8" (35 mm) with or nail mounting hole; semi-flush trim I © 01 UL © © © 12(305mm) Battery location, no conduit entry or wiring in I this area (12.7 Ah battery outline shown) 01 Semi-flush trim option Non-power limited wiring area (AC input) 1-3/16" wide (30 mm), 3/8" (9.5 mm) thick Wall surface reference for semi-flush mount NOTE: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574-181, specific module installation instructions, and to field wiring diagrams 842-068 before locating conduit entrance. 4009 IDNet NAC Extender Cabinet with Door Detail Optional red appliqué (4009-9805) 4009 IDNet NAC EXTENDER USimplex 1111111111 6 S4009-0002-6 8/2009 S S 4090-9105/9107 IDNet Fiber Optic Transmitter Mounting Information Surface mount box: —j °0 ° 0 0 0 Simplex model 2975-9217 (ordered separately) fl fi fi fi fi I Flush mount masonry box: use 6-gang box, RACO # 960, 2-1/2" deep (64 mm), or RACO #965, 3-1/2" (89 mm) deep, or equal (supplied by others) Flush mount ganged boxes: use 6-gang box, 1-1/2" (38 mm) minimum depth; six, RACO # 400 or equal, (supplied by others) Will jw __ _Iupiliu•I jIVA S S o o a o 0 0 o 0 0 0 0 IDNet fiber optic transmitter: 4090-9107, Shown, Class A (Style 7) output 4090-9105, Not shown, Class B (Style 4) output INSTALLATION NOTE: Fiber optic cable bend radius should be 2" (51 mm) minimum, or per Manufacturer's specification. Six-gang blank cover plate Mulberry Metal Products 97156 or equal (by others) E' F1 i] lr. i ir.iT I1I I (-.-I Power-up Self-Diagnostics. Upon power-up, the 4009 IDNet NAC Extender tests each module and performs earth fault diagnostics. Trouble conditions are communicated to the host control panel and are also displayed on diagnostic status LEDs in the 4009 IDNet NAC Extender. When connected via IDNet communications, detailed status information is available at the host. When controlled with conventional NAC inputs, common troubles are signaled by providing a polarized open circuit that disconnects the NAG wiring from its end-of-line resistor but still allows a reversed polarity alarm to be received. Door Mounted Reference Label. The 4009 IDNet NAG Extender has a detailed programming and diagnostic label inside the front door that provides a quick reference for both installation and checkout. LED Status Indicators are provided for the following: Each NAC (standard and optional) has a dedicated yellow LED that: - During supervision provides a slow flash to indicate a short circuit condition and a fast flash to indicate an open circuit - During an alarm, the LED follows the NAG output (on steady or flashing with coded output) Four, general status yellow LEDs provide nine separate indications listed in priority of urgency. As a trouble is eliminated, any remaining trouble(s) will then be indicated until the 4009 IDNet NAG Extender is returned to normal operation. AC power status is indicated by a green LED that is on when AG is normal. During low AG (brownout) conditions or with no AG, the LED is off. Additional power and battery status is indicated by the general status LEDs. S 7 S4009-0002-6 8/2009 4009 IDNet NAC Extender Current Chart S Panel Module Selection (shaded model numbers are optional modules) Model Description Supervisory Current Actual Supervisory Alarm Current Actual Alarm 4009-9201 120 VAC input Basic Panel 85 mA 85 mA d( 185 mA 85 mA 4009-9301 240 VAC input km 4009-9807 Additional Four Point NAC 40 mA + + NAC loads + NAC loads (add below) 4009-9808 Dual Class A Adapter (current - - - - included in basic panel value) 40099809* IDNet Repeater 70 mA + 70 mA + 80 mA 40099810' Fiber Optic Receiver, Class B 65 mA 65 mA 4009-9811* Fiber Optic Receiver, Class A 80 mA IDNet Devices, 0.7 mA each, maximum of 100 Total devices + Total devices Al + (see note 5) x 0.7 mA each x 0.7 mA each Auxiliary Power Output, calculate per total 500 mA + 500 mA 'A2' + device requirements (see note 5) maximum maximum ' Total Supervisory Current = (A) + (BI) Total 4009 IDNet NAC Extender Panel Alarm Current = * Only one of these three modules can be chosen for a single 4009 IDNet NAC Extender. t NOTE: IDNet Fiber Optic Transmitter current is supplied from the host fire alarm control panel. NAC Loads NAC Type NAC Circuit # NAC Alarm Current Circuit + Circuit 2 + Standard Panel NACS, 2 A maximum per NAC (see note 5) Circuit 3 + Circuit 4 + Circuit 5 + - Circuit 6 + Optional Four Point NAG Module, 1.5 A maximum per NAC (see note 5) Circuit 7 + Circuit 8 + Total NAC Loads Alarm Current = (132) + Total 4009 IDNet NAC Extender Panel Alarm Current (enter Bi from above) = Procedure: . Total Alarm Current = Calculate total panel supervisory current (A). Calculate total panel alarm current (Bi) [convert mA to A, example: 350 mA = 0.35 A]. Copy (Bi) into block (132). Calculate total NAC loads alarm current from notification appliance ratings (C). Add (C) + (132) to determine total alarm current (D). Total of IDNet Device Current (Al) + Auxiliary Power Output Current (A2) + NAC Loads Alarm Current (C) is 8 A maximum. Refer to Simplex battery selection document 900-012 for recommended battery size for specific standby requirements (i.e. 24 hours supervisory, 5 minutes of alarm). Internal cabinet space is provided for batteries up to 12.7 Ah. Tyco is a registered trademark of Tyco International Services GmbH and is used under license. Simpler, the Simplex logo. LifeAlarm. IDNet, WALKTEST, SmartSync, and TrueAlert ore trademarks of Tyco International Ltd. and its affiliates attcl ore used ttnder license. 0 .Simplex93 Tyco Safety Products Westminster• Westminster, MA 01441-0001 USA S4009-0002-6 8/2009 www.tycosafetyproducts-usa-wm.com © 2009 Tvco Safety Prodttcts Westntittster. All rights reserved. All specifications and otlter information shot cit tce,'e cturent as ofdocument ,'evtsion date attd ate stibject to change it ithout notice CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF TEE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:214 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 874-8542 FAX (978) 731-8881 DESIGN: Models* 4009-9001, 4009-9002, 4009-9101, 4009-910-1,009-9301, 4009- 9401 Notification Appliance Circuit (NAC) Power Extend a'listee's data sheet for detailed product description and operational considerations. Unit components: 565-594 Power Supply 565-569 Style Y Signal Card 565-358 Voice Controller Card 562-907 Amplifier Board 565-388 Style Z Signal Card 4009-9807 NAC Option Card 4009-9810 Fiber Receiver 4090-9105, *.9107 Fiber Transmitter 4009-9809 IDNet Repeater 4009-9808 Class A Adaptor 4009-9803, -9804 4 Circuit NAC Card 4905-9929 Isolator Module 4009-9806 Earth Detect Module S *40039803 Remote Microphone Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. The NAC must be fully supervised and must have the secondary power supply capable of operating the system for at least 24 hours (battery standby) in the normal condition and followed by not less than 5 minutes of alarm as required by code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power extender units for use with listee's separately listed fire alarm control units. *RevIRece 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 8, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ml- I Batten, Details (Cntiniid) Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Specification Summary Nominal Voltage Rating 12 V/battery Discharge Rating 20 Hour Rate Typical Chart/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F 1 (15.6°C to 32.2° C) These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. 0 5 Simplex Fire Alarm Control Panel Accessories Cabinet Mounted System Batteries; 2081 Series, Sealed Lead-Acid; 6.2 Ah to 50 Ah Rechargeable, sealed lead-acid design: Lead-calcium grid structure Immobilized electrolyte in absorbent separator High reliability dual seal construction Low maintenance, no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size For applications requiring 110 Ah batteries: Refer to data sheet S4081-0002 for 4100U systems Refer to data sheet S2081-0012 for 4100/4120 series system S I I4-1 1t!1 Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. I:'I.IT1Vill Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal S voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) S2081-0006-16 9/2004 Inner cover Absorbent sei used to imrr e1e Lead-calciur C Typical Construction Details Actual appearance will vary with battery size. C nnlnd in, far rr,,,inr Potting material, black for negative, red for positive (polarity is also clearly :Tiac1ed with + End -) Pressure relief valve Semi-pErmeable mem br r e separator S Cell case (high impact polystyrene) S208-3006-16 9200i Battery Specifications Battery Model Capacity @20 Hour Width* Depth* Height with Approximate Discharge Rate Terminals Weight* 2081-9272 6.2 Ah 6-1/8" (156 mm) 2-5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah 6" (153 mm) 4-1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6" (153 mm) 4" (102 mm) 4" (102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) 5(127mm) 7" (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8(86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 ("square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9-1/2" (241 mm) 1 5-1/2" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Simplex Control Panel Model Series (see legend and notes below) Battery Capacity ______ 4003 4004 4004R 4005 4006& 4009 4 1 00 4100U 4100&4120 4020 Model 4008 (all models) (2 or 3 bay) (2,4 or 6-Unit) (2, 4 or 6-Unit) 6.2Ah 1 ,( / I / 1 1 1 / / 10 Ah ,( 1 1 1 / 2081-9288 12.7 Ah I / / 1 2081-9275 18 Ah I Note 3 1 Ext Ext Note 2 2081-9287 25 Ah Note 3 Ext / / .1 Ext 2081-9271 (rectangular) 33 Ah Note 3 Ext Note 3 1 Ext Note 4 2081-9276 square 33 Ah Note 3 Ext Note 3 / 1 Ext 2081-9296 50 Ah Note 3 Note 3 1 Ext Ext I = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 Shaded areas = Not applicable NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Some control panel models are listed for battery replacement reference only. S2081-0006-16 9/2004 [Extnal Battery Cabinet Compatibility Reference Externally Mounted Battery Battery Cabinets without Chargers Battery Cabinets with Chargers (connects to charger in panel) Model Capacity 4°1 ____________ 20819301** 20819303** Series 2081-9270' 2081-9281 2081-9282 4009-9801 4009-9802 2081-9275 18 Ah If If 1 1 2081-9287 25 Ah 2081-9271 1( / (rectangular) 33 Ah 20819276 / square) 2081-9296 50 Ah * Batteries smaller than those listed are normally mounted in the product cabinet. ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. 1= Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specification Reference Model Description Color Dimensions 2081-9281 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 2081-9270* External battery cabinet without charger Red 26-1/2" W 12" H 12" D (673 mm x 305 mm x 305 mm) 2081-9301 External battery cabinet with charger 2081-9302* External battery cabinet without charger and with meters for voltage and current 20819303 External battery cabinet with charger and with meters for voltage and current 4009-9801 For up to 18 Ah External battery cabinet without charger, 16-1/4" W x 13-1/2" H x 4-1/8" D batteries with solid door and battery harness, for close-nippled mounting to fire alarm control Beige (413 mm x 343 mm x 105 mm) For up to 33 Ah 25-3/4" W 20-3/4" H x 4-1/8" D 4009-9802 batteries panel cabinet (654 mm x 527 mm x 105 mm) 4081 For up to 50 Ah Companion cabinet with charger for the Beige or 22-1/2" W x16-3/4" H x 8-3/8" D Series** batteries 4010 and 4004R fire alarm control panel Red (572 mm x 425 mm x 213 mm) * Refer to Simplex data sheet S2081-0002 for additional information. ** Refer to Simplex data sheet S4081-0001 for additional information. Tt'co, Simplex, and the Simplex logo are trademarks of Tt'co International Services AG or its a//I/ia/es in the U.S. and/or other countries. BSirriplex Tyco Safety Products Westminster• Westminster, MA 0144 1-0001 USA S20981-0006-16 9/2004 www.tycosafetyproducts-usa-wm.com © 2004 Ti'co Sa/ètv Products Wesuninster All rights reserved. All specifications attcl other information sh,ote,t were c//tee/It as of document,etision date and are subject to c//a//ge tilt/tout /70/ice. S • 93,,Simplex Multi-Application Peripherals UL, ULC Listed; FM, CSFM, MAPNET Il® or IDNetTM Communicating Devices and MEA (NYC) Approved* Addressable Manual Stations Individually addressable manual fire alarm - stations with: I ----- Power and data supplied via MAPNET II or IDNet addressable communicationscommunications using a single wire PULL Lj pair** I Operation that complies with ADA requirements Pull lever that protrudes when alarmed = Break rod supplied (use is optional) Models are available with single or double action (breakglass or push) operation 4099-9001 Addressable Manual Station UL listed to Standard 38 (front and side view) Compatible with Simplex kl1j I Model Series 4010/4100/4120/4020 fire alarm control panels equipped with either IDNet or IOJLL DOWN __________ MAPNET II communications - ERAT Model Series 2120 communicating device OP ED ONLY transponders (CDTs) equipped with MAPNET H - communications L. - Compact, sealed construction: 4099-9002 4099-9003 With 2098-9828 NEMA 2 enclosure rating for minimal dust Breakglass Push Institutional infiltration Cover kit Allows mounting in standard electrical boxes Screw terminals for wiring connections Activation of the Simplex 4099-9001 single manual station requires a firm downward pull to activate the Tamper resistant reset key lock (keyed same as alarm switch. Completing the action breaks an internal Simplex fire alarm cabinets) plastic break-rod (visible below the pull lever, use is Multiple mounting options: optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull Surface or semi-flush with standard boxes or requirements needed for easy activation. The pull lever matching Simplex boxes latches into the alarm position and remains extended out Flush mount adapter kit of the housing to provide a visible indication. Adapters are available for retrofitting to Double Action Stations (Breakglass) require the commonly available existing boxes operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever IiI3-i.1llt71 then operates as a single action station. The Simplex model 4099-9001 addressable station Double Action Stations (Push Type) require that a combines the familiar Simplex manual station housing spring loaded interference plate (marked PUSH) be with a compact communication module that is easily pushed back to access the pull lever of the single action installed to satisfy demanding applications. Its integral station. individual addressable module (lAM) constantly monitors Station reset requires the use of a key to reset the status and communicates changes to the connected control manual station lever and deactivate the alarm switch. (If panel via MAPNET Il or IDNet communications wiring, the break-rod is used, it must be replaced.) This product has been approved by the California State Fire Marshal (CSFM) pursuant to Station testing is performed by physical activation of Section 13144.1 of the California Health and Safety Code. See CSFM Listing the pull lever. Electrical testing can be also performed by W 7150-0026:224 for allowable values and/or conditions concerning material presented in this unlocking the station housing to activate the alarm switch. document. it is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35.93E. Additional listings may be applicable, contact Simplex for the latest status. MAPNET II and IDNet addressable communications designs are protected by U.S. Patent No. 4,796,025. © 2000 Simplex Time Recorder Co. All rights reserved. S4099-0001-5 8/00 Addressable Manual Station Product Selection Addressable Manual Stations Description 4099-9001 )__ Single action Double action, Breakglass operation 4099-9003 Double action, Push operation Accessories Addressable manual station, red housing with white letters and white pull lever S Model 2975-9178 Description Surface mount steel box, red Reference Refer to page 3 for dimensions 2975-9022 Cast aluminum surface mount box, red 2099-9813 Semi-flush trim plate for double gang switch box, red Typically for retrofit, refer to page 4 2099-9814 Surface trim plate for Wiremold box V5744-2, red 2099-9819 Flush mount adapter kit, black Refer to page 4f0r details 2099-9820 Flush mount adapter kit, beige 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 I Specifications Power and Communications _&WAPNET III per station, up to 2500 ft (762 m) from fire alarm control pa , , 4ddress 48 m) total wiring distance (including T-Taps) Address Means Dipswitch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F(0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan® polycarbonate Pull Lever Color White with red raised lettering Housing Dimensions 5" H x 33/4W x 1" D (127 mm x 95 mm x 25 mm) Addressable Manual Station Semi-Flush Mounting Single Gang Box Mount Single gang box, 2 1/2" deep (64 mm), RACO #500 or equal (supplied by others) o C U0 [FIRJ PULL DOWN HJ 4" Square Box Mount 4" (102 mm) square box, 2 1/8" (54 mm) minimum depth, RACO #231 or equal (supplied by others) / (Th Th jTh Z I ° 0 / Mount flush or with 1/16" (2 mm) ____ J 0 maximum extension 4" Square box 0 DO NOT RECESS with cover plate o - ( L (Jj -- o 'V Station side view Single gang cover plate, 3/4" --------- (19 mm) extension, RACO #773 - , or equal (supplied by others) Single gang Wall surface box outline Semi-Flush Mount Side View S Simplex Time Recorder Co. 2 34099-0001-5 8/00 Fiek (shown for ref( Address setting under resealable label (accessible with cover open) Station cover hinges open for installation access Simplex Time Recorder Co. 3 11/4" Addressable Manual Stations Surface Mounting S Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 2975-9178 Box 5 3/16" H x 4" W x 2 3/16" D (132 mm x 102 mm x 56 mm) (ordered separately) \ Knockouts located top and bottom 2975-9022 Cast Box 5" H x 37/SW x 2 3/16" D (127 mm x 98 mm x 56 mm) (ordered separately) FIRE_ (V }[ALAR PULL DOWN 1 Access for 3/4" threaded c' I II II II II I I conduit located lop and bottom (127 mm) ! 'S Simplex,, —L — / 1 " (25.4 mm) 33/4(95mm) 4099 Series Addressable Manual Station S Surface Mount Side View with Internal Detail [Application Reference Refer to NFPA 72, the National Fire Alarm Code (reference section 5-8), and all applicable local codes for nplex 2975-9178 box complete requirements for manual own for reference) stations. The following summarizes the basic requirements. Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible. /8 im) Mounting shall be with the operable part not less than 3 1/2 ft (1.1 m) and not more than 4 1/2 ft (1.37 m) above floor level. At least one station shall be Switch wiring provided on each floor. Additional (prewired) stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. When manual station coverage appears limited in any way, additional stations should be installed. S4099-0001-5 8/00 For retrofit and new installations, additional compatible mounting boxes and the required adapter plates are shown in the illustration to the right. 2099-9814 Surface trim for Wiremold box 5 1/8" H x 5" W (130 mm x 127 mm) Please note that these addressable manual stations will also install onto single gang Wiremoldw box model V5747 but will overlap the box. Wiremold V5747 dimensions are: 4 5/8" H x 27/8" W x 3/8" D (117 mm x 73 mm x 35 mm). 4099-9001 IDNet addressable station 2099-9813 Semi-flush trim for 2 gang switch box, 6" H x 4 1/2 W (152 mm x 114 mm) Flush mount adapter kit 2099-9819, Black 2099-9820, Beige 8 (203 mm) 6" (152 mm) Cutout must be a m of 6" H by 5W (..mmby127mm) I I! I \ / Wall 43/4" (121 mm) surface 63/4" (171 mm) Addressable Manual Station, Additional Mounting Information . S Wiremold receptacle box model V5744-2 (supplied by others) Two gang switch box, each 3" H x 2" W x 2 3/4" 0 (76 mm x 51 mm x 70 mm) (supplied by others) E c? Addressable Manual Station, Flush Mounting Information HBox must be recessed into wall 1" to 11/8" (25.4 mm to 29 mm) 0 0 4 11/16" (119 mm) square box, 2 1/8" (54 mm) minimum depth (by others) Front View Side View Simpler, the Simplex logo. MAPNETII. and IDNet are either trademarks or registered trademarks of Simple.r Time Recorder Co. in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association ('NFPA). Levan is a trademark of the General Electric Co. Wiremold is a trademark of the Wiremold Company. S4099-0001-5 8/00 Westminster, Massachusetts 01441-0001 USA SirnpIex visit us on the world wide web at www.simpIexnef.com All specifications and other information shown were current as of printing and are subject to change without notice. S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0026:224 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Model 4099-9001, -9 02, -9003, -9010, *.901oTSp *901oTTp -9011, -9012, *9012Tsp *9o12T H' 31C non-coded addressable manual pull stations. Models 4099-9001 and -9010 are single action stations. Models 4099-9002 and -9011 are breakglass stations. Models 4099-9003 and -9012 includes a push bar which must be punched in before being able to grab and pull down the actuating handle. Model 4099-9031 C is a double action station. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. Models are intended for use with listee's Models 4010, 4100,4100U and 4020 control units (CSFM Listing Nos. 7170-0026:226, 7165-0026:160 or 7170-0026:187, 7170-0026:250 or 7165- 0026:251 and 7165-0026:178). Model 4099-9013C is intended for use with Model 4010 control unit only. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rev. 09-25-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 8, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division [I: 5®Simplex TrueA/arm® Analog Sensing UL, ULC Listed; FM, CSFM, TrueAlarm Analog Sensors - Photoelectric, and NYC, MEA Approved* Ionization, and Heat; Compatible Bases and Accessories S * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safely Code. See CSFM Listings 7272-0026:218, 7271.0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Refer 10 page 4 for ULC listing status. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. I 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement that is digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate relérence for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the.control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. TrueAlarm analog sensors and MAPHET II and IDNet communications are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; 5,552,765; 5,552,763; 4,796,025; DES. 377,460, TrueAlarm® analog sensing provides digital transmission of analog sensor values via MAPNET Il® or lDNetTM, two-wire communications** Fire alarm control panel provides: Individual sensitivity selection for each sensor Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allowing accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check that verifies sensor integrity Automatic environmental compensation Display of sensitivity directly in percent per foot Multi-stage alarm operation Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors: Seven levels of sensitivity from 0.2% to 3.7% Heat sensors: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Ionization smoke sensors*: Three levels of sensitivity; 0.5%, 0.9% and 1.3% For use with Simplex®: 4010, 4020, 4100, and 4120 Series control panels Universal Transponders and 2120 TrueAlarm CDTs equipped for MAPNET 11 operation Magnetic test feature Functional and architecturally styled chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Optional accessories include remote LED alarm indicator and output relays UL listed to Standard 268 S4098-0019-8 12/01 TrueAiarm Sensor Bases and Accessories Base mounted address selection: Address remains with its programmed location Accessible from front (dipswitch under sensor): Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design Magnetically operated functional test Mounts on standard outlet box Fi.i i-i 4098-9792, Standard sensor base 4098-9789, Sensor base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (unsupervised) 4098-9791, Sensor base with supervised relay diver output (not compatible with 2120 CDT): Relay operation is programmable and can be manually operated from control panel Use with remote mount 2098-9737 relay Also includes wired connections for remote LE alarm indicator or 4098-9822 relay 0XITTOM"WOMMO M, 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of3 A @ 28 VDC; non-power limited rating of A @ 120 VAC (requires external 24 VDC coil power) 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting tJ 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box ALARM (shown in illustration to right) 0 g Simplex istrintic TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionization, or heat sensors. Eacl sensor's output is digitized and transmitted to the system lire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, dilTernt sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentiona sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for buiLling protection at that location. h' r;irrniiiti Electrical Box Requirements: (boxes are by others) relay: 4" octagonal 0r4" square, 1-1/2 deep; single gang, 2" deep With i61aL: 4" octagonal or 4" square, 1-1/2' deep. with 1-1/2' extension ring 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference-... ii k Eo I t 1-1/2" (36 mm) minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum reces ------------------------------------------------- 2098-9737 Relay (mounts in 4098-9822 Relay (mcunts base electrical box or remotely) in base electrical boxy Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 cubic inches) (64 mm X 38 mm X 25.4 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. -------------------------------------------------- 6-3/8" (162 mm) t 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) and 4" square flush box 4-7/8" (124 mm) 15/16" (24 mm) TrueAlarm Bases 4098-9789, -9791, & -9792 S S S S4098-0019-6 12/01 TrueAlarm Sensors is lit' l4- Sealed against rear air flow entry Interchangeable mounting EMl/RFl shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Listed to UL Standard 521 for 60 ft (18.3 m) spacing for 1350 F (57.2° C) alarm, and 40 ft (12.2 m) spacing for 1550 F (68° C) alarm Smoke Sensors: • Photoelectric or ionization technology sensing • 360° smoke entry for optimum response 109R-7 Hat nsr TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.10 C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at . 135° F (57.2° C) or 155° F (68° Q. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. (Refer to specific panels for availability.) 4-7/8' (124 mm) T 0LED status indicator) 2-3/8 (60 mm) TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. A built-in screen keeps insects from entering the smoke chamber. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 4-7/8(124mnn) T LED status indicator 2-1/8" (54 mm) liii II I III I I 4098-9714 Photoelectric Sensor with Base is ri .J i t-i. i TrueAlarm Ionization sensors use a single radioactive source with an outer sampling ionization chamber and an inner reference ionization chamber to provide stable operation under fluctuations in environmental conditions such as temperature and humidity. Smoke and invisible combustion gases can freely penetrate the outer chamber. With both chambers ionized by a small radioactive source [Am 241 (Arnericium)i, a very small current flows in the circuit. The presence of particles of combustion will cause a change in the voltage ratio between chambers. This difference is measured by the electronics in the sensor base and digitally transmitted back to the control panel for processing. Three levels of sensitivity are available for each ionization sensor: 0.5, 0.9, and 1.3% per foot of smoke obscuration. I. 4-7/8" (124 mm) J ULED status indicator 2-1/8" (54 mm) 4098-9733 Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life . Safety is a factor, the use of smoke detection is highly recommended. 4098-9717 Ionization Sensor with Base V±1 iii r,i i r.i ill :4'3 fii ir..i Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide. For detailed application information, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). S4098-0019-8 12/01 I ITt F1 v1lTflflT1 t!11 flil TrueAlarm Sensor Bases e odel I Description I Compatibility I Mounting Requirements I 4" octagonal or 4" square box,1-1/2" mm. depth, Sensor Base, no options Sensors 4098-9714, -9733, & -9717 I with 3" 0-ring; or single gang box, 2" min. depth Sensor Base with connections for 4098-9789 (C) Remote LED Alarm Indicator or Unsupervised Relay Sensor Base with connections for 4098-9791 (C' Supervised Remote Relay and connections for Remote Alarm Indicator or Unsupervised Relay TrueAlarm Sensors Description 4098=9714 )~ Photoelectric Smoke Sensor 4098-9717 (C) Ionization Smoke Sensor 4098-9733 (C) Heat Sensor TrueAlarm Sensor/Base Accessories Model Descriotion Sensors 4098-9714, -9733, & -9717 2098-9808 remote LED alarm indicator or 4098-9822 relay Sensors 4098-9714, -9733, & -9717 2098-9737 remote relay (supervised) 2098-9808 remote alarm indicator or 4098-9822 relay (unsupervised) Compatibility Bases 4098-9792, 4098-9789 and 4098-9791 Comoatibilitv 4" octagonal or 4" square box with 3" 0-ring, Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. Mounting Requirements Refer to base requirements Mountina Reauirements Remote Mounting requires 4" octagonal or 2098-9737 Supervised Relay, mounts remote For use with 4098-9791 base 4" square box, 1-1/2" minimum depth or in base electrical box Base Mounting requires 4" octagonal box, 2-1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator Single gang box, 1-1/2" minimum depth on single gang stainless steel plate Bases 4098-9789 and 4098-9791 Relay, tracks base LED status 4" octagonal box, 2-1/8" deep with 1-1/2" 4098-9822 (C) (unsupervised, mounts only in base extension ring electrical box) Required for surface or semi-flush 4098-9832 Adapter Plate Bases 4098-9792, -9789, & -9791 mounted 4" square box without 3" 0-ring, am for surface mounted 4" octagonal box F(eter to puolication 4U95 Detectors, 75ens0rs, and bases Application Manual (0l4-1U/) Tor aacliiionai intormation. ULC listen monel numbers are designated by (C) and require a "C" suffix such as 4098-9794C. TU ff. T [.] .i General Operating Specifications and Sensor Supervisory Power %Communications MAPNET II or IDNet, uto-select, 24-40 VDC w/data, 400 iA typical, arss per ba Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG UL Listed Temperature Range 32° to 100° F (0° to 38° C) Operating with 4098-9717 or 4098 -9733 Temperature Range with 4098-9714 32° to 122° F (0° to 50° C) 150 to 122° F (-90 to 50° C) Humidity Range 10 to 95% RH Smoke Sensor 4098-9714, Photoelectric Sensor Ambient Ratings 4098-9717, Ionization Sensor Air velocity is 0-2000 ft/mm (0-610 rn/mm) Air velocity is 0-100 ft/mm (0-30 rn/mm); Altitude is up to 8000 ft (2.4 km) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 tA, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply lyco Simplex, the Situp/es 1(t//o, 7rueA/arut, IviAPN/t7 Ii, and IDNet are trademarks ofi)'co International Services AG or its a//ilia/es in the U.S. and or outer countries. N/PA 72 is a registered trademark of the National Fire Protection Association (N/PA). 93Si1T1pIex Westminster, Massachusetts 01441-0001 USA www.simplexnet.com S4098-0019-8 12/01 ( 200/ Simplex Tittte i/reorder Co. DBA //,,'PG-(IS (a /yco company). All rights reserved. A/I specifications and other inJ)trmatton shott'n were current as 0/document retoston c/ale anti are subject to change ti/hoot notice. S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:217 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: 1Tt4098-9789, -9789E, 9789TSP, -9789TTP, -9791, -9791E, -9791T5P, 9791TTP, 9792)-9792E, -9792T5P, 9792TTP, -9793, -9793E, -9793TSP, -9793TTP, -9794, - 7TSP, -9794TTP, -9795, -9795TSP, -9795TTP, -9796, -9796T5P, -9796TTP; *G5A4098 9792, *..9793 *9795 and *9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Bases are intended for use with the following units: Models 4098-9714 and *G5A40989714 series photoelectric smoke detector (CSFM Listing No. 7272-0026:218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:231); and Models 4098-9733 and *GsA40989733 heat detector (CSFM Listing No. 7270-0026:216). Models 4098-9795, -9795TSP, -9795TTP, -9796, - 9796TSP, -9796TTP; *GSA4098..9795 and *9796 are only intended for use with Models 4098-9754 or *GsA4098..9754 photoelectric smoke detector *(CSFM Listing No.7272- 0026:218). Refer to listee's printed data sheet for additional detailed product description and operational considerations. S INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Models 4098-9794, -9794TSP, -9794TTP, -9795, -97951SP, -9795TTP; and *GSA4098..9795 employ a sounder, which is also suitable for use as a fire alarm audible signaling device. These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. *Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: MAY 8, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE V LISTING No. 7272-0026:218 Page 1 of 1 CATEGORY Photoelectric Smoke Detector LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Model ;9 ;8- %40 -9714TTP, -9754 -9754T5P, -9754TTP; *G5A40989714 and type smoke detectors. Units are intenied for use with smoke detector bases Models 4098-9789 9789TSP, -9789TTP, -9791, -979115P, -9791TTP, -9792, -9792TSP, 9792TTP, -9793, 9793T5P, -9793TTP, -9794, -794TSP, -9794TTP; *GSA40989792 and *9793 (CSFM Listing No. 7300-J026:217). Models 4098-9714, -9714T5P and -9714TTP are listed for use with Models 4098-9750, -9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:220) and Models 4098-9755, -9755TSP and -9755TTP duct detector units (CSFM Listng No. 3240-0026:241). Models 4098-9754, -9754T5P, -9754TTP; *GsA4098..9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemen:al device to the smoke detector and is not intended for use in lieu of required heat detectos. Refer to listee's printed data sheet for additional detailed product descriptio,i and operational considerations. 0 INSTALLATION: In accordance with listee's printed installation instrucLons, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed Models 4100, 4010, 4020, 4120 and *4008 series fire alarm control units. Refer to lis:ee's Installation Instruction Manual for details. *Re., O -03-2005 Tis listing is based upon technical data submitted by the applicant. CSFM Fire Eng:neerirg staff las reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not ai endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requiements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued MAY 8, 2009 Listing Expires Jine 30, 2010 01 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division S B®Simplex TrueAlarm® Analog Sensing UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control S I k' I Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNetTM or MAPNET 11(5, 2-wire communicationst Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNet/MAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026,241 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simples product supplier for the latest status. Listings and approvals coder Simples Time Recorder Co. are the property of Tyco Safety Products Westminster. —I' oua! Duct Sensor Housing, Front and Bottom View m 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station irnrrrri Operation. Simplex"' compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. I ITTT F1iiiti iIi.] jy;1 Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. ** Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarm sensors and IDNet and MAPNET II communications are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400014; 5543,777; 5,710541; 0383407; D388352; 0392,573; 4,796,025. S4098-0030-5 3/2007 I7T! m'in .i xi iYDIThW11liJ I J T1 f t-flT F11JITij Control Panel Selection. Peak activity per sensor is Typically duct sensor applications require less sensitive stored to assist in evaluating specific locations. The alarm settings (such as 2.5% per foot obscuration) due to the set point for each sensor is determined at the control ducts being a relative dirty environment. However, the panel, selectable as the individual application requires. standard seven levels of TrueAlarm sensor sensitivity are Sensor Status LED. Each sensor housing's red status available for each individual sensor, ranging from 0.2% to LED (located on the electrical interface board) pulses to 3.7% per foot of smoke obscuration. Sensitivity is s indicate communications with the panel. If the control elected and monitored at the fire alarm control panel. panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's • Individual smoke sensitivity selection status LED will be turned on steadily. During a system • Sensitivity monitoring that satisfies NFPA 72 alarm, the control panel will control the LEDs such that sensitivity testing requirements an LED indicating a trouble will return to pulsing to help • Peak value logging allows accurate analysis for identify any alarmed sensors. (Remote Status/Alarm sensitivity selection LEDs track the operation of the sensor housing LED.) Automatic, once per minute individual sensor . calibration check verifies sensor integrity TrueAlarm photoelectric sensors use a stable, pulsed • Automatic environmental compensation infrared LED light source and a silicon photodiode • Smoke sensitivity is displayed in percent per foot receiver to provide consistent and accurate low power • Ability to display and print detailed sensor smoke sensing. information in plain English language Relays of model 4098-9756 are under panel control for ON, OFF, or override I iJT mr.] &.T1 !TI4 TTi Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description Compatibility Basic Duct Sensor Housing; operating power is supplied by Simplex fire alarm control panel models 4010, 4020, 4100, 4100U, and 4120. Also 2120 CDT if 4098-9755 either lDNet or MAPNET II communications (no relay output) configured for MAPNET II, TrueAlarm operation 4098-9756 Duct Sensor Housing with supervised multiple relay output, fire 4081-9008 Same as above except relay operation is not compatible with 2120 CDT; requires separate 24 VDC alarm power and end-of-line resistor harness; includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator Use single gang box, Test Station with keyswitch and red LED status indicator 4098-9755 3"Hx2"Wx2" D 2098-9806 4098-9756 (76 mm x 51 mm x 51 mm) (turning switch to TEST" initiates alarm for system testing) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C (7 A © 120 VAC); refer to pages 3 and 4 4098-9756 only; Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; (1 m) of device being connect up to 15 wiring is 18 AWG (0.82 mm2 ) color coded wire lEads controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 kQ, 1/2 W; (ref. 733-894); 4098-9756 At last relay location required to supervise remote relay coil connectioi * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. rr Pill i r i- . -ri ri i I1rrri Arn -i rTI.T1 Overall Duct Width (305 mm) Tube Required 2098-9796 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2" (51 mm) longer than duct width 46" to 71" (11168 mm to 1803 mm) 2098-9798 2(51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 2" (51 mm) longer than duct width .2 54098-0030-5 3/2007 S 11111ffmi.i. i1f. : rirn ni1 .rii I111471.1-11 NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. 11-3/8" (289 mm) aust tube access hole ] conduit b others fx) 4098 I oke sensor, mount d '7 ... . in sr f h ( i dl 7-si . Metal plate with dual holes for 3/4" (19 mm) conduit, plug supplied for unused hole 6-3/4" (171 mm) \ I (ellow LED, relay control trouble Sampling tube J indicator (4098-9756 only) access hole U nF ed sensor - - tatus LED of duct Wiring terminals hffi (hiiti\ Captive fasteninq screws (4)l If Maqnetic It st area Mount as shown (preferred) or cover with electronics area located to (sketed sensor area) the LEFT or UP ONLY 13/16" __________ askets (supplied)J -T (21 mm) Test ports (2) provided ing tube ordered Exhaust tube (suPPlied) all for measuring a, rf inflow ] and for aerosol iniection separately per duct width End View with Duct and Tubes Duct housing Round duct outline (minimum diameter) 8" Square duct outline1 Exhaust tubes' :-1 (minimum width) j Sampling tube, keyed for proper hole alignment with holes facing into airflow (template is provided for proper tube installation) 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 7W1 3/16" (38 mm) 1-3/16" (30 mm) 3 S4098-0030-5 3/2007 IDuct Sensor Location Reference Exhaust Sensor Damper OK Exhaust -[IIJ I .,Retrrn Air Do not locate sensor here Return air damper Fresh Supply - air Air ( Filter Do not locate ens r bank OK sensorhere Bend or other obstruction Return air" inlet ff6DuccA 6 Duct m / widths ilimum widths minimum Preferred Duct Sensor Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A. Standard for the Installation of Air Conditio'nng arid Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. r Specifications General Mechanical and Environmental Air Velocity Range (linear ft/min) 330 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0 2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 1000 F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (Cl' C to 50° C) Storage Temperature Range 0' F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, ion-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color B act- base with cear cover Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 irA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 rrA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 2.50 ft (76 m) maximum Addressable Operation Data Communications IDNe: or MAPNE II communications, auto-select, one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage nominal) Standby Current 1000, 3 mA @ 24 VDC' Alarm Current (one relay activated) 15 mA @24 VDCd 15 mA for each additional remote 4098-9843 relay relay only, quantity of 15 maximum; distance of 500 ft Supervised Remote Relay Control Output (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 ko, 1/2W end-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current 15 mA @24 VDC, up to 15 maximum per relay control output 7 A a 0.35 PF @ 28 VDC & 120 VAC Relay Contacts 250 iA Q 5 VDC Location Distance 500 ft (152 m) maximum to relay coils; relays must be within 3 ft (1 m) of deice being controlled per NFPA 72 Tyco. Simplex. he Simplex logo. TrueAlarm. ID Net. and MAPNETI/ are t,aue,narks of?`yco international Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Ph-c A lot-rn Code are registered trademarks of the Noaonal Fire Prctetion Association (NFPA). 93 - mplex Tyco Safety Products Westminster Westminster, MA • 01441-0001 USA S4098-0030- 3/2007 www.zyccsafetyproduc,s-usa-wm.com © 2007 Tyco So,'htv Products Wesnninster. All rig/us reserved. All specificatic-is are/other infot-matirn shot,,, it ere curt-vt,t as of document i-em/sian date and are subject to change ri,Iot,, notue. S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:241 Page 1 of 1 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441*0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4098-9755, *4098.97551sp *4og8g755TT99756*o989756TsP *40989756TTp 4098-9685, 4098-9686, 4098-9687 ai 8 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. 0 MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 8, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division B Simplex UL, ULC Listed; FM, CSFM, and MEA (NYC) Approved* Install the model 4098-9714 TrueAlarm analog photoelectric sensor directly inside air ducts** Accommodates duct airflow from 35 to 600 ft/mm (II to 183 mlmin), providing HVAC duct smoke sensing where sampling tube designs are not appropriate For applications with controlled dust and humidity Standard models are for rectangular ducts from 6" (152 mm) square to 36" (914 mm) square Optional adapters allow use with round ducts of 6" or 8" (203 mm) in diameter TrueAlarm analog communications can be either MAPNET 11w or lDNetTM forrnatt Model 4098-9714 sensor is required and ordered separately Red alarm LED indicator in housing: Visible through transparent housing cover Pulsing indicates power-on, steady on indicates alarm or trouble as indicated at the fire alarm control panel S Model 4098-9750 provides two-wire operation (no relay output) Model 4098-9751 provides a local relay: Relay operation is programmable from fire alarm control panel and is rated: I A @ 28 VDC, power limited; or 1/2 A @ 120 VAC, non-power limited 24 VDC power is supplied by fire alarm system (4-wire operation) Options: Adapters for 6" or 8" round ducts Remote Test Station (2098-9806) Remote LED Alarm Indicator (2098-9808) UL listed to Standard 268A * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026:220 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. ULC listed models are designated with a C" suffix such as 4098-9750C. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. ** Please note that smoke detection in air ducts is intended to notify of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. S t TrueAlarm analog sensors are protected by one or more of the following U.S. Patents: 5,155,468; 5.173,683; 6,400,014; 5,543,777; 5,710,541; 0383,407; D388,352; D392,573. MAPNET II and IDNel addressable communications designs are protected by U.S. Palest No. 4,796,025. TrueA!arm® Analog Sensing In-Duct Mounting of the 4098-9714 TrueAlarm Photoelectric Smoke Sensor In-Duct Housing with 4098-9714 Sensor and Optional 8" Round Duct Adapter pscrintir HVAC air ducts in buildings supply fresh air and exhaust stale air. Depending on the overall fire detection requirements, smoke detection may be required in the air ducts. For applications where sampling tube type duct detection is not appropriate due to low air velocity or small duct size, Simplexw model 4098-9750 and 4098-9751 housings can be used to install the Simplex model 4098-9714 TrueAlarm analog sensor directly in the duct. (Refer to data sheet S4098-0030 for smoke sensor housings with sampling tubes.) Application. These housings mount a spot-type smoke sensor directly into the duct airflow. Proper application requires controlled dust and humidity. Please note that in the event of loss of duct airflow, then 4098-9714 sensor will sense smoke IF the smoke reaches the sensor. However, with no duct airflow, smoke may not reach the sensor depending on the location of the smoke source relative to the sensor. TrueAlarm Operation. Placing a 4098-9714 sensor in an air duct provides the high reliability performance of TrueAlarm analog sensing featuring: programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation. These housings digitally communicate their analog sensor information to the fire alarm control panel using either MAPNET ll or lDNetTM two-wire communications. Relay Model. Model 4098-9751 provides a relay that can be programmed to track the local sensor's operation or can be independently controlled by the fire alarm control panel to perform fire response actions such as fan shutdown and damper control. S4098-0021-5 11/02 ALARM 0 S Simplex 2098-9808 S4098-0021-5 11/02 4sIi:ei;III.1 2 ALARM 0 I Preferred In-Duct Sensor Locations: Locations To Avoid: 1. A minimum of six duct widths downstream frcm Areas of high humidity such as near humidifiers. bends or inlets to avoid air turbulence. Areas with high levels of dirt and dust. 2. On the downstream side of filters to detect fires in the 3. Where dampers closed for comfort control would Filters. interfere with airflow. 3. In return ducts, ahead of mixing areas. 4. Next to Outside air inlets (unless the intent is to 4. Upstream of air humidifier and cooling coils. monitor smoke entry from that area). 5. With accessibility for test and service. 5. In return air damper branch ducts and mixing areas where airflow may be restricted. 6. For additional information, refer to NFPA 90A, Standard for the Installation ofAir Conditioning 2nd Ventilating Systems. In-Duct Sensor Location Reference - - Exhaust Sensor Damper OK ' Exhaust -LIII1 Return Air Do not loca:e sensor here Return air damper Fresh I - I Supply air Air not locate Filter Senso- Do bank OK sensor here Bend or other obstruction 6Duct widths - minimum Return air inlet ( 9 6Duct widths minimum Remote Indicator Options 2098-9806, Remote Test Station, provides a remote Red LED status indicator and a remote test key switch mounted on a single gang stainless steel plate. Turning the test switch to "TEST" will initiate an alann and allow the resulting system responses to be verified. 2098-9808, Remote LED Alarm Indicator, provides a remote Red LED status indicator mounted on a single gang stainless steel plate. mm i rrrnrni Remote status indicators mount in standard single gang boxes, 2"W x 3"H with a minimum depth of 2" (51 mm W x 76 mm H x 51 mm D), supplied separately. S I F! PJ Model Description Compatibility 4098-9750 In-Duct Sensor Housing without relay Simplex 4010, 4020, 4100/4100U, 4120, and 2120 CDT with beige mounting configured for MAPNET II TrueAlarm communications box, 4098-975 Simplex 4010, 4020, 4100/4100U, 4120, (not compatible with (requires 4098-9714 sensor) with relay 2120 CDT) 4098-9714 Photoelectric Sensor Head Ordered separately, required for 4098-9750 or 4098-9751 In-Duct Sensor Options, ordered separately as required, compatible with both 4098-9750 and 4098-9751 4098-9819 Adapter for 6" (152 mm) round duct, beige 4098-9824 Adapter for 8" (203 mm) round duct, beige 2098-9806 Remote Test Station mounted on single gang stainless steel plate 2098-9808 Remote LED Alarm Indicator mounted on single gang stainless steel plate Recommended Air Velocity Range UL Listed Air Velocity Range 35-600 ft/min (11 to 183 m/min) 0-2000 ft/mm (0-610 m/min) NOTE: See application discussion on page 1. Data Communications MAPNET II or IDNet, auto-selected, 1 address per housing Remote LED Current 0.6 mA, no impact to alarm current UL Listed Temperature Range 32° to 100° F (0° to 38° C) Operating Temperature Range 15° to 122° F (-9° to 50° C) Humidity Range 10% to 90% RH from 32° F to 122° F (0° C to +50° C) Wiring Connections Terminal blocks for wire size 18 to 14 AWG (0.82 mm2 to 2.08 mm2 ) Dimensions Refer to round and square duct mounting diagrams Relay Power (4098-9751 only) Voltage e8—to 32 VDC—'--, Standby Current 240 pA @24 VDC Alarm Current 30 m Ulf Power Limited Contact Rating A @ 28 VDC (for suppressed loads) Non-Power Limited Contact Rating Single form "C", 1/2 A @ 120 VAC, resistive (for suppressed loads) Round Duct Mounting Information if 7 Gasket In-Duct sensor access requires wiring with flexible conduit 4098-9824 8 Adapter L (supplied) (supplied separately) ,____•__ II + Gasket I (supplied) External mounting box 7-1/4" H x 7-1/8" W x 2" D I II 8 Inch air duct (shown for reference) Rj6 / (184 mm x 181 mm x 51 mm) o _ _________ Sensor head 4098-9714 (ordered separate) Transparent housing cover ' allows viewing of status LEDs Sensor base (supplied) ) ( 3/4" (19 mm 111 mm) 3 S4098-0021-5 11/02 S Square Duct Mounting Information [] In-Duct sensor access requires wiring with flexible conduit -. (supplied separately) External mounting box 7-1/4' H x 7-1/8" W x 2" D (184 mm x 181 mm x 51 mm) Sensor base / (supplied) 8 Inch square duct (shown for reference) Sensor head 4098-9714 (ordered separately) Transparent housing cover allows viewing of status LEDs Gasket (supplied) Gasket (supplied) 5-1/4" (133 mm) I. The 4098-9750 and 4098-9751 In-Duct assemblies include sensor base assembly, mounting box and cover, and mounting gaskets. The 4098-9714 sensor head is ordered separately. Templates are supplied for duct cutout size and location. Refer to installation instructions 574-711 for additional information. Adapters for 6" or 8" round duct applications are ordered separately. The National Fire Alarm Code, NFPA 72, Chapter 7, Table 7-2.2, Test Methods, states "Air duct detectors shall be tested or inspected to ensure that the device will sample the airstream. The test shall be made in accordance with the manufacturer's instructions." The following is a partial maintenance list to follow for In-Duct sensor locations: Periodically check In-Duct sensor locations to ensure proper air flow and to verify integrity to the standards of the installation instructions. Sensor air entry areas should be vacuumed on a six month basis or as required (sensor dirt accumulation is monitored by the fire alarm control panel). Additional considerations are contained in Installation Instructions 574-711. Tyco, Simplex, the Simplex logo, TroeAlarm, MAPNET II, and IDNet are trademarks of Tvcs ,,tera;,tional Services AG or its at/iliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks q1 the National Fire Prelection Association (NFPA). TEPG-US 91 Technology Drive• Westminster, Massachusetts •01441-0001 USA S4098-0021-5 11/02 eSirr1pIex © 2002 TEPG-US (a Tvco company). All rights ,exoroed. Al/specifications and other in/brmnation Www.tepg.com shown were current as of document revision dam and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE MIRE LISTING No. 3240-0026:220 Page 1 of 1 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 *FAX (978) 731-8881 DESIGN: Model 4098-9750 -9751 9752, -9753 and -9681 duct detector units. Models 4098-9752, - 9753 and -9681 conTfof a thermal plastic enclosure, electrical component, a listed smoke detector 4098-9714 (CSFM Listing No. 7272-0026:218) or 4098-9601 (CSFM Listing No. 7272-0026-219), a detector base and a sampling and exhaust tube. Model 4098-9601 detector head is intended for use only with Model 4098-9681 duct detector unit. Models 4098-9750 and -9751 consist of a steel box, an extension nipple, electrical components (mounted inside the box), a listed smoke detector Model 4098-9714 (CSFM Listing No. 7272-0026:218) and a detector base. Refer to listee's data sheet for additional detailed system description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. isMARKING: Listee's name, model designation, air velocity rating and UL label. APPROVAL: Listed as a duct detector unit for use with separately listed compatible fire alarm control units. Intended for use with Models 4098-9791, -9792, -9682, -9683 or -9788 detector base. For indoor use only. *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 8, 2009 Listing Expires June 30, 2010 0 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division • SimpIex TrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSyncTM Operation Audible/Visible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable I'kui*i Audible/visible (AN) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount: Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately frorn strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair SmartSync horn activation of Temporal pattern, March Time pattern (at 60 BPM), or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Operation requires connection to a compatible SmartSync operation NAC or to SmartSync Control Module (SCM) 4905-9938 Wall mount ANs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional UL/ULC listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.) Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount ANs* Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Regulated circuit design ensures consistent flash output and provides controlled inrush current Listed to UL 1971 and ULC S526 Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern) Listed to UL 464 and ULC S525 Wall and Ceiling Mount A/Vs Jsrintic Multi-Candela TrueAlert ANs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount A/V housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount ANs install using standard 4" electrical boxes. Color choice is determined by model number. T1 rnrf,L1 During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. * Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:317 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E, Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest Status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Simplex multi-candela SmartSync two-wire horn/strobe appliance operation is protected under one or more of the following U.S. Patent Numbers: 5,559,492; 5,622,427; 5,865,527; 5,886,620; 6,281,789; 6,954,137; 7,005,971; and 7,006,003. S4906-0002-5 9/2009 Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117. 1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). 01TWI&TTIMPITIM I SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on- until-reset." U'TT T11 F j7 Ii.ij i'*I Multiple Strobes. When multiple strobes and their 4006, 4008, 4100U, and 4010 Fire Alarm Control reflections can be seen from one location, synchronized Panels (refer to individual product data sheets for more flashes reduce the probability of photo-sensitive reactions information) as well as the annoyance and possible distraction of 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation SmartSync Control Module (SCM) 4905-9938 (refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination I •i.i. PTI tTh horn/strobe notification appliances. Multi-Candela A/Vs O_Q%Vzt Mounting I Housing Color "FIRE" Lettering Description 4906-912 I Red I White I I Wall I I I I 4906-9129 White Red Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9128 Red White I Ceiling control 4906-9130 White Red Wall Mount A/V Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 5-3/8" H x 5-1/4" W x 1-5/8" D 4905-9940 White surface mounted boxes (136 mm x 133 mm x 41 mm) depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-945 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D': (200 mm x 130 mm x 70 mm) Optional Sound Damper; package of 20; field installer- adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1-3/4" Diameter (44.5 mm) NOTE: After Sound Damper installation, measure soLrld level to ensure with 0.31" (8 mm) sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class Aojtput; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description Dimensions 4905-9994 Red cover with white "FIRE" lettering 5-1/8" H x 5W x 1-1/2" D 4905-9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount A/V Adapter Model Description Dimensions 49059961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mill x 154 mm x 79 mm) 49059927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2" x 6-1/8" x 3" (216 mill x 156 mm x 76 mm) 49059928* Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White I Surface Mount Adapter Box Extension, use to cover I 1-1/2" deep surface mounted boxes 4-3/4" x 6-7/8" x 1-1/2' deep, (121 mm x 175 mm x 38 mm) 4905-9916 Red * UL listed by Space Age Electronics Inc. S4906-0002-5 9/2009 2 rp Removable cover (tool required) AN Specifications S Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 DC; see Note I below Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Model Type Wall Mount Ceiling Mount Horn Output Sound Type (see Note 2) Steady Coded Steady Coded Ratings (see Note 2 for Reverberant Chamber Test, polar dispersion per UL 464 @ loft (-3m) 86 dBA 82 dBA 87 dBA 83 dBA reference) Anechoic Chamber Test, per ULC S525 3 m (-10 ft) 88 dBA 94 dBA 9OdBA 98 dBA Wall Mount Housing Dimensions (with lens) 5-1/8" H x 5W x 2-3/4" D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 75 mA 116 mA 221 mA 285 mA at other voltages 24 VDC Reference RMS Currents 18 VDC 196 A ._rri m A 253 mA 74 77 mA 14Tff(A 190 mA Ceiling Mount Housing Dimensions (with lens) 4-3/4 L" x 6-7/8" W x 2-5/8" D (121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 76 mA 117 mA 222 mA 284 mA 57 mA 88 mA 167 mA 213 mA NOTES: 1. "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Polar dispersion per ULC S525 testing = -3 dBA at +1-40" off-axis; -6 dBA at +1- 50" off-axis. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) ii r1Trnrn9 Mounting is compatible with single gang, double gang, and rVT 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others Optional 4905-9838 i Sound Damper, field attached to attenuate sound 5 to 6 dBA _I Wiring access hole Wiring terminals for SmartSync operation 1it EE: Double gang (3) Transparent housing and lens assembly Intensity selection 110 plug, accessible only from rear of housing; 15 factory setting is 15 cd Strobe intensity viewing slot IMPORTANT!WALLMOUNT INSTALLATIONHEIGHTREFERENCE Bottom of lens is either even with, or slightly Electrical above bottom\ outline of compatible 1'box boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80' and not greater than 96" above the finished floor 1• _______ 3 S4906-0002-5 9/2009 Ceiling Mount AN and Guard Installation Reference S Ceiling reference, 4" (1102 mm) square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1/2' (38 mm) minimum depth required for surface mounted electrical box L Four mounting clamps included, two each side ,-Ceiling reference, flush mounted box Optional 4905-9915/-9916 Adapter, recommended for surface mounted box _ Wiring terminals are ( located behind the housing FJII Optional 4905-9927 Red Wire Suard End View ------------------------------------- Strobe intensity viewing slot - . Intensity selection plug, accessible only from rear of lens housing; factory set:ing is 15 cd -------------------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt S 0 4905-9931 Adapter Plate 975-9145 Box 0 _____ 0 / 4905-9931 Adapter Plate / 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (102 mm) square rr— box profile, 1-1/2" (38 mm) deep FF'..' Ep Optional 4905-9961 Wire Guard AN Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco is a registered trademark of Tyco International Services GnibH and is used tinder license. Simplex. the Simplex logo, ID/Vet. TrueAlert. and SmartSync are trademarks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are it of the National Fire P,-otection As.eociation (NFPA). Simplex93 Tyco Safety Products Westminster• Westminster, MA • 01441-0001 USA S4906-0002-5 9/2009 a www.tycosafetyproducts-usa-wm.com © 2009 Tyco Safety Products Westminster. All rig/its reserved. All specifications and other information sIt at rn itore cttrtettt as uIdocu,nettt revision (late and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:317 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Mod&Z4906-912>7 906-9129 wall mount and Models 4906-9128 and 4906-9130 ceiling mount horn/strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, ll0cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. S APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used with listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are used with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation Instruction Manual for details. 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: Authorized By JUNE 15, 2009 Listing Expires June 30, 2010 FRANCIS MATEO, Program Coordinator Fire Engineering Division • 5®Simplex TrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSyncTM Operation Compatible C C I Ttu I4.1 Visible only (VIO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAG) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Listed to UL 1971 and ULC S526 Strobes provide synchronized flash for use with: 4006, 4008, 4010, and 4100U Series fire alarm control panels with NAGs selected to provide strobe synchronization or SmartSync two-wire control** 4009 IDNetTM NAG Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SGMs) that provide Class B or Class A output from conventional NAG inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex") 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes* * Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 131441 of the California Health and Safety Code, See CSFM Listing 7125-11026:316 for allowable values and/or conditions concerning material presented in this document. Ills subject to re-examination, revision, and possible cancellation. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Wall Mount Strobes F I R E :1 Ceiling Mount Strobes I llAsnrintlnn Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. 771 Y1 rnrE rtr During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. {1 E1(Ii1' Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). ** Simplex multi-candela SmurtSync two-wire horn/strobe appliance operation is protected under one or more of the following U.S. Patent Numbers: 5559492; 5,622,427; 5,865,527; 5,886,620; 6,281,789; 6,954,137; 7,005,971; and 7,006,003. S4906-0001-4 9/2009 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. I Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). SmartSync two-wire control is available from: 4006, 4008, 4100U, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extenders (refer to data sheet S4009-0002) SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Product Selection Multi-Candela Visible Notification Appliances (Strobes) ite& Mounting I Housing Color I 'FIRE" Lettering I Description 4906-9101 Wall Red White j White Red Multi-candela strobe with intensity selectable as: 4906- ~103 15, 30, 75, or 110 candela; synchronized flash rate: 4906-9102 Ceiling Red White SmartSync two-wire control compatible I 4906-9104 I White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red I Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W x 1-5/8" D 4905-9940 White deep surface mounted boxes (136 mmx133 mmx4l mm) Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mmx130 mm 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 min x 79 mm x 1.5) S Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, 4905-9922 Class A requires 5 mA for power 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" (102 mm) square box Replacement Covers and Guards Model Description 4905-9992 Red cover with white "FIRE" lettering For Wall mount strobes 4905-9993 White cover with red "FIRE" lettering 49059961* Wa l mount Red wire guard with mounting plate, compatible with 49059926* Ceilling mount semi-flush or surface mounted boxes * UL listed by Space Age Electronics Inc Dimensions 1-3/8" x 2-7/16" x 13/16" (35 mm x 62 mm x 20 mm) 4" x 4-1/8" x 1-1/4" D (102 mm x 105 mm x 32 mm) Dimensions 5-1/8" H x 5" W x 1-1/2" D (130 mm x 127 mm x 38 mm) 6-1/16" H x 6-1/16" W x 3-1/8" D (154 mm x 154 mm x 79 mm) 6-1/8" x 4-3/8" x 2-7/8" deep (156 mmxlii mmx73mm) S4906-0001-4 9/2009 Mounting is compatible with single gang, double gang, and 4(102mm) square boxes, 1-1/2" (38 mm) deep, by others Wiring access hole Wiring terminals Th Th_Th 0 / / fl Mounting Holes: '4" square (4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection .110 .75 plug, accessible only from rear of housing; 15 factory setting is 15 cd A IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly Electrical outline above bottom\ of compatible 1box oxe NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor U S tro be S pec if icatu ons Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC; see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm 2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5" W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 60 mA 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC at other voltages 24 VDC --- 53 mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4-3/4" Lx 2-5/16" W x 2-5/8" D (121 mm x 75 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 111 mA 207 mA 281 mA 50 mA 83 mA 155 mA 211 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) histallation Reference, Surface or Semi-Flush Wall Mounting Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-4 9/2009 4905-9931 Adapter Plate 4905-9931 Adapter Plate nal Wire Guard eference only, can be used on other mounting options) I Ceiling Mount Strobe Installation Reference Single gang box (Wiremold V5744S) 2-1/4' (57 mm) deep, supplied by others Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with Clips (ERICO No. 512 or equal) Ll 4905-9910 Adapter Plate, required for J 7 surface mount with handy box unless c7' 7 using the 4905-9926 wire guard I I I elling mount strobe Optional 4905-9926 wire guard with mounting plate - - - Strobe intensity I viewing slot Intensity selection plug, accessible only from rear of lens: housing; factory setting is 15 Cd --------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt S Surface Mounting Reference with Optional Adäptar Skirt and Optional Wire 3uard Surface mount conduit an-i box shown for refererca 4" (102 mm) square box profile, 1-1/2" 38 mm) deep Optional 4905-9961 Wire Guard Strobe Optional Surface Mount Acapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (Conduit knCCkouts are provided on all /ow sides) S Tyco is a ,-egisiered trode,na,-k of Tyco International Services G,nbH and is used under license. Simplex. the Simplex logo, IDNet. TrueAlert. and SwatS roe Ors o'adeooi'ks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and Notional Fire Alarm Code are registered trademarks of the National Fire Prowctioa Association (NFPA). - MpleX Tyco Safety Products Westminster Westminster, MA 01441-0001 USA S4906-000'1-4 9/20C9 a www.tycosafetyproducts-usa-wm.com - D2009 Tyco Safety Products Westminster. All rights reserved. All specifications and oilier information shown were current as ofdocu,nent revision date and are subject to e iange it Ohm it nsrioe. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:316 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Model 4906-9101 9102, -9103, and -9104 multi-candela, non-addressable, synchro?TRt!obe lights. Models 4906-9101 and —9103 are for wall mount. Models 4906-9102 and —9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division PAM SERIES MULTI-VOLTAGE RELAY MODULES The PAM Series Relays are encapsulated multi-voltage devices with "flying" leads that offer versatile, reliable performance in a convenient package. Several of the versions provide a red LED which, when illuminated, indicates coil energization. The PAM Series Relays are packaged with a self-tapping screw and a piece of double sided tape for easy installation almost anywhere. The relays are also packaged with wire-nuts to aid installation. PAM Relays are ideal for applications where remote relays are required for control or status feedback. They are suitable for use with HVAC, temperature control, fire alarm, security, energy management, lighting control systems and building automation systems. PRODUCT DESCRIPTION PAW The PAM- I Relay provides 10.0 Amp form C contacts. The relay may be energized by one of three input voltages: 24VDC, 24VAC, or I 2OVAC. The input voltages are V polarity sensitive and diode protected. A red LED is provided which, when illuminated, indicates the relay coil is energized. ) PAM-2 The PAM-2 Relay provides 7.0 Amp form C contacts. The relay may be energized by one of two input voltages: I 2VDC or 24VDC. The input voltages are polarity ... sensitive and diode protected. A red LED is provided which, when illuminated, indicates the relay coil is energized. PAM-4 The PAM-4 Relay provides 10.0 Amp form C contacts. The relay may be energized across a wide voltage range from 9VDC to 40VDC, making it ideal for I 2VDC and 24VDC EOL circuits. The I SmA operating current is constant across the operating range. The input voltages are polarity sensitive and diode protected. .Air Products and Controls Inc. 1749 E. Highwood Pontiac, M148340 (888) 332-2241 (248) 332-8807 Fax www.ap-c.com PAM-SD The PAM-SD Relay provides 7.0 Amp form C contacts. The relay may be energized by an input voltage between I 8VDC to 32VDC, making it ideal for 24VDC NAC circuits. The input voltages are polarity sensitive and diode protected. The PAM-SD provides an additional set of wires for redundant input voltage (circuit supervision pass through). LISTED CSFIVI LISTED MEAAPPROVED Distributed By: A HALMA GROUP COMPANY WIRING WHT -RELAY ENERGIZED LED BLU N c 10.0 AMP H NC RED ORGNC,J CONTACTS 120VAC @0.019A -24VAC © 0.031A 24VDC @ 0.015A PAM-1 RELAY ENERGIZEC LED BLU EIV(-) +24VDC Ocr 5A GR GRY bl jE IN 7.0 AMP +12VDC RED NO CNTACTS PAM-2 TO 4OVDC YELNC 10.0 AMP 9VDC (+) RED BLU c ORG NO) CONTACTS O.015A -I PAM-4 (-) 18VDC WHT BLU \) 0.t5A YEL TO 7.0 AMP 32VDC C ORG CONTACTS RED PAM-SD PRODUCT SPECIFICATIONS IVIJLJLL iNLJIViDfl. r.uvI - I mlvi rp%IvI -" COIL VOLTAGE: 24VAC/24VDC/120VAC 12VDC/24VDC 9 tc. 40VDC 1810 32'IDC POLARIZED: YES YES YES YES ENERGIZED LED INDICATOR: YES YES NO NO CURRENT REQUIREMENT @I2VDC 15mA 5mA @24VDC 15mA 15mA 15mA @24VAC @120VAC 31 m 19mA CONTACT CONFIGURATION: (1) SPDT Dry Form "C" (1) SPDT Dry Form "C" 1(1) SPDT Dry Form "C" (1) SPDT Dry Form "C" CONTACT RATINGS: (Contact rating/ Power Factor) @5VDC @24VDC 250pA / .35 250pA / .35 250pA 250pA / .35 7A .'.35 7A / .35 1 7A 7A / .35 @120VAC 10A 7A/.35 10A 7A/.35 WIRE LEADS: 12"/13AWG 12"/18AWG 12"/18AWG 12"/18AWG AMBIENTTEMPERAT,JJRE: (@100% RH, Condensing) -58°F to 185°F (-50°C 1085°C) -58°F to 185°F (-50°C to 85°C) -58°F to 185°F (-50°C to 85°C) -58°F to 185°F (-50°C to 85°C) CONSTRUCTION: 100% Potted (Sealed) with "Flying" Leads MOUNTING: Pre-Drilled mounting screw hole and self tapping screw provided. Double sided tape provided. DIMENSIONS: H W D 1.5" (38.1mm) . 1.5" (38.1mm) 1.5" (38.1mm) 1.5" (38.1mm) 1" (25 4mm) 1" (25.4mm) .1" (25.4mm) 1.875"(30.16mm) .875" (22.2mm) .875" (22.2mm) .875" (22.2mm) .8125" (20.64mm) LISTINGS AND APPROVALS: UL*: MEA: UOXX/2/7.S3403 UOXX/2/7.S3403 UOXX/2/7.S3403 UOXX/2/7.S3403 73-92-E Vol. 21 73-92-E Vol. 21 73-92-E Vol. 21 73-92-E VcI. 25 7nnA nn1-i ni 7'0n-1 nnt i ni 71nni nnLt'i ni 7°nn-1 nnai ni °UOXX=Control Unit Accessories, System; /2=also Component; /7a1so Certified (ci' Canada NOTICE: The information contained in this document Is intended only as a summary and is subject to change without notice. The products described have voecific instructional/ installation documentation, which covers various technical, approval, code, limitation and liability information, copies of this documentation along with any general )rsduct warning and limitation documents, which also contain important information, are provided with the product and are also available from Air Product; and controls Inc. The information contained in all of these documents shculd be considered before specifying or using the products. Any example applications shown are subject to the most current enforced local/national codes, standards, approvals, certifications, and/or the authority having urisdiction. All of these resources, as vetl as the specific manufacturer of any shown or mentioned related equipment, should be consulted prior to any implementation. For further information or assistance concvming the p'sducts, contact Air Products and controls Inc. Air Products and controls Inc. reserves the right to change any and all documentation without notice. © Air Products and Controls Inc. 2002 CS-RL-1 VER0502 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No 7300-1004:101 Page 1 of 1 CATEGORY Misc. Devices/Control Unit Accessories LISTEE Air Products and Controls Inc., 1749 East Highwood, Pontiac, Ml 48340 Contact: Richard Steele (248) 332-3900 FAX (248) 332-8807 DESIGN: Models MR-101/C, MR-104/C, r4 T,M-201/CX, MR-204/C, MR-204/CX, PAM-11, PAM-2, PAM-2X, PAM-3, PAM-AM-SDJJIC-1, RIC-2, *R1C3 *R1C4 *MRRIC..301 *MRRlC305 *MRRlC401 and *4Q5 relay modules. Models MR-101/C, -201/C and -201/CX may employ suffix -R or 5 *The MR-RlC series relay modules will employ /T, /C, or /C/R suffixes. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. S APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *Rev. 03-01-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2009 Listing Expires June 30, 2010 5 Authorized By FRANCIS MATEO, Program Coordinator Fire Engineering Division S SimplexGrinnell BE SAFE. A Tyco International Company SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www. sirnolexorinnell. corn License Number: 802591 SIMPLEX GRINNELL L P Business Information: P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number: (916) 283-0300 Entity: Partnership Issue Date: 12/28/2001 Expire Date: 12/31/2009 License Status: This license is current and active. All information below should be reviewed. Classifications: 010 ELECTRICAL C16 FIRE PROTECTION CONTRACTOR This license filed Contractor's Bond number 81880913 in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2007 Bonding: This license filed Bond of ()iiIifvinn Individual number 81880915 for RONALD (II RPRT MAYLE in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2007 This license filed Bond of Qualifying Individual number 82165933 for DEAN RAYMOND ENGEL in the amount of 2. $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 04/03/2009 This license has workers compensation insurance with the NATIONAL UNION FIRE INSURANCE COMPANY OF PITTSBURGH, PA Workers' Policy Number: WC 060-16-8740 Compensation: Effective Date: 10/01/2009 Expire Date: 10/01/2010 Miscellaneous ' Information: 10/28/2005 ASB CERTIFICATION REMOVED 9/29/2009 REV.#: 0 PROJECT #: 480-XXXXXX-XX / XXXX)OO(XX SimplexGrinnell BE SAFE. A Tyco International Company SimplexGrinnell LP 3568 Ru ffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www. sirnolexarinne/I. corn SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SirnplexGr nn-3-1 hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in mateial 0 workmansiip. This warranty is made to the purchaser of this equipment and is in lieu of all other Narranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any cirect, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the subnitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LCCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST. I' 9/29/2009 REV.#: 0 PROJECT #: 480-XXXXXX-XX / XXXXXXXXX RECORD OF COMPLETION ff\IOccDfO Name of Protected Property: TRI-City Wellness Address: 6250 El Camino Real Carlsbad Ca 92009 Rep of Protected Prop. (name/phone:) Authority Having Jurisdiction: Carlsbad Fire Department Address/Phone Number: 1. Type(s) of System or Service X NFPA 72, Chapter 3 - Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 3 - Emergency Voice/Alarm Service Quantity of voice/alarm channels: Quantity of speakers installed: Quantity of telephones or telephone jacks included in system: NFPA 72, Chapter 4 - Auxiliary Indicate type of connection: Local energy: Shunt: Location and telephone number for receipt of signals: Single Multiple: Quantity of speaker zones: Parallel telephone: NFPA 72, Chapter 4 - Remote Station Alarm: Supervisory: NFPA 72, Chapter 4 - Proprietary If alarms are retransmitted to public fire service communications center of others, indicate location and telephone number of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 4 - Central Station The Prime Contractor: Central Station Location: Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-Way Radio Digital Alarm Communicator Two Way Radio Others Means of transmission of alarms to the public fire service communications center: System Location: Organization Name/Phone Representative Name/Phone Installer SimplexGrinnell Bob Ciereck 858-633-9100 Supplier SimplexGrinnell Kevin Wunderly 858-633-9100 Service Organization SimplexGrinnell Brian Pipkin 858-633-9100 Location of Record (As-Built) Drawings: Maintenance/Facilities Location of Owners Manuals: Same Location of Test Reports: Unknown A contract, dated N/A , for test and inspection in accordance with NFPA standard(s) No(s) , dated , is in effect. Record of Completion 2. Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by SimplexGrinnell on /2 ./2/t'9 , includes the devices shown below, and has been in service since: same X NFPA 72, Chapters III 31 41 51 61 7 (circle all that apply) X NFPA 70, National Electrical Code, Article 760 X Manufacturer's Instructions -Other (specify): Signed: Date: ________ Organization: SimplexGrinnell 3. Record of System Operation All operational features and functions of this system were tested by: SimplexGrinnell on , and found to be operating properly in accordance with the requirements of: X NFPA 72, Chapters III 3! 41 51 61 7 (circle all that apply) X NFPA 70, National Electrical Code, Article 760 X Manufacturer's Instructions Oer (specify)/ Signed: ü4V t9-1 Date: q 12f/~, /,' Organization: SimplexGrinnell 4. Alarm-Initiating Devices and Circuits (use blanks to indicate quantity of devices) MANUAL 7 Manual Stations x Noncoded, Activating Transmitters Coded Combination Manual Fire Alarm and Guard's Tour Coded Stations AUTOMATIC Coverage: Complete: x Partial: ( Smoke Detectors Ion x Photo , Duct Detectors Ion x Photo Heat Detectors FT Sprinkler Waterflow Switches: Transmitters Noncoded, Activating Coded Other (list) 5. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) SPRINKLER SYSTEM Coded Valve Supervisory Signaling Attachments Valve Supervisory Switches, Activating Transmitters Building Temperature Points Site Water Temperature Points Site Water Supply Level Points Electric Fire Pump: Fire Pump Power Fire Pump Running Phase Reversal Engine-Driven Fire Pump: Selector in Auto Position (I) Engine or Control Panel Trouble Fire Pump Running Engine-Driven Generator: Selector in Auto Position (I) Control Panel Trouble Transfer Switches Engine Running Other Supervisory Function(s) (specify): Record of Completion 6. Alarm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: Types and quantities of alarm indicating appliances installed: Bells Inch Speakers Horns Chimes Other: x Visual Signals Type: Xenon _____-with audible without audible Local Annunciator : Location___________________________ 7. Signaling Line Circuits Quantity and Style (see NFPA 72, Table 3-6) of signaling line circuits connected to system: Quantity: Style Y 8. System Power Supplies Primary (Main): Nominal Voltage: 120 VAC Current Rating: 6 A Overcurrent Protection: Type: Circuit Breaker Current Rating: 20 A Location: Panel: 11 Circuit # 2. 7 Secondary (Standby): X Storage Battery: Amp-Hour Rating 12 AH X Calculated capacity to drive system, in hours: x 24 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency or Standby System used as backup to Primary Power Supply, instead of using a Secondary Power Supply: Emergency System described in NFPA 70, Article 701 Legally Required Standby System described in NFPA 70, Article 701 Optional Standby System described in NFPA 20, Article 702, which also meets the performance requirements of Article 700 or 701. System Software (a) Operating System Software Revision Level(s) , I, (b)Application Software Revision Level(s) i , (c) Revision Completed by: Mike Duer SimplexGrinnell (name) (firm) 10. Comments ri2crSo/O (signed) fd'r Central Station or Alarm Service Company (title) (date) Frequency of routine tests and inspections, if other than in accordance with the reference NFPA standards: Unknown System deviations from the referenced NFPA standard(s) are: none (signed) for Central Station or Alarm Service Company (title) (date) Upon comple on of the system(s) satisfactory test(s) witnessed of required by the authority having jurisdiction; - -.------.---------- I 0 (signed) representative bLjYie authority having jurisdiction (title) (date) Record of Completion