Loading...
HomeMy WebLinkAbout880 CARLSBAD VILLAGE DR; ; AS130105; PermitCity of Carlsbad Sprinkler Permit Permit No: AS 130105 880 CARLSBAD Job Address: VILLAGE DR Permit Type: SPRINK Parcel No: 2033541600 Status: APPROVED Applied 7/3/2013 Approved: 7/16/2013 Lot #: 0 Reference No.: Issued: 7/16/2013 PC #: Inspector: Project Title: SUBWAY T.I. T.I. ADDITION OF 15 SPRINKLER HEADS-1,500 SF Applicant: AMERICAN AUTOMATIC FIRE SUPPRESSION SUITE B 9510 PATHWAY STREET SANTEE CA 619-562-3010 Owner: BURECK CAPITAL L L C 1923 DENTRO DE LOMAS BONSALL CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 268 0 268 0 COV Worldwide Contacts www.tyco1ire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition tothe stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.61K, 1/2 NPT TY323 ......Pendent 5.61K, 1/2 NPT Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/bar112) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Natural Brass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button ....... . ...... Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze Page 1 of 4 JANUARY 2013 R5 0 TFPI72 F- - 2" (50,8 mm) 13 WF (34mm) Fl DEFLECTOR * PENDENT UPRIGHT • . • 4 NOMINAL :0 dJQ (50,8 mm) CROSS SECTION 2-7/8'(73,o mm) DlA. RECESSED PENDENT TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2' 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS 1t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be Installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in afire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) FLUSH 3/8±5/16 I (9,5±7,9 mm) / _J MOUNTING / 1/8" (3,2 mm) J SURFACE / /' CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON - 2-7/8" DIA. - (73,0 mm) FACE OF SPRINKLER - 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4" ____________ *(3,,28nmm) FLUSH (7,9±6,4 mm)1/2" (12,7 mm) 17, MOUNTING I SURFACE CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 40f4 P/N* 77 - XXX - X - XXX I I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2 NPT) TY313 4 SIGNAL WHITE (RAL 9003) 371 5.6K PENDENT (1/2 NPT) TY323 3 PURE WHITE (RAL 9010)** 175 175-F (79-C) Use suffix "I" for ISO 7-I connection; 9 CHROME PLATED for example, 77-370-4-175-I - Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS - PART NUMBER SELECTION - Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (SIN), K=5.6, (Upright or Pendent) Sprinkler Quick Response, (specify) temperature rat- ing, (specify) finish, P/N (Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 135 135°F (57°C) 155 155°F (68°C) 200 200°F (93°c) 286 286°F (141°C) GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. X1w ridWide www.tyco-fire.com Contacts Series RFII - 56 K-factor "Royal Flush 11" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1!2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- IMPORTANT Always refer to I Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFlI Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. MARCH 2013 TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-E) as Quick Response. TY3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a!10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a!9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/p51112 (80,6 LPM!barll2) Adjustment 1!2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFPIBI SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO fl RETAINER SUPPORT II WITH THREAD CUP UNTIL 0 0 '1_- DIMPLES MOUNTING ( SURFACE IS 11 EJECTION FLUSH WITH 11 SPRING CEILING H / SOLDER ' '-_ COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY TFPI8I Page 2 of 4 Physical Characteristics Frame ...................Bronze Support Cup..............Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly ......... Beryllium Nickel w/ TEFLON Cover Plate................Brass Retainer ...................Brass Ejection Spring......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. 1/2 NPT FRAME SUPPOR1 CUP WlT ROLL FORK/ THREADS GUIDE PINS (2) Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and DEFLECTOR ------------- :LECTOR ROPPED POSITION) EALING SEMBLY CAP BULB PRESSION CREW 3/16 to 11/16" (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B MANUFACTURER DEFLECTOR PRESET GAP IN DROPPED 3/32 (2,4 mm) POSITION COVER PLATE DIAMETER DIMENSION A COVER PLATE RETAINER ASSEMBLY 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 Arms during ceiling installation and/or finish. YOu can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. AL•1ILOi As long as the Protective Cap remains in place, the system is considered "Out of Service" Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate! Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP - ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER DIMENSION TTTd TFPI8I Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING SEAL BEVEL AS COVER \ SHOWN PLATE RETAINER ASSEMBLY AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Care and Maintenance The TYCO Series RFII 5.6 K-fac- tor, 'Royal Flush U" Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N (specify). 155°F (68°C) 200°F (93°C) TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate! Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) . . .. 56-792-0-135 56-792-0-165 Brass..... 56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003) .... 56-792-4-135 56-792-4-165 Jet Black (RAL9005) . . .. 56-792-6-135 59-792-6-165 Brushed Chrome........ 56-792-8-135 56-792-8-165 Chrome.... 56-792-9-135 56-792-9-165 Custom ........ 56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales Only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. t TEFLON is trademark of The DuPont Corporation. DYNA THREAD =11 Full Line Sch-40 Replacement Dyna-ThreatF offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics And, when used in combination with Dyna-Flow pipe, down sizing often occurs.. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of l)yna-Thread 'is protected by a clean, durable mill coating for extended shelf life and easy paint application. (9 <~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, 'BF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be. "hot-dip" galvanized to meet FM requirement for dry systems. Super 40lDyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. M. (H20 Fitted) Pcs/ Wt/Lift (21) Wt.ltift(24') WtlUft(25 In;mm In; mm Lbs/FtT Kg/rn LbVFt Kg/rn Lift Lbs; Kg Lbs Kg Lbs: Kg 1 '11.080 -1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 1056 114 1.408 1,870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11/i 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 1143 2 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 161011. Lathrop e Harvey, IL 60426 Customer Service: tilco allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-'5543 a viral part of your vvoild TUBE S coNDurr 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3-3 P: ~wIAcn P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint Ring Ihni estrainer SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. One size fits 2 '/2 and 3 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS.. cYus EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA-13 on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. FEATURES- * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. 10106 112 and 3/4 inch pipe 5 thru 8 Inch pipe P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1 thru 4 Inch pipe LISTED FOR STEEL/CPVC SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL- c® 2037EX 2551 <> Approval guide - Pipe Rangers OSLLPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171 (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION Per NFPA 13 13R. and 131) FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. 2/07 IMPERIAL MAX REC. LOAD LBS. METRIC PIPE ROD PIPE ROD 112 400 lB 314 318 400 20 10 1 25 10 11/4 318 400 32 1 to 11/2 318 400 40 2 1 318 400 50 to 21/2 318 600 65 tO 3 s's 600 80 10 31/23/8 600 10 100 4 s's 1000 S M 1250 025 IS 1/2 1250 150 12 1/2 1250 200 i Order Part #300m Marc: 112' Ring Hanger not <FM> approved T tens flO i as r am 2aM .a aio 8 2 L4$ 1.2211 A LL 2W L440 ulao a &O FIGURE 358 STRAIGILk*l1 Weight Size A B block gale. MPS/ON ln./rrsm Inlinni Thu/kg I lbs/kg ½ 3/16 0.22 0.23 8 13 22 Ui 0.1 ~ 1 0.35 0.36 10 16. 25 016 0.16 ½ 11/6 0.56 038 15 Ii 29 0.25 0.26 ~4 IN 1 116 0.84 0.85 20 22 33 0.38 739 1 1.3 '13 25 24 38 0 0.59 11/4 1% 93/4 2 2.1 37 75' 44 13.9 0.9 11h IMs 11½a 2.7 2.7 40 33 49 12 9.2 13/it 27/4 4.2 4.3 50 40 57 19 . 2 21/z 19A6 2M 6.7 6.8 65 47 68 3 3.1 3 3½ 10 10 80 56 73 4.5 4.6 31h 21A6 3½ 13 14 90 62 . 87 6 . 6.3 4 211/I6 33/4 16 17 100 43 95 1.4 7.1 5 3'16 41 27 28 125 84 114 12 13 6 314 51/4 41 41 W 08 130 19 99 8 53/i6 6 /16 79 81 200 137 167 36 37 APPROVED For Listing /.Approval details contact your AnvilStar''5 Representative. Straight Tee A1iA.Star Fire Prdc5u Division atAnvir fr6nmu110npJ Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet kTPPIAI SPF(IFIrATI( Anvil standard and extra heavy cost iron threaded fittings are Anvil standard and extra heavy Fittings in this section, sizes manufactured In accordance with ASME-Bi 6.4 (except plugs 1/4 NPS - 12NPS (8 300 DN), are included in the "List of and bushings, ASME B16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW-P-501 (except plugs and bushings the Underwriters' laboratories, Inc. WW-P,471). NOTE: Seethe Technical Data section For pressure-iernperalure ratings. Sea AnvilSiar Web site for the most current Listings and approvals. Project: Date: I Phone: Architect I Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06.005 go towww.anvilstar.com or contact your local AnvilStar representative Concentric Reducers IM1tLBtar Fire Produele bMstoo of Ant' tntemational Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet APPROVED - - - For Listing I Approval details contact your - AriviiStarov Representative. FIGURE ItK'] 1[ Size A B WOW-black NP54)Jl NI'S/ON It/mm In/mm lbs/kg 3J4 ½ 1¼6 0.4 213 IS 16 40 0.18 1/16 i'½s 0.54 15 11 43 0.26 25 1½ 0.63 20 II 33 0.29 ½ 9A6 We 0.84 15 14 49 9.38 11/4 ¼ i 21,5 1.1 32 20 25 54 0.49 1 1¼6 2½ 1.1 25 24 54 0.49 ½ 1,5 95,5 1 15 13 II 1 045 ¼ ½ We 1.2 11h 20 13 49 054 40 I ½ Wi 13 25 13 44 0,68 11/4 1 21/i 1.5 32 25 5? 066 ½ 2 2 /5 /6 51 1 0191 2 ~ ~ 2 1.9 50 20 /2 SI 0.05 2 1.8 25 I? 51 1 0.83 II:1['1I'II1p 1:T Size A 0 We lt NI'S/ON NI'S/ON heJmni lnJirrm lbs/kg 2 11/4 13A6 2½ 1.8 32 22 54 0.81 50 (0170 1½ ½ 2./16 2 40 22 50 0.9 ¼ 2 3.1 2½ 40 99 51 1.4 65 2 1 2/I6 3 50 23 65 1.4 3/4 ISle 2½ 4.3 20 24 64 2 3 2 1146 4 80 50 27 /0 LB 21/7 1¼e 21¼e 4,4 55 24 73 1 2 2 1¼e 215Ae 6.5 30 75 2.9 4 ½ Wee 3¼ 1.8 5 r!3 30 79 35 iSle 31/8 7 80 27 19 22 5 4 hue 35'ie 10 125 100 27 84 4.8 4 1¼ 37A6 14 6 1013 29 87 6.3 950 5 i½ .37Ae 16 125 29 90 1 8 6 1114 3¼ 29 800 1 IsO 32 08 13 hex end !LT FPILtI ccrtirnir Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME-B 16.4 (except plugs 1/4 NPS - 1 2NPS (8 - 300 DN), are included in the "list of and bushings, ASME B 16. 14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW-P-501 (except plugs and bushings the Underwriters' laboratories, Inc. WW-P-471). NOTE: Seethe Technical Data section for pressure-temperature ratings. See Asivil5torWeb site For the most current listings and approvals. Project: Date: I Phone: Architect I Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FIN Approved pressure ratings, versus pipe sciedteIe, REV03.03.0o.0011 go to www.arivilstar.com or contact your local AdvilStar representative 'i 800 Elbow - Straight iiñ1h...Star Fke Product, Division of Anvir international Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet APPROVED For Listing / Approval details contact your AnvIlStarTm Representative. FIGURE cI. 900 ELBOW Ial:1[e]k weight Size A 8 black gale. NPS/DN !n./mrn mjnim lbs/kg ½ ½ % 0.16 0.17 8 13 22 £1.07 0.08 /l6 1½e 0.25 0.26 10 14 24 0.11 0.12 ½ 11116 11/8 0.4 0.41 15 17 29 0.18. 0,19 1/4 13/16 15/e 0.6 0.61 20 22 33 6.27 0.28 1 15M 1i½, U.n 0.95 * 7.1 24 30 0,47 0.43 1 V11i3 13/i 1,4 1.5 32 77 44 0.65 0.66 1 1h l½e Irl 7116 2 2 40 33 49 0.91 2 14e 2% 3.1 3.2 50 40 57 1.4 1.5 21h 113A6 2/u 4.9 5.1 65 4.7 68 7.2 2.3 3 The 5A 7.2 7.4 80 56 79 3.3 3.4 4 2% 313/16 12 13 100 68 98 53 5.) 5 The 41h 21 - 125 84 1 14 13 6 31/8 5½ 31 33 150 78 130 14 15 8 53/1e 66 65 67 260 132 1 167 29 /0 tTFPIAI sDFtIFIrATIr Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME-Bi 6.4 (except plugs 1/4 NIPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B 16,14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW-P-501 (except plugs and bushings the Underwriters' Laboratories, Inc. WW-P-47 1). NOTE: Ste the Technical Data section for pressure-temperature ratings. See AnvilStar Web site for the most current listings and approvals. Project: Date: I Phone: Architect I Engineer'. Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06.001 go to www.anviIstaVcom or contact your local AnvilStar representative Branch Outlet NJ1i..Star Fir,, Products Civutan of Anvl noSusof Submittal Sheet The Gruviok Fig. 7044 Branch Outlet is For direct connection of sprinkler heads and drop nipples. Just cut a hole, saddle up and fasten it with the U-bolt. The branch outlet provides an economical, quick, and easy outlet at any location along a pipe. Specially engineered to conform to the pipe O.D., the Fig. 7044 provides a leak tight reliable seal in both positive pressure and vacuum conditions. Ductile iron housings with Grade E gasket and carbon steel U-bolt (s/a" dia.) with Flanged nuts. Ductile iron housings is available black. The maximum working pressure for all sizes is 175 PSI (12.1 bar). k~@ APPROVED For Listing I Approval details contact your AnvilStai".Repreaentative. MATERIAL SPECIFICATIONS - HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12. U-BOLT & NUTS: Plated U-bolt conforming to ASTM A-307 with plated hex nuts conforming to ASTM A-563. COATINGS: Li Plain Other (Specify): For other Coaling requirements contact an ArwilStor Representative. LUBRICATiON: Q Standard GruvlokGruvlok XtremeTM (Recommended for dry pipe systems and freezer applications.) I Other (Specify): GASKETS: materials Properties as designated in accordance with ASTM D-2000 CT Grade 'E° EPDM (Green color code) -40°F to T50°F (Service Temperature Range) (-40°C to 66°C) Recommended for water service, diluted acids, alkalies solutions, salts, oil-free air and many chemical services not involving hydrocarbons, oils or gases. NOT FOR USE WITH HYDROCARBONS. 1j Other PROJECT INFORMATI ON: 1IITf1S1tAltiU Project: Date: Phone: Architect I Engineer: Contractor: Address: Notes 1: Notes 2: PAGE tOE GruViok Couplings, Fittings, Flanges, Clamps For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 0303.061DO16 go to www.anvilstar.com or contact your local AnvilStar representative V Branch Outlet AN-VA.Star- Fire ProdUC14 DS,izion OfArewir Intemsficnal Submittal Sheet Hole Diameter Dimensions Spedliod Torque § Nominal Size Pipe 0.0. Mox. Wo0rking WI. Eo. Mm. Din. Max. Din. A C 7/m. MI Mox. In/DNfrmj IaJmm psVbar In/mon In/aim !nlmm In/mm In/nm, Fl Lbs/1184 Lbs/Kg 1/ix½ 1.660x0,840 175 1~ 1¼ 214t 3½ 2½? 1¼ 27 33 0.8 32x15 42.4x213 12.1 30 32 53 89 56 25 - 9,4 1°Ix/i 1.660x1.050 175 1½? 1¼ 21'16 3½ 2½? 1¼ 27 33 0.8 32s70 42,4x26.1 12.1 30 37 53 89 56 25 0.4 '451 1660x1255 175 l5lio 1¼ 2~o 31, 2½? 1¼ 27 33 09 32s25 42,4x 33.1 12.1 30 32 56 89 .56 28 0,4 1½x½ 1,900x0,840 175 ½? 1¼ 2½? 3°/i 2'½ 1¼ 27 33 0.8 lOs 15 48.3s 21.3 12,1 35 32 55 89 56 25 9,4 i½x/4 1.900x1.050 175 i~ V/s 2½? 3½ 2½? 1% 27 33 0.8 40s20 40.3.r 70 12.! 30 32 55 89 56 35 , - 84 1½ X 1.900 a 1.315 175 1½? 1¼ 2½? 3½ 2½i 1½ 21 33 0.9 40x 25 48.3s 33.7 12.1 30 32 58 89 56 38 . . 04 2 x ½ 2.375 sO.840 175 1½? 1114 21h 31A 21M 1¼ 21 33 0.8 50 IS 60.3x21.3 12.1 38 32 64 98 50 42 - - 0.4 2x1/4 2.375x1.050 175 1½? 1½ 21A 3¼ 2½2 15A 27 33 0.8 50s20 60.5x761 III 10 32 64 93 56 42 . . 94 2 x 2.315 x 1.315 175 i/u 1¼ 2¼ 31A 27hz 1'A 21 33 0.9 50x25 60.3X33.1 12.! 30 32 67 90 56 45 - 8.4 2½x¼ 2:815x0.840 175 1½? 11/4 2146 43A 27A2 2 27 33 0.8 45x15 73.0s20 12.1 28 22 69 11! 56 51 0.4 21hx~4 2.875x1,050 175 13A6 1114 2 1A6 43A 21/31 2 27 33 0.9 65x20 73,0x29? 12.1 30 37 69 III 56 SI 2½x1 2.815x1.315 175 1IA6 11/4 2/io 43A 27h7 2½ 27 33 1.0 65x25 13.0x35.1 1 12.1 1 30 1 32 1 12 1 1!! 1 58 54 1 ' . 0.5 Not for use in copper systems, § -For additional Bolt Torque information, 500 Technical Data section. IA WARNING] For dry pipe nynterns and freezer applications lubrication of the gasket is required, Gruvloktm xtrerneiM Lubricant is recommended. PAGE 2012 Gruvlok Couplings, Fittings, Flanges, Clamps For the latest UL/IJLC Listed and FM Approved pressure ratings, versus pipe schedule, 7' REV. 03.03.060007 go to www.onvilstar.com or contact your local AnvilStar representative ( 1 ' A!YiIsr.