Loading...
HomeMy WebLinkAbout2198 PALOMAR AIRPORT RD; ; FA090047; Permit12/28/2020 FA090047 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA090047 2198 PALOMAR Job Address: Status: ISSUED AIRPORT RD Permit Type: FALARM Applied 10/1/2009 Parcel No: 7602211800 Approved: 10/1/2009 Lot #: 0 Reference No.: Issued: 10/1/2009 PC #: Inspector: Project Title: THE LANDINGS T.I. FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: STANDARD ELECTRONICS 9340 STEVENS RD SANTEE CA 619-596-9950 11'A'A I1li AVIS RENT A CAR SYSTEM INC C/O ARC DEPT 6 SYLVAN WAY PARSIPPANY NJ Fees ($) Add'I Fees ($) Total ($) Balance ($) 125 0 125 0 1/1 FAO0oc4 Q&" Standard Electronics 9340 Stevens Rd. Santee, CA 92071 Ph# 619-596-9950 Fax# 619-596-8850 SUBMITTAL SHEET September 30, 2009 FILECOpy PROJECT: LANDINGS- PALOMAR AIRPORT, 2198 PALOMAR AIRPORT RD.,MS N-137, CARLSBAD ELEC.CONTR: PREVOST CONSTRUCTION, 400 S. SIERRA, STE 201, SOLANA BEACH, CA. 92075 EQUIPMENT FIRE ALARM NO SECTION ITEM QTY. DESCRIPTION MODEL NO. DATA SHEET 1 1 ANALOG ADDRESSABLE MANUAL PULL STATION MS701ADU MIRCOM SFM #7150-1656:128 ADDRESSABLE 135 DEGREE FIXED TEMP. RATE OF RISE 2 2 HEAT DETECTOR SEMli 7271-1477-114 MIX-5251RB MIRCOM 3 2 SMOKE/HEAT BASE SFM #7300-1653:109 B21OLP SYSTEM SENSOR ADDRESSABLE INPUT MODULE 4 1 MIX-M501MMIRCOM SFM#7300-1477: 113 MULTI CANDELA HORN STROBE SYSTEM 5 1 P2CR SFM #7125-1653:186 SENSOR 6 4 MULTI CANDELA STROBE ONLY SCR SYSTEM SFM #7125-1653:186 SENSOR 16 AWG/ 2 CONDUCTOR - SOLID CONDUCTORS POWER 7 1k LIMITED - FIRE PROTECTIVE SIGNALING CABLE 60990B WEST PENN SFM #7161-0859:101 14 AWG/ 1 TWISTED PAIR PLENUM - NON-SHIELDED - 8 1k SOLID CONDUCTORS 60993B WEST PENN SFM #7161-0859:101 INTELLIGENT ADDRESSABLE PULL STATIONS MS-700ADU SERIES MS-701ADu MS-710ADU Intelligent Addressable Intelligent Addressable Single Action Pull Station Dual Action Pull Station 1%M Description Mircom's MS-700ADU Series provide manual fire reporting. These high quality, die-cast metal Intelligent Fire Alarm Pull Stations are available in either single or dual action configurations with a permanently attached addressable module. The MS-700ADU Series stations are available as single or dual-action devices with key resets and a permanently attached addressable module . The addressable pull station has a pair of rotary decimal switches which allows for two digit address setting. Pulling the handle initiates the operation of the addressable module. All models are available with CAT-30 keys and mount on a standard single gang backbox, Mircom model BB-700 interior surface metal backbox, or BB-700WP weather proof backbox. Features Single or Dual Action Key resettable Permanently Attached Intelligent Addressable Module High-gloss red enamel finish Plastic breakrod Mounts on standard single gang box, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox Operation The MS-701ADU Single Action Intelligent Pull Station is operated by pulling down the handle marked "PULL HANDLE" on the front of the station. The MS-710U Dual Action Intelligent Pull Station is operated by pushing the bar labelled "PUSH BAR" and then pulling down the handle marked "PULL HANDLE". The MS- 700ADU Series Pull Stations are reset by opening the station with the key, placing the handle in the normal upright position and re-locking the station. Specifications The manual pull station shall be Mircom's MS-700ADU Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the intelligent addressable module. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. @ @ 0 S7005 S7005 7150-1477:128 CATALOG NUMBER 5928 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make Changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Specifications Switch Rating: Pull Station Dimensions: Color: Current Consumption: l Amp @3OVDC - 0.1 Amp © 125 VAC 4.9" H x 3.5" W x 2.0" D Red with raised white letters, white Pull bar with raised red letters. Standby: 400 uA Alar5 mA Surface Mount Backboxes BB-700WP Weatherproof Surface Mount Backbox BB-700 Surface Mount Backbox Dimensions: 5" H x 3.6" W x 2.0" D 0 Dimensions: 5" H x 3.6" W x 2.2" D Typical Wiring Diagram MS-70IADU and MS-7I0ADU FROM - }To NEXT STATION OR STATION > PREVIOUS 'BLK It:1 BLACK - ENDOFLINE DEVICE RED L ADDRESSABLE MODULE IAI YELLOW N.C. SWITCH NOTES: WIRE AS SHOWN SO THAT SUPERVISION OF CONNECTIONS IS MAINTAINED. MOUNT STATION TO 4" SQUARE xl 112" DEEP OUTLET BOX WITH PLASTER RING RAISED 1/2". SWITCH RATING: ALL MODELS 1A @ 30VDC, 0.1A@ 125VAC MAXIMUM WIRE SIZE: No. 12 AWG. REFER TO FIRE ALARM CONTROL PANEL MANUAL FOR ADDRESSABLE MODULE SETTING. Ordering Information &OP Model Description MS-701ADU Intelligent Addressable Key Resettable Single Action Manual Pull Station MS-702ADU Intelligent Addressable Key Resettable Dual Stage Single Action Manual Pull Station MS-710ADU Intelligent Addressable Key Resettable Dual Action Manual Pull Station BB-700 Series 700 Interior Surface Mount Backbox, Red Finish BB-700WP Series 700 Weatherproof Surface Mount Backbox, Red Finish Add suffix "NY" for New York Versions NOT TO BE USED FOR INSTALLATION PURPOSES. CON' 1vU7v;-LiK1-0-M . Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 60 Industrial Parkway Cheektowaga, New York 14227 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com CAT. 5928 Rev. 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1656:128 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Secutron, Inc, 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 732-8876 FAX (888) 660-4113 DESIGN: Models MRM-701U, -703U, -704U, -710U, -701ADU, -710ADU, -705U and -715U fire alarm boxes. These devices are manually actuated, single or dual action non-coded, fire alarm boxes for indoor use only. Units are to be mounted on standard outlet boxes or listee's Model MRM-700 backbox for indoor use only and MRM-700WP backbox for indoor and outdoor use. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC, IA, 125 VAC, IA INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees flame, model number, rating, and UL label. APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7150-1477:128 05-25-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed t h e t e s t r e s u l t s and/or other data but does not make an independent verification of any claims. This listing is not an en d o r s e m e n t o r recommendation of the item listed. This listing should not be used to verify correct operational requirements o r i n s t a l l a t i o n criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JULY 1, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division J/ INTELLIGENT LOW PROFILE SENSORS MIX-200 SERIES Mircom's MIX-200 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity is continuously monitored and reported to the FX-2000 Fire Alarm Control Panel. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level. Intelligent Low Profile Ionization Smoke Sensor (MIX-1 251 B) The Intelligent Ionization Smoke Sensor is constantly monitored to measure any change in its sensitivity due to the environment (dirt aging, temperature, humidity, etc.) It can give an advance indication to the FX-2000 analog control panel of the need for maintenance and can be specific as to where the maintenance is needed. It can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. Intelligent Low Profile Photoelectronic Smoke Sensor (MIX- 2251 B) The Intelligent Photoelectronic Smoke Sensor is constantly monitored to measure any change in its sensitivity due to the environment (dirt, aging, temperature, humidity, etc.) It can give an advance indication to the FX-2000 analog control panel of the need for maintenance and can be specific as to where the maintenance is needed. It can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. Intelligent Thermal Sensors (MIX-5251 B/MIX-5251 RB/MIX-5251 H) The Intelligent Thermal Sensors contain a dual thermistor sensing circuit for fast response. They provide open area protection with 50 foot spacing. The sensors rapid response characteristic virtually eliminates the thermal lag which is characteristic of conventional heat detectors and insures operation as soon as the temperature reaches its set point (MIX-5251 B), or upon a temperature rise of 15°F per minute (MIX-5251 RB). The MIX-5251 H provides fixed high temperature detection at 190°F. These sensors can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. Intelligent Low Profile Photoelectronic Smoke Sensor with Thermal (MIX-22511B) The MIX-2251TB has the same features as the MIX- 2251B and includes a 135°F thermal sensor. It can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. MSFM approved IVIEA 2151 approved (MIX-1251B) 2131 S6295 (M/X-12518, MIX-22518 & MIX-2251 TB) S6965 (MIX-1251B, M!X-22515& 7271-1477:122 (MIX-I251B) 7271-1477:117 148-03-E (M!X-12518) 219-02-E (MIX-22515ra) MIX-2251T8) (M(X-22518)(MIX-22518ff8) S6299 (MIX-5251B/RB/H) 57498 (MIX-52518/RBJH) 7271-1477:114 (MIX-525181R5/H) 390-02-E (M(X.5251B/RBJH) APROVO 3017998 CATALOG NUMBER AQAA NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Specifications Height 2.0 inches (51 mm) Diameter 6.1 inches (155 mm) Installed in B21OLP Base 4.1 inches (104 mm) Installed in B501 Base Shipping Weight Heat: 4.8 oz. (137 g) Photo/Photo with Heat: 5.2 oz. (147 g) Ion: 5.4 oz. (154 g) Operating Temperature Range Ion/Photo: 32°F to 120°F (0°C to 49°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) Thermal: -4°F to 100°F (-20°C to 38°C) High Temperature: -4°F to 100°F (-20°C to 66°C) UL Listed Velocity Range Ion: 0 - 1200 fpm (0- 5.1 m/sec) Photo/Photo with Thermal: 0 - 4000 fpm (0 - 20 m/sec) Relative Humidity 10% - 93% noncondensing Insect Screen Hole Size Photo: 0.016 inch (0.41mm) nominal Ion: 0.035 inch (0.89mm) nominal Thermal Ratings Fixed Temperature Setpoint: 135°F (57°C) Rate of Rise Detection: 15°F/mm. (8.3°C/mm.) High Temperature: 190°F (88°C) Voltage Range 15-32 volts DC peak Standby Current Ion/Thermal: 150 uA @ 24 VDC (without communication, LED off) 200 uA @ 24 VDC (one communication every 5 sec. with LED enabled) Photo/Photo with Thermal: 250 uA @ 24 VDC (without communication, LED off) 300 uA @ 24 VDC (one communication every 5 sec. with LED enabled) LED Current (max.) 6.5 mA @ 24 VDC (on) Note: Mounting sensors outside of the specified temperature ranges will cause sensor failures and erratic panel operation. Ordering Information Model Description Intelligent Addressable Analog Sensors 17. MIX-1251B Intelligent Low Profile Ionization Smoke Sensor MIX-2251B Intelligent Low Profile Photoelectronic Smoke Sensor MIX-2251TB Intelligent Low Profile Photoelectronic Smoke Sensor c/w 135°F Fixed Temp. Thermal Sensor MIX-5251B Intelligent Low Profile Fixed Temp. Thermal Sensor 135°F MIX-5251RB Intelligent Low Profile Fixed Temp. and Rate of Rise Thermal Sensor 135°F MIX-5251H Intelligent Low Profile High Temperature Thermal Sensor 190°F Intelligent Analog Bases B21OLP Intelligent Flanged Mounting Base £_ B224B1 Intelligent Isolator Base B224RB Intelligent Relay Base* B501 Intelligent Flangeless Mounting Base B501BH Intelligent Sounder Base B50IBHT Intelligent Temporal Tone Sounder Base Accessories RA-400Z Remote LED Annunciator Note: For Canadian models add suffix 'A' * When used with the M500X Fault Isolator Module, the number of relay bases between fault isolators is limited to 12. NOT TO BE USED FOR INSTALLATION PURPOSES. 4I,. MRc omo Canada . 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 Web page: http://www.mircom.com U.S.A. 60 Industrial Parkway Cheektowaga, New York 14227 Toll Free: (888) 660-4655 Fax Toll Free: (888)660-4113 Email: mail@mircom.com (..Fi. bU5 Roy. 5 . LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7270-1477:114 Page 1 of 1 Heat Detector Mircom Technologies Ltd, 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 Models MIX-5251P, -5251B, *.5251H (fixed temperature) and MIX-5251 RP, -5251RB (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. 'MIX-5251 P, -5251 B, 5251 RP, -5251 RB = 1350 F fixed temperature *Mlx..5251H = 1900 F fixed temperature In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical ratings, and UL Label. Listed as heat detectors for use with Models MIX-13501BH or MIX-1321OLP bases (CSFM Listing No. 7300-1477:116) and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. 7270-1209:193 *Rev. 06-09-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 9 Date Issued: JUNE 247 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS M4TEO, Program Coordinator Fire Engineering Division I 200 Series Mounting Base Options System Sensor mounting bases and kits provide a variety of ways to install detectors in any application. F Features Easy plug-in of detector to base SEMS screws, 12-24 AWG (14-24 for B224RB and 1322481) Multiple accessories for mounting flexibility UL 464 and UL 864 Compliant Sounder Bases Aaencv Listincis Model Listings B501 UI, ULQ FM, CSFM, MEA B21OLP UL, ULC, FM, CSFM, MEA B501 BH, B501BH-2, and B501BHT-2 UL, ULC, CSFM, MEA . 8501 BHT UL, ULC, CSFM B224RB UL, ULC, CSFM, MEA 6224B1 UL, ULC, FM, CSFM, MEA For ULC listed products, add "A"to the model number (e.g., B501 A). 200 Series detectors can be mounted in either flanged or flangeless bases depending on junction box selection (see junction box selection guide). Features. Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one form C contac: relay for control of auxiliary functions such as door closure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the faults removed. Sounder bases are available in temporal and non temporal pattern versions depending on whether the signal is to be used for evacuation purposes. Mounting. The recessed mounting kit provides the most aesthetically pleasing installation. Surface mounting boxes are available when flush mounting isn't possible. Whatever the installation challenge, System Sensor has the solution. Specifications, 200 Series Bases - - - -,-----"--.-"". ,.--- -, -- °—"--- Diameter 6501:4.1 in (104 mm); B21OLP, B224RB, B224B1: 6. . 1 (1 55 mm); B501BH, B501 BHT, B501 BH-2, B5O1BHT-2:6.0 in (152 mm) Wire Gauge B224Bl, 622466:24 to 14 AWG; B501 B21OLP, 6501 BH, B501 BHT, B501BH-2, 6501 BHT-2:24 to 12 AWG Temperature Range 32°F to 120°F (0°C to 49°C); B501 B2 IOLP: -4°F to 150°F (-20°C to 66°C) Humidity Range 10% to 93% RH non-condensing Operating Voltage 15 to 32 VDC (powered by SLC) External Supply Voltage 17 to 32 VDC Standby Ratings <500 pA maximum @ 24 VDC Standby Current 1.0 mA max. Set Time (8224R6 only) Short Delay: 55 to 90 msec SetTime 85018H/6501 BHT: 6 to 15 sec Long Delay: 6 to 9 sec B501BH-2/6501 BHT-2: 0.75 to 5.7 sec Reset Time (6224R8 only) 20 msec max. Maximum Ripple Voltage 10% of supply voltage Relay Characteristics 2 coil latching relay Sound Output Greater than 90 dBA measured in anechoic (622468 only) 1 Form C contact room at 10 feet, 24 v01ts85 dBA minimum in UL ULJCSA Rating: reverberant room - 0.9A@ 125 VAC Alarm Current 15 mAmax. 0.9A@ 110VDC Start-up Capacitance 200 p 3A@3OVDC 200 Series Junction Box Selection Guide Single -33 in 4 in 4 in 4 in 50 60 70 75 Model Gang Octagonal Octagonal Square Square' mm mm mm mm B501 No Yes No No Yes Yes Yes Yes No 13210LP Yes Yes . Yes Yes Yes No No No No 6224R6 No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes B501BH/13501BH-2 No No No Yes No No No No No B501BHT/65016HT-2 No No No Yes No No No No No with 3.0 in mud ring Note: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Ordering Information, 200 Series Bases Recessed Mounting Kit Product Overview Used with 6501, the RMK400 provides a simple installation solution 6501°' Flangeless Mounting Base B21OLP° Flanged Mounting Base in applications that demand a lower profile smoke detector. Kit is B501BH°' Standard Sounder Base suitable for use with 4 octagon, 50mm, and 60mm junction boxes ------ c... connected to flexible conduit. Junction boxes are not included in kit. 000 IbM Tp0I one DOUF iuer oose B501BH-2 Standard Sounder Base, UL 864 9th edition compliant 8501 BHT-2 TemporalTone Sounder Base, UL 864 9th edition compliant Drywall or suspended ceiling 6224RB°' Relay Base Standard junction boxes 6224B1°' Isolator Base Aesthetically pleasing RMK400 Recessed Mounting Kit 0 SMK400 Surface Mounting Kit (flangeless) SMBÔOO Surface _Mounting _Kit (flanged) 1`110 Retrofit flange for B501B/B524 200 Series Accessories U RA400Z°' Remote LED Annunciator M02-04-01 DetectorTest Magnet M02-09-00 Test Magnet with Telescoping handle XR28 Detector Removal Tool (T55-127-000 Included) XP-4 Extension Pole for XR2B (5 to 15 ft.) T55-127-000 Detector Removal Head BCK-200B Black Detector Kit WCK-200B White Detector Kit Add "A"to model number for ULC listed product (e.g., B501 A) T'\\ "LfSTEOfl.4 3825 Ohio Avenue. St. Charles, IL 60174 O2COsY5tflFSCOO Product specfcat on, subject to change without notice Visit uyssemsensor.cortr for ca,r,eotproductinfor,naFion, inducing the IatesFvnrionwi this daFauheeL SE,1.5ORO Phone: 800-SENSOR2 . Fax: 630-377-6495 A05-I020-004.9/05 . atast CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUUDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7300-1653:109 Page 1 of 1 CATEGORY Misc. Devices/Control Unit Accessories LISTEE System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, B404B, 1340413T, B406B, B501, B501B, 14506587-002, B501BH, B501BHT, B401BH, 131101-P, B110RLP, 13IIORLP750, BI 121-P, 131 141-P, 13II4LPBT, B116LPand B210LP detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicab codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division v. -PN Ii. Intelligent Addressable Interface Module (MIX-M502M) The MIX-M502M provides the same features as the MIX-M500M but also allows for the use of multiple, conventional 2-wire sthoke detectors in the circuit. This module requires a resettable signal power source. The MIX-M502M internally supervises the seperate power source. The red LED indicates when the module is activated. All two-wire detectors that are monitored must be UL/ULC compatible with the MIX-M502M module. -- --. INTELLIGENT ADDRESSABLE MODULES MIX-500 SERIES Mircom's intelligent module products are designed to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterflow switches, conventional smoke detectors and more. The modules are addressed with easy-to-use rotary code switches and mount in a standard 4" x4" x 2 1/8" junction box. Intelligent Addressable Dual Monitor Module (MIX-M500DM) The Intelligent Addressable Dual Monitor Module (MIX- M500DM) provides two independent 2-wire initiating device circuits at two separate, consecutive addresses. It is capable of monitoring two separate Class B (Style B) circuits simultaneously, making it ideal forwaterfiow and tamper switch monitoring. The MIX-500DM has a single activated red LED that is common to either circuit. Intelligent Addressable Mini-Monitor Module (MIX-M501 M) The lntelligentAddressable Mini Monitor Module provides an address for a group of UL/ULC Listed Normally Open (N.O.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class B (Style B) initiating circuit. M EA & @ 0 approved APPROVED S5434 S5434 7300-1477:113 427-91-6 3017996 (MIX-M5OIM, MIX-500R, (MIX-M500. M!X-M50IM) MI X-500S & MIX-M502M) 87-01-E 7300-1477:126 (MIX-M500R, MIX-M500S) (MIX-M500DM) 227-03-6 7300-1477:127 (MIX-M5000M) (MIX-M500M) CATALOG NUMBER IZtA' 1 0 Intelligent Addressable Monitor Module (MIX-M500M) The Intelligent Addressable Monitor Module (MIX- M500M) provides an address for a group of UL/ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-M500M has an activated red LED. J? U wJ NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discont i n u e m o d e l s . CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTiON OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUTLDNG MATERIALS LISTING PROGRAM LISTING SERVICE jg~k i LISTING No. 7300-1477:113 Page 1 of I CATEGORY:, Misc. Devices/Control Unit Accessories LISTEE: Mircom Technologies Ltd, *25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Models MIX-M50IM Monitor Module, and Models MIX-500R, MIX-500S, MIX-M500CH, and MIX-M502M Control Modules. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as accessories for use with separately listed compatible fire alarm control units. 9 XLF: 7300-1209:104 *Rev. 11-04-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: S Authorized By: JUNE 24, 2009 Listing Expires June 30, 2010 FRANCIS MA TEO, Program Coordinator Fire Engineering Division r.. Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert' Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTPA4ert The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. S When installing Advance products, first attach a universal mounting plate to a four-inch square, four-inch octagon or double-gang junction box, The two-wire mounting plate attaches to a single-gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Features Electrically compatible with existing SpectrAlert products Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Plug-in design Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110,115,135,150,177,185 Same mounting plate for wall- and ceiling-mount units Shorting sping on mounting plate for continuity check before installation -Tamper resi5tant construction Outdoor wall and ceiling products rated from -40°F to 151°F Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products NEMA 4X rated Compatible with MDL sync module Agency Listings SIGNALING <::::i~~> I'IIE $7;3125'1653.-188 125.1653:186 (nd°o' strobes) l653l87(ou1do ,trob6 (horr4s1ro6es, LISTED APPROVED approved chi,ne/,lrobes) ,, 7135-1653.189 3o,,, h6e,) 5401 3023572 M06452 -05-E 55512 53593 SpectrAlert Advance Specifications ArchitectlEngineer Spec,ficationsIll 1111 JJ - Il 11[— - IIL..... .uuill General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4x 1 'h-inch back box, 4-inch octagon back box or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 11/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance Circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit- Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75,30, 75,95,110, 11, 135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model -listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern.These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module . The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 4W16 X 411/16 x 21/a-inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. IiTTii TTIII 1T - - ITT:TIiTi Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature -40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12to18AWG Ceiling mount dimensions (including lens) 6.8 diameter x 2.5 high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61. x 4.7W x 2.5D (142 mm Lx 119 mm W x 64mm D) Horn dimensions 5.61x4.7Wx 1.3D(142 mm Lx 119mniWx 33 mm D) Wall-mount back box skirt dimensions (BBS-2, BBSW-2) 5.91 x 5.0W x 2.2'D (151 mm Lx 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions (BBSC-2, BBSCW-2) 7.1" diameter x 2.25 high (180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB) 5.71 x 5.1W x 2.00 (145 mm Lx 130 mm W x 51 mm Dl Ceiling-mount weatherproof back box dimensions (SA-W138C) 7.1 - diameter x 2.0" high (180 mm diameter x 51 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. 6050395-004 UL Current Draw Data 8-17.5 Volts 16-33 Volts 8717.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75° 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75°° NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High . 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40. 46 52 50 177 NA NA 281 251 185 NA NA 286 258 - 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 . 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 . Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 Ti 16-33 Volts 16--33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For 1< series products used at low temperatures, listed candela . - -- ratings must be reduced in accordance with this table. - . _ ___• 24VoltNominaI - . . ------ 8-17.5 16-33 Switch Volts Volts Reverberant Anechoic Position Sound Pattern d8 DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-temporal High 82 82 88 88 93 92 100 100 - 5 Non-temporal Medium 78 78 85 85 90 90 98 98 6 Non-temporal Low 75 75 81 81 88 84 96 92 P Coded High 82 82 88 88 93 92 101 101 8t- Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tsettings 7, 8, and 9 are not available on 2-wire horn/strobe. A05-0395-004 Listed Candela Candela rating at -40°F 15 Do not use below 32°F 30 15/75 75 --- 44 95 70 .110 110 115 115 135 135 150 150 177 177 185 1185 SpectrAlert Advance Dimensions Wall-mount horn/strobes Ceiling-mount horn/strobes '-7.1W 5.o5 Dia. II lI ___n F ( ckEjo " _ 1 '12 Wall back box skirt Ceiling hack box skirt SpectrAlert Advance Ordering Information Wall Horn/Strobes P2Rat 2-wire Horn/Strobe, Standard cd*, Red P4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor P4W 4-wire Horn/Strobe, Standard cd, White P4WH 4-wire Horn/Strobe, High cd,White Wall Strobes SRat Strobe, Standard cd, Red SRHt Strobe, High cd, Red SRK Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW Strobe, Standard cd, White SWHa Strobe, High cd,White Coiling Horn/Strobes PC2R 2-wire Horn/Strobe, Standard cd, Red PC2RH 2-wire Horn/Strobe, High cd, Red PC2RK° 2-wire Horn/Strobe, Standard cd, Red, Outdoor PC2RHK' 2-wire Horn/Strobe, Hiqh cd, Red, Outdoor Dia A . Wall weatherproof back box Ceiling weatherproof back box Ceiling Horn/Strobes (contd.) PC2 Wat 2-wire Horn/Strobe, Standard cd, White PC2WHat 2-wire Horn/Strobe, High cd,White PC4R 4-wire Horn/Strobe, Standard cd, Red PC4RH 4-wire Horn/Strobe, High cd, Red PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor PC4W 4-wire Horn/Strobe, Standard cd,White PC4WH 4-wire Horn/Strobe, High cd,White Ceiling Strobes SCR Strobe, Standard cd, Red WQWD SCRW Strobe, High cd, Red SCRK Strobe, Standard cd, Red, Outdoor SCRHK° Strobe, High cd, Red, Outdoor SCW Strobe, Standard cd, White SCWHf Strobe, High cd,White Horns HR Horn, Red HRK Horn, Red, Outdoor HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White P2RH 2-wire Horn/StrObe, High cd, Red P2RK° 2-wire Horn/Strobe, Standard cd, Red, Outdoor P211HK' 2-wire Horn/Strobe, High cd, Red, Outdoor P2Wa 2-wire Horn/Strobe, Standard cd, White P2WH 2-wire Horn/Strobe, High cd, White P4R 4-wire Horn/Strobe, Standard cd, Red P4RH 4-wire Horn/Strobe, High cd, Red P4RK' 4-wire Horn/Strobe, Standard cd, Red, Outdoor Notes: Add "-P"to model number for plain housing (noFlRE" marking on cover), e.g., P2R-P t Add "-SP"to model number for "FUEGO'marking on cover, e.g., P2R-SP. 4 "Standard cd refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd' refers to strobe s t h a t i n c l u d e 1 3 5 , 1 5 0 , 1 7 7 , a n d 1 8 5 candela settings. All outdoor units ending in "K" include a weatherproof back box. o Add "-R" to model number for weatherproof replacement device (no back box included). 0200 sy~emsem' aS'5TE14 3825 Ohio Avenue. St. Charles, IL 60174 ,SE1J.5ORa Phone: 800-SENSOR2. Fax: 630-377-6495 Current product inforwtiw, i'duding the latest versim of this data sheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:186 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 x 1185 Fax 630) 377-7245 Trish.Linhartsystemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCWCLRALERT* and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: • 8-17.5 or 16-33 VDC/FWR Candela: 15,15/75,30,75,95,110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 05-04-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator 0 Fire Engineering Division Technical Data Sheet Fire Alarm Cables 7Tjj7ftj 2833 West Chestnut Street Washington PA 15301 Toll Free: (800)245-4964 Fax: (724) 222-6420 www.wcstpenn-wpw.com PART NUMBER: 60990B DESCRIPTION: 16/2 Solid bare copper conductors, shielded with an overall jacket. NEC RATING: FPLP, NEC Article 760 APPROVALS: (UL) or (ETL)us Listed APPLICATION: Indoor within ducts, plenums, and other spaces used for environmental air for (Audio Circuits, Control Circuits, initiating Circuits, Notification Circuits) Construction Parameters: Conductor 16 AWG Bare Copper Stranding . Solid Insulation Material Polymer Alloy Insulation Thickness 0.010' Nom. Number of Conductors 2 Shield 100% Aluminum Polyester Foil Drain Stranded Tinned Copper Material Flexible Plenum .Jacket Jacket Thickness 0.015" Nom. Overall Cable Diameter 0.166" Nom. Approximate Cable Weight 29 Lbs/IM' Nom. Flame Rating NFPA- 262 Flame Test Electrical & Environmental Properties: Temperature Rating ..l0deg C to 60deg C Operating Voltage 300 V RMS Max.Capacitance Between Conductors @ 1 KHz 61 pf/ftNom. Capacitance Between Conductors to Shield @ 1 K}lz 110 pf/ft Nom. DC Resistance per Conductor @ 20deg C 4.1 Ohms/1M' Nom. Insulation Colors Black, Red Jacket Color Red RoHS Compliant Yes Mechanical Properties: Max. Recommended Pull Tension 76.4 lbs. Mm. Bend Radius (Install) 1.75" Specification Issue Date: 7/06 This document is the property of West Penn Wire. The information contained herein is considered Standard Lengths are 1000ft. Proprietary and not to be reproduced by any means The Jacket is sequentially footmarked. Without written consent of West Penn Wire The information presented here is, to the best of our knowledge, is true and accurate. However, since (td Environmnemit Precautions; Due to the nature of conditions of use are beyond our control, all PVC Compounds to become non-pliable when stored recommendations or suggestions are presented or handled in ambient temperatures of 32 deg. For without guarantee or responsibility on our part. We less, we recommend the following: disclaim all liability in connection with the use of "Prior to installation, condition the cable for at . best flex properties for case of installation." information contained herein or otherwise. least 24 hours at room temperature to provide the S Technical Data Sheet Fire Alarm Cables EST MY Of . ... 2833 West Chestnut Street Washington, PA 15301 Toll Free: (800) 245-4964 Fax: (724) 222-6420 www.westpenn-wpw.com ... aa PART NUMBER: 60993B . DESCRIPTION: 14/2 Solid bare copper conductors, unshielded with an overall jacket. NEC RATING: FPLP, NEC Article 760 APPROVALS: (UL) or (ETL)us Listed APPLICATION: Indoor within ducts, plenums, and other spaces used for environmental air for (Audio Circuits, Control Circuits, Initiating Circuits, Notification Circuits) Construction Parameters: Conductor 14 AWG Bare Copper Stranding Solid Insulation Material . Polymer Alloy Insulation Thickness 0.012" Nom. Number of Conductors 2 (1 Pair) Shield None Drain None Jacket Material Flexible Plenum Jacket Thickness - 0015" Nom. Overall Cable Diameter 0.191" Nom. Approximate Cable Weight 36 Lbs/IM' Nom. Flame Rating . . NFPA- 262 Flame Test Electrical & Environmental Properties: Temperature Rating -lOdeg C to 60deg C Operating Voltage 300 V RMS Max.Capacitance Between Conductors @ 1 Kl-Iz . 34 pf/ft Nom. DC Resistance per Conductor @ 20deg C 2.6 Ohms/lM' Nom. Insulation* Colors Black, Red Jacket Color Red RoHS Compliant Yes Mechanical Properties: Max. Recommended Pull Tension 99.4 lbs. Mm. Bend Radius (Install) 1.9" Specification Issue Date: 7/06 This document is the property of West Penn Wit-c. The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire Cold Tnvironttsent Precautions: Due to the nature of PVC Compounds to become non-pliable when stored or handled in ambient temperatures of 32 deg. F or less, we recommend the following: . "Prior to installation, condition the cable for at least 24 hours at room temperature to provide time best flex properties for ease of installation." Standard Lengths are l000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of out knowledge, is true and accurate. However, since conditions of use arc beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING — BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-0859:101 Page 1 of 1 CATEGORY: Cables-Fire Protective Signaling LISTEE: West Penn Wire, P0 Box 762, Washington PA 15301 Contact: Diane Kelley (724) 222-7060 FAX (724) 2291151* DESIGN: Types FPL and FPLP power limited fire protective signaling cable. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type, NEC rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. S *Rev. 05-23-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-31 FIRE ALARM SYSTEM FILE COPYFCORD OF COMPLETION r_/P~ % Name of protected property: — Address: Representative of protected property (name/phone): Authority having jurisdiction: Address/telephone number: - Organization narne/ohone Representative namEl phone Installer: 1 —'i9$ 't Supplier: 7,,j'r-J. /-- r.-, / ', J ,( ' Service organization: organtzation:'r.,c,J ig4;. /_4.4-.r-c fs p, Location of record (as-built) drawings: Location of operation and maintenance manuals: Location of test reports: A contract for test and inspection in accordance with NFPA s t a n d a r d ( s ) ContracLNo(s): Effective date: System Software 9perating system (executive) software revision level(s): Site-pecific software revision date: Revision completed by: (nan1) 1. Type(s) of System or Service' Expiration date: NFPA 72, Chapter 6— Local If alarm is transmitted to location(s) off premises; list where received: NFPA 72, Chapter 8 - Remote Station Telephone numbers of organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are re-transmitted to public fire service communi c a t i o n s c e n t e r s o r o t h e r s , i n d i c a t e l o c a t i o n a n d telephone numbers of the organization receiving alarm: Indicate how alarm is re-transmitted: 14kkk 74 Chapter 8 - Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are re-transmitted to public fire service communicatio n s c e n t e r s o r o t h e r s , i n d i c a t e l o telephone numbers of the organization receiving alarm: Indicate how alarm is transmitted: NFPA 72, Chapter 8 - Central Station Prime contractor: S / J-,. Central station location: ' tion and (NFPA 72, 1 of 4) 2002 Edition H:WP61 \ FORMS \ NFPA 72 COMPLETION it qçj— Signed: Organiz FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-32 Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex ______One-way radio Digital alarm communicator Two-way radio Others Mea7ransmission of alarms to the public file service communications center: System location: -- NFPA 72, Chapter 9 — Auxiliary Indicate type of connection: Local energy Shunt Parallel telephone Location of telephone number for receipt of signals: 2. Record of System Installation Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This tem has been installed in accordance with the NFPA standards as shown below, was inspected by -€ t on /) —O -k--- includes the devices shown in 5 and 6, and has beenin service since -.7-V-40 9 NFPA 72, Chapter0l ) (1.9 c:i.4'1) 2 9 6ji) ) (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached All operational features and functions of this system were tested by date ) ? 1 -1 0 'j and found to be operating in accordance with the requirements of: NFPA 72, hapterO) & & & 9 ) (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions _______ Other (pecify): Signed: .I3AA4 t2 Organization: I Date: / -- f Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA72, Table 6.6.1): Quantity: _ Style: 4' Class: C Alarm-initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5): Quantity: Style: Class: MANUAL Manual stations Non-coded Transmitters Coded Addressable Combination manual fire alarm and guard's tour coded stations (NFPA 72, 2 of 4) 2002 Edition H:WP6 1 \ FORMS \ NFPA 72 COMPLETION 2 FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 AUTOMATIC Coverage: Complete Partial Selective Nonrequired -- Smoke detectors 7 Ion Photo Duct detectors Ion Photo Heat detectors I FT RR - Sprinkler water-flow indicators: Transmitters The alarm verification feature is disabled seconds. Other (list): - Addressable 7 Addressable ?' FT/RR ______ RC Addressable I Non-coded Coded Addressable L or enabled changed from seconds to 6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUA1D 'S TOUR Coded stations Non-coded stations ______ Compulsory guard's tour system comprised of transmitter stations and intermediate stations. NOTE: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour . SPRINKLER SYSTEM Check if provided Valve supervisory switches Building temperature points - Site Water temperature points Site water supply level points Eleôtric fire pump: - Fire pump power (1) Fire pump running - Phase reversal Engine-Driven Fire Pump: Selector in auto position Engine or control panel trouble Fire pump running Engine-Driven Generator: Selector in auto position Control panel trouble Transfer switches - Engine running Other supervisory function(s) (specify): Annunciator(s) Number: Type: Location: Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 - Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: Quantity and the class of notification appliance circuits connected to system (see NPFA72, T a b l e 6 . 7 ) : Quantity: (NFPA 72, 3 of 4) 2002 Edition H:WP61 \ FORMS \ NFPA 72 COMPLETION FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-34 Types and quantities of notification appliances installed: Bells With Visible Speakers With Visible Horns With Visible Chimes With Visible Other: With Visible (f Visible appliances without audible: 9. System Power Supplies Fire Alarm Control Panel: Nominal voltage: I -2 Current rating: / A Over-current protection: Type: 13 Current Rating: ? 4 Location: m /n Secondary (standby): Storage battery: Amp-hour rating• Calculated capacity to drive system, in hours: )!!k Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency system used as backup to primary power supply: Emergency System described in NFPA 70, Article 700: 10. Comments: Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: C )b /• [a o I (signed) for alarm service company (title) (date) (signed) for central station (title) (date) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): representative olthc authority (NFPA 72,4 o(4) 2002 Edition H:WP6 I \ FORMS \ NFPA 72 COMPLETION 4