Loading...
HomeMy WebLinkAbout2141 PALOMAR AIRPORT RD; 160; AS130209; Permit12/28/2020 AS1 30209 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS130209 2141 PALOMAR Job Address: Status: ISSUED AIRPORT RD Permit Type: SPRINK Applied 11/26/2013 Parcel No: 2130701600 Approved: 12/10/2013 Lot #: 0 Reference No.: Issued: 12/10/2013 PC #: Inspector: Project Title: SPEC STE 160 TI: REMOVE EXISTING 1" LINES AND REPLACE WITH NEW 1" LINES TO CENTER UPRIGHT PROTECTION W/IN STRUCTURAL BAYS. SEE FLOOR PLAN FOR NEW SPRINKLER LAYOUT. Applicant: Owner: REALTY ASSOCIATES FUND VII L P C/O TA ASSOCIATES REALTY 1301 DOVE ST #860 NEWPORT BEACH CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 268 0 268 0 1/1 TE'DrZiecinc. MATERIAL DATA SUBMITTAL Spec Suite * 160 2141 Palomar Airport Road Carlsbad, CA 92011 Page Product Description 1-2 Sprinkler Piping 3-10 Sprinkler Piping 11-12 Sprinkler Piping 13-19 Sprinkler 20 Pipe Hangers & Supports 21 Pipe Hangers & Supports 22 Pipe Hangers & Supports 23 Pipe Hangers & Supports 24-26 Pipe Hangers & Supports ALLIED Dyna Thread Pipe TYCO Ductile Iron Fittings TYCO Mechanical Tee TYCO TY-FRB Q.R. SSP & SSU AFCON Fig 100 Beam Clamp AFCON Fig 162 Retaining Strap AFCON Fig 300 Ring AFCON Fig 655 All Thread Rod HILTI HDI Drop in Anchor Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, Ca 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpjohncgmail.com A5130209 DynamThreade S Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. S Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (9 <S> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40fDyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA- 13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Speci fications NPS Nominal I.D. WI. WI. (1120 Filled) Pcs/ Wt/Lift (21') WVLifI (24') Wt/Lift (25') In; mm In; mm Lbs/Ff;Kg/m Lbs/Ft;Kglm Lift Lbs;Kg Lbs;Kg Lbs;Kg 1" 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 1W 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1'!? 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 16100 S. Lathrop • Harvey, IL 60426 tqca '/Flow Control died 11350 Norcom Rd. • Philadelphia, PA 19154 TUBE& CONDUIT 2525 N. 27th Ave. Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 S3-3 Submittal Data Sheet Dyna-Thread* Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Stamp Here is Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40fDyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Specifications NPS Nominal I.D. WI. WI. (1120 Filled) Pcs/ WI/LIlt (21') WI/Lift (241 WI/tilt (25' In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs: Kg Lbs; Kg Lbs; Kg 1 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 1W 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 11/2' 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2' 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Fin are the same product as (j) .> @are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BIT is manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 2 S3-4 S tqC0 Fire & Building I)Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Pipe Fittings NPT Threaded, Ductile Iron General Description The Tycoe Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17.2 bar) Figure 719 Plug: 250 psi (17,2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI B1.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable JANUARY, 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- oress or implied, including warranties of merchantability and fitness for a oarticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. registered trademark of E. I. du Pont de ('Tj"\ Nemours and Company or its affiliates. TFP171"'1 Page 2of1O TFP1710 fl Nominal Pipe Figure 813 Size ANSI A Approx. Inches Inches Weight Part ON (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 DN15 (28,7) (0,09) 3/4 1.31 0.33 86781 DN20 (33,3) (0,15) 1 1.50 0,48 86280 0N25 (38,1) (0,21) 1-1/4 1.75 0.73 88281 0N32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2.25 1.55 86283 DN50 (57,1) (0,70) _______ 2-1/2 2.69 2.70 T 86782 DN65 (68,3) (1,22) 0 L~.B BT A FIGURE 811 FIGURE 813 900 ELBOW 450 ELBOW TABLE 1 NOMINAL DIMENSIONS FIGURES 811 & 813 Figure 811 B Approx. A B Inches Weight Part inches inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19,0) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0,29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (302) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0,79) (42,7) (23,9) 1.56 3.28 86204 1.94 1.00 (39,6) (1,49) (49,3) (25,4) TFPI7IO Page 3 of 10 62 FIGURE 812 90 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Weight Part Inches Inches Inches Inches Inches Lbs. ON (mm) (mm) (mm) (mm) Number (kg) 3/4 x 1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20x15 (30,2) (302) (16,0) (16,0) (0,15) 1 x112 1.25 1.38 0.56 0.81 0.44 86210 DN25 x 15 (31,8) (35,1) (14,2) (20,6) (0,20) 1 x3/4 1.38 1.44 0.69 0.88 0.53 86211 DN25 x 20 (35,1) (36,6) (17,5) (22,4) (0,24) 1-114x 1/2 1.31 1.50 0.63 0.94 0.64 86212 DN32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-1/4x3/4 1.44 1.63 0.75 1.06 0.75 86213 DN32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 1-1/4x1 1.56 1.68 0.88 1.00 0.77 86214 DN32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35) 1-1/2x3/4 1.50 1.75 0.75 1.19 0.95 86221 0N40 x 20 (38,1) (44,4) (19,0) (30,2) (0,43) 1-1/2 x 1 1.63 1.81 0.88 1.13 0.99 86215 DN40x25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-112x1-114 1.81 1.88 1.13 1.19 1.14 86216 DN40 x 32 (46,0) (47,8) (26,7) (30,2) (0,52) 2x314 1.63 1.94 0.88 1.38 1.39 86217 DN50x20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 DN50x25 (44,4) (523) (50,8) (33,3) (0,72) 2 x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50x40 (50,8) (55,6) (31,8) (36,6) (0,76) 2-112x2 2.38 2.63 1.25 1.88 3.01 86262 DN65 x 50 (60,5) (66,8) (31,8) (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 S TFPI7I0 Page 5of 10 S N"N t FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 Figure 814 Figure 818 B Approx. A B Inches Weight Lbs. Part Number Inches Inches (mm) (kg) (mm) (mm) 0.56 0.33 86340 1.38 0.31 (14,2) (0,15) (35,1) (7,9) 0.75 0.50 86341 1.63 0.56 (19,0) (0,23) (41,4) (14,0) 0.81 0.85 86230 1.75 0.38 (20,6) (0,38) (44,4) (9,7) 1.06 1.30 86231 2.00 0.56 (26,9) (0,59)(50,8) (14,0) 1.19 1.63 86232 2.19 0.75 (30,2) (0,74) (5516) (19,0) 1.50 2.63 86233 2.63 1.13 (38,1) (1,19) (66,8) (28,7) 1.56 4.55 86234 3.00 0.75 (39,6) (206) (76,2) (19,0) Nominal Pipe Size A Approx. ANSI Inches ON Inches Weight Lbs. Part Number (mm) (kg) 1/2 1.13 0.18 72779 DN15 (28,7) (0,08) 3/4 1.31 0.26 72778 DN20 (33,3) (0,11) 1 1.50 0.44 72755 DN25 (38,1) (0,20) 1-1/4 1.75 0.54 72754 DN32 (44,4) (0,24) 1-1/2 1.94 0.71 72753 DN40 (49,3) (0,32) 2 2.25 1.15 72752 DN50 (57,1) (0,52) 2-1/2 2.69 2.29 72758 DN65 (68,3) (1,04) 0 TFPI7I0 Page 6of 10 0 Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 A B C D E F Approx. ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part DN (mm) (mm) (mm) (mm) (mm) (mm) Lbs. Number (kg) 1-1/2x1-1/4x112 1.44 1.31 1.69 0.69 0.63 1.13 1.03 DN40x32x15 (36,6) (33,3) (42,9) (17,5) (16,0) (28,7) (0,47) 86257 1-1/2x1-1/4x3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 DN40x32x20 (38,1) (36.6) (44,5) (190) (19,0) (30,1) (050) 86258 1-1/2x 1-114x 1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 DN40x32x25 (41.4) (39,7) (46,0) (22,4) (22,4) (28.7) (0,59) 86259 1-112x1-114x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 DN40x32x50 (55,6) (54,1) (50,8) (36,6) (36,6) (57,1) (0,88) 86260 1-112x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 DN40x40x15 (36.6) (36,6) (42,9) (17.5) (17,5) (28.7) (0,52) 86261 1-112 x 1-1/2 x 3/4 1.50 1.50 1.75 0.75 0.75 1.19 1.23 DN40x40x20 (38,1) (38,1) (44,4) (19,0) (19.0) (30,1) (0,56) 86262 1-1/2x1-1/2x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 DN40x40x25 (41,2) (41,2) (46.0) (22,4) (22,4) (28,7) (0,62) 86263 1-112x1-1/2x1-114 1.81 1.81 1.88 1.06 1.06 1.19 1.50 DN40x40x32 (46,0) (46,0) (47,6) (27,0) (27,0) (30,1) (0,68) 86264 1-112x1-1/2x2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 DN40 x 40 x 50 (55,5) (55,5) (50,8) (36,6) (36,6) (31,7) (0,91) 86265 2 x 1 x 2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 0N50 x 25 x 50 (57,2) (50,8) (57,2) (38,1) (33,3) (38,1) (0,99) 86266 2x1-1/4x2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 DN50x32x50 (57,2) (54,1) (57,2) (38,1) (36,6) (38,1) (1,05) 86267 2x1-1/2x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 DN50x40x15 (38,1) (36,6) (47,8) (19.0) (17,5) (33,3) (0,68) 86268 2x1-1/2x314 1.63 1.50 1.94 0.88 0.75 1.38 1.61 DN50x40x20 (41,4) (38,1) (49,3) (22.4) (19,0) (35,0) (0,73) 86269 2x1-1/2x1 1.75 1.63 2.00 1.00 0.88 1.31 1.65 DN50x40x25 (44,5) (41,4) (50,8) (25.4) (22,4) (33,3) (0,75) 86270 2x1-1/2x1-1/2 2.06 1.94 2.19 1.31 1.19 1.44 2.03 DN50 x 40 x 40 (52.4) (49,2) (55,5) (33,3) (30,2) (36,6) (0,92) 86272 2x1-1/2x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 DN50 x 40 x 50 (57,1) (55,5) (63.5) (38,1) (36,6) (38,1) (1.07) 86273 2x2x1/2 1.50 1.50 1.88 0.75 0.75 1.31 1.50 DN50x50x15 (38,1) (38,1) (47,8) (19,0) (19,0) (33,3) (0,68) 86222 2x2x3/4 1.63 1.63 1.94 0.88 0.88 1.38 1.67 DN50x50x20 (41,4) (41,4) 1 (49.3) (22,4) (22,4) (35,0) (0,76) 86223 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 DNSO x 50 x 25 (44,5) (44,5) (50.8) (25,4) (25,4) (33,3) (0,86) 86224 2x2x1-114 1,88 1.88 2.13 1.13 1.13 1.44 2.05 DNSO x 50 x 32 (47,8) (47,8) (54.1) (28.7) (28.7) (36,6) (0,93) 86225 2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 DN50x50x40 (50.8) (50,8) (55,6) (31,8) (31,8) (38,1) (0,95) 86226 2x2x2-112 2.63 2.38 1.Th 1.88 1.44 3.67 DN50 x 50 x 65 (66,8) (60,5) (44,5) (47,8) (36,6) (1,66) 86227 2-1/2x2x314 E44 1.63 2.31 0.63 0.88 1.75 2.22 DN65 x 50 x 20 (41,4) (58,7) (15.9) (22,4) (44,5) (1,01) 86274 TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 S Page 8 of 10 TFPI7IO I!A!I1 ii a I irniui FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Figure 820 Figure 830 Figure 719 Size ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part DN (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) (kg) 1/2 088 0.15 72776 1.88 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0,06) (47,8) (20,6) (0,21) (23,9) (0,04) 3/4 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 0N20 (25,4) (0,10) (50,8) (23,9) (0,30) (28,7) (0,08) 1 1.18 0.33 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 0N25 (30,0) (0,15) (55,6) (20,6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72756 2.50 1.06 1.54 86277 1.38 0.50 86295 lN32 (33,3) (0,24) (63,5) (26,9) (0,70) (35,1) (0,23) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 86296 DN40 (35,1) (0,31) (66,8) (30,2) (0,92) (36,6) (0,32) 2 1.50 0.96 72823 3.13 1.63 3.15 86279 1.50 0.90 86297 0N50 (38,1) (0,43) (79,5) (41,4) (1,43) (38,1) (0141) 2-1/2 1.75 1.80 72825 - - - - - - - 0N65 (44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 9 TFPI7IO Page 9 of 10 r-----'_ii FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI Inches Inches Weight Part Inches Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - - 0N15 x 15 (38,1) (0,09) 1/2 x 1/2 2.00 0.27 72980 - - - - - - - DN15 x 15 (50,8) (0,12) 3/4 x 3/4 1.50 0.22 72981 - - - - - - - DN20 x 20 (38,1) (0,10) 3/4 x 3/4 2.00 0.31 73982 - - - - - - - DN20 x 20 (50,8) (0,14) 3/4 x 1/2 1.75 0.69 0.38 86772 DN20 x 15 - - - - (43,2) (17,5) (0,17) 1 x 1/2 1.06 0.22 72726 1.69 0.50 0.38 86228 0N25 x 15 - - - (26,9) (0,10) (42,9) (12,7) (0,17) 1 x3/4 1.06 0.18 72762 1.75 0.50 0.53 86229 0N25 x 20 - (26,9) (0,08) (43.2) (12,7) (0,24) 1-1/4x1 1.19 0.31 DN32x25 - - - (30,2) (0,14) 1-1/2x1 1.25 0.53 72757 - - - - DN40 x 25 - - (31,7) (0,24) 1-1/2x1-1/4 1.25 0.35 72764 - - - DN40 x 32 - - - (31,7) (0,10) 2x1 1.38 0.75 72759 - - - - DN50x25 - - - (35,1) (0,34) 2x1-1/4 1.38 0.69 72761 - - - - DN50 x 32 - - - (35,1) (0,31) 2 x 1-1/2 1.38 0.62 72775 - - - - 0N50 x 40 - - (35,1) (0,28) TABLE 7 NOMINAL DIMENSIONS FIGURE 825, 827 & 816 0 tqZa Fire & Building IlProducts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap [I: General Description & UL b See Fire Protection Submittal Sheet for FM Pressure Rating and Listing/Approval Information The Figure40-5 Strap is an economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARifiNG The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document as well as with theapplicablestandards of the National Fire Protection Association, in addition to the standards otanyotherauthorities ha ving jurisdiction. Failure to do so mayimpair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical fFft Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing / Approval information. Page 1 of 2 Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM 8-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade 'E" EPOM green color code. (See Data Sheet 1FP1895 for aid in selecting proper gasket) When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade "E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their lire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified Inspection Service. September 2004 Limited Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and property installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownershipwith Tyco Fire Products orfor products and components which have been subject to misuse, improperinstallation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any ottierAuthorities Having Jurisdiction. Materials found byTyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit,anyotherobligationinconnectionwith the sale of products or parts of products. Tyco Fire Productsshallnotberesponsibleforsprinklersystem designerrorsorinaccurateorincompleteinformation supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTtALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCO FIREPRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALLIYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. (B TFPI72O Pipe Nominal Dimensions Hole Net Size Size Wt. A B C D Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 2.00 1.50 3.50 1.20 134e 0.84 50.8 38.1 88.9 30.5 30.2 0.4 11/40 x 3/0 2.00 1.50 3.50 1.20 1/16 0.88 50.8 38.1 88.9 30.5 30.2 0.4 11/40 i 2.31 1.66 3.50 1.20 1/16 1.13 58.7 42.7 88.9 30.5 30.2 1 0.5 11/20 X 1/20 2.12 1.62 3.50 1.32 1/is 0.84 53.8 41.1 88.9 1 33.5 30.2 0.4 11/2 X3/4° 2.12 1.62 3.50 1.32 i/16 0.88 53.8 41.1 88.9 33.5 30.2 0.4 11/20 X i 2.43 1.80 3.50 1.32 i/I6 1.13 61.7 45.7 88.9 33.5 30.2 1 0.5 2X 1I2 2.36 1.86 3.74 1.55 13'i 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2' x 3/4k 2.36 1.86 3.74 1.55 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2"x 1' 2.67 2.04 3.74 1.55 1/18 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/20 X 1/20 2.61 2.11 4.25 1.80 l/i 0.90 66.3 53.6 1 108.0 45.7 30.2 0.4 21/20 X3140 2.61 2.11 4.25 1.80 1/16 0.99 ________ 66.3 53.6 108.0 45.7 30.2 0.4 21/2' x 2.92 2.29 4.25 1.80 1/i 1.21 74.2 58.2 108.0 45.7 1 30.2 1 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 11/4"X 1' 8 11/2'X 1" 6 2"x 1 6 21/2"x 1' 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Ii Page 2 of 2 TFP1 720 Figure 40-5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. 12 General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure 1311" 0 that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (I1-1.1000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. . Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. tYCJJ Fire & Building IlProducts Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series TYIFRB - 2.8,4.2,56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco° Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet 1FP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. AUGUST, 2007 Model/Sprinkler Identification Numbers TVII3I - Upright 2.8K, 1/2"NPT 1Y1231 - Pendent 2.81K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT 1Y2231 - Pendent 4.21K. 1I2"NPT TY3131 - Upright 5.61K, 1/2"NPT 1Y3231 - Pendent 5.61K. 112"NPT 1Y4131 - Upright 8.01K, 3/4"NPT 1Y4231 - Pendent 8.0K, 314"NPT TY4831- Upright 8.01K, 1/2"NPT TY4931- Pendent 8.0K, 1/2"NPT (B TFPI 71 TFPI7I Page 3 of 10 7/16(1l.1 mm) STYLE 100r2( RECESSED ESCUTCHEON 2-7/8" (73,0 mm) DIA. -I PENDENT RECESSED PENDENT - Frame 3- Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5: Compression Screw DEFLECTOR ;rN(OMINAL " 6 mm)2-3/16" (55,6mm) 3 -IN 1/2° NPT UPRIGHT CROSS SECTION * Temperature rating is Indicated on deflector or adjacent t orifice seat on frame. ESCUTCHEON PLATE SEATING SURFACE NPT 2-3/16" - (55,6 mm) 1-1/2 (38,11 mm) SSP DEFLECTOR * FIGURE 3 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2' (12,7 mm) PLATE SEATING NOMINAL SURFACE MAKE-IN NPT 2-5/16" _ (58, mm) I 1-9/16" (39,7 mm) SSP DEFLECTOR * 2-7/8" PENDENT RECE STYLE 30 0r40 RECESSED SSU* ESCUTCHEON DEFLECTOR 112" 5 PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembl..-' 5 - Compression orifice seat on frame. Screw FIGURE 4 ..-QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4 131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT Page 4oflO TFP171 7/16"(11,1 mm) NOMINAL SSU 1/2 MAKE-IN DEFLECTOR N PT 2-1/4" 2-3/16" (57,2 mm) ________ (55,6 4 \ / 1-9/16" _________ 2 (39,7 mm) FLATS WRENCH 3 SP* EFLECTOR CROSS PE NT UPRIGHT SECTION - Frame 3 - Sealing 4 ulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to Assembly 6 Compression orifice seat on frame. Screw iII°fl FIGURE 5 UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/bar112) K = 4.2 GPM/psi1/2 (60,5 LPM/barl'2) K = 5.6 GPM/psil'2 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/barl'2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K I TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE"' 1POLYESTER LEAD COATED 5.6 1/2* PENDENT (TY3231) and 135°F/57°C 155°F/68°C Orange Red 1,2,3,4,5,6,7 12, 3,5 175°F/79°C Yellow (TY3131) UPRIGHT I 200°F/93°C Green 286°F/141°C Blue NPT PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1,2,4,5 N/A RECESSED155°F/68°C Red I 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (1Y3231)** Figure 11 135°F/57°C Orange 1,2,3,4,5 N/A 155°F168°C Red 175°F179°C Yellow 200°F/93°C Green - 8.0 3,4,, PENDENT (TY4231) and UPRIGHT (TY4131) 135"F/57°C Orange 1, 2, 3,4,5, 6, 7 1, 2, 5 155"F/68°C Red 175°F179°C Yellow 200"F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY4231)° Figure 12 135°F/57°C Green 1,2,4,5 N/A 155°F/68°C Orange 175°F/79°C Red 200°F193°C Yellow RECESSED PENDENT (TY4231) Figure 13 135°F/57°C Orange 1,2, 3, 4,5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green - 8.0 1/2" NPT PENDENT (1Y4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1,2,4,5,6 1, 2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use In Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City or New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. ** installed with Style 20 (1/2" NPT) or Style 30 (3/4° NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND &O K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME I WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 112" RECESSED PENDENT NPT (1Y323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 OR I UPRIGHT (TY3131) 1/2k 175 PSI (12,1 BAR) L RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (1Y4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) RECESSED PENDENT NPT (fl'4231) N/A 8.0 PENDENT(TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories,lnc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE 10 Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135F/57C to 3/32 inch (2,4 mm) for the 286F/141C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed S S TFPI7I 2-718" DIA. - 5/8±1/4" (73,0 mm) I 3/4"(19,1 mm (15,9±6,4 mm) 2-1/4" DIA. 1/4~(6 ~ A FACE OF , '• MTING SPRINKLER PLTE FITTING I (3,2 mm) I. MOUNTING SURFACE SERIES 1-1/4"(31,8 mm) I CLOSURE TY-FRB 3/4"(19,1 mm) FIGURE 10 RIES TY-FRB RECESSED PENDENT WIT TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,91-6,4 mm) 2-1/4"IDIA. •___.- 114"(6,4 m (57,2 mm) FACE OF MOU INC SPRINKLER ATE FITTING / 1/8" I (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33.3J.M) TY-FRB 13/16'(20.6 mm) FIGURE 12 S IES TY.FRB RECESSED PENDENT WIT 0-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 - 2-7/8' DIA. (73,0 mm) 1/2±1/8" 1/2"(12,7 m (1 2,7±3,2 mm) - 2-1/4" OIA 1/4" (6,4 m) FACE OF (57.2 mm) 71 MO TING SPRINKLER PLATE )5.6 Iz (3,2 mm) SERIES 1-114"(31,8 mm) TY.FRB 1" (25,4 mm) FIGURE 11 -FRB RECESSED PENDENT E 1/2 INCH TOTAL ADJUSTMENT RECESSED ESCUTCHEON -FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 1/2±1/8" (73.0 mm) 1/2"(12,7 mm) (12,7±3.2 mm) 2-1/4" OIA. 1/4" (6,4 (57,2 mm) FACE OF MO TING SPRINKLER LATE FITTING / 1/8" I - (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1.5/16" (33,3 mm) TYFR8 1-1116'(27.0 mm) FIGURE 13 RIES TY.FRB RECESSED PENDENT WIT TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. 8 Page 10 of 10 TFPI 71 P/N 57- XXX MODEL/SIN 330 2.8K UPRIGHT (1/2"NPT) TYII31 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2'NPT) 1Y2131 341 4.2K PENDENT (1/2"NPT) 1Y2231 1370 5.6K UPRIGHT (112NPT) TY3131 LEL 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (314"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (112'NPT) TY4831* 361 8.0K PENDENT (1/2'NPT) TY4931* I I I SPRINKLER 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL90IO)* 9 CHROME PLATED 7 LEAD COATED I 135 155 175 200 286 RATING TEMPERATUI 135*F/57*C 155°F/68°C 175°FI79C 2000F/93*C 286°F/141°C * Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS S Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shalt TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. cress or imoilea. inciva;na warranties This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table 0). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, PIN 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, PIN 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 100 BEAM CLAMP SMALL MOUTH <9> C®US SIZE - 3/8 and 1/2" rod. MATERIAL - Ductile iron with hardened cup point set screw and jam nut. FINISH - Plain, Electro-Galvanized and H.D.G. and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL- Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H-1 71 E Type 19 and 23 and Manufactures Standardization Society ANSI/MSS-SP-58 Type 19 and 23. FUNCTION -To hang from steel beam with flange thickness ofi ess than 3/4'. INSTALLATION - Per NFPA#13 - 3/8 rod will support 1/2' thru 4' pipe and 1/2' rod 5" thru 8' pipe. Install in accordance with ANSI/MSS-SP-69. Torque - 3/8=60 inch pounds. Torque - 1/2= 125 inch pounds. In the absence of a torque wrench, the set screw should be finger tightened and then an additional 1/3 turn applied to the set screw. FEATURES * Maintains CONSTANT HANGER CENTER-LINE, with set screw up or down. * Flat throat back prevents twisting during installation. ORDERING - Part #, rod size and finish. Index 5/01 162 UNIVERSAL - RETAINING STRAP Nut optional, if insufficient rod dimension SIZE- One size fits both 3/8" and 1/2" rod or set screw. Available lengths 4" and longer. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING - UL in US and CANADA. PATENT - No. 5,897,088 FUNCTION - To offer more secure fastening of Beam Clamp to beam when danger of movement might be expected. INSTALLATION - Install tight to structure and component parts Minimum return on strap: 1" FEATURES * Fast installation for new construction or retrofit. * Requires no hanger disassembly to install. IMPORTANT NOTE "No Nut Is Required" When installed tight to structure and component parts per good installation practice (See drawings provided) ORDERING - Part # and overall length. Index 12/00 IMPERIAL MAX REC. LOAD LBS. METRIC PIPE PIPE ROD 1/2 3/8 400 10 —;:;-- 3/8 400 20 10 1 3/8 0° 25 10 1 1/4 3/8 400 32 10 11/2 3/8 400 40 10 2 3/8 400 so 10 21/2 3/8 600 65 10 3 600 80 io 3 1/2 600 10 4 1000 100 10 1250 125 12 6 18 5 1250 150 12 1250 Order Part #300m Note: 1/2' Ring Hanger not <FM> approved ( D 300 RING HANGER 1 thru 4 inch pipe 1/2 and 3/4 Inch pipe 5 thru 8 inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mil. Galvanized to G-90 specification. FINISH - Mil. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H-1 71 (Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - 1 thru 4 inch: *Offset edge for EASY pipe insertion. 1 thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru 3 inch: * UL listed to accept AFCON #310 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index 02/01 [I C SD 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in linch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. 2/00 ( D Listinas/Aoorovals City of Los Angeles Research Report No. 23709 (HDI Only)_ FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems (3/8 - 3/4') (HDI and HDI-L) UL (Underwriters Laboratories) UL 203 Pipe Hanger Equipment for Fire Protection Services (3/8 - 3/4) A:IHDI & HD Drop Anchor TT 4.3.8.1 Product Description The Hilti HDI/HDl-L Drop-In anchor is an • Intelligent expansion section internally threaded, flush mounted adapts to the base material and expansion anchor for use in concrete. reduces number of hammer blows up to 50% (HDI-L) Product Features Guide Specifications 4,3.8.1 Product Description is 4.3.8.2 Material Specifications 4.3.8.3 Technical Data 4.3.8.4 Installation Instructions 4.3.8.5 Ordering Information Anchor, setting tool and Hilti drill bit form a matched tolerance system to provide reliable fastenings Allows shallow embedment without sacrificing performance Lip provides flush installation, consistent anchor depth, and easy rod alignment (HDI-L) Lip allows accurate flush surface setting, independent of hole depth (HDI-L) Ideal for repetitive fastenings with threaded rods of equal length Expansion Anchor Expansion anchors shall be flush or shell type and zinc plated in accordance with ASTM B 633, SC 1, Type III. Anchors shall be Hilti HDI/HDI-L anchors as supplied by Hilti. Installation Install shell or flush type anchors in holes drilled with Hilti carbide tipped drill bits. Install anchors as per manufacturer's recommendations. 4.3.8.2 Material Specifications HDI/HDI-L, 1/4', 3/8", 1/2', and HDI 5/8" and 3/4" are manufactured from mild carbon steel which is plated with a zinc finish for corrosion protection in accordance with ASTM B 633, SC 1, Type III HDI Stainless Steel material meets the requirements of AlSI 303 4.3.8.3 Technical Data HDI/HDI-L Specification Table Anchor HDl/HDI-L HDI 1/4 318 1/2 5/8 3/4 Size in. Details (mm) (6.4) (9.5) (12.7) (15.9) (19.1) dbit Nominal Bit diameter In. 3/8 1/2 5/8 27/32 1 h 0 Std. depth of embed. in. 1 1-9/16 2 2-9/16 3-3/16 Anchor length (mm) (25) (40) (51) (65) (81) h1 Hole depth Useable thread in. 7/16 5/8 11/16 7/8 1-3/8 length (mm) (11) (15) (17) (22) (34) Threads per inch 20 16 13 11 10 h mm. base material in. 3 3-1/8 4 5-1/8 6-3/8 thickness (mm) (76) (79) (102) (130) (162) Tmax max tightening ft-lb 4 11 22 37 80 torque (Nm) (5.4) (14.9) (29.8) (50.2) (108.5) Combined Shear and Tension Loading . IN, \5/3 fVd \513 7j + , 1.0 (Ref. Section 4.1.2.7) 362 HHLI, Inc. (US) 1-800-879-8000 1 www.us.hUtl.com I an espafiol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Product Technical Guide 2008 fl HDI & HDI-L Drop-In Anchor 4.3.8 Carbon Steel HDI Allowable Loads in Concrete Anchor size 2000 psi (13,8 MPa) 4000 psi (27.6 MPa) 6000 psi (41.4 MPa) in.(mni) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) HDI FlDl-1. HDI HDl-L HDI I HDI-L HDI Hal-I HDI HDI-L HDI HDI-L 1/4 (6.4) 500) 2.2) 500(2.2) 450) 8.0) 450(8.0) 570) 2.5) 570(2.5) 625) 2.8) 625(2.8) 790) 3.5) 790 3.5) 700 3.1) 700( 3.1) 3/8 1 9.5) 890) 4.0) 890(4.0) 965) 4.3) 965(4.3) 1115) 5.0) 1115(5.0) 1250) 5.6) 1250(5.6) 1 1360) 6.0) 1360) 6,0) 1500) 6.7) 1500) 6.7) 1120 ( 5.0) 1120 (5.0) 1500) 6.7) 1500(6.7) 1785(7.9) 1785(7.9) 2125) 9.5) 1940(8.6) 2345 (10.4) 2345(10.4) 2500(11.1) 2500(11.1) 5/8 115.9) 1875) 8.3) - 2500(11.1) - 2920(13.0) - 3250(14.5) - 3715(16.5) - 3750(16.7) - 2500)11.1) - 3875(17.2) - 4065(18.1) - 5000(22.2) - 5565(24.8) - 5500(24.5) - Note: The ultimate shear and allowable shear values are based on the use or SAE Grade 5 bolts, 0r = 85 ksi, F = 120 ksi) with the exception of the 114 HDlIHDI-Linf' = 6000 psi concrete which is based upon the use of a SAE Grade 8 bolt (l - 120 ksi, F, - 150 ksi). Carbon Steel HDI Ultimate Loads in Concrete Anchor size 2000 psi (13.8 MPa) 4000 psi (27.6 MPa) 6000 psi (41.4 MPa) In. 011m) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) HDI HDl-L HDI HDI-I HDI HDI-L HDI HDl-L HDI HDI-L HDI HDI-L 1/4 (6.4) 1995) 8.9) 1995) 8.9) 1800) 8.0) 1800) 8.0) 2270)10.1) 2270(10.1) 2500(11.1) 2500(11,1) 3150(14.0) 3150)14.0) 2800(12.5) 2800(12.5) 3/8 ( 9.5) 3555(15.8) 3555(15.8) 3850(17.1) 3850(17.1) 4480(19.8) 4480(19.8) 5000(22.2) 5000(22.2) 5430(24.2) 5430(24.2) 6000(26.7) 6000(26.7) 4470 (19.9) 4470(19.9) 6000(26.7) 6000(26.7) 7140 (31.8) 7140(31.8) 8500(37.8) 7750(34.4) 9375(41.7) 9375 (41.7) 10000(44.5) 10000(44.5) 7500(33.4) - 0000(44.5) - 11685(52.0) - 13000(57.8) - 14865(66.1) - 15000(66.7) - 10000(4.4.5) - 5500 (69.0) - 16260(72.3) - 20000(89,0) - 2250(99,0) - 22000(97.9) - Carbon Steel HDI Allowable Loads in Lightweight Concrete and Lightweight Concrete over Metal Deck12 Anchor Size Anchor Installed in 3000 psi (20.7 MPa) It Wt. Concrete3 Anchor Installed Through Steel Deck Upper Flute Into 3000 psi (20.7 MPa) It. Wt. Concrete4 Anchor Installed Through Steel Deck Lower Flute Into 3000 psi (20.7 MPa) U. Wt. Concrete4 in. (mm) Tension, lb (kN) Shear, lb (kN) Tension, lb (kN) Shear, lb (kN) Tension, lb (kN) Shear, lb (kN) 1/4(6.4) 465 (2.1) 340 (1.5) 530 (2.4) 335(l.5) 375(l.7) 250(1.1) 3/8(9.5) 755 (3.4) 940 (4.2) 880(3.9) 1010 (4.5) 500 (2.2) 500 (2.2) 1/2(12.7) 1135 (5.0) 1700 (7.6) 1105 (4.9) 1755 (7.8) 625 (2.8) 750 (3.3) 5/8(15.9) 1465 (6.5) 2835 (12.6) - - 875 (3.9) 875 (3.9) 3/4(19.1) 2075 (9.2) 3680(16.4) - - 1250(5.5) 1000 (4.4) S Li 1 The allowable values are based on the use 01 SAE Grade 2 bolts installed in the anchors. 2 Based on using a safety Factor of 4.0. Stainless Steel HDI Allowable Loads in Concrete The tabulated shear and tensile values are for anchors installed in structural light- weight concrete having the designated ultimate compressive strength at the time of installation. The concrete must comply with ASTM C 330-71. The tabulated shear and tensile values are For anchors installed through 20 gauge intermediate decking into structural lightweight concrete having the designated ultimate strength at the time 01 installation. The concrete must comply with ASTM C 330-77. Anchor size in. (mm) 4000 psi (27.6 MPa) 6000 psi (41.4 MPa) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) SS HDI -1/4 (6.4) 480 (2.1) 600 (2.7) 740 (3.3) 600 (2.7) SS HDI -3/8 (9.5) 1040 (4.6) 1230 (5.5) 1460 (6.5) 1230 (5.5) SS HDI -1/2 (12.7) 1840 (8.2) 2760 (12.4) 2410 (10.7) 2760 (12.3) SS HDI -5/8 (15.9) 2630(11.7) 4510 (20.1) 3770 (16.8) 4510 (20.1) SS HDI -3/4 (19.1) 3830 (17.0) 5580 (24.8) 5030 (22.4) 5580 (24.8) Note The ultimate and allowable shear values are based on the use of Type 18-8 bolts. Stainless Steel HDI Ultimate Loads in Concrete Anchor size in. (mm) 4000 psi (27.6 MPa) 6000 psi (41.4 MPa) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) SS HUI - 1/4 (6.4) 1930 (8.6) 2400 (10.7) 2950 (13.1) 2400 (10.7) SS HDI -3/8 (9.5) 4170 (18.5) 4920 (21.9) 5850 (26.0) 4920 (21.9) SS HDI -1/2 (12.7) 7350 (32.7) 11040 (49.1) 9630 (42.8) 11040 (49.1) SSHDI-5/8 (15.9) 10540 (46.9) 18040 (80.2) 15100 (67.2) 18040 (80.2) SS HDI - 3/4 (19.1) 15340 (68.2) 22320 (99.3) 20130 (89.5) 22320 (99.3) 25 Hilti, Inc. (US) 1.800-879-8000 1 www.us.hllti.com I en espahol 1-800-879-5000 1 Hf ti (Canada) Corp. 1.800-363-4458 1 www.hilti.ca I Product Technical Guide 2008 363 : i j ti :1.] Drop-inrvrAnchorr Anchor Spacing and Edge Distance Guidelines (See Anchoring Technology Section 4.1.3) Anchor Spacing Adjustment Factors S = Actual Spacing Smin = 2.0 hnom = 3.5 hnom Sr 3.0' Shear& " 111 2.0 Smin S I 1.0 0 I 0 .2 .4 .6 .8 1.0 Anchor Spacing Adjustment Factor (1A) Edge Distance Adjustment Factors c = Actual edge distance Cmtn = 2.0 hnom Ccr = 3.0 hnom Ccr 3.0 Shear : __ __ . rIi!! 2.0 -- __ 1.0- 0 1 11111 I 0 .2 .4 .6 .8 1.0 Edge Distance Adjustment Factor (f RV 1Rn) Influence of Anchor Spacing & Edge Distance 'IA, R Anchor Size in. (mm) hnom In. (mm) 1/4(6.4) 1(25) 3/8(9,5) 1-9/16(40) 1/2(12.7) 2(51) 5/8(15.8) 2-9/16(65) 3/4(19.1) 3-3/16(81) h,., = standard embedment depth Load Adjustment Factors (Anchor Spacing) fA Load Adjustment Factors (Edge Distance) f Tension/Shear Loads Tension, f,, Shear, Spacing S in. (mm) Anchor Diameter Edge Distance C in. (mm) Anchor Diameter Anchor Diameter 1/4 3/8 1/2 5/8 314 1/4 3/8 1/2 5/8 3/4 1/4 3/8 1/2 5/8 3/4 2 (51) .50 - - - 2 (i) .80 - - .65 -1I2 () .67 - - 2-1/2 LL .90 - - .83 ( - 83 0 - - 3 tO O - 1.0 .65 -1/2( 1.0 8 - - - 3-1/2 (89) - 85 1 - .73 1 - 4 (102) - 9 0 - 4 (102) -.91 0 85 5 - 4-1/2(114 - 79 8 - 4-1/2(114) - .98 85 1 .96 .74 5(127) O.67.50 5(127) 1.0.90.80 t083 .65 - 5-1/2(140) - 1.0 75 .55 - 5-1/2 (140) - .95 83 .91 10 6(152) 3 .61 50 6(152) tO .87 tO 17 7(178) 1 1 1.0 .74 L 6-1/2 (165) 1 .91 .80 1 - - .84 .65 8(203) 7.67 7(178) 584 J2 9(229) - - - tO 17 8(203) - - to o - - 1.0 .83 10 (254) - - - - .88 9 (229) - - - - .96 - - .94 11 (279) - - - - .98 10 (254) - - 1.0 - 1.0 12 (305) 1.0 S 2.0 hnom, S0 = 3.5 h o fA = 0.33 s- 0.17 h,yj,,, for Scr> S> Smin cmin = 2.0 hnom, C0 = 3.0 h, fRN = 0.2 ci- 0.4 hnom for C > Cmin cmin = 2.0 hnom, Ccr = 3.0 hnom ffiv = 0.35 c- 0.05 hnom for cc, > C> cmin 364 Huh, Inc. (US) 1-800-879-8000 1 www.us.hihtl.com I en espahol 1-800-879-5000 1 Huh (Canada) Corp. 1-800-363.4458 1 www.hiltl.ca I Product Technical Guide 2008