Loading...
HomeMy WebLinkAbout2091 RUTHERFORD RD; ; AS120084; PermitUlty oT uarlsbacl Sprinkler Permit Permit No: AS120084 2091 RUTHERFORD Job Address: Status: APPROVED RD Permit Type: SPRINK Applied 7/25/2012 Parcel No: 2121202500 Approved: 7/30/2012 Lot #: 0 Reference No.: Issued: 7/30/2012 PC #: Inspector: Project Title: NIXON PRODUCTS - OFFICE OFFICE AREA FIRE SPRINKLER T.I. ONLY Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON POWAYCA 858-513-4949 Owner: CRUZAN-MON ROE A E W RUTHERFORD L L C 221 15TH ST DEL MAR CA Fees(s) Add'l Fees ($) Total ($) Balance ($) 1 262 j 0 262 0 4251 K-factor Quick Response Standard Coverage CENTRAL Upright, Pendent & Rec. Pendent Glass Bulb Automatic Sprinkler Tyco Fire Products --- www.centralsprinkler.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sates: Tel: (215) 362-0700/ Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 A .5 12,o o24- should be considered, as a minimum, General along with the corrosive nature of the Description The Central Model By-OR, 4.2 & 5.6 K-factor (7/16" & 1/2" orifice) & Model BVLO-QR, 8.0 K-factor (17/32" orifice), Upright, Pendent, and Rec. Pendent Sprinklers are quick response - standard coverage, decorative glass bulb type spray sprinklers designed for use in light & ordinary hazard, commercial occupancies such as banks, hotels, shopping malls etc. The recessed version of the Central Model By-OR, intended for use in areas with a finished ceiling, uses a two-piece Model BV Res/OR Recessed Escutcheon (Vented or Unvented). The Model BV Res/QR Recessed Escutcheon provides up to 3/8 inch (9,5 mm) of total adjustment from the flush pendent position. The recessed version of the Central Model BVLO-QR, also intended for use in areas with a finished ceiling, uses a two-piece Model ELO Recessed Escutcheon. The Model ELO Recessed Escutcheon provides up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by these Recessed Escutcheons reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. These sprinklers are available with a polyester coating that may be utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although polyester coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of this corrosion resistant coating for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, chemical to which the sprinklers will be exposed. Operation: The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate & flow water. WARNING The Model BV-QR & BVLO-QR Uptight, Pendent & Rec. Pendant Sprinklers described herein must be installed and maintained in compliance Mth this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Figure 1 - Cross Section Model BVLO-QR, Upright Sprinkler COMPRESSION DEFLECTOR SCREW GLASS BULB OPERATING ELEMENT J SPRINKLER FRAME BUTTON ETED SPRING ASSEMBLY PLATE (BELLEVILLE SEAL) Standard Spray Upright, Pendent & Rec. Pendent Sprinklers No. 1-7.0 Figure 2 - Model By-OR, Upright, Pendent & Rec. Pendent Sprinkler 1-1/16 1/2 NPT (27,0 mm)__ 2-1/16 "IV8.LN30 II I III (52,4 mm) WRENCH tL12JJ A (52, mm) CENTRAL 1/2 NPT 1-1/16" / (27,0 mm) ELEVATION VIEW , I FACE OF REDUCING COUPLING 3/' (9,5 mm) - Mm. 3/4' (19,1 mm) 1V1N30 . I OUTER I ESCUTCHEON \FZSHED ENG LINE RING I MODEL DV Res/OR RECESSED I RECESSED SUPPORT CUP ESCUTCHEON 2-1/4 ' (57,2 mm) Max. - - Table 1 - Laboratory Listings and Approvals, Model By-OR SPRINKLER FINISH & STYLE Temperature Rating Bulb Color Code Natural Brass Chrome Plated Polyester Coated Recessed 1350F/57°C Orange 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4 155°F/68°C Red 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4 1750F1791C Yellow i ,2,3,4 1,2,3,4 1,2,3',4 1 ,2,3**,4 2000F/931C Green 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4 250°F/121°C Blue 1,2,3,4 1,2,3,4 1,2,3°,4 Listed by Underwriters Laboratories, Inc. - (K = 4.2 & 5.6) Listed by Underwriters Laboratories of Canada. - (K = 4.2 & 5.6) Approved by Factory Mutual Research Corporation. - (K = 5.6) Approved by the City of New York under MEA 466-92-E Vol. III. - (K = 4.2 & 5.6) * Pendent Only. ** Only Approved with the Series BV Res/QR (Vented) Recessed Escutcheon Assy. Technical Data Sprinkler Identification Number SIN C2201 - By-OR Pend (K=4.2) SIN C2101 - By-OR UP (K=4.2) SIN C3201 - BV-QR Pend (K=5.6) SIN C3101 - BV-QR UP (K=5.6) SIN C4201 - BVLO-QR Pend (K=8.0)*- SIN C4101 - BVLO-QR UP (K=8.0)..- Approvals UL, ULC&C-ULListed. FM & NYC Approved (Refer to Table 1 -2. The approvals apply only to the service conditions indicated in the Design Criteria Section) Maximum Working Pressure 175 psi (12,1 bar) 250 psi (17,3 bar) UL & ULC (K=5.6) Pipe Thread Connection .4. 1/2 inch NPT - (K=4.2 & 5.6) 3/4 inch NPT - (K=8.0) Discharge Coefficient K = 4.2 GPM/psi1 (60,5 LPM/bar1 ) . K = 5.6 GPMIpsi1 (80,6 LPM/bar1 ) 4 K = 8.0 GPMIpsi1 (115,2 LPMibar) Temperature Ratings 135°F/570C, 155°F/68°C, 175°F/79°C 200°17/93°C, 250°F/1 21°C Finishes Sprinkler: White Polyester, Chrome Plated, or Natural Brass Rec. Escutcheon: White Cad, Chrome Plated, or Brass Plated Corrosion Resistant Coatings Sprinkler: White Polyester (UL only) Head Guard & Water Shield: G-3 (Guard) - (K=5.6) Up & Pend. WSG-3 (Guard & Shield) - (K=5.6) Up WS-3 (Shield) - (K=5.6) Pendent (See Data Sheet 3-13.0 for details) Physical Characteristics The Model BV-QR & BVLO-QR Upright, Pendent & Rec. Pendent Sprinklers utilize a dezincification resistant (DZR) bronze frame and a 3 mm bulb. The two-piece button assembly is brass and copper. The sprinkler frame orifice is sealed with a gasketed spring plate (Belleville Seal) consisting of a beryllium nickel disc spring that is sealed on both its inside and outside edges with a TeflonTm gasket. The compression screw is bronze, & the deflector is brass. P6-4f>5 /A-TC4A LSi Model BV-20 QR 8.0 K-factor Quick Response Extended Coverage Light Hazard Pendent & Rec. Pendent Glass Bulb Automatic Sprinkler Tyco Fire Products --- www.centralsprinkler.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312/Fax: (800) 791-5500 cp (ENTRA7 General IL. Description The Central Model BV-20 QR, 8.0 K-factor Quick Response, Extended Coverage Light Hazard (ECLH) Pendent and Recessed Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies such as churches, hospitals, offices, and restaurants. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules (e.g., NFPA 13) for the protection of light hazards up to a maximum cover- age area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 225 ft2 (20,9 m2) for standard coverage sprinklers. The recessed version of the Central Model BV-20 OR ECLH, intended for use in areas with a finished ceiling, uses a two-piece Model ELO Recessed Escutcheon. The Model ELO Recessed Escutcheon provides up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by these Recessed Escutch- eons reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Operation: The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate & flow water. WARNING The Model BV-20 QR ECLH Pendent & Rec. Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Technical Data Sprinkler Identification Number SIN C4232 Approvals UL & ULC Listed. (The approvals apply only to the service conditions indicated in the Design Criteria Section) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficient K = 8.0 GPM/psi (115,2 LPM/bar) Temperature Ratings 1351F/571C or 155°F/68°C Finishes Sprinkler White Polyester, Chrome Plated, or Natural Brass Rec. Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics The Model BV-20 OR ECLH Pendent & Rec. Pendent Sprinklers utilize a dezincifi- cation resistant (DZR) bronze frame and a 3 mm bulb. The two-piece button assembly is brass and copper. The sprinkler frame orifice is sealed with a gasketed spring plate (Belleville Seal) consisting of a beryllium nickel disc spring that is sealed on both its inside and outside edges with a Teflon gasket. The compression screw is bronze, & the deflector is brass. Extended Coverage Light Hazard Pendent & Rec. Pendent Sprinklers Figure 1 - Cross Section Model BV-20 QR ECLH, Pendent Sprinkler GASKETED SPRING BUTTON PLATE ASSEMBLY (BELLEVILLE SEAL) SPRINKLER FRAME GLASS BULB I -1i II)- OPERATING ELEMENT / DEFLECTOR COMPRESSION SCREW No. 2-10.0 Figure 2 - Model BV-20 OR ECLH, Pendent & Recessed Pendent Sprinklers ELEVATION VIEW / FACE OF REDUCING COUPLING 3/4 NPT / 2-1/8" 1VIN0 OUTER / (54,0 mm) WRENCH ESCUTCHEON FLAT RING RECESSED 1-3/16" _j SUPPORT CUP (30,2 mm) L.. 3/8" (9,5 mm) U1-1/8"28,6mrn) IV81Na3 FINISHED W \CEILING LINE ENCH FLAT MODEL ELO I RECESSED 2-1/4" (57,2 mm) Mm. 2-3/4" (69,9 mm) Max. ESCUTCHEON - 3-1/4" (82,6 mm) AI I'..4 #4fl7 Figure 4- ELO Offset Wrench (Part #1093) Table I - UL and ULC Listing Criteria for the Installation of Model BV-20 OR Extended Coverage Light Hazard Pendent Sprinklers Minimum Spacing Flow/Pressure Style Temperature Rating LH (0.1 gpm/sq. ft.) 16'x 16' 26.0 gpm / 10.6 psi Pendent 1351F/571C 1550F/681C (4,9 m x 4,9 m) 98,4 Lpm / 0,73 bar Recessed Pendent 1351F/571C 155°F/68°C 18'x 18' 33.0 gpm / 17.0 psi Pendent 1350F/570C 155°F/680C (5,5 mx 5,5 m) 124,9 Lpm / 1,17 bar Recessed Pendent 1350F/571C --- 20'x 20' 40.0 gpm / 25.0 psi Pendent 135°F/57°C (6,1 m x 6,1 m) 151,4 Lpm / 1,72 bar Recessed Pendent 1350F/570C Design Criteria The Model BV-20 OR, Extended Coverage Light Hazard (ECLH) Pendent and Recessed Pendent Sprinklers are UL and ULC listed for use in light hazard occupancies, using the design criteria in Table 1 as well as any additional requirements specified in current NFPA 13 Standards for Extended Coverage Pendent Sprinklers. The minimum lateral spacing between the BV-20 QR ECLH Pendent and Recessed Pendent Sprinkers to prevent cold soldering, is 8 feet (2,4 m). The Model BV-20 OR Sprinklers can be used with any metalic flush or extended escutcheon, provided the maximum ceiling to top of sprinkler deflector dimension specified in NFPA 13 is maintained. For recessed applications, only the Model ELO Recessed Escutcheon Assemblies may be used. K3 Installation The Model BV-20 OR ELCH Sprinklers must be installed in accordance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble with an approximate diameter of 1/16 inch should be present. A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install 3/4 inch NPT sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent position. The deflector is to be parallel to the ceiling, roof, or mounting surface, as applicable. Step 2. After installing the ELO support cup (or other escutch- eon, as applicable) over the sprinkler pipe threads & with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler using only the following wrenches: BV-20 OR Pend - W-Type 3 (Ref. Fig. 3) BV-20 OR Rec. Pend - ELO Offset (Ref. Fig. 4) Wrenches are to be applied to the sprinkler wrench flats (Ref. Fig. 2) only. a Care & Maintenance The Model BV-20 OR ECLH Sprinklers must be main- tained and serviced in accordance with the following instructions. NOTES Absence of an escutcheon which is used to cover a clearance hole, may delay the time to operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system it controls, permission to shut down the affected fire protec- tion systems must be obtained from the proper authorities. All personnel who may be affected by this action must be notified. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be shipped or stored where their temperatures will exceed 100°F/380C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Sec- tion). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited n Ordering Warranty Information Products manufactured by Tyco Fire Ordering Information: When placing an Products are warranted solely to the order, indicate the full product name. original Buyer for ten (10) years Please specify the quantity, model, style, against defects in material and orifice size, temperature rating, type of workmanship when paid for and finish or coating, and sprinkler wrench. properly installed and maintained Refer to price list for complete listing of under normal use and service. This Part Numbers. warranty will expire ten (10) years Teflon is a trademark of the DuPont Corp. from date of shipment by Tyco Fire Products. No warranty is given for products or components manufac- tured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, im- proper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or, replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's repre- sentatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. tqcn/ Flow Control Tycooducts Fire /Pr Printed in U.S.A. 2-01