HomeMy WebLinkAbout2091 RUTHERFORD RD; ; AS120084; PermitUlty oT uarlsbacl
Sprinkler Permit
Permit No: AS120084
2091 RUTHERFORD
Job Address: Status: APPROVED
RD
Permit Type: SPRINK Applied 7/25/2012
Parcel No: 2121202500 Approved: 7/30/2012
Lot #: 0
Reference No.: Issued: 7/30/2012
PC #: Inspector:
Project Title: NIXON PRODUCTS - OFFICE OFFICE AREA FIRE SPRINKLER T.I.
ONLY
Applicant:
WESTERN FIRE PROTECTION
13630 DANIELSON
POWAYCA
858-513-4949
Owner:
CRUZAN-MON ROE A E W RUTHERFORD L L C
221 15TH ST
DEL MAR CA
Fees(s) Add'l Fees ($) Total ($) Balance ($) 1
262 j 0 262 0
4251 K-factor
Quick Response
Standard Coverage CENTRAL
Upright, Pendent & Rec. Pendent Glass Bulb Automatic Sprinkler
Tyco Fire Products --- www.centralsprinkler.com
451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA
Customer Service/Sates: Tel: (215) 362-0700/ Fax: (215) 362-5385
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 A .5 12,o o24-
should be considered, as a minimum, General along with the corrosive nature of the
Description
The Central Model By-OR, 4.2 & 5.6
K-factor (7/16" & 1/2" orifice) & Model
BVLO-QR, 8.0 K-factor (17/32" orifice),
Upright, Pendent, and Rec. Pendent
Sprinklers are quick response - standard
coverage, decorative glass bulb type
spray sprinklers designed for use in light &
ordinary hazard, commercial occupancies
such as banks, hotels, shopping malls etc.
The recessed version of the Central Model
By-OR, intended for use in areas with a
finished ceiling, uses a two-piece Model
BV Res/OR Recessed Escutcheon
(Vented or Unvented). The Model BV
Res/QR Recessed Escutcheon provides
up to 3/8 inch (9,5 mm) of total adjustment
from the flush pendent position. The
recessed version of the Central Model
BVLO-QR, also intended for use in areas
with a finished ceiling, uses a two-piece
Model ELO Recessed Escutcheon. The
Model ELO Recessed Escutcheon
provides up to 3/4 inch (19,1 mm) of total
adjustment from the flush pendent
position. The adjustment provided by
these Recessed Escutcheons reduces the
accuracy to which the fixed pipe drops to
the sprinklers must be cut.
These sprinklers are available with a
polyester coating that may be utilized to
extend the life of copper alloy sprinklers
beyond that which would otherwise be
obtained when exposed to corrosive
atmospheres.
Although polyester coated sprinklers have
passed the standard corrosion tests of the
applicable approval agencies, the testing
is not representative of all possible
corrosive atmospheres. Consequently, it is
recommended that the end user be
consulted with respect to the suitability of
this corrosion resistant coating for any
given corrosive environment. The effects
of ambient temperature, concentration of
chemicals, and gas/chemical velocity,
chemical to which the sprinklers will be
exposed.
Operation: The glass bulb contains a fluid
which expands when exposed to heat.
When the rated temperature is reached,
the fluid expands sufficiently to shatter the
glass bulb, which then allows the sprinkler
to activate & flow water.
WARNING
The Model BV-QR & BVLO-QR Uptight,
Pendent & Rec. Pendant Sprinklers
described herein must be installed and
maintained in compliance Mth this
document, as well as with the applicable
standards of the National Fire Protection
Association, in addition to the standards of
any other authorities having jurisdiction.
Failure to do so may impair the integrity of
these devices.
The owner is responsible for maintaining
their fire protection system and devices in
proper operating condition. The installing
contractor or sprinkler manufacturer
should be contacted relative to any
questions.
Figure 1 - Cross Section
Model BVLO-QR,
Upright Sprinkler
COMPRESSION DEFLECTOR SCREW
GLASS BULB
OPERATING ELEMENT J SPRINKLER
FRAME
BUTTON ETED SPRING
ASSEMBLY PLATE
(BELLEVILLE
SEAL)
Standard Spray
Upright, Pendent
& Rec. Pendent
Sprinklers
No. 1-7.0
Figure 2 - Model By-OR, Upright, Pendent & Rec. Pendent Sprinkler
1-1/16
1/2 NPT (27,0 mm)__
2-1/16 "IV8.LN30 II I III
(52,4 mm) WRENCH tL12JJ A (52, mm)
CENTRAL
1/2 NPT
1-1/16" /
(27,0 mm)
ELEVATION VIEW
, I FACE OF
REDUCING
COUPLING
3/' (9,5 mm)
- Mm.
3/4' (19,1 mm)
1V1N30 . I
OUTER I
ESCUTCHEON
\FZSHED
ENG LINE
RING I
MODEL DV Res/OR
RECESSED I RECESSED
SUPPORT CUP ESCUTCHEON
2-1/4 ' (57,2 mm) Max.
- -
Table 1 - Laboratory Listings and Approvals, Model By-OR
SPRINKLER FINISH & STYLE
Temperature
Rating
Bulb
Color Code
Natural
Brass
Chrome
Plated
Polyester
Coated
Recessed
1350F/57°C Orange 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4
155°F/68°C Red 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4
1750F1791C Yellow i ,2,3,4 1,2,3,4 1,2,3',4 1 ,2,3**,4
2000F/931C Green 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4
250°F/121°C Blue 1,2,3,4 1,2,3,4 1,2,3°,4
Listed by Underwriters Laboratories, Inc. - (K = 4.2 & 5.6)
Listed by Underwriters Laboratories of Canada. - (K = 4.2 & 5.6)
Approved by Factory Mutual Research Corporation. - (K = 5.6)
Approved by the City of New York under MEA 466-92-E Vol. III. - (K = 4.2 & 5.6)
* Pendent Only.
** Only Approved with the Series BV Res/QR (Vented) Recessed Escutcheon Assy.
Technical
Data
Sprinkler Identification Number
SIN C2201 - By-OR Pend (K=4.2)
SIN C2101 - By-OR UP (K=4.2)
SIN C3201 - BV-QR Pend (K=5.6)
SIN C3101 - BV-QR UP (K=5.6)
SIN C4201 - BVLO-QR Pend (K=8.0)*-
SIN C4101 - BVLO-QR UP (K=8.0)..-
Approvals
UL, ULC&C-ULListed.
FM & NYC Approved
(Refer to Table 1 -2. The approvals apply
only to the service conditions indicated in
the Design Criteria Section)
Maximum Working Pressure
175 psi (12,1 bar)
250 psi (17,3 bar) UL & ULC (K=5.6)
Pipe Thread Connection
.4. 1/2 inch NPT - (K=4.2 & 5.6)
3/4 inch NPT - (K=8.0)
Discharge Coefficient
K = 4.2 GPM/psi1 (60,5 LPM/bar1 )
. K = 5.6 GPMIpsi1 (80,6 LPM/bar1 )
4 K = 8.0 GPMIpsi1 (115,2 LPMibar)
Temperature Ratings
135°F/570C, 155°F/68°C, 175°F/79°C
200°17/93°C, 250°F/1 21°C
Finishes
Sprinkler: White Polyester, Chrome Plated,
or Natural Brass
Rec. Escutcheon: White Cad, Chrome
Plated, or Brass Plated
Corrosion Resistant Coatings
Sprinkler: White Polyester (UL only)
Head Guard & Water Shield:
G-3 (Guard) - (K=5.6) Up & Pend.
WSG-3 (Guard & Shield) - (K=5.6) Up
WS-3 (Shield) - (K=5.6) Pendent
(See Data Sheet 3-13.0 for details)
Physical Characteristics
The Model BV-QR & BVLO-QR Upright,
Pendent & Rec. Pendent Sprinklers utilize
a dezincification resistant (DZR) bronze
frame and a 3 mm bulb. The two-piece
button assembly is brass and copper. The
sprinkler frame orifice is sealed with a
gasketed spring plate (Belleville Seal)
consisting of a beryllium nickel disc spring
that is sealed on both its inside and outside
edges with a TeflonTm gasket. The
compression screw is bronze, & the
deflector is brass.
P6-4f>5 /A-TC4A LSi
Model BV-20 QR
8.0 K-factor
Quick Response
Extended Coverage Light Hazard
Pendent & Rec. Pendent Glass Bulb Automatic Sprinkler
Tyco Fire Products --- www.centralsprinkler.com
451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA
Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385
Technical Services: Tel: (800) 381-9312/Fax: (800) 791-5500
cp (ENTRA7
General IL. Description
The Central Model BV-20 QR,
8.0 K-factor Quick Response, Extended
Coverage Light Hazard (ECLH)
Pendent and Recessed Pendent
Sprinklers are decorative glass bulb
sprinklers designed for use in light
hazard occupancies such as churches,
hospitals, offices, and restaurants.
They are intended for use in automatic
sprinkler systems designed in accor-
dance with standard installation rules
(e.g., NFPA 13) for the protection of
light hazards up to a maximum cover-
age area of 400 ft2 (37,2 m2), as
compared to the maximum coverage
area of 225 ft2 (20,9 m2) for standard
coverage sprinklers.
The recessed version of the Central
Model BV-20 OR ECLH, intended for
use in areas with a finished ceiling, uses
a two-piece Model ELO Recessed
Escutcheon. The Model ELO Recessed
Escutcheon provides up to 3/4 inch
(19,1 mm) of total adjustment from the
flush pendent position. The adjustment
provided by these Recessed Escutch-
eons reduces the accuracy to which the
fixed pipe drops to the sprinklers must
be cut.
Operation: The glass bulb contains a
fluid which expands when exposed to
heat. When the rated temperature is
reached, the fluid expands sufficiently to
shatter the glass bulb, which then
allows the sprinkler to activate & flow
water.
WARNING
The Model BV-20 QR ECLH Pendent &
Rec. Pendent Sprinklers described
herein must be installed and maintained
in compliance with this document, as
well as with the applicable standards of
the National Fire Protection Association,
in addition to the standards of any other
authorities having jurisdiction. Failure to
do so may impair the integrity of these
devices.
The owner is responsible for maintain-
ing their fire protection system and
devices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
relative to any questions.
Technical
Data
Sprinkler Identification Number
SIN C4232
Approvals
UL & ULC Listed.
(The approvals apply only to the service
conditions indicated in the Design Criteria
Section)
Maximum Working Pressure
175 psi (12,1 bar)
Pipe Thread Connection
3/4 inch NPT
Discharge Coefficient
K = 8.0 GPM/psi (115,2 LPM/bar)
Temperature Ratings
1351F/571C or 155°F/68°C
Finishes
Sprinkler White Polyester, Chrome
Plated, or Natural Brass
Rec. Escutcheon: White Coated, Chrome
Plated, or Brass Plated
Physical Characteristics
The Model BV-20 OR ECLH Pendent &
Rec. Pendent Sprinklers utilize a dezincifi-
cation resistant (DZR) bronze frame and a
3 mm bulb. The two-piece button
assembly is brass and copper. The
sprinkler frame orifice is sealed with a
gasketed spring plate (Belleville Seal)
consisting of a beryllium nickel disc spring
that is sealed on both its inside and
outside edges with a Teflon gasket. The
compression screw is bronze, & the
deflector is brass.
Extended
Coverage Light
Hazard Pendent
& Rec. Pendent
Sprinklers
Figure 1 - Cross Section
Model BV-20 QR ECLH,
Pendent Sprinkler
GASKETED SPRING
BUTTON PLATE
ASSEMBLY (BELLEVILLE
SEAL)
SPRINKLER
FRAME GLASS BULB I -1i II)- OPERATING
ELEMENT
/
DEFLECTOR COMPRESSION
SCREW
No. 2-10.0
Figure 2 - Model BV-20 OR ECLH, Pendent & Recessed Pendent Sprinklers
ELEVATION VIEW
/ FACE OF
REDUCING
COUPLING
3/4 NPT
/
2-1/8"
1VIN0
OUTER /
(54,0 mm) WRENCH ESCUTCHEON
FLAT RING
RECESSED
1-3/16" _j SUPPORT CUP
(30,2 mm)
L.. 3/8" (9,5 mm)
U1-1/8"28,6mrn)
IV81Na3
FINISHED W \CEILING LINE
ENCH
FLAT MODEL ELO
I RECESSED
2-1/4" (57,2 mm) Mm.
2-3/4" (69,9 mm) Max.
ESCUTCHEON
- 3-1/4" (82,6 mm)
AI I'..4 #4fl7 Figure 4- ELO Offset Wrench (Part #1093)
Table I - UL and ULC Listing Criteria for the Installation of Model BV-20 OR
Extended Coverage Light Hazard Pendent Sprinklers
Minimum
Spacing Flow/Pressure Style Temperature Rating
LH (0.1 gpm/sq. ft.)
16'x 16' 26.0 gpm / 10.6 psi Pendent 1351F/571C 1550F/681C
(4,9 m x 4,9 m) 98,4 Lpm / 0,73 bar Recessed Pendent 1351F/571C 155°F/68°C
18'x 18' 33.0 gpm / 17.0 psi Pendent 1350F/570C 155°F/680C
(5,5 mx 5,5 m) 124,9 Lpm / 1,17 bar Recessed Pendent 1350F/571C ---
20'x 20' 40.0 gpm / 25.0 psi Pendent 135°F/57°C
(6,1 m x 6,1 m) 151,4 Lpm / 1,72 bar Recessed Pendent 1350F/570C
Design
Criteria
The Model BV-20 OR, Extended Coverage Light Hazard
(ECLH) Pendent and Recessed Pendent Sprinklers are UL
and ULC listed for use in light hazard occupancies, using the
design criteria in Table 1 as well as any additional
requirements specified in current NFPA 13 Standards for
Extended Coverage Pendent Sprinklers.
The minimum lateral spacing between the BV-20 QR ECLH
Pendent and Recessed Pendent Sprinkers to prevent cold
soldering, is 8 feet (2,4 m).
The Model BV-20 OR Sprinklers can be used with any metalic
flush or extended escutcheon, provided the maximum ceiling
to top of sprinkler deflector dimension specified in NFPA 13 is
maintained. For recessed applications, only the Model ELO
Recessed Escutcheon Assemblies may be used.
K3 Installation
The Model BV-20 OR ELCH Sprinklers must be installed in
accordance with the following instructions:
NOTES
Do not install any bulb type sprinkler if the bulb is cracked
or there is a loss of liquid from the bulb. With the sprinkler
held horizontally, a small air bubble with an approximate
diameter of 1/16 inch should be present.
A leak tight 3/4 inch NPT sprinkler joint should be obtained
with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum
of 30 ft.lbs. (40,7 Nm) of torque is to be used to install 3/4 inch
NPT sprinklers. Higher levels of torque may distort the
sprinkler inlet with consequent leakage or impairment of the
sprinkler.
Do not attempt to compensate for insufficient adjustment in an
Escutcheon Plate by under- or over-tightening the Sprinkler.
Readjust the position of the sprinkler fitting to suit.
Step 1. Pendent sprinklers must be installed only in the
pendent position. The deflector is to be parallel to the ceiling,
roof, or mounting surface, as applicable.
Step 2. After installing the ELO support cup (or other escutch-
eon, as applicable) over the sprinkler pipe threads & with pipe
thread sealant applied to the pipe threads, hand tighten the
sprinkler into the sprinkler fitting.
Step 3. Wrench tighten the sprinkler using only the following
wrenches:
BV-20 OR Pend - W-Type 3 (Ref. Fig. 3)
BV-20 OR Rec. Pend - ELO Offset (Ref. Fig. 4)
Wrenches are to be applied to the sprinkler wrench flats (Ref.
Fig. 2) only.
a Care &
Maintenance
The Model BV-20 OR ECLH Sprinklers must be main-
tained and serviced in accordance with the following
instructions.
NOTES
Absence of an escutcheon which is used to cover a
clearance hole, may delay the time to operation in a fire
situation.
Before closing a fire protection system main control valve
for maintenance work on the fire protection system it
controls, permission to shut down the affected fire protec-
tion systems must be obtained from the proper authorities.
All personnel who may be affected by this action must be
notified.
Sprinklers which are found to be leaking or exhibiting
visible signs of corrosion must be replaced.
Automatic sprinklers must never be shipped or stored
where their temperatures will exceed 100°F/380C and they
must never be painted, plated, coated or otherwise altered
after leaving the factory. Modified sprinklers must be
replaced. Sprinklers that have been exposed to corrosive
products of combustion, but have not operated, should be
replaced if they cannot be completely cleaned by wiping the
sprinkler with a cloth or by brushing it with a soft bristle
brush.
Care must be exercised to avoid damage - before, during,
and after installation. Sprinklers damaged by dropping,
striking, wrench twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler that has a cracked bulb
or that has lost liquid from its bulb (Ref. Installation Sec-
tion).
The owner is responsible for the inspection, testing, and
maintenance of their fire protection system and devices in
compliance with this document, as well as with the appli-
cable standards of the National Fire Protection Association
(e.g., NFPA 25), in addition to the standards of any other
authorities having jurisdiction. The installing contractor or
sprinkler manufacturer should be contacted relative to any
questions.
It is recommended that automatic sprinkler systems be
inspected, tested, and maintained by a qualified Inspection
Service.
Limited
n
Ordering
Warranty Information
Products manufactured by Tyco Fire Ordering Information: When placing an Products are warranted solely to the order, indicate the full product name.
original Buyer for ten (10) years Please specify the quantity, model, style,
against defects in material and orifice size, temperature rating, type of
workmanship when paid for and finish or coating, and sprinkler wrench.
properly installed and maintained Refer to price list for complete listing of
under normal use and service. This Part Numbers.
warranty will expire ten (10) years Teflon is a trademark of the DuPont Corp. from date of shipment by Tyco Fire
Products. No warranty is given for
products or components manufac-
tured by companies not affiliated by
ownership with Tyco Fire Products or
for products and components which
have been subject to misuse, im-
proper installation, corrosion, or which
have not been installed, maintained,
modified or repaired in accordance
with applicable Standards of the
National Fire Protection Association,
and/or the standards of any other
Authorities Having Jurisdiction.
Materials found by Tyco Fire Products
to be defective shall be either repaired
or, replaced, at Tyco Fire Products'
sole option. Tyco Fire Products
neither assumes, nor authorizes any
person to assume for it, any other
obligation in connection with the sale
of products or parts of products. Tyco
Fire Products shall not be responsible
for sprinkler system design errors or
inaccurate or incomplete information
supplied by Buyer or Buyer's repre-
sentatives.
IN NO EVENT SHALL TYCO FIRE
PRODUCTS BE LIABLE, IN CON-
TRACT, TORT, STRICT LIABILITY
OR UNDER ANY OTHER LEGAL
THEORY, FOR INCIDENTAL,
INDIRECT, SPECIAL OR CONSE-
QUENTIAL DAMAGES, INCLUDING
BUT NOT LIMITED TO LABOR
CHARGES, REGARDLESS OF
WHETHER TYCO FIRE PRODUCTS
WAS INFORMED ABOUT THE
POSSIBILITY OF SUCH DAMAGES,
AND IN NO EVENT SHALL TYCO
FIRE PRODUCTS' LIABILITY
EXCEED AN AMOUNT EQUAL TO
THE SALES PRICE.
THE FOREGOING WARRANTY IS
MADE IN LIEU OF ANY AND ALL
OTHER WARRANTIES EXPRESS
OR IMPLIED, INCLUDING WARRAN-
TIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR
PURPOSE.
tqcn/ Flow Control Tycooducts Fire /Pr Printed in U.S.A. 2-01