Loading...
HomeMy WebLinkAboutCDP 2022-0039; CASKEY RESIDENCE ADU; Administrative Determination\ -----------~. I '· I . I I I.· ,,: I .I I I • J ,. I • I . I • I I • J • • 1 I I I I I J·· I I I . I I I I d I I I ' I I . I I .. "' " a "' "' 'a a "' st a, cc z z <( _J a. 0 w ~ II ...... ~ "' -~ -w U) _J <{ 0 (/) GENERAL NOTES 00800 SPECIAL CONDITIONS 1. GENERAL: DRAWINGS ARE SCHEMATIC. ALL WORK SHOWN OR REASONABLY INFERRED SHALL BE COMPLETED TO THE HIGHEST STANDARDS OF THE INDUSTRY AND READY FOR OCCUPANCY UNLESS SPECIFICALLY NOTED OTHERWISE. DETAILS AND METHODS NOT OTHERWISE SHOWN ARE LEFT TO THE DISCRETION OF THE CONTRACTOR 2. -THIS PROJECT AND ALL WORK SHALL COMPLY WITH THE 2019 EDITION OF THE CALIFORNIA RESIDENTIAL CODE (BASED ON THE 2018 IRC). 2019 EDITION OF THE CALIFORNIA BUILDING CODE (BASED ON THE 2018 !BC). 11-·IIS PROJECT AND ALL WORK SHALL ALSO COMPLY WITH ALL CITY OF SAN DIEGO MUNICIPAL CODE, AND ALL CITY AND COUNTY REGULATIONS, ORDINANCES AND REQUIREMENTS. 2019 EDITION OF THE CALIFORNIA ELECTRICAL CODE (BASED ON THE 2017 N.E.C.), 2019 EDITION OF THE CALIFORNIA MECHANICAL CODE (BASED ON THE 2018 U.M.C.) 2019 EDITION OF THE CALIFORNIA PLUMBING CODE (BASED ON THE 2018 U.P.C.) 2019 EDITION OF THE CALIFORNIA GREEN BUILDING CODE 2019 EDITION OF THE CALIFORNIA FIRE CODE (BASED ON THE 2018 LF.C.) 2019 EDITION OF THE CALIFORNIA ENERGY CODE. 6. SAFETY: PROVISIONS FOR PROTECTION OF THE PUBLIC AND WORKMEN ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 8. LABOR: ALL WORK SHALL BE PERFORMED IN THE MOST PROFESSIONAL MANNER BY EXPERIENCED MECHANICS SKILLED IN THEIR TRADE. CONSUMPTION OF ALCOHOLIC BEVERAGES IS NOT ALLOWED ON JOBS. SMOKING JS NOT ALLOWED WITHIN THE BUILDING. CONTRACTOR SHALL REMOVE ANY WORKER FROM THE JOB WHO DOES NOT COMPLY WITH THE ABOVE REQUIREMENT OWNER INFORMATION NAME: CASKEY RESIDENCE ADDRESS: 3800 ALDER AVENUE, CARLSBAD CA 92008 PLAN PREPARER NAME: FRANCISCO J. HERRERA ADDRESS: 3142 TIGER RUN CT. #108 CARSBAD, CA 92010 PHONE: (619)450-3370 PARCEL INFORMATION AT REQUEST OF Tr-IE DESIGNER. 1------------------------------fl CONTRACTOR SHALL PROVIDE A QUALIFIED SUPERVISOR ON THE SITE DURING ALL CONSTRUCTION WORK UNLESS SPECIFICALLY EXCEPTED BY OWNER AND/OR CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FIELD MEASUREMENTS FOR BOTH NEW WORK AND EXISTING CONDITIONS. APN: 207-063-24-00 SITE ADDRESS: 3800 ALDER AVENUE, CARLSBAD CA 92008 LOT: 09 CONTRACTOR SHALL COORDINATE THE WORK AND SCHEDULE THE TIMING AS NOT TYPE OF CONSTRUCTION: WOOD LIGHT FRAME TO CAUSE DELAYS TO ANY PHASE OF CONSTRUCTION. THE BUILDING ANO GROUNDS SHALL BE KEPT CLEAN AT ALL TIMES. THE CONTRACTOR SHALL LEA \'E THE SITE SAFE, OROERL Y AND SECURED AT THE END OF EACH WORKDAY. CONTRACTOR SHALL PROTECT EXISTING 8UILDING AND PROPERTY FROM DAMAGE DUE TO CONSTRUCTION ACTIVITIES. REPAIR AT NO ADDITIONAL COST ANY DAMAGE SO INCURRED. UPON SUBSTANTIAL COMPLETION, CONTRACTOR SHALL COMPLETE ALL WORK REQUIRED AT FINAL INSPECTION WITHIN THE TIME THEN AGREED TO AND SHALL DELIVER TO THE OWNER ALL CERTIFICATIONS, WARRANTIES, GUARANTEES, INSTALLATION AND OPERATION INSTRUCTIONS FOR ALL APPLIANCES, DEVICES AND MATERIALS IN CORPORA TED IN THE WORK. THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE DESIGNER, ENGINEER, AND OWNER HARMLESS FOR THE INJURY OR DEA TH TO PERSONS, OR DAMAGE TO PROPERTY, CAUSED BY THE NEGLIGENCE OF THE CONTRACTOR, HIS/HER EMPLOYCES, AGENTS, OR SUBCONTRACTORS EACH CONTRACTOR SHALL BE RESPONSl!JLE FOR THE GENERAL CLEANING OF THE JOB SITE AD BUILDIN(; INTERIOR DURING AND AT THE COMPLETION OF THE WORK. EACH CONTRACTOR JS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND IS RESPONSIBLE FOR THE REPAIR OF SAID DAMAGE AT HIS OWN EXPENSE THE CONTRACTOR SHALL USE THE DIMENSIONS SHOWN ON THE DRAWINGS IN CONJUNCTION WITH ACTUAL FIELD MEASUREMENTS. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS BEST PRESENT KNOWLEDGE. BUT WITHOUT GUARANTEE OF COMPLETE ACCURACY. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY DESIGNER OF ANY DISCREPANOES OR CONDITIONS WHICH MAY ADVERSELY AFFECT THE DESIGN PRIOR TO PROCEEDING WITH THE ITEM OF WORK AFFECTED. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE. ALL DIMENSIONS ARE TO FACE OF FRAMING UNLESS OTHERWISE NOTED. CEILING HEIGHT DIMENSIONS ARE FROM THE FINISHED FLOOR SURFACE TO THE FACE OF THE FINISHED CEILING UNLESS OTHERWISE NOTED WHERE ANY WORK SHOWN ON THESE PLANS DEVIATES FROM THESE CODE REQUIREMENTS, THESE CODE REQUIREMENTS SHALL TAKE PRECEDENCE. NOTIFY THE PROJECT OWNER IN WRITING OF ANY SUCH DEVIATIONS PRIOR TO ANY WORK OR ORDERING MATERIALS. AND FOR ALL STRUCTURAL ITEMS (2016 CRC) AND STRUCTURAL CALCULATIONS 3.-PERMANENT VACUUM BREAKERS SHALL BE INSTAULED WITH ALL NEW HOSE BIBBS. 4.-ALL SHOWERHEAOS FOR ALL SHOWER FIXTURES SHALL BE CERTIFIED AS HAVING MAXIMUM FLOW RATE OF NO MORE THAN 2.0 GALLONS PER MINUTE. ALL LAVATORY FAUCETS SHALL BE EQUIPPED WITH AN AERATOR WITH A CERTIFIED MAXIMUM FLOW RATE OF NO MORE THAN 1.2 GALLONS PER MINUTE. ALL WATER CLOSETS AND ASSOCIATED FLUSHOMETER VALVES, IF ANY, SHALL BE CERTIFIED AS USING NO MORE THAN 1.28 GALLONS PER FLUSH AND SHALL MEET THE PERFORMANCE STANDARDS ESTABLISHED BY THE AMERICAN NATIONAL STANDARD INSTITUTE STANDARD A112.19.2. 5.-WATER PIPING CONNECTIONS SHALL USE LEAD FREE SOLDER. 6.-TEMPERED GLASS SHALL BE PERMANENTLY IDENTIFIED AND VISIBLE WHEN THE UNIT IS GLAZED. 7.-WATER HEATERS (BOILERS) SHALL COMPLY WITH THE CALIFORNIA CPC FOR THERMAL EXPANSION REQUIREMENTS. 8.-THE SAFETY OF FIELD PERSONNa DURING CONSTRUCTION IS THE RESPONSIBILITY OF EACH INSTALLATION CONTRACTOR. INSTALLATION CONTRACTORS SHAU. NOTIFY THE OWNER IF HE FEELS THAT ANY OF THE RECOMMENDED ACTIONS CONTAINED HEREIN TO BE UNSAFE. 9.-EXTERIOR DOORS MAY NOT SWING OUTWARD WHEN THERE IS GREATER THAN A ½"DROP BELOW FINISH FLOOR OF HOUSE. 10.-PWMBING NOTE: ALL PRIMARY CONDENSATE LINES SHALL TERMINATE AT A TRAPPED PLUMBING FIXTURE. 11.-ELECTRICAL NOTE: ALL BEDROOM AND ADJACENT AREA ELECTRICAL OUTLETS SHALL BE PROTECTED BY ARC FAULT CIRCUIT INTERRUPTERS (A.F.CJ). 12.-RECEPTACLE OUTLET LOCATIONS SHALL COMPLY WITH NEC. 13.-THE HIGHEST POINT OF THE ROOF, EQUIPMENT, OR ANY \'ENT, PIPE, ANTENNA OR PROJECTION, SHALL NOT EXCEED 30 FEET ABOVE GRADE. 14.-DIAPHRAGM SHEA THING NAILS OR OTHER APPROVED CONNECTORS SHALL BE DRIVEN SO THAT THEIR HEAD OR CROWN IS FLUSH WITH THE SURF ACE OF THE SHEA THING. 15.-UNAUTHORIZED CHANGES & USES: THE OWNER/BUILDER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE OR LIABLE FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THESE PLANS SHAU. BE IN WRITING AND MUST BE APPROVED BY THE OWNER/BUILDER. 16.-WHERE MATERIALS OR ASSEMBLIES ARE REQUIRED SY THE BUILDING CODE TO BE LABELED, SUCH MATERIALS ANO ASSEMBLIES SHALL BE LABELED BY AN AGENCY APPROVED BY THE CITY OF SAN DIEGO IN ACCORDANCE WITH SECTION 1703 OF THE CBC. PRODUCTS AND MATERIALS TO BE LABELED SHALL BE 1ESTED, INSPECTED AND LABELED IN ACCORDANCE WITH THE PROCEDURES SET FORTH IN SECTIONS 1703.5.1 THROUGH 17D3.5.3. 17.-BATHROOM AND LAUNDRY EXHAUST FANS SHALL PROVIDE MINIMUM 5 AIR CHANGES PER HOUR. A 1 OD SQ. INCHES OF MAKE UP AIR SHALL BE PROVIDED TO LAUNDRY ROOMS PER 2007 CALIFORNIA C.M.C •. NOTE THAT EXHAUST FANS SHALL NOT DISCHARGE TO THE EXTERIOR OF THE BUILDING CLOSER THAN 3' FROM ANY EXTERIOR OPENING. 18.-THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 7.75 INCHES BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR SCREEN DOOR, DOES NOT SWING O\'ER THE LANDING. 19.-ALL BATHROOM CIRCUITING SHALL BE EITHER: A) A 2D AMPERE CIRCUIT DEDICATED TO EACH BATHROOM, OR B) AT LEAST ONE 20 AMPERE CIRCUIT SUPPLYING ONLY BATHROOM RECEPTACLE OUTLETS. 20.-ALL ABS AND PVC PIPING ANO FITTINGS SHALL BE ENCLOSED WITHIN WALLS AND FLOORS COVERED WITH "TYPE X GYPSUM BOARD"OR SIMILAR ASSEMBLIES THAT PROVIDE THE SAME LEVEL OF FIRE PROTECTION. PROTECTION OF MEMBRANE PENETRATIONS IS NOT REQUIRED. 21.-JCINTS AND OPENINGS, ANGULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY. OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. EXISTING ZONING: R-15.000/0S • PROJECT DOES NOT PROPOSED ANY CHANGE GROSS SITE AREA: 2 ACRES EXISTING/PROPOSED LAND USED: R4/0S • PROJECT DOES NOT PROPOSED ANY CHANGE YEAR CONSTRUCTED: BEFORE 1994 FIRE PROTECTION:FIRE SPRINKLERS REQUIRED BY CITY OF CARLSBAD FIRE DEPARTME PROJECT SCOPE • PROPOSED GARAGE CONVERSION/ ADU 932 SQ.FT. • CONVERSION TO INCLUDE: • 1 BEDROOM w/ BATHROOM • WALK IN CLOSET • LIVING ROOM • KITCHEN GENERAL CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING BUILDING CODES AND ASSOCIATED CITY OF CARLSBAD AMENDMENTS: -2019 CALIFORNIA RESIDENTIAL CODE -2019 CALIFORNIA BUILDING CODE -2019 CALIFORNIA GREEN BUILDING STANDARDS CODE -2019 CALIFORNIA ELECTRICAL CODE -2019 CALIFORNIA MECHANICAL CODE -2019 CALIFORNIA PLUMBING CODE -2019 CALIFORNIA FIRE CODE -2019 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS PARCEL MAP -,\ ....-,;;-... -..,, .. ~\ ' . ' @ • ' 207-06 SHT20F2 i@ MAP5524•1-10Ll.Y BRAE !cSThTES HAP 26'!7 -CAAl,.SBAO HISHI..ANOS flOS S3S,JSS8,+aH.1$842.1~1>3 VICINITY MAP -1~-'i' CDP 2022-0039 & . ' 0ESl(J;~ tlf lfil:!.!ilbl§!>' SINGLE FAMILY DETACHED 3,634 SQ.FT. AREAS OF WORK GARAGE CONVERSION/ADU : • GARAGE CONVERSION/ADU 932 SQ.FT. • ROUGH PLUMBING • ROUGH ELECTRICAL • OTHER AREAS SHOWN IN SITE ANO PLAN NOT INCLUDED IN BUILDING PERMIT APPLICATION • SECTION R106.2 LOT COVERAGE • EXISTING BUILDING COVERAGE: 3,634 SQ.FT. (3.65%) • PROPOSED A.D.U. COVERAGE: • TOTAL BUILDING COVERAGE: • EXISTING LANDSCAPE AREA: • EXISTING HARDSCAPE AREA: • EXISTING UNIMPROVED AREA: 932 SQ.FT. (.94%} 4,566 SQ.FT. 4.58% 10,538 SQ.FT. 10.58% 10,625 SQ.FT. ·10.67% 73,862 SQ.FT. 74.17% REVISION / ISSUED: ~ PLAN PREPARER INFO ~ EXISTING LAND USE DESIGNATION & EXISTING ZONING DESIGNATION ffi UPDATED SHEIT LIST ffi CDP PERMIT NUMBER Sheet SHEET NAME No. & ST SITE PLAN G-"1:b; l--'' A 11 A1 EXISTING FLOOR PLAN A2 EXISTING ELEVATIONS A3 EXISTING ROOF PLAN A4 DEMO FLOOR PLAN A5 PROPOSED FLOOR PLAN A6 PROPOSED ELEVATIONS A7 PROPOSED SLOPE ELEVATION ADDRESS: 3800 ALDER AVE CARLSBAD, CA 92008 APN :207-063-24-00 ,, 011 \\ II \\ D" ,\ \E" ll ,, F'' " ,, .. H ,, PROJECT: CASKEY RESIDENCE GARAGE CONVERSION/ADU DATE: SCALE: 09/08/2022 1/32" = 1' -O" SHEET: WALL LEGEND EXISTING 2X4 WALL NEW 2X4 INFILL DEMO WALL NEW 2X4WALL NEW2X6WALL 22'-1 O" [27 4"] (E) 7 GALLON TANKLESS WATER HEATER {E) GARAGE 932 SQ.FT. {E)ELECTRJC SUB PANEL 100 MAIN (E)DOOR 96"x 34" ENTRY 22'-1 O" [274"] "1<------1~~~==================13Z~bhlIF==================~""'~~~dZ.__j-------"k ,l 11190~" 1 ,I, EXISTING GARAGE PLAN SCALE g" = 1' -O" CDP 2022-0039 & DESIGN &, BUILD -- SINGLE FAMILY DETACHED 3,634 SQ.FT. AREAS OF WORK GARAGE CONVERSION/ADU : • GARAGE CONVERSION/ADU 932 SQ.FT. • ROUGH PLUMBING • ROUGH ELECTRICAL • OTHER AREAS SHOWN IN SITE AND PLAN NOT INCLUDED IN BUILDING PERMIT APPLICATION • SECTION R106.2 LOT COVERAGE • EXISTING BUILDING COVERAGE: • PROPOSED A.D.U. COVERAGE: • TOTAL BUILDING COVERAGE: • EXISTING LANDSCAPE AREA: • EXISTING HARDSCAPE AREA: • EXISTING UNIMPROVED AREA: REVISION/ ISSUED: ffi CDP PERMIT NUMBER ADDRESS: 3,634 SQ.FT. (3.65%) 932 SQ.FT. (.94%) 4,566 SQ.FT. 4.58% 10,538 SQ.FT. 10.58% 10,625 SQ.FT. 10.67% 730862 SQ.FT. 74.17% 3800 ALDER AVE CARLSBAD, CA 92008 APN :207-063-24-00 PROJECT: CASKEY RESIDENCE GARAGE CONVERSION/ADU DATE: SCALE: 09 I 08 I 2022 ~" -1' O" 8 -- SHEET: -------------+ 9'~ f-------------------j IJ] .. . . I I I I I I I I I I Lc_ _ _j_ _______________ ~_c_:.~.:_:L------------------'~-'--'--'--1~1~_,1_-'-'-' ! _________ • O'-~ EXISTING NORTH-EAST ELEVATION SCALE J" = 1' -O" -------------+ 12'-07:::::!!!!!,JJI' . , ' ' ' n . ' I ' -T ' i I : ! : ' I ' ' ' ! i i ' : ' I ' ' ' i i i ' ' I ' i I I ' i i ' ' : i i i : : ; I ' i : ' : ' ' ! ' ' ' ' ' ' ' ' ' i ' : ' i ' ' I ' ' ~ ' i I ' i ' : i . : ' : ' : : : ' I : I i i I I : ' I ' ' ' ' ' ' ' I ' ' ' : ! ' I i I ' I : I ' I ' ' I i I I I ' I ' I ' ' I ' ' ' ' ' I ' ' I ' i ' I I I i I : i : i : ' I I ' ! I , I ' I ' I ' I ' ----------------.. s·~ " " .. .. • . . · . ·. •. . ·. ' . .. ,, . ,. . ' ,• ' " . . • •, .. ' . .., •, . • ,-, . .. . " ,• ... : .. '. ,. . .. . I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ---______________ + 0'-0~ EXISTING SOUTH-WEST ELEVATION SCALE ¾" = 1' -O" -------------------··--------- (E)DDOR 96"• 34" (E)TEMP ED GLASS SLIDIN V'J)NDOW 72 4S" EXISTING NORTH-WEST ELEVATION SCALE i" = 1' -O" (!'.)TEMP ED GLASS SLIDIN MNDOW " ~- EXISTING SOUTH-EAST ELEVATION SCALE ¾" = 1 ' -O" CDP 2022-0039 & - DES,IGN &· BUILD SINGLE FAMILY DETACHED 3,634 SQ.FT. AREAS OF WORK GARAGE CONVERSION/ADU : • GARAGE CONVERSION/ADU 932 SQ.FT. • ROUGH PLUMBING • ROUGH ELECTRICAL • OTHER AREAS SHOWN IN SITE AND PLAN NOT INCLUDED IN BUILDING PERMIT APPLICATION • SECTION R106.2 LOT COVERAGE • EXISTING BUILDING COVERAGE: • PROPOSED A.D.U. COVERAGE: • TOTAL BUILDING COVERAGE: • EXISTING LANDSCAPE AREA: • EXISTING HARDSCAPE AREA: • EXISTING UNIMPROVED AREA: REVISION/ ISSUED: fil CDP PERMIT NUMBER ADDRESS: 3,634 SQ.FT. (3.65%) 932 SQ.FT. (.94%) 4,566 SQ.FT. 4.58% 10,538 SQ.FT. 10.58% 10,625 SQ.FT. 10.67% 73,862 SQ.FT. 74.17% 3800 ALDER AVE CARLSBAD, CA 92008 APN:207-063-24-00 PROJECT: CASKEY RESIDENCE GARAGE CONVERSION/ADU DATE: 09 I 08 I 2022 SHEET: SCALE: 1" -1' O" 4 -- \\ t\ C n I I LJ lj I I I I I I I ' I l I I I I I I I I ' ! I I i IL L ---=-~ FIRE RESISTANCE CLASSIFICATION: CLASS A ASPHALT SHINGLES Section 150.1 excerpts below are from the 2019 Building & Energy Efficiency Standards If an ADU is built over an existing garage, this is considered an addition to an existing structure. Not new construction. PV solar is not required. Section 150.1(c) 14 3:12 3:12 n I I I I LJ lj I I 1 I I , ' L~_lj EXISTING ROOF PLAN SCALE i" = 1' -O" CDP 2022-0039 £ DESIGN & BUILD SINGLE FAMILY DETACHED 3,634 SQ.FT. AREAS OF WORK GARAGE CONVERSION/ADU : • GARAGE CONVERSION/ADU 932 SQ.FT. • ROUGH PLUMBING • ROUGH ELECTRICAL • OTHER AREAS SHOWN IN SITE AND PLAN NOT INCLUDED IN BUILDING PERMIT APPLICATION • SECTION R106.2 LOT COVERAGE • EXISTING BUILDING COVERAGE: • PROPOSED A.D.U. COVERAGE: • TOTAL BUILDING COVERAGE: • EXISTING LANDSCAPE AREA: • EXISTING HARDSCAPE AREA: • EXISTING UNIMPROVED AREA: REVISION/ ISSUED: 3,634 SQ.FT. (3.65%) 932 SQ.FT. (.94%) 4,566 SQ.FT. 4.58% 10,538 SQ.FT. 10.58% 10,625SQ.FT. 10.67% 73,862 SQ.FT. 7 4.17% & EXCEPTION FOR PV SYSTEM fil CDP PERMIT NUMBER ADDRESS: 3800 ALDER AVE CARLSBAD, CA 92008 APN:207-063-24-00 PROJECT: CASKEY RESIDENCE GARAGE CONVERSION/ADU DATE: 09 I 08 I 2022 SHEET: SCALE: ~" -1' O" 8 -- WALL LEGEND 18888&1 r----7 L ____ _j L ~-:,~<<:<<<I EXISTING 2X4 WALL NEW 2X4 INFILL DEMO WALL NEW 2X4WALL NEW2X6WALL 2'-6" I [30"1 I L1 6' [72"] I I I I I I I I i DEMO PLAN KEY NOTES 1. MAKE OPENING FOR NEW I/VINDOW 2. REMOVE EXISTING WINDOW AND INSTALL NEW WINDOW 3. REMOVE EXISTING GARAGE DOOR 4. REMOVE EXISTING GARAGE DOOR (E) GARAGE 932 SQ.FT. DEMO GARAGE PLAN SCALE ~" = 1' -O" CDP 2022-0039 & DESIGN &i BUILD ---- SINGLE FAMILY DETACHED 3,634 SQ.FT. AREAS OF WORK GARAGE CONVERSION/ADU : • GARAGE CONVERSION/ADU 932 SQ.FT. • ROUGH PLUMBING • ROUGH ELECTRICAL • OTHER AREAS SHOWN IN SITE AND PLAN NOT INCLUDED IN BUILDING PERMIT APPLICATION • SECTION R106.2 LOT COVERAGE • EXISTING BUILDING COVERAGE: • PROPOSED A.D.U. COVERAGE: • TOTAL BUILDING COVERAGE: • EXISTING LANDSCAPE AREA: • EXISTING HARDSCAPE AREA: • EXISTING UNIMPROVED AREA: REVISION/ ISSUED: fil CDP PERMIT NUMBER ADDRESS: 3,634 SQ.FT. (3.65%) 932 SQ.FT. (.94%) 4,566 SQ.FT. 4.58% 10,538 SQ.FT. 10.58% 10,625 SQ.FT. 10.67% 73,862 SQ.FT. 74.17% 3800 ALDER AVE CARLSBAD, CA 92008 APN :207-063-24-00 PROJECT: CASKEY RESIDENCE GARAGE CONVERSION/ADU DATE: 09/08/2022 SHEET: SCALE: ~ .. -1' O" 8 -- 23'-8" r.,-.. .A"] . .. RINNAI {RUS65EJ _-, REU-KCM2025W-US (199 00 BTU) !'i '-!'i" 6'-7" ?,0'-7" l41 o 1 7'-?" GAS 1_..,NK LESS ;>.:•_:,;-;. ·f: ·.· .·•-: _'CY·'•" ., ·-i ·:_ ·--, ... ,· ···i-· ::,_:\'./.C ··' ·:_-._,•_.,: •~·--.. / <,'': :· ·. ·, _,. · · · ·.<-:'><"-;: ,< f<;\>>·· ·' . ;'.\ 5'-5' ,--,,--,,----,,--,,-¼---,I-.• ,.-:-'/./ [65" 2'-6" [30") . ' / 1>.:i_ tempered glass / // shower door @ 6'-7" 9'-7" l I" J [115"] M.BATH 105 SQ.FT. ® . 3' 5" [41 ") r;c Q n;w ::~ l:TERl~R ;::bing woll ® • •"-f.4) ~ • , w/ r-15 batt insulation ~ FRIDGE 36" 2'-6" [30") ® 1,,,_ _____ _:.:W:::"'-:::'A=;,N~DF~Loo;:;;;R;,:sT~c•:;,;'.':;;c_;::.RA::::n::.:NG7 1),J8~'ii!-9:{r',' ---------:=-:::;---------"1\I '.'"'.J if------+,.rl~~-;?,,i..,';-----r.! (J) ,..._! 10'-9" [129"] & r--- 1 I 30"x36" EV Parking/ Charging Station M.BED ROOM / ' 152 SQ.FT. I. ..,. I 1' ;, " ~ I •. ; •; [i•:i > :, /". I' l >-AC LE\/EL 2 --1,,1 lf! .. ,:s,•.··•·····1 / ® . . l -50 J . u [7.::·J CONCRETE LANDING •, @ .. p;:::::::, ===!~ < L/ ,, ~ 9'-11" / [119"] .. W.I.C. 64SQ.FT. :< ' ,, o< .. / / / ~~ new 2x6 EXTERIOR woll __/ w/ r-15 batt insulation WALL AND FLOOR STC & ICC RA11NG OF NO LESS THAN 50. 7'-'.i" [1:$/ 'J . I/ ' 1 .• / 1: . [475"] PROPOSED GARAGE/ADU PLAN SCALE i" = 1' -O" WALL LEGEND 1&§§§§1 EXISTING 2X4 WALL NEW 2X4 INFILL DEMO WALL NEW 2X4WALL NEW2X6WALL SCHEDULES DOOR SCHEDULE MARK DIMENSION TYPE TEMPERED CD 33" X 91" SWINGING N 2 28" X 80" SWINGING N 3 27" x80" SWINGING N 4 77"x 80" Bl-FOLD N 5 72"x80" SLIDING y 6 80"x80" SLIDING y 7 30"x80" POCKET N WINDOW SCHEDULE NOTES MARK DIMENSION TYPE TEMPERED QTY. ENTRY A 72" x48" SLIDING y 1 ' 30" x48" SLIDING y 2 SOLID CORE I B SOLID CORE I C 24" X 56" HUNG y 2 LAUNDRY PATIO PATIO MASTER ROOM 22'-10" [27 4") 6'-8" ll:$U J KITCHEN 154 SQ.FT. LIVING 194 SQ.FT. ® l 8U"J CONCRETE LANDING ?()' [i4U"J . 3' "" [41'1'] . -'1__ __ ..Jl_ 1" [j"] 1· 6'-7" [79"] DINING 98 SQ.FT. CD ENTRY I © © ?' 8' ?' ::I()" ?'-7" [24"] l:.:ll J . r ··•··· I(• (' •• ' ,\. . -:_·_ i ; 9'-1" [109"] A 23'-8" ---· [284"] l-1'---➔S&'-~4~",l--'rC~,O~CRETE ';/ L NDING . . 1, 2'-11" l 35"J I ' [7 "] . CDP 2022-0039 & DESIGN & BUILD -. -- SINGLE FAMILY DETACHED 3,634 SQ.FT. AREAS OF WORK GARAGE CONVERSION/ADU : • GARAGE CONVERSION/ADU 932 SQ.FT. • ROUGH PLUMBING • ROUGH ELECTRICAL • OTHER AREAS SHOWN IN SITE AND PLAN NOT INCLUDED IN BUILDING PERMIT APPLICATION • SECTION R106.2 LOT COVERAGE • EXISTING BUILDING COVERAGE: • PROPOSED A.D.U. COVERAGE: • TOTAL BUILDING COVERAGE: • EXISTING LANDSCAPE AREA: • EXISTING HARDSCAPE AREA: • EXISTING UNIMPROVED AREA: REVISION/ ISSUED: 3,634 SQ.FT. (3.65%) 932 SQ.FT. (.94%) 4,566 SQ.FT. 4.58% 10,538 SQ.FT. 10.58% 10,625 SQ.FT. 10.67% 73,862 SQ.FT. 74.17% LOCATION EV PARKING/CHARGING STATION LOCATION OF TANK LESS WATER HEATER CDP PERMIT NUMBER ADDRESS: 3800 ALDER AVE CARLSBAD, CA 92008 APN:207-063-24-00 PROJECT: CASKEY RESIDENCE GARAGE CONVERSION/ADU DATE: SCALE: 09 I 08 I 2022 ~II -1' O" 8 -- SHEET: ----------------------------------------------------------------------------------------------------------------------------------------------------, ... _. 1( r ---'----~--------------' __ ,, ______ j____ ·----·---~----'--··· --,-C------· -,-----------'---------~'--·· ------j _____ , ___ -·-··-···-··--' i --, --···' ~------·-··• ··--· -~-_: __ : :_,. , __ : __ ,_ ___ ' '--~ -. ______ ... ' - (N) E ERED SLIDN LASS ' 2 O" (N) I::. RED SLI IN LASS ' ' ' ,. . ( TEMPl":RE G~~ SINGLE HUNG PROPOSED NORTH EAST ELEVATION SCALE J" = 1' -O" F·=----=--~=-· =· ~-=---c--.--="""-·=---=------s---~----r----=-=-=-=--·--'""--,,,.,..,.=·=-=--=-=----=---,----,_._ ,,~-,~--=-~-=--,-~---,--~.,-=-~-·=--,=-~~~=-=--'""--=-===--=--=--,-,,-,-,,===,------------------+ 12·-01~ ' . -;------'-,L, ~--'---=-~-~~---------= --~-~~~-------'-c---~-'--'"·-·. -·. ~-~--'-c-~-~~-----J -------~' __ ;_~_ I,·•··• '-c' =--····•·-•-=--• "--,-~ ~---------~-'" · .. ; '-,' '--•-·-' --=·-~----. ' . ' ' -•," •··• , •, ,------------•,------, •·---••" •-,-------•--'-••·•• 0 , '._ • ., •• , •• • _ ... , ___ """"'",',', '.,e-•--•----•, •e-'--•' •·•~----•-""-- • ' ' ' 1 ' ' ' ' '" ,,, •·---------,--~----.. ·----•·-~-,----.. ··,-··-----"----~~---· -· ,_;_ -------'~---·-----~---. ------,---'-;-- PROPOSED SOUTH WEST ELEVATION SCALE J" = 1' -O" (~DOOR s1-x34" (E)'fEMt>E D GLASS Si.lDING VINOOW 72• 4$" PROPOSED NORTH WEST ELEVATION SCALE J" = 1' -O" ~-,:::.::...:::::.::------------------------------------+ 12'-0~ • \N)TEM?ERED GLASS· SLIDING WINDOW J0"x48" (N)TEMPEREO GLASS ' SLIDING W1Nll0W . 30"x 48" PROPOSED SOUTH EAST ELEVATION SCALE J" = 1' -O" CDP 2022-0039 £ SINGLE FAMILY DETACHED 3,634 SQ.FT. AREAS OF WORK GARAGE CONVERSION/ADU : • GARAGE CONVERSION/ADU 932 SQ.FT. • ROUGH PLUMBING • ROUGH ELECTRICAL • OTHER AREAS SHOWN IN SITE AND PLAN NOT INCLUDED IN BUILDING PERMIT APPLICATION • SECTION R106.2 LOT COVERAGE • EXISTING BUILDING COVERAGE: • PROPOSED A.D.U. COVERAGE: • TOTAL BUILDING COVERAGE: • EXISTING LANDSCAPE AREA: • EXISTING HARDSCAPE AREA; • EXISTING UNIMPROVED AREA: REVISION/ ISSUED: ffi CDP PERMIT NUMBER ADDRESS: 3,634 SQ.FT. (3.65%) 932 SQ.FT. (.94%) 4,566 SQ.FT. 4.58% 10,538 SQ.FT. 10.58% 10,625 SQ.FT. 10.67% 73,862 SQ.FT. 74.17% 3800 ALDER AVE CARLSBAD, CA 92008 APN:207-063-24-00 PROJECT: CASKEY RESIDENCE GARAGE CONVERSION/ADU DATE: SCALE: 09 / 0812022 1" -1' O" 4 -- SHEET: -------------------~--="~~-- + 12'-07'' ·,-· ' ' ',-· ·---···--··-,-·-·-'-•·---·• ,·•-· . '' -_--'. '. -•, ____ .,,: ________ ~, :.•; •,-· •. , ,,.,_,' ___ ; _____ , __ ,_,_•-.i';,·_' __ : __ 'I' '-'-------'--''----'----'--------'-' • ---·•-<··--·· -: ._,--'--. "' -"---'----'------J'--~-~--. ·--------· -'-' -"-' ~-----'--'---'----'----'----'----'----" ___ j ·,-" _ .. ___ .' :_1 ·---"" ________ , -~--,~~-,--{ ' -' ' ' '----· ----- ~-----·· ·······-----·--------··---,.--~--.. ! ___ : ': __ : ---- + 8.82' • ·.: i IJ I a, ,_ cr,ss + 0'-00" PROPOSED NORTH EAST TOP SLOPE ELEVATION SCALE 1~" = 1' -O" CDP 2022-0039 ffi DESlGN &IBUllD SINGLE FAMILY DETACHED 3,634 SQ.FT. AREAS OF WORK GARAGE CONVERSION/ADU : • GARAGE CONVERSION/ADU 932 SQ.FT. • ROUGH PLUMBING • ROUGH ELECTRICAL • OTHER AREAS SHOWN IN SITE AND PLAN NOT INCLUDED IN BUILDING PERMIT APPLICATION • SECTION R106.2 LOT COVERAGE • EXISTING BUILDING COVERAGE: • PROPOSED A.D.U. COVERAGE: • TOTAL BUILDING COVERAGE: • EXISTING LANDSCAPE AREA: • EXISTING HARDSCAPE AREA: • EXISTING UNIMPROVED AREA: REVISION/ ISSUED: fil CDP PERMIT NUMBER ADDRESS: 3,634 SQ.FT. (3.65%) 932 SQ.FT. (.94%) 4,566 SQ.FT. 4.58% 10,538 SQ.FT. 10.58% 10,625 SQ.FT. 10.67% 73,862 SQ.FT. 74.17% 3800 ALDER AVE CARLSBAD, CA 92008 APN:207-063-24-00 PROJECT: CASKEY RESIDENCE GARAGE CONVERSION/ADU DATE: SCALE: 09 I 08 I 2022 ..;1_., -1' O" 16 -- SHEET: