Loading...
HomeMy WebLinkAboutAS130010; 2290 COSMOS CTCity of Carlsbad Sprinkler Permit Job Address: 2290 COSMOS CT Permit Type: SPRINK Parcel No: 2130504400 Lot#: 0 Reference No.: PC#: Project Title: VIASAT T.I. T.I. Applicant: EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY SAN MARCOS, CA 760-310-6122 Fees($) Add'I Fees ($) 268 0 Permit No: AS 130010 Status: PENDING Applied 1/23/2013 Approved: Issued: Inspector: Owner: GRANDONA INVESTMENT ASSOCIATES LP 2610 HARRISBURG AVE FREMONT CA Total($) Balance($) 268 0 ::i> ~ --~ 0 0 ---0 1:qc:a I Fire & Building f Products Technical Servlcea: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series EC·B -8~0 K-factor Extended Coverage (Light HazardJ Pendent and Recessed Pendent Sprinklers General Description The Series EC..S Extended Coverage P.endent Sprlnklera are decorative glass bulb eprln:klef'II designed for use In light hazard occupancies. They are Intended for use in,automatlc sprlnlder systems designed iruccordance with standard installation rules (e.g., NFPA 13) lor a maximum COYerage area of 400 ft2 (37,2 n,2), as.compared.to the maximum coverage area of 225 ft2 (20,6 m2) for standard:coverage sprin- klen; used in-light hazard occupancies. The recessed verwlon ol the EC-8, In- tended lor use in areas with a finished celling; UHi either the two-piece Style 30 oi: 40 Rec:eeeed Eacutcheon. The Style 30 R-,iud Escutcheon-pro- vides 1.1p lo 1/2 inch-tt_2,7 mm) of total adjustment from the flush pendent po- sition, whereas, the Style 40 provides ::~rf~~1~! ~~ ;!,:'e~8~:a::: The adjustment provided by the Re• cessed Escutcheons reduces the ac- curacy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utllfzed to extend the fife of copper alloy sprinklers beyond that which would otherwise be ob· talned when e,cposed ta corrosive at- mospheres. Although corrosion resls- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING' that provides cautions with respect to handling and fnsta/• lat/on or sprinkler systems and com- pcinents. Improper handling and in-stallation can pennanently damage a sprinkltu system or its compc,- nents and cause the sprir«Jer to fall to operate In a fire situation or cause it to operate prematurely. Page 1 of e tan! coated sprinklers have passed the standard corrosion tests of the ·appli- cable approval agencies, the testing is not representative af all possible cor• rosive atmospheres. Consequently, It Is recommended that'the end user be consulted with respect to1he suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, · concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Ser/es EC-8 Extended Coverage Sprlnkl11rs describtld hMein must b& inBtalled and maintained In compli• af!Cfl with this documMt, as well as with the applicable. standaids of the National Fire Protection Auoclatlon, In addition to the atandards of any other authoritJBs hawng Jurisdiction. Failure to do MJ may Impair the per• formant:• of th•• delllc-. The owner is responsible for maln/a/n-~~f~ f~=-e:::aV:t:O'::fti'!: The Installing contractor or sprinlc/er manufacturer should be contacted with any questions. Model/Sprinlcler Identification Number TY4232 • Pendent, I.OK TY-4232 is a redeslgnation for C4232. JANUARY, 2005 Technical Data Approvals UL and C-UL Listed. FM and NYC Ap· proved. (Refer to Table A for complete approval information Including corro- sion resistant status. The approvals apply to the service conditions lndl· cated In the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thrnd Connection 314 inch NPT Discharge Coefficients K = 8.0 GPM!pst112 (115,2 LPM/bar112) TFP223 ) ) P ... 2of8 TFP223 Componenta: 1 • Frame 2. 8iltlon 314• .. ESCt/TOHEON Pl.ATE 3 • Sealing"-1,bly 4'· Bull 5 • Compranion Si:rew 6· Detleclor" " Temperature rating is lnclcatedonDstleclor. *" Pipe thread comectlon&perlSO 7/1canbep10111ded on special request, :' LmNPT SEATI1rNG7E 3 1 2-1/8' . • . 112• f_l(S4,0mm) 4 (12,7mm) NOMINAl. 1-7/16' S MAKE-IN (36,5 mm) e• FIGURE1 SERIES EC-8 (TY-4232} EXTENDED COVERAGE PENDENT SPRINKLERS SPfllNKt£R FNSH (SN Noa 4) HAZARD TYPE Tl:MP, BULB NATURAL I CHROME ~WHITE" UQUIO BRASS PLATED LYESTER UGHT PENDENT 1'35'F/SrC Orange 155°F/68'C Red 1,2, 3,5. Rew to Tabla 8 lor UL and C-OL SenaltlYlty Rating REC. PENDENT t35"F/SrC Orange and wt8tyle30 Eac. 1'551F/68'C Rad 1,2, 3,5 Refw lo Tabla C for FIii S.nalt1Yllyflatlng REC. Pl!HDENT 135"Ft57"C Orange wl8tyle40~ 155'F/68"C Red 1,2,5 NOTO: 1. Usled,by Underwrttara Laboratories, Inc. (UL). 2. Ul!&d'by Underwrttara Labora!Olles, Inc. for un In Canada (C-lJL). 3. Appl'O'led by Factory M~ RNearch Corporatlon (FM). 4. Where Polyester COllled Sprinklers are noted IOt>e UL and C-{JL Listed, 1he sprinklers are UL and C-UL Lls1ed as CotroslOn Resistant Sprinklers. 5. Appl'CNlld by the City of New York under MEA 113-04-E. "Frame and Deflector only. Uatlnga and approvals apply lo color (Special Order). Temperature Rating• 135'F/57'C and 155°F/68°C Flnlah Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Phy1ieal Characteristics Frame . . . . . . . . . . . . . Bronze Button . . . . . . . . . . . . . Bronze Sealing Assembly . . . . . . . . . . . . . . . Berydlum Nickel w/Teflont Bulb . . . . . . . . Glass (3 mm dia.) Compression Screw . . . . . . . . . . . . . . . . . . . . . . . . . Bronze Deflector . . . . . . . . . . . . Brass t Registered trademark of DuPont TABLE A LABORATORY t./STINGS AND APPROVALS (R«tlr to tlN O.lgn Crtt.rla Section) Operation The glass bulb contains a fluid tha1 expands when exposed 10 heat. When the rated temperature Is reached, the fluid expands sufficiently 10 shatter the glass bulb, anowing the sprinkler to activate and flow water. Design Criteria. The Serles EC-8 Extended Coverage Pendent Sprinklers must only be In- staled in accordance with the applica-ble UL and C-UL Listing or FM Ap-proval requirements as indicated below. Only the Style 30 or 40 Re-cessed Escutcheon is to be used for recessed fnstallation, as applicable {Ref, Table A, 8, and C)._ UL and C-Ul Llatlng Requirements 1. The Serles Ee-a Sprinklers may be used for the coverage areas shown in Tabl&D, ~ on malntalning the minimum specified flow rate as a function of coverage area and haz. ard group for all of the sprinklers In the design area. 2. With respect to heat sensitilllty, the Series EC-8 Sprinklers can be used with unobstructed construction con-sisting of flat, smooth ceilillgS (in- cluding bar joists) wtth a maxlmum pitch_ of one In six as defined and. pennltted by NFPA 13. 3. The minimum allowable spacing be- ) TFP223 135'F 155'F AREA STYLE 16 X 16 Pendent QR QR 16x16 Style30 Recessed QR QR 16 X 16 Style 40 Recesaed QR QR 16x 18 Pendent QR QR 16x 18 Slyte 30 Recesaed QR SR 18 x 18 Style 40 Recessed QR SR 20 x 20 Pendent QR SR 20 x 20 Style 30 Recessed QR SR 20 x 20 Style 40 Recessed SR SR QR:QuickRe&p()f'll8 SR: Standaid Aespalse NIA: Not Applcable TABLES SENSmlllTY RA TING FOR UL AND C-UL LISTING OF SERIES EC-a SPRINKLERS 135'F 155'F AREA STYLE 16 x 16 Pendent QR QR 16 X 16 S1yle 30 Flecesaed QR WA 16 X 18 Style 40 Recessed NIA NIA 16 X 18 Pendent QR QR 18 x 18 Style 30 Recesaad QR NIA 18 X 18 S1yle 30 Recessed NIA NIA 20 X 20 Pendent QR QR 20 x 20 Style 30 Rec:eseed QR WA 20 X 20 Style 40 Recessed NIA NIA QR:QuickResponae SR: Standard Response NIA: Nol Applcable TABLEC SENSITWITY RATING FOR FM APPROVAL OF SERIES EC-8 SPRINKLERS tween !he Series EC-S Sprinklers, to prevent cold soldering, is 8 feet (2,4 m). 4. TheSeriesEC-8Sprlnklersaretobe Installed In accordance with all other requirements of NFPA 13 for ex-tended coverage pendent sprin- klers. FIi Approval Requlnimenta The Series EC·B Extended Coverage Sprinklers are to be Installed In ac- cordance with the applicable Factory Mutual Loss Prevention Data Sheet. Information provided In the FM Loss Prevention Data Sheets relate to, but are nol limited to, hydraulic design, celfing slope and obstru,;tions, mini-mum and maximum allowable spacing, and deflectorsto ceiling distance. P ... 3of8 Installation The Serles EC-8 Sprinklers must be instaNed in accordance with 1he follow- ing Instructions: NOTES Do not insla/1 any bulb type sprinkler If the bulb is cracked or there Is a loss of liquid from t/16 bulb. With the sprinkler 116/d horizontally; a smsll sir bubble should be present. The diameter of the air bubble is approximately 1/16 inch {1,6mm). A leak tight 314 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. {13,4 to26,8 Nm}. A maxi- mum of 30 ft.lbs. (40,7 Nm) of torque Is to be-used to Install sprinklers. Higher leve/B of torque may distort the sprinkler Inlet wltb consequent leak· ags or /mpairn11mt of. the sprinkler. Do not attempt to compensate for ln- 1ufflclent adjustment of an Escutcheon Plate by under-or over-tightening the Sprinkler. Reacfust .thtt position of the sprinkler fitting to suit. Step 1. The sprinkler must be Installed with the deHector parallel to the mount• Ing surface. Pendent sprlnldera must be inatalled In the pendent position. Step 2. After Installing the Style 30 or 40 mounting plafe (or other escutch- eon, as applicable) over the sprinkler pipe threads, and wllh pipe thread 1ealant applied to the pipe threads, hand tighten the sprinkler Into the sprinkler fitting, Step 3. Wrench tighten pendent sprin-klers using only the W-Type 3 (End A) Sprinkler Wrench. Wrench tighten the r.ecessed pendent sprinklers using only the W-Type 4 Sprinkler Wrench. The wrench recess of the applicable sprlnkler wrench (Ref. Figure 4 and 5) is to be applied to the sprinkler wrench flats (Ref. Figure 1), ) Page 4 of8 DESCRIPTION TY4232 (Kal.0) PENDENT 1 ft. • 0.3048 m 1 ft2 " 0.093 ,n2 1 gpm = 3.785 1pm 1 p&I = 0.06895 bar 1 gpmlft2 s40,74 mm/min AREA 16x f& 18x ta 20x20 TABLED G~ ~ ~ ~ 33 ~ ~ ~ FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 112t118" (12,7"3,2mm) FACE OF SPRINKLER FITTING 1/2' (12,7 mm 1/4" (6,4 mm) l\~-_.i_~- MOUNTING SURFACE CLOSURE 1-1/4" (31,8 nvn 1'(25,4mm) FIGURE2 SERIES EC-I RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWo-PtECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON_ 9/16±1/4' (14,3.S,4 mm) FACE OF SPRINKLER RTTING ~ 2·1/4" DIA.~ h-,~ 314• (19, 1 nvn 1/4' (6,4mm) I\ ~--,_.i_c----r MOUNTING SURFACE CLOSURE 1-5/16' (33,3 mm) 13/16" (20,e mm) FIGURE3 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON TFP223 "FITTING SIDE" TOWARDS SPRINKLER ATTING 7 ENCH ECESS ND"A")' RGURE4 W•TYPE 3 SPRINKLER WRENCH fr~51~~~: ® , ...... --' ! L.., . ', ¢:JG) t_ ____ j _, FIGURES WRENCH LUGS W•TYPE 4 RECESSED SPRINKLER WRENCH Care and Maintenance The Series EC-8 Sprinklers must be maintained and servlced In accord- ance with the following Instructions: NOTE Before closing a fire pro118ctlon system main control valve for maintenance worlc on the fire protection system that It controls, permission .to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected-by this action must be no-tified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi• fled sprinklers must be replaced. Sprinklers that have been exposed to ) TFP223 corrosive products of combustion, but have not operated, should be replaced If they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft brlsde brush. Care must be exercised to avoid dam-age to the .sprinklers • before, during, and after Installation. Sprinklers dam• aged by dropping, striking, wrench twlsVslippege, or the like, must be re• placed. Also, replace any sprinkler that has a cracked bulb or that has lost fiquid from its bulb. (Rel. Installation Section). Frequent visual Inspections are rec-ommended to be Initially performed for corrosion resistant coated. sprinklers, after the lnstaHatlon has been com• pleted, to verify the Integrity of the cor- rosion resistant coating. Thereafter, annual Inspections per NFPA 25 should suffice; however, Instead of In-specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term Integrity of the corrosion resistant coaling, as It may be affected by the corrosive conditions present. The owner Is responsible for the in• apec:tion, testing, and maintenance of their fire protection system and de· vices .In compliance with this docu- ment, as wall as with the applicable standards of the National Fire Protec-tion Association (e.g., NFPA 25), In addltlon to the standards of any other authorities having jurisdiction. The In-stalling contl'actor or sprinkler manu• lacturer should be contacted relative to any questions. It Is recommended that automatlc sprinkler systems be inspected, tested, and malntalned by a qualified Inspection Service In accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects In material and work- manship when paid for and property Installed and malntalned under normal use and service. This warranty will ex- pire ten (10) years from date of ship-ment by Tyco Fire Products. No war- ranty Is given for product& or components manufactured by compa- nies not affifiated by ownership wlth Tyco Fire Products or for products and components which have been subject to misuse-, Improper Installation, corro- sion, or which have not been installed, maintained, modified or repaired In ac- cordance with applicable Standards of the National Fire Protection Associa-tion, and/or the standards of any other Authorities Having Jurisdiction. Mate-rials found by Tyco Fire Products to be defective shall be either repalred or replaced, at Tyco Fira Products' sole option. Tyco Are Products neither as- sumes, nor authorize& any person to assume for it, any other ot>llgation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE-ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUE:NTlAL DAMAGES, INCLUDING: BUT NOT LIMITED TO L6.BOR CHARGES, RE- GARDLESS OF WHETHER TYCO ARE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND fN NO EVENT SHALL TYCO FIRE PRODUCTS' LI• ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE.. THE E QBEGQfNG WABBAHTY ($ MAQE IN LIEU QE ANY ANQ ALL QTHEB WABffANtJES EKPffESS QR WPPEP fHC'-IIQIHOW4BBANtJE$ Of MEBCHANTABll,UY ANQ EfT- HE$$ EPB A P48t(Cli'-AB PUB-.PJJSE.. PageSofl Ordering Procedure When placing an order, indicate the full product name. Please-specify the Sprinkler Identification Number (SIN), ~u:,~~ ~r~~~~=i:~1~~~~; Part Numbers. Contact your local distributor for avall-abHity. Sprinkler AINmbHH with NPT ThrHd Connections: Specify: TV 4232, (specify temperature rating), Extended Coverage Pendent Sprinkler with (specify finish), PIN {specify). 1Wl'llrC Noni !bu ............. PSN 50-801-1·135 White eo.ted ............. PSN 50-801+135 Whits (RAL9010)" .......... PSN 50-801~135 Chrome Plated ............ PSN 50-801♦135 1u•1Y11-c IM1lnl Bran ............. PSN li0-801-1•155 White eo.ted ............. PSN 50-801+155 ~~~>::: :::::::: ~~ :::::: "Eaalllm Hemisphere sales only'. "-8Nd Escutctwon: Specify: Style (30 or 40) Recessed Escutcheon with (specify finish), PIN (specify). llylelf __ _ C1Yame Plolod ............ PSN 56-705-9-011 -C<>lor Cooled •••••••• PSN 56-705-4-011 -jRAL.9010)' .......... PSN 56-~11 Brua Plolod .............. PSN 58-706-2-011 lltyle40-&cutc11Nn Chtome Pleled ............ PSN 58-700+010 White Color C:O.led ........ PSN 56-700-4-010 WhMe (RAl.9010)" .. , ....... PSN 58-700-3-010 Brua Plated .............. PSN 56-700-2-01 0 •Eas1Bm Hemisphere sales. only. Sprinkler Wl'ench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 4 Recessed Sprinkler Wrench, PIN 56-875-4-001 ) ) Page 8 of I TFP223 TYCO FIRE PRODUCTS, 451 North Cannon Awnue, Lansdale, Pennsylvania 19446 Dyna-lhread0 Full Line Sch-40 Replacement Dyna-Thread' offers the life expectancy of Sch-40 with.superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 • Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. • Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. • The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. • The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. • The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. ®<8>@ Listed Approved Listed • With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Specifications NPS Nominal I.D. Wt. Wt. (H20 FIiied) Pct/ VMift (21 ') Wt/Lift (24') VMift(25'l ln;mm ln;mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1· 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 105t 1¼" 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108] 1½" 1.639 2.290 3.22 44 2115 2418 2515 40 41.6 3.4 4.79 44 959 1097 114~ 2· 2.104 3.050 4.57 30 1921 2196 228i 50 53.4 4.5 6.80 30 871 996 103, Comparison to L. W. T. Pipes • More wall thickness at the thread (CRR=l.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. • Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. • Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. • Dyna-Thread is safer to weld on. • Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Specifications & Approvals Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). tqca I Flow Control Q allied 16100 S. Lathrop• Harvey, IL 60426 Customer Service: (800) 882-5543 TUBE & CONDUIT 11350 Norcom Rd.• Philadelphia, PA 19154 2525 N. 27th Ave. • Phoenix, AZ. 85009 Fax 708-339-1806 S3-3 ---.. ® TOLco· www,tolco.com a brand otNIBCO' Rev1s1on 5/24/2001 Fig. 98 -Rod Stiffener Size Range -Secures 3/8" thru 7/8" hanger rod Material -Carbon Steel :;:t::;:~I:~~~~ii::o 0 ~::~:I::: ::e:~:::~r::::.mic bracing. i ( • ~1t~~••;: : Order By -Figure number -.... Thread Rod Cut to Length cures 3/8" thru 7/8" rod in Dimensions • Weights nts Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, rod diameter, rod length and finish Fig. 100 -All Thread Rod Full Lengths Size Range -Secures 3/8" thru 7/8" rod in 10' lengths Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 718 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 ({fgpr,., ' . t::;;,;;; Rod Size 3/8 1/2 5/8 3/4 7/8 ■ Main Office/Manufacturing Facility• l'.l7') Sampson twc •Corona.er, 92!!/9 • Ph 909737 5599 • f;ix ~-09 737 0330 Customer Service • 800 786 b2GG www.tolco.com Max. Rec. Load Lbs. For Service Temps 650°F 750°F 610 1130 1810 2710 3770 540 1010 1610 2420 3360 • ®TOLc□· www.tolco.com a brand of NI Be□· Revision 5/24/2001 Fig. 200 -"Trimline" Adjustable Band Hanger Size Range -1/2" thru 8" pipe Material -Carbon Steel, Mil. Galvanized to G90 specifications Function -For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - ( 1 /2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (2 1//' thru 811 Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals -Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature -650°F Finish -Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By -Figure number and pipe size .·; I A J ,/ .-·...-,i ,,,. B A t .· 2: ll2 THHU 8 INCH PIPE }t~f\\ .~~li ,.' '··· -' ./l<d ''",::'.\i, ./ Jr,: • "'\\\t;~~;,.;;:t<; Dimensions • Weights ■ Pipe Rod Size A Max. Rec. Approx. Size Inch Metric B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/s 25/s 400 11 3/4 3/8 8mm or 10mm 31/a 2½ 400 11 1 3/8 8mm or 10mm • 33/s 25/s 400 12 11/,. 3/8 8mm or 10mm 3¾ 27/s 400 13 11/2 3/8 8mm or 10mm 37/8 27/8 400 14 2 3/8 8mm or 10mm 4½ 3 400 15 2½ 3/8 10mm 55/s 41/s 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/s 51;. 600 34 4 3/8 10mm 73/a 5 1000 35 5 1/2 12mm 91/a 61/,. 1250 66 6 1 /2 12mm 101/5 6¼ 1250 73 8 1/2 12mm 131/s 83/,. 1250 136 Main Office/Manuracturing Facility • 13/5 Sampson Ave • Coronil. C/\ 92879 • r11 809. 737 5:i99 • rax 900 73 7 0330 Customer Service• 800 186 o2GG www.tolca.com ~~ . . 8007957 GST10 8020957 SWG 10 8008957 GST20 8068925 GST 20 SS 8010957 GST 30 8009925 GST 25-380 8022925 SWG 25-380 8021957 SWG20 8073925 SWG 20 SS 8139957 SH GST 20 8141957 SH GST 30 8140957 SH GST 20 SS 8142957 SH GST 30 SS ,.I} ,-el~ -, ::J --·· " _ ,~ -~ t '.:,; -.. "' : ~ r~ l· .,, 8038957 DSTR 1 8037957 DSTR 1-1/2 8039957 DSTR 516 8045957 DST 516 8046957 TEK50 8055957 SWDR1 8056957 SWOR 516 8054957. SWOR 1-1/2 8137957 SH DSTR 1 8150922 XP20 8153922 XP 35 8059957 CST 20 8061957 swc 20 X X X X X X X X X X X X X X X X X X X X X X X X CPVC 1-1/2 300 CPVC 1-1/2 300 2-1/2 850 2-1/2 850 4 1500 4 1500 3-1/2 -4,. 1500 2-1/2 -3** 1250 2-1/2 1250 3 1050 4 1500 3 1050 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 2 750 3-1/2 1250 @s LISTED 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0.035 0.035 0.037 0.188 0.250 0.037 0.037 0.037 0.035 0.027 0.043 X X X X X X X X X X X X X X X X X X X * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ~ ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" UL and FM tests were performed in compliance with NFPA-13 Standards. 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1.5 1.5 1.5 1.5 1.5 1.5 0.1050 0.1050 0.1050 0.1875 0.1875 0.0600 0.0600 0.0600 0.1050 0.1050 0.1050 3000 PSI 3000 PSI A /TWBuildex Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. www.itwbuildex.com 800-284-5339 SSS26 ....,..l MECHANICAL TEE • The Shurjoint hole-cut mechanical tee provides a fast and easy mid-point branch outlet without welding. First a hole is cut or drilled at the desired outlet location. The mechanical tee is then positioned so that the built-in locating collar fits within the hole. As the housing bolts are tightened the pressure moulded gasket forms a leak-tight seal. Use of the Shurjoint mechanical tee can eliminate the need for multiple couplings and fittings. Shurjoint offers a full range of mechanical tees: Model 7721: Threaded outlet, NPT or BS21 (ISO-7) pipe threads Model 7722: Cut-grooved outlet (machined) Model 723: Saddle-Let; Small mechanical tee with threaded outlet, NPT or BS21 (ISO-7) pipe threads MECHANICAL CROSS A mechanical cross connection can be made by combining two mechanical tee upper housing segments. While the housing segments must be the same size, the branch outlets can be of the same or differing sizes or configurations. 000 Threaded x Threaded Grooved x Grooved Threaded x Grooved (Model 7721+7721) (Model 7722+7722) (Model 7721+7722) Caution: Piping practices require that main and branch connections are at a true 90" angle. Also be certain that the locating collar is securely positioned inside the outlet hole before tightening the hous- ing. When mechanical tees or mechanical crosses are used as transi- tion pieces between two runs, the tees or crosses shall be assembled prior to making the branch connections . MODEL 723 SADDLE-LET (Small Mechanical Tee) The Model 723 Saddle-Let is the ideal outlet fitting for dir~ct connections to sprinkler heads, drop nipples and or gauges. No need for welding, just cut or drill a hole at the desired outlet loca- tion. Position the Saddle-Let so that the locating collar fits within the hole and secure with the U-bolt and nuts. The Saddle-Let comes with a standard black finish or as an option can be supplied electro zinc plated or painted orange. The Saddle-Let allows full bore_flow and is pressure rated to 300 psi (20 bar). '(~}" ~ . ~.(,}; . .' . . . . . 0 ::.::,.: .::s::J t\; • .. s ~o '\•;:,:.i >, i{•.··'·'· · .3:85 1110 4.37 1110 ;,~, 4.37 111.0 ;;;:;;., ~:, 2:· . 4.37 28 ! ~J.ITTD Tflll\TT®