Loading...
HomeMy WebLinkAbout2013-05-01; Planning Commission; ; CUP 12-13|SUP 12-02 - SDG&E STEEL POLEThe City of Carlsbad Planning Division A REPORT TO THE PLANNING COMMISSION P.C. AGENDA OF: May 1, 2013 ItemNo. 8 Application complete date: Febmaty 25, 2013 Project Planner: Greg Fisher Project Engineer: David Rick SUBJECT: CUP 12-13/SUP 12-02 -SDG&E STEEL POLE -Request for approval of a Conditional Use Pennit and Special Use Pennit to allow the installation, operation, and maintenance of an unmanned Wireless Commlmication Facility consisting of three (3) panel antennas with associated equipment mounted to an existing SDG&E transmission pole and a 240 square foot above ground equipment shelter within the West Bluff N01th Homeowners Association prope1ty. The project site is generally located along the east side of El Camino Real between Poinsettia Lane and Swallow Lane within an SDG&E utility easement and in Local Facilities Management Zone 6. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolutions No. 6965 and 6966 APPROVING CUP 12-13 and SUP 12-02 for a period often (10) years, based on the findings and subject to the conditions contained therein. II. INTRODUCTION This application is a request for a Conditional Use Pennit and Special Use Pennit to allow the installation, operation, and maintenance of an lmmanned Wireless Communication Facility (WCF) consisting of three (3) panel antennas and associated equipment mounted to an existing SDG&E transmission pole and a 240 square foot above grmmd equipment shelter. The project site is located within the West Bluff N01t h Homeowners Association prope1ty and in the Planned Community (PC) Zone. Wireless Commlmication Facilities are permitted in this zone by Conditional Use Pennit. All required fmdings for the Conditional Use Pennit as well as the Special Use Pennit for the El Camino Real Conidor Development Standards can be made for the proposed WCF, and staff recommends approval of the proposed facility. III. PROJECT DESCRIPTION AND BACKGROUND The proposed unmanned WCF, operated by Sprint PCS, is generally located along the east side of El Camino Real between Poinsettia Lane and Swallow Lane within an SDG&E utility easement. The 200 foot wide easement, which contains SDG&E transmission poles and lines, is located within the West Bluff N01th Homeowners Association property, and is bordered by residential development to the n01th, south and east. The three panel antennas are proposed to be affixed to a transmission pole located just n01th of Swallow Lane which serves as the entrance to the West Bluff N01th Condominium development. The equipment shelter is proposed adjacent to the tennis comt near a parking lot which is outside of the SDG&E easement. CUP 12-13/SUP 12-02 – SDG&E STEEL POLE May 1, 2013 PAGE 2 On March 19, 2008, the Planning Commission approved CUP 06-20/SUP 08-01for a similar WCF proposal for the same applicant Sprint PCS at this site. That project was never constructed and is now expired. The WCF proposal consists of three panel antennas and associated equipment mounted to a 125.33 foot tall SDG&E steel transmission pole together with an unmanned above ground equipment shelter. The three panel antennas will be located within three separate sectors. Each sector will consist of one panel antenna. The three panel antennas are a low-profile design approximately 1 foot wide by 6 feet long and will be attached to the existing SDG&E transmission pole by a universal mounting bracket. The antennas will not mount directly to the steel-pole based on the requirements of SDG&E but will hug on the pole and extend outward no more than 20 inches from the face of the pole. Mounted directly below the antennas are remote Radio Heads (RRHs) which are part of Sprint’s wireless system technology. The RRHs are 25 inches long and 11 inches wide and will be attached to the SDG&E pole similar to the antennas. The antennas are mounted to the pole at a minimum height of 40 feet from grade to the bottom of the antennas and a maximum height of 50.2 feet to the top of the antennas. The antennas are mounted at this height range to meet the Radio Frequency (RF) calculations of clearance from solid interference (obstructions) and FCC standards. The panel antennas will be painted to match the existing transmission pole. The radio and power supplies will be located within an above ground equipment shelter. The shelter will contain the support equipment consisting of a self-contained Base Transceiver Station (BTS), equipment cabinets, control power panel, and a GPS antenna. The shelter has been designed to minimize visual and/or potential noise impacts and will be constructed to match the architectural style and materials of the existing residential buildings and will consist of stucco walls with a chain-link security lid. The 7’2” tall, 12 foot by 20 foot (240 square feet) equipment shelter is located approximately 150 feet northwest of the transmission pole near a tennis court and parking lot and 70 feet from the nearest residential building. A flat roof design is proposed to lower the overall building height of the equipment shelter. A combination of existing and proposed landscaping will help screen the equipment shelter to the extent feasible from the common grounds and residences. Any landscaping to be removed or disturbed during the equipment shelter construction will be replaced and irrigated. No permanent backup generator air cooling system is being proposed as part of this project. The WCF operator, Sprint PCS, has been authorized by the Federal Communications Commission (FCC) to construct and operate a wireless network throughout California. Sprint’s PCS operating license from the FCC requires that its market area receive ubiquitous coverage, residential areas not excepting. Currently, Sprint PCS has four WCF sites located within the southeast portion of the City. Although no additional sites are being proposed in this part of the City of Carlsbad, new sites may be necessary in the future to provide additional capacity if warranted by customer demand or if the industry technology changes. The present state of wireless network development involves, to a large degree, the filling of smaller coverage gaps. The primary transportation corridors, commercial areas, and most residential areas have for the most part been covered. What generally remains, are smaller gaps in coverage within residential areas. The proposed WCF site was chosen by the applicant because of its location which will enable Sprint PCS to meet the capacity and coverage needs in this area. Currently, there is limited coverage across the Bressi Ranch development to the north, CUP 12-13/SUP 12-02 – SDG&E STEEL POLE May 1, 2013 PAGE 3 the valley south of Bressi Ranch including the La Costa Greens development, and along El Camino Real. The proposed site located at a high point within the neighborhood, provides the necessary height for unobstructed line-of-site transmission to these communities improving capacity for customers and increasing Sprint PCS coverage in this area. Existing and Future Collocation: Pursuant to City Council Policy Statement No. 64 – Wireless Communication Facilities Policy, whenever feasible and appropriate, WCFs’ design and placement should promote and enable collocation. The applicant evaluated the potential to collocate at other wireless facilities and determined that collocating was not a viable option. All preferred locations within the search ring were evaluated for existing wireless communication facilities that presented a collocation opportunity. However, Sprint PCS’s consultant identified none. There are currently no WCFs located at this site. Each request for a WCF is required to be reviewed on a case-by-case basis taking into account several standards necessary for approval including compliance with City Council Policy Statement No. 64. Any subsequent proposal by another wireless communication carrier to co-locate at this property will undergo the same review process as the proposed project. The proposed project is subject to the following regulations: A. Residential Low Medium (RLM) General Plan Land Use Designation; B. P-C, Planned Community Zone (Chapter 21.38 of the Zoning Ordinance); C. Conditional Use Permit regulations (Chapter 21.42 of the Zoning Ordinance); D. Wireless Communication Facilities Policy (City Council Policy Statement No. 64); E. Special Use Permit – Scenic Preservation Overlay Zone regulations (Chapter 21.40 of the Zoning Ordinance); and F. Growth Management. The recommendation for approval of this project was developed by analyzing the project’s consistency with the applicable regulations and policies. The project’s compliance with each of the above regulations is discussed in detail in the sections below. IV. ANALYSIS A. RLM, Residential Low-Medium General Plan Land Use Designation The project site is designated Residential Low-Medium (RLM) on the City’s General Plan Land Use Map. The proposed WCF project is consistent with the RLM General Plan Land Use designation in that the Residential Low Medium Land Use designation does not preclude the provision of WCF uses, it is located within an existing utility corridor, it is conditionally allowed by the implementing Planned Community Zone, and it will not impact sensitive habitat. The proposed WCF project is also consistent with the RLM General Plan Land Use designation in that the proposed use will serve the residential and business community and region as a whole, including emergency services. Therefore, the proposed WCF use is consistent with the RLM General Plan Land Use designation. CUP 12-13/SUP 12-02 – SDG&E STEEL POLE May 1, 2013 PAGE 4 B. Planned Community (P-C) Zone, Chapter 21.38 of the Carlsbad Municipal Code The proposed WCF is located within an SDG&E transmission utility easement and within the Planned Community Zone. In the P-C Zone, permitted uses and structures are established by a Master Plan. Prior to Master Plan approval, or in the absence of a Master Plan, the property may be used as permitted by Chapter 21.07 for the Exclusive Agriculture Zone (E-A). No master plan exists for this site; therefore, the project must comply with the E-A Zone development standards. Wireless Communication Facilities, such as the proposed project, are allowed in all zones including the Planned Community Zone and E-A Zone with approval of a Conditional Use Permit. The required CUP findings (discussed in Section C below) can be made for the proposed WCF as it is a desirable public convenience and is compatible with its surroundings. The three panel antennas will be mounted to an existing 125.33 foot tall transmission pole at a maximum height of 50.2 feet. The proposed height exceeds the maximum 30 foot height limit permitted by the E-A Zone; however, structures used for other than dwelling purposes and located a minimum of one hundred feet from a property line may exceed the maximum height limit pursuant to Section 21.07.100 of the CMC. The panel antennas will be located approximately 160 feet from the nearest property line. The proposed location and height of the panel antennas at this site are considered acceptable to insure compatibility of the proposed use with the surrounding existing and planned uses. The proposed equipment shelter complies with the height limit and setback requirements of the E-A Zone in that the equipment shelter is 7’2” in height and is setback a minimum of 185 feet from the nearest property line. C. Conditional Use Permit Regulations, Chapter 21.42 of the Carlsbad Municipal Code Conditional uses such as WCF possess unique and special characteristics that make it impractical to include them as permitted uses “by right” in any of the various zoning classifications (i.e. residential, commercial, office, industrial). The authority for the location and operation of these uses is subject to City Council Policy Statement No. 64 – Wireless Communication Facilities Policy (see discussion D below), Planning Commission review, and the issuance of a Conditional Use Permit. Staff has reviewed the proposed project and found that all of the necessary findings can be made to approve the CUP. The required findings and satisfaction of these findings are provided in Table 1 below. CUP 12-13/SUP 12-02 – SDG&E STEEL POLE May 1, 2013 PAGE 5 TABLE 1 - CONDITIONAL USE PERMIT FINDINGS FINDING PROJECT CONSISTENCY That the requested use is necessary or desirable for the development of the community, is essentially in harmony with the various elements and objectives of the general plan, including, if applicable, the certified local coastal program, and is not detrimental to existing uses or to uses specifically permitted in the zone in which the proposed use is to be located. The requested use is necessary and desirable for the development of the community because of the benefit and demand for digital communications and data transmissions for businesses, individuals, public agencies and emergency service systems. The proposed use is consistent with the General Plan in that the Residential Low-Medium Land Use designation does not preclude the provision of WCF uses, nor is it detrimental to existing permitted uses in the vicinity in that the WCF exhibits stealth design and only minor alterations to the existing site are proposed. That the requested use is not detrimental to existing uses or to uses specifically permitted in the zone in which the proposed use is to be located. That the requested use is not detrimental to existing uses or to uses specifically permitted in the zone in which the proposed use is to be located in that visual impacts will be minimal as the equipment shelter has been designed to be architecturally compatible with the surrounding residential buildings within the West Bluff North Condominium project. The 7’2” tall equipment shelter is located approximately 70 feet from the nearest residential building, has been designed with building materials to match the existing residential buildings, and is screened by landscaping to soften its appearance and further reduce its visibility from the residences and general public. The project has also been conditioned to submit an acoustical analysis complying with the City’s Noise Guidelines Manual to ensure that the proposed WCF noise sources comply with City requirements and its compatibility with the existing residences. The panel antennas are not considered detrimental to the existing uses in that the three panel antennas are mounted to an existing 125.33 foot tall steel transmission pole and will be painted to blend in with the existing transmission pole. The panel antennas are a low-profile design that will hug the pole, and extend outward no more than 20 inches from the face of the pole. The collocation of panels on the existing transmission pole also minimizes the visual impacts of the project by eliminating the need to install a new pole structure to achieve the needed height to provide coverage. CUP 12-13/SUP 12-02 – SDG&E STEEL POLE May 1, 2013 PAGE 6 TABLE 1 - CONDITIONAL USE PERMIT FINDINGS CONTINUED FINDING PROJECT CONSISTENCY That the site for the proposed conditional use is adequate in size and shape to accommodate the yards, setbacks, walls, fences, parking, loading facilities, buffer areas, landscaping and other development features prescribed in this code and required by the city planner, planning commission or city council, in order to integrate the use with other uses in the neighborhood. The above ground equipment shelter complies with the E-A Zone development standards, exhibits stealth design, and is screened by landscaping to further reduce its visibility from public view. The location of the panel antennas on the transmission pole will reduce the visual impact of the wireless communication facility by eliminating the need to install a new pole structure to achieve the needed height to provide coverage. The antenna panels will be painted to match and blend in with the existing transmission pole. That the street system serving the proposed use is adequate to properly handle all traffic generated by the proposed use. The use generates very little traffic, requiring only routine monthly maintenance visits and occasional visits in response to operational problems. Swallow Lane will be used to access the site. The existing street system is adequate to property handle any traffic generated by the use. D. City Council Policy Statement No. 64 – Wireless Communication Facilities Pursuant to Carlsbad Municipal Code Section 21.42.140(165)b, a WCF Conditional Use Permit application that does not comply with the preferred location and the stealth design review and approval guidelines of City Council Policy Statement No. 64 shall be conditionally approved or denied by the Planning Commission. The WCF project is proposed in a discouraged residential location as listed in Location Guideline A.2.c. of City Council Policy Statement No. 64. Specifically, a WCF should not locate within a major power transmission tower corridor in/or next to a residential zone or area unless the applicant demonstrates no feasible alternative exists that can accommodate the applicant’s proposed facility. After analyzing eight other potential sites, the applicant has demonstrated that no location in a preferred zone or area as listed in Location Guideline A.1. can accommodate the proposed facility, therefore, staff is recommending support of the proposed WCF at this location (See attachment No.7 - Justification letter). The WCF has been designed using “stealth” design techniques to the extent feasible and is consistent with the Design Guidelines listed in City Council Policy Statement No. 64. The proposed equipment shelter is designed with building materials to match the existing residential buildings, and is screened by landscaping to help soften its appearance and further reduce its visibility from the residences and general public. The three panel antennas are small in scale, mounted closely to the steel-pole reducing an outward noticeable appearance, and will be painted to match the color of the existing transmission pole, thereby minimizing any visual impacts. Locating the WCF on the existing SDG&E transmission pole as opposed to installing new monopoles is also encouraged and consistent with City Council Policy Statement No. 64 Design Guidelines. CUP 12-13/SUP 12-02 – SDG&E STEEL POLE May 1, 2013 PAGE 7 E. S-P (Scenic Preservation) Overlay Zone and El Camino Real Corridor Development Standards Special Use Permits are required whenever a site is located within a Scenic Preservation or Floodplain Overlay Zone. The proposed project is located within the El Camino Real Scenic Corridor Overlay Zone. The El Camino Real Corridor Development Standards were adopted in 1984. The intent of these standards were to maintain and enhance the appearance of the roadway by setting standards for setbacks, signs, building height, grading, and design. The document is also intended to further the goals of the Land Use and Scenic Highways Elements of the General Plan and the objective of preserving unique city resources as they relate to highways. The proposed project is in Area 5 (Sunfresh Rose Company to Olivenhain Road) of the El Camino Real Corridor, which is the longest of the five segments. This portion contains the most diverse land uses and expansive views. The area is dominated by the La Costa Resort development, various residential, commercial, office and visitor serving land uses. The topography offers views of the surrounding hills and valleys. Batiquitos Lagoon is a predominant physical feature along a major portion of the roadway, which the project would not impact. Much of the existing development reflects a Spanish architectural theme. The project complies with the design theme in that the proposed equipment room would maintain the “Old California/Hispanic” architectural theme by using similar building materials as the existing residential buildings. The proposed project is consistent with the development standards and intent of those standards with regard to aesthetic considerations. Each of the requirements and responses to the requirements is addressed in Table 2, below. TABLE 2 – EL CAMINO REAL CORRIDOR STANDARDS COMPLIANCE STANDARD REQUIRED/ALLOWED PROVIDED Design Theme Old California/Hispanic The proposed 7’2” tall equipment building has an open roof design with stucco textured siding, and will be painted to match the existing residential buildings consistent with the design theme. Sidewalks As determined by staff Sidewalks exist along the project site. Signs Free standing monument, not to exceed 7’ above street grade No freestanding monument signs are proposed as part of this project. Max. Building Height 35' from pad grade 7’2” Max. Grading Change No cut or fill exceeding 15' from original There is no proposed grading associated with this project. Min. Setback 40' (assumes above-grade structures) 235’ building setback to proposed equipment building; 245’ setback to existing SDG&E transmission pole. Roof Equipment No roof equipment can be visible from adjacent streets There is no roof top equipment associated with this project. CUP 12-13/SUP 12-02 – SDG&E STEEL POLE May 1, 2013 PAGE 8 F. Growth Management The proposed WCF is located in Local Facilities Management Plan Zone 6. Installation of the facility on the existing site and monthly facility maintenance visits will not result in increased public facilities demands; therefore, the proposal will not exceed performance standards for public facilities. V. ENVIRONMENTAL REVIEW The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15303 (Construction and installation of small new equipment facilities or structures) of the state CEQA Guidelines. Additionally, as Sprint PCS must comply with FCC regulations, radio frequency emissions from the proposed facility are below levels established as acceptable by the FCC, and are therefore not considered a health hazard. In making this determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state CEQA Guidelines do not apply to this project. ATTACHMENTS: 1. Planning Commission Resolution No. 6965 (CUP) 2. Planning Commission Resolution No. 6966 (SUP) 3. Location Map 4. Background Data Sheet 5. Disclosure Statement 6. Reduced Exhibits 7. Justification letter 8. Exhibits “A” – “N” dated May 1, 2013 SITE MAP • N NOT TO SCALE SDG&E Steel Pole CUP 12-13/SUP 12-02 Revised 01/06 BACKGROUND DATA SHEET CASE NO: CUP 12-13/SUP 12-02 CASE NAME: SDG&E STEEL POLE APPLICANT: Sprint PCS REQUEST AND LOCATION: To allow the installation, operation, and maintenance of an unmanned Wireless Communication Facility consisting of three (3) panel antennas mounted to an existing SDG&E transmission pole and a 240 square foot above ground equipment shelter within the West Bluff North Homeowners Association property. The project site is generally located along the east side of El Camino Real between Poinsettia Lane and Swallow Lane within an SDG&E utility easement and in Local Facilities Management Zone 6 LEGAL DESCRIPTION: An undivided 100% interest in and to all that portion of lot 1 of Carlsbad Tract No. 79-28, in the City of Carlsbad, County of San Diego, State of California, as shown on a map thereof No. 10067, filed in the office of the San Diego County Recorder on April 20, 1981, shown and defined as “common area” on the condominium plan recorded March 4, 1982 as instrument/file No. 82-059867, of official records of said County APN: 215-052-13 Acres: 13.30 Proposed No. of Lots/Units: N/A GENERAL PLAN AND ZONING Existing Land Use Designation: RLM Proposed Land Use Designation: N/A Density Allowed: N/A Density Proposed: N/A Existing Zone: Planned Community Proposed Zone: N/A Surrounding Zoning, General Plan and Land Use: Zoning General Plan Current Land Use Site PC RLM SDG&E Transmission Tower Easement & Multi-Family North PC RLM Single Family South RD-M-Q RMH Multi-Family East PC RLM Single Family West RD-M-Q/OS RMH/OS Vacant LOCAL COASTAL PROGRAM Coastal Zone: Yes No PUBLIC FACILITIES School District: Carlsbad Unified Water District: Carlsbad Sewer District: Carlsbad Equivalent Dwelling Units (Sewer Capacity): N/A Revised 01/06 ENVIRONMENTAL IMPACT ASSESSMENT Categorical Exemption 15303 – Existing Facilities (Construction and installation of small new equipment facilities or structures) - of the State CEQA Guidelines ~ <<·.:}\ ~ CITY OF DISCLOSURE STATEMENT P-1(A) Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov CARLSBAD Applicant's statement or disclosure of certain ownership interests on all applications which will require discretionary action on the part of the City Council or any appointed Board, Commission or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print. Note: Person is defined as "Any individual, firm, co-partnership, joint venture, association, social club, fraternal organization, corporation, estate, trust, receiver, syndicate, in this and any other county, city and county, city municipality, district or other political subdivision or any other group or combination acting as a unit." Agents may sign this document; however, the legal name and entity of the applicant and property owner must be provided below. 1. APPLICANT (Not the applicant's agent) Provide the COMPLETE. LEGAL names and addresses of ALL persons having a financial interest in the application. If the applicant includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person Corp/Part.-'=8'-"p'-'-r.!.!.in.!.!t~-------- Title. ___________ _ Title Tenant Address-'----,--------Address 330 Commerce, Suite 200 2. OWNER (Not the owner's agent) P-1(A) Provide the COMPLETE. LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (i.e., partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person __________ _ Title. __________ _ Address. _________ _ Corp/Part West Bluff North Title Board of Directors Address 5651 Palmer Way, Suite A Carlsbad, CA 92008 Page 1 of 2 Revised 07/10 3. III()N~PRO~IT O~GAI!Il;tAT'ION.QB.tltU$1" If' any PE!rson · idenlif~ PU~IJ~rittg {1) or (~) ~pove. is §·nonprofit cir$im@tlon or J2: truet, I!St'(ha rtames :and ~dd(SS~es ofAf'!Y person serving as an offiCer or dlrectO.f of the ilOn· profitor~anization ·Ot·aS trusfl!e or.oaneficiary of the, NorrPr<)flt)Tru.st NA Non Proftt(Trust~ . ..;..· ·.,N .. A __ ...,... _ _......__ TitlE!. TiUe._· ...,...~-_,.------------- A<WI\lSl!. Add~,;.......--------- 4. Haye you had mora th1)ni$500 worth of business transacted with any member of GfW ~ffi: i;ll?ards, Comrnisstoii$, eon:ll'nittaes and for. CounCil within thlj past tWelve ( 12) mortlis? 0 Yes l}d No lfye~; please: indicate person(s}; ..... _ __, _____ ..._....__,_ NOT!!: Attach ad,dii.ionaf sheets·if riecessal)', Kathleen ~iccarilli st9nature ·of<>wner/applfcant's agent if appUeabtetdate TimH@nign Prtnt or type name ofowner/applieallt's agent P·1(A) Page2of2 Revlsed07110 3o "0 ci N 0 "' <Xl (.) X "'" ,.., 0 U1 0 N I w --' 0 "- --' w w ,__ U1 w ~ ~ U1 0 "' <Xl (.) X "'" ,.., 0 U1 E g N r:..: STRUCTURE /1: Z718327 TIE-LINE #: 23011/1:3605 R/W /1: 31560 APN SBE #: /1: 215-052-13 SIGNATURE DATE SDG&ELEGEND ,.., "f• ~ VI C INITY MAP THOMAS GUIDE PAGE: 11 27 SECTION: ES O!BfCDQNS fBQN SfRJNT IRVINE QEFJCF· DEPART CO~~ERCE lOWAAO EL Oloii~O RE'AL. TURN RIGHT ONTO El CAWINO Rf/L, TURN LEFT ONTO EL CAMINO REAL, TURN RIGHT ONTO BR'I'AN AVENUE, TURN RIGHT ONTO CULVER DRIIIE, TAKE RAWP RIGHT FOR 1-S SOUTH TOWARD SAN DIECO. AT EXOST 44, TAKE RAWP RIGHT ~0 FOLLOW SIGNS FOR LA COSTA AvelUE-TURN LEFT ONTO LA COSTA AVENUE, TURN LEFT ONTO EL Olo!INO REALjCRS1 1 NORTH, TURN RIGHT ONTO SWAI.lDW LANE, ARRIVE AT SITE WITH SIDG.I:E STEEL POLE ,r.T RIGHT. DRIVIN G DIRECTI O N S GENERAL PLAN LAND USE: RLM ZONING DESIGNATION: PC ZONING APPLICATION: CUP 12-13/ SUP 12-02 rint· SDG&E STEEL POLE #Z718327 SD34XC861D 1926 SWALLOW LANE CARLSBAD, CALIFORNIA 92009 • INSTAI...l.AllON OF SPRINT TELECOWWUNICAllON FACILlY WITH OUTDOOR EQUIPWENT CABINETS ON CONCRETE PAD WITHIN A (P) 12'-0" x 20' -0" CONCRETE BLDCK ENCLOSURE; • INSTAULATION OF (3) SPRINT P~EL ,I.NTENN,r.S 0 1 PER SECTOR WOUNTED TO AN (E) SOG&E STEEL POLE; INSTAULATION OF (3) REMOTE RADIO UNITS (RRU) WOUNTEO BELDW P4NEL ANT<NN...S TO AN (E) SDG&E STEEL POLE; • TELCO lr: ELECTRICAL SERVICE TO SITE~ LANDSCAPE & IRRIGATION WOOIFICATION PROJECT DESCRI PTI O N APPLI CANT /LESSEE SPRINT 310 COMMERCE. SUITE 250 IRVINE, CA. 92602 CONTACT: ~ !<AGEL PHONE: - PROPERTY IN FORMATION owNER, CONTACT' PHONE: AREA OF CONSTRUCTION' OCCUP,r.NCY TYPE: CONSTRUCTION TYPE: CURRENT ZONING: A-P.N.: WEST BWFF CONOOWINIUM ...SSOCATK:>N & SDC&E CARLSBAD, CA 92009 LESUE HOUOAY (760) eoJ-9496 x115 240 SQ. FT. u V-B NORTH: PC, EAST: R-D-W-0 WEST' L-C, SOUTH: R-D-W-0 215-052-13 ~DICAP REQUIREMENTS: F...CIUTY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAP .OCCESS NOT REQUIRED. L.E1iAL DESCRIPTION: SEE SITE SURVEY ON LS-1 JURISDICTION' CARLSBAD COORDINATlES: 33' 06' 31.51" 11T 16' 05.01" N40 63 P ROJE C T S U M M A R Y ALL WORK AND WATER~LS SHAUL BE PERFORMED AND INSTALLED IN .OCCOROANCE WITH THE CURRENT EDmONS OF THE FOULOWING CODES AS ADOPTED En' THE LDCAL GO'o'ERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERWIT WORK NOT CONFORioiiNG TO THESE CODES. 1. CALIFORNIA ADMINISTRATIVE CODE (INCL. TITLES 24 lc 25) 2010 2. CAUFORN~ BUILDING CODES 2010 3. CAUFORN~ EUECIRICAL CODES 2010 4. CAUFORNIA MECHANICAL CODES 2010 5. CAUFORNIA PWMBING CODES 2010 6. ANSI I EIA-222 E&F 7. Loc;.L BUILDING CODES 6. CnY 1 cou~ ORDINANCES ~-CAUFORN~ FIRE CODE 2010 EDITION C O DE COMPLIANCE ARCHITECT: WSA ARCHITECTURE & PLANNING 3194 AIRPORT LDOP DRIVE, SUITE C-1 COSTA ~Es.\ CAUFORN~ 92&26 CONT.OCT: MICHAEL J. SHEWBRIDGE PHONE: 9~.251.1177 LEASING and PLANNING: DEPRATTI INCORPORATlED 139ola CAWE BUENO CANAR JAMUl. CA 91935 CONTACT: TIM HENION PHONE: (503) 519-65'il1 SURVEYOR: CALVAOA 106 BUSINESS CENTER ~VE CORON4, CA 92860 CONTACT' ARMANDO DUPONT PHONE: (951) 280-9740 UTILITY LIAISON: DRVCI P.O. BOX 974 DOLORES, CO 81323 CONTACT' JOHN J HERNANDEZ PHONE: (970) 882-3575 SDG&E' CONTACT: SO GatE 6335 CENTURY PARK COURT, CP-110 SAN DIEGO, CA 92123-1569 CONTACT: FRED CLARK, LAND ~AN,r.GER (CONTRACTOR) PHONE: (619) 550-6105 P ROJE C T T E AM SHEET DESCRIPllON T1 TTTL£ SHEET T2 PHOTOSIW DIHIBifS LS1 TOPOGRAPHIC SURVEY A1 SITE PLAN A2 ENLARGED SITE PLAN A3 EQUIPWENT & ANT1ENN4 LAYOUT A4 ELEVATIONS A5 ELEVATIONS A6 DETAILS A7 LANDSCAPE PLAN L1 IRRIGATION PLAN L2 PLANTING PLAN L3 IRRIGATION DETAILS L4 PLANTING DETAILS S H EET INDEX I ISSUED FOZONI NG ACCESSIBILITY EXEMPTION F.OCIUTY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS NOT REQUIRED, I~ .OCCOR~CE WITH CAUFORN~ STATlE ADMINISTRATIVE CODE. PART 2, TTTL£ 24, SECTION 1 1 03.1.1, EXCEPTION 1. DO NOT SCALE DRA WIN GS RE.V. 3 3 3 3 3 3 3 3 3 3 3 3 3 3 CONTRACTOR SHALL VERIFY ALL PLANS 4ND DIISTING DlloiENSIONS AND CCNDmONS ON THE JOB SITE ,r.No SHALL IW~EDIATlELY NOTIFY THE CML ENGINEERS IN WRmNG OF f.Nf DISCREP4NCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. GEN ERAL CONTR A C T OR N O T ES ~ ~~==================================================================================================================================================~ Sprint· 16200 \ION i<,r.Rw,r.N ,r.VENUE, SUITE 100 IRVINE, CAUFORNIA 92612 -:pROJECT INFORMATION: SLJ.54XCt161LJ SDG&E STEEL POLE #Z718327 1926 SWALLOW LANE CARLSBAD, CALIFORNIA 92009 SAN DIEGO COUNTY -=CURRENT ISSUE DATE: ~ 01-24-13 ~"'"" '"z 0 N IN G II ~ REV DATE DESCRIPTION _, .. -.--.---BY :- 3 01-24-13 PLANNING RU CO~~ENTS 2 05-02-12 SDG&E REDLINES ARC 1 03-29-12 100" ZONING ARC 0 03-14-12 90% ZDs FOR ARC REVIEW "::PLANS PREPARED BY: MSA Architecture .& PJanning J194 Airport Loop Drive, Suite Cl Costa Mesa, California 92ij26 ph 949.251.1177 fax Uol9.2ijl 1120 Sir* Ani . Son Diego . San Francisco www.mso-ap. CfXT1 -=CONSULTANT: )epratti )5 --OEPRATTl INCORPOR4T1ED 13948 CAWE BUENO GA- JAMUL. CA 91935 -=DRAWN BY: CHK.: APV.:= TITLE SHEET NU~BER· REVISION: T1 3 SD34XC861D Sp r i n t ® Fr> 18 2 0 0 VO N KA RMA N AV E N U E , SUIT E 10 0 IR VIN E , CALI F O R N I A 92 6 1 2 PRO JECT INFO R M A T I O N : SD 3 4XC 8 6 1 D SD G & E ST E E L POL E #Z 7 1 8 3 2 7 • > D I .... . ·o ~ ti ' I ~ ·~ i I'l l .. .. ., 1.1 . . ~ jl i: f .e l ~ .! ! "' I .! ! - ': ! ';: : , J r:: ~~~ a ~{a I 1 > ~ 6 '§ II . .~ "'- 1 ~ '"" " ' ~ .... . I'l l .~ -r:: ~~a ~~ J!3~ ~J~l ! :: J · i· -E " ' Q, d " 1 ":' r~I!J i 0 E 2 ~ 1 .J~ ~-~, ~ it J t g ! 0 u ~ ~~a 1~1 il~ s ~ ~sl w i ;: QJ "0 ~ ci . ~ N = -- 0 • "' II . <D "' ro - QJ j A I u -QJ X ~ 1 ... ... :.. . . , ~ ,.,. , = ~ ; ~ 0 ~ ~ c:::: : l (j ) 0 ... . . "'C B l 'i: ) N = QJ ~ I "' 0 s .. ~ = 0 ' ~~~ ~ w a. -' a. 0 0 ... H~ ~~ o._ ... Q. -' ... . r·· · ~ w JU U t w - f- en (j ) ~ 1 ·, ,· w 19 2 6 SW A L L O W LA N E CA R L S B A D , CA L I F O R N I A 92 0 0 9 SA N DIE G O CO U N T Y -.. .. " - . r~ ~~;~ ~ ~ ~ 13 11 IS S U E D FOR: t ----~~ ~ ~ - _ j - r;: c . v .: - Uf \ I c.: - - - UC . ; ) \ . . . . . ( " " ; 1 1 " " ' II V I'I : - - - D T ;- 3 01 -2 4 - 1 3 PL A N N I N G RU CO M M E N T S 2 05 - 0 2 - 1 2 SD G & E RE D L I N ES AR C 1 03 - 2 9 - 1 2 10 0 % ZO N I N G AR C 0 03 - 1 4 - 1 2 90 % ZD s FO R AR C RE V I E W PL A N S PR E P A R E D BY : .; ; <.:> 0 (j ) I MS A 0 ;;; ro u A r ch i t e c t u r e & P l a n n i n g 31 9 4 Air p or t Lo op Drive , Su i t e C1 Co s t a Me s a , Ca l i for n i a 92 6 2 6 X ... ,.,. , 0 (f ) , ' - c - ·- · - · -··-- - = - - ---""' - - ""'- '"""' _,_ ,~ - c~ ll = .... I =· !! ~ = •J Cl:l l ::; - I ~ ~ ·· 1 = ll. - -= IE 1 -= i j = h A I Cl:l l 11/l = ~ I'J~ i ~ .s it N '! ; i - i E ~ .. . 1 Cl:l l ~ u ;; ,r. l +" " j u § ~f s::: : '1 : = > - E I ·;: : t g = = u • 0. . - :: = c;; ... "" .!1 - ' .:: 1 -~ L - - - ph 94 9 . 2 5 1 . 1 1 7 7 fa x 94 9 . 2 5 1 . 1 1 2 0 San 1 a A n a . Sa n Die g o . Sa n Fra n c i s c o ww w . m s a - a p . c o m CON S U L T A N T : )e p r a t t i ~~ DE P R A T T I IN C O R P O R A T E D 139 4 8 CA L L E BU E N O GA N A R JAM U L , CA 91 9 3 5 DR A W N BY : CH K . : AP V . : El I II II PHOTOSIM EX HIBI T S 0 0 N " Il l II ~SH E E T NU M B E R : RE V I S I O N : ,.,. , 0 N T2 3 N N :0 ::: ; I SD 3 4 X C 8 6 1 0 Overall Site Detail SEC. 23 T 12 S, R 4 W, SBB&M --\S:®----=.--NBB:JIJ'IB"W~-;-11" -~~--""""";,j7=~~..::;..,.~-- Title Report Rli&WEII'f FlBm .WIIM. 1lllE llMWI' .......... fii1If1/fTIIIlmMIY.£t.lllll Legal Description Ill CIIIUP ICIII'II1EIIm'll 1111 Ill Ml. .H!TfltllTI(IIfTIJIT I IFCIIIit!IIIIIJIIII&r& iiP-.11 II liE UTriFQUM!, r:tl.lm' IISMI!mq Jlllll£11~ AS-atA -1llfl!ll'"IJII.II&7; 1'1£511 IN!"fl1lZIIJICSIIfii!IZiautrfiBBB11 lltM!Iil.llllll!;_,.,llllfE1liEDAS._AID"IItJ£~1f.III.I!WIEI'11ft11(114 IB!AS~ E. 8HiliiBI, IIIJ'i'DII. IEDIIlS II .51111 a.um.' li!BIM 1IEIIRIQIEAIBiilmi AS !lDIEA!BBfiS II£ IETRifll/11 JlflmAIIID IF aiiEIIIllim aiiiiiJIS' 1111 .11!311K'IDII5' JEUID11ft11(11 ( IIBI' AS IJifiUEitr FIE /IJ. lfHJl1IIID IF l7i'DII. .IBDiDS fT $1111 Qlll7t Mf) JIIY QUI IE1EJF1DIIBBB11-.x1S li&RJ. ar:B'T_,_MJ.JIIRIIIB_,.,IIIIIEJIElJAfiiB-IJfifiBI,IIIaltft,;AS-tlfSMJ~ ... NSODIIB'T H1mDt MI.~ !1, lOKI:~ OHR/f'llliOCNi/DI !!iii/STNiaS AMJNJ.IIIE1/QiQII} IIIIZii'll rll IIIlER rll fR1I JilT tiC lfiiiJUaiJ RIO/I SU)tm 'ftQI/JIIBU A f1INE PMIUfl Ill All! !lllll fEU IBIW llE l'fi!Btr !lR'IiE fJF SUI IN RI/1/E PIR'05E fT 1/E E:ftaatlit:ll& lllfZ4I'IBit ~ EJfii/ICBIM Nil rMIIr OF SUI MIIE!Wll.l. ali ~ fJifR II'IIJII(JCNfJf !!iii/STNiaS Nlllllllli' RIO/I S4P lDTBf lENlS IF lin El£ IIE1IIt1tS 011 QJER E!MV1ff RKM 5lliFAa LtrAllliiSrM-flliEIIHIIIMINIJ a/L!IW;~fT 11£ Mlii£IZ5DI&Jilllt ff/IEIICIIIZRS1fla} IMITII£-fi'IUJI~!I,QIS~fli/DII'IIIIIlCAIIIJSIIISTAII:D"NIJIII!BI:ASSCI'IIEIIl1FAIIllf;5HML HAl£ NO fliGHT 108f1ERIIVI11E Sllf"A~(JF Nfff'afllfJN 1IE1IlU A6tll£ S4ll FWEPii/AIJll. 10NIJ SIIIJIEETfEJ.OIIIf£ ffiE!iBn 5Wil!r fJF 1/E S411lOTRRJNTPfll'fi!E lfii151Ela Tower Profile NOT TO SCALE CARLSBAD I I I~ I I I~ '---.. '---.. I~ I I I I ',J ® \\\ Assessor•s Parcel No.: ....,.., Lease area A llfll"IFI.MIII.MIIlS ... !MIITfltllTI(IIfFIJITIIFCIIIitllllll JIMCI'"C }t-at•lll£arrtTOIIUIIIII. aDmfiSIIflmq llillrfT~ AS-atA-1IIfl!ll'"IJII.IID7,; IUS II IM!f111ZfTIM!SIIIf lEI! UJII" .I!WiiEI' at Mil !II lilt ,_ IIIIIEJIElJ AS "'ZZIQ M!'A"IIt J£ ~ 1f.lll IEIXREDIINIQI ( /J6I AS ~/IJ. ~IF aRK IBDIIS IF 511.1 CI:Um: ~ATJ£.11Ui'111£ASUJ.YaRIB'fTlDT~ IIOI:l"a:tl'lr'( .lll.l6'1fEf IIOI:l"JIIm'" 1111:15 FEB IIIII£ ,_111' lmiJM" ra:£ Slnmn; 1fJilJ Flfi 1/fia SII725V'I Ul FEB Ill A /Ofr lmiW1IIfEHIIIEIIIIIAS/Ofr'll~ ra:raw.-.5!1ZVW IIIJIJifEf IIOI:l"-~111"1 U:111fmlil A /OfriE1BW1llll/lJEII/liJ IIJAS /Ofr 'r, --~ ~ T.SIIfll) 110'ZIIJI2Bft; J.ll flEriiiAIVIT'IDIIW1BIIIlHIIIl1JIIIASIVIT'~ ---~&.!JIEETIIIWC/UITfT - UllllUIIIlU -ATIVIT' "A" ASIE!Di&IIAIIII£ IJ07 .llinll'lut fJ/11/fR l'fliEr ~ J/111/fR IJ07 Jll"l!2:JI't a58 Flfi rflU" .s;n1)1"( &II FEB 10 BE Bill fJF Sill JIB'. II1J01.l(llll /EtaM AT,., 'IY AS /IESII1IIIED liD£ rflU" .5!IZVW 1.5D Flfi rflU" ...,_llnl .a• 1m; 1/fia .511'111Zit .lUi' lfR l'fliEr Slllzr:Jii't 111111" lfR 1IO'Z oCnii'H't lOUD fEET 10 IN!" 811 II 5111 5Jiill'. ll/lllUIII/E..> /EtaM AT,., "r' AS IE!Di&llliDE IOir .wr.J11l1"1 Z.ll Fm; liiOI:£ ~ 11.• Fm; B6ll" Ezr:Jol'l SIUJ lfEf liiOI:£ .sr.tnn' ~11 FEB 10 IN!" 811 fJF Sill) Sill'. FIIISH SUIFACE ~-..... ""~,..,.. """ ..... "" """"""""'"' """"""""" ""' "" ~""' """'""' """"'"" '"""' """"'""' --- :::;; ~ QJ Sl :>::' "" 0::: (Jj ~ f.-,,, ~ c...i bj .z -~ ~ ~ l.,_J ' Site Detail "< St:AL£ 1"=20' I "IlliG !I m~i..,., il + 214.81"' --X Easements X----". ... __..--I ...... ,,. ... ':m.mtG EXISTING TOWER· BEE PROFILE GEOGRAPHIC COORDINATES LAT.= 3.YOB'.:~i1.51" LONG.-117,6'05.01" (NAD 83) --- '2!12.J7 'ZIII.DI& •211l74M& .. ,. .. ®:::rmffiii'IUliiiBIIIIID.flfrN.Nf'!mi.I!WIEI'fEIIIJN/TtC III!IIJDIIlllll.llll£~ fTIIlm {lt01JBl ®:,:::s"{R;::,t:flt) liB IIIIIODITM. Nf'!ml.tm'li!ID IZIDID 4 1!111: llfiUEitr.lll. S111, IJDIIl Jf7, lltm:JII. <.V ~ .-:J cu tw£ us 1111 laBfTII. ~UF~m~IEUIIER ME 11 ,. ltffiiiEifr., uarrc IF tm:W .I!B2'JiJIS ®===-~ EIIMI:EI7"11111DBfrN. .IUFIIU .I!WIEI'.UWZ: ... lfiiiEIIT.III. .wm (JF @ :::rm FfiiiiiERQI(DI) IDIIIIS Nf'!m~IIBDIED Mlllllr Ill IBt IS1IIIDr .Ill. IIIIi IF aRK IRI2II!i: (RimED ®:, = Ffll fWJI£ Ill Ff'BIE! .IUFIIU -MB. IQ ,. ltSJIIIEifT M2 .tl-ll.ml (JF tm:JII. .I!B2'JiJIS tiU! @:=':ffJ."'::=jl':t:a. rar:rr~t:/::IJ~ :lilT~ NWJ a.M:IIJIJIIVRIZ ®:..::.~~':':==-=(JF:a~~-=1111 @)~.-: ~IFBIEIIIIFBIE.IUFIIU .tm'li!ID .11.r4 lilt ISJIIIDr.lll. 81-trlla IF aRK JBtZ ®::=:;':~~~~~':==~~~ MRii'ISIIIIt:B Ffllllfl' NIJ Ml. 1VR1Z CDIUDD IUIIIEli tllfiHill MI!Aii' -IIIJ Nf1IRTliiiiDS l'lliRI!R .tm'li!ID.II.r/11 Ill afiiiiEIIrMI.81-lZJ1112!; IJDIIlSI(JFaRJII. IIDIIIS (ltJTPUmiiH-Ml. JIEAIDLIII:IEIEJI JIE UfBU 5IEliiE:li -.M 3IIZIID" MI. tE lMI!llfR .-.c5lE AT fiQir AIIUI at fiiQI UfBU 511" fT fiiQIIIIJ EID'T FArvrr IIJTMJl1l .,. .w1 fflt7flln'J ®::::::::=c~::==-==~.::v:~:..:~~-Ffiii'T'f LS' 1111 «J (1£ IIMF FEB lit E/01 lll" IF BE MDIE1Ir IF JIE IDIIU IIJTMJBIIE/EJIIB) ®:::s"·=rGDI5RCID".IUFIIU 1m1m1 _,IT. DllllfiUEitr.lll. JIII1-IDIIt&ll llll'i'DII. @:::;j'"ffii:MR.IUFIIU IEQaiJ MJMff IT, J111t lmiUBIT.w.l ~II aRK mDII! {11/JnBJ ®:,:::s"~~ SlllCT IIIJIVUWRr.IUFIIU .tm'li!ID Mlllllrtl..!llllfiiiEIIT.III. ~IF aRK YICINJ'I'Y MAP· N.T.S. GRAPmC SCALE 20 10 20 FEET Geographic Coordinates as Shown tMIIlU) IAllllfl" IJ'OI'JI.!fl' u.tll£tr7'11'05.111' (IWroJ IAR&" IJ',.'JI.:Il" tl~mf~Etr7'"11'tll.tll' Date of Survey .U..T IT, IIDI Basis of Bearings liE OUIJiJII QUi!INIIf mD' (JF-(111111 uJ, OUIJJMliiE .. Bench Mark ICSII'SIDUE/frMI Willi 'IIM-QDINSW, ElEllllllfll: 1fii.IFEB/llllllllfl,} UNETADI..E ~ .. lliiiEC"nOPI '~~ " sss:u'o7"E moo• " S20"l!5'5J"'I' 7.711' u SII'J"l!5'5J"'I' 10.24' " NtJB":J4'o~lf 711.411' " N611"34'o~lf 7.51' " tmJ"25'iD"C ~41' " tmJ"25'!5TC .... " SS9:U'o7T Q.66' " S20"253.J"'I' 11.!10' "' N611"34'o~lf "'"' "' NtJB":J4'o~lf ,_,. Sprint. SprintPCS • 4683 CHABOT DRIVE, SUIT 100 PLEASANTON, CA. 94522 PROJECT INFORMATION: SDG&ETOWER SD34XC661 D 1926 SWN....Lr:JN LANE, CARLSBAD CA 92009 SAN DIEGO COUNTY, CA 06520 0 07/21/06 PREU~INARY JV 2 3 07/25/06 ADD TOPO OB/10/06 09/10/12 TITLE REPORT- FINAL LEASE AREA PLANS PREPARED BY: MSA An:hitectlue Ill .f'iaMing, Inc. 3191:1 Airpart Imp Drive, Suite a CaD Mesa, CA 111626 Ph. 9fJ.252.1171 "'"'""""' --CONSULTANT: 411 JEW.IICRCLE.SUITE205, IX:RlNA. CA. trlllllll loS MN GBM pjl!!l-iiKHIIIIIO F:B!II-BII'40 TQJ.: lm(:N.VAIIf< --JOB NO. CADII5:ill DRAWN BY: u JV LICENSURE: ~ TOPOGRAPHIC sHEET """"~"u RVEY REVISION LS1 SHEEr 1 OF 1 SHEErS SDJ4XC861 0 SITE PLAN I I "~ o' 25' so· 100' 1 Sprint· 11200 liON I<ARWAN A\IENUE. SUITE 100 IR'iiNE, CAUFCRHIA 1121112 ~PROJECT INFOR'-IATION: S l~.d.Y~ SDG&E STEEL POLE #Z718.327 1926 SWALLOW LANE CARLSBAD. CAUFORNIA 92009 SAN DIEGO COUNlY URRENT ISSUE DATE: 3 01-24-13 PLANNING CO !AMENTS RU 2 05-02-12 SDG&E REDUNES ARC 1 03-29-12 100:1C ZONING ARC 0 03-14-12 go::r;R~DsEWFOR ARC PLANS PREPARED BY: MSA An:hitecnue • P1ltimniD8 3194 Al111ort Loap Drive, SUite C1 Cool.a MeiiCI, Colil'vmia 92828 ph 849.251.1177 fu IMUti\1120 IIIIWIAIII • 81r1 Diego • 8s1 F~encilco --·C6m ONSULTANT: )epratti ) ___.) CHI<.:=APV.:~ I uJs I uJS! SITE PLAN I HEET NUMBER: REVISION A1 1~,1 NOTE: PROPOSED GRADING SHAY. BE 3 CUBIC YARDS AT EQUIPMENT AREA. Sprint· SDG&E STEEL POLE #Z718.327 1926 SWALLOW LANE CARLSBAD. CAUFORNIA 92009 SAN DIEGO COUNlY [ URRENT ISSUE DATE: 01-24-13 II ~.__Issu-ED _FOR._zo_N_I N_G __ ] ,, .. :--:--.. -REV =DATE DESCRIPllON BY· 3 01-24-13 PLANNING RU CO !AMENTS 2 05-02-12 SOO&E REDUNES ARC 1 03-29-12 100:1C ZONING ARC 0 03-14-12 90::ro ZDs FOR ARC REVIEW ~PLANS PREPARED BY: MSA An:hitecnue • P1ltimniD8 3194 Al111ort Loap Drive, SUite C1 Cool.a Meoo, Colil'vmia 92828 ph 849.251.1177 fu IMUti\1120 !tid Alii . S~r~Diego . 8s1 Frencilco --·C6m ~ONSULTANT: )epratti ) ___.) DEPMm INCORPORI'IlED 138411 CALli: BUENO c;ANAR .wiUL, CA 91935 !::DRAWN BY: CHI<.: APV.:= ENLARGED SITE PLAN REVISION A2 (P) SPRINT TELCO CONDUIT UNDERGROUND, FOR CONT1NUA110N SEE SHEET A EQUIPMENT LA YOlJT ~----:-~'-------(P) COAX CABLE SUPPORT (P) "VAL!AONT-!AICROFLECT" TRI- BRI\CKET WITH ANTENNA t.IOUNflNG PIPE (1 PER SECTOR, J SECTORS) (P) SPRINT RRU EQUIPLIENT MOUNTED BELOW PANEL ANTENNA ( 1 PER SECTOR, J SECTORS) SEE DETAIL 3/AS SECTOR'C' AZIMUTII.ZSOO ,.,. (E) SDG&E 125'-4" HIGH STEEL POLE fZ-718327 ANTENNA LAYOUT FRAME CONDUIT STUB-UPS i.E) PARKING? AREA ~--(P) SPRINT COAX CABLE UNDERGROUND ROUTE FROM EOUIPMENT CABINETS TO ANTENNAS ON POLE (FOR CONTINUI\TION SEE SHEET 1\-2) '------(P) SPRINT LANDSCAPE SHRUBSffi I SBCfOR'A' AZIMUTII 200 ~ ~---(1~) SPRINT PANEL ANTENNA ANTENNA PER SECTOR, J SECTORS) SEE DETAIL 2/Afl .... SECI'OR'B' AZIMUIH 9QD ....._----EXISTII~G POLE FON. BELOW 1 I 2 4' Sprint· 11200 liON I<ARWAN A\IENUE, SUITE 100 IR'iiNE, CALJFCRHIA 1121112 ~PROJECT INFOR'-IATION: Sl :ri4XI :B61 D SDG&E STEEL POLE #Z718.327 1926 SWALLOW LANE CARLSBAD. CAUFORNIA 92009 SAN DIEGO COUNlY URRENT ISSUE DATE: [ 01-24-13 ~SSUED """ZONING II ] REV =DATE DESCRIPllON B'( ,, --:--:--:- J 01-24-13 PLANNING RU CO !AMENTS 2 05-02-12 SDG&E REDUNES ARC 1 03-29-12 100:1C ZONING ARC 0 03-14-12 90::ro ZDs FOR ARC REVIEW ~PLANS PREPARED BY: MSA An:hitecnue • P1ltimniD8 3194 Al111ort Loap Drive, SUite C1 Cool.a MelfCI, Colil'vmia 92828 ph 849.251.1177 fu IMUti\1120 !tid Alii . S~r~Diego . 8lrl Frencilco --·C6m ;::<:oNSULTANT: )epratti ) ___.) DEPMm INCORPORI'IlED 138411 CALli: BUEHD c;ANAR .wiUL, CA 91935 !::::ORI\WN BY: CHI<.: APII.:= EQUIPMENT & ANTENNA LAYOUT REVISION A3 (E) SDG&E 125'-4" HIGH STEEL POLE #Z-718327-------1 (E) TREES-------, (P) SPRINT EQUIPMENT CABINETS WOUNTED ON------. CONCRETE PAD Will-liN A (P) 7'-2" HIGH CONCRETE BLOCK ENCLOSURE WITH STUCCOED EKTERIOR FINISH & PAINT COLOR TO WATCH EXISTING RESIDENTlAL BLDGS. (E) """''u";:r---, SOUTH ELEVAllON (E) SDC&E POLE CUMBING PEGS ~----(E) SDG&E 125'-4" HIGH STEEL POLE #Z-718327 TOP OF (E) SDG&E POLE ELEV. 125'-4" _,----(E) SDG&E POLE CLIMBING PEGS (TYP.) --=~ r.;;::=-.:-----(E) SDG&E UTI LilY POLE ARMS &: ELECTRICAL CABLES (TYP.) EL.£V. 70' -2" ....._----(P) SPRINT PANEL ANTENNAS Will-I RRHa MOUNTED ON (E) SOG&E POLE 1------+-li--------(E) BUILDING (BE10ND) SPRII'IT EQUIPMENT CABINETS MOUNTED ON CONCREfE PAD WITHIN A (P) 7'-2" HIGH CONCRETE BLOCK ENCLOSURE Will-I STUCCOED EKTERIOR ANISH &: PAINT COLOR TO MATCH EXISTING RESIDEN11Al. BLOCS. + (E) SDG&E UTILI1Y POLE ARWS &: ELECTRICAL CABLES (m>.) ELEV. 70' -2" SPRINT PANEL ANTENNAS Will-I RRHs lolOUNTED ON (E) SDG&E POLE .. FIN. GRADE 1------(E) BUILDING (BE10ND) I 1 30' (P) SPRINT EQUIPMENT CABINETS MOUNTED ON ~' CONCRETE PAD Will-liN A (P) 7'-2" HIGH CONCRETE BLOCK ENCLOSURE WITH STUCCOED EKTERIOR ANISH & PAINT COLOR TO MATCH EXISTING RESIDENTIAl.. BLOCS. (P) BTS CABINET ON '(/)OWN-UN< rn RAISED CONCRETE PAD . . ~-f'·9;1 I il I I I · ... · .. : .: · .... ·/ I I I I I · ·· .. :. ·.·/I I I II I I I :· [ ·.· :-; ... fl I I I I I ......... ·.· . .''f I I I I I I . · ·.· :. },; I I I I I · :··. ···v1 1 I l I I I .'J ,· ... ~··.AI I I I I I ·.~ .. i I I I I II I I L__ (P) TRANSFORMER ON CONC. PAD I I I I I I I I I ' I I '"" I I I / I / I I " I --1 I I I l_j I I I ~P) SPRINT 4' WIDE STEE L DOOR WITH SIGNAGE, PAINT TO MATCH WALL SOUTH ELEVAllON-EQUIPMENT ENCLOSURE 1"-WEST ELEVAllON 0'2' 6' 14' I 2 30' Sprint· 11200 liON I<ARWAN A\IENUE. SUITE 100 IR'iiNE, CALJFCRHIA 1121112 ~PROJECT INFOR'-IATION: Sl :ri4X: :B61 D SDG&E STEEL POLE #Z718.327 1926 SWALLOW LANE CARLSBAD. CAUFORNIA 92009 SAN DIEGO COUN1Y URREI'IT ISSUE DATE: [ 01-24-13 II ISSUED FOR: l~TE=:, __ J ,, .. :--:--:- 3 01-24-13 PLANNING RU CO !AMENTS 2 05-02-12 SDC&E REDUNES ARC 1 03-29-12 100:1C ZONING ARC 0 OJ-14-12 90::ro ZDs FOR ARC REVIEW ~PLANS PREPARED BY: MSA An:hitecnue • P1ltimniD8 3194 Al111ort Loap Drive, SUite C1 Cool.a MeiiCI, Colil'vmia 92828 ph 849.251.1177 fu IMUti\1120 !tid Alii . S~r~Diego . 8s1 Frencilco --·C6m ;::<:oNSULTANT: )epratti ) ___.) DEPMm INCORPORI'IlED 138411 CALli: BUENO c;ANAR .wiUL, CA 91935 !::DRAWN BY: CHI<.: APII.:= ELEVATIONS HEET NUMBER: REVISION A4 + TOP OF (E) SDG&E POLE EL.EV. 1251-4° NORTH ELEVAllON (E) SDG&E 125'-4" HIGH STEEL POLE #Z-718327--------,. + mP OF (E) SDG&E POLE EL.EV. 125'-4" (P) SPRINT PA.NEL 1\NTENNI\S RRH11 MOUNTED ON (E) SDGII:E POLE EAST ELEVATION (E) SDG&E 125'-4" HIGH STEEL POLE #Z-718327---- (P) SPRINT PANEL ANTENNAS WITH RRHs MOUPfTED ON (E) SDG&E POLE SDG&E POLE CUMBING (lYP.) (P) TRANSFORt.IER ON CONC. PAD . I···:· t : . . ·.. .. : .... : .l···· .J.· ·. 1-----(E) BUILDING TERRAIN PROFILE 1"- 0'2.' 6' 14' I :50' 2 EAST ELEVAllON-EQUIPMENT .----·(P) SPRINT EQUIPMENT CABINETS MOUNTED ON : ... · .. PAD WITHIN 1\ (P) 7' -2" HIGH CONCRETE BLOCK ENCLOSURE WITH snJCCOED ElCTERIOR FINISH II: PAINT COLOR TO MATCH EXIsnNG RESIDENTIAL BLOGS. OF (P) LANDSCI\PE SHRUBS AT FOREGROUND I'Q 0'2' 6' 14' I 1 Jll' (P) SPRINT EQUIPMENT CABINETS MOUNTED ON CONCRETE PAD WITHIN A (P) 7'-2" HIGH CONCRETE BLOCK ENCLOSURE WITH STUCCOED ElCTERIOR FINISH II: PAINT COLOR TO MA.TCH EXIsnNG RESIDENTIAL BLOCS. (P) CHAIN-UNK LID (P) BTS CABINET ON RAISED CONCRETE PAD · .. 1 . . · .. . . ... . ·. ·· .. ". : · ... : , . ... ··. .. FIN. GRADE I'Q 0'2' 6' 14' C... I ;... I 3 Jll' Sprint· 11200 liON I<ARWAN A\IENUE. SUITE 100 IR'iiNE, CALJFCRHIA 1121112 ~PROJECT INFORt.IA.TION: s 1~4)( ;861 D SDG&E STEEL POLE #Z718.327 1926 SWALLOW LANE CARLSBAD. CAUFORNIA 92009 SAN DIEGO COUNlY URRENT ISSUE 01\TE: [ 01-24-13 II ISSUED FOR: l~TE=:.--J rl .. :--:--r:- 3 01-24-13 PLANNING RU CO !AMENTS 2 05-02-12 SDG&E REDUNES ARC 1 03-29-12 100:1C ZONING ARC 0 03-14-12 90::ro ZDs FOR ARC REVIEW ~PLANS PREPARED BY: MSA An:hitecnue • P1ltimniD8 3194 Al111ort Loap Drive, SUite C1 Cool.a MeiiCI, Colil'vmia 92828 ph 849.251.1177 lu IMUti\1120 !tid Alii . S~r~Diego . 8so Frenciolco --·C6m ;::<:oNSULTANT: )epratti ) ___.) DEPMm INCORPORI'IlED 138411 CALli: BUEHD c;ANAR .wiUL, CA 91935 !:::DRAWN BY: CHI<.: APII.:= ELEVATIONS HEET NUMBER: REVISION AS (P) SPRINT 7'-2" HIGH ClotU WALL LANDSCAPE PLAN (P) SPRINT TRANSFORMER ..,OUNTED ON CONCRETE PAD ---J NOTE: HOMEOWNER'S ASSOCIATION LANDSCAPE COMPANY "WESTERN GARDENS" SHALL MAINTAIN THE NEW PLANTED AREAS AROUND THE SPRINT "'-....,.ENCLOSURE. "'-....,. '-<'0:) PARKING7 AR"-4 Sprint· 11200 liON I<ARWAN A\IENUE. SUITE 100 IR'iiNE, CALJFCRHIA 1121112 ~PROJECT INFOR'-IATION: Sl :ri4XI :B61 D SDG&E STEEL POLE #Z718.327 1926 SWALLOW LANE CARLSBAD. CAUFORNIA 92009 SAN DIEGO COUNlY URRENT ISSUE DATE: [ 01-24-13 II ~-ISSU-ED -FOR:_ZO_N_IN_G __ ] REV =DATE DESCRIPllON BY ,, .. :--:--:- 3 01-24-13 PLANNING RU CO !AMENTS 2 05-02-12 SDG&E REDUNES ARC 1 03-29-12 100:1C ZONING ARC 0 03-14-12 90::ro ZDs FOR ARC REVIEW ~PLANS PREPARED BY: MSA An:hitecnue • P1ltimniD8 3194 Al111ort Loap Drive, SUite C1 Cool.a MelfCI, Colil'vmia 92828 ph 849.251.1177 fu IMUti\1120 ltldAIII . S~r~Diego . 8lrl F~encilco --·C6m ;::<:oNSULTANT: )epratti ) ___.) DEPMm INCORPORI'IlED 138411 CALli: BUEHD c;ANAR .wiUL, CA 91935 !::DRAWN BY: CHI<.: APII.:= LANDSCAPE PLAN REVISION A7 Alcatel Lucent 1'.-.uhort I YUUM 117 KKII (6SMII/ 1 l'rod u •I llc•cription. '!his Remote R~dio ll~ad {RRIJ) support~ the 1900Mii1 spc:clrum with J Qut•d 'I ran,mil ami Quud ll.o•c:ivoor cunf•gnmlitm .<uppnt'lln~ 4x4 ~W nl nutpUifll>WCr in ~ dw1l hc~d cnnfiguration • -~"1'1""'' up In I> ~.tnic·" ul {'IJ\1A in ttll' 1900Mill SP"'" 11111 mod;, ·,ardwarc rca.;ly for ~x<ll. I J· ~11MC! (Jualtrcl>m>l<>f' yl ~uppllrl~ up In ~ ~arric·" ul l 'I lMA (~inglc tcclmt>ll'g)') .~Upj)<lll' ,\J~(i ~ RV l H' mo•; ht· pu\H:rec.l lrnm A l• .. :m~·l-~ llf<"IU ~..·nhi ~\cl 5L•ppuJl> ll}l•oi/lc>. ft\m 'l'"""J c~blc humllc Tcchnknl.~p<"<"ilirllfiun.: 25" x I I, I"~ 11.4" i>O nur•d~ 4•45W (I MUW I nlnl) l'l~O-J~SMH:<T., I 18>0 • 1915 Rx Antenna Inlet r~"" : () cratht ' Tct.!!Pcr~lurc Range: 680W • . 65MIV :tOdil 7116 I)[~ rctllulc -40C to , sse S<u:>.P."!'b_AI~~ l .l_l --------....!...- PROPOSED RRH REMOTE RADIO SPECIFICATION Produ<t 0111 Shut APXV9ERR18-C MMMftffi:@h£ • \fa(••l=a. •l.,'h1f.t1 ddwntUt-pffl ... tdM .,.11!•nud p .. Hislo" 111 ron trailing lnht-rMII lnl•,(•~nt•. Tht tilt 11: h1f...W .-dju'llt.ll.blt' ~ 10 cfll<ge • tllyh tUpptlPtdtln otf 111 uppfl-ld .. obfl 0\opkllllly • II Ulll •lndl!pl!r!Ckn~ tont10l ol II!!IK\rkill downtll• +o, toO Bnd '"' b•ndt •low pronle fa1 aow llo'bUDI llll;piCt •Q1.1kW •nJiolto"f10-.ifu•l • tllgh -rvf!t~·hiKk rotf~ • AISG •ou\patllll• lllffiOl•U~ oll\lillll.;ibl• •lldU Jtdfl• ·AJO 10 lbe•nothlllllu~ttbltl tJV9 o,,-,can'nk11Rr791 181 (6(l ~.;.) 1501 ughl GrL.'! AA1703S 3 0 K.J_g~ Alltrrun.~l'ft y,d ~lvilfliZ'f"d ~!~lil'4 PROPOSED PANEL ANTENNA SPECIRCAllON 2 CHAIN-LINK UD DETAILS NOTE: . N I ·,... GENERAL COJIITRACTOR TO CONSTRUCT CHAIN-UNK ENCLDSURE WITH THE FOLLOWING (AS REQUIRED) 1. 1 1/4" X 3/4" TENSION BAR El<TENSIO N EYE UJO P 2. 1/B" X 3/4" 0 1 2" O.C. STRETCHER BANDS r----(2)-'lto"tt HIL11-KWIK BOLTS KB-3 0 g"o.C. (6" MIN. EMB) ICBO ESR-1385 L-----J"e STD PIPE (GALV) HORIZONTAL CHAIN-LINK FENCE SUPPORT "------1/4" THK. STL. COLLAR DIAioiETER AS REQ'O. FOR 3"• HORIZONTAL CHAIN-UNK FENCE SUPPORT '--------PL 3/8"x6x12" UJNG CD~· --------------- TOP OF' Cr.IU WALL 3/8" PLATE WITH 2-5/8"tl REDHEADS ~A BOLT SLEEVE ANCHORS T-COLLAR 0 BLOCK WAI.l. CONN ECllON 2 1/2"11 HORIZONTAL SUPPORT GD----------------- T-COUAR U CHAIN-LINK FENCE POST 2 1/2"f HORIZONTAL SUPPORT VERTICAL CHAJN-UNK FENCE POSTS-WHERE OCCURS GD~-------------- TOP OF C~U WALL 3/8" PLATE WITH 2-5/8"11 RffiHEADS DYNA BOLT SL£EVE ANCHORS-,~----~~------, 8)~-------------- 1 1/4' MAX. MESH CHAIN-UNK FENCE WITH TIE 3/16" WELD--IH. AU. AROUND 2 1/2"f HORIZONTAL SUPPORT 3/B" PLATE WITH 2-5/B"f REDHEADS DYNA BOLT SL£EVE ANCHORS TOP OF Cl.l U WAI.l. 0 T-COLLAR 0 BLOCK WALL CONNECTION @D---------------- 1 Sprint· 111200 VON KARt.! AN AVENUE, SUITE 100 IRVIN E. CALIFORNIA !i2&1 2 ~PROJECT INFORMATION: SD34XC861D SDG&E STEEL POLE #Z718327 1926 SWALLOW LANE CARLSBAD, CAUFORNIA 92009 SAN DIEGO COUNTY '::cURRENT ISSUE DATE: ~ 01-24-13 II ISSUED FOR: ,, .. -: ~ .:-- J 01-24-13 PLANNING RU COt.1MENTS 2 05-02-12 SDG&E REDUNES ARC ., 03-29-12 1 OOX ZONING ARC 0 03-14-12 9~ ZDs FOR ARC REVIEW ~PLANS PREPARED BY: MSA ~~p~ 3194 Al'1'orl Loop Dr ..... Suite C1 Coota M-. Calrtumla 92G25 ph 94g,2s1.1177 fix 114Uit112C lllnliAnl . Son Oioga . Son F...,.;..., .... mstl-tlp..C6'tt ~CONSULTANT: ) I epratti ~ IJEPRATn ~CO-lED 1 .Noll! CAI.ll BLDO GNWI .-J1.. CA 91131; .._DRAWN BY: CHK.: APV.:= DETAILS EVISION: A6 3 SOl-4-XCB61D EQUIPMENT LE15END FEBGO 1-t:lt:El. 11~ ~ PREfi&RE 1YPE B.At::«l"!LH PREVENtER-12• ABOVE ttlette5T OUTl..Er, leE WEN ~N ONl. Y IF EKI511N5 5'1'511:M t-W; NOt£ OR IS ~. \,III!ICDT-11~6A~ VALVI!! ~l'ti!E410m Hl.c:::&lS 1"5BR J-h'E flmAI~ tllt.Ha;E) ""' 1-eif-1 OR. 6R54.1CRJ Hl.«::&a -.;co PRffQI.RE RE.sl.ILATDR ~INE612E}. 11\ST~ ""1. Y IF ExJST1U& 9TAT1C. ~ 15 6REA.1Bit 1K<\H. /!10 P.5.1, RAIN PI~ E!IP&-c.f>~E$~ C.OMnle:J~ v'~Vl' -lt&r~ IN.~~~ ~19J,.S IN RS::.T~ VAL.'Ve BOX A.TRIBttT ~TOttARD5C.Af'E. AAit.eiRP E::5P-5Mr c.otJ'TROI..l.. {4 STATION) lr.J GVTPOGR I..O<:..IC.IHS H.t\LL H::ll.tlr BOX IN!fi'ALL 1~0£[) 'HEA'Jl.I:R. flrATlON" ON FAfGIA. ~OR.~ eo)C,o"J==t~TAL, 561t!iOR ro AAVl5 Cl.5AR 'VIEH'QF &ICY ~ H'.TER PIPE GJ... ~1!1 ti-(1\I"LINE :t• NC 1-.AASStl PVC.. f'iG,TER, Pft sc.H. 40 ~Nllf>e 1-112• AKJ :5H'ri1..LER) t'Vc. ~TeR. P'IPI!' cJ.. 'oo "4"-Hr.t• a.~'\~ P.'(.. 9R,IQI.fev'E ac,J-1. 40 -.2• MIN. aR2X: DIA. oF PIP£ cR HIRE BJWJ::;11...E.. IN!!n"~ ~ A1.L STF!!EET Clfit DRIVE CR05c51NISS SPRINKLER HEADS ,. p L~ • 0 '~IE$$~ 51J£1BJ.El:t $PR~ RAnt BIRD 111806~~ b* POP-U" !*RAY .SO Roar H-\TfRINS !W!.T£1-1 AAIN BIRD Rt'CS-1404 ~ Sf"T. IMit.VHR 6 ID "" NOTES FOR MODIFYIN15 EXISTIN15 SYSTEMS THIS ~TIS A NC:oiFICATICt>J QF ANrxi511N5 S'I"5'J&.I, M ~TOR. IS ~B.l.E FoR f'lae ~lf'I(..ATIOW OF ~ IEXISOTIN& SIT£ (.D\biTIGNS AN::! !GIJIA-elr R£1,.AT£cl TO 11-IIS fl'r'S1'B-f. 'fl.llfl V!RIFIGMIOU fMALL INCA..1t)e. EIJr IS NDf LD-t111:D TO: 1lfE ElOS'Tlt.ra PRE!!!1SliOE AND R..OH AVAILABI..E,. THE M'Ait.LIHE fii<!E AND L.DC.ATIOlt 1l4E E;OSTBC.£, l..DC.ATION AND RJNC..llON OF VH..Vf5. M<\STER VH..Ye. ~NO C.~ GoONTRA!.TOR SH<I\LL ht::IT1JP\o' THE o.A.Cl (~~~ZB::I R:f~TATIVEl n-t-E::IIA~'I"Gfl' Nh' Pl$c:.Rl!PNt:.ll!$ ANPIOR ~lc.T$ ~ 11-¥ 1"'11!:1 .. 0 Vl!RII"'ICATION. AND 1'1-tE PRAHl»&$. r¥t..T!R NVSoT eE FAJ;NIDEJ TO All F1.1aHT Mlt..TERJALP\Rir.& AID AJ=1ER. c.c:2>&TRJ.t.TIQN. M 111-tiHS AND AI-CWT c:l' HATeR. APF\.18::1 ~ 1-fAINTAJN 11-£ 'V156ETATIGN IIJ. A+EAl.nn", Dl66'die RE!!ii'MAllf" (i(:N)ITICN 11-E C.ON1'RI\C. TOR.~ cJJr, <:,MJ AWD GR. DIVERT IRRJeAT10N. Uel 9RiaR. TO SITE D&iOL.mON. OR EXCAVATION IN ORDER TO PRE!!iERVE HA.~N9 n:> l1fE R&fAIH!Ne £liTE ARV6 CURINIS AWD AFTER C.OleoTRU:..nON... fl.£ CC)H'fRA(.TOR.~ AOJ)WB-11-EAJ» TO MA.TCI-I 1HE EX~11WQ 9'YS1B-f NV At\.IJM( RELOGAlE EX~TM ~1~-~Q..ER HEADS TO ~lEllE AWR:I5fD IH5TAllAnOHHD IHSIJRE I~ CDVf!R.A6E FOR TtiE EX1'5>nt6 NO l8:H PJ...ANTIHB5. HB1. HEADS MA.Y eE ADaED IH. 1l1E FOllG1111N5 Y+\.YS, e ~~~~,aj_1l~RAL~~~~~~~~w:e~~~~~ 1H! H!AD$ TAAT AAV'E! ea!N ~. ® ~=~'"=~~~c,~~~~=~lJJ-:ir~~TO fl.£ !£H. V'~VE{!). ~ ,-90%1BLE IF 1"48£ ~ A.V'A.II-ABLE .-tA.11~ ON 1HE ExJ§11UQ ~OR ADDI110HA.L STATICN HOOI.l..ES GAN eE ADCIB). @ ~o~g=~~=trr~~~c.o~~~~=~AN&t !IF'Rit.«l..ER. t1EAD5. "O bk2t rxrffP ne H!.x]HIH M' 1 <?bPl ffR H!Hrn= •N fl():§noo eee c..w FROYna= 'B QH VEl ex ITY "'*""I I uqr ee MEAJI'K ItWJ 5 EfFI Ff'1'1 C£(GQl ne cay'tRA.( roe <§H61 1 YfF!Ft" If ne EX]fn'INA tWfO'F'H l.fiFS 6 HA"trfR YAI 'If -All)' t«H \{AI Yf5 Hlfff BE (LM!FCJ'EQ fW' HIRE TQ 111' HAfii'ER YH \IF 6NQ C.C'MF!J I fR n£ GGlNTFAljfOR SHALL CJJr, CH" AND OR DIVBU IRRI6A.TIOK LiteS f"'RROR ro SI1E O&tOI...IllON ~EXCAVATION IN ORDER TO PfelfRVE 11A~N5 TO lltE R&fAININB S41E AReAs c:\RIN6 AND~ c.cnt5~TioW. n£ c..GINTFAC..TOR SHAll ADD HB1. t£1rr05 TO MATGH n£ EI<ISTIH6 !I>YSTEH NO ADJJST/ R:!lO<:..ATE EKISTIHS SPRI~ tfEAI:;e TO AUG:f.MODA.1E THE~ lt.&TAll.ATioN NO INSURI:! IQQ,. ~FOR. l1t!! !fXISTitG lroNPm-t f'L,J\lJTitJeo$, t..t:!H~ ~l" Be'~ IN 1HE FoU-DHNS HA'I'9. L ro '""' '"''7 •• PO.C (P) SPRitfT 8' HIGH CMU WALL (P) SPRitfT TRANSFORMER ~OUNTED ON CONCRETE PAD IF~ ARE t.l> AVAJL..Aei..E STATIONS ON 'THE e;<JSTIW5 COH.11W~ INSTAU. NEri ~H!R~ANP cETAIL.!ll VEA.IF"'"'f'l~l..a::,.ATicN ... 11<,...... GRASS AAFA7 ~ ~------------------------------------------------------------------------------------------------------------------------------------------------------------------------------~ CONCRETE CURB (P) SPRitfT 4' WIDE CONCRETE PATHWAY' ----.. / ......._ / " I \ I ~~~~~~ \ I ~·GAL~bO'HIBH ~ \ ~ I \ I \ / " / ......._ / --.. -- ~.~IA~R~GA~~=O=N=P=LA==N==============================================================================~~~==========1~ Sprint~ 18200 VON KARMAN AVENUE. SUITE 100 IRVINE, CALIFORNIA 92612 ~PROJECT INFORMATION: ~10 SDG&E STEEL POLE #Z718327 1926 SWAI.1DW LAHE CMLSBfD, CAUFORN~ 92009 SAN DIEGO COUNTY LCURRENT ISSUE DATE: ~ 01-23-13 II niSSUED FOR: UREV -DATE ~~~~I:ION __ J ,-I .. -: ---: ---:- J 01-23-IJ COMWENTS RU 2 05-02-12 SDG.tE REllJNES ARC 1 03-29-12 10011 ZONING ARC 0 03-14-12 so. ma RlR ARC REVIEW ~PLANS PREPARED BY: MSA Arc:bltet:tun~~ cl: PlazuJJzw 3194 Airport Loop Orr.,.., Suite Cl Coota Mesa, California 92626 ph 949.251.1177 ta IMU5LIIIO .... . 611ft Diego . San FranciiCD www.msa-CTJ.Com ~CONSULTANT: )epratti ")___.) --t3141 IWJI! IU!NO -.wM. Cllle1tJO LC -------~~DRAWN BY:---CHK.:--APV.:El ~ ARC I MJS I MJS I LICENSURE: ~'""' "''-'' ~ IRRIGATION PIAN SHEET NUMBER: REVISION: I L1 1~,1 n£ GGlNTFAljTOR SHALL CJJr, CH" AND OR DIVBU IRRI6A.TIOK LiteS f"'RROR ro SI1E O&tOI...IllON ~EXCAVATION IN ORDER 'R) PfelfRVE 11A~N5 TO lltE R&fAININB S41E AReAs c:\.RIN6 AND~ c.cnt5~TioW. n£ c..GINTFAC..TOR SHALL ADD KB1. t£1rr05 TO MATGH n£ EI<ISTIK6 !I>YSTEH NO ADJJST/ R:!lO<:..ATE EKIS>TIHS SPRI~ tfEAI:;e TO AUG:f.MODA.lC THE~ 11-&TAll.ATioN NO INSURI:! IQQ,. ~FOR. l1t!! !fXISTitG lroNPm-t I"',J\lJTitJeo$, t..t:!H~ ~l" Be'~ IN 1HE FoU-DHNS HA'I'9. L ro '""' '"''7 (P) SPRitfl" 8' HICH CMU WALL (P) SPRINT TRANSFORMER ~OUNTED ON CONCRETE PAD P L A N T 6HRUID6 N 6 LE6END tef'~WtJ&eaa~ TO'(OIJ ~.---CIII~.,.,.._.., -lt-C111-~-I'I..A'I!I .-. ... __ , " .wLI .. CONCRETE CURB (P) SPRitfl" 4' WIDE CONCRETE PATHWAY' ---... / ......._ / " I \ I ~~~~~~ \ I ~·GAL~bO'HIBH ~ \ ~ I \ I \ / " / ......._ / ----- Sprint~ SDG&E STEEL POLE #Z718327 1926 SWAI..I.DW LAHE c:Ml.SBf.D, CAUFORN~ 92009 SAN DIEGO C0Ut4T'I' nCURRENT ISSUE DATE: u 01-23-13 ISSUED FOR: J 01-23-IJ COMWENTS RU 2 05-02-12 SDG.tE REll.JNES ARC OJ-29-12 10011 ZONING ARC 0 OJ-14-12 so. ma FCR REVIEW PLANS PREPARED BY: MSA Arc:bltet:tun~~ c1: P.buuJJzw 3194 A1rport Loop Drl.,.., Suite C1 Costa Mesa, California 92626 ph 949.2.51.1177 ta IMU5LIIIO IIMaMI • 611ft Diego • San FranciiCD www.msa-CTJ.Com CONSULTANT: )epratti ")___.) II ~~DRAWN BY:=CHK.:=APV.:[] ~ ARC I MJS I MJS I LICENSURE: ~'"m 0~NG PLAN SHEET NUMBER: REVISION: I 1~,1 I L2 (f) ~ •• ICIIZI.E• 2.~5ttull~ ~ ..... ~tJFMLCH 4.flf.FF&Mr ~ f'W.~-.oEL&. ._. 1/iiMCM .....u! ,...-lrun' '=~:g~~~ ==~NMIII.5m5 ... PWo~-.oliECitii.L ~. ~ J.A'IIJW. fW'R RISER YiiTH SPRAY OR BUBBLER ~) POP-UP SFAAY 1 .... :!11-d'H.L<II 2. ftOPLUI' 1JIIIIllltAY W'llllll«<.lRt '· 1"\A:: sell ..., 1!1.1. 4. MN11LEX ft1'.:E'T al- ~:~l~=~:= _......!lUI' •• I"\A::SCII...,11!1!<>RILL ,._~I-A~ PI~ e. ~,:O..:A.~A,-.~ +tGaiZDHTitL f5G:E ftR filiiRIMQ.J:R IIU!I' - li"'IO!!MU''I!V-- .2.~t<Ha-AOI'II ~ ~CP~~ttletetf 4.. CGPPBlllllON It fJF 2} , CoOPP'I!Itl'l"'! tm'IC:.OU ...... 91- 1. C'oCOPI"Bl..,.!U.ftOFIIII --~""-"~.~!- I. rtefALL ~ f'RM!Nn!R NJ ...,lAID ltf u:::acAL. c;,oces NO +IPALnt ~. 'tiJIPf ~ lllllf'GI.I!~ fi'IIIIIOtll TO IM!n'""-"'nCIM. PRESSURE VACUUM BREAKER I. ,...__.L-~CF _c;oo.., 2. wrt.'I'Bl PIIII2:IF lZ\ItiOIK.Timt DDF,_, U. I'TAtJI 4, V~'il! BOX ~'nt~ ~IMC:It!NI!! "'P--OP- O.~~VAL.'Wt 1.1'..:.-.0I<ll'ftJ!- .. 1'..:.-~1!1.1. "·=:'N~ IO.IIIOICI:ft C1'41 "·~~IU.LIIOOml, 12."""' I"AIPLftrl! Pft 15.~tclt4QTII!oRI!LL 14. ~ 1iCiH 4fQ MAL.~! APWR!R II, ~ IJ\TIItAL Plf'e 1 ... ~==~~ C.ONTINIJED VIII.~Al.& IJPOH.GOMFl.EllON 1ltE ~l"ClR: SHAlL Slll'f"LY 1ltE ~ Villlt AGOt-f'l.ETE SET OF ~let..E "A5-B.IILT" DRANNaS. neE A5-B.IILTS 5H4J..L ~ lliE LOCAT!Ot6 OF All f'CIINT5 OF c.oHHEC.TioH, VALV'E$, c.R051:511ol56, GUIVK ~ ND 0'1'l'ER. NAit.l.lttE ~Dit-ENSIQt.lfDA(;(.I.RA'JB..'I"f"'i<<M n-t:>~~611Eae..e::;.TS.I'IJ ADPrT10H. Tle~TOR '5ti"lL 5LPP1.Y TriO r2J ~~rs ~llefi&Gti VALVE'S ~ ~c.OL.OR.c..oDB7 TOlliE~IN5C.~ STATION. T+£ GONTRAC.TOR M.IST A1..!JO f\RWISH 1110 1'!1) !ETS EAGH OF 1ME FOLL..DH~ Am' 9FEI::.IAL.. VAL YE OR SPRit.Kl.ER AOJIF.on.fB.lr 'WOI..5, ICE'I"S> Fa<! n£ GOH1l'!.Dl.L.BO: ~ QJICAC c.aiPI...CR IC:E'r'5 AND AN'r' OP!AATioH NAWI&l.S ~ M E&JIPl-t:tlr IH5TAl..l.m. ... _ TtiE GONTRAGTOR'S ~ 5ttA1..L ee FlU'181.Lo=\AAMI'EI:D ¥GRONE fl) fULL YEAR FROM TltE DATE OF ,4£,.c.eF'TA»::.C BY' THE Ot"f.eR. AM' CJEFe::..nVE MATERJA1..5 OR POOR ru:lR:K~IP 5H6d.LBE ~CJ OR~T1:PAT No OOS.T TOM 0~ ... ._ A GliALIFIEO fiJPRV!fJOR SHAU. BE ~IBI..E FOR OPERA.1lt.t81HE l~t!ATlONS S'Y'S'IB.f5. AD.JJ5TIN8 Tt£ CONTRDLl.Bi!S NO ~VU·~ T+E ff'f'B::iTI'v"B£55 OF llE IRRIBATIOlJ 5'1'5TEM. UtARr ALLC.ON'1"RRO...L.f f'f<:OI5RAMS, ftEC.GifWIN5 DA.TE, TIH: ,l..EN6tfrOF 1'¥1'11:RIN6 FOR EAC-H 5TATI~. Rf5ET G~ AT LEAST MOH.THLY TO AGGG\IH.T FGR: ~ V~AT10NS. lf>U£C.T AID AD.J.IS.T lHE BITIRE lt006AnoH. 51'5TEM rt:e::Lt' c:uR.IltS ~ll 1lfRI,I O:::.ToefR At..t:l61"i'S~Y ~ llfl5 ~TOF llfl5 ~C.~ FQR L$N:S,H:'T 6.1:2 ~5PO'JT>,.U$ A 1-t)lg,rlJRE fi!NSINS> oe/ICE 1'0 EVALW..1E ACtu~ SOIL MO>IS1LRE. OB!IER:v'f t.t)ZZI.S FOR PROP!R PATTERN AWE> PRE!&'ii.A:E. Q ISOLATION VALVE I. ~ ltGCJCIWCJUn:JIOrtM J;'A'-~~ ~ ~~~!a+410Coe»e~Un' IIO.~Tl<lN- .. -,., 111140'11! C)OMIWOI. VAI.W!I I. I•IMGH ~ !lGf-1 40 GCICUI' ,.,_ ........ &. -SII'I'I.THID_,.-.J! !J. I!Wl. V"'-'llt!. ,_ I.IMIN> ..... ,..,....._'" __ '·~~TI.N!DI!P11I &.SCIIIIOI"\A::~MD T.QJ!.INIPPI.!S i. IRCK~41R!!Q.PIRIIOX 1).. SU+ IJQ PVc# Uri!QM 4. SCIIIIOI'Io'C.III'I'U!il "'·~~ II, s,t4•~3r.&BIG~. IRRI~ATION SPEC. S. •• ~ UID"'"1GNi 1le GQtll'R,A!C.TOR ~ FIEii.P Y!RIF'I" 1le exi&T1Ne I"\4.TER ~ (P5JJ ~ AVAIL.AS1.£ Fl..DJ'i (8.P.HJ f:RJOR TO GOleTRir.TIOlt NOT1Pf T+E c:JWl.I:R.'5 AIJTlfClRIZED ~AT1V: CO.ARJ 11-H:DIATS...'( GF AH'r" D15CRB"AN:.IE; Elf1l'S:1{ M AL.lUAL f'P'J!~ AND P\.OH AYAI~ HI'$ T~ Sf-Ott.~ IN 1H!:5f! ~Neo$. 'Jlflflo DE!&IBN IS DIASRN+fA.TIG. ALL PIP~. VALVES. ETG,. SHOHt HITlfiN PAVED AREA5 15 FOR DE518N Gl..ARilY ONl. Y NO 5HAU. Sf lt6TAU.ED IN PI..AllTIH8 A.REir6 l1ttBlE F'0551et..E. 00 NOT J11Ll..fU..LY IHSoTAl..L lHE 5F'RJHJo::l..BO:.s.Y51&1 AS>StfGWtal THE CJRAI'ONI!>S rM:fJ IT 1'5 <:eYIOL'S> M 1'1-t: fll'fi.J;I11fi\T ~ ARI!! LIWKHCmH c:eGnwt;.T1CHS. ~ Pl~t:$ OR. t>l~fii'IJ n£ AREA!! £112E ANI:) L•.-'l"arr ma..1 L'ERE t.t)1 VON!5II:)fREI:) 11.111-E ORIQINAL DealeN. ~llPf n-E O . .._.R OF '!iiX:M GISS;'TA.JCT10Nfl AND Olf"'f"B<ENGet lt-M:DIA'JB..Y . ll.lllE E\l&lT llfAT llE t.oTIFIGA.T10Hfl REGIJIRED Bf 'TWf'!iE t.t)'lEfl ARe NOT PfRFGIRMED, lME IRRieA.T10H. GONTAAGTOR SHo=\LL olr65tJt.£ RE5PGINSIB1LrTY FOR AWY REVISION~. ll~IT'f"~NG~t~ llE GOWTAAGTOR 5J1.fri1..L M.IIJNTAIN. A Ql.lr.LIFifO !tJFIERVISOR. FAMILIAR.HITH 1ltE TYPE OF rORIC NO 1l1E C.~T ~ON SllE AT ALL llMES D~IH6 IH5TAU.AnOH. OF n£ J"'RJC.NOFRIM.o.R'I" M.o..IH.~. ALL Soi'Rit.A.ER Bit.IIPMEN.T 1.101 OJ'tEiitNI5E DETAIL.EP GR 5of'B::.IFIEU SKo\LL flE lr.6TJrrd..LECJ f'!ER TliEMo\HLf'AC.ll.fii:fR'S ~T10t6. It!.~~ IN!n'H&A'I'ION l1E 1-WNLit£ PIFE SMALL BE lliSTAU.ED At(£) Rt::VTED n:> AVOID I.Nf'GlRfEEI,I oe&T.aa..ES fl1El..D.H6RADE. ~ LDGAnON5 TAI<E F'FC:IORITY ~ IRRJ6A.T10H. f'IPIN5.5TA«E TREE LOCAT!Ot6 f"R:IOR TO 'T'Fil!EHc.HitU7. lliE AIJTOMA.T1C. c..oN1'ROI..1.E AI'O n£ BACK:Fl.Ot't DEV'IC.C SttAI..L ElE FJr£.TORY ASeEMBI..ED NO IN!i>T.AI..LED F!:R M-\HLFA!.TURERS ~T10t6. RNA!. L..tX.ATIOlJ OF "1l1E AIJTOMA.T.:O ~AID n£ BAC.Kfl.Gt't DEVICE~ BE ~ B'l" 1ltE OAR.. PRIOR TO ll5TAU.ATIOlJ. 1lE 120 VOLT s..e::.~c.AL GOHHEC.TioH FOR: lHE GOHT'R.O~ ~ eE F"\RNISotiED B'l" ~. 1M! c.oN'AU<.~ SAAik co'*P~te ne ~Of' 116!! aa::r'ttlc.'-1.. !eRVt..e ro 11E APPRo.IB:I CDhiTROU-Bit l.DCAT10N 11111-111-E ~ C.ONTRA(. ~ 11-E flfR'IIc.E TO 1lE GOlJTt:IOI..LfR. .J.hGllON BOX SMAlL BE lliSTAU.ED BY A Llc.&S:D EL.EC..TRIGI.,._lJ, llE IRRI6A.T10H.GON'T"RAGTOR SHo=\LL M4IICE n£ FIHAL c.,ot.t.e::,TIOHS TOn£ AII'T'r1M4onG ~R5 f"'RRIM' lHE PIIWVIDEP J..W:.TION BOX. ALL 111RE:SRWM 1ltE CON.TRDll~ TOn£ ""''R:lM'ATIGVALVE:S~SEGOA"'!R.Die::..T B..RIAL. MINIMI.t-1 •14 ~INSTALL 1H. TME SAl-E TPEll:ott A5 n£ HAINLINE )'f-ERE P0551B1.E. c..ot-fMON l'iiRE TO ee 111'111E 1H. c.OL.OR.. c.oMT'1i!lCll.. l'iiRE'S TO SEA C:llf"f'Bi!ENT c.oL.OR ~ EACH ~A. Uf£t>. BUIQ..E AND l'APE HIRE& A 1-tiWt-IU.f OF 1'BIJ (lQ) FEE1 ON CENT£'Q_ ntE GOWTRAC.TOR 5J1.fri1..L R.LN lMREE (3) ~ARe ... IRE5 NO 0t£ fU GOl-ft-tON I"'IRE FROt-1 n£ c..oM1l<'Lll..lR. TO E..l£..tt S(D OF TltE Mol\llJ LIHE FOR. FVTl.l<:f 1.15E. EK11:ND 1l1E J"'IRES AA ~ TBI. /lei FeET, WJ::E A COIL N.b !q.,A(.E IN A RfC. TAo~ ~ BoX. I-ABE~ T1E I.IO 'i!H1• ALL M'AIHLft£ f"IPIN5 AID c..GIN'1'RIOI.. Nl~ ~ PAVINI5 ~BE IN5TALL~ IH. 5Ef'AAATE ~ 1-WNLII£ !UEB<E 412E ~ BE A. MINIMJI-t Of 111C.f (:llo:) 11-E OIA.I-1ETfR c:l' 11-E PIPE TO E1E ~-flllE HRE 'ft..EBIE!!5 ~ 11-tA.f HREfl ~NOT BaMD IN. f='IF'E. MllJIHJ.t ~ t=oR '5I..J::Yl:5 5tfi6J..1. EE ni:Nrr' FOlR ~ lt.t:..ti:S FOR~ LATERAL LIHE:5, 11f1Rt"r' ~) IN()Bi rOR. I~ VOL1' J1JLiiliN9 IN C01.1EXJI1 HID 1441R1Y fiiX (3b) I~ FOR f.I.,.EBIEt> 1-W'Nllt£ AND/{R ~L HRit-4 ALL LA 'JBt.I.L. Lit£ F'IP!Na ~ PAVEM:NT NOT fpLEEVJ:O, !iK"d..1. BE Pd:. 5GEDU..E 40 AND ~BE lt6TAU.f0 F'RIGR TO PAVIN5. Pl6 ~ 5~16HT NO 5IA""PCfU PIPE GOMT1r.tl01.61. YON BOTTOM.~ MOT BE P'R.!!! Of' R.oc.,.KS, ~$oR AN'r' StfAttP ceJec, 1$, $lt41C! PI..AST1C. ftlfl! Itt ~. MINIH.IH c.ovEFA6E FOR MAit.a..IHE SIZES I~* NO 5M.tti.ER IS E16tfTEEN (l&) l)l:,tte5, FOR SIZES ~" NO l..JrroR<5ER. GOVER.Ae:E IS ll"EWTY FOI.R Cl'\lltGtffS.. FOR l.AT!FAL. Llr.tf'5 Tl'ELVE 02) llt!E&. 1;;10 VOLT H~IIG IN CONI:UIT Tlflftn' ""J lt.Ufl ~ J.a-1 V~T~ ~ HIPJ! ll'B..VE (13) na£:5 HIWMI.t-1 OR. llE SAl-E DEPTlt A5 n£ MAINL.JlE DO 1.IOT INSTALL Am' PIFE CR HJRIN9 I:)IREI:jlLV OVER AlJO'TlER. BALL VALVES,.6A.1E VALVES, f<EVOTEc..GMl<'DI.. VALVE54EXC.B"TFOR: AWTI~F'ttOH.lYF'S NO (SI}Ic.tc: c.GU"J.S5 5ttAU. ElE IHSoTAl..LEP IN eB..OYi I5RAPE L.0C.KABt..E 'BOXES'' 1-WUA=Ac.l\REC:I e'( H-IE1BC: OR~ U5E RO'"' 60XE5 !'"OR MlE VALv!:, eAl..1. Vlad.V'ES HbcZII(,IC c,c:tJ:3~ AND Rf<,TA.~ E5o.>CS Fall~ CDI'TROL V~VB. VALvE &ox: LIDS~ BE IISRfE'N ca.ar:z. I-ABfi.,ED 0&./',"GN", ''GIC,0 aR. "R(,V" J-tl11-l C.ON~ 9TAT1oN .......... <f£1' VALVE BO>:E!& OHE (l} lt.t:;H ABOVE RlJISM I!IRADE, SET VH..VEfl AT Sl.f'FIGI&IT OEF'11-I TO F'ROVIDE AF'PIO'LlF'R.IATE ~ EIE'T1"EE)J Tt£ GOYER NO THE VALVE. INSTALL 1~6A.T10H. mJIPMEN.T 50 n£ VALVE SOXf5> FIT NrntOUT CAITTIK61HE t1AI..l5 OF n£ VALVE ~UITVALY'E BOJe ~ eE REF'I..AC..EP AT 1>10 C.OS.TTO ltfE~ TIE c.oNT'RJ!rGTOR ~ l.OGJa<JS ALL VAJ.Ye5 lr.J ~&AREAS,~ CJIR5C.'IED 0~$ f!J'flHf o.A.it. Jad..L 5of'RI~ tiEAD5o 5tfi6J..1. ee 5ET f"ERP!'HDic.ll..AR TQ FIHI5t-16R/IOE. lleTAU. ALL 5F'Rit«L.ER:S Ot.l RISERS Tl'£l.VE (l~ I~ At'tAY fROt.t I1AI..L5 NO STRU::.TUR.E5. ALL POP-UP l'l'f=E !JPR!t.KI.ER +EAD5 lt6T .All.E[) IN SHRLB AND~ AREAS SMALL Sl: lt.&TJ\I.l.ECJ 50 ntAT lHE TtP cF M 5of'Rit.IC:I..ER tiEAU I~~ 011r.t:Af ABOVE I=IH151f ......, ... ALL PClP-UPTYf'E 5PRJt.tCl.ER~ lt6TA1..LED IN TU<:F ~ !rtW.L BE IN5oT~ 50 'JKI\T 1le TOP OF THE SoPRIHJo::l..CR tiE/aD IS. FlJ.et-1 HllH AOJII£S.I.T PAVIH.6, APTER REC.eMN&lCI'IFt:.A.TIOl.l B'f 'THE O.AR.. 11-£ c.c::;t.tTRAC;TOR, HI'THilJ 1E1.1 (l~ OA'Y'5 ~ AD.J..QT N.1-l,.AH.I 1-EADt. 9o TWI<T THE TGP t:l' 11-£ !!IP'RI~ +EI'.D 19 ot.E CiiJARrfA. «.)I~ J>B0VE FINI5H 15RADE . INSTAIJ. AtJTI PAAIN Y~'>/e'S TQ la-IMIW..'TI!! J.c;H HfX;I PRAI~ lroNTI R?AIN v'AL-Vl!: CAM LHI-nf.'H*."'"l.m IE REI::IJRB:) C))l. ~ ~, Ail!OR TD IN!i'folrroi-I-A1'10N,.~TOR~~ ~Pt" HITHGIN SITE 15RADE51F ~IS AA£LEVAT10N CJI~OF ll1042) fEET OR mRE eET1'I:EN lHE Hk5tiE5T /ll>D L~T SoFRII-IC:l..ER t£.6D c;t.J A S'r'STCH. lr.&T/Il.L M ADV --· ~ ~\I"BBJ1 H:S-1> P.f(, ~ ~INE!i ANI:) F1111NS6 t-IUi1' fiiSGENE PRI~ BB"or:i!E '!d. VENT HB.DIN9. V. AD.JA1Ili8 ND 'I'E!lmM 'nE ftY'SI'&f AFTER PIPEUle ASS&iBI..YlliE GOMT~T~ ~ ~y R..1at 1ltE !11"5'&t. 1111H ~Eii-09AIJ.~~TJ!'$Tf1C:IR.I'c;UR.{4)~!o.TI:I0~.9.1. AFTER GOVEFA£5E NO f"'RE5c!iiJRE TE5nN51liE GON'l'RAGTOR SHo=\LL INSTALL ALL 'fERMI~ RX'TliRES AND f"'Bi!.F()RM A~ TEST. 1l1E COWTfUrrGTOR ~ AD.JJ5oT ALL Sf"RRm::L.BO: tEAOS fWD VALVES FOR OPTIHJM ~AIO TOf"REVENTC'VERSF'"RA'I", THIS.~ ING.U.OE TtiEU5E OFVAAJABI..E Nl!C, NOZZI..ES ('1/~ NO~ ~~111-~ 5GAEEN& ~. 1HE fiELE(;110l.l OF 1HE BE!&f DEc!lfil!:E OF~ TO FIT TIE 511E AHD ~we OF llE R..DN GONTROI.. AT EACA-1 VALYE TO RND 1ltE OPTlM.M Of'"EFA 11"6 ~ FOR EACH ~'IB-t. 11t!! etJnQ!! $'1"STI!!H ~Be M 1"Uk H.ITOM4I.Tt:. ~T1otl ~ 0He ~ N1 PAY$ ~Oft 1U' Allr' PI.AlmNIS. 1 ~ IAAIGA llON DETAILS ~================================================================================================~ Sprint~ 18200 VON KARMAN AVENUE, SUITE 100 IRVINE, CALIFORNIA 92612 ~PROJECT INFORMATION: SDJ4XC861D SDG&E STEEL POLE #Z718327 1926 SWAI..I.DW I.AHE CMLSBfD. CAUFORN~ 92009 SAN DIEGO COUNTY '=CURRENT ISSUE DATE: ~ 01-23-13 ~SSUED FORZONING II ~ REV DATE DESCRIPTION ,, -: ---BY : ---:-" J 01-23-IJ COMWENTS RU 2 05-02-12 SDG.tE REll.JNES ARC 1 03-29-12 10011 ZONING ARC 0 03-14-12 so. ma RlR ARC REVIEW ~PLANS PREPARED BY: MSA Arc:bltet:tun~~ cl: P.buuJJzw 3194 A1rport Loop Drl.,.., Suite C1 Costa Mesa. California 92626 ph 949.251.1177 ta IMU5LIIIO .... . 611ft Diego . San FranciiCD www.msa-CTJ.Com ~CONSULTANT: )epratti ")___.) --t3141 IWJI! IU!NO -.wM. Cllle1tJO '-· -~~DRAWN BY:---CHK.:--APV.:El ~ ARC I MJS I MJS I LICENSURE: ~'""' "''-'' ~ IRRIGAllON DETAILS SHEET NUMBER: REVISION: I L3 1~,1 OD (I) ~ SHRUB PLANTING L~..:.~ .. ==~IHl. "~,.:lf"~"""- 4.21~~THI.m ~~ .. .. ~~_, .... •. It!!'' .... -... --.--~ ....... ~--·~'""' .... ~~";t,- 2.~~,_ .. ..,.. ..... '"~ JJ. S"MUHJ.AYIR 4. fERI'IL.IZER T~ '·~~=~ ==-DONal" caACAt e.. MA~ Sdl.. sc:.AMPf • ._10" oR ~'JB}IIIJIICACFt~ 1. AA1M!_OR_...No'II!D ~IU. &.fiNIIH~ 4.~S~Det1f'.........-PII' IO.~~~~l!IIOR II.~'Jlbl SELF CLINGING VINE PLANTING P L A N T N 5 5 P E C 5. L- 11fe!SC P'Ft4-HitJ6$ ARC PI~T1C... 5tfOHN5 I~ I.OC.ATIQ»$ ANP R.l::t.AT10NSHIP$ ~ PlJroNTIN& ae-en9. Fl~ !NT£ (DhbiTIQQ, ~~ I:llJRIIG (..O»aTRI.tT10N. WAY R:fGI.IIR£ ~mmeLAYOUT. lltE IF¥!.16A.TIOH. 5'1"!11EM ~ ee R.lll Y Of"'!::li!AnOHPL., TES>TED fWD~~~ f"'RICR TO PJ...6HTII.t6, AN'r' 54&S>TI1VT1Qf>&t-!W~Tele ~ fl'( Tl-5 ~ ~1111:C..TOR QAR. ~QR TO RJ~ ANI:) IN!I1AU.J\1l0ll ll.fll.JI.'WMI\~~ ll1E c.oH'JRoo'GTGR ~ MAIKTAIN A Gt.llrd...IFI~ 5U"!:RVI~ FAMILIAft. NTH n£ 'TYf'£ OF riORJ( AND THE ~T CJ~ OK srre AT AlL 111-5 PI.Rit-6 IP6TAll.AT1oN W M ~ANP~HI«'r't-fAI~. ALL R..AHTMATERJAL 5K<=ri1..L ee 51JSJEG.T TO 1l£/>FPN7VPL eY TltE~5 AII'THORIZ!P ~A11ve t>A.tt). -n-E ~1'0R. ~ &.&fl1 A I-IS1' a= AVAII-ABIL11Y FOR.~ BOJ<ED ~ TltiRTY ~)DAYS SfTORE ~ R..AHTIN5 FOR ~AL AT n£ ~S'I"lltEOAA CDN.'IRI'G'roR 15 RE5PG!t61BL.E FOR ~5HIN5 PJ..IrroNT MA.l!RIAL f'REE OF f'E515 OR Dl51fASeS AND NORMAL IN FORM FOR n£ 5f'5::AE5 AtD c:e511:5W c.A1..1.EP f'OR IN 1l£ f"'...ANS, c»>L. '( A5 MANY Pl.ANTS A5 CAN BE A...ANT1:D AH:I ,.....'TERB) lHA.T SAl-£ DAY SMA1..L BE DISol'RiarTED IN A f'I..AHTIN5 AREA. 1HE C0N.'IRA()1"CR fiWrrd..L ~f INilfAL.L PJ..AN'f MA.'f!RI0'\1. 11-tAf lfl HJL'fEI).oR ~A D.AM'AQEI) ROOT BALL. COM'IRAG'Tl::lR 5HAL.L t.t:IT INMAL.L 1REE'5 HITlfiN '1'&1 (lO) f"':Ef OF ROTOR!&I D-AtG'T"I-EAD5 OR NITHIN l'lf<:!~ r.t) F"'i:CT GF So~ Sf'RA.'( l'fEAD6.. All TREE:5 111THIM A SF'ECIE:5 5HAU. HA.V'E M'ATGHINI!t FORM. SIZE AlD ~ D&ISITY. !iOIL AMENDMENT AWD BAGKFILL MIX AS Df'SGRIBED HBII'EIN ARE FOR BIDJ)IN6 ~ ONL. Y. ~C.IFIC. ~AI-D f'!:RTILIZER. YiiLL BE sa.e::,~ AHa ~IFIED AFTER. ~ efO'ADI~ IS c.oMf'I...ET': AIO 501l.5 SANPJ.J:5 cAN. IE T'!STEP. ,6,NS.D1-t:HT Al-P ~~li$'R. At-Q.Nr AHP n'ft; ~ ES !>$~IN M ~IC. f:OU-'5 REA>R<. IlL..._, ~'men' H:B:) AfiA1E'I-£N'f fMAL.L BEGM APtER. ~ QRADIUQ. CON 'tRAG fc:R. 1'0 IRRIQA1E R. ... U11Na ~FOR l1'tRa (3) I'EBCS OR. I..NTlL Sl.f'FIC.IetT I"EECJ ~Bn HAVE 15fRMI""""~· AF"JBit r+llc.t-1 A c.owrk.T~C.ICJE IS5PRA'I"'ED En' A UCS&I:D I"'!ST coH.lROl AFF'l..lc.A.TCR. IRRIBATlON 166fOFJI'B:) FGlR FORf'r"-EIQMf(4f'A +k:VR!5. mEDEAO ~ ~ ~ RB-fOVB:) AND AF'TER 50CM Tit-£ AS~ fG1R n£ I-EREIIGIOE TO 01551PAT'!, Pl..ANTIH8 MAY eB51N. w. so~ flliEP~'ni:IN t.r:1 SOIL F!iii9:PARA. TIOK 5Ho\L.L BE t:rONE LNTlL ROU!M1 6RADINe 1146 BB:N JI.S1Pfl!lO>If! BY' THE OAR, c.R:05eoft!PALL Fl.ANTII-6~ TO CJfT'TltOF TWfl.'Ve (l~ I...:.HE'S AWD I.WIF"'f&l.Y B1..END 'THE Fol.J,.DHWS A~ INTO 'THE TOP o&IK (b) ~ Aa PARr aF T1E A\JI~ GIV.clhJS """""· Ff8 1)fgJ5.6.Hp OQOQl SS?LIARE ffFT• n-t:)+IJNOREDC2:X))~ ~R..116· SIX (b) CA.IBIC. YAAD5 Nl~ 5TAEIILIZEP ~C. AMEHI:'M:NT 11-t) +IJNJ:Xa:> t2:X)) Pt::l.AV!t ASRJQJL~ ~ v . .....,~IM& l'tf~ RGIJett 6RADIN5, l't:ED ABA'TB'EWT AHa SOIL ~TIOK ALL PLAWTIN5 AREAS ~ eE Sl-fOO'Il-LY ~. TtE~ 5tio\ll BCUHI~N05NC:IOlttNTH t.o AeF<lJPT ~Q'-$UR.FAC,.I!:, e>R..APIH5 SAALL PROVIPI: FOR. NA'T1JRiaL ~ HITH.?VT lc:H $POTS, f!!Di LlttES $HAll D! AGC.I.RA.Tl.EV SET Elf llB'TRIMENT AT 11-t:)(:V PERI::.&ITMIKil-lMfii..DPE. c.oH.'IRk.TGR !7ttALL ~ FROM Fl.o6.NTII-6 A1<2A5 ALL t:lE&RIS. rt:ECJSo AI-D ~ ~ 11fAN OlE (I} IIIQ-II'N OI.At-£1'Bit FROM -n-E 1'0P fii,C (6) INQE'S a= fiOIL AN:) D~ OF OFF-SITE. ~. ReTAI..I.AT1CJM ll1E IRRI6A.TIOH. '5't'51EM !~HALL BE RILLY Of"'!:RA.nONAL, ne:5 lt-6TA1..LED NSD A~ 1E5T c.oH'I...ETECJ f"RROR TO ANY' GONTAJr.eR. OR l5oRti\IND c..GIVER. MATEftiAL IN5TA1..L.o'.TIGIN. EXJ:A.VATIOK FOR PL.AHTIN5 ~ lf>UI.CJ£ Ttff S~ILINB OF TGPSOIL f"'R£lM NTttiN ~p;~ee~VA'T'!:I:J~~~ ttt.es..PI.AliTPI~AI-P~Al..L EXCA.VA'IED R..AlmN9 Ha..E5 fiHALL !-fAYe \'ERTIGAL, ~FlED '61CES. THICE C2X) me 51<!E 01= THE PI~ AND SIX (6.} IHUe MIHIHI.N PECf'ER. ~ 1lfe R.001'BAU.. EXC.e6 fiOIL<ael8:RA.'IED F'PO-t'TME EXGA.VA.TIONSHO WOT ueeD A5flACA::1'tll OR IN E:5TAfli..ISHIN5 PIWAL I5RADE:!t 5HAU. EE fi!EMOYED f'ROM n£ !lllE. 1Nfi=EC,1' ~ HJD8fN'O-Y'l.Q)felOR WfAWI91£ Hol.'t"tEO RO~ OOWOf CRACK ROO'JBII.l..L RB='I...AGE H« PJ..ANT'S Hll-4 ROOTS c&IRDUNIS me ROO'I'BAl..L ll1E c.R:Orfl AREA. OF ~NO~~ BE2° HI~ PJF~ 5ETT1..1N6, 'Jl1o'riK ~~E!WT F'IWSI+ 6RAEJJ!. llfe ~ DACIC1'1W. FOR PJ..IIoNT Pl15 ~ COf.61&T OF 1le FOJ.J.MN5 I-11X. Pl,..oS.NT PIT'!!i !M4Ai.+ Be f'ILJ,.ED TO THe REaUIRB::I GIV.Cif Atlb ~'I' !ETTUD 8'1' »\T!R APPUC....TIGN AWD TA~t.ra. F!'R CJBV: )'ApQ QF HI X'· IIJIFQPHI,. F1 fHr<e? SIX (b) P~ B'f VOI...IJt-E OH.-511E SOIL tJf »ClN 5ALIWE, NOH. SGID"" l.OI'I 60fC'JGN CDH'IENT SAN7t' 'TEK'T1.IR!P TOP SOIL FOLR ('\1 PAAfS B'l' VOUME WI~ MABILI2ED ~G AMENOI-etf ll'EHTY (20) POI.tDS '\5RO·POVffR. R..ll5° n-£lln' (:laj 90LtbS looisRI~~ Ei'I"PSS.M ~IU.. PITti41.Fri'<t' 11"f:1J Pl.k.B ·~" 5EV'E:N rtJ e;R.A.t-1 OR ",&,e;RIFOPJ-!"' 1J"e'NT'r' Ole (~I) eRAW SLDH RB..EASE R..ANT!Na TABLETS fiPREAD EVEN!. Y AROIJ.D ROOTBALL. 1lE ~OF TAfii..ETS FER. R..ANr 5ttAU. EE f"ER n£ MNtlf'AGTl.IRfR. PR.CNICJE A~ ri6.TER. at.siN ~ NDE As 1lfE ROOT BALL FOR. E.4Uf f'I..ANT. r+!\~ ~N~Y'. LNTE Vltff5 AND~ ALL SoTAf:ES AND 'TRB..LISES 'Tl-eJ ~LY PASo~ AND ~IN A6AIN5T t+\6<1'EVeR STRLt'TURE NeXT TO N-lt::.tJ 11E'r" ARE Pl.AN'IED. 1R:E5 r-usT e6 STAICED AHI7/0R Ei.I'I"':D AT TtE Tl~ OF F1.1aM'II-5, I-AT f£JI:) H1+-11N 11-t) (a) DA'I'YI OF Ofi.JVER'I" AWO 00 WDf flfORE IN H!)1' f.C.N. 6E'f IN ... !ITABeERB) PATTERN CN PRE-IRRIBATED l-OST <!IROUO NO SET FIRH..Y ~IN5T 01'1-eR. 500REC.E:5. tYI.~~'fAF"JBitR..AWTIN5. LN..e$6 ton::'Q ~$1;?,. c.otmtAc:.WR. $tfA1J. f'l...4NT ~ ~ IN $1AAIGHT ~ ~'( fPI<.,ED IN A~~ 9A.T1SN AT 11-E DnfRVN,..& L19TED 1\J 11-E DRAH'NISB. AF1!:R AU lq..A1.111~ I~ c.c:t-fPI.f1'B:), 1'00 ~ ~ L~ AR£Aa El(CUA:)IWS 1'LRF. HI'$ A 2• LA~DF o&INQfEJRIIC ~ ~ ~(,1-l nfl~ 1-A'I'Kifa 1\J AaDITION. TO &:::l~L ~ MA.~AL5. LN...&eS$ PIP'J!t;.~C71'1-HH$1!!! &t'T1¥QAR., ~ O~t'TQ PJ!t-tCN'I! ~oR eRoKE!N BRANCI-ESAN:) ~ ~ . .... _. c,.ot.l~~ $KAU, ~P! A NIN!n" ftlaJ PA'( 6UARAN'Til!! F'OR /loU. PI..'<NTS ltXCUbll~ lRfE'S I'+IIGH :5H-tll..L BE~ FOR. Gt£ (l) RILL YEAR. CUR.IWl> nE ~ F'ERJOO ll1E c.oN.'TRt'G.TOR: ~ REf'I...A!.e, IN A 111-El.Y MANNER.,~ R..AKTS 'Jli4oT ARE LN-EALlH't", 1-'11551~ OR. PEAD. lHIS alla.RAUTCE StfAU. NoT I~ PA~ TO~ C.I7V1:::R I"RRM EXC.e551VE RA.IH. Rlt~FF AND~ NIHDS. 5LtA+ "NATURAL.' DAl-1.66E 5tflaJ..1. EE REPAJRED !=OR nr-e NO 1-\Ao.TERL'tS. ... ~ c.oN.'IRI'GTOR: ~ IHC.UDE IN ll'EIR eiP FOR A qo CJA.Yl¥\IWTENA»::C PERIOD~ Fl""'-1. lAHDSc.Af'E k.CEPTAM::.C En' TtE ~ llfiS MAINTE'Wr~N::C StfAU. IIJ:L.JJI:lE. B.IT IS I-JOT 1..11-trT'JP TQ, ~IN6 ~ .A<F$.1-0 r&ieJ) ~. li-'~. F'I!;T Ai¢:1 PI~ I=Fi$15 .lroNP ANY' Ol'+ER. N:)RI( ~FOR +fEAL 11n", VI~ R.AN.1 QROH1I.I AWE>~ GENERAL N 0 T E 5 A. 'Tli: l..AHD5c.Af'E A.Ra-IITEC.T rillL INTER.PET TtiE 1-EAH!lts OF ANt' PART OF lHE f'I..AH5 AND ~lfSICAllON$ .4S<::UT HHic.H AN'( 1-ft~TiroNPft..IE> ~y Attl~ ANP I-ll$ !;tti$1QN HU.L DJ! FINAL. a, 11-t! C.ONmA(..~ ~ CJ8TAIIJ. C.I-Attlfl'lc,.AT10W. TO GO!!f.TICN8 t:Ua-AT1....aE TO~ ~INS ~ !SLBMif11WQ A BIO. c;.. n-tli COMTR.6Grc:R. ~ ~Pe ALL l.AeOR. HAITE'RIAL5. EGUI~ AHC:Il.AeOR. ~TO c.Q-IP~ T1fE J"DRK ~ QN 11-t! PRAH~ P. n£ COK'JRI.GTtR~ ~ ~CALIR?RHIA'STATEC.ClNl'RA.C..TORS Llc.eeE OR c..eRnFic.ATC 1=0R T"'"F'e 01= ~ LIST15l:J, 5LtM f.6 c.-ZT. E. n£ C.OK~ roFt SHALL~ ALL ~y OOl-PENSATION AND LIABILITY I~ TO c.o.-ER ttl5 ~AND~ TO RILLY ~T nE o.r+eR FROH ANY P05SIBLE 5UIT OR. LSN. fl. 'Tli: CON~ TGR !7ttAU. MAINTAIN A GUiaLIFIEP sc.t"'!RV150R.. F#IILIAA NTti 'Tli: n'F'E OF HofU;:: Ale' life' C.OW'ft:V<GT PQCUI·ttW:I"$.. ott $rn! AT~ TIH:!S Plftlll& IN$T,IrU..AT1oN QP 1HI!' H:::lRK A\.ID PRJt-tMl'l't-ti\IN'l'E'IW-tf. •• 11-1!! C.ONmA(..~~ F'ROYIDI! ~ ~'( ~IT!l. A).lo L~ AND A-SeUSU!! ,..,.T ~ H:>Rk: 1'0 fiE R'RFORt-£D H:E'fS OR EJ((.EED!I ALL APPLICABLE cor;es JrroND OR:DINAN::,Efl OF FRIVATE OR ~AL ~IES AAVII>t& .J.,RifOIGTIOll avER TIE PRO..B;.T. M. IT IS 11-£ ~BILITY OF 'RfE GOliJlVrrGTOR TO FAMILIAR12E l-llt-t!!if!,.F HI'JH ~ QR..f\0£ DI~E:5. LOCATION OF Y+\U.S. RETAIKIU!e t¥11..1.5, '5naG11RE5 NO unLmE:5. lltE c.GIKTRJoG TOR '!7ttAI..L REF'AJR OR RB"'...'GE ALL nEMS ~ B'l" HIS Y'ORK AT KO El<J"B6E TOnE Ol'ICR. HE 5HAU. GOORDI""'-'IE tfiS noRS:. NTH C7Tlti:R ~TCRS FOR. n£ I..OC..ATIQN ANP IHST.'-U.AnON OP' PIPE! ~,lloNp L.A'T!'ft.lloL 1..~ ~ I"W.L$..1Rl!'R. IQOAI:)H,I,"''S,. ~:'~RIVES HC 9A.VINS, etC. 11-£ C.ON~TGR~ UJM: CNLY ~HA~I~ aF ~ A).lo n'l'=8 !MW::w.I.AtD ~BED I'N 11-ESE [)R,Irr,HJt.dfl. .1. n£ COK'JRo6G TGIR '!7ttAI..L El<ER.CriSE ~ IN !141HDUN5, L.OADINIS,. UNLOADIN5/WD 5TORIN5 ALL tcotJI~ AND HJI<TERIAI..S. ALL 1-\.!at.lERI/rt..S At.0 15GUI~ 'JH4.T IS CJAH/IoeB:) riLL Elf. DI$C.~. ~If ltJii>T~. ~ ~ el!! Rlef'Aif¥1::1 C'R 9JfPJ.IroUP AT 11-¥ Dlsc.Rel'IQN OFn£~'5 ""''JloiORIZED R.EF'F'E5SITA11VE fOAtt) ATWO ~TOTE~ 1C. 11-E CC)NTRA(.Tt:R. ~ PRD11:G1' ~ PJ,.ANT'INIS ~ FR.CJM' E~IVE CC)~T10N ~ TJW:::.t:lt.la MA.~IALSANDEQJIPMENTTOHO Hll-41N 11fE 511E 1.. n£ C.OM'TRAC..T(:R$Kirroi..J,. 6e ~BJ.efc;JR~ nt:F'T$QR PHV'I5e TO M""~IAJ,.$ ~ DB..JVERED fO .J::IB SI1E. M. TH:!COHTR..6Gra:tWL.lse!~Dl..I!PC'RCOORDI~nOH.~~TOR$ A4 ~U~ TO A(,CDMPLiiY-1 ~ (..GN!IT1:U.t.TIOU DPf'IV..TI~ ~ R9~, C::.Qije~JIT1 fll..EBIE!S. E1V. fJM4.l.L fiE IN PL.A(iE FRICR fO IKflfAllAflON OF Cc:'N!ITRJVTlON I'TEI-1!& . M. AU 9RD6'RE!K 1NiPfC.T10Na ~BE (.DMFII...ETB:: Befc::RE ~It&~ 19 !iT~. A}ff HCRt::. GOV'ERB:) UP eB""GGRE REQJIR!ED IJ.I!iPEC.TICt6 AR£ CGIMR..ETED HILL BE EJ(pOfa) FOR REVIEH AT l1E GOlJT'RAC.oTOR'fl El<PEN&E. 0. GlEAN-UP 5HALL ee [)Ot£ AS EACH PORTION OF T+£ Jo'U>RK ~ REf'll!iE AND ~DIRT"~ BE~ FROM 1ltE SITE. ALL t'¥1l.IG AHa PAV1'6 5Ho\L.L flE eRa~ AtO AN'I" ~ OCQ..RRIK6 TO Ttff ~OF O'TlffiG 5ttH..L BE REPAJRED TO ORI61N1aol.. COHPITia.J, P. F<EFBO: TOnE ~IFIG.A.TIOt6 FOR ADDITIQNolrll. t:eTAJI..fD ~llON. G. 'Tli: COMTRo6GTCR'5rtoU~ BE F\A..Lt' al/loRAtJ'TEED FOR QE 0) FW.L "''C,A.R FROt-ITHE PA11! QF N;a.PT~ 6'1" liE Q~. N.f'f PEP"et;T~ M""~AJ.$ QR FQOR HJPJQ-fANSHIP SMA1..L BE REPI...ACB) OR Cc:'R.R.ECo1'ED Af" t.t) Gc::&f fO f+E a-osL R. 1H...E'517NO'I'EJ ~5E All STRLtl\IRAL I~ &tfi6J..1. fE IH5TAl..l.EPf'RIOR. TO IRRI6ATIQ.I ANP PJ..ANTIH6 oA:AAnQNS, ~ IH. 11£ GA!SE .....eRE BC1'RA HQRK OR. GAAlJQES H~ ~~fIN ANY' INCREAf!EO COflfflo OYER. 1l£ CONTRAGf ~ 1Wf (..GIN1'RA(;f0R ~ FIRSf ~IV£ f+E Ol-n8:R.'fl EKFR.E!JiaED l'tRI~ Af1F1RDVAL fG1R ~CA-4 ADDITIG~No=\1. R.tD5 PRIOR. n:> ~IN8 M'ATERIAL5 OR. DOINSnE~. 1 ~ PLANTING DETAILS ~================================================================================================~ Sprint~ 18200 VON KARMAN AVENUE. SUITE 100 IRVINE, CALIFORNIA 92612 ~PROJECT INFORMATION: SDJ4XC861D SDG&E STEEL POLE #Z718327 1926 SWAI.I.DW I.AHE CMLSBfD. CAUFORN~ 92009 SAN DIEGO COUNTY '=CURRENT ISSUE DATE: ~ 01-23-13 II niSSUED FOR: UREV -DATE ~~~~I:ION __ J ,, .. -: ---: ---:- J 01-23-IJ COMWENTS RU 2 05-02-12 SDG.tE REll.JNES ARC 1 03-29-12 10011 ZONING ARC 0 03-14-12 so. ma RlR ARC REVIEW ~PLANS PREPARED BY: MSA Arc:bltet:tun~~ cl: P.buuJJzw 3194 Alrport Loop Drl.,.., Suite Cl Costo Mesa, California 92626 ph 949.251.1177 ta IMU5LIIIO .... . 611ft Diego . San FranciiCD www.msa-CTJ.Com ~CONSULTANT: )epratti ")___.) --t3141 IWJI! IU!NO -.wM. Cllle1tJO '-· -~~DRAWN BY:---CHK.:--APV.:El ~ ARC I MJS I MJS I LICENSURE: ~'"m ~:NG DET~LS SHEET NUMBER: REVISION: I L4 1~,1 CUP12-13/SUP12-02 SDG&E Steel Pole February, 26, 2013 City of Carlsbad Planning Department Att: Greg Fisher 1635 Faraday Avenue Carlsbad, CA 92008 RE: CUP12-13/SUP12-02 SDG&E Steel Pole SUBJECT: Response to Planning Issues Attachment A This letter provides additional information responding to the City Planning Departments concerns about the location of the proposed site. Sprint has worked with the City Planning Department in finding a preferred site that would meet the coverage objectives for Sprint as well as integrate with its surroundings. Sprint request that the City move forward in scheduling the subject property for Planning Commission due to the lack of viability, lack of adequate coverage, and uninterested owners. The site selection process included the review of the commercial property located within the Bressi Development project, the new housing project located on the east side of El Camino Real at its intersection with Cassia Road, the property just north of the new residential development at Cassia Road, the ROW Light Pole on El Camino Real, the existing SDG&E steel tower located near the northwest comer of Poinsettia and its intersection with El Camino Real and thesubject property as well as the intersection of El Camino Real and Alga road. Site Candidate 1-Commercial Property at Bressi Ranch This property was reviewed for its ability to cover the new Bressi Ranch Development as well as the valley floor to the south of this mesa. The property had good propagation on the mesa and moderate propagation in the valley and El Camino Real. This site was not chosen as a viable candidate as there were no plans at the time of review for any commercial development within this footprint. Sprint determined that it was not plausible to design a new vertical element within this area without any understanding ofthe future design and footprint to be utilized within this commercial area. Site Candidate 2-6250 El Camino Real 1 This property is roughly one mile north of the coverage area and is a medical park consisting of a two story building. Due to the distance to the coverage area and the low rooftop elevation this location would have significant shadowing by the grade to the south on El Camino towards both Poinsettia Lane and the golf course. Another site wo"uld also be needed to meet the coverage objective Site Candidate 3-6286 El Camino Real Also roughly one mile north of the coverage area and is a pre school consisting of a single story building with a small tower on the NW corner. Due to the distance to the coverage area and the low rooftop elevation this location would have significant shadowing by the grade to the south on El Camino towards both Poinsettia Lane and the golf course. Another site would also be needed to meet the coverage objective CUP12-13/SUP12-02 SDG&E Steel Pole 2 Site Candidate 4-6210 Cassia Road This animal hospital location is'% of a mile from the coverage area and due to the elevation change along south El Camino Real there would also be significant shadowing by the ridge along Poinsettia Lane. Another site would also be needed to meet the coverage objective. Site Candidate 5-6220 Cassia Road This property across the street from Candidate 4 is a professional building located'% of a mile from the coverage area and due to the elevation change along south El Camino Real there would also be significant shadowing by the ridge along Poinsettia Lane. Another site. would also be needed to meet the coverage objective. Site Candidate 6-998 El Camino Real This property is located next door to an existing Sprint site SD03XC153 as shown on the provide map. This location is too far south to provide any coverage near Swallow lane or Poinsettia Lane. The proposed site is needed at Swallow lane with the existing site. Site Candidate 7-SDG&E Steel Tower at northwest comer of El Camino Real and Poinsettia This potential site had good coverage along El Camino Real and the Bressi Development but the coverage in the valley to the south of the Bressi Development was poor. Additionally, the new residential development under construction at the time of review seemed to create an access and location issue relative to the residential development. This site was not pursued Candidate 8-Subject property This site was reviewed for its ability to provide adequate coverage across the Bressi Ranch Development, the valley south of the Bressi Ranch Development and along El Camino Real. Because of the ability to gain a greater height on the steel tower as opposed to all of the other candidates except Candidate 4 this site is superior in its ability to provide the coverage necessary. This site is a discouraged site but this type of site is discouraged because ofits proximity to residential uses. The landlord for this site is both SDG&E and the Home Owner's Association for the adjacent condominium project. The project was notified and voted by proxy overwhelmingly to lease space to Sprint/Nextel for the proposed project thereby negating the main reason these types of installations are discouraged. The antennas will be strapped to the existing steel tower and the radio and power equipment will be located within a proposed equipment shelter designed to match the architecture and color of the adjacent condominium building. Additionally, there are mature bushes adjacent to the proposed location of the shelter, which will provide ample screening along with the additional proposed new landscaping and vines. CUPlZ-13/SUPlZ-02 SDG&E Steel Pole Right Of Way (ROW) Light Standards Sprint could not locate in the ROW on El Camino Real because it would not provide Sprints coverage objective. Sprint is pro'viding coverage to the north, east, and south. The proposed location is on a hillside on an existing tower that allows Sprint to provide coverage on the north and south side of the hill. The ROW site is located at the bottom of the hill and it would not allow Sprint to provide coverage to the northern area. The project proposes to mount 6 antennas onto an SDG&E steel pole and the antennas are painted to match the steel pole. The antennas do not protrude but hug the pole as close as possible and integrates with the pole making look as if it is a part of the steel pole. The antennas are mounted at a height from top of antenna 50 feet. The antennas are mounted at this height to meet the RF's calculations of clearance from solid interference and the FCC standards. The building located to the north at approximately 33 feet has to be taken into consideration and based of the RF calculation the lowest antenna must be located at a height of 40 feet. The hinges on the panel antennas will not be fully extended because if they were the radio frequencies of the antennas would shoot to the ground. The antennas can not mount to the pole directly based on the requirements of SDG&E. The antennas must be mounted to a steel plate and pipe mounting the antenna 4 inches away from the pole. The antennas would not extend more than l foot from the face of the pole. Sprint request that the City of Carlsbad Planning Department can support this project. Sprint has spent more than three month pursuing the preferred site recommended by the City and was not successful in finding an interested owner. Sprint request that the project move forward and be scheduled for the first Planning Commission meeting in April or earlier. Please consider our request. Thank You, Tim Henion DePratti, Inc. Site Acquisition/Zoning 3